"State","Facility Name","Facility ID","Unit ID","Associated Stacks","Date","Operating Time Count","Sum of the Operating Time","Gross Load (MWh)","Steam Load (1000 lb)","SO2 Mass (short tons)","SO2 Rate (lbs/mmBtu)","CO2 Mass (short tons)","CO2 Rate (short tons/mmBtu)","NOx Mass (short tons)","NOx Rate (lbs/mmBtu)","Heat Input (mmBtu)","Primary Fuel Type","Secondary Fuel Type","Unit Type","SO2 Controls","NOx Controls","PM Controls","Hg Controls","Program Code" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-01",20,18.25,3877.57,,0.008,0.001,1569.902,0.1204,0.152,0.0132,27921.154,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-02",24,24,5758,,0.012,0.001,2305.608,0.0566,0.168,0.0082,41005.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-03",21,19.55,4825.92,,0.01,0.001,1920.788,0.0678,0.171,0.0234,34161.659,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-04",19,17.6,4043.38,,0.009,0.001,1630.006,0.0666,0.157,0.0213,28989.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-05",18,17.12,3981.4,,0.009,0.001,1600.805,0.0619,0.153,0.0193,28470.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-06",21,19.54,4809.97,,0.01,0.001,1915.291,0.067,0.166,0.0212,34063.766,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-07",20,18.55,4026.44,,0.009,0.001,1633.995,0.0657,0.148,0.0205,29060.187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-08",19,17.67,3838.06,,0.008,0.001,1558.9,0.0643,0.154,0.0195,27725.797,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-09",19,17.67,4082.85,,0.009,0.001,1641.702,0.0654,0.147,0.0197,29198.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-10",19,18.3,4573.45,,0.01,0.001,1812.706,0.0587,0.164,0.0144,32239.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-11",19,17.55,3229.31,,0.007,0.001,1353.492,0.0653,0.132,0.022,24071.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-12",19,17.55,3769.93,,0.008,0.001,1537.801,0.0681,0.147,0.0235,27349.107,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-13",17,14.11,3176.8,,0.007,0.001,1278.197,0.0761,0.149,0.0346,22733.343,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-14",20,18.57,4388.93,,0.009,0.001,1749.591,0.064,0.155,0.0193,31117.124,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-15",19,17.28,3949.53,,0.008,0.0009,1584.49,0.2323,0.152,0.0133,28180.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-16",24,24,5376,,0.012,0.001,2156.808,0.0575,0.153,0.008,38358.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-17",21,19.3,4377.7,,0.009,0.001,1763.306,0.104,0.181,0.0139,31360.125,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-18",24,24,5592,,0.012,0.001,2224.008,0.0568,0.159,0.008,39553.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-19",1,0.28,31.64,,0,0.001,14.2,0.056,0.007,0.053,252.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-20",20,19.72,4622.8,,0.01,0.001,1843.603,0.0607,0.175,0.0181,32789.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-21",24,24,5292,,0.011,0.001,2116.992,0.0568,0.152,0.0081,37651.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-22",10,8.5,1900.3,,0.004,0.001,763.903,0.0732,0.089,0.0322,13586.116,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-23",18,17.4,4081.16,,0.009,0.001,1626.692,0.0591,0.155,0.0123,28931.518,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-24",20,18.54,4338.7,,0.009,0.001,1733.397,0.0654,0.154,0.0197,30828.954,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-25",24,24,5623,,0.012,0.001,2248.896,0.0572,0.161,0.0081,39996.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-26",19,17.86,3874.52,,0.008,0.001,1575.591,0.0606,0.138,0.0162,28022.412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-27",18,16.57,3330.38,,0.007,0.001,1372.692,0.0655,0.132,0.0213,24413.605,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-28",18,17.09,3634.05,,0.008,0.001,1486.3,0.0619,0.142,0.0144,26434.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-29",21,19.28,4648.05,,0.01,0.001,1850.301,0.116,0.179,0.0128,32908.217,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-30",24,24,5652,,0.012,0.001,2246.688,0.0567,0.162,0.0081,39957.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-01-31",24,24,5676,,0.012,0.001,2263.608,0.0568,0.161,0.008,40257.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-01",19,17.9,4384.9,,0.009,0.001,1745.894,0.0619,0.151,0.0167,30999.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-02",24,24,5645,,0.012,0.001,2249.904,0.0566,0.161,0.0081,39948.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-03",24,24,5935,,0.013,0.001,2353.488,0.0565,0.167,0.008,41788.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-04",24,24,6073,,0.013,0.001,2395.392,0.0565,0.171,0.008,42532.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-05",20,18.53,4618.6,,0.01,0.001,1828.893,0.1233,0.162,0.0108,32474.478,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-06",19,17.28,4004.17,,0.009,0.001,1595.601,0.1346,0.148,0.0129,28358.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-07",24,24,5505,,0.012,0.001,2208.696,0.0578,0.159,0.0081,39217.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-08",20,17.83,4086.22,,0.009,0.001,1631.998,1.9665,0.158,0.0208,28976.914,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-09",21,20.43,4794.33,,0.01,0.001,1906.507,0.06,0.159,0.0158,33850.97,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-10",24,24,5780,,0.012,0.001,2283.408,0.0566,0.163,0.008,40543.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-11",20,19.22,4486.2,,0.01,0.001,1784.904,0.0614,0.169,0.0146,31693.187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-12",24,24,5719,,0.012,0.001,2272.488,0.0573,0.163,0.0081,40349.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-13",24,24,5887,,0.012,0.001,2334.504,0.0565,0.166,0.008,41451.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-14",22,20.6,4964.6,,0.01,0.001,1967.898,0.0631,0.171,0.0178,34941.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-15",24,24,5642,,0.012,0.001,2248.488,0.0574,0.162,0.0081,39924.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-16",19,18.33,4177.67,,0.009,0.001,1667.204,0.0588,0.167,0.0149,29602.355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-17",24,24,5540,,0.012,0.001,2214.696,0.0571,0.158,0.008,39325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-18",24,24,5411,,0.012,0.001,2170.488,0.0573,0.155,0.008,38538.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-19",24,24,5967,,0.013,0.001,2363.904,0.0568,0.169,0.008,41973.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-20",24,24,5416,,0.012,0.001,2184.288,0.0576,0.156,0.0081,38785.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-21",24,24,6044,,0.013,0.001,2383.104,0.0565,0.169,0.008,42313.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-22",21,19.8,4400.29,,0.009,0.001,1777.505,0.0615,0.153,0.0174,31560.929,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-23",20,18.85,4130.98,,0.009,0.001,1668.998,0.0613,0.151,0.018,29635.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-24",24,24,5868,,0.012,0.001,2335.2,0.0565,0.166,0.008,41463,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-25",24,24,5766,,0.012,0.001,2291.592,0.0568,0.165,0.0081,40688.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-26",24,24,5420,,0.012,0.001,2164.8,0.0575,0.157,0.0082,38439,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-27",24,24,5736,,0.012,0.001,2275.8,0.0571,0.163,0.0081,40409.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-28",24,24,5360,,0.011,0.001,2151.096,0.0568,0.153,0.008,38194.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-02-29",20,18.84,4166.22,,0.009,0.001,1680.189,0.0606,0.144,0.0166,29834.544,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-01",19,17.83,4292.45,,0.009,0.001,1721.7,0.0617,0.149,0.0173,30319.412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-02",24,24,5442,,0.012,0.001,2185.296,0.058,0.155,0.0081,38483.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-03",24,24,6024,,0.013,0.001,2382.408,0.0572,0.168,0.008,41954.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-04",24,24,5644,,0.012,0.001,2253.792,0.0574,0.159,0.008,39689.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-05",19,17.49,4343.54,,0.009,0.001,1729.393,0.0684,0.155,0.0203,30455.093,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-06",24,24,5620,,0.012,0.001,2260.104,0.0578,0.16,0.008,39801.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-07",24,24,6035,,0.013,0.001,2405.688,0.057,0.169,0.008,42365.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-08",22,20.57,4965.85,,0.011,0.001,1995.886,0.0725,0.184,0.0157,35148.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-09",24,24,5960,,0.013,0.001,2373,0.0571,0.167,0.008,41789.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-10",24,24,5650,,0.012,0.001,2260.704,0.0584,0.159,0.008,39811.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-11",24,24,5949,,0.013,0.001,2371.608,0.0571,0.169,0.0081,41765.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-12",24,24,6129,,0.013,0.001,2425.992,0.0568,0.174,0.0081,42722.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-13",24,24,6079,,0.013,0.001,2402.208,0.0568,0.17,0.008,42303.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-14",23,22.21,5386.95,,0.011,0.001,2174.603,0.0593,0.198,0.0143,38294.609,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-15",24,24,5907,,0.012,0.001,2350.488,0.057,0.167,0.0081,41393.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-16",24,24,5969,,0.013,0.001,2368.992,0.0577,0.168,0.0081,41718.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-17",24,24,5562,,0.012,0.001,2232.096,0.0578,0.157,0.008,39308.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-18",19,16.65,3937.16,,0.008,0.001,1575.206,0.0941,0.147,0.0301,27739.411,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-19",24,24,5604,,0.012,0.001,2251.896,0.0576,0.159,0.008,39656.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-20",20,18.83,4353.47,,0.009,0.001,1755.106,0.0621,0.148,0.0166,30907.618,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-21",19,17.58,4270,,0.009,0.001,1714.102,0.0664,0.148,0.0202,30185.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-22",21,19.81,4783.78,,0.01,0.001,1915.192,0.0618,0.16,0.0158,33726.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-23",18,13.86,2877.73,,0.006,0.001,1176.395,0.1309,0.139,0.0456,20715.807,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-24",19,17.56,3969.01,,0.008,0.001,1598.504,0.0669,0.144,0.0203,28151.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-25",24,24,5208,,0.011,0.001,2105.904,0.0576,0.148,0.008,37086,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-26",22,20.7,4612.92,,0.01,0.001,1865.898,0.062,0.158,0.0167,32859.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-27",24,24,5750,,0.012,0.001,2298.792,0.0571,0.162,0.008,40483.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-28",24,23.17,5689.01,,0.012,0.001,2279.302,0.0622,0.165,0.0118,40139.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-29",9,8.17,1671.46,,0.004,0.001,700.601,0.0679,0.117,0.0377,12338.609,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-30",23,22.3,5016.7,,0.011,0.001,2022.588,0.0618,0.17,0.0154,35619.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-03-31",24,24,5081,,0.011,0.001,2069.592,0.0575,0.146,0.008,36447.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-01",24,24,5226,,0.011,0.001,2129.496,0.0577,0.15,0.008,37577.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-02",24,24,5283,,0.011,0.001,2138.592,0.0576,0.151,0.008,37738.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-03",24,23.22,4775.58,,0.01,0.001,1962.601,0.0602,0.143,0.0102,34632.552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-10",9,8.17,1810.57,,0.004,0.001,730.897,0.0848,0.087,0.0336,12898.186,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-11",24,24,5651,,0.012,0.001,2260.296,0.0574,0.16,0.008,39886.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-12",24,24,5422,,0.012,0.001,2179.608,0.0586,0.154,0.008,38461.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-13",24,24,4776,,0.01,0.001,1959.096,0.0583,0.139,0.0081,34571.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-14",24,24,4884,,0.011,0.001,2001.096,0.0593,0.142,0.008,35312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-15",21,19.8,4064.24,,0.009,0.001,1666.902,0.0638,0.142,0.015,29413.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-16",24,24,5640,,0.012,0.001,2249.808,0.0573,0.16,0.008,39699.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-17",24,24,5903,,0.012,0.001,2350.008,0.0571,0.166,0.008,41468.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-18",11,9.68,1919.3,,0.004,0.001,799.403,0.0709,0.081,0.025,14106.454,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-19",10,9.18,1778.96,,0.004,0.001,733.096,0.0656,0.056,0.014,12936.958,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-20",21,20.03,4256.12,,0.009,0.001,1747.897,0.0657,0.166,0.019,30843.783,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-22",19,18.67,3485.67,,0.008,0.001,1459.303,0.0636,0.143,0.0157,25750.056,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-23",24,24,5066,,0.011,0.001,2056.896,0.058,0.145,0.008,36295.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-24",22,22,4576,,0.01,0.001,1844.788,0.0575,0.139,0.0085,32553.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-25",10,9.55,2206.85,,0.005,0.001,897.003,0.0644,0.093,0.0207,15829.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-26",11,8.87,1865.54,,0.004,0.001,766.9,0.0847,0.081,0.0344,13533.545,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-27",18,16.6,2925.78,,0.007,0.001,1247.805,0.0638,0.107,0.0173,22019.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-28",19,18.11,3982.06,,0.009,0.001,1620.102,0.0623,0.148,0.0162,28588.821,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-04-30",20,19,3047,,0.007,0.001,1333.306,0.0615,0.14,0.018,23528.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-02",10,9.63,1905.97,,0.004,0.001,795.197,0.0646,0.087,0.022,14022.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-03",10,9.17,1463.54,,0.003,0.001,634.399,0.0637,0.05,0.0153,11187.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-04",10,9.75,2208.5,,0.005,0.001,900.1,0.0625,0.095,0.0203,15873.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-05",24,24,5798,,0.012,0.001,2308.104,0.057,0.164,0.008,40701.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-06",23,22.15,4114.35,,0.009,0.001,1715.495,0.0626,0.125,0.012,30251.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-07",15,12.95,2451.64,,0.005,0.001,1009.102,0.072,0.113,0.0265,17795.654,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-08",10,9.43,2246.75,,0.005,0.001,902.696,0.0654,0.081,0.0196,15918.639,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-09",20,18.65,4334.09,,0.009,0.001,1734.096,0.0646,0.142,0.0151,30579.607,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-10",20,17.9,3523.07,,0.008,0.001,1450.204,0.066,0.124,0.0166,25574.244,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-11",22,20.87,4839.43,,0.01,0.001,1935.088,0.0613,0.154,0.0131,34124.194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-12",17,14.83,3099.39,,0.007,0.001,1258.399,0.0734,0.126,0.0268,22190.927,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-13",20,17.68,3385.9,,0.007,0.001,1394.898,0.0681,0.122,0.0201,24597.352,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-14",20,18.05,4077.36,,0.009,0.001,1649.101,0.0665,0.152,0.0206,29081.328,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-15",24,23.2,5075.4,,0.011,0.001,2061.598,0.0615,0.151,0.0103,36355.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-17",3,2.38,246.18,,0.001,0.001,134.601,0.08,0.086,0.1097,2374.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-18",24,24,4053,,0.009,0.001,1728.696,0.0573,0.124,0.0082,30485.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-19",24,24,3777,,0.009,0.001,1632.192,0.0574,0.119,0.0083,28783.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-20",24,23.22,3822.6,,0.009,0.001,1641.491,0.0595,0.124,0.0104,28946.532,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-21",19,16.9,3018.92,,0.007,0.001,1272.401,0.0671,0.122,0.0224,22438.03,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-22",22,20.59,3727.9,,0.008,0.001,1563.893,0.0631,0.127,0.0146,27578.544,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-23",18,16.27,2789.66,,0.006,0.001,1184.896,0.0647,0.115,0.0193,20894.722,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-24",18,17.38,3465.98,,0.008,0.001,1428.497,0.0625,0.119,0.0152,25190.89,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-25",16,14.5,3463.05,,0.007,0.001,1384.199,0.0721,0.115,0.0195,24408.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-26",24,24,5554,,0.012,0.001,2206.608,0.0574,0.157,0.0081,38911.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-27",23,22.98,5054.52,,0.011,0.001,2032.191,0.0583,0.152,0.0085,35836.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-28",20,19.3,4174.6,,0.009,0.001,1669.604,0.0635,0.123,0.0103,29441.53,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-29",19,16.1,3211.84,,0.007,0.001,1309.494,0.0735,0.125,0.0247,23092.882,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-30",23,22.23,4817.94,,0.01,0.001,1948.104,0.0608,0.143,0.0103,34353.045,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-05-31",18,16.6,2885.65,,0.006,0.001,1228.499,0.0643,0.109,0.0177,21663.274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-01",16,15.13,3577.3,,0.008,0.001,1419.693,0.0814,0.133,0.0146,25018.664,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-02",24,23.25,5628.75,,0.012,0.001,2209.494,0.0598,0.16,0.0099,38936.475,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-03",18,17.03,4000.6,,0.008,0.001,1571.307,0.0643,0.134,0.0151,27689.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-04",18,17.08,3998.68,,0.008,0.001,1587.296,0.0629,0.135,0.0154,27972.794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-05",18,16.5,3129.6,,0.007,0.001,1276.704,0.0671,0.103,0.0149,22499.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-06",17,14.95,2533.79,,0.006,0.001,1090.095,0.066,0.112,0.023,19210.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-07",11,9.05,1680.98,,0.004,0.001,714.697,0.0698,0.074,0.0246,12594.879,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-08",21,19.59,3717.41,,0.008,0.001,1542.105,0.064,0.128,0.016,27175.464,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-09",19,18.38,4502.16,,0.009,0.001,1795.892,0.0612,0.142,0.0138,31647.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-10",19,17.3,4187.79,,0.009,0.001,1664.398,0.0673,0.147,0.0178,29330.448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-11",16,15.1,3506,,0.007,0.001,1393.096,0.0651,0.121,0.0164,24550.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-12",19,18.13,4020.8,,0.009,0.001,1638.989,0.0614,0.135,0.0139,28882.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-13",9,7.63,1494.62,,0.003,0.001,629.902,0.0757,0.078,0.0333,11101.206,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-14",17,15.45,2992.64,,0.007,0.001,1251.202,0.0706,0.11,0.0202,22049.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-15",17,14.07,3072.81,,0.007,0.001,1246.602,0.0775,0.123,0.0275,21967.423,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-16",16,13.84,2797.5,,0.006,0.001,1149.399,0.0733,0.115,0.0259,20254.488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-17",20,17.7,3119.46,,0.007,0.001,1329.801,0.0704,0.114,0.022,23435.076,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-18",19,18.17,3698.62,,0.008,0.001,1513.306,0.0607,0.126,0.0133,26667.999,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-19",11,10.22,2422.45,,0.005,0.001,972.8,0.0635,0.092,0.0182,17143.77,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-20",9,8.18,1911.18,,0.004,0.001,773.999,0.0663,0.08,0.0219,13640.538,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-21",12,10.59,2344.96,,0.005,0.001,949.499,0.0713,0.086,0.0228,16732.763,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-22",11,10,2416.15,,0.005,0.001,959.9,0.0658,0.091,0.0178,16915.583,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-23",16,15.1,3442.56,,0.007,0.001,1383.1,0.0645,0.122,0.0163,24374.608,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-24",19,17.6,4039.18,,0.009,0.001,1613.304,0.0646,0.13,0.0153,28429.904,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-25",18,16.65,3659.96,,0.008,0.001,1478.204,0.064,0.129,0.0177,26049.453,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-29",12,10.65,1800.1,,0.004,0.001,789.101,0.075,0.16,0.0437,13906.695,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-06-30",11,9.58,2159.74,,0.005,0.001,876.302,0.0735,0.087,0.0272,15442.468,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-01",8,6.77,1486.26,,0.003,0.001,602.401,0.0731,0.073,0.0289,10569.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-02",9,8.15,1328.9,,0.003,0.001,566.099,0.0621,0.067,0.024,9933.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-03",10,8.54,1981.72,,0.004,0.0009,808.003,4.0042,0.089,0.0301,14178.132,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-04",9,7.75,1780.38,,0.004,0.001,729.903,0.0752,0.078,0.0274,12807.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-05",11,10.63,2495.2,,0.005,0.001,1011.296,0.0624,0.094,0.0169,17744.501,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-06",22,21.22,4800.96,,0.01,0.001,1946.001,0.0616,0.142,0.0108,34146.718,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-07",7,5.66,1306.81,,0.003,0.001,525.802,0.0769,0.075,0.0334,9225.444,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-08",8,6.79,1586.89,,0.003,0.001,635.503,0.0729,0.077,0.0295,11151.787,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-09",11,9.63,2331.72,,0.005,0.001,930.999,0.0719,0.094,0.0244,16335.528,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-10",13,11.57,2775.88,,0.006,0.001,1103.5,0.0718,0.104,0.0237,19363.342,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-11",10,9.12,2218.15,,0.005,0.001,880.5,0.0677,0.092,0.0233,15449.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-12",10,8.58,2077.02,,0.004,0.001,827.103,0.0731,0.087,0.0269,14513.889,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-13",11,10.32,2229.4,,0.005,0.001,904.796,0.066,0.081,0.0195,15876.072,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-14",23,22.2,4869.4,,0.01,0.001,1976.399,0.0617,0.144,0.0109,34678.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-15",10,8.51,1893.02,,0.004,0.001,763.296,0.0771,0.075,0.0277,13393.386,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-16",9,7.5,1437.05,,0.003,0.001,596.7,0.0753,0.062,0.0292,10470.886,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-17",8,7.35,1652.4,,0.003,0.001,664.8,0.0699,0.07,0.0246,11664.295,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-18",7,5.88,1382.34,,0.003,0.001,555.9,0.0739,0.068,0.0291,9753.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-19",7,6.05,1329.85,,0.003,0.001,538.401,0.0719,0.062,0.027,9447.345,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-20",10,8.63,2037.45,,0.004,0.001,818.503,0.0729,0.088,0.0275,14361.386,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-21",10,8.4,2010.83,,0.004,0.001,800.302,0.0874,0.085,0.0215,14043.192,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-22",7,6.44,1442.19,,0.003,0.001,578.202,0.0763,0.059,0.0226,10146.234,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-23",7,5.68,1275.28,,0.003,0.001,515.999,0.0771,0.058,0.0323,9054.718,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-24",7,6.37,1483.54,,0.003,0.001,594.799,0.0607,0.075,0.0186,10437.431,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-25",8,6.27,1479.21,,0.003,0.001,593.399,0.2389,0.071,0.0193,10411.462,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-26",9,7.36,1757.48,,0.004,0.001,708.599,0.1331,0.088,0.0206,12433.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-27",14,12.46,3014.41,,0.006,0.001,1200.197,0.0796,0.11,0.0271,21059.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-28",13,12.08,3025.8,,0.006,0.001,1199.399,0.092,0.118,0.0144,21045.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-29",24,24,6051,,0.013,0.001,2384.688,0.0571,0.171,0.0082,41843.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-30",16,13.72,3403.57,,0.007,0.001,1348.703,0.0759,0.123,0.0251,23664.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-07-31",14,13.37,2932.43,,0.006,0.001,1180.103,0.0649,0.101,0.0173,20706.686,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-01",14,11.63,2545.32,,0.005,0.001,1017.997,0.0891,0.095,0.0354,17931.028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-02",11,9.59,2359.19,,0.005,0.001,936.099,0.0736,0.089,0.0251,16487.43,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-03",12,10.46,2209.65,,0.005,0.001,891.401,0.0759,0.087,0.028,15700.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-04",7,5.56,1310.66,,0.003,0.001,530.701,0.0801,0.062,0.0329,9347.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-05",11,9.76,2233.72,,0.005,0.001,903.903,0.0684,0.096,0.0245,15921.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-06",7,5.7,1194.04,,0.003,0.001,489.203,0.0733,0.061,0.0321,8617.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-07",7,5.52,1285.24,,0.003,0.001,520.701,0.0829,0.067,0.0354,9170.776,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-08",9,7.57,1816.92,,0.004,0.001,731.603,0.076,0.078,0.028,12885.868,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-09",8,6.6,1586.86,,0.003,0.001,633.6,0.0783,0.069,0.0305,11160.508,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-10",12,10.59,2606.8,,0.005,0.001,1040.001,0.0713,0.098,0.0233,18318.521,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-11",13,12.32,2819.9,,0.006,0.001,1131.604,0.0646,0.107,0.019,19932.269,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-12",18,16.52,3814.85,,0.008,0.001,1528.1,0.0696,0.131,0.0206,26915.996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-13",20,18.53,4686.77,,0.01,0.001,1836.99,0.0664,0.146,0.0155,32356.59,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-14",22,21.33,5129.17,,0.011,0.001,2019.204,0.062,0.162,0.0137,35565.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-15",24,24,5906,,0.012,0.001,2316.192,0.0572,0.166,0.0081,40796.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-16",24,24,5800,,0.012,0.001,2278.8,0.0573,0.166,0.0083,40136.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-17",24,23.63,6006.05,,0.012,0.001,2345.396,0.0579,0.172,0.0087,41311.086,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-18",21,20.27,5152.72,,0.011,0.001,2014.696,0.0634,0.161,0.014,35485.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-19",24,24,5292,,0.011,0.001,2111.088,0.0593,0.153,0.0082,37184.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-20",24,23.47,4316.2,,0.009,0.001,1777.406,0.0582,0.135,0.0091,31305.552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-21",21,20.32,5011.76,,0.01,0.001,1966.59,0.0626,0.164,0.0148,34638.596,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-22",24,24,5652,,0.012,0.001,2233.488,0.0588,0.164,0.0083,39339.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-23",17,15.52,3702.84,,0.008,0.001,1460.805,0.0689,0.128,0.0198,25729.364,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-24",22,19.75,4936.99,,0.01,0.001,1937.001,0.0695,0.169,0.0191,34116.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-25",21,20.33,4994.5,,0.01,0.001,1963.105,0.0618,0.16,0.0142,34577.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-26",24,24,5318,,0.011,0.001,2121.6,0.0584,0.156,0.0083,37369.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-27",24,23.13,4173.46,,0.009,0.001,1727.695,0.0633,0.127,0.0129,30430.739,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-28",13,11.56,2601.55,,0.005,0.001,1037.602,0.0692,0.095,0.0218,18275.907,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-29",17,16.42,3504.38,,0.008,0.001,1434.402,0.0606,0.12,0.0144,25264.766,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-30",13,10.38,2039,,0.004,0.001,840.603,0.1015,0.089,0.031,14806.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-08-31",11,9.48,1911.34,,0.004,0.001,788.404,0.0785,0.079,0.0298,13886.554,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-01",8,6.51,1336.17,,0.003,0.001,553.2,0.0793,0.063,0.0328,9668.845,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-02",7,5.58,1176.1,,0.003,0.001,481.9,0.0829,0.061,0.0379,8422.706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-03",16,15.33,3622.52,,0.008,0.001,1449.605,0.0647,0.123,0.0164,25337.355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-04",24,24,5660,,0.012,0.001,2253.6,0.0579,0.161,0.0082,39390,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-05",24,24,4905,,0.01,0.001,1996.992,0.0592,0.142,0.0081,34905.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-06",24,24,5075,,0.011,0.001,2044.2,0.0592,0.146,0.0082,35730.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-07",24,24,5708,,0.012,0.001,2258.304,0.0583,0.159,0.0081,39473.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-08",24,23.13,4906.68,,0.01,0.001,1985.687,0.0655,0.146,0.0132,34707.679,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-09",12,10.25,1832.1,,0.004,0.001,771.302,0.0875,0.08,0.0255,13481.077,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-10",13,11.79,2327.29,,0.005,0.001,961.899,0.0649,0.091,0.0198,16812.067,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-11",12,10.94,2450.01,,0.005,0.001,1003.198,0.0653,0.102,0.0215,17535.274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-12",9,7.62,1833.94,,0.004,0.001,734.499,0.0751,0.081,0.029,12838.774,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-13",9,7.7,1747.66,,0.004,0.001,720.597,0.076,0.085,0.0312,12594.914,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-14",10,8.7,2031.9,,0.004,0.001,833.903,0.0729,0.086,0.0273,14575.216,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-15",12,10.65,2480.7,,0.005,0.001,1008.098,0.074,0.095,0.0248,17621.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-16",10,8.63,2064.19,,0.004,0.001,829.896,0.0727,0.086,0.0262,14505.396,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-17",11,9.6,2293.2,,0.005,0.001,919.699,0.0756,0.096,0.0268,16075.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-18",9,7.59,1612.61,,0.003,0.001,662.402,0.0741,0.07,0.0268,11578.081,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-19",7,5.62,1272.6,,0.003,0.001,518.102,0.1319,0.07,0.0207,9055.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-20",7,5.57,1292.48,,0.003,0.001,525.501,0.2199,0.067,0.0144,9185.262,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-21",10,8.42,1911.02,,0.004,0.001,774.303,0.0902,0.09,0.0223,13534.203,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-22",14,11.12,2322.39,,0.005,0.001,953.796,0.0934,0.111,0.0323,16671.281,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-23",9,7.28,1531.62,,0.003,0.001,627.303,0.1046,0.09,0.0362,10965.353,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-24",14,12.78,3017.04,,0.006,0.001,1212.004,0.0747,0.109,0.0221,21184.358,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-25",16,14.3,3374,,0.007,0.001,1355.497,0.0864,0.125,0.017,23692.81,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-26",16,14.34,3340.58,,0.007,0.001,1347.902,0.0899,0.12,0.0166,23559.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-27",18,16.48,3705.4,,0.008,0.001,1501.394,0.0995,0.134,0.0127,26242.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-28",20,18.75,4003.85,,0.009,0.001,1629.094,0.0629,0.13,0.0131,28474.931,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-29",20,18.63,4378.3,,0.009,0.001,1743.097,0.0642,0.142,0.0145,30467.586,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-09-30",16,14.62,3477.62,,0.007,0.001,1387.701,0.0685,0.128,0.0211,24254.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-01",20,17.93,4164.49,,0.009,0.001,1646.905,0.0686,0.162,0.022,28898.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-02",14,12.78,3101.35,,0.006,0.001,1233.5,0.0669,0.121,0.0198,21644.365,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-03",11,9.35,2263.1,,0.005,0.001,906.903,0.0885,0.095,0.0237,15913.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-04",13,11.79,2782.5,,0.006,0.001,1129.694,0.0653,0.103,0.0183,19822.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-05",21,19.88,4850.76,,0.01,0.001,1962.494,0.0619,0.164,0.0154,34435.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-06",13,12.1,2966.7,,0.006,0.001,1178.697,0.1026,0.11,0.0135,20682.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-07",20,18.63,4573.23,,0.009,0.001,1800.794,0.0604,0.161,0.0129,31598.372,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-08",7,5.6,1200.92,,0.003,0.001,491.299,0.0789,0.059,0.0341,8621.466,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-09",20,18.8,4135.43,,0.009,0.001,1672.203,0.0621,0.134,0.0133,29342.314,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-10",16,14.77,3269.08,,0.007,0.001,1318.799,0.0644,0.122,0.0187,23141.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-11",7,5.63,1031.77,,0.002,0.001,435.599,0.0769,0.06,0.04,7643.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-12",7,5.5,1057.05,,0.002,0.001,439.802,0.0884,0.06,0.0454,7717.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-13",19,17.27,3907.28,,0.008,0.001,1571.19,0.1228,0.142,0.0176,27569.768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-14",22,21.3,5109.7,,0.011,0.001,2010.294,0.0628,0.164,0.0146,35275.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-15",24,24,5987,,0.012,0.001,2339.304,0.0571,0.168,0.0082,41047,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-16",22,20.5,4877.34,,0.01,0.001,1928.394,0.0676,0.161,0.0185,33836.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-17",20,18.27,4213.13,,0.009,0.001,1667.796,0.0648,0.156,0.0174,29265.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-18",10,9.35,2312.35,,0.005,0.001,921.901,0.0684,0.092,0.0222,16176.105,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-19",21,19.52,4794.92,,0.01,0.001,1914.794,0.0909,0.168,0.012,33599.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-20",24,23.22,5793.8,,0.012,0.001,2312.108,0.0597,0.174,0.0105,40571.104,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-21",20,19.05,4542.25,,0.01,0.001,1823.599,0.0998,0.144,0.0131,31998.665,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-22",24,24,5838,,0.012,0.001,2307.288,0.0573,0.165,0.0081,40485.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-23",24,23.32,5584.44,,0.012,0.001,2209.687,0.0582,0.163,0.0094,38773.944,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-29",10,9.7,2261.7,,0.005,0.001,905.398,0.069,0.144,0.0346,15886.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-30",20,19.17,4565.97,,0.01,0.001,1825.904,0.0607,0.155,0.0135,32039.248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-10-31",19,17.38,4177.26,,0.009,0.001,1668.097,0.0716,0.152,0.0198,29269.934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-01",20,18.32,4016.28,,0.009,0.001,1623.207,0.11,0.155,0.013,28803.682,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-02",24,24,6104,,0.013,0.001,2413.392,0.0564,0.174,0.0081,42824.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-03",24,24,6138,,0.013,0.001,2424.888,0.0564,0.175,0.0081,43029.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-04",24,24,6149,,0.013,0.001,2412.696,0.0563,0.173,0.0081,42812.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-05",24,24,5999,,0.013,0.001,2371.704,0.0565,0.168,0.008,42084.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-06",24,24,5365,,0.011,0.001,2135.808,0.0572,0.152,0.008,37898.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-07",24,24,5504,,0.012,0.001,2206.896,0.0568,0.158,0.0081,39160.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-08",8,5.91,1250.95,,0.003,0.001,510.299,0.0821,0.082,0.0479,9054.579,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-09",17,14.99,3537.11,,0.008,0.0009,1409.795,2.3656,0.138,0.0152,25016.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-10",19,17.23,4363.39,,0.009,0.001,1718.4,0.0924,0.168,0.0196,30492.923,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-11",20,18.55,4598.53,,0.01,0.001,1818.902,0.088,0.174,0.013,32276.088,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-12",20,18.79,4454.34,,0.009,0.001,1760.492,0.0631,0.159,0.0171,31240.544,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-13",19,16.72,3905.13,,0.008,0.001,1549.192,0.0722,0.139,0.0249,27490.621,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-14",21,20.12,4617.44,,0.01,0.001,1845.205,0.0712,0.164,0.0132,32742.556,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-15",21,19.62,4731.46,,0.01,0.001,1896.39,0.065,0.166,0.0182,33651.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-16",20,19.22,4421.96,,0.009,0.001,1780.791,0.0603,0.155,0.015,31600.596,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-17",21,19.85,4596.95,,0.01,0.001,1821.893,0.0619,0.156,0.0149,32328.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-18",21,19.55,4506.39,,0.009,0.001,1783.604,0.0934,0.165,0.0126,31649.023,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-19",21,19.7,4467.69,,0.01,0.001,1790.691,0.065,0.159,0.0163,31774.997,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-20",24,24,6009,,0.013,0.001,2349.696,0.0565,0.167,0.008,41694.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-21",21,19.68,4670.68,,0.01,0.001,1853.107,0.067,0.162,0.0166,32882.052,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-22",19,17.95,4083.05,,0.009,0.001,1638.997,0.0605,0.139,0.0144,29082.885,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-23",20,18.88,4521.72,,0.01,0.001,1797.507,0.0628,0.161,0.0171,31895.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-24",20,18.58,4456.8,,0.009,0.001,1774.798,0.0664,0.161,0.0202,31492.302,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-25",21,18.88,4438.13,,0.009,0.001,1771.095,0.0757,0.165,0.0173,31426.671,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-26",19,18.05,3739.25,,0.008,0.001,1516.092,0.1016,0.142,0.01,26903.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-27",19,17.61,3866.78,,0.008,0.001,1568.205,0.0655,0.134,0.0191,27827.604,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-28",18,16.75,4002.25,,0.009,0.001,1603.595,0.0636,0.143,0.0183,28455.276,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-29",18,16.71,4164.76,,0.009,0.001,1661.006,0.0631,0.141,0.0173,29473.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-11-30",20,18.83,4705.92,,0.01,0.001,1869.103,0.0617,0.159,0.015,33167.604,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-01",20,18.56,4592.4,,0.01,0.001,1810.305,0.0909,0.164,0.013,32084.088,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-02",21,19.62,4898.92,,0.01,0.001,1928.803,0.0828,0.169,0.0131,34183.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-03",22,20.61,5218.31,,0.011,0.001,2051.705,0.0637,0.167,0.0167,36362.969,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-04",24,24,6056,,0.013,0.001,2372.496,0.0568,0.169,0.008,42047.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-05",20,19.18,4853.86,,0.01,0.001,1911.9,0.0617,0.162,0.0135,33883.452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-06",20,18.24,4605.6,,0.01,0.001,1815.19,0.1001,0.157,0.0162,32171.262,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-07",24,24,6138,,0.013,0.001,2400.792,0.0565,0.17,0.008,42548.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-08",24,24,5841,,0.012,0.001,2298.192,0.0567,0.165,0.0081,40731.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-09",24,24,5917,,0.012,0.001,2329.704,0.0567,0.167,0.0081,41289.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-10",24,24,5307,,0.011,0.001,2129.496,0.0578,0.147,0.0078,37739.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-11",24,24,5859,,0.012,0.001,2315.592,0.057,0.164,0.008,41038.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-12",24,24,6018,,0.013,0.001,2370.696,0.0567,0.168,0.008,42015.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-13",16,14.68,3474.64,,0.007,0.001,1383.502,0.0655,0.136,0.0211,24518.746,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-14",20,18.59,4595.08,,0.01,0.001,1809.996,0.1115,0.17,0.0119,32078.238,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-15",24,24,6046,,0.013,0.001,2367.096,0.0566,0.168,0.008,41952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-16",24,24,5151,,0.011,0.001,2054.688,0.0573,0.156,0.0086,36415.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-17",20,18.48,3916.1,,0.008,0.001,1565.699,0.0658,0.142,0.0211,27748.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-18",20,19.03,4386.82,,0.009,0.001,1745.602,0.1136,0.161,0.0106,30936.893,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-19",21,20.07,4947.28,,0.01,0.001,1951.908,0.108,0.172,0.0108,34593.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-20",22,20.58,4852.93,,0.01,0.001,1924.003,0.064,0.16,0.0178,34098.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-21",18,15.87,3807.51,,0.008,0.001,1511.093,0.1664,0.165,0.0162,26780.479,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-22",20,18.55,4580.69,,0.01,0.001,1817.102,0.1489,0.17,0.0113,32204.871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-23",24,24,5815,,0.012,0.001,2295.096,0.057,0.164,0.0081,40674.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-24",24,24,6106,,0.013,0.001,2388.288,0.0564,0.171,0.0081,42327.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-25",24,24,5981,,0.012,0.001,2342.304,0.0565,0.168,0.0081,41512.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-26",24,24,5912,,0.012,0.001,2325.408,0.0566,0.165,0.008,41213.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-27",24,24,5944,,0.012,0.001,2338.608,0.0568,0.166,0.008,41446.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-28",24,24,6177,,0.013,0.001,2414.208,0.0566,0.171,0.008,42786.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-29",20,18.53,4628.26,,0.01,0.001,1826.095,0.0665,0.165,0.0201,32362.81,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-30",21,19.58,4734.98,,0.01,0.001,1870.791,0.0925,0.171,0.0128,33155.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"1A",,"2020-12-31",18,16.67,4042.11,,0.008,0.001,1597.002,0.0663,0.148,0.0197,28302.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-01",24,23.18,5032.7,,0.011,0.001,2036.803,0.0606,0.149,0.0105,36225.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-02",18,15.75,3535.75,,0.008,0.001,1434.603,0.0758,0.164,0.0289,25515.039,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-03",21,19.45,4535.95,,0.01,0.001,1819.392,0.0679,0.163,0.0194,32358.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-04",19,17.73,3923.16,,0.008,0.001,1584.902,0.0642,0.147,0.0173,28187.006,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-05",18,17.27,3853.12,,0.008,0.001,1556.494,0.0631,0.146,0.0173,27681.896,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-06",21,19.57,4538.18,,0.01,0.001,1824.608,0.0666,0.181,0.0188,32450.399,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-07",20,18.52,3888.3,,0.008,0.001,1582.997,0.0658,0.141,0.0176,28153.028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-08",22,20.54,4324.72,,0.009,0.001,1771.903,0.065,0.154,0.0177,31513.064,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-09",19,17.54,3891.06,,0.008,0.001,1571.303,0.0661,0.144,0.0181,27945.196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-10",21,20.6,4791.53,,0.01,0.001,1934.402,0.0573,0.179,0.012,34403.621,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-11",17,15.53,2769.26,,0.006,0.001,1165.294,0.0648,0.114,0.0201,20725.188,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-12",19,17.95,3755.3,,0.008,0.001,1533.899,0.0638,0.139,0.0164,27280.865,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-13",21,19.57,4072.83,,0.009,0.001,1672.706,0.066,0.145,0.019,29748.911,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-14",21,19.54,4084.08,,0.009,0.001,1670.299,0.0648,0.131,0.013,29706.616,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-15",24,24,5085,,0.011,0.001,2071.608,0.0575,0.151,0.0082,36843.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-16",21,18.45,3946.25,,0.009,0.001,1601.404,0.1195,0.15,0.0149,28481.322,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-17",20,19.3,4395.4,,0.009,0.001,1772.396,0.0624,0.134,0.0108,31521.98,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-18",21,19.51,4358.23,,0.009,0.001,1749.891,0.4615,0.181,0.0123,31122.271,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-19",24,24,5791,,0.012,0.001,2313.888,0.0564,0.166,0.0081,41153.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-20",22,20.53,4670.85,,0.01,0.001,1881.204,0.0639,0.163,0.0173,33457.804,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-21",21,19.63,4232.03,,0.009,0.001,1706.691,0.0635,0.133,0.0122,30352.722,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-22",12,10.61,2271.6,,0.005,0.001,930.603,0.0681,0.102,0.0254,16549.814,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-23",19,16.13,3375.96,,0.007,0.001,1381.501,0.1809,0.175,0.0225,24569.167,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-24",21,19.28,4024.85,,0.009,0.001,1647.398,0.1253,0.156,0.0124,29299.057,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-25",17,14.22,3143.48,,0.007,0.001,1272.803,0.0975,0.135,0.0211,22636.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-26",9,6.65,1420.9,,0.003,0.001,582.001,0.0904,0.088,0.0469,10350.099,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-27",18,16.15,3146.66,,0.007,0.001,1311.395,0.0673,0.136,0.0259,23322.905,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-28",19,16.29,3352.71,,0.007,0.001,1389.405,0.0743,0.174,0.0337,24710.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-29",18,15.21,3373.73,,0.007,0.001,1375.897,0.1436,0.162,0.0226,24470.525,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-30",21,18.85,4262.16,,0.009,0.001,1712.504,0.0668,0.139,0.0156,30456.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-01-31",16,13.77,3007.36,,0.007,0.001,1219.704,0.0778,0.145,0.0343,21692.148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-01",10,8.56,1980.26,,0.004,0.001,797.697,0.0736,0.1,0.0314,14163.324,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-02",10,7.77,1698.63,,0.004,0.001,687.598,0.0774,0.089,0.0343,12208.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-03",17,14.85,3358.45,,0.007,0.001,1356.994,0.2634,0.142,0.0146,24095.497,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-04",19,17.25,4067.8,,0.009,0.001,1629.607,0.1254,0.158,0.0149,28934.553,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-05",24,24,5379,,0.012,0.001,2174.304,0.0576,0.16,0.0083,38606.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-06",22,20.5,4320.94,,0.009,0.001,1762.098,0.0651,0.159,0.019,31287.756,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-07",16,13.87,3093.11,,0.007,0.001,1252.197,0.0726,0.161,0.0287,22233.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-08",17,15.47,3460.68,,0.007,0.001,1387.799,0.0706,0.135,0.0229,24642.078,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-09",17,14.39,3185.67,,0.007,0.001,1283.199,0.1718,0.165,0.0204,22784.873,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-10",20,19.1,4455.6,,0.009,0.001,1773.607,0.0938,0.151,0.0142,31491.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-11",17,14.8,3157.95,,0.007,0.001,1285.099,0.0687,0.157,0.0271,22818.038,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-12",18,16.2,3540.24,,0.008,0.0009,1429.196,0.1871,0.134,0.0169,25376.815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-13",17,14.1,3166.35,,0.007,0.001,1276.797,0.3705,0.138,0.0181,22670.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-14",19,17.3,4055.8,,0.009,0.001,1623.691,0.1211,0.161,0.0146,28830.864,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-15",18,16.3,3525.8,,0.008,0.001,1428.499,0.1233,0.141,0.0139,25363.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-16",22,19.84,4361.61,,0.009,0.001,1765.7,0.0902,0.172,0.0146,31351.875,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-17",20,19.3,4301,,0.009,0.001,1734.993,0.0626,0.131,0.011,30805.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-18",19,17.45,3833.05,,0.008,0.001,1547.693,0.0693,0.129,0.0189,27479.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-19",19,18.5,4352,,0.009,0.001,1748.195,0.0574,0.165,0.0119,31041,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-20",17,13.85,3040.55,,0.007,0.001,1235.503,0.2545,0.163,0.0285,21937.255,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-21",21,19.48,4670.64,,0.01,0.001,1863.496,0.067,0.162,0.0189,33087.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-22",16,13.07,2733.59,,0.006,0.001,1115.498,0.0766,0.13,0.0267,19807.475,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-23",20,18.05,3917.75,,0.008,0.001,1582.389,0.0645,0.144,0.0192,28097.255,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-24",16,13.86,3172.3,,0.007,0.001,1283.201,0.1144,0.139,0.0174,22783.978,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-25",18,16.55,3763.36,,0.008,0.001,1514.292,0.067,0.134,0.0199,26887.336,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-26",24,24,5279,,0.011,0.001,2123.496,0.0571,0.153,0.0081,37704.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-27",24,24,5561,,0.012,0.001,2223.888,0.0569,0.163,0.0083,39487.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-28",21,19.5,4319.12,,0.009,0.001,1740.589,0.0666,0.134,0.0123,30905.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-02-29",18,15.92,3454.55,,0.007,0.001,1395.898,0.0691,0.139,0.0234,24785.689,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-01",8,7.3,1723.4,,0.004,0.001,695.602,0.072,0.096,0.0331,12248.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-02",20,18.7,3985,,0.009,0.001,1620.093,0.0672,0.155,0.0173,28530.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-03",19,17.34,4041.78,,0.009,0.001,1623.804,0.1323,0.15,0.0123,28595.117,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-04",24,24,5505,,0.012,0.001,2213.088,0.0573,0.162,0.0083,38972.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-05",24,24,5863,,0.012,0.001,2355.888,0.0568,0.17,0.0082,41488.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-06",19,17.47,4062.77,,0.009,0.001,1644.905,0.0707,0.151,0.0213,28967.961,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-07",21,19.5,4623.65,,0.01,0.001,1870.401,0.1202,0.173,0.0111,32938.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-08",18,16.78,3940.84,,0.008,0.001,1594.201,0.0651,0.149,0.0186,28075.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-09",20,18.25,4304.75,,0.009,0.001,1736.999,0.1434,0.17,0.0136,30589.565,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-10",24,24,5558,,0.012,0.001,2241.6,0.0583,0.162,0.0082,39474.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-11",18,15.02,3398.53,,0.007,0.001,1381.704,0.079,0.161,0.0314,24331.863,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-12",24,24,5910,,0.012,0.001,2364.096,0.0569,0.17,0.0082,41631.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-13",19,16.78,4057.08,,0.009,0.001,1621.703,0.0705,0.146,0.0215,28559.443,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-14",12,9.83,2268.88,,0.005,0.001,926.202,0.0773,0.127,0.0366,16309.843,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-15",19,18.07,4234.59,,0.009,0.001,1704.001,0.0639,0.152,0.0173,30007.766,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-16",22,21.23,5154.61,,0.011,0.001,2061.391,0.0592,0.153,0.0101,36302.048,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-17",20,19.32,4208.16,,0.009,0.001,1708.893,0.0633,0.131,0.0112,30094.452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-18",24,23.22,5435.16,,0.012,0.001,2196.891,0.0603,0.164,0.0104,38688.086,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-19",16,13.85,3118.84,,0.007,0.001,1265.294,0.0768,0.156,0.0334,22283.076,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-20",18,16.54,3715.34,,0.008,0.001,1505.603,0.0673,0.143,0.0203,26514.414,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-21",20,18.45,4178.35,,0.009,0.001,1695.703,0.069,0.162,0.0185,29862.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-22",18,15.7,3704.84,,0.008,0.001,1489.6,0.0741,0.152,0.0247,26233.191,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-23",18,16.21,3215.76,,0.007,0.001,1337.405,0.0672,0.157,0.027,23552.013,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-24",24,23.25,5251.75,,0.011,0.001,2124.004,0.0595,0.164,0.0101,37404.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-25",21,19.59,4006.68,,0.009,0.001,1638.998,0.064,0.15,0.0179,28862.548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-26",20,17.63,3741.29,,0.008,0.001,1526.704,0.0735,0.147,0.0185,26886.118,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-27",15,13.15,3023.55,,0.006,0.001,1220.596,0.0719,0.126,0.022,21494.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-28",10,8.52,1911.61,,0.004,0.0009,774.298,0.2753,0.111,0.0309,13636.285,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-29",17,15.72,3615.96,,0.008,0.001,1460.907,0.066,0.133,0.0176,25727.308,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-30",18,16.93,3658.13,,0.008,0.001,1493.7,0.0628,0.138,0.0158,26303.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-03-31",16,13.74,2658.27,,0.006,0.001,1101.096,0.0713,0.114,0.0254,19391.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-01",14,11.35,2218.85,,0.005,0.001,923.198,0.1562,0.121,0.0289,16289.838,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-02",18,15,2922.12,,0.006,0.001,1208.895,0.0761,0.155,0.0337,21332.217,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-03",14,11.28,2223.19,,0.005,0.001,922.004,0.0762,0.134,0.039,16269.969,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-10",22,21.95,4689.95,,0.01,0.001,1944.506,0.0632,0.306,0.031,34311.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-11",10,8.55,1792.69,,0.004,0.001,734.898,0.0738,0.085,0.0301,12968.378,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-12",22,21.12,4481.18,,0.01,0.001,1828.801,0.0605,0.166,0.0133,32271.622,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-13",21,19.45,3817.9,,0.008,0.001,1573.894,0.0676,0.137,0.0194,27773.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-14",18,16.62,3605.64,,0.008,0.001,1465.9,0.0664,0.134,0.0184,25867.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-15",15,13.7,2866.72,,0.006,0.001,1171.802,0.0657,0.114,0.02,20677.31,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-16",18,15.7,3452.28,,0.007,0.001,1395.4,0.0723,0.131,0.023,24624.288,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-17",8,7.38,1656.58,,0.004,0.001,672.901,0.0698,0.081,0.0309,11874.556,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-18",20,18.5,4087.4,,0.009,0.001,1662.206,0.0676,0.148,0.0187,29330.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-19",7,6.2,1315.8,,0.003,0.001,535.599,0.0683,0.042,0.0159,9451.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-20",15,13.17,2675.45,,0.006,0.001,1102.803,0.0709,0.126,0.0277,19459.817,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-21",20,18.38,3624.57,,0.008,0.001,1508.905,0.0664,0.13,0.0168,26627.066,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-22",15,12.83,2475.84,,0.005,0.001,1022.102,0.0761,0.122,0.0333,18036.412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-23",20,17,3456.42,,0.008,0.001,1420.996,0.0776,0.156,0.0315,25074.931,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-24",24,24,5098,,0.011,0.001,2064.288,0.0577,0.148,0.0082,36426.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-25",10,8.87,2053.11,,0.004,0.001,827.696,0.0672,0.087,0.0263,14605.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-26",19,17.47,3255.19,,0.007,0.001,1362.59,0.0688,0.129,0.0195,24044.375,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-27",9,6.6,1373.98,,0.003,0.001,561.6,0.0938,0.088,0.0444,9909.635,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-28",11,9.63,2179.09,,0.005,0.001,880.201,0.0719,0.096,0.0282,15532.094,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-01",10,9.8,1929.6,,0.004,0.001,816.095,0.0632,0.126,0.0312,14392.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-02",11,10.17,1604.69,,0.004,0.001,699.503,0.0648,0.053,0.0141,12335.896,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-03",10,9.55,1923.55,,0.004,0.001,806.201,0.0649,0.098,0.0274,14216.65,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-04",8,6.59,1491.31,,0.003,0.001,604,0.078,0.084,0.0355,10651.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-06",15,12.46,2396.95,,0.005,0.001,987.405,0.0759,0.149,0.0386,17412.609,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-07",18,17.33,3381.8,,0.007,0.001,1401.304,0.062,0.125,0.0174,24711.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-08",8,7.3,1695.24,,0.004,0.001,680.702,0.0718,0.085,0.0301,12004.273,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-09",8,6.78,1560.44,,0.003,0.001,627.699,0.0731,0.088,0.0334,11069.819,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-10",7,5.55,1174.85,,0.003,0.001,477.3,0.0824,0.066,0.0413,8417.805,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-11",8,6.57,1499.14,,0.003,0.001,603.599,0.3753,0.089,0.0168,10643.958,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-12",18,16.57,3307.85,,0.007,0.001,1357,0.0653,0.126,0.0191,23930.049,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-13",18,17.13,3481.18,,0.008,0.001,1423.692,0.0631,0.116,0.0136,25105.871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-14",9,7.35,1530.87,,0.003,0.001,626,0.159,0.076,0.0434,11039.723,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-18",7,5.91,907.33,,0.002,0.001,391.898,0.07,0.079,0.0461,6911.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-19",7,5.53,771.15,,0.002,0.001,340.001,0.0683,0.032,0.0223,5995.156,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-21",18,17.55,3239.9,,0.007,0.001,1356.404,0.0622,0.143,0.0203,23919.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-22",16,13.39,2293.84,,0.005,0.001,970.092,0.0735,0.137,0.0336,17107.785,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-23",17,14.8,2703.27,,0.006,0.001,1127.894,0.0711,0.125,0.0268,19889.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-24",12,9.35,1862.55,,0.004,0.0009,765.801,0.2243,0.092,0.0246,13504.665,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-25",8,6.46,1508.37,,0.003,0.001,605.398,0.0871,0.084,0.0344,10676.143,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-26",18,17.27,3884.72,,0.008,0.001,1558.203,0.0646,0.135,0.0169,27477.233,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-27",19,17.47,3985.73,,0.008,0.001,1596.199,0.0699,0.138,0.0204,28148.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-28",24,23.17,4743.2,,0.01,0.001,1935.39,0.0615,0.14,0.0109,34130.274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-29",18,16.47,3495.63,,0.007,0.001,1413.291,0.0683,0.126,0.0191,24922.053,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-30",8,7.8,1311.4,,0.003,0.001,556.101,0.0594,0.065,0.0171,9806.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-05-31",10,8.52,1479.46,,0.003,0.001,622.497,0.0701,0.073,0.0273,10976.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-01",24,24,5812,,0.012,0.001,2319.792,0.057,0.164,0.008,40879.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-02",18,16.51,3886.52,,0.008,0.001,1538.006,0.0675,0.148,0.0204,27103.384,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-03",24,24,5760,,0.012,0.001,2278.992,0.0577,0.162,0.0081,40161.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-04",19,17.53,4185.7,,0.009,0.001,1659.197,0.0666,0.149,0.0179,29240.213,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-05",24,23.2,4790,,0.01,0.001,1938.29,0.0614,0.141,0.01,34157.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-06",6,5.27,1072.72,,0.002,0.001,442.2,0.075,0.066,0.0363,7793.091,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-07",11,9.45,2004.55,,0.004,0.001,821.904,0.0782,0.086,0.0292,14483.065,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-08",19,17.52,3297.46,,0.007,0.001,1363.704,0.0653,0.122,0.0183,24031.322,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-09",13,11.5,2758.1,,0.006,0.001,1104.598,0.0732,0.11,0.0243,19465.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-10",24,24,5881,,0.012,0.001,2356.704,0.0569,0.166,0.008,41530.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-11",23,22.72,5278.28,,0.011,0.001,2124.888,0.0579,0.156,0.0085,37446.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-12",8,7,1451.2,,0.003,0.001,598.402,0.1426,0.087,0.0194,10544.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-13",8,7.37,1598.54,,0.003,0.001,651.899,0.0691,0.086,0.0324,11489.013,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-14",9,7.47,1599.04,,0.003,0.001,652.4,0.0821,0.077,0.0327,11495.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-15",20,18.52,4263.74,,0.009,0.001,1718.897,0.0667,0.144,0.0176,30292.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-16",24,24,5385,,0.012,0.001,2198.496,0.0581,0.161,0.0083,38743.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-17",11,8.99,1889.31,,0.004,0.001,772.798,0.0725,0.086,0.0261,13618.108,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-18",19,17.79,3623.12,,0.008,0.001,1480.804,0.0632,0.138,0.0179,26096.026,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-19",11,9.52,2229.2,,0.005,0.001,892.595,0.075,0.107,0.0275,15730.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-20",9,8.33,1910.2,,0.004,0.001,767.301,0.0691,0.083,0.0271,13522,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-21",14,12.28,2689.74,,0.006,0.001,1084.594,0.0972,0.111,0.0174,19113.357,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-22",24,23.45,5657.3,,0.012,0.001,2260.697,0.0575,0.165,0.0087,39839.285,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-23",16,15.05,3499.69,,0.007,0.001,1401.304,0.0662,0.135,0.0192,24694.615,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-24",19,17.6,4002.1,,0.008,0.001,1604.293,0.0672,0.153,0.0195,28272.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-25",18,16.53,3669.13,,0.008,0.001,1477.6,0.0678,0.132,0.0191,26039.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-29",8,7.7,1529.9,,0.003,0.001,629.899,0.067,0.102,0.0348,11099.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-06-30",15,13.5,2734.9,,0.006,0.001,1127.398,0.07,0.103,0.0201,19867.004,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-01",24,24,5536,,0.012,0.001,2252.088,0.0575,0.158,0.008,39517.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-02",24,24,4796,,0.01,0.001,1992.6,0.0583,0.142,0.0082,34963.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-03",10,8.49,1949.57,,0.004,0.001,790.402,0.0784,0.112,0.0322,13869.143,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-04",10,8.48,1955.45,,0.004,0.001,795.399,0.1382,0.099,0.016,13957.404,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-05",9,7.46,1762.58,,0.004,0.001,712.4,0.0829,0.082,0.0327,12500.414,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-06",10,9.28,2069.52,,0.004,0.001,842.104,0.0707,0.1,0.0266,14776.488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-07",24,24,4953,,0.011,0.001,2056.2,0.058,0.154,0.0086,36079.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-08",24,24,4878,,0.011,0.001,2030.904,0.0587,0.144,0.0081,35635.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-09",24,24,5606,,0.012,0.001,2276.592,0.0573,0.16,0.008,39947.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-10",24,24,5290,,0.011,0.001,2158.704,0.0579,0.152,0.008,37878.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-11",24,24,5656,,0.012,0.001,2281.896,0.0574,0.16,0.008,40040.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-12",24,24,5724,,0.012,0.001,2305.2,0.0573,0.163,0.008,40448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-13",23,22.17,5140.52,,0.011,0.001,2080.898,0.0624,0.149,0.0109,36514.161,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-14",11,10.33,2353.2,,0.005,0.001,952.705,0.0677,0.09,0.023,16717.543,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-15",24,24,5104,,0.011,0.001,2090.688,0.0576,0.148,0.0081,36685.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-16",24,24,4684,,0.01,0.001,1953.288,0.0582,0.138,0.0081,34274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-17",24,24,5191,,0.011,0.001,2124.408,0.0577,0.15,0.008,37276.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-18",24,24,5747,,0.012,0.001,2315.904,0.0571,0.163,0.008,40637.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-19",24,24,5229,,0.011,0.001,2142.288,0.0576,0.152,0.0081,37590.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-20",24,24,5362,,0.012,0.001,2194.8,0.058,0.155,0.0081,38511.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-21",24,24,5705,,0.012,0.001,2295.6,0.0573,0.162,0.008,40280.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-22",24,24,4966,,0.011,0.001,2047.608,0.0583,0.144,0.008,35928.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-23",24,24,5016,,0.011,0.001,2069.904,0.0575,0.146,0.008,36319.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-24",24,24,5430,,0.012,0.001,2202.096,0.0574,0.155,0.008,38639.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-25",24,24,5663,,0.012,0.001,2289.192,0.0574,0.161,0.008,40169,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-26",24,24,5819,,0.012,0.001,2352.192,0.057,0.166,0.008,41272.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-27",24,24,5802,,0.012,0.001,2337.504,0.057,0.164,0.008,41014.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-28",24,24,5948,,0.013,0.001,2380.608,0.057,0.168,0.008,41772.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-29",24,24,5960,,0.013,0.001,2376.192,0.0571,0.167,0.008,41695.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-30",24,24,5950,,0.013,0.001,2379.792,0.057,0.167,0.008,41758.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-07-31",24,24,5522,,0.012,0.001,2230.704,0.0577,0.158,0.0081,39142.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-01",24,24,5199,,0.011,0.001,2104.992,0.0577,0.149,0.008,37076.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-02",24,24,5881,,0.012,0.001,2348.496,0.0569,0.165,0.008,41365.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-03",24,24,5495,,0.012,0.001,2207.208,0.0573,0.152,0.0078,38875.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-04",24,24,5405,,0.012,0.001,2210.208,0.0575,0.136,0.007,38929.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-05",18,16.46,3461.3,,0.008,0.001,1425.6,0.0726,0.114,0.0197,25109.133,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-06",24,24,5038,,0.011,0.001,2078.088,0.0577,0.132,0.0073,36602.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-07",24,24,5136,,0.011,0.001,2132.496,0.058,0.138,0.0074,37561.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-08",24,24,5678,,0.012,0.001,2318.088,0.057,0.151,0.0075,40830.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-09",24,24,5814,,0.012,0.001,2334.6,0.057,0.144,0.007,41121.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-10",24,24,5716,,0.012,0.001,2314.704,0.0572,0.144,0.0071,40769.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-11",24,24,5250,,0.011,0.001,2146.608,0.0575,0.132,0.007,37809.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-12",24,24,5255,,0.011,0.001,2140.896,0.0585,0.132,0.007,37707.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-13",24,24,5941,,0.012,0.001,2364.192,0.0571,0.146,0.007,41642.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-14",24,24,5666,,0.012,0.001,2258.688,0.0576,0.141,0.0071,39782.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-15",24,24,5785,,0.012,0.001,2292,0.0572,0.141,0.007,40370.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-16",24,24,5683,,0.012,0.001,2257.992,0.0572,0.139,0.007,39770.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-17",24,24,6018,,0.013,0.001,2374.608,0.0568,0.146,0.007,41824.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-18",24,24,6050,,0.013,0.001,2392.296,0.0568,0.149,0.0071,42136.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-19",24,24,5203,,0.011,0.001,2097.096,0.0588,0.131,0.0071,36937.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-20",24,24,4503,,0.01,0.001,1856.808,0.0582,0.117,0.0072,32704.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-21",24,24,5925,,0.012,0.001,2349,0.0571,0.145,0.007,41374.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-22",24,24,5580,,0.012,0.001,2226.096,0.0586,0.137,0.007,39209.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-23",24,24,5736,,0.012,0.001,2284.392,0.0573,0.144,0.0072,40236.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-24",24,24,6063,,0.013,0.001,2395.608,0.0568,0.148,0.007,42195.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-25",24,24,5877,,0.012,0.001,2334.696,0.0572,0.147,0.0072,41122.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-26",24,24,5263,,0.011,0.001,2118.096,0.0583,0.131,0.007,37307.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-27",24,24,4379,,0.01,0.001,1819.992,0.0588,0.112,0.007,32056.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-28",24,23.2,5269.4,,0.011,0.001,2122.104,0.0606,0.136,0.0089,37378.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-29",12,11.32,2373.4,,0.005,0.001,973.497,0.0651,0.078,0.0193,17147.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-30",24,24,5200,,0.011,0.001,2120.592,0.0575,0.136,0.0073,37350.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-08-31",24,24,5237,,0.011,0.001,2144.592,0.0578,0.135,0.0072,37773,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-01",24,24,5377,,0.012,0.001,2203.2,0.0576,0.138,0.0072,38510.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-02",24,24,5498,,0.012,0.001,2246.088,0.0574,0.142,0.0073,39260.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-03",24,24,5601,,0.012,0.001,2277.504,0.0579,0.142,0.0072,39808.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-04",24,24,5657,,0.012,0.001,2269.704,0.058,0.141,0.0071,39672.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-05",24,24,4877,,0.01,0.001,1998.696,0.0591,0.124,0.0071,34934.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-06",24,24,5010,,0.011,0.001,2035.296,0.0588,0.129,0.0073,35573.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-07",24,24,5610,,0.012,0.001,2241.192,0.0583,0.141,0.0073,39173.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-08",24,24,5035,,0.011,0.001,2053.992,0.0589,0.134,0.0075,35900.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-09",24,24,4899,,0.011,0.001,2023.608,0.0586,0.131,0.0075,35370.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-10",15,14.07,2797.97,,0.006,0.001,1170.399,0.0621,0.105,0.0161,20457.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-11",12,11.02,2475.04,,0.005,0.001,1006.6,0.0668,0.091,0.0209,17594.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-12",24,24,5745,,0.012,0.001,2334.6,0.0574,0.143,0.007,40807,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-13",10,8.8,2054.89,,0.004,0.001,834.496,0.0698,0.081,0.0243,14587.117,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-14",11,9.83,2319.89,,0.005,0.001,943.897,0.0679,0.097,0.0232,16498.596,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-15",13,11.83,2801.91,,0.006,0.001,1130.403,0.0668,0.108,0.0202,19758.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-16",24,24,5823,,0.012,0.001,2359.992,0.0574,0.151,0.0073,41250.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-17",24,24,5822,,0.012,0.001,2359.008,0.0574,0.151,0.0073,41233.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-18",24,24,5625,,0.012,0.001,2283.792,0.0577,0.148,0.0074,39918.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-19",24,24,5705,,0.012,0.001,2329.008,0.0575,0.148,0.0073,40708.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-20",24,24,5532,,0.012,0.001,2272.392,0.0578,0.148,0.0075,39718.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-21",24,24,5774,,0.012,0.001,2346.288,0.0573,0.147,0.0072,41011.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-22",24,24,5602,,0.012,0.001,2286.408,0.0576,0.145,0.0073,39964.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-23",24,24,5621,,0.012,0.001,2291.4,0.0575,0.147,0.0073,40051.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-24",24,24,5661,,0.012,0.001,2303.208,0.0574,0.144,0.0072,40257.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-25",24,24,5577,,0.012,0.001,2272.992,0.0574,0.145,0.0073,39729.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-26",24,24,5782,,0.012,0.001,2356.296,0.0572,0.148,0.0072,41185.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-27",24,24,5376,,0.012,0.001,2211.192,0.0578,0.145,0.0076,38649.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-28",24,24,5065,,0.011,0.001,2092.392,0.0583,0.141,0.0078,36572.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-29",24,24,5670,,0.012,0.001,2286,0.0575,0.15,0.0076,39956.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-09-30",16,14.52,3482.24,,0.007,0.001,1388.199,0.0706,0.114,0.0184,24265.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-01",24,24,5752,,0.012,0.001,2294.208,0.0572,0.146,0.0073,40255.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-02",24,24,5858,,0.012,0.001,2353.392,0.057,0.149,0.0073,41294.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-03",24,24,5743,,0.012,0.001,2317.296,0.0572,0.147,0.0073,40661.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-04",20,18.92,4373.12,,0.009,0.001,1785.196,0.0622,0.142,0.012,31325.199,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-05",12,11.1,2666.6,,0.006,0.001,1081.695,0.123,0.133,0.0145,18980.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-06",24,24,5814,,0.012,0.001,2351.4,0.0572,0.242,0.0118,41260.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-07",24,24,5826,,0.012,0.001,2319.288,0.0573,0.153,0.0075,40696.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-08",24,24,5544,,0.012,0.001,2253.096,0.0573,0.15,0.0076,39535,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-09",24,24,5418,,0.012,0.001,2210.088,0.0574,0.145,0.0075,38780,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-10",24,24,5597,,0.012,0.001,2273.592,0.057,0.144,0.0073,39895.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-11",24,24,5370,,0.012,0.001,2215.992,0.0575,0.14,0.0073,38884.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-12",24,24,5326,,0.012,0.001,2196.288,0.0573,0.141,0.0073,38538,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-13",24,24,5592,,0.012,0.001,2261.688,0.0576,0.151,0.0077,39685.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-14",24,24,5753,,0.012,0.001,2287.704,0.0571,0.154,0.0077,40141.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-15",24,24,5913,,0.012,0.001,2336.208,0.057,0.154,0.0075,40993.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-16",24,24,5683,,0.012,0.001,2272.704,0.0571,0.162,0.0081,39878.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-17",24,24,5654,,0.012,0.001,2256.408,0.0572,0.164,0.0083,39593.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-18",24,24,5754,,0.012,0.001,2331.288,0.0572,0.165,0.0081,40907,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-19",24,24,5821,,0.012,0.001,2346.888,0.0571,0.166,0.008,41181.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-20",17,15.5,3767.9,,0.008,0.001,1517.001,0.0639,0.123,0.0145,26618.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-21",24,24,5751,,0.012,0.001,2331.792,0.0571,0.166,0.0081,40916.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-22",24,24,5813,,0.012,0.001,2316,0.0572,0.167,0.0082,40638.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-23",23,22.22,5306.14,,0.011,0.001,2116.81,0.06,0.154,0.0098,37144.094,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-29",13,12.55,2377.2,,0.005,0.001,1019.098,0.0729,0.248,0.0535,17881.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-30",21,20.4,4794.85,,0.01,0.001,1920.007,0.0607,0.151,0.0118,33689.233,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-10-31",24,24,5749,,0.012,0.001,2308.392,0.0572,0.166,0.0082,40504.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-01",24,24,5329,,0.011,0.001,2156.904,0.0579,0.157,0.0082,38273.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-02",24,24,5912,,0.013,0.001,2363.808,0.0564,0.172,0.0082,41945,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-03",24,24,5931,,0.013,0.001,2370.696,0.0564,0.176,0.0084,42067.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-04",24,24,5983,,0.013,0.001,2373.696,0.0564,0.173,0.0082,42120,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-05",24,24,5875,,0.012,0.001,2346.696,0.0565,0.168,0.0081,41641,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-06",24,24,5340,,0.011,0.001,2142.192,0.057,0.156,0.0083,38013.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-07",14,13.16,2981.01,,0.006,0.001,1201.205,0.058,0.105,0.0114,21315.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-08",24,24,5636,,0.012,0.001,2275.2,0.0565,0.168,0.0083,40372.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-09",24,24,5584,,0.012,0.001,2253.504,0.0565,0.169,0.0085,39988.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-10",24,24,5757,,0.012,0.001,2306.208,0.0565,0.166,0.0081,40923.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-11",24,24,5760,,0.012,0.001,2302.608,0.0565,0.167,0.0082,40858.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-12",24,24,5627,,0.012,0.001,2248.488,0.0568,0.159,0.008,39898.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-13",24,24,5633,,0.012,0.001,2255.592,0.0566,0.161,0.008,40024.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-14",24,24,5256,,0.011,0.001,2133.696,0.0572,0.151,0.008,37862.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-15",1,0.27,28.08,,0,0.001,12.9,0.057,0.004,0.038,228.015,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-16",19,16.99,3697.8,,0.008,0.001,1498.806,0.0977,0.161,0.0199,26595.244,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-17",24,24,5613,,0.012,0.001,2241.096,0.0568,0.163,0.0082,39766.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-18",24,24,5395,,0.012,0.001,2162.496,0.0568,0.157,0.0082,38373.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-19",20,19.25,4274.04,,0.009,0.001,1718.602,0.0587,0.147,0.011,30496.358,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-20",24,24,5800,,0.012,0.001,2298.192,0.0563,0.172,0.0085,40780.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-21",20,19.3,4444.85,,0.009,0.001,1775.001,0.0581,0.155,0.011,31496.285,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-22",16,15.46,3401.33,,0.007,0.001,1367.204,0.0595,0.125,0.0124,24259.751,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-23",20,18.75,4365.15,,0.009,0.001,1742.006,0.0634,0.15,0.0141,30910.515,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-24",20,18.66,4395.54,,0.009,0.001,1754.804,0.0648,0.146,0.0135,31137.649,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-25",20,19.25,4442.85,,0.009,0.001,1777.005,0.0582,0.148,0.0106,31531.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-26",24,24,5110,,0.011,0.001,2079.408,0.0578,0.157,0.0085,36898.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-27",20,18.8,4056.76,,0.009,0.001,1649.099,0.0627,0.146,0.0139,29262.596,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-28",19,17.8,4161.1,,0.009,0.001,1671.794,0.0637,0.15,0.0141,29665.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-29",18,16.5,3874.12,,0.008,0.001,1558.804,0.0677,0.14,0.0156,27660.558,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-11-30",20,19.01,4417.42,,0.009,0.001,1778.005,0.1952,0.157,0.0098,31549.606,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-01",24,24,5760,,0.012,0.001,2301.408,0.0565,0.173,0.0085,40787.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-02",24,24,5817,,0.012,0.001,2316.192,0.0565,0.174,0.0085,41049.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-03",24,24,5820,,0.012,0.001,2321.904,0.0563,0.173,0.0084,41151.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-04",24,24,5761,,0.012,0.001,2290.104,0.0566,0.172,0.0085,40587.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-05",24,24,5823,,0.012,0.001,2323.2,0.0565,0.175,0.0085,41173.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-06",24,24,5825,,0.012,0.001,2327.304,0.0565,0.171,0.0083,41245.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-07",24,24,5939,,0.013,0.001,2350.8,0.0565,0.17,0.0082,41663.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-08",24,24,5774,,0.012,0.001,2292.6,0.0566,0.17,0.0084,40631.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-09",24,24,5710,,0.012,0.001,2274.888,0.0565,0.17,0.0085,40317.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-10",24,24,5128,,0.011,0.001,2077.896,0.0576,0.157,0.0085,36825.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-11",24,24,5627,,0.012,0.001,2251.2,0.0568,0.164,0.0082,39897.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-12",24,24,5857,,0.012,0.001,2332.008,0.0565,0.171,0.0083,41330.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-13",16,14.55,3417,,0.007,0.001,1359.698,0.0674,0.12,0.0166,24098.285,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-14",24,24,5804,,0.012,0.001,2310.792,0.0566,0.174,0.0085,40954.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-15",24,24,5862,,0.012,0.001,2320.992,0.0565,0.175,0.0085,41134.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-16",24,24,5100,,0.011,0.001,2047.296,0.057,0.155,0.0085,36284,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-17",24,24,5388,,0.011,0.001,2158.488,0.0568,0.161,0.0084,38253.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-18",24,24,5491,,0.012,0.001,2200.8,0.0572,0.164,0.0085,39004.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-19",24,24,5835,,0.012,0.001,2323.104,0.0567,0.173,0.0084,41172.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-20",24,24,5653,,0.012,0.001,2258.808,0.0565,0.167,0.0083,40031.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-21",24,24,5788,,0.012,0.001,2315.496,0.0565,0.174,0.0085,41036.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-22",24,24,5766,,0.012,0.001,2312.496,0.0565,0.169,0.0083,40984.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-23",24,24,5629,,0.012,0.001,2246.304,0.0568,0.172,0.0087,39810.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-24",24,24,5929,,0.012,0.001,2346.792,0.0563,0.175,0.0084,41591.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-25",24,24,5811,,0.012,0.001,2301.288,0.0565,0.17,0.0083,40785.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-26",24,24,5817,,0.012,0.001,2307.792,0.0564,0.171,0.0083,40901.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-27",24,24,5775,,0.012,0.001,2299.2,0.0566,0.172,0.0085,40748.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-28",24,24,5890,,0.012,0.001,2335.392,0.0565,0.172,0.0083,41389.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-29",24,24,5759,,0.012,0.001,2301.288,0.0565,0.167,0.0082,40785.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-30",24,24,5758,,0.012,0.001,2293.392,0.0566,0.175,0.0086,40644.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"2A",,"2020-12-31",24,24,5767,,0.012,0.001,2301.6,0.0566,0.17,0.0083,40791.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-01",20,18.61,3963.8,,0.009,0.001,1617.395,0.063,0.116,0.0135,28765.511,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-02",20,18.32,4287.77,,0.009,0.001,1734.006,0.133,0.133,0.0098,30839.576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-03",21,19.45,4672.96,,0.01,0.001,1872.995,0.0683,0.133,0.0145,33310.614,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-04",19,18.04,4135.58,,0.009,0.001,1678.297,0.0614,0.119,0.0119,29849.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-05",19,17.75,4131.52,,0.009,0.001,1662.892,0.0632,0.122,0.0125,29574.495,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-06",20,18.6,4570.66,,0.01,0.001,1836.006,0.0647,0.13,0.0139,32653.128,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-07",24,24,5369,,0.012,0.001,2175,0.0568,0.135,0.007,38682.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-08",20,18.6,3895.6,,0.009,0.001,1597.293,0.0641,0.115,0.0133,28407.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-09",22,20.58,4704.44,,0.01,0.001,1909.701,0.064,0.132,0.0127,33963.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-10",21,19.54,4666.54,,0.01,0.001,1882.699,0.0669,0.133,0.0138,33483.029,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-11",20,18.83,3642.22,,0.008,0.001,1518.3,0.0609,0.11,0.0121,27002.966,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-12",19,16.81,3430.81,,0.008,0.001,1419.603,0.0673,0.108,0.0161,25247.416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-13",20,19.03,4483,,0.01,0.001,1809.791,0.641,0.123,0.0138,32187.443,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-14",19,17.58,3968.54,,0.009,0.001,1609.906,0.0654,0.115,0.0145,28631.812,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-15",19,16.03,3739.91,,0.008,0.001,1511.1,0.1419,0.132,0.0169,26875.231,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-16",19,17.77,4089.9,,0.009,0.001,1647.296,0.0632,0.12,0.0128,29297.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-17",20,18.78,4384.2,,0.009,0.001,1760.1,0.0631,0.126,0.0121,31303.218,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-18",19,17.58,4252.96,,0.009,0.001,1695.995,0.0653,0.122,0.0135,30162.716,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-19",24,24,5569,,0.012,0.001,2241.696,0.0572,0.14,0.007,39868.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-20",22,20.55,4937.8,,0.011,0.001,1971.998,0.0642,0.139,0.0126,35072.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-21",18,14.86,3134.45,,0.007,0.001,1272.997,0.1422,0.118,0.0171,22640.341,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-22",24,24,5701,,0.012,0.001,2278.704,0.0563,0.142,0.007,40526.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-23",24,24,5718,,0.012,0.001,2277.6,0.0563,0.142,0.007,40506.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-24",19,17.53,3727.23,,0.008,0.001,1513.996,0.0646,0.109,0.0119,26927.305,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-25",11,9.64,2220.98,,0.005,0.001,908.696,0.0712,0.077,0.0185,16160.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-26",9,6.89,1438.13,,0.003,0.001,600.601,0.0772,0.058,0.026,10681.644,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-27",17,15.23,2972.72,,0.007,0.001,1249.194,0.0652,0.103,0.0176,22217.745,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-28",19,17.27,3584.41,,0.008,0.001,1482.992,0.133,0.11,0.0098,26375.665,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-29",19,17.82,4235.71,,0.009,0.0009,1709.098,0.1674,0.128,0.0083,30396.711,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-30",19,17.27,4016.47,,0.009,0.001,1623,0.0624,0.122,0.0127,28865.851,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-01-31",17,14.85,3194.88,,0.007,0.001,1311.597,0.1343,0.118,0.0136,23326.719,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-01",19,17.56,4266.24,,0.009,0.001,1718.491,0.0669,0.124,0.0146,30512.644,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-02",24,24,5560,,0.012,0.001,2232.792,0.0566,0.14,0.0071,39645.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-03",19,17.73,4264.62,,0.009,0.001,1708.693,0.0644,0.123,0.0127,30339.933,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-04",21,20.06,4837.52,,0.01,0.001,1943.192,0.0618,0.137,0.0118,34502.796,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-05",21,19.85,4748.64,,0.01,0.001,1911.297,0.0615,0.135,0.0117,33936.801,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-06",19,17.83,4091.09,,0.009,0.001,1648.294,0.0622,0.117,0.012,29267.749,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-07",19,17.83,3892.49,,0.008,0.001,1594.091,0.0635,0.119,0.0127,28304.993,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-08",17,15.88,3651.72,,0.008,0.001,1475.395,0.0631,0.113,0.0133,26197.722,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-09",24,24,5773,,0.012,0.001,2297.088,0.0563,0.143,0.007,40787.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-10",24,24,5738,,0.012,0.001,2286.6,0.0566,0.142,0.007,40600.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-11",19,17.62,4112.9,,0.009,0.001,1658.905,0.0651,0.12,0.0136,29454.557,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-12",19,17.56,4009.34,,0.009,0.001,1624.897,0.0672,0.118,0.0148,28850.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-13",19,17.56,4240.66,,0.009,0.001,1708.096,0.0672,0.122,0.0148,30329.024,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-14",17,15.53,3782.56,,0.008,0.001,1510.805,0.0675,0.115,0.0149,26826.014,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-15",19,17.56,4101.64,,0.009,0.001,1649.603,0.0662,0.12,0.0135,29289.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-16",10,8.51,1979.57,,0.004,0.001,797.403,0.0737,0.068,0.0188,14159.096,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-17",19,17.52,3765.53,,0.008,0.001,1542.005,0.0682,0.114,0.0156,27380.554,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-18",21,19.81,4648.73,,0.01,0.001,1877.097,0.0627,0.136,0.0119,33329.488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-19",19,17.54,4224.56,,0.009,0.001,1704.397,0.0687,0.123,0.0153,30262.364,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-20",19,17.58,4083.84,,0.009,0.001,1657.496,0.0671,0.12,0.0143,29430.026,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-21",20,19.33,4671.17,,0.01,0.001,1874.101,0.0612,0.133,0.0118,33276.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-22",11,9.98,2092.94,,0.005,0.001,870.595,0.065,0.073,0.0165,15458.469,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-23",11,9.71,2059.69,,0.005,0.001,851.897,0.0695,0.069,0.0177,15125.922,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-24",17,15.78,3592.46,,0.008,0.001,1455.295,0.0648,0.107,0.0129,25840.608,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-25",19,17.85,4142.25,,0.009,0.001,1677.793,0.0617,0.119,0.0116,29791.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-26",18,16.53,3880.94,,0.008,0.001,1563.192,0.0671,0.113,0.0141,27756.196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-27",18,16.51,4015,,0.009,0.001,1607.793,0.067,0.117,0.0138,28548.332,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-28",18,14.69,3077.05,,0.007,0.0009,1255.305,0.1297,0.117,0.0202,22288.871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-02-29",10,8.6,1828.64,,0.004,0.001,760.498,0.0716,0.071,0.021,13503.442,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-01",18,16.82,3931.79,,0.008,0.001,1597.496,0.0614,0.115,0.0122,28131.868,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-02",19,18.1,4058.98,,0.009,0.001,1652.295,0.0622,0.12,0.0118,29096.488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-03",18,16.42,3975.82,,0.008,0.001,1599.505,0.0751,0.119,0.0137,28168.405,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-04",20,19.4,4407.45,,0.01,0.001,1798.594,0.0619,0.131,0.0117,31673.53,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-05",20,18.8,3872.44,,0.008,0.001,1607.005,0.0635,0.115,0.0121,28298.958,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-06",20,18.84,4367.83,,0.009,0.001,1782.602,0.0635,0.128,0.0121,31391.566,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-07",24,24,5576,,0.012,0.001,2274.408,0.0579,0.144,0.0072,40053.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-08",19,17.84,4201.73,,0.009,0.001,1713.194,0.0629,0.121,0.0122,30169.843,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-09",22,20.61,4794.71,,0.01,0.001,1946.594,0.0639,0.135,0.0123,34280.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-10",24,24,5397,,0.012,0.001,2195.688,0.0588,0.137,0.0071,38666.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-11",19,17.32,4317.42,,0.009,0.0009,1735.29,0.1625,0.134,0.0099,30559.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-12",21,19.64,4812.54,,0.01,0.001,1946.697,0.0624,0.136,0.012,34281.829,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-13",19,18.05,4432.61,,0.009,0.001,1777.69,0.0639,0.141,0.0131,31306.427,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-14",18,15.18,3333.47,,0.007,0.001,1383.795,0.0769,0.12,0.0177,24369.023,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-15",17,16.23,3904.01,,0.008,0.001,1572.703,0.0614,0.114,0.0105,27695.185,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-16",24,24,5308,,0.011,0.001,2162.4,0.0588,0.135,0.0071,38079.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-17",19,17.8,4189.14,,0.009,0.001,1706.397,0.0628,0.122,0.0125,30050.256,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-18",22,20.6,4770.34,,0.01,0.001,1940.602,0.064,0.135,0.0125,34174.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-19",19,17.84,4181.3,,0.009,0.001,1695.192,0.0636,0.125,0.0127,29853.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-20",21,19.56,4330.8,,0.009,0.001,1772.194,0.066,0.124,0.0136,31209.536,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-21",19,17.81,4238.3,,0.009,0.001,1721.194,0.0629,0.122,0.0123,30311.256,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-22",19,17.81,4283.38,,0.009,0.001,1732.592,0.063,0.123,0.0123,30511.782,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-23",20,18.87,4241.82,,0.009,0.001,1731.191,0.062,0.12,0.0113,30486.951,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-24",19,17.5,3905.24,,0.008,0.001,1588.195,0.0673,0.112,0.0136,27968.339,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-25",19,17.51,3935.11,,0.008,0.001,1605.194,0.0667,0.114,0.0138,28268.405,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-26",17,16,3762.95,,0.008,0.001,1516.897,0.0652,0.111,0.0129,26712.479,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-27",20,18.79,4167.14,,0.009,0.001,1703.802,0.0622,0.12,0.0118,30003.545,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-28",19,17.79,4132.3,,0.009,0.001,1680.496,0.0619,0.121,0.0118,29593.681,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-29",13,11.72,2406.42,,0.005,0.001,999.903,0.0652,0.078,0.0149,17607.694,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-30",22,20.55,4370.58,,0.01,0.001,1804.906,0.0661,0.133,0.0137,31784.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-03-31",18,16.74,3317.56,,0.007,0.001,1372.495,0.0631,0.099,0.0124,24169.932,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-01",22,20.56,4192.8,,0.009,0.001,1738.492,0.0719,0.131,0.0114,30677.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-02",21,18.99,3833.12,,0.008,0.001,1594.894,0.0651,0.12,0.0139,28142.669,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-03",10,9.4,2053.2,,0.005,0.001,852.496,0.0659,0.067,0.0154,15043.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-04",24,24,5472,,0.012,0.001,2233.008,0.0578,0.146,0.0075,39403.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-05",24,24,6118,,0.013,0.001,2456.592,0.0568,0.163,0.0075,43350.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-06",24,24,6002,,0.013,0.001,2410.104,0.0569,0.154,0.0073,42529.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-07",24,23.2,5363.8,,0.011,0.001,2154.305,0.0612,0.139,0.0091,38014.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-08",21,20.37,5059.62,,0.011,0.001,2020.806,0.0611,0.144,0.0114,35658.739,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-09",24,24,5991,,0.013,0.001,2384.808,0.057,0.155,0.0074,42081.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-10",24,24,5775,,0.012,0.001,2309.904,0.0571,0.148,0.0073,40760.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-11",6,4.95,965.05,,0.002,0.001,412.102,0.071,0.046,0.025,7271.568,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-12",17,15.6,3577.96,,0.008,0.001,1471.704,0.0662,0.109,0.0138,25969.896,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-13",20,18.52,3799.13,,0.008,0.001,1575.089,0.067,0.113,0.0148,27793.749,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-14",11,9.6,1977.1,,0.004,0.001,826.896,0.0748,0.072,0.0213,14590.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-15",20,17.75,3521.2,,0.008,0.001,1469.806,0.0686,0.11,0.0163,25936.181,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-16",10,8.6,1953.26,,0.004,0.001,806.103,0.0734,0.078,0.0216,14224.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-17",21,19.6,4533.74,,0.01,0.001,1853.395,0.0645,0.133,0.0131,32704.822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-20",11,10.45,1684.6,,0.004,0.001,753.602,0.0657,0.092,0.0243,13298.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-21",10,9.22,1487.46,,0.003,0.001,646.903,0.0602,0.043,0.0102,11415.746,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-22",1,0.28,3.92,,0,0.001,4.6,0.057,0.003,0.074,81.256,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-23",10,9.63,1999.82,,0.004,0.001,839.197,0.0652,0.071,0.0147,14808.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-24",15,13.45,2866.8,,0.006,0.001,1176.7,0.0721,0.094,0.0171,20764.755,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-25",20,18.95,4478.25,,0.01,0.001,1817.703,0.0605,0.126,0.0099,32075.822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-26",12,10.6,2156.75,,0.005,0.001,903.003,0.0705,0.073,0.0183,15934.525,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-27",20,18.52,3190.13,,0.007,0.001,1379.295,0.0642,0.101,0.0145,24339.003,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-28",21,19.53,4121.06,,0.009,0.001,1705.203,0.0662,0.121,0.0142,30089.167,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-29",21,18.71,3523.13,,0.008,0.001,1482.095,0.0675,0.107,0.0154,26153.025,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-04-30",18,16.6,2544.5,,0.006,0.001,1128.8,0.0628,0.084,0.0141,19917.882,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-01",7,5.55,1030.25,,0.002,0.001,429.398,0.0733,0.043,0.0251,7571.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-02",9,6.91,1306.2,,0.003,0.001,558.701,0.1008,0.059,0.0461,9852.855,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-03",13,10.74,1481.15,,0.004,0.001,678.897,0.0675,0.061,0.0211,11971.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-04",19,18.3,4237,,0.009,0.001,1705.505,0.063,0.129,0.0125,30075.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-05",19,17.45,3855.72,,0.008,0.001,1563.503,0.0682,0.118,0.0156,27570.61,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-06",10,9.38,1880.6,,0.004,0.001,787.498,0.0657,0.069,0.0166,13887.846,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-07",22,20.54,4035.57,,0.009,0.001,1690.689,0.0663,0.117,0.0135,29815.243,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-08",19,17.81,3877.62,,0.008,0.001,1584.199,0.0614,0.12,0.0127,27936.401,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-20",22,21.12,3261,,0.008,0.001,1451.789,0.067,0.134,0.0144,25601.376,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-21",19,17.23,3191.86,,0.007,0.001,1352.693,0.1615,0.098,0.0099,23853.906,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-22",17,16.05,2946.66,,0.007,0.001,1251.9,0.0606,0.106,0.0116,22076.766,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-23",8,6.45,1378.85,,0.003,0.001,564.698,0.0809,0.058,0.0251,9957.655,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-24",8,7.45,1578.75,,0.003,0.001,647.8,0.0695,0.058,0.0199,11424.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-25",21,19.07,3785.27,,0.008,0.001,1576.097,0.0676,0.121,0.015,27794.406,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-26",21,20.37,4496.36,,0.01,0.001,1831.996,0.0612,0.13,0.0117,32307.036,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-27",24,23.98,5150.58,,0.011,0.001,2113.19,0.0583,0.138,0.0074,37265.442,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-28",13,11.48,2630.8,,0.006,0.001,1061.2,0.0726,0.086,0.0178,18713.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-29",17,15.59,3197.66,,0.007,0.001,1315.297,0.0659,0.102,0.0149,23194.273,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-30",8,7.28,1221.04,,0.003,0.001,521.998,0.0666,0.047,0.0184,9204.608,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-05-31",9,7.98,1401.08,,0.003,0.001,592.196,0.0652,0.055,0.0164,10442.386,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-01",14,12.39,2745.54,,0.006,0.001,1125.198,0.0638,0.09,0.0148,19829.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-02",15,14.27,3433.61,,0.007,0.001,1365.197,0.0647,0.098,0.0129,24058.659,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-03",21,19.6,4486.11,,0.01,0.001,1805.101,0.0647,0.126,0.0132,31809.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-04",20,18.3,4070.76,,0.009,0.001,1647.805,0.0663,0.12,0.0141,29038.135,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-05",16,14.54,2435.27,,0.006,0.001,1043.201,0.0645,0.078,0.0158,18383.859,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-06",12,10.54,1517.98,,0.004,0.001,671.198,0.0661,0.056,0.0194,11828.846,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-07",13,11.54,1635.04,,0.004,0.001,740.199,0.0651,0.062,0.0182,13043.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-08",11,10.78,2105.82,,0.005,0.001,892.303,0.0642,0.079,0.0162,15724.644,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-09",19,16.84,3892.71,,0.008,0.001,1585.992,0.0683,0.118,0.016,27949.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-10",11,10.15,2424.81,,0.005,0.001,992.101,0.0668,0.081,0.0158,17484.327,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-11",11,10.11,2363.87,,0.005,0.001,962.199,0.0659,0.078,0.0155,16955.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-12",19,18.3,3777.61,,0.008,0.001,1575.996,0.0609,0.117,0.012,27772.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-13",12,10.52,1499.76,,0.004,0.001,677.204,0.0647,0.056,0.0191,11934.91,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-14",20,17.99,3171.31,,0.007,0.001,1367.599,0.0678,0.114,0.0175,24100.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-15",11,9.54,2104.46,,0.005,0.001,869.504,0.0753,0.068,0.0201,15323.162,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-16",13,11.85,2685.05,,0.006,0.001,1105.096,0.0646,0.088,0.0146,19474.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-17",23,22.68,4074.56,,0.009,0.001,1733.409,0.0583,0.112,0.0074,30547.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-18",16,15.06,2809.94,,0.006,0.001,1183.701,0.0618,0.098,0.0138,20859.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-19",17,15.62,3726.82,,0.008,0.001,1505.799,0.0677,0.115,0.0149,26535.508,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-20",10,9.4,2057.4,,0.004,0.001,847.899,0.0658,0.085,0.0228,14943,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-21",16,13.73,2630.58,,0.006,0.001,1104.303,0.0727,0.091,0.0221,19460.446,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-22",11,9.81,2386.95,,0.005,0.001,961.998,0.0688,0.089,0.021,16952.816,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-23",10,8.9,2079.12,,0.004,0.001,844.601,0.0658,0.073,0.0204,14883.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-24",11,10.12,2423.13,,0.005,0.001,979.302,0.0654,0.083,0.0192,17258.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-25",10,8.64,1990.94,,0.004,0.001,813.101,0.0701,0.072,0.0225,14327.991,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-29",12,10.73,1795.39,,0.004,0.001,793.398,0.0734,0.138,0.0356,13981.798,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-06-30",5,4.29,833.23,,0.002,0.001,355.8,0.0682,0.043,0.0296,6270.326,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-01",8,6.52,1230.52,,0.003,0.001,533.298,0.0703,0.091,0.0333,9358.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-03",10,9.9,2253,,0.005,0.001,945.499,0.0639,0.09,0.0182,16590.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-04",11,9.43,2127.65,,0.005,0.001,882.402,0.0668,0.077,0.0179,15482.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-05",11,9.71,2249.86,,0.005,0.001,927.703,0.0748,0.076,0.0214,16277.443,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-06",13,11.5,2607.6,,0.006,0.001,1059.898,0.0728,0.09,0.0202,18598.028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-07",13,11.55,2477.75,,0.005,0.001,1031.6,0.0696,0.084,0.0189,18101.814,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-08",12,10.58,2484.01,,0.005,0.001,1019.404,0.0705,0.087,0.0196,17886.937,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-09",11,9.64,2280.93,,0.005,0.001,927.204,0.0705,0.079,0.0199,16268.565,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-10",13,11.48,2784.48,,0.006,0.001,1124.099,0.0735,0.094,0.0198,19724.716,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-11",12,11.05,2695.79,,0.006,0.001,1087.994,0.068,0.094,0.0175,19090.304,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-12",13,11.84,2839.08,,0.006,0.001,1147.296,0.0675,0.097,0.017,20130.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-13",13,11.46,2430.64,,0.005,0.001,1000.997,0.0718,0.079,0.0196,17564.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-14",11,9.45,2130.98,,0.005,0.001,871.8,0.0791,0.071,0.0232,15297.456,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-15",10,8.45,1729.94,,0.004,0.001,717.701,0.0782,0.062,0.0246,12594.027,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-16",10,8.46,1575.9,,0.004,0.001,669,0.0761,0.059,0.0237,11739.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-17",8,7.33,1627.55,,0.004,0.001,668.599,0.0706,0.063,0.0206,11731.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-18",11,10.18,2394.21,,0.005,0.001,982.899,0.0657,0.086,0.0172,17247.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-19",13,11.62,2253.48,,0.005,0.001,957.895,0.0697,0.079,0.0195,16807.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-20",12,11.28,2573.48,,0.006,0.001,1048.104,0.0668,0.084,0.0161,18391.332,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-21",23,22.27,5151.46,,0.011,0.001,2096.988,0.06,0.134,0.0086,36795.556,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-22",8,7.13,1625.53,,0.003,0.001,662.599,0.0655,0.059,0.0184,11625.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-23",7,5.94,1324.22,,0.003,0.001,542.899,0.0681,0.053,0.0221,9526.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-24",7,6.06,1417.39,,0.003,0.001,574.798,0.072,0.059,0.023,10085.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-25",11,10.23,2381.54,,0.005,0.001,981.701,0.0637,0.081,0.016,17226.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-26",12,11.34,2711.8,,0.006,0.001,1114.302,0.0634,0.087,0.0153,19553.038,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-27",20,19.42,4453.4,,0.01,0.001,1832.491,0.0624,0.125,0.0116,32153.848,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-28",21,19.26,4635.91,,0.01,0.001,1866.197,0.0658,0.137,0.0141,32745.409,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-29",14,13.33,3335.19,,0.007,0.001,1339.905,0.0654,0.097,0.0143,23511.394,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-30",17,15.35,3724.45,,0.008,0.001,1503.102,0.0763,0.107,0.0178,26375.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-07-31",15,14.28,3137.64,,0.007,0.001,1276.404,0.063,0.096,0.0144,22397.117,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-01",16,14.45,3104.18,,0.007,0.001,1262.193,0.0755,0.092,0.0203,22232.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-02",13,10.74,2504.72,,0.005,0.001,1024.402,0.0897,0.081,0.0263,18042.43,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-03",12,10.48,2209.67,,0.005,0.001,900.295,0.0776,0.075,0.0223,15857.965,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-04",7,5.83,1322.02,,0.003,0.001,545.402,0.0729,0.055,0.0237,9605.876,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-05",8,6.81,1510.49,,0.003,0.001,614.698,0.0704,0.059,0.0216,10827.569,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-06",20,18.59,4004.09,,0.009,0.001,1674.996,0.0652,0.127,0.0152,29502.829,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-07",7,6.05,1383.19,,0.003,0.001,569.002,0.072,0.068,0.0266,10022.535,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-08",9,8.37,1942.39,,0.004,0.001,796.899,0.0673,0.079,0.021,14035.732,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-09",17,15.57,3331.34,,0.007,0.001,1387.194,0.0703,0.113,0.0172,24434.059,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-10",13,10.71,2350.71,,0.005,0.001,973.1,0.0775,0.092,0.0247,17138.736,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-11",13,12.31,2667.87,,0.006,0.001,1098.2,0.0653,0.1,0.0176,19343.538,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-12",17,16.05,3738.2,,0.008,0.001,1519.902,0.0631,0.125,0.0154,26770.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-13",20,19.33,4824.48,,0.01,0.001,1927.298,0.0614,0.144,0.0121,33945.719,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-14",23,22.2,5254.6,,0.011,0.001,2103.605,0.0616,0.152,0.0105,37050.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-15",18,17.42,4087.76,,0.009,0.001,1651.294,0.0616,0.133,0.0143,29084.586,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-16",24,23.2,5358.2,,0.011,0.001,2150.199,0.0608,0.156,0.0103,37872.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-17",18,16.41,3989.02,,0.008,0.001,1604.701,0.1627,0.149,0.0114,28264.343,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-18",21,20.25,5052.25,,0.011,0.001,2012.303,0.063,0.156,0.0133,35444.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-19",24,23.13,5274.46,,0.011,0.001,2124.005,0.0646,0.153,0.0123,37411.639,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-20",17,15.55,2776.5,,0.006,0.001,1176.093,0.0684,0.117,0.0212,20715.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-21",21,20.32,4964,,0.01,0.001,1978.497,0.0617,0.153,0.0135,34848.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-22",24,23.23,5866.85,,0.012,0.001,2329.69,0.0593,0.168,0.0098,41034.745,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-23",16,15.4,3597.6,,0.008,0.001,1452.697,0.0624,0.117,0.0149,25586.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-24",22,20.53,4953.71,,0.01,0.001,1979.502,0.0663,0.158,0.0156,34866.639,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-25",22,19.66,4634.18,,0.01,0.001,1856.593,0.0734,0.157,0.0205,32701.366,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-26",17,16.4,3387,,0.007,0.001,1397.198,0.0623,0.117,0.0149,24609.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-27",24,23.13,4042.07,,0.009,0.001,1704.403,0.0631,0.124,0.0121,30020.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-28",12,11.33,2633.18,,0.006,0.001,1059.695,0.0652,0.092,0.0175,18665.642,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-29",17,14.65,3150.61,,0.007,0.001,1290.401,0.0754,0.109,0.0236,22728.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-30",14,12.55,2580.73,,0.006,0.001,1082.6,0.0732,0.096,0.0231,19068.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-08-31",11,9.33,1867.73,,0.004,0.001,780.996,0.1144,0.084,0.0159,13756.859,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-01",9,7.5,1510.2,,0.003,0.001,633.502,0.0774,0.066,0.0283,11072.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-02",7,5.59,1118.92,,0.002,0.001,468.302,0.0811,0.057,0.0349,8184.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-03",15,13.56,3131.49,,0.007,0.001,1277.596,0.0697,0.108,0.0186,22331.291,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-04",17,16.42,3878.06,,0.008,0.001,1588.306,0.0614,0.125,0.0134,27761.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-05",24,24,4681,,0.01,0.001,1956.888,0.0591,0.138,0.008,34204.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-06",24,24,4859,,0.011,0.001,2008.992,0.0592,0.14,0.008,35115.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-07",24,24,5572,,0.012,0.001,2257.296,0.0581,0.159,0.008,39456,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-08",24,23.13,4777.42,,0.01,0.001,1979.303,0.0658,0.142,0.0124,34596.267,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-09",12,10.46,1720.07,,0.004,0.001,748.497,0.0736,0.071,0.0263,13083.019,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-10",12,10.55,1837.82,,0.004,0.001,798.899,0.0755,0.075,0.026,13964.477,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-11",9,7.65,1610.04,,0.004,0.001,679.496,0.0759,0.068,0.0269,11877.594,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-12",13,11.69,2680.89,,0.006,0.001,1110.398,0.0682,0.099,0.0198,19409.299,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-13",8,6.93,1533.22,,0.003,0.001,645.703,0.0659,0.066,0.0216,11286.601,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-14",11,9.6,2215,,0.005,0.001,920.4,0.0725,0.085,0.0229,16087.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-15",12,10.59,2435.67,,0.005,0.001,1004.398,0.0711,0.093,0.0218,17555.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-16",12,10.54,2478.16,,0.005,0.001,1010.996,0.0717,0.096,0.0216,17671.768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-17",14,13.4,3189.8,,0.007,0.001,1305.897,0.0624,0.105,0.0148,22825.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-18",14,12.98,2911.14,,0.006,0.001,1192.797,0.0651,0.114,0.0176,20849.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-19",18,16.88,3941.88,,0.009,0.001,1636.803,0.062,0.135,0.0148,28610.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-20",9,8.58,1999.46,,0.004,0.001,823.302,0.0678,0.101,0.0252,14389.718,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-21",18,15.77,3666.62,,0.008,0.001,1498.292,0.0702,0.131,0.0192,26187.996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-22",10,8.63,1847.05,,0.004,0.001,775.897,0.0794,0.08,0.0289,13561.352,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-23",15,13.68,3042.24,,0.007,0.001,1257.301,0.061,0.085,0.0129,21976.132,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-27",14,12.97,2604.73,,0.006,0.001,1123.098,0.068,0.143,0.0261,19630.157,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-28",20,18.82,3846.34,,0.008,0.001,1604.593,0.062,0.132,0.0142,28046.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-29",18,16.72,3844.16,,0.008,0.001,1570.894,0.0671,0.139,0.0186,27458.532,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-09-30",24,23.25,5516.75,,0.012,0.001,2219.189,0.06,0.16,0.0097,38789.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-01",20,18.59,4233.86,,0.009,0.001,1705.707,0.0902,0.135,0.0141,29929.084,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-02",20,18.88,4505.4,,0.01,0.001,1828.207,0.061,0.151,0.0143,32080.328,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-03",12,10.22,2456.89,,0.005,0.0009,997.002,0.1597,0.109,0.0175,17493.416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-04",9,7.56,1732.38,,0.004,0.001,722.902,0.0789,0.081,0.0284,12685.588,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-05",21,20.4,4913.2,,0.011,0.001,2018.498,0.0611,0.163,0.0139,35419.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-06",24,24,5882,,0.013,0.001,2375.208,0.0571,0.169,0.0081,41678.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-07",24,24,5945,,0.012,0.001,2374.008,0.057,0.168,0.0081,41656.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-08",21,18.77,4276.2,,0.009,0.001,1743.301,0.1139,0.153,0.0121,30590.249,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-09",15,13.55,2984.54,,0.007,0.001,1239.202,0.0732,0.106,0.0218,21744.093,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-11",20,19.97,4074.22,,0.009,0.001,1732.597,0.0603,0.166,0.0146,30401.77,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-12",23,22.47,4962.08,,0.011,0.001,2060.791,0.0582,0.153,0.009,36160.856,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-13",20,19.07,4222.35,,0.009,0.001,1722.993,0.1016,0.147,0.0141,30232.934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-14",19,17.45,4235.57,,0.009,0.001,1686.595,0.0722,0.143,0.0197,29594.995,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-15",19,16.71,4014.49,,0.008,0.001,1608.303,0.0724,0.138,0.0208,28221.364,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-16",18,17.4,3967.8,,0.009,0.001,1619.992,0.061,0.132,0.0143,28426.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-17",21,19.75,4456.17,,0.009,0.001,1798,0.0628,0.151,0.0149,31549.707,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-18",17,16,3733.11,,0.008,0.001,1517.296,0.0591,0.139,0.0124,26623.426,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-19",19,16.61,3924.7,,0.008,0.001,1604.195,0.1334,0.172,0.0155,28148.152,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-20",20,18.01,4290.18,,0.009,0.001,1744.197,0.0673,0.147,0.0168,30606.099,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-21",13,12.5,2925,,0.006,0.001,1204.6,0.0633,0.111,0.0173,21136.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-22",21,19.57,4655.99,,0.01,0.001,1873.593,0.0892,0.16,0.0119,32875.866,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-23",24,24,5677,,0.012,0.001,2282.904,0.057,0.163,0.0081,40057.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-24",24,23.22,5652.38,,0.012,0.001,2303.494,0.0605,0.168,0.0102,40419.334,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-25",12,11.48,2669.92,,0.006,0.001,1105.604,0.0633,0.096,0.0168,19400.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-26",24,24,5780,,0.012,0.001,2340,0.0573,0.168,0.0082,41060.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-27",21,18.95,4359.37,,0.009,0.001,1775.691,0.0667,0.155,0.0175,31157.957,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-28",17,16.42,3848.7,,0.008,0.001,1553.003,0.0614,0.13,0.0154,27250.544,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-29",24,24,5997,,0.013,0.001,2393.688,0.0571,0.17,0.0081,42001.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-30",21,19.54,4601.72,,0.01,0.001,1878.204,0.0617,0.17,0.0142,32956.519,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-05",8,7.03,1558.06,,0.003,0.001,643.203,0.3228,0.113,0.0286,11413.684,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-06",21,19.54,4389.7,,0.009,0.001,1774.389,0.0646,0.143,0.0148,31486.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-07",24,23.45,5223.6,,0.011,0.001,2119.388,0.0578,0.16,0.009,37608.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-08",9,7.85,1818.15,,0.004,0.001,741.001,0.0683,0.083,0.0233,13149.145,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-09",17,15.1,3421.4,,0.007,0.001,1398.803,0.0684,0.16,0.0238,24821.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-10",21,19.58,4711.38,,0.01,0.001,1904.801,0.0715,0.168,0.0143,33800.933,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-11",20,18.54,4449.02,,0.01,0.001,1790.594,0.1108,0.163,0.0115,31773.775,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-12",20,18.58,4342.2,,0.009,0.001,1753.098,0.0656,0.142,0.0161,31108.336,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-13",18,15.75,3561.73,,0.008,0.001,1446.101,0.0722,0.125,0.0212,25660.61,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-14",11,10.48,2386.48,,0.005,0.001,981.997,0.0634,0.087,0.0173,17425.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-15",11,9.92,2304.32,,0.005,0.001,941.795,0.0656,0.092,0.0191,16712.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-16",12,10.83,2401.81,,0.005,0.001,982.899,0.0693,0.093,0.0199,17441.083,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-17",20,18.5,4444.94,,0.01,0.001,1786.896,0.0671,0.142,0.0167,31708.172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-18",19,18.26,4229.6,,0.009,0.001,1696.098,0.0578,0.143,0.011,30096.858,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-19",20,18.52,3976.92,,0.009,0.001,1628.797,0.066,0.134,0.0174,28902.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-20",21,19.55,4673.05,,0.01,0.001,1865.188,0.0646,0.149,0.0138,33097.958,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-21",11,10.13,2330.02,,0.005,0.001,943.397,0.0641,0.088,0.0193,16740.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-22",11,9.1,1972.14,,0.004,0.001,824.597,0.0742,0.091,0.0276,14632.883,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-23",17,14.73,3340.44,,0.007,0.001,1359.696,0.07,0.125,0.0206,24127.691,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-24",20,18.62,4396.22,,0.009,0.001,1778.098,0.0704,0.149,0.0139,31552.158,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-25",19,17.58,4154.62,,0.009,0.001,1682.899,0.0654,0.136,0.0161,29862.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-26",17,14.24,3058.09,,0.007,0.001,1257.604,0.0765,0.127,0.025,22315.701,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-27",18,16.63,3664.19,,0.008,0.001,1507.692,0.0637,0.124,0.0156,26753.399,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-28",11,9.88,2277.62,,0.005,0.001,935.597,0.0652,0.089,0.0195,16601.438,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-29",18,16.61,3970.31,,0.009,0.001,1629.889,0.0642,0.131,0.0148,28921.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-11-30",20,18.62,4474.62,,0.01,0.001,1817.796,0.0649,0.149,0.016,32256.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-01",20,18.77,4552,,0.01,0.001,1839.798,0.0674,0.161,0.0155,32607.331,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-02",21,19.6,4737.55,,0.01,0.001,1904.904,0.1009,0.161,0.0107,33760.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-03",21,19.57,4808.52,,0.01,0.001,1929.798,0.0634,0.153,0.0148,34201.124,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-04",24,24,5886,,0.013,0.001,2352.288,0.0565,0.167,0.008,41690.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-05",20,18.72,4540.96,,0.01,0.001,1831.003,0.0636,0.148,0.0148,32450.953,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-06",20,18.64,4512.3,,0.01,0.001,1818.892,0.0651,0.147,0.016,32235.807,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-07",24,24,5964,,0.013,0.001,2373.6,0.0565,0.168,0.008,42066.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-08",17,15.65,3594.3,,0.008,0.001,1451.991,0.0636,0.122,0.0168,25734.252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-09",24,24,5403,,0.012,0.001,2176.8,0.0569,0.154,0.008,38579,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-10",24,24,5238,,0.011,0.001,2128.104,0.0575,0.152,0.0081,37716.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-11",24,24,5559,,0.012,0.001,2239.104,0.0571,0.16,0.008,39683.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-12",17,15.6,3688.72,,0.008,0.001,1494.199,0.0659,0.124,0.017,26480.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-13",24,24,5844,,0.012,0.001,2338.896,0.0565,0.167,0.008,41451.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-14",24,24,5740,,0.012,0.001,2302.008,0.0568,0.165,0.0081,40797.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-15",22,20.59,5009.37,,0.011,0.001,2005.795,0.0644,0.16,0.0153,35548.115,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-16",24,24,5584,,0.012,0.001,2240.808,0.057,0.159,0.008,39712.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-17",20,18.63,4400.59,,0.009,0.001,1778.495,0.0649,0.144,0.0162,31520.864,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-18",22,20.46,4878,,0.01,0.001,1955.198,0.0661,0.164,0.0163,34651.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-19",19,17.61,4245.59,,0.009,0.001,1714.598,0.0648,0.147,0.0194,30386.901,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-20",20,18.63,4298.93,,0.009,0.001,1744.103,0.0631,0.147,0.0176,30909.919,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-21",24,24,5967,,0.013,0.001,2391.696,0.0566,0.17,0.008,42387.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-22",20,18.89,4536.7,,0.01,0.001,1838.601,0.062,0.158,0.0181,32585.254,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-23",21,19.82,4753.56,,0.01,0.001,1904.999,0.0629,0.15,0.0131,33762.562,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-24",24,24,6066,,0.013,0.001,2416.488,0.0564,0.171,0.008,42827.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-25",20,18.77,4486.52,,0.01,0.001,1813.2,0.062,0.152,0.015,32135.234,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-26",22,20.62,4797,,0.01,0.001,1945.909,0.0716,0.166,0.0143,34487.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-27",12,10.96,2447.97,,0.005,0.001,1005.098,0.0624,0.094,0.0183,17813.382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-28",24,24,5998,,0.013,0.001,2388.288,0.0565,0.169,0.008,42327.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-29",11,9.65,2249.09,,0.005,0.001,920.996,0.0691,0.087,0.0229,16322.104,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-30",24,24,5785,,0.012,0.001,2314.704,0.0566,0.164,0.008,41022.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"3A",,"2020-12-31",24,24,5861,,0.012,0.001,2347.488,0.0565,0.166,0.008,41604.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-01",19,17.16,3626.04,,0.008,0.001,1463.096,0.0668,0.118,0.0184,26020.726,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-02",21,20.3,4491.9,,0.01,0.001,1818.697,0.062,0.14,0.0141,32346.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-03",21,19.55,4688.44,,0.01,0.001,1875.099,0.0667,0.139,0.0181,33347.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-04",17,16.07,3706.07,,0.008,0.001,1487.198,0.0634,0.123,0.0164,26449.059,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-05",19,17.66,4076.52,,0.009,0.001,1643.792,0.0628,0.133,0.0168,29235.924,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-06",20,18.45,4505.51,,0.01,0.001,1791.292,0.0682,0.14,0.0183,31858.859,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-07",20,18.5,4101.9,,0.009,0.001,1652.993,0.0658,0.128,0.0173,29397.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-08",18,15.91,3214.38,,0.007,0.001,1318.096,0.0658,0.118,0.0191,23441.551,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-09",19,19,4471,,0.01,0.001,1789.895,0.0573,0.154,0.0107,31833,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-10",19,17.53,4186.76,,0.009,0.001,1676.096,0.0654,0.13,0.0169,29809.118,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-11",18,16.45,3133.43,,0.007,0.001,1297.395,0.0666,0.109,0.0198,23074.509,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-12",18,16.45,3436.33,,0.007,0.001,1400.898,0.0678,0.118,0.0203,24915.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-13",19,16.39,3604.63,,0.008,0.001,1467.691,0.0699,0.135,0.0244,26103.615,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-14",19,17.5,3923.8,,0.008,0.001,1575.298,0.0653,0.127,0.0175,28016.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-15",24,24,5699,,0.012,0.001,2278.296,0.0566,0.145,0.0072,40519,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-16",21,19.76,4483.04,,0.01,0.001,1804.997,0.061,0.13,0.0138,32101.148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-17",20,18.63,4294.52,,0.009,0.001,1728.1,0.0634,0.131,0.016,30733.737,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-18",21,19.61,4663.47,,0.01,0.001,1858.204,0.0627,0.136,0.0147,33047.651,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-19",20,18.3,4354.14,,0.009,0.001,1731.198,0.1756,0.132,0.0102,30790.051,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-20",24,24,5813,,0.012,0.001,2304.696,0.0564,0.145,0.0071,40988.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-21",22,20.55,4502.55,,0.01,0.001,1812.593,0.0655,0.136,0.0169,32236.873,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-22",24,24,5647,,0.012,0.001,2246.904,0.0563,0.142,0.0071,39960.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-23",24,24,5658,,0.012,0.001,2245.392,0.0563,0.141,0.007,39934.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-24",19,17.58,3669.34,,0.008,0.001,1498.8,0.0643,0.119,0.0175,26656.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-25",11,9.57,2204.57,,0.005,0.001,885.703,0.0712,0.086,0.0249,15751.753,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-26",10,8.55,1726.99,,0.004,0.001,708.102,0.0701,0.073,0.0264,12593.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-27",18,14.51,2807.44,,0.006,0.001,1163.6,0.2544,0.124,0.0218,20694.429,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-28",22,20.48,4563.78,,0.01,0.001,1851.29,0.0656,0.138,0.0165,32924.498,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-29",22,20.59,4639.93,,0.01,0.001,1872.701,0.0638,0.139,0.0159,33306.072,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-30",18,15.98,3667.68,,0.008,0.001,1471.198,0.0679,0.123,0.0185,26164.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-01-31",20,19.8,4330,,0.009,0.001,1746.003,0.0581,0.131,0.0095,31052.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-01",19,17.75,4291,,0.009,0.001,1709.697,0.0634,0.132,0.0153,30356.865,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-02",24,24,5514,,0.012,0.001,2204.904,0.0565,0.139,0.0071,39149.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-03",17,14.06,3250.17,,0.007,0.001,1314.905,0.0781,0.137,0.0324,23346.432,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-04",19,17.53,4289.37,,0.009,0.001,1708.596,0.1031,0.141,0.0101,30337.879,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-05",19,17.46,4204.48,,0.009,0.001,1679.704,0.0694,0.13,0.0189,29825.458,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-06",17,15.48,3558.08,,0.008,0.001,1421.792,0.0692,0.115,0.0196,25245.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-07",18,14.92,3327.91,,0.007,0.001,1340.8,0.0802,0.134,0.0306,23807.157,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-08",17,15.75,3630.45,,0.008,0.001,1447.299,0.0643,0.114,0.0164,25698.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-09",24,24,5724,,0.012,0.001,2266.896,0.0564,0.143,0.0071,40250.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-10",24,24,5693,,0.012,0.001,2259.408,0.0566,0.141,0.007,40118.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-11",19,17.57,4104.4,,0.009,0.001,1634.696,0.0648,0.127,0.0167,29025.623,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-12",19,17.72,4074.36,,0.009,0.001,1629.992,0.0637,0.127,0.0158,28942.594,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-13",19,17.78,4297.96,,0.009,0.001,1711.094,0.0637,0.133,0.0156,30381.448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-14",19,17.71,4234.73,,0.009,0.001,1690.703,0.0622,0.126,0.0149,30019.601,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-15",21,19.86,4555.58,,0.01,0.001,1828.907,0.0612,0.133,0.0134,32472.956,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-16",10,8.47,1940.43,,0.004,0.001,788.099,0.0779,0.078,0.0277,13994.172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-17",19,17.53,3764.48,,0.008,0.001,1521.99,0.0652,0.122,0.0163,27024.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-18",19,17.47,4171.99,,0.009,0.001,1666.201,0.0699,0.128,0.0193,29584.858,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-19",19,17.7,4265.6,,0.009,0.001,1698.899,0.0638,0.129,0.0152,30165.542,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-20",19,17.73,4112.74,,0.009,0.001,1648.606,0.0641,0.131,0.0157,29272.576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-21",18,16.55,4043.55,,0.009,0.001,1605.697,0.0659,0.127,0.0177,28511.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-22",9,7.82,1697.43,,0.004,0.001,690.803,0.0679,0.082,0.0277,12265.308,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-23",9,7.54,1621.66,,0.004,0.001,660.602,0.0777,0.073,0.0343,11730.131,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-24",19,17.89,3984.07,,0.009,0.001,1620.494,0.0616,0.127,0.0149,28773.554,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-25",19,17.88,4173.64,,0.009,0.001,1668.794,0.0631,0.128,0.015,29631.124,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-26",20,19.11,4328.02,,0.009,0.001,1746.1,0.0609,0.129,0.0138,31004.241,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-27",20,18.61,4349.73,,0.009,0.001,1749.693,0.0646,0.128,0.0156,31067.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-28",24,24,4807,,0.01,0.001,1968.408,0.0575,0.124,0.0071,34950.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-02-29",10,8.52,1801.06,,0.004,0.001,733.401,0.0731,0.079,0.0282,13022.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-01",19,17.47,4061.8,,0.009,0.001,1630.597,0.0699,0.133,0.0191,28715.214,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-02",17,15.48,3429.6,,0.007,0.001,1386.094,0.0696,0.121,0.021,24409.902,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-03",24,24,5407,,0.012,0.001,2179.488,0.0579,0.138,0.0072,38380.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-04",18,16.88,3883.26,,0.008,0.001,1564.692,0.0633,0.12,0.0159,27554.162,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-05",18,16.48,3424.58,,0.007,0.001,1402.992,0.0688,0.114,0.0196,24707.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-06",18,16.44,3901.35,,0.008,0.001,1569.593,0.0722,0.128,0.0202,27641.745,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-07",17,15.21,3723.84,,0.008,0.0009,1498.094,0.1429,0.125,0.0135,26381.029,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-08",17,15.31,3687.99,,0.008,0.001,1486.999,0.0657,0.115,0.0156,26186.987,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-09",20,18.23,4266.83,,0.009,0.001,1717.995,0.3282,0.14,0.0119,30254.425,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-10",24,24,5391,,0.012,0.001,2180.304,0.0589,0.135,0.007,38395.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-11",21,20.1,4875.68,,0.01,0.001,1961.097,0.0609,0.135,0.0123,34536.472,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-12",21,19.3,4744.9,,0.01,0.001,1893.889,0.1404,0.156,0.0111,33351.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-13",24,23.5,5572,,0.012,0.001,2231.49,0.0582,0.144,0.0078,39297.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-14",13,10.13,2229.1,,0.005,0.001,925.902,0.3028,0.112,0.0444,16304.951,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-15",24,24,5563,,0.012,0.001,2239.296,0.0578,0.146,0.0075,39435.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-16",22,21.25,4694,,0.01,0.001,1897.795,0.0605,0.123,0.009,33420.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-17",17,15.05,3455.53,,0.007,0.001,1397.196,0.0695,0.138,0.0239,24604.616,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-18",18,16.21,3711.99,,0.008,0.001,1497.496,0.1391,0.14,0.0149,26370.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-19",17,15.78,3738.32,,0.008,0.001,1496.401,0.0639,0.124,0.0171,26352.416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-20",19,17.48,3971.58,,0.008,0.001,1598.196,0.0681,0.129,0.0192,28145.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-21",16,15.02,3668.76,,0.008,0.001,1468.4,0.0625,0.124,0.0144,25858.122,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-22",17,15.51,3787.91,,0.008,0.001,1512.892,0.0689,0.125,0.0188,26641.989,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-23",17,15.48,3593.98,,0.008,0.001,1443.494,0.0683,0.112,0.0179,25421.256,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-24",19,16.85,3634.36,,0.008,0.001,1485.496,0.0676,0.117,0.0193,26159.631,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-25",17,15.05,3270.07,,0.007,0.001,1338.802,0.0684,0.125,0.0254,23575.856,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-26",18,16.61,3661.6,,0.008,0.001,1491.794,0.0659,0.114,0.018,26271.181,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-27",17,15.71,3498.22,,0.007,0.001,1415,0.0642,0.12,0.0178,24918.488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-28",17,14.64,3383.3,,0.007,0.001,1362.704,0.0778,0.119,0.0254,23997.342,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-29",11,10.25,2121.5,,0.005,0.001,867.898,0.0665,0.091,0.0218,15284.925,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-30",18,16.45,3662.6,,0.008,0.001,1485.797,0.0698,0.123,0.0205,26164.965,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-03-31",18,16.19,3019.7,,0.007,0.001,1268.6,0.0632,0.13,0.0204,22340.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-01",19,18.77,3792.18,,0.008,0.001,1558.792,0.0585,0.12,0.0098,27507.483,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-02",14,12.19,2636.18,,0.006,0.001,1068.295,0.0689,0.099,0.0224,18850.466,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-03",8,7.3,1741.9,,0.004,0.001,699.997,0.0705,0.077,0.0279,12351.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-04",17,15.7,3743.14,,0.008,0.001,1502.6,0.067,0.118,0.0172,26514.889,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-05",17,16.03,3981.32,,0.008,0.001,1591.795,0.0634,0.131,0.0164,28089.147,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-06",19,18.04,4277.93,,0.009,0.001,1720.096,0.0609,0.132,0.0121,30352.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-07",22,21.23,4821.63,,0.01,0.001,1929.191,0.0606,0.123,0.0092,34043.402,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-08",20,19.28,4779.76,,0.01,0.001,1891.098,0.0623,0.12,0.009,33370.756,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-09",24,23.1,5678,,0.012,0.001,2248.392,0.06,0.158,0.0115,39674.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-10",21,19.24,4435.56,,0.009,0.001,1772.196,0.064,0.134,0.0153,31272.305,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-12",8,7.7,1802.2,,0.004,0.001,729.999,0.0678,0.081,0.0274,12882.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-13",16,13.63,2971.83,,0.006,0.001,1204.797,0.0783,0.101,0.0265,21260.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-14",8,7.33,1686.18,,0.004,0.001,678.501,0.0695,0.068,0.0264,11973.291,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-15",15,13.95,2935.87,,0.006,0.001,1194.999,0.0639,0.103,0.0177,21086.523,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-16",11,9.53,2145.25,,0.005,0.001,866.601,0.0731,0.088,0.0248,15291.416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-17",8,5.74,1266.63,,0.003,0.001,516.198,0.0918,0.069,0.0441,9108.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-20",8,7.22,1273.76,,0.003,0.001,536.598,0.1096,0.082,0.0249,9469.694,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-21",1,0.17,9.18,,0,0.001,4.9,0.057,0.004,0.093,86.394,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-22",10,9.15,1945.3,,0.004,0.001,807.396,0.0816,0.099,0.0241,14247.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-23",9,7.7,1681.7,,0.004,0.001,683.499,0.0714,0.071,0.0257,12060.886,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-24",15,13.58,2887.68,,0.006,0.001,1188.997,0.0681,0.095,0.0201,20981.734,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-25",14,12.95,3120.37,,0.007,0.001,1248.795,0.0649,0.115,0.0189,22035.89,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-26",9,6.72,1401.3,,0.003,0.001,573.203,0.0889,0.071,0.0421,10114.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-27",8,6.51,1354.72,,0.003,0.001,555.498,0.0804,0.064,0.0358,9803.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-28",16,14.61,2821.27,,0.006,0.001,1172.395,0.0694,0.143,0.0268,20688.275,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-29",14,10.94,1831.41,,0.004,0.001,777.603,0.0759,0.102,0.0384,13720.991,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-01",22,21.53,4009.07,,0.009,0.001,1687.995,0.0608,0.143,0.0158,29766.896,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-02",12,9.75,1340.35,,0.003,0.001,609.6,0.0685,0.059,0.0278,10749.562,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-03",4,1.98,192.83,,0.001,0.001,105.9,0.2745,0.033,0.0623,1866.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-04",23,22.98,5082.78,,0.011,0.001,2053.792,0.0577,0.137,0.0077,36217.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-05",21,19.44,4268.87,,0.009,0.001,1734.106,0.0732,0.137,0.0161,30579.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-06",7,5.6,1233.89,,0.003,0.001,496.697,0.0866,0.06,0.0416,8758.971,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-07",8,6.7,1561.3,,0.003,0.001,628.902,0.0739,0.059,0.0266,11090.365,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-08",16,15.22,3301.98,,0.007,0.001,1336.605,0.0639,0.108,0.0165,23569.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-16",12,11.77,2084,,0.005,0.001,927.994,0.0758,0.252,0.0633,16364.03,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-17",24,24,4446,,0.01,0.001,1867.992,0.0586,0.119,0.0073,32941.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-18",22,20.61,3213.58,,0.007,0.001,1404.695,0.0605,0.11,0.0151,24771.441,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-19",24,24,3699,,0.009,0.001,1619.592,0.0571,0.105,0.0074,28560.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-20",1,0.17,8.33,,0,0.001,4.4,0.057,0.004,0.096,77.656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-21",9,7.71,1536.78,,0.003,0.001,649.498,0.0779,0.072,0.0327,11453.171,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-22",9,8.15,1675.05,,0.004,0.001,699.596,0.0652,0.069,0.0244,12337.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-23",9,7.62,1512.11,,0.003,0.001,636.301,0.0761,0.066,0.0324,11221.143,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-24",9,7.62,1494.61,,0.003,0.001,630.198,0.0744,0.066,0.0317,11112.397,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-25",16,14.12,2818.04,,0.006,0.0009,1163.204,0.1228,0.112,0.0206,20512.999,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-26",18,16.45,3726.54,,0.008,0.001,1497.904,0.0701,0.119,0.0189,26414.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-27",14,12.78,3018.76,,0.006,0.001,1211.403,0.0663,0.104,0.0184,21362.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-28",23,22.17,4512.5,,0.01,0.001,1857.292,0.063,0.119,0.0106,32751.753,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-29",15,13.42,2780.54,,0.006,0.001,1127.495,0.0698,0.097,0.0199,19883.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-30",17,15.51,2737.65,,0.006,0.001,1167.406,0.0654,0.103,0.0191,20586.463,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-05-31",10,8.59,1523.7,,0.003,0.001,653.003,0.0698,0.073,0.0285,11514.994,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-01",11,9.5,2186.58,,0.005,0.001,876.698,0.0733,0.084,0.0247,15449.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-02",20,19.38,4434.64,,0.009,0.001,1779.103,0.061,0.124,0.0125,31352.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-03",19,16.71,3998.36,,0.008,0.001,1581.101,0.0711,0.119,0.0185,27863.346,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-04",19,17.98,4053.28,,0.009,0.001,1622.893,0.0631,0.122,0.0149,28599.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-05",7,5.44,881.04,,0.002,0.001,373.402,0.0779,0.048,0.0419,6581.122,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-06",10,8.48,1198.32,,0.003,0.001,523.699,0.0679,0.064,0.0319,9229.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-07",7,5.54,755.78,,0.002,0.001,336.799,0.0711,0.053,0.0446,5935.099,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-08",8,6.61,1470.4,,0.003,0.001,599.798,0.0804,0.078,0.0386,10570.299,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-09",8,7.78,1862.74,,0.004,0.001,748,0.0585,0.083,0.0174,13180.838,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-10",13,10.78,2560.78,,0.005,0.001,1032.498,0.0759,0.098,0.0251,18195.493,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-11",9,8.08,1914.3,,0.004,0.001,768.797,0.0688,0.08,0.025,13547.758,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-12",7,6.28,1303.39,,0.003,0.001,535.501,0.0643,0.063,0.0271,9437.378,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-13",8,6.45,900.43,,0.002,0.001,400.7,0.0719,0.052,0.0371,7061.353,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-14",9,7.3,1518.96,,0.003,0.001,625.902,0.0938,0.085,0.0298,11030.608,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-15",8,6.71,1472.71,,0.003,0.001,602.202,0.0758,0.063,0.0304,10613.349,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-16",7,5.52,1248.08,,0.003,0.001,508.801,0.0851,0.062,0.0384,8965.756,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-17",14,10.65,1864.82,,0.004,0.001,790.304,0.0956,0.126,0.0376,13927.636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-18",12,10.82,2190.67,,0.005,0.001,895.398,0.0646,0.093,0.0225,15779.699,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-19",14,13.28,3249.2,,0.007,0.001,1293.299,0.0648,0.109,0.018,22791.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-20",8,6.56,1497.38,,0.003,0.001,602.497,0.0825,0.068,0.0359,10618.144,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-21",8,7.53,1643.62,,0.004,0.001,662.7,0.0651,0.072,0.0286,11678.108,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-22",24,23.7,5426.9,,0.012,0.001,2188.102,0.0578,0.143,0.0076,38560.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-23",10,8.73,2086.92,,0.004,0.001,832.397,0.0697,0.088,0.0253,14669.326,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-24",11,10,2402.44,,0.005,0.001,958.2,0.0674,0.095,0.0225,16885.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-25",10,8.56,2036.56,,0.004,0.001,814.698,0.072,0.084,0.026,14356.708,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-29",8,7.7,1532.9,,0.003,0.001,630.699,0.0663,0.081,0.0286,11114.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-06-30",6,3.68,659.82,,0.001,0.001,277.502,0.1158,0.059,0.0667,4891.017,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-01",5,4.95,994.9,,0.002,0.001,412.8,0.0596,0.085,0.0306,7242.595,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-02",3,2.43,361.44,,0.001,0.001,158.4,0.0617,0.014,0.015,2780.273,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-03",9,7.1,1622.9,,0.003,0.001,659.902,0.1131,0.08,0.0339,11579.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-04",8,6.52,1522.41,,0.003,0.001,620.502,0.0879,0.067,0.0361,10888.614,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-05",10,9.37,2217.95,,0.005,0.001,894.798,0.0683,0.078,0.0225,15701.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-06",24,24,5086,,0.011,0.001,2082.288,0.0584,0.129,0.0071,36538.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-07",11,8.75,1958.34,,0.004,0.001,796.302,0.0811,0.086,0.0321,13972.066,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-08",10,9.3,2087.5,,0.004,0.001,850.299,0.067,0.076,0.0225,14920.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-09",24,24,5005,,0.011,0.001,2068.008,0.0585,0.13,0.0072,36287.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-10",24,24,4857,,0.011,0.001,2013.888,0.0593,0.126,0.0072,35337.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-11",24,24,5328,,0.011,0.001,2171.688,0.0585,0.135,0.0071,38106.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-12",24,24,5425,,0.012,0.001,2205.6,0.0581,0.14,0.0073,38701.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-13",24,24,4988,,0.011,0.001,2055.888,0.0582,0.131,0.0073,36075.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-14",24,24,4810,,0.01,0.001,1994.088,0.0587,0.125,0.0072,34991.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-15",24,24,4328,,0.01,0.001,1833,0.0584,0.118,0.0073,32163,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-16",24,24,4068,,0.009,0.001,1748.688,0.0583,0.109,0.0071,30684.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-17",24,24,4745,,0.01,0.001,1979.304,0.0588,0.126,0.0073,34730.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-18",13,11.57,2727.22,,0.006,0.001,1102.1,0.0708,0.098,0.0226,19338.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-19",10,8.57,1854.45,,0.004,0.001,758.6,0.0743,0.076,0.0283,13311.371,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-20",24,23.18,4388.62,,0.01,0.001,1849.092,0.0618,0.12,0.0099,32445.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-21",12,11.1,2553.3,,0.005,0.001,1031.001,0.0818,0.109,0.0178,18090.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-22",24,24,4784,,0.01,0.001,1988.4,0.0587,0.126,0.0072,34890.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-23",24,24,4491,,0.01,0.001,1895.808,0.0586,0.118,0.0071,33266,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-24",24,24,4822,,0.011,0.001,1998.192,0.0586,0.126,0.0072,35062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-25",11,9.53,2279.59,,0.005,0.001,919.702,0.076,0.083,0.0259,16137.935,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-26",12,10.28,2426.64,,0.005,0.001,984.896,0.1079,0.098,0.0179,17281.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-27",15,13.51,3255.45,,0.007,0.001,1310.902,0.0707,0.103,0.0207,23001.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-28",24,24,5817,,0.012,0.001,2326.992,0.0573,0.145,0.0071,40831,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-29",24,24,5670,,0.012,0.001,2286,0.0578,0.143,0.0071,40112.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-30",24,24,5915,,0.012,0.001,2367.696,0.0573,0.148,0.0071,41545,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-07-31",24,24,5426,,0.012,0.001,2196.288,0.0575,0.138,0.0072,38537.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-01",24,24,4710,,0.01,0.001,1945.608,0.0584,0.121,0.0071,34269.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-02",17,15.29,3467.83,,0.007,0.001,1400.197,0.0775,0.117,0.0168,24661.757,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-03",24,24,4891,,0.011,0.001,2003.088,0.0578,0.126,0.0072,35280.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-04",24,24,5265,,0.011,0.001,2162.088,0.0582,0.14,0.0074,38082.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-05",24,23.43,4587.61,,0.01,0.001,1914.489,0.0587,0.142,0.0091,33720.384,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-06",8,7.42,1473.42,,0.003,0.001,617.7,0.0655,0.068,0.0288,10879.076,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-07",24,24,4786,,0.011,0.001,2010.696,0.0587,0.145,0.0082,35414.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-08",22,21.7,4465,,0.01,0.001,1865.397,0.0584,0.14,0.0087,32856.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-09",9,5.96,1000.96,,0.002,0.001,426.998,0.2273,0.176,0.062,7521.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-10",24,24,5491,,0.012,0.001,2232.504,0.0579,0.157,0.008,39322.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-11",24,24,5482,,0.012,0.001,2227.2,0.0578,0.158,0.008,39229.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-12",24,24,5616,,0.012,0.001,2268.192,0.0579,0.162,0.0081,39950.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-13",24,24,6072,,0.013,0.001,2413.392,0.0567,0.171,0.008,42508.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-14",24,23.15,5481.6,,0.012,0.001,2182.304,0.0648,0.157,0.0119,38437.165,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-15",16,15.33,3726.85,,0.008,0.001,1484.005,0.0633,0.134,0.0183,26139.268,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-16",24,24,5565,,0.012,0.001,2222.4,0.0575,0.157,0.008,39144.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-17",17,15.48,3781.63,,0.008,0.001,1504.099,0.0739,0.135,0.0232,26493.002,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-18",24,24,6056,,0.013,0.001,2396.208,0.0567,0.17,0.008,42205.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-19",24,24,5422,,0.012,0.001,2176.296,0.0585,0.157,0.0082,38331.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-20",17,15.45,2848.54,,0.006,0.001,1179.592,0.0721,0.11,0.0258,20777.719,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-21",24,24,5946,,0.012,0.001,2356.488,0.0568,0.17,0.0082,41506.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-22",24,24,6104,,0.013,0.001,2405.592,0.0568,0.17,0.008,42371.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-23",16,14.52,3451.2,,0.007,0.001,1373.403,0.0693,0.127,0.0221,24189.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-24",24,24,5945,,0.012,0.001,2355.408,0.0571,0.169,0.0081,41486.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-25",24,24,5856,,0.012,0.001,2322.288,0.0573,0.167,0.0082,40904,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-26",16,14.35,3069.25,,0.007,0.001,1243.8,0.0747,0.114,0.0234,21907.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-27",24,24,4293,,0.009,0.001,1790.208,0.0586,0.129,0.0081,31532.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-28",24,24,5318,,0.011,0.001,2155.992,0.0583,0.155,0.0082,37974.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-29",24,23.15,4824.05,,0.01,0.001,1976.593,0.0635,0.144,0.0119,34815.165,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-30",11,10.33,2078.19,,0.005,0.001,862.204,0.065,0.084,0.0234,15186.346,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-08-31",24,24,5223,,0.011,0.001,2134.704,0.0576,0.153,0.0081,37598.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-01",24,24,5317,,0.011,0.001,2179.8,0.058,0.155,0.0081,38100.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-02",24,24,5200,,0.011,0.001,2140.608,0.058,0.153,0.0082,37415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-03",24,24,5596,,0.012,0.001,2278.488,0.0578,0.162,0.0081,39826.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-04",17,15.55,3687.66,,0.008,0.001,1494.293,0.0677,0.133,0.0209,26117.893,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-05",24,24,4683,,0.01,0.001,1946.496,0.0591,0.137,0.008,34023,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-06",24,24,4865,,0.01,0.001,1999.296,0.0593,0.142,0.0081,34946.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-07",24,24,5607,,0.012,0.001,2255.904,0.0583,0.159,0.0081,39430.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-08",24,24,4969,,0.011,0.001,2043.888,0.0589,0.146,0.0082,35725.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-09",24,24,4736,,0.01,0.001,1975.008,0.0586,0.141,0.0082,34521.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-10",12,10.45,1858.1,,0.004,0.001,788.097,0.0773,0.082,0.033,13775.399,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-11",11,10.08,2225.2,,0.005,0.001,910.899,0.0652,0.1,0.025,15921.812,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-12",13,11.79,2748.6,,0.006,0.001,1116.195,0.0661,0.111,0.0227,19509.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-13",10,8.84,2054.04,,0.004,0.001,835.796,0.0666,0.09,0.0273,14608.722,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-14",13,10.92,2551.56,,0.005,0.001,1036.602,0.0727,0.118,0.0273,18118.132,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-15",11,10.35,2437.7,,0.005,0.001,984.802,0.0658,0.101,0.024,17212.97,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-16",14,12.82,3013.36,,0.006,0.001,1226.399,0.0633,0.11,0.0189,21436.086,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-17",14,12.75,3071.55,,0.006,0.001,1238.203,0.0666,0.123,0.0213,21641.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-18",17,15.54,3454.22,,0.007,0.001,1415.492,0.0666,0.126,0.0202,24741.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-19",12,11.32,2616.83,,0.006,0.001,1064.702,0.0652,0.115,0.0233,18610.636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-20",21,19.82,4292.5,,0.009,0.001,1790.697,0.063,0.152,0.0167,31299.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-21",20,18.83,4423.7,,0.009,0.001,1797.191,0.0625,0.152,0.0167,31413.329,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-22",12,10.8,2368.04,,0.005,0.001,968.5,0.0648,0.102,0.0241,16929.144,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-23",14,12.6,2799.44,,0.006,0.001,1144.899,0.0634,0.089,0.0139,20010.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-24",2,0.57,15.11,,0,0.001,19.9,0.0615,0.023,0.128,347.609,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-25",3,1.91,114.22,,0,0.001,87.6,0.0747,0.086,0.1117,1531.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-27",8,6.82,1356.44,,0.003,0.001,564.901,0.087,0.075,0.0444,9873.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-28",20,18.7,3860.98,,0.008,0.001,1589.594,0.0637,0.138,0.0174,27785.022,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-29",14,12.79,2809.78,,0.006,0.001,1154.604,0.0661,0.122,0.0239,20180.733,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-09-30",24,24,5694,,0.012,0.001,2274.288,0.0576,0.161,0.0081,39752.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-01",24,24,5590,,0.012,0.001,2236.296,0.0573,0.162,0.0083,39240.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-02",15,13.52,3207.62,,0.007,0.001,1291.904,0.1043,0.145,0.0143,22669.276,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-03",19,16.98,3940.56,,0.008,0.001,1599.397,0.0692,0.143,0.0219,28064.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-04",9,7.8,1821.34,,0.004,0.001,743.901,0.0694,0.094,0.0306,13053.323,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-05",20,19.33,4687.19,,0.01,0.001,1907.195,0.0621,0.143,0.013,33466.192,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-06",24,24,5837,,0.012,0.001,2348.808,0.0572,0.166,0.008,41213.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-07",24,24,5901,,0.012,0.001,2347.008,0.0571,0.166,0.008,41182.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-08",24,24,5606,,0.012,0.001,2267.4,0.0571,0.161,0.0081,39786.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-09",10,7.77,1612.08,,0.004,0.001,665.299,0.0929,0.095,0.0273,11673.751,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-12",10,9.73,2037.23,,0.004,0.001,840.196,0.0631,0.094,0.0226,14742.605,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-13",24,24,5387,,0.011,0.001,2183.808,0.0576,0.158,0.0083,38319.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-14",24,24,5918,,0.012,0.001,2342.304,0.0571,0.165,0.008,41100.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-15",24,23.18,5603.96,,0.012,0.001,2224.098,0.0613,0.161,0.0108,39026.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-16",14,13.3,3094.9,,0.007,0.001,1247.899,0.0644,0.117,0.0206,21896.03,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-17",24,24,5550,,0.012,0.001,2220.792,0.0574,0.161,0.0083,38967.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-18",24,24,5648,,0.012,0.001,2281.008,0.0572,0.16,0.008,40024.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-19",24,24,5823,,0.012,0.001,2357.4,0.0571,0.167,0.0081,41364.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-20",24,24,5734,,0.012,0.001,2317.008,0.0572,0.163,0.008,40656.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-21",13,11.65,2739.3,,0.006,0.001,1111.596,0.0672,0.106,0.0238,19505.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-22",24,24,5697,,0.012,0.001,2277.504,0.0572,0.161,0.008,39963,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-23",24,24,5652,,0.012,0.001,2260.608,0.057,0.161,0.0081,39666.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-24",24,24,5841,,0.012,0.001,2366.592,0.0571,0.167,0.008,41527.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-25",11,9.27,2164.76,,0.005,0.001,884.701,0.1167,0.102,0.0213,15523.996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-26",24,24,5747,,0.012,0.001,2317.008,0.0573,0.169,0.0083,40655.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-27",24,24,5614,,0.012,0.001,2271.192,0.0574,0.164,0.0083,39853.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-28",17,15.54,3624.7,,0.008,0.001,1448.499,0.0675,0.139,0.023,25417.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-29",24,24,5956,,0.012,0.001,2367,0.057,0.167,0.008,41533.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-30",21,19.14,4585.94,,0.01,0.001,1847.105,0.062,0.161,0.0139,32410.926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-05",11,10.23,1917.15,,0.004,0.001,842.604,0.0755,0.206,0.0478,14951.022,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-06",24,24,5262,,0.011,0.001,2122.104,0.0571,0.152,0.0081,37655.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-07",24,24,5347,,0.011,0.001,2155.8,0.0571,0.155,0.0081,38253.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-08",24,24,5533,,0.012,0.001,2230.608,0.0568,0.164,0.0083,39581.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-09",21,19.23,4480.05,,0.01,0.001,1804.793,0.1058,0.185,0.0149,32026.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-10",20,19.22,4682.32,,0.01,0.001,1872.393,0.0588,0.174,0.0127,33224.43,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-11",24,24,5828,,0.012,0.001,2325.888,0.0567,0.167,0.0081,41272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-12",20,18.97,4392.18,,0.009,0.001,1759.6,0.0931,0.161,0.0107,31223.662,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-13",19,17.45,3990.25,,0.009,0.001,1596.902,0.0633,0.157,0.019,28336.525,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-14",10,9.32,2169.8,,0.005,0.001,877.301,0.0669,0.093,0.0256,15567.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-15",17,15.47,3595.34,,0.008,0.001,1446.599,0.0713,0.14,0.0245,25669.806,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-16",19,17.47,4041.66,,0.009,0.001,1621.898,0.0689,0.144,0.0211,28780.773,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-17",20,18.7,4483.7,,0.01,0.001,1787.701,0.1329,0.172,0.0111,31722.022,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-18",22,20.57,4662.95,,0.01,0.001,1873.187,0.0702,0.159,0.0133,33239.154,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-19",20,18.52,3950.98,,0.009,0.001,1603.499,0.0645,0.145,0.0188,28453.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-20",24,24,5807,,0.012,0.001,2302.8,0.0565,0.163,0.008,40862.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-21",18,17.04,3967.28,,0.008,0.001,1581.193,0.0628,0.14,0.0184,28058.308,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-22",12,10.31,2406.54,,0.005,0.001,963.098,0.0882,0.105,0.0248,17089.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-23",19,18.02,4205.8,,0.009,0.001,1686.492,0.0623,0.152,0.0174,29926.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-24",21,19.25,4510.55,,0.01,0.001,1811.291,0.1216,0.167,0.013,32141.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-25",19,18,4253.9,,0.009,0.001,1707.894,0.063,0.165,0.0187,30305.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-26",24,24,5008,,0.011,0.001,2061.504,0.0582,0.147,0.008,36580.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-27",18,16.52,3669.06,,0.008,0.001,1490.599,0.0656,0.139,0.0207,26450.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-28",10,8.19,1914.78,,0.004,0.001,776.502,0.0684,0.102,0.0288,13779.446,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-29",3,1.8,152.12,,0,0.001,86.6,0.1023,0.079,0.1533,1536.338,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-11-30",20,18.71,4490.49,,0.01,0.001,1809.706,0.1311,0.187,0.0121,32112.481,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-01",21,19.27,4678.29,,0.01,0.001,1874.701,0.1238,0.177,0.013,33225.093,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-02",20,19.27,4631.63,,0.01,0.001,1849.497,0.0583,0.166,0.0121,32778.462,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-03",24,24,6001,,0.013,0.001,2389.8,0.0565,0.174,0.0083,42353.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-04",24,24,5940,,0.013,0.001,2361.696,0.0567,0.17,0.0081,41856.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-05",20,19.08,4724.04,,0.01,0.001,1886.401,0.0697,0.168,0.0141,33432.505,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-06",20,18.77,4579.1,,0.01,0.001,1830.995,0.0729,0.181,0.0142,32450.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-07",24,24,5991,,0.013,0.001,2374.2,0.0564,0.171,0.0081,42078.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-08",17,15.51,3606.19,,0.008,0.001,1437.9,0.068,0.137,0.0234,25482.798,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-09",24,24,5420,,0.012,0.001,2173.8,0.057,0.158,0.0083,38526.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-10",24,24,5244,,0.011,0.001,2121.696,0.0577,0.153,0.0081,37603,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-11",24,24,5630,,0.012,0.001,2255.4,0.0572,0.161,0.008,39972.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-12",17,15.55,3756.35,,0.008,0.001,1499.502,0.0659,0.133,0.0196,26575.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-13",24,24,5881,,0.012,0.001,2341.104,0.0567,0.167,0.008,41490.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-14",24,24,5807,,0.012,0.001,2316.792,0.057,0.167,0.0081,41059.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-15",24,24,5952,,0.013,0.001,2369.208,0.0568,0.171,0.0081,41989.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-16",24,24,5635,,0.012,0.001,2251.608,0.0571,0.162,0.0081,39905,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-17",20,18.57,4429.96,,0.009,0.001,1773.304,0.065,0.153,0.0194,31427.024,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-18",24,24,5629,,0.012,0.001,2254.896,0.0572,0.165,0.0083,39962.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-19",19,18.03,4416.2,,0.009,0.001,1763.297,0.0638,0.151,0.0167,31250.067,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-20",20,19,4378.22,,0.009,0.001,1759.192,0.3318,0.159,0.0103,31177.632,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-21",20,18.23,4530.12,,0.01,0.001,1809.892,0.1214,0.174,0.0146,32076.379,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-22",20,18.75,4536.37,,0.01,0.001,1819.706,0.0629,0.148,0.0164,32249.827,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-23",24,24,5860,,0.012,0.001,2332.008,0.0567,0.17,0.0083,41328.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-24",24,24,6047,,0.013,0.001,2399.304,0.0565,0.175,0.0082,42523.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-25",20,18.8,4510.5,,0.01,0.001,1805.59,0.107,0.168,0.0108,31999.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-26",21,19.8,4620.96,,0.01,0.001,1857.299,0.0809,0.178,0.0129,32916.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-27",12,10.1,2186.52,,0.005,0.001,884.699,0.1143,0.096,0.0304,15679.251,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-28",24,24,6043,,0.013,0.001,2394.288,0.0565,0.171,0.008,42433.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-29",11,9.5,2301.1,,0.005,0.001,922.203,0.0734,0.1,0.0295,16343.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-30",24,24,5786,,0.012,0.001,2308.704,0.0568,0.164,0.008,40916.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Moss Landing Power Plant",260,"4A",,"2020-12-31",24,24,5867,,0.012,0.001,2339.088,0.0566,0.168,0.0081,41455.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-03",6,5.3,456.8,,0.001,0.001,247.74,0.059,0.015,0.0078,4167.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-06",7,4.83,253.99,,0.001,0.001,156.926,0.0594,0.011,0.0189,2639.613,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-07",8,5.12,366.46,,0.001,0.001,208.03,0.0591,0.012,0.0229,3500.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-08",15,12.37,785.12,,0.002,0.001,459.605,0.0591,0.024,0.0114,7732.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-09",9,6.6,388.48,,0.001,0.001,231.004,0.0591,0.013,0.0156,3888.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-10",3,1.78,93.08,,0,0.001,57.756,0.0593,0.006,0.0337,970.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-14",5,3.08,112.56,,0,0.001,78.642,0.0592,0.006,0.0094,1322.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-15",3,1.53,39.1,,0,0.001,32.059,0.0593,0.003,0.0147,538.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-16",2,1.28,28.16,,0,0.001,24.739,0.059,0.003,0.02,415.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-17",2,1.3,29.5,,0,0.001,25.193,0.0595,0.003,0.011,424.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-20",4,2.55,235.8,,0.001,0.001,126.52,0.059,0.008,0.026,2129.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-24",2,1.3,28.62,,0,0.001,25.059,0.06,0.003,0.011,421.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-28",3,2.55,130.1,,0,0.001,81.699,0.0593,0.006,0.009,1374.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-29",5,4.55,269.3,,0.001,0.001,160.355,0.0592,0.009,0.0092,2698.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-30",7,5.32,525.2,,0.001,0.001,277.864,0.059,0.016,0.0179,4674.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-01-31",12,9.62,321.24,,0.001,0.001,234.956,0.0594,0.013,0.0128,3952.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-02",12,8.85,295.17,,0.001,0.001,215.595,0.0592,0.014,0.0197,3626.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-03",4,2.6,79.86,,0,0.001,59.107,0.0593,0.005,0.0105,995.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-04",6,2.62,120.64,,0,0.001,77.732,0.0593,0.009,0.0397,1307.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-07",7,5.55,523.45,,0.001,0.001,279.44,0.0591,0.017,0.0184,4700.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-08",3,1.28,71.78,,0,0.001,43.232,0.059,0.004,0.032,727.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-09",9,7.55,276.8,,0.001,0.001,194.94,0.0591,0.011,0.0157,3281.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-14",7,4.97,302.59,,0.001,0.001,178.591,0.059,0.015,0.02,3006.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-18",2,1.3,44.36,,0,0.001,31.839,0.059,0.004,0.0195,536.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-19",5,2.6,66.6,,0,0.001,53.388,0.0592,0.005,0.0256,897.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-20",6,5.05,345.86,,0.001,0.001,197.782,0.0592,0.012,0.009,3327.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-21",8,7.29,611.42,,0.002,0.001,333.34,0.059,0.02,0.007,5609.334,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-24",3,1.3,31.68,,0,0.001,26.314,0.0593,0.003,0.033,442.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-25",6,3.32,181.02,,0.001,0.001,110.469,0.0592,0.011,0.0218,1857.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-26",6,3.85,210.87,,0.001,0.001,127.8,0.0593,0.009,0.029,2149.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-27",11,8.6,673.65,,0.002,0.001,374.72,0.059,0.02,0.0135,6305.634,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-28",3,1.3,41.8,,0,0.001,30.44,0.0593,0.004,0.0347,512.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-01",13,12.55,1074.85,,0.003,0.001,585.403,0.0592,0.032,0.0065,9851.513,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-02",7,5.35,256.87,,0.001,0.001,162.748,0.0593,0.01,0.0117,2738.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-03",12,9.36,855.81,,0.002,0.001,457.763,0.0592,0.025,0.0127,7702.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-05",10,8.61,702.24,,0.002,0.001,383.993,0.059,0.02,0.0075,6460.575,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-08",5,3.61,156.84,,0.001,0.001,104.203,0.0596,0.007,0.0116,1752.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-09",5,3.37,225.49,,0.001,0.001,129.953,0.0592,0.011,0.0096,2186.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-12",11,8.87,616.71,,0.002,0.001,355.417,0.059,0.02,0.0068,5982.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-13",14,11.86,1125.75,,0.003,0.001,607.432,0.059,0.032,0.0109,10223.731,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-14",16,14.55,1430.55,,0.004,0.001,763.445,0.059,0.038,0.0105,12846.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-15",3,1.3,95.22,,0,0.001,54.204,0.0593,0.005,0.0313,911.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-16",9,7.8,786.02,,0.002,0.001,414.834,0.059,0.025,0.0077,6979.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-21",3,2.05,93.05,,0,0.001,60.393,0.059,0.011,0.0177,1016.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-22",3,1.54,64.99,,0,0.001,43.358,0.059,0.004,0.0133,729.615,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-24",2,1.29,46.66,,0,0.001,32.901,0.059,0.004,0.0125,553.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-28",4,3.05,211.37,,0.001,0.001,121.191,0.059,0.008,0.0258,2039.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-05",5,3.55,283.42,,0.001,0.001,153.947,0.0592,0.009,0.0102,2589.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-06",3,1.55,82.16,,0,0.001,49.637,0.059,0.004,0.0313,835.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-13",4,2.47,185.5,,0.001,0.001,102.565,0.0595,0.007,0.0158,1725.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-22",3,1.1,8.93,,0,0.001,13.051,0.0597,0.009,0.0887,218.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-23",1,0.57,0,,0,0.001,4.332,0.059,0.002,0.046,73.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-24",2,0.43,5.98,,0,0.001,6.344,0.059,0.004,0.085,106.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-01",13,11.24,1122.04,,0.003,0.001,587.992,0.0591,0.036,0.0098,9893.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-11",13,10.44,929.19,,0.002,0.001,495.118,0.059,0.031,0.0112,8333.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-13",8,4.57,104.75,,0,0.001,89.454,0.0594,0.007,0.0221,1505.735,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-15",4,2.52,104.83,,0,0.001,69.501,0.0593,0.006,0.011,1168.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-16",5,4.05,227.46,,0.001,0.001,138.208,0.059,0.009,0.0216,2324.603,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-17",2,1.3,39.38,,0,0.001,29.646,0.059,0.003,0.018,498.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-18",3,2.29,197.39,,0.001,0.001,107.111,0.059,0.007,0.0133,1801.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-21",8,5.09,332.22,,0.001,0.001,193.536,0.0593,0.011,0.0173,3256.981,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-22",4,3.05,245.6,,0.001,0.001,135.688,0.059,0.008,0.011,2283.199,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-24",4,2.54,77.64,,0,0.001,59.266,0.0593,0.005,0.0248,996.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-25",3,1.28,31.21,,0,0.001,26.185,0.059,0.003,0.031,441.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-26",6,5.05,226.16,,0.001,0.001,149.051,0.0597,0.008,0.0185,2506.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-27",7,5.77,176.36,,0.001,0.001,134.48,0.0591,0.008,0.0076,2263.161,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-28",11,7.61,697.81,,0.002,0.001,375.906,0.0591,0.02,0.0187,6324.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-29",13,10.35,371.46,,0.001,0.001,263.816,0.0593,0.014,0.0072,4439.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-30",6,3.6,179.16,,0.001,0.001,112.447,0.0592,0.007,0.0182,1893.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-05-31",7,3.83,91.04,,0,0.001,76.911,0.0594,0.006,0.0213,1293.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-01",8,4.36,104.48,,0,0.001,88.006,0.0594,0.007,0.0164,1482.007,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-02",11,10.03,333.76,,0.001,0.001,248.415,0.0592,0.013,0.0064,4180.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-03",7,5.28,180.47,,0.001,0.001,133.556,0.0593,0.008,0.016,2246.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-04",4,2.3,64.08,,0,0.001,51.298,0.0598,0.004,0.025,862.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-08",7,5.58,274.1,,0.001,0.001,176.96,0.0591,0.012,0.0103,2977.242,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-09",7,5.08,326.13,,0.001,0.001,191.575,0.0591,0.013,0.0094,3223.771,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-10",5,2.6,76.34,,0,0.001,58.996,0.0592,0.006,0.0226,992.709,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-11",3,1.28,32.47,,0,0.001,27.182,0.0593,0.003,0.0313,457.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-12",3,1.28,28.21,,0,0.001,25.178,0.059,0.003,0.0303,424.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-13",2,1.28,27.6,,0,0.001,24.768,0.059,0.003,0.01,417.144,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-14",6,4.35,138.6,,0.001,0.001,104.66,0.0592,0.007,0.019,1761.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-15",8,4.85,124.55,,0.001,0.001,103.43,0.0593,0.008,0.0205,1740.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-16",2,1.55,51.6,,0,0.001,37.99,0.0595,0.004,0.012,638.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-17",6,2.6,55.25,,0,0.001,49.995,0.0592,0.005,0.0235,841.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-18",6,4.58,108.58,,0,0.001,93.69,0.0593,0.008,0.0213,1576.087,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-19",6,3.56,141.84,,0,0.001,98.633,0.0593,0.008,0.021,1658.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-20",10,7.08,374.3,,0.001,0.001,236.26,0.0591,0.014,0.0199,3975.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-21",4,2.6,77.2,,0,0.001,59.09,0.0593,0.008,0.0148,994.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-22",4,3.28,115.59,,0,0.001,84.278,0.059,0.006,0.0095,1418.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-23",5,2.62,90.57,,0,0.001,65.886,0.0592,0.005,0.0208,1107.867,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-24",3,2.05,89.5,,0,0.001,59.82,0.0593,0.006,0.0097,1006.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-25",3,1.55,34,,0,0.001,30.345,0.059,0.003,0.0313,511.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-26",8,6.12,363.59,,0.001,0.001,220.181,0.0591,0.013,0.0068,3705.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-27",8,7.3,422.2,,0.001,0.001,258.35,0.0591,0.013,0.007,4346.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-28",3,2.05,111.7,,0,0.001,68.82,0.0593,0.005,0.012,1158.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-29",5,2.6,64.08,,0,0.001,53.644,0.059,0.006,0.0242,902.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-06-30",4,2.58,58.02,,0,0.001,50.642,0.0593,0.004,0.0115,852.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-01",8,4.6,106.4,,0,0.001,92.47,0.0593,0.008,0.0216,1555.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-02",6,3.58,136.1,,0,0.001,94.941,0.059,0.007,0.0178,1598.447,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-03",5,3.62,213.98,,0.001,0.001,128.713,0.0592,0.009,0.008,2165.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-04",6,4.35,284.7,,0.001,0.001,167.66,0.0592,0.01,0.0088,2821.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-05",12,9.6,447.75,,0.001,0.001,292.2,0.059,0.015,0.011,4916.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-06",4,2.62,90.84,,0,0.001,64.955,0.059,0.005,0.0078,1093.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-07",6,3.6,202.1,,0.001,0.001,123.995,0.0593,0.008,0.0182,2086.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-08",2,1.3,40.7,,0,0.001,30.46,0.0595,0.003,0.01,512.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-09",4,2.8,234.4,,0.001,0.001,129.94,0.059,0.009,0.0078,2186.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-10",8,6.55,492.6,,0.001,0.001,281.155,0.0591,0.014,0.0078,4729.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-11",8,7.55,650.65,,0.002,0.001,358.92,0.0591,0.018,0.0066,6038.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-12",8,6.82,630.9,,0.002,0.001,342.196,0.059,0.017,0.0138,5759.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-13",7,4.87,330.12,,0.001,0.001,191.067,0.0593,0.011,0.0084,3215.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-14",2,1.55,67.85,,0,0.001,44.765,0.059,0.004,0.009,753.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-15",2,1.57,99.55,,0,0.001,58.703,0.059,0.005,0.012,987.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-16",2,1.32,60.54,,0,0.001,39.252,0.0595,0.004,0.011,659.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-18",7,3.83,155.7,,0.001,0.001,106.033,0.059,0.007,0.0161,1784.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-21",2,1.55,82.75,,0,0.001,51.005,0.059,0.005,0.0115,857.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-22",3,1.55,42.55,,0,0.001,34.04,0.0593,0.003,0.0313,571.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-23",6,2.58,55.25,,0,0.001,49.113,0.0592,0.005,0.0278,827.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-24",6,4.1,167,,0.001,0.001,114.07,0.0597,0.009,0.0085,1917.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-25",4,2.82,253.85,,0.001,0.001,138.309,0.0593,0.008,0.0075,2327.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-26",5,3.57,116.89,,0,0.001,87.44,0.059,0.006,0.0194,1473.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-27",7,5.3,312.85,,0.001,0.001,189.44,0.0591,0.011,0.0159,3187.905,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-28",7,5.3,205,,0.001,0.001,143.51,0.059,0.008,0.0156,2415.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-29",7,5.28,308.15,,0.001,0.001,188.563,0.0591,0.01,0.0153,3173.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-30",10,8.3,701.85,,0.002,0.001,390.225,0.0591,0.019,0.012,6566.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-07-31",10,9.05,801.7,,0.002,0.001,440.59,0.0591,0.022,0.0065,7413.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-01",7,5.3,238,,0.001,0.001,156.355,0.0594,0.009,0.0163,2629.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-02",7,5.3,166,,0.001,0.001,126.1,0.0597,0.008,0.0159,2120.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-03",8,6.3,191.85,,0.001,0.001,146.69,0.0593,0.009,0.015,2468.715,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-04",5,2.62,66.37,,0,0.001,54.208,0.059,0.005,0.0218,912.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-05",3,1.8,48.85,,0,0.001,38.8,0.0593,0.004,0.01,652.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-06",3,1.8,48.85,,0,0.001,38.7,0.059,0.004,0.0103,651.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-07",4,2.3,64.15,,0,0.001,50.875,0.0595,0.004,0.025,856.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-08",5,4.28,187.09,,0.001,0.001,123.745,0.0592,0.007,0.0082,2081.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-09",6,4.55,216.5,,0.001,0.001,137.8,0.0592,0.008,0.018,2319.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-10",8,5.08,169.16,,0.001,0.001,123.579,0.0593,0.007,0.0095,2079.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-11",6,4.3,139.85,,0.001,0.001,103.02,0.0595,0.007,0.0178,1733.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-12",7,5.78,354.55,,0.001,0.001,211,0.0593,0.012,0.0069,3548.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-13",11,9.78,705.4,,0.002,0.001,400.305,0.059,0.021,0.0063,6735.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-14",11,9.55,738.15,,0.002,0.001,413.035,0.059,0.02,0.0115,6949.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-15",10,8.3,683.15,,0.002,0.001,376.445,0.059,0.019,0.0124,6334.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-16",9,7.3,328.3,,0.001,0.001,215.205,0.0592,0.012,0.0129,3620.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-17",13,11.28,728,,0.002,0.001,424.92,0.0591,0.021,0.0108,7151.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-18",13,11.3,427.45,,0.002,0.001,300.535,0.0592,0.015,0.0102,5056.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-19",13,11.28,407,,0.001,0.001,289.49,0.0592,0.015,0.0105,4871.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-20",11,9.3,689.85,,0.002,0.001,388.525,0.059,0.019,0.0115,6536.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-21",11,9.55,425,,0.001,0.001,279.475,0.059,0.015,0.0119,4704.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-22",9,6.78,456.93,,0.001,0.001,263.97,0.0592,0.014,0.0131,4443.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-23",9,7.53,483.16,,0.001,0.001,284.854,0.0592,0.014,0.0131,4792.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-24",9,8.05,512,,0.002,0.001,301.21,0.0591,0.016,0.0133,5069.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-25",11,9.3,655.7,,0.002,0.001,373.005,0.0592,0.02,0.0121,6276.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-26",6,4.8,261.5,,0.001,0.001,159.97,0.0592,0.009,0.0067,2689.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-27",10,9.05,706.6,,0.002,0.001,394.165,0.0591,0.021,0.0061,6630.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-28",7,5.06,214.7,,0.001,0.001,143.047,0.0591,0.009,0.0076,2406.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-29",2,1.28,29.5,,0,0.001,25.504,0.059,0.003,0.012,429.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-30",5,3.28,89.6,,0,0.001,71.873,0.0594,0.005,0.0198,1208.669,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-08-31",4,2.28,58,,0,0.001,47.903,0.059,0.004,0.0233,806.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-04",7,6.05,465.71,,0.001,0.001,260.572,0.059,0.014,0.0067,4386.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-05",11,10.8,591.6,,0.002,0.001,364.76,0.0593,0.018,0.0063,6136.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-06",13,11.53,651,,0.002,0.001,395.948,0.0591,0.02,0.0067,6664.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-07",12,8.83,367.31,,0.001,0.001,246.071,0.0591,0.015,0.0103,4141.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-08",11,8.58,376.69,,0.001,0.001,246.082,0.0593,0.015,0.0119,4140.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-09",14,12.33,642.7,,0.002,0.001,397.815,0.0591,0.02,0.0062,6694.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-10",14,9.41,432.45,,0.001,0.001,276.79,0.0592,0.016,0.0121,4658.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-11",12,9.58,594.82,,0.002,0.001,348.977,0.059,0.02,0.0102,5871.159,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-12",9,8.03,263.21,,0.001,0.001,193.336,0.0591,0.01,0.0132,3253.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-13",9,8.03,323.4,,0.001,0.001,217.785,0.059,0.012,0.0062,3664.771,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-14",13,9.87,502.73,,0.002,0.001,313.645,0.0592,0.016,0.0105,5275.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-15",6,4.28,148.9,,0.001,0.001,108.423,0.0592,0.007,0.0165,1824.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-16",10,7.35,392.71,,0.001,0.001,240.623,0.0594,0.013,0.0134,4048.065,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-17",14,12.3,829.06,,0.002,0.001,476.38,0.0591,0.024,0.0102,8016.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-18",13,12.3,936.4,,0.003,0.001,518.84,0.0591,0.026,0.0072,8728.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-19",7,5.3,436.4,,0.001,0.001,237.933,0.059,0.013,0.0161,4004.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-20",8,5.85,341.14,,0.001,0.001,201.77,0.059,0.011,0.01,3394.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-21",7,5.8,310.93,,0.001,0.001,189.419,0.059,0.012,0.0069,3187.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-22",16,13.63,1292.48,,0.003,0.001,683.34,0.0591,0.031,0.0099,11499.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-23",5,3.3,224.74,,0.001,0.001,127.954,0.0592,0.007,0.0184,2153.886,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-24",5,3.3,95.4,,0,0.001,73.55,0.059,0.005,0.019,1238.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-25",9,5.61,244.65,,0.001,0.001,159.687,0.0592,0.009,0.014,2687.661,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-26",5,3.3,95.06,,0,0.001,73.331,0.0592,0.005,0.0198,1234.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-27",5,3.28,108,,0,0.001,78.815,0.0596,0.005,0.0206,1325.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-28",8,7.03,274.86,,0.001,0.001,189.089,0.0594,0.012,0.0071,3180.624,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-29",8,6.53,369.43,,0.001,0.001,222.773,0.0591,0.012,0.0145,3746.029,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-09-30",12,9.4,575.23,,0.002,0.001,338.167,0.059,0.019,0.0148,5690.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-01",8,6.3,202.4,,0.001,0.001,150.114,0.0596,0.009,0.0143,2524.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-02",5,3.55,110.34,,0,0.001,82.479,0.0592,0.006,0.0094,1388.201,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-03",11,9.32,421.23,,0.001,0.001,274.632,0.0591,0.015,0.0131,4623.727,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-04",8,6.55,286.21,,0.001,0.001,189.422,0.0591,0.01,0.0136,3187.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-05",12,10.3,641.74,,0.002,0.001,378.467,0.0591,0.019,0.0112,6371.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-06",18,16.3,793.4,,0.003,0.001,507.614,0.0591,0.025,0.0089,8541.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-07",13,9.61,513.89,,0.002,0.001,317.515,0.0591,0.017,0.0108,5342.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-08",15,13.53,1145.38,,0.003,0.001,629.306,0.0591,0.029,0.0101,10590.087,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-09",17,15.8,1203.97,,0.003,0.001,676.522,0.0591,0.034,0.0093,11384.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-10",17,13.63,990.7,,0.003,0.001,564.707,0.0592,0.028,0.0097,9499.999,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-11",7,5.1,191.26,,0.001,0.001,133.97,0.0591,0.009,0.0149,2253.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-12",9,7.3,521.74,,0.002,0.001,299.084,0.059,0.015,0.0128,5030.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-13",7,5.3,260.4,,0.001,0.001,165.531,0.0594,0.009,0.015,2785.299,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-14",6,4.3,215.57,,0.001,0.001,136.482,0.059,0.008,0.017,2298.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-15",8,6.11,238.2,,0.001,0.001,164.964,0.059,0.01,0.0086,2776.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-16",10,7.61,322.94,,0.001,0.001,216.584,0.059,0.012,0.0072,3647.927,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-17",7,5.3,180.4,,0.001,0.001,132.227,0.0593,0.008,0.0154,2224.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-18",11,8.66,423.39,,0.001,0.001,268.285,0.0592,0.015,0.0066,4513.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-19",14,11.62,729.24,,0.002,0.001,431.298,0.059,0.022,0.0104,7258.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-20",11,7.41,274.73,,0.001,0.001,193.277,0.0592,0.013,0.0117,3253.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-21",7,5.6,230.68,,0.001,0.001,155.148,0.0593,0.011,0.0153,2609.598,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-22",10,7.42,429.49,,0.001,0.001,257.954,0.0591,0.016,0.0095,4339.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-23",7,4.59,136.63,,0.001,0.001,105.778,0.0593,0.008,0.0119,1779.979,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-24",13,9.41,470.81,,0.002,0.001,299.121,0.0592,0.017,0.0102,5033.163,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-25",10,8.09,260.96,,0.001,0.001,196.257,0.0592,0.011,0.0067,3301.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-26",12,8.4,504.01,,0.002,0.001,301.638,0.059,0.017,0.0133,5075.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-27",11,8.86,356.83,,0.001,0.001,244.656,0.0593,0.013,0.0115,4115.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-28",5,3.3,126.59,,0,0.001,88.222,0.0594,0.006,0.0178,1484.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-29",7,4.6,166.71,,0.001,0.001,118.176,0.0593,0.007,0.0081,1988.579,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-30",5,3.29,98.4,,0,0.001,75.323,0.0594,0.005,0.018,1266.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-10-31",4,2.3,59.4,,0,0.001,48.597,0.0593,0.004,0.0228,817.359,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-01",10,6.41,243.48,,0.001,0.001,171.376,0.0593,0.01,0.0125,2883.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-02",6,4.3,212.4,,0.001,0.001,135.329,0.0592,0.008,0.0165,2276.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-03",5,3.3,109.3,,0,0.001,80.73,0.059,0.006,0.0216,1358.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-04",5,3.3,147.7,,0,0.001,97.05,0.0592,0.006,0.02,1633.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-05",11,8.87,433.8,,0.001,0.001,275.45,0.0592,0.015,0.0065,4636.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-06",8,5.85,218.34,,0.001,0.001,151.729,0.0591,0.01,0.0081,2553.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-07",12,8.85,296.15,,0.001,0.001,217.233,0.0594,0.013,0.0101,3654.521,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-08",11,7.44,279.7,,0.001,0.001,194.782,0.0592,0.012,0.0132,3276.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-09",7,4.56,149.28,,0.001,0.001,110.516,0.0593,0.007,0.0193,1859.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-10",12,9.44,333.51,,0.001,0.001,239.546,0.0592,0.015,0.0082,4032.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-11",14,10.96,431.3,,0.002,0.001,298.676,0.0591,0.017,0.0111,5026.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-12",9,5.42,171.42,,0.001,0.001,128.98,0.0591,0.01,0.0098,2169.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-13",13,11.13,621.57,,0.002,0.001,381.04,0.0592,0.022,0.0124,6412.745,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-14",12,8.42,386.69,,0.001,0.001,252.016,0.0593,0.014,0.0068,4240.077,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-15",7,6.28,215.44,,0.001,0.001,156.528,0.0591,0.011,0.0077,2635.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-16",10,7.88,248.48,,0.001,0.001,188.408,0.0593,0.011,0.0135,3170.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-17",7,4.48,128.98,,0.001,0.001,100.882,0.0593,0.007,0.0167,1696.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-18",14,10.38,389.96,,0.001,0.001,274.878,0.0592,0.016,0.012,4624.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-19",5,4.03,118.85,,0,0.001,92.927,0.0594,0.006,0.021,1562.857,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-20",7,5.78,177.58,,0.001,0.001,135.29,0.0591,0.009,0.008,2277.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-21",9,7.08,262.12,,0.001,0.001,185.304,0.0592,0.012,0.0151,3118.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-22",13,11.6,477.1,,0.002,0.001,325.887,0.0592,0.017,0.0068,5484.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-23",12,9.37,587.12,,0.002,0.001,347.606,0.0592,0.018,0.0076,5846.583,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-24",14,13.53,1075.65,,0.003,0.001,603.05,0.0591,0.029,0.0064,10149.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-25",3,1.78,49.62,,0,0.001,39.355,0.0597,0.003,0.0137,661.534,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-26",2,1.55,40.05,,0,0.001,32.805,0.059,0.003,0.0105,551.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-27",7,4.58,120.2,,0,0.001,98.524,0.0593,0.007,0.0126,1657.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-28",5,3.3,94.9,,0,0.001,74.7,0.0594,0.006,0.0216,1256.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-29",9,6.38,216.15,,0.001,0.001,158.669,0.0592,0.011,0.0089,2669.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-11-30",6,4.8,140.3,,0.001,0.001,110.26,0.0593,0.007,0.0185,1855.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-01",9,7.38,272.01,,0.001,0.001,191.477,0.0592,0.013,0.0086,3223.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-02",6,5.03,218.53,,0.001,0.001,145.875,0.059,0.008,0.0075,2454.857,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-03",9,8.13,600.28,,0.002,0.001,339.686,0.0592,0.02,0.0074,5715.059,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-04",10,8.15,419.72,,0.001,0.001,260.931,0.0592,0.015,0.0095,4389.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-05",12,10.35,318.13,,0.001,0.001,240.625,0.0591,0.017,0.0093,4047.237,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-06",7,6.03,175.82,,0.001,0.001,135.577,0.0591,0.008,0.0156,2283.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-07",11,9.65,516.88,,0.002,0.001,314.803,0.0593,0.018,0.013,5295.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-08",9,5.56,216.56,,0.001,0.001,146.714,0.0592,0.01,0.0221,2468.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-09",13,8.13,227.75,,0.001,0.001,177.237,0.0595,0.012,0.0192,2979.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-10",12,7.38,215.42,,0.001,0.001,164.78,0.0593,0.011,0.0201,2773.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-11",8,5.04,154.94,,0.001,0.001,116.076,0.0591,0.01,0.0263,1952.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-12",13,10.63,302.09,,0.001,0.001,233.849,0.0595,0.014,0.0128,3935.346,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-13",13,11.28,388.5,,0.001,0.001,280.362,0.0591,0.015,0.0115,4716.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-17",5,3.28,97.6,,0,0.001,74.784,0.059,0.005,0.021,1258.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-18",5,3.08,97.48,,0,0.001,72.325,0.0594,0.006,0.0114,1215.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-21",4,2.27,151.48,,0,0.001,85.762,0.059,0.007,0.0228,1443.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-22",4,2.8,96.6,,0,0.001,68.7,0.0593,0.005,0.0238,1156.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-28",4,2.3,107.98,,0,0.001,68.028,0.059,0.005,0.024,1144.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-29",4,2.3,149.92,,0,0.001,85.94,0.059,0.007,0.0253,1445.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"10",,"2020-12-31",6,4.4,254.86,,0.001,0.001,149.511,0.0592,0.01,0.0187,2515.087,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-03",3,2.07,135.73,,0,0.001,79.018,0.059,0.006,0.0153,1330.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-06",11,8.33,464.57,,0.001,0.001,285.684,0.0593,0.021,0.0105,4806.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-07",11,8.52,587.7,,0.002,0.001,338.234,0.0591,0.022,0.0093,5691.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-08",10,7.85,538.08,,0.002,0.001,308.114,0.0592,0.02,0.0138,5183.354,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-09",4,2.78,120.36,,0,0.001,79.182,0.0593,0.006,0.022,1332.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-10",11,7.49,300.39,,0.001,0.001,204.553,0.0591,0.014,0.0156,3443.113,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-13",3,1.53,37.4,,0,0.001,30.992,0.059,0.003,0.0163,522.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-14",6,3.02,119.62,,0,0.001,81.344,0.059,0.007,0.0197,1370.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-15",6,4.28,104.5,,0,0.001,88.092,0.0593,0.006,0.017,1482.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-16",3,1.78,44.6,,0,0.001,36.864,0.0593,0.003,0.012,620.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-17",2,1.3,27.8,,0,0.001,24.498,0.059,0.003,0.0145,412.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-20",6,4.55,335.9,,0.001,0.001,190.38,0.0592,0.012,0.011,3202.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-23",4,2.8,69.39,,0,0.001,58.318,0.0593,0.005,0.0128,980.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-29",3,1.58,103.98,,0,0.001,60.582,0.059,0.006,0.03,1020.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-30",10,9.3,721.44,,0.002,0.001,403.642,0.059,0.023,0.0079,6790.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-01-31",6,4.18,196.58,,0.001,0.001,126.626,0.0593,0.01,0.0188,2130.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-01",3,2.12,170.68,,0,0.001,95.1,0.059,0.007,0.028,1599.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-02",12,9.48,277,,0.001,0.001,215.366,0.0593,0.013,0.0121,3623.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-03",6,4.93,212.86,,0.001,0.001,140.414,0.059,0.012,0.0105,2364.751,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-04",3,1.57,90.58,,0,0.001,54.729,0.0597,0.005,0.0297,921.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-05",3,1.78,147.88,,0,0.001,80.986,0.059,0.007,0.029,1362.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-06",3,1.3,69.2,,0,0.001,42.9,0.0593,0.004,0.0263,721.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-07",6,4.63,312.71,,0.001,0.001,182.425,0.0592,0.012,0.0147,3068.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-09",16,14.28,433.6,,0.002,0.001,331.698,0.0592,0.02,0.0108,5583.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-10",14,12.52,359,,0.001,0.001,282.408,0.0591,0.017,0.0107,4752.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-11",7,5.28,216.5,,0.001,0.001,147.286,0.0591,0.01,0.0156,2478.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-13",17,16.03,840.5,,0.003,0.001,527.336,0.0591,0.031,0.0074,8875.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-15",11,9.3,340.98,,0.001,0.001,243.758,0.0592,0.015,0.0139,4101.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-16",9,7.3,195.8,,0.001,0.001,159.294,0.0591,0.01,0.0149,2680.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-17",3,1.8,115.6,,0,0.001,66.976,0.059,0.006,0.011,1127.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-19",8,6.68,303.58,,0.001,0.001,197.133,0.0593,0.014,0.0113,3315.542,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-21",3,2.38,107.22,,0,0.001,69.765,0.059,0.006,0.0133,1173.757,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-23",10,8.32,250.2,,0.001,0.001,193.672,0.0592,0.012,0.0142,3258.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-24",8,6.19,255.55,,0.001,0.001,173.531,0.0593,0.012,0.0105,2919.857,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-25",11,10.3,914.08,,0.003,0.001,495.596,0.059,0.03,0.0077,8337.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-26",9,7.59,578.39,,0.002,0.001,321.506,0.059,0.021,0.0086,5411.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-27",14,11.58,538.2,,0.002,0.001,350.192,0.0591,0.021,0.0131,5893.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-28",12,8.85,388.06,,0.001,0.001,257.212,0.0593,0.016,0.0139,4328.581,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-02-29",11,9.3,497.98,,0.002,0.001,310.602,0.0592,0.019,0.013,5228.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-01",14,12.8,941.25,,0.003,0.001,532.555,0.0591,0.031,0.0083,8960.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-02",17,15.55,1048.67,,0.003,0.001,605.122,0.0591,0.034,0.0104,10183.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-03",5,3.88,163.41,,0.001,0.001,108.524,0.0592,0.008,0.0108,1826.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-04",6,4.1,117.49,,0,0.001,91.602,0.0592,0.008,0.0128,1540.603,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-05",10,7.67,405.52,,0.001,0.001,250.582,0.0592,0.017,0.0154,4216.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-07",11,10.05,297.37,,0.001,0.001,232.318,0.0593,0.015,0.0131,3908.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-08",12,10.29,274.8,,0.001,0.001,224.753,0.0593,0.013,0.0123,3780.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-09",13,10.58,393.74,,0.001,0.001,278.756,0.0594,0.018,0.0128,4687.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-10",6,3.59,124.64,,0,0.001,89.871,0.0592,0.007,0.0182,1511.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-12",8,5.7,448.22,,0.001,0.001,250.702,0.0593,0.017,0.0141,4218.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-13",5,4.88,370.84,,0.001,0.001,209.635,0.059,0.014,0.0078,3528.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-14",15,13.88,790.52,,0.002,0.001,483.392,0.059,0.029,0.0098,8136.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-15",15,13.8,562.72,,0.002,0.001,384.888,0.0591,0.023,0.0111,6476.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-16",13,11.54,616.1,,0.002,0.001,384.308,0.0593,0.023,0.0118,6463.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-25",6,4.3,127.92,,0.001,0.001,99.302,0.0592,0.007,0.0187,1670.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-27",2,1.54,33.28,,0,0.001,29.452,0.0595,0.003,0.015,495.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-01",9,7.29,193.92,,0.001,0.001,156.484,0.059,0.011,0.0148,2634.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-04",8,6.29,163.68,,0.001,0.001,133.068,0.0593,0.009,0.0165,2241.361,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-05",11,9.29,291.92,,0.001,0.001,218.355,0.0593,0.013,0.0129,3673.362,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-06",8,5.15,185.77,,0.001,0.001,131.045,0.0593,0.01,0.0173,2206.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-11",6,4.8,295.6,,0.001,0.001,174.722,0.0592,0.012,0.0093,2939.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-13",4,2.45,183.28,,0.001,0.001,101.2,0.0593,0.007,0.0165,1702.691,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-14",3,2.54,195.34,,0.001,0.001,107.964,0.0593,0.009,0.0107,1815.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-16",3,2.05,46.37,,0,0.001,40.121,0.0597,0.004,0.0117,674.381,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-19",1,0.48,0,,0,0.001,3.696,0.059,0.001,0.047,62.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-28",12,10.3,1066.08,,0.003,0.001,559.502,0.0591,0.041,0.0142,9415.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-04-30",2,1.28,31.23,,0,0.001,26.178,0.059,0.003,0.0135,440.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-01",6,4.19,301.73,,0.001,0.001,172.285,0.059,0.013,0.0125,2899.295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-02",5,4.05,243.74,,0.001,0.001,146.121,0.0592,0.01,0.0192,2457.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-03",4,3.3,253.14,,0.001,0.001,140.852,0.059,0.01,0.0118,2370.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-04",7,4.2,291.29,,0.001,0.001,167.767,0.0591,0.013,0.022,2822.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-05",6,3.1,115.02,,0,0.001,80.305,0.0592,0.007,0.021,1351.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-06",10,5.22,212.8,,0.001,0.001,143.418,0.0593,0.011,0.0191,2414.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-07",3,1.45,42.33,,0,0.001,32.668,0.0597,0.003,0.0263,548.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-09",6,5.14,325.26,,0.001,0.001,189.506,0.0592,0.013,0.0082,3189.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-10",8,4.58,117.42,,0,0.001,95.548,0.0594,0.008,0.0213,1607.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-11",5,3.55,274.99,,0.001,0.001,152.86,0.059,0.01,0.0112,2573.373,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-12",9,7.29,332.16,,0.001,0.001,216.773,0.0594,0.014,0.0141,3645.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-13",3,2.28,155.56,,0,0.001,89.029,0.059,0.007,0.01,1497.223,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-14",5,4.05,191.27,,0.001,0.001,123.073,0.059,0.009,0.0082,2071.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-15",5,3.87,105.3,,0,0.001,83.912,0.0592,0.006,0.009,1411.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-16",5,3.62,215.1,,0.001,0.001,128.126,0.0592,0.009,0.0172,2155.122,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-17",2,1.55,64.8,,0,0.001,42.747,0.059,0.004,0.014,719.715,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-21",3,2.64,237.66,,0.001,0.001,128.325,0.059,0.01,0.0087,2159.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-22",3,2.12,149.36,,0,0.001,84.868,0.0593,0.007,0.023,1428.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-24",6,4.29,225.92,,0.001,0.001,142.477,0.0592,0.009,0.0175,2396.657,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-25",6,4.3,343.95,,0.001,0.001,192.476,0.0592,0.013,0.017,3240.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-26",5,3.25,250.92,,0.001,0.001,141.906,0.059,0.009,0.0194,2386.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-27",6,5.03,251.2,,0.001,0.001,159.779,0.0592,0.011,0.0082,2689.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-28",16,12.61,885.42,,0.003,0.001,510.611,0.0591,0.032,0.0138,8593.907,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-29",5,3.37,93.4,,0,0.001,74.566,0.0596,0.006,0.0174,1254.053,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-01",6,3.55,104.21,,0,0.001,80.81,0.0592,0.007,0.0183,1360.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-02",6,4.78,150.08,,0.001,0.001,114.544,0.0593,0.008,0.0173,1927.707,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-03",7,5.28,136.21,,0.001,0.001,113.752,0.059,0.008,0.0156,1916.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-04",3,1.56,96.54,,0,0.001,57.368,0.0593,0.005,0.015,966.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-10",6,4.28,132.08,,0.001,0.001,101.841,0.0593,0.008,0.0187,1712.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-11",5,3.28,82.47,,0,0.001,70.436,0.0594,0.005,0.02,1184.949,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-14",3,2.53,114.57,,0,0.001,76.516,0.059,0.009,0.011,1287.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-15",3,1.78,70.61,,0,0.001,49.3,0.059,0.005,0.011,829.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-17",2,1.28,27.47,,0,0.001,24.802,0.059,0.003,0.014,417.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-20",2,1.87,143.79,,0,0.001,82.228,0.0595,0.007,0.01,1383.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-22",6,4.78,166.69,,0.001,0.001,122.971,0.0593,0.008,0.0177,2069.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-23",6,4.53,132.94,,0.001,0.001,105.401,0.0592,0.007,0.0177,1773.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-24",5,4.03,155.24,,0.001,0.001,109.414,0.059,0.008,0.0204,1841.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-26",7,6.28,418.52,,0.001,0.001,247.352,0.0593,0.015,0.008,4160.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-27",8,6.56,421.82,,0.001,0.001,251.257,0.0591,0.016,0.0081,4226.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-28",2,1.54,46.02,,0,0.001,35.514,0.059,0.004,0.0125,597.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-06-30",3,1.88,157.48,,0,0.001,88.089,0.059,0.007,0.0223,1481.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-01",4,2.88,219.86,,0.001,0.001,125.07,0.059,0.01,0.0203,2104.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-02",3,1.63,85.38,,0,0.001,53.53,0.059,0.005,0.0213,900.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-03",3,1.39,78.84,,0,0.001,48.482,0.059,0.005,0.023,815.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-04",4,3.3,283.2,,0.001,0.001,157.02,0.059,0.011,0.0095,2643.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-05",6,5.37,322.07,,0.001,0.001,196.145,0.0593,0.012,0.0087,3298.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-06",5,4.82,433.52,,0.001,0.001,237.548,0.059,0.017,0.0086,3999.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-07",4,3.3,306.54,,0.001,0.001,166.952,0.059,0.012,0.0085,2809.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-09",5,4.05,374.85,,0.001,0.001,204.775,0.059,0.014,0.0116,3445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-10",10,8.55,630.3,,0.002,0.001,362.331,0.0591,0.021,0.0138,6095.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-11",10,8.62,670.32,,0.002,0.001,379.37,0.0592,0.023,0.0085,6384.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-12",10,8.58,653.76,,0.002,0.001,372.662,0.059,0.023,0.0144,6270.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-13",9,7.83,614.32,,0.002,0.001,345.007,0.059,0.021,0.0153,5806.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-15",2,1.32,98.94,,0,0.001,56.2,0.059,0.006,0.0125,945.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-16",3,1.8,142.1,,0,0.001,79.615,0.059,0.007,0.011,1339.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-21",3,2.3,100.2,,0,0.001,66.83,0.059,0.006,0.01,1124.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-22",4,3.05,101.4,,0,0.001,75.575,0.0595,0.006,0.01,1270.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-23",6,4.3,129.55,,0.001,0.001,100.69,0.059,0.007,0.0173,1693.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-24",6,5.03,130.5,,0.001,0.001,108.224,0.0595,0.008,0.0087,1821.045,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-25",6,4.3,152.55,,0.001,0.001,111.705,0.0595,0.008,0.0175,1879.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-26",7,5.55,175.55,,0.001,0.001,134.545,0.0593,0.009,0.0156,2262.615,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-27",7,4.85,224.05,,0.001,0.001,146.6,0.0591,0.01,0.0151,2467.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-28",8,6.26,315.47,,0.001,0.001,203.054,0.0593,0.013,0.0144,3417.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-29",8,6.3,468.55,,0.001,0.001,269.95,0.0593,0.017,0.0143,4542.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-30",10,8.55,688,,0.002,0.001,386.195,0.0591,0.023,0.0127,6496.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-07-31",11,10.03,737.57,,0.002,0.001,424.023,0.0591,0.025,0.0085,7134.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-01",8,6.3,412.55,,0.001,0.001,243.36,0.059,0.015,0.014,4095.035,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-02",7,4.58,119.5,,0,0.001,97.79,0.059,0.007,0.0169,1647.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-03",8,6.26,164.34,,0.001,0.001,135.589,0.0594,0.009,0.0144,2281.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-04",6,4.28,141.55,,0.001,0.001,105.406,0.059,0.007,0.017,1773.201,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-05",6,4.55,122.35,,0.001,0.001,99.72,0.0592,0.007,0.017,1678.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-06",5,3.28,83.55,,0,0.001,69.421,0.0594,0.005,0.019,1167.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-07",6,4.28,121.55,,0,0.001,96.751,0.0592,0.007,0.0172,1628.281,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-08",5,3.28,99.7,,0,0.001,76.796,0.059,0.006,0.0196,1293.371,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-09",6,5.03,243.1,,0.001,0.001,155.351,0.0593,0.01,0.0077,2614.113,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-10",7,5.36,221.98,,0.001,0.001,150.354,0.0593,0.01,0.0126,2531.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-11",5,3.3,209.55,,0.001,0.001,123.345,0.0592,0.008,0.0186,2074.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-12",5,4.38,369.36,,0.001,0.001,203.766,0.059,0.014,0.0084,3428.559,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-13",11,10.05,804.5,,0.002,0.001,446.635,0.0591,0.026,0.0071,7515.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-14",13,11.28,800.7,,0.002,0.001,458.981,0.0592,0.026,0.011,7723.682,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-15",11,9.3,700.7,,0.002,0.001,396.835,0.059,0.023,0.012,6678.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-16",10,7.33,328.7,,0.001,0.001,216.486,0.0593,0.014,0.0134,3642.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-17",11,9.36,671.29,,0.002,0.001,383.642,0.059,0.023,0.0105,6456.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-18",13,11.28,405.55,,0.001,0.001,292.151,0.0592,0.018,0.0115,4915.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-19",14,12.28,551.85,,0.002,0.001,364.386,0.0591,0.022,0.0114,6134.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-20",12,10.3,773.7,,0.002,0.001,437.465,0.0591,0.026,0.0123,7363.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-21",13,11.3,598.7,,0.002,0.001,373.88,0.0593,0.023,0.012,6289.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-22",12,10.32,610.15,,0.002,0.001,369.074,0.0591,0.022,0.0119,6212.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-23",12,9.93,705.19,,0.002,0.001,405.855,0.0591,0.024,0.0103,6831.808,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-24",13,10.85,699.74,,0.002,0.001,413.252,0.059,0.025,0.0119,6954.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-25",13,10.58,851.7,,0.002,0.001,474.763,0.0592,0.028,0.0122,7986.581,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-26",9,7.26,524.47,,0.002,0.001,300.028,0.0591,0.018,0.0142,5048.591,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-27",10,9.05,829.6,,0.002,0.001,447.17,0.059,0.026,0.0072,7523.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-28",8,4.88,214.75,,0.001,0.001,142.431,0.0591,0.011,0.0229,2397.817,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-29",6,4.28,132,,0.001,0.001,101.306,0.0595,0.007,0.017,1704.607,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-30",4,2.28,59.15,,0,0.001,48.964,0.0595,0.005,0.0235,823.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-08-31",5,3.28,83.7,,0,0.001,69.526,0.059,0.006,0.0202,1170.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-01",5,3.28,113.55,,0,0.001,83.736,0.0592,0.006,0.0196,1408.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-02",5,3.3,93.55,,0,0.001,74.335,0.0592,0.006,0.0208,1250.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-03",8,6.28,436.55,,0.001,0.001,253.206,0.059,0.017,0.016,4261.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-04",9,7.36,499.52,,0.001,0.001,289.947,0.0591,0.018,0.0117,4878.978,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-05",12,11.03,977.9,,0.003,0.001,533.948,0.059,0.034,0.0078,8984.711,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-06",16,14.28,913.7,,0.003,0.001,541.511,0.0592,0.033,0.0114,9111.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-07",10,8.3,302.9,,0.001,0.001,216.805,0.059,0.014,0.0137,3646.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-08",13,9.6,483.68,,0.002,0.001,305.962,0.0592,0.02,0.0159,5149.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-09",10,8.61,307.04,,0.001,0.001,221.568,0.0593,0.015,0.0087,3726.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-10",8,5.58,175.2,,0.001,0.001,132.343,0.0591,0.01,0.0169,2226.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-11",10,7.58,287.8,,0.001,0.001,202.598,0.0591,0.013,0.0153,3409.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-12",8,6.28,333.75,,0.001,0.001,207.448,0.0593,0.014,0.0166,3490.469,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-13",9,7.61,323.35,,0.001,0.001,217.148,0.0593,0.015,0.0122,3653.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-14",7,5.61,200.7,,0.001,0.001,145.202,0.0593,0.012,0.0137,2442.823,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-15",8,6.36,243.87,,0.001,0.001,172.663,0.0593,0.013,0.0128,2904.303,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-16",7,5.38,196.67,,0.001,0.001,141.261,0.0593,0.011,0.0146,2376.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-17",11,9.28,456.75,,0.001,0.001,294.233,0.059,0.019,0.014,4949.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-18",12,10.6,505.8,,0.002,0.001,326.032,0.0591,0.022,0.0113,5487.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-19",10,9.03,610.2,,0.002,0.001,352.668,0.0591,0.023,0.0079,5935.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-20",10,8.28,460.75,,0.001,0.001,280.363,0.0591,0.018,0.0145,4719.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-21",10,8.3,355.08,,0.001,0.001,237.42,0.0592,0.016,0.0145,3996.267,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-22",10,7.67,343.17,,0.001,0.001,225.128,0.0593,0.015,0.0094,3787.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-23",6,4.3,229.08,,0.001,0.001,141.854,0.059,0.01,0.0198,2387.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-24",11,8.83,330.93,,0.001,0.001,233.119,0.0591,0.019,0.0103,3923.183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-25",7,5.3,234.25,,0.001,0.001,155.152,0.0591,0.011,0.016,2611.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-26",4,2.28,71.75,,0,0.001,54.593,0.0593,0.005,0.0233,917.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-27",3,1.95,61.03,,0,0.001,46.258,0.059,0.005,0.0127,778.709,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-28",4,3.1,104.32,,0,0.001,76.96,0.0595,0.007,0.0108,1294.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-29",8,4.91,174.34,,0.001,0.001,125.397,0.0591,0.01,0.0169,2110.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-09-30",12,9.35,345.78,,0.001,0.001,246.431,0.0593,0.018,0.0134,4147.122,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-01",10,7.91,270.5,,0.001,0.001,199.121,0.0591,0.015,0.0141,3351.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-02",5,3.3,106.91,,0,0.001,80.235,0.059,0.007,0.0218,1351.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-04",5,3.89,171.99,,0.001,0.001,113.993,0.0594,0.01,0.0104,1916.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-05",7,6.6,292.4,,0.001,0.001,195.54,0.0591,0.013,0.0081,3290.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-06",10,9.11,367.04,,0.001,0.001,255.39,0.0592,0.018,0.0087,4296.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-07",11,9.88,394.9,,0.001,0.001,275.717,0.0591,0.02,0.0105,4642.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-08",10,7.81,311.33,,0.001,0.001,216.338,0.0592,0.015,0.0142,3638.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-09",9,5.94,222.04,,0.001,0.001,157.235,0.0592,0.013,0.0162,2646.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-10",10,7.05,330.33,,0.001,0.001,216.968,0.0592,0.016,0.014,3651.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-11",4,2.28,71.75,,0,0.001,55.021,0.059,0.005,0.0235,926.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-12",9,5.3,235.25,,0.001,0.001,155.82,0.0592,0.014,0.0137,2621.642,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-13",8,4.55,159.65,,0.001,0.001,116.667,0.0593,0.01,0.0208,1963.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-14",8,5.93,220.63,,0.001,0.001,157.796,0.0591,0.011,0.0123,2653.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-15",9,7.86,329.34,,0.001,0.001,226.216,0.0592,0.016,0.0086,3805.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-16",6,4.88,189.25,,0.001,0.001,132.589,0.0593,0.011,0.0097,2231.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-17",7,4.16,141.31,,0.001,0.001,104.441,0.059,0.009,0.0164,1758.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-18",11,9.35,452.64,,0.001,0.001,292.275,0.0594,0.022,0.0089,4916.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-19",10,7.45,404.65,,0.001,0.001,250.765,0.0594,0.018,0.011,4220,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-20",9,6.9,261.74,,0.001,0.001,185.296,0.0592,0.014,0.0098,3119.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-21",4,3.04,120.32,,0,0.001,83.824,0.0595,0.007,0.01,1411.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-22",8,5.84,206.41,,0.001,0.001,149.755,0.0593,0.011,0.015,2519.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-23",12,7.66,252.6,,0.001,0.001,187.221,0.0593,0.014,0.0153,3150.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-24",6,3.54,115.08,,0,0.001,86.126,0.0593,0.007,0.0175,1449.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-25",6,5,182.25,,0.001,0.001,130.125,0.0593,0.01,0.013,2190.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-26",12,8.07,409.46,,0.001,0.001,259.504,0.0592,0.019,0.0173,4366.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-27",5,3.61,227.77,,0.001,0.001,136.019,0.059,0.01,0.0132,2289.859,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-28",6,2.91,109.32,,0,0.001,77.345,0.0593,0.007,0.0147,1301.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-29",7,4.93,246,,0.001,0.001,157.534,0.0594,0.012,0.01,2650.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-30",6,3.65,142.36,,0,0.001,98.419,0.0592,0.008,0.0142,1656.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-10-31",4,2.6,71.5,,0,0.001,57.23,0.0593,0.005,0.012,961.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-01",7,5.37,263.75,,0.001,0.001,171.323,0.0593,0.013,0.0129,2881.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-02",10,6.3,301.68,,0.001,0.001,195.116,0.0591,0.014,0.0178,3285.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-03",11,5.25,174.72,,0.001,0.001,129.124,0.0592,0.012,0.0217,2173.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-04",12,8.38,265.8,,0.001,0.001,202.166,0.0593,0.014,0.0087,3401.472,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-05",14,10.93,531.48,,0.002,0.001,341.657,0.0591,0.022,0.0102,5746.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-06",8,6.08,219.58,,0.001,0.001,156.136,0.0591,0.011,0.01,2626.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-07",10,6.86,253.77,,0.001,0.001,179.442,0.0592,0.014,0.0114,3019.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-08",15,10.83,456.12,,0.002,0.001,307.532,0.0593,0.021,0.0135,5173.734,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-09",13,9.3,335.69,,0.001,0.001,238.828,0.0593,0.02,0.0177,4016.807,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-10",17,14.91,485.04,,0.002,0.001,364.159,0.0591,0.026,0.009,6129.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-11",15,10.23,360.77,,0.001,0.001,260.662,0.0592,0.02,0.0111,4387.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-12",13,7.97,214.37,,0.001,0.001,173.754,0.0592,0.015,0.0192,2925.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-13",14,10.48,357.17,,0.001,0.001,262.682,0.0591,0.021,0.0166,4418.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-14",14,11.71,501.56,,0.002,0.001,336.902,0.0591,0.023,0.0087,5669.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-15",16,10.48,293.66,,0.001,0.001,232.847,0.0591,0.017,0.0128,3920.477,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-16",8,6.73,196.05,,0.001,0.001,154.384,0.0593,0.012,0.0151,2598.825,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-17",9,5.93,189.43,,0.001,0.001,142.528,0.0593,0.012,0.0173,2396.891,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-18",5,3.13,75.73,,0,0.001,64.682,0.0592,0.007,0.0144,1088.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-19",8,5.66,185.28,,0.001,0.001,137.584,0.0591,0.013,0.0165,2315.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-20",10,8.07,254.08,,0.001,0.001,192.955,0.059,0.016,0.0148,3249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-21",11,8.46,247.62,,0.001,0.001,194.154,0.059,0.016,0.0144,3266.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-22",16,14.55,532.74,,0.002,0.001,382.297,0.0592,0.026,0.0093,6432.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-23",17,12.85,562.44,,0.002,0.001,376.122,0.059,0.026,0.0113,6331.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-24",14,11.13,542.88,,0.002,0.001,352.793,0.0594,0.028,0.0138,5934.731,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-25",6,3.98,167.38,,0.001,0.001,113.58,0.0595,0.009,0.0168,1909.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-26",9,6.13,182.23,,0.001,0.001,141.491,0.0593,0.012,0.0156,2381.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-27",8,4.64,115.61,,0,0.001,97.253,0.0593,0.009,0.0164,1635.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-28",7,5.35,160.83,,0.001,0.001,124.474,0.0596,0.011,0.0176,2092.574,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-29",13,9.84,388.09,,0.001,0.001,270.406,0.0592,0.019,0.0133,4551.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-11-30",8,5.09,171.26,,0.001,0.001,125.625,0.0591,0.012,0.0153,2113.534,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-01",12,9.75,392.75,,0.001,0.001,270.372,0.0591,0.02,0.0115,4549.494,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-02",9,6.16,197.66,,0.001,0.001,149.062,0.0591,0.011,0.0143,2507.454,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-03",6,4.38,237.72,,0.001,0.001,147.448,0.059,0.011,0.0183,2480.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-04",10,6.63,206.87,,0.001,0.001,156.167,0.0593,0.014,0.0191,2627.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-05",5,4.03,108.05,,0,0.001,86.828,0.0596,0.008,0.0116,1459.591,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-06",5,3.78,125.58,,0,0.001,92.64,0.0592,0.008,0.0118,1558.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-07",5,3.69,117.9,,0,0.001,88.319,0.0594,0.008,0.0122,1484.359,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-08",6,2.91,103.06,,0,0.001,73.099,0.059,0.007,0.0185,1230.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-09",8,6.28,315.48,,0.001,0.001,197.952,0.0593,0.013,0.0154,3331.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-10",6,4.53,135.88,,0.001,0.001,103.902,0.0595,0.009,0.0127,1748.107,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-11",12,8.58,326,,0.001,0.001,227.022,0.0592,0.018,0.0178,3820.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-15",7,6.03,196.43,,0.001,0.001,145.087,0.059,0.012,0.0124,2441.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-16",6,4.87,186.5,,0.001,0.001,130.643,0.059,0.011,0.0177,2200.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-17",3,1.28,31.48,,0,0.001,26.096,0.0593,0.004,0.0297,439.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-18",5,3.78,159.54,,0.001,0.001,106.656,0.059,0.008,0.0194,1794.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-20",5,4.28,260.49,,0.001,0.001,154.36,0.0592,0.012,0.01,2597.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-21",10,7.86,394.76,,0.001,0.001,249.682,0.0592,0.018,0.0098,4201.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-22",5,3.36,130.36,,0,0.001,90.456,0.0594,0.008,0.0178,1521.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-28",5,2.58,123.88,,0,0.001,77.868,0.0592,0.008,0.0216,1310.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-29",3,1.28,40.8,,0,0.001,30.494,0.059,0.004,0.0303,512.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-30",5,3.53,185.26,,0.001,0.001,113.988,0.0592,0.009,0.0192,1917.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"6",,"2020-12-31",3,2.03,61.87,,0,0.001,47.142,0.0593,0.005,0.03,792.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-02",2,1.3,33.3,,0,0.001,27.45,0.0595,0.004,0.016,461.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-03",8,7.07,518.78,,0.001,0.001,295.587,0.0593,0.017,0.0101,4971.409,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-06",13,9.61,494.43,,0.002,0.001,312.112,0.0592,0.021,0.0095,5254.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-07",14,11.43,799.08,,0.002,0.001,461.255,0.059,0.028,0.009,7761.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-08",10,7.85,537.08,,0.002,0.001,308.502,0.0591,0.02,0.016,5192.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-09",8,6.68,319.33,,0.001,0.001,205.615,0.0593,0.015,0.0084,3456.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-10",12,8.64,383.58,,0.001,0.001,253.511,0.0592,0.018,0.0153,4265.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-14",9,5.81,174.98,,0.001,0.001,134.314,0.0593,0.012,0.0284,2259.783,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-17",2,1.28,27.32,,0,0.001,24.464,0.059,0.003,0.015,411.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-20",2,1.08,68.76,,0,0.001,40.014,0.059,0.004,0.044,674.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-23",1,0.5,7.5,,0,0.001,7.9,0.06,0.002,0.032,132.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-25",2,0.85,14.82,,0,0.001,14.657,0.0595,0.003,0.013,246.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-26",1,0.63,10.71,,0,0.001,10.71,0.059,0.002,0.024,180.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-27",2,0.44,5.56,,0,0.001,6.368,0.06,0.003,0.048,106.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-08",3,1.25,69.95,,0,0.001,42.649,0.0593,0.005,0.0367,718.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-09",16,14.28,432.6,,0.002,0.001,332.306,0.0594,0.021,0.0129,5589.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-10",16,14.63,469.04,,0.002,0.001,351.563,0.0592,0.022,0.0126,5914.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-11",7,5.28,216.5,,0.001,0.001,147.606,0.0591,0.01,0.0197,2484.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-13",17,16.05,839.23,,0.003,0.001,529.022,0.0591,0.031,0.0072,8901.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-16",9,7.3,195.8,,0.001,0.001,159.582,0.0593,0.011,0.0167,2686.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-17",3,1.82,115.82,,0,0.001,67.426,0.059,0.006,0.0107,1133.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-19",6,5.38,245.56,,0.001,0.001,159.736,0.059,0.011,0.0102,2688.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-23",10,8.32,249.2,,0.001,0.001,193.964,0.0592,0.012,0.0148,3264.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-24",3,1.62,65,,0,0.001,44.76,0.0597,0.005,0.0277,752.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-25",9,8.38,757.96,,0.002,0.001,411.114,0.059,0.026,0.0079,6916.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-26",7,6.27,540.01,,0.001,0.001,292.927,0.059,0.019,0.0089,4930.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-27",14,11.58,538.32,,0.002,0.001,350.652,0.0592,0.021,0.0154,5898.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-28",8,4.67,218.52,,0.001,0.001,140.46,0.0591,0.012,0.0261,2364.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-02-29",11,9.32,498.2,,0.002,0.001,311.272,0.059,0.019,0.0155,5238.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-01",13,11.63,830.85,,0.002,0.001,473.708,0.0591,0.028,0.0115,7970.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-02",16,15.3,1035.24,,0.003,0.001,599.293,0.0592,0.035,0.0073,10080.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-05",8,6.8,499.4,,0.001,0.001,281.368,0.0591,0.017,0.0174,4732.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-07",15,12.6,419.79,,0.002,0.001,312.696,0.0593,0.02,0.0132,5259.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-08",16,13.35,482.24,,0.002,0.001,345.825,0.0593,0.02,0.0122,5818.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-09",13,10.59,393.86,,0.001,0.001,278.939,0.0592,0.019,0.0145,4694.019,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-10",6,3.56,122.64,,0,0.001,89.27,0.0593,0.007,0.0213,1502.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-11",3,2.3,179.22,,0.001,0.001,100.412,0.059,0.008,0.0103,1691.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-12",9,6.85,559.64,,0.002,0.001,311.063,0.059,0.02,0.01,5236.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-13",18,17.8,1030.9,,0.003,0.001,629.453,0.0591,0.04,0.0074,10597.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-14",16,15.05,901.99,,0.003,0.001,544.652,0.0591,0.033,0.0081,9164.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-15",4,3.38,217.92,,0.001,0.001,128.084,0.059,0.01,0.0093,2154.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-16",16,13.56,660.8,,0.002,0.001,424.21,0.0592,0.026,0.0128,7138.698,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-19",5,3.3,252.8,,0.001,0.001,142.254,0.0592,0.01,0.0236,2393.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-21",11,9.3,309.8,,0.001,0.001,228.942,0.0591,0.014,0.0139,3855.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-22",10,9.04,286,,0.001,0.001,215.268,0.0594,0.014,0.015,3621.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-24",3,1.79,76.98,,0,0.001,51.005,0.0593,0.005,0.0363,857.734,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-25",6,4.3,127.92,,0.001,0.001,99.302,0.0592,0.008,0.0212,1672.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-26",6,4.83,334.82,,0.001,0.001,192.689,0.059,0.013,0.0102,3241.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-27",2,1.54,33.28,,0,0.001,29.514,0.0595,0.003,0.0145,496.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-28",11,9.29,289.8,,0.001,0.001,219.936,0.0591,0.014,0.0148,3701.919,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-29",6,4.54,125.64,,0.001,0.001,100.87,0.0593,0.007,0.0205,1697.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-06",8,5.15,185.77,,0.001,0.001,131.514,0.0595,0.01,0.0174,2210.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-13",4,2.45,183.28,,0.001,0.001,101.4,0.0593,0.008,0.0163,1706.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-14",3,2.55,194.83,,0.001,0.001,107.823,0.059,0.012,0.016,1814.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-16",3,2.05,46.37,,0,0.001,40.226,0.0593,0.004,0.0123,676.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-20",2,1.3,52.42,,0,0.001,35.236,0.059,0.005,0.014,593.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-21",4,2.79,202.58,,0.001,0.001,114.502,0.059,0.009,0.0095,1926.458,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-24",7,4.97,267.52,,0.001,0.001,164.099,0.0593,0.012,0.015,2760.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-29",13,11.3,1155.22,,0.003,0.001,608.244,0.059,0.044,0.0154,10236.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-01",4,2.89,253.68,,0.001,0.001,138.465,0.059,0.011,0.0088,2331.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-02",3,2.64,186.4,,0.001,0.001,106.524,0.059,0.008,0.0107,1791.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-03",4,3.3,252.14,,0.001,0.001,141.182,0.059,0.01,0.013,2374.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-04",5,4.04,365.9,,0.001,0.001,198.464,0.059,0.013,0.0126,3340.689,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-05",7,4.34,193.42,,0.001,0.001,126.983,0.0596,0.01,0.0206,2136.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-06",11,7.57,425.25,,0.001,0.001,259.968,0.0593,0.017,0.0231,4373.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-07",9,5.85,293.22,,0.001,0.001,185.132,0.059,0.013,0.0184,3115.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-08",11,8.77,446.75,,0.001,0.001,278.744,0.0592,0.018,0.0095,4691.727,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-09",5,3.07,65.3,,0,0.001,56.954,0.0594,0.007,0.0178,957.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-10",2,0.47,0,,0,0.001,3.535,0.059,0.002,0.0365,59.531,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-16",5,3.62,214.1,,0.001,0.001,127.926,0.059,0.008,0.0156,2153.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-17",2,1.55,64.8,,0,0.001,42.81,0.0595,0.004,0.015,720.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-21",11,8.94,402.74,,0.001,0.001,262.963,0.0591,0.019,0.0155,4424.277,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-22",4,3.3,252.54,,0.001,0.001,141.438,0.059,0.011,0.0138,2381.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-23",2,1.3,88.42,,0,0.001,50.658,0.059,0.005,0.0215,851.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-24",6,4.29,225.92,,0.001,0.001,142.501,0.0593,0.01,0.022,2397.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-25",6,4.3,344.08,,0.001,0.001,192.576,0.0592,0.014,0.0212,3240.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-26",6,4.29,302.92,,0.001,0.001,175.001,0.059,0.012,0.0208,2945.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-27",6,5.03,250.2,,0.001,0.001,159.679,0.0592,0.011,0.0078,2687.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-28",16,12.61,889.42,,0.003,0.001,512.48,0.0593,0.032,0.0154,8619.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-29",5,3.37,93.4,,0,0.001,74.229,0.0594,0.006,0.019,1248.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-30",4,2.28,65.08,,0,0.001,51.394,0.0593,0.005,0.0293,865.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-01",6,4.53,157.21,,0.001,0.001,114.31,0.059,0.009,0.0223,1924.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-02",6,4.78,150.21,,0.001,0.001,114.331,0.059,0.009,0.0227,1923.551,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-03",7,5.28,136.34,,0.001,0.001,113.804,0.0591,0.008,0.0194,1914.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-04",3,1.56,96.36,,0,0.001,57.388,0.059,0.005,0.0157,966.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-10",8,5.58,159.27,,0.001,0.001,126.148,0.0593,0.011,0.0145,2123.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-11",5,3.28,82.6,,0,0.001,70.462,0.0596,0.006,0.0244,1184.519,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-14",3,2.53,114.57,,0,0.001,76.604,0.0597,0.008,0.0097,1287.324,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-15",3,1.78,70.61,,0,0.001,49.3,0.0593,0.005,0.0103,828.831,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-17",5,2.58,56.29,,0,0.001,50.504,0.0594,0.005,0.0254,849.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-20",5,3.65,209.98,,0.001,0.001,129.765,0.0592,0.012,0.0256,2182.711,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-22",6,4.78,166.04,,0.001,0.001,122.884,0.0592,0.009,0.0218,2067.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-23",6,4.53,132.94,,0.001,0.001,105.314,0.0592,0.008,0.022,1771.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-24",5,4.05,154.3,,0.001,0.001,109.545,0.0592,0.008,0.026,1842.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-26",7,6.28,417.52,,0.001,0.001,246.924,0.0593,0.015,0.008,4156.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-27",8,6.56,420.82,,0.001,0.001,251.189,0.0591,0.015,0.008,4227.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-28",2,1.54,46.02,,0,0.001,35.514,0.0595,0.004,0.0135,597.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-29",5,2.83,80.57,,0,0.001,63.85,0.0594,0.007,0.0284,1073.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-06-30",3,1.88,156.48,,0,0.001,88.024,0.0593,0.007,0.0247,1480.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-01",5,4.05,274.25,,0.001,0.001,160.835,0.059,0.012,0.0128,2706.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-02",4,2.78,192.68,,0.001,0.001,112.404,0.059,0.009,0.0123,1891.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-03",3,1.39,78.84,,0,0.001,48.382,0.0597,0.005,0.0243,813.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-04",4,3.3,283.2,,0.001,0.001,157.055,0.059,0.011,0.0098,2642.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-05",6,5.37,322.07,,0.001,0.001,195.945,0.0593,0.012,0.0087,3295.238,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-06",4,3.65,328.36,,0.001,0.001,179.701,0.059,0.013,0.0093,3023.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-07",4,3.32,307.34,,0.001,0.001,167.118,0.059,0.012,0.0085,2812.472,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-09",4,2.88,261.83,,0.001,0.001,143.342,0.059,0.009,0.0195,2411.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-10",10,8.55,628.72,,0.002,0.001,361.744,0.0591,0.022,0.0151,6089.303,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-11",10,8.63,667.92,,0.002,0.001,379.031,0.059,0.024,0.008,6375.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-12",10,8.58,653.76,,0.002,0.001,371.962,0.059,0.022,0.0148,6261.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-13",9,7.83,614.47,,0.002,0.001,345.352,0.0591,0.021,0.0161,5809.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-16",3,1.8,141.1,,0,0.001,79.55,0.0593,0.008,0.0103,1338.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-21",3,2.3,100.2,,0,0.001,66.83,0.059,0.008,0.0123,1124.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-22",4,3.05,101.4,,0,0.001,75.375,0.0593,0.006,0.0103,1269.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-23",6,4.3,129.55,,0.001,0.001,100.49,0.0593,0.008,0.0218,1691.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-24",6,5.05,130.5,,0.001,0.001,108.165,0.059,0.008,0.008,1821.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-25",6,4.28,152.55,,0.001,0.001,111.381,0.0593,0.008,0.0205,1873.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-26",7,5.55,174.55,,0.001,0.001,134.105,0.0591,0.01,0.0193,2257.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-27",7,4.78,222.86,,0.001,0.001,145.348,0.0591,0.011,0.0186,2447.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-28",4,3.11,186.22,,0.001,0.001,113.121,0.059,0.009,0.0075,1904.161,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-29",8,6.3,467.55,,0.001,0.001,269.635,0.059,0.017,0.0168,4538.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-30",10,8.53,688.15,,0.002,0.001,386.16,0.0591,0.023,0.0148,6497.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-07-31",11,10.03,736.57,,0.002,0.001,423.923,0.059,0.025,0.0087,7134.639,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-01",8,6.3,412.55,,0.001,0.001,243.19,0.059,0.015,0.0168,4092.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-02",7,4.58,119.5,,0,0.001,97.732,0.0596,0.008,0.0193,1642.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-03",8,6.3,164.4,,0.001,0.001,135.47,0.0591,0.009,0.0174,2279.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-04",6,4.28,141.55,,0.001,0.001,105.036,0.0593,0.008,0.0212,1767.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-05",6,4.53,122.29,,0.001,0.001,99.375,0.0595,0.008,0.0217,1671.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-06",5,3.28,82.7,,0,0.001,69.168,0.0592,0.006,0.0246,1163.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-07",6,4.28,121.7,,0,0.001,96.496,0.0593,0.007,0.0215,1623.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-08",5,3.28,99.7,,0,0.001,76.526,0.0592,0.006,0.0242,1289.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-09",6,5.03,243.1,,0.001,0.001,155.038,0.0592,0.013,0.0083,2608.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-10",7,5.36,221.21,,0.001,0.001,150.187,0.059,0.01,0.0137,2526.639,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-11",5,3.3,209.55,,0.001,0.001,123.115,0.0592,0.009,0.023,2071.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-12",5,4.38,369.36,,0.001,0.001,203.563,0.059,0.014,0.0088,3423.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-13",11,10.05,804.5,,0.002,0.001,446.32,0.059,0.027,0.0071,7509.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-14",13,11.28,799.7,,0.002,0.001,458.883,0.0592,0.027,0.0125,7716.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-15",11,9.3,700.7,,0.002,0.001,396.65,0.059,0.023,0.0135,6676.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-16",10,7.33,328.7,,0.001,0.001,215.883,0.059,0.014,0.0155,3633.886,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-17",8,6.7,553.54,,0.002,0.001,307.092,0.0591,0.019,0.013,5166.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-18",13,11.3,404.55,,0.001,0.001,291.49,0.0591,0.018,0.0129,4905.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-19",14,12.28,550.85,,0.002,0.001,363.888,0.0593,0.027,0.0114,6121.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-20",12,10.28,769.7,,0.002,0.001,437.228,0.0592,0.027,0.0141,7354.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-21",13,11.3,597.7,,0.002,0.001,373.18,0.0591,0.022,0.0129,6280.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-22",12,10.32,609.3,,0.002,0.001,368.172,0.059,0.022,0.0135,6197.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-23",9,7.53,525.81,,0.002,0.001,303.915,0.059,0.018,0.0161,5114.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-24",12,9.7,627.05,,0.002,0.001,369.48,0.0591,0.022,0.0142,6217.981,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-25",13,10.55,858.13,,0.002,0.001,477.649,0.0592,0.03,0.0146,8037.301,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-26",9,7.28,524.55,,0.002,0.001,299.961,0.0591,0.019,0.0177,5047.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-27",10,9.05,828.6,,0.002,0.001,447.17,0.0591,0.028,0.0073,7527.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-28",8,4.88,214.75,,0.001,0.001,142.258,0.059,0.011,0.0275,2392.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-29",6,4.28,131,,0.001,0.001,100.978,0.059,0.008,0.0203,1699.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-30",4,2.28,59.15,,0,0.001,48.751,0.059,0.005,0.0273,821.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-08-31",5,3.28,83.85,,0,0.001,69.343,0.0592,0.006,0.024,1167.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-01",5,3.3,113.7,,0,0.001,83.505,0.059,0.007,0.0246,1406.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-02",5,3.3,93.7,,0,0.001,74.18,0.0592,0.006,0.0242,1248.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-03",8,6.3,436.55,,0.001,0.001,252.775,0.0593,0.016,0.0178,4254.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-04",10,8.53,608,,0.002,0.001,348.688,0.0591,0.022,0.0086,5868.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-05",12,11.05,980.8,,0.003,0.001,534.5,0.059,0.033,0.0072,8995.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-06",16,14.28,918.7,,0.003,0.001,542.843,0.0591,0.031,0.0116,9133.253,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-07",12,9.58,271.73,,0.001,0.001,213.387,0.0593,0.014,0.0079,3591.273,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-08",13,9.6,431.59,,0.001,0.001,280.917,0.059,0.019,0.0174,4728.069,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-09",10,8.61,244.56,,0.001,0.001,191.988,0.0592,0.013,0.0082,3230.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-10",8,5.58,130.4,,0.001,0.001,110.883,0.0593,0.008,0.0176,1867.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-11",10,7.58,238.7,,0.001,0.001,179.468,0.0591,0.012,0.016,3020.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-12",8,6.28,304.7,,0.001,0.001,193.883,0.0596,0.012,0.0173,3260.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-13",9,7.61,277.92,,0.001,0.001,195.739,0.0592,0.013,0.0124,3292.679,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-14",11,9.78,520.12,,0.002,0.001,321.928,0.0592,0.021,0.0087,5417.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-15",5,3.92,183.41,,0.001,0.001,120.026,0.059,0.009,0.0228,2021.137,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-16",7,5.36,157.52,,0.001,0.001,122.834,0.0593,0.009,0.0137,2066.653,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-17",11,9.28,426.7,,0.001,0.001,278.753,0.0592,0.017,0.0145,4689.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-18",12,10.6,470.9,,0.002,0.001,310.252,0.0592,0.02,0.0111,5219.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-19",10,9.03,586.4,,0.002,0.001,341.058,0.0591,0.022,0.0074,5740.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-20",12,9.58,465.85,,0.001,0.001,293.96,0.0591,0.018,0.0146,4946.554,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-21",10,8.3,314.89,,0.001,0.001,218.68,0.0591,0.014,0.0152,3678.723,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-22",10,7.67,288.48,,0.001,0.001,199.412,0.0593,0.014,0.0095,3355.467,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-23",8,5.59,233.98,,0.001,0.001,155.831,0.0594,0.011,0.0095,2622.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-24",11,8.83,277.26,,0.001,0.001,207.969,0.0591,0.013,0.0085,3500.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-25",9,6.46,265.52,,0.001,0.0009,177.618,0.0591,0.013,0.007,2989.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-26",10,6.18,150.76,,0.001,0.001,124.469,0.0592,0.01,0.0184,2094.109,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-27",10,7.15,206.77,,0.001,0.001,159.505,0.0592,0.011,0.0162,2684.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-28",9,6.85,230.12,,0.001,0.001,168.554,0.0592,0.012,0.0166,2834.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-29",13,10.15,452.36,,0.001,0.001,295.557,0.0591,0.019,0.0138,4974.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-09-30",17,14.03,521.83,,0.002,0.001,365.847,0.0591,0.022,0.0078,6158.537,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-01",12,9.93,276.6,,0.001,0.001,219.293,0.0593,0.014,0.0132,3692.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-02",13,8.95,290.59,,0.001,0.001,213.718,0.0595,0.014,0.0152,3594.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-03",11,8.58,271.45,,0.001,0.001,202.563,0.0592,0.013,0.0151,3408.709,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-04",11,8.6,315.66,,0.001,0.001,223.917,0.0592,0.014,0.0138,3767.667,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-05",17,14.6,611.36,,0.002,0.001,414.815,0.0591,0.025,0.0115,6981.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-06",10,9.13,304,,0.001,0.001,225.301,0.0591,0.015,0.0072,3790.652,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-07",13,11.9,429.8,,0.002,0.001,308.75,0.0592,0.019,0.0102,5193.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-08",17,14.86,593.78,,0.002,0.001,409.93,0.0593,0.026,0.0085,6893.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-09",12,8.25,306.76,,0.001,0.001,216.695,0.0591,0.015,0.0103,3646.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-10",19,17.35,813.3,,0.003,0.001,533.149,0.0593,0.032,0.0074,8970.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-11",8,4.88,117.6,,0.001,0.001,99.691,0.0596,0.008,0.0195,1676.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-12",14,9.77,344.81,,0.001,0.001,247.661,0.0594,0.018,0.0146,4168.009,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-13",9,5.86,155.5,,0.001,0.001,126.446,0.0592,0.01,0.0184,2127.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-14",8,5.93,175.21,,0.001,0.001,135.766,0.0594,0.01,0.013,2282.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-15",12,9.41,318.68,,0.001,0.001,234.584,0.0592,0.016,0.0143,3947.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-16",10,8,304.69,,0.001,0.001,212.363,0.059,0.015,0.0166,3575.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-17",10,6.76,251.07,,0.001,0.001,177.061,0.0594,0.012,0.0163,2979.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-18",14,11.23,385.02,,0.001,0.001,281.33,0.0595,0.02,0.008,4730.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-19",17,14.61,844.61,,0.003,0.001,513.303,0.059,0.03,0.0078,8639.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-20",14,12.42,470.32,,0.002,0.001,331.234,0.0592,0.021,0.007,5572.682,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-21",11,8.16,320.72,,0.001,0.001,221.301,0.059,0.017,0.0118,3722.932,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-22",13,10.42,492.18,,0.002,0.001,318.532,0.0592,0.022,0.0144,5358.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-23",14,9.7,355.58,,0.001,0.001,252.651,0.0593,0.018,0.0167,4251.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-24",13,10.6,456.36,,0.002,0.001,307.141,0.0591,0.02,0.0143,5169.179,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-25",11,8.58,348.17,,0.001,0.001,238.683,0.0594,0.018,0.0185,4012.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-26",16,11.44,542.76,,0.002,0.001,351.624,0.0592,0.027,0.0204,5917.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-27",12,9.09,483.48,,0.002,0.001,303.24,0.0591,0.02,0.0195,5100.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-28",9,6.01,269.79,,0.001,0.001,178.443,0.0591,0.013,0.0129,3003.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-29",9,6.6,371.4,,0.001,0.001,228.389,0.0591,0.015,0.0178,3842.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-30",8,5.9,259.58,,0.001,0.001,172.254,0.0591,0.013,0.0095,2898.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-10-31",8,5.98,162.65,,0.001,0.001,130.861,0.0591,0.009,0.0096,2203.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-01",12,9.03,432.85,,0.001,0.001,281.676,0.0593,0.02,0.016,4737.361,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-02",11,9.48,473.2,,0.002,0.001,303.29,0.0592,0.019,0.0135,5104.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-03",9,3.47,57.4,,0,0.001,57.206,0.0591,0.007,0.0292,963.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-04",9,7.85,286.26,,0.001,0.001,206.296,0.0591,0.014,0.0082,3471.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-05",7,6.11,364.3,,0.001,0.001,219.142,0.0591,0.016,0.0076,3689.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-06",12,9.58,356.28,,0.001,0.001,249.876,0.0593,0.015,0.0143,4204.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-07",7,4.55,142.46,,0.001,0.001,107.92,0.0591,0.008,0.0197,1815.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-08",12,10.12,343.4,,0.001,0.001,252.892,0.0593,0.017,0.0083,4253.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-09",12,9.23,393.98,,0.001,0.001,264.474,0.0594,0.019,0.021,4448.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-10",18,17.13,598.42,,0.002,0.001,436.395,0.0592,0.026,0.0076,7342.569,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-11",11,8.51,268.85,,0.001,0.001,202.548,0.0592,0.015,0.0086,3408.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-12",14,10.45,310.83,,0.001,0.001,241.94,0.0591,0.017,0.0194,4071.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-13",14,10.48,356.39,,0.001,0.001,262.335,0.0593,0.019,0.0166,4411.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-14",11,8.48,318.56,,0.001,0.001,223.894,0.0593,0.017,0.0163,3766.933,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-15",12,7.95,229.83,,0.001,0.001,179.287,0.0592,0.014,0.0175,3016.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-16",11,9.52,285.22,,0.001,0.001,220.688,0.059,0.014,0.0149,3716.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-17",8,6.3,207.9,,0.001,0.001,154.84,0.059,0.011,0.0175,2606.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-18",18,12.84,385.95,,0.002,0.001,298.568,0.0591,0.02,0.0161,5026.523,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-19",7,5.6,170.57,,0.001,0.001,131.672,0.0593,0.01,0.0174,2214.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-20",9,8.4,275.6,,0.001,0.001,206.9,0.0591,0.014,0.0098,3483.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-21",17,14.1,435.66,,0.002,0.001,334.9,0.0592,0.023,0.0174,5633.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-22",15,13.66,544.45,,0.002,0.001,377.806,0.0592,0.022,0.0073,6357.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-23",20,16.73,863.39,,0.003,0.001,547.279,0.0593,0.032,0.0108,9207.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-24",16,14.08,690.68,,0.002,0.001,448.162,0.059,0.027,0.0099,7542.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-25",7,5.32,219.62,,0.001,0.001,150.928,0.059,0.011,0.0189,2541.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-26",7,4.62,199.04,,0.001,0.001,133.322,0.059,0.01,0.0206,2245.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-27",8,7.1,234.3,,0.001,0.001,175.8,0.0593,0.011,0.0183,2959.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-28",7,4.98,148.52,,0.001,0.001,116.127,0.0593,0.008,0.0104,1952.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-29",7,5.86,212.86,,0.001,0.001,153.968,0.0593,0.01,0.0086,2590.214,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-11-30",7,5.15,193.09,,0.001,0.001,136.007,0.059,0.012,0.0129,2287.483,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-01",12,10.51,460.24,,0.002,0.001,308.716,0.0591,0.021,0.0148,5194.437,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-02",8,5.71,177.53,,0.001,0.001,135.188,0.0593,0.01,0.0091,2274.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-03",6,4.48,171.9,,0.001,0.001,122.01,0.0592,0.009,0.021,2053.922,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-04",5,3.78,115.98,,0,0.001,88.1,0.0592,0.007,0.0104,1482.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-05",6,5.3,169.6,,0.001,0.001,126.06,0.0593,0.009,0.0097,2122.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-06",5,3.78,125.58,,0,0.001,92.5,0.0596,0.007,0.0106,1554.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-07",7,5.66,184.9,,0.001,0.001,136.26,0.0591,0.01,0.0099,2293.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-08",8,6.8,275,,0.001,0.001,186.5,0.0591,0.013,0.0214,3139.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-09",2,0.52,15.75,,0,0.001,11.512,0.059,0,0,193.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-17",7,3.88,82,,0,0.001,72.404,0.0594,0.007,0.0229,1218.124,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-18",7,5.28,211.4,,0.001,0.001,144.398,0.0593,0.01,0.0199,2429.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-21",6,4.15,219.4,,0.001,0.001,136.335,0.0592,0.01,0.0203,2294.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-22",5,3.32,170.92,,0.001,0.001,106.394,0.0592,0.009,0.0244,1789.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-23",4,3.03,81.69,,0,0.001,65.262,0.059,0.006,0.0143,1099.479,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-28",3,1.28,24.5,,0,0.001,23.084,0.0593,0.003,0.0407,387.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-29",7,3.9,145.54,,0.001,0.001,100.412,0.0591,0.009,0.0256,1690.486,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-30",9,7.28,296.5,,0.001,0.001,199.796,0.0592,0.013,0.0183,3361.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"7",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-03",3,2.07,135.38,,0,0.001,79.641,0.0597,0.007,0.0187,1339.633,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-06",11,8.33,464.57,,0.001,0.001,286.775,0.0592,0.02,0.0095,4824.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-07",14,12.43,828.49,,0.002,0.001,483.191,0.0591,0.031,0.0081,8131.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-08",10,7.85,537.26,,0.002,0.001,308.995,0.0591,0.02,0.0165,5199.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-09",6,4.55,290.25,,0.001,0.001,170.43,0.0592,0.012,0.0232,2866.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-10",6,4.3,142.56,,0.001,0.001,105.392,0.0593,0.008,0.0228,1773.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-14",8,4.75,141.5,,0.001,0.001,108.73,0.0598,0.011,0.031,1827.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-15",6,4.28,104.68,,0,0.001,88.322,0.059,0.008,0.0235,1488.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-16",3,1.78,44,,0,0.001,36.982,0.0593,0.004,0.0133,622.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-17",2,1.3,27.8,,0,0.001,24.696,0.06,0.004,0.017,414.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-20",5,3.38,224.36,,0.001,0.001,131.094,0.0592,0.01,0.0226,2207.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-28",4,2.3,63.8,,0,0.001,51.49,0.059,0.005,0.0308,867.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-29",8,4.6,259.06,,0.001,0.001,158.96,0.0593,0.013,0.021,2673.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-30",14,12.35,822.69,,0.002,0.001,480.604,0.0591,0.029,0.0084,8087.017,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-01-31",6,4.18,197.26,,0.001,0.001,127.032,0.0593,0.011,0.024,2137.554,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-01",3,2.12,170.68,,0,0.001,95.376,0.059,0.008,0.0387,1604.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-02",12,9.48,276,,0.001,0.001,215.866,0.0594,0.014,0.0141,3632.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-03",7,5.28,283.28,,0.001,0.001,174.933,0.0593,0.013,0.0133,2941.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-04",6,2.87,121.62,,0,0.001,81.748,0.0592,0.009,0.038,1374.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-05",3,1.78,146.78,,0,0.001,81.102,0.059,0.007,0.0393,1365.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-06",3,1.32,69.28,,0,0.001,43.196,0.059,0.005,0.0347,726.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-07",7,6.05,444.95,,0.001,0.001,254.99,0.0591,0.017,0.0089,4290.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-08",8,6.32,201.28,,0.001,0.001,151.54,0.0593,0.011,0.0181,2550.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-09",16,14.3,432.68,,0.002,0.001,333.038,0.0593,0.021,0.0132,5601.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-10",16,14.67,469.15,,0.002,0.001,352.555,0.0594,0.021,0.0119,5929.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-11",7,5.28,216.5,,0.001,0.001,147.732,0.0593,0.011,0.0196,2485.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-13",17,16.03,838.65,,0.003,0.001,528.739,0.0592,0.031,0.0074,8897.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-14",16,15.05,786.49,,0.003,0.001,496.258,0.0592,0.03,0.0122,8350.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-15",11,9.3,340.98,,0.001,0.001,244.554,0.0593,0.016,0.0145,4114.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-16",9,7.3,195.8,,0.001,0.001,160.018,0.0596,0.011,0.0164,2691.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-17",3,1.82,115.82,,0,0.001,67.504,0.0593,0.006,0.0113,1135.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-19",6,5.09,174.49,,0.001,0.001,127.165,0.059,0.009,0.0118,2140.617,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-21",3,2.35,107.27,,0,0.001,69.81,0.059,0.007,0.0147,1174.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-23",10,8.32,249.2,,0.001,0.001,194.488,0.059,0.013,0.016,3273.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-24",6,4.25,165.44,,0.001,0.001,114.766,0.059,0.012,0.0205,1931.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-25",9,8.38,757.96,,0.002,0.001,409.948,0.059,0.026,0.008,6900.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-26",7,6.27,539.41,,0.001,0.001,293.334,0.059,0.019,0.0087,4935.957,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-27",14,11.56,537.42,,0.002,0.001,350.701,0.0592,0.022,0.0146,5901.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-28",6,3.09,109.06,,0,0.001,78.108,0.059,0.008,0.0273,1315.721,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-02-29",11,9.3,497.98,,0.002,0.001,311.496,0.0593,0.02,0.0152,5238.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-01",12,10.47,790.72,,0.002,0.001,445.366,0.059,0.027,0.0121,7494.553,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-02",9,6.9,483.99,,0.001,0.001,275.062,0.059,0.02,0.0244,4629.159,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-03",13,12.3,866.88,,0.002,0.001,494.962,0.059,0.03,0.0073,8328.594,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-05",5,4.13,297.05,,0.001,0.001,168.35,0.059,0.011,0.0104,2832.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-07",14,11.45,330.6,,0.001,0.001,262.568,0.0594,0.017,0.0136,4416.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-08",15,12.19,410.92,,0.002,0.001,304.003,0.0595,0.02,0.0141,5115.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-09",9,6.76,269.49,,0.001,0.001,185.884,0.0592,0.014,0.0174,3126.953,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-10",6,3.58,123.71,,0,0.001,90.013,0.0595,0.007,0.0198,1513.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-12",8,5.68,447.32,,0.001,0.001,251.34,0.0591,0.018,0.0146,4228.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-13",17,16.8,997.22,,0.003,0.001,606.005,0.0592,0.037,0.0073,10195.879,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-14",15,13.88,788.84,,0.002,0.001,485.28,0.0592,0.029,0.0101,8165.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-15",15,13.8,561.72,,0.002,0.001,386.388,0.0592,0.023,0.0115,6500.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-16",16,13.56,660.8,,0.002,0.001,425.57,0.0591,0.026,0.0119,7158.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-19",3,1.8,121.32,,0,0.001,70.218,0.0593,0.006,0.0123,1180.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-22",10,9.04,285.88,,0.001,0.001,215.748,0.059,0.014,0.0152,3630.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-25",6,4.3,128.04,,0.001,0.001,99.644,0.0595,0.007,0.0207,1676.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-26",8,6.74,483.96,,0.001,0.001,277.209,0.0591,0.018,0.01,4662.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-27",2,1.54,33.28,,0,0.001,29.514,0.059,0.003,0.014,497.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-28",11,9.29,289.8,,0.001,0.001,220.629,0.0595,0.014,0.0143,3710.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-29",12,10.52,341.32,,0.001,0.001,255.196,0.0592,0.016,0.0132,4295.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-05",9,8.12,248.55,,0.001,0.001,189.14,0.0593,0.012,0.0077,3182.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-06",8,6.3,253.95,,0.001,0.001,172.781,0.0591,0.012,0.0169,2908.173,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-11",6,4.8,295.6,,0.001,0.001,175.066,0.059,0.011,0.0087,2944.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-13",4,2.47,183.5,,0.001,0.001,101.782,0.0593,0.008,0.0165,1713.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-14",3,2.54,195.34,,0.001,0.001,108.288,0.059,0.009,0.0113,1822.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-16",3,2.05,46.37,,0,0.001,40.389,0.0593,0.004,0.0117,679.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-19",3,1.29,32.04,,0,0.001,26.437,0.0593,0.004,0.0367,444.825,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-20",5,4.55,258.45,,0.001,0.001,156.306,0.0592,0.011,0.0094,2628.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-21",4,2.79,202.58,,0.001,0.001,114.764,0.059,0.009,0.0098,1931.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-22",15,14.31,1355.77,,0.004,0.001,728.203,0.059,0.054,0.0101,12255.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-24",3,2.29,51.32,,0,0.001,44.953,0.059,0.004,0.0113,756.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-26",2,0.48,0,,0,0.001,3.711,0.059,0.001,0.0535,62.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-02",3,2.62,175.3,,0.001,0.001,101.842,0.0593,0.011,0.0197,1712.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-03",4,3.3,252.14,,0.001,0.001,141.09,0.059,0.01,0.013,2375.552,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-04",4,2.88,260.8,,0.001,0.001,141.072,0.0593,0.01,0.0215,2373.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-05",6,3.09,115.1,,0,0.001,80.216,0.0592,0.008,0.022,1350.124,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-06",3,1.6,97.81,,0,0.001,57.993,0.0593,0.007,0.0137,975.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-07",6,3.09,126.67,,0,0.001,85.412,0.0595,0.007,0.0195,1436.223,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-08",14,12.35,685.25,,0.002,0.001,418.442,0.0591,0.027,0.0091,7041.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-09",8,7.05,441.61,,0.001,0.001,258.259,0.0591,0.016,0.0083,4345.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-10",8,4.58,118.42,,0,0.001,95.746,0.0593,0.009,0.0254,1610.867,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-12",2,1.81,103.62,,0,0.001,62.537,0.059,0.006,0.0115,1053.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-13",12,9.6,377.69,,0.001,0.001,260.318,0.059,0.016,0.0133,4381.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-14",5,4.05,191.27,,0.001,0.001,122.931,0.059,0.009,0.0086,2069.458,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-15",6,5.05,199.76,,0.001,0.001,136.696,0.0593,0.01,0.0073,2299.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-16",6,4.79,315.91,,0.001,0.001,183.351,0.0593,0.012,0.01,3085.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-17",2,1.55,64.8,,0,0.001,42.81,0.059,0.004,0.014,720.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-18",3,2.3,196.2,,0.001,0.001,106.91,0.059,0.008,0.016,1798.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-21",5,4.05,307.6,,0.001,0.001,173.331,0.0594,0.012,0.0128,2916.329,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-22",3,2.14,148.54,,0,0.001,84.96,0.059,0.007,0.0247,1430.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-24",6,4.29,225.92,,0.001,0.001,142.513,0.0593,0.009,0.019,2397.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-25",6,4.3,344.08,,0.001,0.001,192.502,0.0592,0.012,0.0187,3240.459,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-26",5,3.25,248.92,,0.001,0.001,141.294,0.0592,0.01,0.0212,2376.397,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-27",5,3.37,181.54,,0.001,0.001,113.167,0.0592,0.009,0.0146,1903.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-28",16,12.61,872.42,,0.003,0.001,505.424,0.0593,0.031,0.0135,8503.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-29",5,3.37,93.4,,0,0.001,74.546,0.0594,0.006,0.018,1254.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-01",2,0.56,8.23,,0,0.001,8.905,0.06,0.005,0.075,149.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-02",6,4.78,150.21,,0.001,0.001,114.609,0.0592,0.008,0.0202,1929.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-03",7,5.28,136.34,,0.001,0.001,113.804,0.0591,0.009,0.0181,1916.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-10",6,4.28,132.21,,0.001,0.001,101.865,0.059,0.008,0.0202,1714.029,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-14",3,2.53,114.57,,0,0.001,76.516,0.059,0.008,0.0097,1287.859,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-15",3,1.78,70.61,,0,0.001,49.3,0.059,0.005,0.0103,829.199,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-17",2,1.3,27.3,,0,0.001,24.96,0.0595,0.003,0.0145,419.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-20",2,1.87,143.79,,0,0.001,82.048,0.059,0.007,0.01,1382.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-22",6,4.78,166.04,,0.001,0.001,122.971,0.0592,0.009,0.0197,2069.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-23",6,4.53,132.94,,0.001,0.001,105.401,0.059,0.008,0.0197,1774.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-24",5,4.03,154.24,,0.001,0.001,109.514,0.0592,0.008,0.0224,1842.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-26",6,5.13,369.57,,0.001,0.001,213.884,0.059,0.015,0.0085,3599.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-27",6,5.28,392.74,,0.001,0.001,226.206,0.0592,0.014,0.0085,3804.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-28",2,1.55,45.69,,0,0.001,35.427,0.059,0.004,0.0125,596.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-29",2,1.53,52.02,,0,0.001,38.583,0.0595,0.004,0.014,649.242,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-06-30",3,1.88,156.48,,0,0.001,87.736,0.059,0.007,0.025,1476.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-01",4,2.88,219.86,,0.001,0.001,125.093,0.0593,0.009,0.0198,2103.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-02",3,1.63,85.38,,0,0.001,53.547,0.059,0.005,0.0237,900.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-03",4,2.65,209.83,,0.001,0.001,118.589,0.0593,0.009,0.0205,1996.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-04",4,3.3,282.55,,0.001,0.001,157.12,0.059,0.012,0.0098,2642.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-05",4,3.62,245.68,,0.001,0.001,144.132,0.059,0.01,0.008,2426.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-06",5,4.82,432.52,,0.001,0.001,237.378,0.0592,0.017,0.0088,3991.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-07",4,3.32,307.34,,0.001,0.001,167.408,0.0593,0.012,0.0085,2816.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-09",4,2.87,262.01,,0.001,0.001,143.376,0.059,0.01,0.02,2411.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-10",10,8.55,629.3,,0.002,0.001,362.134,0.059,0.021,0.0137,6093.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-11",10,8.63,667.92,,0.002,0.001,379.235,0.0591,0.023,0.008,6382.601,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-12",10,8.58,653.76,,0.002,0.001,372.304,0.0591,0.022,0.0137,6266.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-13",9,7.83,614.47,,0.002,0.001,345.488,0.0592,0.021,0.0149,5811.201,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-15",2,1.32,98.94,,0,0.001,56.2,0.059,0.006,0.013,944.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-16",3,1.8,142.1,,0,0.001,79.55,0.059,0.007,0.0097,1338.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-21",3,2.3,100.2,,0,0.001,66.93,0.059,0.006,0.0097,1125.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-22",4,3.05,101.4,,0,0.001,75.64,0.0593,0.006,0.0103,1272.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-23",6,4.3,129.55,,0.001,0.001,100.705,0.059,0.007,0.0195,1695.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-24",6,5.05,130.5,,0.001,0.001,108.655,0.0593,0.007,0.0075,1826.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-25",6,4.28,152.55,,0.001,0.001,111.481,0.0592,0.008,0.0198,1877.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-26",7,5.55,174.15,,0.001,0.001,134.605,0.0591,0.009,0.0177,2265.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-27",7,4.83,222.77,,0.001,0.001,146.457,0.0591,0.011,0.0177,2464.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-28",6,4.55,231.35,,0.001,0.001,148.255,0.059,0.01,0.0192,2496.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-29",8,6.3,467.55,,0.001,0.001,270.05,0.0593,0.017,0.0159,4543.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-30",10,8.53,688.15,,0.002,0.001,386.183,0.0591,0.023,0.0144,6497.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-07-31",11,10.03,736.57,,0.002,0.001,423.666,0.0591,0.025,0.0085,7130.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-01",8,6.3,412.55,,0.001,0.001,243.29,0.0591,0.015,0.0159,4093.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-02",7,4.56,119.5,,0,0.001,97.636,0.0594,0.007,0.0179,1644.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-03",8,6.26,164.34,,0.001,0.001,135.589,0.0593,0.009,0.016,2281.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-04",6,4.28,141.55,,0.001,0.001,105.351,0.0595,0.008,0.0198,1771.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-05",6,4.53,122.29,,0.001,0.001,99.645,0.0593,0.007,0.0198,1676.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-06",5,3.28,82.55,,0,0.001,69.336,0.0592,0.006,0.022,1167.303,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-07",6,4.28,121.55,,0,0.001,96.796,0.0592,0.007,0.0193,1629.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-08",5,3.3,99.7,,0,0.001,76.95,0.059,0.006,0.0212,1295.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-09",6,5.03,243.1,,0.001,0.001,155.251,0.0593,0.009,0.0062,2611.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-10",7,5.36,220.98,,0.001,0.001,150.354,0.0596,0.01,0.013,2527.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-11",5,3.3,209.55,,0.001,0.001,123.13,0.059,0.009,0.0218,2073.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-12",5,4.38,369.36,,0.001,0.001,203.363,0.059,0.014,0.0086,3421.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-13",11,10.05,803.5,,0.002,0.001,446.33,0.059,0.024,0.0063,7512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-14",13,11.28,799.7,,0.002,0.001,458.783,0.0591,0.024,0.0117,7721.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-15",11,9.3,699.7,,0.002,0.001,396.78,0.059,0.024,0.0132,6675.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-16",10,7.33,327.85,,0.001,0.001,216.388,0.0591,0.014,0.015,3642.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-17",11,9.36,667.29,,0.002,0.001,382.419,0.059,0.023,0.0105,6434.127,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-18",13,11.28,404.55,,0.001,0.001,292.036,0.0592,0.017,0.0118,4913.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-19",14,12.28,550.85,,0.002,0.001,364.401,0.0592,0.021,0.0118,6132.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-20",12,10.28,770.7,,0.002,0.001,437.698,0.059,0.026,0.0127,7365.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-21",13,11.3,598.85,,0.002,0.001,373.695,0.0592,0.022,0.0123,6289.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-22",12,10.32,608.15,,0.002,0.001,368.642,0.0592,0.022,0.0126,6202.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-23",12,9.93,703.19,,0.002,0.001,405.208,0.0591,0.024,0.0103,6818.707,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-24",5,2.93,115.46,,0,0.001,79.71,0.059,0.007,0.0144,1341.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-25",4,2.36,122.57,,0,0.001,76.569,0.059,0.007,0.0168,1288.387,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-26",9,7.28,524.55,,0.002,0.001,300.646,0.0591,0.019,0.0151,5057.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-27",10,9.05,828.6,,0.002,0.001,447.66,0.059,0.028,0.0072,7532.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-28",8,4.88,214.3,,0.001,0.001,142.396,0.0593,0.012,0.0251,2396.669,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-29",6,4.28,131.15,,0.001,0.001,101.406,0.0593,0.007,0.0183,1705.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-30",4,2.28,59.15,,0,0.001,48.964,0.0593,0.004,0.0248,824.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-08-31",5,3.28,83.85,,0,0.001,69.686,0.0596,0.005,0.0216,1172.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-01",5,3.28,113.55,,0,0.001,83.736,0.059,0.007,0.0222,1410.715,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-02",5,3.3,93.7,,0,0.001,74.365,0.0592,0.006,0.0214,1252.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-03",8,6.3,436.55,,0.001,0.001,253.075,0.0593,0.015,0.0159,4259.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-04",9,7.36,499.52,,0.001,0.001,289.847,0.0591,0.018,0.0119,4878.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-05",9,7.88,670.86,,0.002,0.001,368.767,0.059,0.022,0.0071,6205.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-06",14,13.11,809.5,,0.002,0.001,485.136,0.059,0.028,0.0066,8164.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-07",12,9.58,271.56,,0.001,0.001,214.17,0.0592,0.013,0.0077,3602.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-08",13,9.6,430.44,,0.001,0.001,281.434,0.0592,0.018,0.0157,4732.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-09",10,8.61,244.56,,0.001,0.001,192.436,0.0592,0.013,0.008,3239.451,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-10",8,5.58,130.4,,0.001,0.001,111.228,0.0593,0.008,0.0164,1871.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-11",10,7.58,238.7,,0.001,0.001,179.838,0.0592,0.012,0.0147,3025.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-12",8,6.28,304.7,,0.001,0.001,193.998,0.059,0.012,0.0163,3262.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-13",9,7.61,277.53,,0.001,0.001,196,0.0592,0.013,0.0122,3298.178,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-14",9,7.61,305.93,,0.001,0.001,208.456,0.0591,0.014,0.0114,3507.847,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-15",10,7.1,268.9,,0.001,0.001,190.38,0.0591,0.015,0.0239,3203.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-16",7,5.36,157.52,,0.001,0.001,123.057,0.0591,0.009,0.0133,2070.791,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-17",11,9.28,426.7,,0.001,0.001,279.553,0.0592,0.017,0.0133,4702.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-18",14,12.61,619.44,,0.002,0.001,395.155,0.0592,0.024,0.0094,6648.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-19",10,9.03,585.4,,0.002,0.001,342.048,0.0592,0.021,0.0071,5753.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-20",10,8.28,436.7,,0.001,0.001,269.183,0.0594,0.017,0.0137,4528.594,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-21",10,8.3,315.06,,0.001,0.001,219.327,0.0592,0.013,0.0135,3691.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-22",10,7.67,288.48,,0.001,0.001,199.725,0.0592,0.013,0.0085,3361.523,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-23",8,5.59,233.98,,0.001,0.001,156.115,0.0591,0.01,0.0088,2627.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-24",11,8.85,277.9,,0.001,0.001,208.832,0.0594,0.014,0.0085,3512.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-25",7,5.29,198.06,,0.001,0.001,137.848,0.0593,0.01,0.0169,2320.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-26",8,4.86,121.4,,0.001,0.001,99.51,0.0593,0.007,0.0165,1674.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-27",8,5.83,178.58,,0.001,0.001,134.729,0.0594,0.009,0.0155,2267.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-28",9,5.78,159.11,,0.001,0.001,126.357,0.0593,0.009,0.0142,2124.907,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-29",11,8.83,363.93,,0.001,0.001,245.581,0.0591,0.015,0.0134,4132.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-09-30",17,13.86,463.85,,0.002,0.001,340.654,0.0593,0.02,0.0074,5730.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-01",10,8.3,238.72,,0.001,0.001,187.321,0.0591,0.012,0.0134,3153.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-02",13,8.95,290.59,,0.001,0.001,213.952,0.0592,0.014,0.0132,3599.636,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-03",11,8.58,271.25,,0.001,0.001,203.334,0.0594,0.013,0.0136,3419.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-04",11,8.6,315.66,,0.001,0.001,224.362,0.0591,0.014,0.0125,3775.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-05",8,5.17,148.01,,0.001,0.001,116.163,0.0594,0.01,0.0166,1955.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-06",16,13.91,533.44,,0.002,0.001,374.943,0.0592,0.023,0.008,6310.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-07",15,13.2,456.97,,0.002,0.001,333.918,0.0592,0.02,0.0091,5620.083,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-08",13,9.49,363.34,,0.001,0.001,255.417,0.0593,0.017,0.0098,4298.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-09",14,9.24,369.96,,0.001,0.001,253.722,0.0592,0.017,0.0134,4270.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-10",12,9.66,481.08,,0.002,0.001,308.79,0.0592,0.019,0.0098,5194.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-11",8,4.88,117.45,,0.001,0.001,100.006,0.0593,0.007,0.0153,1682.162,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-12",15,9.53,338.77,,0.001,0.001,243.748,0.0594,0.016,0.0129,4100.707,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-13",9,5.86,155.33,,0.001,0.001,126.817,0.0593,0.009,0.0153,2134.541,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-14",8,5.93,175.21,,0.001,0.001,135.829,0.0591,0.009,0.0114,2287.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-15",12,10.29,377.4,,0.001,0.001,270.484,0.0592,0.017,0.0121,4551.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-16",11,9.07,336.3,,0.001,0.001,237.932,0.0595,0.015,0.0126,4002.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-17",9,6.65,219.89,,0.001,0.001,163.822,0.0594,0.01,0.0133,2755.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-18",12,9.76,489.84,,0.002,0.001,310.95,0.0593,0.019,0.0077,5231.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-19",16,13.9,727.42,,0.002,0.001,456.734,0.0591,0.026,0.0071,7690.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-20",14,11.13,432.17,,0.002,0.001,301.199,0.0593,0.019,0.0074,5069.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-21",13,10.98,433.7,,0.002,0.001,300.548,0.0593,0.017,0.011,5058.659,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-22",13,10.72,468.94,,0.002,0.001,312.585,0.0591,0.021,0.0103,5263.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-23",14,9.69,340.72,,0.001,0.001,246.74,0.0591,0.016,0.0135,4153.144,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-24",12,8.84,365.3,,0.001,0.001,250.272,0.059,0.015,0.0123,4214.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-25",14,11.14,429.98,,0.002,0.001,301.754,0.0592,0.017,0.0105,5076.803,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-26",14,9.72,448.65,,0.001,0.001,294.091,0.0593,0.02,0.0127,4949.554,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-27",9,7.44,381.14,,0.001,0.001,241.543,0.0592,0.016,0.0081,4065.133,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-28",7,4.26,179.22,,0.001,0.001,120.95,0.0593,0.009,0.0099,2034.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-29",9,6.6,371.4,,0.001,0.001,228.532,0.0592,0.014,0.0137,3845.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-30",6,3.65,142.08,,0,0.001,98.266,0.0593,0.008,0.0135,1653.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-10-31",8,5.98,162.65,,0.001,0.001,131.561,0.0593,0.01,0.01,2212.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-01",16,13.77,639.01,,0.002,0.001,422.315,0.0591,0.025,0.0106,7109.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-02",12,9.6,473.2,,0.002,0.001,304.602,0.0592,0.018,0.0113,5125.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-03",13,9.72,353.4,,0.001,0.001,254.952,0.0592,0.016,0.012,4291.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-04",8,6.28,219.38,,0.001,0.001,161.038,0.0591,0.01,0.0148,2709.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-05",11,10.13,541.38,,0.002,0.001,338.134,0.0593,0.02,0.0076,5688.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-06",13,9.78,355.38,,0.001,0.001,252.556,0.0591,0.016,0.0118,4250.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-07",7,4.55,142.46,,0.001,0.001,107.995,0.0593,0.008,0.0174,1819.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-08",7,5.28,139.38,,0.001,0.001,114.842,0.0593,0.008,0.0174,1932.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-09",10,7.56,337.79,,0.001,0.001,223.056,0.0591,0.017,0.0158,3752.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-10",13,11.48,440.14,,0.002,0.001,309.582,0.0592,0.02,0.0112,5207.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-11",15,13.36,474.99,,0.002,0.001,343.383,0.0591,0.022,0.0079,5779.633,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-12",17,13.15,419.71,,0.002,0.001,318.949,0.0593,0.02,0.0143,5365.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-13",13,10.58,318.3,,0.001,0.001,248.454,0.0593,0.016,0.0171,4179.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-14",9,6.68,216.95,,0.001,0.001,162.449,0.059,0.01,0.0151,2734.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-15",13,8.14,233.13,,0.001,0.001,183.061,0.0592,0.014,0.0161,3081.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-16",9,8.18,259.84,,0.001,0.001,198.134,0.0594,0.013,0.0128,3331.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-17",10,7.79,241.33,,0.001,0.001,184.996,0.0592,0.012,0.0085,3112.437,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-18",15,12.31,402.41,,0.002,0.001,302.752,0.0591,0.019,0.016,5095.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-19",9,7.53,256.75,,0.001,0.001,189.5,0.0593,0.014,0.0149,3188.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-20",9,8.4,275.6,,0.001,0.001,207.36,0.0592,0.013,0.0092,3488.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-21",12,10.36,324.84,,0.001,0.001,249.056,0.0593,0.017,0.0118,4191.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-22",13,10.54,432.84,,0.002,0.001,297.968,0.0592,0.017,0.0104,5015.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-23",19,15.85,860.06,,0.003,0.001,538.415,0.0592,0.032,0.0105,9056.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-24",18,17.12,814.88,,0.003,0.001,535.847,0.0593,0.032,0.0073,9017.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-25",7,4.98,147.38,,0.001,0.001,115.905,0.059,0.008,0.0104,1950.297,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-26",7,4.6,131.5,,0.001,0.001,104.13,0.0594,0.008,0.0183,1751.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-27",8,7.1,233.4,,0.001,0.001,176.03,0.0591,0.011,0.0158,2963.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-28",9,7.54,241.28,,0.001,0.001,183.169,0.0592,0.012,0.0097,3082.161,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-29",8,7.68,289.68,,0.001,0.001,207.788,0.059,0.013,0.0081,3496.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-11-30",11,8.73,340.95,,0.001,0.001,238.942,0.0591,0.015,0.0094,4019.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-01",10,7.36,331.68,,0.001,0.001,219.701,0.0591,0.017,0.0129,3698.726,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-02",8,6.85,236.27,,0.001,0.001,173.331,0.0591,0.011,0.0083,2917.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-03",7,5.61,242.48,,0.001,0.001,164.861,0.0591,0.011,0.0166,2773.227,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-04",5,3.78,115.8,,0,0.001,88.1,0.0592,0.006,0.0102,1483.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-07",11,8.6,342.46,,0.001,0.001,233.846,0.0593,0.018,0.0155,3933.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-08",12,7.88,249.98,,0.001,0.001,185.75,0.0593,0.014,0.0198,3127.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-09",8,6.39,298.48,,0.001,0.001,192.058,0.0593,0.014,0.0096,3230.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-10",5,3.36,89.86,,0,0.001,72.292,0.059,0.006,0.019,1216.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-15",7,6.03,191.07,,0.001,0.001,143.313,0.0591,0.01,0.0109,2413.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-16",8,6.55,223.01,,0.001,0.001,162.269,0.0593,0.01,0.0149,2730.413,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-17",7,3.88,81,,0,0.001,72.654,0.059,0.006,0.0163,1223.258,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-18",8,6.53,255.85,,0.001,0.001,176.915,0.0594,0.011,0.015,2975.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-21",7,4.65,249.89,,0.001,0.001,153.948,0.0593,0.011,0.0156,2590.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-22",7,5.28,231.68,,0.001,0.001,152.73,0.0594,0.011,0.0159,2569.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-27",7,5.8,203.26,,0.001,0.001,144.406,0.059,0.009,0.0084,2431.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-29",7,3.88,145.4,,0.001,0.001,100.516,0.0596,0.008,0.0177,1691.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-30",7,5.86,233.88,,0.001,0.001,159.24,0.0591,0.011,0.0084,2678.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"8",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-06",3,1.53,35.98,,0,0.001,30.829,0.0593,0.003,0.015,518.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-07",14,12.43,829.09,,0.002,0.001,483.801,0.0591,0.026,0.0071,8141.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-08",8,4.96,320.52,,0.001,0.001,186.722,0.059,0.012,0.0204,3141.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-09",6,4.55,291.25,,0.001,0.001,170.405,0.0592,0.01,0.0195,2867.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-10",6,4.3,143.74,,0.001,0.001,105.516,0.0592,0.007,0.0217,1775.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-14",9,5.85,176.42,,0.001,0.001,134.772,0.0591,0.011,0.024,2266.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-15",6,4.28,104.68,,0,0.001,88.34,0.0593,0.006,0.0203,1488.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-17",2,1.3,27.8,,0,0.001,24.696,0.0595,0.003,0.015,415.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-20",3,1.9,136.5,,0,0.001,77.61,0.059,0.006,0.0297,1305.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-23",4,3.07,84.14,,0,0.001,67.617,0.0593,0.006,0.0105,1138.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-28",4,3.55,224.52,,0.001,0.001,133.922,0.059,0.009,0.0088,2252.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-30",8,6.38,498.58,,0.001,0.001,278.808,0.0593,0.018,0.0138,4691.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-01-31",6,5.32,193.05,,0.001,0.001,138.049,0.0593,0.008,0.0098,2321.637,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-02",11,9.3,277.68,,0.001,0.001,214.18,0.0592,0.012,0.0131,3605.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-03",6,4.95,212.75,,0.001,0.001,141.163,0.059,0.011,0.0103,2376.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-04",3,1.57,91.15,,0,0.001,54.988,0.059,0.006,0.0363,925.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-05",3,1.8,146.96,,0,0.001,81.348,0.059,0.007,0.0347,1368.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-06",3,1.32,69.28,,0,0.001,43.176,0.059,0.004,0.0317,727.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-08",8,6.32,201.4,,0.001,0.001,151.676,0.0593,0.009,0.016,2553.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-10",16,14.67,470.15,,0.002,0.001,352.579,0.0592,0.019,0.0108,5931.183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-11",7,5.28,216.5,,0.001,0.001,147.876,0.0593,0.01,0.0174,2487.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-17",3,1.82,115.82,,0,0.001,67.626,0.059,0.005,0.011,1137.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-21",7,6.29,323.51,,0.001,0.001,203.369,0.0591,0.012,0.009,3422.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-23",10,8.32,252.2,,0.001,0.001,194.384,0.0593,0.012,0.0141,3269.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-24",5,4.8,148.75,,0.001,0.001,113.515,0.0594,0.007,0.008,1909.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-25",6,5.63,507.21,,0.001,0.001,273.161,0.059,0.016,0.007,4598.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-26",7,6.28,540.76,,0.001,0.001,293.204,0.059,0.017,0.008,4934.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-27",14,11.58,538.32,,0.002,0.001,351.37,0.0593,0.019,0.0138,5910.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-28",6,2.67,69.52,,0,0.001,56.348,0.0592,0.007,0.0295,948.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-02-29",11,9.3,497.98,,0.002,0.001,311.956,0.0591,0.017,0.0135,5249.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-01",12,10.28,689.16,,0.002,0.001,399.346,0.0592,0.023,0.0108,6720.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-02",7,6.38,480.55,,0.001,0.001,269.412,0.059,0.015,0.0071,4533.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-05",6,5.38,345.84,,0.001,0.001,202.428,0.059,0.012,0.009,3405.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-07",14,11.4,331.91,,0.001,0.001,261.125,0.0592,0.015,0.0122,4395.153,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-08",12,10.29,274.92,,0.001,0.001,225.353,0.0593,0.013,0.0126,3793.488,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-09",13,10.59,395.76,,0.001,0.001,279.319,0.0592,0.017,0.013,4700.671,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-10",3,1.8,139.56,,0,0.001,78.12,0.059,0.006,0.0313,1314.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-12",8,5.68,447.52,,0.001,0.001,251.16,0.0593,0.015,0.013,4226.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-13",4,3.88,337.16,,0.001,0.001,184.802,0.059,0.012,0.0075,3109.699,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-14",15,13.88,790.84,,0.002,0.001,485.132,0.0591,0.024,0.009,8163.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-15",15,13.8,562.72,,0.002,0.001,386.032,0.0591,0.019,0.0105,6497.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-16",13,11.54,617.1,,0.002,0.001,385.22,0.0593,0.02,0.0116,6480.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-24",3,1.79,76.98,,0,0.001,50.981,0.0593,0.005,0.032,857.001,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-06",8,5.15,186.77,,0.001,0.001,131.631,0.0591,0.009,0.0166,2215.231,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-13",4,2.47,183.5,,0.001,0.001,101.752,0.0593,0.006,0.0158,1711.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-14",3,2.55,194.83,,0.001,0.001,108.007,0.0593,0.009,0.0123,1816.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-16",3,2.05,46.37,,0,0.001,40.184,0.059,0.004,0.0113,677.077,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-21",17,15.3,1513.95,,0.004,0.001,801.768,0.059,0.051,0.0119,13493.737,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-24",7,5,232.35,,0.001,0.001,149.632,0.0593,0.01,0.0101,2518.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-25",4,3.3,95.08,,0,0.001,73.888,0.059,0.005,0.0113,1243.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-04-30",2,1.28,31.86,,0,0.001,26.241,0.059,0.003,0.013,441.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-01",4,2.5,213.93,,0.001,0.001,118.1,0.059,0.008,0.012,1986.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-02",3,2.64,186.4,,0.001,0.001,106.624,0.059,0.007,0.0087,1794.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-03",4,3.3,253.14,,0.001,0.001,141.282,0.059,0.009,0.0108,2377.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-04",4,2.89,261.15,,0.001,0.001,141.898,0.0593,0.008,0.017,2386.523,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-05",3,1.3,29.08,,0,0.001,25.133,0.059,0.003,0.03,423.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-07",6,3.09,127.47,,0,0.001,85.506,0.0592,0.006,0.0192,1438.624,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-08",7,5.89,353.57,,0.001,0.001,210.015,0.059,0.012,0.0121,3534.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-09",8,7.05,442.61,,0.001,0.001,258.301,0.0593,0.013,0.007,4346.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-10",8,4.58,118.42,,0,0.001,95.672,0.0593,0.008,0.0234,1610.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-13",3,2.28,155.56,,0,0.001,89.092,0.059,0.007,0.0093,1500.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-14",5,4.05,192.27,,0.001,0.001,123.294,0.0596,0.008,0.0074,2072.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-15",5,3.87,105.3,,0,0.001,83.912,0.0594,0.006,0.0078,1411.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-16",5,3.62,215.3,,0.001,0.001,128.228,0.0594,0.008,0.0158,2156.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-17",3,2.02,64.8,,0,0.001,46.521,0.059,0.006,0.0263,782.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-24",3,1.89,80.72,,0,0.001,54.637,0.0593,0.004,0.0077,919.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-25",6,4.3,344.08,,0.001,0.001,192.472,0.0592,0.01,0.0163,3239.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-26",2,0.84,22.8,,0,0.001,18.12,0.059,0.003,0.04,304.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-27",6,5.03,251.2,,0.001,0.001,159.879,0.059,0.009,0.007,2691.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-28",16,12.61,875.42,,0.003,0.001,506.324,0.0593,0.024,0.0104,8516.273,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-29",7,5.55,239.06,,0.001,0.001,158.937,0.0594,0.009,0.0086,2673.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-30",4,2.28,65.08,,0,0.001,51.535,0.0593,0.004,0.0215,867.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-05-31",8,6.78,203.68,,0.001,0.001,158.972,0.0593,0.01,0.0076,2675.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-01",6,4.53,157.21,,0.001,0.001,114.476,0.0592,0.007,0.0162,1927.409,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-02",6,4.78,150.21,,0.001,0.001,114.683,0.0595,0.007,0.0167,1928.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-03",7,5.28,136.34,,0.001,0.001,113.991,0.0593,0.007,0.0151,1918.161,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-04",3,1.56,96.54,,0,0.001,57.506,0.059,0.004,0.0127,967.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-08",4,3.3,288.48,,0.001,0.001,159.742,0.059,0.009,0.0105,2687.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-09",2,1.28,36.88,,0,0.001,28.69,0.059,0.003,0.0175,482.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-10",8,5.58,159.27,,0.001,0.001,126.681,0.0593,0.009,0.0099,2131.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-11",5,3.28,83.73,,0,0.001,70.066,0.0594,0.005,0.0176,1180.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-13",3,1.55,57.64,,0,0.001,41.19,0.059,0.003,0.0117,693.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-14",6,3.83,146.57,,0.001,0.001,103.861,0.059,0.007,0.0075,1747.973,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-15",3,1.78,70.61,,0,0.001,49.363,0.059,0.004,0.009,830.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-16",2,1.53,81.81,,0,0.001,51.345,0.059,0.004,0.011,864.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-17",5,2.58,56.42,,0,0.001,50.543,0.0594,0.004,0.0182,851.069,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-19",3,1.78,68.5,,0,0.001,48.41,0.059,0.004,0.0123,815.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-20",7,5.06,288.89,,0.001,0.001,179.299,0.0591,0.011,0.0167,3018.689,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-22",6,4.76,166.31,,0.001,0.001,122.817,0.059,0.007,0.016,2067.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-23",6,4.53,132.94,,0.001,0.001,105.401,0.059,0.007,0.016,1774.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-24",5,4.03,155.24,,0.001,0.001,109.575,0.0592,0.006,0.0178,1843.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-26",7,6.28,418.52,,0.001,0.001,247.124,0.059,0.013,0.0066,4160.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-27",8,6.58,422.32,,0.001,0.001,251.765,0.0591,0.012,0.0063,4235.363,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-28",5,4.28,224.12,,0.001,0.001,142.17,0.059,0.008,0.0088,2393.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-29",5,2.83,81.2,,0,0.001,64.003,0.059,0.005,0.0194,1076.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-06-30",4,3.05,271.5,,0.001,0.001,150.165,0.059,0.009,0.0098,2526.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-01",7,4.18,256.56,,0.001,0.001,154.244,0.0591,0.01,0.0187,2595.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-02",5,2.91,123.66,,0,0.001,83.525,0.0592,0.006,0.0132,1405.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-03",4,2.55,183.28,,0.001,0.001,105.66,0.059,0.006,0.0093,1778.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-04",9,6.85,376.45,,0.001,0.001,234.82,0.0592,0.012,0.0074,3951.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-05",8,7.3,419.25,,0.001,0.001,258.18,0.0591,0.013,0.0066,4342.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-06",5,4.82,433.52,,0.001,0.001,237.168,0.059,0.012,0.0064,3990.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-07",7,5.37,375.64,,0.001,0.001,217.726,0.0593,0.013,0.0087,3662.981,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-08",2,1.3,69.3,,0,0.001,43.02,0.059,0.003,0.0155,723.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-09",7,4.18,292.38,,0.001,0.001,169.429,0.059,0.01,0.0177,2852.541,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-10",10,8.57,630.51,,0.002,0.001,362.137,0.059,0.018,0.0109,6093.446,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-11",12,10.55,744.6,,0.002,0.001,431.615,0.0592,0.022,0.007,7263.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-12",10,8.58,654.76,,0.002,0.001,372.106,0.059,0.018,0.0107,6263.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-13",9,7.83,613.79,,0.002,0.001,345.137,0.0591,0.017,0.0117,5808.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-15",2,1.32,98.27,,0,0.001,55.603,0.059,0.005,0.0095,936.019,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-16",3,1.8,142.1,,0,0.001,79.615,0.059,0.005,0.0077,1339.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-18",5,2.83,136.4,,0,0.001,87.711,0.059,0.006,0.0098,1476.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-21",3,2.3,101.2,,0,0.001,66.84,0.059,0.005,0.0077,1125.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-22",4,3.05,101.4,,0,0.001,75.64,0.0593,0.005,0.0083,1272.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-23",9,5.85,166.55,,0.001,0.001,132.66,0.0594,0.009,0.0133,2230.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-24",6,5.03,130.5,,0.001,0.001,108.211,0.0593,0.007,0.0068,1821.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-25",6,4.3,152.7,,0.001,0.001,111.75,0.059,0.007,0.0148,1880.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-26",7,5.55,175.55,,0.001,0.001,134.59,0.0593,0.008,0.0136,2262.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-27",7,4.85,223.2,,0.001,0.001,146.845,0.0591,0.008,0.0136,2471.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-28",8,6.28,315.55,,0.001,0.001,203.376,0.0591,0.011,0.0124,3422.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-29",8,6.3,468.55,,0.001,0.001,269.835,0.0591,0.013,0.012,4539.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-30",10,8.53,688.15,,0.002,0.001,386.113,0.0591,0.019,0.0109,6499.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-07-31",11,10.03,738.57,,0.002,0.001,424.043,0.059,0.021,0.007,7135.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-01",8,6.3,412.55,,0.001,0.001,243.405,0.0591,0.012,0.0125,4095.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-02",7,4.58,119.5,,0,0.001,97.777,0.0593,0.006,0.0147,1645.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-03",8,6.28,164.4,,0.001,0.001,135.631,0.0594,0.007,0.0129,2281.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-04",6,4.28,141.55,,0.001,0.001,105.351,0.0597,0.006,0.0153,1771.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-05",6,4.53,122.29,,0.001,0.001,99.498,0.0593,0.006,0.0158,1674.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-06",5,3.28,83.55,,0,0.001,69.251,0.0592,0.005,0.018,1166.062,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-07",6,4.28,121.7,,0,0.001,96.796,0.0593,0.006,0.0158,1627.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-08",5,3.28,99.85,,0,0.001,76.841,0.0594,0.005,0.0178,1292.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-09",6,5.03,243.1,,0.001,0.001,155.148,0.0592,0.009,0.0063,2610.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-10",9,7.53,331.8,,0.001,0.001,219.041,0.0594,0.012,0.0077,3684.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-11",5,3.3,209.55,,0.001,0.001,123.315,0.059,0.007,0.017,2074.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-12",7,5.8,452.85,,0.001,0.001,253.28,0.059,0.013,0.0139,4261.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-13",11,10.05,804.5,,0.002,0.001,446.42,0.059,0.021,0.0056,7511.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-14",13,11.28,800.7,,0.002,0.001,458.898,0.0591,0.022,0.0096,7721.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-15",11,9.3,700.7,,0.002,0.001,396.95,0.0591,0.019,0.0102,6679.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-16",10,7.31,329.19,,0.001,0.001,216.043,0.0592,0.012,0.0117,3635.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-17",12,10.53,715.2,,0.002,0.001,414.668,0.059,0.02,0.0068,6975.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-18",13,11.28,405.55,,0.001,0.001,291.666,0.0593,0.014,0.0094,4909.194,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-19",14,12.28,552.85,,0.002,0.001,364.343,0.0592,0.018,0.0097,6129.921,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-20",12,10.28,773.85,,0.002,0.001,437.143,0.059,0.022,0.0103,7357.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-21",13,11.28,599.7,,0.002,0.001,373.328,0.0591,0.018,0.0098,6283.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-22",12,10.32,611.3,,0.002,0.001,368.957,0.0591,0.019,0.0102,6208.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-23",13,11.1,797.76,,0.002,0.001,458.052,0.059,0.022,0.0068,7709.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-24",13,10.85,688.89,,0.002,0.001,406.93,0.0592,0.02,0.0098,6844.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-25",13,10.56,839.5,,0.002,0.001,466.225,0.059,0.023,0.0099,7843.857,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-26",9,7.28,524.55,,0.002,0.001,300.476,0.059,0.015,0.0114,5053.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-27",10,9.05,829.6,,0.002,0.001,447.36,0.059,0.023,0.006,7525.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-28",12,7.67,340.08,,0.001,0.001,225.456,0.0593,0.013,0.0125,3793.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-29",6,4.28,132,,0.001,0.001,101.291,0.0595,0.006,0.0145,1703.519,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-30",4,2.28,59.15,,0,0.001,48.966,0.0593,0.004,0.0195,823.447,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-08-31",5,3.28,83.85,,0,0.001,69.556,0.0594,0.005,0.017,1170.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-01",5,3.28,113.55,,0,0.001,83.766,0.0596,0.005,0.0172,1407.991,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-02",5,3.3,93.7,,0,0.001,74.28,0.0594,0.005,0.017,1250.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-03",8,6.3,436.55,,0.001,0.001,253.19,0.0595,0.013,0.0129,4258.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-04",9,7.36,499.52,,0.001,0.001,289.57,0.0592,0.015,0.009,4871.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-05",12,11.05,972,,0.003,0.001,530.58,0.059,0.026,0.0058,8929.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-06",14,13.13,811,,0.002,0.001,485.688,0.0591,0.023,0.0056,8173.931,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-07",12,9.58,274.73,,0.001,0.001,214.052,0.0594,0.011,0.0065,3598.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-08",13,9.6,430.44,,0.001,0.001,280.819,0.0593,0.015,0.0122,4724.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-09",14,11.83,430.57,,0.002,0.001,303.572,0.059,0.016,0.0061,5108.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-10",11,7.38,204.64,,0.001,0.001,160.807,0.0593,0.01,0.0097,2707.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-11",12,9.17,336.32,,0.001,0.001,236.418,0.0591,0.012,0.0074,3979.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-12",8,6.28,304.7,,0.001,0.001,193.683,0.059,0.01,0.0128,3257.647,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-13",10,8.78,389.72,,0.001,0.001,255.184,0.0591,0.014,0.007,4294.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-14",9,7.18,260.62,,0.001,0.001,183.883,0.0593,0.011,0.0087,3093.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-15",10,8.28,341.7,,0.001,0.001,233.683,0.0592,0.012,0.011,3935.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-16",12,10.28,637,,0.002,0.001,378.148,0.0592,0.018,0.0097,6363.657,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-17",13,10.85,544.2,,0.002,0.001,344.892,0.0592,0.017,0.0068,5802.267,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-18",15,13.78,732.92,,0.002,0.001,455.14,0.0591,0.023,0.0065,7658.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-19",10,9.05,586.6,,0.002,0.001,341.684,0.059,0.018,0.006,5750.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-20",12,9.6,465.89,,0.001,0.001,294.493,0.0592,0.015,0.0098,4957.477,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-21",13,9.6,348.46,,0.001,0.001,245.977,0.0593,0.014,0.0118,4138.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-22",10,7.67,289.26,,0.001,0.001,199.618,0.0591,0.01,0.0068,3359.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-23",8,5.59,233.98,,0.001,0.001,156.132,0.0593,0.009,0.0073,2628.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-24",11,8.85,277.9,,0.001,0.001,208.953,0.0594,0.013,0.0077,3515.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-25",9,6.47,265.52,,0.001,0.001,178.212,0.0592,0.011,0.0059,2999.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-26",10,6.16,150.55,,0.001,0.001,124.504,0.0592,0.007,0.0121,2095.629,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-27",10,7.15,206.77,,0.001,0.001,159.731,0.0593,0.009,0.011,2687.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-28",11,8.13,265.02,,0.001,0.001,195.189,0.0592,0.011,0.011,3286.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-29",13,10.13,452.16,,0.001,0.001,296.004,0.0593,0.015,0.0099,4980.333,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-09-30",17,13.9,465.89,,0.002,0.001,341.232,0.0592,0.017,0.0063,5739.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-01",13,10.08,346.62,,0.001,0.001,250.698,0.0592,0.013,0.01,4220.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-02",13,7.7,193.62,,0.001,0.001,159.579,0.0592,0.01,0.0104,2684.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-03",10,6.93,201.39,,0.001,0.001,156.123,0.0593,0.009,0.0109,2627.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-04",12,8.48,293.24,,0.001,0.001,212.509,0.0592,0.012,0.0099,3576.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-05",19,15.94,641.46,,0.002,0.001,441.811,0.0593,0.022,0.0084,7431.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-06",18,14.85,687.51,,0.002,0.001,450.253,0.0593,0.023,0.0092,7572.634,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-07",18,16.12,658.7,,0.002,0.001,451.23,0.0591,0.022,0.0079,7592.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-08",16,12.88,498.19,,0.002,0.001,347.7,0.0593,0.017,0.0064,5851.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-09",15,11.24,488.76,,0.002,0.001,326.09,0.0591,0.017,0.0091,5486.587,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-10",18,16.55,785.91,,0.003,0.001,514.293,0.0592,0.026,0.0062,8651.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-11",10,6.2,146.13,,0.001,0.001,124.899,0.0591,0.008,0.012,2103.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-12",14,9.77,345.81,,0.001,0.001,248.207,0.0592,0.014,0.0097,4177.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-13",12,7.67,213.08,,0.001,0.001,170.349,0.0594,0.01,0.0105,2864.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-14",9,7.09,235.97,,0.001,0.001,174.023,0.0591,0.009,0.0074,2928.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-15",10,7.7,263.81,,0.001,0.001,193.392,0.059,0.011,0.0105,3254.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-16",11,9.07,337.3,,0.001,0.001,237.859,0.0592,0.012,0.0105,4001.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-17",9,6.54,210.27,,0.001,0.001,157.552,0.0592,0.009,0.0117,2651.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-18",16,13.39,552.39,,0.002,0.001,376.209,0.0593,0.02,0.006,6328.529,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-19",15,12.94,724.96,,0.002,0.001,444.673,0.0592,0.023,0.0065,7482.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-20",18,15.37,567.43,,0.002,0.001,403.805,0.0593,0.02,0.0061,6793.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-21",13,10.35,394.71,,0.001,0.001,276.669,0.0592,0.015,0.0079,4656.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-22",13,10.46,492.97,,0.002,0.001,319.782,0.0592,0.017,0.0093,5380.363,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-23",13,8.37,290.74,,0.001,0.001,211.945,0.0593,0.012,0.0106,3566.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-24",12,9.62,476.5,,0.002,0.001,306.063,0.059,0.016,0.0095,5153.009,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-25",13,10.23,403.67,,0.001,0.001,279.75,0.0592,0.015,0.0093,4707.783,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-26",14,8.72,393.92,,0.001,0.001,259.448,0.0594,0.015,0.0133,4363.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-27",7,4.69,283.7,,0.001,0.001,170.476,0.059,0.011,0.0139,2869.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-28",11,7.93,331.1,,0.001,0.001,225.89,0.0594,0.012,0.0106,3798.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-29",9,4.49,188.13,,0.001,0.001,127.119,0.059,0.008,0.0114,2139.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-30",10,7.57,319.76,,0.001,0.001,215.661,0.0593,0.012,0.0107,3628.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-10-31",10,7.65,230.55,,0.001,0.001,177.706,0.0591,0.01,0.0113,2990.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-01",12,10.04,431.29,,0.001,0.001,293.3,0.0593,0.017,0.0084,4934.303,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-02",9,6.74,381.5,,0.001,0.001,234.848,0.0592,0.012,0.0071,3950.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-03",10,7.79,294.04,,0.001,0.001,208.259,0.0594,0.012,0.0078,3503.737,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-04",11,9.28,326.38,,0.001,0.001,237.814,0.0592,0.013,0.0101,4002.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-05",12,9.66,497.61,,0.002,0.001,313.321,0.0591,0.016,0.0088,5270.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-06",5,4.3,159.55,,0.001,0.001,111.875,0.059,0.007,0.0096,1882.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-07",7,4.55,142.46,,0.001,0.001,108.128,0.0591,0.007,0.0146,1819.397,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-08",7,5.28,140.48,,0.001,0.001,114.934,0.0596,0.007,0.013,1932.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-09",14,11.66,472.07,,0.002,0.001,323.748,0.0592,0.018,0.0103,5445.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-10",8,6.38,250.86,,0.001,0.001,174.798,0.0591,0.01,0.0113,2940.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-11",14,13.16,474.79,,0.002,0.001,342.401,0.0591,0.019,0.0069,5762.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-12",12,8.81,270.23,,0.001,0.001,207.952,0.0592,0.012,0.0148,3498.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-13",11,7.26,206.52,,0.001,0.001,162.994,0.0595,0.012,0.0172,2740.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-14",7,4.33,108.73,,0,0.001,91.02,0.0591,0.006,0.0139,1532.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-15",13,9.21,290.3,,0.001,0.001,219.444,0.0592,0.013,0.0133,3695.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-16",9,8.18,259.66,,0.001,0.001,198.18,0.0592,0.011,0.0096,3333.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-17",10,7.79,241.33,,0.001,0.001,184.753,0.0591,0.01,0.0072,3110.768,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-18",8,7.3,234.15,,0.001,0.001,178.174,0.0593,0.009,0.008,2996.003,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-19",7,5.6,170.4,,0.001,0.001,131.636,0.0591,0.008,0.0121,2216.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-20",12,11.03,360.83,,0.001,0.001,271.37,0.0593,0.016,0.0105,4565.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-21",12,10.46,318.74,,0.001,0.001,245.85,0.0591,0.014,0.0108,4136.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-22",13,10.54,435.84,,0.002,0.001,297.814,0.0591,0.015,0.0085,5011.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-23",14,12.87,750.7,,0.002,0.001,459.125,0.0591,0.022,0.0092,7724.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-24",18,17.12,816.88,,0.003,0.001,536.332,0.0592,0.026,0.0061,9026.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-25",7,4.98,148.38,,0.001,0.001,115.87,0.059,0.007,0.0084,1949.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-26",5,2.93,78.83,,0,0.001,63.807,0.0594,0.005,0.011,1073.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-27",8,7.1,234.4,,0.001,0.001,176.12,0.0591,0.01,0.0125,2963.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-28",9,7.54,242.71,,0.001,0.001,183.369,0.0591,0.01,0.0079,3085.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-29",8,7.68,289.68,,0.001,0.001,207.82,0.0591,0.011,0.0068,3497.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-11-30",11,8.71,340.93,,0.001,0.001,238.79,0.0594,0.013,0.008,4015.257,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-01",11,9.35,419.63,,0.001,0.001,279.532,0.0592,0.017,0.0098,4702.393,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-02",8,6.86,236.68,,0.001,0.001,173.46,0.0591,0.009,0.007,2918.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-03",7,5.61,243.48,,0.001,0.001,164.843,0.059,0.01,0.0127,2775.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-04",5,3.78,115.98,,0,0.001,88.258,0.0592,0.006,0.009,1485.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-07",9,7.19,218.22,,0.001,0.001,165.846,0.0592,0.011,0.0086,2789.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-08",7,5.3,192.5,,0.001,0.001,136.58,0.0594,0.008,0.0139,2296.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-09",6,5.11,266.61,,0.001,0.001,164.729,0.0593,0.009,0.0072,2770.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-10",5,3.36,89.86,,0,0.001,72.292,0.0594,0.005,0.0148,1215.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-11",12,8.58,327.1,,0.001,0.001,227.692,0.0592,0.014,0.0152,3832.354,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-17",7,3.88,82.1,,0,0.001,72.526,0.0594,0.005,0.0153,1219.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-18",6,4.61,169.71,,0.001,0.001,120.403,0.0592,0.007,0.0115,2025.972,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-21",6,5.1,267.7,,0.001,0.001,166.304,0.0592,0.01,0.0075,2797.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-22",7,5.3,233.74,,0.001,0.001,152.668,0.059,0.009,0.0123,2570.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-25",6,5.05,128.1,,0.001,0.001,106.101,0.0593,0.007,0.0077,1785.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-29",7,3.92,146.6,,0.001,0.001,101.006,0.0594,0.007,0.0169,1698.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-30",7,5.86,240.56,,0.001,0.001,161.226,0.0593,0.01,0.0081,2713.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cabrillo Power I Encina Power Station",302,"9",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-05",1,1,0,,0,0.001,6.4,0.059,0.004,0.073,107.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-06",24,24,890,,0.005,0.001,937.2,0.0591,0.07,0.012,15772.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-07",24,24,1551,,0.006,0.001,1215.9,0.059,0.068,0.0067,20460.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-08",24,24,708,,0.004,0.001,700.7,0.0592,0.045,0.0085,11788.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-09",24,24,737,,0.004,0.001,782.8,0.059,0.051,0.008,13176.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-10",24,24,575,,0.003,0.001,612.2,0.0592,0.041,0.0082,10299.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-11",24,24,601,,0.003,0.001,614.4,0.059,0.042,0.008,10340.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-12",13,13,199,,0.001,0.001,295.9,0.0591,0.024,0.0115,4980,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-13",24,24,601,,0.003,0.001,618.6,0.0591,0.041,0.008,10411.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-14",1,1,19,,0,0.001,11.7,0.059,0.001,0.012,197.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-15",2,2,0,,0,0.001,19.1,0.059,0.008,0.0555,321.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-16",24,24,488,,0.003,0.001,597.2,0.0593,0.059,0.0124,10047.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-17",9,9,213,,0.001,0.001,208,0.059,0.018,0.0106,3500.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-20",1,1,0,,0,0.001,8.8,0.059,0.005,0.065,148.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-21",24,24,417,,0.003,0.001,578.6,0.0593,0.06,0.0148,9733.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-22",24,24,583,,0.003,0.001,628.3,0.0593,0.041,0.0078,10570.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-23",24,24,535,,0.003,0.001,592.3,0.0592,0.041,0.0084,9967.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-24",7,7,157,,0.001,0.001,156.6,0.0591,0.011,0.0093,2635.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-30",1,1,0,,0,0.001,1.9,0.06,0,0.001,31.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-01-31",24,24,1582,,0.006,0.001,1184,0.0591,0.119,0.0186,19925.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-01",24,24,2950,,0.009,0.001,1827.5,0.059,0.126,0.008,30752.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-02",7,7,38,,0.001,0.001,104.2,0.0591,0.015,0.02,1753.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-03",24,24,589,,0.003,0.001,641.5,0.0592,0.04,0.0073,10794.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-04",2,2,42,,0,0.001,33.4,0.059,0.003,0.0105,561.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-09",17,17,202,,0.002,0.001,365.6,0.0586,0.041,0.0159,6153.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-10",18,18,461,,0.002,0.001,457,0.0592,0.028,0.0078,7691.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-24",21,21,287,,0.002,0.001,452.2,0.0595,0.037,0.014,7609.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-25",20,20,598,,0.003,0.001,576.4,0.0592,0.031,0.007,9698,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-28",9,9,4,,0.001,0.001,120.5,0.059,0.024,0.0253,2028,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-02-29",24,24,589,,0.003,0.001,647.3,0.0592,0.038,0.007,10892.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-01",24,24,608,,0.003,0.001,639.4,0.0591,0.038,0.007,10757.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-02",24,24,616,,0.003,0.001,650.2,0.0591,0.038,0.007,10942.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-03",24,24,626,,0.003,0.001,660.1,0.0592,0.053,0.0096,11106.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-04",24,24,631,,0.003,0.001,650.8,0.0591,0.055,0.01,10953.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-05",24,24,634,,0.003,0.001,652.2,0.0593,0.044,0.008,10971.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-06",24,24,619,,0.003,0.001,641.2,0.0592,0.043,0.008,10789.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-07",24,24,613,,0.003,0.001,637.4,0.0591,0.04,0.0075,10728.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-08",24,24,605,,0.003,0.001,638.2,0.0591,0.038,0.0071,10742.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-09",1,1,21,,0,0.001,14.5,0.06,0.001,0.009,243.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-11",2,2,0,,0,0.001,18,0.0605,0.045,0.2065,301.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-08",4,4,0,,0,0.001,25.3,0.058,0.005,0.0233,425.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-17",20,20,276,,0.002,0.001,492.4,0.0592,0.057,0.0187,8286.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-18",24,24,600,,0.003,0.001,622.4,0.0593,0.037,0.0071,10469.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-19",24,24,600,,0.003,0.001,629.2,0.0591,0.038,0.0073,10587.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-20",10,10,243,,0.001,0.001,239.6,0.0592,0.016,0.008,4031.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-29",10,10,32,,0.001,0.001,175.9,0.0594,0.04,0.0287,2957.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-04-30",24,24,1700,,0.006,0.001,1230.5,0.0592,0.107,0.0075,20701.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-01",9,9,213,,0.001,0.001,218.8,0.0592,0.012,0.0071,3680,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-08",8,8,5,,0.001,0.001,117.2,0.0591,0.037,0.0371,1974.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-09",24,24,643,,0.003,0.001,678.2,0.0593,0.036,0.0064,11408.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-10",7,7,173,,0.001,0.001,177.7,0.059,0.01,0.0064,2989,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-24",5,5,0,,0,0.001,48.3,0.0596,0.012,0.0252,812.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-25",24,24,2642,,0.009,0.001,1834.6,0.0591,0.149,0.0103,30870.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-26",24,24,2939,,0.01,0.001,2021.3,0.059,0.106,0.0061,34012,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-27",24,24,2222,,0.008,0.001,1487.6,0.0591,0.068,0.0057,25032.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-28",24,24,2004,,0.007,0.001,1363.2,0.0591,0.083,0.0067,22940.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-29",24,24,1663,,0.006,0.001,1195.7,0.0591,0.061,0.006,20121.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-30",8,8,184,,0.001,0.001,181.2,0.059,0.01,0.0073,3048.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-01",20,20,653,,0.004,0.001,698.8,0.0591,0.06,0.0166,11762.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-02",20,20,1209,,0.005,0.001,954.6,0.0593,0.048,0.0075,16061.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-03",22,22,1555,,0.006,0.001,1149.1,0.0591,0.059,0.0083,19336.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-04",24,24,2156,,0.007,0.001,1442.3,0.0592,0.072,0.006,24268.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-05",24,24,613,,0.003,0.001,626,0.0592,0.033,0.0063,10531.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-09",24,24,681,,0.003,0.001,687.9,0.0594,0.046,0.013,11574.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-10",24,24,4668,,0.014,0.001,2775.8,0.059,0.417,0.0135,46709.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-11",24,24,625,,0.003,0.001,645,0.0591,0.033,0.0061,10857.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-12",10,10,253,,0.001,0.001,260.5,0.0595,0.014,0.0064,4381.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-19",15,15,161,,0.002,0.001,327.4,0.0593,0.04,0.0213,5509.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-20",24,24,600,,0.003,0.001,671.2,0.0591,0.034,0.006,11298.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-21",15,15,199,,0.001,0.001,290.7,0.0591,0.022,0.0115,4895.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-22",24,24,602,,0.003,0.001,689.4,0.0592,0.033,0.0058,11598.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-23",24,24,600,,0.003,0.001,645.9,0.0592,0.039,0.0071,10869,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-24",24,24,603,,0.003,0.001,644.2,0.0591,0.033,0.0061,10843.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-25",24,24,618,,0.003,0.001,652.1,0.0593,0.034,0.0061,10970.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-26",24,24,636,,0.003,0.001,643.6,0.0593,0.033,0.0065,10828.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-10",16,16,1230,,0.005,0.001,937.8,0.0593,0.087,0.0182,15778.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-11",24,24,2878,,0.01,0.001,1996.3,0.059,0.152,0.0076,33593.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-12",24,24,3015,,0.01,0.001,1944.4,0.0591,0.147,0.0077,32717.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-13",24,24,1761,,0.006,0.001,1263,0.0591,0.096,0.0074,21249.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-14",24,24,1920,,0.007,0.001,1360,0.0591,0.067,0.0062,22881.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-15",24,24,593,,0.003,0.001,624.9,0.0593,0.033,0.0071,10515.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-16",14,14,223,,0.002,0.001,326,0.0592,0.021,0.0114,5486.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-17",24,24,600,,0.003,0.001,640,0.0592,0.033,0.0062,10768.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-18",24,24,1256,,0.005,0.001,993.2,0.0593,0.053,0.0062,16710.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-19",21,21,1234,,0.005,0.001,943.9,0.059,0.061,0.012,15886.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-20",24,24,604,,0.003,0.001,650.5,0.0593,0.035,0.0065,10943.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-21",24,24,1341,,0.005,0.001,1052.2,0.0591,0.06,0.0069,17707.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-22",10,10,246,,0.001,0.001,240.8,0.0596,0.014,0.0079,4049.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-26",21,21,1652,,0.006,0.001,1233.3,0.0592,0.102,0.0157,20748.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-27",24,24,2651,,0.009,0.001,1855.6,0.059,0.114,0.007,31224.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-28",13,13,104,,0.001,0.001,204.1,0.0588,0.023,0.0216,3435.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-29",24,24,607,,0.003,0.001,680.5,0.0593,0.035,0.0062,11447.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-30",24,24,2442,,0.008,0.001,1597.2,0.0592,0.145,0.0083,26876.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-07-31",24,24,2648,,0.009,0.001,1718.2,0.0591,0.162,0.0085,28911.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-01",24,24,2198,,0.007,0.001,1470.8,0.059,0.124,0.0079,24748.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-02",24,24,608,,0.003,0.001,634.3,0.0593,0.055,0.0103,10671.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-03",24,24,2314,,0.008,0.001,1536.8,0.059,0.122,0.0088,25862.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-04",24,24,1990,,0.007,0.001,1362,0.0592,0.078,0.0064,22916,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-05",19,19,318,,0.002,0.0009,403.8,0.0586,0.027,0.0094,6794.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-06",16,16,383,,0.002,0.001,396.4,0.0592,0.022,0.0076,6671.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-08",10,10,25,,0.001,0.001,132.4,0.0601,0.042,0.031,2225,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-09",24,24,1078,,0.005,0.001,925.2,0.0591,0.074,0.0104,15572.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-10",24,24,586,,0.003,0.001,633,0.0592,0.037,0.0073,10650.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-11",15,15,276,,0.002,0.001,374.8,0.0592,0.031,0.0121,6306.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-12",24,24,1870,,0.007,0.001,1353.6,0.0593,0.094,0.0068,22774.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-13",24,24,3585,,0.012,0.001,2400.7,0.059,0.186,0.0078,40393.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-14",24,24,4095,,0.013,0.001,2516.4,0.0592,0.249,0.0095,42342.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-15",24,24,4719,,0.014,0.001,2817.7,0.0591,0.243,0.0088,47411.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-16",24,24,3299,,0.01,0.001,2063.8,0.059,0.163,0.0074,34727.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-17",24,24,4224,,0.013,0.001,2589.4,0.0591,9.736,0.3046,43567.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-18",24,24,5118,,0.016,0.001,3070.5,0.059,0.239,0.0083,51669.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-19",24,24,2887,,0.009,0.001,1876.8,0.059,0.113,0.0068,31584.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-20",24,24,4516,,0.014,0.001,2739.6,0.059,0.16,0.0065,46097.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-21",24,24,1830,,0.006,0.001,1261.5,0.0592,0.072,0.0065,21224,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-22",24,24,2468,,0.008,0.001,1630.1,0.0592,0.1,0.0069,27428.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-23",24,24,1985,,0.007,0.001,1351.5,0.0591,0.063,0.006,22741.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-24",24,24,4030,,0.013,0.001,2479.8,0.059,0.169,0.0074,41726.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-25",24,24,3207,,0.01,0.001,2028.1,0.0592,0.128,0.0072,34125.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-26",24,24,2795,,0.009,0.001,1796.3,0.059,0.111,0.0067,30229.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-27",24,24,2347,,0.008,0.001,1540.5,0.059,0.096,0.0063,25920.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-28",24,24,1798,,0.006,0.001,1255.3,0.0592,0.069,0.006,21122.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-29",24,24,580,,0.003,0.001,630.2,0.0593,0.032,0.0068,10602.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-08-31",22,22,348,,0.002,0.001,494.5,0.0597,0.039,0.0111,8316.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-01",24,24,624,,0.003,0.001,652.4,0.0593,0.034,0.0062,10975.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-02",24,24,627,,0.003,0.001,624.4,0.0593,0.032,0.006,10506.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-03",24,24,1240,,0.005,0.001,1061,0.0591,0.057,0.0063,17855.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-04",24,24,1178,,0.005,0.001,983.1,0.0592,0.701,0.0705,16540.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-05",24,24,3307,,0.01,0.001,2079.9,0.0591,0.147,0.0072,34992.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-06",24,24,4152,,0.013,0.001,2520.1,0.0591,0.173,0.0075,42403.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-07",24,24,2820,,0.009,0.001,1766.6,0.059,0.104,0.0069,29728.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-08",24,24,1607,,0.006,0.001,1125.3,0.0592,0.057,0.0064,18934.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-09",24,24,620,,0.003,0.001,619,0.0591,0.04,0.0078,10417.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-10",24,24,600,,0.003,0.001,610.4,0.0592,0.036,0.007,10270.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-11",11,11,292,,0.001,0.001,282.8,0.0591,0.015,0.0076,4759.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-16",24,24,543,,0.003,0.001,599.1,0.059,0.071,0.0214,10083.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-17",24,24,1962,,0.007,0.001,1332.7,0.0592,0.077,0.0067,22424.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-18",24,24,2612,,0.008,0.001,1679.2,0.0592,0.115,0.0071,28253.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-19",4,4,92,,0,0.001,75.3,0.0593,0.007,0.0133,1267.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-25",22,22,324,,0.002,0.001,486.5,0.0591,0.038,0.0102,8189.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-26",24,24,601,,0.003,0.001,654.1,0.0593,0.035,0.0063,11007.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-27",20,20,532,,0.003,0.001,582.5,0.0591,0.035,0.0112,9800.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-28",24,24,2581,,0.009,0.001,1796.8,0.059,0.11,0.007,30234.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-29",24,24,2070,,0.007,0.001,1406.8,0.0592,0.087,0.0067,23670.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-09-30",24,24,2156,,0.007,0.001,1426.9,0.0592,0.079,0.0066,24006.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-01",24,24,3029,,0.01,0.001,1907.1,0.0592,0.135,0.0075,32087.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-02",24,24,1371,,0.005,0.001,1025.3,0.0591,0.058,0.0065,17250.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-03",24,24,1894,,0.007,0.001,1316.4,0.059,0.066,0.006,22150.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-04",2,2,30,,0,0.001,23.4,0.0595,0.003,0.0135,393.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-05",18,18,1671,,0.006,0.001,1150.2,0.0592,0.087,0.0154,19354.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-06",24,24,613,,0.003,0.001,652.1,0.0591,0.035,0.0064,10975.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-07",24,24,593,,0.003,0.001,685.2,0.0592,0.036,0.0063,11529.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-08",1,1,2,,0,0.001,0.8,0.058,0,0.044,13.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-12",23,23,1676,,0.006,0.001,1227.6,0.0591,0.086,0.0133,20657.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-13",24,24,1979,,0.007,0.001,1403,0.0592,0.084,0.0066,23609.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-14",24,24,1786,,0.007,0.001,1313.9,0.0591,0.072,0.0061,22110.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-15",24,24,2375,,0.008,0.001,1624.9,0.059,0.097,0.0066,27343.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-16",24,24,1578,,0.006,0.001,1182.3,0.0593,0.067,0.0063,19891.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-17",24,24,2212,,0.008,0.001,1539.8,0.0591,0.088,0.0064,25909.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-18",9,9,213,,0.001,0.001,212.3,0.0592,0.012,0.0071,3572.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-20",21,21,335,,0.002,0.001,477.6,0.0594,0.031,0.0088,8034.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-21",24,24,566,,0.003,0.001,610.2,0.0591,0.033,0.0068,10269.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-26",24,24,359,,0.003,0.001,536.2,0.0593,0.037,0.0132,9021.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-27",12,12,275,,0.002,0.001,301.8,0.0592,0.016,0.0064,5077.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-03",6,6,0,,0,0.001,75.9,0.0595,0.011,0.0212,1276.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-04",24,24,1503,,0.006,0.001,1225.7,0.0591,0.07,0.0066,20623.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-05",24,24,699,,0.004,0.001,718.3,0.0593,0.034,0.0058,12084.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-06",24,24,588,,0.003,0.001,647.5,0.0593,0.033,0.006,10895,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-07",2,2,29,,0,0.001,26.3,0.06,0.002,0.011,441.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-03",3,3,0,,0,0.001,19.6,0.0593,0.005,0.035,329.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-04",1,1,0,,0,0.001,3.6,0.06,0,0.002,60.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-05",3,3,0,,0,0.001,15.3,0.059,0.002,0.014,258.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-12",3,3,0,,0,0.001,33.1,0.059,0.007,0.023,558,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-13",24,24,434,,0.003,0.001,613.4,0.0592,0.09,0.0205,10323,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-14",24,24,668,,0.004,0.001,714.3,0.059,0.034,0.0058,12016.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-15",24,24,588,,0.003,0.001,670.7,0.0591,0.039,0.0069,11285.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-16",24,24,697,,0.004,0.001,724.5,0.0591,0.033,0.0056,12192.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-17",1,1,5,,0,0.001,3.9,0.059,0,0.011,65.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-23",10,10,16,,0.001,0.001,145,0.0593,0.045,0.0351,2440.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-24",24,24,587,,0.003,0.001,655.8,0.0592,0.037,0.0065,11033.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-25",24,24,1063,,0.005,0.001,976.4,0.0591,0.045,0.0056,16429,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-26",24,24,601,,0.003,0.001,631.3,0.0592,0.032,0.0061,10622.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-27",24,24,606,,0.003,0.001,618.7,0.0591,0.034,0.0067,10412.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-29",9,9,0,,0.001,0.001,137.8,0.0593,0.038,0.0332,2317.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-30",24,24,549,,0.003,0.001,633.4,0.0593,0.034,0.0065,10655.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-03-31",11,11,276,,0.001,0.001,274.6,0.0591,0.015,0.0066,4624.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-07",9,9,4,,0.001,0.001,124.3,0.0602,0.022,0.0282,2090,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-08",24,24,601,,0.003,0.001,692.8,0.0591,0.047,0.0081,11655.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-09",11,11,256,,0.001,0.001,268.9,0.0591,0.015,0.0069,4524.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-17",10,10,44,,0.001,0.001,183.8,0.0592,0.031,0.0219,3094.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-18",24,24,601,,0.003,0.001,670.8,0.0592,0.035,0.0063,11286.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-19",24,24,600,,0.003,0.001,670.7,0.0592,0.035,0.0061,11290.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-20",11,11,260,,0.001,0.001,275.7,0.0592,0.015,0.0071,4639.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-24",10,10,24,,0.001,0.001,162.9,0.0592,0.018,0.0158,2741.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-25",24,24,603,,0.003,0.001,681.5,0.0591,0.037,0.0064,11472.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-26",24,24,601,,0.003,0.001,662.8,0.0592,0.033,0.006,11156,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-27",24,24,1570,,0.006,0.001,1173,0.0591,0.06,0.0058,19740.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-28",24,24,769,,0.004,0.001,742.4,0.0592,0.036,0.006,12493.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-29",24,24,744,,0.004,0.001,725.7,0.0591,0.037,0.0063,12213.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-04-30",24,24,1323,,0.005,0.001,1029.6,0.0593,0.043,0.0059,17318.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-01",9,9,223,,0.001,0.001,235.2,0.0591,0.014,0.0071,3958.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-03",14,14,186,,0.002,0.001,318.4,0.0595,0.03,0.0126,5354.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-04",24,24,751,,0.004,0.001,721.1,0.0591,0.041,0.0072,12135.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-05",4,4,105,,0.001,0.001,103.7,0.059,0.006,0.0065,1745.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-20",6,6,0,,0,0.001,66.3,0.0595,0.011,0.0212,1115.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-23",3,3,0,,0,0.001,28.8,0.059,0.008,0.04,485.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-24",2,2,0,,0,0.001,2.7,0.0585,0.001,0.03,45.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-20",10,10,0,,0,0.001,94.5,0.0591,0.017,0.0304,1589.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-23",13,13,0,,0.001,0.001,115.2,0.0596,0.023,0.026,1937.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-26",6,6,0,,0,0.001,61.8,0.0592,0.014,0.034,1040.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-27",7,7,0,,0,0.001,76.1,0.0594,0.013,0.0239,1279.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-28",5,5,0,,0,0.001,35.4,0.059,0.006,0.0316,596.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-12",10,10,7,,0.001,0.001,131.7,0.0593,0.016,0.0176,2217.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-14",10,10,0,,0,0.001,74.6,0.0592,0.013,0.0272,1255,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-15",11,11,0,,0.001,0.001,110.9,0.0596,0.033,0.0377,1863.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-17",20,20,556,,0.003,0.001,574.3,0.0592,0.051,0.0214,9665.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-18",24,24,4649,,0.014,0.001,2844.3,0.059,0.18,0.007,47862,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-19",24,24,3602,,0.011,0.001,2269.1,0.059,0.11,0.0048,38184.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-20",24,24,4061,,0.013,0.001,2524.6,0.059,0.115,0.0053,42483.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-21",24,24,1883,,0.007,0.001,1382.5,0.0591,0.047,0.0048,23262.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-22",24,24,2436,,0.008,0.001,1669.6,0.0592,0.074,0.0054,28092.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-23",24,24,2034,,0.007,0.001,1451.7,0.0591,0.048,0.0049,24427.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-24",24,24,3626,,0.012,0.001,2335.5,0.0591,0.347,0.0288,39300.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-25",24,24,3113,,0.01,0.001,2047.2,0.059,0.111,0.0062,34448.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-26",24,24,2826,,0.01,0.001,1893,0.059,0.093,0.0056,31854,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-27",24,24,2423,,0.008,0.001,1653.7,0.059,0.085,0.0055,27823.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-28",24,24,824,,0.004,0.001,798.1,0.0592,0.036,0.0057,13424.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-29",23,23,582,,0.003,0.001,618.6,0.0591,0.032,0.0061,10409.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-30",7,7,20,,0.001,0.001,125.4,0.0594,0.013,0.0164,2109.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-08-31",24,24,600,,0.003,0.001,658.3,0.0593,0.033,0.006,11078,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-01",24,24,1841,,0.007,0.001,1291,0.0592,0.045,0.0047,21722.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-02",24,24,600,,0.003,0.001,676.8,0.0591,0.034,0.006,11390.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-03",24,24,604,,0.003,0.001,678.2,0.0593,0.037,0.0065,11410.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-04",24,24,694,,0.003,0.001,684.8,0.0591,0.033,0.0059,11521,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-05",24,24,3265,,0.01,0.001,2073.7,0.0591,0.098,0.0057,34889.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-06",24,24,4207,,0.013,0.001,2636.7,0.059,0.125,0.0054,44367.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-07",24,24,2869,,0.009,0.001,1859.8,0.059,0.056,0.0042,31295.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-08",24,24,1641,,0.006,0.001,1209.9,0.0591,0.04,0.0048,20360,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-09",24,24,620,,0.004,0.001,714.3,0.0592,0.035,0.0059,12018,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-10",24,24,601,,0.004,0.001,709.2,0.0592,0.035,0.0058,11932.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-11",18,18,476,,0.002,0.001,492.6,0.0593,0.024,0.0062,8287.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-13",21,21,1445,,0.006,0.001,1177.2,0.059,0.061,0.0092,19811.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-14",24,24,1232,,0.005,0.001,1040.6,0.059,0.035,0.0044,17511.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-15",24,24,1794,,0.006,0.001,1286,0.0591,0.053,0.0053,21639.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-16",24,24,791,,0.004,0.001,786,0.0592,0.034,0.0054,13223.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-17",24,24,1977,,0.008,0.001,1511.6,0.0591,0.056,0.0045,25432.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-18",24,24,2603,,0.009,0.001,1835.9,0.059,0.085,0.005,30891,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-19",3,3,73,,0,0.001,57.3,0.0593,0.003,0.0087,963.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-28",20,20,1471,,0.006,0.001,1094.3,0.0591,0.058,0.0106,18416,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-29",24,24,2015,,0.007,0.001,1432.6,0.059,0.064,0.0055,24104,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-09-30",24,24,2194,,0.008,0.001,1522.9,0.0591,0.074,0.0057,25627.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-01",24,24,3194,,0.01,0.001,2073.7,0.0591,0.126,0.0068,34894.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-02",24,24,669,,0.003,0.001,677.8,0.0593,0.037,0.0067,11404.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-03",24,24,1931,,0.007,0.001,1344.7,0.059,0.063,0.0058,22627.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-04",24,24,2017,,0.008,0.001,1521.9,0.0591,0.06,0.005,25605.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-05",24,24,2858,,0.01,0.001,1967.1,0.059,0.08,0.0044,33102.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-06",24,24,612,,0.003,0.001,671.5,0.0591,0.034,0.006,11299.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-07",24,24,585,,0.004,0.001,700.3,0.0593,0.034,0.0059,11779.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-08",1,1,2,,0,0.001,0.7,0.063,0,0.087,11.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-09",5,5,0,,0,0.001,44.5,0.0612,0.01,0.0212,749.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-10",7,7,0,,0,0.001,56.2,0.0591,0.014,0.027,947.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-11",11,11,37,,0.001,0.001,178,0.0591,0.022,0.0305,2998.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-12",24,24,2771,,0.01,0.001,1945.3,0.059,0.061,0.0035,32732,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-13",24,24,2126,,0.007,0.001,1470.9,0.0592,0.054,0.005,24747.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-14",15,15,1913,,0.006,0.001,1257.1,0.059,0.057,0.0072,21152.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-15",24,24,3419,,0.011,0.001,2203.6,0.0591,0.115,0.0057,37080.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-16",24,24,3004,,0.01,0.001,1984.3,0.0591,0.094,0.0055,33383.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-17",24,24,3125,,0.01,0.001,2059.4,0.0591,0.086,0.0053,34651.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-18",24,24,1858,,0.007,0.001,1350.5,0.0591,0.059,0.0053,22724.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-19",10,10,65,,0.001,0.001,171.4,0.0592,0.018,0.0186,2883.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-20",24,24,602,,0.003,0.001,663.9,0.0591,0.033,0.006,11174.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-21",24,24,592,,0.003,0.001,653.8,0.0592,0.033,0.006,11002.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-22",24,24,600,,0.003,0.001,675.8,0.0592,0.034,0.0059,11372.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-23",5,5,107,,0.001,0.001,107.2,0.0592,0.006,0.0076,1803.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-25",19,19,296,,0.002,0.001,447.6,0.0592,0.028,0.0094,7532,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-26",24,24,636,,0.003,0.001,657.2,0.0592,0.035,0.0064,11057.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-01",17,17,216,,0.002,0.001,367.5,0.0592,0.026,0.0095,6184.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-02",24,24,1448,,0.006,0.001,1104.7,0.0591,0.05,0.0057,18590.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-03",24,24,730,,0.004,0.001,718.1,0.0591,0.034,0.0058,12084.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-04",24,24,1624,,0.006,0.001,1192.6,0.0592,0.045,0.0052,20072.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-05",24,24,2117,,0.007,0.001,1452.5,0.0591,0.069,0.0055,24442,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-06",24,24,688,,0.003,0.001,686.3,0.059,0.033,0.0058,11549.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-07",10,10,217,,0.001,0.001,230.1,0.0595,0.013,0.0102,3870.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-16",13,13,0,,0.001,0.001,175.4,0.0593,0.021,0.0172,2951.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-21",3,3,0,,0,0.001,34,0.0593,0.008,0.0303,572.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-22",24,24,446,,0.003,0.001,606.2,0.0592,0.038,0.0081,10199.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-23",11,11,270,,0.001,0.001,277.4,0.0593,0.015,0.0065,4667.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-26",21,21,259,,0.002,0.001,451,0.0593,0.038,0.011,7586.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-27",15,15,356,,0.002,0.001,377.4,0.0593,0.024,0.0081,6350.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-11-30",8,8,10,,0.001,0.001,127.2,0.0595,0.022,0.0245,2137.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-01",24,24,1748,,0.007,0.001,1295.2,0.0591,0.049,0.005,21793.8,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-02",24,24,1903,,0.007,0.001,1379.7,0.0591,0.055,0.0053,23216.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-03",24,24,705,,0.004,0.001,708.1,0.0591,0.039,0.0068,11914.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-04",2,2,33,,0,0.001,27.9,0.0595,0.002,0.0075,468.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-11",9,9,0,,0.001,0.001,108,0.0594,0.019,0.024,1816.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-12",24,24,665,,0.003,0.001,691,0.0592,0.042,0.0073,11625.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-13",24,24,4081,,0.013,0.001,2498.8,0.059,0.154,0.0072,42044.1,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-14",24,24,1977,,0.007,0.001,1370.9,0.0591,0.091,0.0065,23070.2,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-15",24,24,637,,0.003,0.001,653.2,0.0592,0.033,0.006,10992.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-16",2,2,36,,0,0.001,29.9,0.059,0.002,0.0095,504.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-21",9,9,1,,0.001,0.001,116.5,0.0593,0.019,0.0214,1960.5,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-22",24,24,614,,0.003,0.001,661.9,0.0592,0.034,0.0062,11138.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-23",24,24,1634,,0.006,0.001,1170.7,0.0592,0.049,0.0054,19701.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-24",24,24,624,,0.003,0.001,644.5,0.0591,0.036,0.0067,10848.9,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-25",24,24,624,,0.003,0.001,642.7,0.0593,0.032,0.006,10814.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-26",12,12,292,,0.001,0.001,292.5,0.0591,0.015,0.007,4920.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-27",8,8,22,,0.001,0.001,120.5,0.0599,0.021,0.0176,2025.7,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-28",24,24,621,,0.003,0.001,669.6,0.059,0.035,0.0062,11270.6,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-29",24,24,613,,0.003,0.001,657.2,0.0592,0.033,0.006,11060.3,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-30",2,2,29,,0,0.001,27.8,0.0605,0.002,0.014,467.4,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"4",,"2020-12-31",18,18,303,,0.002,0.001,424.7,0.0593,0.032,0.0118,7147,"Pipeline Natural Gas","Residual Oil","Tangentially-fired",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-07",23,23,880,,0.005,0.001,1056.9,0.0591,0.081,0.015,17785.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-08",15,15,1046,,0.005,0.001,946.1,0.059,0.016,0.0021,15917.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-26",14,14,109,,0.002,0.001,426.6,0.059,0.113,0.0346,7179,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-27",24,24,5124,,0.017,0.001,3459.4,0.059,0.754,0.0243,58210.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-28",24,24,2868,,0.011,0.001,2140.9,0.059,0.051,0.0025,36024.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-02",23,23,911,,0.005,0.001,1047.4,0.059,0.041,0.007,17625.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-03",24,24,2904,,0.011,0.001,2164.3,0.059,0.063,0.0033,36415.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-04",24,24,3175,,0.012,0.001,2308.4,0.059,0.07,0.0034,38845.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-11",6,6,0,,0.001,0.001,135.9,0.059,0.039,0.0332,2288.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-12",24,24,3170,,0.012,0.001,2367.9,0.059,1.217,0.1106,39841.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-13",22,22,2737,,0.01,0.001,2079.8,0.059,0.045,0.0023,34995.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-27",17,17,473,,0.003,0.001,662.7,0.0591,0.052,0.0131,11153.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-28",24,24,2829,,0.011,0.001,2179.6,0.059,0.046,0.0023,36680.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-29",24,24,2970,,0.011,0.001,2204.9,0.059,0.041,0.0021,37101.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-30",24,24,3984,,0.014,0.001,2812.7,0.059,0.07,0.0024,47329.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-07-31",24,24,3966,,0.014,0.001,2819.9,0.059,0.078,0.0026,47448.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-01",24,24,3180,,0.012,0.001,2351.4,0.059,0.048,0.0022,39564.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-02",24,24,3481,,0.012,0.001,2460.6,0.059,0.041,0.002,41400,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-03",24,24,3261,,0.012,0.001,2378.5,0.059,0.04,0.002,40024.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-04",1,1,41,,0,0.001,28.5,0.059,0.001,0.003,479.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-13",13,13,486,,0.003,0.001,582.1,0.0592,1.954,0.2852,9793.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-14",24,24,6325,,0.021,0.001,4089.1,0.059,3.391,0.1535,68809.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-15",24,24,5663,,0.019,0.001,3815.6,0.059,0.132,0.0032,64204.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-16",24,24,5407,,0.018,0.001,3634.8,0.059,0.108,0.0028,61164.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-17",24,24,7565,,0.025,0.001,4881.2,0.059,2.651,0.0465,82139.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-18",24,24,7490,,0.024,0.001,4843.6,0.059,0.163,0.0034,81504.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-19",24,24,6989,,0.023,0.001,4569,0.059,0.161,0.0035,76886.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-20",24,24,5721,,0.019,0.001,3782.1,0.059,0.111,0.0028,63642,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-21",24,24,5432,,0.018,0.001,3602.8,0.059,0.088,0.0025,60619.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-22",24,24,4131,,0.014,0.001,2800.4,0.059,0.047,0.002,47118.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-23",24,24,4693,,0.016,0.001,3135.1,0.059,0.053,0.002,52755.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-24",24,24,6409,,0.021,0.001,4233.6,0.059,0.123,0.0029,71242.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-25",24,24,8104,,0.027,0.001,5304.7,0.059,0.225,0.0049,89260.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-26",24,24,6150,,0.021,0.001,4061.1,0.059,0.122,0.003,68333,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-27",24,24,5998,,0.02,0.001,3945,0.059,0.117,0.0031,66384.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-28",22,22,5036,,0.017,0.001,3311.9,0.059,0.082,0.0025,55723.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-03",3,3,0,,0,0.001,39.1,0.0583,0.011,0.0193,658.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-04",24,24,2558,,0.01,0.001,2030.5,0.059,0.826,0.1157,34164.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-05",24,24,5992,,0.02,0.001,3896.3,0.059,0.17,0.0043,65559.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-06",24,24,7043,,0.023,0.001,4566.5,0.059,0.177,0.0043,76835.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-07",24,24,4316,,0.015,0.001,2895,0.059,0.092,0.0037,48714.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-08",24,24,3607,,0.013,0.001,2490.4,0.059,0.079,0.0037,41903.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-09",24,24,3011,,0.011,0.001,2211.8,0.059,0.065,0.0033,37216.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-10",3,3,174,,0.001,0.001,152.2,0.059,0.004,0.003,2561.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-13",2,2,0,,0,0.001,29.3,0.059,0.015,0.0555,494,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-14",24,24,1151,,0.006,0.001,1246.8,0.059,0.088,0.0141,20980.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-15",24,24,2968,,0.011,0.001,2247.2,0.059,0.067,0.0034,37813.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-16",1,1,44,,0,0.001,31.3,0.059,0.001,0.003,527.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-28",17,17,560,,0.004,0.001,726.7,0.0591,0.192,0.0532,12226.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-29",24,24,3282,,0.012,0.001,2441.3,0.059,0.073,0.0034,41081.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-09-30",24,24,5524,,0.018,0.001,3626.8,0.059,0.142,0.0043,61028,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-01",24,24,4745,,0.016,0.001,3264.1,0.059,0.112,0.0036,54926.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-02",24,24,2721,,0.011,0.001,2088.4,0.059,0.06,0.0033,35141.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-03",24,24,3419,,0.012,0.001,2455,0.059,0.076,0.0035,41312.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-04",1,1,70,,0,0.001,47.1,0.059,0.002,0.004,792,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-05",19,19,3080,,0.011,0.001,2225.1,0.0591,0.163,0.0259,37443.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-06",24,24,6783,,0.022,0.001,4450.7,0.059,0.186,0.0045,74894.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-07",3,3,506,,0.002,0.001,333.4,0.059,0.009,0.0033,5608.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-12",16,16,1282,,0.005,0.001,1080.4,0.0591,0.091,0.0201,18179.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-13",24,24,6184,,0.02,0.001,4029.6,0.059,0.157,0.0044,67804.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-14",24,24,4095,,0.015,0.001,2886.2,0.059,0.084,0.0032,48563.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-15",24,24,4971,,0.017,0.001,3441.8,0.059,0.131,0.0038,57914.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-16",24,24,4851,,0.017,0.001,3374.7,0.059,0.126,0.0038,56784.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-17",23,23,5407,,0.018,0.001,3589.6,0.059,0.137,0.0041,60404.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"5",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-27",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-28",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-29",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-30",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-01-31",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-27",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-28",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-02-29",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-25",5,4.33,1402.74,,0.003,0.001,561.734,0.059,0.036,0.01,9452.757,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-06",14,13.21,4054.04,,0.008,0.001,1653.606,0.059,0.128,0.0116,27826.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-23",7,6.95,2031.49,,0.004,0.001,858.723,0.059,0.059,0.01,14449.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-24",10,8.15,2365.6,,0.005,0.001,976.088,0.059,0.067,0.0175,16425.006,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-25",9,8.33,2329.71,,0.005,0.001,959.41,0.059,0.058,0.0082,16145.667,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-26",9,8.31,2558.72,,0.005,0.001,1041.576,0.059,0.061,0.0083,17526.444,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-27",8,7.47,2298.84,,0.005,0.001,941.224,0.059,0.058,0.0085,15837.047,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-28",9,8.35,2638.67,,0.005,0.001,1072.391,0.059,0.065,0.0081,18043.824,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-29",8,7.36,2229.22,,0.005,0.001,912.342,0.059,0.068,0.0114,15350.506,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-15",18,17.56,3997.34,,0.009,0.001,1687.566,0.059,0.1,0.0076,28399.362,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-26",9,7.8,2054.33,,0.005,0.001,893.276,0.059,0.055,0.017,15031.859,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-27",17,16.27,4776.88,,0.01,0.001,1926.011,0.059,0.098,0.0069,32409.913,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-28",8,7.13,2169.13,,0.004,0.001,867.964,0.059,0.041,0.0075,14604.657,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-01",8,7.06,2138,,0.004,0.001,865.068,0.059,0.047,0.0118,14557.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-02",9,8.05,2451.4,,0.005,0.001,984.73,0.059,0.043,0.0103,16569.03,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-03",10,8.85,2714.24,,0.005,0.001,1084.983,0.059,0.046,0.0077,18254.311,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-04",8,7.01,2060.61,,0.004,0.001,831.153,0.059,0.036,0.0071,13985.273,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-09",9,7.47,2186.76,,0.005,0.001,899.189,0.059,0.056,0.016,15129.012,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-10",9,7.7,2318.45,,0.005,0.001,934.381,0.059,0.059,0.0154,15721.621,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-11",9,7.49,2242.81,,0.005,0.001,899.784,0.059,0.054,0.0164,15141.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-18",8,7.2,2155.74,,0.004,0.001,870.158,0.0591,0.054,0.0308,14641.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-19",9,7.09,2149.97,,0.004,0.001,862.055,0.059,0.054,0.0266,14506.297,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-21",9,7.27,2132.62,,0.004,0.0009,865.688,0.059,0.058,0.009,14569.158,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-22",8,7.59,2252.22,,0.005,0.001,910.373,0.059,0.054,0.0084,15319.774,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-23",10,8.67,2672.77,,0.005,0.001,1069.011,0.059,0.062,0.0086,17987.246,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-24",9,8.55,2642.01,,0.005,0.001,1051.481,0.059,0.062,0.0079,17693.755,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-25",9,7.87,2423.71,,0.005,0.001,966.833,0.059,0.056,0.0177,16268.819,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-26",10,8.87,2755.99,,0.006,0.001,1099.924,0.059,0.065,0.0166,18507.462,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-27",8,6.92,2099,,0.004,0.001,848.142,0.059,0.05,0.017,14273.573,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-28",7,6.65,1993.05,,0.004,0.001,802.06,0.059,0.046,0.0083,13495.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-29",2,1.45,208.2,,0.001,0.001,101.345,0.059,0.007,0.01,1705.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-01",7,6.93,2107.38,,0.004,0.001,837.078,0.059,0.054,0.009,14082.708,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-02",9,7.03,2133.35,,0.004,0.001,846.83,0.059,0.052,0.0194,14250.522,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-03",8,7.51,2278.28,,0.005,0.001,912.64,0.059,0.055,0.0081,15358.822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-04",7,6.96,2117.46,,0.004,0.001,845.646,0.059,0.05,0.0077,14229.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-05",10,8.43,2509.86,,0.005,0.001,1006.052,0.059,0.06,0.0144,16928.339,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-06",12,10.67,3314.3,,0.007,0.001,1314.249,0.059,0.074,0.0088,22115.165,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-07",12,10.49,3249.18,,0.006,0.001,1281.072,0.059,0.073,0.0142,21558.499,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-08",15,13.45,3838.6,,0.008,0.001,1537.883,0.059,0.086,0.0093,25881.166,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-09",10,8.49,2573.41,,0.005,0.001,1028.756,0.059,0.06,0.0146,17312.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-10",13,11.99,3732.44,,0.007,0.001,1480.612,0.059,0.082,0.013,24913.082,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-11",12,10.22,3181.24,,0.006,0.001,1265.974,0.0591,0.07,0.0167,21302.957,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-12",12,10.43,3257.56,,0.007,0.001,1288.156,0.059,0.072,0.012,21675.186,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-13",12,11.29,3597.73,,0.007,0.001,1416.379,0.059,0.08,0.0078,23833.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-14",9,8.2,2523.16,,0.005,0.001,997.793,0.059,0.059,0.0088,16789.951,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-15",8,7.02,2113.48,,0.004,0.001,844.477,0.059,0.05,0.0188,14213.078,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-16",9,8.02,2459.71,,0.005,0.001,980.763,0.059,0.057,0.017,16501.745,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-17",9,8.48,2589.61,,0.005,0.001,1030.14,0.059,0.06,0.0079,17336.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-18",8,7.29,2243.2,,0.005,0.001,894.843,0.059,0.054,0.0089,15057.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-19",8,7.29,2207.81,,0.004,0.001,883.042,0.059,0.053,0.0088,14859.196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-20",9,7.49,2230.17,,0.005,0.001,892.156,0.059,0.053,0.0166,15011.738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-21",12,10.47,3273,,0.007,0.001,1291.723,0.059,0.074,0.0131,21737.908,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-22",10,8.45,2548.97,,0.005,0.001,1014.317,0.0591,0.058,0.0151,17067.271,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-23",12,10.23,2516.8,,0.005,0.001,1033.634,0.059,0.059,0.014,17390.011,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-24",10,8.47,2489.56,,0.005,0.001,999.535,0.0591,0.059,0.0143,16819.158,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-25",9,7.64,2277.92,,0.005,0.001,922.2,0.059,0.059,0.0146,15516.508,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-26",10,8.22,2508.84,,0.005,0.001,1001.422,0.059,0.058,0.0265,16853.649,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-27",12,11.04,3543.96,,0.007,0.001,1401.535,0.059,0.078,0.0132,23584.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-28",12,11.97,3298.49,,0.007,0.001,1333.702,0.059,0.072,0.0068,22441.885,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-29",12,10.42,3266.48,,0.007,0.001,1294.788,0.059,0.075,0.0113,21787.716,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-30",12,11.55,3668.57,,0.007,0.001,1449.192,0.059,0.082,0.0074,24384.483,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-07-31",13,11.87,3689.28,,0.007,0.001,1463.734,0.059,0.082,0.0156,24627.966,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-01",10,9.32,2905.04,,0.006,0.001,1156.423,0.059,0.066,0.0079,19458.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-02",9,8.07,2518.78,,0.005,0.001,1001.552,0.059,0.058,0.0087,16852.323,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-03",8,6.87,2100.58,,0.004,0.001,839.821,0.059,0.049,0.0166,14132.738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-04",8,6.89,2101.24,,0.004,0.001,842.947,0.059,0.05,0.0183,14184.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-06",7,6.95,2032.47,,0.004,0.001,821.712,0.059,0.053,0.0087,13826.214,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-07",8,7.15,2095.3,,0.004,0.001,843.64,0.059,0.051,0.0091,14194.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-08",8,7.12,2156.44,,0.004,0.001,862.956,0.059,0.052,0.009,14520.022,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-09",9,7.5,1970.27,,0.004,0.001,807.714,0.059,0.055,0.0131,13589.963,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-10",9,8.28,2558.06,,0.005,0.001,1021.792,0.059,0.06,0.0081,17194.378,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-11",10,9.32,2868.6,,0.006,0.001,1146.204,0.059,0.066,0.0083,19287.848,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-12",11,10.57,3318.63,,0.007,0.001,1318.481,0.059,0.075,0.0075,22184.532,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-13",12,11.72,3726.44,,0.007,0.001,1479.678,0.059,0.084,0.0073,24896.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-14",20,19.72,5890.92,,0.012,0.001,2337.868,0.059,0.122,0.0067,39337.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-15",15,13.46,4096.62,,0.008,0.001,1627.852,0.059,0.092,0.0109,27389.103,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-16",19,17.87,4465.14,,0.009,0.001,1824.429,0.059,0.099,0.012,30700.047,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-17",18,17.05,4990.38,,0.01,0.001,1988.335,0.059,0.106,0.0073,33455.364,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-18",20,19.82,5206.9,,0.011,0.001,2102.938,0.059,0.112,0.0067,35386.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-19",21,20.77,5354.37,,0.011,0.001,2180.36,0.059,0.117,0.0068,36687.828,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-20",23,22.07,5654.8,,0.012,0.001,2279.337,0.059,0.116,0.0083,38352.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-21",14,13.82,4260.36,,0.009,0.001,1688.98,0.059,0.091,0.0069,28422.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-22",19,17.97,4775.65,,0.01,0.001,1937.061,0.059,0.105,0.0071,32593.893,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-23",12,11.14,3464.8,,0.007,0.001,1377.592,0.059,0.078,0.008,23181.386,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-24",13,12.1,3801.02,,0.008,0.001,1508.632,0.059,0.083,0.0076,25384.304,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-25",13,11.8,3764.99,,0.008,0.001,1486.55,0.059,0.082,0.0088,25012.337,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-26",18,16.6,5216.01,,0.01,0.001,2055.193,0.059,0.119,0.0111,34583.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-27",17,16.13,4076.75,,0.008,0.001,1656.196,0.059,0.098,0.0082,27868.525,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-28",11,9.94,3127.92,,0.006,0.001,1242.42,0.059,0.071,0.0087,20904.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-29",8,6.19,1414.8,,0.003,0.001,599.557,0.0591,0.045,0.0223,10089.674,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-30",8,6.65,2031.16,,0.004,0.001,810.987,0.059,0.049,0.0169,13646.535,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-08-31",8,6.7,2054.64,,0.004,0.001,815.83,0.059,0.05,0.0169,13728.532,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-01",11,9.65,2588.5,,0.005,0.001,1053.73,0.059,0.06,0.0175,17730.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-02",8,7.2,2232.88,,0.005,0.001,899.252,0.059,0.054,0.0091,15133.649,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-03",18,16.95,4075.23,,0.009,0.001,1690.56,0.059,0.094,0.0078,28443.464,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-04",19,17.65,4377.75,,0.009,0.001,1809.155,0.059,0.098,0.0112,30443.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-05",17,16.17,4313.23,,0.009,0.001,1764.128,0.059,0.097,0.0075,29685.919,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-06",17,16.35,4630.85,,0.009,0.001,1865.115,0.059,0.101,0.0074,31383.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-07",16,14.9,3663.74,,0.008,0.001,1511.887,0.059,0.083,0.0108,25443.225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-08",12,10.77,1927.22,,0.004,0.001,849.864,0.059,0.049,0.0153,14300.322,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-09",10,8.9,2585.78,,0.005,0.001,1051.762,0.059,0.062,0.0131,17700.142,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-10",10,8.89,2746.23,,0.006,0.001,1107.111,0.059,0.063,0.0111,18631.266,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-11",13,10.24,2285.81,,0.005,0.001,968.422,0.059,0.112,0.0383,16294.781,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-12",12,10.89,3129.03,,0.006,0.001,1271.111,0.059,0.072,0.0152,21391.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-13",9,7.19,2146.62,,0.004,0.001,871.431,0.059,0.055,0.0199,14663.213,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-14",12,10.89,3426.21,,0.007,0.001,1375.771,0.059,0.077,0.0118,23151.265,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-15",9,8.39,2565.91,,0.005,0.001,1036.861,0.059,0.061,0.0081,17446.427,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-16",12,11.15,3508.79,,0.007,0.001,1411.446,0.059,0.08,0.0083,23750.863,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-17",11,10.4,3217.66,,0.007,0.001,1294.35,0.059,0.076,0.0081,21783.632,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-18",10,9.65,2962.79,,0.006,0.001,1192.137,0.059,0.069,0.0078,20062.311,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-19",9,8.39,2557.46,,0.005,0.001,1032.525,0.059,0.06,0.0081,17372.886,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-20",10,9.14,2830.96,,0.006,0.001,1130.932,0.059,0.065,0.0084,19030.722,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-21",13,12.38,3802.14,,0.008,0.001,1509.42,0.059,0.082,0.0091,25397.786,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-22",13,11.7,3400.59,,0.007,0.001,1373.63,0.0591,0.081,0.0227,23111.973,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-23",10,8.68,2619.48,,0.005,0.001,1046.797,0.059,0.059,0.0199,17616.039,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-24",12,10.67,3329.58,,0.007,0.001,1330.169,0.059,0.075,0.0178,22384.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-25",8,6.95,2122.64,,0.004,0.001,857.443,0.059,0.049,0.0095,14428.292,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-26",8,6.97,2024.69,,0.004,0.001,833.902,0.059,0.05,0.0158,14031.238,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-27",8,6.96,2111.29,,0.004,0.001,849.763,0.059,0.051,0.0099,14300.703,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-28",7,5.92,1775.93,,0.004,0.001,724.238,0.059,0.045,0.0146,12189.63,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-29",13,12.63,3787.07,,0.008,0.001,1524.06,0.059,0.083,0.0073,25646.557,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-09-30",15,13.01,3677.68,,0.008,0.001,1490.642,0.059,0.087,0.0151,25082.251,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-01",12,10.62,3369.12,,0.007,0.001,1342.657,0.059,0.076,0.012,22592.821,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-02",12,10.67,3244.14,,0.007,0.001,1298.064,0.059,0.071,0.0164,21841.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-03",13,12.62,3927.84,,0.008,0.001,1565.59,0.059,0.085,0.0074,26347.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-04",14,12.26,3492.53,,0.007,0.001,1417.014,0.059,0.082,0.0091,23845.959,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-05",20,19.78,6028.42,,0.012,0.001,2404.126,0.059,0.125,0.0066,40452.128,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-06",13,11.18,3506.97,,0.007,0.001,1401.187,0.059,0.082,0.0152,23576.686,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-07",9,7.38,2238.01,,0.005,0.0009,904.294,0.059,0.057,0.0082,15217.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-08",9,7.4,2107.44,,0.004,0.001,866.791,0.0591,0.069,0.0119,14585.391,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-09",12,10.12,3155.95,,0.006,0.001,1258.389,0.059,0.071,0.0111,21175.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-10",9,7.35,2203.7,,0.004,0.0009,887.05,0.059,0.056,0.0086,14927.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-11",9,7.38,2245.49,,0.005,0.001,903.269,0.059,0.059,0.0086,15198.847,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-12",12,11.78,3594.08,,0.007,0.001,1436.348,0.059,0.078,0.0072,24167.802,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-13",19,17.65,3946.95,,0.008,0.001,1660,0.059,0.093,0.0077,27935.365,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-14",11,9.13,2833.52,,0.006,0.001,1129.255,0.0591,0.068,0.0123,19001.752,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-15",13,11.38,3541.38,,0.007,0.0009,1412.143,0.059,0.08,0.0073,23763.829,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-16",16,15.04,4321.27,,0.009,0.001,1730.426,0.059,0.096,0.0081,29117.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-17",10,8.11,2445.2,,0.005,0.0009,981.355,0.0591,0.059,0.0124,16510.762,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-18",9,7.61,2273.64,,0.005,0.001,913.717,0.0591,0.058,0.0077,15375.593,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-19",9,7.9,2410.7,,0.005,0.001,968.235,0.059,0.057,0.0191,16294.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-20",18,16.5,4578.4,,0.009,0.001,1849.79,0.0591,0.101,0.0138,31124.895,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-21",9,7.93,2457.09,,0.005,0.001,986.586,0.059,0.055,0.0137,16603.001,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-22",8,7.22,2224.03,,0.005,0.001,894.101,0.059,0.055,0.0093,15046.989,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-23",18,16.84,5056.76,,0.01,0.001,2000.656,0.059,0.11,0.0081,33667.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-24",16,14.03,4125.07,,0.008,0.001,1657.105,0.059,0.098,0.0131,27881.411,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-25",9,8.88,2837.88,,0.006,0.001,1132.052,0.059,0.065,0.0076,19050.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-26",18,14.9,4572.13,,0.009,0.001,1829.424,0.0591,0.114,0.0163,30785.105,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-27",17,13.94,3958.46,,0.008,0.001,1597.123,0.059,0.1,0.0149,26874.546,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-28",17,13.83,3955.92,,0.008,0.001,1600.775,0.0591,0.097,0.0179,26936.651,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-29",8,7.15,2202.8,,0.004,0.001,886.662,0.059,0.054,0.0091,14918.874,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-30",18,17.15,4666.53,,0.01,0.001,1888.032,0.059,0.104,0.0074,31772.528,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-10-31",10,9.62,2806.5,,0.006,0.001,1140.728,0.059,0.065,0.0084,19196.876,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-01",22,20.7,4933.77,,0.01,0.001,2073.424,0.059,0.115,0.0075,34886.586,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-02",13,12.07,3920,,0.008,0.001,1564.499,0.0591,0.089,0.0072,26324.371,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-03",15,13.33,2931.39,,0.006,0.001,1269.61,0.059,0.082,0.0097,21363.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-04",11,10.07,3053,,0.006,0.001,1238.476,0.059,0.072,0.0078,20839.857,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-05",24,23.35,5987.7,,0.013,0.001,2499.405,0.059,0.136,0.0073,42055.565,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-06",10,7.18,2163.47,,0.004,0.001,884.386,0.059,0.058,0.0238,14883.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-08",9,8.05,1781,,0.004,0.001,774.07,0.059,0.049,0.0072,13022.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-09",16,15.21,3806.72,,0.008,0.001,1603.697,0.059,0.094,0.0077,26983.159,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-10",17,14.48,3905.12,,0.008,0.001,1617.893,0.059,0.099,0.0117,27224.932,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-11",10,8.1,2335.65,,0.005,0.001,952.46,0.059,0.06,0.017,16027.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-12",9,7.4,2237.8,,0.005,0.001,907.62,0.0591,0.06,0.0089,15273.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-14",9,7.21,2159.04,,0.004,0.001,884.725,0.059,0.057,0.021,14887.372,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-15",10,8.12,2004.4,,0.004,0.001,836.433,0.0591,0.054,0.0206,14072.869,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-16",11,9.39,2466.56,,0.005,0.001,1017.032,0.059,0.067,0.0102,17111.956,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-17",11,8.17,2354.7,,0.005,0.001,961.192,0.059,0.059,0.0299,16174.013,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-18",8,7.03,2098.65,,0.004,0.001,849.052,0.059,0.052,0.0099,14286.935,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-19",9,7.1,2172.8,,0.004,0.0009,879.326,0.059,0.051,0.016,14798.177,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-20",13,11.7,3365.5,,0.007,0.001,1362.633,0.059,0.077,0.0153,22928.093,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-23",9,7.08,1185.4,,0.003,0.001,540.938,0.059,0.04,0.0211,9102.314,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-24",8,7.27,2238.92,,0.005,0.001,904.487,0.059,0.057,0.0095,15219.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-25",8,6.97,1707.38,,0.004,0.001,712.191,0.0591,0.045,0.0206,11983.352,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-27",9,8.78,2462.44,,0.005,0.001,1005.902,0.059,0.062,0.0089,16923.532,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-28",8,7.05,1119.95,,0.003,0.001,510.3,0.059,0.027,0.0198,8589.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-29",9,8.68,2618.32,,0.005,0.001,1056.7,0.059,0.063,0.009,17783.304,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-11-30",21,18.45,4547.4,,0.01,0.001,1887.26,0.059,0.105,0.0201,31758.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-01",9,8.23,2426.45,,0.005,0.001,990.702,0.059,0.06,0.0091,16669.975,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-02",18,16.48,4715.26,,0.01,0.001,1918.722,0.059,0.101,0.0152,32288.829,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-03",8,7.01,2165.1,,0.004,0.001,882.08,0.059,0.059,0.0116,14843.244,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-04",9,7.92,2412.69,,0.005,0.001,986.118,0.059,0.06,0.0191,16593.742,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-13",10,8.22,1703.13,,0.004,0.001,793.001,0.059,0.063,0.03,13342.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-14",17,16.83,3997.15,,0.009,0.001,1709.784,0.059,0.094,0.0069,28770.466,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-15",8,6.7,2006.64,,0.004,0.001,816.01,0.059,0.051,0.016,13730.274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-16",20,15.64,3908.49,,0.008,0.001,1647.017,0.059,0.106,0.0238,27711.298,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-17",17,15.67,4120.94,,0.009,0.001,1702.466,0.059,0.095,0.0115,28646.674,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-18",20,18.7,5192.05,,0.011,0.001,2144.52,0.059,0.117,0.012,36088.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-19",8,7.23,2044.55,,0.004,0.001,860.165,0.059,0.056,0.01,14472.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-20",9,7.11,2135.28,,0.004,0.001,877.28,0.059,0.054,0.0158,14761.201,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-21",16,14.88,3357.12,,0.007,0.001,1455.132,0.059,0.082,0.0115,24485.008,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-22",9,7.87,2280.86,,0.005,0.001,944.386,0.059,0.057,0.0194,15889.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-23",18,16.15,3626.05,,0.008,0.001,1564.34,0.059,0.087,0.0163,26325.005,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-24",8,7.15,2176.71,,0.005,0.001,894.131,0.059,0.059,0.0108,15045.397,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-25",9,7.12,1017.8,,0.002,0.001,495.111,0.059,0.035,0.0189,8333.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-27",9,7.15,2094.04,,0.004,0.001,869.96,0.059,0.057,0.014,14638.842,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-28",9,7.92,2334.59,,0.005,0.001,958.424,0.059,0.058,0.0174,16129.091,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-29",8,6.75,2099.43,,0.004,0.001,854.41,0.059,0.053,0.0159,14377.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-30",8,6.97,2130.81,,0.004,0.001,868.403,0.059,0.054,0.0151,14613.953,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-27",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-28",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-29",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-30",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-01-31",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-27",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-28",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-02-29",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-24",4,3.28,1068.08,,0.002,0.001,427.564,0.059,0.02,0.0088,7194.628,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-06",16,15.44,4591.48,,0.01,0.001,1912.009,0.059,0.116,0.0091,32173.539,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-23",7,6.62,2002.86,,0.004,0.001,833.294,0.059,0.052,0.0134,14019.598,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-24",10,7.9,2320.65,,0.005,0.001,953.387,0.059,0.051,0.018,16041.924,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-25",9,8.16,2317.16,,0.005,0.001,945.924,0.059,0.05,0.0078,15918.704,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-26",9,8.11,2528.51,,0.005,0.001,1025.337,0.059,0.053,0.0078,17253.522,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-27",8,7.3,2274,,0.005,0.001,925.42,0.059,0.048,0.0078,15572.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-28",9,8.15,2607.97,,0.005,0.001,1055.087,0.059,0.054,0.0073,17752.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-29",8,7.16,2221.02,,0.005,0.001,898.354,0.059,0.047,0.0081,15116.078,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-15",18,17.4,3992.06,,0.008,0.001,1677.324,0.059,0.092,0.0072,28224.446,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-26",9,8.04,2082.13,,0.005,0.001,912.512,0.059,0.051,0.0157,15355.345,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-27",8,7.4,2246.16,,0.005,0.001,895.172,0.059,0.041,0.0069,15060.794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-28",17,16.19,5090.64,,0.01,0.001,2032.67,0.059,0.095,0.0065,34205.489,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-01",8,6.83,2113.52,,0.004,0.001,847.073,0.059,0.048,0.0146,14252.439,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-02",9,7.83,2429.41,,0.005,0.001,971.346,0.059,0.05,0.0119,16344.438,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-03",10,8.66,2704.62,,0.005,0.001,1074.158,0.059,0.054,0.0108,18073.376,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-04",8,6.87,2076.27,,0.004,0.001,828.07,0.059,0.044,0.0094,13932.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-09",8,7.22,2177.8,,0.004,0.001,886.596,0.059,0.053,0.0096,14918.662,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-10",8,7.49,2315.1,,0.005,0.001,924.244,0.059,0.049,0.0075,15551.446,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-11",8,7.27,2231.86,,0.004,0.001,888.465,0.059,0.047,0.0083,14950.934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-18",8,7.02,2155,,0.004,0.001,861.672,0.0591,0.047,0.0069,14499.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-19",9,6.91,2134.1,,0.004,0.001,851.779,0.059,0.045,0.0258,14331.475,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-21",8,7.13,2152.01,,0.004,0.001,863.725,0.059,0.047,0.0089,14533.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-22",8,7.32,2242.34,,0.005,0.001,899.018,0.059,0.047,0.0086,15127.206,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-23",9,8.47,2664.54,,0.005,0.001,1060.732,0.059,0.054,0.007,17848.077,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-24",9,8.34,2633.64,,0.005,0.001,1044.635,0.059,0.054,0.0073,17577.561,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-25",9,8.05,2458.39,,0.005,0.001,985.669,0.059,0.049,0.0166,16585.576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-26",11,9.14,2810.66,,0.006,0.001,1127.832,0.059,0.054,0.0143,18979.282,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-27",9,7.2,2145.87,,0.004,0.001,873.848,0.059,0.045,0.02,14702.942,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-28",7,7,2044,,0.004,0.001,831.9,0.059,0.043,0.0071,14000.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-29",7,6.33,966.84,,0.002,0.001,444.236,0.059,0.022,0.0061,7478.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-01",8,7.13,2152,,0.004,0.001,857.985,0.0591,0.05,0.012,14435.616,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-02",9,7.19,2181.3,,0.004,0.001,868.876,0.059,0.045,0.0168,14622.848,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-03",9,7.72,2338.13,,0.005,0.001,938.647,0.059,0.048,0.0113,15793.192,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-04",8,7.17,2167.68,,0.004,0.001,870.14,0.059,0.045,0.018,14640.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-05",11,8.6,2555.8,,0.005,0.001,1027.7,0.0591,0.052,0.0183,17290.945,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-06",11,10.43,3326.21,,0.007,0.001,1312.241,0.059,0.064,0.0065,22079.891,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-07",11,10.24,3251,,0.006,0.001,1275.56,0.059,0.062,0.0071,21462.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-08",14,13.19,3853.58,,0.008,0.001,1536.935,0.059,0.075,0.0069,25862.001,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-09",9,8.24,2575.36,,0.005,0.001,1024.192,0.059,0.052,0.0078,17233.036,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-10",12,11.77,3725.22,,0.007,0.001,1474.392,0.059,0.071,0.0063,24807.014,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-11",11,10,3174.21,,0.006,0.001,1260.068,0.059,0.06,0.0133,21203.432,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-12",11,10.23,3257.62,,0.006,0.001,1286.614,0.059,0.062,0.007,21648.042,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-13",13,11.47,3640.52,,0.007,0.001,1438.393,0.059,0.069,0.0111,24204.303,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-14",10,8.43,2578.8,,0.005,0.001,1021.786,0.059,0.051,0.0122,17192.727,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-15",9,7.22,2152.24,,0.004,0.001,863.89,0.059,0.044,0.0226,14534.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-16",10,8.22,2499.45,,0.005,0.001,1000.762,0.059,0.049,0.0204,16838.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-17",10,8.73,2629.68,,0.005,0.001,1048.215,0.059,0.053,0.013,17638.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-18",9,7.47,2271.96,,0.005,0.001,909.556,0.059,0.047,0.0139,15304.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-19",9,7.47,2236.64,,0.005,0.001,897.606,0.059,0.046,0.0144,15105.043,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-20",8,7.29,2211.96,,0.004,0.001,879.678,0.059,0.046,0.0081,14803.043,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-21",11,10.29,3258.94,,0.006,0.001,1279.687,0.059,0.063,0.0072,21534.148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-22",9,8.23,2529.43,,0.005,0.001,1000.951,0.059,0.05,0.0078,16843.333,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-23",13,12.95,3320,,0.007,0.001,1345.545,0.059,0.063,0.006,22642.125,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-24",13,11.8,3007.43,,0.006,0.001,1233.631,0.059,0.066,0.008,20755.241,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-25",9,7.42,2246.52,,0.005,0.001,897.016,0.059,0.045,0.0084,15094.884,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-26",9,8.02,2464.13,,0.005,0.001,976.057,0.059,0.048,0.0189,16425.253,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-27",13,11.2,3528.55,,0.007,0.001,1395.54,0.059,0.065,0.0193,23480.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-28",13,12.15,3327,,0.007,0.001,1346.15,0.059,0.062,0.0105,22650.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-29",13,10.63,3303.22,,0.007,0.001,1314.533,0.059,0.066,0.0155,22120.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-30",13,11.72,3692.34,,0.007,0.001,1461.085,0.0591,0.071,0.0108,24582.374,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-07-31",13,12.03,3718.29,,0.007,0.001,1479.067,0.059,0.07,0.013,24885.77,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-01",10,9.55,2938.05,,0.006,0.001,1170.235,0.059,0.058,0.0068,19693.07,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-02",9,8.24,2543.52,,0.005,0.001,1012.6,0.059,0.052,0.0077,17037.536,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-03",8,7.05,2130.09,,0.004,0.001,853.183,0.059,0.044,0.0164,14356.069,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-04",8,7.07,2128.17,,0.004,0.001,853.491,0.059,0.043,0.0171,14360.334,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-06",10,9.2,2531.2,,0.005,0.001,1033.02,0.059,0.05,0.0204,17381.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-07",15,13.39,3345.57,,0.007,0.001,1381.998,0.059,0.068,0.0121,23250.949,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-08",8,7.32,2188.08,,0.004,0.001,876.628,0.059,0.046,0.0083,14751.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-09",9,8.35,2268.43,,0.005,0.001,926.469,0.059,0.049,0.0073,15589.898,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-10",9,8.12,2536.94,,0.005,0.001,1008.002,0.059,0.051,0.0077,16964.844,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-11",10,9.14,2844.28,,0.006,0.001,1130.17,0.059,0.056,0.0076,19018.006,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-12",11,10.35,3287.75,,0.007,0.001,1299.78,0.059,0.063,0.0065,21870.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-13",12,11.52,3707.44,,0.007,0.001,1465.448,0.059,0.071,0.0066,24659.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-14",20,19.53,5899.16,,0.012,0.001,2330.638,0.059,0.104,0.0062,39215.182,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-15",15,13.3,4104.69,,0.008,0.001,1622.86,0.059,0.077,0.0101,27309.809,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-16",19,17.68,4434.21,,0.009,0.001,1807.028,0.059,0.082,0.0113,30409.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-17",18,16.9,5003.45,,0.01,0.001,1985.625,0.059,0.09,0.0067,33413.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-18",20,19.2,5082.55,,0.01,0.001,2055.02,0.059,0.093,0.0062,34580.705,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-19",16,15.65,4519.9,,0.009,0.001,1801.98,0.059,0.079,0.0058,30321.385,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-20",23,22.07,5809.52,,0.012,0.001,2325.134,0.059,0.098,0.0077,39123.195,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-21",14,13.65,4283.15,,0.009,0.001,1690,0.059,0.077,0.0061,28437.91,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-22",14,12.79,3843,,0.008,0.001,1532.992,0.059,0.074,0.007,25795.996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-23",12,10.94,3468.5,,0.007,0.001,1372.754,0.059,0.064,0.007,23096.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-24",13,11.88,3787.44,,0.008,0.001,1493.898,0.059,0.07,0.0074,25137.527,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-25",13,11.99,3807.61,,0.008,0.001,1504.423,0.059,0.07,0.0073,25313.087,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-26",18,16.9,5280.14,,0.011,0.001,2080.508,0.059,0.1,0.0091,35006.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-27",17,16.38,4240.54,,0.009,0.001,1711.476,0.059,0.081,0.0063,28799.448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-28",11,10.15,3158.21,,0.006,0.001,1254.796,0.059,0.061,0.0074,21114.661,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-29",8,6.4,1492.3,,0.003,0.001,631.434,0.059,0.037,0.0226,10624.241,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-30",8,6.88,2062.68,,0.004,0.001,828.68,0.059,0.042,0.0153,13944.212,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-08-31",8,6.9,2084.08,,0.004,0.001,831.504,0.059,0.044,0.0143,13992.126,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-01",13,11.7,2890.4,,0.006,0.001,1204.23,0.059,0.058,0.0144,20263.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-02",8,7.39,2271.99,,0.005,0.001,917.081,0.059,0.048,0.0076,15433.302,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-03",18,17.13,4131.47,,0.009,0.001,1713.781,0.059,0.083,0.0067,28839.738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-04",19,17.87,4443.74,,0.009,0.001,1836.724,0.059,0.084,0.0094,30904.883,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-05",17,16.39,4346.91,,0.009,0.001,1781.977,0.059,0.078,0.0054,29984.035,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-06",17,16.62,4679.04,,0.01,0.001,1888.182,0.059,0.082,0.0053,31775.452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-07",16,14.65,3650.74,,0.008,0.001,1498.97,0.059,0.069,0.0103,25222.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-08",12,10.67,1910.28,,0.004,0.001,838.08,0.059,0.041,0.0145,14102.756,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-09",10,8.7,2578.78,,0.005,0.001,1041.937,0.059,0.05,0.012,17531.275,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-10",10,8.5,2712.56,,0.005,0.001,1080.649,0.059,0.052,0.0131,18185.708,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-11",13,12.25,3070.75,,0.006,0.001,1285,0.059,0.063,0.0108,21623.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-12",12,10.68,3123.75,,0.006,0.001,1264.028,0.059,0.06,0.0148,21272.685,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-13",9,6.99,2135.45,,0.004,0.001,861.268,0.0591,0.045,0.0191,14491.611,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-14",12,10.7,3431.24,,0.007,0.001,1370.637,0.059,0.064,0.0111,23064.089,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-15",9,8.2,2568.33,,0.005,0.001,1032.095,0.059,0.051,0.0074,17366.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-16",12,10.94,3526.74,,0.007,0.001,1417.236,0.059,0.068,0.0076,23848.242,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-17",11,10.2,3225.33,,0.007,0.001,1292.074,0.059,0.063,0.0072,21743.005,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-18",10,9.46,2970.84,,0.006,0.001,1190.909,0.059,0.059,0.0073,20037.271,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-19",9,8.2,2551.49,,0.005,0.001,1023.775,0.059,0.052,0.0079,17227.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-20",10,8.94,2825.7,,0.006,0.001,1121.434,0.059,0.055,0.0077,18872.902,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-21",13,12.58,3852.44,,0.008,0.001,1533.228,0.059,0.07,0.0067,25797.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-22",19,17.27,4351,,0.009,0.001,1802.482,0.0591,0.088,0.0096,30329.212,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-23",10,8.87,2663.19,,0.005,0.001,1067.925,0.059,0.053,0.0162,17970.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-24",12,10.87,3385.98,,0.007,0.001,1355.594,0.059,0.064,0.0134,22809.065,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-25",8,7.14,2162.14,,0.004,0.001,876.638,0.059,0.045,0.008,14752.07,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-26",9,7.2,2059.28,,0.004,0.001,853.924,0.0591,0.044,0.0154,14370.488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-27",8,7.15,2152.56,,0.004,0.001,870,0.059,0.044,0.0079,14638.898,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-28",8,6.15,1813.84,,0.004,0.001,742.72,0.059,0.042,0.0123,12495.462,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-29",13,12.82,3836.36,,0.008,0.001,1545.418,0.059,0.071,0.0061,25999.576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-09-30",15,13.22,3713.03,,0.008,0.001,1511.174,0.059,0.083,0.0125,25427.277,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-01",12,10.81,3410.57,,0.007,0.001,1360.742,0.059,0.064,0.0098,22897.119,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-02",12,10.85,3294.2,,0.007,0.001,1321.07,0.059,0.063,0.012,22229.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-03",13,12.8,3960.4,,0.008,0.001,1579.22,0.059,0.072,0.0061,26575.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-04",20,18.7,4885.38,,0.01,0.001,2003.442,0.059,0.095,0.0065,33712.684,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-05",20,19.52,6015.96,,0.012,0.001,2388.92,0.059,0.106,0.0063,40194.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-06",13,10.97,3499.6,,0.007,0.001,1391.186,0.059,0.067,0.0139,23409.423,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-07",8,7.19,2217.26,,0.004,0.001,890.332,0.059,0.045,0.0075,14983.541,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-08",8,7.19,2093.52,,0.004,0.001,853.704,0.059,0.05,0.0098,14364.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-09",11,9.94,3136.75,,0.006,0.001,1244.724,0.059,0.059,0.0107,20943.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-10",8,7.13,2174.72,,0.004,0.001,869.295,0.059,0.044,0.0081,14627.177,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-11",8,7.17,2225.51,,0.004,0.001,890.774,0.059,0.044,0.0073,14990.278,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-12",12,11.6,3592,,0.007,0.001,1427.48,0.059,0.065,0.0065,24019.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-13",13,11.1,2754.38,,0.006,0.001,1135.07,0.059,0.058,0.0093,19099.006,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-14",10,8.92,2820.83,,0.006,0.001,1118.964,0.059,0.055,0.0121,18830.81,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-15",12,11.17,3519.88,,0.007,0.001,1398.461,0.059,0.068,0.0071,23529.922,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-16",16,14.63,4295,,0.009,0.001,1707.039,0.059,0.078,0.0079,28724.538,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-17",9,7.9,2426.06,,0.005,0.001,968.824,0.059,0.047,0.0112,16302.441,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-18",8,7.41,2252.59,,0.005,0.001,899.78,0.059,0.046,0.007,15141.259,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-19",10,8.1,2442,,0.005,0.001,982.065,0.0592,0.049,0.0132,16524.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-20",21,19.7,4980.52,,0.011,0.001,2102.81,0.059,0.095,0.0091,35381.791,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-21",10,8.1,2488.8,,0.005,0.001,1000.428,0.059,0.051,0.0112,16832.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-22",9,7.38,2250.37,,0.005,0.001,907.032,0.059,0.05,0.0077,15262.453,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-23",18,17.13,5102.38,,0.01,0.001,2020.172,0.059,0.093,0.0064,33991.051,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-24",16,14.54,4195.3,,0.009,0.001,1692.15,0.059,0.088,0.0102,28473.221,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-25",10,9.07,2875,,0.006,0.001,1148.806,0.059,0.059,0.0068,19327.125,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-26",18,15.39,4642.29,,0.009,0.001,1866.377,0.059,0.098,0.0129,31406.088,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-27",17,14.47,4030.2,,0.008,0.001,1638.206,0.059,0.086,0.0133,27562.131,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-28",17,14.26,4011.92,,0.008,0.001,1634.59,0.059,0.085,0.0168,27500.252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-29",9,7.35,2236.28,,0.005,0.001,903.58,0.059,0.048,0.007,15204.752,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-30",18,17.37,4705.91,,0.01,0.001,1908.777,0.059,0.088,0.006,32119.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-10-31",10,9.05,2762,,0.006,0.001,1103.865,0.059,0.058,0.0061,18574.255,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-01",16,14.66,3859.3,,0.008,0.001,1592.098,0.059,0.08,0.0074,26790.786,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-02",12,11.88,3901.32,,0.008,0.001,1554.864,0.059,0.072,0.006,26166.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-03",11,9.26,2243.08,,0.005,0.001,968.022,0.059,0.051,0.0165,16290.235,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-04",10,9.9,3036.1,,0.006,0.001,1229.43,0.059,0.058,0.0062,20686.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-05",18,16.4,4794.92,,0.01,0.001,1949.772,0.059,0.091,0.0129,32808.354,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-06",9,7.01,2141.27,,0.004,0.001,872.898,0.059,0.046,0.0209,14687.684,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-08",8,7.35,1643.68,,0.004,0.001,710.916,0.059,0.04,0.0088,11962.031,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-09",8,7.19,2237.51,,0.005,0.001,903.572,0.059,0.047,0.0083,15202.979,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-10",16,13.96,3849.04,,0.008,0.001,1585.583,0.059,0.084,0.0114,26681.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-11",9,7.9,2314.85,,0.005,0.001,940.35,0.059,0.047,0.0173,15821.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-12",8,7.18,2214.42,,0.005,0.001,895.011,0.059,0.046,0.0079,15061.197,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-14",8,7,2139.73,,0.004,0.001,871.519,0.059,0.045,0.0149,14664.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-15",9,7.92,1983,,0.004,0.001,824.733,0.059,0.043,0.017,13878.238,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-16",11,10.05,2712,,0.006,0.001,1123.715,0.059,0.064,0.0066,18907.395,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-17",11,8.17,2363.25,,0.005,0.001,965.265,0.059,0.05,0.023,16240.863,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-18",16,14.87,4027.63,,0.008,0.001,1672.123,0.059,0.078,0.0071,28133.789,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-19",9,7.12,2181.29,,0.004,0.001,883.098,0.0591,0.046,0.0126,14859.435,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-20",13,11.89,3396.89,,0.007,0.001,1380.594,0.059,0.066,0.0122,23230.571,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-23",9,7.37,1218.72,,0.003,0.001,563.134,0.059,0.033,0.0224,9474.799,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-24",9,7.64,2288.69,,0.005,0.001,933.776,0.0591,0.049,0.0072,15710.859,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-25",9,7.37,1754.64,,0.004,0.001,742.975,0.059,0.04,0.0193,12501.378,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-27",10,9.25,2522.25,,0.005,0.001,1042.325,0.059,0.054,0.0172,17540.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-28",8,7.05,1124.6,,0.003,0.001,511.745,0.059,0.022,0.0119,8612.235,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-29",10,9.03,2665,,0.005,0.001,1085.966,0.059,0.056,0.0063,18273.422,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-11-30",21,19,4623.95,,0.01,0.001,1933.54,0.059,0.09,0.013,32538.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-01",10,8.63,2483.38,,0.005,0.001,1023.695,0.059,0.055,0.0069,17225.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-02",18,17.02,4797.95,,0.01,0.001,1965.978,0.059,0.09,0.0099,33082.018,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-03",9,7.4,2223.3,,0.005,0.0009,913.92,0.0591,0.052,0.008,15378.135,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-04",10,8.12,2445.59,,0.005,0.001,1002.942,0.0592,0.053,0.0156,16875.719,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-13",7,5.59,1014.17,,0.002,0.001,462.819,0.059,0.042,0.026,7787.482,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-14",8,7.75,2435,,0.005,0.001,981.025,0.059,0.049,0.0071,16510.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-15",20,18.91,4588.82,,0.01,0.001,1966.124,0.059,0.085,0.0081,33081.626,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-16",20,16.98,4227.55,,0.009,0.001,1795.097,0.0591,0.094,0.0151,30205.442,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-17",17,15.88,4159.08,,0.009,0.001,1723.872,0.059,0.081,0.0096,29008.756,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-18",14,12.7,3826.35,,0.008,0.001,1548.84,0.059,0.073,0.0136,26062.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-19",8,6.88,2013.09,,0.004,0.001,836.625,0.059,0.046,0.01,14078.53,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-20",8,6.92,2115.69,,0.004,0.001,865.947,0.059,0.044,0.0159,14572.339,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-21",10,9.02,2508.3,,0.005,0.001,1036.703,0.059,0.051,0.0126,17443.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-22",9,7.68,2264.85,,0.005,0.001,932.07,0.059,0.046,0.0193,15684.641,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-23",17,15.13,3502.67,,0.008,0.001,1492.393,0.059,0.069,0.0162,25116.556,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-24",8,6.94,2159,,0.004,0.001,882.69,0.059,0.047,0.0094,14852.43,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-25",8,6.93,995.73,,0.002,0.001,482.137,0.059,0.029,0.0196,8113.322,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-27",8,6.88,2066.6,,0.004,0.001,852.028,0.059,0.046,0.0149,14336.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-28",10,8.1,2365.75,,0.005,0.001,975.245,0.0591,0.05,0.0126,16412.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-29",9,7.12,2154.43,,0.004,0.0009,885.099,0.0591,0.047,0.0113,14894.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-30",9,7.15,2163.9,,0.004,0.001,886.03,0.059,0.047,0.0117,14909.195,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Alamitos",315,"CT2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-06",8,7.13,1088.33,,0.004,0.001,726.897,0.059,0.039,0.007,12229.879,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-07",19,17.55,3206.14,,0.008,0.001,1627.146,0.059,0.056,0.0048,27381.104,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-08",17,16.23,3228.91,,0.008,0.001,1608.7,0.059,0.049,0.0058,27072.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-09",16,13.89,2052,,0.006,0.001,1108.229,0.059,0.043,0.0053,18650.915,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-10",8,7.28,1107.28,,0.004,0.001,741.268,0.059,0.031,0.0101,12473.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-11",9,8.13,1246.05,,0.004,0.001,828.229,0.059,0.021,0.0037,13935.546,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-06",8,6.5,975.94,,0.003,0.001,654.469,0.059,0.038,0.0218,11011.852,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-25",9,6.42,909.46,,0.003,0.001,556.632,0.059,0.037,0.0139,9365.742,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-26",3,2.54,375.06,,0.001,0.001,253.87,0.059,0.019,0.009,4272.642,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-24",6,4.62,629.46,,0.002,0.001,369.838,0.059,0.025,0.0125,6222.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-13",1,0.02,0,,0,0.001,0.282,0.059,0,0,4.742,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-24",1,0.05,0,,0,0.001,1.055,0.06,0,0.045,17.73,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-04-30",8,7.57,1716.17,,0.004,0.001,847.757,0.059,0.036,0.0088,14263.814,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-01",2,1.63,415.01,,0.001,0.001,196.441,0.059,0.005,0.003,3305.623,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-04",9,7.84,1660.04,,0.004,0.001,836.179,0.059,0.03,0.0069,14071.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-05",5,3.55,539.7,,0.002,0.001,359.514,0.059,0.021,0.0168,6050.017,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-12",3,2.75,394.39,,0.001,0.001,267.932,0.059,0.026,0.0137,4509.139,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-13",9,8.13,1948.34,,0.005,0.001,939.213,0.059,0.036,0.0158,15805.637,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-14",2,1.25,313,,0.001,0.001,148.825,0.059,0.004,0.003,2503.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-19",9,7.8,1147.52,,0.003,0.001,625.348,0.059,0.032,0.0077,10521.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-20",18,17.12,3831.96,,0.009,0.001,1858.744,0.059,0.064,0.0044,31275.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-26",4,2.99,430.16,,0.001,0.001,293.516,0.059,0.023,0.0245,4937.227,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-29",5,4.36,712.65,,0.002,0.001,381.162,0.059,0.021,0.0082,6414.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-30",5,4.25,636.35,,0.002,0.001,431.248,0.059,0.027,0.0204,7255.935,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-01",7,6.6,1214.56,,0.003,0.001,622,0.059,0.027,0.0066,10465.444,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-02",4,3.12,455.4,,0.002,0.001,305.587,0.059,0.01,0.005,5142.201,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-03",3,2.31,343.82,,0.001,0.001,229.335,0.059,0.02,0.0113,3859.156,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-04",9,8.11,1277.19,,0.003,0.001,668.973,0.059,0.027,0.0058,11254.718,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-09",10,9.6,1994.18,,0.005,0.001,983.762,0.059,0.034,0.0045,16555.89,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-10",12,10.94,2290.96,,0.006,0.001,1122.672,0.059,0.035,0.0044,18891.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-11",10,9.69,1819.44,,0.005,0.001,913.535,0.059,0.031,0.0046,15374.761,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-09",4,3.1,413.32,,0.001,0.001,241.462,0.059,0.016,0.0078,4062.956,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-10",6,3.44,384.38,,0.001,0.001,239.255,0.0592,0.021,0.021,4025.149,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-11",14,11.22,2158.86,,0.006,0.001,1151.41,0.0591,0.046,0.0123,19372.884,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-12",11,10.6,2315.48,,0.006,0.001,1128.336,0.059,0.038,0.0049,18985.528,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-14",6,4.95,711.26,,0.002,0.001,390.871,0.059,0.019,0.0068,6579.695,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-15",5,3.86,543.54,,0.002,0.001,301.91,0.059,0.016,0.008,5079.831,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-17",4,2.84,390.6,,0.001,0.001,223.512,0.059,0.015,0.0093,3760.004,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-20",6,4.92,657.08,,0.002,0.001,378.526,0.059,0.028,0.0088,6371.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-21",21,20.62,3610.48,,0.009,0.001,1812.02,0.059,0.04,0.0026,30491.442,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-27",11,10.53,2153.29,,0.005,0.001,1063.435,0.059,0.037,0.0047,17896.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-28",4,2.86,389.96,,0.001,0.001,221.442,0.059,0.016,0.0103,3724.683,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-29",4,2.86,443.55,,0.001,0.001,241.857,0.059,0.019,0.0103,4069.567,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-30",11,8.96,1456.54,,0.004,0.001,794.655,0.059,0.035,0.0063,13370.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-07-31",22,21.88,4306.28,,0.011,0.001,2111.096,0.059,0.052,0.0029,35519.472,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-01",4,2.94,404,,0.001,0.001,229.542,0.059,0.013,0.008,3863.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-02",4,2.95,405.72,,0.001,0.001,229.88,0.059,0.013,0.0078,3868.748,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-03",9,7.94,1478.26,,0.004,0.001,745.778,0.059,0.028,0.0056,12548.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-12",12,11.85,2430.18,,0.006,0.001,1200.293,0.059,0.041,0.0045,20196.964,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-13",8,6.61,1443.1,,0.004,0.001,709.04,0.059,0.028,0.0084,11929.468,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-14",11,10.35,2391.74,,0.006,0.001,1150.974,0.059,0.038,0.0043,19368.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-15",9,7.6,1459.14,,0.004,0.001,731.298,0.059,0.027,0.0131,12304.331,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-16",5,4.42,629.86,,0.002,0.001,344.563,0.059,0.017,0.0086,5798.301,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-17",14,13.22,2747.56,,0.007,0.001,1344.264,0.059,0.044,0.0105,22622.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-18",17,15.31,3586.25,,0.009,0.001,1718.667,0.059,0.051,0.0042,28923.105,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-19",11,10.98,2288.64,,0.006,0.001,1122.768,0.059,0.036,0.0042,18893.018,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-20",20,19.62,3684,,0.009,0.001,1823.614,0.059,0.041,0.0027,30683.772,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-21",14,12.4,2566.6,,0.006,0.001,1275.579,0.059,0.041,0.0051,21463.991,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-22",11,10.69,2144.2,,0.005,0.001,1067.027,0.059,0.031,0.004,17954.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-24",8,6.86,1521.72,,0.004,0.001,750.12,0.059,0.028,0.0073,12623.456,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-25",1,0.88,103.84,,0,0.001,76.208,0.059,0.014,0.022,1281.896,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-26",9,8.59,1678.97,,0.004,0.001,841.37,0.059,0.025,0.0043,14157.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-27",7,6.35,1390.6,,0.003,0.001,686.607,0.059,0.027,0.0083,11554.689,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-28",4,2.55,380.52,,0.001,0.001,254.541,0.059,0.019,0.0238,4282.808,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-01",5,3.37,631.23,,0.002,0.001,362.177,0.059,0.025,0.0154,6095.381,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-03",10,9.11,1852.16,,0.005,0.001,922.458,0.059,0.031,0.0046,15521.263,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-04",7,6.19,1267.06,,0.003,0.001,633.192,0.059,0.025,0.0069,10655.473,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-05",9,8.2,1795.62,,0.004,0.001,880.372,0.059,0.031,0.006,14812.036,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-06",11,9.89,1923.76,,0.005,0.001,1027.432,0.059,0.034,0.0035,17289.071,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-08",15,13.84,2160.62,,0.007,0.001,1431.728,0.059,0.048,0.005,24091.232,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-09",4,2.95,399.2,,0.001,0.001,229.991,0.059,0.015,0.0095,3869.559,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-10",5,3.02,404.34,,0.001,0.001,231.515,0.059,0.015,0.014,3895.626,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-11",21,19.22,2981.02,,0.009,0.001,1845.103,0.059,0.057,0.0039,31045.291,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-12",12,11.73,2770.43,,0.007,0.001,1327.533,0.059,0.044,0.0049,22338.674,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-13",23,22.6,4804.94,,0.012,0.001,2324.763,0.059,0.057,0.0029,39119.137,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-14",22,21.62,4053.34,,0.01,0.001,2005.34,0.059,0.048,0.0028,33742.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-15",5,3.94,587.66,,0.002,0.001,395.104,0.059,0.023,0.0188,6648.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-16",12,10.85,2238.91,,0.006,0.001,1103.595,0.059,0.036,0.0049,18569.213,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-17",2,0.35,34.25,,0,0.001,26.439,0.059,0.011,0.048,444.915,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-18",14,13.97,3108.88,,0.008,0.001,1510.138,0.059,0.046,0.0039,25413.036,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-19",9,8.06,1742.08,,0.004,0.001,854.098,0.059,0.031,0.0063,14372.182,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-20",11,10.6,2401.78,,0.006,0.001,1174.312,0.059,0.039,0.0049,19760.498,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-21",20,18.96,3356.01,,0.009,0.001,1698.845,0.059,0.041,0.0031,28584.679,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-24",7,6.73,1342.78,,0.003,0.001,672.768,0.059,0.024,0.0057,11319.823,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-25",8,6.71,1466.92,,0.004,0.001,722.207,0.059,0.028,0.0061,12152.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-27",4,2.81,455.15,,0.001,0.001,247.911,0.059,0.017,0.0098,4170.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-28",5,4.43,606.55,,0.002,0.001,389.527,0.059,0.027,0.0092,6555.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-29",8,5.69,1064.92,,0.003,0.001,545.305,0.059,0.023,0.008,9175.078,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-09-30",9,8.61,1573.84,,0.004,0.001,796.773,0.059,0.026,0.0049,13407.251,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-01",8,6.48,1229.64,,0.003,0.001,624.257,0.059,0.024,0.0098,10503.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-02",5,4.04,784.16,,0.002,0.001,399.166,0.059,0.019,0.011,6717.594,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-03",14,13.67,3222.97,,0.008,0.001,1544.811,0.059,0.047,0.0045,25995.911,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-04",24,24,5205,,0.013,0.001,2504.6,0.059,0.061,0.0029,42146.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-05",24,22.85,4581.61,,0.011,0.001,2251.706,0.059,0.054,0.0029,37890.578,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-06",21,20.6,4165.8,,0.01,0.001,2040.82,0.059,0.051,0.0029,34342.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-07",8,7.61,1645.59,,0.004,0.001,804.459,0.059,0.031,0.0051,13537.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-08",3,2.51,354.4,,0.001,0.001,241.959,0.059,0.022,0.0127,4071.355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-11",8,6.44,1009.21,,0.003,0.001,548.727,0.0591,0.022,0.0046,9235.351,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-12",21,17.77,3356.9,,0.009,0.001,1693.023,0.059,0.041,0.0031,28488.351,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-13",14,12.16,1988.74,,0.005,0.001,1042.013,0.059,0.037,0.0055,17533.707,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-14",5,4.09,758.8,,0.002,0.001,393.36,0.059,0.018,0.0094,6621.018,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-15",13,11.53,2113.59,,0.006,0.001,1143.613,0.059,0.035,0.0038,19244.145,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-16",8,6.28,1141.4,,0.003,0.001,587.002,0.059,0.02,0.004,9878.226,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-17",7,5.85,932.17,,0.002,0.001,493.336,0.059,0.022,0.0174,8303.487,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-18",11,10.1,2292.56,,0.006,0.001,1112.84,0.059,0.038,0.0063,18725.562,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-19",14,13.1,2445.06,,0.006,0.001,1219.688,0.059,0.036,0.0041,20525.493,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-20",15,14.38,3063.22,,0.008,0.001,1490.014,0.059,0.062,0.0054,25072.248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-01",11,9.78,1984.46,,0.005,0.001,1002.216,0.059,0.037,0.0058,16863.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-02",10,8.71,1664.48,,0.004,0.001,837.838,0.059,0.03,0.0053,14095.987,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-03",10,9.11,1898.95,,0.005,0.001,940.357,0.059,0.033,0.0053,15822.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-04",8,7.1,1567.1,,0.004,0.001,771.752,0.059,0.031,0.0085,12986.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-05",13,11.22,2329.5,,0.006,0.001,1161.383,0.059,0.042,0.0055,19542.827,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-06",7,6.1,1161.14,,0.003,0.001,588.17,0.059,0.026,0.0091,9895.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-15",3,2.4,347.16,,0.001,0.001,234.945,0.059,0.022,0.0127,3952.281,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-16",9,7.85,1252.58,,0.003,0.001,659.156,0.059,0.025,0.006,11090.692,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-17",15,13.85,2396.03,,0.006,0.001,1234.349,0.059,0.043,0.0053,20771.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-19",8,7.43,1159.6,,0.004,0.001,763.223,0.059,0.033,0.0081,12841.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-20",1,0.27,19.98,,0,0.001,18.441,0.059,0.002,0.012,310.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-06",3,2.21,306.4,,0.001,0.001,183.673,0.059,0.034,0.0183,3090.679,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-13",9,7.93,1629.11,,0.004,0.001,826.903,0.059,0.035,0.0056,13913.311,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-16",8,7.5,1595.36,,0.004,0.001,796.984,0.059,0.034,0.0074,13409.877,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"5",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-06",8,7.6,1359.46,,0.003,0.001,691.462,0.059,0.035,0.0065,11635.852,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-07",9,7.85,1594.77,,0.004,0.001,781.898,0.059,0.038,0.0079,13154.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-08",17,15.73,2975.26,,0.007,0.001,1465.987,0.059,0.059,0.008,24668.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-09",17,15.14,2262.93,,0.006,0.001,1198.16,0.059,0.057,0.0066,20161.417,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-10",8,7.23,1106.7,,0.004,0.001,728.437,0.059,0.037,0.013,12257.931,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-11",7,6.1,938.8,,0.003,0.001,614.69,0.059,0.02,0.007,10342.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-06",8,6.5,1302.28,,0.003,0.001,660.486,0.059,0.046,0.0164,11112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-07",16,12.19,1836.03,,0.005,0.001,1054.128,0.059,0.058,0.0158,17737.412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-08",8,4.74,686.76,,0.002,0.001,458.818,0.059,0.03,0.0193,7720.954,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-26",1,0.65,81.25,,0,0.001,57.85,0.059,0.016,0.033,973.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-28",3,2.45,347.64,,0.001,0.001,237.456,0.059,0.017,0.0097,3995.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-02-29",6,4.85,707.37,,0.002,0.001,385.477,0.059,0.026,0.0103,6484.144,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-25",6,2.19,236.32,,0.001,0.001,158.388,0.0592,0.045,0.0428,2665.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-13",9,8.97,1939.88,,0.005,0.001,943.296,0.059,0.045,0.0064,15871.143,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-14",6,4.9,1022.34,,0.003,0.001,537.888,0.059,0.027,0.013,9051.207,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-20",4,3.7,530.2,,0.001,0.001,295.496,0.059,0.022,0.0103,4970.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-23",1,0.07,0,,0,0.001,1.505,0.059,0,0.024,25.319,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-04-30",9,8.1,1797.3,,0.004,0.001,870.97,0.059,0.039,0.0076,14659.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-01",2,1.63,416.01,,0.001,0.001,192.781,0.059,0.006,0.004,3243.611,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-13",8,7.97,1921.76,,0.005,0.001,908.426,0.059,0.047,0.0074,15282.456,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-14",6,5.88,1161.28,,0.003,0.001,561.988,0.059,0.016,0.0032,9456.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-21",9,7.9,1156.25,,0.003,0.001,614.091,0.059,0.039,0.0092,10333.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-22",13,12.13,2701.24,,0.006,0.001,1286.687,0.059,0.085,0.0105,21646.394,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-29",5,4.61,751.11,,0.002,0.001,392.938,0.059,0.029,0.011,6610.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-30",6,4.74,705.72,,0.002,0.001,469.451,0.059,0.035,0.0207,7900.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-02",8,5.94,874.71,,0.002,0.001,477.28,0.059,0.039,0.0114,8030.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-03",7,6.11,975.85,,0.003,0.001,563.934,0.059,0.032,0.0079,9488.305,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-04",9,8.59,1335.95,,0.003,0.001,687.68,0.059,0.034,0.0069,11573.158,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-09",15,13.29,2467.27,,0.006,0.001,1221.997,0.059,0.054,0.0065,20563.994,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-10",12,11.17,2295.18,,0.006,0.001,1103.656,0.059,0.041,0.005,18570.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-11",10,9.45,1761.86,,0.004,0.001,868.255,0.059,0.037,0.0056,14609.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-23",10,9.36,1833.84,,0.005,0.001,901.892,0.059,0.042,0.006,15175.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-07",5,4.08,581.72,,0.002,0.001,320.175,0.059,0.019,0.0092,5387.653,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-08",10,8.93,1688.13,,0.004,0.001,836.241,0.059,0.037,0.0068,14071.798,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-09",10,8.54,1269.94,,0.003,0.001,672.82,0.059,0.041,0.0099,11320.939,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-10",18,16.54,2518.68,,0.007,0.001,1358.664,0.059,0.053,0.0058,22867.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-11",11,10.6,2372,,0.006,0.001,1128.6,0.059,0.048,0.0063,18990.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-12",8,5.47,780.92,,0.003,0.001,521.371,0.059,0.043,0.025,8772.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-13",3,2.4,349,,0.001,0.001,231.196,0.059,0.02,0.0157,3890.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-14",9,6.95,966.25,,0.003,0.001,532.24,0.059,0.037,0.0103,8957.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-15",5,3.85,547.83,,0.001,0.001,296.521,0.059,0.02,0.0104,4988.894,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-16",11,9.66,1672.52,,0.004,0.001,846.049,0.059,0.04,0.007,14237.899,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-17",5,3.85,546.38,,0.001,0.001,295.46,0.059,0.022,0.0116,4971.242,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-18",8,7.6,1517.9,,0.004,0.001,741.906,0.059,0.037,0.0075,12484.801,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-19",9,7.43,1055.96,,0.003,0.001,572.301,0.059,0.038,0.0097,9630.258,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-20",6,4.58,612.08,,0.002,0.001,344.945,0.059,0.033,0.0137,5805.721,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-21",21,18.4,3181.14,,0.008,0.001,1589.05,0.059,0.051,0.005,26736.102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-27",12,11.41,2262.57,,0.006,0.001,1109.591,0.059,0.053,0.0066,18671.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-28",18,16.85,2536.08,,0.007,0.001,1311.807,0.059,0.054,0.0057,22076.309,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-29",21,20.63,3691.22,,0.009,0.001,1806.572,0.059,0.058,0.0038,30397.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-30",11,9.59,1747.66,,0.005,0.001,894.286,0.059,0.052,0.0086,15043.971,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-07-31",22,20.85,4104.65,,0.01,0.001,1979.231,0.059,0.074,0.0052,33306.755,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-01",9,7.05,978.74,,0.003,0.001,536.74,0.059,0.04,0.0107,9032.345,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-02",8,5.75,783.29,,0.002,0.001,436.633,0.059,0.038,0.013,7347.113,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-03",10,8.95,1646.74,,0.004,0.001,813.005,0.059,0.039,0.0076,13681.147,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-04",6,5.34,997.36,,0.003,0.001,497.94,0.059,0.026,0.0078,8380.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-12",11,10.4,1987.6,,0.005,0.001,1031.66,0.059,0.049,0.0092,17359.98,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-13",22,21.42,3961.06,,0.01,0.001,1922.444,0.059,0.06,0.0037,32349.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-14",12,10.4,2373.82,,0.006,0.001,1118.663,0.0591,0.05,0.0053,18822.593,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-15",8,7.35,1545.45,,0.004,0.001,743.851,0.059,0.035,0.0094,12519.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-16",5,4.52,645.66,,0.002,0.001,345.753,0.059,0.022,0.0096,5818.575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-17",14,12.57,2597.4,,0.006,0.001,1252.831,0.059,0.051,0.0074,21082.713,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-18",24,23.12,4833.96,,0.012,0.001,2290.524,0.059,0.069,0.0038,38543.916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-19",14,13.73,2871.62,,0.007,0.001,1368.254,0.059,0.05,0.0051,23021.074,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-20",20,19.88,3713.12,,0.009,0.001,1792.748,0.059,0.054,0.0035,30167.684,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-21",14,12.44,2564.49,,0.006,0.001,1240.635,0.059,0.046,0.0054,20875.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-22",13,11.85,2314.5,,0.006,0.001,1123.769,0.059,0.039,0.005,18910.242,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-23",11,10.36,2295.81,,0.005,0.001,1087.995,0.059,0.044,0.0058,18308.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-24",8,7.61,1700.48,,0.004,0.001,810.953,0.059,0.035,0.0056,13646.847,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-25",4,2.74,393.84,,0.001,0.001,262.998,0.059,0.021,0.0243,4424.308,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-27",7,6.35,1393.22,,0.003,0.001,671.555,0.059,0.03,0.0089,11299.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-28",4,3.1,462.19,,0.002,0.001,304.944,0.059,0.026,0.011,5130.824,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-29",4,2.93,397.06,,0.001,0.001,222.876,0.059,0.017,0.011,3751.559,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-01",4,3.12,565.23,,0.002,0.001,324.45,0.059,0.025,0.0195,5460.248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-03",5,3.78,695.2,,0.002,0.001,355.104,0.059,0.022,0.0106,5975.607,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-04",7,6.19,1272.59,,0.003,0.001,620.965,0.059,0.031,0.0083,10448.148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-05",8,7.44,1610.83,,0.004,0.001,771.634,0.059,0.036,0.008,12985.172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-06",10,8.8,1904.22,,0.005,0.001,914.942,0.059,0.038,0.0085,15394.804,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-08",12,9.78,1457.02,,0.005,0.001,915.868,0.059,0.048,0.0087,15411.069,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-09",4,3.73,527.89,,0.001,0.001,285.089,0.059,0.023,0.012,4795.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-10",9,6.61,913.21,,0.003,0.001,503.99,0.059,0.039,0.0118,8480.601,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-11",18,16.68,2759.7,,0.007,0.001,1395.249,0.059,0.073,0.0073,23478.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-12",17,16.26,3425.87,,0.008,0.001,1652.751,0.059,0.067,0.0056,27809.251,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-13",24,23.72,5203.4,,0.012,0.001,2446.504,0.059,0.087,0.0045,41166.396,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-14",22,21.62,4076.82,,0.01,0.001,1966.054,0.059,0.061,0.0037,33082.678,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-15",5,3.94,588.71,,0.002,0.001,390.332,0.059,0.029,0.022,6568.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-16",11,10.09,2102.06,,0.005,0.001,1013.305,0.059,0.043,0.0061,17051.587,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-17",11,10.63,2385.03,,0.006,0.001,1129.011,0.059,0.05,0.0065,18997.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-18",14,13.97,3032.7,,0.007,0.001,1438.88,0.059,0.056,0.005,24212.259,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-19",14,13.06,2833.93,,0.007,0.001,1348.956,0.059,0.055,0.0064,22699.817,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-20",4,3.48,590.88,,0.002,0.001,304.98,0.059,0.023,0.016,5131.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-21",20,18.96,3428.53,,0.009,0.001,1689.419,0.059,0.055,0.0043,28425.776,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-24",13,11.94,2497.2,,0.006,0.001,1193.554,0.059,0.05,0.0062,20083.772,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-25",9,8.6,1871.12,,0.005,0.001,892.904,0.059,0.039,0.0066,15023.956,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-27",4,2.81,430.73,,0.001,0.001,233.117,0.059,0.02,0.0138,3922.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-28",5,4.34,601.19,,0.002,0.001,377.006,0.059,0.037,0.013,6342.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-29",20,18.18,3167.24,,0.008,0.001,1575.372,0.059,0.048,0.0041,26510.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-09-30",12,10.85,1985.16,,0.005,0.001,977.378,0.059,0.036,0.0053,16449.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-01",11,10.36,1999.17,,0.005,0.001,979.604,0.059,0.035,0.0052,16483.296,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-02",5,4.25,829.4,,0.002,0.001,412.34,0.059,0.024,0.015,6937.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-03",9,8.42,1960.76,,0.005,0.001,926.372,0.059,0.042,0.0092,15590.794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-04",24,24,5531,,0.013,0.001,2577.4,0.059,0.082,0.0038,43373.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-05",24,22.84,4604.72,,0.011,0.001,2215.444,0.059,0.065,0.0035,37274.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-06",21,20.7,4437.3,,0.011,0.001,2100.48,0.059,0.065,0.0036,35342.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-12",9,8.63,1929.58,,0.005,0.001,924.994,0.059,0.041,0.0066,15565.245,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-13",13,12.36,2419.12,,0.006,0.001,1179.084,0.059,0.047,0.0058,19837.668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-14",6,5.07,1001.23,,0.003,0.001,497.053,0.059,0.025,0.0105,8365.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-15",13,11.45,1996.97,,0.005,0.001,1018.782,0.059,0.038,0.0052,17140.379,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-16",8,6.27,1101.92,,0.003,0.001,556.681,0.059,0.019,0.006,9366.492,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-17",6,5.36,850.79,,0.002,0.001,441.893,0.059,0.021,0.0073,7434.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-19",10,9.58,1760.79,,0.004,0.001,868.127,0.059,0.035,0.0062,14607.682,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-20",6,5.35,877.43,,0.002,0.001,449.215,0.059,0.021,0.0093,7557.681,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-21",18,17.6,3917.14,,0.009,0.001,1848.7,0.059,0.083,0.0055,31106.076,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-22",6,5.6,954.56,,0.002,0.001,482.698,0.059,0.029,0.0075,8122.504,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-01",11,10.98,2417.98,,0.006,0.001,1157.62,0.059,0.053,0.0061,19478.81,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-02",9,8.2,1603.46,,0.004,0.001,788.194,0.059,0.039,0.0074,13264.102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-04",9,8.61,1844.71,,0.004,0.001,888.828,0.059,0.043,0.0074,14956.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-05",11,10.11,2248.7,,0.005,0.001,1069.423,0.059,0.049,0.0069,17993.029,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-16",7,6.36,992.81,,0.003,0.001,518.455,0.059,0.029,0.0083,8724.767,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-17",15,13.85,2406.16,,0.006,0.001,1216.127,0.059,0.058,0.0075,20462.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-01",12,11.35,2161.4,,0.005,0.001,1067.461,0.059,0.054,0.0075,17963.273,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-08",4,2.36,337.35,,0.001,0.001,193.905,0.059,0.028,0.0398,3264.274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-13",8,6.85,1317.79,,0.003,0.001,671.504,0.059,0.046,0.0216,11299.927,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-16",7,6.5,1361.6,,0.003,0.001,668.178,0.059,0.04,0.0107,11240.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-23",9,8.36,1279,,0.003,0.001,671.464,0.059,0.041,0.0076,11298.864,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Segundo",330,"7",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-05",8,8,0,,0,0.001,61.1,0.0595,0.081,0.1403,1027.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-06",24,24,2666,,0.008,0.001,1591.8,0.0591,0.131,0.0082,26788.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-07",21,21,1517,,0.005,0.001,949.5,0.0591,0.035,0.0041,15976,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-26",6,6,0,,0,0.001,31.6,0.062,0.038,0.104,529,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-27",24,24,587,,0.003,0.001,525.3,0.0594,0.154,0.0657,8840,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-28",22,22,1209,,0.004,0.001,804.7,0.0591,0.029,0.0045,13539.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-04",6,6,0,,0,0.001,34.9,0.0567,0.025,0.0948,589.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-06",9,9,0,,0,0.001,58.4,0.0596,0.045,0.0801,980.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-08",10,10,28,,0.001,0.001,111.9,0.0599,0.075,0.0936,1884.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-09",24,24,546,,0.002,0.001,489.4,0.0592,0.021,0.0051,8236.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-10",24,24,903,,0.003,0.001,671.8,0.0591,0.025,0.0046,11306.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-11",24,24,622,,0.003,0.001,521.7,0.0591,0.022,0.005,8779.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-12",24,24,1246,,0.004,0.001,850.3,0.0592,0.038,0.0053,14305.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-13",24,24,1052,,0.004,0.001,741.7,0.059,0.031,0.0049,12479.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-14",24,24,1019,,0.004,0.001,727.5,0.0591,0.025,0.0043,12238.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-15",24,24,770,,0.003,0.001,597.1,0.0592,0.029,0.0058,10048.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-16",24,24,845,,0.003,0.001,638.7,0.0591,0.029,0.0053,10749.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-17",24,24,602,,0.003,0.001,509.7,0.0595,0.025,0.0058,8572.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-18",24,24,707,,0.003,0.001,561.8,0.0592,0.023,0.0049,9454.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-19",24,24,748,,0.003,0.001,586.9,0.0592,0.022,0.0047,9877.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-20",24,24,812,,0.003,0.001,617.3,0.0592,0.028,0.0053,10385.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-21",24,24,1148,,0.004,0.001,793,0.0592,0.048,0.0066,13346.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-22",24,24,853,,0.003,0.001,645,0.0591,0.026,0.0048,10854,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-23",24,24,984,,0.004,0.001,710.9,0.0592,0.026,0.0045,11963.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-24",24,24,807,,0.003,0.001,613.9,0.059,0.025,0.005,10334.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-25",24,24,578,,0.002,0.001,486.4,0.0593,0.021,0.0052,8184,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-26",8,8,39,,0,0.001,90.1,0.0598,0.025,0.053,1516.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-27",24,24,1162,,0.004,0.001,797.8,0.0591,0.032,0.0048,13426.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-28",24,24,861,,0.003,0.001,637.6,0.0593,0.029,0.0053,10727.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-29",11,11,116,,0.001,0.001,150.5,0.0599,0.038,0.0451,2530.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-30",24,24,684,,0.003,0.001,552.5,0.0593,0.022,0.0048,9296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-15",11,11,14,,0.001,0.001,99.4,0.0596,0.115,0.1371,1673.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-16",24,24,1058,,0.004,0.001,753.8,0.0591,0.026,0.0047,12685.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-17",24,24,787,,0.003,0.001,606.5,0.0593,0.022,0.0046,10206.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-18",24,24,575,,0.003,0.001,504.8,0.0595,0.021,0.005,8489.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-19",24,24,901,,0.003,0.001,665.5,0.0592,0.03,0.0054,11198.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-20",7,7,440,,0.001,0.001,285,0.059,0.012,0.005,4796.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-03",10,10,0,,0,0.001,76.9,0.0591,0.114,0.1665,1294.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-04",24,24,1069,,0.004,0.001,776.3,0.0591,0.025,0.0043,13064.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-05",2,2,60,,0,0.001,42.4,0.059,0.002,0.005,713.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-06",23,23,665,,0.003,0.001,548.5,0.0591,0.04,0.0157,9226.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-07",24,24,576,,0.003,0.001,498.4,0.0593,0.025,0.0059,8383.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-08",24,24,1033,,0.004,0.001,740.6,0.0592,0.026,0.0044,12462.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-09",24,24,1484,,0.005,0.001,971.1,0.059,0.038,0.0046,16342.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-20",13,13,35,,0.001,0.001,124.9,0.0602,0.028,0.027,2100.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-21",24,24,1999,,0.006,0.001,1266.6,0.059,0.213,0.0322,21310,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-22",24,24,1875,,0.006,0.001,1172.5,0.059,0.053,0.005,19730.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-27",2,2,0,,0,0.001,3.1,0.063,0.003,0.1055,50.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-28",24,24,967,,0.004,0.001,716.9,0.0591,0.053,0.0243,12061.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-29",24,24,1442,,0.005,0.001,942.9,0.059,0.04,0.0048,15871.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-03",19,19,518,,0.002,0.001,432.6,0.0595,0.073,0.0545,7277.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-04",24,24,1171,,0.004,0.001,811.6,0.0591,0.028,0.0044,13656.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-05",2,2,104,,0,0.001,67.1,0.059,0.003,0.0045,1128.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-06",3,3,0,,0,0.001,14.8,0.06,0.014,0.1093,247.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-08",10,10,17,,0,0.001,93.8,0.0599,0.1,0.1433,1581.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-09",24,24,1418,,0.005,0.001,944.7,0.0593,0.053,0.0055,15898,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-10",8,8,43,,0,0.001,87.6,0.0595,0.051,0.1045,1472.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-11",24,24,714,,0.003,0.001,573.6,0.0593,0.021,0.0046,9648,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-05",1,1,0,,0,0.001,2.6,0.059,0.001,0.044,44.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-09",8,8,0,,0,0.001,63.7,0.0596,0.066,0.1209,1070.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-10",24,24,1357,,0.005,0.001,941,0.0591,0.065,0.0131,15835.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-11",24,24,1574,,0.005,0.001,1019.8,0.0593,0.056,0.0061,17157.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-12",24,24,1935,,0.006,0.001,1212.2,0.0592,0.075,0.0063,20397.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-13",24,24,1784,,0.006,0.001,1129.2,0.059,0.053,0.0052,19004.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-14",23,23,1398,,0.005,0.001,924.1,0.0591,0.037,0.0047,15551.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-16",3,3,0,,0,0.001,15.2,0.0583,0.009,0.05,255,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-17",24,24,745,,0.003,0.001,617.5,0.0593,0.045,0.0179,10389.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-18",22,22,729,,0.003,0.001,559.6,0.0591,0.021,0.0046,9417.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-26",1,1,0,,0,0.001,0.2,0.069,0,0.091,2.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-27",24,24,740,,0.003,0.001,616.7,0.0592,0.093,0.045,10381.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-28",24,24,1029,,0.004,0.001,737.6,0.059,0.029,0.0048,12414,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-29",24,24,1217,,0.004,0.001,845,0.0591,0.03,0.0045,14216.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-30",24,24,2112,,0.007,0.001,1305.1,0.0591,0.059,0.0048,21957.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-07-31",24,24,2159,,0.007,0.001,1318,0.0591,0.044,0.0044,22173.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-01",24,24,1290,,0.004,0.001,890.6,0.059,0.03,0.0045,14989.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-02",24,24,1804,,0.006,0.001,1132.3,0.0591,0.039,0.0037,19051.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-03",24,24,1025,,0.004,0.001,738.2,0.0591,0.025,0.0049,12421.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-04",22,22,1101,,0.004,0.001,744.8,0.0591,0.026,0.0042,12533.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-11",21,21,250,,0.002,0.001,313.8,0.0592,0.115,0.0723,5281.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-12",23,23,1507,,0.005,0.001,983.3,0.059,0.035,0.0044,16546.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-13",6,6,32,,0,0.001,77.6,0.0593,0.024,0.0433,1307.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-14",24,24,2953,,0.009,0.001,1765.9,0.0592,0.136,0.0073,29714.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-15",24,24,2711,,0.008,0.001,1645.7,0.059,0.093,0.0057,27694.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-16",24,24,2371,,0.007,0.001,1467.8,0.059,0.082,0.0055,24702.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-17",18,18,1632,,0.005,0.001,1018.8,0.059,0.038,0.0043,17145.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-20",23,23,1146,,0.004,0.001,818.7,0.0592,0.09,0.0348,13777.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-21",24,24,2057,,0.007,0.001,1292.3,0.0592,0.048,0.0048,21744.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-22",24,24,1061,,0.004,0.001,776.1,0.0592,0.026,0.005,13059.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-23",19,19,1262,,0.004,0.001,855.2,0.0589,0.029,0.0066,14389.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-25",11,11,32,,0.001,0.001,117.7,0.0592,0.069,0.09,1981.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-26",17,17,1157,,0.004,0.001,758.5,0.0591,0.033,0.0046,12763.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-04",24,24,1199,,0.004,0.001,860.9,0.0592,0.071,0.0287,14488.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-05",24,24,2024,,0.006,0.001,1281.7,0.059,0.068,0.0054,21568,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-06",24,24,2374,,0.007,0.001,1470.1,0.0592,0.065,0.0051,24733.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-07",24,24,1123,,0.004,0.001,805.5,0.0592,0.024,0.0039,13553.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-08",24,24,1127,,0.004,0.001,811.3,0.0591,0.422,0.0468,13654,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-09",24,24,1103,,0.004,0.001,806,0.0592,0.032,0.0048,13559.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-10",24,24,553,,0.003,0.001,504.4,0.0592,0.021,0.005,8489.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-15",2,2,0,,0,0.001,1.2,0.061,0.001,0.038,19.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-16",24,24,912,,0.004,0.001,698.8,0.0592,0.106,0.0454,11763.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-17",22,22,1171,,0.004,0.001,799.5,0.0591,0.031,0.0045,13451.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-23",6,6,0,,0,0.001,33.7,0.0593,0.037,0.1317,565.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-27",2,2,0,,0,0.001,1.7,0.059,0.002,0.1265,28.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-28",24,24,910,,0.004,0.001,712,0.0592,0.078,0.0313,11980.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-29",24,24,1328,,0.005,0.001,909,0.0591,0.035,0.0046,15296.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-09-30",24,24,1852,,0.006,0.001,1184,0.0591,0.053,0.0047,19923.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-01",24,24,1890,,0.006,0.001,1202.1,0.0591,0.054,0.0048,20226.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-02",24,24,1511,,0.005,0.001,997.8,0.059,0.039,0.0043,16794.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-03",24,24,1306,,0.005,0.001,895.5,0.0593,0.033,0.0045,15065.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-04",5,5,126,,0.001,0.001,101.9,0.0596,0.004,0.005,1712.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-05",8,8,53,,0.001,0.001,102.5,0.0591,0.013,0.0223,1726.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-06",24,24,1919,,0.006,0.001,1245.7,0.0592,0.037,0.0037,20960.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-11",3,3,0,,0,0.001,5.6,0.0607,0.004,0.0947,93.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-12",24,24,1311,,0.005,0.001,919.5,0.0593,0.081,0.0259,15471.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-13",24,24,1338,,0.005,0.001,915.3,0.059,0.033,0.0045,15402,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-14",24,24,1545,,0.005,0.001,1030.6,0.059,0.038,0.0043,17343.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-15",24,24,1978,,0.006,0.001,1260.9,0.0592,0.058,0.005,21211,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-16",24,24,1399,,0.005,0.001,954.2,0.0592,0.04,0.0047,16055.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-17",24,24,981,,0.004,0.001,726.3,0.0591,0.024,0.0043,12220.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-18",8,8,513,,0.002,0.001,338.1,0.059,0.016,0.0054,5689.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-25",1,1,0,,0,0.001,2.7,0.059,0.002,0.104,45.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-26",24,24,423,,0.002,0.001,444.9,0.0592,0.09,0.0435,7488.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-27",24,24,806,,0.003,0.001,616.9,0.0591,0.025,0.0051,10386.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-10",4,4,0,,0,0.001,21,0.0593,0.008,0.0558,353.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-27",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-28",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-29",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-30",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-01-31",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-27",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-28",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-02-29",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-27",1,0.53,122.43,,0,0.001,58.141,0.059,0.007,0.014,978.751,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-28",5,2.66,312.43,,0.001,0.001,184.815,0.0592,0.035,0.0252,3109.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-06",8,7.03,1955.15,,0.004,0.001,839.207,0.0591,0.051,0.0176,14119.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-07",8,6.84,2071.88,,0.004,0.001,854.842,0.059,0.052,0.0174,14382.786,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-27",3,2.11,215.53,,0.001,0.001,149.529,0.059,0.014,0.0117,2515.491,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-04-30",8,7.35,1459.65,,0.003,0.001,644.155,0.059,0.04,0.0084,10840.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-04",8,7.16,2116.47,,0.004,0.001,871.696,0.059,0.053,0.0099,14668.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-05",9,7.98,2474.28,,0.005,0.001,1008.568,0.059,0.058,0.0127,16973.342,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-06",15,13.3,3740.1,,0.008,0.001,1527.49,0.059,0.083,0.0183,25705.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-07",13,11.32,3563.78,,0.007,0.001,1432.046,0.059,0.077,0.015,24096.218,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-08",11,10.56,3324.5,,0.007,0.001,1339.718,0.059,0.075,0.0075,22541.914,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-25",8,5.9,1592.4,,0.003,0.001,668.923,0.059,0.043,0.0148,11256.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-26",11,10.14,2995.8,,0.006,0.001,1212.31,0.059,0.06,0.0073,20398.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-27",8,7.01,2168.17,,0.004,0.001,878.165,0.059,0.046,0.0116,14777.669,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-28",9,8.07,2502.07,,0.005,0.001,1011.078,0.059,0.059,0.0113,17013.807,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-01",9,7.39,2189.34,,0.005,0.001,891.968,0.059,0.053,0.019,15009.423,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-02",10,9.1,2731.9,,0.006,0.001,1103.24,0.059,0.062,0.0112,18565.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-03",11,9.95,3152,,0.006,0.001,1258.505,0.059,0.069,0.01,21178.09,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-04",11,9.11,2683.32,,0.005,0.0009,1083.108,0.0591,0.06,0.0111,18226.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-08",18,17.3,2884.4,,0.007,0.001,1341.72,0.059,0.072,0.0068,22572.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-09",8,7.6,2262.24,,0.005,0.001,911.488,0.059,0.052,0.008,15334.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-10",9,8.12,2526.41,,0.005,0.001,1012.012,0.059,0.055,0.0097,17027.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-11",8,7.37,2220.94,,0.005,0.001,892.335,0.059,0.049,0.0079,15016.07,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-14",1,0.55,34.1,,0,0.001,31.9,0.059,0.009,0.034,536.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-15",16,14.11,3341.9,,0.007,0.001,1406.973,0.059,0.072,0.0121,23675.661,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-16",8,6.91,2115.42,,0.004,0.001,849.034,0.059,0.052,0.0111,14287.923,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-18",9,7.18,2161.7,,0.004,0.001,872.844,0.059,0.053,0.0111,14687.522,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-19",8,7.35,2205.66,,0.004,0.001,889.321,0.059,0.054,0.0088,14963.793,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-20",8,6.94,2093.45,,0.004,0.001,846.115,0.059,0.051,0.011,14237.394,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-21",9,7.87,2260.16,,0.005,0.001,917.413,0.059,0.054,0.0097,15437.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-22",9,8.38,2603.19,,0.005,0.001,1041.037,0.059,0.057,0.0072,17517.519,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-23",10,9.08,2870.81,,0.006,0.001,1141.7,0.059,0.056,0.0076,19210.116,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-24",9,8.22,2557.7,,0.005,0.001,1018.452,0.059,0.055,0.0082,17136.622,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-25",9,8.34,2605.64,,0.005,0.001,1039.5,0.059,0.059,0.0079,17492.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-26",10,9.53,2982.67,,0.006,0.001,1190.217,0.059,0.07,0.0084,20026.402,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-27",8,6.89,2111.96,,0.004,0.001,851.994,0.059,0.051,0.0125,14337.541,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-28",8,6.91,1992.49,,0.004,0.001,813.026,0.059,0.048,0.0134,13679.221,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-01",8,7.24,1925.44,,0.004,0.001,789.861,0.059,0.047,0.0088,13292.316,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-02",8,6.92,2111.36,,0.004,0.001,846.3,0.059,0.05,0.0124,14241.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-03",8,7.15,2183.67,,0.004,0.001,880.846,0.059,0.051,0.0088,14820.235,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-04",8,7.2,2196.44,,0.004,0.001,883.815,0.059,0.053,0.0085,14870.425,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-05",8,6.96,2146.4,,0.004,0.001,864.068,0.059,0.052,0.0119,14538.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-06",12,11.2,3505.22,,0.007,0.001,1400.934,0.059,0.076,0.0072,23574.166,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-07",11,9.87,2810.38,,0.006,0.001,1131.667,0.059,0.062,0.0085,19041.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-08",8,7.15,2172.7,,0.004,0.001,875.515,0.059,0.046,0.0084,14733.405,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-09",9,8.07,2486.47,,0.005,0.001,999.021,0.059,0.051,0.0074,16809.331,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-10",18,17.28,5243.2,,0.011,0.001,2091.228,0.059,0.102,0.0065,35187.586,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-11",12,11.13,3573.58,,0.007,0.001,1418.934,0.059,0.067,0.0067,23876.456,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-12",10,9.4,2931.38,,0.006,0.001,1169.228,0.059,0.063,0.0072,19674.034,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-13",12,11.09,3522.13,,0.007,0.001,1400.844,0.059,0.074,0.009,23572.334,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-14",8,7.4,2245,,0.005,0.001,904.2,0.059,0.054,0.0083,15215.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-15",10,9.1,2840.6,,0.006,0.001,1135.87,0.059,0.062,0.0099,19112.53,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-16",9,7.15,2165,,0.004,0.001,876.03,0.059,0.048,0.0098,14741.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-17",10,9,2547,,0.005,0.001,1035.606,0.0591,0.057,0.0063,17428.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-18",8,7.34,2234.86,,0.005,0.001,902.432,0.059,0.046,0.0074,15185.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-19",8,7.1,2152.64,,0.004,0.001,873.856,0.059,0.047,0.0115,14705.658,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-20",10,8.39,2575.46,,0.005,0.001,1031.31,0.0591,0.058,0.0069,17352.738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-21",10,8.62,2679.22,,0.005,0.001,1070.501,0.059,0.059,0.0146,18012.849,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-22",12,11.12,2798.4,,0.006,0.001,1156.82,0.059,0.058,0.0089,19463.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-23",9,7.32,2188.66,,0.004,0.001,885.15,0.059,0.048,0.0202,14893.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-24",16,14.38,4192.95,,0.009,0.0009,1688.186,0.059,0.075,0.0056,28406.871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-25",9,7.13,2162.6,,0.004,0.0009,873.335,0.059,0.037,0.0079,14692.931,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-26",8,7.83,2394.4,,0.005,0.001,960.861,0.059,0.04,0.0056,16168.056,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-27",12,10.95,3312.13,,0.007,0.001,1329.299,0.059,0.053,0.0066,22368.423,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-28",11,10.1,3223.6,,0.006,0.001,1281.326,0.059,0.051,0.0059,21561.786,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-29",11,10.1,3225.9,,0.006,0.001,1282.692,0.059,0.051,0.0061,21583.999,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-30",14,13.7,4443,,0.009,0.001,1754.07,0.059,0.065,0.0051,29512.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-07-31",16,14.24,4287.68,,0.009,0.001,1713.84,0.059,0.068,0.0078,28840.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-01",10,8.9,2810.6,,0.006,0.001,1125.61,0.059,0.046,0.0081,18943.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-02",8,6.95,2139.65,,0.004,0.001,865.775,0.059,0.036,0.0076,14568.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-03",9,7.86,2453.86,,0.005,0.001,987.154,0.059,0.042,0.0103,16612.206,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-04",8,7.13,2174.29,,0.004,0.001,878.053,0.059,0.038,0.007,14775.131,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-05",7,6.97,2001.9,,0.004,0.001,816.048,0.059,0.037,0.0061,13730.398,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-06",9,7.15,1886.54,,0.004,0.0009,785.013,0.0589,0.034,0.0077,13209.668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-07",9,7.37,2172.27,,0.004,0.001,887.92,0.059,0.039,0.0177,14938.803,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-08",9,7.3,2128.84,,0.004,0.001,870.188,0.059,0.039,0.0224,14641.372,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-09",9,7.52,2265.04,,0.005,0.001,919.61,0.059,0.04,0.013,15473.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-10",9,7.39,2239.78,,0.005,0.0009,908.202,0.059,0.04,0.0058,15280.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-11",9,7.64,2276.52,,0.005,0.001,924.989,0.059,0.049,0.0148,15565.687,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-12",10,8.67,2669.54,,0.005,0.001,1071.754,0.0591,0.057,0.0065,18033.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-13",14,12.61,4056.64,,0.008,0.001,1615.919,0.0591,0.087,0.0062,27190.546,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-14",19,18.67,5632.54,,0.011,0.001,2252.48,0.059,0.114,0.0063,37904.058,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-15",14,12.64,3975.76,,0.008,0.001,1589.108,0.059,0.085,0.0063,26738.746,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-16",17,16.06,4267.56,,0.009,0.001,1745.948,0.059,0.089,0.0065,29380.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-17",19,17.18,5008.88,,0.01,0.001,2020.333,0.0591,0.104,0.0064,33994.871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-18",21,20.02,4975,,0.01,0.001,2044.384,0.059,0.101,0.0057,34400.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-19",22,20.63,5212.08,,0.011,0.001,2148.804,0.059,0.108,0.0058,36154.504,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-20",23,22.15,5819.7,,0.012,0.001,2361.87,0.059,0.113,0.0064,39743.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-21",14,12.17,3828.45,,0.008,0.001,1528.602,0.059,0.083,0.0074,25723.027,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-22",13,11.41,3529.94,,0.007,0.001,1417.06,0.0591,0.077,0.0065,23846.026,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-23",12,10.18,3157.89,,0.006,0.001,1269.183,0.0591,0.068,0.0082,21355.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-24",13,12.1,3826.46,,0.008,0.001,1531.2,0.059,0.081,0.0087,25761.914,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-25",12,11.7,3731.6,,0.008,0.001,1490.78,0.059,0.064,0.0058,25085.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-26",3,0.6,11.45,,0,0.001,19.172,0.0593,0.023,0.109,322.593,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-28",1,0.22,0.88,,0,0.001,5.06,0.06,0.006,0.148,84.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-30",2,1.98,275.38,,0.001,0.001,157.242,0.059,0.014,0.012,2646.446,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-08-31",11,8.42,2280.2,,0.005,0.001,940.579,0.059,0.053,0.0191,15826.309,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-01",9,7.13,2163.9,,0.004,0.001,884.328,0.059,0.05,0.0091,14881.041,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-02",9,8.1,2491.8,,0.005,0.001,1018.3,0.059,0.059,0.0103,17137.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-03",13,11.13,3463.04,,0.007,0.001,1399.342,0.0591,0.078,0.0085,23548.173,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-04",15,13.17,3865.1,,0.008,0.001,1578.664,0.059,0.069,0.0076,26562.757,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-05",17,16.45,4690.45,,0.01,0.001,1914.317,0.059,0.088,0.0061,32212.412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-06",18,17.82,5101.54,,0.01,0.001,2075.532,0.059,0.093,0.0057,34925.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-07",15,12.9,3266.32,,0.007,0.001,1354.737,0.059,0.061,0.0129,22797.987,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-08",14,12.88,1999.18,,0.005,0.001,925.595,0.059,0.042,0.0108,15576.353,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-09",9,7.12,2096.1,,0.004,0.001,865.296,0.0591,0.037,0.0083,14558.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-10",11,9.14,2836.12,,0.006,0.001,1156.718,0.059,0.064,0.0087,19463.452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-11",19,18.03,5200,,0.011,0.001,2124.008,0.0591,0.109,0.0059,35741.394,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-12",18,17.08,4120.92,,0.009,0.001,1735.688,0.0591,0.086,0.0087,29209.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-13",17,15.02,3484.84,,0.007,0.001,1484.58,0.059,0.077,0.0095,24984.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-14",14,13.12,4073,,0.008,0.001,1649.812,0.0591,0.087,0.0076,27762.392,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-15",16,13.47,3811.31,,0.008,0.0009,1564.781,0.0616,0.083,0.0093,26331.142,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-16",14,12.4,3812.05,,0.008,0.001,1550.784,0.0591,0.083,0.0066,26095.658,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-17",12,10.65,3359.2,,0.007,0.0009,1364.32,0.0591,0.076,0.0066,22957.055,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-18",12,10.64,3310.12,,0.007,0.001,1345.098,0.0591,0.074,0.0064,22635.292,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-19",10,9.35,2903.85,,0.006,0.001,1182.09,0.059,0.066,0.0077,19889.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-20",10,9.08,2836.4,,0.006,0.001,1149.294,0.059,0.056,0.0103,19340.568,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-21",17,16.1,4907.8,,0.01,0.001,1982.91,0.059,0.105,0.0083,33367.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-22",10,8.8,2688.39,,0.006,0.001,1096.46,0.0591,0.062,0.0065,18448.912,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-23",12,10.34,3207.76,,0.007,0.001,1300.56,0.059,0.071,0.0068,21883.628,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-24",13,11.2,3449.66,,0.007,0.001,1399.68,0.059,0.076,0.0075,23551.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-25",14,12.3,3764.92,,0.008,0.001,1527.594,0.059,0.082,0.0071,25706.656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-26",9,7.25,2132.38,,0.004,0.001,877.776,0.0591,0.05,0.0087,14768.077,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-27",9,7.63,2167.24,,0.005,0.001,906.103,0.059,0.038,0.0092,15247.856,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-28",12,10.76,3307.15,,0.007,0.001,1347.103,0.059,0.053,0.007,22667.741,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-29",14,13.05,3908,,0.008,0.001,1595.3,0.059,0.068,0.0049,26843.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-09-30",14,12.21,3690.19,,0.008,0.001,1508.351,0.059,0.066,0.0079,25381.197,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-01",12,11.18,3497.02,,0.007,0.001,1418.92,0.059,0.056,0.0063,23875.586,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-02",13,12.06,3656.98,,0.007,0.001,1483.246,0.059,0.057,0.0075,24959.256,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-03",13,13,4024,,0.008,0.001,1626.5,0.059,0.061,0.0048,27369.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-04",21,20.55,5484.32,,0.011,0.001,2272.752,0.059,0.082,0.0045,38245.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-05",20,19.08,5974.08,,0.012,0.001,2402.84,0.059,0.124,0.0081,40433.028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-06",20,18.12,5390.6,,0.011,0.001,2182.668,0.059,0.108,0.0073,36726.416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-07",18,16.49,4815.54,,0.01,0.0009,1958.278,0.0591,0.1,0.0061,32954.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-08",17,16.08,4764.58,,0.01,0.001,1930.442,0.059,0.099,0.0075,32486.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-09",18,17.82,5638.77,,0.011,0.001,2257.437,0.059,0.118,0.0065,37986.985,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-10",9,8.09,2271.27,,0.005,0.001,937.106,0.059,0.056,0.0094,15766.686,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-11",8,7.36,2232,,0.005,0.001,910.784,0.059,0.054,0.0081,15325.704,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-12",20,19.97,5435.43,,0.011,0.001,2223.2,0.059,0.111,0.0061,37405.075,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-13",19,17.89,4119.97,,0.009,0.001,1738.279,0.059,0.088,0.0065,29252.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-14",12,10.44,3231.48,,0.007,0.001,1308.437,0.059,0.072,0.0069,22013.842,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-15",12,10.57,3272,,0.007,0.001,1325.479,0.0591,0.073,0.0068,22303.345,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-16",19,17.27,4865.12,,0.01,0.001,1982.323,0.0591,0.103,0.0064,33356.126,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-17",12,10.31,3175.77,,0.006,0.001,1283.004,0.0591,0.05,0.0059,21589.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-18",9,7.5,2251.84,,0.005,0.001,921.911,0.0591,0.039,0.0056,15512.527,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-19",13,11.25,3429.2,,0.007,0.001,1390.155,0.059,0.074,0.0068,23394.425,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-20",20,19.13,5396.42,,0.011,0.001,2211.212,0.059,0.112,0.0066,37211.434,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-21",11,9.65,2613.96,,0.006,0.001,1102.258,0.0591,0.053,0.0055,18546.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-22",9,7.43,2180.76,,0.005,0.001,905.071,0.059,0.049,0.0151,15230.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-23",17,14.4,4146.78,,0.009,0.001,1698.444,0.059,0.084,0.0069,28580.431,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-25",1,0.03,0,,0,0.001,0.099,0.059,0,0,1.683,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-26",19,17.7,5071.37,,0.011,0.001,2087.194,0.0591,0.116,0.0068,35121.612,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-27",17,15.11,4035.4,,0.008,0.001,1669.159,0.059,0.091,0.0108,28090.132,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-28",9,7.35,2110.8,,0.004,0.0009,872.045,0.059,0.051,0.0076,14674.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-29",21,19.2,5420.95,,0.011,0.001,2216.455,0.059,0.106,0.0064,37295.405,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-30",9,7.67,2335.17,,0.005,0.001,951.845,0.059,0.054,0.0128,16015.294,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-10-31",9,7.63,2259.02,,0.005,0.001,936.399,0.059,0.053,0.0122,15757.121,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-01",11,9.41,2878.59,,0.006,0.001,1188.215,0.059,0.066,0.0162,19994.416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-02",20,17.68,5193.35,,0.011,0.001,2138.703,0.059,0.113,0.0076,35990.602,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-03",12,9.64,2720.36,,0.006,0.001,1134.177,0.059,0.062,0.0133,19083.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-04",10,8.45,2589.56,,0.005,0.001,1064.575,0.0591,0.059,0.007,17912.768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-05",11,9.7,3052.09,,0.006,0.001,1248.347,0.0591,0.068,0.0066,21004.947,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-07",9,7.65,1106.05,,0.003,0.001,547.115,0.059,0.028,0.0117,9205.135,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-09",10,9.28,2772.2,,0.006,0.001,1151.068,0.059,0.047,0.0121,19368.376,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-10",17,15.09,3867.48,,0.008,0.001,1638.157,0.059,0.075,0.0058,27564.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-11",8,6.95,2138.85,,0.004,0.001,885.315,0.059,0.05,0.0109,14895.192,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-12",9,7.17,2181.1,,0.005,0.001,902.605,0.059,0.052,0.0104,15187.846,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-14",10,8.15,2397.8,,0.005,0.001,1004.569,0.0591,0.044,0.0095,16903.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-15",9,7.22,2110.12,,0.004,0.001,877.626,0.0591,0.038,0.0104,14769.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-16",11,9.21,2719.15,,0.006,0.001,1125.62,0.059,0.046,0.008,18940.452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-17",9,7.18,2230.8,,0.005,0.001,917.114,0.0591,0.04,0.0092,15430.674,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-20",9,8.47,2448.41,,0.005,0.001,1023.674,0.059,0.058,0.0078,17227.439,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-21",9,7.72,2330.28,,0.005,0.001,962.032,0.059,0.057,0.0086,16188.886,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-23",14,12.16,2948.04,,0.006,0.001,1263.032,0.059,0.073,0.01,21254.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-24",17,16.27,4238.07,,0.009,0.001,1799.654,0.059,0.096,0.007,30284.996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-27",11,10.6,2976,,0.006,0.001,1242.14,0.059,0.041,0.0056,20902.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-28",18,16.1,3070.72,,0.007,0.001,1389.426,0.059,0.045,0.0056,23380.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-29",11,9.18,2364.5,,0.005,0.001,999.124,0.059,0.035,0.0069,16811.816,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-11-30",21,19.09,5078.67,,0.011,0.001,2118.498,0.059,0.107,0.0093,35647.609,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-01",9,7.7,2297.75,,0.005,0.001,957.99,0.059,0.057,0.0124,16120.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-02",9,7.45,2267.25,,0.005,0.001,941.905,0.059,0.049,0.0083,15849.415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-03",17,14.97,4033.45,,0.009,0.001,1700.366,0.059,0.087,0.0108,28614.483,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-04",9,7.68,2323.4,,0.005,0.001,967.52,0.059,0.056,0.0083,16280.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-05",10,8.16,2406.64,,0.005,0.001,1004.772,0.059,0.058,0.0119,16906.916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-06",9,7.45,2269.2,,0.005,0.001,943.719,0.0591,0.043,0.0068,15878.116,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-07",11,9.16,2730.08,,0.006,0.001,1135.656,0.0591,0.063,0.0125,19111.088,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-08",10,8.48,2611,,0.005,0.001,1083.632,0.059,0.061,0.0077,18232.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-09",16,14.06,3765.5,,0.008,0.001,1594.765,0.059,0.087,0.0096,26836.217,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-10",17,14.36,3412.52,,0.007,0.001,1482.742,0.0591,0.077,0.0176,24955.121,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-13",10,9.83,1730.87,,0.004,0.001,831.911,0.059,0.042,0.0066,13999.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-14",1,0.07,1.89,,0,0.001,2.821,0.059,0.001,0.056,47.502,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-20",10,8.65,2202.2,,0.005,0.001,989.762,0.059,0.052,0.0125,16654.379,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-21",17,14.19,3760.13,,0.008,0.001,1597.822,0.059,0.089,0.0104,26887.73,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-23",18,16.18,2900.08,,0.007,0.001,1332.844,0.059,0.068,0.0102,22428.476,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-24",17,15.25,2689.58,,0.006,0.001,1258.547,0.059,0.066,0.0135,21181.052,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-25",6,5.53,803.37,,0.002,0.001,398.205,0.059,0.019,0.0062,6701.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-27",8,7.23,1036.06,,0.003,0.001,517.02,0.059,0.03,0.0191,8699.483,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-28",16,14.05,3320.45,,0.007,0.001,1449.045,0.059,0.075,0.008,24383.035,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-29",9,7.43,1259.17,,0.003,0.001,592.113,0.059,0.038,0.0184,9963.087,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-30",9,7.43,1072.5,,0.003,0.001,529.333,0.059,0.034,0.0183,8905.082,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT1",,"2020-12-31",9,7.33,1445.02,,0.003,0.001,652.084,0.059,0.041,0.0236,10972.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-27",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-28",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-29",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-30",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-01-31",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-27",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-28",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-02-29",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-01",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-02",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-03",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-04",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-05",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-06",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-07",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-08",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-09",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-10",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-11",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-12",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-13",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-14",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-15",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-16",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-17",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-18",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-19",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-20",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-21",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-22",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-23",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-24",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-25",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-26",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-27",0,,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-28",1,0.13,44.07,,0,0.001,17.979,0.059,0.001,0.006,302.562,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-04",3,2.32,279.8,,0.001,0.001,166.276,0.059,0.017,0.029,2797.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-05",7,6.07,886.4,,0.002,0.001,433.178,0.059,0.022,0.0176,7289.513,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-06",9,7.35,1990.69,,0.004,0.001,858.682,0.059,0.054,0.0232,14448.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-07",9,7.15,2112.53,,0.004,0.0009,874.947,0.0589,0.053,0.0102,14722.757,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-08",6,5.8,1493,,0.003,0.001,645.66,0.059,0.041,0.0092,10862.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-09",2,1.05,155.5,,0,0.001,76.05,0.0595,0.005,0.0675,1280.475,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-27",3,2.43,246.76,,0.001,0.001,170.79,0.059,0.024,0.021,2874.397,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-28",4,2.7,234.7,,0.001,0.001,191.722,0.059,0.021,0.0265,3226.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-04-30",10,9.2,1828.92,,0.004,0.001,821.852,0.059,0.044,0.0079,13829.91,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-02",2,1.82,206.68,,0.001,0.001,124.642,0.059,0.013,0.0135,2097.748,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-03",14,12.89,2535.89,,0.006,0.001,1140.817,0.059,0.055,0.0094,19199.201,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-04",9,7.51,2150.57,,0.005,0.001,892.598,0.059,0.044,0.0147,15017.568,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-05",10,8.2,2510.2,,0.005,0.001,1021.016,0.0591,0.042,0.0075,17180.256,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-06",15,13.56,3771.76,,0.008,0.001,1541.803,0.059,0.064,0.0083,25944.169,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-07",13,11.6,3604.25,,0.007,0.001,1450.165,0.059,0.057,0.0078,24399.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-08",12,10.81,3351.11,,0.007,0.001,1349.801,0.059,0.056,0.0146,22712.159,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-09",8,7.01,2066.43,,0.004,0.001,848.262,0.059,0.039,0.0204,14273.812,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-25",11,10.32,2753.44,,0.006,0.001,1168.32,0.059,0.052,0.0105,19659.212,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-26",17,15.48,3797.46,,0.008,0.001,1588.746,0.059,0.071,0.0129,26735.056,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-27",9,7.35,2212.89,,0.005,0.001,900.854,0.059,0.041,0.0203,15159.042,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-28",10,8.36,2542.29,,0.005,0.001,1030.505,0.059,0.045,0.0177,17339.276,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-01",9,7.68,2222.77,,0.005,0.001,912.378,0.059,0.041,0.0107,15352.03,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-02",11,9.35,2765,,0.006,0.001,1119.85,0.059,0.048,0.0155,18842.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-03",12,10.2,3195.84,,0.006,0.001,1274.552,0.059,0.053,0.0075,21447.292,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-04",11,9.36,2712.96,,0.006,0.001,1098.32,0.059,0.047,0.0143,18481.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-08",2,0.61,46.05,,0,0.001,35.325,0.059,0.01,0.0385,594.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-09",18,17.61,3700.76,,0.008,0.001,1602.912,0.059,0.079,0.0063,26968.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-10",10,8.29,2554.38,,0.005,0.001,1021.987,0.0591,0.049,0.0133,17195.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-11",9,7.61,2247.39,,0.005,0.001,905.109,0.059,0.044,0.0183,15230.587,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-15",10,8.6,2430.68,,0.005,0.001,987.652,0.059,0.051,0.0096,16619.872,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-16",9,7.2,2154,,0.004,0.001,865.615,0.0591,0.046,0.0081,14567.815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-18",9,7.45,2191.24,,0.004,0.001,888.535,0.059,0.048,0.0149,14950.873,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-19",9,7.63,2243.89,,0.005,0.001,906.219,0.059,0.048,0.0178,15249.367,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-20",9,7.2,2130.56,,0.004,0.0009,861.504,0.0591,0.046,0.0077,14497.256,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-21",10,8.15,2294.56,,0.005,0.0009,931.055,0.0591,0.051,0.0083,15667.559,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-22",10,8.6,2640.1,,0.005,0.0009,1053.44,0.0591,0.049,0.0055,17726.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-23",10,9.35,2910.69,,0.006,0.001,1156.272,0.059,0.055,0.0069,19456.868,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-24",9,8.6,2606.86,,0.005,0.001,1041.026,0.059,0.052,0.0068,17515.414,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-25",9,8.62,2648.04,,0.005,0.001,1054.524,0.059,0.053,0.0068,17746.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-26",10,9.83,3028.01,,0.006,0.001,1208.168,0.059,0.06,0.0067,20329.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-27",9,7.15,2141.64,,0.004,0.001,864.853,0.0591,0.046,0.0098,14553.797,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-28",9,7.1,2019.87,,0.004,0.001,823.785,0.059,0.043,0.0079,13861.358,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-01",9,7.98,2012.64,,0.004,0.001,839.534,0.059,0.044,0.0103,14126.254,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-02",9,7.11,2140.64,,0.004,0.001,858.23,0.059,0.044,0.0093,14441.679,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-03",9,7.4,2219.35,,0.005,0.001,894.245,0.0591,0.047,0.0064,15048.225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-04",9,7.39,2227.68,,0.005,0.001,894.756,0.059,0.046,0.0063,15054.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-05",9,7.15,2175.2,,0.004,0.001,874.8,0.059,0.044,0.0064,14720.629,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-06",13,11.32,3531.5,,0.007,0.001,1403.89,0.0591,0.067,0.0064,23623.678,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-07",11,10.1,2838.75,,0.006,0.001,1143.085,0.059,0.057,0.0071,19236.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-08",9,7.45,2215.28,,0.005,0.001,894.064,0.059,0.044,0.0066,15045.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-09",9,8.34,2523.57,,0.005,0.001,1013.431,0.059,0.05,0.0071,17054.046,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-10",18,17.57,5295.89,,0.011,0.001,2107.489,0.059,0.094,0.0058,35462.349,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-11",12,11.35,3615.92,,0.007,0.001,1430.758,0.059,0.068,0.0064,24073.692,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-12",10,9.58,2966.36,,0.006,0.001,1179.846,0.059,0.057,0.0063,19855.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-13",12,10.85,3491.85,,0.007,0.001,1376.18,0.059,0.063,0.0095,23158.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-14",8,7.17,2212.61,,0.004,0.001,884.52,0.059,0.045,0.0076,14884.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-15",10,8.88,2812.16,,0.006,0.001,1114.56,0.059,0.054,0.0101,18754.764,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-16",8,6.97,2141.28,,0.004,0.001,858.949,0.059,0.044,0.011,14454.703,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-17",9,8.73,2513.99,,0.005,0.001,1013.28,0.059,0.049,0.0067,17046.581,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-18",8,7.1,2199.9,,0.004,0.001,880.255,0.059,0.046,0.008,14814.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-19",8,6.85,2121.5,,0.004,0.001,851.818,0.059,0.044,0.0119,14333.828,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-20",9,8.17,2544.1,,0.005,0.001,1010.594,0.059,0.05,0.0073,17004.796,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-21",10,8.4,2654.3,,0.005,0.001,1049.885,0.059,0.053,0.0063,17666.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-22",12,10.9,2769.22,,0.006,0.001,1136.636,0.059,0.054,0.0091,19127.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-23",9,7.11,2166.8,,0.004,0.001,865.934,0.0591,0.044,0.0102,14572.307,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-24",15,14.13,4158.69,,0.008,0.001,1663.75,0.059,0.077,0.0065,27993.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-25",8,6.9,2129.7,,0.004,0.001,851.066,0.059,0.043,0.0129,14323.086,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-26",8,7.56,2356.67,,0.005,0.001,937.179,0.059,0.048,0.0073,15771.788,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-27",13,11.23,3357.6,,0.007,0.001,1347.53,0.0591,0.064,0.0063,22674.566,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-28",11,10.33,3260.8,,0.007,0.001,1294.986,0.059,0.062,0.0066,21791.274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-29",11,10.35,3266.65,,0.007,0.001,1298.42,0.059,0.063,0.0068,21848.07,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-30",14,14,4487,,0.009,0.001,1771.4,0.059,0.081,0.0058,29806.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-07-31",16,14.45,4331.66,,0.009,0.001,1726.765,0.059,0.081,0.0081,29056.003,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-01",10,9.12,2843.44,,0.006,0.001,1136.828,0.059,0.055,0.0084,19129.748,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-02",8,7.17,2169.32,,0.004,0.001,877.393,0.059,0.044,0.0081,14765.179,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-03",10,8.12,2489,,0.005,0.0009,1002.128,0.0588,0.05,0.0082,16861.254,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-04",8,7.35,2215.3,,0.005,0.001,894.545,0.059,0.045,0.0073,15054.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-05",10,9.78,2621.22,,0.005,0.001,1073.746,0.059,0.053,0.0067,18068.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-06",15,12.92,3024.89,,0.006,0.001,1277.114,0.059,0.063,0.0138,21491.573,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-07",9,7.15,2165.4,,0.004,0.001,872.26,0.0591,0.045,0.0111,14677.415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-08",9,7.12,2119.5,,0.004,0.0009,855.738,0.0591,0.044,0.011,14399.718,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-09",8,7.28,2249.28,,0.005,0.001,904.539,0.059,0.046,0.0071,15219.415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-10",8,7.15,2204.25,,0.004,0.001,886.155,0.059,0.046,0.0079,14912.98,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-11",9,7.42,2256,,0.005,0.001,905.43,0.059,0.048,0.0078,15239.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-12",9,8.47,2637.73,,0.005,0.001,1051.79,0.059,0.053,0.0069,17696.727,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-13",13,12.4,4035.78,,0.008,0.001,1597.186,0.059,0.076,0.0064,26876.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-14",19,18.43,5613.29,,0.011,0.001,2228.931,0.059,0.102,0.0062,37509.883,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-15",13,12.38,3945.66,,0.008,0.001,1565.592,0.059,0.074,0.0064,26345.022,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-16",17,15.87,4247.35,,0.009,0.001,1726.447,0.059,0.073,0.0069,29049.026,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-17",18,16.9,4961.8,,0.01,0.001,1988.4,0.059,0.085,0.0061,33458.242,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-18",19,18.2,4429.21,,0.009,0.001,1826.996,0.059,0.083,0.0061,30739.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-19",16,15.93,4526.51,,0.009,0.001,1818.669,0.059,0.081,0.0056,30602.443,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-20",23,22.08,5829.08,,0.012,0.001,2351.852,0.059,0.099,0.0069,39573.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-21",13,11.92,3805.36,,0.008,0.001,1507.574,0.059,0.07,0.0083,25367.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-22",12,11.17,3501.01,,0.007,0.001,1395.218,0.059,0.066,0.0067,23476.538,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-23",11,9.93,3130.01,,0.006,0.001,1248.403,0.059,0.06,0.0095,21009.413,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-24",13,11.83,3801.79,,0.008,0.001,1510.313,0.059,0.071,0.0088,25413.179,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-25",12,11.48,3714.74,,0.007,0.001,1473.476,0.059,0.067,0.006,24792.604,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-26",9,8.05,2000.39,,0.004,0.001,847.938,0.059,0.044,0.0133,14268.822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-27",15,13.32,4254.4,,0.009,0.001,1700.164,0.0591,0.074,0.0057,28607.908,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-28",10,8.9,2618.29,,0.006,0.001,1091.013,0.059,0.05,0.0106,18359.199,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-29",8,7.05,2082.96,,0.004,0.001,853.856,0.059,0.045,0.0149,14368.729,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-08-31",10,8.11,2257.08,,0.005,0.001,916.415,0.059,0.047,0.011,15421.848,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-01",8,6.91,2133.17,,0.004,0.001,861.597,0.059,0.045,0.0116,14498.341,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-02",9,7.85,2458.89,,0.005,0.001,992.334,0.059,0.05,0.0111,16699.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-03",12,10.9,3429.69,,0.007,0.001,1372.567,0.059,0.075,0.0117,23097.416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-04",14,12.92,3831.94,,0.008,0.001,1550.031,0.059,0.06,0.0075,26079.783,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-05",17,16.67,4722.29,,0.01,0.001,1916.994,0.059,0.088,0.0059,32260.157,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-06",18,17.98,5132.84,,0.01,0.001,2074.904,0.059,0.09,0.0054,34913.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-07",16,13.2,3300.46,,0.007,0.0009,1365.776,0.0588,0.062,0.0094,22980.854,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-08",15,13.12,2036.54,,0.005,0.001,939.573,0.0591,0.042,0.0084,15811.815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-09",8,6.9,2067.04,,0.004,0.001,843.232,0.059,0.043,0.0129,14188.248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-10",10,8.91,2806.64,,0.006,0.001,1130.593,0.059,0.055,0.0111,19026.155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-11",18,17.75,5169.5,,0.011,0.001,2090.225,0.059,0.088,0.005,35172.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-12",18,16.82,4082.13,,0.009,0.001,1704.341,0.059,0.074,0.0074,28680.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-13",17,14.73,3457.62,,0.007,0.001,1455.641,0.059,0.068,0.0121,24494.113,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-14",13,12.95,4051.85,,0.008,0.001,1625.73,0.059,0.075,0.0058,27358.345,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-15",15,13.23,3782.11,,0.008,0.001,1538.74,0.059,0.072,0.011,25892.107,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-16",13,12.18,3776.47,,0.008,0.001,1522.579,0.059,0.071,0.0067,25621.645,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-17",11,10.43,3329.8,,0.007,0.001,1339.858,0.059,0.066,0.0067,22543.671,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-18",11,10.41,3272.52,,0.007,0.001,1318.782,0.059,0.063,0.0065,22192.926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-19",10,9.1,2852.04,,0.006,0.001,1151.27,0.059,0.056,0.0073,19370.424,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-20",10,8.85,2800.55,,0.006,0.001,1122.709,0.059,0.056,0.0123,18891.626,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-21",17,15.83,4871.11,,0.01,0.001,1951.598,0.059,0.098,0.0082,32840.052,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-22",9,8.51,2642.93,,0.005,0.001,1067.399,0.059,0.057,0.0074,17959.891,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-23",11,10.1,3169.7,,0.006,0.001,1272.9,0.059,0.066,0.0077,21418.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-24",12,10.97,3415.8,,0.007,0.001,1372.702,0.059,0.07,0.0085,23096.848,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-25",13,12.08,3734.24,,0.008,0.001,1500.672,0.059,0.072,0.007,25253.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-26",8,7.05,2099.64,,0.004,0.001,855.166,0.059,0.045,0.0096,14391.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-27",9,6.65,1988.86,,0.004,0.001,805.254,0.059,0.05,0.0222,13548.606,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-28",12,10.54,3283.88,,0.007,0.001,1320.852,0.059,0.064,0.011,22227.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-29",13,12.83,3881.47,,0.008,0.001,1569.206,0.059,0.072,0.0059,26405.691,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-09-30",14,11.93,3661.29,,0.007,0.001,1480.638,0.059,0.063,0.0092,24915.741,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-01",12,10.95,3468.9,,0.007,0.001,1393.905,0.059,0.056,0.0068,23451.525,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-02",13,11.87,3629.65,,0.007,0.001,1458.031,0.059,0.056,0.0102,24535.999,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-03",13,12.8,3997,,0.008,0.001,1601.1,0.059,0.06,0.0051,26938.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-04",15,14.13,4193.16,,0.009,0.001,1696.804,0.059,0.065,0.0055,28553.015,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-05",20,18.8,5932.14,,0.012,0.001,2367.066,0.059,0.11,0.0086,39832.391,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-06",19,17.85,5354.65,,0.011,0.001,2150.262,0.059,0.098,0.0092,36178.678,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-07",17,16.18,4752.12,,0.01,0.001,1919.286,0.059,0.089,0.0063,32295.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-08",17,15.85,4705.45,,0.01,0.001,1893.056,0.059,0.097,0.0094,31853.191,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-09",18,17.56,5593.61,,0.011,0.001,2222.112,0.059,0.106,0.0063,37394.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-10",9,7.85,2241.34,,0.005,0.001,911.019,0.059,0.054,0.0154,15329.292,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-11",8,7.1,2193.85,,0.004,0.001,884.3,0.059,0.052,0.0088,14879.09,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-12",20,19.78,5409.24,,0.011,0.001,2196.226,0.059,0.11,0.0062,36954.284,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-13",13,11.45,2881.79,,0.006,0.001,1194.778,0.059,0.063,0.0078,20102.157,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-14",11,10.18,3195.92,,0.006,0.001,1280.83,0.059,0.07,0.0075,21551.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-15",11,10.32,3240.87,,0.007,0.001,1300.095,0.059,0.07,0.0073,21881.636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-16",18,17.03,4831.15,,0.01,0.001,1953.554,0.059,0.1,0.0071,32874.07,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-17",11,10.08,3144.04,,0.006,0.001,1257.448,0.059,0.05,0.0065,21159.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-18",8,7.23,2217.67,,0.005,0.001,896.834,0.059,0.039,0.0066,15090.721,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-19",12,10.97,3387.67,,0.007,0.001,1360.648,0.059,0.074,0.0081,22893.753,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-20",20,17.99,5053.76,,0.01,0.001,2057.116,0.059,0.11,0.0075,34615.242,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-21",6,5.15,1269.05,,0.003,0.001,538.7,0.059,0.028,0.0095,9065.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-22",9,7.15,2147.45,,0.004,0.001,877.006,0.059,0.05,0.0096,14758.878,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-23",16,13.95,4079.03,,0.008,0.001,1653.211,0.059,0.084,0.0086,27816.487,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-26",18,17.18,4951.15,,0.01,0.001,2013.655,0.059,0.112,0.0077,33886.77,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-27",17,14.78,3975.82,,0.008,0.001,1623.138,0.0591,0.09,0.0095,27313.632,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-28",8,7.07,2053.78,,0.004,0.001,839.022,0.059,0.048,0.0089,14117.327,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-29",20,18.97,5389.04,,0.011,0.001,2184.159,0.059,0.107,0.0076,36750.773,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-30",9,7.48,2293.45,,0.005,0.001,923.581,0.0591,0.056,0.0119,15539.375,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-10-31",9,7.4,2233.6,,0.005,0.001,910.8,0.059,0.054,0.0172,15326.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-01",11,9.18,2844.58,,0.006,0.001,1158.213,0.0591,0.063,0.0082,19489.238,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-02",19,17.38,5166.67,,0.011,0.001,2099.18,0.059,0.116,0.0071,35323.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-03",12,9.35,2691.35,,0.006,0.001,1105.752,0.059,0.06,0.0124,18609.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-04",9,8.25,2554.5,,0.005,0.001,1039.183,0.059,0.06,0.0081,17486.133,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-05",10,9.5,3021.64,,0.006,0.001,1224.41,0.059,0.069,0.0073,20600.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-07",9,7.41,1081.67,,0.003,0.001,524.367,0.059,0.027,0.0177,8823.091,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-09",10,9.08,2711,,0.006,0.001,1109.38,0.059,0.045,0.0058,18668.304,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-10",17,15.03,3841.29,,0.008,0.001,1615.868,0.059,0.074,0.0059,27190.081,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-11",8,6.93,2122.56,,0.004,0.001,871.528,0.059,0.049,0.0125,14666.157,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-12",9,7.13,2165.12,,0.004,0.001,888.183,0.0591,0.05,0.0109,14946.511,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-14",10,8.12,2368.33,,0.005,0.001,983.612,0.059,0.044,0.0122,16552.414,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-15",9,7.18,2097.8,,0.004,0.001,865.208,0.059,0.039,0.0102,14557.058,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-16",11,9.19,2695.64,,0.006,0.001,1106.034,0.059,0.048,0.0092,18609.709,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-17",9,7.15,2207.96,,0.005,0.001,900.996,0.059,0.04,0.0104,15162.689,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-20",9,8.41,2426.43,,0.005,0.001,1007.183,0.059,0.057,0.0077,16948.232,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-21",9,7.68,2306.68,,0.005,0.001,946.34,0.059,0.056,0.0084,15924.61,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-23",14,11.62,2760.71,,0.006,0.001,1183.459,0.059,0.077,0.0138,19917.571,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-24",9,7.63,2177.79,,0.005,0.001,894.519,0.059,0.056,0.0184,15051.287,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-27",11,10.58,2976.6,,0.006,0.001,1233.024,0.059,0.041,0.0057,20748.196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-28",18,15.4,2797.08,,0.006,0.0009,1278.561,0.0593,0.053,0.0082,21513.249,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-29",10,8.98,2330.92,,0.005,0.001,976.784,0.059,0.037,0.0084,16437.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-11-30",21,19.03,5089.29,,0.011,0.001,2102.008,0.059,0.1,0.011,35372.109,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-01",9,7.66,2267.68,,0.005,0.001,936.331,0.059,0.056,0.0152,15756.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-02",9,7.41,2208.17,,0.005,0.001,909.528,0.0591,0.055,0.0091,15305.407,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-03",17,14.86,3939.61,,0.008,0.001,1645.931,0.059,0.092,0.0119,27695.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-04",9,7.65,2241.18,,0.005,0.001,925.726,0.0591,0.055,0.0079,15576.308,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-05",10,8.14,2327.4,,0.005,0.001,962.728,0.059,0.057,0.015,16200.721,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-06",9,7.42,2195.25,,0.005,0.001,904.46,0.0591,0.041,0.0068,15220.516,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-07",11,9.15,2674.12,,0.006,0.001,1101.948,0.0591,0.063,0.0155,18540.978,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-08",10,8.43,2562.46,,0.005,0.001,1052.639,0.059,0.061,0.0073,17712.641,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-09",16,13.98,3720.79,,0.008,0.001,1562.163,0.059,0.094,0.0126,26285.669,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-10",9,7.45,1994.85,,0.004,0.001,835.075,0.059,0.043,0.015,14053.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-13",6,4.75,715.32,,0.002,0.001,347.361,0.059,0.025,0.0225,5845.023,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-20",3,1.46,161.44,,0,0.001,97.907,0.059,0.022,0.069,1648.053,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-21",16,13.7,3682.64,,0.008,0.001,1545.844,0.059,0.087,0.0128,26014.078,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-23",17,15.38,2799.33,,0.006,0.001,1261.018,0.059,0.065,0.0142,21218.63,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-24",8,7.07,1220.2,,0.003,0.001,559.29,0.059,0.035,0.0141,9411.825,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-27",8,7.02,1013,,0.003,0.001,497.672,0.059,0.029,0.006,8376.126,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-28",9,7.12,2167.56,,0.005,0.001,894.908,0.059,0.056,0.0164,15058.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-29",9,7.2,1233.95,,0.003,0.001,570.975,0.059,0.035,0.02,9607.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-30",9,7.23,1067.9,,0.003,0.001,515.446,0.059,0.031,0.0254,8671.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","AES Huntington Beach",335,"CT2",,"2020-12-31",9,7.12,1421.98,,0.003,0.001,632.468,0.059,0.039,0.0159,10642.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-06",4,3.1,138.74,,0.001,0.001,133.066,0.0593,0.046,0.102,2238.162,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-10",8,7.55,351.95,,0.002,0.001,327.125,0.0591,0.031,0.0186,5504.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-11",3,2.28,101.04,,0,0.001,95.3,0.059,0.018,0.0783,1602.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-14",10,8.83,404.99,,0.002,0.001,379.025,0.059,0.05,0.0408,6377.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-17",4,2.8,114.88,,0.001,0.001,112.182,0.059,0.045,0.0385,1888.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-25",3,1.53,54.56,,0,0.001,56.083,0.0593,0.036,0.2953,943.179,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-29",4,2.85,131.29,,0.001,0.001,123.671,0.0593,0.042,0.175,2079.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-30",5,3.13,131.13,,0.001,0.001,126.615,0.059,0.053,0.1632,2130.627,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-04",3,1.6,58.12,,0,0.001,58.544,0.0597,0.035,0.2773,984.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-05",4,2.64,107.88,,0.001,0.001,104.322,0.0593,0.037,0.1548,1754.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-06",4,2.64,108.3,,0.001,0.001,105.056,0.0595,0.038,0.1563,1767.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-07",4,2.65,108.65,,0.001,0.001,105.301,0.059,0.039,0.1523,1771.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-08",4,2.52,102.68,,0.001,0.001,99.452,0.0593,0.038,0.2033,1673.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-09",5,4.1,189.24,,0.001,0.001,176.756,0.059,0.045,0.0854,2974.446,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-10",5,4.1,189.34,,0.001,0.001,176.786,0.0592,0.044,0.0856,2974.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-11",4,2.6,105.2,,0.001,0.001,102.62,0.0593,0.037,0.1488,1725.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-15",10,8.7,398.28,,0.002,0.001,370.136,0.059,0.05,0.0495,6227.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-19",10,8.68,397.72,,0.002,0.001,368.788,0.059,0.051,0.0505,6206.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-22",10,9.4,440.4,,0.002,0.001,404.8,0.059,0.04,0.0241,6811.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-23",2,1.3,54.3,,0,0.001,51.49,0.059,0.016,0.114,867.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-10",4,1.39,28.98,,0,0.001,36.228,0.0593,0.072,0.2395,609.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-12",4,2.71,111.21,,0.001,0.001,107.908,0.0593,0.036,0.1105,1816.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-30",4,2.83,135.27,,0.001,0.001,126.216,0.0593,0.038,0.0988,2123.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-07-31",4,3.23,143.99,,0.001,0.001,136.422,0.059,0.041,0.066,2297.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-13",4,2.85,117.28,,0.001,0.001,114.07,0.059,0.04,0.106,1919.923,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-14",7,5.95,290.76,,0.001,0.001,268.513,0.059,0.049,0.0581,4515.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-15",6,5,237.36,,0.001,0.001,220.718,0.059,0.042,0.0525,3715.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-16",4,2.68,109.04,,0.001,0.001,106.472,0.059,0.036,0.1133,1791.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-17",9,7.7,362.3,,0.002,0.001,336.32,0.059,0.055,0.0489,5657.591,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-18",8,7.36,360.37,,0.002,0.001,331.266,0.0593,0.051,0.0278,5573.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-19",6,4.7,206.66,,0.001,0.001,195.671,0.059,0.049,0.0657,3294.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-20",4,2.7,110.56,,0.001,0.001,107.478,0.059,0.036,0.1113,1808.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-21",1,0.35,5.95,,0,0.001,7.7,0.06,0.015,0.228,129.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-24",4,2.96,132.38,,0.001,0.001,124.962,0.059,0.035,0.0678,2103.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-27",4,2.7,114.66,,0.001,0.001,110.46,0.0593,0.047,0.0993,1859.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-28",4,2.86,130.72,,0.001,0.001,122.702,0.059,0.038,0.0968,2063.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-05",7,5.71,277.32,,0.001,0.001,257.474,0.059,0.053,0.0634,4330.407,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-06",8,7.42,370.48,,0.002,0.001,340.143,0.059,0.049,0.0261,5725.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-17",5,3.57,164.65,,0.001,0.001,154.826,0.059,0.044,0.1462,2606.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-18",4,2.97,133.84,,0.001,0.001,126.343,0.059,0.042,0.09,2125.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-19",4,3.02,137.82,,0.001,0.001,129.728,0.059,0.041,0.0878,2182.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-21",4,2.7,110.7,,0.001,0.001,107.768,0.059,0.036,0.1115,1814.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-29",3,2.73,114.69,,0.001,0.001,110.347,0.0593,0.044,0.052,1855.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-09-30",3,2.76,114.1,,0.001,0.001,110.464,0.059,0.052,0.0613,1858.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-01",4,2.76,116.34,,0.001,0.001,112.263,0.0593,0.042,0.1438,1889.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-04",4,2.9,124.96,,0.001,0.001,118.952,0.059,0.042,0.174,2001.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-05",4,3.41,155.28,,0.001,0.001,145.442,0.059,0.045,0.051,2445.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-06",4,2.91,120.71,,0.001,0.001,117.007,0.0593,0.042,0.1678,1967.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-12",17,15.92,744.58,,0.003,0.001,688.356,0.059,0.072,0.0238,11581.357,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-13",3,2.75,112.75,,0.001,0.001,109.603,0.059,0.051,0.061,1844.469,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-14",4,2.96,135.8,,0.001,0.001,127.652,0.059,0.04,0.0998,2148.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-15",4,3.26,136.32,,0.001,0.001,131.661,0.0593,0.042,0.0568,2215.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-16",4,2.81,115.55,,0.001,0.001,112.736,0.059,0.04,0.1785,1896.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-02",4,2.75,115.73,,0.001,0.001,111.544,0.0593,0.037,0.1058,1877.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-04",4,2.71,113.15,,0.001,0.001,109.247,0.059,0.037,0.178,1839.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-05",4,3,128.52,,0.001,0.001,123.972,0.059,0.042,0.0985,2086.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-01",8,6.16,262.84,,0.001,0.001,250.382,0.0591,0.08,0.0784,4213.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-06",4,2.9,124.26,,0.001,0.001,124.098,0.059,0.048,0.1118,2087.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-14",10,8.83,405.54,,0.002,0.001,389.184,0.059,0.051,0.0402,6551.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-17",3,2.78,114.86,,0.001,0.001,114.83,0.059,0.048,0.0537,1932.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-25",3,1.57,57.56,,0,0.001,59.973,0.059,0.034,0.254,1009.899,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-29",4,2.76,125.96,,0.001,0.001,122.242,0.0593,0.037,0.1993,2056.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-30",5,3.2,135.24,,0.001,0.001,133.94,0.0594,0.049,0.1932,2252.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-04",3,1.58,57.54,,0,0.001,59.98,0.059,0.047,0.2843,1008.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-05",4,2.6,107.38,,0.001,0.001,106.372,0.0593,0.036,0.1518,1788.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-06",4,2.6,106.62,,0.001,0.001,106.484,0.0595,0.038,0.1558,1790.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-07",4,2.6,107.13,,0.001,0.001,106.795,0.059,0.039,0.1515,1796.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-08",4,2.62,106.66,,0.001,0.001,107.272,0.059,0.042,0.1763,1805.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-09",5,4.2,192.06,,0.001,0.001,185.794,0.059,0.048,0.0602,3127.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-10",5,3.95,183.04,,0.001,0.001,176.056,0.059,0.045,0.0658,2962.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-11",4,2.7,110.7,,0.001,0.001,110.5,0.059,0.038,0.116,1860.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-16",10,8.68,398.12,,0.002,0.001,378.916,0.0592,0.048,0.0489,6376.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-23",10,8.68,398.12,,0.002,0.001,379.244,0.059,0.05,0.0464,6380.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-24",10,9.4,441.6,,0.002,0.001,417.32,0.059,0.043,0.0244,7021.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-25",2,1.53,65.49,,0,0.001,63.344,0.059,0.017,0.052,1065.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-10",4,2.7,121.4,,0.001,0.001,118.768,0.059,0.036,0.1005,1997.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-12",4,2.74,113.12,,0.001,0.001,112.91,0.059,0.038,0.0965,1900.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-30",4,2.82,136.38,,0.001,0.001,129.836,0.059,0.039,0.0895,2185.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-07-31",4,2.96,132.24,,0.001,0.001,128.718,0.059,0.039,0.07,2165.793,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-13",4,2.81,117.22,,0.001,0.001,117.019,0.0593,0.039,0.1015,1968.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-14",7,6.23,302.75,,0.001,0.001,287.152,0.059,0.054,0.0504,4830.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-15",6,4.98,237.37,,0.001,0.001,226.646,0.059,0.043,0.0507,3814.556,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-16",4,2.63,107.97,,0.001,0.001,108.124,0.0593,0.032,0.1095,1820.757,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-17",9,7.68,362.79,,0.002,0.001,345.784,0.059,0.055,0.0467,5821.089,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-18",8,7.4,361.81,,0.002,0.001,342.276,0.0591,0.052,0.0264,5760.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-19",6,4.93,218.94,,0.001,0.001,212.704,0.059,0.047,0.058,3579.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-20",4,2.68,110.52,,0.001,0.001,110.444,0.0593,0.034,0.101,1858.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-21",4,2.93,121.89,,0.001,0.001,120.463,0.059,0.033,0.068,2026.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-24",4,2.95,130.62,,0.001,0.001,128.036,0.0593,0.035,0.0658,2154.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-27",4,2.66,114.62,,0.001,0.001,112.986,0.059,0.046,0.0875,1902.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-28",4,2.85,130.99,,0.001,0.001,126.117,0.059,0.037,0.0908,2121.653,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-05",7,6.1,296.2,,0.001,0.001,281.276,0.059,0.048,0.0357,4732.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-06",8,7.4,368.9,,0.002,0.001,349.12,0.059,0.05,0.0259,5875.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-17",4,2.81,124.19,,0.001,0.001,121.984,0.0593,0.041,0.1203,2052.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-18",4,2.75,121.47,,0.001,0.001,118.981,0.0593,0.043,0.1095,2002.457,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-19",4,2.73,122.8,,0.001,0.001,119.477,0.0593,0.035,0.145,2010.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-21",4,2.7,110.7,,0.001,0.001,111.166,0.0593,0.036,0.1063,1871.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-29",3,2.71,113.91,,0.001,0.001,112.93,0.059,0.043,0.0493,1901.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-09-30",3,2.73,112.96,,0.001,0.001,113.099,0.059,0.052,0.06,1902.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-01",4,2.75,115.06,,0.001,0.001,114.872,0.059,0.044,0.139,1932.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-04",4,2.9,123.15,,0.001,0.001,122.06,0.0593,0.044,0.1903,2055.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-05",4,3.13,139.47,,0.001,0.001,136.365,0.059,0.041,0.0813,2295.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-06",4,2.9,120.32,,0.001,0.001,120.103,0.059,0.041,0.1568,2021.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-12",3,2.78,114.86,,0.001,0.001,114.34,0.059,0.047,0.053,1925.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-13",17,15.81,739.88,,0.004,0.001,705.044,0.059,0.072,0.0283,11865.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-14",4,2.76,125.48,,0.001,0.001,121.46,0.059,0.039,0.1043,2044.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-15",4,3,124.08,,0.001,0.001,124.04,0.059,0.043,0.0963,2086.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-16",4,2.8,116.95,,0.001,0.001,116.455,0.0593,0.037,0.1938,1960.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-02",2,0.65,13.45,,0,0.001,17.86,0.059,0.035,0.3065,300.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-04",1,0.45,4.5,,0,0.001,8.91,0.059,0.031,0.419,149.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-05",4,2.96,127.12,,0.001,0.001,126.612,0.059,0.04,0.094,2129.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-01",4,3.23,137.01,,0.001,0.001,135.637,0.059,0.039,0.0575,2282.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-15",10,8.81,402.29,,0.002,0.001,412.658,0.059,0.049,0.0369,6943.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-17",1,0.1,0.1,,0,0.001,0.7,0.06,0,0.069,11.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-04-30",2,0.77,0.77,,0,0.001,9.244,0.0595,0.024,0.315,155.362,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-01",3,2,90.36,,0,0.001,92.012,0.059,0.021,0.122,1547.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-02",1,0.42,0.42,,0,0.001,5.628,0.059,0.015,0.31,94.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-29",4,2.9,133.57,,0.001,0.001,136.095,0.059,0.039,0.1328,2290.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-30",5,3.17,131.29,,0.001,0.001,138.366,0.0592,0.044,0.1248,2327.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-10",4,2.71,112.67,,0.001,0.001,117.304,0.059,0.045,0.083,1973.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-25",10,8.7,397.3,,0.002,0.001,403.56,0.0591,0.051,0.0416,6790.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-26",10,9.4,439.2,,0.002,0.001,441.82,0.059,0.043,0.0247,7433.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-27",1,0.63,22.05,,0,0.001,24.318,0.059,0.015,0.072,409.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-15",1,0.03,0.03,,0,0,0.147,0.059,0,0.001,2.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-30",4,2.8,125.8,,0.001,0.001,129.63,0.059,0.039,0.0905,2181.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-07-31",4,2.93,129.69,,0.001,0.001,133.555,0.059,0.038,0.0765,2247.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-13",4,2.8,113.28,,0.001,0.001,120.82,0.0593,0.041,0.1018,2032.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-14",7,6.23,305.55,,0.002,0.001,305.614,0.059,0.057,0.048,5142.451,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-15",6,4.98,239.1,,0.001,0.001,241.765,0.059,0.042,0.0453,4069.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-16",4,2.67,106.51,,0.001,0.001,113.821,0.059,0.034,0.1085,1916.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-17",9,7.68,358.28,,0.002,0.001,363.155,0.059,0.063,0.0361,6109.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-18",8,7.41,367.41,,0.002,0.001,367.668,0.059,0.057,0.0266,6185.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-19",6,4.41,191.45,,0.001,0.001,199.032,0.059,0.054,0.0738,3350.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-20",4,2.7,109.66,,0.001,0.001,116.137,0.059,0.045,0.078,1954.957,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-24",3,2.75,117.53,,0.001,0.001,122.137,0.0593,0.045,0.0483,2055.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-27",3,2.73,119.89,,0.001,0.001,124.428,0.059,0.046,0.051,2093.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-28",4,2.83,126.8,,0.001,0.001,129.884,0.059,0.039,0.0908,2185.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-05",7,5.43,248.47,,0.001,0.001,255.197,0.059,0.061,0.0727,4294.222,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-06",8,7.37,368.8,,0.002,0.001,369.874,0.059,0.052,0.0268,6221.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-17",4,2.78,116.02,,0.001,0.001,122.852,0.059,0.051,0.1275,2067.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-18",4,2.73,113.88,,0.001,0.001,119.728,0.0593,0.05,0.0928,2014.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-19",4,2.72,113.15,,0.001,0.001,119.675,0.059,0.04,0.1515,2012.933,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-21",4,2.71,109.75,,0.001,0.001,116.263,0.0593,0.036,0.1445,1957.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-29",3,2.7,108.92,,0.001,0.001,115.924,0.059,0.047,0.0537,1950.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-09-30",3,2.71,109.41,,0.001,0.001,116.545,0.059,0.05,0.0573,1960.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-01",4,2.71,111.67,,0.001,0.001,117.93,0.059,0.048,0.095,1985.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-04",4,2.88,119.1,,0.001,0.001,125.958,0.059,0.042,0.1448,2118.793,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-05",4,3.13,130.92,,0.001,0.001,137.916,0.0593,0.043,0.0775,2320.299,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-12",3,2.75,110.81,,0.001,0.001,118.473,0.059,0.047,0.052,1994.077,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-13",4,2.85,115.71,,0.001,0.001,122.716,0.0593,0.055,0.0513,2064.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-14",14,13.1,609.82,,0.003,0.001,617.38,0.059,0.143,0.0491,10385.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-15",3,2.77,113.35,,0.001,0.001,120.517,0.059,0.044,0.048,2027.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-16",4,2.8,114.05,,0.001,0.001,121.14,0.059,0.033,0.126,2037.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-02",4,2.71,110.64,,0.001,0.001,117.467,0.059,0.033,0.092,1977.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-04",4,2.8,114.56,,0.001,0.001,122.34,0.059,0.035,0.0868,2060.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-05",4,2.95,123.42,,0.001,0.001,130.596,0.059,0.039,0.0855,2196.124,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-01",4,2.71,109.21,,0.001,0.001,116.438,0.059,0.036,0.1045,1960.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-15",10,8.8,403.6,,0.002,0.001,427.064,0.059,0.056,0.0419,7185.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-17",3,2.76,112.92,,0.001,0.001,122.98,0.059,0.056,0.0597,2071.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-29",3,1.64,59.25,,0,0.001,67.398,0.059,0.034,0.159,1134.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-29",4,2.91,133.75,,0.001,0.001,141.298,0.0593,0.045,0.146,2377.627,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-30",4,2.8,113.88,,0.001,0.0008,125.292,0.059,0.051,0.0395,2108.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-29",10,8.63,394.99,,0.002,0.001,413.704,0.059,0.055,0.0593,6959.301,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-06-30",10,9.4,440,,0.002,0.001,455.76,0.0591,0.051,0.0281,7672.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-01",1,0.53,16.96,,0,0.001,20.935,0.059,0.016,0.093,352.609,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-10",4,2.66,120.82,,0.001,0.001,127.096,0.059,0.038,0.1118,2137.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-30",4,2.78,127.12,,0.001,0.001,134.312,0.0593,0.04,0.0908,2261.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-07-31",4,2.91,128.33,,0.001,0.001,137.399,0.059,0.039,0.0813,2312.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-13",4,2.76,113.32,,0.001,0.001,123.684,0.0593,0.042,0.103,2082.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-14",7,6.22,303.5,,0.002,0.001,314.52,0.059,0.06,0.047,5294.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-15",6,4.96,235.15,,0.001,0.001,246.337,0.0592,0.047,0.0485,4143.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-16",4,2.52,101.1,,0.001,0.001,111.394,0.059,0.038,0.135,1873.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-17",9,7.38,344.14,,0.002,0.001,360.622,0.059,0.067,0.0514,6069.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-18",8,7.43,363.46,,0.002,0.001,376.657,0.059,0.059,0.0266,6335.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-19",5,4.2,182.44,,0.001,0.001,194.972,0.0592,0.051,0.0674,3280.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-20",4,2.68,108.64,,0.001,0.001,118.465,0.059,0.047,0.0818,1993.489,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-24",3,2.71,116.2,,0.001,0.001,124.977,0.059,0.043,0.0463,2102.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-27",3,2.72,117.72,,0.001,0.001,126.54,0.059,0.047,0.0507,2130.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-28",4,2.8,127.36,,0.001,0.001,133.956,0.059,0.04,0.0908,2255.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-05",7,5.41,241.45,,0.001,0.001,256.981,0.0591,0.065,0.0726,4323.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-06",8,7.35,363.8,,0.002,0.001,375.515,0.059,0.053,0.0283,6317.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-17",5,3.43,145.36,,0.001,0.001,157.333,0.0592,0.057,0.1368,2646.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-18",3,0.68,0.68,,0,0.001,8.456,0.059,0.032,0.4417,142.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-19",5,2.9,112,,0.001,0.001,122.79,0.0592,0.049,0.1952,2068.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-21",4,2.68,109.32,,0.001,0.001,118.716,0.0593,0.038,0.1098,1998.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-29",3,2.68,110.04,,0.001,0.001,118.816,0.059,0.047,0.0537,1999.808,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-09-30",3,2.68,109.26,,0.001,0.001,118.696,0.059,0.054,0.061,1996.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-01",3,2.3,92.44,,0.001,0.001,101.092,0.059,0.043,0.0653,1700.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-04",4,2.87,117.93,,0.001,0.001,127.802,0.0593,0.043,0.1483,2150.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-05",4,3.12,129.88,,0.001,0.001,140.616,0.059,0.045,0.0778,2364.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-12",3,2.71,111.27,,0.001,0.001,121.234,0.059,0.05,0.0547,2039.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-13",4,2.81,114.89,,0.001,0.001,125.421,0.0593,0.059,0.0515,2109.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-14",4,2.73,114.67,,0.001,0.001,123.304,0.059,0.04,0.1053,2076.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-15",17,15.55,726.55,,0.004,0.001,754.979,0.0591,0.079,0.0406,12701.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-02",4,2.7,110.44,,0.001,0.001,119.634,0.059,0.035,0.1,2012.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-04",4,2.78,114.32,,0.001,0.001,124.23,0.0593,0.036,0.089,2090.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-05",4,2.93,122.47,,0.001,0.001,132.362,0.059,0.041,0.0875,2228.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-01",8,5.71,239.98,,0.001,0.001,256.887,0.0591,0.073,0.0935,4321.339,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Long Beach Generating Station",341,"4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-04",7,6.45,34,,0.001,0.001,275.065,0.0591,0.137,0.0509,4630.095,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-05",5,4.78,192.56,,0.002,0.001,304.106,0.059,0.012,0.0046,5115.454,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-13",5,4.15,3.72,,0.001,0.001,150.093,0.059,0.064,0.0482,2526.124,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-25",6,4.99,0,,0.001,0.001,111.537,0.0592,0.066,0.0605,1877.263,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-05-31",7,6.6,37,,0.001,0.001,277.76,0.059,0.13,0.0493,4674.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-01",11,8.54,110.5,,0.002,0.001,449.324,0.059,0.016,0.0038,7561.33,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-09",2,1.45,0,,0,0.001,17.04,0.0585,0,0.0025,287.36,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-10",16,15.32,774.64,,0.004,0.001,877.336,0.059,0.131,0.0203,14764.508,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-17",5,4.46,0,,0.001,0.001,115.187,0.059,0.019,0.0162,1938.352,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-24",1,0.57,0,,0,0.001,17.271,0.06,0.003,0.023,290.244,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-25",17,16.4,1003,,0.005,0.001,1084.56,0.0591,0.197,0.0283,18249.64,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-11",4,3.12,0,,0,0.001,55.912,0.0593,0.008,0.0158,940.596,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-12",24,24,4432,,0.014,0.001,2743.8,0.059,0.208,0.0125,46169.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-13",9,8.32,887.92,,0.003,0.001,691.328,0.059,0.028,0.0048,11630.996,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-27",5,4.47,6,,0.001,0.001,167.469,0.059,0.079,0.0466,2819.458,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-28",24,24,5011,,0.015,0.001,2961.9,0.059,0.179,0.0065,49845.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-29",24,24,5453,,0.016,0.001,3152.7,0.059,0.183,0.0063,53050.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-30",17,16.78,3894.56,,0.011,0.001,2208.396,0.059,0.131,0.0068,37163.952,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-02",5,4.02,6,,0.001,0.0008,100.214,0.06,0.044,0.0334,1685.724,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-03",24,24,5461,,0.016,0.001,3160.4,0.059,0.256,0.0138,53178.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-04",9,8.18,912.46,,0.003,0.001,668.92,0.059,0.034,0.0059,11257.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-14",21,20.05,677,,0.005,0.001,1033.215,0.0591,0.121,0.016,17386.62,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-15",24,24,9756,,0.026,0.001,5161.1,0.059,0.277,0.006,86843.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-16",24,24,12985,,0.033,0.001,6521,0.059,0.389,0.0073,109734.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-17",24,24,11757,,0.03,0.001,5939.9,0.059,0.402,0.0079,99950.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-18",24,24,11692,,0.03,0.001,5878.5,0.059,0.403,0.008,98922.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-19",24,24,10039,,0.026,0.001,5175.8,0.059,0.348,0.0075,87093.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-20",24,24,10859,,0.028,0.001,5460.7,0.059,0.371,0.0081,91881.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-21",24,24,6896,,0.019,0.001,3764,0.059,0.234,0.0068,63339.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-22",24,24,5255,,0.016,0.001,3080.6,0.059,0.178,0.0064,51841.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-23",24,24,5521,,0.016,0.001,3178.1,0.059,0.193,0.0067,53480.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-24",24,24,9575,,0.025,0.001,4937.1,0.059,0.341,0.0077,83077.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-25",24,24,9279,,0.024,0.001,4752.4,0.059,0.337,0.0082,79964.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-26",24,24,7701,,0.021,0.001,4135.5,0.059,0.281,0.0074,69588.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-27",24,24,5450,,0.016,0.001,3158.3,0.059,0.19,0.0065,53143.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-28",24,24,4722,,0.014,0.001,2837.1,0.059,0.161,0.0061,47738.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-29",24,24,4541,,0.014,0.001,2753.5,0.059,0.152,0.006,46331.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-30",24,24,2557,,0.01,0.001,1927.2,0.059,0.082,0.005,32427.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-08-31",24,24,4396,,0.014,0.001,2746.6,0.059,0.158,0.0065,46213.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-01",24,24,4291,,0.014,0.001,2724.2,0.059,0.145,0.0058,45838.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-02",24,24,4394,,0.014,0.001,2728.9,0.059,0.147,0.0058,45919.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-03",24,24,2547,,0.01,0.001,1956.2,0.059,0.08,0.0049,32913.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-04",24,24,6051,,0.017,0.001,3407.1,0.059,0.201,0.0065,57329.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-05",24,24,9199,,0.024,0.001,4840.8,0.059,0.336,0.0074,81451.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-06",24,24,10303,,0.027,0.001,5250,0.059,0.349,0.0078,88342.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-07",24,24,8480,,0.023,0.001,4508.4,0.059,0.282,0.0068,75859,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-08",24,23.9,5936.9,,0.017,0.001,3335.69,0.059,0.2,0.0065,56131.67,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-27",21,20.5,1357,,0.007,0.001,1290.05,0.059,0.106,0.0135,21710.55,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-28",24,24,6400,,0.018,0.001,3644.5,0.059,0.211,0.0062,61325.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-29",24,24,5721,,0.017,0.001,3271,0.059,0.194,0.0065,55037.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-09-30",24,24,8497,,0.023,0.001,4496.1,0.059,0.28,0.0068,75656.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-01",24,24,8903,,0.024,0.001,4686.8,0.059,0.295,0.0069,78859.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-02",24,24,7792,,0.021,0.001,4063.2,0.059,0.265,0.0076,68371.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-03",24,24,5070,,0.015,0.001,2938.3,0.059,0.168,0.0064,49441.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-04",24,24,4239,,0.013,0.001,2640.6,0.059,0.137,0.0057,44436.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-05",24,24,6905,,0.019,0.001,3734.6,0.059,0.232,0.0071,62838.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-06",24,24,6778,,0.018,0.001,3648.6,0.059,0.23,0.0073,61391.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-07",24,24,4266,,0.013,0.001,2648.7,0.059,0.142,0.006,44567,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-08",24,24,2936,,0.011,0.001,2108.9,0.059,0.097,0.0053,35486.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-09",24,24,2971,,0.011,0.001,2113.6,0.059,0.098,0.0054,35561.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-10",24,24,2988,,0.011,0.001,2119.7,0.059,0.097,0.0053,35666.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-11",24,24,2887,,0.011,0.001,2083.5,0.059,0.093,0.0053,35058.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-12",24,24,6469,,0.018,0.001,3638.5,0.059,0.213,0.0063,61220.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-13",24,24,8400,,0.022,0.001,4414.7,0.059,0.286,0.0075,74287.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-14",24,24,5647,,0.017,0.001,3275.3,0.059,0.184,0.006,55114.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-15",24,24,7116,,0.02,0.001,3951.5,0.059,0.237,0.0064,66489.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-16",24,24,6337,,0.018,0.001,3573,0.059,0.211,0.0064,60122.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-17",24,24,6858,,0.019,0.001,3786.4,0.059,0.226,0.0066,63712.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-18",24,24,4815,,0.015,0.001,2902.8,0.059,0.163,0.0062,48843.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-19",24,24,6139,,0.017,0.001,3420.9,0.059,0.221,0.0073,57561.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-20",24,24,5154,,0.015,0.001,3043.5,0.059,0.181,0.0065,51209.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-21",24,23.07,4455.54,,0.014,0.001,2682.143,0.059,0.146,0.0058,45133.243,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-17",17,16.47,3053,,0.009,0.001,1878.911,0.0591,0.199,0.022,31616.493,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-18",1,0.97,105.73,,0,0.001,78.764,0.059,0.004,0.006,1325.311,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-18",2,1.68,0,,0,0.001,27.348,0.059,0.006,0.023,461.136,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-19",24,24,5245,,0.016,0.001,3206.3,0.059,0.279,0.0168,53952.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-20",18,17.85,5264.95,,0.015,0.001,2950.135,0.059,0.183,0.0068,49640.71,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-15",11,10.15,156.75,,0.002,0.001,362.285,0.0594,0.035,0.013,6094.725,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-12",10,9.34,136,,0.001,0.001,274.566,0.059,0.024,0.0113,4620.674,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-24",9,7.88,0,,0.001,0.001,287.776,0.059,0.079,0.0326,4845.708,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-06",17,16.03,3314.3,,0.01,0.001,1921.777,0.0591,0.222,0.0291,32338.599,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-07",24,23.35,1429.4,,0.006,0.001,1274.725,0.059,0.056,0.0051,21449.15,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-25",2,1.12,0,,0,0.001,12.184,0.058,0.001,0.008,205.176,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-26",24,24,4937,,0.015,0.001,2872.6,0.059,0.188,0.0076,48336.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-27",24,24,5418,,0.016,0.001,3092.1,0.059,0.186,0.0061,52034.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-28",21,20.95,3499.65,,0.011,0.001,2131.495,0.059,0.121,0.006,35863.425,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-02",20,19.92,889,,0.005,0.001,1063.384,0.059,0.026,0.0051,17897.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-03",24,24,4833,,0.014,0.001,2833.8,0.059,0.166,0.0059,47682.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-04",7,6.03,2108.88,,0.006,0.001,1091.329,0.059,0.073,0.0081,18363.099,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-11",24,23.08,5238,,0.015,0.001,3049.634,0.0591,0.203,0.0075,51316.646,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-12",24,24,5744,,0.016,0.001,3189.5,0.059,0.196,0.0062,53670.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-13",24,24,4187,,0.012,0.001,2461.5,0.059,0.143,0.006,41421.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-14",23,22.37,3926.69,,0.012,0.001,2308.957,0.059,0.134,0.0059,38854.223,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-17",21,20.87,2776,,0.009,0.001,1760.656,0.0591,0.111,0.0078,29627.034,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-18",24,23.82,3131.36,,0.01,0.001,2001.556,0.059,0.107,0.0054,33678.834,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-27",15,13.33,289.26,,0.002,0.001,434.363,0.0591,0.058,0.0158,7309.236,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-28",11,10.5,764,,0.003,0.001,575.75,0.0588,0.048,0.0146,9689.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-29",24,24,3741,,0.011,0.001,2256,0.059,0.128,0.0054,37962.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-30",23,21.66,2680.1,,0.009,0.001,1704.335,0.059,0.117,0.0113,28680.939,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-07-31",24,24,6453,,0.018,0.001,3580.4,0.059,0.26,0.0101,60247.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-01",24,24,9619,,0.025,0.001,4950,0.059,0.334,0.0079,83292.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-02",24,24,1402,,0.006,0.001,1265.5,0.059,0.043,0.004,21291.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-03",24,23.52,5202.44,,0.015,0.001,2910.82,0.059,0.195,0.0066,48980.684,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-12",21,20.02,3721,,0.011,0.001,2164.412,0.0592,0.165,0.0121,36417.706,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-13",24,24,12738,,0.032,0.001,6422.9,0.059,0.451,0.0083,108080.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-14",24,24,9805,,0.026,0.001,5119.7,0.059,0.354,0.0069,86154.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-15",24,24,13310,,0.034,0.001,6646.4,0.059,0.476,0.0084,111837.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-16",24,24,10125,,0.026,0.001,5247.1,0.059,0.366,0.0073,88290.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-17",24,24,12832,,0.033,0.001,6455.3,0.059,0.47,0.0085,108618.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-18",24,24,12693,,0.032,0.001,6340,0.059,0.458,0.0085,106687.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-19",24,24,12951,,0.033,0.001,6486.7,0.059,0.465,0.0084,109154.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-20",24,24,11210,,0.029,0.001,5650.6,0.059,0.391,0.0082,95082.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-21",24,24,7352,,0.02,0.001,3896.1,0.059,0.254,0.007,65556.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-22",24,24,4687,,0.014,0.001,2691.5,0.059,0.159,0.0058,45291.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-23",24,24,5129,,0.015,0.001,2894.5,0.059,0.174,0.006,48704.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-24",24,24,9308,,0.024,0.001,4836.6,0.059,0.336,0.007,81381.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-25",24,24,9146,,0.024,0.001,4708.3,0.059,0.327,0.0075,79229.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-26",24,24,4887,,0.014,0.001,2706,0.059,0.168,0.0067,45534.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-27",1,0.05,1,,0,0.001,1.44,0.059,0,0.003,24.215,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-08-31",3,2.35,0,,0,0.001,40.555,0.0593,0.003,0.0073,683.18,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-01",15,14.08,472.6,,0.003,0.001,553.316,0.0591,0.02,0.0045,9311.644,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-02",24,24,1469,,0.006,0.001,1245.7,0.059,0.046,0.0044,20960.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-03",24,24,1473,,0.006,0.001,1245.1,0.059,0.052,0.005,20953.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-04",24,24,5728,,0.016,0.001,3173.7,0.059,0.202,0.0065,53405.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-05",24,24,9105,,0.024,0.001,4819.1,0.059,0.324,0.0068,81092.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-06",24,24,8932,,0.024,0.001,4737.4,0.059,0.321,0.0068,79713.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-07",24,24,8565,,0.023,0.001,4582.5,0.059,0.304,0.0065,77110.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-08",24,24,6138,,0.017,0.001,3376,0.059,0.21,0.0065,56806.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-09",23,22.9,4330.4,,0.013,0.001,2492.51,0.059,0.147,0.0059,41941.16,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-26",14,12.92,204,,0.002,0.001,325.712,0.0622,0.03,0.0161,5479.601,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-27",24,24,1490,,0.006,0.001,1287.2,0.059,0.045,0.0042,21660.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-28",24,24,6089,,0.017,0.001,3361.3,0.059,0.215,0.0064,56558.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-29",24,24,4994,,0.014,0.001,2808.8,0.059,0.175,0.0063,47264.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-09-30",24,24,9142,,0.024,0.001,4728.4,0.059,0.301,0.0068,79564.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-01",24,24,9925,,0.026,0.001,5099,0.059,0.331,0.007,85800.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-02",24,24,6998,,0.019,0.001,3684.5,0.059,0.236,0.007,61997.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-03",24,24,5191,,0.014,0.001,2871.7,0.059,0.175,0.0064,48325.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-04",24,24,2960,,0.01,0.001,1915.5,0.059,0.094,0.0048,32235.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-05",24,24,6756,,0.018,0.001,3663,0.059,0.227,0.0063,61634.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-06",24,24,5753,,0.016,0.001,3167.9,0.059,0.192,0.0062,53307.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-07",24,24,1427,,0.006,0.001,1235.4,0.059,0.042,0.004,20786.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-08",24,24,1455,,0.006,0.001,1256.3,0.059,0.043,0.004,21137.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-09",24,24,1439,,0.006,0.001,1243.8,0.059,0.042,0.004,20927.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-10",24,24,1441,,0.006,0.001,1246.8,0.059,0.042,0.004,20980.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-11",24,24,1848,,0.007,0.001,1421.7,0.059,0.056,0.0044,23922.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-12",24,24,5751,,0.016,0.001,3209.5,0.059,0.19,0.0058,54009.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-13",24,24,4920,,0.014,0.001,2802.7,0.059,0.164,0.0058,47159,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-14",24,24,4864,,0.014,0.001,2791.4,0.059,0.161,0.0056,46972,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-15",24,24,6717,,0.019,0.001,3667.9,0.059,0.223,0.006,61719.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-16",24,24,6663,,0.018,0.001,3634.3,0.059,0.222,0.006,61151.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-17",24,24,6632,,0.018,0.001,3630.9,0.059,0.22,0.0059,61096.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-18",24,22.85,2930.09,,0.01,0.001,1899.058,0.059,0.098,0.0052,31957.802,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-19",24,24,3566,,0.011,0.001,2197.9,0.059,0.117,0.0052,36985,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-20",24,24,3265,,0.01,0.001,2037.3,0.059,0.106,0.0051,34281.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-21",23,22.05,2547.3,,0.009,0.001,1716.77,0.059,0.083,0.0047,28892.165,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-04",23,22.32,2866,,0.009,0.001,1836.648,0.059,0.113,0.008,30905.888,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-05",24,24,3572,,0.011,0.001,2210.7,0.059,0.117,0.0052,37196.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-06",24,24,1423,,0.006,0.001,1276.4,0.059,0.043,0.004,21477.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-07",1,0.35,11.9,,0,0.001,12.145,0.059,0,0.004,204.19,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Ormond Beach Power, LLC.",350,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-05",8,8,0,,0,0.001,85.9,0.0596,0.021,0.0363,1444.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-06",24,24,540,,0.003,0.001,616.5,0.0593,0.04,0.0082,10371.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-07",17,17,254,,0.002,0.001,337.2,0.0591,0.023,0.0089,5674.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-12",7,7,0,,0,0.001,63.8,0.0593,0.019,0.0457,1072.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-13",24,24,443,,0.003,0.001,549.5,0.0592,0.036,0.0087,9248.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-14",24,24,536,,0.003,0.001,606.3,0.0593,0.059,0.0116,10199.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-15",24,24,394,,0.003,0.001,516.2,0.0593,0.033,0.0078,8683,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-16",2,2,15,,0,0.001,21.1,0.0585,0.002,0.0285,355.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-04",11,11,0,,0.001,0.001,103.7,0.0593,0.026,0.0326,1744.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-03",17,17,109,,0.001,0.001,251.8,0.0594,0.031,0.0208,4236.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-04",18,18,267,,0.002,0.001,366.3,0.0591,0.028,0.0092,6165.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-20",10,10,5,,0.001,0.001,103.9,0.0595,0.026,0.0342,1748.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-21",24,24,361,,0.002,0.001,456.5,0.0594,0.035,0.0091,7681.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-22",3,3,31,,0,0.001,41.1,0.0583,0.004,0.022,692,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-23",10,10,14,,0.001,0.001,115.4,0.0593,0.021,0.0267,1942.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-24",24,24,713,,0.004,0.001,807.5,0.0593,0.041,0.0067,13583,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-25",20,20,938,,0.005,0.001,940.7,0.059,0.037,0.0048,15827.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-03",19,19,168,,0.002,0.001,326.5,0.0592,0.044,0.0185,5495.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-04",24,24,360,,0.002,0.001,455.7,0.0592,0.038,0.01,7670.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-05",6,6,75,,0.001,0.001,100.7,0.0595,0.009,0.0292,1692.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-23",9,9,1,,0,0.001,91.7,0.0593,0.025,0.0372,1541.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-24",24,24,333,,0.002,0.001,467.3,0.0593,0.037,0.0095,7864.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-25",23,23,353,,0.002,0.001,465.4,0.0594,0.035,0.0105,7829,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-10",21,21,271,,0.002,0.001,360.6,0.0592,0.045,0.0178,6070.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-11",18,18,375,,0.002,0.001,406.9,0.0593,0.034,0.0092,6846.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-16",20,20,133,,0.001,0.001,290.3,0.0592,0.033,0.0162,4887.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-17",23,23,330,,0.002,0.001,453.3,0.0592,0.032,0.0089,7628.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-18",8,8,0,,0,0.001,65.3,0.0591,0.012,0.0273,1101.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-19",24,24,350,,0.002,0.001,464.5,0.0594,0.036,0.0092,7812.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-20",4,4,57,,0,0.001,71.7,0.0595,0.005,0.009,1205.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-26",2,2,0,,0,0.001,15.8,0.0595,0.006,0.0425,266,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-27",24,24,223,,0.002,0.001,388.2,0.0593,0.037,0.0126,6532.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-28",24,24,360,,0.003,0.001,501.1,0.0592,0.037,0.0089,8433.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-29",24,24,368,,0.002,0.001,491.7,0.0592,0.037,0.009,8273.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-30",17,17,293,,0.002,0.001,350.2,0.0592,0.031,0.0098,5892,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-08",9,9,0,,0,0.001,81.2,0.0593,0.018,0.0274,1366.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-09",4,4,11,,0,0.001,40.9,0.0598,0.005,0.014,687.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-12",5,5,0,,0,0.001,48.7,0.059,0.013,0.038,819.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-13",18,18,972,,0.004,0.001,735.7,0.0591,0.064,0.0126,12380.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-16",15,15,51,,0.001,0.001,170.1,0.0593,0.021,0.0198,2862,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-17",22,22,1014,,0.004,0.001,804.6,0.0592,0.043,0.011,13535.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-18",12,12,172,,0.001,0.001,237,0.0593,0.021,0.0148,3987.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-19",24,24,541,,0.003,0.001,576,0.0592,0.037,0.0079,9693.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-20",24,24,838,,0.004,0.001,748.9,0.0592,0.043,0.008,12603.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-21",24,24,987,,0.004,0.001,826.4,0.0592,0.039,0.0072,13906.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-22",24,24,974,,0.004,0.001,840.2,0.0592,0.04,0.0072,14138.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-23",24,24,1145,,0.005,0.001,961,0.0592,0.043,0.0065,16168.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-24",23,23,390,,0.003,0.001,498.2,0.0592,0.032,0.0092,8383.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-25",20,20,254,,0.002,0.001,396.7,0.0592,0.027,0.0093,6675,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-26",24,24,515,,0.003,0.001,597.4,0.0591,0.034,0.0074,10053.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-27",24,24,426,,0.003,0.001,535.5,0.0591,0.033,0.0075,9011.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-28",24,24,526,,0.003,0.001,594.8,0.0593,0.043,0.008,10007.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-29",24,24,360,,0.003,0.001,506.1,0.0593,0.034,0.008,8515.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-30",8,8,106,,0.001,0.001,146.5,0.0594,0.01,0.0098,2465.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-02",9,9,5,,0,0.001,95.3,0.0592,0.017,0.0256,1605.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-03",24,24,347,,0.002,0.001,486.7,0.0594,0.033,0.0081,8189.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-04",24,24,395,,0.003,0.001,515.4,0.0592,0.034,0.0078,8672.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-05",24,24,1032,,0.004,0.001,889.6,0.0591,0.053,0.0074,14973,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-06",24,24,1504,,0.006,0.001,1160,0.0591,0.055,0.0065,19521.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-07",24,24,751,,0.004,0.001,731.1,0.0592,0.045,0.0076,12302.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-08",24,24,405,,0.003,0.001,503.9,0.0593,0.033,0.0078,8475.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-09",24,24,360,,0.002,0.001,476,0.0593,0.032,0.008,8009.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-10",10,10,136,,0.001,0.001,176.2,0.0596,0.012,0.0116,2962.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-14",3,3,0,,0,0.001,25.1,0.0593,0.007,0.041,421.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-15",24,24,304,,0.002,0.001,452.1,0.0592,0.034,0.01,7609.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-16",23,23,400,,0.002,0.001,480.6,0.0593,0.031,0.0088,8083.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-17",12,12,144,,0.001,0.001,214,0.0593,0.017,0.0123,3600.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-18",22,22,781,,0.003,0.001,691.9,0.0592,0.034,0.0079,11644.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-24",1,1,0,,0,0.001,4.6,0.059,0.004,0.096,77.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-25",24,24,214,,0.002,0.001,393.7,0.0592,0.034,0.0118,6626.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-26",24,24,682,,0.004,0.001,803.4,0.0591,0.039,0.0061,13515.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-27",24,24,1100,,0.005,0.001,1060.6,0.059,0.045,0.0051,17845.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-28",24,24,412,,0.003,0.001,519.4,0.0593,0.361,0.0546,8738.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-29",24,24,372,,0.003,0.001,502,0.0593,0.038,0.0091,8445.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-09-30",24,24,1021,,0.004,0.001,875.7,0.0592,0.041,0.0068,14735.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-01",24,24,814,,0.004,0.001,770,0.0592,0.041,0.0078,12956.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-02",24,24,242,,0.002,0.001,420.4,0.0593,0.032,0.009,7071.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-03",24,24,240,,0.002,0.001,424.2,0.0594,0.032,0.009,7136.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-04",24,24,391,,0.003,0.001,510,0.0593,0.034,0.0086,8578.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-05",24,24,542,,0.003,0.001,599.2,0.0593,0.038,0.0083,10080.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-06",23,23,221,,0.002,0.001,382.5,0.0594,0.029,0.0099,6434.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-11",9,9,7,,0,0.001,97.6,0.0594,0.015,0.0199,1640,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-12",24,24,299,,0.002,0.001,443,0.0593,0.033,0.0092,7452.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-13",24,24,351,,0.002,0.001,462.3,0.0591,0.035,0.0095,7781.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-14",24,24,352,,0.002,0.001,458.3,0.0592,0.036,0.0098,7713.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-15",24,24,576,,0.003,0.001,576.1,0.0593,0.037,0.0093,9692.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-16",24,24,809,,0.004,0.001,711.4,0.0593,0.037,0.0085,11968.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-17",24,24,1071,,0.004,0.001,868.9,0.0591,0.043,0.0079,14623.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-18",15,15,141,,0.001,0.001,221.7,0.0595,0.019,0.0113,3729.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-17",4,4,0,,0,0.001,25.7,0.0595,0.009,0.0398,432.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"5",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-03",23,23,224,,0.002,0.001,473.8,0.059,0.076,0.019,7967.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-04",23,23,354,,0.003,0.001,520.8,0.059,0.039,0.0091,8758.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-05",1,1,0,,0,0.001,20.6,0.059,0.016,0.092,346.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-06",24,24,186,,0.002,0.001,494.4,0.059,0.164,0.0395,8313.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-07",24,24,313,,0.002,0.001,494.4,0.059,0.042,0.01,8313.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-08",24,24,312,,0.002,0.001,494.4,0.059,0.041,0.0099,8313.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-09",8,8,94,,0.001,0.001,164.8,0.059,0.016,0.0118,2771.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-11",9,9,30,,0.001,0.001,184.5,0.059,0.07,0.0448,3111.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-12",24,24,717,,0.004,0.001,727,0.059,0.067,0.0101,12247.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-13",24,24,337,,0.002,0.001,492,0.059,0.04,0.0097,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-14",24,24,358,,0.003,0.001,510.8,0.059,0.039,0.0092,8613,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-15",24,24,346,,0.003,0.001,510.8,0.059,0.038,0.009,8613,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-16",24,24,455,,0.003,0.001,567,0.059,0.039,0.0086,9558.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-17",24,24,336,,0.002,0.001,492,0.059,0.037,0.009,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-18",24,24,336,,0.002,0.001,492,0.059,0.043,0.0103,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-19",24,24,341,,0.002,0.001,492,0.059,0.037,0.009,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-20",24,24,336,,0.002,0.001,492,0.059,0.038,0.0092,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-21",24,24,337,,0.002,0.001,492,0.059,0.039,0.0094,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-22",24,24,332,,0.002,0.001,492,0.059,0.039,0.0093,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-23",24,24,325,,0.002,0.001,492,0.059,0.041,0.01,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-24",24,24,335,,0.002,0.001,492,0.059,0.041,0.0098,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-25",24,24,335,,0.002,0.001,492,0.059,0.037,0.009,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-26",1,1,1,,0,0.001,20.5,0.059,0.004,0.023,345.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-27",9,9,29,,0.001,0.001,184.5,0.059,0.05,0.0322,3111.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-28",24,24,323,,0.002,0.001,492,0.059,0.053,0.0127,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-29",9,9,38,,0.001,0.001,184.5,0.059,0.033,0.0213,3111.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-30",24,24,357,,0.002,0.001,492,0.059,0.04,0.0095,8296.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-03-31",1,1,1,,0,0.001,20.5,0.059,0.016,0.092,345.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-17",11,11,72,,0.001,0.001,171.1,0.0593,0.023,0.0279,2880.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-18",24,24,336,,0.003,0.001,506.1,0.0595,0.039,0.0092,8514.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-19",24,24,336,,0.003,0.001,500.2,0.0593,0.038,0.009,8416.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-20",8,8,98,,0.001,0.001,147.1,0.0593,0.011,0.0108,2474.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-24",8,8,39,,0.001,0.001,131.9,0.0594,0.019,0.0235,2217.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-25",24,24,314,,0.002,0.001,494.6,0.0593,0.039,0.0094,8322.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-26",7,7,79,,0.001,0.001,124.8,0.0591,0.01,0.021,2100.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-29",8,8,45,,0.001,0.001,136.2,0.0591,0.017,0.0201,2293.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-04-30",24,24,790,,0.004,0.001,841.1,0.0591,0.038,0.0056,14154.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-01",8,8,177,,0.001,0.001,193.2,0.0589,0.01,0.0091,3252.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-05",3,3,0,,0,0.001,24.6,0.0593,0.01,0.0513,413.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-06",24,24,696,,0.004,0.001,792.8,0.0591,0.403,0.0708,13339.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-07",24,24,927,,0.005,0.001,935.7,0.059,0.042,0.0054,15745.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-08",24,24,592,,0.003,0.001,673,0.0593,0.034,0.006,11321.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-09",24,24,803,,0.004,0.001,790.5,0.0591,0.04,0.0061,13301.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-10",7,7,146,,0.001,0.001,164.8,0.0591,0.01,0.0104,2774.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-20",9,9,40,,0.001,0.001,127.7,0.0593,0.021,0.028,2149.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-21",24,24,554,,0.003,0.001,664,0.0592,0.039,0.0076,11170.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-25",3,3,0,,0,0.001,17.7,0.059,0.014,0.1053,298.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-26",24,24,1173,,0.006,0.001,1090.7,0.0591,0.056,0.0079,18352.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-27",24,24,844,,0.004,0.001,867.8,0.0592,0.043,0.0062,14602.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-28",24,24,556,,0.003,0.001,621.9,0.0591,0.039,0.009,10466.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-03",15,15,101,,0.001,0.001,233.3,0.0593,0.029,0.0211,3925.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-04",24,24,334,,0.003,0.001,540.1,0.0593,0.04,0.0088,9088.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-05",8,8,98,,0.001,0.001,157.2,0.0591,0.011,0.0113,2646.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-10",11,11,26,,0.001,0.001,129.4,0.0595,0.024,0.0363,2176.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-11",24,24,357,,0.003,0.001,518.7,0.0593,0.038,0.0088,8728.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-12",1,1,1,,0,0.001,1.2,0.058,0,0.047,20.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-23",23,23,210,,0.002,0.001,410.7,0.0594,0.043,0.02,6905.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-24",11,11,141,,0.001,0.001,229.2,0.059,0.014,0.0092,3859.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-10",15,15,202,,0.002,0.001,322.1,0.0593,0.03,0.0203,5421.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-11",24,24,1296,,0.006,0.001,1236.8,0.059,0.054,0.0053,20815.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-12",24,24,924,,0.004,0.001,868.3,0.0591,0.041,0.0059,14611.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-13",24,24,887,,0.004,0.001,837,0.0592,0.042,0.0066,14083.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-14",8,8,33,,0.001,0.001,123.4,0.0593,0.013,0.0138,2077.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-15",24,24,337,,0.003,0.001,518.9,0.0593,0.041,0.0094,8728.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-16",23,23,308,,0.002,0.001,487.2,0.0592,0.036,0.0093,8199.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-17",18,18,216,,0.002,0.001,374.6,0.0592,0.03,0.0104,6305.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-18",24,24,651,,0.004,0.001,796.6,0.0593,0.042,0.0069,13401.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-19",24,24,817,,0.005,0.001,910.6,0.0591,0.042,0.0058,15322.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-20",24,24,336,,0.003,0.001,528,0.0594,0.038,0.0087,8880.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-21",24,24,336,,0.003,0.001,510.4,0.0592,0.038,0.0089,8589.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-22",7,7,85,,0.001,0.001,127.2,0.0597,0.01,0.0121,2138.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-26",15,15,123,,0.001,0.001,262.9,0.0591,0.029,0.0179,4424.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-27",24,24,337,,0.003,0.001,546.7,0.0592,0.034,0.0073,9198.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-28",24,24,388,,0.003,0.001,614.2,0.0592,0.034,0.0067,10336.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-29",24,24,992,,0.005,0.001,1046.7,0.059,0.048,0.0057,17612.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-30",24,24,1002,,0.005,0.001,939.7,0.0593,0.068,0.0079,15811,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-07-31",24,24,1127,,0.005,0.001,990.6,0.0592,0.052,0.0064,16665.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-01",24,24,622,,0.003,0.001,691.7,0.0591,0.154,0.0273,11641.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-02",24,24,576,,0.003,0.001,665.4,0.0592,0.034,0.006,11198.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-03",24,24,578,,0.003,0.001,669.2,0.0592,0.276,0.0487,11258.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-04",24,24,1611,,0.006,0.001,1241.4,0.059,0.065,0.006,20889.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-05",24,24,1059,,0.005,0.001,1046.1,0.059,0.043,0.005,17602.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-08",10,10,42,,0.001,0.001,152.6,0.0594,0.019,0.0225,2568.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-09",24,24,341,,0.003,0.001,519.1,0.0592,0.039,0.0091,8734,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-10",24,24,336,,0.003,0.001,511.1,0.0592,0.034,0.0079,8603.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-11",24,24,336,,0.003,0.001,512.3,0.0593,0.034,0.008,8620.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-12",24,24,690,,0.004,0.001,804,0.0592,0.049,0.0072,13530.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-13",24,24,814,,0.004,0.001,870,0.0591,0.046,0.0065,14638.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-14",24,24,1395,,0.006,0.001,1121.8,0.0592,0.057,0.007,18878.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-15",24,24,1543,,0.006,0.001,1212.6,0.0591,0.061,0.006,20407.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-16",24,24,1393,,0.006,0.001,1147.7,0.059,0.055,0.0059,19313.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-17",24,24,1686,,0.007,0.001,1337.3,0.0592,0.074,0.0065,22499.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-18",24,24,1905,,0.007,0.001,1444.6,0.0591,0.078,0.0063,24305.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-19",24,24,1235,,0.005,0.001,1083.9,0.0591,0.058,0.0062,18241.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-20",24,24,1168,,0.005,0.001,1046.6,0.0592,0.302,0.0487,17611.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-21",23,23,1218,,0.005,0.001,1053.7,0.0591,0.054,0.006,17731.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-24",15,15,47,,0.001,0.001,183.8,0.0593,0.02,0.0151,3095.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-28",17,17,286,,0.002,0.001,407.7,0.0591,0.037,0.018,6862,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-29",23,23,518,,0.003,0.001,625.1,0.0592,0.037,0.0073,10517.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-02",10,10,39,,0.001,0.001,135.2,0.0593,0.02,0.0297,2274.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-03",24,24,893,,0.005,0.001,922.2,0.059,0.045,0.006,15513,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-04",24,24,1080,,0.005,0.001,1057.9,0.059,0.058,0.0063,17799,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-05",24,24,843,,0.004,0.001,794.2,0.0591,0.042,0.0065,13367.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-06",24,24,1234,,0.005,0.001,1007.8,0.0591,0.041,0.0052,16960.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-07",24,24,793,,0.004,0.001,761.2,0.0591,0.038,0.006,12806.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-08",22,22,519,,0.003,0.001,575.5,0.0591,0.033,0.0071,9682.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-28",17,17,251,,0.002,0.001,344.2,0.0592,0.018,0.0109,5793.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-29",22,22,541,,0.003,0.001,587.2,0.0592,1.073,0.2156,9879.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-09-30",18,18,1146,,0.005,0.001,891,0.0586,0.056,0.0081,14994.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-01",24,24,1198,,0.005,0.001,997.8,0.0591,0.073,0.0089,16790.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-02",24,24,576,,0.003,0.001,653.7,0.0592,0.042,0.0077,10999.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-03",24,24,577,,0.003,0.001,657.5,0.0592,0.036,0.0066,11064.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-04",24,24,762,,0.004,0.001,764.5,0.0592,0.044,0.0068,12864.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-05",24,24,1030,,0.005,0.001,928,0.0592,0.055,0.0073,15612.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-06",24,24,1084,,0.006,0.001,1097.7,0.059,0.049,0.0053,18468.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-07",6,6,206,,0.001,0.001,202.1,0.059,0.012,0.0107,3401.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-11",10,10,47,,0.001,0.001,145.3,0.0593,0.019,0.02,2446.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-12",24,24,724,,0.004,0.001,780.4,0.059,0.045,0.0069,13135.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-13",24,24,579,,0.004,0.001,706.3,0.0593,0.039,0.0065,11880,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-14",24,24,853,,0.005,0.001,898.3,0.0591,0.048,0.0062,15118.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-15",24,24,1333,,0.006,0.001,1207,0.059,0.054,0.0054,20311.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-16",24,24,1156,,0.005,0.001,1040.3,0.0591,0.056,0.0062,17506.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-17",24,24,1441,,0.006,0.001,1199.3,0.0591,0.063,0.0062,20183.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-18",15,15,351,,0.002,0.001,419.1,0.0592,0.022,0.0076,7051.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-26",23,23,387,,0.003,0.001,535.6,0.0592,0.04,0.013,9011.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-27",9,9,188,,0.001,0.001,221.9,0.0592,0.012,0.0069,3735.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-02",16,16,206,,0.002,0.001,325.7,0.0594,0.031,0.0163,5480.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-03",24,24,627,,0.004,0.001,706.8,0.0592,0.037,0.0062,11891.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-04",24,24,622,,0.004,0.001,708.2,0.0593,0.035,0.006,11917.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-05",15,15,375,,0.002,0.001,394.8,0.0592,0.021,0.0068,6644,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-06",7,7,0,,0,0.001,51.7,0.0599,0.011,0.0279,867.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-07",5,5,0,,0,0.001,61,0.0592,0.008,0.017,1027.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-26",21,21,297,,0.002,0.001,439.3,0.0591,0.038,0.0154,7397.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-27",13,13,290,,0.002,0.001,328.3,0.0593,0.017,0.0067,5522,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-21",8,8,0,,0,0.001,84,0.0596,0.018,0.0301,1411.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-23",9,9,16,,0.001,0.001,109.1,0.0591,0.016,0.0231,1838.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-24",24,24,312,,0.003,0.001,518.9,0.0593,0.035,0.008,8729.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-25",24,24,301,,0.002,0.001,495.2,0.0593,0.034,0.0084,8330.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-27",10,10,25,,0.001,0.001,119.6,0.0595,0.018,0.0296,2013.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-28",19,19,183,,0.002,0.001,370.3,0.0593,0.027,0.0091,6232.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-29",24,24,231,,0.002,0.001,453.3,0.0594,0.031,0.0085,7626,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"6",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-06",4,4,0,,0,0.001,77.3,0.0593,0.063,0.0958,1301.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-07",24,24,1484,,0.007,0.001,1424.5,0.059,0.249,0.0452,23971.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-08",24,24,3058,,0.011,0.001,2241.4,0.059,0.039,0.0021,37715.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-24",6,6,0,,0.001,0.001,119.9,0.0597,0.14,0.1287,2017,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-25",20,20,100,,0.003,0.001,547,0.0591,0.223,0.0523,9207.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-26",8,8,0,,0.001,0.001,183.3,0.0591,0.153,0.0969,3086.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-27",11,11,181,,0.002,0.001,369.9,0.0591,0.231,0.0767,6224.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-11",17,17,105,,0.002,0.001,464.8,0.0592,0.071,0.0241,7820.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-12",24,24,3952,,0.014,0.001,2759.8,0.059,0.084,0.0034,46437.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-13",24,24,5011,,0.016,0.001,3245.6,0.059,0.128,0.0038,54617.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-14",2,2,200,,0.001,0.001,141.2,0.059,0.003,0.0025,2376.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-18",8,8,0,,0.001,0.001,186.9,0.059,0.218,0.1365,3144.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-19",24,24,2430,,0.01,0.001,1940.8,0.059,0.285,0.0439,32655.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-20",24,24,3816,,0.013,0.001,2668.3,0.059,0.083,0.0036,44896.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-21",2,2,171,,0.001,0.001,122.2,0.059,0.002,0.003,2056.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-28",1,1,0,,0,0.001,1.4,0.059,0.001,0.044,23.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-29",24,24,1011,,0.006,0.001,1184.3,0.0591,0.469,0.0833,19928.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-30",24,24,5513,,0.018,0.001,3585,0.059,0.165,0.005,60326.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-07-31",24,24,5955,,0.019,0.001,3785.7,0.059,0.159,0.0046,63702.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-01",24,24,4795,,0.016,0.001,3191.9,0.059,0.095,0.0035,53712.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-02",24,24,3131,,0.012,0.001,2294.2,0.059,0.05,0.0026,38605.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-03",24,24,4271,,0.015,0.001,2937,0.059,0.117,0.0048,49417.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-04",2,2,212,,0.001,0.001,156.6,0.059,0.004,0.003,2635.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-05",17,17,310,,0.003,0.001,608.3,0.0591,0.429,0.1242,10237.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-06",24,24,4300,,0.015,0.001,2909.7,0.059,0.12,0.0048,48966.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-12",8,8,0,,0.001,0.001,181,0.0593,0.183,0.114,3046.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-13",24,24,4012,,0.014,0.001,2710.1,0.059,0.148,0.0075,45601.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-14",24,24,5907,,0.019,0.001,3708.7,0.059,0.184,0.005,62409.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-15",24,24,6646,,0.021,0.001,4113.2,0.059,0.183,0.0048,69218.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-16",24,24,6162,,0.02,0.001,3872.4,0.059,0.145,0.004,65158.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-17",24,24,7317,,0.023,0.001,4464,0.059,0.187,0.0045,75114.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-18",24,24,7475,,0.023,0.001,4546.5,0.059,0.193,0.0046,76506.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-19",24,24,6443,,0.02,0.001,3995.9,0.059,0.158,0.004,67238.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-20",24,24,5854,,0.019,0.001,3704.5,0.059,0.131,0.0039,62333.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-21",24,24,5863,,0.019,0.001,3712.2,0.059,0.133,0.0039,62468.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-22",24,24,4444,,0.015,0.001,2954.4,0.059,0.081,0.003,49713.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-23",24,24,5662,,0.018,0.001,3611.3,0.059,0.121,0.0036,60769.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-24",24,24,6363,,0.02,0.001,3980.5,0.059,0.147,0.0041,66979.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-25",24,24,5813,,0.019,0.001,3690.5,0.059,0.123,0.0038,62100.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-26",24,24,5181,,0.017,0.001,3356.2,0.059,0.101,0.0035,56476.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-27",24,24,5097,,0.017,0.001,3310.3,0.059,0.108,0.0038,55699.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-28",24,24,4820,,0.016,0.001,3149.2,0.059,0.101,0.0037,52992.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-29",13,13,2158,,0.007,0.001,1454.5,0.059,0.037,0.0031,24473.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-03",6,6,0,,0.001,0.001,126.3,0.0592,0.105,0.0945,2127.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-04",24,24,1074,,0.006,0.001,1190.5,0.0592,0.473,0.0889,20029.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-05",24,24,5627,,0.018,0.001,3569.8,0.059,0.135,0.004,60067.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-06",24,24,6765,,0.021,0.001,4164.9,0.059,0.161,0.0042,70081.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-07",24,24,5082,,0.017,0.001,3323.4,0.059,0.077,0.0028,55919.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-08",24,24,4682,,0.016,0.001,3117.9,0.059,0.09,0.0034,52466.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-09",2,2,168,,0.001,0.001,119.9,0.059,0.002,0.003,2018.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-26",9,9,0,,0.001,0.001,188.6,0.059,0.197,0.1179,3177.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-27",24,24,851,,0.006,0.001,1091.2,0.059,0.414,0.0619,18363,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-28",24,24,4044,,0.014,0.001,2840.7,0.059,0.098,0.0041,47798.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-29",24,24,4609,,0.016,0.001,3176.7,0.059,0.103,0.0038,53453.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-09-30",24,24,4644,,0.016,0.001,3173.1,0.059,0.099,0.0036,53394.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-01",24,24,5864,,0.019,0.001,3713.8,0.059,0.129,0.0037,62495.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-02",24,24,5247,,0.017,0.001,3394.5,0.059,0.115,0.0037,57118.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-03",24,24,4302,,0.015,0.001,2898.3,0.059,0.097,0.0038,48766.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-04",8,8,1276,,0.004,0.001,874.2,0.059,0.025,0.0034,14711.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-06",13,13,43,,0.002,0.001,358,0.059,0.122,0.0468,6025,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-07",24,24,2962,,0.011,0.001,2183.5,0.059,0.059,0.0033,36743,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-08",5,5,498,,0.002,0.001,371.5,0.0592,0.01,0.0036,6250,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-14",3,3,0,,0,0.001,58.6,0.059,0.044,0.0857,987.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-15",24,24,2222,,0.009,0.001,1815.2,0.0591,0.385,0.0567,30542.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-16",24,24,5144,,0.017,0.001,3329.8,0.059,0.131,0.0042,56029.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-17",24,24,5173,,0.017,0.001,3341.9,0.059,0.114,0.0038,56233.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-18",2,2,203,,0.001,0.001,156.5,0.059,0.004,0.0035,2633.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","AES Redondo Beach",356,"8",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,,,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-05",10,8.9,678.02,,0.002,0.001,423.628,0.059,0.171,0.0683,7126.958,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-06",20,19.75,2465.5,,0.006,0.001,1210.3,0.059,0.125,0.0197,20368.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-07",21,20.37,3069.89,,0.007,0.001,1390.338,0.059,0.058,0.0055,23396.608,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-08",19,18.35,2951.98,,0.007,0.001,1348.766,0.059,0.076,0.0122,22693.856,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-09",19,18.07,3521.4,,0.008,0.001,1560.659,0.059,0.077,0.0093,26259.362,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-10",17,16.09,2204.36,,0.005,0.001,1072.494,0.0591,0.075,0.0125,18048.311,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-11",18,16.5,1723.3,,0.005,0.001,924.964,0.059,0.054,0.0154,15563.362,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-12",18,16.12,1644.46,,0.004,0.001,888.484,0.0591,0.05,0.0146,14951.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-14",9,8.06,1030.6,,0.003,0.001,519.476,0.059,0.159,0.063,8741.962,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-16",13,12.18,1735.72,,0.004,0.001,840.422,0.0591,0.187,0.0517,14141.488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-18",7,5.98,725.48,,0.002,0.001,375.512,0.059,0.137,0.0796,6319.792,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-19",8,7.1,1230.9,,0.003,0.001,568.08,0.059,0.08,0.0398,9558,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-20",18,16.95,3104.01,,0.007,0.001,1384.747,0.059,0.085,0.0128,23302.167,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-21",7,5.23,442.73,,0.001,0.001,265.534,0.0591,0.055,0.0436,4468.998,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-22",23,21.67,4561.06,,0.01,0.001,1956.306,0.059,0.094,0.0096,32916.822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-23",4,2.75,432.1,,0.001,0.001,210.815,0.059,0.025,0.0403,3546.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-28",1,0.63,0.63,,0,0.001,16.38,0.059,0.023,0.167,275.751,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-29",20,19.62,3327.44,,0.008,0.001,1540.212,0.059,0.249,0.038,25917.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-30",2,0.93,8.73,,0,0.001,28.134,0.0595,0.047,0.201,472.779,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-03",16,15.16,2095.47,,0.005,0.001,1016.54,0.0591,0.175,0.0485,17103.255,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-04",24,24,4992,,0.011,0.001,2176.1,0.059,0.075,0.0041,36616.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-05",24,24,6007,,0.013,0.001,2502.5,0.059,0.086,0.0041,42108.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-06",24,24,3520,,0.008,0.001,1620.9,0.059,0.055,0.004,27275.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-07",24,24,3810,,0.009,0.001,1729,0.059,0.061,0.0042,29095.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-08",2,1.13,118.28,,0,0.001,59.711,0.059,0.004,0.032,1004.129,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-11",9,8.95,1039.1,,0.003,0.001,553.7,0.059,0.22,0.0811,9315.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-12",24,24,4395,,0.01,0.001,1957.8,0.059,0.07,0.0042,32948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-13",24,24,4158,,0.009,0.001,1847.1,0.059,0.068,0.0043,31075.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-14",24,24,5362,,0.012,0.001,2286.2,0.059,0.088,0.0045,38468.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-15",1,0.87,135.72,,0,0.001,63.51,0.059,0.005,0.01,1068.621,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-17",21,20.18,3291.54,,0.008,0.001,1497.104,0.059,0.107,0.0181,25194.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-18",24,24,4902,,0.011,0.001,2116.8,0.059,0.089,0.005,35621.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-19",24,24,5769,,0.012,0.001,2417.4,0.059,0.103,0.005,40676.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-20",24,24,4166,,0.009,0.001,1846.5,0.059,0.078,0.005,31073.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-21",19,17.8,3803.2,,0.008,0.001,1628.87,0.059,0.081,0.0098,27408.175,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-22",24,23.2,4384,,0.01,0.001,1888.96,0.059,0.082,0.0065,31784.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-08",6,5.35,197.7,,0.001,0.001,198.845,0.0592,0.207,0.136,3345.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-09",24,24,4691,,0.01,0.001,2027.4,0.059,0.071,0.0042,34109.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-10",24,24,6367,,0.013,0.001,2619.9,0.059,0.099,0.0045,44084.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-11",24,24,4855,,0.01,0.001,2077.2,0.059,0.08,0.0045,34952.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-12",24,24,6151,,0.013,0.001,2538,0.059,0.102,0.0047,42708.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-13",24,24,5357,,0.011,0.001,2252.1,0.059,0.089,0.0046,37891.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-14",24,24,5370,,0.011,0.001,2239.4,0.059,0.082,0.0043,37682.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-15",24,24,5137,,0.011,0.001,2129.3,0.059,0.073,0.0041,35831.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-16",24,24,4766,,0.01,0.001,2024.9,0.059,0.078,0.0045,34072.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-17",24,24,4827,,0.01,0.001,2054,0.059,0.077,0.0045,34560.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-18",24,24,4667,,0.01,0.001,1988.1,0.059,0.072,0.0043,33458.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-19",24,24,5315,,0.011,0.001,2218.9,0.059,0.076,0.004,37339.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-20",24,24,5010,,0.011,0.001,2102.7,0.059,0.075,0.0043,35381.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-21",1,0.12,8.28,,0,0.001,4.38,0.059,0.002,0.057,73.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-23",4,3.15,79.4,,0.001,0.001,104.922,0.0593,0.187,0.2085,1765.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-16",1,0.53,0.53,,0,0.001,12.932,0.059,0.019,0.174,217.989,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-22",10,9.75,967.25,,0.003,0.001,545.15,0.0591,0.258,0.0937,9171.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-23",7,6.13,674.45,,0.002,0.001,344.662,0.059,0.013,0.0087,5799.913,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-24",9,8.77,1801.01,,0.004,0.001,781.335,0.059,0.082,0.0321,13147.261,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-25",24,24,4767,,0.01,0.001,2033.1,0.059,0.068,0.004,34212,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-26",9,7.4,878.64,,0.002,0.001,451.696,0.059,0.06,0.0363,7598.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-27",8,7.13,757.06,,0.002,0.001,391.972,0.059,0.015,0.0086,6593.444,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-28",18,17.52,3582.52,,0.008,0.001,1566.656,0.059,0.108,0.0188,26364.964,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-29",24,24,4768,,0.01,0.001,2023.6,0.059,0.069,0.004,34053.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-04-30",8,7.18,798.04,,0.002,0.001,393.462,0.059,0.015,0.0073,6620.594,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-06",15,14.25,2587,,0.006,0.001,1151.225,0.059,0.154,0.0371,19370.475,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-07",21,20.4,4125.86,,0.009,0.001,1780.334,0.059,0.07,0.0061,29957.351,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-08",23,22.57,3932.7,,0.009,0.001,1717.257,0.059,0.059,0.0041,28894.862,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-28",15,13.12,1741.17,,0.004,0.001,873.28,0.0591,0.254,0.0591,14691.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-01",18,17.92,3067.64,,0.007,0.001,1388.54,0.059,0.224,0.0378,23363.472,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-02",24,24,4446,,0.01,0.001,1889.5,0.059,0.064,0.004,31796.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-03",23,22.05,3937.65,,0.009,0.001,1695.375,0.059,0.057,0.004,28527.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-04",12,11.03,1720.96,,0.004,0.001,796.019,0.059,0.064,0.0164,13393.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-08",4,3.63,66.63,,0.001,0.001,112.239,0.059,0.176,0.1883,1888.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-09",23,22.33,4481.95,,0.01,0.001,1918.977,0.059,0.108,0.009,32292.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-10",14,12.28,2321.06,,0.005,0.001,1024.772,0.059,0.088,0.0221,17246.608,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-11",14,12.63,2430.57,,0.005,0.001,1067.021,0.059,0.084,0.019,17956.442,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-15",10,9.62,1049.62,,0.003,0.001,559.662,0.059,0.204,0.0789,9415.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-16",1,0.42,68.46,,0,0.001,29.274,0.059,0.003,0.012,492.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-18",8,7.09,795.41,,0.002,0.001,422.604,0.059,0.163,0.0775,7109.141,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-20",8,7.95,1154.95,,0.003,0.001,549.62,0.059,0.065,0.0289,9246.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-21",9,6.44,1041.74,,0.002,0.001,483.352,0.0591,0.063,0.0271,8136.656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-22",13,12.72,2380.08,,0.005,0.001,1047.204,0.059,0.102,0.0258,17620.808,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-23",23,22.13,3881.49,,0.008,0.001,1678.979,0.059,0.058,0.0058,28251.646,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-24",18,17.95,3569.5,,0.008,0.001,1570,0.059,0.062,0.0053,26416.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-25",24,24,4552,,0.01,0.001,1935,0.059,0.065,0.004,32555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-26",15,13.91,2824.59,,0.006,0.001,1222.016,0.0591,0.07,0.0173,20559.363,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-27",24,24,4898,,0.01,0.001,2041.9,0.059,0.069,0.004,34358.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-28",7,6.2,1337.6,,0.003,0.001,556.06,0.059,0.021,0.0076,9357.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-06",13,11.08,1297.7,,0.003,0.001,672.544,0.0591,0.227,0.0744,11318.718,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-07",12,11.28,2264.96,,0.005,0.001,951.233,0.059,0.071,0.0203,16009.245,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-08",20,18.82,3857.12,,0.008,0.001,1628.896,0.059,0.065,0.007,27414.204,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-09",14,13.85,2713.2,,0.006,0.001,1178.98,0.059,0.062,0.0095,19840.365,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-10",24,24,4751,,0.01,0.001,1994.8,0.059,0.067,0.004,33568.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-11",24,24,5094,,0.011,0.001,2107.8,0.059,0.071,0.004,35466.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-12",24,24,4697,,0.01,0.001,1978.1,0.059,0.067,0.004,33284.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-13",24,24,4585,,0.01,0.001,1941,0.059,0.065,0.004,32664.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-14",24,24,4126,,0.009,0.001,1769.6,0.059,0.06,0.004,29774.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-15",24,24,4725,,0.01,0.001,1968.3,0.059,0.067,0.0041,33120.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-16",17,16.23,2612.66,,0.006,0.001,1136.059,0.059,0.038,0.004,19117.199,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-17",6,5.78,955.92,,0.002,0.001,426.656,0.059,0.054,0.0348,7180.066,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-18",24,24,4594,,0.01,0.001,1929.8,0.059,0.067,0.0041,32470.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-19",24,24,4014,,0.009,0.001,1730.8,0.059,0.059,0.0041,29125.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-20",24,24,3846,,0.009,0.001,1685.2,0.059,0.058,0.0041,28357.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-21",24,23.92,4381.2,,0.009,0.001,1867.488,0.059,0.067,0.0043,31421.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-22",10,9.58,1830.86,,0.004,0.001,802.076,0.059,0.053,0.0201,13495.802,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-23",1,0.13,8.19,,0,0.001,4.355,0.059,0.002,0.045,73.333,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-27",18,17.88,2981.88,,0.007,0.001,1362.54,0.059,0.254,0.0482,22930.468,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-28",24,24,4063,,0.009,0.001,1751.3,0.059,0.059,0.004,29470.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-29",24,24,4593,,0.01,0.001,1987.1,0.059,0.068,0.0041,33436.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-30",24,24,4315,,0.009,0.001,1854.6,0.059,0.067,0.0042,31210.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-07-31",24,24,4749,,0.01,0.001,1995.8,0.059,0.078,0.0045,33584.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-01",24,24,3982,,0.009,0.001,1729.4,0.059,0.073,0.005,29097.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-02",24,24,4032,,0.009,0.001,1748.6,0.059,0.063,0.0043,29421.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-03",24,24,4044,,0.009,0.001,1779,0.059,0.06,0.004,29936.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-04",24,24,3840,,0.009,0.001,1692.3,0.059,0.059,0.0041,28470.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-05",7,6.18,710.52,,0.002,0.001,344.366,0.059,0.015,0.0147,5794.278,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-09",14,12.54,1973.99,,0.005,0.001,929.769,0.0591,0.206,0.0591,15643.127,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-10",9,6.75,949.1,,0.002,0.001,444.578,0.0591,0.053,0.0374,7482.466,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-11",11,9.6,1610.3,,0.004,0.001,730.74,0.059,0.104,0.0426,12295.885,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-12",11,10.93,2406.6,,0.005,0.001,1012.645,0.059,0.095,0.0278,17040.338,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-13",24,24,4937,,0.01,0.001,2064.7,0.059,0.073,0.0042,34741.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-14",24,23.43,4610.51,,0.01,0.001,1957.694,0.059,0.078,0.0052,32937.338,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-15",21,20.08,4018.08,,0.009,0.001,1714.616,0.059,0.086,0.0088,28845.548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-16",19,18.35,2641.66,,0.006,0.001,1216.822,0.059,0.053,0.0063,20474.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-17",24,24,4721,,0.01,0.001,1995.5,0.059,0.069,0.0041,33578.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-18",24,24,5206,,0.011,0.001,2166.4,0.059,0.075,0.0041,36453.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-19",24,24,4693,,0.01,0.001,1992.4,0.059,0.069,0.0042,33525.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-20",24,24,4550,,0.01,0.001,1933.9,0.059,0.066,0.004,32544.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-21",24,24,4567,,0.01,0.001,1947.3,0.059,0.067,0.0041,32764.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-22",24,24,4670,,0.01,0.001,1974.3,0.059,0.068,0.0041,33221.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-23",24,24,4789,,0.01,0.001,2014.7,0.059,0.068,0.004,33899.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-24",24,24,4559,,0.01,0.001,1928.9,0.059,0.067,0.0041,32464.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-25",24,24,4718,,0.01,0.001,2011.8,0.059,0.07,0.0041,33852.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-26",24,24,4632,,0.01,0.001,1988.4,0.059,0.07,0.0042,33462.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-27",24,24,4569,,0.01,0.001,1950.5,0.059,0.068,0.0041,32819.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-28",23,22.18,4138.4,,0.009,0.001,1765.704,0.059,0.063,0.0053,29715.528,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-29",12,11,1478.5,,0.004,0.001,712.07,0.059,0.11,0.0323,11980.605,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-01",9,8.82,1663.48,,0.004,0.001,724.292,0.059,0.076,0.0284,12189.912,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-02",24,24,5464,,0.011,0.001,2253,0.059,0.08,0.0042,37912.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-03",24,24,4653,,0.01,0.001,1987.1,0.059,0.068,0.0041,33436.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-04",18,15.77,3001.45,,0.007,0.001,1308.658,0.059,0.099,0.0213,22016.389,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-05",12,11.88,2646.64,,0.006,0.001,1110.536,0.059,0.09,0.0188,18687.668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-06",24,24,4291,,0.009,0.001,1849.4,0.059,0.065,0.0041,31118.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-07",15,12.99,1888.98,,0.004,0.001,889.294,0.059,0.051,0.0159,14965.941,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-08",18,16.58,2538.88,,0.006,0.001,1162.886,0.059,0.056,0.0112,19567.203,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-09",15,14.2,2023.2,,0.005,0.001,950.06,0.0591,0.074,0.0209,15986.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-10",24,24,5309,,0.011,0.001,2178.5,0.059,0.074,0.004,36656.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-11",24,24,5817,,0.012,0.001,2366,0.059,0.085,0.0043,39814.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-12",24,24,5882,,0.012,0.001,2392.8,0.059,0.085,0.0042,40259.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-13",24,24,5907,,0.012,0.001,2404.2,0.059,0.085,0.0042,40455.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-14",24,24,5801,,0.012,0.001,2367.2,0.059,0.084,0.0042,39829.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-15",24,24,5352,,0.011,0.001,2208.8,0.059,0.079,0.0042,37162.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-16",24,24,5518,,0.011,0.001,2273.9,0.059,0.083,0.0043,38266.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-17",24,24,6046,,0.012,0.001,2464.9,0.059,0.094,0.0045,41476.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-18",24,24,5677,,0.012,0.001,2317.1,0.059,0.083,0.0043,38989.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-19",24,24,5776,,0.012,0.001,2354.5,0.059,0.086,0.0043,39614.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-20",24,24,5928,,0.012,0.001,2415.5,0.059,0.085,0.0042,40645.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-21",24,24,5536,,0.011,0.001,2268.2,0.059,0.08,0.0042,38166.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-22",24,24,5689,,0.012,0.001,2325.7,0.059,0.083,0.0043,39133.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-23",24,24,5697,,0.012,0.001,2323.5,0.059,0.082,0.0042,39102.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-24",24,24,5692,,0.012,0.001,2318.1,0.059,0.085,0.0043,39007.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-25",24,24,5204,,0.011,0.001,2142.6,0.059,0.078,0.0043,36053.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-26",24,24,4738,,0.01,0.001,1990.3,0.059,0.071,0.0043,33492,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-27",24,24,4956,,0.011,0.001,2101.9,0.059,0.073,0.0041,35368.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-28",14,12.7,2554.12,,0.006,0.001,1092.028,0.0591,0.082,0.0234,18377.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-29",24,24,3928,,0.009,0.001,1724.7,0.059,0.063,0.0043,29018.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-09-30",24,23.67,3999.04,,0.009,0.001,1744.242,0.059,0.065,0.0046,29351.449,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-01",14,13.93,2825.37,,0.006,0.001,1191.337,0.059,0.058,0.0065,20047.513,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-02",24,24,4275,,0.009,0.001,1828.1,0.059,0.065,0.0043,30761.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-03",24,24,5650,,0.012,0.001,2303.6,0.059,0.083,0.0043,38762.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-04",24,24,5774,,0.012,0.001,2353.4,0.059,0.087,0.0044,39599.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-05",24,24,6144,,0.013,0.001,2499.5,0.059,0.091,0.0043,42057.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-06",19,18.02,3382,,0.007,0.001,1436.97,0.059,0.059,0.0158,24180.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-07",12,11.65,2676.8,,0.006,0.001,1118.35,0.059,0.091,0.0259,18819.385,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-08",24,24,5117,,0.011,0.001,2123.6,0.059,0.076,0.0043,35732.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-09",24,24,5558,,0.012,0.001,2304.4,0.059,0.089,0.0045,38776.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-10",1,0.95,209,,0,0.001,84.55,0.059,0.009,0.012,1423.005,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-11",14,13.98,2759.96,,0.006,0.001,1214.78,0.0591,0.086,0.0178,20442.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-12",24,24,3734,,0.008,0.001,1660,0.059,0.06,0.0042,27936,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-13",24,23.2,3104.8,,0.007,0.001,1428.96,0.059,0.053,0.0051,24039.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-14",13,12.42,2420.36,,0.005,0.001,1038.548,0.059,0.075,0.0225,17476.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-15",24,24,4705,,0.01,0.001,2024.3,0.059,0.078,0.0045,34059.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-16",23,22.95,3545.7,,0.008,0.001,1598.475,0.059,0.063,0.0047,26898.405,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-17",13,11.28,1805.36,,0.004,0.001,828.328,0.059,0.046,0.0128,13938.748,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-18",13,12.75,2766.5,,0.006,0.001,1187.75,0.059,0.074,0.0146,19985.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-19",24,24,4510,,0.01,0.001,1932.1,0.059,0.076,0.0047,32510.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-20",24,24,4698,,0.01,0.001,1984.9,0.059,0.079,0.0047,33400.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-21",24,24,4759,,0.01,0.001,2016.8,0.059,0.078,0.0046,33937.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-22",24,24,4463,,0.01,0.001,1909.5,0.059,0.078,0.0049,32128.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-23",24,24,5873,,0.012,0.001,2400.8,0.059,0.092,0.0046,40399.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-24",1,0.18,13.68,,0,0.001,7.272,0.059,0.005,0.077,122.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-25",5,4.18,399.9,,0.001,0.001,227.202,0.059,0.148,0.124,3823.104,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-26",24,24,5229,,0.011,0.001,2171.9,0.059,0.077,0.0041,36544.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-27",24,24,5293,,0.011,0.001,2173.2,0.059,0.08,0.0042,36566.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-28",24,24,6269,,0.013,0.001,2519,0.059,0.1,0.0047,42386.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-29",24,24,4708,,0.01,0.001,1980.2,0.059,0.075,0.0045,33322.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-30",24,24,5593,,0.012,0.001,2293.4,0.059,0.091,0.0047,38589.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-10-31",24,24,6481,,0.013,0.001,2613.8,0.059,0.107,0.0049,43980.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-01",24,24,5206,,0.011,0.001,2192.2,0.059,0.091,0.0051,36887.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-02",24,23.18,4326.4,,0.009,0.001,1866.618,0.059,0.08,0.0064,31408.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-03",20,19.57,3926.51,,0.009,0.001,1714.478,0.059,0.08,0.0076,28847.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-04",24,24,4319,,0.01,0.001,1885.2,0.059,0.075,0.0047,31725.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-05",24,24,5700,,0.012,0.001,2405.7,0.059,0.094,0.0046,40479.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-06",11,10.45,2799,,0.006,0.001,1148.42,0.059,0.051,0.0062,19325.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-10",10,9,1714.32,,0.004,0.001,763.26,0.059,0.09,0.0334,12842.226,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-22",2,0.65,0.7,,0,0.001,16.435,0.059,0.022,0.183,276.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-23",5,4.82,101.64,,0.001,0.001,157.238,0.0592,0.234,0.177,2644.338,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-24",19,17.07,3312.66,,0.007,0.001,1480.746,0.059,0.108,0.0192,24914.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-11-30",2,1.92,28.84,,0,0.001,57.996,0.059,0.086,0.179,975.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-01",24,24,3641,,0.009,0.001,1694,0.059,0.183,0.0205,28505.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-02",24,24,4681,,0.01,0.001,2026.9,0.059,0.08,0.0047,34106.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-03",24,24,4222,,0.01,0.001,1912.1,0.059,0.075,0.0047,32175.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-04",1,0.32,30.4,,0,0.001,15.648,0.059,0.003,0.026,263.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-05",10,9.72,1366.44,,0.003,0.001,666.676,0.0591,0.165,0.062,11217.476,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-06",24,23.22,4179.04,,0.01,0.001,1882.584,0.059,0.076,0.0069,31677.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-07",9,8.08,1237.16,,0.003,0.001,591.964,0.059,0.065,0.0244,9962.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-08",24,23.22,3733.48,,0.009,0.001,1690.56,0.059,0.066,0.0058,28444.904,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-09",12,11.8,1873.4,,0.004,0.001,874.28,0.059,0.072,0.0163,14710.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-10",9,8.75,1240.5,,0.003,0.001,576.275,0.059,0.026,0.0054,9697.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-12",19,18.42,3504.84,,0.008,0.001,1586.7,0.0591,0.164,0.0299,26698.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-13",19,17.34,2641.62,,0.006,0.001,1242.816,0.059,0.08,0.0122,20913.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-14",12,11.82,1738.34,,0.004,0.001,830.432,0.059,0.06,0.0128,13974.794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-15",24,24,4768,,0.01,0.001,2062.2,0.059,0.086,0.005,34699.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-16",24,24,5470,,0.012,0.001,2308.4,0.059,0.091,0.0047,38843.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-17",23,22.25,3465.25,,0.008,0.001,1560.825,0.059,0.067,0.0066,26264.075,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-18",12,11.95,2180.9,,0.005,0.001,989.595,0.059,0.078,0.0159,16651.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-19",13,11.2,2100,,0.005,0.001,942.04,0.059,0.074,0.0201,15852.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-20",12,10.88,2007.04,,0.005,0.001,910.218,0.059,0.078,0.0278,15312.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-21",12,11.01,1519.49,,0.004,0.001,732.093,0.059,0.059,0.0145,12317.771,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-23",9,8.92,1404.84,,0.003,0.001,668.712,0.0591,0.171,0.0662,11251.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-24",24,24,3154,,0.008,0.001,1521.4,0.059,0.057,0.0045,25601.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-25",2,1.12,167.32,,0,0.001,76.808,0.059,0.003,0.0045,1292.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-28",17,16.78,2405.56,,0.006,0.001,1174.758,0.059,0.206,0.0406,19771.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-29",24,24,4654,,0.01,0.001,2042.4,0.059,0.082,0.0048,34367,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-30",23,22.18,3824.22,,0.009,0.001,1687.5,0.059,0.064,0.006,28394.966,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-06",13,12.67,1517.04,,0.004,0.001,744.491,0.059,0.046,0.0113,12528.263,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-07",21,20.35,3140.35,,0.007,0.001,1418.505,0.059,0.054,0.005,23870.415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-08",13,12.39,2067.01,,0.005,0.001,929.48,0.059,0.055,0.0115,15639.797,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-16",8,6.95,1086.86,,0.003,0.001,499.939,0.059,0.041,0.0184,8413.426,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-20",15,13.3,2374,,0.005,0.001,1055.26,0.059,0.072,0.0196,17755.89,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-22",20,18.59,4017.79,,0.009,0.001,1708.184,0.059,0.108,0.0165,28740.451,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-23",16,14.37,3168.29,,0.007,0.001,1362.679,0.059,0.081,0.024,22927.478,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-24",18,16.6,3437.04,,0.008,0.001,1513.044,0.059,0.066,0.0121,25462.056,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-25",8,6.3,961.6,,0.002,0.001,453.83,0.059,0.04,0.0343,7637.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-29",8,7.33,1359.56,,0.003,0.001,614.497,0.059,0.063,0.0235,10344.342,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-30",14,12.78,2450.38,,0.006,0.001,1103.088,0.059,0.109,0.0268,18560.938,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-03",11,9.3,1102.82,,0.003,0.001,575.482,0.059,0.071,0.0311,9682.132,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-04",9,8.65,1953.8,,0.004,0.001,845.815,0.059,0.09,0.0328,14232.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-05",24,24,6000,,0.013,0.001,2487,0.059,0.095,0.0046,41847.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-06",24,24,3542,,0.008,0.001,1633.9,0.059,0.06,0.0043,27494.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-07",24,24,3823,,0.009,0.001,1728.6,0.059,0.07,0.0048,29089.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-08",2,1.12,119.32,,0,0.001,60.752,0.059,0.004,0.0325,1021.372,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-12",22,21.35,3782.45,,0.009,0.001,1694.485,0.059,0.1,0.014,28513.395,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-13",24,24,4198,,0.009,0.001,1863.8,0.059,0.079,0.0048,31360,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-14",24,24,5364,,0.012,0.001,2286.8,0.059,0.099,0.0051,38479.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-15",24,24,4824,,0.011,0.001,2135.5,0.059,0.092,0.0051,35932.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-16",24,24,3357,,0.008,0.001,1628,0.059,0.064,0.0046,27393.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-17",24,24,3791,,0.009,0.001,1752.3,0.059,0.074,0.0048,29487.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-18",24,24,4962,,0.011,0.001,2141.7,0.059,0.096,0.0052,36036.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-19",24,24,5865,,0.012,0.001,2460.3,0.059,0.107,0.0052,41401.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-20",24,24,4174,,0.009,0.001,1844.2,0.059,0.079,0.0049,31032.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-21",24,24,4863,,0.011,0.001,2114.3,0.059,0.09,0.0051,35577.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-22",24,23.18,4395.64,,0.01,0.001,1901.002,0.059,0.08,0.0063,31993.222,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-09",22,21.62,4027.82,,0.009,0.001,1753.388,0.059,0.093,0.0083,29504.344,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-10",24,24,6372,,0.013,0.001,2628.6,0.059,0.129,0.0058,44229,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-11",24,24,4871,,0.011,0.001,2086,0.059,0.098,0.0054,35102.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-12",24,24,6160,,0.013,0.001,2546.9,0.059,0.126,0.0058,42857.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-13",24,24,5407,,0.011,0.001,2276.8,0.059,0.109,0.0056,38307.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-14",24,24,5382,,0.011,0.001,2251.3,0.059,0.099,0.0052,37889,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-15",24,24,5136,,0.011,0.001,2145.5,0.059,0.082,0.0046,36102.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-16",24,24,4818,,0.01,0.001,2050.7,0.059,0.092,0.0053,34510,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-17",24,24,4931,,0.011,0.001,2096.6,0.059,0.09,0.0051,35276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-18",24,24,4791,,0.01,0.001,2039.8,0.059,0.083,0.0048,34320.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-19",24,24,5449,,0.011,0.001,2274.3,0.059,0.093,0.0048,38269.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-20",24,24,5120,,0.011,0.001,2148.6,0.059,0.09,0.005,36153.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-21",1,0.1,7.1,,0,0.001,4.07,0.059,0.002,0.066,68.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-23",4,3.98,343.68,,0.001,0.001,207.93,0.059,0.113,0.0948,3497.826,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-24",9,7.78,973.46,,0.003,0.001,497.104,0.059,0.079,0.0324,8363.608,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-25",1,0.13,8.97,,0,0.001,5.265,0.059,0.002,0.051,88.595,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-27",22,21.27,2756.27,,0.007,0.001,1372.874,0.059,0.212,0.032,23099.681,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-28",24,23.38,4665.94,,0.01,0.001,2036.968,0.059,0.11,0.0066,34275.73,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-12",1,0.73,0.73,,0,0.001,19.491,0.059,0.01,0.06,328.573,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-13",10,9.58,682.58,,0.002,0.001,449.744,0.059,0.169,0.0635,7570.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-14",17,15.56,2999.99,,0.007,0.001,1337.476,0.059,0.109,0.0263,22505.754,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-15",14,13.07,2483.95,,0.006,0.001,1105.84,0.059,0.082,0.0168,18605.475,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-16",8,7.37,1626.39,,0.004,0.001,696.442,0.059,0.028,0.0063,11718.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-23",7,6.53,840.53,,0.002,0.001,430.192,0.059,0.037,0.019,7237.444,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-24",24,24,4806,,0.011,0.001,2105.8,0.059,0.086,0.0048,35434.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-25",24,24,4764,,0.01,0.001,2029.9,0.059,0.092,0.0053,34160.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-26",2,1.17,132.24,,0,0.001,63.861,0.059,0.006,0.036,1074.879,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-28",14,13.07,2837.07,,0.006,0.001,1206.612,0.059,0.099,0.0216,20305.666,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-29",24,24,4794,,0.01,0.001,2032.1,0.059,0.083,0.0048,34196.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-04-30",8,7.17,842.11,,0.002,0.001,406.563,0.059,0.023,0.0103,6841.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-01",2,1.27,18.07,,0,0.001,41.886,0.059,0.046,0.128,704.623,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-06",4,2.78,68.02,,0,0.001,91.784,0.0593,0.141,0.1818,1544.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-07",17,15.03,3114.59,,0.007,0.001,1331.918,0.059,0.312,0.0529,22414.149,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-08",23,22.72,3967.28,,0.009,0.001,1723.228,0.059,0.088,0.0061,28994.956,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-28",2,0.54,0.54,,0,0.001,14.184,0.059,0.007,0.043,238.638,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-01",12,11.05,2278.05,,0.005,0.001,961.825,0.059,0.069,0.0222,16182.165,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-02",24,24,4465,,0.01,0.001,1888.3,0.059,0.085,0.0053,31773.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-03",23,22.15,4050.35,,0.009,0.001,1726.835,0.059,0.087,0.0082,29059.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-04",9,8.1,1349.71,,0.003,0.001,599.92,0.059,0.091,0.0386,10093.117,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-09",20,19.37,3862.72,,0.008,0.001,1641.782,0.059,0.134,0.0148,27624.723,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-10",10,9.12,1769.14,,0.004,0.001,763.104,0.059,0.091,0.0293,12841.249,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-11",11,9.8,1998,,0.004,0.001,848.26,0.0591,0.088,0.0266,14275.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-22",11,10.2,1868.8,,0.004,0.001,814.04,0.0591,0.057,0.0195,13700.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-23",23,22.12,3948.24,,0.009,0.001,1700.764,0.059,0.072,0.0065,28618.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-24",5,3.39,286.59,,0.001,0.001,169.049,0.059,0.048,0.0792,2844.863,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-25",24,24,4555,,0.01,0.001,1931.6,0.059,0.083,0.005,32507.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-26",7,6.37,1101.29,,0.002,0.001,484.732,0.059,0.067,0.0366,8156.542,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-27",24,24,4914,,0.01,0.001,2043,0.059,0.087,0.005,34376.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-28",7,6.18,1352.2,,0.003,0.001,560.242,0.059,0.024,0.0053,9426.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-06",10,8.68,1266.7,,0.003,0.001,601.584,0.059,0.043,0.0196,10122.251,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-07",21,20.14,3697.92,,0.008,0.001,1615.65,0.059,0.081,0.007,27187.576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-08",18,16.77,3659.87,,0.008,0.001,1510.779,0.059,0.081,0.0101,25419.704,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-09",11,10.73,2164.95,,0.005,0.001,921.537,0.059,0.082,0.0272,15507.452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-10",24,24,4794,,0.01,0.001,2004.4,0.059,0.069,0.0041,33723.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-11",24,24,5125,,0.011,0.001,2112.6,0.059,0.072,0.0041,35548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-12",24,24,4762,,0.01,0.001,1992.3,0.059,0.068,0.0041,33523.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-13",24,24,4628,,0.01,0.001,1952.4,0.059,0.067,0.0041,32851.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-14",24,24,4153,,0.009,0.001,1775.5,0.059,0.064,0.0043,29872.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-15",24,24,4737,,0.01,0.001,1970.9,0.059,0.064,0.0039,33164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-16",24,24,4501,,0.01,0.001,1906.6,0.059,0.064,0.004,32084,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-17",24,24,4729,,0.01,0.001,2024.1,0.059,0.068,0.004,34058.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-18",24,24,4648,,0.01,0.001,1943.6,0.059,0.064,0.0039,32704.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-19",24,24,4097,,0.009,0.001,1756.7,0.059,0.058,0.0039,29560.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-20",24,24,3947,,0.009,0.001,1715.7,0.059,0.059,0.0041,28871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-21",24,23.9,4439.4,,0.01,0.001,1881.97,0.059,0.067,0.0042,31668.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-27",11,10.57,2136.27,,0.005,0.001,906.877,0.059,0.064,0.0178,15259.415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-28",24,23.88,4067.84,,0.009,0.001,1754.376,0.059,0.054,0.0038,29522.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-29",15,14.9,2946.5,,0.006,0.001,1253.79,0.059,0.18,0.037,21097.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-30",24,24,4362,,0.009,0.001,1866.7,0.059,0.055,0.0036,31409.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-07-31",24,24,4790,,0.01,0.001,2003.5,0.059,0.057,0.0034,33713.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-01",24,24,4070,,0.009,0.001,1752.8,0.059,0.052,0.0035,29497.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-02",24,24,4076,,0.009,0.001,1759.3,0.059,0.06,0.0041,29603,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-03",24,24,4103,,0.009,0.001,1792.6,0.059,0.06,0.004,30165.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-04",24,24,3947,,0.009,0.001,1721.3,0.059,0.059,0.0041,28965.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-05",7,6.18,749.2,,0.002,0.001,356.692,0.059,0.012,0.0039,6003.324,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-09",7,5.88,1187.39,,0.003,0.001,512.873,0.059,0.063,0.0343,8629.245,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-10",14,12.7,2174.32,,0.005,0.001,983.876,0.059,0.08,0.0246,16554.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-11",7,5.89,1117.25,,0.002,0.001,486.557,0.059,0.06,0.0391,8186.438,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-12",14,13.72,2925.16,,0.006,0.001,1250.268,0.059,0.089,0.0228,21034.884,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-13",24,24,5003,,0.011,0.001,2084.2,0.059,0.07,0.004,35068.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-14",24,23.42,4658.2,,0.01,0.001,1968.202,0.059,0.071,0.0048,33115.052,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-15",18,17.37,3614.43,,0.008,0.001,1516.552,0.059,0.068,0.0112,25518.131,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-16",14,13.58,2062.06,,0.005,0.001,921.671,0.059,0.043,0.0062,15506.795,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-17",24,24,4781,,0.01,0.001,2009.6,0.059,0.068,0.004,33815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-18",24,24,5232,,0.011,0.001,2172,0.059,0.074,0.0041,36548.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-19",24,24,4700,,0.01,0.001,1989.3,0.059,0.067,0.004,33474.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-20",24,24,4609,,0.01,0.001,1949.3,0.059,0.066,0.004,32800.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-21",24,24,4618,,0.01,0.001,1954.1,0.059,0.066,0.004,32877.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-22",24,24,4712,,0.01,0.001,1984.2,0.059,0.067,0.004,33389.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-23",24,24,4802,,0.01,0.001,2016.1,0.059,0.068,0.004,33928.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-24",24,24,4588,,0.01,0.001,1925.8,0.059,0.066,0.0041,32404,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-25",22,20,3817.25,,0.008,0.001,1626.005,0.059,0.072,0.009,27356.655,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-26",21,20.22,3956.64,,0.008,0.001,1682.606,0.059,0.073,0.013,28310.646,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-27",24,24,4598,,0.01,0.001,1946.8,0.059,0.066,0.004,32759.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-28",23,22.17,4196.13,,0.009,0.001,1782.575,0.059,0.063,0.0051,29993.249,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-29",5,4.25,400.03,,0.001,0.001,220.081,0.059,0.053,0.0544,3702.199,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-08-31",9,8.55,862.55,,0.002,0.001,467.1,0.059,0.142,0.0616,7861.755,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-01",17,15.85,2858.84,,0.006,0.001,1282.77,0.059,0.067,0.0103,21581.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-02",24,24,5470,,0.011,0.001,2251.7,0.059,0.077,0.0041,37887.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-03",24,23.63,4590.22,,0.01,0.001,1959.565,0.059,0.069,0.0043,32974.161,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-04",11,10.52,2306.21,,0.005,0.001,975.869,0.059,0.06,0.0108,16421.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-05",19,18.57,3793.96,,0.008,0.001,1632.302,0.059,0.089,0.0136,27468.501,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-06",24,24,4367,,0.009,0.001,1871.2,0.059,0.065,0.0041,31488.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-07",8,6.41,704.74,,0.002,0.001,354.938,0.059,0.056,0.0301,5972.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-08",12,10.73,1563.39,,0.004,0.001,716.527,0.059,0.057,0.0215,12059.365,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-09",10,9.97,1391.98,,0.003,0.001,639.113,0.059,0.07,0.022,10754.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-10",24,24,5328,,0.011,0.001,2187.2,0.059,0.057,0.003,36805.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-11",24,24,5808,,0.012,0.001,2360.4,0.059,0.074,0.0037,39719.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-12",24,24,5880,,0.012,0.001,2392,0.059,0.082,0.004,40254.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-13",24,24,5902,,0.012,0.001,2401.1,0.059,0.087,0.0043,40404.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-14",24,24,5796,,0.012,0.001,2365.6,0.059,0.089,0.0045,39809.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-15",24,24,5430,,0.011,0.001,2235.9,0.059,0.077,0.0041,37624.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-16",24,24,5526,,0.011,0.001,2278.1,0.059,0.081,0.0043,38329.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-17",24,24,6035,,0.012,0.001,2462.2,0.059,0.083,0.004,41424.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-18",24,24,5660,,0.012,0.001,2310.3,0.059,0.081,0.0042,38872.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-19",24,24,5768,,0.012,0.001,2352,0.059,0.079,0.004,39574.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-20",24,24,5891,,0.012,0.001,2384.1,0.059,0.082,0.0041,40120.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-21",24,24,5536,,0.011,0.001,2268.1,0.059,0.076,0.004,38168.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-22",24,24,5683,,0.012,0.001,2322.4,0.059,0.08,0.0041,39080.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-23",24,24,5690,,0.012,0.001,2318.7,0.059,0.078,0.004,39014.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-24",24,24,5692,,0.012,0.001,2317.8,0.059,0.078,0.004,39001.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-25",24,24,5204,,0.011,0.001,2141.3,0.059,0.072,0.004,36036.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-26",24,24,4755,,0.01,0.001,1993.8,0.059,0.067,0.004,33551.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-27",17,15.78,3253.91,,0.007,0.001,1378.315,0.059,0.064,0.0108,23194.814,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-28",15,14.55,2792.85,,0.006,0.001,1227.2,0.059,0.079,0.0116,20650.339,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-29",24,24,4015,,0.009,0.001,1747.4,0.059,0.06,0.0041,29403.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-09-30",24,23.65,4039.75,,0.009,0.001,1756.355,0.059,0.061,0.0043,29552.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-01",18,17.53,3350.32,,0.007,0.001,1441.398,0.059,0.063,0.0074,24253.667,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-02",24,24,4355,,0.009,0.001,1852.4,0.059,0.063,0.0041,31172.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-03",24,24,5667,,0.012,0.001,2313,0.059,0.078,0.004,38919.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-04",24,24,5783,,0.012,0.001,2353.4,0.059,0.079,0.004,39598.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-05",24,24,6137,,0.013,0.001,2490.5,0.059,0.084,0.004,41909.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-06",23,22.2,4387.4,,0.009,0.001,1850.68,0.059,0.067,0.0053,31139.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-07",18,17.52,3886.8,,0.008,0.001,1643.052,0.059,0.08,0.0108,27648.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-08",24,24,5123,,0.011,0.001,2123.3,0.059,0.073,0.0041,35728.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-09",24,24,5621,,0.012,0.001,2317.9,0.059,0.08,0.0041,39003.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-10",1,0.93,211.11,,0,0.001,85.281,0.059,0.009,0.013,1435.548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-11",10,9.85,2058.6,,0.004,0.001,880.11,0.059,0.074,0.0231,14808.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-12",24,24,3813,,0.008,0.001,1683.1,0.059,0.058,0.0041,28319.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-13",23,22.4,3055,,0.007,0.001,1399.58,0.059,0.048,0.0045,23551.98,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-14",17,16.78,3131.46,,0.007,0.001,1370.826,0.059,0.072,0.0088,23066.212,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-15",15,13.53,2946.84,,0.006,0.001,1242.53,0.059,0.09,0.0157,20909.581,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-16",13,12.66,2245.54,,0.005,0.001,966.329,0.059,0.075,0.0183,16260.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-17",9,7.4,1232.94,,0.003,0.001,542.999,0.059,0.064,0.0352,9135.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-18",10,9.72,2126.08,,0.005,0.001,897.936,0.0591,0.094,0.0309,15109.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-19",24,24,4595,,0.01,0.001,1957.4,0.059,0.091,0.0054,32934.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-20",24,24,4804,,0.01,0.001,2018.3,0.059,0.088,0.0052,33960.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-21",24,24,4873,,0.01,0.001,2050.5,0.059,0.095,0.0055,34503.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-22",24,24,4552,,0.01,0.001,1944.2,0.059,0.088,0.0053,32714.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-23",24,24,5917,,0.012,0.001,2406.5,0.059,0.116,0.0057,40490.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-24",1,0.18,13.5,,0,0.001,7.236,0.059,0.005,0.086,121.77,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-26",23,22.77,4666.1,,0.01,0.001,1957.471,0.059,0.141,0.0163,32938.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-27",24,24,5301,,0.011,0.001,2183.6,0.059,0.076,0.0042,36744.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-28",24,24,6287,,0.013,0.001,2534,0.059,0.109,0.0051,42641.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-29",24,24,4772,,0.01,0.001,2001.4,0.059,0.079,0.0047,33673.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-30",24,24,5635,,0.012,0.001,2303.3,0.059,0.102,0.0053,38759.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-10-31",24,24,6459,,0.013,0.001,2598.4,0.059,0.126,0.0058,43723,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-01",24,24,5208,,0.011,0.001,2187.8,0.059,0.094,0.005,36814.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-02",24,23.17,4321.28,,0.009,0.001,1860.744,0.059,0.081,0.0068,31311.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-03",12,11.78,2101.82,,0.005,0.001,929.208,0.059,0.088,0.0242,15633.846,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-04",24,24,4366,,0.01,0.001,1897.2,0.059,0.085,0.0053,31920.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-05",14,12.38,2782.48,,0.006,0.001,1178.796,0.0591,0.101,0.0367,19838.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-06",11,10.43,2792.06,,0.006,0.001,1142.688,0.059,0.059,0.007,19229.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-10",10,8.92,742.5,,0.002,0.001,456.61,0.059,0.17,0.0616,7682.792,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-23",2,0.55,0.67,,0,0.001,14.646,0.059,0.013,0.1,246.703,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-24",16,13.44,2695.93,,0.006,0.001,1183.862,0.0591,0.151,0.0421,19919.378,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-01",18,17.53,2933.3,,0.007,0.001,1308.416,0.059,0.083,0.0123,22014.799,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-02",24,24,4677,,0.01,0.001,2022.9,0.059,0.075,0.0044,34037.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-03",11,10.42,1972.7,,0.004,0.001,875.482,0.0591,0.094,0.0313,14731.076,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-04",1,0.32,31.04,,0,0.001,15.872,0.059,0.004,0.027,266.848,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-06",10,8.97,1703.38,,0.004,0.001,756.276,0.059,0.07,0.0256,12725.707,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-08",20,18.75,3015.7,,0.007,0.001,1356.725,0.059,0.104,0.0176,22827.195,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-09",9,8.72,1484.04,,0.003,0.001,666.212,0.059,0.062,0.0227,11208.668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-10",9,8.73,1298.62,,0.003,0.001,596.144,0.059,0.024,0.0049,10031.763,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-12",9,8.73,1866.49,,0.004,0.001,815.083,0.059,0.068,0.0196,13717.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-13",13,10.51,1305.5,,0.003,0.001,634.596,0.0591,0.061,0.0236,10676.907,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-14",9,8.62,1283.92,,0.003,0.001,599.194,0.059,0.056,0.0284,10083.132,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-15",24,24,4834,,0.01,0.001,2076.8,0.059,0.077,0.0044,34942.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-16",24,24,5567,,0.012,0.001,2339.6,0.059,0.088,0.0045,39367.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-17",23,22.23,3550.24,,0.008,0.001,1588.687,0.059,0.063,0.0063,26728.847,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-18",9,8.88,1788.96,,0.004,0.001,780.368,0.059,0.063,0.018,13132.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-19",10,8.43,1630.8,,0.004,0.001,714.054,0.059,0.071,0.0244,12014.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-20",9,7.89,1421,,0.003,0.001,636.809,0.059,0.074,0.0373,10714.43,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-21",8,7.88,1021.28,,0.002,0.001,489.214,0.059,0.059,0.0189,8231.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-24",21,20.25,2507.25,,0.006,0.001,1219.75,0.059,0.078,0.0144,20523.175,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-25",1,0.65,59.15,,0,0.001,35.75,0.059,0.004,0.012,601.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-28",6,4.92,682.2,,0.002,0.001,326.422,0.059,0.036,0.0302,5492.17,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-29",16,15.47,3312.23,,0.007,0.001,1420.99,0.059,0.089,0.0174,23913.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-30",23,22.17,3842.45,,0.009,0.001,1687.295,0.059,0.065,0.0063,28391.338,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"3-2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-06",23,22.68,2561.68,,0.007,0.001,1302.2,0.059,0.222,0.0362,21911.132,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-07",9,8.52,955.28,,0.002,0.001,476.572,0.059,0.018,0.0044,8019.936,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-08",7,6.01,755.82,,0.002,0.001,367.626,0.059,0.071,0.0509,6186.53,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-09",18,17.76,3480.55,,0.008,0.001,1532.863,0.059,0.073,0.0064,25793.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-10",17,15.96,2357.12,,0.006,0.001,1106.28,0.059,0.055,0.0087,18613.632,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-11",18,16.5,1752.98,,0.005,0.001,911.852,0.059,0.064,0.0184,15343.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-17",21,19.98,3215.94,,0.007,0.001,1437.559,0.059,0.113,0.0203,24192.661,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-18",12,10.66,2112.08,,0.005,0.001,931.33,0.059,0.048,0.0127,15670.262,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-19",19,17.81,3133.05,,0.007,0.001,1396.172,0.059,0.091,0.0179,23491.827,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-20",21,20.72,3990.88,,0.009,0.001,1736.628,0.059,0.081,0.0065,29223.964,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-21",23,21.14,2367.91,,0.006,0.001,1188.983,0.059,0.056,0.0072,20009.209,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-23",2,0.35,4.55,,0,0.001,10.773,0.059,0.023,0.2195,181.489,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-24",23,22.08,5091.28,,0.011,0.001,2134.66,0.059,0.174,0.0208,35920.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-25",18,17.63,3176.87,,0.007,0.001,1423.948,0.059,0.069,0.0079,23962.009,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-26",21,20.08,3147.12,,0.007,0.001,1430.556,0.059,0.055,0.0071,24072.668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-27",21,20.77,2880.11,,0.007,0.001,1362.597,0.059,0.074,0.0083,22929.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-28",24,24,4198,,0.009,0.001,1835,0.059,0.065,0.0043,30877.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-29",24,24,5210,,0.011,0.001,2205.5,0.059,0.081,0.0044,37110.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-30",24,24,4791,,0.01,0.001,2054.2,0.059,0.073,0.0042,34566.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-01-31",24,24,4603,,0.01,0.001,1996.9,0.059,0.072,0.0043,33599.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-01",24,24,3948,,0.009,0.001,1748.8,0.059,0.063,0.0043,29427.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-02",17,14.97,2573.73,,0.006,0.001,1172.552,0.059,0.067,0.0151,19729.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-03",22,21.5,3677.5,,0.008,0.001,1651.5,0.059,0.08,0.0094,27787.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-04",24,24,5682,,0.012,0.001,2362.4,0.059,0.084,0.0043,39750.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-05",24,24,6063,,0.013,0.001,2494,0.059,0.086,0.0041,41964.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-06",24,24,3657,,0.008,0.001,1655,0.059,0.059,0.0043,27847.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-07",24,24,3857,,0.009,0.001,1730.5,0.059,0.062,0.0042,29123.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-08",21,19.08,2836.05,,0.007,0.001,1322.52,0.059,0.068,0.0206,22256.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-09",17,16.2,2269.76,,0.005,0.001,1084.312,0.059,0.071,0.0178,18244.932,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-10",18,16.67,2620.74,,0.006,0.001,1219.605,0.059,0.051,0.0087,20522.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-11",23,22.35,3751.45,,0.009,0.001,1695.6,0.059,0.072,0.0107,28527.115,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-12",23,21.17,3273.22,,0.008,0.001,1497.577,0.059,0.062,0.0108,25201.904,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-13",24,24,4253,,0.009,0.001,1880.3,0.059,0.067,0.0042,31640.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-14",24,23.88,5424.84,,0.011,0.001,2267.032,0.059,0.088,0.0048,38145.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-15",16,15.45,2664.97,,0.006,0.001,1211.718,0.059,0.086,0.0192,20389.422,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-16",1,0.22,0.22,,0,0.001,5.654,0.059,0.009,0.198,95.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-17",24,24,3453,,0.008,0.001,1623.7,0.059,0.169,0.0224,27320.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-18",24,24,4945,,0.011,0.001,2113.3,0.059,0.074,0.0041,35561.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-19",24,24,5958,,0.012,0.001,2469.7,0.059,0.087,0.0042,41559.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-20",24,24,4150,,0.009,0.001,1821.6,0.059,0.063,0.0041,30650.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-21",24,24,4858,,0.01,0.001,2071.1,0.059,0.07,0.004,34846.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-22",24,24,4712,,0.01,0.001,2001.6,0.059,0.069,0.0041,33685,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-23",1,0.05,4.3,,0,0.001,2.565,0.059,0,0.004,43.135,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-04",17,16.32,2649.32,,0.006,0.001,1238.628,0.0591,0.224,0.0528,20840.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-05",24,24,5494,,0.011,0.001,2269.2,0.059,0.082,0.0043,38185.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-06",24,24,5809,,0.012,0.001,2383.5,0.059,0.083,0.0041,40106.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-07",24,24,5615,,0.012,0.001,2311.2,0.059,0.079,0.004,38892.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-08",24,24,5835,,0.012,0.001,2395.7,0.059,0.081,0.004,40307.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-09",24,24,4700,,0.01,0.001,2038.3,0.059,0.069,0.004,34296.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-10",2,1.12,114.04,,0,0.001,59.076,0.059,0.004,0.0255,994.148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-15",2,1.62,17.62,,0,0.001,44.586,0.0595,0.07,0.191,750.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-16",24,24,4058,,0.009,0.001,1843.6,0.059,0.172,0.0201,31028.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-17",24,24,4935,,0.011,0.001,2132.2,0.059,0.073,0.0041,35876.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-18",24,24,4463,,0.01,0.001,1900.8,0.059,0.065,0.004,31986.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-19",24,24,4884,,0.01,0.001,2054,0.059,0.069,0.004,34562.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-20",24,24,4559,,0.01,0.001,1938.1,0.059,0.066,0.004,32610,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-21",24,24,5380,,0.011,0.001,2222.3,0.059,0.076,0.0041,37392.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-22",24,24,4997,,0.011,0.001,2107.3,0.059,0.071,0.004,35462.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-23",24,24,4440,,0.01,0.001,1896.1,0.059,0.065,0.0041,31906,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-24",24,24,4816,,0.01,0.001,2079.7,0.059,0.073,0.0042,34994,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-25",24,24,4814,,0.01,0.001,2068.5,0.059,0.071,0.0041,34810.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-26",23,22.6,3954.2,,0.009,0.001,1747.12,0.059,0.061,0.0043,29396.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-03-31",7,6.75,593.25,,0.002,0.001,339.9,0.059,0.154,0.0859,5717.975,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-01",8,7.37,1248.77,,0.003,0.001,560.875,0.059,0.022,0.0056,9437.934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-05",7,6.52,458.52,,0.002,0.001,300.756,0.059,0.187,0.1146,5061.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-06",24,24,5109,,0.011,0.001,2206.8,0.059,0.077,0.0042,37135,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-07",24,24,5213,,0.011,0.001,2200.3,0.059,0.082,0.0045,37023.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-08",24,24,5747,,0.012,0.001,2357.8,0.059,0.082,0.0041,39675.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-09",24,24,6340,,0.013,0.001,2592.4,0.059,0.088,0.004,43622.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-10",24,24,4048,,0.009,0.001,1774.3,0.059,0.065,0.0044,29856.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-11",2,1.13,120.49,,0,0.001,59.412,0.059,0.003,0.017,1000.155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-25",1,0.42,0.42,,0,0.001,11.34,0.06,0.016,0.168,190.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-26",2,0.55,0.55,,0,0.001,14.546,0.0595,0.023,0.191,244.449,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-01",2,1.42,24.14,,0,0.001,46.396,0.0595,0.074,0.191,779.772,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-06",9,7.9,585.52,,0.002,0.001,389.44,0.0591,0.231,0.0897,6552.891,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-07",24,21.26,3479.83,,0.008,0.001,1579.593,0.0591,0.079,0.0073,26577.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-08",24,23.72,4258.48,,0.009,0.001,1834.372,0.059,0.072,0.0049,30864.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-27",11,8.51,1176.54,,0.003,0.001,566.162,0.0591,0.074,0.0435,9528.052,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-28",12,11.41,2420.07,,0.005,0.001,1043.055,0.059,0.059,0.0087,17551.979,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-01",7,6.57,833.83,,0.002,0.001,433.152,0.0591,0.176,0.0934,7286.464,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-02",24,23.08,4512.93,,0.01,0.001,1959.012,0.059,0.077,0.0049,32964.821,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-03",23,22.05,4045.15,,0.009,0.001,1733.57,0.059,0.061,0.0042,29171.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-04",13,11.58,1871.71,,0.004,0.001,864.621,0.0591,0.055,0.0093,14545.291,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-05",8,6.95,667.6,,0.002,0.001,367.665,0.059,0.051,0.0246,6187.785,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-09",17,16.42,2662.42,,0.006,0.001,1246.672,0.0591,0.287,0.0591,20977.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-10",24,24,5267,,0.011,0.001,2193.6,0.059,0.076,0.0041,36911.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-11",23,22.05,3290.85,,0.007,0.001,1483.56,0.059,0.064,0.0062,24963.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-12",2,1.37,241.77,,0.001,0.001,103.516,0.059,0.006,0.0105,1741.072,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-22",5,3.77,75.14,,0.001,0.001,120.997,0.059,0.138,0.1398,2038.071,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-23",24,23.7,4156.1,,0.009,0.001,1809.61,0.059,0.112,0.013,30450.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-24",24,24,4929,,0.01,0.001,2067.1,0.059,0.081,0.0046,34781.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-25",1,0.12,4.8,,0,0.001,5.064,0.059,0.001,0.034,85.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-29",6,4.93,377.68,,0.001,0.001,239.5,0.059,0.139,0.1003,4029.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-06",17,15.8,2015.12,,0.005,0.001,993.372,0.059,0.241,0.0551,16713.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-07",15,14.03,2693.03,,0.006,0.001,1179.398,0.0591,0.067,0.009,19844.355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-08",24,24,4807,,0.01,0.001,2001.6,0.059,0.074,0.0044,33680.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-09",24,24,4775,,0.01,0.001,2014.1,0.059,0.078,0.0046,33891.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-10",24,24,5517,,0.011,0.001,2257.1,0.059,0.088,0.0046,37980.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-11",24,24,5129,,0.011,0.001,2123.5,0.059,0.081,0.0045,35733.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-12",24,24,4885,,0.01,0.001,2040.2,0.059,0.077,0.0044,34329,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-13",23,22.87,4323.83,,0.009,0.001,1833.559,0.059,0.073,0.0047,30853.849,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-14",14,13.63,2253.12,,0.005,0.001,1015.425,0.059,0.069,0.0157,17084.819,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-15",24,24,4701,,0.01,0.001,1967.4,0.059,0.071,0.0043,33102.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-16",24,24,4601,,0.01,0.001,1934.9,0.059,0.071,0.0044,32559.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-17",24,24,4788,,0.01,0.001,1997.6,0.059,0.073,0.0043,33610.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-18",24,24,4812,,0.01,0.001,2005.6,0.059,0.062,0.0036,33747.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-19",24,24,4863,,0.01,0.001,2016.2,0.059,0.072,0.0042,33926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-20",24,24,4139,,0.009,0.001,1780.1,0.059,0.067,0.0046,29955.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-21",24,24,4445,,0.01,0.001,1888.8,0.059,0.07,0.0045,31780.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-22",19,17.81,4091.05,,0.009,0.001,1717.259,0.059,0.071,0.0079,28895.677,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-25",10,9.28,1593.28,,0.004,0.001,744.96,0.0591,0.169,0.0674,12534.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-26",24,24,5199,,0.011,0.001,2202.4,0.059,0.078,0.0042,37061.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-27",24,24,4894,,0.01,0.001,2043.2,0.059,0.074,0.0044,34381.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-28",24,24,5002,,0.01,0.001,2059.2,0.059,0.07,0.004,34652.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-29",24,24,4969,,0.01,0.001,2055.3,0.059,0.07,0.004,34587,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-30",24,24,4963,,0.01,0.001,2054.6,0.059,0.071,0.0041,34574.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-07-31",24,24,5238,,0.011,0.001,2158.2,0.059,0.074,0.0041,36315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-01",24,23.17,4503.53,,0.009,0.001,1879.521,0.059,0.068,0.0055,31624.459,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-02",14,13.83,2815.28,,0.006,0.001,1218.471,0.059,0.085,0.0169,20504.995,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-03",24,23.7,4782.4,,0.01,0.001,1996.21,0.059,0.071,0.0044,33594.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-04",9,7.92,1623.36,,0.004,0.001,698.187,0.059,0.047,0.0171,11747.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-09",11,10.97,2401.52,,0.005,0.001,1017.866,0.059,0.087,0.0225,17127.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-10",24,24,4243,,0.009,0.001,1848.1,0.059,0.063,0.0041,31100.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-11",22,21.17,3213.11,,0.007,0.001,1433.384,0.059,0.054,0.0053,24121.417,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-12",21,20.57,3986.41,,0.009,0.001,1734.228,0.059,0.116,0.0173,29179.526,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-13",24,24,4867,,0.01,0.001,2046.1,0.059,0.069,0.004,34429.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-14",24,23.48,4582.4,,0.01,0.001,1943.712,0.059,0.073,0.0053,32702.376,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-15",14,13.43,2920.23,,0.006,0.001,1225.613,0.059,0.05,0.0074,20623.895,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-16",24,24,3718,,0.008,0.001,1678.9,0.059,0.058,0.0041,28249,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-17",24,24,4570,,0.01,0.001,1951.9,0.059,0.066,0.004,32842.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-18",24,24,5298,,0.011,0.001,2208.9,0.059,0.075,0.004,37169,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-19",24,24,4519,,0.01,0.001,1939.2,0.059,0.07,0.0045,32632.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-20",24,24,4662,,0.01,0.001,1978.8,0.059,0.067,0.004,33299.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-21",24,24,4642,,0.01,0.001,1967.4,0.059,0.066,0.004,33108.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-22",24,24,4847,,0.01,0.001,2042,0.059,0.072,0.0042,34360.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-23",24,24,4763,,0.01,0.001,2007.6,0.059,0.08,0.0048,33784.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-24",24,24,4775,,0.01,0.001,2017.6,0.059,0.082,0.0048,33951.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-25",24,24,4654,,0.01,0.001,1976.1,0.059,0.08,0.0048,33253.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-26",24,24,4450,,0.01,0.001,1904.9,0.059,0.077,0.0048,32054,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-27",24,24,4640,,0.01,0.001,1995.9,0.059,0.078,0.0046,33585.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-28",24,24,4611,,0.01,0.001,1976.1,0.059,0.077,0.0046,33249.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-29",10,8.87,1318.61,,0.003,0.001,596.821,0.059,0.062,0.0264,10043.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-30",9,8.02,987.88,,0.002,0.001,474.334,0.059,0.054,0.022,7980.933,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-08-31",24,23.17,2693.94,,0.007,0.001,1300.618,0.059,0.056,0.0059,21885.497,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-02",15,14.8,2425.8,,0.006,0.001,1119.24,0.059,0.188,0.0421,18834.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-03",24,24,5364,,0.011,0.001,2211,0.059,0.085,0.0045,37204.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-04",24,23.4,4512.4,,0.01,0.001,1925.16,0.059,0.078,0.0052,32391.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-05",18,17.05,3739.6,,0.008,0.001,1576.215,0.059,0.082,0.0134,26522.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-06",1,0.5,16,,0,0.001,17.6,0.059,0.032,0.219,296.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-04",2,0.57,0.57,,0,0.001,14.952,0.059,0.021,0.163,251.694,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-05",12,9.68,792.08,,0.003,0.001,501.906,0.0592,0.279,0.1046,8443.382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-06",13,12.23,2440.99,,0.005,0.001,1071.018,0.059,0.135,0.0389,18022.887,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-07",13,11.8,2190.4,,0.005,0.001,974.292,0.059,0.066,0.0158,16394.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-08",13,12.03,2459,,0.005,0.001,1045.689,0.059,0.075,0.0137,17595.129,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-09",24,24,5874,,0.012,0.001,2415.3,0.059,0.075,0.0037,40640.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-10",24,24,5089,,0.011,0.001,2124.8,0.059,0.059,0.0033,35754.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-11",24,24,5398,,0.011,0.001,2234.3,0.059,0.083,0.0044,37593.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-12",24,24,3833,,0.009,0.001,1701.2,0.059,0.064,0.0045,28627.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-13",24,23.15,3072.1,,0.007,0.001,1417.84,0.059,0.059,0.0063,23859.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-14",17,16.47,2884.97,,0.007,0.001,1292.429,0.059,0.055,0.007,21746.081,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-15",24,24,4567,,0.01,0.001,1987.7,0.059,0.073,0.0044,33445.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-16",24,24,3652,,0.008,0.001,1661.4,0.059,0.066,0.0048,27957.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-17",23,22.17,3561.11,,0.008,0.001,1605.618,0.059,0.06,0.0054,27016.514,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-18",13,12.78,2785,,0.006,0.001,1205.09,0.059,0.068,0.0101,20279.156,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-19",19,18.28,3675.28,,0.008,0.001,1575.02,0.0591,0.09,0.0172,26501.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-20",24,24,4748,,0.01,0.001,2013.4,0.059,0.081,0.0048,33877.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-21",24,24,5255,,0.011,0.001,2183.4,0.059,0.087,0.0048,36742.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-22",24,24,4364,,0.01,0.001,1884.6,0.059,0.076,0.0048,31714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-23",24,24,5807,,0.012,0.001,2380.4,0.059,0.098,0.0049,40052.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-24",24,24,5907,,0.012,0.001,2415.5,0.059,0.098,0.0048,40646.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-25",24,24,6058,,0.012,0.001,2466.2,0.059,0.098,0.0048,41501.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-26",24,24,5303,,0.011,0.001,2213.8,0.059,0.08,0.0043,37246.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-27",24,24,5239,,0.011,0.001,2178.8,0.059,0.077,0.0042,36665.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-28",24,24,5555,,0.012,0.001,2286,0.059,0.079,0.0041,38470.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-29",24,24,5049,,0.011,0.001,2107.5,0.059,0.057,0.0033,35464.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-30",24,24,5544,,0.012,0.001,2283.1,0.059,0.067,0.0035,38414.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-10-31",24,24,6314,,0.013,0.001,2563.3,0.059,0.084,0.0039,43132.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-01",24,24,5761,,0.012,0.001,2405.3,0.059,0.071,0.0035,40473.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-02",24,24,4360,,0.01,0.001,1902.2,0.059,0.075,0.0047,32006.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-03",24,24,4771,,0.01,0.001,2051.2,0.059,0.081,0.0047,34513.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-04",24,24,4259,,0.009,0.001,1874.3,0.059,0.073,0.0045,31532.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-05",24,24,5688,,0.012,0.001,2398.2,0.059,0.1,0.005,40352.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-06",24,24,6304,,0.013,0.001,2608.5,0.059,0.11,0.005,43890.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-07",2,1.17,211.45,,0,0.001,92.397,0.059,0.007,0.0285,1554.442,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-09",23,23,4469,,0.01,0.001,1977.4,0.059,0.198,0.024,33268,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-10",24,24,4769,,0.01,0.001,2056.8,0.059,0.087,0.005,34608.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-11",24,24,4491,,0.01,0.001,1970.7,0.059,0.084,0.0051,33160.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-12",24,24,4698,,0.01,0.001,2004.3,0.059,0.084,0.005,33728.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-13",2,1.42,220.14,,0.001,0.001,103.37,0.059,0.006,0.0075,1740.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-16",7,6.95,478.95,,0.002,0.001,331.465,0.059,0.225,0.12,5577.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-17",23,22.2,3337.8,,0.008,0.001,1567.34,0.059,0.066,0.0066,26366.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-18",20,19.33,2806.57,,0.007,0.001,1322.603,0.059,0.076,0.0134,22257.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-19",24,23.2,4006.8,,0.009,0.001,1828.38,0.059,0.084,0.0076,30764.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-20",10,9.43,1838.67,,0.004,0.001,807.719,0.059,0.049,0.0116,13592.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-21",13,11.21,2254.07,,0.005,0.001,980.544,0.059,0.058,0.0119,16499.862,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-24",12,11.1,1569.21,,0.004,0.001,776.573,0.059,0.191,0.0538,13067.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-08",12,10.26,1866.44,,0.004,0.001,837.81,0.059,0.11,0.04,14098.588,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-09",15,13.4,2402.4,,0.005,0.001,1070.36,0.059,0.093,0.0272,18013.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-10",1,0.37,24.79,,0,0.001,18.722,0.059,0.003,0.02,314.981,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-13",16,14.48,1607.28,,0.004,0.001,849.44,0.059,0.248,0.0633,14296.352,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-14",9,7.72,1239.24,,0.003,0.001,569.352,0.059,0.052,0.0276,9579.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-15",9,8.47,1844.33,,0.004,0.001,799.028,0.059,0.075,0.0332,13443.831,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-17",23,21.25,3492.11,,0.008,0.001,1590.368,0.059,0.119,0.0192,26761.917,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-21",15,13.45,1495.37,,0.004,0.001,789.127,0.059,0.227,0.0628,13278.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-22",11,10.67,1251.67,,0.003,0.001,645.121,0.059,0.071,0.0281,10857.575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-23",17,15.92,2586.6,,0.006,0.001,1203.188,0.059,0.067,0.0098,20242.393,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-24",24,24,3012,,0.007,0.001,1461,0.059,0.056,0.0046,24584.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-25",1,0.2,17.6,,0,0.001,9.32,0.059,0.004,0.056,156.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-28",16,15.1,2001.1,,0.005,0.001,1002.16,0.059,0.248,0.0629,16863.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-29",24,24,4227,,0.01,0.001,1898.3,0.059,0.065,0.004,31943.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-30",23,22.2,3257.2,,0.008,0.001,1506.54,0.059,0.053,0.0051,25349.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-06",13,12.82,1493.66,,0.004,0.001,737.758,0.059,0.073,0.0192,12412.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-07",21,20.38,2692.2,,0.007,0.001,1290.34,0.059,0.047,0.0048,21714.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-08",18,17.5,2711.06,,0.006,0.001,1273.422,0.059,0.077,0.0102,21426.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-13",13,11.43,1116.58,,0.003,0.001,623.868,0.0591,0.169,0.055,10495.148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-15",24,23.02,4846.02,,0.011,0.001,2134.05,0.059,0.126,0.0145,35913.204,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-16",17,16.08,2204.87,,0.005,0.001,1074.63,0.059,0.074,0.0134,18082.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-17",22,21.18,3505.44,,0.008,0.001,1570.816,0.059,0.061,0.0088,26432.956,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-19",16,15.09,2672.04,,0.006,0.001,1173.604,0.059,0.099,0.0221,19752.597,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-20",17,15.97,3402.51,,0.007,0.001,1444.906,0.059,0.067,0.0111,24311.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-21",16,13.03,1466.72,,0.004,0.001,736.034,0.059,0.056,0.0133,12384.292,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-22",6,4.7,460.36,,0.001,0.001,257.44,0.059,0.027,0.0247,4332.196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-24",20,18.62,4587.54,,0.01,0.001,1886.612,0.059,0.121,0.0217,31743.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-26",16,14.92,2112.76,,0.005,0.001,984.348,0.059,0.097,0.0248,16565.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-27",18,17.75,2505.5,,0.006,0.001,1170.425,0.059,0.059,0.0073,19694.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-28",24,24,4200,,0.009,0.001,1836.1,0.059,0.07,0.0045,30897.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-29",24,24,5220,,0.011,0.001,2213.2,0.059,0.098,0.0052,37240.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-30",24,24,4809,,0.01,0.001,2065.8,0.059,0.085,0.0048,34761.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-01-31",24,24,4662,,0.01,0.001,2020.4,0.059,0.088,0.005,33999.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-01",24,23.42,3788.04,,0.009,0.001,1694.546,0.059,0.075,0.0058,28512.762,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-03",19,18.68,3141.16,,0.007,0.001,1410.988,0.059,0.114,0.0189,23742.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-04",24,24,5696,,0.012,0.001,2377,0.059,0.089,0.0045,39995.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-05",24,24,6072,,0.013,0.001,2499.8,0.059,0.102,0.0048,42064.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-06",24,24,3631,,0.008,0.001,1656.8,0.059,0.067,0.0048,27878.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-07",24,24,3813,,0.009,0.001,1724.3,0.059,0.065,0.0044,29011.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-08",1,0.62,48.36,,0,0.001,31,0.059,0.004,0.017,521.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-11",20,19.9,3254.5,,0.007,0.001,1456.12,0.059,0.127,0.0187,24499.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-12",21,19.6,3067.85,,0.007,0.001,1398.585,0.059,0.076,0.0119,23532.705,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-13",24,24,4219,,0.009,0.001,1876.6,0.059,0.077,0.0048,31576.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-14",24,23.93,5424.95,,0.011,0.001,2270.361,0.059,0.096,0.0051,38201.001,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-17",21,20.38,3186.66,,0.007,0.001,1455.538,0.059,0.125,0.0214,24490.046,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-18",24,24,4948,,0.011,0.001,2116.4,0.059,0.095,0.0052,35612.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-19",24,24,5962,,0.012,0.001,2471.5,0.059,0.11,0.0053,41589.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-20",24,24,4159,,0.009,0.001,1829.8,0.059,0.07,0.0046,30787.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-21",24,24,4866,,0.01,0.001,2074.4,0.059,0.086,0.0048,34905.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-22",24,24,4726,,0.01,0.001,2014.6,0.059,0.076,0.0045,33901.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-23",1,0.13,11.18,,0,0.001,4.927,0.059,0.003,0.07,82.901,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-04",10,9.33,1909.98,,0.004,0.001,828.681,0.059,0.104,0.0443,13940.593,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-05",24,24,5502,,0.011,0.001,2270.7,0.059,0.086,0.0045,38204.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-06",24,24,5813,,0.012,0.001,2384.8,0.059,0.094,0.0047,40128.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-07",24,24,5624,,0.012,0.001,2317.9,0.059,0.086,0.0044,39005.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-08",24,24,5842,,0.012,0.001,2401.1,0.059,0.096,0.0048,40403.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-09",8,7.2,1194.6,,0.003,0.001,528.42,0.059,0.023,0.0098,8892.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-17",3,2.98,338.68,,0.001,0.001,179.868,0.059,0.076,0.0913,3027.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-18",24,24,4477,,0.01,0.001,1915.2,0.059,0.068,0.0043,32225.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-19",24,24,4898,,0.01,0.001,2071.6,0.059,0.074,0.0043,34859.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-20",24,24,4572,,0.01,0.001,1952.1,0.059,0.067,0.0041,32847.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-21",24,24,5391,,0.011,0.001,2232.4,0.059,0.078,0.0042,37563.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-22",24,24,5006,,0.011,0.001,2119,0.059,0.073,0.0041,35654,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-23",23,22.35,4074.1,,0.009,0.001,1754.23,0.059,0.064,0.005,29516.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-03-31",3,2.61,33.07,,0,0.001,78.191,0.059,0.127,0.196,1314.706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-07",24,23.33,4799.28,,0.01,0.001,2047.672,0.059,0.115,0.0152,34454.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-08",24,24,5758,,0.012,0.001,2368.3,0.059,0.086,0.0043,39852.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-09",24,24,6349,,0.013,0.001,2601.2,0.059,0.094,0.0043,43769.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-10",24,24,4059,,0.009,0.001,1788.9,0.059,0.07,0.0047,30098.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-11",10,8.28,1043.18,,0.003,0.001,525.661,0.059,0.067,0.0329,8845.413,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-12",8,7.15,1034.9,,0.002,0.001,488.665,0.059,0.022,0.0089,8223.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-15",10,9.2,961.4,,0.003,0.001,534.56,0.059,0.261,0.1017,8997.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-16",8,7.2,1541,,0.003,0.001,664.1,0.059,0.025,0.0089,11175.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-27",2,0.8,0.8,,0,0.001,20.584,0.059,0.035,0.199,346.463,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-06",12,10.3,2051.91,,0.005,0.001,893.559,0.059,0.082,0.0483,15036.211,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-07",24,24,4632,,0.01,0.001,2030.5,0.059,0.072,0.0043,34169.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-08",24,23.73,4255.61,,0.009,0.001,1830.426,0.059,0.08,0.0054,30801.631,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-26",7,4.94,93.24,,0.001,0.001,156.643,0.0591,0.246,0.1913,2636.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-27",20,18.5,3108.15,,0.007,0.001,1418.685,0.059,0.161,0.0277,23871.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-28",24,23.32,4714.04,,0.01,0.001,2028.324,0.059,0.089,0.0065,34126.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-29",11,9.35,1433.77,,0.003,0.001,677.559,0.059,0.095,0.0357,11399.759,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-30",4,3.13,522.89,,0.001,0.001,234.799,0.059,0.011,0.0175,3950.577,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-02",9,8.83,1684.45,,0.004,0.001,727.931,0.059,0.084,0.0299,12251.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-03",23,22.2,4063.4,,0.009,0.001,1735.84,0.059,0.079,0.0083,29206.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-04",9,8.52,1470.58,,0.003,0.001,646.678,0.059,0.062,0.0193,10882.102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-09",6,5.78,1095.92,,0.002,0.001,478.858,0.0592,0.094,0.0582,8056.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-10",24,24,5289,,0.011,0.001,2196.4,0.059,0.102,0.0054,36962.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-11",24,24,3811,,0.009,0.001,1684.4,0.059,0.077,0.0053,28341.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-12",2,1.4,221.2,,0,0.001,95.04,0.059,0.008,0.0145,1599.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-22",14,13.22,2826.32,,0.006,0.001,1225.624,0.0591,0.107,0.0265,20622.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-23",24,24,4448,,0.01,0.001,1915,0.059,0.08,0.0049,32223.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-24",24,24,4930,,0.01,0.001,2065.2,0.059,0.097,0.0056,34754.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-25",24,23.38,4442.84,,0.01,0.001,1945.474,0.059,0.083,0.0055,32731.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-26",13,12.77,2603.1,,0.006,0.001,1136.192,0.059,0.081,0.0158,19118.105,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-27",7,6.18,953.96,,0.002,0.001,438.022,0.059,0.02,0.0114,7369.604,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-06",11,9.86,1471.58,,0.003,0.001,666.59,0.059,0.117,0.0513,11218.922,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-07",11,10.98,2243.68,,0.005,0.001,948.908,0.059,0.082,0.0148,15968.504,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-08",24,23.38,4654.84,,0.01,0.001,1941.586,0.059,0.088,0.0057,32668.846,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-09",19,18.23,3639.91,,0.008,0.001,1523.902,0.059,0.078,0.0203,25642.161,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-10",24,24,5541,,0.011,0.001,2261.7,0.059,0.077,0.0041,38055.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-11",24,24,5127,,0.011,0.001,2119.7,0.059,0.074,0.0042,35668.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-12",24,24,4893,,0.01,0.001,2037.7,0.059,0.069,0.004,34290,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-13",23,22.88,4320.28,,0.009,0.001,1829.548,0.059,0.068,0.0045,30789.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-14",10,9.73,1753.49,,0.004,0.001,762.569,0.059,0.076,0.0292,12833.599,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-15",24,24,4702,,0.01,0.001,1966.9,0.059,0.069,0.0042,33093.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-16",24,24,4604,,0.01,0.001,1935,0.059,0.067,0.0041,32557,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-17",24,24,4783,,0.01,0.001,1989.8,0.059,0.071,0.0043,33481.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-18",24,24,4812,,0.01,0.001,2003.9,0.059,0.07,0.0042,33721,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-19",24,24,4863,,0.01,0.001,2014.9,0.059,0.071,0.0042,33905.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-20",24,24,4137,,0.009,0.001,1779.3,0.059,0.061,0.0041,29942.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-21",24,24,4448,,0.01,0.001,1890.6,0.059,0.068,0.0043,31814.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-22",15,13.36,3295.49,,0.007,0.001,1351.813,0.059,0.073,0.0211,22746.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-26",11,10.85,2285.75,,0.005,0.001,968.5,0.0591,0.092,0.0281,16295.295,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-27",24,24,4868,,0.01,0.001,2032.9,0.059,0.071,0.0042,34205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-28",24,24,4797,,0.01,0.001,1997.8,0.059,0.068,0.0041,33619.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-29",24,24,4906,,0.01,0.001,2034.1,0.059,0.073,0.0043,34231.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-30",24,24,4879,,0.01,0.001,2029,0.059,0.071,0.0042,34138.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-07-31",24,24,5257,,0.011,0.001,2159,0.059,0.075,0.0042,36326.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-01",24,23.2,4428.4,,0.009,0.001,1851.24,0.059,0.067,0.0059,31150.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-02",11,10.73,2377.94,,0.005,0.001,1001.849,0.059,0.058,0.0109,16856.452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-03",24,23.72,4788.72,,0.01,0.001,1996.9,0.059,0.072,0.0045,33604.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-04",14,12.89,2510.85,,0.006,0.001,1100.707,0.059,0.07,0.0176,18520.941,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-06",7,6.08,547.5,,0.002,0.001,319.138,0.0591,0.14,0.0794,5371.308,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-09",17,16.17,3067.17,,0.007,0.001,1366.285,0.059,0.192,0.041,22987.869,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-10",24,24,4244,,0.009,0.001,1847.7,0.059,0.063,0.0041,31094.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-11",22,21.18,3227.86,,0.007,0.001,1436.998,0.059,0.05,0.0053,24177.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-12",12,11.6,2316.82,,0.005,0.001,989.188,0.059,0.089,0.028,16642.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-13",24,24,4877,,0.01,0.001,2046.7,0.059,0.069,0.004,34440.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-14",24,23.5,4599.5,,0.01,0.001,1944.25,0.059,0.075,0.0055,32717.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-15",19,18.67,3749.83,,0.008,0.001,1611.364,0.059,0.08,0.0089,27117.159,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-16",15,14.13,2139.14,,0.005,0.001,963.827,0.059,0.046,0.0088,16219.435,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-17",24,24,4581,,0.01,0.001,1950.9,0.059,0.067,0.0041,32825.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-18",24,24,5311,,0.011,0.001,2210.2,0.059,0.074,0.004,37188.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-19",24,24,4554,,0.01,0.001,1946.4,0.059,0.065,0.004,32746.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-20",24,24,4701,,0.01,0.001,1985,0.059,0.067,0.004,33403,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-21",24,24,4653,,0.01,0.001,1967.7,0.059,0.067,0.0041,33113.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-22",24,24,4855,,0.01,0.001,2041.4,0.059,0.069,0.004,34353.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-23",24,24,4770,,0.01,0.001,2008.1,0.059,0.07,0.0042,33791.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-24",24,24,4803,,0.01,0.001,2024.1,0.059,0.068,0.004,34061,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-25",24,24,4661,,0.01,0.001,1977.7,0.059,0.067,0.004,33278,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-26",24,23.55,4318.8,,0.009,0.001,1854.775,0.059,0.068,0.0049,31207.97,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-27",21,20.09,3973.27,,0.009,0.001,1696.572,0.059,0.084,0.0136,28548.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-28",21,20.27,3852.32,,0.008,0.001,1646.806,0.059,0.085,0.0153,27710.641,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-29",17,15.82,2479.18,,0.006,0.001,1122.452,0.059,0.084,0.0214,18884.352,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-30",21,19.3,2771.3,,0.006,0.001,1282.61,0.059,0.056,0.0121,21583.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-08-31",24,23.2,2719.8,,0.007,0.001,1309.4,0.059,0.048,0.0055,22032.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-02",10,9.32,1783.92,,0.004,0.001,777.904,0.0591,0.084,0.0373,13088.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-03",24,24,5371,,0.011,0.001,2214.1,0.059,0.076,0.0041,37259.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-04",24,23.42,4571.12,,0.01,0.001,1941.44,0.059,0.07,0.0047,32668.528,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-05",21,20.19,4210.91,,0.009,0.001,1792.616,0.059,0.111,0.0169,30162.214,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-06",5,4.51,592.11,,0.001,0.001,294.542,0.0592,0.047,0.0414,4955.89,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-06",10,9.17,1994.77,,0.004,0.001,848.297,0.059,0.102,0.0439,14273.055,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-07",10,8.82,1510.09,,0.003,0.001,669.483,0.0591,0.062,0.0314,11264.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-08",20,19.52,4108.96,,0.009,0.001,1760.42,0.059,0.084,0.0116,29623.352,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-09",24,24,5877,,0.012,0.001,2422,0.059,0.085,0.0042,40752.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-10",24,24,5091,,0.011,0.001,2125.7,0.059,0.075,0.0043,35769,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-11",24,24,5407,,0.011,0.001,2240.2,0.059,0.078,0.0042,37696.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-12",24,24,3841,,0.009,0.001,1704.4,0.059,0.057,0.004,28679.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-13",24,23.17,3075.24,,0.007,0.001,1417.843,0.059,0.053,0.006,23854.794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-14",12,11.27,2157.93,,0.005,0.001,942.023,0.059,0.058,0.0109,15850.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-15",14,13.35,2790.1,,0.006,0.001,1192.849,0.059,0.074,0.0151,20071.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-16",13,12.65,2087.9,,0.005,0.001,918.605,0.059,0.062,0.0146,15454.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-17",12,9.65,1550.53,,0.004,0.001,694.163,0.059,0.053,0.0285,11683.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-18",10,9.72,2175.64,,0.005,0.001,924.776,0.059,0.079,0.0292,15560.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-19",24,24,5074,,0.011,0.001,2161.2,0.059,0.074,0.0041,36367.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-20",24,24,4758,,0.01,0.001,2019.8,0.059,0.075,0.0044,33983.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-21",24,24,5262,,0.011,0.001,2190.8,0.059,0.079,0.0043,36862.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-22",24,24,4403,,0.01,0.001,1901.4,0.059,0.068,0.0043,31996.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-23",24,24,5858,,0.012,0.001,2399.3,0.059,0.083,0.0041,40370.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-24",24,24,5912,,0.012,0.001,2420.9,0.059,0.085,0.0042,40736,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-25",24,24,6062,,0.013,0.001,2476.3,0.059,0.085,0.0041,41671,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-26",24,24,5314,,0.011,0.001,2223.4,0.059,0.086,0.0046,37411.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-27",24,24,5247,,0.011,0.001,2186.3,0.059,0.074,0.004,36788.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-28",24,24,5560,,0.012,0.001,2294,0.059,0.08,0.0042,38599.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-29",24,24,5041,,0.011,0.001,2109.2,0.059,0.074,0.0042,35491.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-30",24,24,5536,,0.012,0.001,2282,0.059,0.083,0.0043,38398.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-10-31",24,24,6338,,0.013,0.001,2574,0.059,0.09,0.0042,43316.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-01",24,24,5761,,0.012,0.001,2402,0.059,0.086,0.0043,40420.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-02",24,24,4373,,0.01,0.001,1908.1,0.059,0.07,0.0043,32110.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-03",24,24,4759,,0.01,0.001,2044.7,0.059,0.071,0.0042,34404.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-04",24,24,4268,,0.009,0.001,1876.8,0.059,0.066,0.0042,31580.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-05",21,19.98,4662.15,,0.01,0.001,1967.915,0.059,0.091,0.0078,33115.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-06",24,24,6338,,0.013,0.001,2623.3,0.059,0.09,0.0041,44141.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-07",1,0.28,15.4,,0,0.001,12.908,0.059,0.004,0.037,217.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-09",19,18.73,3891.76,,0.008,0.001,1675.099,0.059,0.113,0.0168,28184.771,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-10",24,24,4788,,0.01,0.001,2069.8,0.059,0.073,0.0042,34824.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-11",11,10.71,2033.72,,0.005,0.001,891.478,0.059,0.056,0.0107,14999.371,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-12",24,24,4706,,0.01,0.001,2009.5,0.059,0.076,0.0045,33813.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-13",3,2.18,385.3,,0.001,0.001,167.162,0.059,0.009,0.022,2813.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-17",9,7.54,1087.08,,0.003,0.001,516.206,0.0591,0.088,0.0518,8684.384,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-18",10,9.82,1507.8,,0.004,0.001,695.642,0.059,0.042,0.0085,11705.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-19",6,3.32,297.25,,0.001,0.001,176.13,0.0593,0.031,0.0573,2963.163,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-20",13,12.37,2277.37,,0.005,0.001,1022.02,0.0591,0.078,0.0254,17196.953,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-21",24,23.48,4172.32,,0.009,0.001,1850.052,0.059,0.076,0.0053,31128.504,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-07",14,13.28,1649.28,,0.004,0.001,855.384,0.059,0.297,0.0771,14393.764,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-08",24,24,4187,,0.01,0.001,1905.2,0.059,0.068,0.0043,32058.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-09",24,24,4143,,0.009,0.001,1880.2,0.059,0.071,0.0044,31637.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-10",2,1.2,201,,0,0.001,89.12,0.059,0.009,0.037,1498.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-13",11,10,1271.87,,0.003,0.001,622.481,0.059,0.105,0.035,10473.287,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-14",11,10.17,1599.74,,0.004,0.001,757.788,0.059,0.063,0.02,12750.773,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-15",13,12.17,2413.02,,0.005,0.001,1081.358,0.059,0.085,0.0231,18194.043,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-17",19,18,3007.17,,0.007,0.001,1353.193,0.059,0.113,0.0215,22769.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-21",8,7.52,925.89,,0.002,0.001,454.818,0.059,0.079,0.0424,7652.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-24",21,19.82,2155.92,,0.006,0.001,1097.308,0.059,0.101,0.0212,18463.81,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-29",15,14.35,2683.51,,0.006,0.001,1185.867,0.059,0.106,0.0247,19958.063,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-30",17,16.05,2565.05,,0.006,0.001,1163.765,0.059,0.063,0.0088,19581.186,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mountainview Generating Station",358,"4-2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-18",11,10.28,0,,0,0,19.532,0.0609,0.019,0.116,321.776,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-19",24,24,0,,0,0,45.6,0.061,0.044,0.116,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-20",24,24,0,,0,0,45.6,0.061,0.044,0.116,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-21",24,24,0,,0,0,45.6,0.061,0.044,0.116,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-22",24,24,0,,0,0,45.6,0.061,0.044,0.116,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-23",24,24,0,,0,0,45.6,0.061,0.044,0.116,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-24",24,24,0,,0,0,45.6,0.061,0.021,0.0554,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-25",24,24,0,,0,0,45.6,0.061,0.003,0.008,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-26",24,24,0,,0,0,45.6,0.061,0.003,0.008,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-27",24,24,0,,0,0,45.6,0.061,0.003,0.0079,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-28",24,24,0,,0,0,45.6,0.061,0.005,0.0126,751.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-29",12,11.85,0,,0,0,22.515,0.061,0.002,0.0106,370.905,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-04-30",15,14.8,191,,0.001,0.0007,149.48,0.0595,0.07,0.0577,2512.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-01",24,24,398,,0.001,0.0009,282.7,0.0595,0.117,0.0493,4756.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-02",8,7.22,0,,0,0,13.591,0.0581,0.002,0.0153,234.465,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-03",24,24,122,,0,0.0002,124.3,0.0585,0.052,0.0492,2103.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-04",24,24,392,,0.001,0.0005,288.1,0.0595,0.096,0.0396,4847.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-05",24,24,395,,0.001,0.0003,309.7,0.0594,0.133,0.0504,5209.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-06",24,24,397,,0.001,0,323.6,0.0592,0.159,0.0583,5449.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-07",24,24,397,,0.001,0.0001,318.4,0.0595,0.116,0.0431,5354,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-08",24,24,468,,0.002,0.0009,330.5,0.0593,0.143,0.0489,5565.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-09",24,24,385,,0.001,0.0007,283,0.0593,0.066,0.0276,4762,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-10",24,24,384,,0.001,0.0008,282,0.0594,0.07,0.0295,4743.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-11",24,24,384,,0.001,0.0009,282.2,0.0595,0.082,0.0346,4745,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-12",24,24,384,,0.001,0.0008,282.2,0.0593,0.087,0.0367,4750.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-13",24,24,384,,0.001,0.0008,283.3,0.0594,0.085,0.0355,4767.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-14",24,24,386,,0.001,0.0004,298,0.0595,0.095,0.0378,5012.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-15",24,24,389,,0.001,0,310.3,0.0594,0.095,0.0363,5218.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-16",24,24,384,,0.001,0,311.5,0.0592,0.098,0.0373,5247.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-17",24,24,384,,0.001,0,312.4,0.0592,0.098,0.0371,5260.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-18",24,24,384,,0.001,0,311.8,0.0595,0.092,0.0353,5243.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-19",24,24,384,,0.001,0,309.9,0.0595,0.089,0.034,5213.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-20",24,24,384,,0.001,0,310.1,0.0595,0.089,0.034,5217.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-21",24,24,384,,0.001,0,309.5,0.0592,0.092,0.0353,5212.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-22",24,24,384,,0.001,0,310.4,0.0594,0.095,0.0365,5224.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-23",24,24,383,,0.001,0,308.9,0.0592,0.096,0.0368,5199.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-24",24,24,384,,0.001,0,308.4,0.0592,0.093,0.0358,5189.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-25",24,24,381,,0.001,0,308.9,0.0595,0.095,0.0366,5194.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-26",24,24,384,,0.001,0,309,0.0594,0.091,0.0349,5198.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-27",24,24,384,,0.001,0,308.9,0.0595,0.09,0.0345,5196.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-28",24,24,384,,0.001,0,309.7,0.0593,0.093,0.0358,5210,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-29",24,24,384,,0.001,0,307.4,0.0594,0.094,0.0362,5171.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-30",24,24,384,,0.001,0,306.1,0.0595,0.093,0.036,5148.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-05-31",24,24,384,,0.001,0,305.6,0.0592,0.093,0.036,5151.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-01",24,24,384,,0.001,0,304.1,0.0594,0.091,0.0357,5114.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-02",24,24,432,,0.001,0.0001,337.1,0.0593,0.125,0.0413,5673.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-03",24,24,400,,0.001,0.0001,314.5,0.0592,0.102,0.0384,5290.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-04",24,24,404,,0.001,0.0002,313.3,0.0593,0.093,0.0341,5275.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-05",24,24,384,,0.001,0,312.4,0.0591,0.089,0.034,5263,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-06",24,24,384,,0.001,0,313.5,0.0592,0.089,0.0335,5278.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-07",24,24,384,,0.001,0,313.3,0.0591,0.087,0.0329,5277.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-08",24,24,384,,0.001,0,313.6,0.0593,0.091,0.0346,5277.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-09",24,24,485,,0.002,0.0003,374.8,0.0592,0.121,0.0374,6310.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-10",24,24,417,,0.001,0.0001,336.9,0.0592,0.097,0.0342,5672.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-11",24,24,388,,0.001,0,317.4,0.0593,0.089,0.0335,5340.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-12",24,24,384,,0.001,0,313.7,0.0592,0.082,0.0312,5281.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-13",24,24,384,,0.001,0,314.4,0.0594,0.095,0.036,5290.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-14",24,24,384,,0.001,0,315.4,0.0592,0.097,0.0364,5311.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-15",24,24,384,,0.001,0,316.2,0.0592,0.083,0.0313,5325.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-16",24,24,384,,0.001,0,314.5,0.0592,0.076,0.0287,5293.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-17",24,24,384,,0.001,0,315,0.0596,0.076,0.0288,5294.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-18",24,24,384,,0.001,0,314.2,0.0595,0.076,0.0286,5285.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-19",24,24,384,,0.001,0,314.7,0.0595,0.076,0.0289,5292.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-20",24,24,384,,0.001,0,313.9,0.0593,0.073,0.0275,5285.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-21",24,24,384,,0.001,0,311.3,0.0594,0.069,0.0265,5239,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-22",24,24,385,,0.001,0,311.9,0.0594,0.069,0.0262,5247.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-23",24,24,528,,0.002,0.001,395.4,0.0592,0.127,0.0381,6657.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-24",24,24,528,,0.002,0.001,393.7,0.0592,0.126,0.0379,6627.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-25",24,24,528,,0.002,0.001,395.8,0.0593,0.127,0.0381,6656.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-26",24,24,528,,0.002,0.001,394,0.0592,0.126,0.038,6627.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-27",24,24,528,,0.002,0.001,393.9,0.0591,0.128,0.0387,6629.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-28",24,24,528,,0.002,0.001,392.7,0.0591,0.129,0.039,6607.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-29",24,24,528,,0.002,0.001,393.5,0.0595,0.13,0.0392,6617.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-06-30",24,24,528,,0.002,0.001,393.7,0.0592,0.13,0.0394,6624.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-01",24,24,562,,0.002,0.001,414.9,0.0593,0.137,0.039,6979,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-02",24,24,556,,0.002,0.001,416.3,0.0593,0.115,0.0325,7005.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-03",24,24,528,,0.002,0.001,397.8,0.0593,0.104,0.031,6697,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-04",24,24,528,,0.002,0.001,399.1,0.0592,0.126,0.0375,6718.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-05",24,24,528,,0.002,0.001,398.9,0.0592,0.134,0.0398,6713.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-06",24,24,528,,0.002,0.001,399.2,0.0593,0.135,0.0401,6713.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-07",24,24,528,,0.002,0.001,401.4,0.0592,0.124,0.0367,6755.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-08",24,24,528,,0.002,0.001,404,0.0595,0.117,0.0345,6791.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-09",24,24,528,,0.002,0.001,404.8,0.0593,0.116,0.034,6812.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-10",24,24,528,,0.002,0.001,405.6,0.0591,0.115,0.0338,6827,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-11",24,24,570,,0.002,0.001,427.2,0.0595,0.124,0.0345,7183.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-12",24,24,569,,0.002,0.001,425.5,0.0593,0.137,0.038,7160.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-13",24,24,573,,0.002,0.001,427.6,0.0591,0.124,0.0346,7198.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-14",24,24,528,,0.002,0.001,401.1,0.0593,0.126,0.0373,6747.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-15",24,24,528,,0.002,0.001,399.8,0.0592,0.118,0.0352,6728.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-16",24,24,528,,0.002,0.001,400.8,0.0594,0.115,0.0342,6744,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-17",24,24,528,,0.002,0.001,403,0.0593,0.112,0.0329,6781.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-18",24,23.67,439.19,,0.002,0.001,344.223,0.0593,0.117,0.044,5791.827,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-19",24,24,265,,0.001,0.001,237.2,0.0593,0.076,0.038,3993.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-20",24,24,433,,0.002,0.001,341,0.0594,0.096,0.0331,5736.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-21",24,24,536,,0.002,0.001,395.8,0.0592,0.116,0.0347,6662.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-22",24,24,531,,0.002,0.001,402,0.0594,0.125,0.037,6762.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-23",24,24,528,,0.002,0.001,403.9,0.0592,0.129,0.038,6803.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-24",24,24,528,,0.002,0.001,404,0.0593,0.117,0.0343,6798.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-25",24,24,528,,0.002,0.001,403.6,0.0593,0.118,0.0348,6788.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-26",24,24,528,,0.002,0.001,403.4,0.0594,0.118,0.0347,6788,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-27",24,24,528,,0.002,0.001,402.1,0.0592,0.114,0.0338,6773.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-28",24,24,528,,0.002,0.001,401.7,0.0594,0.11,0.0325,6756.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-29",24,24,528,,0.002,0.001,401,0.0593,0.108,0.032,6746.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-30",24,24,569,,0.002,0.001,423.9,0.0594,0.119,0.0332,7130.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-07-31",24,24,552,,0.002,0.001,406.9,0.0592,0.109,0.0317,6846.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-01",24,24,578,,0.002,0.001,427.5,0.0593,0.134,0.0369,7193.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-02",24,24,528,,0.002,0.001,404,0.0594,0.115,0.0338,6795.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-03",24,24,580,,0.002,0.001,428.1,0.0592,0.126,0.0348,7203.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-04",24,24,528,,0.002,0.001,402.7,0.0591,0.114,0.0337,6779.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-05",24,24,528,,0.002,0.001,402.4,0.0593,0.114,0.0338,6775.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-06",24,24,528,,0.002,0.001,401.9,0.0592,0.116,0.0343,6765.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-07",24,24,528,,0.002,0.001,401.6,0.0591,0.116,0.0343,6765.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-08",24,24,528,,0.002,0.001,405.3,0.0593,0.12,0.0353,6820.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-09",24,24,528,,0.002,0.001,405.1,0.0594,0.116,0.0342,6812.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-10",24,24,528,,0.002,0.001,405.4,0.0595,0.117,0.0344,6819.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-11",24,24,528,,0.002,0.001,404.4,0.0593,0.112,0.0328,6805.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-12",24,24,528,,0.002,0.001,405.6,0.0591,0.113,0.033,6828.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-13",24,24,536,,0.002,0.001,407.1,0.0592,0.111,0.0324,6854.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-14",24,24,543,,0.002,0.001,411.4,0.0593,0.109,0.0314,6924.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-15",24,24,578,,0.002,0.001,432.6,0.0593,0.114,0.0313,7280.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-16",24,24,546,,0.002,0.001,414,0.0592,0.107,0.0305,6967.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-17",24,24,530,,0.002,0.001,403.4,0.0592,0.098,0.029,6790.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-18",24,24,557,,0.002,0.001,414.6,0.0592,0.098,0.0278,6977.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-19",24,24,564,,0.002,0.001,426.8,0.0593,0.103,0.0282,7180.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-20",24,24,528,,0.002,0.001,406.7,0.0592,0.091,0.0267,6844.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-21",24,24,528,,0.002,0.001,405.1,0.0593,0.096,0.0282,6817.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-22",24,24,528,,0.002,0.001,405.4,0.0593,0.103,0.0303,6824.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-23",24,24,566,,0.002,0.001,430.3,0.0593,0.118,0.0322,7239.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-24",24,24,528,,0.002,0.001,405.3,0.0592,0.092,0.0268,6822.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-25",24,24,540,,0.002,0.001,410.9,0.0593,0.098,0.0283,6913.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-26",24,24,528,,0.002,0.001,405,0.0594,0.092,0.027,6814,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-27",24,24,528,,0.002,0.001,404.3,0.0592,0.094,0.0275,6803.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-28",24,24,553,,0.002,0.001,414.6,0.0593,0.104,0.0294,6977.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-29",24,24,528,,0.002,0.001,400.3,0.0593,0.094,0.0279,6735,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-30",24,24,528,,0.002,0.001,399.5,0.0595,0.094,0.028,6719.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-08-31",24,24,528,,0.002,0.001,400.7,0.0595,0.096,0.0284,6738.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-01",24,24,528,,0.002,0.001,393.6,0.0592,0.09,0.027,6624.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-02",24,24,528,,0.002,0.001,370.4,0.0593,0.075,0.024,6237.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-03",24,24,528,,0.002,0.001,400.1,0.0593,0.095,0.0283,6731.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-04",24,24,528,,0.002,0.001,419.8,0.0593,0.114,0.032,7064.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-05",24,24,613,,0.002,0.001,478.5,0.0593,0.165,0.0405,8048.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-06",24,24,603,,0.002,0.001,484.5,0.059,0.14,0.0338,8157.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-07",24,24,528,,0.002,0.001,439.4,0.0594,0.104,0.0282,7393.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-08",24,24,528,,0.002,0.001,436.7,0.0593,0.117,0.0318,7349.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-09",24,24,528,,0.002,0.001,410.1,0.0594,0.102,0.0295,6898.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-10",24,24,528,,0.002,0.001,408.4,0.0593,0.105,0.0307,6873.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-11",24,24,541,,0.002,0.001,414.1,0.0595,0.111,0.0315,6961.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-12",24,24,528,,0.002,0.001,405.4,0.0592,0.106,0.0312,6822.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-13",24,24,544,,0.002,0.001,411.8,0.0593,0.119,0.0342,6930.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-14",24,24,528,,0.002,0.001,400.5,0.0594,0.123,0.0364,6734.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-15",24,24,528,,0.002,0.001,402.1,0.0595,0.115,0.0339,6759.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-16",24,24,528,,0.002,0.001,400.6,0.0594,0.117,0.0348,6737.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-17",24,24,528,,0.002,0.001,404.3,0.0592,0.125,0.0368,6806.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-18",24,24,528,,0.002,0.001,403.9,0.0593,0.113,0.0333,6797,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-19",24,24,528,,0.002,0.001,404.9,0.0594,0.103,0.0303,6811.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-20",24,24,528,,0.002,0.001,404.3,0.0596,0.103,0.0304,6796.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-21",24,24,528,,0.002,0.001,403,0.0596,0.102,0.03,6775.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-22",24,24,528,,0.002,0.001,400.9,0.059,0.101,0.0298,6756.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-23",24,24,528,,0.002,0.001,401.1,0.0593,0.101,0.03,6749.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-24",24,24,528,,0.002,0.001,400.8,0.0593,0.102,0.0301,6744.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-25",24,24,528,,0.002,0.001,400.2,0.0593,0.099,0.0293,6733.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-26",24,24,528,,0.002,0.001,399.4,0.0592,0.097,0.0288,6724.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-27",24,24,528,,0.002,0.001,400.8,0.0593,0.09,0.0268,6746.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-28",24,24,528,,0.002,0.001,402.1,0.0594,0.089,0.0265,6765.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-29",24,24,528,,0.002,0.001,401.9,0.0593,0.09,0.0267,6764.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-09-30",24,24,528,,0.002,0.001,400,0.0593,0.089,0.0266,6730.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-01",22,21.14,337.85,,0.002,0.0008,271.507,0.0591,0.183,0.0725,4573.124,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-02",24,24,520,,0.002,0.001,399.6,0.0594,0.135,0.0407,6722.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-03",24,24,528,,0.002,0.001,399.7,0.0593,0.097,0.0289,6724.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-04",24,24,528,,0.002,0.001,400.2,0.0593,0.094,0.0279,6733.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-05",24,24,528,,0.002,0.001,400.6,0.0592,0.089,0.0265,6744.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-06",24,24,528,,0.002,0.001,400.9,0.0594,0.089,0.0265,6742.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-07",24,24,528,,0.002,0.001,402,0.0593,0.089,0.0264,6765.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-08",11,10.5,230,,0.001,0.001,177,0.0592,0.039,0.0261,2978.75,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-13",8,7.93,0,,0,0,14.274,0.058,0.002,0.0134,245.13,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-14",24,24,274,,0.001,0.0006,236,0.0588,0.08,0.0362,3977.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-15",24,24,508,,0.002,0.001,398.5,0.0597,0.087,0.0261,6696.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-16",24,24,504,,0.002,0.001,395.7,0.0594,0.084,0.0252,6658.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-17",24,24,523,,0.002,0.001,399.8,0.0593,0.083,0.0248,6726.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-18",24,24,528,,0.002,0.001,401.4,0.0592,0.084,0.0249,6754.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-19",24,24,528,,0.002,0.001,400.6,0.0593,0.084,0.025,6740.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-20",24,24,528,,0.002,0.001,400.5,0.0593,0.085,0.0251,6739.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-21",24,24,528,,0.002,0.001,400.1,0.0593,0.084,0.0251,6731.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-22",24,24,528,,0.002,0.001,400.3,0.0593,0.084,0.025,6733.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-23",24,24,528,,0.002,0.001,401.6,0.0592,0.09,0.0266,6760.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-24",24,24,528,,0.002,0.001,401.5,0.0593,0.091,0.027,6758.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-25",24,24,528,,0.002,0.001,401.8,0.0593,0.098,0.0291,6764.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-26",24,24,528,,0.002,0.001,398.2,0.0593,0.104,0.031,6699.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-27",24,24,528,,0.002,0.001,398,0.0593,0.103,0.0308,6696.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-28",24,24,528,,0.002,0.001,400.4,0.0591,0.1,0.0296,6742.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-29",24,24,528,,0.002,0.001,401.9,0.0593,0.101,0.0298,6763.1,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-30",24,24,528,,0.002,0.001,401,0.0592,0.101,0.0298,6746.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-10-31",24,24,528,,0.002,0.001,402.1,0.0593,0.102,0.0301,6765.9,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-01",24,24,528,,0.002,0.001,402.8,0.0592,0.102,0.03,6782.2,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-02",24,24,528,,0.002,0.001,401.9,0.0593,0.096,0.0283,6764.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-03",24,24,532,,0.002,0.001,404.7,0.0595,0.096,0.0282,6804.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-04",24,24,528,,0.002,0.001,404.4,0.0594,0.096,0.0283,6801.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-05",24,24,528,,0.002,0.001,404.4,0.0593,0.101,0.0296,6804.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-06",24,24,528,,0.002,0.001,403.4,0.0592,0.094,0.0278,6791.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-07",24,24,528,,0.002,0.001,399.8,0.0593,0.093,0.0276,6727.4,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-08",24,24,528,,0.002,0.001,399.3,0.0593,0.091,0.0271,6715.8,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-09",24,24,528,,0.002,0.001,399.9,0.0593,0.097,0.0288,6727.5,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-10",24,24,528,,0.002,0.001,401.5,0.0593,0.102,0.0303,6754,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-11",24,24,528,,0.002,0.001,402.4,0.0594,0.103,0.0305,6769.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-12",24,24,528,,0.002,0.001,402.5,0.0593,0.102,0.0301,6773.6,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-13",24,24,528,,0.002,0.001,402,0.0593,0.101,0.0298,6764,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-14",24,24,528,,0.002,0.001,405.8,0.0593,0.097,0.0285,6830.7,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-15",24,24,528,,0.002,0.001,403.8,0.0595,0.098,0.0288,6790.3,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-16",16,15.7,345.4,,0.002,0.001,265.53,0.0593,0.065,0.0289,4468.09,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil, Other Gas","Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only)",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-08",10,9.5,0,,0,0,18.05,0.061,0.001,0.0034,298.3,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-09",24,24,0,,0,0,45.6,0.061,0.002,0.0057,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-10",24,24,0,,0,0,45.6,0.061,0.003,0.0081,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-11",24,24,0,,0,0,45.6,0.061,0.003,0.0081,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-12",24,24,0,,0,0,45.6,0.061,0.003,0.0079,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-13",24,24,0,,0,0,45.6,0.061,0.003,0.0093,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-14",24,24,0,,0,0,45.6,0.061,0.004,0.0105,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-15",24,24,0,,0,0,45.6,0.061,0.002,0.0062,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-16",24,24,0,,0,0,45.6,0.061,0.003,0.007,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-17",24,24,0,,0,0,45.6,0.061,0.005,0.0135,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-18",24,24,0,,0,0,45.6,0.061,0.003,0.0076,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-19",24,24,0,,0,0,45.6,0.061,0.003,0.0068,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-20",24,24,0,,0,0,45.6,0.061,0.003,0.007,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-21",24,24,0,,0,0,45.6,0.0609,0.003,0.007,754.3,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-22",24,24,0,,0,0,45.6,0.061,0.003,0.007,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-23",24,24,0,,0,0,45.6,0.061,0.003,0.007,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-24",24,24,0,,0,0,45.6,0.061,0.003,0.0071,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-25",24,24,0,,0,0,45.6,0.061,0.003,0.0071,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-26",24,24,0,,0,0,45.6,0.061,0.003,0.0073,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-27",24,24,0,,0,0,45.6,0.061,0.003,0.0078,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-28",24,24,0,,0,0,45.6,0.061,0.003,0.0079,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-02-29",24,24,0,,0,0,45.6,0.061,0.003,0.007,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-01",24,24,0,,0,0,45.6,0.061,0.003,0.007,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-02",24,24,0,,0,0,45.6,0.061,0.003,0.0071,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-03",24,24,0,,0,0,45.6,0.061,0.003,0.0071,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-04",24,24,0,,0,0,45.6,0.061,0.002,0.0064,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-05",24,24,0,,0,0,45.6,0.061,0.002,0.0065,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-06",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-07",24,24,0,,0,0,45.6,0.061,0.002,0.0063,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-08",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-09",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-10",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-11",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-12",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-13",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-14",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-15",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-16",24,24,0,,0,0,45.6,0.061,0.002,0.0062,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-17",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-18",24,24,0,,0,0,45.6,0.061,0.002,0.0066,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-19",24,24,0,,0,0,45.6,0.061,0.002,0.0063,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-20",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-21",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-22",24,24,0,,0,0,45.6,0.061,0.002,0.0062,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-23",24,24,0,,0,0,42.8,0.0616,0.002,0.0061,707,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-24",24,24,0,,0,0,45,0.0609,0.004,0.0095,744.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-25",24,24,0,,0,0,43.3,0.061,0.003,0.0072,717,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-26",24,24,0,,0,0,45.6,0.061,0.003,0.008,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-27",24,24,0,,0,0,45.6,0.061,0.003,0.0068,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-28",24,24,0,,0,0,45.6,0.061,0.002,0.0063,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-29",24,24,0,,0,0,45.6,0.061,0.003,0.0068,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-30",24,24,0,,0,0,45.6,0.061,0.003,0.007,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-03-31",24,24,0,,0,0,45.6,0.061,0.003,0.0068,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-01",24,24,0,,0,0,45.6,0.061,0.002,0.0064,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-02",24,24,0,,0,0,45.6,0.061,0.002,0.0065,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-03",24,24,0,,0,0,45.6,0.061,0.002,0.0065,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-04",24,24,0,,0,0,45.6,0.061,0.002,0.0062,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-05",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-06",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-07",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-08",24,24,0,,0,0,45.6,0.061,0.003,0.007,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-09",24,24,0,,0,0,45.6,0.061,0.003,0.007,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-10",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-11",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-12",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-13",24,24,0,,0,0,45.6,0.061,0.003,0.007,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-14",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-15",24,24,0,,0,0,45.6,0.061,0.003,0.007,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-16",24,24,0,,0,0,45.6,0.061,0.005,0.0129,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-17",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-18",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-19",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-20",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-21",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-22",24,24,0,,0,0,45.6,0.061,0.004,0.0095,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-23",24,24,0,,0,0,45.6,0.061,0.003,0.0068,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-24",24,24,0,,0,0,45.6,0.061,0.003,0.0074,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-25",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-26",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-27",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-28",24,24,0,,0,0,45.6,0.061,0.003,0.0073,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-29",24,24,0,,0,0,45.6,0.061,0.002,0.006,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-04-30",24,24,0,,0,0,45.6,0.061,0.002,0.0066,751.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-01",24,24,0,,0,0,43.2,0.058,0.002,0.005,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-02",24,24,0,,0,0,43.2,0.058,0.002,0.0058,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-03",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-04",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-05",24,24,0,,0,0,43.2,0.058,0.002,0.0058,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-06",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-07",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-08",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-09",24,24,0,,0,0,43.2,0.058,0.002,0.0055,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-10",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-11",24,24,0,,0,0,43.2,0.058,0.002,0.0053,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-12",24,24,0,,0,0,43.2,0.058,0.002,0.0065,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-13",24,24,0,,0,0,43.2,0.058,0.003,0.0068,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-14",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-15",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-16",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-17",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-18",24,24,0,,0,0,43.2,0.058,0.002,0.0065,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-19",24,24,0,,0,0,43.2,0.058,0.003,0.007,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-20",24,24,0,,0,0,43.2,0.058,0.002,0.0058,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-21",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-22",24,24,0,,0,0,43.2,0.058,0.002,0.0067,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-23",24,24,0,,0,0,43.2,0.058,0.002,0.0065,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-24",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-25",24,24,0,,0,0,43.2,0.058,0.002,0.0059,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-26",24,24,0,,0,0,43.2,0.058,0.002,0.0062,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-27",24,24,0,,0,0,43.2,0.058,0.003,0.0085,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-28",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-29",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-30",24,24,0,,0,0,43.2,0.058,0.002,0.0056,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-05-31",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-01",24,24,0,,0,0,43.2,0.058,0.002,0.0056,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-02",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-03",24,24,0,,0,0,43.2,0.058,0.002,0.0054,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-04",24,24,0,,0,0,43.2,0.058,0.002,0.0052,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-05",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-06",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-07",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-08",24,24,0,,0,0,43.2,0.058,0.002,0.0059,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-09",24,24,0,,0,0,43.2,0.058,0.002,0.0061,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-10",24,24,0,,0,0,43.2,0.058,0.002,0.0058,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-11",24,24,0,,0,0,43.2,0.058,0.002,0.0051,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-12",24,24,0,,0,0,43.2,0.058,0.002,0.0058,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-13",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-14",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-15",24,24,0,,0,0,43.2,0.058,0.002,0.0065,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-16",24,24,0,,0,0,43.2,0.058,0.003,0.0083,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-17",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-18",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-19",24,24,0,,0,0,43.2,0.058,0.002,0.0058,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-20",24,24,0,,0,0,43.2,0.058,0.002,0.0059,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-21",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-22",24,24,0,,0,0,43.2,0.058,0.002,0.0059,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-23",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-24",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-25",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-26",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-27",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-28",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-29",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-06-30",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-01",24,24,0,,0,0,43.2,0.059,0.002,0.0057,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-02",24,24,0,,0,0,43.2,0.059,0.002,0.0058,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-03",24,24,0,,0,0,43.2,0.059,0.002,0.0055,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-04",24,24,0,,0,0,43.2,0.059,0.002,0.0052,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-05",24,24,0,,0,0,43.2,0.059,0.002,0.0057,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-06",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-07",24,24,0,,0,0,43.2,0.059,0.002,0.0059,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-08",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-09",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-10",24,24,0,,0,0,43.2,0.059,0.002,0.0054,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-11",24,24,0,,0,0,43.2,0.059,0.002,0.0054,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-12",24,24,0,,0,0,43.2,0.059,0.002,0.0058,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-13",24,24,0,,0,0,43.2,0.059,0.002,0.0054,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-14",24,24,0,,0,0,43.2,0.059,0.002,0.0058,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-15",24,24,0,,0,0,43.2,0.059,0.002,0.0058,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-16",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-17",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-18",22,21.21,0,,0,0,38.516,0.0591,0.003,0.0089,655.802,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-19",20,18.98,0,,0,0,34.091,0.059,0.002,0.0067,581.664,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-20",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-21",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-22",24,24,0,,0,0,43.2,0.059,0.003,0.0083,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-23",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-24",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-25",24,24,0,,0,0,43.2,0.059,0.002,0.0059,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-26",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-27",24,24,0,,0,0,43.2,0.059,0.002,0.0056,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-28",24,24,0,,0,0,43.2,0.059,0.002,0.0059,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-29",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-30",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-07-31",24,24,0,,0,0,43.2,0.059,0.002,0.006,736.8,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-01",24,24,0,,0,0,43.2,0.058,0.002,0.005,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-02",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-03",24,24,0,,0,0,43.2,0.058,0.002,0.0055,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-04",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-05",24,24,0,,0,0,43.2,0.058,0.002,0.0053,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-06",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-07",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-08",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-09",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-10",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-11",24,24,0,,0,0,43.2,0.058,0.002,0.0055,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-12",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-13",24,24,0,,0,0,43.2,0.058,0.002,0.0057,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-14",24,24,0,,0,0,43.2,0.058,0.002,0.0054,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-15",24,24,0,,0,0,43.2,0.058,0.002,0.0056,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-16",24,24,0,,0,0,43.2,0.058,0.002,0.0052,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-17",24,24,0,,0,0,43.2,0.058,0.002,0.0059,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-18",24,24,0,,0,0,43.2,0.058,0.002,0.0056,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-19",24,24,0,,0,0,43.2,0.058,0.002,0.0056,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-20",24,24,0,,0,0,43.2,0.058,0.002,0.0055,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-21",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-22",24,24,0,,0,0,43.2,0.058,0.002,0.0052,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-23",24,24,0,,0,0,43.2,0.058,0.002,0.005,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-24",24,24,0,,0,0,43.2,0.058,0.002,0.0051,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-25",24,24,0,,0,0,43.2,0.058,0.002,0.0058,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-26",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-27",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-28",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-29",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-30",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-08-31",24,24,0,,0,0,43.2,0.058,0.002,0.006,739.2,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-01",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-02",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-03",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-04",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-05",24,24,0,,0,0,43.2,0.058,0.002,0.0055,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-06",24,24,0,,0,0,43.2,0.058,0.002,0.0059,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-07",24,24,0,,0,0,43.2,0.058,0.002,0.005,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-08",24,23.92,0,,0,0,43.056,0.058,0.002,0.0048,741.428,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-09",24,23.97,0,,0,0,43.146,0.058,0.002,0.0057,742.973,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-10",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-11",24,23.69,0,,0,0,42.582,0.0583,0.005,0.0133,730.182,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-12",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-13",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-14",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-15",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-16",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-17",24,24,0,,0,0,43.2,0.058,0.002,0.0066,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-18",24,23.85,0,,0,0,43.128,0.0583,0.004,0.0098,739.384,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-19",24,24,0,,0,0,43.2,0.058,0.002,0.0057,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-20",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-21",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-22",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-23",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-24",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-25",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-26",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-27",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-28",24,24,0,,0,0,43.2,0.058,0.002,0.006,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-29",24,24,0,,0,0,43.2,0.058,0.002,0.0056,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-09-30",24,24,0,,0,0,43.2,0.058,0.002,0.0059,744,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-01",24,24,0,,0,0,43.2,0.058,0.002,0.0059,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-02",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-03",24,24,0,,0,0,43.2,0.058,0.002,0.0058,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-04",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-05",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-06",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-07",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-08",17,16.87,9.2,,0,0.0001,38.109,0.0582,0.011,0.0162,649.842,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-15",18,17.77,0,,0,0,32.14,0.0581,0.001,0.0046,551.249,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-16",24,24,0,,0,0,43.2,0.058,0.003,0.0093,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-17",24,24,0,,0,0,43.2,0.058,0.003,0.0088,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-18",24,24,0,,0,0,43.2,0.058,0.002,0.0061,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-19",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-20",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-21",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-22",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-23",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-24",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-25",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-26",24,24,0,,0,0,43.2,0.058,0.002,0.0064,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-27",24,24,0,,0,0,43.2,0.058,0.002,0.0067,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-28",24,24,0,,0,0,43.2,0.058,0.002,0.0063,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-29",24,24,0,,0,0,43.2,0.058,0.002,0.006,741.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-30",14,13.18,0,,0,0,23.742,0.0581,0.001,0.0064,407.37,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-10-31",23,22.8,0,,0,0,41.04,0.058,0.002,0.006,704.52,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-01",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-02",24,24,0,,0,0,43.2,0.058,0.002,0.0061,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-03",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-04",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-05",24,24,0,,0,0,43.2,0.058,0.002,0.0062,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-06",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-07",24,24,0,,0,0,43.2,0.058,0.002,0.0063,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-08",24,24,0,,0,0,43.2,0.058,0.003,0.0068,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-09",24,24,0,,0,0,43.2,0.058,0.002,0.0063,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-10",24,24,0,,0,0,43.2,0.058,0.002,0.0065,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-11",24,24,0,,0,0,43.2,0.058,0.003,0.007,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-12",24,24,0,,0,0,43.2,0.058,0.002,0.0065,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-13",24,24,0,,0,0,43.2,0.058,0.002,0.0062,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-14",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-15",24,24,0,,0,0,43.2,0.058,0.002,0.0063,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-16",24,24,0,,0,0,43.2,0.058,0.002,0.0061,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-17",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-18",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-19",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-20",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-21",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-22",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-23",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-24",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-25",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-26",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-27",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-28",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-29",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-11-30",24,24,0,,0,0,43.2,0.058,0.002,0.006,746.4,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-01",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-02",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-03",24,24,0,,0,0,45.6,0.061,0.002,0.0061,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-04",24,24,0,,0,0,45.6,0.061,0.003,0.0067,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-05",24,24,0,,0,0,45.6,0.061,0.002,0.0064,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-06",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-07",24,24,0,,0,0,45.6,0.061,0.002,0.0064,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-08",24,24,0,,0,0,45.6,0.061,0.002,0.0066,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-09",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-10",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-11",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-12",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-13",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-14",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-15",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-16",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-17",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-18",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-19",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-20",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-21",24,24,0,,0,0,45.6,0.061,0.002,0.0063,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-22",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-23",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-24",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-25",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-26",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-27",24,24,0,,0,0,45.6,0.061,0.002,0.006,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-28",24,24,0,,0,0,45.6,0.061,0.003,0.0067,753.6,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-29",24,23.98,188,,0.001,0.0001,165.868,0.0602,0.05,0.0272,2782.168,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-30",24,24,449,,0.001,0.0002,318.9,0.0593,0.105,0.0392,5367.3,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"5",,"2020-12-31",24,24,391,,0.001,0.0007,281.8,0.0592,0.088,0.0373,4743.9,"Pipeline Natural Gas","Other Gas, Residual Oil","Dry bottom wall-fired boiler",,"Other",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-01",1,0.15,0,,0,0.001,0.78,0.059,0,0.061,13.17,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-15",1,0.13,0,,0,0.001,0.65,0.06,0,0.053,10.894,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-19",9,8.36,384.76,,0.001,0.001,214.024,0.0591,0.048,0.0302,3601.364,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-20",9,8.7,369.05,,0.001,0.001,208.455,0.0591,0.049,0.0313,3507.085,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-21",9,8.67,346.43,,0.001,0.001,200.679,0.0591,0.045,0.0293,3378.494,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-01",5,3.7,164.18,,0.001,0.0008,94.684,0.0592,0.034,0.0414,1592.938,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-02",4,3.38,136.68,,0,0.001,79.714,0.059,0.02,0.0343,1341.664,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-03",5,3.34,134.67,,0,0.0008,77.707,0.0596,0.024,0.0386,1306.53,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-04",5,3.74,160.29,,0,0.0006,91.816,0.059,0.035,0.0428,1545.879,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-05",6,4.15,189.15,,0.001,0.0008,105.387,0.059,0.033,0.0343,1774.793,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-06",5,3.75,153.2,,0,0.001,87.107,0.0592,0.026,0.0364,1465.002,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-07",5,3.8,148.26,,0.001,0.001,88.323,0.059,0.02,0.0302,1487.423,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-08",2,1.74,69.03,,0,0.001,39.735,0.059,0.014,0.0465,668.866,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-09",6,4.28,163.45,,0,0.0007,94.807,0.0592,0.024,0.0443,1595.153,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-10",5,3.85,169.22,,0.001,0.001,95.596,0.0592,0.021,0.0264,1609.38,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-11",7,6.09,173.55,,0.001,0.0009,106.856,0.059,0.023,0.0319,1801.462,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-12",5,3.83,154.67,,0,0.001,87.433,0.0594,0.023,0.0308,1469.776,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-13",6,4.84,175.52,,0,0.001,102.108,0.0593,0.024,0.0283,1718.172,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-14",6,4.8,173.2,,0,0.001,101.58,0.0597,0.024,0.0273,1706.56,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-15",5,4.52,177.28,,0,0.001,101.12,0.059,0.025,0.032,1702.488,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-16",5,4.52,174.6,,0,0.001,100.42,0.0592,0.025,0.0332,1690.924,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-17",5,4.83,151.5,,0,0.001,93.097,0.0592,0.02,0.0274,1567.239,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-18",5,4.82,148.78,,0,0.001,90.557,0.059,0.02,0.028,1524.642,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-19",6,4.95,148.52,,0,0.0008,90.876,0.0595,0.02,0.0238,1529.622,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-20",11,9.2,267.43,,0.001,0.0009,166.127,0.0591,0.035,0.0223,2797.505,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-21",6,4.86,166.37,,0,0.001,97.434,0.059,0.021,0.026,1639.561,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-22",7,5.18,166.3,,0.001,0.001,98.876,0.0593,0.02,0.0219,1663.744,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-23",7,5.18,164.1,,0.001,0.001,99.448,0.0593,0.02,0.0214,1673.224,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-24",6,5.08,165.08,,0.001,0.001,97.984,0.0595,0.019,0.0238,1648.076,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-25",10,7.16,265.91,,0.001,0.001,154.5,0.0593,0.03,0.0252,2601.546,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-27",2,0.32,0.32,,0,0.001,1.696,0.06,0.001,0.0725,28.386,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-28",11,9.17,298,,0.001,0.001,179.367,0.0593,0.032,0.0268,3018.811,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-02-29",1,0.1,0,,0,0.001,0.58,0.059,0,0.01,9.79,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-03",1,0.13,0,,0,0.001,0.65,0.059,0,0.054,11.024,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-04",1,0.17,0.17,,0,0.001,0.952,0.06,0.001,0.077,15.98,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-05",6,5,155.6,,0,0.001,95.045,0.0593,0.022,0.0242,1598.905,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-06",6,4.79,169.02,,0,0.0008,98.128,0.0593,0.022,0.0262,1649.642,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-07",6,4.8,177.2,,0,0.001,102.392,0.0592,0.023,0.0268,1724.284,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-08",6,4.78,167.9,,0,0.001,98.474,0.0593,0.023,0.0278,1655.56,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-09",6,4.85,163.74,,0,0.0008,98.148,0.0593,0.022,0.0253,1650.523,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-10",6,4.83,169.74,,0,0.001,99.099,0.0595,0.021,0.0235,1666.227,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-11",5,4.68,178.16,,0,0.001,102.328,0.0598,0.023,0.0306,1719.156,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-25",1,0.2,0,,0,0.001,1.14,0.059,0.001,0.06,19.32,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-08",2,0.17,0,,0,0.001,0.909,0.0595,0.001,0.0375,15.299,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-22",1,0.23,0,,0,0.001,1.219,0.06,0.001,0.099,20.401,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-23",8,6.15,162.1,,0.001,0.001,102.69,0.0594,0.023,0.0265,1725.64,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-24",11,9.73,279.32,,0.001,0.001,172.348,0.0592,0.034,0.0222,2900.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-27",9,7.71,310.64,,0.001,0.0009,178.444,0.0593,0.027,0.0192,3002.131,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-28",10,8.22,301.62,,0.001,0.0008,175.231,0.0596,0.029,0.0196,2947.148,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-29",10,8.78,348.74,,0.001,0.001,198.11,0.0594,0.037,0.0214,3331.446,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-02",12,10.2,270.32,,0.001,0.001,170.732,0.0593,0.03,0.0233,2872.196,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-03",5,3.14,81,,0,0.0008,50.842,0.0596,0.018,0.0284,854.916,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-07",10,8.13,262.36,,0.001,0.0009,156.886,0.0593,0.028,0.0188,2640.704,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-08",7,5.17,171.5,,0.001,0.001,100.72,0.0596,0.02,0.0209,1695.134,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-08",1,0.1,0,,0,0.001,0.79,0.06,0,0.016,13.24,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-18",2,0.38,0,,0,0.001,2.193,0.06,0,0.0265,36.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-24",10,8.34,319.24,,0.001,0.0009,182.534,0.0593,0.033,0.0251,3070.564,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-08",1,0.15,0,,0,0.001,0.885,0.06,0,0.042,14.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-15",5,3.17,80,,0,0.0008,51.116,0.0594,0.013,0.0262,860.086,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-22",6,4.17,107,,0,0.0008,67.766,0.0595,0.02,0.0265,1140.234,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-07-31",10,9.67,418.45,,0.001,0.001,234.174,0.0591,0.043,0.0239,3940.313,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-05",1,0.23,0.46,,0,0.001,1.633,0.06,0.001,0.072,27.37,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-11",1,0.18,0,,0,0.001,1.134,0.059,0.001,0.064,19.134,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-14",10,8.81,368.19,,0.001,0.001,207.021,0.0593,0.045,0.0326,3482.035,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-15",12,9.95,411.46,,0.001,0.001,231.934,0.0592,0.045,0.0223,3905.014,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-16",10,8.89,378.29,,0.001,0.001,211.908,0.0591,0.037,0.0212,3567.333,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-17",10,8.8,381.26,,0.001,0.001,213.231,0.0591,0.037,0.0205,3590.568,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-18",13,11.83,460.98,,0.002,0.001,264.091,0.0591,0.046,0.0206,4445.989,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-19",11,9.83,449,,0.001,0.001,250.066,0.0591,0.044,0.0206,4209.181,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-20",11,9.83,432.88,,0.001,0.001,240.741,0.0592,0.043,0.0212,4051.042,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-21",8,6.83,311,,0.001,0.001,171.341,0.0591,0.033,0.0229,2885.039,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-24",7,5.17,134.4,,0.001,0.0009,84.325,0.0594,0.017,0.0196,1419.69,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-25",12,10.83,407.82,,0.001,0.001,232.87,0.0594,0.039,0.02,3917.877,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-26",13,11.75,484.33,,0.002,0.0009,271.953,0.0595,0.048,0.0213,4573.615,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-27",13,11.78,517,,0.002,0.0008,287.103,0.0593,0.048,0.0208,4829.083,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-28",11,9.77,424.98,,0.001,0.001,237.292,0.0594,0.043,0.0226,3992.919,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-01",1,0.17,0,,0,0,0.799,0.059,0,0.059,13.549,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-04",9,7.13,263.1,,0.001,0.001,154.135,0.0593,0.029,0.0196,2591.83,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-05",12,10.84,479.26,,0.002,0.0009,265.584,0.0593,0.046,0.0205,4469.416,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-06",12,10.9,464.7,,0.001,0.001,260.12,0.0593,0.045,0.0205,4375.32,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-07",11,9.92,433.6,,0.001,0.001,241.004,0.0592,0.043,0.0213,4056.52,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-08",7,5.1,132,,0.001,0.0009,84.197,0.059,0.019,0.0207,1417.587,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-09",4,2.12,53,,0,0.0008,33.654,0.0593,0.014,0.0288,566.494,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-11",3,1.99,83.03,,0,0.001,46.775,0.059,0.019,0.039,786.602,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-21",6,4.21,137.08,,0,0.001,82.136,0.0598,0.019,0.0263,1380.68,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-22",1,0.22,0,,0,0.001,1.122,0.06,0.001,0.072,18.832,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-29",10,8.88,353.66,,0.001,0.001,199.738,0.0594,0.038,0.0235,3360.21,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-09-30",12,10.9,438.42,,0.001,0.001,246.504,0.0593,0.039,0.0187,4144.646,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-01",12,10.88,433.12,,0.001,0.001,244.794,0.0592,0.04,0.0193,4122.068,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-02",10,8.94,361.54,,0.001,0.001,203.516,0.0592,0.035,0.0203,3426.186,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-06",9,7.18,228.56,,0.001,0.001,135.814,0.0592,0.023,0.0201,2285.414,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-14",3,1.13,25.4,,0,0.001,17.174,0.0597,0.008,0.0293,289.56,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-16",7,6.62,264.31,,0.001,0.001,149.968,0.0591,0.028,0.0247,2523.309,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-22",1,0.35,3.5,,0,0.001,3.255,0.059,0.003,0.11,54.88,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-03",2,0.39,6.29,,0,0.0005,4.054,0.059,0.004,0.056,68.464,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-05",9,7.82,235.24,,0.001,0.0009,142.486,0.0593,0.027,0.0204,2396.12,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-06",9,8.08,241.46,,0.001,0.001,146.954,0.0591,0.021,0.0169,2474.952,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-12",2,0.17,0,,0,0,1.712,0.06,0.001,0.046,28.723,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-16",9,7.26,258.14,,0.001,0.001,173.388,0.0593,0.04,0.0306,2916.594,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-18",2,0.23,0,,0,0.001,1.22,0.06,0.001,0.0505,20.417,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Grayson Power Plant",377,"9",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-23",1,0.3,2.7,,0,0.001,7.44,0.06,0.023,0.373,124.95,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-28",5,1.37,11.76,,0,0.001,33.976,0.06,0.106,0.373,570.605,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-30",5,1.21,10.09,,0,0.001,30.008,0.06,0.094,0.373,503.965,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-01-31",1,0.1,1,,0,0.001,2.48,0.06,0.008,0.373,41.65,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-04",12,10.53,609.91,,0.002,0.001,382.746,0.059,0.345,0.1539,6439.911,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-23",19,17.92,1243.73,,0.004,0.001,698.936,0.0591,0.226,0.0566,11762.756,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-24",24,24,1905,,0.005,0.001,1031.5,0.059,0.315,0.0364,17355.3,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-25",24,24,1938,,0.005,0.001,1045.8,0.059,0.29,0.033,17595.5,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-26",24,24,2009,,0.005,0.001,1076.8,0.059,0.266,0.0294,18116.5,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-27",24,24,2017,,0.005,0.001,1080.9,0.059,0.261,0.0288,18192.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-28",24,24,1992,,0.005,0.001,1070.8,0.059,0.258,0.0287,18016.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-29",24,24,1930,,0.005,0.001,1045.2,0.059,0.25,0.0285,17582.5,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-06-30",24,24,1996,,0.005,0.001,1072.4,0.059,0.271,0.03,18042.6,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-01",24,24,2026,,0.005,0.001,1083.2,0.059,0.272,0.0299,18225.4,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-02",24,24,2061,,0.006,0.001,1100.9,0.059,0.285,0.0308,18523.6,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-03",24,24,2072,,0.006,0.001,1103.5,0.059,0.284,0.0306,18569.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-04",24,24,2080,,0.006,0.001,1109.3,0.059,0.286,0.0307,18666.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-05",24,24,1957,,0.005,0.001,1054.8,0.059,0.275,0.031,17749,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-06",24,24,1911,,0.005,0.001,1033.5,0.059,0.273,0.0314,17388.3,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-07",24,24,2087,,0.006,0.001,1108.3,0.059,0.293,0.0315,18651.1,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-08",24,24,2186,,0.006,0.001,1154.6,0.059,0.302,0.0311,19431.3,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-09",24,24,1911,,0.005,0.001,1034.2,0.059,0.275,0.0316,17400.2,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-10",24,24,1848,,0.005,0.001,1010.9,0.059,0.272,0.032,17009,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-11",24,24,1880,,0.005,0.001,1022.1,0.059,0.276,0.0322,17195.4,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-12",24,24,1844,,0.005,0.001,1005.5,0.059,0.269,0.0318,16924.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-13",24,24,1868,,0.005,0.001,1014.7,0.059,0.273,0.032,17076.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-14",24,24,1908,,0.005,0.001,1032.1,0.059,0.276,0.0318,17368.1,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-15",24,24,1924,,0.005,0.001,1038.7,0.059,0.282,0.0323,17479.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-16",24,24,1944,,0.005,0.001,1049.4,0.059,0.278,0.0315,17658.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-17",24,24,1940,,0.005,0.001,1044.2,0.059,0.277,0.0316,17574.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-18",24,24,1999,,0.005,0.001,1072.1,0.059,0.283,0.0314,18045.1,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-19",24,24,1992,,0.005,0.001,1070.8,0.059,0.282,0.0314,18020.1,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-20",14,13.62,1064.98,,0.003,0.001,579.542,0.059,0.155,0.0317,9753.298,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-28",17,16.6,1123.6,,0.003,0.001,634.08,0.0591,0.174,0.0369,10668.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-29",24,24,2131,,0.006,0.001,1133.9,0.059,0.289,0.0303,19081.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-30",24,24,2126,,0.006,0.001,1131,0.059,0.299,0.0314,19030,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-07-31",24,24,2235,,0.006,0.001,1178.9,0.059,0.316,0.0319,19840.4,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-01",24,24,2076,,0.006,0.001,1109.2,0.059,0.301,0.0323,18663.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-02",24,24,2005,,0.005,0.001,1077.6,0.059,0.295,0.0325,18130.6,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-03",24,24,2091,,0.006,0.001,1112.2,0.059,0.303,0.0324,18713.8,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-04",24,24,2134,,0.006,0.001,1132.6,0.059,0.306,0.0321,19056.3,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-05",24,24,1969,,0.005,0.001,1062.9,0.059,0.293,0.0328,17885.3,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-06",24,24,1978,,0.005,0.001,1067.1,0.059,0.29,0.0324,17954.2,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-07",24,24,1896,,0.005,0.001,1033.1,0.059,0.281,0.0323,17388,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-08",24,24,2057,,0.006,0.001,1099.4,0.059,0.292,0.0316,18497.8,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-09",24,24,1990,,0.005,0.001,1068.7,0.059,0.283,0.0315,17985.1,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-10",24,24,1995,,0.005,0.001,1070.4,0.059,0.289,0.0322,18007.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-11",24,24,2118,,0.006,0.001,1124.1,0.059,0.296,0.0313,18913.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-12",24,24,2120,,0.006,0.001,1128.8,0.059,0.297,0.0313,18993.1,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-13",24,24,2121,,0.006,0.001,1124.7,0.059,0.297,0.0314,18925.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-14",24,24,2187,,0.006,0.001,1157.3,0.059,0.304,0.0313,19471.1,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-15",24,24,2118,,0.006,0.001,1127.2,0.059,0.29,0.0306,18967.8,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-16",24,24,2105,,0.006,0.001,1119,0.059,0.287,0.0305,18827.1,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-17",24,24,2018,,0.005,0.001,1082.6,0.059,0.278,0.0305,18217.4,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-18",24,24,2036,,0.005,0.001,1089.4,0.059,0.281,0.0308,18327.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-19",24,24,2044,,0.006,0.001,1094.7,0.059,0.282,0.0307,18420.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-20",24,24,2040,,0.006,0.001,1091.5,0.059,0.286,0.0311,18367.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-21",24,24,2048,,0.006,0.001,1096.4,0.059,0.302,0.0328,18449.2,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-22",1,0.22,9.24,,0,0.001,6.314,0.059,0.002,0.039,106.392,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-23",6,5.05,314.5,,0.001,0.001,181.475,0.0592,0.067,0.061,3052.415,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-24",24,24,2083,,0.006,0.001,1111.5,0.059,0.278,0.0299,18708.2,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-25",24,24,2243,,0.006,0.001,1178.6,0.059,0.258,0.026,19833.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-26",24,24,2154,,0.006,0.001,1139.7,0.059,0.267,0.0279,19179.4,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-27",24,24,2299,,0.006,0.001,1203.5,0.059,0.288,0.0285,20250.4,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-28",24,24,2237,,0.006,0.001,1175.8,0.059,0.281,0.0285,19783.6,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-29",24,24,2216,,0.006,0.001,1168.5,0.059,0.277,0.0282,19664.3,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-30",24,24,2130,,0.006,0.001,1129.9,0.059,0.268,0.0283,19013.5,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-08-31",24,24,2193,,0.006,0.001,1158,0.059,0.266,0.0274,19490.8,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-01",24,24,1911,,0.005,0.001,1039.5,0.059,0.265,0.0303,17491.3,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-02",24,24,1994,,0.005,0.001,1076.8,0.059,0.261,0.0288,18120.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-03",24,24,1962,,0.005,0.001,1064.8,0.059,0.259,0.029,17915.8,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-04",24,24,1971,,0.005,0.001,1065.1,0.059,0.261,0.0291,17921.3,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-05",24,24,1974,,0.005,0.001,1067.4,0.059,0.261,0.0291,17961.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-06",24,24,1926,,0.005,0.001,1047.7,0.059,0.258,0.0293,17629.7,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-07",24,24,1854,,0.005,0.001,1010.9,0.059,0.251,0.0295,17010.6,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-08",24,24,1822,,0.005,0.001,997.8,0.059,0.254,0.0303,16791.9,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-09",24,24,1792,,0.005,0.001,984.9,0.059,0.263,0.0318,16573.6,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-10",24,23.77,1792.82,,0.005,0.001,984.906,0.059,0.266,0.0321,16574.889,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"2-2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-07",18,17.92,633.04,,0.002,0.001,340.2,0.0593,1.657,0.5799,5724.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-08",24,24,1161,,0.003,0.001,538.5,0.0592,0.024,0.0053,9065.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-09",24,24,1195,,0.003,0.001,549.4,0.0593,0.024,0.0053,9243.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-10",24,24,1134,,0.003,0.001,527.3,0.0592,0.023,0.0052,8872.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-11",24,24,1087,,0.003,0.001,509.7,0.0593,0.022,0.0052,8576.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-12",24,24,1104,,0.003,0.001,515.9,0.0592,0.022,0.0051,8682.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-13",24,24,1092,,0.003,0.001,514,0.0594,0.023,0.0053,8645.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-14",24,24,1101,,0.003,0.001,516.1,0.0592,0.023,0.0052,8687.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-15",24,24,1097,,0.003,0.001,515.4,0.0593,0.022,0.0051,8668.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-16",24,24,1093,,0.003,0.001,512.9,0.0595,0.022,0.0052,8624.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-17",24,24,1102,,0.003,0.001,515.7,0.0591,0.022,0.0051,8679.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-18",24,24,1096,,0.003,0.001,513.6,0.0593,0.022,0.005,8644.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-19",24,24,1095,,0.003,0.001,513.7,0.0593,0.021,0.0049,8644.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-20",24,24,1066,,0.003,0.001,502.2,0.0595,0.022,0.0051,8446.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-21",24,24,1072,,0.003,0.001,507.1,0.0593,0.325,0.0764,8532.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-22",24,24,1118,,0.003,0.001,521.9,0.0592,0.918,0.2189,8782.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-23",24,24,1086,,0.003,0.001,508.7,0.0592,0.022,0.005,8563.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-24",24,24,1102,,0.003,0.001,513.2,0.0592,0.022,0.005,8634.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-25",24,24,1066,,0.003,0.001,501.8,0.0593,0.021,0.005,8443.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-26",24,24,1105,,0.003,0.001,516.8,0.0594,0.021,0.0049,8690.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-27",24,24,1016,,0.002,0.001,487.5,0.0594,0.021,0.005,8201.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-28",24,24,1028,,0.002,0.001,493.7,0.0593,0.022,0.0053,8306.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-29",24,24,1084,,0.003,0.001,515.7,0.0593,0.022,0.005,8678.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-30",24,24,1075,,0.003,0.001,510.3,0.0593,0.022,0.0052,8584.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-01-31",24,24,1087,,0.003,0.001,515.3,0.0593,0.022,0.005,8667.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-01",24,24,1078,,0.003,0.001,511.1,0.0592,0.022,0.0051,8602.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-02",24,24,1024,,0.002,0.001,490.2,0.0593,0.022,0.0053,8248.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-03",24,24,1120,,0.003,0.001,526.5,0.0591,0.323,0.0765,8860.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-04",24,24,1094,,0.003,0.001,519.8,0.0593,0.023,0.0052,8743.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-05",24,24,1146,,0.003,0.001,539.4,0.0591,0.023,0.0051,9079.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-06",24,24,1072,,0.003,0.001,511.1,0.0593,0.022,0.0052,8597.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-07",24,24,1125,,0.003,0.001,530.9,0.0593,0.023,0.0052,8935.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-08",1,0.2,3.8,,0,0.001,3.14,0.06,0,0.008,52.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-11",15,13.75,538.2,,0.001,0.001,277.395,0.0595,0.017,0.0142,4664.355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-12",24,24,1049,,0.003,0.001,495.9,0.0593,0.022,0.0052,8345.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-13",24,24,1135,,0.003,0.001,528.5,0.0593,0.023,0.0053,8892.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-14",24,24,1069,,0.003,0.001,505.9,0.0593,0.022,0.0051,8510.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-15",24,24,1073,,0.003,0.001,505,0.0593,0.021,0.005,8496.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-16",24,24,1041,,0.002,0.001,494.1,0.0593,0.022,0.0053,8312.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-17",24,24,1047,,0.002,0.001,493.8,0.0593,0.021,0.0051,8305.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-18",24,24,1086,,0.003,0.001,508.7,0.0593,0.021,0.005,8557.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-19",24,24,1053,,0.002,0.001,492.7,0.0593,0.021,0.0051,8291.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-20",24,24,1092,,0.003,0.001,508.7,0.0593,0.021,0.0049,8561,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-21",24,24,1130,,0.003,0.001,523.3,0.0593,0.022,0.0051,8806.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-22",24,24,1154,,0.003,0.001,533.3,0.0592,0.022,0.005,8974.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-23",24,24,1101,,0.003,0.001,514.8,0.0592,0.023,0.0052,8662.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-24",24,24,1121,,0.003,0.001,520.4,0.0594,0.023,0.0052,8754.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-25",24,24,1066,,0.003,0.001,501.2,0.0593,0.021,0.005,8430.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-26",24,24,1113,,0.003,0.001,519.5,0.0592,0.023,0.0052,8740.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-27",24,24,1165,,0.003,0.001,537.6,0.0593,0.023,0.005,9044.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-28",24,24,1112,,0.003,0.001,517.2,0.0593,0.021,0.0049,8700.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-02-29",24,24,1081,,0.003,0.001,506.9,0.0594,0.021,0.005,8527.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-01",24,24,1136,,0.003,0.001,525.2,0.0595,0.022,0.005,8829.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-02",23,22.32,1058.68,,0.002,0.001,491.956,0.0594,0.022,0.0053,8275.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-26",14,10.98,305.32,,0.001,0.001,206.143,0.0591,0.016,0.0281,3469.727,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-27",1,0.63,21.42,,0,0.001,13.923,0.059,0.001,0.007,234.171,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-28",9,8.07,271.6,,0.001,0.001,177.483,0.0594,0.012,0.0183,2986.459,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-29",8,6.83,221.12,,0.001,0.001,147.095,0.0596,0.011,0.0138,2473.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-30",9,7.42,228.33,,0.001,0.001,153.367,0.0593,0.02,0.0454,2579.852,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-05-31",7,6.88,222.32,,0.001,0.001,146.7,0.0593,0.015,0.019,2468.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-01",24,24,1286,,0.003,0.001,583.5,0.0592,0.024,0.0049,9822.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-02",22,21.68,1009.99,,0.002,0.001,477.197,0.0593,1.325,0.3163,8029.636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-03",24,24,1346,,0.003,0.001,599.8,0.0592,0.025,0.005,10090.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-04",24,24,1322,,0.003,0.001,590.3,0.0591,0.393,0.0762,9936.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-05",24,24,1285,,0.003,0.001,576.3,0.0593,0.023,0.0047,9698.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-06",24,24,1208,,0.003,0.001,553.1,0.0592,0.024,0.0051,9308.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-07",24,24,1264,,0.003,0.001,574,0.0595,0.022,0.0047,9651.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-08",24,24,1197,,0.003,0.001,545.4,0.0592,0.023,0.0051,9177.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-09",24,24,1206,,0.003,0.001,553.9,0.0593,0.023,0.0048,9319.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-10",24,24,1085,,0.002,0.001,491.3,0.0594,0.021,0.0051,8266.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-11",24,24,1112,,0.003,0.001,502.2,0.0595,0.021,0.0051,8443.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-12",23,23,1138,,0.003,0.001,507.5,0.0593,0.022,0.0053,8539.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-15",11,10.57,467.84,,0.001,0.001,216.914,0.0591,0.014,0.0129,3650.783,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-16",24,24,1151,,0.003,0.001,518.6,0.0592,0.022,0.005,8727.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-17",24,24,1171,,0.003,0.001,527.4,0.0593,0.022,0.005,8872.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-18",24,24,1248,,0.003,0.001,554.6,0.0593,0.024,0.0051,9329.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-19",24,24,1194,,0.003,0.001,534.2,0.0591,0.023,0.0051,8992.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-20",24,24,1268,,0.003,0.001,560.8,0.0591,0.024,0.005,9437.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-21",24,24,1220,,0.003,0.001,542,0.0593,0.023,0.005,9120.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-22",24,24,1201,,0.003,0.001,535.3,0.0592,0.023,0.005,9007.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-23",24,24,1247,,0.003,0.001,553.1,0.0593,0.023,0.005,9305.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-24",24,24,1222,,0.003,0.001,543.8,0.0593,0.023,0.005,9146.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-25",24,24,1200,,0.003,0.001,535.3,0.0593,1.005,0.2188,9009,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-26",24,24,1340,,0.003,0.001,584.7,0.0592,0.025,0.005,9841.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-27",24,23.28,1302.84,,0.003,0.001,570.468,0.0593,0.024,0.0051,9595.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-07",10,9.03,344,,0.001,0.0009,164.93,0.0591,0.012,0.0092,2776.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-08",24,24,1124,,0.003,0.001,506.9,0.0593,0.022,0.0053,8527.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-09",24,24,1282,,0.003,0.001,562.2,0.0594,0.024,0.0052,9453.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-10",24,24,1264,,0.003,0.001,555.9,0.0591,0.023,0.005,9358,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-11",24,24,1259,,0.003,0.001,553.1,0.0594,0.023,0.0049,9304.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-12",24,24,1218,,0.003,0.001,539,0.0593,0.022,0.0049,9065.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-13",24,24,1239,,0.003,0.001,544.2,0.0592,0.023,0.0049,9160.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-14",24,24,1259,,0.003,0.001,552.9,0.0594,0.025,0.0053,9300.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-15",24,24,1259,,0.003,0.001,552.4,0.0592,0.025,0.0055,9296.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-16",24,24,1311,,0.003,0.001,573.5,0.059,0.026,0.0053,9653.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-17",24,24,1376,,0.003,0.001,609.9,0.0592,0.026,0.0051,10262.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-18",24,24,1407,,0.003,0.001,622.1,0.0592,0.028,0.0053,10465.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-19",24,24,1363,,0.003,0.001,605.3,0.0592,0.027,0.0054,10188.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-20",24,24,1328,,0.003,0.001,595.7,0.0593,0.025,0.0049,10019.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-21",24,24,1318,,0.003,0.001,577.1,0.0593,0.025,0.0052,9707.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-22",24,24,1337,,0.003,0.001,590.9,0.0592,0.025,0.0051,9941.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-23",24,24,1346,,0.003,0.001,599,0.0593,0.026,0.005,10079.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-24",24,24,1324,,0.003,0.001,589.2,0.059,0.026,0.0053,9920.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-25",24,24,1357,,0.003,0.001,589.1,0.0592,0.027,0.0054,9913.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-26",24,24,1325,,0.003,0.001,577.8,0.0592,0.026,0.0053,9724.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-27",24,24,1321,,0.003,0.001,578.8,0.0592,0.026,0.0054,9739.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-28",24,24,1263,,0.003,0.001,557,0.0592,0.025,0.0053,9374.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-29",24,24,1350,,0.003,0.001,588.8,0.0592,0.026,0.0052,9911.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-30",24,24,1330,,0.003,0.001,581.8,0.0593,0.026,0.0053,9788.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-07-31",24,24,1373,,0.003,0.001,596.6,0.0591,0.027,0.0053,10044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-01",24,24,1333,,0.003,0.001,583.6,0.0592,0.026,0.0054,9822.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-02",24,24,1270,,0.003,0.001,558.7,0.0591,0.024,0.0051,9402.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-03",24,24,1324,,0.003,0.001,577.9,0.0593,0.026,0.0054,9726.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-04",24,24,1375,,0.003,0.001,598.6,0.0593,0.026,0.0051,10070.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-05",24,24,1216,,0.003,0.001,539.2,0.0592,0.024,0.0053,9069.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-06",24,24,1201,,0.003,0.001,534,0.059,0.024,0.0052,8990.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-07",24,24,1194,,0.003,0.001,533.8,0.0593,0.023,0.0051,8978.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-08",24,24,1331,,0.003,0.001,580.8,0.0592,0.027,0.0055,9772.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-09",24,24,1351,,0.003,0.001,584.7,0.0592,0.026,0.0052,9839.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-10",24,24,1292,,0.003,0.001,565,0.0593,0.025,0.0053,9505.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-11",24,24,1295,,0.003,0.001,569.8,0.0592,0.024,0.005,9587.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-12",24,24,1293,,0.003,0.001,567.5,0.0593,0.025,0.0053,9551.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-13",24,24,1318,,0.003,0.001,573.1,0.0592,0.025,0.0052,9645.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-14",24,24,1323,,0.003,0.001,576.5,0.0593,0.026,0.0055,9700.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-15",24,24,1340,,0.003,0.001,586,0.0593,0.025,0.0051,9858.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-16",24,24,1292,,0.003,0.001,566.1,0.0591,0.025,0.0052,9526.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-17",24,24,1317,,0.003,0.001,574.7,0.0592,0.025,0.0053,9669.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-18",24,24,1290,,0.003,0.001,566.8,0.0592,0.025,0.0052,9535.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-19",24,24,1276,,0.003,0.001,562.1,0.0591,0.024,0.0051,9464.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-20",24,24,1345,,0.003,0.001,588.8,0.0592,0.026,0.0053,9904.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-21",21,19.61,1059.26,,0.002,0.001,470.096,0.0591,0.025,0.0065,7910.828,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-22",24,24,1323,,0.003,0.001,580.6,0.0594,0.026,0.0053,9765.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-23",24,24,1309,,0.003,0.001,573.4,0.0594,0.026,0.0054,9643.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-24",24,24,1364,,0.003,0.001,595.8,0.0592,0.028,0.0055,10029.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-25",24,24,1369,,0.003,0.001,596.3,0.059,0.028,0.0056,10036.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-26",24,24,1367,,0.003,0.001,596.8,0.0592,0.027,0.0054,10042.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-27",24,24,1368,,0.003,0.001,597.2,0.0591,0.027,0.0055,10050.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-28",23,22.83,1300.82,,0.003,0.001,568.084,0.0592,0.027,0.0057,9559.776,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-02",13,12.97,676.28,,0.002,0.001,305.644,0.0593,0.018,0.008,5137.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-03",24,24,1291,,0.003,0.001,572.5,0.0592,0.023,0.0047,9632.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-04",16,14.94,697.52,,0.002,0.001,321.78,0.0592,0.021,0.0166,5415.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-05",24,24,1183,,0.003,0.001,533,0.0591,0.022,0.0049,8973.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-06",24,24,1155,,0.003,0.001,520.6,0.0593,0.022,0.005,8758.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-07",24,24,1265,,0.003,0.001,562,0.0592,0.024,0.005,9457.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-08",24,24,1167,,0.003,0.001,525.1,0.0592,0.023,0.0052,8836.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-09",24,24,1136,,0.003,0.001,513.9,0.0593,0.022,0.0051,8646.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-10",24,24,1156,,0.003,0.001,521.4,0.0592,0.023,0.0052,8775.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-11",24,24,1063,,0.002,0.001,484.6,0.0592,0.021,0.0052,8155.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-12",24,24,1131,,0.003,0.001,508.2,0.0593,0.022,0.0052,8551.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-13",24,24,1116,,0.003,0.001,503.4,0.0592,0.021,0.0049,8474.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-14",24,24,1264,,0.003,0.001,557.2,0.0592,0.024,0.0052,9378.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-15",24,24,1222,,0.003,0.001,542.4,0.0593,0.025,0.0055,9127,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-16",24,24,1251,,0.003,0.001,552.8,0.0593,0.024,0.0052,9299.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-17",24,24,1222,,0.003,0.001,541.3,0.0593,0.024,0.0052,9110.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-18",24,24,1180,,0.003,0.001,525.6,0.0593,0.022,0.0051,8839.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-19",24,24,1163,,0.003,0.001,518.9,0.0593,0.022,0.0051,8732.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-20",24,24,1138,,0.003,0.001,510.9,0.0593,0.022,0.0051,8599.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-21",24,24,1243,,0.003,0.001,550.7,0.0593,0.023,0.005,9265,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-22",24,24,1445,,0.003,0.001,632.1,0.0591,0.028,0.0052,10637.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-23",24,24,1371,,0.003,0.001,608.2,0.0592,0.027,0.0053,10232.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-24",24,24,1465,,0.003,0.001,640,0.0592,0.03,0.0055,10769.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-25",24,24,1262,,0.003,0.001,557,0.0592,0.024,0.0052,9372.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-26",24,24,1148,,0.003,0.001,513.8,0.0593,0.023,0.0052,8643.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-27",24,24,1174,,0.003,0.001,522.9,0.0592,0.023,0.0053,8800.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-28",24,24,1100,,0.003,0.001,498.3,0.0594,0.022,0.0052,8381.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-29",24,24,1173,,0.003,0.001,524.6,0.0593,0.024,0.0054,8824.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-09-30",24,24,982,,0.002,0.001,453.8,0.0592,0.02,0.0053,7637,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-01",24,24,1093,,0.002,0.001,494.6,0.0593,0.022,0.0054,8322.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-02",24,24,1095,,0.003,0.001,495.8,0.0593,0.021,0.0051,8343.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-03",24,24,1137,,0.003,0.001,510.8,0.0595,0.023,0.0053,8589.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-04",24,24,1241,,0.003,0.001,545.3,0.0593,0.024,0.0053,9175.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-05",24,24,1191,,0.003,0.001,527.8,0.0592,0.024,0.0053,8882.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-06",24,24,1142,,0.003,0.001,510.6,0.0591,0.022,0.0052,8597.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-07",24,24,1219,,0.003,0.001,540.8,0.0592,0.023,0.0051,9097.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-08",24,24,1290,,0.003,0.001,566.7,0.0593,0.024,0.0051,9532.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-09",24,23.3,1121.7,,0.003,0.001,503.44,0.0593,0.023,0.0055,8470,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-12",12,11.67,535.38,,0.001,0.001,245.403,0.0591,0.014,0.0103,4130.247,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-13",24,24,1214,,0.003,0.001,538.7,0.0594,0.023,0.0052,9062.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-14",24,24,1250,,0.003,0.001,551.4,0.0592,0.024,0.0051,9281.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-15",24,24,1162,,0.003,0.001,521.2,0.0593,0.023,0.0052,8766.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-16",24,24,1202,,0.003,0.001,534.5,0.0593,0.023,0.0051,8993,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-17",24,24,1173,,0.003,0.001,524.4,0.0593,0.023,0.0052,8823.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-18",24,24,1129,,0.003,0.001,507.2,0.0593,0.022,0.0051,8533.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-19",24,24,1108,,0.003,0.001,499.9,0.0593,0.023,0.0054,8414.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-20",24,24,1279,,0.003,0.001,562.7,0.0591,0.025,0.0053,9472.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-21",24,24,1172,,0.003,0.001,522.5,0.0593,0.022,0.005,8791,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-22",24,24,1164,,0.003,0.001,525.4,0.0592,0.021,0.0048,8845.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-23",24,24,1339,,0.003,0.001,597.4,0.0591,0.024,0.0048,10055.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-24",24,24,1410,,0.003,0.001,626,0.0594,0.027,0.005,10529.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-25",24,24,1379,,0.003,0.001,614.7,0.0592,0.027,0.0052,10345.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-26",24,24,1240,,0.003,0.001,566.9,0.0591,0.026,0.0054,9542.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-27",24,24,1238,,0.003,0.001,562.4,0.0591,0.027,0.0056,9463.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-28",24,24,1354,,0.003,0.001,607.2,0.0592,0.027,0.0053,10215.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-29",24,24,1376,,0.003,0.001,612.1,0.0591,0.029,0.0056,10301.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-30",24,24,1373,,0.003,0.001,611.9,0.0591,0.028,0.0055,10297.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-10-31",24,24,1405,,0.003,0.001,621.7,0.0591,0.028,0.0053,10463.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-01",24,24,1422,,0.003,0.001,628.6,0.0592,0.028,0.0053,10574.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-02",24,24,1261,,0.003,0.001,563.6,0.0593,0.024,0.0051,9481.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-03",24,24,1200,,0.003,0.001,532.6,0.0594,0.023,0.0052,8961.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-04",24,24,1006,,0.002,0.001,463.3,0.0593,0.02,0.0051,7797.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-05",24,24,1019,,0.002,0.001,467.3,0.0592,0.021,0.0053,7865.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-06",24,24,1188,,0.003,0.001,529.6,0.0592,0.023,0.0051,8913.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-07",4,3.35,128.75,,0,0.001,62.075,0.0593,0.003,0.0055,1044.215,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-13",10,9.49,262.75,,0.001,0.001,172.811,0.0594,0.016,0.0151,2906.895,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-14",24,24,1361,,0.003,0.001,606.2,0.0593,0.028,0.0055,10202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-15",24,24,963,,0.002,0.001,462.8,0.0591,0.021,0.0054,7793.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-16",24,24,968,,0.002,0.001,465.9,0.0592,0.021,0.0053,7840.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-17",24,24,1356,,0.003,0.001,603.3,0.0591,0.027,0.0053,10153.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-18",24,24,1284,,0.003,0.001,579.2,0.0593,0.025,0.0051,9745.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-19",24,24,1172,,0.003,0.001,537.5,0.0593,0.023,0.0052,9046.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-20",24,24,1248,,0.003,0.001,565,0.0591,0.025,0.0052,9507.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-21",24,24,1248,,0.003,0.001,564.2,0.0593,0.025,0.0051,9491.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-22",24,24,1298,,0.003,0.001,583.4,0.0591,0.026,0.0052,9817.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-23",24,24,1353,,0.003,0.001,604.2,0.0594,0.026,0.0052,10162.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-24",24,24,1415,,0.003,0.001,627.7,0.0592,0.03,0.0056,10562.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-25",24,24,1412,,0.003,0.001,627,0.0592,0.03,0.0058,10551.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-26",24,24,1395,,0.003,0.001,620.7,0.0594,0.03,0.0056,10442,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-27",24,24,1385,,0.003,0.001,616.6,0.0591,0.03,0.0058,10376,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-28",24,24,1341,,0.003,0.001,601.4,0.0592,0.029,0.0058,10117.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-29",24,24,1347,,0.003,0.001,602,0.0591,0.029,0.0056,10130.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-11-30",24,24,1249,,0.003,0.001,566.2,0.0592,0.026,0.0054,9526.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-01",24,24,1048,,0.002,0.001,494.7,0.0594,0.023,0.0055,8321.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-02",1,0.52,18.72,,0,0.001,9.828,0.059,0,0.005,165.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-07",2,1.63,37.56,,0,0.001,24.211,0.059,0.01,0.076,407.905,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-08",24,24,1089,,0.003,0.001,507.8,0.0594,0.019,0.0045,8541.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-09",24,24,1076,,0.003,0.001,503.7,0.0593,0.022,0.0051,8474.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-10",24,24,1077,,0.003,0.001,506.1,0.0591,1.171,0.29,8521.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-11",7,6.68,298.72,,0.001,0.001,140.46,0.0591,0.006,0.0053,2363.532,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-08",9,7.45,169.89,,0.001,0.001,131.828,0.0596,0.019,0.0403,2215.987,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-22",15,14.6,416.4,,0.001,0.001,274.08,0.0594,0.021,0.0139,4610.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-23",24,24,1172,,0.003,0.001,536.6,0.0593,0.02,0.0044,9030.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-24",24,24,1270,,0.003,0.001,573.8,0.0592,0.021,0.0043,9652.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-25",24,24,1211,,0.003,0.001,552.2,0.0592,0.02,0.0042,9292.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-26",24,24,1329,,0.003,0.001,596.5,0.0593,0.024,0.0048,10036.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-27",24,24,1318,,0.003,0.001,590.6,0.0592,0.023,0.0046,9938.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-28",24,24,1270,,0.003,0.001,572.9,0.0592,0.02,0.004,9643.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-29",24,24,1281,,0.003,0.001,577,0.0591,0.022,0.0046,9712.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-04-30",24,24,1343,,0.003,0.001,601.5,0.0592,0.023,0.0045,10123,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-01",24,24,1246,,0.003,0.001,545.7,0.0591,0.02,0.0044,9189.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-02",24,24,1288,,0.003,0.001,563.2,0.0592,0.021,0.0044,9478.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-03",24,24,1242,,0.003,0.001,546.3,0.0591,0.02,0.0043,9195.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-04",24,24,1175,,0.003,0.001,521.4,0.0592,1.245,0.2896,8771.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-05",24,24,1235,,0.003,0.001,543.7,0.0593,0.019,0.0041,9149.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-06",24,24,1245,,0.003,0.001,543.7,0.0592,0.02,0.0045,9151.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-07",24,24,1230,,0.003,0.001,541.7,0.0593,0.019,0.004,9117.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-08",24,24,1180,,0.003,0.001,521.2,0.0593,0.018,0.004,8766.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-09",24,24,1231,,0.003,0.001,539.2,0.0593,0.021,0.0046,9073,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-10",24,24,1386,,0.003,0.001,590.7,0.0592,0.025,0.005,9943.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-11",24,24,1237,,0.003,0.001,541.5,0.0593,0.02,0.0043,9111.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-12",24,24,1349,,0.003,0.001,582.1,0.0592,0.023,0.0046,9794.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-13",24,24,1238,,0.003,0.001,545.8,0.0591,0.02,0.0043,9185.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-14",24,24,1303,,0.003,0.001,567.8,0.0593,0.022,0.0045,9550.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-15",24,24,1301,,0.003,0.001,565,0.0593,0.022,0.0046,9508,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-16",24,24,1234,,0.003,0.001,540.1,0.0592,0.329,0.0755,9089.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-17",24,24,1311,,0.003,0.001,569.9,0.0592,0.022,0.0045,9591.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-18",24,24,1196,,0.003,0.001,527.8,0.0593,0.019,0.0043,8882,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-19",24,24,1181,,0.003,0.001,526.1,0.0594,0.021,0.0048,8846.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-20",24,24,1364,,0.003,0.001,589.5,0.0591,0.025,0.005,9919.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-21",24,24,1385,,0.003,0.001,597.6,0.0592,0.025,0.0049,10053.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-22",24,24,1358,,0.003,0.001,588.4,0.0591,0.024,0.0048,9902.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-23",24,24,1291,,0.003,0.001,563.2,0.0593,0.022,0.0046,9476.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-24",24,24,1302,,0.003,0.001,569.8,0.0594,0.022,0.0046,9583.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-25",24,24,1328,,0.003,0.001,583.9,0.0592,0.024,0.0049,9825.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-26",14,13.02,635.42,,0.001,0.001,285.438,0.0592,0.01,0.0041,4803.494,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-29",2,1.18,1.65,,0,0.001,8.573,0.0595,0.007,0.0995,144.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-09",4,3.8,126,,0,0.001,64.6,0.0593,0.398,0.8593,1086.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-10",24,24,1079,,0.002,0.001,488.3,0.0593,0.019,0.0047,8216.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-11",24,24,1110,,0.003,0.001,498.8,0.0592,0.019,0.0045,8394.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-12",24,24,1180,,0.003,0.001,525.4,0.0593,0.022,0.0049,8840,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-13",24,24,1322,,0.003,0.001,594.9,0.0592,0.023,0.0045,10011.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-14",24,24,1337,,0.003,0.001,598.7,0.0592,0.023,0.0045,10077.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-15",24,24,1198,,0.003,0.001,546.4,0.0593,0.021,0.0045,9190.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-16",24,24,1144,,0.003,0.001,515.5,0.0593,0.02,0.0046,8672.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-17",24,24,1166,,0.003,0.001,524.2,0.0592,0.934,0.2188,8821.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-18",24,24,1254,,0.003,0.001,554.4,0.0592,0.333,0.076,9330.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-19",24,24,1188,,0.003,0.001,531.5,0.0592,0.02,0.0044,8944.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-20",24,24,1263,,0.003,0.001,557.5,0.0592,0.022,0.0048,9384.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-21",24,24,1214,,0.003,0.001,538.5,0.0591,0.021,0.0046,9063.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-22",24,24,1195,,0.003,0.001,532.3,0.0593,0.019,0.0043,8956.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-23",24,24,1242,,0.003,0.001,550,0.0593,0.021,0.0045,9255.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-24",24,24,1219,,0.003,0.001,540.5,0.0591,0.021,0.0047,9097.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-25",24,24,1197,,0.003,0.001,532.3,0.0594,0.021,0.0047,8954.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-26",24,24,1332,,0.003,0.001,582.1,0.0593,0.024,0.0048,9791.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-27",24,24,1344,,0.003,0.001,586.5,0.0592,0.025,0.005,9864.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-28",24,24,1376,,0.003,0.001,609.4,0.0591,0.027,0.0052,10260.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-29",24,24,1315,,0.003,0.001,588.5,0.0592,0.024,0.0048,9901.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-06-30",24,24,1351,,0.003,0.001,604.4,0.0591,0.025,0.005,10170.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-01",24,24,1379,,0.003,0.001,613.4,0.0592,0.027,0.0053,10320.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-02",24,24,1336,,0.003,0.001,599.3,0.0592,0.025,0.0048,10084.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-03",24,24,1363,,0.003,0.001,608.3,0.0593,0.026,0.0051,10234.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-04",24,24,1360,,0.003,0.001,605.2,0.0591,0.026,0.0052,10186.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-05",24,24,1318,,0.003,0.001,588.8,0.0592,0.024,0.0049,9907.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-06",24,24,1242,,0.003,0.001,560.3,0.0593,0.021,0.0043,9427.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-07",24,24,1194,,0.003,0.001,542.4,0.059,0.021,0.0045,9128.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-08",24,24,1118,,0.003,0.001,504.7,0.0593,0.022,0.0051,8490.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-09",24,24,1274,,0.003,0.001,559.2,0.0593,0.023,0.005,9410.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-10",24,24,1259,,0.003,0.001,553.9,0.0592,0.021,0.0045,9320.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-11",24,24,1246,,0.003,0.001,550.2,0.0592,0.022,0.0046,9258.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-12",24,24,1207,,0.003,0.001,534.9,0.0591,0.02,0.0045,9001.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-13",24,24,1227,,0.003,0.001,540.7,0.0593,0.021,0.0045,9096.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-14",24,24,1251,,0.003,0.001,550.2,0.0593,0.023,0.005,9257.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-15",24,24,1252,,0.003,0.001,550.1,0.0592,0.024,0.005,9257.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-16",24,24,1299,,0.003,0.001,570.3,0.0591,0.024,0.0049,9598.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-17",1,0.38,11.78,,0,0.001,6.992,0.059,0,0.005,117.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-20",7,6.63,293.19,,0.001,0.001,138.263,0.0593,0.01,0.0183,2325.189,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-21",24,24,1313,,0.003,0.001,574.1,0.0594,0.023,0.0048,9656.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-22",6,5.97,340.29,,0.001,0.001,149.747,0.0592,0.007,0.0053,2518.834,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-24",15,14.7,744.5,,0.002,0.001,336.48,0.0591,0.019,0.0092,5665.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-25",24,24,1350,,0.003,0.001,586.2,0.0591,0.026,0.0052,9865.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-26",24,24,1315,,0.003,0.001,574.9,0.0592,0.023,0.0046,9673.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-27",24,24,1313,,0.003,0.001,575.6,0.0592,0.025,0.0051,9687.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-28",24,24,1258,,0.003,0.001,554,0.0592,0.023,0.0049,9323.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-29",24,24,1345,,0.003,0.001,585.8,0.0592,0.025,0.0052,9857.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-30",24,24,1323,,0.003,0.001,578.9,0.0594,0.026,0.0053,9740.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-07-31",24,24,1365,,0.003,0.001,594.1,0.0592,0.026,0.0053,9997.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-01",24,24,1324,,0.003,0.001,580.8,0.0591,0.025,0.005,9775.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-02",24,24,1262,,0.003,0.001,556.1,0.0593,0.022,0.0047,9355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-03",24,24,1317,,0.003,0.001,575.1,0.0592,0.026,0.0053,9680.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-04",24,24,1370,,0.003,0.001,595.4,0.059,0.027,0.0053,10025.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-05",24,24,1209,,0.003,0.001,536.3,0.0594,0.022,0.0048,9021.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-06",24,24,1196,,0.003,0.001,531.5,0.0593,0.023,0.0051,8942,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-07",24,24,1188,,0.003,0.001,530.4,0.0593,0.022,0.0049,8924.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-08",24,24,1326,,0.003,0.001,578,0.0592,0.026,0.0054,9722.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-09",24,24,1344,,0.003,0.001,581.9,0.0593,0.026,0.0052,9790.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-10",23,22.03,1168.93,,0.003,0.001,511.491,0.0592,0.022,0.005,8607.869,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-11",22,21.82,1147.94,,0.003,0.001,507.322,0.0593,0.026,0.0075,8537.506,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-12",24,24,1285,,0.003,0.001,565,0.0594,0.023,0.0049,9506.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-13",24,24,1310,,0.003,0.001,570.5,0.0593,0.024,0.005,9597.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-14",24,24,1314,,0.003,0.001,573.5,0.0592,0.025,0.0051,9650.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-15",24,24,1333,,0.003,0.001,583.3,0.0591,0.025,0.0051,9819.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-16",24,24,1282,,0.003,0.001,563,0.059,0.025,0.0052,9480.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-17",24,24,1312,,0.003,0.001,571.7,0.0591,0.024,0.005,9622.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-18",24,24,1286,,0.003,0.001,564,0.0593,0.025,0.0052,9487.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-19",24,24,1273,,0.003,0.001,559.7,0.0592,0.023,0.0048,9419.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-20",24,24,1337,,0.003,0.001,585.4,0.0591,0.025,0.005,9851.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-21",24,24,1317,,0.003,0.001,579.3,0.0593,0.026,0.0052,9746,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-22",24,24,1305,,0.003,0.001,575.1,0.0593,0.023,0.0048,9675.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-23",24,24,1305,,0.003,0.001,572.2,0.0592,0.024,0.005,9629.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-24",24,24,1372,,0.003,0.001,597.5,0.0592,0.027,0.0053,10055,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-25",24,24,1374,,0.003,0.001,596.9,0.0592,0.028,0.0056,10043.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-26",24,24,1372,,0.003,0.001,596.5,0.0592,0.029,0.0058,10037.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-27",24,24,1368,,0.003,0.001,596.6,0.0593,0.028,0.0056,10037.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-28",24,24,1375,,0.003,0.001,597.4,0.0592,0.027,0.0054,10053.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-29",24,24,1368,,0.003,0.001,600.7,0.0591,0.026,0.0051,10111.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-30",24,24,1382,,0.003,0.001,604.9,0.0591,0.028,0.0055,10181.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-08-31",24,24,1363,,0.003,0.001,605.9,0.0592,0.028,0.0055,10194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-01",24,24,1311,,0.003,0.001,589.2,0.0593,0.024,0.0048,9911.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-02",24,24,1317,,0.003,0.001,591.6,0.0593,0.025,0.005,9952.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-03",24,24,1275,,0.003,0.001,567.9,0.0592,0.022,0.0046,9555.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-04",24,24,990,,0.003,0.001,497,0.0592,0.02,0.0047,8364,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-05",24,24,1176,,0.003,0.001,529.9,0.0592,0.02,0.0045,8917.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-06",24,24,1143,,0.003,0.001,517.4,0.0592,0.021,0.0048,8706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-07",24,24,1258,,0.003,0.001,557.3,0.0593,0.021,0.0045,9377.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-08",24,24,1157,,0.003,0.001,521.2,0.0593,0.021,0.0049,8769.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-09",24,24,1124,,0.003,0.001,510.1,0.0592,0.022,0.005,8585.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-10",24,24,1152,,0.003,0.001,518.3,0.0595,0.021,0.0048,8717.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-11",24,24,1057,,0.002,0.001,481.3,0.0592,0.019,0.0048,8099,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-12",24,24,1121,,0.003,0.001,505.4,0.0594,0.021,0.005,8501,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-13",24,24,1109,,0.003,0.001,500.1,0.0592,0.019,0.0046,8414.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-14",24,24,1255,,0.003,0.001,554.4,0.0593,0.024,0.0051,9328.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-15",24,24,1215,,0.003,0.001,539.1,0.0593,0.023,0.005,9072.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-16",24,24,1247,,0.003,0.001,549.7,0.0594,0.024,0.0053,9247.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-17",24,24,1212,,0.003,0.001,537.6,0.0593,0.021,0.0047,9047.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-18",24,24,1171,,0.003,0.001,520.5,0.0592,0.021,0.0048,8759.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-19",24,24,1153,,0.003,0.001,515.3,0.0592,0.018,0.0042,8670.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-20",24,24,1133,,0.003,0.001,507.6,0.0592,0.018,0.0042,8541.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-21",15,14.28,707.84,,0.002,0.001,314.424,0.0592,0.011,0.0043,5289.788,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-23",17,16.82,893.58,,0.002,0.001,406.06,0.0591,0.021,0.0074,6833.816,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-24",24,24,1433,,0.003,0.001,629.3,0.0593,0.029,0.0054,10585.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-25",24,24,1251,,0.003,0.001,552.6,0.0592,0.021,0.0045,9297.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-26",24,24,1142,,0.003,0.001,510.3,0.0593,0.019,0.0045,8585.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-27",24,24,1169,,0.003,0.001,519.5,0.0592,0.022,0.0049,8740.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-28",24,24,1097,,0.002,0.001,494.8,0.0594,0.02,0.0048,8321.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-29",24,24,1167,,0.003,0.001,521,0.0593,0.021,0.0048,8765.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-09-30",24,24,964,,0.002,0.001,451,0.0594,0.019,0.005,7586.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-01",24,24,1085,,0.002,0.001,491.5,0.0592,0.022,0.0053,8270.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-02",24,24,1088,,0.002,0.001,492.3,0.059,0.019,0.0045,8287.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-03",24,24,1132,,0.003,0.001,506.9,0.0591,0.02,0.0046,8531.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-04",24,24,1233,,0.003,0.001,541.3,0.0591,0.024,0.0052,9110.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-05",24,24,1185,,0.003,0.001,523.8,0.0592,0.023,0.0051,8815.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-06",24,24,1136,,0.003,0.001,507.4,0.0591,0.018,0.0043,8543.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-07",24,24,1213,,0.003,0.001,537.6,0.0593,0.022,0.0048,9043.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-08",24,24,1283,,0.003,0.001,562.9,0.0591,0.024,0.005,9472.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-09",24,24,1165,,0.003,0.001,519.3,0.0594,0.02,0.0045,8735.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-10",24,24,1362,,0.003,0.001,605.4,0.0593,0.025,0.0048,10183.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-11",24,24,1378,,0.003,0.001,610.4,0.0595,0.025,0.0048,10263.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-12",24,24,1204,,0.003,0.001,546.4,0.0592,0.02,0.0043,9196.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-13",24,24,1205,,0.003,0.001,535,0.0593,0.022,0.0049,9002.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-14",24,24,1245,,0.003,0.001,548.1,0.0593,0.022,0.0048,9223.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-15",24,24,1157,,0.003,0.001,517.9,0.0593,0.021,0.0048,8717.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-16",24,24,1196,,0.003,0.001,531,0.0592,0.021,0.0048,8935.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-17",24,24,1168,,0.003,0.001,520.9,0.0591,0.021,0.0048,8766.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-18",24,24,1123,,0.003,0.001,503.6,0.0593,0.019,0.0045,8475.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-19",24,24,1101,,0.003,0.001,496.7,0.0591,0.018,0.0043,8360.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-20",24,24,1274,,0.003,0.001,559.6,0.0593,0.023,0.0049,9416.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-21",24,24,1166,,0.003,0.001,518.7,0.0592,0.019,0.0044,8733.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-22",11,10.82,488.16,,0.001,0.001,222.116,0.0591,0.008,0.004,3737.284,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-02",14,13.98,683.54,,0.002,0.001,306.632,0.0591,0.018,0.0089,5159.194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-03",24,24,1188,,0.003,0.001,528.8,0.0593,0.022,0.0049,8895.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-04",24,24,996,,0.002,0.001,460.2,0.0591,0.017,0.0045,7745.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-05",24,24,1007,,0.002,0.001,464.3,0.0594,0.019,0.0048,7809.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-06",24,24,1181,,0.003,0.001,525.9,0.0593,0.021,0.0046,8848.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-07",24,24,1009,,0.002,0.001,473.9,0.0593,0.018,0.0045,7972.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-08",24,24,1165,,0.003,0.001,535.3,0.0593,0.022,0.0048,9006.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-09",24,24,967,,0.002,0.001,463.3,0.0593,0.019,0.005,7795.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-10",24,24,1365,,0.003,0.001,605.5,0.0591,0.024,0.0047,10194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-11",24,24,1236,,0.003,0.001,558.3,0.0592,0.023,0.0048,9395.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-12",4,3.6,151.6,,0,0.001,72.78,0.0593,0.003,0.0053,1224.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-13",2,0.38,0,,0,0.001,0.938,0.0605,0,0.045,15.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"3-2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-11",19,17.52,145.52,,0.001,0.001,151.642,0.0595,0.2,0.3403,2550.616,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-12",24,24,854,,0.003,0.001,544.4,0.0592,0.232,0.0498,9162.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-13",24,24,1049,,0.003,0.001,646.6,0.059,0.279,0.0501,10884.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-14",24,24,969,,0.003,0.001,598.8,0.0592,0.251,0.0502,10078.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-15",24,24,913,,0.003,0.001,573.8,0.0591,0.239,0.0497,9658,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-16",24,24,953,,0.003,0.001,600.8,0.0593,1.615,0.3095,10110.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-17",21,20.92,563.72,,0.002,0.001,372.748,0.0594,0.905,0.2934,6270.048,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-20",2,0.23,0.23,,0,0.001,2.637,0.059,0.015,0.647,44.366,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-27",19,17,114,,0.001,0.001,127.283,0.0596,0.169,0.2838,2139,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-28",24,24,589,,0.002,0.001,385.1,0.0593,0.166,0.0519,6479.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-29",24,24,800,,0.003,0.001,504.1,0.0591,0.188,0.0465,8486.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-30",24,24,693,,0.002,0.001,440.2,0.0594,0.21,0.0588,7402.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-05-31",24,24,687,,0.002,0.001,435.4,0.0593,0.195,0.0551,7326.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-01",24,24,629,,0.002,0.001,411.3,0.0592,0.688,0.2054,6922.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-02",24,24,672,,0.002,0.001,440.6,0.0593,0.171,0.0457,7416.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-03",24,24,644,,0.002,0.001,417,0.0593,0.198,0.056,7017.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-04",24,24,616,,0.002,0.001,397.1,0.0594,0.183,0.0553,6681.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-05",20,19.95,671.05,,0.002,0.001,426.835,0.0592,0.2,0.0527,7183.915,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-22",11,10.85,10.85,,0,0.001,47.795,0.0595,0.039,0.0893,803.61,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-23",24,24,564,,0.002,0.001,388.4,0.0593,0.164,0.055,6537.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-24",24,24,761,,0.002,0.001,487,0.0593,0.226,0.0541,8195.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-25",24,24,596,,0.002,0.001,389.4,0.0594,0.205,0.0625,6552.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-26",24,24,608,,0.002,0.001,393.5,0.0593,0.185,0.0562,6621.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-27",24,24,597,,0.002,0.001,387.8,0.0593,0.164,0.0502,6525.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-28",24,24,622,,0.002,0.001,403,0.0593,0.135,0.0395,6782.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-29",24,24,720,,0.002,0.001,470,0.0593,0.166,0.0413,7907.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-30",24,24,718,,0.002,0.001,470.4,0.0593,0.177,0.0432,7914.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-07-31",24,24,725,,0.002,0.001,471.6,0.0593,0.208,0.0523,7936.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-01",24,24,612,,0.002,0.001,408.6,0.0593,0.178,0.0518,6875.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-02",24,24,600,,0.002,0.001,391.5,0.0593,0.163,0.0496,6588.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-03",24,24,635,,0.002,0.001,411,0.0593,0.165,0.0467,6916.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-04",24,24,733,,0.002,0.001,475.4,0.0592,0.185,0.043,7998.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-05",24,24,650,,0.002,0.001,426.5,0.0591,0.17,0.0461,7181.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-06",24,24,622,,0.002,0.001,411.1,0.0593,0.138,0.0402,6915.3,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-07",1,0.58,10.44,,0,0.001,7.25,0.059,0.002,0.029,122.09,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-11",2,1.55,1.55,,0,0.001,6.01,0.0595,0.001,0.021,101.62,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-12",24,24,280,,0.001,0.001,254.3,0.0595,0.13,0.0682,4277.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-13",24,24,706,,0.002,0.001,464.9,0.0592,0.17,0.0426,7825.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-14",24,24,757,,0.002,0.001,493.6,0.0592,0.137,0.034,8308,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-15",24,24,594,,0.002,0.001,408.6,0.0595,0.148,0.0446,6872.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-16",24,24,619,,0.002,0.001,415,0.0593,0.153,0.0437,6985.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-17",24,24,631,,0.002,0.001,419.3,0.0593,0.156,0.0439,7055.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-18",24,24,681,,0.002,0.001,448.2,0.0595,0.181,0.0474,7535.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-19",24,24,620,,0.002,0.001,415.2,0.0593,0.162,0.046,6987.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-20",24,24,607,,0.002,0.001,407.9,0.0593,0.176,0.0511,6865.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-21",24,24,605,,0.002,0.001,406.8,0.0593,0.156,0.0456,6846.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-22",24,24,713,,0.002,0.001,469.3,0.0593,0.211,0.0523,7899.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-23",24,24,778,,0.003,0.001,509.9,0.0594,0.249,0.0582,8575.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-24",24,24,686,,0.002,0.001,451.3,0.0593,0.173,0.0469,7593.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-25",24,24,856,,0.003,0.001,551.9,0.0592,0.209,0.0415,9290.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-26",24,24,836,,0.003,0.001,534.9,0.0593,0.264,0.0566,8998.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-27",24,24,779,,0.003,0.001,501.4,0.0593,0.224,0.0531,8436.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-28",24,24,697,,0.002,0.001,453.7,0.0592,0.212,0.0562,7638.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-29",24,24,626,,0.002,0.001,420.1,0.0593,0.153,0.0432,7070,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-30",24,24,602,,0.002,0.001,404.7,0.0593,0.161,0.0473,6807.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-08-31",24,24,604,,0.002,0.001,404.9,0.0591,0.134,0.0394,6816.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-01",24,24,595,,0.002,0.001,397.7,0.0594,0.152,0.0454,6693.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-02",24,24,593,,0.002,0.001,401.6,0.0595,0.166,0.049,6749.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-03",24,24,592,,0.002,0.001,399.6,0.0594,0.173,0.0515,6720.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-04",24,24,600,,0.002,0.001,399.5,0.0593,0.2,0.0595,6722.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-05",24,24,629,,0.002,0.001,415.7,0.0593,0.204,0.0584,6993.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-06",24,24,627,,0.002,0.001,417.2,0.0593,0.203,0.0577,7022.9,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-07",24,24,594,,0.002,0.001,401.7,0.0592,0.159,0.0471,6765.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-08",20,19.07,463.14,,0.002,0.001,313.171,0.0593,0.119,0.0432,5267.365,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-18",12,9.84,9.84,,0,0.001,37.299,0.0593,0.026,0.083,629.524,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-19",24,24,419,,0.002,0.001,318.8,0.0593,0.112,0.0479,5363.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-20",24,24,778,,0.002,0.001,494.4,0.0592,0.126,0.0293,8319.2,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-21",24,24,648,,0.002,0.001,421.7,0.0593,0.117,0.0324,7094.5,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-22",24,24,744,,0.003,0.001,499.1,0.0592,0.16,0.038,8396.6,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-23",24,24,776,,0.003,0.001,515.6,0.0592,0.154,0.036,8676.8,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-24",24,24,1004,,0.003,0.001,651.9,0.0593,0.227,0.0409,10967,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-25",24,24,759,,0.003,0.001,496.2,0.0593,0.2,0.0478,8349.1,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-26",24,24,625,,0.002,0.001,416.7,0.0593,0.183,0.0525,7012.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-27",24,24,656,,0.002,0.001,438.6,0.0594,0.183,0.0497,7379.7,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-28",24,24,666,,0.002,0.001,441.2,0.0593,0.205,0.0553,7423.4,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-29",22,21.45,633.4,,0.002,0.001,415.895,0.0593,0.169,0.0479,6997.48,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","El Centro",389,"4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Residual Oil","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-06",4,2.32,64.1,,0,0.001,44.09,0.059,0.016,0.047,741.712,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-15",6,4.54,191.58,,0.001,0.001,112.309,0.0582,0.021,0.0273,1926.537,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-24",1,0.67,0,,0,0.001,4.087,0.059,0.008,0.222,69.479,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-18",7,5.83,251.24,,0.001,0.001,147.408,0.058,0.027,0.0237,2527.198,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-27",11,10.52,469.43,,0.001,0.001,272.446,0.058,0.045,0.0208,4670.168,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-03",18,17.66,808.44,,0.002,0.001,457.959,0.058,0.068,0.0183,7848.717,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-11",3,1.84,43.36,,0,0.001,31.294,0.06,0.012,0.0453,523.709,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-13",14,12.8,575.3,,0.002,0.001,329.12,0.058,0.043,0.0161,5640.09,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-18",5,3.76,157.4,,0,0.001,95.14,0.058,0.023,0.032,1630.492,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-23",2,1.57,28.56,,0,0.001,25.495,0.062,0.015,0.072,419.79,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-14",3,1.7,33.23,,0,0.001,27.994,0.059,0.012,0.048,466.526,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-10",8,6.58,287.62,,0.001,0.001,170.598,0.058,0.021,0.0189,2923.98,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-11",3,1.73,32.04,,0,0.001,28.866,0.0593,0.012,0.049,482.217,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-22",5,3.8,155.88,,0,0.001,96.869,0.058,0.016,0.0236,1659.92,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-06",5,4.12,164.52,,0.001,0.001,104.552,0.058,0.021,0.0312,1791.172,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-09",3,1.78,38.34,,0,0.001,31.875,0.059,0.013,0.0557,531.306,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-10",11,9.52,426.2,,0.001,0.001,247.06,0.0581,0.033,0.0154,4234.008,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-17",2,1.32,35.58,,0,0.001,30.378,0.058,0.012,0.0545,520.626,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-21",14,12.63,573.9,,0.002,0.001,328.383,0.058,0.044,0.0184,5629.738,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-23",4,2.75,107.44,,0,0.001,65.832,0.058,0.014,0.0183,1130.019,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-01",3,1.8,63.16,,0,0.001,41.324,0.0583,0.01,0.0197,708.56,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-03",6,4.73,200.38,,0.001,0.001,119.324,0.058,0.018,0.0173,2045.063,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-13",7,5.98,257.62,,0.001,0.001,150.858,0.058,0.022,0.0174,2584.784,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-14",6,5.45,231.6,,0.001,0.001,138.951,0.058,0.023,0.0208,2381.71,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-15",7,6.35,280.47,,0.001,0.001,161.328,0.058,0.022,0.0236,2764.712,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-17",8,5.11,141.62,,0.001,0.001,99.494,0.0586,0.024,0.033,1685.904,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-18",7,6.6,270.61,,0.001,0.001,161.168,0.058,0.022,0.0177,2761.006,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-19",5,4.16,179.32,,0.001,0.001,105.324,0.058,0.018,0.02,1804.77,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-20",6,5.25,217.5,,0.001,0.001,132.86,0.058,0.019,0.0207,2276.77,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-21",5,3.96,158.88,,0,0.001,97.256,0.058,0.023,0.0336,1666.724,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-22",8,6.77,290.73,,0.001,0.001,171.925,0.058,0.025,0.0248,2947.406,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-23",7,6.17,261.2,,0.001,0.001,157.647,0.058,0.022,0.0181,2703.394,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-24",6,5.3,223.84,,0.001,0.001,135.6,0.058,0.022,0.0202,2323.58,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-26",5,3.52,145.82,,0,0.001,88.388,0.058,0.015,0.0256,1513.7,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-05",9,8.6,382.9,,0.001,0.001,221.525,0.058,0.031,0.0201,3797.34,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-06",6,5.29,226.1,,0.001,0.001,132.444,0.0582,0.017,0.025,2269.99,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-08",7,5.18,234,,0.001,0.001,130.651,0.058,0.021,0.0206,2238.372,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-11",3,2.09,85.71,,0,0.001,49.322,0.058,0.01,0.022,845.792,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-16",7,5.78,246.97,,0.001,0.001,146.632,0.058,0.022,0.0229,2513.903,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-17",5,3.2,135.85,,0,0.0008,78.837,0.058,0.016,0.0176,1350.868,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-18",6,5.08,222.06,,0.001,0.001,126.948,0.0582,0.017,0.0175,2176.68,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-19",5,3.12,136,,0,0.001,76.591,0.0582,0.015,0.0166,1312.35,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-20",8,7.15,318.55,,0.001,0.001,181.73,0.058,0.026,0.0165,3112.38,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-24",2,1.55,27.9,,0,0.001,25.916,0.06,0.014,0.0655,432.078,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-29",4,3.12,133,,0,0.001,74.872,0.058,0.013,0.0178,1283.292,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-01",5,3.56,146.06,,0,0.001,89.576,0.058,0.013,0.026,1535.046,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-02",4,1.9,39.64,,0,0.001,35.006,0.0583,0.012,0.073,601.028,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-03",5,3.6,151.6,,0,0.001,89.924,0.0582,0.015,0.0216,1541.55,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-05",5,4.08,172.32,,0.001,0.001,102.616,0.058,0.02,0.0226,1759.572,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-06",5,3.92,156.92,,0,0.001,95.84,0.058,0.021,0.0306,1641.685,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-07",1,0.43,1.72,,0,0.001,3.999,0.058,0.003,0.09,68.456,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-15",3,1.38,37.74,,0,0.001,31.694,0.0583,0.008,0.026,543.53,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-16",2,1.95,78.85,,0,0.001,46.72,0.058,0.01,0.026,799.865,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-19",2,0.95,24.4,,0,0.001,20.39,0.058,0.008,0.079,349.995,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-21",8,6.98,217.3,,0.001,0.001,136.898,0.0581,0.023,0.0189,2345.466,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-14",3,1.67,35.35,,0,0.001,28.085,0.059,0.011,0.0463,468.896,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"10",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10A",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-15",19,17.91,1792.44,,0.005,0.001,969.605,0.0583,0.152,0.0178,16558.749,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-12",4,2.57,155.4,,0.001,0.001,124.802,0.0588,0.071,0.043,2096.077,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-26",2,1.98,112.74,,0.001,0.001,90.042,0.061,0.078,0.098,1482.274,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-16",17,16.25,1625.8,,0.005,0.001,885.34,0.058,0.17,0.0287,15177.28,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-25",3,1.74,77.02,,0,0.001,74.064,0.059,0.06,0.0537,1230.64,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-09",4,2.1,116,,0.001,0.001,92.55,0.0603,0.069,0.0413,1516.091,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-13",3,1.82,86,,0.001,0.001,76.838,0.061,0.063,0.055,1260.26,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-18",12,10.2,937,,0.003,0.0009,522.363,0.058,0.083,0.0176,8954.666,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-19",11,10.6,1043.89,,0.003,0.001,566.936,0.058,0.093,0.0228,9716.004,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-03",12,10.57,963.3,,0.003,0.0009,541.223,0.058,0.072,0.0143,9276.387,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-04",11,9.58,897.14,,0.003,0.001,497.434,0.0581,0.073,0.0156,8528.64,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-10",3,2.13,128,,0.001,0.001,99.213,0.0597,0.047,0.0377,1643.868,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-08",1,0.48,0,,0,0.001,5.664,0.058,0.002,0.038,97.056,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-16",6,4.2,280,,0.001,0.001,197.73,0.0587,0.053,0.0223,3342.97,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-21",12,10.41,968.8,,0.003,0.001,529.425,0.058,0.083,0.0163,9076.582,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-07-31",7,5.4,448.96,,0.001,0.001,266.14,0.0581,0.081,0.0429,4560.813,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-01",4,3.06,211.52,,0.001,0.001,141.476,0.058,0.039,0.0415,2424.774,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-03",8,6.38,534.75,,0.002,0.001,306.67,0.058,0.074,0.0253,5258.107,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-13",8,6.95,593.38,,0.002,0.001,347.619,0.058,0.065,0.0201,5960.25,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-14",10,8.34,760.54,,0.002,0.001,413.177,0.058,0.064,0.0153,7081.508,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-15",11,9.37,850.89,,0.002,0.001,464.484,0.058,0.072,0.0155,7961.669,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-16",8,6.96,608.72,,0.002,0.001,340.526,0.058,0.057,0.0198,5835.96,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-17",9,7.96,704.04,,0.002,0.001,390.38,0.058,0.059,0.0186,6691.052,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-18",9,8.83,783.91,,0.002,0.001,429.347,0.058,0.086,0.0241,7360.918,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-19",10,7.01,521.25,,0.002,0.001,321.118,0.0586,0.064,0.0245,5450.85,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-23",11,9.54,824.1,,0.002,0.001,461.084,0.058,0.072,0.0173,7902.806,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-24",7,6.38,538.55,,0.002,0.001,307.418,0.058,0.059,0.022,5268.025,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-25",7,6.1,508.05,,0.001,0.001,288.345,0.058,0.052,0.0206,4941.08,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-26",7,5.51,452.02,,0.001,0.001,259.736,0.058,0.063,0.0226,4450.696,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-27",11,10.43,949.41,,0.003,0.001,519.434,0.058,0.095,0.0255,8903.697,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-28",5,3.3,258.5,,0.001,0.001,150.03,0.0582,0.043,0.0484,2571.085,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-04",8,6.32,533.7,,0.002,0.0009,308.238,0.0581,0.046,0.015,5284.764,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-05",6,4.5,366,,0.001,0.001,210.554,0.058,0.062,0.0245,3609.78,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-06",10,8.28,729.4,,0.002,0.001,402.168,0.058,0.067,0.0159,6894.304,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-07",9,7.68,672.68,,0.002,0.001,371.942,0.058,0.068,0.0259,6374.506,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-16",8,6.27,538.34,,0.002,0.001,308.204,0.058,0.063,0.0188,5281.703,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-18",11,9.06,825,,0.002,0.001,454.361,0.0579,0.073,0.0156,7786.221,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-19",10,9.51,866.46,,0.002,0.001,471.063,0.058,0.08,0.0233,8075.219,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-20",11,9.9,907.04,,0.003,0.001,495.368,0.058,0.1,0.0268,8489.192,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-25",9,7.88,692.26,,0.002,0.001,391.014,0.058,0.093,0.0248,6701.997,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-09-30",4,2.21,102.69,,0.001,0.001,96.472,0.0593,0.054,0.0383,1602.283,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-01",8,6.94,586.62,,0.002,0.001,343.648,0.058,0.062,0.0203,5889.978,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-02",5,4.58,364.36,,0.001,0.001,218.806,0.058,0.039,0.0216,3750.586,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-09",1,0.23,0,,0,0.001,2.162,0.058,0,0.011,37.076,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-15",6,4.64,345.76,,0.001,0.001,230.309,0.058,0.048,0.0213,3946.112,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-16",6,5.07,393.28,,0.001,0.001,237.43,0.058,0.069,0.0433,4068.103,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-16",7,4.58,303.56,,0.001,0.001,205.77,0.058,0.049,0.0324,3527.644,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-24",1,0.68,0,,0,0.003,3.4,0.081,0,0.009,41.752,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-16",4,2.17,108.15,,0.001,0.001,102.22,0.058,0.052,0.0533,1752.503,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"**10B",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-06",2,1.71,29.5,,0,0.001,26.466,0.0615,0.017,0.074,436.001,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-15",1,0.25,0.25,,0,0.001,1.925,0.058,0.002,0.095,32.975,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-16",4,1.94,43.98,,0,0.001,41.229,0.0578,0.011,0.0308,707.114,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-03",6,4.8,208.5,,0.001,0.001,124.88,0.058,0.024,0.0205,2140.65,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-04",8,7.93,361.55,,0.001,0.001,208.218,0.058,0.037,0.0225,3569.496,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-05",1,0.5,11,,0,0.001,12.4,0.058,0.002,0.015,212.85,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-06",13,12.05,538,,0.002,0.001,316.652,0.058,0.054,0.0236,5426.099,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-07",15,14.4,654.81,,0.002,0.001,381.07,0.058,0.057,0.0178,6532.647,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-09",7,6.78,253.5,,0.001,0.001,151.866,0.058,0.03,0.0253,2603.238,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-10",2,1.12,39.36,,0,0.001,24.644,0.058,0.003,0.012,423.152,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-18",2,0.37,0,,0,0.001,2.294,0.058,0.001,0.0575,39.486,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-12",2,1.57,51.13,,0,0.001,36.86,0.058,0.01,0.0325,631.816,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-13",2,1.32,35.05,,0,0.001,29.941,0.058,0.016,0.07,514.084,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-17",16,14.95,683.26,,0.002,0.001,387.231,0.058,0.05,0.0153,6636.974,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-23",3,1.58,33.25,,0,0.001,25.984,0.0603,0.016,0.057,427.171,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-23",3,1.57,32.8,,0,0.001,24.992,0.0613,0.015,0.0603,407.281,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-14",3,1.65,31.89,,0,0.001,26.773,0.059,0.01,0.046,442.88,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-25",3,1.86,72.71,,0,0.001,44.464,0.058,0.014,0.0257,761.643,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-02",6,4.56,194.88,,0.001,0.001,114.396,0.058,0.02,0.026,1960.5,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-16",3,1.32,23.32,,0,0.001,19.884,0.0597,0.006,0.022,322.256,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-25",5,3.29,115.04,,0,0.001,76.157,0.058,0.015,0.0326,1305.586,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-06",8,7.02,302.55,,0.001,0.001,179.046,0.058,0.019,0.0183,3071.407,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-08",2,0.97,17.55,,0,0.001,21.212,0.058,0.007,0.0415,363.776,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-09",2,1.63,32.82,,0,0.001,27.891,0.0605,0.01,0.045,464.701,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-10",5,3.91,160.04,,0.001,0.001,97.166,0.058,0.011,0.0252,1666.074,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-22",12,10.75,486.24,,0.001,0.001,273.383,0.058,0.037,0.0202,4688.707,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-01",2,0.95,14.69,,0,0.001,18.334,0.058,0.008,0.061,314.077,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-14",6,4.77,164.64,,0.001,0.001,102.268,0.058,0.016,0.0265,1752.099,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-15",7,5.92,212.56,,0.001,0.001,126.385,0.058,0.018,0.0219,2167.028,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-17",4,2.47,80.28,,0,0.001,50.82,0.058,0.006,0.0285,870.588,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-18",7,5.43,185.72,,0.001,0.001,111.467,0.058,0.013,0.0281,1910.41,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-19",3,2.19,73.36,,0,0.001,44.025,0.0583,0.007,0.035,755.499,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-24",5,3.8,127.08,,0,0.001,80.04,0.058,0.008,0.0246,1371.82,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-05",9,8.09,367.71,,0.001,0.001,201.755,0.0581,0.027,0.0176,3458.196,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-06",7,5.2,227.07,,0.001,0.001,126.862,0.058,0.019,0.0194,2173.005,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-09",8,6.84,301.6,,0.001,0.001,167.905,0.058,0.02,0.0191,2876.967,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-11",3,2.05,86.68,,0,0.001,47.695,0.058,0.011,0.0257,818.017,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-16",6,4.75,201.54,,0.001,0.001,115.783,0.058,0.021,0.026,1987.143,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-17",3,1.43,50.85,,0,0.001,32.17,0.058,0.008,0.0397,550.383,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-18",6,4.77,192.21,,0.001,0.001,112.113,0.058,0.022,0.0255,1922.372,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-19",4,2.23,90.6,,0,0.001,52.751,0.0583,0.009,0.014,904.51,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-20",8,6.2,278.36,,0.001,0.001,152.068,0.058,0.019,0.0146,2605.464,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-29",5,3.58,149,,0,0.001,86.348,0.0582,0.013,0.017,1478.874,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-15",2,1.33,37.24,,0,0.001,31.984,0.058,0.007,0.0245,548.967,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-16",2,1.93,79.07,,0,0.001,45.613,0.058,0.009,0.0245,782.85,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-20",8,6.55,223.73,,0.001,0.001,136.529,0.058,0.016,0.021,2338.225,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-02",3,2.07,77.11,,0,0.001,49.467,0.058,0.015,0.0303,847.861,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-03",3,1.48,53.11,,0,0.001,35.222,0.0583,0.009,0.033,603.296,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-05",5,4.03,172.12,,0.001,0.001,98.336,0.058,0.018,0.0206,1686.897,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-14",3,1.6,27.4,,0,0.0017,25.21,0.0673,0.013,0.081,395.91,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-15",2,0.87,19.83,,0,0.001,17.632,0.058,0.005,0.049,301.786,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"11",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-07",3,1.64,32.34,,0,0.001,27.326,0.06,0.01,0.0503,451.44,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-03",5,4.03,182,,0.001,0.0008,103.332,0.058,0.019,0.0176,1772.659,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-04",1,0.08,0.16,,0,0.001,1.2,0.058,0,0.014,20.552,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-09",7,6.68,297.64,,0.001,0.001,172.64,0.058,0.036,0.0303,2957.688,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-10",14,12.87,570.04,,0.002,0.001,331.272,0.058,0.049,0.0184,5677.12,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-05",4,1.7,28.42,,0,0.001,27.16,0.0598,0.018,0.0873,442.064,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-13",2,0.52,0,,0,0.001,3.028,0.058,0.004,0.093,52.194,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-07",3,2.02,73.1,,0,0.001,49.848,0.0583,0.013,0.0497,853.944,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-15",6,3.28,57.06,,0,0.001,53.675,0.0588,0.024,0.0653,902.72,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-11",4,1.83,25.92,,0,0.0008,27.734,0.0603,0.021,0.0968,454.268,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-25",2,1.83,70.71,,0,0.001,45.546,0.058,0.011,0.027,780.487,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-02",6,4.62,196,,0.001,0.001,120.75,0.058,0.019,0.0208,2069.51,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-03",2,0.47,1.99,,0,0.001,6.468,0.0585,0.005,0.1075,110.824,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-04",9,8.08,348.57,,0.001,0.001,211.751,0.058,0.029,0.0227,3628.37,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-08",3,1.98,83.1,,0,0.001,49.995,0.058,0.013,0.0237,858.332,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-09",5,3.56,147.11,,0,0.001,92.153,0.058,0.019,0.0344,1578.627,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-10",7,6.38,276.82,,0.001,0.001,168.072,0.058,0.018,0.018,2879.7,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-11",6,4.21,124.41,,0.001,0.001,92.091,0.059,0.014,0.027,1559.626,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-23",7,5.33,233.5,,0.001,0.001,140.237,0.0581,0.016,0.0137,2404.361,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-24",6,4.9,214.3,,0.001,0.0008,127.785,0.058,0.014,0.011,2190.695,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-06",9,7.86,344.7,,0.001,0.001,209.62,0.058,0.023,0.0158,3589.786,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-07",4,2.82,111.86,,0,0.001,71.762,0.0583,0.01,0.0183,1229.202,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-10",5,3.91,160.32,,0.001,0.001,102.138,0.058,0.012,0.0242,1750.631,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-23",12,11.55,518.77,,0.002,0.001,306.796,0.058,0.03,0.0119,5259.344,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-27",3,1.87,40.39,,0,0.001,30.627,0.0603,0.011,0.0393,510.567,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-01",3,1.63,54.65,,0,0.001,39.114,0.058,0.008,0.017,670.276,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-03",7,5.22,234.07,,0.001,0.001,136.353,0.058,0.015,0.0174,2336.479,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-13",7,5.93,253.12,,0.001,0.001,152.194,0.058,0.018,0.0147,2607.547,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-14",7,5.61,240.08,,0.001,0.001,145.332,0.058,0.02,0.019,2490.371,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-15",8,6.65,289.95,,0.001,0.001,174.405,0.058,0.029,0.0248,2987.155,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-17",5,3.94,172.72,,0.001,0.0008,101.286,0.058,0.013,0.0124,1737.046,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-18",7,6.55,269.8,,0.001,0.001,164.165,0.058,0.022,0.0176,2814.105,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-19",5,4.15,180.24,,0.001,0.001,107.398,0.058,0.015,0.0158,1841.25,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-20",6,5.17,215.43,,0.001,0.001,134.501,0.058,0.015,0.0172,2304.595,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-21",4,3.29,127.07,,0,0.001,83.15,0.058,0.017,0.032,1425.708,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-22",8,6.73,290.76,,0.001,0.001,176.656,0.058,0.02,0.0195,3027.242,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-23",7,6.2,262.65,,0.001,0.001,161.685,0.058,0.017,0.0137,2771.986,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-24",9,5.81,191.26,,0.001,0.0011,129.498,0.0604,0.026,0.0482,2188.866,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-26",5,3.52,145.92,,0,0.001,90.084,0.058,0.012,0.0224,1545.268,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-05",9,8.38,359.2,,0.001,0.001,216.774,0.058,0.031,0.0218,3715.556,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-06",6,5.27,225.63,,0.001,0.001,134.945,0.058,0.016,0.0282,2311.479,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-09",1,1,0,,0,0.001,1.7,0.058,0.002,0.158,29.3,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-10",7,6.08,262.88,,0.001,0.001,157.397,0.058,0.02,0.0227,2695.735,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-11",3,1.99,82.71,,0,0.0007,48.475,0.058,0.009,0.015,830.905,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-16",7,5.76,246.08,,0.001,0.001,148.279,0.058,0.019,0.0186,2540.289,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-17",3,1.55,51.75,,0,0.001,36.605,0.058,0.008,0.04,626.75,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-18",6,4.99,218.2,,0.001,0.001,126.631,0.0582,0.016,0.0143,2168.439,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-19",5,3.5,142.74,,0,0.001,88.121,0.0582,0.013,0.015,1510.575,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-20",8,7.09,319.22,,0.001,0.001,183.595,0.058,0.023,0.0145,3146.315,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-28",2,1.65,30.2,,0,0.001,27.17,0.0615,0.017,0.0715,446.48,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-29",5,3.6,146.6,,0,0.001,89.28,0.058,0.014,0.0254,1531.16,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-09-30",3,2.01,77.44,,0,0.001,49.251,0.058,0.012,0.026,845.163,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-01",5,3.6,146.8,,0,0.001,91.64,0.058,0.014,0.0282,1571.74,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-02",4,2.37,63.05,,0,0.001,50.296,0.058,0.016,0.037,862.646,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-05",5,4.08,172.32,,0.001,0.001,103.936,0.058,0.016,0.0184,1782.772,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-06",5,3.8,155.9,,0,0.001,96.982,0.058,0.017,0.0262,1661.966,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-07",1,0.27,0,,0,0.001,1.377,0.058,0.001,0.069,23.787,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-15",3,1.36,36.24,,0,0.0007,32.014,0.0583,0.011,0.0353,548.955,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-19",7,5.78,192.09,,0.001,0.001,121.865,0.058,0.015,0.0127,2089.79,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-02",3,2,68.8,,0,0.001,49.308,0.058,0.011,0.0273,843.928,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-03",3,1.5,52.17,,0,0.001,35.627,0.058,0.009,0.0337,610.131,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-05",5,4.05,173.25,,0.001,0.001,102.89,0.058,0.016,0.018,1763.955,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-21",3,1.67,35.2,,0,0.0007,27.346,0.06,0.012,0.0317,456.294,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"12",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-07",3,1.69,33.6,,0,0.001,26.259,0.06,0.014,0.052,435.875,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-15",5,4.08,172.14,,0.001,0.001,101.304,0.058,0.025,0.0282,1737.362,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-03",5,4.37,177.7,,0.001,0.001,107.757,0.058,0.026,0.0416,1847.261,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-04",8,7.55,328.81,,0.001,0.001,191.683,0.058,0.038,0.0244,3287.199,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-09",8,7.22,329.22,,0.001,0.001,185.86,0.0581,0.033,0.0279,3185.386,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-10",4,2.25,76.7,,0,0.001,48.065,0.0583,0.014,0.026,824.905,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-12",3,2.45,92.49,,0,0.001,59.165,0.058,0.016,0.0307,1013.613,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-17",3,1.32,48.35,,0,0.001,30.157,0.058,0.01,0.0467,517.244,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-05",2,1.75,35.16,,0,0.001,28.091,0.061,0.019,0.073,467.671,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-17",3,1.62,53.56,,0,0.001,37.02,0.058,0.015,0.0513,634.188,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-07",1,0.47,0,,0,0.001,2.961,0.058,0.005,0.193,50.948,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-04-30",4,3.17,122.23,,0,0.001,74.264,0.058,0.022,0.0328,1272.999,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-11",2,1.64,28.02,,0,0.001,26.382,0.0605,0.019,0.085,437.462,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-12",8,7.35,319.25,,0.001,0.001,188.345,0.058,0.03,0.0236,3229.475,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-20",11,10.58,408.44,,0.001,0.001,244.382,0.058,0.019,0.0111,4191.234,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-21",12,11.55,446.77,,0.001,0.001,265.932,0.058,0.052,0.026,4557.509,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-28",4,2.57,98.68,,0,0.001,63.073,0.058,0.011,0.0323,1081.412,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-04",9,8.1,353.34,,0.001,0.001,211.23,0.058,0.032,0.0243,3621.4,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-08",3,1.97,78.5,,0,0.001,47.536,0.058,0.015,0.029,814.636,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-09",5,3.6,147,,0,0.001,90.75,0.058,0.018,0.0342,1553.535,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-10",2,0.4,1.12,,0,0.001,4.036,0.058,0.003,0.06,69.264,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-11",3,2.25,77.76,,0,0.001,54.167,0.058,0.012,0.0413,927.862,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-16",2,1.27,13.05,,0,0.001,18.28,0.062,0.005,0.035,296.754,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-17",3,2.29,76.4,,0,0.001,55.151,0.058,0.005,0.011,945.236,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-06",9,7.61,335.6,,0.001,0.001,197.848,0.058,0.026,0.0192,3389.619,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-07",4,2.82,109.63,,0,0.001,70.405,0.058,0.017,0.033,1206.791,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-10",11,9.52,425.46,,0.001,0.001,248.912,0.058,0.027,0.0135,4266.092,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-22",2,1.12,36.86,,0,0.001,23.36,0.058,0.009,0.0385,400.113,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-27",3,2.25,35.65,,0,0.001,34.485,0.0593,0.015,0.049,574.15,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-01",3,1.49,47.88,,0,0.001,33.271,0.058,0.008,0.017,571.312,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-03",6,4.85,205.44,,0.001,0.001,121.968,0.0582,0.016,0.0167,2090.944,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-13",7,5.93,238.6,,0.001,0.001,140.787,0.058,0.019,0.0196,2413.957,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-14",7,5.71,244.18,,0.001,0.001,143.916,0.058,0.02,0.018,2466.726,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-15",8,7.08,302.26,,0.001,0.001,181.86,0.058,0.029,0.024,3115.428,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-17",4,3.6,146.2,,0,0.001,88.02,0.058,0.015,0.0193,1508.76,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-18",6,5.33,214.72,,0.001,0.001,129.545,0.058,0.023,0.0272,2219.479,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-19",5,4.03,165.7,,0.001,0.001,99.448,0.058,0.016,0.0196,1704.821,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-20",6,5.15,215.3,,0.001,0.001,131.86,0.058,0.017,0.0222,2260.475,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-23",6,5.33,229.97,,0.001,0.001,134.178,0.058,0.018,0.0158,2300.552,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-24",10,7.69,277,,0.001,0.001,175.596,0.0584,0.027,0.0221,2997.717,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-28",4,2.6,98.47,,0,0.001,62.705,0.058,0.008,0.0275,1076.397,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-05",7,5.73,234.86,,0.001,0.001,138.748,0.058,0.039,0.0294,2376.501,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-06",7,5.19,226.07,,0.001,0.001,129.249,0.0581,0.02,0.0164,2214.148,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-14",4,1.95,39.17,,0,0.001,35.594,0.0585,0.013,0.0405,610.598,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-15",4,1.86,34.34,,0,0.001,35.212,0.0583,0.018,0.0503,602.927,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-16",6,4.81,199.36,,0.001,0.001,117.66,0.058,0.022,0.0298,2016.294,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-18",9,7.96,348.58,,0.001,0.001,200.966,0.0581,0.032,0.0217,3443.52,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-19",4,2.52,95.46,,0,0.001,60.399,0.058,0.014,0.02,1036.318,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-20",6,5.08,216.51,,0.001,0.001,125.64,0.058,0.021,0.0278,2154.299,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-01",3,2.56,43.74,,0,0.0013,36.99,0.0617,0.014,0.0467,613.5,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-02",4,1.9,42.17,,0,0.001,36.462,0.058,0.009,0.0435,625.854,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-03",5,3.65,151.02,,0,0.001,89.403,0.058,0.017,0.029,1532.416,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-05",3,1.21,42,,0,0.001,24.778,0.0583,0.009,0.022,424.598,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-06",4,3.34,129.52,,0,0.001,81.264,0.058,0.014,0.0225,1394.342,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-07",5,3.94,169.81,,0.001,0.001,98.435,0.058,0.015,0.015,1686.396,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-08",3,1.65,55.6,,0,0.001,39.05,0.058,0.01,0.037,669.315,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-15",2,1.37,33.24,,0,0.001,29.871,0.058,0.01,0.0395,512.7,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-19",7,4.24,90.15,,0,0.0009,66.147,0.0584,0.017,0.016,1133.987,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-21",8,6.27,157.1,,0.001,0.001,110.742,0.058,0.022,0.0174,1899.544,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-23",2,1.05,20.93,,0,0.001,21.971,0.058,0.009,0.0665,376.621,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-03",3,1.19,43.2,,0,0.001,27.056,0.0583,0.01,0.024,464.116,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-05",9,7.57,278.26,,0.001,0.001,171.479,0.058,0.028,0.0226,2941.108,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-06",12,11.34,438.25,,0.001,0.001,258.08,0.058,0.036,0.0161,4423.599,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-23",6,5.2,170.44,,0.001,0.001,107.096,0.0582,0.014,0.023,1835.878,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-21",3,1.53,30.09,,0,0.001,24.461,0.06,0.015,0.105,401.397,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"13",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-08",3,1.9,43.35,,0,0.001,31.305,0.0597,0.009,0.0263,522.35,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-15",5,4.03,168.43,,0.001,0.001,102.034,0.058,0.02,0.0238,1746.648,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-03",6,4.44,189.56,,0.001,0.0008,112.608,0.058,0.023,0.0205,1929.15,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-04",11,7.63,279.41,,0.001,0.001,182.227,0.0581,0.039,0.036,3123.773,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-09",8,7.12,326,,0.001,0.001,184.472,0.058,0.033,0.0216,3160.62,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-10",5,3.04,125.32,,0,0.001,75.172,0.0582,0.02,0.025,1288.262,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-11",15,13.82,609,,0.002,0.0009,346.758,0.0581,0.061,0.0201,5941.034,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-12",3,2.37,88.67,,0,0.001,58.219,0.058,0.016,0.0317,997.512,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-14",14,13.34,517.16,,0.002,0.001,308.725,0.058,0.047,0.021,5293.132,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-17",3,1.28,48,,0,0.001,30.153,0.058,0.008,0.0363,517.271,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-11",4,2,31.89,,0,0.001,29.446,0.0595,0.014,0.0353,487.257,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-17",3,1.53,52.89,,0,0.001,36.623,0.058,0.008,0.0307,627.021,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-15",2,1.67,32.04,,0,0.001,28.426,0.061,0.014,0.0565,470.571,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-01",2,0.51,0,,0,0.001,2.981,0.059,0.002,0.081,50.797,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-27",7,5.85,255.35,,0.001,0.001,151.468,0.058,0.032,0.027,2596.084,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-28",15,13.57,617.78,,0.002,0.001,360.414,0.058,0.044,0.0147,6179.122,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-10",2,0.43,1.66,,0,0.001,6.438,0.058,0.004,0.072,110.489,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-15",4,2.25,94.4,,0,0.001,56.76,0.0583,0.007,0.0203,973.2,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-16",2,1.63,54.92,,0,0.001,39.239,0.058,0.011,0.034,672.513,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-18",3,1.8,31.38,,0,0.001,30.432,0.06,0.017,0.052,500.042,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-02",4,1.95,49.57,,0,0.001,43.573,0.058,0.015,0.033,746.968,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-06",8,7.1,322.71,,0.001,0.001,186.574,0.058,0.021,0.0143,3197.562,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-07",4,2.35,94.95,,0,0.001,58.45,0.058,0.009,0.0235,1003.355,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-20",17,15.68,650.29,,0.002,0.001,384.3,0.058,0.04,0.0141,6588.384,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-01",2,0.73,8.62,,0,0.001,14.932,0.058,0.007,0.059,256.018,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-03",5,4.6,195.5,,0.001,0.001,118.223,0.058,0.019,0.0194,2025.801,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-14",6,5.12,216.2,,0.001,0.001,131.13,0.058,0.018,0.0173,2248.548,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-15",8,6.73,295.56,,0.001,0.001,175.312,0.0581,0.018,0.0144,3004.195,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-17",4,3.24,133.96,,0,0.001,81.948,0.058,0.008,0.023,1402.732,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-18",8,6.85,281.99,,0.001,0.001,170.721,0.058,0.021,0.0183,2926.117,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-19",5,3.98,167.48,,0.001,0.001,101.459,0.058,0.014,0.017,1739.692,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-20",6,5.15,215.55,,0.001,0.001,133.36,0.058,0.015,0.0192,2285.23,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-23",6,5.18,225.22,,0.001,0.001,134.376,0.058,0.015,0.0135,2301.791,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-24",7,5.66,246.5,,0.001,0.001,146.858,0.058,0.015,0.0119,2515.002,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-28",4,2.54,98,,0,0.001,63.29,0.058,0.012,0.031,1085.024,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-08-31",3,1.61,32.33,,0,0.001,27.461,0.059,0.009,0.0373,455.629,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-05",7,5.56,240.19,,0.001,0.0009,142.817,0.058,0.019,0.014,2449.28,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-06",6,4.92,205.3,,0.001,0.001,121.904,0.0582,0.014,0.0125,2087.754,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-14",7,6.05,272.02,,0.001,0.001,155.487,0.0581,0.023,0.0166,2664.224,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-16",5,3.73,151.41,,0,0.001,93.709,0.058,0.015,0.027,1605.013,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-17",4,3.05,131.31,,0,0.001,75.501,0.0583,0.014,0.0195,1294.908,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-18",6,3.78,134.08,,0,0.001,90.865,0.058,0.014,0.0155,1556.846,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-20",6,4.97,212.19,,0.001,0.001,125.16,0.058,0.055,0.0543,2145.588,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-01",2,1.51,32.58,,0,0.001,25.258,0.0615,0.009,0.0425,419.738,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-02",2,1.05,25.66,,0,0.001,20.506,0.058,0.008,0.032,351.417,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-05",2,1.1,42,,0,0.001,24.44,0.058,0.007,0.023,418.07,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-06",4,3.3,129.3,,0,0.001,82.75,0.058,0.01,0.015,1418.29,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-07",4,3.88,169.16,,0.001,0.001,99.15,0.058,0.013,0.0155,1701.164,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-08",3,1.63,54.95,,0,0.001,39.193,0.058,0.008,0.0293,672.266,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-15",2,0.95,14.29,,0,0.001,18.073,0.058,0.007,0.0465,309.98,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-20",8,6.52,223.86,,0.001,0.001,143.666,0.058,0.011,0.0139,2462.894,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-03",3,1.18,45.23,,0,0.001,27.766,0.058,0.008,0.0273,475.594,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-23",3,1.86,45.11,,0,0.001,32.821,0.061,0.01,0.0317,544.397,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Harbor Generating Station",399,"14",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-06",18,17.62,142,,0.001,0.001,241.026,0.0582,0.024,0.0129,4129.61,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-07",24,24,2241,,0.007,0.001,1395.8,0.058,0.024,0.0015,23924.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-08",24,24,1745,,0.006,0.001,1104.5,0.058,0.032,0.0029,18932.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-09",24,23.74,1620.16,,0.006,0.001,1103.498,0.058,0.017,0.0013,18915.97,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-10",3,2.77,117.71,,0,0.001,94.612,0.058,0,0.0003,1622.007,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-15",11,10.72,0,,0,0.001,75.484,0.0584,0.012,0.018,1291.86,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-16",24,24,929,,0.004,0.001,740.7,0.0581,0.018,0.0029,12695.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-17",24,24,1122,,0.004,0.001,837.9,0.058,0.016,0.0023,14360.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-18",24,24,1234,,0.005,0.001,898.6,0.058,0.015,0.002,15401.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-19",24,24,1473,,0.005,0.001,1008.6,0.058,0.01,0.001,17291.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-20",24,23,1108.02,,0.004,0.001,844.14,0.058,0.007,0.001,14466.522,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-21",24,24,2473,,0.008,0.001,1532.8,0.058,0.05,0.0027,26271.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-22",24,24,1619,,0.006,0.001,1069.9,0.058,0.018,0.0015,18338,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-23",24,24,1271,,0.005,0.001,880.4,0.058,0.005,0.0005,15096,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-24",24,23.95,1734.3,,0.006,0.001,1110.485,0.058,0.037,0.0042,19034.69,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-25",24,24,1533,,0.005,0.001,1010.7,0.058,0.007,0.0008,17320.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-26",24,24,1882,,0.006,0.001,1223.4,0.058,0.014,0.0008,20964.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-27",24,24,2052,,0.007,0.001,1296.5,0.058,0.016,0.0008,22218.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-28",24,24,1953,,0.006,0.001,1255.2,0.058,0.017,0.0008,21517.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-29",24,24,1194,,0.004,0.001,857.3,0.058,0,0,14693.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-04-30",24,24,1274,,0.005,0.001,895.9,0.058,0,0,15357.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-01",21,20.97,1219.13,,0.004,0.001,843.692,0.058,0.004,0.0003,14460.947,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-10",3,2.38,0,,0,0.001,17.212,0.058,0,0.0027,295.822,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-11",24,24,855,,0.004,0.001,689.1,0.0582,0.253,0.033,11810.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-12",24,23.98,1625.98,,0.006,0.001,1098.442,0.058,0.068,0.0057,18825.018,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-13",24,24,1575,,0.005,0.001,1026.1,0.058,0.004,0.0004,17582.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-14",8,7.36,352.56,,0.001,0.001,254.086,0.058,0,0,4353.178,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-13",8,6.94,0,,0,0.001,48.611,0.0585,0.007,0.0141,832.981,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-14",6,3.82,0,,0,0.001,30.022,0.0583,0.001,0.002,513.964,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-15",2,1.75,0,,0,0.001,12.327,0.058,0,0.002,210.784,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-16",14,12.46,0,,0,0.001,74.754,0.0584,0.012,0.018,1280.489,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-17",3,2.03,0,,0,0.001,12.913,0.058,0,0.0027,221.648,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-18",24,24,1381,,0.005,0.001,943.2,0.058,0.012,0.0058,16163.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-19",24,24,1658,,0.006,0.001,1081.4,0.058,0,0,18533.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-20",24,24,1441,,0.005,0.001,1002.2,0.058,0.001,0,17177.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-21",24,24,1718,,0.006,0.001,1136.7,0.058,0.003,0.0003,19481.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-22",24,24,1792,,0.006,0.001,1174.3,0.058,0.002,0.0001,20126.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-23",24,24,2089,,0.007,0.001,1363.4,0.058,0.017,0.001,23369.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-24",24,24,1237,,0.005,0.001,876.6,0.058,0,0,15026.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-25",24,24,1218,,0.005,0.001,921.8,0.058,0,0,15802.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-26",24,23.93,1308.5,,0.005,0.001,958.616,0.058,0,0,16432.417,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-27",24,24,1411,,0.005,0.001,950.2,0.058,0,0,16286.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-28",24,24,1235,,0.004,0.001,857.5,0.058,0,0,14696.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-29",24,23.98,1213,,0.004,0.001,845.994,0.058,0,0,14496.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-30",21,20.05,996.05,,0.004,0.001,700.535,0.058,0,0,12005.085,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-01",3,2.32,0,,0,0.001,18.876,0.0587,0,0.0013,323.384,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-02",2,1.05,0,,0,0.001,7.07,0.058,0,0.001,121.051,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-03",17,15.8,459,,0.002,0.001,397.473,0.0581,0.013,0.0029,6811.594,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-04",24,24,1691,,0.006,0.001,1079.8,0.058,0.007,0.0009,18504.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-05",24,24,2126,,0.007,0.001,1316.5,0.058,0.027,0.0011,22565.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-06",24,24,2529,,0.008,0.001,1543.1,0.058,0.028,0.0013,26450.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-07",24,24,1321,,0.005,0.001,895.8,0.058,0,0,15353.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-08",24,24,1178,,0.004,0.001,808.2,0.058,0,0,13858.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-09",18,17.95,1218.15,,0.004,0.001,788.255,0.058,0.004,0.0003,13506.93,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-11",7,5.6,0,,0,0.001,38.435,0.0583,0,0.0011,657.543,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-12",24,24,1194,,0.004,0.001,870.7,0.058,0.006,0.0007,14926,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-13",24,24,1663,,0.006,0.001,1083.2,0.058,0.002,0.0001,18566.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-14",24,24,2110,,0.007,0.001,1319.5,0.058,0.02,0.001,22614.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-15",24,24,2262,,0.007,0.001,1383.5,0.058,0.012,0.0007,23707.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-16",24,24,2174,,0.007,0.001,1352.4,0.058,0.011,0.0005,23181.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-17",24,24,2145,,0.007,0.001,1339.5,0.058,0.017,0.0008,22960.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-18",24,24,3017,,0.009,0.001,1796.3,0.058,0.018,0.0009,30788,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-19",24,24,2207,,0.007,0.001,1360.2,0.058,0.01,0.0005,23316.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-20",24,24,2239,,0.007,0.001,1383.2,0.058,0.016,0.0008,23709,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-21",24,24,1842,,0.006,0.001,1150.7,0.058,0.008,0.0005,19719.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-22",24,24,2294,,0.007,0.001,1399,0.058,0.009,0.0004,23979.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-23",24,23.95,2117.95,,0.007,0.001,1307.835,0.058,0.014,0.0008,22418.98,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-24",24,24,1761,,0.006,0.001,1111.4,0.058,0.002,0.0002,19053.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-25",24,24,1596,,0.005,0.001,1026.3,0.058,0,0,17587.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-26",24,24,1421,,0.005,0.001,938.3,0.058,0,0,16083.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-27",24,24,1395,,0.005,0.001,932.5,0.058,0,0,15981.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-28",24,24,1622,,0.005,0.001,1029.8,0.058,0,0,17653.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-29",24,24,1836,,0.006,0.001,1146.6,0.058,0.002,0.0001,19652.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-09-30",24,23.87,1792.24,,0.006,0.001,1124.504,0.058,0.006,0.0003,19274.666,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-01",24,24,1678,,0.005,0.001,1053.8,0.058,0.001,0.0001,18063.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-02",24,24,1886,,0.006,0.001,1177.7,0.058,0.003,0.0003,20188.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-03",24,24,2029,,0.006,0.001,1258.4,0.058,0.005,0.0003,21570.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-04",24,24,1766,,0.006,0.001,1115.4,0.058,0.01,0.0005,19117.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-05",24,24,2299,,0.007,0.001,1402.3,0.058,0.03,0.0022,24037.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-06",20,19.47,1594.92,,0.005,0.001,1005.732,0.058,0.007,0.0005,17238.793,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-14",1,0.03,0,,0,0.001,1.314,0.058,0,0,22.524,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-15",4,0.52,0,,0,0.001,53.38,0.058,0,0.001,914.994,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-22",1,0.02,0,,0,0.001,0.07,0.059,0,0.001,1.184,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-02",15,13.95,161,,0.001,0.0009,206.087,0.0582,0.017,0.0141,3532.056,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-03",24,24,1492,,0.005,0.001,963.9,0.058,0.017,0.001,16521.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-04",24,24,1307,,0.004,0.001,867.2,0.058,0.002,0.0002,14867.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-05",19,18.77,1186.77,,0.004,0.001,766.129,0.058,0.003,0.0003,13132.982,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-09",2,0.21,0,,0,0.001,0.929,0.059,0,0,15.785,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-10",1,0.02,0,,0,0.001,0.096,0.058,0,0.001,1.652,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-01",24,24,5557,,0.012,0.001,2254.9,0.058,0.116,0.006,38645.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-02",19,18.42,4211.14,,0.009,0.001,1701.27,0.058,0.113,0.0107,29160.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-03",24,24,5683,,0.012,0.001,2290.7,0.058,0.117,0.006,39264.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-04",19,18.34,4386.31,,0.009,0.001,1781.987,0.058,0.113,0.0102,30545.389,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-05",24,24,5545,,0.012,0.001,2258.5,0.058,0.116,0.006,38706.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-06",11,9.55,2203.86,,0.005,0.001,905.182,0.058,0.083,0.016,15515.251,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-07",24,24,5619,,0.012,0.001,2292.9,0.058,0.118,0.006,39299.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-08",20,19,4526.96,,0.009,0.001,1824.04,0.058,0.112,0.0082,31260.996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-09",24,24,5706,,0.012,0.001,2314.8,0.058,0.119,0.006,39675.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-10",24,24,5614,,0.012,0.001,2299.3,0.058,0.118,0.006,39407.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-11",20,19.22,4706.36,,0.01,0.001,1906.656,0.058,0.119,0.0106,32682.518,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-12",24,24,5806,,0.012,0.001,2342.3,0.058,0.12,0.006,40146.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-13",24,24,6002,,0.012,0.001,2414,0.058,0.122,0.0059,41373.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-14",24,24,5781,,0.012,0.001,2343,0.058,0.119,0.0059,40161.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-15",24,24,6440,,0.013,0.001,2574,0.058,0.131,0.006,44115.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-16",24,24,6509,,0.013,0.001,2608.3,0.058,0.134,0.006,44708.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-17",24,24,6224,,0.013,0.001,2475.8,0.058,0.126,0.006,42433,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-18",24,24,5979,,0.012,0.001,2397.2,0.058,0.123,0.006,41086.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-19",23,21.81,5312.92,,0.011,0.001,2151.788,0.058,0.126,0.0083,36885.351,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-20",24,24,6226,,0.013,0.001,2473.7,0.058,0.127,0.006,42397.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-21",24,24,6220,,0.013,0.001,2471.3,0.058,0.126,0.006,42355.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-22",24,24,6085,,0.013,0.001,2431.2,0.058,0.124,0.006,41667.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-23",24,24,6090,,0.013,0.001,2433.5,0.058,0.125,0.006,41707.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-24",20,18.85,4592.85,,0.01,0.001,1859.625,0.058,0.112,0.0099,31879.155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-25",24,24,5584,,0.012,0.001,2279.5,0.058,0.115,0.0059,39070.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-26",21,19.39,4652.2,,0.01,0.001,1887.36,0.058,0.117,0.0081,32350.289,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-27",24,23.98,6042.86,,0.012,0.001,2427.874,0.058,0.124,0.006,41616.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-28",21,19.26,4660.7,,0.01,0.001,1885.308,0.058,0.115,0.0078,32309.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-29",24,24,5746,,0.012,0.001,2328.9,0.058,0.12,0.006,39916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-30",22,20.81,5018.34,,0.01,0.001,2038.003,0.058,0.117,0.0081,34931.324,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-01-31",24,24,6090,,0.013,0.001,2458,0.058,0.126,0.006,42133.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-01",24,24,5721,,0.012,0.001,2295.7,0.058,0.116,0.0059,39348.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-02",17,15.47,3696.55,,0.008,0.0009,1500.897,0.0581,0.098,0.0109,25727.213,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-03",24,24,5984,,0.012,0.001,2428.3,0.058,0.125,0.006,41621.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-04",24,24,6107,,0.013,0.001,2466.8,0.058,0.127,0.006,42282.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-05",24,24,5994,,0.012,0.001,2395.5,0.058,0.123,0.006,41056.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-06",20,19.45,4744.12,,0.01,0.001,1922.422,0.058,0.115,0.0093,32951.065,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-07",24,24,6191,,0.013,0.001,2479.7,0.058,0.127,0.006,42500.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-08",24,24,5546,,0.012,0.001,2264.7,0.058,0.115,0.0059,38811.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-09",24,24,6163,,0.013,0.001,2499.7,0.058,0.128,0.006,42845.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-10",24,23.82,6325.44,,0.013,0.001,2586.174,0.058,0.133,0.006,44326.007,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-11",24,24,6236,,0.013,0.001,2513.1,0.058,0.129,0.006,43073.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-12",21,19.53,4832.45,,0.01,0.001,1989.706,0.058,0.116,0.0072,34100.695,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-13",24,24,6162,,0.013,0.001,2489.5,0.058,0.127,0.006,42675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-14",24,24,5747,,0.012,0.001,2335.3,0.058,0.119,0.006,40027.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-15",22,20.54,4864.92,,0.01,0.001,1977.582,0.058,0.116,0.0089,33896.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-16",24,24,5649,,0.012,0.001,2304.3,0.058,0.117,0.0059,39495.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-17",24,24,5879,,0.012,0.001,2378.3,0.058,0.122,0.006,40761.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-18",24,24,5956,,0.012,0.001,2427.3,0.058,0.124,0.006,41603,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-19",24,24,5753,,0.012,0.001,2323.4,0.058,0.119,0.006,39821.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-20",24,23.98,5680.86,,0.012,0.001,2296.404,0.058,0.118,0.006,39360.782,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-21",24,23.98,5661.42,,0.012,0.001,2286.282,0.058,0.116,0.0059,39187.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-22",24,24,6036,,0.012,0.001,2414.7,0.058,0.123,0.006,41385.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-23",24,24,5332,,0.011,0.001,2203.2,0.058,0.113,0.006,37763.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-24",24,24,6043,,0.013,0.001,2447.9,0.058,0.126,0.006,41957.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-25",24,24,6132,,0.013,0.001,2478,0.058,0.127,0.006,42473.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-26",24,24,5997,,0.012,0.001,2398.2,0.058,0.123,0.006,41106.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-27",20,19.2,4709.3,,0.01,0.001,1904.64,0.058,0.118,0.009,32644.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-28",24,24,6287,,0.013,0.001,2531.2,0.058,0.13,0.006,43381,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-02-29",24,24,5182,,0.011,0.001,2124,0.058,0.109,0.006,36406.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-01",24,24,5003,,0.011,0.001,2099.2,0.058,0.106,0.0059,35980,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-02",20,19.33,3595.56,,0.008,0.001,1548.973,0.058,0.081,0.0066,26552.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-03",20,19.18,3937.52,,0.009,0.001,1772.144,0.058,0.131,0.0117,30375.354,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-04",24,24,5679,,0.012,0.001,2361.6,0.058,0.121,0.006,40478.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-05",24,24,5748,,0.012,0.001,2386.1,0.058,0.121,0.0059,40898.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-06",24,24,5943,,0.013,0.001,2450.5,0.058,0.126,0.006,42004.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-07",20,19.73,4824.09,,0.01,0.001,1976.183,0.058,0.12,0.0088,33868.791,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-08",22,21.33,4693.21,,0.01,0.001,1960.664,0.058,0.101,0.0064,33605.564,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-10",6,5.93,1274.2,,0.003,0.001,535.096,0.058,0.07,0.029,9171.826,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-11",24,24,5521,,0.012,0.001,2248.5,0.058,0.116,0.006,38534.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-12",24,24,6054,,0.012,0.001,2427.8,0.058,0.124,0.006,41612.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-13",24,24,6048,,0.013,0.001,2442.5,0.058,0.126,0.006,41861.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-14",24,23.9,5366,,0.011,0.001,2206.978,0.058,0.113,0.006,37826.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-15",17,15.73,3642.32,,0.008,0.001,1501.434,0.058,0.098,0.0084,25734.812,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-16",24,24,6324,,0.013,0.001,2553.2,0.058,0.13,0.006,43761.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-17",24,24,5784,,0.012,0.001,2379.9,0.058,0.121,0.0059,40791.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-18",24,24,5906,,0.012,0.001,2392.3,0.058,0.121,0.0059,41004.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-19",24,24,5880,,0.012,0.001,2398.1,0.058,0.123,0.006,41103.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-20",18,16.44,4193.25,,0.009,0.001,1716.08,0.058,0.105,0.0102,29411.339,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-21",19,18.16,4553.02,,0.01,0.001,1858.722,0.058,0.108,0.008,31858.252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-22",16,15.32,3793.76,,0.008,0.001,1566.962,0.058,0.109,0.012,26860.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-23",9,8.42,2080.42,,0.004,0.001,851.284,0.058,0.044,0.0068,14588.726,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-24",9,8.03,1685,,0.004,0.001,707.582,0.0581,0.08,0.0183,12128.218,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-25",8,7.55,1839.8,,0.004,0.001,756.015,0.058,0.044,0.008,12956.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-03-31",3,1.71,30.05,,0,0.001,57.5,0.058,0.046,0.093,985.099,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-02",13,11.29,1778.82,,0.004,0.001,858.967,0.058,0.132,0.0396,14723.995,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-03",7,6.77,1595.22,,0.003,0.001,679.418,0.058,0.037,0.0066,11644.674,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-04",7,6.57,1232.56,,0.003,0.001,556.212,0.058,0.088,0.043,9534.611,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-05",19,17.42,3952.66,,0.009,0.001,1671.846,0.058,0.126,0.0122,28654.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-06",24,24,5441,,0.012,0.001,2281.2,0.058,0.116,0.006,39098.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-07",20,18.48,4179.55,,0.009,0.001,1773.38,0.058,0.124,0.0099,30393.605,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-08",24,24,6053,,0.013,0.001,2473.8,0.058,0.126,0.006,42399.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-09",24,23.72,6299.88,,0.013,0.001,2552.639,0.058,0.13,0.006,43753.334,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-10",24,23.98,6121.76,,0.013,0.001,2462.258,0.058,0.127,0.006,42205.094,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-11",24,24,5555,,0.012,0.001,2279.1,0.058,0.117,0.006,39062.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-12",16,14.87,3365.42,,0.007,0.001,1408.176,0.058,0.102,0.0144,24137.213,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-13",17,15.57,3409.57,,0.007,0.001,1458.244,0.058,0.099,0.0131,24993.785,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-14",7,6.03,1084,,0.002,0.001,475.91,0.058,0.026,0.0057,8157.491,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-15",10,9.03,1763,,0.004,0.001,776.567,0.058,0.088,0.0194,13309.187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-16",8,7.08,1521,,0.003,0.001,641.988,0.058,0.034,0.0058,11003.172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-19",11,10.9,2034.3,,0.005,0.001,911.68,0.058,0.131,0.0319,15627.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-20",24,24,5525,,0.012,0.001,2279.7,0.058,0.116,0.006,39069.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-21",8,7.6,1760.8,,0.004,0.001,722.86,0.058,0.04,0.0071,12390.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-23",12,11.93,2084.58,,0.005,0.001,930.349,0.058,0.098,0.0213,15948.09,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-24",24,23.95,5660.75,,0.012,0.001,2318.795,0.058,0.119,0.006,39747.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-25",24,24,5759,,0.012,0.001,2328.7,0.058,0.119,0.006,39915.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-26",24,24,5573,,0.012,0.001,2298.3,0.058,0.117,0.006,39391.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-27",24,24,5593,,0.012,0.001,2302.8,0.058,0.117,0.0059,39467.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-28",24,24,5372,,0.011,0.001,2235.9,0.058,0.113,0.0059,38319,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-29",24,24,5535,,0.011,0.001,2236.1,0.058,0.112,0.0059,38325.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-04-30",24,24,4650,,0.01,0.001,1974.7,0.058,0.101,0.006,33849.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-01",24,24,5549,,0.012,0.001,2260.1,0.058,0.115,0.006,38739.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-02",16,14.29,2948.94,,0.006,0.001,1253.547,0.058,0.098,0.0117,21486.582,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-03",10,9.18,1752,,0.004,0.001,771.308,0.058,0.078,0.0169,13219.566,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-04",24,24,5297,,0.011,0.001,2190.6,0.058,0.111,0.0059,37549.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-05",24,23.95,5739.45,,0.012,0.001,2374.44,0.058,0.121,0.0059,40696.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-06",24,24,5691,,0.012,0.001,2321.4,0.058,0.117,0.0059,39786.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-07",24,24,5421,,0.011,0.001,2233.6,0.058,0.114,0.006,38283.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-08",24,23.97,5886.95,,0.012,0.001,2423.348,0.058,0.124,0.006,41534.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-09",22,20.99,4857,,0.01,0.001,2024.242,0.058,0.12,0.0087,34693.373,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-10",7,6.78,1453.14,,0.003,0.001,603.932,0.058,0.032,0.0064,10348.618,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-14",14,13.77,2716.77,,0.006,0.001,1204.013,0.058,0.132,0.0247,20636.385,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-15",24,24,5741,,0.012,0.001,2322.6,0.058,0.118,0.0059,39809.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-16",16,15.5,3155,,0.007,0.001,1355.25,0.058,0.102,0.0138,23225.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-17",7,6.67,1384.96,,0.003,0.001,579.871,0.058,0.032,0.0067,9939.304,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-20",18,17.97,3466.4,,0.008,0.001,1513.55,0.058,0.152,0.0196,25941.827,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-21",24,24,5706,,0.012,0.001,2355.6,0.058,0.119,0.0059,40374.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-22",24,24,5130,,0.011,0.001,2135.7,0.058,0.109,0.006,36609.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-23",18,16.91,3769.79,,0.008,0.001,1596.311,0.058,0.106,0.0116,27362.717,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-24",24,24,5295,,0.011,0.001,2199.1,0.058,0.113,0.006,37691.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-25",24,24,5498,,0.012,0.001,2274.3,0.058,0.116,0.006,38979.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-26",24,24,5784,,0.012,0.001,2386.6,0.058,0.121,0.0059,40904.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-27",24,24,5837,,0.012,0.001,2398.1,0.058,0.123,0.006,41103.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-28",24,23.97,5772.6,,0.012,0.001,2378.336,0.058,0.121,0.0059,40769.179,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-29",24,23.98,5787.52,,0.012,0.001,2345.136,0.058,0.12,0.006,40195.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-30",18,17.73,3774.27,,0.008,0.001,1581.733,0.058,0.083,0.0063,27110.039,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-05",15,13.48,2278,,0.005,0.001,1037.162,0.058,0.19,0.0393,17778.091,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-06",7,6.7,1476.6,,0.003,0.001,624.63,0.058,0.034,0.0067,10705.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-08",12,11.92,2422.64,,0.005,0.001,1060.464,0.058,0.141,0.029,18176.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-09",24,24,5967,,0.012,0.001,2422.2,0.058,0.125,0.006,41512.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-10",9,6.57,1309.17,,0.003,0.001,555.726,0.058,0.044,0.0204,9526.196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-11",24,24,5686,,0.012,0.001,2336.1,0.058,0.119,0.006,40041.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-12",24,24,5869,,0.012,0.001,2370.4,0.058,0.12,0.0059,40627.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-13",21,19.47,4205.55,,0.009,0.001,1753.997,0.058,0.104,0.0089,30065.384,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-14",17,15.57,3339.35,,0.007,0.001,1407.644,0.058,0.098,0.0124,24128.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-15",24,24,5480,,0.012,0.001,2252.8,0.058,0.113,0.0058,38607.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-16",24,24,5647,,0.012,0.001,2307.2,0.058,0.114,0.0058,39543.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-17",24,24,5511,,0.012,0.001,2251.7,0.058,0.113,0.0058,38596.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-18",24,24,5392,,0.011,0.001,2200.4,0.058,0.112,0.0059,37715.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-19",24,24,5278,,0.011,0.001,2168,0.058,0.111,0.006,37163.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-20",20,19.22,3898.98,,0.009,0.001,1674.952,0.058,0.105,0.0098,28705.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-21",16,15.48,3140.23,,0.007,0.001,1346.251,0.058,0.095,0.011,23076.344,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-22",24,23.82,5723.22,,0.012,0.001,2397.69,0.058,0.123,0.006,41098.218,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-23",14,13.1,3144.1,,0.007,0.001,1304.33,0.058,0.086,0.0087,22358.17,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-24",12,10.75,2355.55,,0.005,0.001,977.98,0.058,0.074,0.0143,16762.045,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-25",19,18.63,4258.46,,0.009,0.001,1776.491,0.058,0.106,0.0082,30449.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-26",24,24,5836,,0.012,0.001,2357.4,0.058,0.12,0.0059,40407.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-27",20,18.74,4186.46,,0.009,0.001,1725.491,0.058,0.101,0.0086,29576.579,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-28",7,6.48,1279.28,,0.003,0.001,543.22,0.058,0.028,0.0066,9309.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-01",10,9.3,1577.9,,0.004,0.001,717.44,0.058,0.099,0.0306,12296.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-02",24,24,5503,,0.012,0.001,2276.9,0.058,0.116,0.006,39027.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-03",23,22.65,5250.8,,0.011,0.001,2179.07,0.058,0.112,0.0061,37349.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-04",9,7.94,1612.44,,0.004,0.001,689.474,0.058,0.06,0.0192,11817.178,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-05",12,11.04,2528.36,,0.005,0.001,1062.894,0.058,0.077,0.0113,18216.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-06",15,14.11,2949.04,,0.007,0.001,1282.009,0.058,0.089,0.011,21971.497,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-07",16,14.94,3332.4,,0.007,0.001,1379.288,0.058,0.093,0.0118,23641.058,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-08",15,14.03,3160.93,,0.007,0.001,1305.113,0.0581,0.087,0.0089,22372.762,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-09",15,13.81,3102.92,,0.007,0.001,1310.669,0.0581,0.089,0.0091,22465.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-10",14,13.97,3458.41,,0.007,0.001,1447.806,0.058,0.091,0.0098,24817.113,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-11",24,24,5601,,0.012,0.001,2336.2,0.058,0.119,0.006,40044.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-12",24,23.98,5882.06,,0.012,0.001,2429.96,0.058,0.125,0.006,41648.148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-13",24,24,5556,,0.012,0.001,2291.7,0.058,0.114,0.0058,39285.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-14",19,18.49,4192.97,,0.009,0.001,1752.377,0.058,0.104,0.0092,30033.719,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-15",18,17.4,3846.48,,0.008,0.001,1602.66,0.058,0.099,0.0092,27468.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-16",24,24,5231,,0.011,0.001,2179.3,0.058,0.11,0.0059,37354.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-17",24,24,5574,,0.012,0.001,2309.1,0.058,0.117,0.0059,39579.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-18",15,14,3284.9,,0.007,0.001,1370.775,0.058,0.089,0.0125,23494.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-19",24,24,5624,,0.012,0.001,2299.9,0.058,0.117,0.0059,39418.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-20",14,13.92,3336.76,,0.007,0.001,1375.452,0.058,0.089,0.0095,23572.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-21",24,24,6081,,0.013,0.001,2468.8,0.058,0.125,0.0059,42314,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-22",24,24,5612,,0.011,0.001,2235.9,0.058,0.113,0.0059,38327,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-23",24,24,5874,,0.012,0.001,2331.3,0.058,0.118,0.0059,39958.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-24",24,24,5595,,0.012,0.001,2243,0.058,0.115,0.006,38441.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-25",24,24,5319,,0.011,0.001,2165.7,0.058,0.11,0.0059,37119.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-26",14,13.42,3013.14,,0.007,0.001,1271.312,0.058,0.095,0.0151,21789.658,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-27",24,24,6062,,0.013,0.001,2464.3,0.058,0.125,0.0059,42239.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-28",24,24,5518,,0.012,0.001,2257.5,0.058,0.113,0.0058,38692.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-29",24,24,5593,,0.012,0.001,2242.3,0.058,0.113,0.0059,38431.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-30",24,24,5521,,0.012,0.001,2245.1,0.058,0.115,0.006,38485.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-07-31",18,16.08,3783.19,,0.008,0.001,1580.098,0.058,0.099,0.0086,27083.049,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-01",14,13.05,3157,,0.007,0.001,1298.365,0.0581,0.084,0.0086,22253.845,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-02",17,16.17,3732.56,,0.008,0.001,1538.988,0.058,0.093,0.0096,26376.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-03",18,17.07,4047.04,,0.009,0.001,1667.41,0.058,0.1,0.0098,28581.917,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-04",24,24,5931,,0.012,0.001,2361.5,0.058,0.121,0.006,40479,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-05",23,22.67,5435,,0.011,0.001,2217.047,0.058,0.115,0.0061,37999.993,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-06",10,9.88,2004.84,,0.004,0.001,837.788,0.058,0.069,0.0149,14359.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-07",24,23.23,5239.14,,0.011,0.001,2123.278,0.058,0.109,0.0062,36392.084,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-08",11,10.78,2423.2,,0.005,0.001,991.798,0.058,0.069,0.0119,17001.244,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-09",24,24,5521,,0.011,0.001,2233.9,0.058,0.114,0.006,38290.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-10",24,24,5662,,0.012,0.001,2304.1,0.058,0.118,0.006,39493.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-11",14,13.68,3175.31,,0.007,0.001,1296.957,0.058,0.082,0.0106,22229.761,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-12",24,24,5624,,0.012,0.001,2286.8,0.058,0.118,0.006,39196.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-13",24,24,5845,,0.012,0.001,2331,0.058,0.118,0.0059,39952.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-14",24,24,6130,,0.013,0.001,2475.6,0.058,0.127,0.006,42431.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-15",24,24,5687,,0.012,0.001,2314.6,0.058,0.118,0.0059,39670.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-16",24,24,5257,,0.011,0.001,2170.1,0.058,0.111,0.006,37194.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-17",23,22.25,4870.75,,0.01,0.001,2024.725,0.058,0.105,0.0062,34702,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-18",20,19.68,4472.44,,0.01,0.001,1882.948,0.058,0.129,0.011,32277.464,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-19",24,24,5208,,0.011,0.001,2162.1,0.058,0.11,0.006,37056.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-20",24,24,4951,,0.01,0.001,2034.4,0.058,0.103,0.0059,34865,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-21",24,24,5342,,0.011,0.001,2165.6,0.058,0.111,0.006,37115,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-22",24,24,5711,,0.012,0.001,2299.2,0.058,0.118,0.006,39402.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-23",24,24,5724,,0.012,0.001,2307.7,0.058,0.119,0.006,39556.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-24",24,24,5761,,0.012,0.001,2321.7,0.058,0.119,0.006,39790.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-25",24,24,5671,,0.012,0.001,2282.9,0.058,0.117,0.006,39127.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-26",24,23.93,5408.2,,0.011,0.001,2192.855,0.058,0.112,0.006,37585.471,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-27",24,24,5249,,0.011,0.001,2127.4,0.058,0.109,0.006,36461.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-28",24,24,5347,,0.011,0.001,2164.4,0.058,0.111,0.006,37094.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-29",24,23.98,4985.06,,0.01,0.001,2040.69,0.058,0.105,0.006,34977.852,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-30",24,24,4946,,0.01,0.001,2024.3,0.058,0.104,0.006,34699.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-08-31",24,24,5956,,0.012,0.001,2368.7,0.058,0.121,0.006,40597.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-01",24,24,5726,,0.012,0.001,2286,0.058,0.118,0.006,39180.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-02",24,24,5715,,0.012,0.001,2293,0.058,0.117,0.006,39297.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-03",24,24,5659,,0.012,0.001,2263,0.058,0.116,0.006,38790.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-04",24,24,5787,,0.012,0.001,2303.2,0.058,0.118,0.006,39475.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-05",24,24,5098,,0.011,0.001,2065.8,0.058,0.106,0.006,35407.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-06",24,24,5265,,0.011,0.001,2116.7,0.058,0.108,0.006,36280.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-07",24,24,5455,,0.011,0.001,2181.5,0.058,0.112,0.006,37387.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-08",24,24,5337,,0.011,0.001,2139.2,0.058,0.11,0.006,36669.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-09",24,24,5441,,0.011,0.001,2187.3,0.058,0.112,0.006,37495.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-10",24,24,5175,,0.011,0.001,2095,0.058,0.107,0.006,35905.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-11",24,24,5950,,0.012,0.001,2363.6,0.058,0.122,0.006,40512.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-12",24,24,5406,,0.011,0.001,2173.1,0.058,0.112,0.006,37244.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-13",24,24,5192,,0.011,0.001,2099.5,0.058,0.107,0.006,35985.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-14",24,24,5355,,0.011,0.001,2161.8,0.058,0.111,0.006,37054.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-15",24,24,5890,,0.012,0.001,2343.2,0.058,0.12,0.006,40169,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-16",24,24,5553,,0.011,0.001,2231.9,0.058,0.115,0.006,38256.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-17",22,21.78,5149.02,,0.011,0.001,2075.282,0.058,0.107,0.006,35571.568,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-21",16,15.47,2803.76,,0.006,0.001,1224.187,0.058,0.124,0.0226,20978.306,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-22",23,22.87,5018.41,,0.011,0.001,2054.521,0.058,0.106,0.006,35212.883,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-23",13,12.5,2897,,0.006,0.001,1167.8,0.058,0.078,0.0131,20017.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-24",24,24,5735,,0.012,0.001,2288.1,0.058,0.118,0.006,39220.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-25",24,24,5384,,0.011,0.001,2161.5,0.058,0.11,0.006,37043.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-26",24,23.17,5319.19,,0.011,0.001,2165.765,0.058,0.111,0.0061,37121.634,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-27",12,11.53,2568.6,,0.005,0.001,1044.384,0.058,0.074,0.0145,17902.813,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-28",24,24,5439,,0.011,0.001,2181.3,0.058,0.111,0.006,37385.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-29",24,24,5482,,0.011,0.001,2195.2,0.058,0.112,0.006,37627.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-09-30",24,23.87,5680.54,,0.012,0.001,2270.448,0.058,0.117,0.006,38916.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-01",24,24,5670,,0.012,0.001,2257,0.058,0.115,0.006,38686.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-02",24,24,5590,,0.011,0.001,2230.5,0.058,0.114,0.006,38228.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-03",24,24,5481,,0.011,0.001,2196,0.058,0.112,0.006,37642.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-04",24,24,5453,,0.011,0.001,2187.5,0.058,0.112,0.006,37492.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-05",22,21.55,4828.15,,0.01,0.001,1961.365,0.058,0.101,0.0061,33618.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-06",15,14.72,3368.48,,0.007,0.001,1365.412,0.058,0.082,0.0095,23403.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-07",24,24,5624,,0.012,0.001,2258.5,0.058,0.116,0.006,38711.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-08",22,21.17,4879.36,,0.01,0.001,1962.973,0.058,0.1,0.0061,33646.385,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-09",11,10.07,2299.07,,0.005,0.001,932.158,0.058,0.071,0.0105,15979.163,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-10",24,24,5527,,0.011,0.001,2211.2,0.058,0.113,0.006,37899.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-11",24,24,5324,,0.011,0.001,2140.4,0.058,0.108,0.0059,36685.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-12",24,24,4949,,0.01,0.001,2012.6,0.058,0.103,0.006,34495.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-13",24,24,5230,,0.011,0.001,2116.2,0.058,0.109,0.006,36273.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-14",24,24,5396,,0.011,0.001,2168.1,0.058,0.111,0.006,37157.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-15",24,24,5573,,0.012,0.001,2237.2,0.058,0.114,0.006,38342,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-16",24,24,5834,,0.012,0.001,2328,0.058,0.12,0.006,39900.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-17",24,24,5666,,0.012,0.001,2275.2,0.058,0.116,0.006,38997.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-18",24,24,5628,,0.012,0.001,2268.5,0.058,0.116,0.006,38881.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-19",24,24,5869,,0.012,0.001,2362.9,0.058,0.122,0.006,40499.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-20",24,24,5889,,0.012,0.001,2360.9,0.058,0.121,0.006,40466.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-21",24,23.63,5670.55,,0.012,0.001,2284.774,0.058,0.118,0.0061,39162.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-23",12,11.23,2240,,0.005,0.001,977.883,0.058,0.095,0.0191,16763.916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-24",24,24,5296,,0.011,0.001,2201.9,0.058,0.112,0.0059,37741.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-25",19,17.47,4103.27,,0.009,0.001,1662.498,0.058,0.1,0.0095,28490.058,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-26",22,21.42,4547,,0.01,0.001,1901.054,0.058,0.099,0.0063,32581.936,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-27",10,9.43,2127.02,,0.004,0.001,867.214,0.058,0.078,0.022,14865.201,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-28",24,23.97,5690.62,,0.012,0.001,2289.676,0.058,0.118,0.006,39246.754,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-29",24,24,5404,,0.011,0.001,2195.4,0.058,0.113,0.006,37630.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-30",24,24,5967,,0.012,0.001,2374.9,0.058,0.122,0.006,40703.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-10-31",24,24,5756,,0.012,0.001,2314.1,0.058,0.119,0.006,39667,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-01",24,24,5708,,0.012,0.001,2289.9,0.058,0.118,0.006,39251.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-02",24,24,5742,,0.012,0.001,2303.6,0.058,0.115,0.0058,39484.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-03",24,24,5941,,0.012,0.001,2377.5,0.058,0.122,0.006,40749.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-04",24,24,5507,,0.012,0.001,2258.7,0.058,0.116,0.006,38709.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-05",24,23.87,5330.52,,0.011,0.001,2182.761,0.058,0.111,0.006,37412.249,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-06",24,24,5877,,0.012,0.001,2351.3,0.058,0.121,0.006,40296.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-07",24,24,5902,,0.012,0.001,2364.2,0.058,0.122,0.006,40523.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-08",18,16.88,3912.92,,0.008,0.001,1597.575,0.0581,0.101,0.0084,27380.704,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-09",16,14.53,3482.99,,0.007,0.001,1415.266,0.058,0.093,0.012,24258.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-10",11,9.57,2149,,0.005,0.001,881.383,0.0581,0.075,0.0189,15106.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-11",24,24,5954,,0.012,0.001,2373.8,0.058,0.122,0.006,40686.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-12",24,24,6028,,0.012,0.001,2400.1,0.058,0.123,0.006,41136.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-13",24,24,5701,,0.012,0.001,2273.3,0.058,0.117,0.006,38964.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-14",24,23.85,5594.25,,0.012,0.001,2244.92,0.058,0.115,0.006,38476.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-15",17,16.04,3818.36,,0.008,0.001,1533.056,0.058,0.104,0.0084,26276.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-16",24,23.97,5972.47,,0.012,0.001,2372.107,0.058,0.122,0.006,40658.872,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-17",24,24,5657,,0.012,0.001,2277.8,0.058,0.117,0.006,39045.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-18",9,8.23,1993.91,,0.004,0.001,805.103,0.058,0.042,0.0064,13801.355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-19",10,9.75,2175,,0.005,0.001,881.375,0.058,0.077,0.0187,15106.875,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-20",24,24,6065,,0.012,0.001,2388.8,0.058,0.123,0.006,40945.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-21",24,24,5817,,0.012,0.001,2322.8,0.058,0.119,0.006,39810.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-22",24,24,5640,,0.012,0.001,2257.8,0.058,0.116,0.006,38703.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-23",24,24,6042,,0.012,0.001,2372.7,0.058,0.122,0.006,40667.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-24",24,24,5921,,0.012,0.001,2339.4,0.058,0.121,0.0061,40100.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-27",7,6.23,1140.15,,0.003,0.001,489.897,0.058,0.084,0.0324,8395.239,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-28",24,24,5477,,0.011,0.001,2212.9,0.058,0.114,0.006,37930,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-29",24,24,5808,,0.012,0.001,2325.2,0.058,0.12,0.006,39852.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-11-30",13,11.73,2663.96,,0.006,0.001,1087.36,0.058,0.079,0.0108,18637.899,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-01",24,24,5913,,0.012,0.001,2359.6,0.058,0.121,0.006,40443.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-02",11,9.8,2236.16,,0.005,0.001,900.548,0.058,0.072,0.0147,15435.628,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-03",24,24,5979,,0.012,0.001,2352,0.058,0.121,0.006,40315.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-04",23,22.73,5589.71,,0.012,0.001,2254.019,0.058,0.117,0.0061,38635.623,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-05",9,8.72,1990.76,,0.004,0.001,803.708,0.058,0.068,0.0173,13775.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-06",24,24,5630,,0.012,0.001,2238.6,0.058,0.115,0.006,38367,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-07",24,23.28,5425.56,,0.011,0.001,2151.24,0.058,0.111,0.0063,36875.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-08",11,10.2,2329,,0.005,0.001,934,0.058,0.076,0.0153,16011.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-09",24,24,5965,,0.012,0.001,2359.8,0.058,0.121,0.006,40449.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-10",11,10,2235.3,,0.005,0.001,912.39,0.058,0.077,0.0168,15639.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-11",24,24,6032,,0.012,0.001,2388.8,0.058,0.123,0.006,40948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-12",12,11.41,2506.16,,0.005,0.001,1017.43,0.058,0.076,0.0145,17442.255,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-13",24,23.77,5847.63,,0.012,0.001,2321.611,0.058,0.121,0.0061,39792.917,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-14",9,8.67,2017.11,,0.004,0.001,812.192,0.058,0.071,0.0177,13922.716,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-15",21,19.65,4446.17,,0.009,0.001,1808.491,0.0581,0.119,0.0108,30987.544,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-16",1,0.77,88.55,,0,0.001,48.818,0.058,0.004,0.009,837.298,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-17",10,9.92,2103.8,,0.004,0.001,863.728,0.058,0.087,0.0199,14805.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-18",24,24,5875,,0.012,0.001,2344.7,0.058,0.121,0.006,40184.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-19",24,24,5685,,0.012,0.001,2262.3,0.058,0.116,0.006,38774.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-20",20,18.88,4583.22,,0.009,0.001,1836.324,0.058,0.106,0.0087,31477.138,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-21",19,18,4253.8,,0.009,0.001,1721.68,0.058,0.103,0.0099,29510.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-22",20,19.35,4756.65,,0.01,0.001,1925.555,0.058,0.1,0.0064,33004.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-23",9,8.75,1945,,0.004,0.001,793.575,0.058,0.076,0.0212,13598.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-24",24,24,6037,,0.012,0.001,2419.9,0.058,0.124,0.006,41475.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-25",24,24,5602,,0.012,0.001,2270,0.058,0.117,0.006,38907,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-26",24,24,5579,,0.012,0.001,2242.1,0.058,0.114,0.0059,38431.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-27",24,24,5534,,0.011,0.001,2235.7,0.058,0.114,0.0059,38322.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-28",24,24,5693,,0.012,0.001,2294,0.058,0.117,0.006,39316.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-29",9,8.15,1931.6,,0.004,0.001,777.455,0.058,0.04,0.0064,13326.59,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"10",,"2020-12-31",9,8.63,1904.49,,0.004,0.001,778.949,0.058,0.093,0.0327,13350.757,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-02",6,5.02,451.86,,0.001,0.001,250.334,0.058,0.018,0.0087,4290.542,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-06",7,6.57,615.35,,0.002,0.001,330.179,0.058,0.024,0.0086,5661.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-10",7,5.91,538.71,,0.002,0.001,296.476,0.058,0.021,0.0099,5082.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-11",9,8.77,865.67,,0.002,0.001,450.275,0.058,0.033,0.009,7719.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-12",13,11.06,1051.24,,0.003,0.001,555.518,0.058,0.038,0.0082,9523.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-13",6,5.9,565.5,,0.002,0.001,294.73,0.058,0.021,0.0085,5051.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-14",9,8.2,785.32,,0.002,0.001,414.092,0.058,0.029,0.0107,7097.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-15",15,13.73,1342.36,,0.004,0.001,695.427,0.058,0.047,0.0081,11922.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-16",18,16.3,1583.37,,0.004,0.001,828.395,0.058,0.051,0.0083,14201.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-17",4,3.84,354.95,,0.001,0.001,190.147,0.058,0.014,0.009,3258.553,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-18",9,8.55,834.95,,0.002,0.001,439.03,0.058,0.03,0.0088,7526.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-19",10,8.72,832.88,,0.002,0.001,442.588,0.058,0.029,0.0082,7587.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-20",11,10.22,864.54,,0.002,0.001,459.75,0.058,0.028,0.0069,7877.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-21",8,5.47,467.2,,0.001,0.001,262.578,0.058,0.018,0.0131,4500.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-22",9,8.27,817.13,,0.002,0.001,424.711,0.058,0.028,0.0102,7279.634,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-23",17,15.68,1549.35,,0.004,0.001,803.111,0.0581,0.052,0.0075,13766.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-24",8,7.85,774.05,,0.002,0.001,400.265,0.058,0.027,0.008,6860.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-25",7,6.88,680.28,,0.002,0.001,354.368,0.058,0.025,0.0083,6072.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-26",7,5.03,431.59,,0.001,0.001,247.397,0.058,0.018,0.0097,4239.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-27",7,5.81,548.91,,0.001,0.001,290.275,0.058,0.021,0.008,4973.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-28",10,8.27,742.95,,0.002,0.001,412.219,0.058,0.037,0.0105,7064.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-29",10,9.37,887.53,,0.002,0.001,476.986,0.058,0.033,0.0088,8175.469,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-30",9,8.01,788.28,,0.002,0.001,406.156,0.058,0.029,0.0077,6962.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-01-31",11,10.3,1015.2,,0.003,0.001,532.98,0.058,0.036,0.01,9135.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-01",8,7.1,645.14,,0.002,0.001,350.968,0.058,0.026,0.0086,6016.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-15",4,3.2,279.92,,0.001,0.001,156.108,0.058,0.013,0.009,2676.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-16",4,3.22,269.73,,0.001,0.001,157.993,0.058,0.014,0.0108,2708.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-17",6,4.79,448.51,,0.001,0.001,238.322,0.058,0.019,0.0075,4085.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-18",11,9.8,923.52,,0.003,0.001,497.348,0.058,0.037,0.0089,8522.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-19",6,4.38,352.6,,0.001,0.001,214.611,0.058,0.016,0.0098,3678.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-21",5,4.35,381.3,,0.001,0.001,215.502,0.058,0.019,0.012,3693.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-22",4,3.35,280.9,,0.001,0.001,164.07,0.058,0.013,0.0103,2813.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-24",8,6.4,612.84,,0.002,0.001,323.536,0.0581,0.022,0.0088,5545.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-26",5,4.33,390.5,,0.001,0.001,216.116,0.058,0.017,0.0092,3702.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-28",6,4.7,422.3,,0.001,0.001,234.29,0.058,0.018,0.011,4015.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-01",6,5.1,476,,0.001,0.001,257.775,0.058,0.019,0.0083,4417.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-03",5,4.92,484.12,,0.001,0.001,254.148,0.058,0.019,0.0088,4355.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-04",9,7.64,723.31,,0.002,0.001,387.697,0.058,0.027,0.0084,6642.562,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-05",5,2.85,238.08,,0.001,0.001,135.759,0.058,0.011,0.0068,2328.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-09",5,4.63,421.13,,0.001,0.001,234.039,0.058,0.02,0.0104,4011.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-15",3,2.46,204.96,,0.001,0.001,119.026,0.058,0.011,0.014,2040.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-16",10,8.7,837.63,,0.002,0.001,445.163,0.058,0.03,0.008,7630.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-20",2,1.35,97.39,,0,0.001,60.847,0.058,0.006,0.01,1042.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-21",3,2.11,154.99,,0.001,0.001,101.317,0.058,0.009,0.0127,1737.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-22",5,4.47,402.78,,0.001,0.001,221.639,0.058,0.018,0.0096,3797.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-25",11,9.28,853.17,,0.002,0.001,467.639,0.058,0.035,0.0106,8014.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-26",4,2.36,203.16,,0.001,0.001,115.276,0.058,0.01,0.0125,1976.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-03-31",7,6.53,628.85,,0.002,0.001,330.685,0.058,0.024,0.0096,5667.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-01",5,3.92,338.83,,0.001,0.001,195.731,0.058,0.015,0.0102,3353.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-02",15,12.42,1205.67,,0.003,0.001,633.35,0.058,0.044,0.0089,10856.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-04",8,7.47,729.27,,0.002,0.001,384.72,0.058,0.03,0.0104,6594.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-05",1,0.25,2.75,,0,0.001,6.875,0.058,0,0.006,117.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-07",7,6.44,610.32,,0.002,0.001,324.576,0.058,0.025,0.0091,5563.132,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-09",4,3.33,294.64,,0.001,0.001,164.33,0.058,0.014,0.01,2816.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-10",3,2.9,277.6,,0.001,0.001,145.22,0.058,0.013,0.011,2489.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-11",1,0.62,29.76,,0,0.001,25.42,0.058,0.002,0.008,435.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-13",5,3.63,322.55,,0.001,0.001,179.229,0.058,0.015,0.011,3072.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-04-30",2,2,0,,0,0.001,4.6,0.058,0,0.006,78.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-01",3,1.95,141.72,,0,0.001,91.983,0.058,0.008,0.0097,1576.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-02",7,6.9,682.5,,0.002,0.001,355,0.058,0.027,0.009,6084.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-03",8,7.24,655.67,,0.002,0.001,362.71,0.058,0.029,0.0094,6214.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-05",9,8.07,777.21,,0.002,0.001,410.457,0.058,0.031,0.0083,7034.669,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-07",3,1.7,132.15,,0,0.001,79.08,0.058,0.008,0.0087,1355.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-08",7,6.03,578.7,,0.002,0.001,303.311,0.058,0.021,0.0071,5198.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-10",3,1.52,112.6,,0,0.001,70.464,0.058,0.007,0.012,1207.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-16",10,9.15,874.67,,0.002,0.001,468.266,0.058,0.033,0.0103,8024.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-19",5,4.63,436.76,,0.001,0.001,235.257,0.058,0.019,0.0104,4033.423,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-20",2,1.55,124.1,,0,0.001,74.56,0.058,0.005,0.008,1277.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-22",3,1.3,99.8,,0,0.001,59.51,0.0583,0.005,0.013,1020.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-24",4,2.9,237.1,,0.001,0.001,142.761,0.058,0.012,0.0108,2447.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-25",5,4.2,364.92,,0.001,0.001,211.544,0.058,0.017,0.0106,3627.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-26",9,7.82,730.42,,0.002,0.001,399.112,0.058,0.028,0.0096,6839.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-27",6,5.17,468.11,,0.001,0.001,257.476,0.058,0.021,0.0095,4413.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-28",4,3.93,369.84,,0.001,0.001,196.514,0.058,0.015,0.0088,3368.397,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-29",8,5.07,433.2,,0.001,0.001,247.654,0.058,0.022,0.0089,4243.407,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-05-31",7,6.8,650.08,,0.002,0.001,348.032,0.058,0.027,0.0091,5964.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-01",12,11.4,1090.2,,0.003,0.001,587.644,0.058,0.044,0.0092,10074.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-02",17,16.15,1601.17,,0.004,0.001,836.482,0.058,0.057,0.0077,14338.629,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-03",17,16.48,1612.46,,0.004,0.001,850.031,0.058,0.053,0.0073,14568.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-04",9,7.57,719.8,,0.002,0.001,384.902,0.0581,0.026,0.008,6594.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-06",4,3.8,349.22,,0.001,0.001,190.6,0.058,0.013,0.0083,3267.229,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-07",4,3.48,267.2,,0.001,0.001,158.38,0.058,0.011,0.009,2714.887,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-08",9,8.43,819.91,,0.002,0.001,442.066,0.058,0.03,0.0092,7578.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-09",1,0.67,36.18,,0,0.001,29.279,0.058,0.002,0.007,501.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-10",11,9.32,908.8,,0.002,0.001,479.552,0.058,0.029,0.0082,8219.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-11",7,5.56,519.91,,0.001,0.001,281.703,0.058,0.02,0.0084,4828.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-13",5,3.55,312.12,,0.001,0.001,177.169,0.058,0.012,0.0106,3037.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-14",2,1.08,61.74,,0,0.001,48.114,0.058,0.007,0.012,824.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-15",8,6.35,605.5,,0.002,0.001,323.545,0.058,0.021,0.009,5545.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-18",3,1.21,95.65,,0,0.001,53.988,0.058,0.004,0.011,925.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-22",9,8.18,786.91,,0.002,0.001,420.374,0.058,0.027,0.0072,7203.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-24",6,5.17,497.51,,0.001,0.001,261.837,0.058,0.019,0.0075,4487.554,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-26",9,6.95,604.28,,0.002,0.001,345.678,0.058,0.025,0.0084,5925.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-27",9,8.14,785.96,,0.002,0.001,416.068,0.058,0.027,0.0072,7132.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-28",11,9.65,922.55,,0.003,0.001,495.925,0.058,0.031,0.0087,8501.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-06-30",4,3.47,303.3,,0.001,0.001,173.318,0.058,0.013,0.0098,2972.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-02",4,2.74,223.84,,0.001,0.001,134.677,0.058,0.01,0.0098,2308.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-03",3,2.85,253.85,,0.001,0.001,141.125,0.058,0.011,0.0087,2418.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-06",12,10.52,1009.5,,0.003,0.001,540.556,0.058,0.034,0.0073,9264.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-07",9,8.1,762.74,,0.002,0.001,416.102,0.058,0.027,0.0093,7132.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-09",6,5.41,493.43,,0.001,0.001,275.231,0.058,0.02,0.0087,4717.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-12",11,9.99,966.73,,0.003,0.001,512.906,0.058,0.033,0.0071,8793.883,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-16",3,2.58,217.58,,0.001,0.001,126.934,0.058,0.01,0.01,2176.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-19",3,1.9,142.35,,0,0.001,90.4,0.058,0.008,0.0093,1549.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-25",5,3.4,302.45,,0.001,0.001,166.145,0.0582,0.012,0.0096,2848.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-27",5,3.85,331.52,,0.001,0.001,191.211,0.058,0.013,0.0086,3276.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-01",6,5.47,501.71,,0.001,0.001,275.821,0.058,0.019,0.0088,4727.223,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-03",2,1.1,68.45,,0,0.001,47.73,0.058,0.005,0.0095,818.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-07",4,2.86,240.38,,0.001,0.001,139.962,0.058,0.009,0.0113,2399.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-09",5,3.48,308.32,,0.001,0.001,170.229,0.058,0.011,0.0102,2918.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-11",4,3.68,324.52,,0.001,0.001,181.056,0.058,0.014,0.0093,3103.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-13",9,7.28,700.9,,0.002,0.001,367.205,0.0581,0.021,0.0081,6293.678,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-15",6,4.77,430.9,,0.001,0.001,237.808,0.058,0.017,0.008,4075.967,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-16",7,6.6,613.92,,0.002,0.001,331.664,0.058,0.022,0.0081,5686.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-17",8,7.05,683.18,,0.002,0.001,356.262,0.058,0.023,0.0069,6103.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-19",8,6.94,663.6,,0.002,0.001,350.562,0.058,0.023,0.0069,6008.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-23",9,7.64,720.1,,0.002,0.001,384.808,0.0581,0.026,0.0074,6594.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-28",9,8.33,785.62,,0.002,0.001,423.527,0.058,0.027,0.0074,7259.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-01",7,6.4,589.5,,0.002,0.001,321.466,0.058,0.021,0.008,5508.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-04",9,7.32,700.4,,0.002,0.001,366.564,0.0581,0.023,0.0083,6283.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-05",7,5.8,539.53,,0.001,0.001,288.231,0.0581,0.02,0.0074,4941.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-06",4,3.08,267.72,,0.001,0.001,147.412,0.058,0.01,0.0118,2526.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-07",6,4.43,405.9,,0.001,0.001,218.155,0.058,0.014,0.0095,3738.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-11",2,0.9,44.32,,0,0.001,43.112,0.058,0.005,0.019,739.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-16",3,1.4,55.85,,0,0.001,40.39,0.0583,0.004,0.0077,691.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-20",10,9,862.92,,0.002,0.001,451.554,0.058,0.031,0.0079,7740.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-23",8,7.87,762.11,,0.002,0.001,396.686,0.058,0.026,0.0076,6799.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-09-30",7,5.82,528.78,,0.001,0.001,288.83,0.058,0.02,0.0093,4949.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-03",11,9.22,901.2,,0.002,0.001,462.912,0.058,0.031,0.0066,7933.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-04",9,7.67,727.4,,0.002,0.001,384.032,0.0581,0.025,0.0076,6581.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-06",9,7.62,718.36,,0.002,0.001,383.638,0.058,0.025,0.0082,6573.162,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-08",8,6.4,610.1,,0.002,0.001,319.77,0.058,0.02,0.0083,5479.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-09",9,8.15,806.05,,0.002,0.001,417.325,0.058,0.026,0.0088,7155.745,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-10",7,4.87,419.6,,0.001,0.001,235.523,0.058,0.016,0.0089,4036.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-11",10,8.64,818.91,,0.002,0.001,435.263,0.058,0.028,0.0088,7459.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-12",4,3.08,249.23,,0.001,0.001,148.75,0.058,0.011,0.009,2550.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-14",6,4.42,405.47,,0.001,0.001,220.587,0.058,0.015,0.0087,3781.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-15",10,8.75,779.75,,0.002,0.001,426.275,0.058,0.027,0.0094,7306.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-16",9,6.57,585.29,,0.002,0.001,322.226,0.0581,0.022,0.01,5521.931,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-19",4,2.99,244.89,,0.001,0.001,145.738,0.058,0.01,0.012,2497.843,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-25",7,6.64,623.28,,0.002,0.001,333.737,0.058,0.024,0.0089,5718.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-30",5,3.11,292,,0.001,0.001,151.539,0.058,0.012,0.0064,2596.289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-01",6,5.2,478.85,,0.001,0.001,258.785,0.058,0.019,0.0083,4435.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-02",7,5.31,506.63,,0.001,0.001,266.906,0.058,0.016,0.0086,4573.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-03",7,5.56,514.36,,0.001,0.001,280.904,0.058,0.019,0.0096,4815.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-04",5,3.72,329.65,,0.001,0.001,183.552,0.0582,0.013,0.0078,3146.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-05",8,6.82,641.21,,0.002,0.001,341.792,0.058,0.021,0.007,5858.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-08",5,4.14,391.78,,0.001,0.001,205.14,0.058,0.014,0.007,3514.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-10",8,6.82,637.2,,0.002,0.001,343.014,0.058,0.02,0.0075,5880.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-12",4,2.7,221.89,,0.001,0.001,131.136,0.058,0.012,0.0163,2248.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-18",4,3.1,145.6,,0.001,0.001,101.57,0.058,0.007,0.008,1741.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-22",3,1.29,100.78,,0,0.001,57.756,0.0583,0.007,0.0063,990.421,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"11",,"2020-12-31",4,3.75,339.41,,0.001,0.001,180.802,0.058,0.015,0.01,3098.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-12",2,1.39,94.18,,0,0.001,62.073,0.058,0.008,0.013,1064.869,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-20",11,8.4,768.26,,0.002,0.001,414.078,0.058,0.03,0.0105,7096.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-21",8,6.31,609.54,,0.002,0.001,315.152,0.058,0.023,0.0091,5402.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-22",9,8.62,847.34,,0.002,0.001,443.584,0.058,0.032,0.0093,7603.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-23",9,8.18,815.9,,0.002,0.001,417.61,0.058,0.025,0.0068,7159.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-27",3,2.35,184.54,,0.001,0.001,113.53,0.058,0.011,0.0143,1945.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-29",8,6.42,610.97,,0.002,0.001,324.805,0.058,0.022,0.0113,5565.552,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-01",7,5.68,524.34,,0.001,0.001,284.484,0.058,0.021,0.0099,4876.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-04",13,10.45,1016.95,,0.003,0.001,527.18,0.058,0.032,0.0123,9033.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-05",17,16.57,1639.03,,0.004,0.001,842.794,0.058,0.053,0.0074,14448.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-06",10,8.45,814.39,,0.002,0.001,427.29,0.058,0.029,0.0095,7323.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-07",7,5.45,479.69,,0.001,0.001,267.551,0.058,0.021,0.0101,4586.327,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-08",3,2.01,136.33,,0,0.001,90.564,0.058,0.009,0.0143,1552.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-10",8,7.75,761.25,,0.002,0.001,395.8,0.058,0.032,0.0101,6784.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-11",1,0.62,29.76,,0,0.001,26.04,0.058,0.001,0.006,446.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-13",6,5.93,592.7,,0.002,0.001,304.193,0.058,0.022,0.0087,5213.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-14",8,6.47,614.11,,0.002,0.001,326.58,0.058,0.021,0.0113,5595.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-15",8,7.58,738.68,,0.002,0.001,387.06,0.058,0.023,0.0069,6631.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-20",8,7.37,719.1,,0.002,0.001,378.317,0.058,0.026,0.0099,6484.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-21",8,7.45,727.4,,0.002,0.001,382.69,0.058,0.023,0.0069,6557.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-25",1,0.17,0,,0,0.001,1.428,0.058,0.001,0.046,24.531,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-26",2,0.34,0,,0,0.001,2.754,0.058,0,0.019,47.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-28",8,7.5,709.08,,0.002,0.001,377.895,0.058,0.027,0.009,6479.127,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-03-31",4,3.41,150.2,,0.001,0.001,105.178,0.058,0.011,0.0128,1801.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-05",2,1.23,84.06,,0,0.001,54.303,0.058,0.006,0.023,930.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-12",7,6.28,582.48,,0.002,0.001,314.086,0.058,0.024,0.0109,5381.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-21",2,1.16,31.96,,0,0.001,32.88,0.058,0.004,0.0185,563.707,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-25",2,1.11,51.03,,0,0.001,48.036,0.058,0.007,0.017,823.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-27",2,1.38,99.54,,0,0.001,62.7,0.058,0.008,0.021,1074.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-01",3,1.87,148.1,,0,0.001,88.096,0.058,0.006,0.015,1510.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-05",9,7.9,733.95,,0.002,0.001,400.86,0.058,0.031,0.0101,6870.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-06",11,10.73,1040.39,,0.003,0.001,548.075,0.058,0.038,0.0082,9395.189,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-07",12,11.32,1092,,0.003,0.001,577.388,0.058,0.04,0.0099,9898.742,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-09",8,6.9,660.94,,0.002,0.001,343.9,0.0581,0.028,0.0091,5892.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-15",2,1.22,81.36,,0,0.001,54.346,0.058,0.008,0.0125,932.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-19",3,2.23,182.87,,0.001,0.001,106.246,0.058,0.012,0.0117,1820.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-22",2,1.43,87.98,,0,0.001,65.096,0.058,0.008,0.014,1115.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-27",5,4.05,358.4,,0.001,0.001,201.46,0.058,0.018,0.0106,3453.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-29",3,2.44,195.98,,0.001,0.001,117.927,0.058,0.012,0.0113,2020.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-03",5,4.13,371.71,,0.001,0.001,205.255,0.058,0.016,0.009,3519.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-09",8,6.8,633.2,,0.002,0.001,345.728,0.058,0.025,0.0121,5923.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-14",2,1.48,96.84,,0,0.001,69.044,0.058,0.011,0.017,1183.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-22",9,8.15,789.75,,0.002,0.001,417.02,0.058,0.031,0.008,7148.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-28",9,8.25,809.5,,0.002,0.001,425.675,0.058,0.029,0.0117,7298.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-29",1,0.28,4.2,,0,0.001,8.68,0.058,0,0.005,148.652,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-06-30",8,7.46,721.72,,0.002,0.001,387.546,0.058,0.028,0.0101,6640.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-07",3,1.85,128.67,,0,0.001,87.425,0.058,0.008,0.0157,1498.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-10",12,10.36,1007.16,,0.003,0.001,534.244,0.0581,0.036,0.0098,9155.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-11",12,10.25,1005.5,,0.003,0.001,530.2,0.058,0.033,0.0083,9089.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-15",7,6.04,575.98,,0.002,0.001,306.305,0.0581,0.022,0.0074,5248.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-17",2,0.19,0,,0,0.001,1.513,0.058,0.001,0.0295,25.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-21",3,2.11,174.23,,0.001,0.001,99.052,0.058,0.008,0.0083,1698.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-26",9,8.15,760.67,,0.002,0.001,409.762,0.058,0.027,0.0081,7023.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-27",6,5.24,467.68,,0.001,0.001,262,0.058,0.02,0.0102,4488.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-28",8,6.55,616.92,,0.002,0.001,329.384,0.058,0.022,0.0076,5644.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-29",10,8.9,854.42,,0.002,0.001,451.06,0.058,0.031,0.0078,7730.647,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-30",10,9.05,856.99,,0.002,0.001,458.188,0.058,0.031,0.0081,7854.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-07-31",11,9.79,935.03,,0.003,0.001,496.866,0.058,0.033,0.0103,8517.698,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-02",5,3.15,291.72,,0.001,0.001,154.427,0.0582,0.01,0.0094,2647.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-03",2,1.08,67.74,,0,0.001,47.604,0.058,0.007,0.012,816.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-04",7,5.85,553.94,,0.002,0.001,293.072,0.058,0.02,0.0073,5021.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-05",3,2.22,170.18,,0.001,0.001,106.612,0.058,0.01,0.016,1828.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-06",2,1.05,66.5,,0,0.001,45.608,0.058,0.007,0.012,782.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-10",5,4.32,375.22,,0.001,0.001,213.85,0.058,0.018,0.011,3665.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-11",4,3.32,290.52,,0.001,0.001,162.256,0.058,0.013,0.0085,2782.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-12",11,9.17,899.07,,0.002,0.001,463.1,0.058,0.032,0.0079,7934.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-13",10,9,878.77,,0.002,0.001,457.011,0.058,0.031,0.0073,7834.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-14",12,10.21,997.16,,0.003,0.001,520.794,0.058,0.033,0.0096,8924.989,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-15",11,10.46,992.31,,0.003,0.001,527.163,0.058,0.035,0.0086,9034.663,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-16",9,7.77,727.4,,0.002,0.001,391.366,0.058,0.028,0.012,6707.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-17",9,8.65,824.9,,0.002,0.001,437.636,0.058,0.03,0.008,7502.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-18",10,8.43,785.5,,0.002,0.001,415.923,0.058,0.03,0.0079,7128.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-19",8,6.42,606.15,,0.002,0.001,324.151,0.0581,0.023,0.0096,5556.891,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-21",10,8.6,824.74,,0.002,0.001,433.098,0.058,0.031,0.0086,7421.597,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-22",10,9.84,958.72,,0.003,0.001,502.348,0.058,0.034,0.0079,8610.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-23",10,9.78,949.64,,0.003,0.001,498.056,0.058,0.034,0.0082,8534.047,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-24",9,8.78,831.66,,0.002,0.001,439.096,0.058,0.03,0.0081,7526.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-25",8,7.16,679.36,,0.002,0.001,361,0.058,0.027,0.0085,6187.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-26",8,7.45,701.05,,0.002,0.001,373.67,0.058,0.026,0.008,6404.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-27",9,7.33,703.14,,0.002,0.001,368.408,0.058,0.025,0.0104,6315.929,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-02",10,9.25,892.67,,0.002,0.001,469.942,0.058,0.032,0.0106,8058.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-03",5,4.09,350.4,,0.001,0.001,199.742,0.058,0.017,0.0112,3423.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-04",6,5.35,478.59,,0.001,0.001,266.191,0.058,0.019,0.0088,4563.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-05",9,8.17,766.27,,0.002,0.001,410.081,0.058,0.029,0.01,7029.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-06",10,8.13,795.5,,0.002,0.001,407.841,0.058,0.026,0.0087,6989.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-07",8,6.8,637.2,,0.002,0.001,338.744,0.058,0.021,0.0098,5806.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-14",2,1.44,49.65,,0,0.001,41.496,0.058,0.005,0.0125,711.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-15",5,3.93,348.13,,0.001,0.001,197.225,0.058,0.015,0.015,3381.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-26",9,7.72,733.23,,0.002,0.001,389.308,0.058,0.028,0.0089,6671.479,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-29",11,10.13,970.64,,0.003,0.001,516.914,0.058,0.041,0.0096,8859.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-03",3,1.52,78.05,,0,0.001,60.712,0.058,0.01,0.027,1040.019,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-04",2,1.67,66.48,,0,0.001,49.119,0.058,0.006,0.016,841.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-05",5,4.34,378.01,,0.001,0.001,212.935,0.058,0.015,0.01,3648.162,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-10",3,2.69,229.4,,0.001,0.001,129.077,0.058,0.012,0.011,2211.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-16",4,2.93,249.66,,0.001,0.001,139.269,0.058,0.01,0.017,2387.569,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-24",3,2,143.54,,0,0.001,92.318,0.058,0.009,0.017,1583.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-02",7,4.73,322.19,,0.001,0.0009,194.527,0.058,0.023,0.013,3336.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-16",2,1.18,65.76,,0,0.001,49.544,0.058,0.008,0.0145,849.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-26",3,1.84,137.26,,0,0.001,84.058,0.058,0.009,0.0113,1440.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"12",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-06",16,14.38,1294.6,,0.003,0.001,677.558,0.0581,0.042,0.0085,11612.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-07",14,13.37,1310.1,,0.004,0.001,682.458,0.058,0.044,0.0088,11696.917,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-11",10,9.85,978.15,,0.003,0.001,501.605,0.058,0.035,0.0084,8596.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-12",10,7.73,719.98,,0.002,0.001,379.932,0.058,0.026,0.0095,6509.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-13",17,15.58,1527.77,,0.004,0.001,785.933,0.058,0.052,0.0093,13468.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-14",7,5.53,513.42,,0.001,0.001,271.779,0.058,0.018,0.0107,4656.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-15",11,9.63,911.28,,0.002,0.001,473.94,0.0581,0.035,0.0103,8122.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-16",9,8.02,754.27,,0.002,0.001,402.345,0.058,0.028,0.0104,6894.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-17",14,12.6,1198.74,,0.003,0.001,634.926,0.058,0.039,0.0095,10880.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-18",17,16.17,1608.87,,0.004,0.001,820.601,0.058,0.045,0.0076,14065.301,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-19",16,14.95,1490.88,,0.004,0.0009,758.749,0.0581,0.042,0.0061,13004.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-20",11,9.58,921.98,,0.002,0.001,480.338,0.058,0.031,0.0085,8233.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-21",16,14.35,1303.43,,0.004,0.001,695.733,0.058,0.047,0.0093,11922.007,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-22",4,3.31,295.27,,0.001,0.001,162.45,0.058,0.012,0.008,2785.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-23",9,8.17,810.53,,0.002,0.001,416.323,0.058,0.027,0.0102,7135.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-24",12,10.72,1048.8,,0.003,0.001,542.765,0.058,0.035,0.0076,9302.222,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-25",2,1.78,151.7,,0,0.001,86.242,0.058,0.005,0.0065,1477.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-27",10,7.68,673.28,,0.002,0.001,375.715,0.0581,0.03,0.01,6438.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-29",3,1.75,140.6,,0,0.001,80.905,0.058,0.009,0.009,1387.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-30",7,6.79,645.71,,0.002,0.001,339.775,0.058,0.022,0.0076,5825.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-01-31",11,9.68,910.41,,0.003,0.001,486.471,0.058,0.034,0.0108,8337.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-01",4,2.8,200.04,,0.001,0.001,130.136,0.058,0.011,0.0093,2230.421,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-03",8,7.52,731.92,,0.002,0.001,385.124,0.058,0.027,0.0095,6599.144,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-04",15,13.97,1320.28,,0.004,0.001,698.648,0.058,0.051,0.0085,11975.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-05",20,18.63,1850.5,,0.005,0.001,944.759,0.058,0.06,0.0076,16193.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-06",5,3.78,314.76,,0.001,0.001,180.491,0.058,0.012,0.0122,3093.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-11",8,7.98,787.14,,0.002,0.001,400.126,0.058,0.027,0.0079,6856.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-12",11,8.31,757.34,,0.002,0.001,414.127,0.0581,0.038,0.0117,7098.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-13",8,7.72,754.52,,0.002,0.001,394.2,0.058,0.025,0.0078,6753.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-14",10,9.01,858.41,,0.002,0.001,454.742,0.058,0.026,0.0089,7793.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-15",8,7.95,787.9,,0.002,0.001,403.035,0.058,0.021,0.006,6906.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-17",10,7.17,631.65,,0.002,0.001,347.879,0.058,0.032,0.0105,5958.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-18",17,15.33,1365.5,,0.004,0.001,720.783,0.058,0.042,0.0079,12355.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-19",8,5.38,423.5,,0.001,0.001,256.072,0.058,0.02,0.0105,4387.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-24",7,6.16,563.56,,0.002,0.001,308.14,0.058,0.022,0.0101,5281.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-26",5,3.92,348.56,,0.001,0.001,192.08,0.058,0.015,0.0088,3294.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-02-29",5,3.97,371.3,,0.001,0.001,196.739,0.058,0.016,0.0092,3371.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-01",6,4.65,420.35,,0.001,0.001,231.18,0.058,0.017,0.0103,3963.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-03",5,4.08,404.08,,0.001,0.001,207.3,0.058,0.012,0.008,3552.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-04",9,7.63,721.93,,0.002,0.001,383.668,0.058,0.024,0.0098,6577.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-05",13,11.97,1106.12,,0.003,0.001,601.264,0.058,0.042,0.0085,10307.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-06",4,2.54,177.68,,0.001,0.001,117.094,0.058,0.011,0.0095,2006.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-12",14,12.57,1188.14,,0.003,0.001,620.785,0.058,0.039,0.0087,10640.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-16",3,2.08,174.56,,0.001,0.001,99.092,0.058,0.01,0.0093,1697.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-18",4,2.35,206.9,,0.001,0.001,112.523,0.058,0.008,0.0118,1928.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-21",1,0.35,3.15,,0,0.001,6.895,0.058,0.002,0.041,118.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-22",2,0.45,4.9,,0,0.001,9.755,0.058,0.001,0.011,167.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-23",1,0.48,7.68,,0,0.001,11.088,0.058,0.001,0.011,189.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-25",3,2.46,146.53,,0,0.001,94.337,0.058,0.008,0.0107,1617.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-04-30",2,2,0,,0,0.001,4.2,0.059,0,0.011,71.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-04",8,6.5,614.12,,0.002,0.001,328.56,0.058,0.022,0.0078,5629.402,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-07",3,2.48,194.8,,0.001,0.001,117.863,0.058,0.012,0.0123,2018.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-10",3,1.52,112.2,,0,0.001,69.696,0.058,0.009,0.0163,1194.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-14",15,14.22,1414.08,,0.004,0.001,730.784,0.058,0.047,0.0105,12526.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-15",7,6.28,610.2,,0.002,0.001,317.82,0.058,0.019,0.0067,5446.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-17",6,5.9,580.6,,0.002,0.001,303.14,0.058,0.024,0.0095,5196.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-18",7,6.03,595,,0.002,0.001,308.428,0.058,0.018,0.006,5287.027,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-22",2,1.2,63.12,,0,0.001,53.232,0.058,0.007,0.0125,911.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-27",3,1.95,161.5,,0,0.001,91.557,0.058,0.011,0.0103,1569.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-28",10,9.55,925.93,,0.003,0.001,497.583,0.058,0.041,0.0102,8528.821,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-29",5,3.62,321.4,,0.001,0.001,178.052,0.058,0.017,0.0104,3050.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-05-31",7,5.97,556.76,,0.002,0.001,300.745,0.058,0.028,0.011,5153.879,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-02",10,8.73,829.85,,0.002,0.001,444.515,0.058,0.031,0.0086,7618.723,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-03",13,11.85,1134.45,,0.003,0.001,602.945,0.058,0.041,0.0105,10332.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-04",8,6.73,631.12,,0.002,0.001,338.77,0.058,0.025,0.0091,5807.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-05",11,9.73,941.16,,0.003,0.001,497.189,0.0581,0.035,0.008,8522.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-06",4,3.37,285.71,,0.001,0.001,166.124,0.058,0.018,0.013,2846.477,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-10",11,10,969.6,,0.003,0.001,511.792,0.058,0.034,0.0097,8770.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-11",7,5.99,572.2,,0.002,0.001,301.435,0.0581,0.023,0.008,5165.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-13",5,4.57,430.5,,0.001,0.001,235.733,0.058,0.019,0.0114,4039.823,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-14",8,6.43,574.23,,0.002,0.001,321.027,0.058,0.021,0.01,5502.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-15",8,6.59,616.89,,0.002,0.001,333.893,0.058,0.024,0.0126,5721.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-16",6,5.49,510.03,,0.001,0.001,276.776,0.058,0.021,0.0088,4744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-17",5,4.43,391.08,,0.001,0.001,222.309,0.058,0.021,0.0118,3809.979,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-22",10,8.68,825.36,,0.002,0.001,443.244,0.058,0.032,0.0093,7598.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-25",4,3.4,305.4,,0.001,0.001,167.66,0.058,0.018,0.0113,2873.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-26",7,5.34,505.31,,0.001,0.001,268.669,0.058,0.022,0.009,4604.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-27",5,3.69,317.89,,0.001,0.001,181.757,0.058,0.016,0.0172,3114.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-28",6,5.1,455.5,,0.001,0.001,255.228,0.058,0.021,0.0102,4373.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-29",13,11.97,1177.9,,0.003,0.0009,613.336,0.058,0.043,0.0076,10511.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-06-30",4,3.47,302.78,,0.001,0.001,171.969,0.058,0.015,0.0138,2947.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-03",4,3.27,280.03,,0.001,0.001,161.619,0.058,0.015,0.0163,2768.681,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-05",4,2.95,261.45,,0.001,0.001,143.945,0.058,0.014,0.0093,2467.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-06",12,10.61,1018.16,,0.003,0.001,541.951,0.058,0.037,0.0087,9289.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-07",10,8.32,797.5,,0.002,0.001,424.364,0.0581,0.029,0.0106,7272.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-09",8,6.12,593,,0.002,0.001,310.897,0.058,0.024,0.008,5329.446,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-10",11,9.78,942.8,,0.003,0.001,502.626,0.058,0.035,0.0079,8612.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-12",13,12.43,1189.93,,0.003,0.001,637.379,0.058,0.043,0.0085,10923.469,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-13",8,6.48,610.91,,0.002,0.001,330.722,0.058,0.024,0.0093,5667.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-14",15,14.78,1449.86,,0.004,0.001,761.956,0.058,0.05,0.0078,13061.007,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-15",16,14.97,1470.08,,0.004,0.001,773.035,0.058,0.056,0.0084,13249.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-17",3,1.8,130.2,,0,0.001,84.28,0.058,0.009,0.025,1445.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-18",4,2.79,230.26,,0.001,0.001,134.624,0.058,0.012,0.0108,2308.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-20",12,10.24,1003.51,,0.003,0.001,516.963,0.058,0.038,0.0083,8863.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-26",7,5.61,517.81,,0.001,0.001,278.418,0.058,0.022,0.011,4771.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-29",8,6.84,635.06,,0.002,0.001,343.442,0.058,0.025,0.0141,5887.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-30",10,8.45,806.78,,0.002,0.001,425.396,0.058,0.032,0.0107,7294.123,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-02",5,3.69,321.56,,0.001,0.001,181.562,0.058,0.016,0.0122,3113.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-04",5,3.45,307.45,,0.001,0.001,169.2,0.058,0.013,0.0152,2900.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-06",7,6.11,563.76,,0.002,0.001,308.666,0.058,0.024,0.0097,5291.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-09",5,4.04,344.78,,0.001,0.001,198.672,0.058,0.018,0.0134,3404.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-12",8,6.63,617.88,,0.002,0.001,331.168,0.058,0.025,0.0101,5677.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-14",8,6.79,637.78,,0.002,0.001,342.852,0.058,0.026,0.0091,5877.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-18",8,7.09,647.23,,0.002,0.001,353.695,0.058,0.025,0.0089,6061.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-22",8,7.75,739.75,,0.002,0.001,391.325,0.058,0.032,0.0103,6705.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-26",10,8.71,832.16,,0.002,0.001,437.625,0.058,0.03,0.0078,7500.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-27",8,7.21,672.26,,0.002,0.001,361.085,0.058,0.026,0.011,6187.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-01",7,6.15,568.34,,0.002,0.001,306.431,0.058,0.023,0.013,5250.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-05",9,7.98,739.75,,0.002,0.001,399.805,0.058,0.028,0.0093,6851.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-06",4,3.18,272.02,,0.001,0.001,151.804,0.058,0.013,0.017,2602.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-11",3,2.15,163.82,,0.001,0.001,106.049,0.058,0.01,0.0137,1817.979,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-15",11,10.11,993.29,,0.003,0.001,507.997,0.058,0.035,0.0075,8703.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-17",9,7.37,705.23,,0.002,0.001,369.443,0.0581,0.025,0.011,6332.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-18",11,10.05,855.18,,0.002,0.001,452.167,0.058,0.031,0.0072,7751.577,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-21",5,4.38,394.43,,0.001,0.001,215.027,0.058,0.018,0.0128,3686.132,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-24",9,7.72,731.65,,0.002,0.001,387.333,0.0581,0.029,0.0089,6638.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-25",7,5.83,529.22,,0.001,0.001,288.317,0.058,0.022,0.0113,4942.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-28",5,4.25,375.29,,0.001,0.001,207.127,0.058,0.017,0.0134,3549.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-09-30",8,6.83,640.11,,0.002,0.001,336.235,0.058,0.026,0.009,5764.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-02",10,8.47,808.33,,0.002,0.001,422.657,0.058,0.03,0.0108,7244.133,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-06",9,7.94,749.56,,0.002,0.001,397.434,0.058,0.03,0.0088,6809.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-07",8,6.62,617.9,,0.002,0.001,333.85,0.058,0.025,0.0106,5720.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-08",7,6.31,576.34,,0.002,0.001,313.593,0.058,0.024,0.0099,5376.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-09",9,8.3,808.2,,0.002,0.001,423.06,0.058,0.03,0.0117,7252.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-10",11,8.92,833.6,,0.002,0.001,440.263,0.0581,0.033,0.0077,7544.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-11",8,7.54,704.41,,0.002,0.001,375.4,0.058,0.03,0.01,6436.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-12",3,1.95,141.1,,0,0.001,92.57,0.058,0.01,0.013,1586.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-13",7,5.75,532.5,,0.001,0.001,288.531,0.058,0.021,0.0089,4943.421,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-14",4,2.57,214.5,,0.001,0.001,122.882,0.058,0.012,0.0115,2107.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-15",2,1.23,38.8,,0,0.001,34.34,0.058,0.005,0.0145,588.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-16",7,5.81,544.64,,0.001,0.001,289.775,0.058,0.025,0.0099,4966.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-19",4,2.77,237.76,,0.001,0.001,133.803,0.058,0.014,0.0103,2294.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-23",12,11.08,1054.49,,0.003,0.001,566.158,0.058,0.038,0.0084,9704.661,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-25",7,6.53,602.98,,0.002,0.001,323.655,0.058,0.026,0.01,5548.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-10-31",4,3.08,270.37,,0.001,0.001,150.75,0.058,0.015,0.0103,2583.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-01",6,5.75,539.67,,0.001,0.001,285.018,0.058,0.025,0.0112,4886.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-02",7,5.99,567.99,,0.002,0.001,299.432,0.058,0.022,0.0111,5133.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-03",7,5.72,528.28,,0.001,0.001,287.305,0.058,0.02,0.0126,4924.597,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-05",7,5.48,510.9,,0.001,0.001,271.713,0.058,0.022,0.0086,4658.423,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-08",6,5.08,455.28,,0.001,0.001,252.356,0.058,0.021,0.0137,4326.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-13",1,1,0,,0,0.001,2.4,0.059,0,0.011,40.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-26",3,1.86,151.64,,0,0.001,87.935,0.058,0.008,0.008,1506.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-02",8,6.24,574.48,,0.002,0.001,292.884,0.058,0.02,0.0088,5018.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"13",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-08",1,0.98,91.14,,0,0.001,47.824,0.058,0.008,0.02,819.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-24",3,1.43,105.97,,0,0.001,64.532,0.058,0.007,0.017,1106.483,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-27",6,5.32,482.36,,0.001,0.001,262.944,0.058,0.025,0.0117,4507.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-28",19,18.25,1812.25,,0.005,0.001,934.425,0.058,0.061,0.0097,16017.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-29",20,18.4,1824.78,,0.005,0.001,946.2,0.058,0.066,0.0093,16218.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-30",20,19.39,1907.1,,0.005,0.001,989.426,0.058,0.071,0.0087,16958.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-01-31",3,2.07,109.01,,0,0.001,73.351,0.058,0.009,0.0213,1256.799,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-04",8,7.47,724.45,,0.002,0.001,377.782,0.058,0.027,0.0106,6475.767,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-05",9,8.23,818.07,,0.002,0.001,417.827,0.058,0.025,0.0069,7162.579,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-06",3,2.28,177,,0.001,0.001,108.884,0.058,0.015,0.0153,1865.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-07",7,6.53,609.73,,0.002,0.001,328.595,0.058,0.024,0.0091,5632.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-09",9,8.28,814.88,,0.002,0.001,425.34,0.058,0.031,0.0136,7290.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-10",17,15.8,1556.6,,0.004,0.001,801.6,0.058,0.053,0.0079,13738.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-11",1,0.62,30.38,,0,0.001,26.226,0.058,0.001,0.006,449.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-13",3,2.23,205.68,,0.001,0.001,111.164,0.058,0.01,0.0243,1905.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-14",8,6.32,580.6,,0.002,0.001,311.444,0.058,0.021,0.0098,5338.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-15",3,2.72,236.48,,0.001,0.001,130.104,0.058,0.015,0.0123,2230.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-21",2,1.28,69.48,,0,0.001,56.42,0.058,0.008,0.017,966.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-24",8,6.65,620.9,,0.002,0.001,333.34,0.058,0.022,0.013,5714.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-02",3,1.4,101.73,,0,0.001,63.166,0.0583,0.008,0.017,1082.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-10",4,2.96,249.25,,0.001,0.001,144.204,0.058,0.01,0.0138,2471.421,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-18",7,5.63,519.87,,0.001,0.001,281.924,0.058,0.02,0.0119,4833.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-19",3,1.72,126.4,,0,0.001,78.388,0.058,0.008,0.0113,1343.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-26",7,5.5,519.26,,0.001,0.001,275.558,0.058,0.022,0.0094,4723.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-27",5,4.33,400.25,,0.001,0.001,214.365,0.058,0.018,0.016,3675.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-04",7,6.25,610.5,,0.002,0.001,319.175,0.058,0.022,0.0126,5472.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-05",2,1.22,102.98,,0,0.001,57.256,0.058,0.003,0.0065,981.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-24",11,9.63,927.05,,0.003,0.001,491.979,0.0581,0.034,0.0079,8434.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-25",2,1.13,51.87,,0,0.001,48.195,0.058,0.006,0.016,825.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-01",3,1.87,148.73,,0,0.001,87.865,0.058,0.006,0.0127,1504.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-02",5,3.9,338.6,,0.001,0.001,192.24,0.058,0.015,0.0104,3294.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-05",10,9.15,882.58,,0.002,0.001,464.986,0.058,0.031,0.0078,7969.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-06",7,6.11,553.71,,0.002,0.001,309.359,0.058,0.022,0.0089,5301.501,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-07",3,2.28,177.48,,0.001,0.001,108.032,0.058,0.011,0.0113,1851.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-08",6,5.32,479.68,,0.001,0.001,265.064,0.058,0.021,0.0098,4543.949,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-14",7,6.18,607.16,,0.002,0.001,316.662,0.058,0.021,0.0113,5426.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-15",2,1.7,140.9,,0,0.001,81.63,0.058,0.005,0.007,1399.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-16",7,6.18,561.55,,0.002,0.001,311.493,0.058,0.023,0.0094,5340.163,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-20",4,3.1,266.45,,0.001,0.001,150.6,0.058,0.012,0.0158,2581.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-22",2,1.08,75.6,,0,0.001,47.394,0.058,0.007,0.0115,812.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-27",5,4.28,373.41,,0.001,0.001,213.414,0.058,0.016,0.0104,3657.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-28",3,1.95,164.15,,0,0.001,92.49,0.058,0.009,0.0093,1584.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-02",4,3.25,292.42,,0.001,0.001,159.325,0.058,0.013,0.009,2732.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-03",11,9.92,942.28,,0.003,0.001,505.434,0.058,0.034,0.0083,8661.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-04",8,6.27,602.7,,0.002,0.001,316.394,0.058,0.02,0.0094,5422.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-10",10,8.54,810.86,,0.002,0.001,437.551,0.058,0.03,0.0086,7498.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-11",6,4.53,411.52,,0.001,0.001,226.307,0.058,0.017,0.0108,3877.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-15",6,5.05,485.3,,0.001,0.001,254.188,0.058,0.02,0.008,4356.642,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-23",10,8.47,811.7,,0.002,0.001,433.197,0.058,0.03,0.0089,7428.419,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-26",6,5.07,484.33,,0.001,0.001,255.329,0.058,0.02,0.008,4375.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-09",5,4.39,394.71,,0.001,0.001,221.057,0.058,0.018,0.0092,3789.742,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-10",12,10.32,1003.25,,0.003,0.001,532.458,0.058,0.034,0.009,9126.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-11",11,9.93,965.91,,0.003,0.001,514.075,0.058,0.035,0.0075,8811.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-16",13,12.89,1265.68,,0.003,0.001,668.294,0.058,0.048,0.0084,11454.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-17",10,9.85,955.82,,0.003,0.001,507.294,0.058,0.038,0.0088,8696.263,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-26",9,7.88,743.68,,0.002,0.001,395.976,0.058,0.027,0.008,6786.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-27",7,6.03,576.6,,0.002,0.001,302.627,0.0581,0.022,0.0076,5186.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-28",6,4.18,397,,0.001,0.001,206.772,0.0582,0.017,0.007,3541.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-29",11,9.86,951.04,,0.003,0.001,501.61,0.0581,0.034,0.0076,8596.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-30",10,8.75,840.64,,0.002,0.0009,444.276,0.058,0.031,0.0078,7615.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-07-31",10,9.15,867.02,,0.002,0.001,465.097,0.058,0.033,0.0087,7970.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-01",6,4.32,404.68,,0.001,0.001,215.712,0.058,0.015,0.0092,3695.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-02",4,2.71,229.16,,0.001,0.001,131.8,0.058,0.011,0.009,2258.117,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-03",9,8.05,771.5,,0.002,0.001,406.59,0.058,0.028,0.0077,6969.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-04",8,7.34,681.44,,0.002,0.001,369.092,0.058,0.025,0.0088,6326.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-06",2,1.15,81.52,,0,0.001,50.05,0.058,0.007,0.011,857.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-11",3,1.95,154,,0,0.001,92.015,0.058,0.008,0.0173,1577.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-12",10,9.84,952.14,,0.003,0.001,498.464,0.058,0.034,0.0082,8542.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-13",10,9.05,882.62,,0.002,0.001,459.93,0.058,0.032,0.008,7883.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-14",12,10.31,1009.11,,0.003,0.001,528.542,0.058,0.033,0.0094,9061.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-15",12,11.11,1060.68,,0.003,0.001,561.51,0.058,0.036,0.0099,9623.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-16",9,8.1,792,,0.002,0.001,409.18,0.058,0.03,0.008,7015.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-17",9,8.78,840.56,,0.002,0.001,446.212,0.058,0.031,0.0082,7648.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-18",11,9.69,894.34,,0.002,0.001,481.761,0.058,0.03,0.0081,8257.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-19",9,7.44,706.73,,0.002,0.001,377.701,0.058,0.026,0.0094,6475.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-20",7,6.02,549.64,,0.002,0.001,302.6,0.058,0.021,0.0119,5185.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-21",9,8.05,771.96,,0.002,0.001,405.559,0.058,0.027,0.0073,6951.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-22",10,9.57,912.68,,0.003,0.001,488.803,0.058,0.034,0.0084,8378.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-23",11,9.97,970.3,,0.003,0.001,508.131,0.058,0.033,0.0072,8709.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-24",11,9.22,889.3,,0.002,0.001,463.786,0.058,0.029,0.0077,7951.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-25",10,8.27,797.3,,0.002,0.001,418.846,0.0581,0.027,0.0097,7181.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-26",9,8.85,854,,0.002,0.001,447.02,0.058,0.03,0.0078,7663.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-27",9,7.43,707.15,,0.002,0.001,374.155,0.058,0.024,0.01,6413.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-02",10,8.57,817.4,,0.002,0.001,436.269,0.0581,0.028,0.008,7477.973,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-03",3,1.87,129.28,,0,0.001,85.595,0.058,0.008,0.0137,1466.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-04",8,6.88,639,,0.002,0.001,344.672,0.058,0.021,0.011,5905.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-05",10,9.47,895,,0.002,0.001,480.071,0.058,0.029,0.0076,8228.489,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-06",11,9.27,906.9,,0.002,0.001,468.884,0.0581,0.029,0.0082,8034.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-07",7,5.29,502.53,,0.001,0.001,261.317,0.058,0.015,0.0104,4479.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-11",4,3.27,277.14,,0.001,0.001,164.561,0.058,0.014,0.0113,2820.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-14",2,1.44,49.65,,0,0.001,41.265,0.058,0.004,0.011,707.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-16",8,6.67,624.96,,0.002,0.001,335.267,0.058,0.02,0.0101,5748.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-17",8,6.78,635.7,,0.002,0.001,341.726,0.058,0.023,0.0083,5858.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-18",12,11.03,950.6,,0.003,0.001,504.834,0.0581,0.03,0.0066,8652.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-20",11,10.45,997.07,,0.003,0.001,524.525,0.058,0.037,0.0086,8991.627,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-21",5,4.05,347.24,,0.001,0.001,198.273,0.058,0.014,0.0112,3397.346,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-22",11,9.81,947.18,,0.003,0.001,493.427,0.0581,0.03,0.007,8456.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-23",5,3.83,346.75,,0.001,0.001,186.744,0.0582,0.016,0.0094,3199.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-24",10,8.7,825.6,,0.002,0.001,438.91,0.058,0.025,0.0099,7523.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-25",7,5.75,538.2,,0.001,0.001,285.825,0.058,0.019,0.0077,4899.886,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-28",6,5.52,501.16,,0.001,0.001,272.024,0.058,0.021,0.0098,4661.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-29",6,4.8,444.75,,0.001,0.001,236.865,0.058,0.02,0.0093,4058.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-09-30",7,6.7,638.4,,0.002,0.001,339.375,0.058,0.025,0.009,5817.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-01",8,7.47,697.33,,0.002,0.001,375.822,0.058,0.026,0.0086,6442.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-02",10,8.57,818.1,,0.002,0.001,429.719,0.0581,0.028,0.0084,7366.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-03",11,9.85,944.9,,0.003,0.001,494.315,0.058,0.03,0.0073,8471.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-04",8,7.9,764.45,,0.002,0.001,395.65,0.058,0.025,0.0076,6779.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-05",11,10.05,973.5,,0.003,0.001,507.485,0.058,0.032,0.0072,8699.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-07",9,7.2,700.08,,0.002,0.001,364.24,0.0581,0.027,0.0077,6241.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-08",9,7.17,699.15,,0.002,0.001,358.041,0.058,0.027,0.0071,6137.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-09",5,3.67,327.4,,0.001,0.001,180.863,0.0582,0.014,0.009,3100.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-10",5,3.37,303.5,,0.001,0.001,163.816,0.0582,0.013,0.0136,2808.458,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-11",9,7.37,708.57,,0.002,0.001,368.591,0.058,0.027,0.0081,6319.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-12",5,3.71,328.43,,0.001,0.001,182.964,0.058,0.012,0.0118,3136.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-13",4,2.97,249.04,,0.001,0.001,145.524,0.058,0.012,0.01,2495.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-14",4,3.45,298.67,,0.001,0.001,169.486,0.058,0.014,0.0095,2906.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-15",7,5.9,548.95,,0.002,0.001,296.63,0.058,0.019,0.0109,5085.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-17",4,3.57,308.87,,0.001,0.001,174.959,0.058,0.014,0.0103,2999.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-23",8,7.59,716.38,,0.002,0.001,386.657,0.058,0.028,0.0085,6626.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-25",6,5.01,442.88,,0.001,0.001,248.74,0.058,0.02,0.0113,4263.641,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-10",2,1.44,91.5,,0,0.001,65.032,0.058,0.007,0.013,1114.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-12",3,1.58,116,,0,0.001,71.444,0.058,0.008,0.012,1223.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-19",3,1.52,109.49,,0,0.001,67.411,0.058,0.007,0.0203,1155.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-03",4,2.67,192.78,,0.001,0.001,114.082,0.058,0.01,0.0188,1954.481,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-14",3,1.27,93.75,,0,0.001,51.699,0.0583,0.006,0.013,886.699,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-26",3,1.7,129.53,,0,0.001,77.254,0.0583,0.009,0.0107,1323.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"14",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-10",5,4.8,447.28,,0.001,0.001,238.456,0.058,0.019,0.0094,4087.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-11",9,8.37,802.13,,0.002,0.001,423.343,0.058,0.03,0.0102,7254.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-12",9,7.4,713.6,,0.002,0.001,371.048,0.0581,0.026,0.0112,6360.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-14",8,6.92,657.28,,0.002,0.001,347.306,0.058,0.023,0.0114,5953.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-15",7,6.12,562.15,,0.002,0.001,305.3,0.058,0.023,0.0096,5234.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-17",6,4.15,401.13,,0.001,0.001,205.06,0.0582,0.019,0.0077,3513.353,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-18",10,9.75,962,,0.003,0.001,501.175,0.058,0.038,0.0095,8591.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-19",11,9.73,935.12,,0.003,0.001,494.212,0.058,0.034,0.0088,8471.091,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-20",1,0.28,3.92,,0,0.001,8.232,0.058,0,0.006,141.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-21",5,4.02,385,,0.001,0.001,198.07,0.058,0.019,0.0088,3395.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-23",4,3.37,284.51,,0.001,0.001,165.017,0.058,0.021,0.0168,2828.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-24",6,4.66,425.21,,0.001,0.001,234.004,0.058,0.018,0.0112,4009.556,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-26",4,3.04,251.76,,0.001,0.001,149.128,0.058,0.014,0.0185,2556.556,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-28",8,6.87,638.38,,0.002,0.001,346.457,0.058,0.024,0.0098,5937.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-01-31",8,6.68,624.68,,0.002,0.001,338.636,0.058,0.022,0.012,5805.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-01",6,4.27,369.56,,0.001,0.001,210.376,0.0582,0.016,0.0082,3606.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-03",11,10.31,972.49,,0.003,0.001,523.267,0.058,0.045,0.0112,8969.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-04",18,15.11,1456.16,,0.004,0.001,761.999,0.0581,0.056,0.0103,13062.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-05",18,15.52,1483.51,,0.004,0.001,781.131,0.058,0.051,0.0082,13390.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-06",12,9.87,887.11,,0.003,0.001,487.242,0.058,0.032,0.0112,8351.793,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-07",3,2.4,194.16,,0.001,0.001,117.1,0.058,0.012,0.0157,2007.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-09",4,2.49,213.36,,0.001,0.001,119.398,0.058,0.007,0.0078,2045.273,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-11",6,5.73,543.18,,0.001,0.001,286.364,0.058,0.022,0.0098,4907.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-12",10,6.1,535.6,,0.002,0.001,301.732,0.058,0.022,0.0114,5174.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-13",8,7.73,760.91,,0.002,0.001,397.356,0.058,0.026,0.0083,6811.324,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-14",8,7.63,745.5,,0.002,0.001,389.423,0.058,0.02,0.006,6675.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-16",4,3.17,304.53,,0.001,0.001,160.493,0.058,0.01,0.015,2750.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-17",13,11.17,1061.29,,0.003,0.001,562.229,0.0581,0.034,0.0065,9636.624,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-18",11,8.86,810.81,,0.002,0.001,441.649,0.0581,0.033,0.0089,7568.667,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-19",3,2.4,189.6,,0.001,0.001,116.434,0.058,0.007,0.0067,1994.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-21",7,5.88,555.8,,0.002,0.001,294.434,0.058,0.019,0.0081,5047.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-25",8,6.59,617.88,,0.002,0.001,330.336,0.058,0.023,0.0091,5663.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-27",7,5.8,530.1,,0.001,0.001,290.18,0.058,0.02,0.0126,4971.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-01",5,3.35,306.95,,0.001,0.001,165.56,0.058,0.011,0.0088,2836.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-04",8,7.18,708.98,,0.002,0.001,369.928,0.058,0.022,0.011,6340.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-05",11,9.86,937.58,,0.003,0.001,497.239,0.058,0.028,0.0082,8523.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-06",4,2.85,255.58,,0.001,0.001,141.066,0.058,0.013,0.0078,2418.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-09",6,5.8,557.2,,0.002,0.001,297.04,0.058,0.023,0.01,5090.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-10",1,0.07,0,,0,0.001,0.546,0.059,0,0.001,9.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-12",3,2.93,233.98,,0.001,0.001,129.105,0.058,0.014,0.012,2212.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-13",7,6.72,636.46,,0.002,0.001,340.182,0.058,0.022,0.0079,5831.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-15",4,2.17,193.48,,0.001,0.001,103.141,0.0583,0.009,0.0108,1767.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-16",12,9.49,879.32,,0.002,0.001,474.144,0.058,0.035,0.0107,8126.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-17",5,4.49,412.58,,0.001,0.001,223.707,0.058,0.019,0.0096,3834.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-18",2,1.22,61.68,,0,0.001,54.272,0.058,0.007,0.0145,929.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-19",3,2.07,171.93,,0,0.001,96.651,0.058,0.012,0.0117,1656.369,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-20",8,7.4,721.2,,0.002,0.001,379.28,0.058,0.029,0.0119,6500.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-21",7,6.43,623.47,,0.002,0.001,329.525,0.058,0.02,0.007,5648.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-23",2,1.73,133.21,,0,0.001,80.43,0.058,0.014,0.021,1378.749,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-25",11,9.46,876.01,,0.002,0.001,474.883,0.058,0.043,0.0107,8140.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-26",3,2.12,178.46,,0.001,0.001,101.398,0.058,0.012,0.0117,1736.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-01",4,3.73,351.18,,0.001,0.001,190.929,0.058,0.02,0.0145,3272.773,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-02",14,11.62,1116.82,,0.003,0.001,588.691,0.0581,0.042,0.0084,10091.889,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-04",8,7.1,660.75,,0.002,0.001,358.755,0.058,0.028,0.0101,6147.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-06",13,12.07,1156,,0.003,0.001,607.48,0.058,0.042,0.0082,10412.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-10",4,3.46,293.4,,0.001,0.001,166.998,0.058,0.018,0.014,2862.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-12",7,6.5,630.5,,0.002,0.001,330.7,0.058,0.03,0.0131,5667.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-13",7,6.32,530.2,,0.001,0.001,284.208,0.058,0.019,0.0077,4872.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-20",3,1.54,79.56,,0,0.001,52.656,0.058,0.006,0.015,901.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-27",5,4.1,390.3,,0.001,0.001,203.41,0.058,0.018,0.0122,3486.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-01",2,1.66,125.9,,0,0.001,76.43,0.058,0.01,0.014,1310.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-02",5,4.6,435.2,,0.001,0.001,235.1,0.058,0.022,0.0126,4029.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-03",5,4.33,358.63,,0.001,0.001,210.122,0.058,0.023,0.0134,3601.603,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-07",6,5.12,467.84,,0.001,0.001,256.164,0.058,0.027,0.0128,4392.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-09",8,7.55,732.85,,0.002,0.001,384.37,0.058,0.033,0.0119,6588.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-10",1,0.2,1.2,,0,0.001,4.32,0.058,0,0.004,74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-14",7,6.08,606.08,,0.002,0.001,312.092,0.058,0.026,0.0106,5349.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-15",1,0.35,7.7,,0,0.001,12.145,0.058,0.001,0.008,208.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-16",10,8.32,807.96,,0.002,0.001,423.58,0.058,0.034,0.0099,7259.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-17",5,5,497,,0.001,0.001,258.1,0.058,0.026,0.012,4424.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-18",2,1.03,91,,0,0.001,48.428,0.058,0.003,0.0045,830.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-20",4,2.34,200.76,,0.001,0.001,111.554,0.058,0.016,0.0113,1912.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-23",3,2,159.8,,0,0.001,95.52,0.058,0.017,0.0173,1638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-09",5,2.27,57.59,,0,0.001,71.365,0.058,0.019,0.0316,1222.521,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-01",4,2.89,192.87,,0.001,0.001,118.012,0.058,0.01,0.0108,2023.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-05",5,3.8,343.38,,0.001,0.001,189.208,0.0582,0.02,0.011,3242.678,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-07",10,8.96,863.91,,0.002,0.001,459.404,0.0581,0.035,0.0088,7873.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-09",10,8.29,806.53,,0.002,0.001,425.366,0.0581,0.028,0.0108,7290.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-11",12,10.53,1016.52,,0.003,0.001,544.966,0.058,0.04,0.0105,9338.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-12",9,8.04,775.36,,0.002,0.001,409.976,0.0581,0.03,0.008,7026.808,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-18",4,3.08,251.3,,0.001,0.001,150.48,0.058,0.014,0.0153,2578.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-25",6,5.44,501.81,,0.001,0.001,271.767,0.058,0.022,0.0117,4659.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-07-31",10,9.28,881.4,,0.002,0.001,469.963,0.058,0.036,0.0116,8054.981,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-03",3,1.25,98.05,,0,0.001,55.63,0.058,0.007,0.018,953.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-06",4,3.07,259.93,,0.001,0.001,149.764,0.058,0.01,0.0075,2568.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-08",2,1.9,159.6,,0,0.001,88.928,0.058,0.012,0.016,1524.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-09",4,3.73,334.52,,0.001,0.001,182.259,0.058,0.018,0.0115,3124.263,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-12",9,7.24,701.34,,0.002,0.001,362.776,0.058,0.03,0.0084,6218.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-15",12,10.36,994.45,,0.003,0.001,520.702,0.058,0.036,0.0115,8923.053,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-17",9,7.84,729.14,,0.002,0.001,384.274,0.058,0.033,0.0139,6588.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-18",12,10.79,1015.78,,0.003,0.001,538.536,0.058,0.037,0.0097,9227.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-21",8,7.17,665.93,,0.002,0.001,360.041,0.058,0.034,0.0116,6171.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-24",10,8.68,820.8,,0.002,0.001,436.571,0.058,0.037,0.0087,7484.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-25",9,8.53,808.08,,0.002,0.001,433.072,0.058,0.035,0.0096,7422.018,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-28",8,6.92,661.3,,0.002,0.001,349.699,0.0581,0.028,0.0086,5997.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-02",9,8.03,775.55,,0.002,0.001,407.861,0.058,0.031,0.0086,6990.237,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-06",9,7.4,709.6,,0.002,0.001,370.92,0.058,0.026,0.0126,6354.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-11",4,2.94,248.12,,0.001,0.001,147.562,0.058,0.015,0.0208,2528.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-15",11,9.68,936.53,,0.003,0.001,487.802,0.058,0.033,0.0084,8361.789,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-19",18,16.16,1609,,0.004,0.001,824.623,0.058,0.059,0.0075,14133.589,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-22",10,8.43,812.97,,0.002,0.001,423.622,0.058,0.029,0.0105,7261.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-25",6,4.25,397.4,,0.001,0.001,191.495,0.0582,0.015,0.0157,3281.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-29",7,5.5,514.51,,0.001,0.0009,273.029,0.058,0.025,0.009,4678.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-01",7,6.01,545.18,,0.002,0.001,301.318,0.058,0.025,0.0117,5163.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-05",11,9.7,924.2,,0.003,0.001,489.954,0.058,0.035,0.0105,8396.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-06",9,7.74,724.04,,0.002,0.001,388.872,0.058,0.029,0.0113,6666.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-08",8,7.05,661.1,,0.002,0.001,353.24,0.058,0.031,0.0111,6052.905,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-09",4,3.17,276.27,,0.001,0.001,154.755,0.058,0.016,0.0115,2653.007,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-15",6,5.05,450.03,,0.001,0.001,251.088,0.058,0.022,0.0112,4302.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-17",3,2.24,181.36,,0,0.001,73.444,0.058,0.011,0.027,1259.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-23",12,10.81,1034.39,,0,0.001,85.941,0.0583,0.006,0.0111,1474.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-24",7,5.21,498.78,,0.001,0.001,261.487,0.058,0.021,0.0117,4482.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-26",6,4.4,406.51,,0.001,0.001,219.421,0.058,0.024,0.0102,3761.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-27",13,11.99,1143.69,,0.003,0.001,605.661,0.058,0.045,0.0096,10383.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-28",13,11.94,1171.41,,0.003,0.001,610.108,0.0581,0.042,0.0078,10457.721,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-10-31",4,3.29,279.79,,0.001,0.001,162.263,0.058,0.016,0.0168,2781.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-02",6,5.07,471.84,,0.001,0.001,254.508,0.058,0.021,0.0093,4362.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-03",8,6.36,607.72,,0.002,0.001,322.144,0.058,0.023,0.0098,5522.791,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-04",6,4.63,416.38,,0.001,0.001,231.43,0.058,0.02,0.0143,3966.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-06",5,4.7,429.84,,0.001,0.001,232.364,0.058,0.023,0.013,3982.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-08",4,2.32,201.4,,0.001,0.001,110.24,0.058,0.011,0.0188,1890.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-11",2,1.39,94.18,,0,0.001,62.766,0.058,0.01,0.015,1075.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-12",2,1.13,33.84,,0,0.001,31.703,0.058,0.008,0.0215,544.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-03",5,3.73,284.48,,0.001,0.001,160.539,0.0582,0.016,0.0102,2751.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"15",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-09",16,14.89,1453.43,,0.004,0.001,761.341,0.058,0.05,0.0084,13048.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-12",4,2.92,240.16,,0.001,0.001,141.368,0.058,0.014,0.0133,2423.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-15",2,1.95,172.9,,0,0.001,92.445,0.058,0.013,0.016,1584.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-16",4,3.3,286.9,,0.001,0.001,162,0.058,0.014,0.0155,2776.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-18",9,8.1,804.3,,0.002,0.001,414.93,0.058,0.025,0.0084,7111.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-19",11,9.28,896.55,,0.002,0.001,468.928,0.058,0.029,0.0067,8037.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-20",18,17.8,1763.85,,0.005,0.001,909.125,0.058,0.053,0.0069,15582.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-21",8,7.24,675.28,,0.002,0.001,364.576,0.058,0.025,0.0089,6247.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-22",13,12.6,1221.35,,0.003,0.001,642.745,0.058,0.045,0.0088,11019.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-23",10,9.13,864.24,,0.002,0.001,465.056,0.058,0.03,0.0086,7970.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-24",6,4.55,370.47,,0.001,0.001,221.815,0.058,0.017,0.0095,3801.907,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-25",8,7.42,726.12,,0.002,0.001,384.42,0.058,0.025,0.0101,6588.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-26",9,7.58,687.92,,0.002,0.001,380.89,0.058,0.025,0.008,6527.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-27",10,9.44,894.55,,0.002,0.001,476.241,0.058,0.039,0.0111,8162.053,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-28",19,17.78,1758.71,,0.005,0.001,913.955,0.058,0.052,0.0082,15663.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-29",11,8.57,747.3,,0.002,0.001,422.974,0.058,0.032,0.0135,7251.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-30",11,8.85,801.28,,0.002,0.001,441.441,0.058,0.031,0.0146,7567.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-01-31",19,17.84,1759.44,,0.005,0.001,916.791,0.0581,0.064,0.0083,15709.849,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-01",7,6.14,558.58,,0.002,0.001,309.416,0.058,0.023,0.01,5303.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-03",12,10.3,964.99,,0.003,0.001,523.548,0.058,0.049,0.0196,8973.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-04",7,5.97,518.4,,0.001,0.001,290.913,0.058,0.026,0.0129,4987.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-06",6,5.78,561.16,,0.002,0.001,295.728,0.058,0.022,0.0093,5069.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-07",14,11.34,1094.54,,0.003,0.001,573.381,0.058,0.04,0.0076,9826.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-08",1,0.83,58.93,,0,0.001,37.184,0.058,0.002,0.007,637.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-09",11,9.91,964.9,,0.003,0.001,502.303,0.058,0.049,0.0108,8607.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-10",17,15.5,1532.7,,0.004,0.001,790.214,0.058,0.053,0.0094,13541.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-11",16,14.96,1463.1,,0.004,0.001,758.766,0.058,0.05,0.0078,13006.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-12",9,6.46,590.63,,0.002,0.001,322.169,0.058,0.027,0.0106,5522.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-13",17,16.18,1608.85,,0.004,0.001,830.69,0.058,0.053,0.0075,14237.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-14",16,14.7,1437.64,,0.004,0.001,753.864,0.058,0.042,0.0077,12921.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-15",16,15.3,1493.88,,0.004,0.001,782.872,0.058,0.043,0.0071,13419.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-16",2,1.48,117.8,,0,0.001,71.1,0.058,0.004,0.0065,1218.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-17",11,8.87,847.1,,0.002,0.001,446.899,0.058,0.038,0.0094,7658.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-18",9,8.07,652,,0.002,0.001,354.339,0.058,0.02,0.0059,6071.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-21",5,3.75,339.52,,0.001,0.001,184.432,0.058,0.017,0.0096,3162.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-22",3,2.23,165.52,,0.001,0.001,106.146,0.058,0.012,0.0143,1818.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-23",3,2.74,234.26,,0.001,0.001,131.976,0.058,0.015,0.0143,2261.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-24",3,1.98,161.1,,0,0.001,92.8,0.058,0.013,0.0133,1591.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-25",7,6.12,572.93,,0.002,0.001,307.379,0.058,0.023,0.009,5266.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-26",3,2.05,164.8,,0,0.001,96.801,0.058,0.014,0.015,1659.531,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-27",5,4.73,437.51,,0.001,0.001,235.318,0.058,0.019,0.0096,4033.615,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-02-29",4,3.07,289.07,,0.001,0.001,151.966,0.058,0.011,0.009,2605.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-03",7,6.85,674,,0.002,0.001,353.28,0.058,0.026,0.0089,6054.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-04",2,0.87,19.41,,0,0.001,20.799,0.058,0.003,0.0105,356.513,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-05",7,6.13,566.25,,0.002,0.001,310.05,0.058,0.022,0.0087,5314.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-06",3,2.2,171.2,,0.001,0.001,106.431,0.058,0.014,0.0257,1823.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-09",2,1.75,136.83,,0,0.001,81.429,0.058,0.013,0.0185,1395.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-10",2,1.17,60.75,,0,0.001,51.885,0.058,0.008,0.0155,889.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-15",4,2.93,248.87,,0.001,0.001,143.337,0.058,0.014,0.0113,2456.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-16",13,10.86,1003.74,,0.003,0.001,546.785,0.058,0.045,0.0104,9371.553,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-18",3,2.2,162.42,,0.001,0.001,105.348,0.058,0.012,0.0167,1804.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-20",7,6.17,606.53,,0.002,0.001,315.657,0.058,0.019,0.012,5410.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-21",8,7.07,703,,0.002,0.001,362.239,0.058,0.021,0.0063,6209.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-25",8,7.32,714,,0.002,0.001,375.748,0.058,0.028,0.0131,6441.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-26",1,0.12,0,,0,0.001,0.948,0.058,0,0.002,16.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-03-31",3,1.95,136.56,,0,0.001,90.801,0.058,0.01,0.0143,1556.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-02",7,6.22,570.38,,0.002,0.001,314.667,0.058,0.025,0.0116,5393.877,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-04",6,6,600,,0.002,0.001,308.1,0.058,0.026,0.0102,5279.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-05",7,6.38,615.5,,0.002,0.001,326.884,0.058,0.022,0.008,5602.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-07",3,2.1,182.42,,0.001,0.001,99.24,0.0583,0.011,0.0103,1699.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-12",8,7.11,662.42,,0.002,0.001,357.512,0.058,0.026,0.0105,6127.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-20",2,1.33,78.43,,0,0.001,60.606,0.058,0.007,0.014,1039.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-27",5,4.08,390.16,,0.001,0.001,203.268,0.058,0.016,0.0104,3484.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-01",2,1.38,81.52,,0,0.001,62.638,0.058,0.007,0.013,1072.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-02",7,6.9,680.6,,0.002,0.001,354.52,0.058,0.027,0.009,6077.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-03",2,1.93,175.4,,0,0.001,94.308,0.058,0.006,0.007,1616.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-06",5,4.34,390.96,,0.001,0.001,217.414,0.058,0.018,0.0096,3727.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-23",4,2.78,233.74,,0.001,0.001,137.114,0.058,0.01,0.0085,2350.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-15",6,5.23,496.91,,0.001,0.001,263.766,0.058,0.019,0.0083,4522.451,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-16",6,4.22,399.48,,0.001,0.001,211.682,0.058,0.013,0.0095,3627.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-07",5,4.4,384.77,,0.001,0.001,221.028,0.058,0.019,0.0106,3787.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-24",16,15.19,1496.06,,0.004,0.001,777.22,0.058,0.05,0.0074,13318.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-09",2,1.04,72.36,,0,0.001,44.724,0.058,0.003,0.0175,765.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-15",9,7.93,766.7,,0.002,0.001,397.338,0.058,0.026,0.0071,6807.077,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-19",11,10.18,983.4,,0.003,0.001,512.402,0.058,0.028,0.0086,8783.259,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-15",6,4.95,443.5,,0.001,0.001,247.03,0.058,0.016,0.0085,4232.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-12",2,1.23,65.39,,0,0.001,54.614,0.058,0.007,0.0135,936.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-18",4,2.82,133.29,,0,0.001,90.326,0.058,0.008,0.0093,1548.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-03",4,2.91,225.04,,0.001,0.001,122.372,0.058,0.013,0.0093,2097.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"16",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-23",4,3.73,0,,0,0.001,29.286,0.0588,0.006,0.023,500.573,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-24",24,24,2572,,0.008,0.001,1535.1,0.058,0.061,0.0093,26310.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-25",21,18.93,1185,,0.004,0.001,797.091,0.058,0.038,0.0149,13659.121,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-26",24,23.23,1784.16,,0.006,0.001,1118.09,0.058,0.038,0.0043,19164.857,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-22",6,5.05,0,,0,0.001,38.92,0.0583,0.01,0.026,666.39,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-23",24,24,835,,0.003,0.001,652,0.0581,0.016,0.0072,11178.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-24",24,23.95,1714.2,,0.006,0.001,1100.575,0.058,0.019,0.0019,18867.725,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-25",24,24,1538,,0.005,0.001,984.4,0.058,0.003,0.0002,16873.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-26",24,24,1966,,0.006,0.001,1231.4,0.058,0.011,0.0005,21105.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-27",24,24,2019,,0.006,0.001,1231.7,0.058,0.015,0.0013,21110.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-28",24,24,2920,,0.009,0.001,1746.3,0.058,0.041,0.0018,29932.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-29",24,24,1205,,0.004,0.001,814.2,0.058,0,0,13955.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-04-30",24,24,1312,,0.004,0.001,864.8,0.058,0,0,14820.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-01",20,19.73,1122.73,,0.004,0.001,738.026,0.058,0.002,0.0001,12654.753,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-28",4,3.07,0,,0,0.001,24.081,0.058,0.001,0.0035,412.882,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-29",24,24,2079,,0.007,0.001,1306.5,0.058,0.084,0.012,22391.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-06-30",24,24,2152,,0.007,0.001,1328.7,0.058,0.018,0.0009,22768.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-01",22,21.58,1085.54,,0.004,0.001,744.56,0.058,0,0,12764.006,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-08",12,11.63,16,,0.001,0.001,113.34,0.058,0.019,0.0193,1943.688,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-09",24,24,1547,,0.005,0.001,1028.1,0.058,0.027,0.0035,17620.1,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-10",24,24,2156,,0.007,0.001,1388.2,0.058,0.029,0.0027,23791.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-11",24,24,1372,,0.005,0.001,929.4,0.058,0.022,0.0021,15935.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-12",8,7.88,352.54,,0.001,0.001,266.434,0.058,0.004,0.0018,4566.656,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-13",7,6.93,0,,0,0.001,49.468,0.0583,0.006,0.0153,847.33,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-14",16,15.4,607.8,,0.002,0.001,483.42,0.0581,0.025,0.0137,8284.46,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-15",7,6.6,0,,0,0.001,55.88,0.0586,0.013,0.0214,957.08,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-16",24,24,1377,,0.005,0.001,960.7,0.058,0.032,0.006,16464.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-17",24,24,1526,,0.005,0.001,990.3,0.058,0.024,0.0028,16976.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-18",24,24,1221,,0.004,0.001,829.5,0.058,0.015,0.0021,14223.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-19",24,24,1497,,0.005,0.001,977.7,0.058,0.003,0.0005,16756.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-20",24,24,1364,,0.005,0.001,901.4,0.058,0.007,0.0008,15447.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-21",15,14.95,896.35,,0.003,0.001,599.655,0.058,0.014,0.0022,10276.45,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-06",24,23.45,757,,0.003,0.001,605.41,0.0582,0.068,0.0218,10375.475,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-07",24,24,1290,,0.004,0.001,850.3,0.058,0,0,14571.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-08",24,24,1184,,0.004,0.001,797.3,0.058,0.002,0.0003,13664.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-09",24,24,1530,,0.005,0.001,978.1,0.058,0.01,0.0009,16763.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-10",15,14.82,734.24,,0.003,0.001,498.02,0.058,0,0.0001,8535.136,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-11",6,5.85,0,,0,0.001,36.925,0.0582,0,0.0012,633.885,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-12",24,24,1176,,0.004,0.001,817.4,0.0581,0.018,0.0035,14007.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-13",24,24,1672,,0.005,0.001,1059.7,0.058,0.018,0.0018,18167,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-14",24,24,2104,,0.007,0.001,1285,0.058,0.014,0.0011,22024.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-15",24,24,2349,,0.007,0.001,1405.6,0.058,0.033,0.002,24091.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-16",24,24,2168,,0.007,0.001,1320.5,0.058,0.027,0.0014,22632.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-17",24,24,2108,,0.007,0.001,1294.5,0.058,0.022,0.001,22185.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-18",21,20.35,2077.9,,0.006,0.001,1239.175,0.058,0.011,0.0006,21238.87,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-20",17,16.15,845,,0.003,0.001,572.12,0.0581,0.027,0.0114,9805.68,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-21",24,24,1848,,0.006,0.001,1139.7,0.058,0.014,0.0011,19536.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-22",24,24,2260,,0.007,0.001,1356.6,0.058,0.029,0.002,23249.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-23",24,23.95,2108.05,,0.007,0.001,1280.7,0.058,0.015,0.001,21952.48,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-24",24,24,1908,,0.006,0.001,1168,0.058,0.013,0.001,20019.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-25",24,24,1651,,0.005,0.001,1045.6,0.058,0.002,0.0002,17922.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-26",24,24,1417,,0.005,0.001,934.5,0.058,0,0,16015.8,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-27",24,24,1402,,0.005,0.001,928.2,0.058,0,0,15910.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-28",24,24,1639,,0.005,0.001,1031.3,0.058,0.008,0.0008,17671.5,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-29",24,24,1806,,0.006,0.001,1122.5,0.058,0.007,0.0005,19237.6,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-09-30",24,23.87,1770.5,,0.006,0.001,1108.691,0.058,0.014,0.0011,19001.745,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-01",24,24,1667,,0.005,0.001,1040.7,0.058,0.011,0.0011,17839.4,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-02",24,24,1864,,0.006,0.001,1154.6,0.058,0.01,0.0007,19793.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-03",24,24,1986,,0.006,0.001,1220.2,0.058,0.008,0.0005,20914.9,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-04",24,24,1754,,0.006,0.001,1097.7,0.058,0.022,0.0022,18819.7,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-05",24,24,2117,,0.007,0.001,1283.1,0.058,0.02,0.0016,21992.3,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-06",21,20.02,1842,,0.006,0.001,1111.644,0.058,0.035,0.0032,19057.462,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-02",2,0.17,0,,0,0.001,1.095,0.058,0,0,18.834,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-09",2,0.05,0,,0,0.001,0.164,0.059,0,0.02,2.78,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-03",16,15.5,246,,0.001,0.001,276.9,0.0582,0.044,0.0248,4747.2,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-04",19,18.27,956.43,,0.003,0.001,655.711,0.058,0.018,0.003,11240.816,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-01",16,15.65,3816.54,,0.008,0.001,1540.976,0.058,0.098,0.0091,26411.354,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-02",24,24,5544,,0.011,0.001,2230.3,0.058,0.115,0.006,38225.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-03",19,18.22,4403.28,,0.009,0.001,1769.197,0.058,0.115,0.0098,30325.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-04",24,24,5525,,0.011,0.001,2234.8,0.058,0.115,0.006,38301.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-05",19,18.57,4368.15,,0.009,0.001,1766.956,0.058,0.12,0.0102,30288.476,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-06",24,24,5680,,0.012,0.001,2297.2,0.058,0.118,0.006,39375.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-07",11,10.17,2360.26,,0.005,0.001,974.752,0.058,0.093,0.0205,16706.244,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-08",24,24,5836,,0.012,0.001,2340.3,0.058,0.12,0.006,40112.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-09",10,9.67,2409.33,,0.005,0.001,969.643,0.058,0.051,0.0064,16618.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-10",11,10.43,2481.45,,0.005,0.001,1007.387,0.058,0.095,0.0244,17266.157,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-11",24,24,5801,,0.012,0.001,2330.6,0.058,0.12,0.006,39946.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-12",20,19.64,4865.62,,0.01,0.001,1956.417,0.058,0.118,0.009,33531.695,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-13",24,24,6075,,0.013,0.001,2433.5,0.058,0.124,0.006,41712.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-14",24,24,5810,,0.012,0.001,2345.7,0.058,0.121,0.006,40207.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-15",24,24,6510,,0.013,0.001,2587.2,0.058,0.133,0.006,44345.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-16",24,24,6588,,0.014,0.001,2629.7,0.058,0.135,0.006,45073,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-17",24,24,6352,,0.013,0.001,2514.1,0.058,0.129,0.006,43092.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-18",24,24,6089,,0.012,0.001,2427.6,0.058,0.125,0.006,41604.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-19",24,23.98,6127.7,,0.013,0.001,2444.472,0.058,0.125,0.006,41894.628,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-20",24,24,6352,,0.013,0.001,2509.6,0.058,0.129,0.006,43017.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-21",24,24,6346,,0.013,0.001,2509.1,0.058,0.129,0.006,43007,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-22",24,24,6175,,0.013,0.001,2455.5,0.058,0.126,0.006,42089.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-23",24,24,6218,,0.013,0.001,2470.4,0.058,0.126,0.006,42335.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-24",24,24,5846,,0.012,0.001,2357.2,0.058,0.121,0.006,40402.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-25",19,18.36,4419.53,,0.009,0.001,1797.306,0.058,0.108,0.0086,30804.765,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-26",24,24,5714,,0.012,0.001,2314,0.058,0.119,0.006,39659.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-27",21,20.47,5033.97,,0.01,0.001,2034.031,0.058,0.122,0.0083,34866.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-28",24,24,6016,,0.012,0.001,2412,0.058,0.122,0.0059,41341.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-29",20,19.71,4840.05,,0.01,0.001,1954.462,0.058,0.122,0.009,33499.967,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-30",24,24,6040,,0.012,0.001,2416.4,0.058,0.124,0.006,41413.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-01-31",20,18.99,4797.48,,0.01,0.001,1933.408,0.058,0.117,0.0086,33139.587,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-01",24,24,5756,,0.012,0.001,2298.9,0.058,0.118,0.006,39400.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-02",19,17.58,3996.05,,0.008,0.001,1650.824,0.058,0.114,0.0099,28294.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-03",22,21.27,5148.52,,0.011,0.001,2097.355,0.058,0.134,0.01,35948.953,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-04",24,24,6189,,0.013,0.001,2485.4,0.058,0.128,0.006,42599.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-05",24,24,6051,,0.012,0.001,2406.3,0.058,0.123,0.006,41246.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-06",24,24,6009,,0.012,0.001,2411.8,0.058,0.124,0.006,41334.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-07",24,24,6202,,0.013,0.001,2471.6,0.058,0.127,0.006,42365.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-08",18,16.9,3943.89,,0.008,0.001,1607.487,0.058,0.099,0.0081,27551.581,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-09",21,19.29,4988.88,,0.01,0.001,2021.839,0.058,0.123,0.0079,34652.819,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-10",21,19.9,5268.18,,0.011,0.001,2160.503,0.058,0.126,0.0082,37033.158,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-11",24,24,6285,,0.013,0.001,2511.7,0.058,0.129,0.006,43049,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-12",24,23.86,6003.02,,0.012,0.001,2429.652,0.058,0.125,0.006,41646.134,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-13",24,24,6185,,0.013,0.001,2483.9,0.058,0.128,0.006,42574.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-14",21,19.92,4808.85,,0.01,0.001,1948.982,0.058,0.118,0.0095,33407.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-15",24,24,5884,,0.012,0.001,2370.1,0.058,0.122,0.006,40625.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-16",18,16.3,3853.75,,0.008,0.001,1565.253,0.058,0.107,0.0101,26826.718,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-17",24,24,5920,,0.012,0.001,2383.8,0.058,0.123,0.006,40855.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-18",24,24,6028,,0.013,0.001,2437.4,0.058,0.125,0.006,41777.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-19",24,24,5830,,0.012,0.001,2345,0.058,0.121,0.006,40196.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-20",24,23.98,5764.76,,0.012,0.001,2318.874,0.058,0.117,0.0059,39745.352,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-21",24,23.98,5735.42,,0.012,0.001,2305.386,0.058,0.119,0.006,39513.254,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-22",24,24,6134,,0.013,0.001,2441.6,0.058,0.126,0.006,41851.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-23",8,7.77,1940.17,,0.004,0.001,786.821,0.058,0.042,0.0065,13486.834,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-24",9,8.92,2066.56,,0.004,0.001,846.748,0.058,0.095,0.0227,14513.276,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-25",24,24,6182,,0.013,0.001,2474.4,0.058,0.127,0.006,42414.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-26",24,24,6009,,0.012,0.001,2392.6,0.058,0.123,0.006,41008.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-27",24,23.98,6103.16,,0.013,0.001,2441.218,0.058,0.126,0.006,41838.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-28",24,24,6352,,0.013,0.001,2543.2,0.058,0.13,0.006,43591,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-02-29",24,24,5223,,0.011,0.001,2131.3,0.058,0.11,0.006,36528.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-01",15,13.77,2839.77,,0.006,0.001,1200.027,0.058,0.085,0.0105,20571.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-06",11,9.53,2094.69,,0.004,0.001,874.622,0.058,0.103,0.028,14990.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-07",24,24,6043,,0.013,0.001,2451.9,0.058,0.126,0.006,42027.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-08",16,15.4,3553.22,,0.008,0.001,1466.788,0.058,0.097,0.0106,25141.226,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-09",24,24,5756,,0.012,0.001,2374.9,0.058,0.122,0.006,40705.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-10",24,24,6056,,0.013,0.001,2476.4,0.058,0.126,0.006,42446.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-11",24,24,5585,,0.012,0.001,2262.5,0.058,0.115,0.006,38778.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-12",24,24,6166,,0.013,0.001,2458.3,0.058,0.126,0.006,42136.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-13",24,24,6168,,0.013,0.001,2475.4,0.058,0.127,0.006,42430.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-14",24,23.9,5438.48,,0.011,0.001,2226.614,0.058,0.114,0.006,38166.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-15",24,24,5274,,0.011,0.001,2182.4,0.058,0.112,0.006,37404,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-16",24,24,6423,,0.013,0.001,2572.5,0.058,0.131,0.006,44095,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-17",17,16.05,3988.2,,0.008,0.001,1629.125,0.058,0.117,0.0118,27921.275,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-18",24,24,6000,,0.012,0.001,2414.6,0.058,0.123,0.006,41386.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-19",17,16.25,3732.6,,0.008,0.001,1539.595,0.058,0.115,0.0132,26387.615,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-20",24,24,5835,,0.012,0.001,2388.8,0.058,0.122,0.006,40941.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-21",24,24,6115,,0.013,0.001,2476,0.058,0.127,0.006,42442.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-22",21,19.78,4530.54,,0.01,0.001,1891.456,0.058,0.121,0.0099,32420.808,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-23",24,24,5821,,0.012,0.001,2375.1,0.058,0.122,0.006,40706.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-24",24,24,5356,,0.011,0.001,2220.3,0.058,0.114,0.006,38054.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-25",9,8.15,1978.9,,0.004,0.001,800.805,0.058,0.042,0.0067,13728.155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-02",2,1.02,28.3,,0,0.001,34.394,0.058,0.038,0.0925,589.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-08",13,12.13,2764.26,,0.006,0.001,1135.075,0.058,0.096,0.0191,19453.722,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-09",24,23.74,6370.83,,0.013,0.001,2568.29,0.058,0.131,0.006,44024.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-10",24,23.98,6182.74,,0.013,0.001,2472.158,0.058,0.126,0.006,42372.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-11",17,15.32,3706.32,,0.008,0.001,1495.716,0.058,0.11,0.0107,25637.868,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-12",16,15.55,3753.75,,0.008,0.001,1533.225,0.058,0.08,0.0063,26280.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-15",7,6.87,1413.58,,0.003,0.001,597.328,0.058,0.105,0.0404,10237.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-16",3,2.27,395.21,,0.001,0.001,172.478,0.058,0.01,0.0087,2957.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-20",9,8.4,1825.8,,0.004,0.001,753.4,0.058,0.089,0.0291,12912.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-21",7,7,1690,,0.003,0.001,675.4,0.058,0.037,0.0064,11576.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-23",8,7,1377.04,,0.003,0.001,582.63,0.058,0.086,0.0321,9986.438,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-24",12,11.12,2645.12,,0.005,0.001,1066.128,0.0581,0.083,0.0115,18273.732,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-25",20,19.78,4808.6,,0.01,0.001,1929.712,0.058,0.113,0.0081,33073.507,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-26",21,19.12,4704,,0.01,0.001,1911.561,0.058,0.113,0.0074,32766.111,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-27",20,19.03,4672.8,,0.01,0.001,1908.947,0.058,0.117,0.009,32719.219,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-28",15,13.72,3417.76,,0.007,0.001,1394.9,0.058,0.096,0.0121,23907.912,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-29",24,23.63,5446.07,,0.011,0.001,2199.589,0.058,0.112,0.006,37701.109,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-04-30",9,8.73,1959.82,,0.004,0.001,799.81,0.058,0.071,0.0178,13709.658,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-01",20,19.16,4587.85,,0.01,0.001,1858.425,0.058,0.115,0.0094,31850.466,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-02",13,11.63,2604.19,,0.006,0.001,1086.818,0.058,0.078,0.0112,18629.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-03",7,6.95,1474.5,,0.003,0.001,615.49,0.058,0.081,0.0246,10549.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-04",21,19.79,4393.9,,0.009,0.001,1818.263,0.058,0.111,0.0081,31167.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-05",20,18.78,4674.27,,0.01,0.001,1914.186,0.058,0.111,0.0089,32809.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-06",24,24,5768,,0.012,0.001,2334.8,0.058,0.117,0.0058,40021,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-07",24,24,5505,,0.012,0.001,2247.8,0.058,0.114,0.0059,38529.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-08",20,19.02,4665.86,,0.01,0.001,1911.43,0.058,0.116,0.0089,32755.943,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-09",19,17.95,4290.24,,0.009,0.001,1756.413,0.058,0.111,0.0097,30104.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-10",7,6.3,1407.3,,0.003,0.001,576.51,0.058,0.031,0.0071,9880.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-14",9,8.42,1833.04,,0.004,0.001,775.296,0.058,0.107,0.0354,13288.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-15",24,24,5803,,0.012,0.001,2333,0.058,0.118,0.0059,39986.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-16",13,12.5,2674,,0.006,0.001,1116.2,0.058,0.088,0.0145,19130.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-17",6,5.93,1279.5,,0.003,0.001,521.547,0.058,0.028,0.0065,8937.134,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-21",10,9.4,2010.8,,0.004,0.001,841.9,0.058,0.121,0.0374,14430.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-22",16,15.25,3197.25,,0.007,0.001,1335.055,0.058,0.09,0.0112,22882.914,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-23",11,10.57,2427.48,,0.005,0.001,1007.883,0.058,0.09,0.0171,17277.946,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-24",17,16.35,3884.85,,0.008,0.001,1580.98,0.058,0.1,0.0098,27099.125,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-25",18,17.72,4286.44,,0.009,0.001,1753.516,0.058,0.107,0.0091,30060.552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-26",23,22.12,5467.78,,0.011,0.001,2232.86,0.058,0.134,0.0075,38275.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-27",24,24,5949,,0.012,0.001,2420.6,0.058,0.124,0.006,41491.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-28",24,23.97,5877.54,,0.012,0.001,2399.233,0.058,0.123,0.006,41122.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-29",24,23.98,5892.38,,0.012,0.001,2371.006,0.058,0.122,0.006,40635.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-30",16,13.57,2820,,0.006,0.001,1170.14,0.058,0.077,0.0086,20054.287,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-08",8,7.4,1589.8,,0.003,0.001,676,0.058,0.11,0.0413,11587.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-09",24,24,6081,,0.013,0.001,2460.8,0.058,0.127,0.006,42179.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-10",24,24,5372,,0.011,0.001,2220.9,0.058,0.115,0.006,38064.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-11",24,24,5775,,0.012,0.001,2362.2,0.058,0.121,0.006,40489.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-12",24,24,5986,,0.012,0.001,2401.3,0.058,0.123,0.006,41157.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-13",21,19.99,4310.29,,0.009,0.001,1804.176,0.058,0.124,0.0093,30923.448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-14",14,13.28,3084,,0.007,0.001,1274.725,0.058,0.089,0.0129,21847.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-15",24,24,5567,,0.012,0.001,2275.5,0.058,0.117,0.006,38997.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-16",24,24,5734,,0.012,0.001,2327.5,0.058,0.117,0.0059,39894.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-17",24,24,5612,,0.012,0.001,2278.6,0.058,0.116,0.0059,39059.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-18",24,24,5397,,0.011,0.001,2195.8,0.058,0.111,0.0059,37640.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-19",22,21.18,4599.62,,0.01,0.001,1885.468,0.058,0.095,0.006,32320.866,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-20",9,8.97,2099.11,,0.004,0.001,861.807,0.058,0.075,0.0156,14772.024,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-21",7,6.43,1131.21,,0.003,0.001,491.018,0.058,0.026,0.0071,8417.316,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-22",14,13.35,3288.5,,0.007,0.001,1380.43,0.058,0.101,0.0166,23660.97,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-23",24,24,5455,,0.012,0.001,2264.3,0.058,0.116,0.006,38812.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-24",20,19.25,3904.3,,0.009,0.001,1660.264,0.058,0.107,0.0096,28458.693,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-25",24,24,5668,,0.012,0.001,2326.9,0.058,0.12,0.006,39881.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-26",24,24,5939,,0.012,0.001,2383.8,0.058,0.121,0.0059,40860,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-27",24,24,5599,,0.012,0.001,2283.6,0.058,0.115,0.0059,39138.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-28",19,17.65,3768.54,,0.008,0.001,1576.732,0.058,0.108,0.0109,27025.254,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-29",6,5.67,1138.98,,0.003,0.001,489.645,0.058,0.025,0.0058,8392.263,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-03",14,12.88,2747.08,,0.006,0.001,1152.708,0.058,0.11,0.0234,19757.713,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-04",13,12.27,2463.28,,0.005,0.001,1065.416,0.058,0.214,0.0388,18261.781,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-05",14,13.37,3111.22,,0.007,0.001,1302.481,0.058,0.092,0.0144,22323.942,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-06",11,9.5,2111.3,,0.005,0.001,877.575,0.058,0.103,0.022,15042.495,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-07",24,24,5719,,0.012,0.001,2330.9,0.058,0.118,0.0059,39952.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-08",24,23.95,5882.85,,0.012,0.001,2393.795,0.058,0.122,0.006,41027.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-09",24,24,5737,,0.012,0.001,2358.9,0.058,0.12,0.0059,40430.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-10",24,24,6089,,0.013,0.001,2506.6,0.058,0.13,0.006,42962.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-11",24,24,5740,,0.012,0.001,2371.7,0.058,0.121,0.006,40650,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-12",24,23.98,5981.94,,0.013,0.001,2454.626,0.058,0.125,0.006,42071.048,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-13",24,24,5634,,0.012,0.001,2306.8,0.058,0.117,0.0059,39538.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-14",24,23.98,5400.54,,0.011,0.001,2236.268,0.058,0.112,0.0058,38328.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-15",24,24,5485,,0.012,0.001,2250.1,0.058,0.116,0.006,38567,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-16",17,15.93,3539.23,,0.008,0.001,1467.627,0.058,0.097,0.0114,25154.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-17",24,24,5654,,0.012,0.001,2319.3,0.058,0.119,0.006,39755.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-18",24,24,5572,,0.012,0.001,2277,0.058,0.117,0.006,39024.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-19",21,19.79,4454.43,,0.009,0.001,1838.009,0.058,0.108,0.0076,31502.125,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-20",23,22.18,5388.8,,0.011,0.001,2188.51,0.058,0.112,0.0062,37509.516,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-21",13,12.07,3041,,0.006,0.001,1233.944,0.058,0.088,0.0102,21151.081,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-22",24,24,5234,,0.011,0.001,2110,0.058,0.108,0.006,36166,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-23",24,24,5961,,0.012,0.001,2350.5,0.058,0.12,0.006,40283.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-24",24,24,5707,,0.012,0.001,2271.2,0.058,0.117,0.006,38931.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-25",24,24,5368,,0.011,0.001,2174.2,0.058,0.11,0.0059,37269.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-26",14,13.07,3045.25,,0.006,0.001,1258.037,0.058,0.086,0.0136,21563.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-27",24,24,6172,,0.013,0.001,2486.6,0.058,0.125,0.0059,42622.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-28",24,24,5554,,0.011,0.001,2223.5,0.058,0.111,0.0058,38116,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-29",24,24,5673,,0.012,0.001,2257.9,0.058,0.114,0.0059,38699.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-30",24,24,5585,,0.012,0.001,2255.7,0.058,0.114,0.0059,38662,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-07-31",24,24,5823,,0.012,0.001,2362.2,0.058,0.119,0.0059,40489.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-01",24,24,5735,,0.012,0.001,2335.3,0.058,0.118,0.0059,40026.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-02",24,24,5577,,0.012,0.001,2261.9,0.058,0.115,0.006,38770.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-03",24,24,5744,,0.012,0.001,2328.1,0.058,0.118,0.0059,39901.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-04",24,23.15,5801.75,,0.012,0.001,2296.98,0.058,0.118,0.0061,39372.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-05",11,10.83,2478.18,,0.005,0.001,1010.653,0.058,0.076,0.0133,17321.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-06",24,24,5611,,0.012,0.001,2282,0.058,0.117,0.006,39117.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-07",24,24,5462,,0.011,0.001,2197,0.058,0.113,0.006,37659.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-08",24,24,5700,,0.012,0.001,2305.2,0.058,0.119,0.006,39515.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-09",18,17.3,4043.58,,0.008,0.001,1634.252,0.058,0.102,0.0097,28009.302,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-10",24,24,5755,,0.012,0.001,2322,0.058,0.119,0.006,39799.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-11",24,24,5480,,0.011,0.001,2226.7,0.058,0.115,0.006,38167.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-12",24,24,5707,,0.012,0.001,2298.3,0.058,0.117,0.006,39392.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-13",24,24,5965,,0.012,0.001,2363,0.058,0.12,0.0059,40501.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-14",24,24,6260,,0.013,0.001,2502.5,0.058,0.128,0.006,42890.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-15",24,24,5785,,0.012,0.001,2328.2,0.058,0.116,0.0058,39907.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-16",24,24,5306,,0.011,0.001,2168.1,0.058,0.111,0.006,37164.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-17",23,22.55,4944.65,,0.011,0.001,2048.81,0.058,0.106,0.0061,35114.825,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-18",23,22.13,5076,,0.011,0.001,2114.54,0.058,0.135,0.0088,36248.796,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-19",24,24,5266,,0.011,0.001,2165.5,0.058,0.111,0.006,37116.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-20",24,24,5009,,0.01,0.001,2041.3,0.058,0.104,0.0059,34991.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-21",24,24,5431,,0.011,0.001,2182.5,0.058,0.112,0.006,37409.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-22",24,24,5853,,0.012,0.001,2334.7,0.058,0.12,0.006,40015.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-23",24,24,5866,,0.012,0.001,2343.5,0.058,0.121,0.006,40167.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-24",24,24,5895,,0.012,0.001,2356.5,0.058,0.121,0.006,40389.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-25",24,24,5773,,0.012,0.001,2306.7,0.058,0.118,0.006,39537.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-26",24,23.93,5494.78,,0.011,0.001,2212.657,0.058,0.112,0.0059,37928.326,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-27",24,24,5319,,0.011,0.001,2140.1,0.058,0.109,0.006,36682.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-28",24,24,5427,,0.011,0.001,2180.4,0.058,0.111,0.006,37373.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-29",24,23.98,5023.94,,0.011,0.001,2043.556,0.058,0.105,0.006,35026.382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-30",24,24,4986,,0.01,0.001,2028.6,0.058,0.103,0.006,34773.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-08-31",24,24,6088,,0.012,0.001,2403.5,0.058,0.124,0.006,41195.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-01",24,24,5838,,0.012,0.001,2315.2,0.058,0.119,0.006,39681.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-02",24,24,5816,,0.012,0.001,2316.4,0.058,0.117,0.0059,39706.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-03",24,24,5716,,0.012,0.001,2272.1,0.058,0.117,0.006,38949.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-04",24,24,5912,,0.012,0.001,2334,0.058,0.119,0.006,40001.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-05",24,24,5161,,0.011,0.001,2077.2,0.058,0.107,0.006,35606.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-06",24,24,5356,,0.011,0.001,2134,0.058,0.109,0.006,36577.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-07",24,24,5575,,0.011,0.001,2209.2,0.058,0.111,0.0059,37866.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-08",24,24,5443,,0.011,0.001,2163.7,0.058,0.11,0.006,37086.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-09",24,24,5543,,0.011,0.001,2211.7,0.058,0.111,0.0059,37905.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-10",24,24,5259,,0.011,0.001,2113,0.058,0.108,0.006,36213.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-11",24,24,6083,,0.012,0.001,2397.5,0.058,0.123,0.006,41092.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-12",24,24,5498,,0.011,0.001,2193,0.058,0.113,0.006,37591.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-13",24,24,5261,,0.011,0.001,2112.8,0.058,0.108,0.006,36212.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-14",24,24,5433,,0.011,0.001,2178.5,0.058,0.112,0.006,37338.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-15",24,24,6047,,0.012,0.001,2384.8,0.058,0.122,0.006,40874.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-16",24,24,5677,,0.012,0.001,2263.9,0.058,0.116,0.006,38804,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-17",22,21.13,5183.52,,0.011,0.001,2059.518,0.058,0.105,0.0062,35302.505,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-21",12,10.9,2162.14,,0.005,0.001,903.324,0.058,0.117,0.031,15483.779,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-22",12,11.5,2645,,0.005,0.001,1063.9,0.058,0.08,0.0152,18235.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-23",24,23.97,5857.98,,0.012,0.001,2345.131,0.058,0.118,0.0059,40197.377,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-24",24,24,5842,,0.012,0.001,2313,0.058,0.118,0.006,39644.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-25",24,24,5463,,0.011,0.001,2175.9,0.058,0.111,0.006,37296.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-26",15,13.8,3095.5,,0.006,0.001,1261.569,0.058,0.085,0.0118,21626.352,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-27",24,24,5459,,0.011,0.001,2213.5,0.058,0.112,0.0059,37933.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-28",24,24,5527,,0.011,0.001,2199.1,0.058,0.113,0.006,37689.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-29",24,24,5532,,0.011,0.001,2197.6,0.058,0.112,0.006,37669.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-09-30",24,23.87,5753.76,,0.012,0.001,2280.727,0.058,0.117,0.006,39095.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-01",24,24,5789,,0.012,0.001,2283,0.058,0.116,0.0059,39134.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-02",24,24,5699,,0.012,0.001,2254.4,0.058,0.115,0.006,38643.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-03",24,24,5568,,0.011,0.001,2214,0.058,0.111,0.0058,37948.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-04",24,24,5551,,0.011,0.001,2209.4,0.058,0.112,0.0059,37869.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-05",24,24,5611,,0.012,0.001,2240.1,0.058,0.114,0.006,38393.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-06",24,24,5673,,0.012,0.001,2284.3,0.058,0.115,0.0059,39153,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-07",24,24,5718,,0.012,0.001,2279.5,0.058,0.111,0.0057,39068.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-08",24,24,5722,,0.012,0.001,2277,0.058,0.117,0.006,39029.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-09",24,24,5863,,0.012,0.001,2347.2,0.058,0.119,0.0059,40234.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-10",24,24,5613,,0.011,0.001,2228.9,0.058,0.115,0.006,38201,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-11",24,24,5393,,0.011,0.001,2153.4,0.058,0.11,0.006,36907.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-12",24,24,4993,,0.01,0.001,2015.8,0.058,0.102,0.0059,34549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-13",24,24,5301,,0.011,0.001,2128.6,0.058,0.109,0.006,36486.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-14",24,24,5470,,0.011,0.001,2179.5,0.058,0.11,0.0059,37360.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-15",24,24,5687,,0.012,0.001,2262.9,0.058,0.116,0.006,38783.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-16",24,24,5969,,0.012,0.001,2359.2,0.058,0.12,0.006,40436.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-17",24,24,5789,,0.012,0.001,2303.5,0.058,0.117,0.0059,39481.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-18",24,24,5736,,0.012,0.001,2293,0.058,0.116,0.0059,39306.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-19",24,24,5987,,0.012,0.001,2390.4,0.058,0.123,0.006,40966.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-20",24,24,5975,,0.012,0.001,2376.2,0.058,0.122,0.006,40729,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-21",24,23.35,5760.65,,0.012,0.001,2296.835,0.058,0.119,0.0063,39369.765,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-23",2,1.13,11.94,,0,0.001,33.77,0.058,0.05,0.113,578.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-24",9,8.68,1997.72,,0.004,0.001,815.736,0.058,0.075,0.024,13983.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-25",24,24,5581,,0.012,0.001,2259.9,0.058,0.115,0.006,38736.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-26",18,16.99,3732.73,,0.008,0.001,1534.815,0.058,0.113,0.0107,26309.384,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-27",24,24,5886,,0.012,0.001,2377.7,0.058,0.122,0.006,40751.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-28",24,23.97,5774.44,,0.012,0.001,2306.231,0.058,0.118,0.006,39529.213,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-29",24,24,5460,,0.011,0.001,2202.6,0.058,0.112,0.0059,37756,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-30",24,24,6097,,0.012,0.001,2408.5,0.058,0.124,0.006,41282.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-10-31",24,24,5830,,0.012,0.001,2328.7,0.058,0.12,0.006,39914.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-01",24,24,5814,,0.012,0.001,2313.5,0.058,0.119,0.006,39652.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-02",24,24,5845,,0.012,0.001,2328.2,0.058,0.116,0.0058,39909.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-03",23,22.65,5673.3,,0.012,0.001,2265.53,0.058,0.117,0.0061,38832.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-04",12,11.3,2635.4,,0.005,0.001,1064.1,0.058,0.075,0.0138,18237.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-05",21,20.2,4425.74,,0.009,0.001,1816.439,0.058,0.109,0.0087,31129.783,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-06",24,24,6008,,0.012,0.001,2384,0.058,0.123,0.006,40855.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-07",24,24,5997,,0.012,0.001,2385.3,0.058,0.122,0.006,40882,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-08",24,24,5627,,0.012,0.001,2284.8,0.058,0.116,0.0059,39163.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-09",24,24,6099,,0.013,0.001,2461.1,0.058,0.125,0.0059,42181.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-10",24,24,6075,,0.013,0.001,2440.6,0.058,0.125,0.006,41835.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-11",24,24,6052,,0.012,0.001,2397.2,0.058,0.123,0.006,41085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-12",24,24,6125,,0.012,0.001,2420.9,0.058,0.124,0.006,41497.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-13",24,24,5730,,0.012,0.001,2272.8,0.058,0.116,0.006,38958.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-14",24,23.85,5610,,0.012,0.001,2240.035,0.058,0.114,0.0059,38389.385,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-15",18,17.56,4049.34,,0.009,0.001,1653.476,0.058,0.136,0.0133,28340.034,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-16",24,23.97,6085.29,,0.012,0.001,2399.359,0.058,0.123,0.006,41125.653,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-17",24,24,5750,,0.012,0.001,2299.8,0.058,0.118,0.006,39418.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-18",24,24,5212,,0.011,0.001,2154.5,0.058,0.109,0.0059,36930.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-19",24,24,5765,,0.012,0.001,2314.4,0.058,0.118,0.0059,39668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-20",24,24,6193,,0.012,0.001,2421.3,0.058,0.125,0.006,41501.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-21",19,17.66,4359.32,,0.009,0.001,1720.774,0.0581,0.11,0.0098,29494.644,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-22",16,15.6,3818.56,,0.008,0.001,1522.396,0.058,0.101,0.0096,26091.456,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-23",24,24,6180,,0.012,0.001,2410,0.058,0.124,0.006,41311.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-24",24,24,6053,,0.012,0.001,2373.6,0.058,0.121,0.006,40682.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-25",18,17.15,3902.49,,0.008,0.001,1631.007,0.058,0.115,0.0127,27958.284,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-26",24,24,5447,,0.012,0.001,2239.6,0.058,0.114,0.006,38382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-27",24,24,5462,,0.012,0.001,2245.6,0.058,0.113,0.0059,38490.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-28",1,0.78,89.7,,0,0.001,48.906,0.058,0.004,0.01,837.798,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-29",8,7.05,1525.2,,0.003,0.001,624.11,0.058,0.094,0.0299,10694.415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-11-30",24,23.82,5634.4,,0.012,0.001,2267.406,0.058,0.117,0.006,38861.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-01",12,11.03,2602,,0.005,0.001,1032.934,0.0581,0.083,0.0121,17706.187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-02",24,24,5945,,0.012,0.001,2348.8,0.058,0.12,0.006,40258.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-03",19,18.72,4644.48,,0.009,0.001,1826.36,0.058,0.095,0.0062,31302.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-04",11,10.5,2473,,0.005,0.001,990.5,0.058,0.091,0.0219,16976.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-05",24,24,6020,,0.012,0.001,2374,0.058,0.122,0.006,40687.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-06",21,20.02,4742,,0.01,0.001,1870.744,0.058,0.121,0.0085,32066.562,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-07",24,24,5686,,0.011,0.001,2231.8,0.058,0.115,0.006,38252.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-08",24,24,5950,,0.012,0.001,2338.7,0.058,0.119,0.0059,40085.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-09",12,11.25,2545,,0.005,0.001,1027.9,0.058,0.096,0.0216,17616.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-10",24,23.97,5966.76,,0.012,0.001,2351.444,0.058,0.123,0.0061,40303.903,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-11",10,9.38,2218.32,,0.005,0.001,883.77,0.058,0.08,0.0207,15149.314,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-12",24,24,5741,,0.012,0.001,2274.4,0.058,0.116,0.006,38984.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-13",18,17.37,4191.83,,0.009,0.001,1660.346,0.058,0.119,0.0128,28457.772,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-14",24,24,5694,,0.012,0.001,2269.2,0.058,0.116,0.006,38894.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-15",19,18,4167,,0.009,0.001,1671.66,0.058,0.112,0.0111,28652.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-16",24,24,5912,,0.012,0.001,2356.8,0.058,0.121,0.006,40394,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-17",24,24,5901,,0.012,0.001,2350.6,0.058,0.121,0.006,40289.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-18",14,13.9,3260.29,,0.007,0.001,1303.115,0.058,0.096,0.0121,22337.161,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-19",24,24,5708,,0.012,0.001,2256.9,0.058,0.115,0.006,38683.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-20",24,24,5860,,0.012,0.001,2326.3,0.058,0.119,0.006,39874.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-21",22,21.82,5409.44,,0.011,0.001,2148.484,0.058,0.111,0.0061,36823.382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-22",9,8.15,1820.45,,0.004,0.001,743.53,0.058,0.072,0.015,12743.225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-23",24,23.97,5658.69,,0.012,0.001,2268.702,0.058,0.115,0.0059,38886.519,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-24",12,10.3,2419.25,,0.005,0.001,981.33,0.058,0.086,0.0136,16815.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-25",11,10,2309.87,,0.005,0.001,933.888,0.058,0.083,0.0125,16005.101,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-26",18,16.6,3617.32,,0.008,0.001,1466.252,0.058,0.094,0.0107,25130.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-27",10,8.76,1798.18,,0.004,0.001,746.492,0.058,0.07,0.0178,12796.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-28",12,11.12,2437.24,,0.005,0.001,981.928,0.058,0.082,0.0115,16828.404,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-29",2,1.28,209.12,,0,0.001,94.648,0.058,0.005,0.01,1622.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Haynes Generating Station",400,"9",,"2020-12-31",13,12.42,2352,,0.005,0.001,1004.058,0.058,0.127,0.0282,17208.762,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-01",3,3,0,,0,0.001,17.7,0.058,0,0.002,303.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-08",15,13.65,43,,0.001,0.001,116.118,0.0584,0.155,0.1212,1989.497,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-09",24,24,1126,,0.004,0.001,724.6,0.058,0.005,0.0008,12407.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-10",19,18.8,1238.6,,0.004,0.001,748.62,0.058,0.013,0.0015,12817.06,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-03",1,1,0,,0,0.001,6,0.058,0,0.002,103.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-19",13,11.42,2,,0,0.001,73.404,0.058,0.001,0.0021,1261.003,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-20",24,24,1022,,0.004,0.001,704.7,0.058,0.001,0.0001,12064.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-21",24,24,1038,,0.004,0.001,688.5,0.058,0,0,11790.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-22",24,24,1335,,0.004,0.001,843.3,0.058,0,0,14443.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-23",24,24,1601,,0.005,0.001,987.2,0.058,0.005,0.0008,16901.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-24",24,24,1352,,0.004,0.001,848.3,0.058,0.009,0.001,14526.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-25",24,24,1237,,0.004,0.001,773.3,0.058,0.004,0.0005,13239,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-26",24,24,1358,,0.004,0.001,841.2,0.058,0.002,0.0003,14402.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-27",24,24,1180,,0.004,0.001,749.5,0.058,0.001,0.0001,12829,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-28",24,23.22,1256.42,,0.004,0.001,790.386,0.058,0.002,0.0003,13537.698,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-23",7,5.85,0,,0,0.001,7.02,0.0587,0,0.002,120.591,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-29",14,12.81,95,,0.001,0.0009,153.773,0.0583,0.046,0.0254,2633.166,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-30",10,9.67,467.45,,0.002,0.001,324.48,0.058,0.003,0.0011,5555.408,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-19",17,16.75,67,,0.001,0.001,156.75,0.0584,0.024,0.0168,2681.975,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-20",24,24,1085,,0.004,0.001,721.6,0.058,0.008,0.0013,12356.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-21",19,18.38,1099.54,,0.004,0.001,701.318,0.058,0.009,0.0012,12005.366,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-03",17,14.72,10,,0.001,0.001,101.596,0.0584,0.009,0.0074,1740.05,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-04",12,11.65,432.8,,0.002,0.001,317.44,0.0581,0.002,0.0008,5433.45,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-01",12,11.68,570.28,,0.002,0.001,372.632,0.058,0.022,0.0093,6378.864,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-02",24,24,1176,,0.004,0.001,758,0.058,0.036,0.0056,12976.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-03",24,24,1286,,0.004,0.001,822.3,0.058,0.002,0.0002,14083,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-04",24,24,1306,,0.004,0.001,829.9,0.058,0.002,0.0002,14212.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-05",24,24,1175,,0.004,0.001,758.2,0.058,0.002,0.0004,12979.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-06",24,24,1334,,0.004,0.001,846,0.058,0.009,0.0011,14489.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-07",24,24,1327,,0.004,0.001,850.4,0.058,0.007,0.0007,14559.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-08",24,24,1147,,0.004,0.001,755,0.058,0,0,12929.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-09",20,19.35,916.85,,0.003,0.001,601.825,0.058,0.002,0.0003,10307.465,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-12",23,19.21,338,,0.002,0.001,308.927,0.0583,0.006,0.0049,5287.365,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-13",24,24,1230,,0.004,0.001,800.1,0.058,0,0,13701.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-14",24,24,1167,,0.004,0.001,757.3,0.058,0,0,12969.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-15",24,24,1207,,0.004,0.001,770.9,0.058,0.003,0.0005,13202.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-16",24,24,1182,,0.004,0.001,760.1,0.058,0.002,0.0003,13014.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-17",24,24,1181,,0.004,0.001,760.4,0.058,0.001,0.0001,13020.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-18",24,24,1172,,0.004,0.001,756.8,0.058,0,0,12959.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-19",24,24,1180,,0.004,0.001,754.2,0.058,0,0,12910.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-20",24,24,1183,,0.004,0.001,754,0.058,0,0,12914.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-21",24,24,1190,,0.004,0.001,755.2,0.058,0,0,12928.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-22",24,24,1177,,0.004,0.001,748.3,0.058,0.003,0.0004,12807.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-23",24,24,1176,,0.004,0.001,748.8,0.058,0.002,0.0003,12825,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-24",24,24,1159,,0.004,0.001,745.3,0.058,0.005,0.0008,12764.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-25",24,24,1214,,0.004,0.001,775.1,0.058,0.008,0.0011,13267.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-26",24,24,1177,,0.004,0.001,743.1,0.058,0,0,12723.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-27",9,8.52,403.96,,0.001,0.001,259.088,0.058,0,0,4437.976,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-15",12,9.75,0,,0,0.001,64.137,0.0588,0.002,0.0037,1095.778,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-16",24,23.73,1010.46,,0.004,0.001,688.37,0.058,0.005,0.0008,11788.866,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-17",24,24,1209,,0.004,0.001,765.5,0.058,0.006,0.0009,13109.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-18",24,24,1195,,0.004,0.001,758.2,0.058,0.011,0.0017,12985.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-19",24,24,1554,,0.005,0.001,966.1,0.058,0.103,0.0113,16541.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-20",18,17.17,842.85,,0.003,0.001,537.274,0.058,0.007,0.0014,9200.062,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-29",11,10.38,0,,0,0.001,61.552,0.0585,0.001,0.003,1053.526,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-30",24,24,809,,0.003,0.001,602.3,0.0582,0.002,0.0005,10313.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"1",,"2020-12-31",24,24,1210,,0.004,0.001,770.2,0.058,0.007,0.0011,13188.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-01",3,3,0,,0,0.001,17.1,0.059,0,0.002,291.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-17",16,15.48,1,,0,0.001,86.974,0.0583,0.003,0.0048,1490.34,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-18",21,20.37,2218.07,,0.007,0.001,1379.08,0.058,0.174,0.0112,23613.537,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-03",1,1,0,,0,0.001,5.8,0.058,0,0.002,99.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-10",17,16.77,291,,0.001,0.001,276.295,0.0582,0.004,0.0016,4730.308,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-11",24,23.52,1051.44,,0.004,0.001,693.152,0.058,0.009,0.0015,11862.62,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-12",16,15.73,1536.01,,0.005,0.001,908.853,0.058,0.1,0.0086,15561.402,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-13",17,16.63,77,,0.001,0.001,171.568,0.0583,0.006,0.0059,2940.43,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-14",24,24,1129,,0.004,0.001,732.4,0.058,0,0,12537.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-15",18,18,884,,0.003,0.001,554.9,0.058,0.013,0.0027,9496.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-20",13,11.92,33,,0.001,0.001,108.576,0.0583,0.007,0.0075,1859.222,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-21",24,24,1061,,0.004,0.001,706.2,0.058,0,0,12088.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-22",24,24,1278,,0.004,0.001,808.7,0.058,0.013,0.0014,13843.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-23",24,24,1114,,0.004,0.001,713.6,0.058,0,0,12220.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-24",24,24,1166,,0.004,0.001,738,0.058,0.027,0.0045,12635.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-25",24,24,1139,,0.004,0.001,723.3,0.058,0.002,0.0002,12387.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-26",24,24,1257,,0.004,0.001,782.9,0.058,0.003,0.0004,13406.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-27",24,24,1112,,0.004,0.001,702,0.058,0,0,12020.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-28",24,24,1261,,0.004,0.001,784.5,0.058,0.003,0.0004,13434.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-29",24,24,1031,,0.004,0.001,681.6,0.058,0,0.0001,11668.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-06-30",18,17.18,732.9,,0.002,0.001,486.116,0.058,0,0,8324.422,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-07",1,0.02,0,,0,0.001,0.074,0.058,0,0,1.284,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-08",13,11.7,0,,0,0.001,59.964,0.0582,0.001,0.002,1025.878,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-09",24,22.52,568,,0.002,0.001,471.565,0.0583,0.061,0.0163,8075.551,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-10",24,24,1963,,0.006,0.001,1200,0.058,0.028,0.0032,20544.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-11",24,23.98,1729.5,,0.006,0.001,1081.84,0.058,0.016,0.0011,18522.196,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-12",24,24,1608,,0.005,0.001,1005.7,0.058,0.008,0.0006,17222.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-13",24,24,1168,,0.004,0.001,745,0.058,0.016,0.0025,12758,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-14",8,7.27,351.97,,0.001,0.001,226.448,0.058,0.003,0.0015,3877.237,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-29",12,11.1,18,,0.001,0.001,105.71,0.0585,0.015,0.0173,1808.67,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-30",24,24,1083,,0.004,0.001,715.3,0.058,0.043,0.0069,12246,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-07-31",24,24,1092,,0.004,0.001,686.8,0.058,0,0,11759,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-01",24,24,1086,,0.004,0.001,682.5,0.058,0,0,11685.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-02",24,24,1081,,0.004,0.001,682.6,0.058,0,0,11689.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-03",12,11.97,518.98,,0.002,0.001,330.761,0.058,0,0,5661.85,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-14",15,14.9,81,,0.001,0.001,156.65,0.0583,0.011,0.0108,2682.14,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-15",24,24,1051,,0.004,0.001,684.4,0.058,0.013,0.0024,11723.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-16",24,24,1073,,0.003,0.001,678.3,0.058,0.006,0.0011,11612.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-17",24,24,1517,,0.005,0.001,911,0.058,0.011,0.001,15598.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-18",24,24,1603,,0.005,0.001,954.1,0.058,0.012,0.001,16338,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-19",24,24,1520,,0.005,0.001,913.9,0.058,0.005,0.0004,15650.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-20",24,24,1100,,0.004,0.001,694.6,0.058,0,0,11893.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-21",24,24,1919,,0.006,0.001,1139.2,0.058,0.021,0.0015,19506.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-22",24,24,1065,,0.004,0.001,680.9,0.058,0,0,11664.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-23",24,23.73,1763.06,,0.005,0.001,1055.52,0.058,0.019,0.0014,18070.946,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-24",24,23.85,1193.01,,0.004,0.001,757.982,0.058,0.005,0.0008,12976.346,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-25",24,23.88,1544,,0.005,0.001,934.58,0.058,0.008,0.0009,15998.292,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-26",24,24,1515,,0.005,0.001,915.7,0.058,0.006,0.0005,15675,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-27",24,24,1315,,0.004,0.001,806.9,0.058,0.009,0.0011,13815.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-28",24,24,1099,,0.004,0.001,687.3,0.058,0,0,11767.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-29",24,24,1103,,0.004,0.001,690.4,0.058,0.001,0.0001,11821.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-30",21,20.13,917.52,,0.003,0.001,573.849,0.058,0,0,9826.589,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-02",11,9.85,35,,0,0.001,96.957,0.0585,0.014,0.018,1658.093,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-03",24,24,1094,,0.004,0.001,708,0.058,0,0,12128.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-04",24,24,1180,,0.004,0.001,730.7,0.058,0.002,0.0003,12515.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-05",24,24,1711,,0.005,0.001,1012.7,0.058,0.017,0.0015,17345.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-06",24,24,1829,,0.006,0.001,1078,0.058,0.018,0.0012,18459.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-07",24,24,1143,,0.004,0.001,714.7,0.0581,0.006,0.0008,12238.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-08",24,23.3,1026.2,,0.003,0.001,672.456,0.058,0.006,0.001,11510.27,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-09",24,24,1165,,0.004,0.001,729.6,0.058,0.007,0.001,12495.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-10",24,24,1062,,0.003,0.001,670.3,0.058,0.013,0.0023,11476.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-11",24,24,1597,,0.005,0.001,951,0.058,0.018,0.002,16282.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-12",24,24,1096,,0.004,0.001,694.6,0.058,0.006,0.001,11895,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-13",24,24,1071,,0.003,0.001,676.6,0.058,0.001,0.0002,11584,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-14",24,24,1581,,0.005,0.001,947,0.058,0.017,0.0014,16214.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-15",24,24,1051,,0.003,0.001,681,0.058,0.004,0.0007,11659.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-16",24,24,1441,,0.005,0.001,877,0.058,0.022,0.0022,15012.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-17",24,24,1653,,0.005,0.001,994.4,0.058,0.024,0.002,17024.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-18",24,24,1964,,0.006,0.001,1159.5,0.058,0.037,0.0029,19850.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-19",24,24,1750,,0.005,0.001,1054.4,0.058,0.027,0.0022,18059,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-20",24,24,1772,,0.005,0.001,1062.1,0.058,0.027,0.0021,18189.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-21",24,24,1525,,0.005,0.001,922.3,0.058,0.011,0.0008,15794.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-22",24,24,1626,,0.005,0.001,979.4,0.058,0.006,0.0005,16773.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-23",24,24,1058,,0.003,0.001,676.1,0.058,0,0,11577.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-24",24,24,1189,,0.004,0.001,740.5,0.058,0.005,0.0006,12678.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-25",24,24,1442,,0.004,0.001,875.5,0.058,0.012,0.0013,14988.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-26",24,24,1061,,0.004,0.001,682.5,0.058,0.004,0.0008,11688.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-27",24,24,1059,,0.003,0.001,678.3,0.058,0.009,0.0015,11613.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-28",24,24,1462,,0.005,0.001,889.2,0.058,0.018,0.0021,15225.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-29",24,24,1380,,0.004,0.001,851.6,0.058,0.006,0.0007,14582.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-09-30",17,16.3,846.2,,0.003,0.001,542.3,0.058,0.004,0.0005,9284.82,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-21",13,12.82,168,,0.001,0.001,195.854,0.0585,0.028,0.0205,3353.436,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-22",24,24,1058,,0.004,0.001,682.1,0.058,0.004,0.0008,11683,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-23",24,24,1174,,0.004,0.001,753.2,0.058,0.008,0.0008,12897.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-24",24,24,1293,,0.004,0.001,817.5,0.058,0.003,0.0004,13994.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-25",24,24,1257,,0.004,0.001,802.5,0.058,0.003,0.0002,13739.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-26",24,24,1040,,0.003,0.001,678.7,0.058,0.008,0.0014,11626.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-27",24,24,1047,,0.003,0.001,677.8,0.058,0.003,0.0005,11606.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-28",24,24,1051,,0.004,0.001,684,0.058,0.003,0.0006,11715.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-29",24,24,1054,,0.004,0.001,685.1,0.058,0,0,11728.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-30",24,24,1037,,0.003,0.001,673.9,0.058,0,0,11539.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-10-31",24,24,1058,,0.003,0.001,678.5,0.058,0,0,11620.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-01",24,24,1046,,0.003,0.001,674.4,0.058,0,0,11550.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-02",24,24,1041,,0.003,0.001,669.6,0.058,0,0,11467.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-03",24,24,1104,,0.004,0.001,697.7,0.058,0.001,0.0002,11945.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-04",24,24,1079,,0.004,0.001,687.5,0.058,0,0,11774,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-05",24,24,1075,,0.004,0.001,684.7,0.058,0,0,11723.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-06",24,24,1044,,0.003,0.001,672.2,0.058,0.001,0.0001,11512.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-07",24,24,1062,,0.004,0.001,687.1,0.058,0.141,0.0239,11762.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-08",24,24,1076,,0.004,0.001,687.1,0.058,0.043,0.0073,11764.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-09",24,24,1080,,0.004,0.001,683.5,0.058,0,0,11704.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-10",24,24,1072,,0.004,0.001,682.1,0.058,0.005,0.0008,11679.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-11",24,24,1080,,0.004,0.001,684,0.058,0.007,0.0011,11709.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-12",24,24,1080,,0.004,0.001,682.8,0.058,0.003,0.0005,11691.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-13",24,24,1079,,0.003,0.001,681.2,0.058,0.001,0.0003,11662,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-14",24,24,1077,,0.004,0.001,681.9,0.058,0,0,11679.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-15",24,24,1080,,0.003,0.001,680.3,0.058,0.006,0.001,11649.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-16",24,24,1222,,0.004,0.001,749.9,0.058,0.063,0.0091,12843.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-17",24,24,1061,,0.003,0.001,675.4,0.058,0.002,0.0004,11564.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-18",24,24,1068,,0.003,0.001,674.3,0.058,0.002,0.0003,11551.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-19",24,24,1064,,0.003,0.001,674.7,0.058,0.005,0.0008,11553,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-20",24,24,1622,,0.005,0.001,966.8,0.058,0.142,0.0143,16553.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-21",24,24,1056,,0.003,0.001,669,0.058,0.002,0.0003,11450.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-22",24,24,1044,,0.003,0.001,666,0.058,0.005,0.0008,11403.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-23",24,24,1049,,0.003,0.001,673.6,0.058,0.006,0.001,11534.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-24",24,24,1056,,0.003,0.001,669.5,0.058,0.006,0.0011,11465.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-25",24,24,1056,,0.003,0.001,672.5,0.058,0.007,0.0012,11512.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-26",24,24,1058,,0.003,0.001,674.9,0.058,0.011,0.0019,11558.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-27",24,24,1056,,0.003,0.001,672.2,0.058,0.008,0.0014,11508.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-28",24,24,1060,,0.003,0.001,675.2,0.058,0.009,0.0015,11564.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-29",24,24,1065,,0.003,0.001,679.9,0.058,0.007,0.0011,11638.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-11-30",24,24,1058,,0.003,0.001,671.4,0.058,0.005,0.0009,11495.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-01",24,24,1048,,0.003,0.001,668.8,0.058,0.007,0.0012,11453.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-02",24,24,1054,,0.003,0.001,670.6,0.058,0.006,0.001,11483.3,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-03",24,24,1060,,0.003,0.001,674,0.058,0.007,0.0013,11540.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-04",24,24,1055,,0.003,0.001,671.6,0.058,0.004,0.0007,11499.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-05",24,24,1048,,0.003,0.001,667.4,0.058,0.004,0.0008,11434.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-06",24,24,1054,,0.003,0.001,665.9,0.058,0.002,0.0004,11399.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-07",24,24,1049,,0.003,0.001,669.5,0.058,0.002,0.0004,11466.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-08",24,24,1062,,0.003,0.001,676.1,0.058,0.001,0.0003,11575.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-09",24,24,1057,,0.003,0.001,671.5,0.058,0.003,0.0005,11497.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-10",24,24,1050,,0.003,0.001,667.3,0.0581,0.002,0.0003,11428.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-11",24,24,1040,,0.003,0.001,665.1,0.058,0.001,0.0002,11390.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-12",24,24,1046,,0.003,0.001,665.6,0.058,0.002,0.0003,11397.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-13",24,24,1044,,0.003,0.001,662.9,0.058,0.002,0.0004,11354.8,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-14",24,24,1048,,0.003,0.001,666.4,0.058,0.005,0.0009,11408.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-15",24,24,1053,,0.003,0.001,667.8,0.058,0.007,0.0012,11434.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-16",24,23.85,1039.45,,0.003,0.001,671.8,0.058,0.004,0.0008,11503.965,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-17",22,21.65,859,,0.003,0.001,585.575,0.058,0.003,0.0006,10028.455,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-18",24,24,1060,,0.004,0.001,684.1,0.058,0.004,0.0007,11713.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-19",24,24,1061,,0.003,0.001,678.7,0.058,0.005,0.0008,11622.5,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-20",24,24,1064,,0.003,0.001,678.8,0.058,0.006,0.0011,11623.1,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-21",24,24,1067,,0.003,0.001,680.6,0.058,0.003,0.0005,11649.9,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-22",24,24,1056,,0.003,0.001,677.8,0.0581,0.003,0.0005,11601.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-23",24,24,1061,,0.003,0.001,677,0.058,0.008,0.0013,11593.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-24",24,24,1080,,0.004,0.001,683.9,0.058,0.012,0.0021,11707.7,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-25",24,24,1063,,0.004,0.001,682,0.058,0.006,0.001,11683.4,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-26",24,24,1068,,0.004,0.001,690,0.058,0.004,0.0008,11812.6,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-27",24,24,1080,,0.004,0.001,692.5,0.058,0.006,0.001,11863.2,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-28",23,21.62,807,,0.003,0.001,572.59,0.058,0.032,0.0072,9803.738,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-29",12,11.97,517.8,,0.002,0.001,356.6,0.058,0.007,0.0022,6105.213,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Other Gas","Dry bottom wall-fired boiler",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-13",3,0.12,0,,0,0.001,0.601,0.058,0,0.026,10.298,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-14",4,1.34,0,,0,0.001,35.114,0.0583,0.012,0.039,601.325,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-15",2,1.7,97.82,,0.001,0.001,103.703,0.058,0.004,0.005,1775.674,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-18",6,3.05,125.27,,0.001,0.0008,161.023,0.0582,0.021,0.0277,2756.283,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-19",11,10.47,1014.47,,0.004,0.001,697.661,0.058,0.047,0.0112,11945.859,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-20",24,24,5769,,0.013,0.001,2439.5,0.058,0.106,0.0051,41770.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-21",24,24,5863,,0.013,0.001,2470.3,0.058,0.111,0.0053,42304.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-22",24,24,6338,,0.013,0.001,2620.3,0.058,0.124,0.0055,44866.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-23",24,24,5546,,0.012,0.001,2365.3,0.058,0.107,0.0053,40499.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-24",24,24,6369,,0.014,0.001,2638.1,0.058,0.117,0.0052,45174.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-25",24,24,6352,,0.014,0.001,2638,0.058,0.123,0.0054,45163,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-26",24,24,6539,,0.014,0.001,2704.7,0.058,0.13,0.0056,46316.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-27",24,24,6831,,0.014,0.001,2814.5,0.058,0.134,0.0056,48190.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-28",24,23.98,7228.9,,0.015,0.001,2964.562,0.058,0.131,0.0052,50764.452,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-02-29",12,10.05,2151.78,,0.005,0.001,979.12,0.058,0.046,0.0108,16763.373,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-01",16,14.78,1975.62,,0.005,0.001,1062.289,0.0581,0.046,0.0051,18192.637,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-02",18,17.31,3587.63,,0.008,0.001,1611.747,0.058,0.065,0.0046,27598.912,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-03",24,24,6673,,0.014,0.001,2751.8,0.058,0.128,0.0055,47121.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-04",24,23,6596,,0.014,0.001,2817.23,0.058,0.133,0.0055,48241.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-05",24,24,7189,,0.015,0.001,2911.6,0.058,0.128,0.0051,49860.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-06",24,24,7446,,0.015,0.001,3003.1,0.058,0.131,0.0051,51419,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-07",2,1.4,214.8,,0.001,0.001,111.22,0.058,0.006,0.0065,1904.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-08",9,9,2306,,0.005,0.001,997.9,0.058,0.068,0.0103,17087.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-09",24,24,6489,,0.014,0.001,2679.8,0.058,0.128,0.0055,45887.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-10",24,24,7290,,0.015,0.001,2964.7,0.058,0.143,0.0056,50762.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-11",10,9.63,2278.62,,0.005,0.001,975.405,0.058,0.049,0.0059,16702.347,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-12",13,12.82,3007.44,,0.007,0.001,1309.888,0.058,0.072,0.0081,22430.452,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-13",11,8.6,1849.48,,0.005,0.001,961.935,0.058,0.048,0.0091,16471.541,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-16",12,11.03,2663,,0.006,0.0009,1159.641,0.0581,0.057,0.0088,19856.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-17",24,24,5614,,0.012,0.001,2373.6,0.058,0.108,0.0053,40646.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-18",24,24,5911,,0.013,0.001,2467.9,0.058,0.12,0.0056,42257.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-19",24,24,6584,,0.014,0.001,2684.6,0.058,0.135,0.0058,45970.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-20",17,16.95,3944.25,,0.009,0.001,1675.6,0.058,0.08,0.0056,28691.965,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-21",10,9.3,2330.7,,0.005,0.001,999.95,0.058,0.041,0.0089,17121.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-22",24,24,5054,,0.011,0.001,2199,0.058,0.098,0.0052,37656.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-23",1,0.02,0,,0,0.001,0.274,0.058,0,0.001,4.696,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-24",11,10.52,2579.48,,0.006,0.001,1135.344,0.058,0.056,0.0089,19440.72,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-25",24,24,6835,,0.014,0.001,2782.2,0.058,0.122,0.0051,47642.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-26",18,16.2,3671.68,,0.008,0.001,1629.768,0.058,0.072,0.0049,27906.696,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-27",2,1.65,192.7,,0.001,0.001,111.965,0.058,0.005,0.0055,1917.105,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-03",11,10.08,2184,,0.005,0.001,1012.008,0.0581,0.071,0.01,17327.468,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-04",24,24,5987,,0.013,0.001,2506.8,0.058,0.109,0.0051,42921.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-05",24,24,6816,,0.014,0.001,2781.3,0.058,0.122,0.0052,47624.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-06",24,24,6427,,0.014,0.001,2645.5,0.058,0.123,0.0054,45299.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-07",24,24,7043,,0.015,0.001,2849,0.058,0.13,0.0053,48787.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-08",24,24,7029,,0.015,0.001,2841,0.058,0.132,0.0055,48647,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-09",24,24,7141,,0.015,0.001,2884.6,0.058,0.127,0.0052,49394.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-10",24,24,6441,,0.014,0.001,2640.4,0.058,0.117,0.0052,45212.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-11",16,15.37,3810.86,,0.008,0.001,1627.65,0.058,0.076,0.0058,27871.045,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-12",19,18.6,5275.72,,0.011,0.001,2184.773,0.058,0.088,0.0045,37409.128,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-13",24,24,6923,,0.014,0.001,2806.7,0.058,0.127,0.0053,48061.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-14",19,17.47,4064.9,,0.009,0.001,1758.645,0.058,0.09,0.0057,30114.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-15",17,14.79,3200.62,,0.007,0.001,1417.481,0.058,0.071,0.0058,24273.28,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-16",10,9.03,2332,,0.005,0.001,996.277,0.0581,0.061,0.0073,17062.109,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-17",24,24,5771,,0.012,0.001,2422.4,0.058,0.124,0.006,41482.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-18",9,8.98,2568.7,,0.005,0.001,1048.312,0.058,0.055,0.0061,17950.414,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-21",10,9.05,1952.05,,0.005,0.001,885.57,0.0581,0.071,0.0107,15165.115,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-22",16,15.48,3708.85,,0.008,0.001,1610.648,0.058,0.082,0.0061,27577.329,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-23",19,16.4,4065.76,,0.009,0.001,1750.09,0.0581,0.076,0.0048,29969.12,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-24",14,12.47,3220.16,,0.007,0.001,1374.815,0.0581,0.081,0.007,23540.962,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-25",13,12.38,3371.08,,0.007,0.001,1413.428,0.058,0.076,0.0085,24204.342,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-26",20,19.4,4198.36,,0.009,0.001,1831.565,0.058,0.087,0.0054,31364.009,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-27",14,11.97,2869.59,,0.007,0.001,1281.583,0.058,0.055,0.005,21946.554,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-28",21,20.2,5113.65,,0.011,0.001,2148.227,0.058,0.1,0.0054,36785.582,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-29",17,15.25,3405.52,,0.008,0.0009,1478.029,0.0581,0.073,0.0056,25307.077,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-04-30",18,17.08,3708.96,,0.008,0.001,1636.346,0.058,0.079,0.0058,28017.328,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-04",13,12.37,3215.48,,0.007,0.001,1384.345,0.058,0.088,0.0158,23705.475,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-05",24,24,6731,,0.014,0.001,2753.6,0.058,0.143,0.0061,47149.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-06",24,23.67,5080.27,,0.011,0.001,2197.781,0.058,0.115,0.0062,37631.604,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-07",14,13.48,3661.56,,0.008,0.001,1542.36,0.058,0.079,0.0064,26413.956,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-08",16,14.58,3948.48,,0.009,0.001,1656.156,0.058,0.08,0.0064,28359.728,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-09",12,9.56,1753.3,,0.004,0.001,836.635,0.058,0.047,0.0118,14326.856,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-19",21,20.92,4754.6,,0.011,0.001,2082.676,0.058,0.111,0.0064,35660.172,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-20",6,5.88,1530.4,,0.003,0.001,638.9,0.058,0.034,0.0063,10939.948,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-23",12,11.04,2677.98,,0.006,0.001,1155.174,0.058,0.07,0.0124,19782.064,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-24",15,13.28,2874.7,,0.007,0.001,1276.738,0.058,0.067,0.0073,21861.428,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-25",11,10.53,2893.31,,0.006,0.001,1207.524,0.058,0.067,0.0085,20676.047,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-26",24,24,6106,,0.013,0.001,2525.2,0.058,0.13,0.006,43234.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-27",24,24,5961,,0.013,0.001,2477.2,0.058,0.114,0.0053,42417.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-28",24,24,5974,,0.013,0.001,2484.8,0.058,0.12,0.0057,42544.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-29",24,24,7263,,0.015,0.001,2919.5,0.058,0.151,0.006,49991.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-30",17,15.73,4275.67,,0.009,0.001,1780.295,0.058,0.09,0.0064,30484.518,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-05-31",16,14.85,3428.4,,0.008,0.001,1486.759,0.058,0.074,0.0063,25458.615,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-01",24,24,5870,,0.013,0.001,2455.9,0.058,0.122,0.0058,42055.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-02",24,24,6898,,0.014,0.001,2798.1,0.058,0.144,0.006,47910.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-03",24,24,7205,,0.015,0.001,2904.3,0.058,0.143,0.0057,49730,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-04",24,24,6703,,0.014,0.001,2731,0.058,0.139,0.0059,46761.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-05",16,15.73,4191.51,,0.009,0.001,1730.458,0.058,0.09,0.0062,29629.991,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-06",9,8.23,2229.92,,0.005,0.001,937.316,0.058,0.051,0.0116,16046.985,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-07",16,13.47,3048.56,,0.007,0.001,1323.303,0.0581,0.071,0.008,22658.983,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-09",14,13.57,3703.83,,0.008,0.001,1548.24,0.058,0.105,0.0151,26513.33,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-10",24,24,6540,,0.014,0.001,2675.6,0.058,0.14,0.0062,45818,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-11",24,24,5752,,0.012,0.001,2405.8,0.058,0.124,0.006,41197.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-12",24,24,5904,,0.013,0.001,2455.4,0.058,0.129,0.0062,42046.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-13",6,5.12,665.27,,0.002,0.001,345.642,0.058,0.027,0.0143,5917.927,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-15",6,4.47,347.51,,0.001,0.001,291.442,0.0582,0.015,0.011,4988.646,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-01",1,0.02,0,,0,0.001,0.06,0.058,0,0,1.026,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-02",17,16.61,3743.11,,0.009,0.001,1667.834,0.058,0.085,0.0064,28559.736,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-03",14,13.98,3789.72,,0.008,0.001,1567.81,0.058,0.083,0.0062,26849.61,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-04",24,24,5853,,0.012,0.001,2426.2,0.058,0.123,0.0059,41544.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-05",24,24,6433,,0.013,0.001,2610.5,0.058,0.137,0.0061,44703.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-06",24,24,7418,,0.015,0.001,2945.3,0.058,0.144,0.0057,50435.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-07",20,19.4,4981.24,,0.011,0.001,2063.512,0.058,0.087,0.0047,35329.284,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-08",24,24,6388,,0.013,0.001,2597.2,0.058,0.131,0.0058,44468.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-09",24,24,6556,,0.014,0.001,2649.8,0.058,0.135,0.0059,45372.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-10",24,24,6198,,0.013,0.001,2537.1,0.058,0.129,0.0059,43442.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-11",24,23.98,6139.82,,0.013,0.001,2521.102,0.058,0.127,0.0058,43161.138,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-12",24,24,6149,,0.013,0.001,2521.2,0.058,0.131,0.0061,43169.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-13",24,23.95,5595.85,,0.012,0.001,2337.6,0.058,0.119,0.006,40024.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-07-31",12,11.55,1624.95,,0.004,0.001,851.245,0.058,0.064,0.0155,14577.255,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-01",24,24,5747,,0.012,0.001,2378.1,0.058,0.123,0.006,40719,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-02",24,24,5868,,0.012,0.001,2409.4,0.058,0.123,0.006,41261.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-03",24,24,6345,,0.013,0.001,2558.5,0.058,0.134,0.0061,43810.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-04",24,24,6183,,0.013,0.001,2513.3,0.058,0.133,0.0062,43037.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-05",24,24,6329,,0.013,0.001,2566.7,0.058,0.136,0.0062,43950.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-06",20,17.6,3397.71,,0.008,0.001,1503.901,0.058,0.064,0.0045,25753.945,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-07",12,11.93,3312.31,,0.007,0.001,1340.273,0.058,0.072,0.0063,22950.93,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-08",24,24,5555,,0.012,0.001,2304.3,0.058,0.118,0.006,39456.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-09",24,24,6707,,0.014,0.001,2682.9,0.058,0.139,0.006,45938.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-10",24,24,5406,,0.012,0.001,2256.7,0.058,0.113,0.0058,38643.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-11",24,24,5597,,0.012,0.001,2313.4,0.058,0.118,0.0059,39614.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-12",24,24,5943,,0.012,0.001,2430.5,0.058,0.125,0.006,41619.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-13",24,24,6485,,0.013,0.001,2617.1,0.058,0.133,0.0059,44811,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-14",24,24,6942,,0.014,0.001,2763.8,0.058,0.143,0.006,47332.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-15",24,24,5929,,0.012,0.001,2430,0.058,0.124,0.0059,41607.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-16",24,24,5230,,0.011,0.001,2206.9,0.058,0.112,0.0059,37787.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-17",24,24,5735,,0.012,0.001,2375.8,0.058,0.122,0.006,40680.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-18",24,24,5434,,0.012,0.001,2271.5,0.058,0.115,0.0059,38892,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-19",24,24,5566,,0.012,0.001,2314.6,0.058,0.118,0.006,39634.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-20",24,24,4752,,0.01,0.001,2040.8,0.058,0.105,0.006,34948.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-21",24,24,5737,,0.012,0.001,2373.8,0.058,0.123,0.006,40644,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-22",24,24,6389,,0.013,0.001,2590.4,0.058,0.133,0.006,44358.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-23",24,24,6466,,0.013,0.001,2606.5,0.058,0.133,0.006,44630.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-24",24,24,7331,,0.015,0.001,2902.1,0.058,0.15,0.006,49692,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-25",24,23.9,6224.6,,0.013,0.001,2533.09,0.058,0.132,0.0061,43371.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-26",24,24,5860,,0.012,0.001,2400.4,0.058,0.125,0.0061,41105.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-27",24,24,5550,,0.012,0.001,2308.9,0.058,0.117,0.0059,39536.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-28",24,24,5815,,0.012,0.001,2383,0.058,0.121,0.0059,40806.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-29",24,24,4885,,0.011,0.001,2078.4,0.058,0.103,0.0058,35591.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-30",24,24,4727,,0.01,0.001,2027.8,0.058,0.105,0.0061,34723.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-08-31",24,24,6922,,0.014,0.001,2748.4,0.058,0.142,0.006,47062.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-01",24,24,5604,,0.012,0.001,2315.6,0.058,0.123,0.0062,39649.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-02",24,24,6562,,0.014,0.001,2639.5,0.058,0.137,0.006,45197.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-03",24,24,5724,,0.012,0.001,2361.2,0.058,0.121,0.006,40430.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-04",24,24,7089,,0.014,0.001,2817.2,0.058,0.146,0.006,48241,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-05",24,24,5548,,0.012,0.001,2311.3,0.058,0.12,0.0061,39576.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-06",24,24,5517,,0.012,0.001,2304.6,0.058,0.12,0.0061,39463.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-07",24,24,5871,,0.012,0.001,2413.9,0.058,0.123,0.006,41332.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-08",24,23.37,5477.41,,0.012,0.001,2314.508,0.058,0.119,0.006,39633.15,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-09",24,24,5867,,0.012,0.001,2407,0.058,0.123,0.006,41213.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-10",24,24,5265,,0.011,0.001,2206.4,0.058,0.107,0.0056,37781.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-11",24,24,6817,,0.014,0.001,2710.5,0.058,0.144,0.0062,46411.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-12",24,23.87,5308.31,,0.011,0.001,2221.059,0.058,0.113,0.006,38034.615,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-13",10,9.88,2452.28,,0.005,0.001,1036.424,0.058,0.051,0.0067,17746.732,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-14",24,24,5692,,0.012,0.001,2353.8,0.058,0.122,0.006,40306.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-15",14,12.88,2947.54,,0.007,0.001,1270.512,0.058,0.061,0.0061,21755.816,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-16",24,24,5939,,0.013,0.001,2438.6,0.058,0.128,0.0061,41756.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-17",24,24,6210,,0.013,0.001,2522.4,0.058,0.13,0.006,43191.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-18",24,24,6733,,0.014,0.001,2704.2,0.058,0.141,0.0061,46304.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-19",24,24,6423,,0.013,0.001,2594,0.058,0.136,0.0061,44420.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-20",24,24,6582,,0.014,0.001,2645.6,0.058,0.133,0.0058,45296.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-21",24,24,6031,,0.013,0.001,2463.9,0.058,0.126,0.006,42190.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-22",24,24,6190,,0.013,0.001,2524.2,0.058,0.134,0.0062,43220.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-23",24,24,6975,,0.014,0.001,2804.4,0.058,0.145,0.006,48021.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-24",24,24,6398,,0.013,0.001,2586.1,0.058,0.137,0.0062,44282.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-25",24,24,5839,,0.012,0.001,2411.1,0.058,0.122,0.0059,41288.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-26",24,24,6595,,0.014,0.001,2666.5,0.058,0.139,0.0061,45661.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-27",24,24,5601,,0.012,0.001,2331.7,0.058,0.12,0.006,39920.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-28",24,24,5781,,0.012,0.001,2397.9,0.058,0.124,0.006,41055.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-29",24,24,5907,,0.013,0.001,2447.3,0.058,0.127,0.006,41903.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-09-30",24,24,6740,,0.014,0.001,2732.8,0.058,0.142,0.0061,46793.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-01",24,24,6403,,0.013,0.001,2617.9,0.058,0.136,0.0061,44829.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-02",24,24,6326,,0.013,0.001,2583.5,0.058,0.133,0.006,44238.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-03",24,24,5956,,0.013,0.001,2452.7,0.058,0.126,0.006,41996.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-04",24,24,5794,,0.012,0.001,2410.3,0.058,0.125,0.006,41269.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-05",24,24,6068,,0.013,0.001,2501.9,0.058,0.129,0.006,42843.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-06",24,24,6320,,0.013,0.001,2586.7,0.058,0.136,0.0062,44293.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-07",24,24,6440,,0.013,0.001,2621.2,0.058,0.136,0.0061,44882.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-08",24,24,6105,,0.013,0.001,2508.9,0.058,0.128,0.006,42959.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-09",22,21.53,5474,,0.012,0.001,2261.109,0.058,0.12,0.0063,38717.247,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-11",2,0.3,0.56,,0,0.001,7.802,0.0585,0.004,0.034,133.414,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-12",24,24,4966,,0.011,0.001,2152.4,0.058,0.111,0.006,36853.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-13",24,24,4935,,0.011,0.001,2111.2,0.058,0.109,0.006,36148.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-14",24,24,5882,,0.012,0.001,2422.2,0.058,0.126,0.0061,41475.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-15",24,24,6129,,0.013,0.001,2506.3,0.058,0.13,0.006,42910.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-16",24,24,7171,,0.015,0.001,2849,0.058,0.146,0.006,48788.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-17",24,24,6489,,0.013,0.001,2612.8,0.058,0.138,0.0062,44736.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-18",24,24,6356,,0.013,0.001,2587.2,0.058,0.133,0.006,44297.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-19",24,24,6697,,0.014,0.001,2687,0.058,0.14,0.0061,46013.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-20",24,24,6145,,0.013,0.001,2509.1,0.058,0.131,0.0061,42963.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-21",24,24,7098,,0.015,0.001,2827.5,0.058,0.142,0.0058,48418.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-22",24,24,7368,,0.015,0.001,2921.8,0.058,0.153,0.0061,50027.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-23",23,22.8,6651.6,,0.014,0.001,2668.56,0.058,0.141,0.0062,45692.02,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-25",8,5.86,1246.16,,0.003,0.001,567.102,0.058,0.055,0.014,9708.71,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-26",24,24,5700,,0.012,0.001,2370.7,0.058,0.122,0.006,40594.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-27",24,24,6659,,0.014,0.001,2684,0.058,0.141,0.0061,45956.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-28",24,24,6512,,0.014,0.001,2634.6,0.058,0.139,0.0062,45109,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-29",24,24,5065,,0.011,0.001,2152.1,0.058,0.113,0.0061,36854.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-30",24,24,6907,,0.014,0.001,2767.7,0.058,0.144,0.0061,47391.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-10-31",24,24,6625,,0.014,0.001,2673.4,0.058,0.139,0.0061,45778.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-01",24,24,6843,,0.014,0.001,2759.2,0.058,0.139,0.0058,47245.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-02",24,24,6592,,0.014,0.001,2672.6,0.058,0.135,0.0058,45762.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-03",24,24,7351,,0.015,0.001,2923.1,0.058,0.15,0.006,50051.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-04",24,24,5639,,0.012,0.001,2356.3,0.058,0.12,0.006,40343.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-05",24,24,5793,,0.012,0.001,2418.9,0.058,0.124,0.006,41420.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-06",24,24,6797,,0.014,0.001,2744.5,0.058,0.143,0.0061,46996.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-07",24,24,6472,,0.013,0.001,2617.1,0.058,0.134,0.006,44813.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-08",24,24,6974,,0.014,0.001,2782.1,0.058,0.143,0.006,47639.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-09",24,24,7139,,0.015,0.001,2844,0.058,0.147,0.006,48696.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-10",24,24,7248,,0.015,0.001,2873.9,0.058,0.149,0.0061,49209.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-11",24,24,6617,,0.014,0.001,2665.4,0.058,0.138,0.006,45639.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-12",24,24,6974,,0.014,0.001,2775.2,0.058,0.143,0.006,47518.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-13",24,24,6267,,0.013,0.001,2550.7,0.058,0.133,0.0061,43672.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-14",24,24,5797,,0.012,0.001,2404.7,0.058,0.117,0.0055,41175.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-15",24,24,6666,,0.014,0.001,2687,0.058,0.132,0.0057,46015.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-16",24,24,6719,,0.014,0.001,2727.1,0.058,0.144,0.0062,46695.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-17",24,24,7168,,0.015,0.001,2853.3,0.058,0.147,0.006,48858.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-18",24,24,5267,,0.011,0.001,2227.9,0.058,0.116,0.0061,38149.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-19",24,24,7090,,0.015,0.001,2833.7,0.058,0.145,0.006,48521.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-20",24,24,6423,,0.013,0.001,2606.4,0.058,0.135,0.006,44629.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-21",24,24,6069,,0.013,0.001,2493.4,0.058,0.129,0.006,42692.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-22",24,24,6163,,0.013,0.001,2520,0.058,0.129,0.006,43152.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-23",24,24,6965,,0.014,0.001,2792.2,0.058,0.143,0.006,47813.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-24",24,24,6422,,0.013,0.001,2612.1,0.058,0.136,0.0061,44725.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-25",24,24,6508,,0.014,0.001,2643.6,0.058,0.136,0.006,45266.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-26",24,24,5760,,0.012,0.001,2401,0.058,0.124,0.006,41110.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-27",24,24,6172,,0.013,0.001,2531.1,0.058,0.134,0.0063,43339.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-28",24,24,6608,,0.014,0.001,2672.8,0.058,0.139,0.0061,45765.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-29",24,24,6477,,0.014,0.001,2637.7,0.058,0.138,0.0061,45165.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-11-30",24,24,7324,,0.015,0.001,2911,0.058,0.151,0.006,49843,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-01",24,24,7276,,0.015,0.001,2899.1,0.058,0.148,0.006,49639,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-02",24,24,7128,,0.015,0.001,2842.9,0.058,0.151,0.0062,48676.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-03",24,24,6996,,0.014,0.001,2789.4,0.058,0.146,0.0061,47763.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-04",24,24,7414,,0.015,0.001,2941.1,0.058,0.152,0.006,50360.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-05",24,24,6669,,0.014,0.001,2698,0.058,0.141,0.0061,46199.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-06",24,24,6399,,0.013,0.001,2608.8,0.058,0.137,0.0062,44668,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-07",24,24,5452,,0.012,0.001,2293.5,0.058,0.12,0.0061,39271.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-08",24,24,7348,,0.015,0.001,2957.1,0.058,0.155,0.0061,50635,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-09",24,24,7254,,0.015,0.001,2894.7,0.058,0.149,0.006,49571.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-10",24,24,7159,,0.015,0.001,2857.3,0.058,0.148,0.0061,48929,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-11",24,24,7320,,0.015,0.001,2915.6,0.058,0.15,0.006,49923.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-12",24,24,7225,,0.015,0.001,2884.8,0.058,0.149,0.006,49401.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-13",24,24,6734,,0.014,0.001,2718.5,0.058,0.138,0.0059,46545.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-14",24,24,6510,,0.014,0.001,2649.2,0.058,0.134,0.0059,45363,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-15",24,24,7486,,0.015,0.001,2973.2,0.058,0.158,0.0062,50910.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-16",24,24,7269,,0.015,0.001,2925.4,0.058,0.15,0.006,50093.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-17",24,24,6587,,0.014,0.001,2693.1,0.058,0.138,0.006,46113.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-18",24,24,6022,,0.013,0.001,2511.2,0.058,0.13,0.006,42998.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-19",24,24,6020,,0.013,0.001,2512.4,0.058,0.131,0.0061,43019.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-20",24,24,6051,,0.013,0.001,2522.6,0.058,0.128,0.0059,43193.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-21",24,24,5948,,0.013,0.001,2489.7,0.058,0.129,0.006,42629.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-22",24,24,7050,,0.015,0.001,2852.7,0.058,0.146,0.006,48849.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-23",24,24,6539,,0.014,0.001,2680.4,0.058,0.138,0.006,45895,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-24",24,24,7094,,0.015,0.001,2868.2,0.058,0.15,0.0061,49117,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-25",24,24,6231,,0.013,0.001,2583.7,0.058,0.133,0.006,44237.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-26",24,24,5555,,0.012,0.001,2365.2,0.058,0.12,0.006,40498.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-27",24,24,5399,,0.012,0.001,2306.3,0.058,0.119,0.006,39491.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-28",24,24,7005,,0.015,0.001,2834.4,0.058,0.148,0.0061,48532.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-29",24,24,6540,,0.014,0.001,2680.3,0.058,0.137,0.006,45898.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-30",24,24,7263,,0.015,0.001,2918.2,0.058,0.15,0.006,49972.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"4",,"2020-12-31",24,24,6931,,0.014,0.001,2812.4,0.058,0.143,0.0059,48157.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-02",4,3.65,335.81,,0.001,0.001,184.304,0.058,0.018,0.013,3156.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-06",5,4.16,394.6,,0.001,0.001,212.548,0.058,0.02,0.0134,3638.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-08",6,5.13,476.22,,0.001,0.001,265.196,0.058,0.022,0.012,4543.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-10",6,4.69,444.95,,0.001,0.001,241.637,0.058,0.02,0.0117,4139.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-11",9,7.81,761.25,,0.002,0.001,407.95,0.058,0.032,0.0123,6986.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-12",1,0.5,15.5,,0,0.001,17.25,0.058,0.008,0.052,295.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-16",9,7.41,739.81,,0.002,0.001,387.128,0.058,0.025,0.0106,6626.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-17",5,3.92,352.12,,0.001,0.001,199.964,0.058,0.02,0.019,3424.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-21",11,9.33,876.19,,0.002,0.001,477.454,0.058,0.038,0.0095,8178.178,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-22",4,2.7,228.62,,0.001,0.001,134.234,0.058,0.015,0.0195,2299.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-23",13,10.63,1003.85,,0.003,0.001,546.338,0.058,0.041,0.0122,9356.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-24",3,1.85,133.75,,0,0.001,89.316,0.058,0.012,0.0217,1528.123,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-25",6,4.3,419.48,,0.001,0.0008,219.97,0.058,0.019,0.0085,3766.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-26",8,6.61,648.67,,0.002,0.001,341.44,0.058,0.025,0.0111,5846.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-27",8,7.53,760.44,,0.002,0.001,392.198,0.058,0.029,0.0104,6716.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-28",12,10.7,993.11,,0.003,0.001,546.448,0.058,0.046,0.0107,9353.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-29",12,9.96,956.03,,0.003,0.001,513.412,0.058,0.043,0.0121,8792.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-30",8,6.95,665.61,,0.002,0.001,357.078,0.058,0.027,0.011,6115.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-01",9,7.79,756.13,,0.002,0.001,399.211,0.058,0.027,0.0096,6833.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-04",5,3.51,322.76,,0.001,0.001,175.548,0.058,0.024,0.0188,3005.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-05",8,7.98,828.1,,0.002,0.001,418.91,0.058,0.03,0.0086,7171.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-06",1,0.57,26.22,,0,0.001,24.339,0.058,0.004,0.021,416.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-07",3,2.77,248.52,,0.001,0.001,135.843,0.058,0.014,0.0123,2326.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-12",9,6.94,634.94,,0.002,0.001,344.882,0.058,0.032,0.0129,5907.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-14",2,1.17,57.82,,0,0.001,51.147,0.058,0.009,0.02,875.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-15",5,4.38,406.43,,0.001,0.001,221.593,0.058,0.02,0.0122,3797.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-17",3,2.5,211.83,,0.001,0.001,122.361,0.058,0.014,0.015,2095.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-18",8,7.46,740.38,,0.002,0.001,379.53,0.058,0.03,0.0103,6499.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-19",8,7.65,755.62,,0.002,0.001,393.892,0.058,0.033,0.0104,6743.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-24",8,7,671.42,,0.002,0.001,358.093,0.058,0.029,0.0113,6133.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-25",6,5.09,470.09,,0.001,0.001,261.716,0.058,0.019,0.0098,4480.439,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-26",5,4.25,388.31,,0.001,0.001,214.794,0.058,0.019,0.0138,3677.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-27",4,3.87,372.21,,0.001,0.001,197.091,0.058,0.018,0.0113,3376.189,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-03",7,6.71,659.21,,0.002,0.001,340.84,0.058,0.026,0.0094,5835.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-11",9,8.42,638.71,,0.002,0.001,348.627,0.0581,0.032,0.0127,5970.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-12",9,8.5,847.5,,0.002,0.001,430.35,0.058,0.033,0.011,7368.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-13",11,9.98,889.84,,0.002,0.001,462.572,0.058,0.033,0.0092,7921.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-16",12,11.25,1121.17,,0.003,0.001,584.852,0.058,0.043,0.0093,10015.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-21",2,1.28,100.48,,0,0.001,59.428,0.058,0.008,0.013,1018.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-11",2,0.77,0,,0,0.001,5.817,0.058,0.005,0.0945,99.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-12",7,4.92,258.51,,0.001,0.001,159.032,0.0581,0.014,0.0114,2722.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-14",7,6.22,633.52,,0.002,0.001,334.078,0.058,0.023,0.0129,5719.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-15",7,6.38,639.5,,0.002,0.001,337.846,0.058,0.02,0.0073,5785.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-16",4,3.01,276.11,,0.001,0.001,152.397,0.0583,0.014,0.0098,2610.029,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-17",7,6.42,645.12,,0.002,0.001,345.336,0.058,0.026,0.012,5913.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-18",2,1.93,182.19,,0.001,0.001,98.482,0.058,0.006,0.0075,1686.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-21",10,8.73,520.99,,0.002,0.001,312.978,0.058,0.022,0.01,5358.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-28",5,5,0,,0,0.001,13,0.059,0.002,0.016,221,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-29",11,10.15,610.76,,0.002,0.001,333.95,0.0584,0.023,0.012,5716.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-11",6,5.07,501.35,,0.001,0.001,266.905,0.058,0.018,0.011,4571.467,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-16",3,2.03,173.23,,0.001,0.001,101.276,0.058,0.012,0.0117,1734.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-17",4,3.07,294.4,,0.001,0.001,158.058,0.058,0.014,0.0088,2706.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-18",3,1.43,112.13,,0,0.001,67.915,0.0583,0.006,0.01,1162.361,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-23",6,3.48,289.01,,0.001,0.001,168.757,0.0583,0.023,0.02,2888.642,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-10",12,11.56,1168.54,,0.003,0.001,619.438,0.058,0.041,0.0083,10607.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-12",10,9.05,906.03,,0.002,0.001,481.683,0.0581,0.032,0.0079,8247.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-14",9,8.52,848.44,,0.002,0.001,453.664,0.058,0.031,0.0088,7771.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-15",8,6.81,663.62,,0.002,0.001,360.299,0.058,0.027,0.0098,6169.661,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-18",5,3.25,313.48,,0.001,0.001,165.116,0.058,0.012,0.01,2827.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-20",6,5.18,509.7,,0.001,0.001,268.714,0.058,0.02,0.0087,4601.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-21",5,4.35,399.85,,0.001,0.001,223.837,0.058,0.018,0.0096,3833.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-25",4,2.46,216.51,,0.001,0.001,123.066,0.058,0.01,0.0138,2108.199,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-26",9,7.54,747.12,,0.002,0.001,398.316,0.058,0.029,0.0103,6819.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-27",15,14.15,1430.2,,0.004,0.001,750.77,0.058,0.052,0.0085,12856.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-28",18,16.2,1670.7,,0.004,0.001,861.117,0.0581,0.056,0.0089,14746.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-29",7,5.89,578.21,,0.002,0.001,307.143,0.0581,0.024,0.009,5257.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-30",10,8.25,833.7,,0.002,0.001,432.805,0.0581,0.029,0.0105,7410.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-07-31",5,3.97,353.54,,0.001,0.001,200.596,0.058,0.019,0.0172,3435.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-03",2,1.64,121.46,,0,0.001,78.212,0.058,0.008,0.012,1339.113,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-04",7,5.75,551.2,,0.002,0.001,301.184,0.058,0.022,0.0093,5156.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-09",4,3.1,304,,0.001,0.001,158.08,0.058,0.015,0.009,2707.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-10",5,3.99,362.3,,0.001,0.001,204.862,0.058,0.018,0.011,3507.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-11",3,2.4,209.08,,0.001,0.001,119.756,0.058,0.013,0.012,2049.601,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-13",7,6.68,658.52,,0.002,0.001,349.82,0.058,0.025,0.0087,5992.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-14",11,9.62,958.7,,0.003,0.001,509.238,0.058,0.034,0.0109,8719.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-15",12,10.56,1025.34,,0.003,0.001,544.201,0.058,0.038,0.0093,9319.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-16",10,8.05,822,,0.002,0.0009,425.203,0.0581,0.031,0.0069,7281.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-17",8,7.3,703.33,,0.002,0.001,383.09,0.058,0.028,0.0095,6558.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-18",10,8.98,840.01,,0.002,0.001,452.173,0.058,0.03,0.0095,7742.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-19",8,6.8,665.68,,0.002,0.001,356.032,0.058,0.024,0.0081,6096.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-20",6,5.53,531.49,,0.001,0.001,286.373,0.058,0.02,0.0092,4903.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-21",8,7.07,687.25,,0.002,0.001,369.497,0.058,0.025,0.0105,6329.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-22",5,2.79,232.22,,0.001,0.001,136.386,0.058,0.015,0.01,2335.222,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-23",10,8.82,888.6,,0.002,0.0009,466.976,0.0581,0.031,0.0073,7996.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-24",10,8.85,869.04,,0.002,0.001,466.177,0.058,0.033,0.01,7981.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-25",10,8.73,862.26,,0.002,0.001,460.205,0.058,0.032,0.0119,7877.481,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-26",9,8.18,818.66,,0.002,0.001,430.973,0.058,0.03,0.0122,7380.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-27",7,5.69,493.2,,0.001,0.001,281.407,0.058,0.028,0.015,4819.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-02",10,9.05,929,,0.002,0.001,479.675,0.058,0.032,0.0073,8215.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-03",4,3.52,315.24,,0.001,0.001,180.712,0.058,0.016,0.0115,3094.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-04",7,5.07,508,,0.001,0.0007,261.481,0.0583,0.021,0.007,4478.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-05",10,8.69,856.32,,0.002,0.001,454.97,0.058,0.032,0.0101,7788.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-06",9,8.21,823.15,,0.002,0.001,430.779,0.058,0.03,0.0118,7376.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-07",7,5.93,562,,0.002,0.001,308.984,0.058,0.024,0.0104,5291.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-09",6,4.96,481.25,,0.001,0.001,254.541,0.058,0.019,0.008,4358.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-14",8,6.7,648.12,,0.002,0.001,347.482,0.058,0.025,0.0109,5950.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-16",7,5.42,528.32,,0.001,0.001,280.504,0.0581,0.021,0.0109,4803.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-17",14,12.2,1256.51,,0.003,0.001,646.15,0.058,0.044,0.0074,11062.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-18",12,10.31,1046.91,,0.003,0.001,544.974,0.058,0.037,0.0103,9336.179,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-19",10,9.75,979.7,,0.003,0.001,513.898,0.058,0.037,0.0088,8799.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-20",7,6.97,720.21,,0.002,0.001,369.615,0.058,0.027,0.0089,6328.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-21",2,1.38,114.5,,0,0.001,67.946,0.058,0.004,0.008,1162.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-22",9,8.12,788.84,,0.002,0.001,427.156,0.058,0.029,0.0083,7314.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-23",5,4.1,405.1,,0.001,0.001,211.856,0.058,0.018,0.0086,3628.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-24",9,8.11,800.43,,0.002,0.001,425.505,0.058,0.031,0.0089,7286.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-28",4,3.12,276.56,,0.001,0.001,156.352,0.058,0.014,0.0105,2677.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-29",5,3.85,367.4,,0.001,0.0008,194.955,0.0582,0.015,0.0078,3339.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-09-30",3,2.29,177.59,,0.001,0.001,113.124,0.058,0.012,0.0133,1937.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-01",8,6.88,674.92,,0.002,0.001,360.3,0.058,0.027,0.0091,6170.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-02",8,7.62,748.96,,0.002,0.001,397.337,0.058,0.027,0.0083,6803.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-03",11,10.13,1023.43,,0.003,0.001,531.577,0.058,0.037,0.0083,9104.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-04",7,5.75,559.34,,0.002,0.001,296.378,0.058,0.023,0.0091,5075.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-05",11,9.77,984.96,,0.003,0.001,512.664,0.0581,0.037,0.0082,8779.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-06",7,5.99,573.29,,0.002,0.001,310.285,0.058,0.024,0.0099,5313.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-11",1,0.75,14.25,,0,0.001,15.525,0.058,0.003,0.02,266.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-12",5,2.63,139.41,,0,0.001,89.589,0.058,0.007,0.0104,1533.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-13",5,3.74,345.72,,0.001,0.001,190.714,0.058,0.016,0.0098,3266.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-16",10,8.85,529.52,,0.002,0.001,307.171,0.0577,0.028,0.0117,5263.017,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-17",4,3.01,182.7,,0.001,0.001,101.216,0.0578,0.012,0.0095,1734.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-25",2,1.31,21.41,,0,0.001,25.884,0.0585,0.004,0.018,442.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-27",4,2.86,214.86,,0.001,0.001,122.504,0.0583,0.011,0.009,2097.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-02",5,3.64,334.78,,0.001,0.001,182.631,0.058,0.014,0.0102,3126.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-04",2,0.88,36.6,,0,0.001,36.876,0.058,0.005,0.0135,631.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-05",7,6.98,710.22,,0.002,0.001,361.264,0.058,0.027,0.0089,6186.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-10",4,3.08,277.89,,0.001,0.001,155.316,0.058,0.013,0.0175,2660.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-11",3,2.08,154.62,,0.001,0.001,101.84,0.058,0.01,0.0137,1743.153,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-12",4,2.39,214.76,,0.001,0.001,115.991,0.0583,0.011,0.0088,1986.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-20",2,1,66.08,,0,0.001,42.852,0.058,0.008,0.0135,734.185,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-28",2,1.04,46.9,,0,0.001,45.162,0.058,0.007,0.0165,772.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-01",7,5.41,402.46,,0.001,0.001,222.782,0.058,0.015,0.0106,3813.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-02",13,12.03,1139.91,,0.003,0.001,598.403,0.058,0.039,0.0092,10243.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-18",4,1.53,29.22,,0,0.001,30.176,0.0583,0.007,0.0243,517.619,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-19",1,0.08,0,,0,0.001,0.544,0.058,0,0.007,9.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-21",9,7.76,758.72,,0.002,0.001,405.852,0.058,0.028,0.0106,6947.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-29",2,1.6,120.64,,0,0.001,77.248,0.058,0.009,0.012,1322.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"6",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-08",3,2.5,192.46,,0.001,0.001,108.15,0.0583,0.009,0.015,1851.062,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-12",2,1.1,77.42,,0,0.001,49.124,0.058,0.009,0.0255,841.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-13",5,3.58,330.5,,0.001,0.001,183.344,0.058,0.017,0.012,3140.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-14",8,7.95,819.4,,0.002,0.001,423.585,0.058,0.028,0.0079,7252.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-15",13,10.29,967.31,,0.003,0.001,527.013,0.058,0.039,0.0112,9026.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-16",4,2.93,259.41,,0.001,0.001,147.689,0.058,0.012,0.0185,2527.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-17",10,9.42,960.54,,0.003,0.001,502.988,0.058,0.035,0.0098,8612.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-18",9,8.18,840.72,,0.002,0.001,433.252,0.0581,0.026,0.0071,7417.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-20",9,8.92,919.96,,0.002,0.001,473.14,0.058,0.033,0.0082,8103.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-21",2,1.02,91,,0,0.0005,47.636,0.0585,0.003,0.0035,815.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-22",8,7.9,812.4,,0.002,0.001,419.14,0.058,0.03,0.0085,7177.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-23",4,3.25,258.9,,0.001,0.001,157.275,0.058,0.014,0.0108,2692.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-24",2,1.67,147.21,,0,0.001,86.397,0.058,0.013,0.0205,1480.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-25",2,1.58,132.26,,0,0.001,78.498,0.058,0.007,0.0115,1345.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-30",3,1.95,174.88,,0,0.001,95.08,0.0583,0.009,0.0077,1627.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-01-31",8,7.78,776.68,,0.002,0.001,407.411,0.058,0.03,0.0089,6975.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-03",8,7.72,783.96,,0.002,0.001,411.156,0.058,0.03,0.0094,7037.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-04",6,3.52,252.29,,0.001,0.001,157.787,0.058,0.017,0.0245,2700.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-06",7,5.49,531.74,,0.001,0.0009,284.308,0.0581,0.022,0.0097,4868.729,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-07",3,2.16,186.12,,0.001,0.001,112.079,0.058,0.012,0.021,1919.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-11",11,10.07,1048,,0.003,0.001,536.083,0.0581,0.037,0.0079,9179.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-12",2,0.79,23.51,,0,0.001,31.648,0.058,0.008,0.032,541.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-13",9,8.08,833,,0.002,0.001,424.444,0.0581,0.025,0.0063,7269.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-27",5,3.72,337.02,,0.001,0.001,191.499,0.058,0.017,0.0134,3279.537,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-04",8,6.38,612.48,,0.002,0.001,389.994,0.058,0.03,0.0093,6678.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-05",19,18.83,1954.4,,0.005,0.001,1014.266,0.058,0.067,0.0079,17366.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-06",1,0.53,21.73,,0,0.001,22.048,0.058,0.001,0.007,377.201,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-28",6,4.62,439.44,,0.001,0.001,235.814,0.058,0.017,0.0085,4038.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-14",14,13.22,1325.04,,0.004,0.001,700.696,0.058,0.046,0.0084,11996.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-28",4,2.92,270.85,,0.001,0.001,147.476,0.058,0.017,0.011,2524.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-02",4,2.9,259.98,,0.001,0.001,146.63,0.058,0.017,0.0125,2512.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-05",12,10.45,1059.04,,0.003,0.001,557.476,0.058,0.035,0.0076,9545.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-07",10,8.3,473.48,,0.002,0.001,298.593,0.058,0.024,0.0109,5112.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-09",8,6.52,644.45,,0.002,0.001,341.525,0.058,0.025,0.0076,5847.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-16",7,6.11,608.42,,0.002,0.001,321.568,0.058,0.023,0.0079,5507.079,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-18",3,1.7,133.17,,0,0.001,82.294,0.058,0.01,0.0113,1410.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-20",5,4.82,481.96,,0.001,0.001,258.01,0.058,0.019,0.0088,4417.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-21",7,6.45,644.85,,0.002,0.001,343.555,0.058,0.021,0.0071,5883.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-22",6,4.42,421.47,,0.001,0.001,229.549,0.058,0.018,0.0112,3929.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-28",5,3.95,380.21,,0.001,0.001,204.013,0.0582,0.017,0.0086,3494.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-05-31",6,4.9,466.96,,0.001,0.001,256.935,0.058,0.017,0.013,4400.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-02",8,6.57,643.44,,0.002,0.001,347.617,0.058,0.025,0.0085,5952.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-10",10,8.97,909.96,,0.002,0.001,480.281,0.058,0.032,0.0071,8221.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-13",5,3.62,337.8,,0.001,0.0008,188.602,0.0548,0.018,0.0086,3230.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-14",5,3.23,309.05,,0.001,0.001,167.945,0.0582,0.013,0.011,2876.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-23",8,6.91,681,,0.002,0.001,366.794,0.0581,0.029,0.0093,6279.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-28",6,4.98,470.68,,0.001,0.001,261.384,0.058,0.02,0.0095,4475.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-06",9,7.87,784.96,,0.002,0.001,418.319,0.0581,0.028,0.0072,7163.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-11",13,11.41,1157.81,,0.003,0.001,614.039,0.058,0.038,0.0088,10512.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-14",10,8.57,854.44,,0.002,0.001,457.86,0.058,0.03,0.0078,7838.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-17",3,1.73,141.6,,0,0.001,84.298,0.058,0.008,0.007,1443.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-19",3,1.45,112.76,,0,0.001,68.2,0.058,0.008,0.0077,1167.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-21",7,6.42,628.7,,0.002,0.001,336.826,0.058,0.023,0.0097,5767.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-26",9,6.59,583.59,,0.002,0.001,336.706,0.058,0.028,0.0127,5765.007,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-27",4,3.67,335.1,,0.001,0.001,186.996,0.058,0.019,0.0135,3201.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-29",8,7,685,,0.002,0.001,367.25,0.058,0.028,0.009,6289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-30",9,7.98,809.8,,0.002,0.001,419.288,0.0581,0.031,0.0076,7180.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-07-31",5,3.51,320.68,,0.001,0.001,181.949,0.0582,0.017,0.0138,3116.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-01",3,0.41,10.5,,0,0.001,15.536,0.058,0.003,0.0107,266.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-02",11,9.98,1016.18,,0.003,0.001,530.506,0.058,0.034,0.0107,9084.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-04",6,4.28,420.02,,0.001,0.001,221.406,0.0582,0.016,0.0087,3790.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-05",2,1.21,66.63,,0,0.001,55.823,0.058,0.005,0.0125,956.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-10",6,4.44,350.44,,0.001,0.001,218.646,0.058,0.021,0.012,3743.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-12",10,8.65,863.32,,0.002,0.001,457.106,0.058,0.03,0.0077,7826.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-13",10,8.96,908.68,,0.002,0.001,474.136,0.0581,0.033,0.0077,8115.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-14",9,8.39,827.34,,0.002,0.001,443.472,0.058,0.031,0.0098,7592.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-15",12,10.1,1001.16,,0.003,0.0009,521.604,0.0581,0.035,0.0075,8932.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-16",8,6.47,637.71,,0.002,0.001,340.416,0.0581,0.025,0.0113,5829.383,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-18",1,0.02,0,,0,0,0.002,0.042,0,0,0.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-19",3,2.3,191.84,,0.001,0.001,113.176,0.058,0.008,0.0097,1937.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-21",8,6.53,639.16,,0.002,0.001,341.617,0.058,0.023,0.0095,5851.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-22",9,7.92,767.6,,0.002,0.001,418.976,0.058,0.027,0.0081,7170.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-23",9,8.65,858.7,,0.002,0.001,458.13,0.058,0.03,0.0077,7845.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-24",8,7.25,696.65,,0.002,0.001,380.57,0.058,0.028,0.0096,6517.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-25",8,7.11,683.99,,0.002,0.001,372.456,0.058,0.027,0.0109,6379.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-26",9,7.51,741.11,,0.002,0.001,395.35,0.058,0.027,0.0118,6769.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-27",4,1.38,100.31,,0,0.001,60.277,0.058,0.005,0.0128,1031.867,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-02",9,8.3,820.1,,0.002,0.001,439.43,0.058,0.03,0.0096,7523.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-04",5,3.97,389.35,,0.001,0.0008,203.584,0.058,0.016,0.0078,3487.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-06",10,8.98,878.24,,0.002,0.001,471.282,0.058,0.03,0.0078,8070.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-07",5,4.6,437.97,,0.001,0.001,237.659,0.058,0.019,0.0094,4069.591,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-09",1,0.07,0,,0,0.001,0.329,0.058,0,0.014,5.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-10",2,1.22,77.14,,0,0.001,55.628,0.058,0.004,0.0105,952.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-12",2,0.97,72,,0,0.001,42.319,0.058,0.008,0.012,724.263,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-16",9,8.11,818.42,,0.002,0.001,425.239,0.058,0.029,0.0074,7281.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-18",18,16.2,1669.48,,0.004,0.001,863.188,0.0581,0.052,0.0073,14782.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-19",12,10.6,1063.66,,0.003,0.001,560.504,0.0581,0.038,0.0091,9597.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-21",7,5.57,540.5,,0.001,0.001,289.869,0.058,0.02,0.0081,4963.921,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-22",6,5.13,488.2,,0.001,0.001,266.98,0.058,0.021,0.0093,4570.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-23",4,3.29,283.97,,0.001,0.001,168.36,0.058,0.015,0.0125,2882.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-24",10,8.25,837.4,,0.002,0.0009,433.72,0.058,0.031,0.0071,7421.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-25",8,6.85,667.41,,0.002,0.001,358.791,0.058,0.027,0.0093,6144.679,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-28",2,0.98,13.72,,0,0.001,18.662,0.0585,0.003,0.0135,319.354,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-29",4,1.49,57,,0,0.001,50.786,0.058,0.007,0.0195,869.258,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-09-30",7,5.5,531.5,,0.001,0.001,285.375,0.058,0.02,0.0124,4886.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-01",8,7.23,695.62,,0.002,0.001,378.78,0.058,0.028,0.0091,6485.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-02",10,8.97,910.88,,0.002,0.001,470.419,0.058,0.031,0.007,8055.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-03",11,9.25,942.05,,0.002,0.001,484.83,0.058,0.03,0.0082,8301.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-04",7,5.75,559.34,,0.002,0.001,297.131,0.0581,0.022,0.0089,5086.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-05",10,9.11,892.46,,0.002,0.001,465.667,0.058,0.03,0.0077,7973.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-07",6,5.58,534.69,,0.001,0.001,287.864,0.058,0.023,0.0095,4929.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-08",6,4.34,422.21,,0.001,0.001,223.087,0.058,0.016,0.0122,3820.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-10",1,1,0,,0,0.001,1.9,0.06,0.001,0.045,31.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-11",1,0.67,11.39,,0,0.001,13.668,0.058,0.003,0.027,234.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-12",7,4.51,411.89,,0.001,0.001,223.224,0.0581,0.017,0.012,3823.231,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-13",7,5.92,560.8,,0.002,0.001,308.938,0.058,0.023,0.0117,5290.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-14",5,4.13,390.01,,0.001,0.001,214.493,0.058,0.016,0.0156,3674.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-16",5,4.21,411.15,,0.001,0.001,216.694,0.058,0.016,0.008,3711.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-17",4,2.18,207,,0.001,0.001,108.969,0.0583,0.012,0.0073,1866.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-18",4,2.76,232.24,,0.001,0.001,139.822,0.058,0.013,0.0175,2393.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-23",4,2.02,126.68,,0,0.001,85.165,0.058,0.009,0.0165,1458.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-26",6,4.52,429.23,,0.001,0.001,232.882,0.058,0.016,0.0128,3987.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-27",4,2.77,208.84,,0.001,0.001,128.229,0.058,0.013,0.0138,2195.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-02",6,4.53,429.16,,0.001,0.001,230.29,0.058,0.018,0.015,3943.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-03",6,5.85,576.47,,0.002,0.001,298.949,0.058,0.023,0.0095,5118.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-04",5,4,395.22,,0.001,0.0008,202.266,0.0554,0.019,0.0088,3463.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-06",4,3.62,328.75,,0.001,0.001,181.817,0.058,0.013,0.0088,3112.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-11",2,1.05,23.4,,0,0.001,28.155,0.058,0.004,0.0175,481.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-18",14,12.56,1112.97,,0.003,0.001,588.429,0.058,0.038,0.0076,10075.347,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-01",7,5.38,400.3,,0.001,0.001,220.672,0.0581,0.016,0.0106,3776.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-02",11,10.35,959.92,,0.003,0.001,512.55,0.058,0.034,0.0082,8774.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-14",3,1.57,122.5,,0,0.001,73.197,0.058,0.009,0.01,1254.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-22",3,1.26,100.98,,0,0.001,57.628,0.0583,0.005,0.0177,986.276,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Scattergood Generating Station",404,"7",,"2020-12-31",11,9.97,1012.29,,0.003,0.001,528.49,0.058,0.038,0.009,9050.132,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-28",5,3.93,151.29,,0,0.001,94.581,0.058,0.019,0.0398,1621.618,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-01-31",5,4.09,167.37,,0.001,0.001,98.978,0.058,0.019,0.0282,1694.923,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-03",4,3.48,143.16,,0,0.001,85.884,0.058,0.012,0.0228,1471.96,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-04",9,7.98,333.34,,0.001,0.001,197.335,0.058,0.029,0.0188,3382.597,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-05",9,7.56,299.76,,0.001,0.001,184.395,0.058,0.025,0.0188,3157.701,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-06",3,1.43,47.18,,0,0.001,32.388,0.058,0.006,0.0273,554.851,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-10",5,2.35,73.75,,0,0.0008,49.412,0.0584,0.015,0.0486,846.526,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-11",1,0.02,0,,0,0.001,0.08,0.058,0,0.005,1.374,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-12",2,1.33,35.06,,0,0.001,29.009,0.058,0.007,0.0255,497.108,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-15",3,1.88,62.9,,0,0.001,43.372,0.058,0.012,0.0307,743.224,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-17",3,2.33,80.06,,0,0.001,54.857,0.058,0.011,0.0293,940.092,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-18",6,4.71,192.49,,0.001,0.001,115.193,0.058,0.018,0.0173,1975.909,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-09",9,8.17,345.93,,0.001,0.001,203.389,0.058,0.039,0.023,3486.565,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-16",6,5,197.13,,0.001,0.001,121.566,0.058,0.015,0.0232,2084.965,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-17",4,2.9,103.4,,0,0.001,68.644,0.058,0.012,0.027,1175.296,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-18",6,4.13,178,,0.001,0.001,102.028,0.0582,0.018,0.015,1747.529,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-23",2,1.17,35.54,,0,0.001,25.453,0.058,0.006,0.049,436.756,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-26",2,1.38,44.56,,0,0.001,30.796,0.058,0.008,0.0465,527.596,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-04",2,0.98,22.9,,0,0.001,20.717,0.058,0.005,0.0405,355.262,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-28",3,1.17,26.3,,0,0.001,22.795,0.0583,0.007,0.0293,390.758,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-05",8,6.35,276.1,,0.001,0.001,162.155,0.0581,0.025,0.0211,2779.705,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-14",3,2.23,72.72,,0,0.001,53.184,0.058,0.011,0.0253,911,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-25",4,2.45,95.07,,0,0.001,60.335,0.058,0.008,0.0148,1035.522,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-26",15,13.34,584.15,,0.002,0.001,342.98,0.058,0.051,0.0201,5877.991,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-28",4,2.72,96.84,,0,0.001,63.833,0.058,0.015,0.0418,1094.609,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-02",6,5.1,212.1,,0.001,0.001,127.13,0.058,0.024,0.0215,2178.96,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-03",8,6.45,267.07,,0.001,0.001,160.379,0.058,0.024,0.0205,2748.065,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-08",3,2.02,73.04,,0,0.001,48.588,0.058,0.011,0.0233,832.122,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-09",5,3.6,143.12,,0,0.001,90.684,0.058,0.014,0.027,1552.352,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-10",9,8.2,344.98,,0.001,0.001,207.714,0.058,0.03,0.021,3561.634,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-11",4,2.42,83.94,,0,0.001,58.002,0.0583,0.011,0.0225,994.087,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-15",4,2.36,91.26,,0,0.001,57.222,0.058,0.012,0.0275,979.604,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-16",3,1.71,57.49,,0,0.001,39.769,0.0583,0.009,0.023,680.909,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-22",5,3.58,141.62,,0,0.001,89.38,0.058,0.015,0.0218,1532.106,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-23",6,5.28,221.12,,0.001,0.001,134.001,0.058,0.02,0.0178,2295.73,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-24",5,4.87,208.14,,0.001,0.001,124.003,0.058,0.023,0.0222,2127.798,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-06-30",6,4.28,137.25,,0,0.001,85.97,0.0583,0.01,0.0198,1473.849,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-06",10,8.79,386.1,,0.001,0.0009,228.046,0.0581,0.042,0.0231,3912.125,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-07",8,6.5,265.19,,0.001,0.001,167.489,0.058,0.032,0.0276,2869.021,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-08",3,2.08,17.86,,0,0.001,24.808,0.0583,0.007,0.03,424.938,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-10",12,11.05,489.94,,0.001,0.001,287.817,0.058,0.042,0.0186,4932.031,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-12",4,2.98,121.5,,0,0.001,73.492,0.0583,0.014,0.0185,1260.132,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-14",2,2,0,,0,0.001,3,0.057,0.006,0.241,52.4,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-13",6,5.67,245.21,,0.001,0.001,145.65,0.058,0.021,0.0177,2495.61,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-14",7,4.67,163.12,,0.001,0.001,105.65,0.0583,0.026,0.0387,1812.026,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-15",5,4.45,180.55,,0.001,0.001,113.128,0.058,0.016,0.0164,1939.79,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-17",4,3.87,162.23,,0,0.001,96.532,0.058,0.016,0.0205,1652.493,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-18",8,6.82,288.62,,0.001,0.001,173.034,0.058,0.024,0.0175,2965.645,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-19",4,2.58,98.68,,0,0.001,62.506,0.058,0.01,0.018,1070.908,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-23",8,6.98,303.54,,0.001,0.001,177.319,0.058,0.028,0.021,3039.891,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-24",6,4.81,201.81,,0.001,0.001,120.142,0.058,0.032,0.0347,2058.994,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-25",9,7.65,334.6,,0.001,0.001,196.784,0.0581,0.03,0.0209,3372.419,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-26",7,4.61,137.56,,0.001,0.001,103.843,0.058,0.038,0.0519,1779.612,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-27",3,3,0,,0,0.001,4.5,0.058,0.009,0.241,77.7,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-28",6,6,0,,0,0.001,9,0.058,0.019,0.241,155.4,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-04",2,0.96,27.9,,0,0.001,18.657,0.058,0.017,0.1735,319.986,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-05",6,4.8,203.33,,0.001,0.001,120.531,0.058,0.024,0.0232,2064.1,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-06",7,4.69,168.92,,0.001,0.001,111.773,0.058,0.022,0.0269,1914.944,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-16",7,5.73,233.71,,0.001,0.001,140.719,0.058,0.026,0.0294,2412.193,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-17",5,4.05,170.1,,0.001,0.001,98.24,0.0582,0.018,0.0186,1684.02,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-18",9,7.62,323.45,,0.001,0.001,188.111,0.058,0.033,0.0184,3226.228,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-19",7,6.35,267.85,,0.001,0.001,156.76,0.058,0.025,0.023,2685.435,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-20",10,8.87,390.24,,0.001,0.001,224.775,0.058,0.041,0.0208,3854.893,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-23",7,6.5,273.5,,0.001,0.001,163.05,0.058,0.024,0.0184,2794.925,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-29",5,2.88,98.04,,0,0.001,63.668,0.0582,0.018,0.0684,1090.98,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-09-30",3,2.02,75.73,,0,0.001,46.759,0.058,0.01,0.0207,802.636,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-01",4,2.85,104.33,,0,0.001,68.656,0.058,0.014,0.031,1176.496,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-02",5,4.05,165.1,,0.001,0.001,99.72,0.058,0.019,0.022,1708.83,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-03",8,6.72,284.91,,0.001,0.001,169.374,0.058,0.023,0.0208,2900.094,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-05",5,3.67,145.57,,0,0.001,88.608,0.058,0.017,0.022,1519.305,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-06",4,3.75,152.38,,0,0.001,92.411,0.058,0.019,0.0248,1584.465,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-07",6,4.32,182.89,,0.001,0.001,107.713,0.058,0.019,0.0167,1845.575,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-08",3,2.1,70.88,,0,0.001,50.254,0.058,0.01,0.0347,861.107,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-10",2,1.92,73.12,,0,0.001,44.452,0.058,0.012,0.032,761.736,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-11",6,5.9,256.4,,0.001,0.001,149.16,0.058,0.026,0.0215,2554.94,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-12",2,1.03,23.71,,0,0.001,21.963,0.058,0.005,0.0415,377.192,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-15",2,1.28,32.4,,0,0.001,28.64,0.058,0.011,0.04,490.842,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-19",13,11.88,509.58,,0.002,0.001,300.65,0.058,0.047,0.0195,5154.396,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-02",3,2.58,92.56,,0,0.001,60.733,0.058,0.016,0.033,1041.166,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-03",3,1.53,49.39,,0,0.001,34.174,0.0583,0.009,0.0353,585.021,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-05",5,4.26,165.92,,0.001,0.001,104.87,0.058,0.027,0.0348,1798.554,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-10",4,2.82,110.33,,0,0.001,67.587,0.058,0.016,0.0218,1160.291,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-13",5,1.88,39.63,,0,0.0006,24.31,0.0674,0.011,0.0978,411.427,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"5",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-01",24,24,4862,,0.01,0.001,2014.7,0.058,0.123,0.0071,34534.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-02",24,23.92,5027.52,,0.011,0.001,2082.892,0.058,0.128,0.0072,35700.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-03",24,24,5317,,0.011,0.001,2178.3,0.058,0.133,0.0071,37334.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-04",24,24,4958,,0.011,0.001,2048.3,0.058,0.126,0.0072,35107.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-05",24,24,5497,,0.011,0.001,2235.3,0.058,0.141,0.0073,38309,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-06",24,23.98,5090.9,,0.011,0.001,2087.822,0.058,0.137,0.0077,35788.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-07",24,24,5567,,0.012,0.001,2257.3,0.058,0.142,0.0073,38689.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-08",24,24,5194,,0.011,0.001,2125.4,0.058,0.131,0.0072,36428.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-09",24,24,4966,,0.011,0.001,2045.2,0.058,0.127,0.0072,35058.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-10",21,19.4,4030.62,,0.009,0.001,1684.027,0.058,0.114,0.0115,28864.777,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-16",2,0.4,0.6,,0,0.001,7.65,0.058,0.008,0.0855,131.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-17",2,0.69,3.64,,0,0.001,17.834,0.058,0.02,0.128,305.421,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-19",13,12.05,1708.1,,0.004,0.001,794.074,0.058,0.168,0.0457,13608.776,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-25",10,9.9,1625.7,,0.004,0.001,719.71,0.058,0.138,0.0429,12338.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-26",24,24,5887,,0.012,0.001,2337.7,0.058,0.139,0.007,40069.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-27",24,24,4832,,0.01,0.001,1956.4,0.0581,0.121,0.0073,33503.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-28",16,15.5,2748.5,,0.006,0.001,1180.75,0.058,0.199,0.0321,20232.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-29",17,15.93,3286.47,,0.007,0.001,1386.431,0.058,0.168,0.0245,23764.746,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-30",24,24,5231,,0.011,0.001,2125.1,0.058,0.127,0.007,36424.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-03-31",15,14.65,3132.4,,0.007,0.001,1303.385,0.058,0.16,0.0233,22340.135,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-01",7,6.93,1314.89,,0.003,0.001,546.617,0.058,0.038,0.0081,9368.554,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-04",3,2.22,29.2,,0,0.001,66.202,0.058,0.07,0.1177,1134.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-07",8,7.02,1358,,0.003,0.001,580.078,0.058,0.075,0.0375,9943.638,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-08",14,13.48,2255.4,,0.005,0.001,965.408,0.058,0.062,0.0085,16545.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-09",9,8.3,1500.2,,0.003,0.001,651.53,0.058,0.146,0.0436,11166.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-10",8,7.45,1336.8,,0.003,0.001,572.435,0.058,0.038,0.0091,9809.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-14",11,10.12,1310,,0.003,0.001,626.584,0.058,0.19,0.0544,10741.896,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-15",7,6.62,1151.08,,0.003,0.001,497.82,0.058,0.035,0.0091,8534.196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-23",12,11.32,1681.64,,0.004,0.001,770.328,0.058,0.2,0.0565,13204.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-24",24,23.97,5473.52,,0.011,0.001,2185.615,0.058,0.133,0.0071,37464.374,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-25",24,23.03,4737,,0.01,0.001,1940.305,0.058,0.122,0.0071,33255.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-26",12,10.78,2153.4,,0.005,0.001,921.941,0.058,0.123,0.0217,15800.701,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-28",13,11.12,2055.2,,0.005,0.001,881.892,0.058,0.125,0.0215,15112.716,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-29",7,6.1,1179.62,,0.003,0.001,508.311,0.058,0.073,0.0236,8712.391,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-06",7,5.76,1001.14,,0.002,0.001,447.65,0.058,0.096,0.0363,7670.246,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-07",9,7.82,1586.54,,0.003,0.001,664.572,0.058,0.077,0.0254,11390.07,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-10",8,7.17,1462,,0.003,0.001,619.177,0.058,0.09,0.0255,10612.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-11",21,20.35,4918,,0.01,0.001,1971.045,0.058,0.122,0.0081,33786.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-12",15,13.4,2055.75,,0.005,0.001,901.975,0.058,0.094,0.0145,15458.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-13",22,20.98,4942.08,,0.01,0.001,2028.759,0.058,0.159,0.0129,34770.333,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-26",16,15.92,2603.59,,0.006,0.001,1153.845,0.058,0.25,0.0463,19773.703,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-27",24,24,4790,,0.01,0.001,1967.5,0.058,0.12,0.0072,33724.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-28",24,23.3,4717.98,,0.01,0.001,1964.972,0.058,0.122,0.0082,33685.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-29",16,15.23,2843.69,,0.006,0.001,1209.181,0.058,0.152,0.0215,20728.666,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-30",3,2.9,451.1,,0.001,0.001,198.72,0.058,0.015,0.0093,3405.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-01",11,10.08,1703.68,,0.004,0.001,753.254,0.058,0.127,0.0335,12911.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-02",16,15.83,3520.09,,0.007,0.001,1457.031,0.058,0.145,0.0177,24973.011,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-03",19,17.61,3816.08,,0.008,0.0009,1592.637,0.0581,0.137,0.013,27299.553,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-04",23,22.03,4459,,0.01,0.001,1856.226,0.058,0.114,0.0069,31819.051,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-09",17,16.27,3033.54,,0.007,0.001,1305.842,0.058,0.187,0.0327,22382.051,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-10",24,24,5037,,0.011,0.001,2073.1,0.058,0.127,0.0072,35534.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-11",16,14.19,3023.68,,0.007,0.001,1270.638,0.058,0.128,0.0179,21777.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-24",13,11.8,1592.25,,0.004,0.001,762.705,0.058,0.2,0.049,13069.645,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-25",14,13.83,2846.06,,0.006,0.001,1188.653,0.058,0.128,0.0173,20374.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-26",13,12.58,2671.54,,0.006,0.001,1104.75,0.058,0.114,0.0203,18936.034,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-27",16,14.95,2877,,0.006,0.001,1215.77,0.058,0.119,0.0183,20838.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-28",8,6.87,1324.37,,0.003,0.001,567.596,0.058,0.087,0.0289,9730.533,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-29",24,24,5445,,0.011,0.001,2177.3,0.058,0.131,0.007,37321.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-06-30",16,13.53,2600.79,,0.006,0.001,1101.906,0.0579,0.129,0.0165,18888.573,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-01",10,8.67,1515.88,,0.004,0.001,686.045,0.058,0.089,0.0245,11758.791,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-02",10,9.1,1783.56,,0.004,0.001,755.482,0.058,0.113,0.0255,12949.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-03",9,8,1472.45,,0.003,0.001,647.776,0.058,0.12,0.0413,11102.706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-04",11,9.86,1775.86,,0.004,0.001,774.206,0.058,0.109,0.0303,13270.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-05",11,9.8,2073.24,,0.004,0.001,863.196,0.058,0.094,0.0239,14795.588,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-06",16,15.92,3475,,0.007,0.001,1442.596,0.058,0.136,0.015,24726.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-07",13,11.48,2194.56,,0.005,0.001,937.877,0.058,0.128,0.0277,16075.204,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-08",14,13.15,2569,,0.006,0.001,1075.285,0.058,0.122,0.0177,18428.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-09",22,21.72,4574.84,,0.01,0.001,1886.16,0.058,0.116,0.0073,32333.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-10",11,10.05,2288.68,,0.005,0.001,947.83,0.0581,0.096,0.0172,16245.188,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-11",24,23.98,5194.48,,0.011,0.001,2112.716,0.058,0.127,0.007,36208.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-12",16,14.83,3432.6,,0.007,0.001,1419.239,0.058,0.115,0.0131,24323.421,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-13",15,14.02,2948.07,,0.006,0.001,1241.595,0.058,0.106,0.0147,21280.089,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-14",14,12.89,2695.53,,0.006,0.001,1145.442,0.058,0.115,0.0159,19633.842,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-15",13,12.55,2456.4,,0.005,0.001,1060.28,0.058,0.117,0.0187,18173.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-17",10,8.32,1782.2,,0.004,0.001,758.246,0.058,0.092,0.0212,12995.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-18",8,6.83,1434.92,,0.003,0.001,594.2,0.058,0.077,0.0238,10182.121,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-19",13,11.65,2355.24,,0.005,0.001,978.11,0.058,0.085,0.0167,16765.536,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-20",13,12.93,2968.55,,0.006,0.001,1208.049,0.058,0.094,0.0123,20703.362,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-21",17,16.04,3331.99,,0.007,0.001,1391.749,0.058,0.119,0.0136,23853.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-22",8,6.3,1248.98,,0.003,0.001,519.252,0.058,0.064,0.0171,8900.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-24",10,9.02,1814.76,,0.004,0.001,754.942,0.058,0.088,0.0196,12939.498,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-25",11,10.17,2266,,0.005,0.001,911.964,0.058,0.086,0.0133,15632.345,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-26",21,19.6,4346.4,,0.009,0.001,1754.1,0.058,0.131,0.0104,30063.925,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-27",16,13.41,2811.55,,0.006,0.001,1146.811,0.0581,0.109,0.0236,19655.025,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-28",13,12.1,2627,,0.006,0.001,1077.67,0.058,0.094,0.0208,18470.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-29",24,23.37,5038.17,,0.011,0.001,2054.981,0.058,0.131,0.0081,35220.215,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-30",14,12.55,2733.37,,0.006,0.001,1129.586,0.058,0.107,0.0134,19363.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-07-31",16,15.42,3600,,0.007,0.001,1454.368,0.058,0.122,0.0136,24927.626,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-01",23,22.68,4739.16,,0.01,0.001,1933.56,0.058,0.119,0.0073,33143.048,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-02",11,9.67,2027.52,,0.004,0.001,842.74,0.058,0.086,0.0201,14442.027,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-03",16,14.92,3084.49,,0.007,0.001,1290.171,0.058,0.136,0.0168,22113.495,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-04",11,9.85,2143.71,,0.004,0.001,866.657,0.058,0.082,0.0167,14855.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-05",8,6.12,1229,,0.003,0.001,508.308,0.058,0.069,0.0159,8711.891,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-06",5,3.61,479,,0.001,0.001,220.785,0.0582,0.049,0.0332,3782.646,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-07",9,7.38,1531.9,,0.003,0.001,633.888,0.0581,0.076,0.0173,10864.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-08",9,8.09,1667.09,,0.004,0.001,694.725,0.058,0.078,0.021,11906.765,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-09",9,7.94,1636.79,,0.003,0.001,679.314,0.058,0.08,0.0164,11645.384,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-10",14,12.2,2457.36,,0.005,0.0009,1016.702,0.0581,0.116,0.0176,17425.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-11",10,8.93,1921.01,,0.004,0.001,786.98,0.058,0.079,0.0209,13490.73,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-12",11,9.48,2149.08,,0.005,0.001,878.028,0.058,0.095,0.0206,15048.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-13",16,16,3453,,0.007,0.001,1402.2,0.058,0.112,0.012,24035,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-14",15,13.6,3038.65,,0.006,0.001,1253.005,0.058,0.115,0.0145,21479.245,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-15",15,13.6,2956.83,,0.006,0.001,1218.084,0.058,0.105,0.0137,20878.987,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-16",24,24,4804,,0.01,0.001,1956.8,0.058,0.12,0.0072,33538.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-17",24,24,5085,,0.011,0.001,2052.6,0.058,0.124,0.0071,35181.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-18",24,24,4873,,0.01,0.001,1957.6,0.058,0.117,0.007,33551.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-19",24,24,5012,,0.01,0.001,2017,0.058,0.121,0.007,34573.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-20",24,24,4561,,0.009,0.001,1843.4,0.058,0.113,0.0072,31596.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-21",23,22.4,4481.4,,0.009,0.001,1805.78,0.058,0.112,0.0077,30951.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-22",14,13.27,2907.65,,0.006,0.001,1206.018,0.058,0.12,0.0171,20671.361,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-23",12,10.99,2443.71,,0.005,0.001,1017.964,0.058,0.096,0.0185,17448.522,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-24",14,12.93,2743.35,,0.006,0.001,1117.275,0.058,0.091,0.0119,19153.254,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-25",11,10.69,2333.35,,0.005,0.001,954.528,0.058,0.084,0.0167,16362.149,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-26",15,14.08,2847,,0.006,0.001,1166.012,0.058,0.103,0.0116,19988.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-27",24,24,4732,,0.01,0.001,1929.6,0.058,0.116,0.007,33074.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-28",24,23.98,4796.72,,0.01,0.001,1946.7,0.058,0.117,0.007,33369.506,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-29",24,24,4471,,0.009,0.001,1832.6,0.058,0.112,0.0072,31414.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-30",24,23.93,4283.83,,0.009,0.001,1774.43,0.058,0.112,0.0074,30414.294,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-08-31",11,10.25,1946.01,,0.004,0.001,816.042,0.058,0.103,0.0227,13984.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-01",12,10.6,2132.7,,0.005,0.001,882.435,0.058,0.098,0.0199,15125.525,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-02",14,13.25,2751.17,,0.006,0.001,1136.49,0.058,0.113,0.0171,19480.155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-04",15,14.43,2873.87,,0.006,0.001,1190.602,0.058,0.131,0.0228,20405.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-05",24,23.98,4765.14,,0.01,0.001,1936.498,0.058,0.119,0.0072,33192.258,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-06",24,24,4877,,0.01,0.001,1977.8,0.058,0.119,0.007,33894.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-07",24,24,5190,,0.011,0.001,2082.8,0.058,0.125,0.007,35694.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-08",24,24,4656,,0.01,0.001,1902.5,0.058,0.114,0.007,32609.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-09",24,24,4828,,0.01,0.001,1947.5,0.058,0.118,0.0071,33380.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-10",24,24,4384,,0.009,0.001,1794.4,0.058,0.108,0.007,30756.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-11",23,22.8,5013.4,,0.01,0.001,2002.46,0.058,0.127,0.0075,34326.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-12",11,10.1,1858.46,,0.004,0.001,788.486,0.058,0.111,0.0275,13511.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-13",10,9.35,1731.01,,0.004,0.001,736.551,0.058,0.111,0.0283,12621.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-14",14,13.38,2648.74,,0.006,0.001,1099.618,0.058,0.126,0.0201,18847.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-15",14,12.72,2644.04,,0.006,0.001,1089.846,0.058,0.129,0.0187,18681.786,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-16",13,12.03,2512.81,,0.005,0.001,1035.137,0.058,0.124,0.0237,17739.825,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-17",16,15.42,3257.78,,0.007,0.001,1323.862,0.058,0.138,0.0219,22689.192,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-18",24,24,5384,,0.011,0.001,2139.1,0.058,0.129,0.007,36660.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-19",24,24,5308,,0.011,0.001,2111.2,0.058,0.128,0.0071,36184.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-20",24,24,5045,,0.01,0.001,2027.4,0.058,0.127,0.0073,34746.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-21",22,21.92,4816.76,,0.01,0.001,1926.64,0.058,0.121,0.0074,33023.704,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-23",12,11.07,2093.47,,0.005,0.001,888.705,0.058,0.142,0.0337,15231.752,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-24",12,11.15,2274.75,,0.005,0.001,941.47,0.058,0.117,0.0225,16137.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-28",13,12.33,1974.99,,0.004,0.001,869.32,0.058,0.176,0.0458,14904.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-29",24,24,4847,,0.01,0.001,1959.9,0.058,0.117,0.007,33593.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-09-30",24,24,5419,,0.011,0.001,2149,0.058,0.13,0.007,36833.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-01",24,24,5191,,0.011,0.001,2076.9,0.058,0.126,0.0071,35597.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-02",24,24,5051,,0.01,0.001,2026.4,0.058,0.122,0.007,34733,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-03",24,24,4938,,0.01,0.001,1986.4,0.058,0.121,0.0071,34047.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-04",24,24,4866,,0.01,0.001,1963.8,0.058,0.118,0.007,33658.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-05",23,22.67,4695.96,,0.01,0.001,1897.026,0.058,0.117,0.0075,32514.069,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-06",13,12.05,2494.31,,0.005,0.001,1024.39,0.058,0.109,0.019,17557.768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-07",11,10.35,2031.7,,0.004,0.001,858.34,0.058,0.113,0.0237,14712.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-10",9,8.07,1357.47,,0.003,0.001,604.058,0.058,0.121,0.0412,10353.863,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-11",10,9.83,2025.09,,0.004,0.001,839.965,0.058,0.103,0.0223,14397.291,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-12",19,16.82,2923.67,,0.006,0.001,1242.741,0.058,0.135,0.0177,21300.623,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-13",8,7.82,1457,,0.003,0.001,623.991,0.058,0.12,0.0346,10696.799,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-14",10,9.35,1833.65,,0.004,0.001,774.935,0.058,0.123,0.0289,13283.685,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-15",12,10.63,2012.2,,0.004,0.0009,848.661,0.0581,0.122,0.0223,14544.949,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-16",12,10.29,2087.22,,0.004,0.001,858.319,0.058,0.107,0.0205,14711.049,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-19",11,10.63,2074.08,,0.004,0.001,874.194,0.058,0.118,0.0298,14984.548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-20",20,19.18,3765.8,,0.008,0.001,1545.56,0.058,0.094,0.0079,26490.004,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-22",18,17.02,2871.69,,0.006,0.001,1246.196,0.058,0.155,0.0234,21361.943,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-23",14,12.89,2526.17,,0.006,0.001,1074.031,0.058,0.141,0.0249,18403.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-24",24,24,4846,,0.01,0.001,1984.8,0.058,0.121,0.0071,34015.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-25",8,7.42,1725.06,,0.004,0.001,702.748,0.058,0.044,0.0086,12044.924,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-27",4,3.05,165.89,,0.001,0.001,128.523,0.058,0.111,0.0953,2202.435,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-01",13,12.08,2088,,0.005,0.001,905.608,0.0581,0.174,0.0477,15521.684,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-02",23,22.37,4797.54,,0.01,0.001,1935.473,0.058,0.119,0.0073,33178.938,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-03",13,12.52,2745.24,,0.006,0.001,1117.644,0.058,0.118,0.0233,19158.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-04",23,22.73,4988.89,,0.01,0.001,2010.837,0.058,0.123,0.0073,34465.269,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-05",13,11.85,2404.1,,0.005,0.001,1007.045,0.058,0.132,0.0305,17261.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-06",9,8.51,1613.27,,0.004,0.001,694.834,0.058,0.102,0.0303,11909.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"6",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-01",24,24,4879,,0.01,0.001,2014.8,0.058,0.119,0.0069,34536.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-02",24,24,5074,,0.011,0.001,2086.2,0.058,0.125,0.007,35755.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-03",24,24,5294,,0.011,0.001,2166.3,0.058,0.129,0.007,37129,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-04",24,24,4963,,0.011,0.001,2044,0.058,0.123,0.007,35033.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-05",24,24,5499,,0.011,0.001,2230.1,0.058,0.134,0.007,38223.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-06",24,23.98,5104.92,,0.011,0.001,2087.134,0.058,0.126,0.007,35778.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-07",24,24,5612,,0.012,0.001,2263.6,0.058,0.137,0.007,38798.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-08",24,24,5248,,0.011,0.001,2135.9,0.058,0.128,0.007,36610.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-09",24,24,5011,,0.011,0.001,2054.5,0.058,0.122,0.0069,35213.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-10",24,23.82,5006.88,,0.011,0.001,2099.308,0.058,0.131,0.0075,35979.706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-24",7,6.33,405.99,,0.001,0.001,279.015,0.058,0.183,0.09,4782.543,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-25",17,16.08,3308.52,,0.007,0.001,1412.6,0.058,0.142,0.0185,24212.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-26",10,8.72,1604.4,,0.004,0.001,709.862,0.058,0.123,0.0307,12168.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-27",7,6.07,1026.17,,0.002,0.001,479.505,0.058,0.112,0.0481,8218.985,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-28",8,6.47,1116.26,,0.003,0.001,514.71,0.058,0.122,0.0378,8822.323,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-26",6,5.72,1123,,0.003,0.001,494.664,0.058,0.094,0.0427,8477.944,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-27",24,24,4900,,0.01,0.001,2026.4,0.058,0.121,0.007,34734.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-28",13,11.78,2369.2,,0.005,0.001,1011.026,0.058,0.106,0.0156,17326.564,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-29",14,12.84,2919.97,,0.006,0.001,1231.638,0.058,0.116,0.0141,21109.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-30",13,11.59,2651.84,,0.006,0.001,1131.74,0.058,0.102,0.0173,19398.372,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-04",1,0.07,0,,0,0.001,0.602,0.059,0,0.001,10.262,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-05",9,8.72,1196.64,,0.003,0.001,596.379,0.058,0.162,0.0497,10220.648,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-06",24,24,4816,,0.011,0.001,2051.4,0.058,0.122,0.007,35161.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-07",17,16.68,3412.28,,0.008,0.001,1468.824,0.058,0.139,0.0142,25173.552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-08",10,9.47,1596.49,,0.004,0.001,705.58,0.058,0.045,0.0084,12092.549,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-23",7,6.18,1205,,0.003,0.001,526.608,0.058,0.097,0.0369,9026.866,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-24",24,23.97,5543.37,,0.012,0.001,2269.986,0.058,0.135,0.007,38909.551,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-25",1,0.67,66.33,,0,0.001,43.081,0.058,0.008,0.021,738.541,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-29",10,9.08,1577.02,,0.004,0.001,729.188,0.058,0.133,0.0374,12500.622,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-06",13,11.31,1476.54,,0.004,0.001,728.211,0.058,0.233,0.0582,12482.934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-07",11,10.45,1979.15,,0.004,0.001,869.28,0.058,0.127,0.0285,14900.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-10",11,10.63,1879.04,,0.004,0.001,852.096,0.058,0.162,0.0434,14602.267,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-11",24,24,5851,,0.012,0.001,2398.9,0.058,0.145,0.007,41113.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-12",18,17.68,3226.36,,0.007,0.001,1397.284,0.058,0.089,0.0077,23949.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-13",24,23.41,5423.14,,0.012,0.001,2288.603,0.058,0.193,0.0144,39223.983,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-14",8,7.13,1687.36,,0.004,0.001,707.96,0.058,0.044,0.0106,12134.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-26",10,9.92,2098.36,,0.005,0.001,889.416,0.058,0.116,0.0258,15243.664,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-27",14,11.52,2473.48,,0.005,0.0009,1050.118,0.0579,0.102,0.0151,17998.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-28",12,10.85,2461.5,,0.005,0.001,1055.67,0.058,0.093,0.0118,18094.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-29",13,11.92,2433.96,,0.005,0.001,1042.072,0.058,0.102,0.0192,17860.864,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-01",8,6.8,1219.2,,0.003,0.001,548.135,0.058,0.096,0.0321,9393.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-02",14,12.62,2879.1,,0.006,0.001,1228.779,0.058,0.119,0.0146,21060.232,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-03",14,13.8,3285.8,,0.007,0.001,1379.96,0.058,0.109,0.0137,23653.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-04",13,11.56,2541.76,,0.006,0.001,1112.668,0.058,0.104,0.015,19070.034,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-09",12,11.48,2552,,0.006,0.001,1089.562,0.058,0.15,0.0318,18672.945,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-10",13,12.05,2828.63,,0.006,0.001,1201.933,0.058,0.113,0.0175,20601.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-11",12,11.27,2618.29,,0.006,0.001,1122.142,0.058,0.111,0.0201,19232.526,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-24",5,4.76,836.36,,0.002,0.001,380.88,0.058,0.092,0.0462,6529.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-25",11,9.87,2134.43,,0.005,0.001,906.316,0.058,0.088,0.0195,15532.819,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-26",9,7.93,1682.25,,0.004,0.001,726.704,0.058,0.087,0.0243,12456.005,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-27",10,8.5,1771.2,,0.004,0.001,759.968,0.058,0.084,0.0168,13026.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-29",17,16.28,3126.92,,0.007,0.001,1345.484,0.058,0.143,0.0174,23061.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-06-30",10,8.77,1811.92,,0.004,0.001,780.906,0.058,0.085,0.0181,13383.216,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-01",7,5.9,1175.54,,0.003,0.001,516.59,0.058,0.073,0.0301,8853.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-03",7,5.54,1053.06,,0.002,0.001,467.566,0.058,0.092,0.0417,8015.274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-04",6,5.01,897.37,,0.002,0.001,402.457,0.058,0.075,0.0272,6897.306,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-05",12,11.81,2466.83,,0.005,0.001,1068.536,0.058,0.148,0.0245,18312.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-06",13,12.46,2835.2,,0.006,0.001,1210.736,0.058,0.112,0.016,20751.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-07",10,8.62,1806.04,,0.004,0.001,766.951,0.058,0.088,0.0259,13146.401,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-08",11,9.85,2025.33,,0.004,0.001,869.145,0.0581,0.105,0.0202,14899.259,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-09",11,10.7,2383.7,,0.005,0.001,1009.43,0.058,0.098,0.0186,17300.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-10",24,24,5156,,0.011,0.001,2185.2,0.058,0.132,0.007,37455.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-11",24,23.98,5244.42,,0.011,0.001,2182.062,0.058,0.132,0.007,37402.534,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-12",24,24,5160,,0.011,0.001,2178.1,0.058,0.131,0.007,37330.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-13",23,22.82,4882.04,,0.011,0.001,2072,0.058,0.128,0.0073,35515.336,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-14",12,11.27,2419,,0.005,0.001,1036.685,0.058,0.098,0.0163,17766.598,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-15",15,12.72,2546.86,,0.006,0.001,1116.962,0.058,0.108,0.0146,19148.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-16",13,12.07,2388.94,,0.005,0.001,1063.276,0.058,0.142,0.0291,18223.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-17",12,11.72,2447.22,,0.006,0.001,1080.775,0.058,0.128,0.0203,18527.398,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-18",14,13.1,2654,,0.006,0.001,1134.81,0.058,0.129,0.0176,19449.59,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-19",16,14.6,2819,,0.006,0.001,1217.536,0.058,0.13,0.0195,20871.544,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-20",24,24,5309,,0.011,0.001,2209.1,0.058,0.133,0.007,37862.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-21",17,16.1,3461.15,,0.008,0.001,1459.165,0.058,0.109,0.0124,25009.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-22",22,21.88,4151.88,,0.009,0.001,1772.696,0.058,0.106,0.007,30382.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-23",11,10.27,2002.81,,0.004,0.001,870.569,0.058,0.106,0.0221,14921.902,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-24",13,12.77,2409.16,,0.005,0.001,1041.048,0.058,0.122,0.0195,17843.302,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-25",14,13.57,2803.27,,0.006,0.001,1185.412,0.058,0.125,0.0211,20316.483,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-26",24,24,5357,,0.011,0.001,2199.3,0.058,0.132,0.007,37695.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-27",23,22.98,4760.18,,0.01,0.001,1980.802,0.058,0.124,0.0073,33949.914,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-28",13,12.25,2687.34,,0.006,0.001,1153.218,0.058,0.121,0.0202,19765.392,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-29",15,13.43,3150,,0.007,0.0009,1313.748,0.058,0.119,0.0163,22517.267,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-30",16,15.43,3324.87,,0.007,0.001,1402.903,0.058,0.127,0.0158,24046.387,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-07-31",23,22.38,5109.44,,0.011,0.001,2126.504,0.058,0.133,0.0079,36448.482,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-01",12,11.79,2584.97,,0.006,0.001,1090.891,0.058,0.098,0.0142,18696.237,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-02",13,12.4,2535.1,,0.006,0.001,1086.41,0.058,0.132,0.0258,18622.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-03",13,12.62,2756.48,,0.006,0.001,1155.642,0.058,0.106,0.0172,19804.738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-04",16,14.7,2905.8,,0.006,0.001,1250.004,0.058,0.126,0.0176,21424.347,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-05",10,9.05,1693.17,,0.004,0.001,750.088,0.058,0.109,0.0292,12855.055,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-06",14,12.83,2156.46,,0.005,0.001,969.132,0.058,0.125,0.0214,16611.568,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-07",11,10.57,2132.61,,0.005,0.001,920.706,0.058,0.12,0.0237,15777.458,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-08",13,12.57,2541.41,,0.006,0.001,1086.565,0.058,0.131,0.0255,18621.669,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-09",17,15.71,3267.41,,0.007,0.001,1392.901,0.058,0.123,0.0143,23872.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-10",10,8.32,1774.6,,0.004,0.001,742.272,0.058,0.09,0.0206,12722.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-11",13,12.31,2560.58,,0.006,0.001,1092.337,0.058,0.133,0.0246,18725.216,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-12",13,12.09,2555.98,,0.006,0.001,1100.81,0.058,0.146,0.0261,18869.669,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-13",19,18.22,3965.22,,0.009,0.001,1654.41,0.058,0.143,0.0138,28359.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-14",18,16.7,3561.93,,0.008,0.001,1519.182,0.058,0.157,0.02,26038.411,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-15",18,16.35,3486.68,,0.008,0.001,1480.294,0.0581,0.143,0.015,25372.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-16",24,24,4874,,0.01,0.001,2027.1,0.058,0.122,0.007,34744.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-17",24,24,5150,,0.011,0.001,2124.1,0.058,0.127,0.007,36407.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-18",24,24,4928,,0.01,0.001,2025.4,0.058,0.122,0.007,34715.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-19",24,24,5076,,0.011,0.001,2087.1,0.058,0.124,0.007,35775.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-20",24,24,4619,,0.01,0.001,1907.9,0.058,0.116,0.0071,32703.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-21",22,21.02,4313,,0.009,0.001,1763.258,0.058,0.109,0.0069,30224.604,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-22",13,12.12,2739.22,,0.006,0.001,1153.672,0.058,0.108,0.0163,19773.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-23",16,15.27,3262.08,,0.007,0.001,1386.082,0.058,0.131,0.0173,23754.593,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-24",24,24,5285,,0.011,0.001,2179.2,0.058,0.13,0.007,37353.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-25",24,24,5060,,0.011,0.001,2114.9,0.058,0.128,0.007,36251.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-26",14,13.7,2611.4,,0.006,0.001,1121.93,0.058,0.071,0.0076,19230.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-19",13,10.35,596.08,,0.002,0.001,433.621,0.058,0.3,0.0912,7434.178,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-20",5,3.9,536.77,,0.001,0.001,258.16,0.058,0.098,0.085,4426.178,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-23",14,12.83,2687.64,,0.006,0.001,1136.57,0.058,0.149,0.0231,19481.218,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-28",11,9.83,1197.58,,0.003,0.001,579.417,0.058,0.191,0.0591,9931.576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-29",15,13.95,2953.76,,0.006,0.001,1222.899,0.058,0.168,0.0245,20960.149,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Valley Generating Station",408,"7",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-01",21,20.05,343,,0.001,0.001,270.715,0.0594,0.034,0.0172,4555.71,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-06",19,18.13,363.69,,0.001,0.001,268.06,0.0594,0.046,0.0279,4512.069,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-07",22,20.23,336.8,,0.001,0.001,267.856,0.0593,0.042,0.0289,4506.384,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-08",20,18.17,321.24,,0.001,0.001,249.381,0.0593,0.041,0.0294,4198.525,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-09",15,12.7,232.3,,0.001,0.001,176.582,0.0593,0.031,0.0579,2969.989,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-10",6,2.53,36.18,,0,0.001,30.662,0.0595,0.013,0.0745,515.691,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-11",24,22.27,367,,0.001,0.001,293.552,0.0591,0.046,0.0262,4943.532,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-12",24,22.25,353.2,,0.001,0.001,288.16,0.0593,0.041,0.024,4847.435,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-13",1,0.08,0,,0,0.001,0.448,0.06,0,0.062,7.528,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-21",2,0.37,1.44,,0,0.001,2.82,0.059,0.004,0.1795,47.623,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-22",3,2.05,35,,0,0.001,27.8,0.0593,0.009,0.045,468.64,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-24",4,2.22,43.87,,0,0.001,32.285,0.0595,0.014,0.09,544.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-30",4,2.5,45.04,,0,0.001,34.533,0.0593,0.017,0.0775,581.766,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-04",7,4.84,111.72,,0,0.001,77.22,0.0593,0.031,0.062,1298.59,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-05",4,2.27,42.64,,0,0.001,31.801,0.0593,0.014,0.0943,534.803,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-16",3,2.25,33.5,,0,0.001,28.205,0.0593,0.007,0.041,474.41,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-19",11,9.24,271.68,,0.001,0.001,172.972,0.0592,0.043,0.0412,2910.512,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-20",3,2.27,58.16,,0,0.001,39.217,0.059,0.015,0.036,660.62,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-21",4,2.33,64.3,,0,0.001,42.715,0.0593,0.016,0.036,719.395,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-24",4,2.5,42.75,,0,0.001,33.585,0.0595,0.013,0.07,564.685,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-25",8,6.63,116.56,,0,0.0009,91.303,0.0595,0.03,0.05,1535.159,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-26",8,6.67,118.98,,0,0.001,91.903,0.0595,0.026,0.0421,1544.795,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-27",4,2.65,42.45,,0,0.001,34.264,0.0598,0.013,0.0838,575.916,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-28",4,2.18,53.56,,0,0.001,36.514,0.0595,0.015,0.1095,614.263,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-05",8,7.62,319.94,,0.001,0.001,188.498,0.0593,0.034,0.0255,3170.872,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-06",1,0.78,14.04,,0,0.001,10.764,0.06,0.001,0.016,180.57,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-09",3,2.29,62.58,,0,0.001,40.706,0.059,0.011,0.031,685.905,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-12",7,4.86,137.63,,0,0.001,89.482,0.0591,0.028,0.0497,1506.613,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-21",3,2.25,41.35,,0,0.001,32.09,0.059,0.014,0.059,539.97,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-11",14,12.3,211.76,,0.001,0.001,165.966,0.0594,0.031,0.0318,2791.911,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-12",5,3.5,59.3,,0,0.001,46.38,0.0594,0.014,0.0532,781.715,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-13",7,5.28,81.53,,0,0.001,67.121,0.0591,0.017,0.0496,1131.533,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-18",14,12.48,221.3,,0.001,0.001,171.524,0.0594,0.031,0.0301,2885.324,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-20",7,5.27,94.2,,0,0.001,73.046,0.0594,0.019,0.0557,1228.628,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-21",2,1.08,43.4,,0,0.001,26.024,0.0595,0.013,0.147,437.356,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-22",10,5.53,90.56,,0,0.001,72.404,0.0591,0.023,0.0727,1220.124,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-01",9,6.61,116.99,,0,0.001,90.311,0.0597,0.023,0.044,1517.705,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-03",3,2.3,35.2,,0,0.001,29.098,0.0597,0.011,0.0387,489.002,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-04",5,3.27,52.87,,0,0.001,41.979,0.059,0.012,0.0604,708.565,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-05",5,3.85,65.2,,0,0.001,50.883,0.0594,0.013,0.0366,855.088,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-14",3,2.28,36.08,,0,0.001,29.068,0.0593,0.011,0.0407,490.168,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-16",3,2.25,43.86,,0,0.001,32.482,0.0593,0.012,0.0527,546.214,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-21",3,2.3,38.8,,0,0.001,30.16,0.0593,0.01,0.0553,506.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-26",4,2.23,32.8,,0,0.001,27.946,0.0598,0.011,0.0818,468.773,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-29",3,2.24,70.15,,0,0.001,44.927,0.0593,0.022,0.0677,755.789,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-30",6,4.5,70.1,,0,0.001,57.736,0.0593,0.019,0.0388,971.284,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-02",6,4.25,73.52,,0,0.001,56.818,0.0592,0.017,0.06,956.745,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-03",3,2,55.4,,0,0.001,36.58,0.0593,0.009,0.0377,615.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-04",4,2.28,36.4,,0,0.001,28.916,0.0598,0.009,0.0583,485.908,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-09",3,2.3,65.38,,0,0.001,42.356,0.0597,0.013,0.0477,711.886,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-10",4,2.75,72.2,,0,0.001,47.785,0.059,0.012,0.0428,805.385,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-16",4,2.29,33.97,,0,0.001,28.724,0.059,0.01,0.0328,484.51,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-19",2,0.52,13.63,,0,0.001,8.572,0.059,0.009,0.1005,144.388,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-20",21,18.76,305.1,,0.001,0.001,226.595,0.0593,0.038,0.0254,3811.695,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-05",4,2.27,62.52,,0,0.001,38.289,0.0595,0.012,0.0655,644.279,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-10",8,6.71,117.72,,0,0.0009,85.942,0.0595,0.017,0.0288,1444.87,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-11",6,4.56,70.72,,0,0.001,53.668,0.0598,0.013,0.0455,900.568,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-12",6,4.72,72.78,,0,0.001,55.194,0.059,0.013,0.0365,930.024,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-14",4,2.29,35.64,,0,0.001,26.694,0.059,0.01,0.0685,449.276,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-26",3,2.34,36.33,,0,0.001,27.799,0.0593,0.009,0.047,467.819,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-28",4,2.28,36.75,,0,0.001,27.155,0.0593,0.01,0.0783,456.61,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-29",4,2.63,55.53,,0,0.001,37.077,0.0595,0.011,0.0563,623.924,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-30",6,4.64,142.68,,0,0.001,83.928,0.0595,0.017,0.0442,1411.808,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-07-31",3,0.76,8.13,,0,0.001,7.327,0.0593,0.006,0.1583,123.469,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-01",5,3.17,61.5,,0,0.001,42.547,0.0592,0.011,0.0476,715.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-02",4,2.35,36.9,,0,0.001,28.06,0.0598,0.009,0.0555,471.145,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-09",3,2.26,39.92,,0,0.001,28.55,0.0593,0.01,0.0493,480.31,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-10",3,2.25,34.97,,0,0.001,26.257,0.059,0.009,0.0537,442.709,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-12",4,3,71.36,,0,0.001,45.508,0.0595,0.014,0.0468,765.566,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-13",6,4.44,85.84,,0,0.001,59.356,0.0593,0.018,0.0635,997.626,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-14",9,8.03,187.68,,0.001,0.001,121.01,0.0597,0.022,0.0252,2033.372,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-15",7,5.58,207.08,,0.001,0.001,117.18,0.059,0.022,0.0271,1974.166,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-16",7,5.43,205.4,,0.001,0.0009,116.146,0.0591,0.022,0.0313,1955.365,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-17",8,6.93,116.4,,0,0.0009,84.95,0.0594,0.014,0.0224,1428.478,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-18",10,8.93,228.4,,0.001,0.001,142.555,0.0591,0.024,0.0226,2401.176,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-19",7,5.93,124.4,,0,0.001,82.07,0.0597,0.013,0.0226,1379.23,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-20",5,3.66,57.45,,0,0.001,42.887,0.0598,0.01,0.0382,720.368,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-21",6,4.5,73.84,,0,0.001,54.72,0.0598,0.014,0.0525,919.906,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-22",7,5.97,112.5,,0,0.001,79.326,0.0593,0.016,0.0286,1335.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-23",3,1.99,32.49,,0,0.001,23.931,0.059,0.008,0.0337,403.06,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-24",7,5.7,128.61,,0,0.001,82.959,0.0591,0.019,0.0296,1396.63,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-25",2,0.4,3.8,,0,0.0005,3.614,0.06,0.004,0.087,60.886,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-27",4,2.63,64.28,,0,0.001,40.121,0.0593,0.01,0.0403,675.674,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-28",7,5.55,140.88,,0,0.001,87.804,0.0594,0.014,0.0247,1477.12,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-03",5,3.78,59.41,,0,0.001,45.387,0.059,0.011,0.0378,765.113,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-04",3,2.5,66.66,,0,0.001,41.264,0.0597,0.012,0.0297,693.686,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-05",9,7.94,180.4,,0.001,0.001,118.099,0.0593,0.022,0.0304,1987.356,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-06",13,11.22,248.4,,0.001,0.001,164.07,0.0593,0.03,0.0372,2762.046,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-07",4,2.26,34.76,,0,0.0008,26.223,0.0595,0.009,0.0605,441.399,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-09",10,9,264.19,,0.001,0.001,155.582,0.0593,0.031,0.0328,2617.145,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-10",4,2.25,33.76,,0,0.001,25.651,0.0593,0.01,0.065,432.14,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-11",7,4.57,102.34,,0,0.001,66.492,0.0594,0.023,0.0696,1117.613,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-15",7,5.79,116.48,,0,0.001,78.876,0.0593,0.021,0.0377,1327.785,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-16",3,2.27,69.78,,0,0.001,41.312,0.0597,0.018,0.0527,694.557,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-17",5,3.52,97,,0,0.001,59.904,0.0596,0.022,0.0704,1007.384,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-18",11,9.38,263.2,,0.001,0.001,160.85,0.0594,0.034,0.03,2708.319,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-19",5,3.05,79,,0,0.0008,49.475,0.0592,0.016,0.0604,833.325,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-21",7,5.52,94,,0,0.0009,68.072,0.0593,0.016,0.037,1147.14,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-22",4,2.25,57.76,,0,0.0008,36.089,0.0593,0.011,0.0793,606.962,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-23",3,2.33,42.96,,0,0.001,32.73,0.0593,0.012,0.0373,550.117,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-24",2,0.9,27.28,,0,0.001,17.418,0.059,0.009,0.065,293.716,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-28",4,2.39,43.48,,0,0.001,33.46,0.0593,0.009,0.062,562.999,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-29",3,2.39,39.85,,0,0.001,31.589,0.0597,0.01,0.0453,530.924,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-09-30",5,3.33,53.6,,0,0.001,42.931,0.0594,0.012,0.0646,722.646,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-01",4,2.36,35.63,,0,0.001,29.157,0.059,0.011,0.076,490.581,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-02",6,4.79,77.8,,0,0.001,61.457,0.0595,0.015,0.0345,1033.639,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-03",4,2.24,35.64,,0,0.0008,28.948,0.0598,0.01,0.0695,486.01,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-04",4,2.76,43.95,,0,0.001,35.53,0.059,0.011,0.0458,598.541,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-05",5,4.02,106,,0,0.0008,69.642,0.059,0.019,0.0396,1172.81,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-12",7,6.2,142.4,,0.001,0.001,99.08,0.059,0.03,0.0924,1669.34,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-13",4,2.47,39.9,,0,0.001,32.274,0.0593,0.012,0.0743,544.07,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-14",4,3.53,91.48,,0,0.001,62.231,0.0595,0.015,0.043,1046.473,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-15",8,5.37,104.62,,0,0.0009,78.508,0.0594,0.022,0.045,1319.958,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-16",4,2.45,36.6,,0,0.001,30.95,0.0593,0.011,0.083,520.86,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-19",4,2.3,37.5,,0,0.001,30.3,0.0593,0.012,0.0723,509.765,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-22",7,4.57,99.19,,0,0.001,71.415,0.0596,0.023,0.0746,1200.628,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-28",3,2.28,34.1,,0,0.001,28.642,0.0593,0.011,0.049,482.184,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-01",6,3.17,45.47,,0,0.0008,38.883,0.0592,0.026,0.0972,653.21,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-03",12,6.83,139.43,,0.001,0.0008,103.665,0.0592,0.034,0.0531,1744.553,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-04",7,5.74,110.8,,0,0.0009,83.604,0.0596,0.019,0.0263,1405.274,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-05",11,8.87,182.28,,0.001,0.001,133.349,0.0592,0.03,0.0435,2242.307,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-06",4,2.26,34.53,,0,0.001,28.501,0.0593,0.011,0.0698,479.932,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-09",4,2.25,33.99,,0,0.001,27.561,0.0588,0.012,0.064,464.229,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-10",3,2.24,34.28,,0,0.001,28.248,0.0597,0.014,0.062,474.604,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-11",7,4.72,71.13,,0,0.001,58.208,0.0594,0.025,0.0773,979.548,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-16",3,2.29,35.06,,0,0.001,28.984,0.059,0.011,0.056,488.214,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-17",3,2.22,34.66,,0,0.001,28.822,0.0593,0.013,0.0537,485.046,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-18",3,2.25,38.25,,0,0.001,30.275,0.059,0.012,0.0503,509.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-21",4,2.63,39.59,,0,0.001,33.271,0.0595,0.013,0.0633,559.239,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-29",4,2.38,35.7,,0,0.001,30.066,0.059,0.013,0.0813,507.256,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-01",11,8.28,238.23,,0.001,0.001,151.97,0.0593,0.045,0.054,2557.235,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-11",3,2.27,33.78,,0,0.001,28.467,0.0593,0.011,0.056,479.261,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-15",3,2.22,33.3,,0,0.001,27.6,0.059,0.012,0.0537,465.21,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-16",4,2.47,36.83,,0,0.001,30.553,0.0598,0.012,0.0813,513.954,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-18",4,2.84,50.32,,0,0.001,38.409,0.0593,0.013,0.056,646.387,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-19",7,5.04,79.64,,0,0.001,66.729,0.0591,0.024,0.064,1122.862,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-20",11,6.98,119.35,,0,0.001,95.899,0.0592,0.038,0.0848,1614.297,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-21",3,2.32,33.84,,0,0.001,29.216,0.0597,0.012,0.08,490.808,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-29",4,2.32,42.05,,0,0.0008,32.174,0.0598,0.011,0.0678,540.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-01",21,20.05,376,,0.001,0.001,263.91,0.0594,0.031,0.0168,4441.08,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-06",5,3.25,55.16,,0,0.001,40.601,0.059,0.013,0.069,683.645,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-07",5,3.24,54.87,,0,0.001,40.264,0.0594,0.011,0.0616,677.744,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-08",7,4.39,75.78,,0,0.001,54.406,0.0594,0.017,0.0624,915.441,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-09",17,11.92,207.28,,0.001,0.001,149.005,0.0595,0.028,0.0445,2505.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-10",24,22.22,412.04,,0.001,0.001,289.409,0.0595,0.042,0.0233,4868.262,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-11",1,0.07,0,,0,0.001,0.42,0.06,0,0.066,7.042,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-13",4,2.2,36.8,,0,0.001,26.868,0.059,0.012,0.0823,453.588,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-24",4,2.22,46.65,,0,0.001,31.716,0.0593,0.009,0.066,533.081,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-30",3,2.26,46.01,,0,0.001,31.572,0.0593,0.012,0.0497,530.904,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-16",2,0.85,14.4,,0,0.001,10.56,0.0595,0.007,0.0805,177.535,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-20",3,2.03,57.2,,0,0.001,35.385,0.059,0.009,0.0517,596.579,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-24",4,2.5,45.65,,0,0.001,32.885,0.0595,0.008,0.0423,552.505,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-25",8,6.48,118.89,,0,0.0009,85.676,0.0595,0.018,0.0418,1441.462,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-26",8,6.65,131.6,,0,0.001,91.455,0.0594,0.018,0.0333,1538.505,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-27",4,2.65,46.51,,0,0.001,34.321,0.0593,0.012,0.0635,576.928,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-28",3,2.17,52.52,,0,0.001,33.985,0.0593,0.011,0.036,571.991,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-12",3,2.33,41.87,,0,0.001,29.816,0.0593,0.013,0.053,501.813,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-21",3,2.27,45.17,,0,0.001,31.632,0.0597,0.014,0.0557,531.74,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-01",4,2.59,48.76,,0,0.001,34.248,0.0593,0.011,0.0493,575.51,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-10",8,6.57,122.96,,0,0.001,85.305,0.0591,0.016,0.0348,1437.356,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-21",2,1.08,44.4,,0,0.001,24.384,0.059,0.014,0.124,411.016,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-22",6,3.2,63.7,,0,0.0008,44.885,0.0593,0.014,0.0817,755.135,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-01",3,2.29,46.04,,0,0.001,31.86,0.059,0.016,0.0643,536.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-05",6,4.46,80.6,,0,0.001,58.149,0.0593,0.015,0.0448,978.368,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-16",4,2.52,52.1,,0,0.001,35.889,0.0598,0.013,0.0555,602.555,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-21",3,2.28,41.28,,0,0.001,29.832,0.0597,0.012,0.062,501.296,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-29",3,2.25,72.93,,0,0.001,43.057,0.059,0.036,0.171,724.928,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-30",6,4.5,77.85,,0,0.001,57.629,0.0597,0.017,0.0353,968.271,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-02",6,4.26,81.95,,0,0.001,57.697,0.0595,0.014,0.046,969.946,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-03",3,2.37,64.24,,0,0.001,40.453,0.0597,0.016,0.054,679.764,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-04",4,2.28,39.6,,0,0.001,29.02,0.059,0.01,0.0663,489.424,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-08",4,2.35,44.04,,0,0.001,31.693,0.059,0.007,0.041,534.01,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-09",3,2.25,68.3,,0,0.001,41.145,0.0593,0.011,0.0403,692.764,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-10",4,2.77,74.72,,0,0.001,46.888,0.0595,0.012,0.0505,788.017,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-16",4,2.3,38.08,,0,0.001,28.67,0.0595,0.01,0.0288,481.856,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-20",2,0.57,14.86,,0,0.001,9.495,0.059,0.008,0.105,160.065,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-03",3,2.32,59.92,,0,0.001,37.928,0.0593,0.007,0.0213,638.588,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-05",4,2.29,65.74,,0,0.001,40.906,0.0593,0.014,0.0583,689.162,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-07",4,2.37,43.62,,0,0.001,31.646,0.0595,0.011,0.06,532.451,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-10",8,6.73,131.08,,0,0.001,93.143,0.0591,0.018,0.0294,1569.281,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-26",3,2.35,40.6,,0,0.001,30.248,0.0597,0.009,0.0443,507.614,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-29",4,2.38,56.2,,0,0.001,37.16,0.0593,0.011,0.0573,625.416,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-30",1,0.03,0,,0,0,0.144,0.06,0,0.072,2.406,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-07-31",3,1.23,15.78,,0,0.001,13.389,0.059,0.012,0.1003,225.748,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-09",3,2.28,44.76,,0,0.001,31.32,0.059,0.006,0.0257,527.432,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-13",5,3.48,73.05,,0,0.001,50.231,0.06,0.018,0.0502,842.725,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-14",9,8.04,209.46,,0.001,0.001,133.289,0.0592,0.023,0.0263,2243.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-15",7,5.59,218.6,,0.001,0.001,124.656,0.0594,0.022,0.0314,2096.482,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-16",9,7.45,287.8,,0.001,0.001,164.655,0.0591,0.03,0.0301,2773.095,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-17",7,5.77,106.11,,0,0.001,76.198,0.0594,0.014,0.0314,1281.595,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-18",6,5.42,136.66,,0,0.001,88.28,0.059,0.017,0.0237,1487.75,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-19",6,4.03,71.21,,0,0.001,51.579,0.0595,0.012,0.0712,868.097,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-22",1,0.43,4.73,,0,0.001,4.3,0.06,0.01,0.287,72.24,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-23",4,2.33,42.5,,0,0.001,30.593,0.0598,0.007,0.034,513.94,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-24",9,6.57,180.3,,0.001,0.0009,112.056,0.0593,0.027,0.0539,1885.449,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-25",5,2.84,52.04,,0,0.0006,37.426,0.0594,0.008,0.0616,630.666,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-26",5,3.43,60.9,,0,0.001,44.61,0.0598,0.008,0.035,749.446,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-27",5,3.4,87.95,,0,0.001,54.984,0.0596,0.012,0.0426,925.257,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-28",7,5.37,142.4,,0,0.001,89.664,0.0593,0.017,0.0351,1508.429,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-03",4,3.1,59.07,,0,0.001,42.501,0.0593,0.018,0.0488,714.895,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-04",5,4.01,105.56,,0,0.001,66.979,0.0596,0.014,0.0324,1126.102,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-05",8,7.31,201.31,,0.001,0.001,126.172,0.0593,0.021,0.021,2121.66,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-06",10,8.6,207.97,,0.001,0.001,136.148,0.0593,0.023,0.0293,2289.978,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-07",5,3.3,58.25,,0,0.001,42.475,0.0594,0.011,0.0446,714.555,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-08",4,2.25,38.64,,0,0.0008,28.523,0.0595,0.009,0.0523,479.333,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-09",4,2.25,36.76,,0,0.001,27.741,0.059,0.01,0.071,468.077,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-10",16,11.42,305.49,,0.001,0.001,188.635,0.0594,0.035,0.0656,3174.928,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-11",7,4.66,111.82,,0,0.001,71.924,0.0593,0.02,0.0489,1211.214,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-14",3,2.28,50.98,,0,0.001,33.894,0.0593,0.012,0.048,571.228,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-15",1,0.65,24.05,,0,0.001,13.78,0.06,0.01,0.083,231.335,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-16",3,2.32,75.32,,0,0.001,44.876,0.0593,0.015,0.04,754.384,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-17",5,3.53,104,,0,0.001,60.427,0.0594,0.014,0.0472,1016.22,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-18",11,9.02,330.45,,0.001,0.001,180.754,0.0593,0.028,0.0191,3041.249,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-19",5,3.06,86,,0,0.0008,50.297,0.0598,0.011,0.0364,844.377,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-21",6,4.6,82.32,,0,0.001,56.821,0.0593,0.015,0.0345,955.749,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-22",4,2.26,61.99,,0,0.001,36.443,0.059,0.009,0.0523,613.599,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-23",3,2.35,45.55,,0,0.001,34.4,0.059,0.012,0.0357,579.83,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-28",4,2.4,47.8,,0,0.001,35.9,0.0595,0.01,0.0488,602.972,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-29",4,2.43,43.95,,0,0.001,34.252,0.0595,0.009,0.0535,575.643,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-09-30",5,3.35,60.2,,0,0.001,46.805,0.0592,0.011,0.051,787.69,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-01",3,2.18,35.48,,0,0.001,28.759,0.0593,0.009,0.038,483.941,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-02",6,4.8,87.24,,0,0.001,66.872,0.0593,0.013,0.0295,1125.24,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-03",4,2.27,38.86,,0,0.0008,31.119,0.0595,0.01,0.0588,523.612,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-04",4,2.78,49.41,,0,0.001,38.44,0.0595,0.01,0.0435,647.005,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-05",3,2.83,111.05,,0,0.001,66.228,0.059,0.017,0.0297,1114.073,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-06",4,2.27,38.86,,0,0.001,30.835,0.0595,0.01,0.061,518.422,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-12",6,4.54,120.02,,0,0.001,81.858,0.0592,0.019,0.0375,1376.838,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-13",4,2.53,46.61,,0,0.001,36.07,0.0595,0.012,0.057,607.043,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-14",5,3.57,92.35,,0,0.001,63.097,0.0592,0.011,0.0338,1062.513,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-15",8,5.42,117.04,,0,0.001,85.498,0.0594,0.022,0.0435,1439.342,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-16",4,2.47,43,,0,0.001,34.054,0.0593,0.009,0.0523,574.103,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-19",4,2.34,41.44,,0,0.0008,33.094,0.0593,0.012,0.0595,557.124,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-22",7,4.84,112.32,,0,0.001,80.265,0.0593,0.023,0.0476,1350.361,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-26",3,2.3,37.66,,0,0.001,30.463,0.0597,0.012,0.0503,511.466,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-01",1,0.52,8.84,,0,0.001,6.812,0.059,0.007,0.115,114.608,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-02",7,4.43,80.4,,0,0.001,63.311,0.0593,0.017,0.0589,1066.185,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-03",8,4.58,103.9,,0,0.0009,75.94,0.0594,0.021,0.0338,1277.277,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-04",7,5.74,118.92,,0,0.001,89.45,0.059,0.018,0.0269,1506.62,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-05",11,8.99,196.47,,0.001,0.001,142.598,0.0595,0.027,0.0334,2399.304,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-06",4,2.28,37.99,,0,0.001,30.52,0.0598,0.011,0.059,512.302,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-07",4,2.35,49.22,,0,0.001,36.135,0.0595,0.012,0.066,607.463,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-08",4,2.52,44,,0,0.0008,34.476,0.0595,0.012,0.0573,579.512,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-09",6,4.68,78.13,,0,0.001,62.012,0.0595,0.021,0.0488,1041.864,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-10",3,2.25,37.57,,0,0.001,29.569,0.059,0.011,0.0423,498.397,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-11",4,2.31,38.36,,0,0.001,30.354,0.059,0.011,0.0535,511.34,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-13",4,2.45,42.88,,0,0.001,34.235,0.0595,0.01,0.0623,576.005,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-15",4,2.43,53.3,,0,0.001,37.613,0.0595,0.013,0.0708,633.44,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-21",4,2.44,40.8,,0,0.001,33.028,0.059,0.011,0.0623,556.98,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-01",8,6.25,194.86,,0.001,0.001,123.613,0.0595,0.033,0.042,2079.882,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-11",3,2.28,37.2,,0,0.001,30.74,0.059,0.014,0.0583,518.082,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-16",3,2.13,34.76,,0,0.001,27.923,0.0593,0.011,0.0463,471.005,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-18",4,2.43,43.56,,0,0.001,34.744,0.0595,0.014,0.0748,585.619,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-19",4,2.41,41.2,,0,0.001,32.332,0.0595,0.012,0.0865,543.412,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-20",4,2.36,47.82,,0,0.001,36.365,0.0598,0.013,0.0718,610.89,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-21",4,2.45,45.8,,0,0.001,35.452,0.0595,0.011,0.07,597.049,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-25",4,2.27,40.75,,0,0.001,32.003,0.059,0.014,0.0343,540.12,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-28",3,2.65,50.82,,0,0.001,39.043,0.0593,0.015,0.048,656.264,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-29",4,2.4,46.1,,0,0.001,35.39,0.059,0.014,0.0748,595.68,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-01",21,20.05,459.3,,0.001,0.0001,275.605,0.0594,0.013,0.0054,4636.47,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-06",19,18.17,1075.72,,0.003,0.0009,505.123,0.0592,0.026,0.0075,8501.868,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-07",24,24,1505,,0.004,0.0009,692,0.0592,0.033,0.0056,11641.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-08",24,24,1495,,0.004,0.001,685.4,0.0593,0.032,0.0056,11531.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-09",24,24,1490,,0.004,0.001,681,0.0592,0.031,0.0053,11459.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-10",24,24,1443,,0.003,0.001,662.6,0.0591,0.031,0.0055,11152.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-11",24,23.93,1286.66,,0.003,0.001,601.419,0.0592,0.028,0.0055,10120.066,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-12",24,23.98,1290.62,,0.003,0.0009,602.176,0.0593,0.027,0.0054,10128.416,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-13",16,13.38,661.76,,0.002,0.0009,320.794,0.0593,0.017,0.0089,5399.744,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-03",5,4.23,87.45,,0,0.0002,59.006,0.0594,0.005,0.0166,992.873,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-04",12,8.73,283.18,,0.001,0.0007,157.54,0.0594,0.012,0.009,2651.251,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-20",10,8.36,287.98,,0.001,0.0008,161.798,0.0593,0.009,0.0109,2723.172,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-24",6,4.5,99.3,,0,0.0003,65.475,0.0593,0.005,0.0132,1103.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-25",8,6.38,138.19,,0,0.0003,89.059,0.0595,0.006,0.011,1496.977,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-26",5,4.23,106.49,,0,0.0004,67.38,0.0592,0.007,0.0124,1133.393,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-28",6,4.16,99.71,,0,0.0005,63.53,0.0593,0.005,0.0113,1068.542,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-02",5,4.21,98.24,,0,0.0006,62.988,0.0592,0.006,0.0126,1060.125,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-05",8,7.63,328.46,,0.001,0.001,169.976,0.0593,0.012,0.009,2859.583,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-06",5,4.85,273.35,,0.001,0.0008,127.77,0.0592,0.007,0.0062,2150.09,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-12",1,0.5,7,,0,0,6.2,0.06,0.006,0.108,104,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-13",11,8.51,270.83,,0.001,0.0005,158.101,0.0592,0.009,0.0085,2659.693,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-14",6,4.3,96.2,,0,0.0003,62.859,0.0592,0.011,0.0195,1057.55,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-09",4,0.61,5.2,,0,0.0005,5.695,0.0588,0.007,0.0715,95.675,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-10",10,8.15,301.17,,0.001,0.0008,158.082,0.0595,0.008,0.0142,2658.668,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-11",14,12.25,285.2,,0.001,0.0004,172.675,0.0596,0.013,0.0101,2903.13,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-12",13,10.03,223.93,,0.001,0.0002,140.379,0.0594,0.018,0.0115,2361.408,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-13",7,5.3,187.22,,0.001,0.0009,101.919,0.0594,0.005,0.0066,1714.072,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-18",14,12.5,335.2,,0.001,0.0002,193.256,0.0594,0.016,0.0124,3251.28,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-20",7,5.3,179.7,,0.001,0.0009,99.37,0.0593,0.006,0.0129,1671.86,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-22",5,4.27,105.38,,0,0.0006,64.363,0.0598,0.006,0.0114,1082.093,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-25",1,0.17,0.34,,0,0.001,1.003,0.059,0.001,0.069,17,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-28",12,10.35,535.92,,0.001,0.0004,257.879,0.0591,0.014,0.0068,4340.485,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-29",5,3.85,77.97,,0,0.0002,54.01,0.059,0.005,0.0184,909.589,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-05",5,4.3,92.15,,0,0.0004,61.87,0.0592,0.014,0.0258,1040.83,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-06",5,4.3,89.86,,0,0.0004,59.88,0.0592,0.005,0.011,1007.222,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-09",5,4.32,103.4,,0,0.0008,70.122,0.0592,0.017,0.031,1179.942,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-11",3,1.48,55.58,,0,0.001,34.228,0.059,0.02,0.0553,575.968,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-12",2,1.07,18.69,,0,0,14.773,0.06,0.009,0.077,248.202,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-20",2,1.35,26.95,,0,0.0005,20.35,0.059,0.005,0.05,342.785,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-21",4,3.07,64.42,,0,0.0003,40.906,0.0598,0.002,0.0038,687.376,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-26",5,4.22,109.6,,0,0.0004,68.612,0.0592,0.009,0.015,1155.162,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-27",5,4.27,93.25,,0,0.0004,61.696,0.0594,0.008,0.0198,1038.308,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-29",6,4.29,136.58,,0,0.0007,81.68,0.0593,0.011,0.0152,1374.33,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-30",5,4.32,96.36,,0,0.0006,61.708,0.0592,0.008,0.0152,1039.388,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-02",5,4.18,100.34,,0,0.0006,63.926,0.0592,0.008,0.0176,1075.408,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-03",6,4.35,130.62,,0,0.0007,76.893,0.0592,0.008,0.0188,1294.59,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-09",6,4.45,127.87,,0,0.0007,77.038,0.0593,0.01,0.0153,1297.156,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-10",2,1.27,45.15,,0,0.001,28.313,0.059,0.007,0.0485,476.61,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-11",2,0.34,3.52,,0,0.0005,3.492,0.0565,0.003,0.0585,58.922,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-20",21,19.3,716.41,,0.002,0.0006,366.53,0.0593,0.017,0.0057,6169.252,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-24",11,9.58,357.17,,0.001,0.0007,185.22,0.0595,0.014,0.0123,3115.793,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-06",5,4.32,119.36,,0,0.0006,71.412,0.0592,0.009,0.0202,1202.276,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-07",6,4.35,103.97,,0,0.0003,66.095,0.0593,0.009,0.0182,1111.578,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-09",5,4.32,91.56,,0,0.0002,60.516,0.0594,0.008,0.0212,1018.416,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-10",7,5.18,159.1,,0,0.0007,96.666,0.0591,0.009,0.0116,1627.171,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-11",5,4.56,147.36,,0,0.0008,82.672,0.0592,0.009,0.0182,1391.606,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-12",6,4.87,128.02,,0,0.0005,78.23,0.0597,0.01,0.012,1314.314,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-13",6,4.31,91.88,,0,0.0003,60.781,0.0595,0.008,0.0183,1022.135,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-26",5,4.25,91.75,,0,0.0002,62.069,0.0594,0.008,0.0214,1044.481,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-28",5,4.25,97,,0,0.0002,62.275,0.0592,0.009,0.0204,1048.55,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-29",6,4.39,133.31,,0,0.0005,76.156,0.0593,0.008,0.0192,1282.336,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-30",9,7.59,260.44,,0.001,0.0008,138.871,0.0592,0.012,0.0158,2336.061,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-07-31",8,6.87,201.18,,0.001,0.0006,113.966,0.0594,0.01,0.0158,1917.012,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-01",5,4.23,114.71,,0,0.0006,68.772,0.0594,0.008,0.0204,1157.106,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-02",6,4.44,94.64,,0,0.0002,61.716,0.059,0.008,0.0188,1039.818,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-03",6,4.95,106.57,,0,0.0003,69.408,0.0592,0.008,0.0118,1168.525,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-09",5,4.41,91.62,,0,0.0004,62.793,0.0592,0.008,0.0158,1056.496,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-10",6,4.37,91.01,,0,0.0003,61.916,0.0597,0.009,0.0205,1040.921,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-12",6,4.25,95.52,,0,0.0005,62.796,0.059,0.009,0.0113,1057.117,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-13",8,6.87,186.44,,0.001,0.0005,109.344,0.0594,0.01,0.0163,1839.92,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-14",9,8.04,373.12,,0.001,0.0009,184.275,0.0591,0.015,0.015,3103.456,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-15",11,9.85,472.3,,0.001,0.0008,233.715,0.0593,0.017,0.0144,3931.64,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-16",9,8.01,444.88,,0.001,0.0009,212.566,0.059,0.016,0.0151,3579.809,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-17",12,11.28,357.1,,0.001,0.0006,194.916,0.0592,0.015,0.0124,3282.447,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-18",13,11.7,376.02,,0.001,0.0006,204.538,0.0592,0.015,0.012,3443.082,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-19",11,9.7,388.55,,0.001,0.0008,196.13,0.0593,0.015,0.0134,3301.285,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-20",12,11.17,398.37,,0.001,0.0006,207.966,0.0592,0.017,0.0136,3500.455,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-21",7,5.9,195.44,,0.001,0.0004,112.884,0.0593,0.013,0.014,1897.984,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-22",13,12.1,381.7,,0.001,0.0004,211.495,0.0592,0.015,0.0105,3562.49,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-23",5,4.3,95.6,,0,0.0002,62.305,0.0594,0.009,0.0246,1048.64,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-24",7,6.28,207.87,,0.001,0.0009,115.272,0.0593,0.011,0.0181,1940.869,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-25",7,6.3,142.2,,0,0.0001,90.165,0.0593,0.009,0.0167,1517.315,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-26",5,4.42,97.92,,0,0.0002,62.858,0.0598,0.007,0.0218,1055.817,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-27",7,6.35,216.45,,0.001,0.0006,118.335,0.0593,0.012,0.0111,1991.225,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-28",6,4.34,169.15,,0,0.0007,91.321,0.059,0.01,0.0208,1538.142,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-03",3,0.32,2,,0,0.0003,2.357,0.0727,0.001,0.0237,39.755,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-04",5,4.25,147,,0,0.0008,81.865,0.0596,0.004,0.0058,1375.885,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-05",11,9.59,353.94,,0.001,0.0007,188.724,0.0594,0.015,0.013,3174.526,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-06",10,9.58,385.04,,0.001,0.001,197.893,0.0592,0.015,0.0102,3332.503,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-07",5,4.28,90.61,,0,0.0002,60.221,0.0596,0.008,0.0228,1011.917,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-08",5,4.23,86.7,,0,0.0002,58.052,0.0592,0.008,0.022,977.174,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-11",11,8.89,228.63,,0.001,0.0006,143.484,0.0595,0.014,0.0138,2411.992,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-15",6,5.46,139.48,,0,0.0005,86.742,0.0593,0.01,0.019,1459.67,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-16",5,4.6,162.64,,0,0.0006,89.024,0.0592,0.012,0.0136,1498.736,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-17",5,4.43,140.45,,0,0.0006,85.071,0.0594,0.012,0.024,1431.637,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-18",11,9.82,410.58,,0.001,0.0008,209.648,0.0593,0.014,0.0096,3527.78,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-19",8,6.57,189.13,,0,0.0006,107.87,0.0593,0.011,0.016,1815.499,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-21",5,4.35,95.47,,0,0.0004,61.739,0.059,0.008,0.0154,1040.834,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-22",6,4.4,120.68,,0,0.0007,74.548,0.0592,0.009,0.013,1253.712,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-28",6,4.41,113.21,,0,0.0007,73.576,0.0593,0.01,0.0198,1237.272,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-29",7,5.32,120.84,,0,0.0003,77.064,0.059,0.008,0.0157,1298.072,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-09-30",10,9.33,327.88,,0.001,0.0004,173.373,0.0592,0.009,0.0069,2917.068,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-01",6,4.47,95.46,,0,0.0003,62.418,0.0595,0.008,0.0202,1049.663,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-02",6,4.7,100.34,,0,0.0003,65.17,0.0593,0.008,0.0155,1096.88,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-03",6,4.26,91.77,,0,0.0003,60.071,0.0592,0.003,0.0063,1011.006,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-04",5,4.19,102.89,,0,0.0004,65.552,0.0594,0.008,0.0118,1102.473,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-05",6,4.3,162.05,,0.001,0.0008,95.89,0.0595,0.005,0.0077,1611.57,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-06",6,4.23,93.82,,0,0.0005,59.588,0.0595,0.007,0.0155,1002.012,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-12",7,5.24,145.42,,0,0.0006,88.986,0.0593,0.005,0.009,1497.676,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-13",5,4.32,98.58,,0,0.0004,63.136,0.0594,0.008,0.0154,1063.032,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-14",6,4.28,148.83,,0,0.0007,81.68,0.0592,0.008,0.0157,1376.15,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-15",9,8.74,302.42,,0.001,0.0008,164.012,0.0593,0.009,0.0064,2758.562,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-16",5,4.35,92.87,,0,0.0006,61.28,0.0596,0.008,0.0146,1030.474,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-17",6,4.25,90.45,,0,0.0005,59.791,0.059,0.007,0.0142,1006.572,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-19",10,8.66,192.03,,0.001,0.0002,125.006,0.0595,0.01,0.0125,2102.66,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-22",7,6.33,200.86,,0.001,0.0007,112.906,0.0591,0.013,0.017,1900.665,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-02",12,11.05,579.31,,0.002,0.001,284.786,0.0592,0.035,0.014,4792.855,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-03",11,8.6,213.28,,0.001,0.0006,134.736,0.0592,0.02,0.0164,2269.104,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-04",8,6.38,159.44,,0,0.0005,100.182,0.0595,0.012,0.0166,1684.024,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-05",11,9.15,366.66,,0.001,0.0008,191.131,0.0595,0.01,0.0069,3215.745,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-06",5,4.29,87.94,,0,0.0002,59.495,0.059,0.004,0.009,1002.536,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-07",5,4.33,91.61,,0,0.0004,59.629,0.0594,0.004,0.008,1002.601,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-09",6,4.25,91.39,,0,0.0005,58.653,0.0595,0.003,0.0068,985.261,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-10",5,4.32,89.08,,0,0.0002,58.524,0.0592,0.004,0.009,985.992,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-21",6,4.38,89.36,,0,0.0003,61.12,0.0597,0.005,0.01,1027.964,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-29",6,4.35,89.12,,0,0.0005,60.717,0.0595,0.006,0.0097,1020.284,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-01",11,8.83,275.69,,0.001,0.0006,173.487,0.0592,0.018,0.0206,2919.877,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-02",6,4.42,93.82,,0,0.0005,62.724,0.0597,0.006,0.014,1053.578,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-20",1,0.07,0,,0,0,0.168,0.06,0,0.034,2.821,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Glenarm",422,"GT5",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"01",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Low NOx Burner Technology (Dry Bottom only),Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Olive",6013,"02",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Dry bottom wall-fired boiler",,"Combustion Modification/Fuel Reburning,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-14",18,17.12,561,,0.001,0.001,290.796,0.0591,0.043,0.0361,4895.596,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-15",23,22.17,811.17,,0.002,0.001,408.961,0.0591,0.029,0.0093,6881.386,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-01",4,3.63,124.56,,0,0.001,64.285,0.0595,0.022,0.0815,1080.778,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-02",24,24,984,,0.002,0.001,482.2,0.0593,0.033,0.0082,8116.3,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-03",24,24,976,,0.002,0.001,479.9,0.0592,0.033,0.0082,8074.4,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-04",24,24,1019,,0.003,0.001,496.5,0.059,0.034,0.0081,8358,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-05",24,24,950,,0.002,0.001,469.8,0.0593,0.032,0.0082,7904.9,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-06",24,24,861,,0.002,0.001,434.9,0.0591,0.03,0.0083,7318.1,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-07",24,24,863,,0.002,0.001,435.6,0.0592,0.03,0.0083,7330.1,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-08",24,24,968,,0.002,0.001,476.9,0.0592,0.033,0.0083,8025.6,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-09",24,24,1002,,0.002,0.001,489,0.0593,0.034,0.0082,8225.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-10",24,24,979,,0.002,0.001,481.1,0.0593,0.033,0.0083,8098.5,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-11",24,24,983,,0.002,0.001,483.5,0.0593,0.033,0.0082,8137,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-12",24,24,917,,0.002,0.001,457.7,0.0591,0.031,0.0082,7702.3,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-13",24,24,919,,0.002,0.001,458.2,0.0593,0.032,0.0083,7709.2,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-14",24,24,879,,0.002,0.001,441.6,0.0593,0.03,0.0082,7430.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-15",24,24,899,,0.002,0.001,450,0.0595,0.031,0.0083,7569.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-16",24,24,899,,0.002,0.001,449.9,0.0593,0.031,0.0081,7574.7,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-17",24,24,918,,0.002,0.001,457.2,0.0592,0.031,0.0081,7697.7,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-18",24,24,985,,0.002,0.001,482.7,0.0595,0.033,0.0081,8117.3,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-19",19,18.7,711.5,,0.002,0.001,355.74,0.0592,0.027,0.01,5989.93,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-24",17,16.15,647.15,,0.002,0.001,321.2,0.0592,0.045,0.0351,5403.81,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-25",24,24,902,,0.002,0.001,453.5,0.0593,0.031,0.0083,7627.9,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-26",24,24,837,,0.002,0.001,429,0.0592,0.029,0.0081,7219,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-27",24,24,931,,0.002,0.001,465.3,0.0592,0.032,0.0081,7830.1,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-28",24,24,974,,0.002,0.001,482,0.0593,0.033,0.0081,8108.4,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-02-29",24,24,871,,0.002,0.001,440.6,0.0593,0.03,0.0081,7414.7,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-01",24,24,964,,0.002,0.001,475.5,0.0594,0.032,0.0081,8001.3,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-02",24,24,933,,0.002,0.001,463.7,0.0594,0.032,0.0081,7799.7,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-03",24,24,888,,0.002,0.001,446.5,0.0592,0.031,0.0082,7516.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-04",13,12.03,410,,0.001,0.001,210.857,0.0591,0.017,0.0091,3549.975,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-05",1,0.08,0,,0,0.001,0.168,0.06,0,0.304,2.784,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-20",2,1.18,10.31,,0,0.001,9.167,0.06,0.021,0.318,153.842,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-01",12,10.82,345.02,,0.001,0.001,180.58,0.0592,0.025,0.0328,3040.022,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-04",8,7.13,280.13,,0.001,0.001,139.629,0.0598,0.029,0.0538,2345.941,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-05",24,24,966,,0.002,0.001,477.4,0.0594,0.033,0.0082,8029.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-06",24,24,947,,0.002,0.001,470.9,0.0591,0.033,0.0083,7927.5,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-07",24,24,770,,0.002,0.001,402.1,0.0591,0.028,0.0083,6766.2,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-08",13,12.03,341,,0.001,0.001,184.257,0.0591,0.015,0.009,3099.475,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-27",13,12.2,426.2,,0.001,0.001,219.34,0.0593,0.031,0.0303,3690.98,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-28",21,20.52,680.68,,0.002,0.001,355.36,0.0596,0.025,0.0086,5973.556,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-04",11,8.7,250.57,,0.001,0.001,135.54,0.0593,0.029,0.08,2279.141,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-05",2,1.32,32.56,,0,0.001,18.372,0.06,0.002,0.0285,308.448,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-24",12,11.28,389.4,,0.001,0.001,200.052,0.0595,0.029,0.0313,3365.288,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-25",24,24,824,,0.002,0.001,424.1,0.0597,0.029,0.008,7128.2,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-26",24,24,816,,0.002,0.001,420.5,0.0596,0.028,0.008,7070.5,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-27",21,20.82,744.12,,0.002,0.001,377.046,0.0599,0.028,0.0093,6333.434,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-30",12,10.46,373.04,,0.001,0.001,188.982,0.0593,0.032,0.0402,3182.002,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-10",3,2.23,55.23,,0,0.001,30.651,0.0593,0.027,0.1333,515.683,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-11",24,24,875,,0.002,0.001,438,0.0593,0.029,0.0079,7368.2,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-12",24,24,873,,0.002,0.001,438,0.0592,0.03,0.0081,7370.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-13",24,24,907,,0.002,0.001,451.2,0.0594,0.031,0.0082,7587.1,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-14",24,24,749,,0.002,0.001,391.9,0.0598,0.027,0.0081,6582.9,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-15",24,24,953,,0.002,0.001,468.6,0.0597,0.032,0.008,7878.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-16",24,24,987,,0.002,0.001,482.2,0.0595,0.032,0.008,8108.7,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-17",24,24,923,,0.002,0.001,458.1,0.0595,0.031,0.008,7703.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-18",24,24,950,,0.002,0.001,469.6,0.0592,0.032,0.008,7898.3,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-19",24,24,909,,0.002,0.001,453.7,0.0594,0.031,0.008,7630.6,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-20",24,24,769,,0.002,0.001,401,0.0597,0.027,0.008,6737.6,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-21",24,24,869,,0.002,0.001,439.6,0.0595,0.03,0.008,7391,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-22",23,23,794,,0.002,0.001,406.9,0.0592,0.029,0.0086,6848.2,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-23",1,0.08,0,,0,0.001,0.152,0.059,0,0.324,2.576,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-05",14,13.25,512.25,,0.001,0.001,253.575,0.0595,0.033,0.0299,4264.35,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-06",24,24,896,,0.002,0.001,448.7,0.0595,0.03,0.008,7543.5,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-07",24,24,863,,0.002,0.001,434,0.0595,0.031,0.0086,7295.1,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-08",13,12.8,391.4,,0.001,0.001,206.04,0.0596,0.032,0.0255,3463.94,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-10",4,3.48,110.28,,0,0.001,57.872,0.059,0.021,0.084,974.996,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-11",14,13.58,494.02,,0.001,0.001,250.512,0.0591,0.018,0.0099,4217.428,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-15",21,20.7,830.9,,0.002,0.001,410.68,0.0591,0.045,0.0195,6910.02,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-16",22,21.02,769,,0.002,0.001,388.038,0.059,0.027,0.0085,6529.148,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-28",9,8.27,236.81,,0.001,0.001,144.369,0.0591,0.031,0.0512,2430.011,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-29",24,24,824,,0.002,0.001,477.9,0.0591,0.037,0.0091,8044.3,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-11-30",24,24,898,,0.003,0.001,509.6,0.0593,0.04,0.0093,8575.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-01",22,20.95,688.97,,0.002,0.001,402.819,0.0594,0.047,0.0236,6777.229,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-02",24,24,827,,0.002,0.001,477,0.059,0.036,0.009,8031.9,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-03",24,24,948,,0.003,0.001,532.4,0.0593,0.041,0.0092,8955.5,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-04",23,22.7,860.5,,0.002,0.001,486.82,0.0592,0.04,0.0107,8193.03,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Water Injection,Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-01",24,24,1074,,0.003,0.001,532.3,0.0593,0.03,0.0067,8956.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-02",24,24,1132,,0.003,0.001,555.1,0.0593,0.032,0.0068,9338.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-03",24,24,1266,,0.003,0.001,610.1,0.0592,0.035,0.0068,10266.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-04",24,24,1124,,0.003,0.001,553.4,0.0593,0.032,0.0068,9313.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-05",24,24,997,,0.003,0.001,504.2,0.0591,0.029,0.0068,8486.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-06",24,24,1003,,0.003,0.001,506.5,0.0594,0.029,0.0068,8519.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-07",24,24,1235,,0.003,0.001,597.6,0.0592,0.035,0.0069,10056.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-08",24,24,1069,,0.003,0.001,530.6,0.0592,0.03,0.0067,8926.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-09",24,24,1129,,0.003,0.001,555.9,0.0592,0.032,0.0068,9353.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-10",24,24,1034,,0.003,0.001,516.4,0.0591,0.029,0.0067,8694.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-11",24,24,949,,0.002,0.001,483.3,0.0593,0.028,0.0069,8130.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-12",24,24,1046,,0.003,0.001,523.8,0.0593,0.03,0.0068,8811.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-13",24,24,957,,0.002,0.001,486.2,0.0593,0.028,0.0068,8180.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-14",24,24,1096,,0.003,0.001,541.8,0.0593,0.031,0.0068,9114.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-15",24,24,1037,,0.003,0.001,516.2,0.0592,0.029,0.0068,8687.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-16",24,24,1175,,0.003,0.001,572.3,0.0593,0.033,0.0069,9630,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-17",24,24,1162,,0.003,0.001,565.9,0.0592,0.033,0.0069,9523.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-18",24,24,1195,,0.003,0.001,577.5,0.0592,0.034,0.0069,9717.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-19",24,24,1143,,0.003,0.001,559.2,0.0593,0.033,0.0071,9409.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-20",24,24,1170,,0.003,0.001,570.5,0.0593,0.034,0.007,9600.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-21",24,24,900,,0.002,0.001,464.6,0.0593,0.027,0.007,7816.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-22",24,24,1135,,0.003,0.001,557.9,0.0594,0.032,0.0069,9381.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-23",24,24,1083,,0.003,0.001,537.2,0.0592,0.032,0.007,9036.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-24",24,24,885,,0.002,0.001,455.9,0.0593,0.027,0.007,7669.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-25",24,24,926,,0.002,0.001,469.6,0.0592,0.028,0.007,7905.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-26",24,24,1027,,0.003,0.001,512.2,0.0591,0.03,0.007,8622.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-27",24,24,986,,0.003,0.001,497.7,0.0592,0.029,0.007,8374.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-28",24,24,1060,,0.003,0.001,527.4,0.0593,0.03,0.0067,8872.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-29",24,24,992,,0.003,0.001,499.9,0.0593,0.028,0.0067,8410.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-30",24,24,1017,,0.003,0.001,508.5,0.0593,0.029,0.0067,8553,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-01-31",24,24,921,,0.002,0.001,470.7,0.0594,0.027,0.0069,7915.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-01",23,22.53,834.01,,0.002,0.001,428.989,0.0594,0.024,0.0067,7216.641,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-02",1,0.35,0,,0,0.001,2.135,0.059,0.001,0.072,35.98,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-19",11,10.67,423.7,,0.001,0.001,220.2,0.0592,0.017,0.0121,3705.895,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-20",24,24,1065,,0.003,0.001,529.8,0.0593,0.03,0.0068,8915,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-21",24,24,1134,,0.003,0.001,551.7,0.0591,0.032,0.0069,9289.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-22",24,24,1143,,0.003,0.001,557.3,0.0595,0.031,0.0066,9372.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-23",24,24,1008,,0.003,0.001,501.5,0.0592,0.029,0.0068,8438.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-24",10,9.55,389.35,,0.001,0.001,196.91,0.0593,0.011,0.007,3313.355,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-04",16,15.55,551.3,,0.001,0.001,294.71,0.0594,0.019,0.0095,4955.145,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-05",24,24,1014,,0.003,0.001,505,0.0593,0.029,0.0068,8494.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-06",24,24,835,,0.002,0.001,429.3,0.0593,0.024,0.0068,7226.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-07",24,24,934,,0.002,0.001,470.5,0.0593,0.026,0.0066,7917.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-08",24,24,1090,,0.003,0.001,534.5,0.0591,0.031,0.0068,8999.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-09",24,24,992,,0.002,0.001,493.7,0.0593,0.028,0.0066,8308.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-10",24,24,1129,,0.003,0.001,549.1,0.0593,0.031,0.0067,9239,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-11",24,24,1070,,0.003,0.001,522.7,0.0591,0.03,0.0068,8797.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-12",24,24,1032,,0.003,0.001,508.9,0.0591,0.029,0.0068,8568.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-13",24,24,898,,0.002,0.001,456.3,0.0592,0.026,0.0068,7682.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-14",24,24,1032,,0.003,0.001,511.1,0.0591,0.029,0.0068,8602.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-15",24,24,1292,,0.003,0.001,615.5,0.0592,0.035,0.0068,10356.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-16",24,24,1325,,0.003,0.001,630.7,0.0592,0.038,0.0073,10613.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-17",24,24,1125,,0.003,0.001,545.9,0.0591,0.031,0.0068,9189.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-18",24,24,994,,0.002,0.001,490.4,0.0591,0.028,0.0067,8255.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-19",24,24,972,,0.002,0.001,485.2,0.0593,0.027,0.0067,8162.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-20",24,24,1036,,0.003,0.001,511.7,0.0593,0.029,0.0067,8609.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-21",24,24,1118,,0.003,0.001,540.2,0.0592,0.031,0.0069,9089.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-22",24,24,1035,,0.003,0.001,507.2,0.0592,0.029,0.0068,8534.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-23",24,24,1048,,0.003,0.001,512.9,0.0593,0.029,0.0068,8627.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-24",24,24,1064,,0.003,0.001,519.2,0.0593,0.03,0.0068,8735.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-25",24,24,1087,,0.003,0.001,529.2,0.0593,0.03,0.0068,8905.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-26",24,24,1167,,0.003,0.001,564.7,0.0591,0.033,0.0069,9503.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-27",24,24,945,,0.002,0.001,476,0.0593,0.027,0.0068,8010.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-28",24,24,1131,,0.003,0.001,549.6,0.0593,0.032,0.0068,9248.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-29",24,24,1057,,0.003,0.001,519.6,0.0592,0.03,0.0068,8743.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-30",24,24,1050,,0.003,0.001,515.4,0.0593,0.029,0.0068,8673.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-03-31",24,24,1048,,0.003,0.001,512.4,0.0594,0.029,0.0068,8618.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-01",18,17.27,532.15,,0.002,0.001,296.88,0.0593,0.017,0.0076,4995.769,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-02",24,24,1056,,0.003,0.001,517.8,0.0592,0.029,0.0067,8713.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-03",24,24,1065,,0.003,0.001,521.3,0.0593,0.03,0.0067,8770.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-04",24,24,1119,,0.003,0.001,543.4,0.0593,0.031,0.0068,9142.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-05",24,24,1284,,0.003,0.001,607,0.0592,0.036,0.007,10214.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-06",24,24,1197,,0.003,0.001,570.3,0.0592,0.032,0.0067,9595.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-07",24,24,1023,,0.003,0.001,502.5,0.0592,0.028,0.0067,8455.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-08",24,24,1136,,0.003,0.001,551.5,0.0591,0.031,0.0068,9282.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-09",24,24,1118,,0.003,0.001,543.2,0.0593,0.031,0.0069,9137.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-10",24,24,862,,0.002,0.001,440.5,0.0592,0.024,0.0065,7417.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-11",24,24,900,,0.002,0.001,457.1,0.0594,0.026,0.0069,7687.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-12",24,24,934,,0.002,0.001,471.1,0.0592,0.027,0.0067,7928.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-13",24,24,1002,,0.003,0.001,497.3,0.0594,0.029,0.0068,8363.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-14",24,24,963,,0.002,0.001,481.2,0.0593,0.028,0.0068,8097,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-15",24,24,1098,,0.003,0.001,535.9,0.0591,0.03,0.0067,9017.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-16",24,24,1102,,0.003,0.001,538.2,0.0593,0.031,0.0069,9054,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-17",24,24,882,,0.002,0.001,448.9,0.0591,0.025,0.0066,7554.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-18",24,24,936,,0.002,0.001,472.4,0.0594,0.027,0.0067,7945.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-19",24,24,846,,0.002,0.001,435.3,0.0593,0.025,0.0068,7322,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-20",24,24,1000,,0.003,0.001,498,0.0592,0.029,0.0068,8378.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-21",24,24,993,,0.002,0.001,494.9,0.0594,0.029,0.0069,8325,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-22",24,24,1100,,0.003,0.001,538.9,0.0591,0.031,0.0069,9070.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-23",24,24,1182,,0.003,0.001,570.8,0.0592,0.033,0.0068,9607.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-24",24,24,1024,,0.003,0.001,508.5,0.0592,0.029,0.0068,8557.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-25",24,24,989,,0.002,0.001,494.5,0.0592,0.029,0.0069,8323.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-26",24,24,1048,,0.003,0.001,518.6,0.0593,0.03,0.0068,8728,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-27",24,24,955,,0.002,0.001,482.2,0.0593,0.028,0.0069,8113.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-28",24,24,905,,0.002,0.001,465.7,0.0593,0.026,0.0067,7835.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-29",24,24,935,,0.002,0.001,476.3,0.0592,0.027,0.0068,8021.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-04-30",24,24,771,,0.002,0.001,412.8,0.0593,0.023,0.0068,6947.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-01",24,24,923,,0.002,0.001,479.4,0.0594,0.027,0.0066,8063.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-02",24,24,852,,0.002,0.001,443.8,0.0593,0.025,0.0067,7464.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-03",24,24,916,,0.002,0.001,467.4,0.0592,0.027,0.0069,7865.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-04",12,11.08,364,,0.001,0.001,196.332,0.0593,0.011,0.0093,3303.524,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-08",15,14.13,443.13,,0.001,0.001,260.806,0.0593,0.017,0.0127,4389.894,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-09",24,24,776,,0.002,0.001,409.5,0.0592,0.024,0.007,6892.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-10",24,24,869,,0.002,0.001,448.9,0.0592,0.026,0.0069,7556.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-11",24,24,1131,,0.003,0.001,559.4,0.0592,0.032,0.0069,9412.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-12",24,24,1205,,0.003,0.001,587.8,0.0592,0.034,0.0068,9893.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-13",24,24,1147,,0.003,0.001,561.7,0.0595,0.032,0.0068,9448.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-14",24,24,1020,,0.003,0.001,509.7,0.0594,0.029,0.0067,8573.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-15",24,24,1228,,0.003,0.001,596.9,0.0592,0.034,0.0067,10040.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-16",24,24,1100,,0.003,0.001,541.1,0.0593,0.03,0.0067,9105.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-17",24,24,1202,,0.003,0.001,586.8,0.0594,0.033,0.0068,9870.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-18",24,24,1134,,0.003,0.001,557.3,0.0592,0.031,0.0067,9377.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-19",24,24,990,,0.003,0.001,524,0.0592,0.029,0.0067,8817.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-20",24,24,870,,0.002,0.001,467.4,0.0592,0.026,0.0067,7867.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-21",24,24,910,,0.003,0.001,568.1,0.0591,0.032,0.0067,9562.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-22",24,24,802,,0.002,0.001,469.2,0.0595,0.026,0.0066,7892.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-23",24,24,895,,0.002,0.001,466.6,0.0591,0.027,0.0068,7854.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-24",24,24,1003,,0.003,0.001,513.7,0.0593,0.029,0.0067,8641.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-25",24,24,1039,,0.003,0.001,525.5,0.0591,0.03,0.0069,8844,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-26",24,24,1271,,0.003,0.001,624.9,0.0593,0.036,0.0068,10512.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-27",24,24,1025,,0.003,0.001,523.3,0.0592,0.029,0.0067,8807.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-28",24,24,798,,0.002,0.001,433.4,0.0593,0.025,0.0068,7292.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-29",24,24,704,,0.002,0.001,389.9,0.0593,0.022,0.0068,6560.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-30",24,24,980,,0.003,0.001,503.4,0.0593,0.029,0.0068,8468.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-05-31",24,24,908,,0.002,0.001,470.4,0.0592,0.025,0.0065,7916.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-01",24,24,1299,,0.003,0.001,629.9,0.0592,0.036,0.0068,10598.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-02",24,24,1235,,0.003,0.001,607.4,0.0592,0.034,0.0067,10219.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-03",24,24,1148,,0.003,0.001,568.2,0.0592,0.033,0.007,9561.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-04",21,19.2,669.6,,0.002,0.001,360.1,0.0593,0.021,0.0079,6060.22,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-05",24,24,981,,0.003,0.001,500.7,0.0591,0.028,0.0066,8427.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-06",24,24,961,,0.002,0.001,491.7,0.0592,0.027,0.0067,8274.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-07",5,4.85,182,,0,0.001,94.295,0.059,0.005,0.006,1588.625,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-08",18,18,681,,0.002,0.001,366.5,0.0594,0.022,0.0077,6164.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-09",24,24,975,,0.003,0.001,498.2,0.0593,0.029,0.0068,8381.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-10",24,24,1216,,0.003,0.001,595.2,0.0594,0.034,0.0067,10011.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-11",24,24,1301,,0.003,0.001,628.9,0.0591,0.036,0.0068,10584.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-12",24,24,1275,,0.003,0.001,616.6,0.0592,0.035,0.0068,10375.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-13",24,24,1179,,0.003,0.001,576.9,0.0592,0.032,0.0067,9705.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-14",24,24,1261,,0.003,0.001,609.5,0.0593,0.035,0.0068,10252.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-15",24,24,1246,,0.003,0.001,604.2,0.0592,0.035,0.0068,10170.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-16",24,24,910,,0.002,0.001,470.4,0.0593,0.026,0.0067,7917.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-17",24,24,930,,0.002,0.001,478.5,0.0594,0.027,0.0068,8047.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-18",24,24,965,,0.002,0.001,495.1,0.0593,0.028,0.0067,8327.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-19",24,24,1033,,0.003,0.001,524.6,0.0594,0.029,0.0067,8824.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-20",24,24,864,,0.002,0.001,451.2,0.0593,0.025,0.0067,7590.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-21",24,24,974,,0.003,0.001,496,0.0593,0.028,0.0068,8346,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-22",24,24,1154,,0.003,0.001,573,0.0591,0.032,0.0067,9642.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-23",24,24,1271,,0.003,0.001,620.3,0.059,0.035,0.0068,10439.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-24",24,24,1052,,0.003,0.001,527.5,0.0592,0.03,0.0068,8877.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-25",24,24,1031,,0.003,0.001,520.6,0.0592,0.03,0.0068,8762.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-26",24,24,929,,0.002,0.001,478.4,0.0592,0.027,0.0066,8051.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-27",24,24,1075,,0.003,0.001,535.1,0.0592,0.031,0.0068,9004.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-28",24,24,962,,0.002,0.001,486.4,0.0593,0.027,0.0066,8180.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-29",24,24,1260,,0.003,0.001,606.3,0.0592,0.035,0.0068,10204.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-06-30",24,24,877,,0.002,0.001,454.7,0.0591,0.026,0.0068,7653.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-01",24,24,1275,,0.003,0.001,621.1,0.0592,0.035,0.0068,10446.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-02",24,24,1169,,0.003,0.001,575.9,0.0592,0.032,0.0067,9687.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-03",24,24,1006,,0.003,0.001,506.2,0.0593,0.029,0.0069,8516.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-04",24,24,884,,0.002,0.001,459.9,0.0592,0.026,0.0067,7740.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-05",24,24,970,,0.002,0.001,493.5,0.0591,0.028,0.0068,8307.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-06",24,24,912,,0.002,0.001,470.1,0.0592,0.026,0.0065,7911.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-07",24,24,1008,,0.003,0.001,511,0.0593,0.029,0.0068,8598.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-08",24,24,1209,,0.003,0.001,591.4,0.0593,0.033,0.0067,9951.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-09",24,24,1072,,0.003,0.001,536.8,0.0593,0.03,0.0067,9029,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-10",24,24,1056,,0.003,0.001,526.9,0.0591,0.03,0.0068,8870.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-11",24,24,1036,,0.003,0.001,520.2,0.0592,0.029,0.0066,8753.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-12",24,24,1051,,0.003,0.001,525.5,0.0593,0.029,0.0066,8840.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-13",24,24,1120,,0.003,0.001,549.9,0.0592,0.032,0.0068,9252.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-14",24,24,1133,,0.003,0.001,553.3,0.0593,0.031,0.0066,9307.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-15",24,24,1018,,0.003,0.001,508.3,0.0592,0.028,0.0067,8553,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-16",24,24,1038,,0.003,0.001,515.3,0.0593,0.029,0.0068,8671.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-17",24,24,824,,0.002,0.001,430.1,0.0593,0.024,0.0068,7238.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-18",24,24,863,,0.002,0.001,446.3,0.0593,0.025,0.0067,7507.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-19",24,24,984,,0.003,0.001,496.7,0.0592,0.028,0.0067,8359.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-20",24,24,808,,0.002,0.001,424.5,0.0593,0.024,0.0066,7143.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-21",24,24,1036,,0.003,0.001,516.2,0.0593,0.029,0.0067,8683.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-22",24,24,987,,0.003,0.001,496,0.0593,0.029,0.007,8345.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-23",24,24,999,,0.003,0.001,499.1,0.0592,0.028,0.0065,8397.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-24",24,24,1195,,0.003,0.001,577.3,0.0591,0.032,0.0065,9714,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-25",24,24,1298,,0.003,0.001,621.8,0.0593,0.036,0.0068,10460.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-26",24,24,1362,,0.003,0.001,645.2,0.0593,0.037,0.0068,10854.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-27",24,24,1233,,0.003,0.001,593.3,0.0592,0.034,0.0068,9985.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-28",24,24,1241,,0.003,0.001,600.4,0.0591,0.034,0.0068,10105.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-29",24,24,1211,,0.003,0.001,585.4,0.0593,0.034,0.0069,9848.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-30",24,24,889,,0.002,0.001,458.7,0.0593,0.026,0.0067,7718.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-07-31",24,24,817,,0.002,0.001,429,0.0593,0.024,0.0066,7218.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-01",24,24,821,,0.002,0.001,425.5,0.0592,0.025,0.007,7164.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-02",24,24,1011,,0.003,0.001,504.2,0.0591,0.029,0.007,8487,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-03",24,24,1213,,0.003,0.001,586.9,0.0591,0.033,0.0067,9876,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-04",24,24,1319,,0.003,0.001,627,0.0593,0.036,0.0068,10550.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-05",24,24,1286,,0.003,0.001,607.6,0.0592,0.035,0.0068,10224.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-06",24,24,1029,,0.003,0.001,503.9,0.0592,0.028,0.0067,8479.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-07",24,24,1166,,0.003,0.001,562.4,0.0592,0.032,0.0068,9464.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-08",24,24,1198,,0.003,0.001,576,0.0592,0.033,0.0068,9694.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-09",24,24,1234,,0.003,0.001,593.4,0.0593,0.034,0.0068,9981.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-10",24,24,1200,,0.003,0.001,582.2,0.0592,0.033,0.0067,9797.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-11",1,0.33,1.65,,0,0.001,2.211,0.06,0,0.011,37.125,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-13",9,8.55,272.85,,0.001,0.001,161.795,0.0592,0.01,0.0094,2724.655,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-14",24,24,1060,,0.003,0.001,521.7,0.0593,0.031,0.0071,8777.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-15",16,14.94,462.93,,0.001,0.001,287.618,0.0593,0.017,0.0083,4840.984,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-16",15,14.77,894.63,,0.002,0.001,460.826,0.0591,0.027,0.0074,7752.225,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-17",24,24,1664,,0.004,0.001,820,0.059,0.048,0.0069,13804.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-18",24,24,1620,,0.004,0.001,802.8,0.0591,0.045,0.0067,13510.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-19",24,24,1179,,0.003,0.001,571.1,0.0593,0.033,0.007,9610.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-20",24,24,982,,0.002,0.001,490,0.0593,0.029,0.0072,8246.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-21",24,24,1162,,0.003,0.001,564,0.0593,0.034,0.0071,9489.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-22",24,24,1257,,0.003,0.001,601.9,0.0593,0.035,0.0069,10125.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-23",24,24,1323,,0.003,0.001,630.4,0.0591,0.037,0.0069,10608.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-24",24,24,1358,,0.003,0.001,648,0.0593,0.037,0.0068,10902.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-25",24,24,1325,,0.003,0.001,630.7,0.0593,0.036,0.0068,10610.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-26",24,24,954,,0.002,0.001,477.5,0.0592,0.027,0.0068,8036.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-27",24,24,996,,0.002,0.001,491.9,0.0593,0.028,0.0068,8277.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-28",24,24,1129,,0.003,0.001,549.8,0.0591,0.032,0.007,9251.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-29",24,24,1193,,0.003,0.001,576.4,0.0593,0.033,0.0067,9696.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-30",24,24,980,,0.002,0.001,488,0.0593,0.029,0.0072,8211.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-08-31",24,24,1191,,0.003,0.001,578,0.0592,0.033,0.0068,9725.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-01",23,21.83,855.23,,0.002,0.001,434.53,0.0592,0.025,0.0076,7312.654,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-02",24,24,1043,,0.003,0.001,512.2,0.0593,0.029,0.0068,8618.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-03",24,24,1135,,0.003,0.001,552.2,0.0593,0.033,0.007,9290.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-04",24,24,1189,,0.003,0.001,573.6,0.0592,0.034,0.007,9653,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-05",24,24,1161,,0.003,0.001,564.9,0.0592,0.033,0.0069,9508.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-06",24,24,1329,,0.003,0.001,636.7,0.0593,0.037,0.007,10709.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-07",24,24,1326,,0.003,0.001,632.7,0.0591,0.037,0.007,10647.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-08",24,24,1249,,0.003,0.001,610.6,0.0591,0.035,0.0069,10277.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-09",24,24,1061,,0.003,0.001,523.7,0.0593,0.03,0.0068,8812.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-10",19,18.88,829.72,,0.002,0.001,410.26,0.0592,0.024,0.0072,6903.996,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-11",15,13.29,601.12,,0.002,0.001,302.29,0.0594,0.019,0.014,5085.317,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-12",24,24,1218,,0.003,0.001,586.8,0.0591,0.034,0.0069,9876.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-13",24,24,1251,,0.003,0.001,601.4,0.0593,0.034,0.0068,10117.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-14",24,24,1177,,0.003,0.001,570.6,0.0593,0.033,0.0068,9601.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-15",22,21.52,1177.04,,0.003,0.001,559.756,0.0593,0.032,0.0067,9418.076,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-16",21,20.28,991.12,,0.003,0.001,496.644,0.0593,0.029,0.0074,8355.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-17",24,24,1645,,0.004,0.001,794,0.0591,0.046,0.0069,13357.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-18",24,24,1499,,0.004,0.001,723.5,0.0592,0.042,0.0068,12173.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-19",24,24,1252,,0.003,0.001,602.1,0.0593,0.035,0.007,10128,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-20",24,24,1073,,0.003,0.001,529.5,0.0593,0.031,0.0069,8908.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-21",24,24,1087,,0.003,0.001,539.7,0.0592,0.03,0.0067,9081.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-22",24,24,1078,,0.003,0.001,533.4,0.0593,0.031,0.0068,8975.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-23",24,24,1145,,0.003,0.001,558.8,0.0592,0.032,0.0068,9403.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-24",24,24,1280,,0.003,0.001,611.8,0.0591,0.035,0.0068,10296.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-25",24,24,1158,,0.003,0.001,561.3,0.0591,0.033,0.0069,9445.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-26",24,24,1112,,0.003,0.001,540.5,0.0591,0.031,0.0068,9095.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-27",24,24,1224,,0.003,0.001,584.1,0.0593,0.034,0.0068,9827.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-28",24,24,1063,,0.003,0.001,522.4,0.0593,0.031,0.007,8788.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-29",24,24,1292,,0.003,0.001,617.2,0.0591,0.035,0.0068,10389.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-09-30",24,24,1175,,0.003,0.001,566.7,0.0592,0.032,0.0068,9539,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-01",24,24,1063,,0.003,0.001,522.4,0.0593,0.03,0.007,8786.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-02",24,24,834,,0.002,0.001,428.5,0.0593,0.026,0.0071,7210.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-03",24,24,985,,0.002,0.001,491.9,0.0592,0.028,0.0068,8279,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-04",24,24,1144,,0.003,0.001,552,0.0593,0.032,0.0068,9287.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-05",24,24,1278,,0.003,0.001,601,0.0594,0.036,0.007,10108.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-06",24,24,1282,,0.003,0.001,597.8,0.0593,0.035,0.007,10056,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-07",24,24,1142,,0.003,0.001,540.2,0.0594,0.031,0.0069,9085.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-08",24,24,1024,,0.002,0.001,492.2,0.0596,0.028,0.0067,8275.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-09",24,24,1255,,0.003,0.001,584.6,0.0591,0.033,0.0067,9843.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-10",24,24,1327,,0.003,0.001,613.3,0.0592,0.035,0.0068,10320,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-11",24,24,1324,,0.003,0.001,612.8,0.0591,0.035,0.0068,10313.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-12",24,24,1249,,0.003,0.001,584.1,0.0592,0.033,0.0068,9829,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-13",24,24,1118,,0.003,0.001,532.7,0.0593,0.03,0.0067,8961,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-14",24,24,1361,,0.003,0.001,636.7,0.0592,0.034,0.0064,10713,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-15",24,24,1157,,0.003,0.001,550.8,0.0592,0.031,0.0066,9269,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-16",24,24,972,,0.002,0.001,475.3,0.0594,0.027,0.0067,7993.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-17",24,24,851,,0.002,0.001,424.7,0.0591,0.024,0.0068,7151.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-18",24,24,834,,0.002,0.001,419.7,0.0593,0.024,0.0067,7060.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-19",24,24,1189,,0.003,0.001,563.8,0.059,0.032,0.0068,9487.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-20",24,24,1163,,0.003,0.001,555.4,0.0592,0.031,0.0066,9345,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-21",24,24,1214,,0.003,0.001,575.3,0.0594,0.033,0.0068,9675.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-22",24,24,1213,,0.003,0.001,572.1,0.0592,0.032,0.0067,9630.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-23",24,24,908,,0.002,0.001,447.6,0.0592,0.025,0.0066,7531.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-24",24,24,1320,,0.003,0.001,618.1,0.0591,0.036,0.007,10401.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-25",24,24,1173,,0.003,0.001,561.6,0.0593,0.032,0.0068,9445.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-26",24,24,1215,,0.003,0.001,583.7,0.0591,0.033,0.0068,9824.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-27",24,24,1254,,0.003,0.001,597.3,0.0592,0.034,0.0068,10049.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-28",24,24,1241,,0.003,0.001,587.9,0.0592,0.034,0.0068,9894.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-29",24,24,1227,,0.003,0.001,581.4,0.0593,0.033,0.0067,9780.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-30",24,24,1063,,0.003,0.001,517,0.0593,0.029,0.0067,8693.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-10-31",24,24,1100,,0.003,0.001,529.2,0.0591,0.03,0.0068,8907.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-01",24,24,1222,,0.003,0.001,579.7,0.0593,0.033,0.0068,9753.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-02",24,24,1157,,0.003,0.001,554.5,0.0592,0.032,0.0068,9330.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-03",24,24,1114,,0.003,0.001,535.7,0.0592,0.031,0.0068,9013.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-04",24,24,1229,,0.003,0.001,581.7,0.059,0.033,0.0067,9790.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-05",24,24,1177,,0.003,0.001,559.7,0.0591,0.032,0.0068,9421.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-06",24,24,1262,,0.003,0.001,593.9,0.0592,0.034,0.0068,9993.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-07",24,24,1192,,0.003,0.001,567.1,0.0592,0.033,0.0068,9542.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-08",24,24,1143,,0.003,0.001,544.2,0.0593,0.031,0.0067,9153.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-09",24,24,1253,,0.003,0.001,592.2,0.0591,0.033,0.0067,9968.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-10",24,24,1252,,0.003,0.001,592.2,0.0594,0.033,0.0067,9958.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-11",24,24,1077,,0.003,0.001,519.9,0.0591,0.029,0.0067,8752.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-12",24,24,1026,,0.003,0.001,499.7,0.0593,0.028,0.0068,8409.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-13",24,24,1065,,0.003,0.001,515.5,0.0593,0.029,0.0067,8673.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-14",24,24,1116,,0.003,0.001,535.4,0.0594,0.03,0.0068,9002.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-15",24,24,1239,,0.003,0.001,591.5,0.0593,0.032,0.0065,9953.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-16",24,24,1171,,0.003,0.001,566.3,0.0591,0.032,0.0068,9530.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-17",24,24,1216,,0.003,0.001,581.5,0.0593,0.033,0.0067,9783.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-18",24,24,1063,,0.003,0.001,518.2,0.0593,0.029,0.0067,8721.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-19",24,24,1040,,0.003,0.001,513.8,0.0593,0.029,0.0068,8644.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-20",24,24,1070,,0.003,0.001,523.4,0.0592,0.03,0.0068,8807.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-21",24,24,1141,,0.003,0.001,559.4,0.0593,0.032,0.0068,9411,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-22",24,24,1043,,0.003,0.001,515.2,0.0592,0.029,0.0067,8669.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-23",24,24,943,,0.002,0.001,473.2,0.0592,0.027,0.0068,7963.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-24",24,24,1119,,0.003,0.001,547.9,0.0592,0.031,0.0067,9218.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-25",24,24,1106,,0.003,0.001,543.4,0.0591,0.031,0.0068,9144.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-26",24,24,1164,,0.003,0.001,566.6,0.0591,0.033,0.0069,9537.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-27",24,24,1113,,0.003,0.001,547.9,0.0594,0.031,0.0068,9214.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-28",23,22.97,942.73,,0.002,0.001,473.751,0.0592,0.027,0.0068,7971.015,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-29",1,0.1,0,,0,0.001,0.82,0.06,0,0.023,13.72,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-04",9,8.75,269,,0.001,0.001,158.925,0.0592,0.009,0.0077,2674.525,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-05",24,24,1412,,0.003,0.001,681.3,0.059,0.036,0.0062,11468.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-06",24,24,1341,,0.003,0.001,650.3,0.0591,0.038,0.0069,10942.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-07",24,24,1264,,0.003,0.001,615.5,0.0593,0.035,0.0068,10354.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-08",24,24,1265,,0.003,0.001,614.4,0.0593,0.035,0.0068,10335.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-09",24,24,1210,,0.003,0.001,592.2,0.0592,0.034,0.0069,9966.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-10",24,24,1161,,0.003,0.001,570.4,0.0593,0.032,0.0068,9598.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-11",24,24,1025,,0.003,0.001,514.9,0.0593,0.029,0.0068,8663.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-12",24,24,1088,,0.003,0.001,541.4,0.059,0.031,0.0069,9114.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-13",24,24,1255,,0.003,0.001,607.2,0.0593,0.035,0.0068,10215,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-14",24,24,864,,0.002,0.001,448.9,0.0592,0.025,0.0068,7554.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-15",24,24,1177,,0.003,0.001,578.5,0.0593,0.033,0.0067,9734.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-16",24,24,1154,,0.003,0.001,568.7,0.0592,0.032,0.0067,9570.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-17",24,24,1037,,0.003,0.001,518.6,0.0591,0.029,0.0068,8726.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-18",24,24,1090,,0.003,0.001,540.9,0.0592,0.031,0.0068,9102.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-19",24,24,1229,,0.003,0.001,599.8,0.0593,0.034,0.0068,10088.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-20",24,24,1317,,0.003,0.001,639.9,0.0592,0.037,0.0069,10765.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-21",24,24,1069,,0.003,0.001,533.8,0.0592,0.03,0.0068,8983.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-22",24,24,1189,,0.003,0.001,584.9,0.0591,0.034,0.0068,9847.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-23",24,24,1226,,0.003,0.001,601.2,0.0592,0.034,0.0068,10118.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-24",24,24,1242,,0.003,0.001,606.1,0.0591,0.035,0.0068,10199.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-25",24,24,1081,,0.003,0.001,537.4,0.0592,0.031,0.0068,9044.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-26",24,24,975,,0.002,0.001,491.5,0.0593,0.028,0.0068,8269.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-27",24,24,923,,0.002,0.001,473,0.0592,0.027,0.0068,7958.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-28",24,24,871,,0.002,0.001,449.7,0.0593,0.025,0.0066,7567.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-29",24,24,926,,0.002,0.001,475.7,0.0592,0.027,0.0067,8004.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-30",24,24,1215,,0.003,0.001,596.1,0.0592,0.033,0.0066,10029.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Woodland Generation Station",7266,"2",,"2020-12-31",24,24,1096,,0.003,0.001,544.6,0.0593,0.031,0.0068,9158.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-16",18,17.35,727,,0.002,0.001,360.72,0.0591,0.034,0.0253,6071.01,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-17",22,21.1,876.8,,0.002,0.001,422.14,0.0594,0.022,0.009,7103.79,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-18",14,13.52,467.52,,0.001,0.001,245.308,0.0594,0.026,0.0246,4125.268,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-19",24,24,916,,0.002,0.001,455.6,0.0592,0.017,0.0045,7668.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-20",24,24,1050,,0.003,0.001,502.7,0.059,0.018,0.0043,8461.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-21",24,24,1053,,0.003,0.001,503.8,0.0595,0.021,0.0048,8471.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-22",24,24,964,,0.002,0.001,475.6,0.0594,0.024,0.006,8003.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-23",24,24,1087,,0.003,0.001,517.9,0.0592,0.022,0.0051,8717.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-24",24,24,975,,0.002,0.001,475.7,0.0594,0.021,0.0054,8002.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-25",24,24,939,,0.002,0.001,464.9,0.0594,0.019,0.005,7819.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-26",24,24,921,,0.002,0.001,455.1,0.0591,0.021,0.0055,7660.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-27",24,24,913,,0.002,0.001,456.1,0.0595,0.023,0.0061,7674.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-28",24,24,968,,0.002,0.001,473.7,0.0593,0.027,0.0067,7972.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-29",24,24,1003,,0.002,0.001,487.5,0.0591,0.028,0.0069,8207.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-30",24,24,991,,0.002,0.001,481.3,0.0592,0.021,0.0053,8100.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-01-31",24,24,1039,,0.003,0.001,498.2,0.0593,0.021,0.0051,8379.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-01",24,24,944,,0.002,0.001,466.5,0.0592,0.023,0.0058,7850.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-02",24,24,856,,0.002,0.001,433.9,0.0592,0.024,0.0067,7304.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-03",24,24,1031,,0.003,0.001,499.4,0.0595,0.018,0.0043,8398.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-04",24,24,1084,,0.003,0.001,516.7,0.0593,0.017,0.0039,8690.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-05",24,24,1170,,0.003,0.001,544.8,0.0591,0.026,0.0057,9170.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-06",24,24,1153,,0.003,0.001,538.3,0.0594,0.027,0.006,9054.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-07",24,24,1162,,0.003,0.001,543.6,0.0594,0.022,0.0049,9143.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-08",24,24,1101,,0.003,0.001,518.1,0.0592,0.016,0.0037,8722.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-09",24,24,1142,,0.003,0.001,537.4,0.0593,0.022,0.005,9037.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-10",24,24,1141,,0.003,0.001,535.1,0.0592,0.027,0.006,9005.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-11",24,24,1060,,0.003,0.001,502.9,0.0593,0.02,0.0046,8461.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-12",24,24,979,,0.002,0.001,472.6,0.0593,0.022,0.0054,7950.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-13",24,24,1105,,0.003,0.001,525.5,0.0593,0.018,0.004,8840.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-14",24,24,1054,,0.003,0.001,501.7,0.0595,0.024,0.0058,8436,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-15",24,24,993,,0.002,0.001,478.7,0.0595,0.025,0.0061,8050.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-16",24,24,1037,,0.003,0.001,499.9,0.0592,0.015,0.0035,8410.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-17",24,24,900,,0.002,0.001,448.9,0.0593,0.02,0.0052,7553.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-18",24,24,962,,0.002,0.001,472.9,0.0593,0.015,0.0038,7957.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-19",24,24,973,,0.002,0.001,478.1,0.0593,0.017,0.0043,8046.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-20",24,24,1032,,0.003,0.001,498.2,0.0594,0.022,0.0054,8383.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-21",24,24,1008,,0.002,0.001,488,0.0593,0.014,0.0034,8212.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-22",24,24,965,,0.002,0.001,472.8,0.0594,0.017,0.0044,7953.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-23",24,24,1025,,0.002,0.001,494.9,0.0594,0.019,0.0046,8324.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-24",24,24,1052,,0.003,0.001,506.5,0.0592,0.021,0.005,8521.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-25",24,24,1053,,0.003,0.001,507.1,0.0592,0.019,0.0045,8536.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-26",24,24,1068,,0.003,0.001,504.6,0.0592,0.018,0.0043,8493.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-27",24,24,1032,,0.002,0.001,494,0.0595,0.013,0.003,8304.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-28",22,21.97,922.89,,0.002,0.001,446.769,0.0594,0.018,0.0049,7515.545,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-10",1,0.5,0,,0,0.001,3.6,0.06,0.006,0.21,60.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-16",2,0.52,0.75,,0,0.001,4.399,0.06,0.007,0.197,73.691,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-18",1,0.58,0,,0,0.001,4.64,0.06,0.01,0.263,77.836,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-23",2,0.07,0,,0,0.001,0.267,0.0595,0,0.085,4.493,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-25",18,17.43,605.43,,0.002,0.001,305.81,0.0592,0.025,0.0209,5148.21,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-26",19,18.25,736.25,,0.002,0.001,356.45,0.0592,0.008,0.0027,5999.025,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-06",13,12.42,461,,0.001,0.001,235.54,0.0594,0.025,0.0278,3964.466,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-07",24,24,981,,0.002,0.001,468.7,0.0591,0.018,0.0045,7887.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-08",24,24,1083,,0.003,0.001,503.3,0.0593,0.015,0.0035,8464.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-09",24,24,1107,,0.003,0.001,510.4,0.0594,0.018,0.0041,8586.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-10",24,24,1151,,0.003,0.001,521.3,0.0592,0.023,0.0052,8779.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-11",24,24,1051,,0.002,0.001,489.2,0.0592,0.019,0.0046,8232,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-12",24,24,1020,,0.002,0.001,481.4,0.0592,0.017,0.0043,8101.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-13",24,24,1094,,0.003,0.001,501.7,0.0594,0.013,0.0029,8439.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-14",24,24,990,,0.002,0.001,471.3,0.0594,0.01,0.0024,7929.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-15",24,24,985,,0.002,0.001,466.8,0.0592,0.011,0.0029,7858.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-16",24,24,1046,,0.002,0.001,487.5,0.0593,0.007,0.0016,8199.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-17",24,24,971,,0.002,0.001,460.7,0.0592,0.007,0.0018,7755.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-18",24,24,1098,,0.003,0.001,505.6,0.0592,0.012,0.0028,8510.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-19",24,24,1131,,0.003,0.001,520.1,0.0593,0.019,0.0043,8750.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-20",24,24,1034,,0.002,0.001,484,0.0592,0.011,0.0026,8145,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-21",24,23.18,939.4,,0.002,0.001,447.64,0.0591,0.01,0.0035,7533.756,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-26",18,17.45,690.45,,0.002,0.001,334.305,0.0596,0.022,0.0178,5621.11,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-27",24,24,1106,,0.003,0.001,509.9,0.0592,0.016,0.0038,8580.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-28",24,24,1060,,0.002,0.001,492.9,0.0592,0.019,0.0045,8296.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-29",24,24,969,,0.002,0.001,460.6,0.0593,0.015,0.0039,7750.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-30",24,24,834,,0.002,0.001,409.9,0.0594,0.014,0.0042,6893.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-07-31",24,24,859,,0.002,0.001,419.6,0.0592,0.014,0.004,7068.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-01",24,24,861,,0.002,0.001,421.1,0.0593,0.015,0.0043,7084.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-02",24,24,930,,0.002,0.001,447.6,0.0592,0.017,0.0044,7532.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-03",24,24,982,,0.002,0.001,461.7,0.0592,0.018,0.0047,7769.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-04",24,24,1098,,0.003,0.001,506.9,0.0592,0.017,0.004,8531,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-05",24,24,1212,,0.003,0.001,542.6,0.0593,0.018,0.0039,9129.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-06",24,24,988,,0.002,0.001,466.4,0.0594,0.016,0.004,7846.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-07",24,24,1076,,0.003,0.001,499.3,0.0594,0.02,0.0047,8400.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-08",24,24,1023,,0.002,0.001,474.8,0.0592,0.008,0.002,7989.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-09",24,24,1062,,0.002,0.001,491.5,0.0593,0.012,0.0029,8265.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-10",24,24,1098,,0.003,0.001,503.4,0.0592,0.016,0.0036,8472.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-11",24,24,1052,,0.002,0.001,490.6,0.0593,0.013,0.0032,8252.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-12",24,24,1089,,0.003,0.001,499.5,0.0592,0.017,0.0041,8407.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-13",24,24,974,,0.002,0.001,460,0.0592,0.015,0.0039,7743,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-14",24,24,1091,,0.003,0.001,505.8,0.0593,0.022,0.0051,8513.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-15",24,24,1191,,0.003,0.001,537.9,0.0591,0.017,0.0035,9056.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-16",24,24,1044,,0.002,0.001,483.6,0.0593,0.015,0.0036,8133.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-17",24,24,968,,0.002,0.001,457.7,0.0592,0.01,0.0027,7700.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-18",24,24,1089,,0.003,0.001,506.4,0.0593,0.008,0.0019,8520,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-19",24,24,1080,,0.003,0.001,495.7,0.0591,0.014,0.0034,8347.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-20",24,24,908,,0.002,0.001,436.8,0.0593,0.016,0.0044,7355.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-21",24,24,811,,0.002,0.001,403.3,0.0593,0.01,0.0029,6786.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-22",24,24,819,,0.002,0.001,405.9,0.0591,0.005,0.0014,6832.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-23",24,24,924,,0.002,0.001,441.7,0.0593,0.012,0.0033,7433.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-24",24,24,944,,0.002,0.001,448.9,0.0593,0.01,0.0026,7552.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-25",24,24,961,,0.002,0.001,454.6,0.0596,0.013,0.0035,7642.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-26",24,24,946,,0.002,0.001,448.9,0.059,0.011,0.0028,7559.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-27",24,24,982,,0.002,0.001,461.7,0.0592,0.012,0.0031,7773.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-28",24,24,1054,,0.002,0.001,486.1,0.0593,0.013,0.0033,8178.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-29",24,24,942,,0.002,0.001,447.5,0.0591,0.008,0.0023,7536,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-30",24,24,1017,,0.002,0.001,476.6,0.0594,0.013,0.0033,8016.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-08-31",24,24,996,,0.002,0.001,465.1,0.0593,0.015,0.0039,7826.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-01",24,24,1079,,0.003,0.001,498.5,0.0592,0.015,0.0035,8386.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-02",24,24,1030,,0.002,0.001,477,0.0593,0.014,0.0035,8026.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-03",24,24,1065,,0.003,0.001,495.6,0.0592,0.013,0.0032,8339.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-04",24,24,1031,,0.002,0.001,483.7,0.0593,0.011,0.0027,8136.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-05",24,24,911,,0.002,0.001,441.6,0.0592,0.008,0.0022,7433.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-06",24,24,1044,,0.002,0.001,488.7,0.0594,0.012,0.0029,8222,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-07",24,24,1082,,0.003,0.001,502.2,0.0593,0.014,0.0032,8449.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-08",24,24,1027,,0.002,0.001,481.6,0.0591,0.014,0.0035,8105.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-09",24,24,942,,0.002,0.001,451.9,0.0593,0.019,0.0049,7600.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-10",24,24,1015,,0.002,0.001,480.4,0.0593,0.015,0.0037,8081.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-11",24,24,1016,,0.002,0.001,479.1,0.0591,0.015,0.0036,8060,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-12",24,24,1004,,0.002,0.001,472.7,0.0593,0.013,0.0033,7950.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-13",24,24,1078,,0.003,0.001,498.5,0.0593,0.016,0.0038,8384.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-14",24,24,1037,,0.002,0.001,488.5,0.0594,0.011,0.0028,8216.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-15",24,24,1078,,0.003,0.001,502.4,0.059,0.012,0.0028,8458.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-16",24,24,1103,,0.003,0.001,509.4,0.0592,0.017,0.004,8571.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-17",10,9.02,375,,0.001,0.001,177.9,0.059,0.003,0.0042,2996.684,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-28",19,18.35,775,,0.002,0.001,372.15,0.0593,0.026,0.0172,6264.41,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-29",24,24,916,,0.002,0.001,445.5,0.0592,0.013,0.0035,7500.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-09-30",24,24,1046,,0.002,0.001,492.7,0.0593,0.014,0.0033,8288.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-01",24,24,1137,,0.003,0.001,527.2,0.0593,0.018,0.004,8866.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-02",24,24,977,,0.002,0.001,467.3,0.0594,0.012,0.003,7859.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-03",24,24,1076,,0.003,0.001,501.9,0.0593,0.015,0.0035,8445.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-04",24,24,930,,0.002,0.001,452.5,0.0591,0.01,0.0028,7616.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-05",24,24,1050,,0.002,0.001,488.4,0.0592,0.013,0.0032,8221.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-06",24,24,959,,0.002,0.001,456.8,0.0593,0.007,0.0019,7689,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-07",24,24,1016,,0.002,0.001,476.9,0.0593,0.009,0.0022,8021.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-08",24,24,1085,,0.003,0.001,498.2,0.0591,0.014,0.0032,8385.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-09",24,24,1074,,0.003,0.001,497.8,0.0593,0.012,0.0028,8377.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-10",24,24,1033,,0.002,0.001,485.5,0.0592,0.019,0.0046,8165.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-11",24,24,1039,,0.002,0.001,487.4,0.0593,0.021,0.0052,8197.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-12",24,24,1249,,0.003,0.001,564.1,0.0591,0.019,0.004,9494.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-13",24,24,1123,,0.003,0.001,516.2,0.0593,0.018,0.0042,8685.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-14",24,24,1144,,0.003,0.001,521.4,0.0592,0.021,0.0048,8771.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-15",24,24,1183,,0.003,0.001,533.5,0.0592,0.015,0.0035,8981,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-16",24,24,1271,,0.003,0.001,567.1,0.0595,0.015,0.0032,9535.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-17",24,24,1219,,0.003,0.001,552.2,0.0593,0.015,0.0033,9289.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-18",24,24,1204,,0.003,0.001,547.7,0.0592,0.015,0.0031,9217.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-19",24,24,1115,,0.003,0.001,512.8,0.0593,0.014,0.0033,8626.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-20",24,24,1164,,0.003,0.001,530.8,0.0592,0.01,0.0023,8928.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-21",24,24,1056,,0.002,0.001,494.7,0.0591,0.01,0.0024,8330.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-22",24,24,1096,,0.003,0.001,506.7,0.0592,0.013,0.0032,8531.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-23",24,24,1046,,0.002,0.001,491.8,0.059,0.017,0.0042,8277.7,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-24",24,24,981,,0.002,0.001,467.7,0.0593,0.019,0.0048,7869.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-25",24,24,966,,0.002,0.001,465.6,0.0593,0.018,0.0046,7831.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-26",24,24,1079,,0.003,0.001,507.3,0.0594,0.018,0.0041,8532.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-27",24,24,1110,,0.003,0.001,515.5,0.0593,0.012,0.0028,8672.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-28",24,24,1011,,0.002,0.001,479.5,0.0593,0.016,0.004,8067.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-29",24,24,988,,0.002,0.001,470.8,0.0593,0.015,0.0036,7921.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-30",24,24,967,,0.002,0.001,463.6,0.0593,0.017,0.0043,7800.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-10-31",24,24,1035,,0.002,0.001,487.3,0.0593,0.012,0.0029,8196.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-01",24,24,1048,,0.003,0.001,496.4,0.0593,0.015,0.0035,8352.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-02",10,9.25,399.75,,0.001,0.001,193.05,0.0591,0.005,0.0041,3248.775,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-01",2,0.05,0,,0,0.0005,0.126,0.0595,0,0.087,2.119,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-02",9,8.43,352.43,,0.001,0.001,181.927,0.0592,0.031,0.0424,3062.156,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-03",24,24,1203,,0.003,0.001,559.2,0.0593,0.02,0.0043,9408.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-04",24,24,1081,,0.003,0.001,516.3,0.0593,0.016,0.0037,8686.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-05",24,24,1059,,0.003,0.001,505.9,0.0594,0.013,0.0031,8510.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-06",24,24,1012,,0.003,0.001,575.9,0.0593,0.016,0.0033,9687.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-07",24,24,812,,0.003,0.001,529.5,0.0592,0.012,0.0026,8910.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-08",24,24,852,,0.003,0.001,542,0.0594,0.02,0.0043,9116.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-09",24,24,826,,0.003,0.001,530.8,0.0592,0.023,0.0051,8936.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-10",24,24,818,,0.003,0.001,504.4,0.0593,0.019,0.0045,8490.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-11",24,24,1021,,0.002,0.001,495,0.0591,0.016,0.0039,8331.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-12",24,24,909,,0.002,0.001,453.6,0.0595,0.014,0.0037,7628.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-13",24,24,1087,,0.003,0.001,523.3,0.0592,0.015,0.0034,8805.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-14",24,24,1190,,0.003,0.001,560.6,0.0593,0.019,0.004,9429.9,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-15",24,24,1143,,0.003,0.001,540,0.0593,0.019,0.0042,9083.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-16",24,24,1182,,0.003,0.001,550.9,0.0592,0.016,0.0035,9268.2,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-17",24,24,1101,,0.003,0.001,526,0.0594,0.016,0.0035,8846.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-18",24,24,1070,,0.003,0.001,512.5,0.0593,0.013,0.0031,8620.4,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-19",24,24,1205,,0.003,0.001,564,0.0591,0.015,0.0031,9489.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-20",24,24,1112,,0.003,0.001,529.5,0.0593,0.016,0.0036,8909,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-21",24,24,1144,,0.003,0.001,540.3,0.0592,0.021,0.0047,9091,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-22",24,24,1180,,0.003,0.001,554.5,0.0594,0.022,0.0047,9324.8,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-23",24,24,1046,,0.003,0.001,504.2,0.0592,0.016,0.0037,8482.3,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-24",24,24,1098,,0.003,0.001,524.6,0.0594,0.014,0.0033,8826.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-25",24,24,1075,,0.003,0.001,512.8,0.0591,0.015,0.0035,8631.5,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-26",24,24,920,,0.002,0.001,461.9,0.0595,0.012,0.0032,7766.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-27",24,24,1021,,0.002,0.001,494.3,0.0593,0.012,0.0028,8318.1,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-28",24,24,1059,,0.003,0.001,510.2,0.0592,0.017,0.004,8586.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-29",24,24,1085,,0.003,0.001,520.6,0.0591,0.015,0.0033,8761.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-30",24,24,1158,,0.003,0.001,546.7,0.0592,0.016,0.0034,9199.6,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"5",,"2020-12-31",10,9.1,403.2,,0.001,0.001,194.54,0.0593,0.004,0.0078,3273.47,"Pipeline Natural Gas",,"Combined cycle",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-01",24,24,1054,,0.003,0.001,519.6,0.0593,0.024,0.0055,8739.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-02",24,24,1053,,0.003,0.001,517.8,0.0592,0.027,0.0063,8715.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-03",24,24,1078,,0.003,0.001,526,0.059,0.029,0.0065,8854.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-04",24,24,1078,,0.003,0.001,527.2,0.0592,0.024,0.0055,8873.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-05",24,24,1006,,0.003,0.001,503.3,0.0591,0.022,0.0053,8471.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-06",24,24,1168,,0.003,0.001,560.2,0.0593,0.03,0.0063,9424.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-07",24,24,1082,,0.003,0.001,530.6,0.0592,0.025,0.0057,8926.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-08",24,24,1095,,0.003,0.001,535.1,0.0592,0.028,0.0062,9006.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-09",24,24,994,,0.002,0.001,493,0.0595,0.024,0.0059,8289.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-10",24,24,1174,,0.003,0.001,557.5,0.0592,0.028,0.006,9378.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-11",24,24,1032,,0.003,0.001,501.8,0.0593,0.028,0.0068,8442.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-12",24,24,1114,,0.003,0.001,536,0.0594,0.022,0.0048,9017.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-13",24,24,1050,,0.003,0.001,512.2,0.0592,0.023,0.0055,8617.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-14",24,24,1106,,0.003,0.001,534.8,0.0593,0.027,0.006,8997.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-15",24,24,1096,,0.003,0.001,531.6,0.0593,0.024,0.0054,8944,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-16",24,24,1178,,0.003,0.001,557.5,0.0592,0.025,0.0053,9381.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-17",24,24,1067,,0.003,0.001,514.4,0.0592,0.024,0.0056,8657.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-18",24,24,1069,,0.003,0.001,522.2,0.0593,0.023,0.0053,8785.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-19",24,24,954,,0.002,0.001,470.9,0.0592,0.021,0.0053,7922.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-20",24,24,1068,,0.003,0.001,512.4,0.0592,0.018,0.0043,8619.6,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-21",24,24,1047,,0.003,0.001,507.6,0.0595,0.024,0.0057,8534.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-22",24,24,990,,0.002,0.001,486.4,0.0593,0.023,0.0055,8182.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-23",24,24,1100,,0.003,0.001,527.1,0.0591,0.021,0.0049,8872.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-24",24,24,986,,0.002,0.001,485.5,0.0595,0.024,0.0058,8163,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-25",24,24,964,,0.002,0.001,474.2,0.0593,0.021,0.0052,7974.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-26",24,24,939,,0.002,0.001,464.5,0.0593,0.021,0.0054,7817.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-27",24,24,899,,0.002,0.001,451.8,0.0594,0.022,0.0059,7601.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-28",24,24,996,,0.002,0.001,486.6,0.0592,0.027,0.0067,8189.6,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-29",24,24,1078,,0.003,0.001,514.5,0.0593,0.023,0.0053,8659.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-30",24,24,1013,,0.002,0.001,491.3,0.0591,0.022,0.0053,8272.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-01-31",24,24,1053,,0.003,0.001,506.4,0.0592,0.02,0.0048,8520.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-01",24,24,977,,0.002,0.001,479.7,0.0592,0.02,0.005,8073.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-02",24,24,874,,0.002,0.001,443,0.0593,0.019,0.005,7451.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-03",22,21.07,910.28,,0.002,0.001,440.637,0.0593,0.018,0.01,7412.003,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-10",1,0.3,0,,0,0.001,2.34,0.059,0.005,0.243,39.45,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-17",1,0.88,1.76,,0,0.001,7.304,0.06,0.012,0.198,122.408,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-19",18,17.4,740,,0.002,0.001,361.24,0.0592,0.03,0.0216,6079.28,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-20",24,24,1037,,0.002,0.001,494.9,0.0592,0.009,0.0023,8326.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-21",24,24,1137,,0.003,0.001,534.2,0.0592,0.01,0.0024,8985.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-22",24,24,1151,,0.003,0.001,538.3,0.0592,0.012,0.0027,9058.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-23",24,24,1142,,0.003,0.001,536.5,0.0592,0.009,0.0022,9028.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-24",24,24,1029,,0.003,0.001,495,0.0594,0.01,0.0024,8328,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-25",24,24,883,,0.002,0.001,441.7,0.0591,0.014,0.0037,7435.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-26",24,24,1045,,0.003,0.001,495.4,0.0594,0.011,0.0026,8333.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-27",24,23.32,1105.96,,0.003,0.001,517.7,0.0592,0.015,0.0042,8714.536,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-01",18,17.4,698,,0.002,0.001,346.38,0.0592,0.032,0.0218,5830.78,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-02",24,24,1072,,0.003,0.001,508.3,0.0593,0.018,0.0042,8551.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-03",24,24,974,,0.002,0.001,473.1,0.0594,0.019,0.0048,7961.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-04",24,24,991,,0.002,0.001,480.3,0.059,0.018,0.0044,8087,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-05",24,24,1113,,0.003,0.001,528.2,0.0592,0.018,0.0041,8889.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-06",14,13.47,555.87,,0.001,0.001,272.309,0.059,0.009,0.0046,4582.984,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-13",18,17.4,702,,0.002,0.001,337.06,0.0593,0.025,0.0183,5671.44,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-14",24,24,1014,,0.002,0.001,478.2,0.0593,0.016,0.0039,8043.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-15",24,24,1001,,0.002,0.001,475.2,0.0594,0.015,0.0038,7993.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-16",24,24,1061,,0.002,0.001,494.4,0.0594,0.014,0.0035,8314.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-17",24,24,990,,0.002,0.001,467.5,0.0593,0.014,0.0034,7863.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-18",24,24,1115,,0.003,0.001,515.2,0.0593,0.012,0.0028,8665.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-19",24,24,1159,,0.003,0.001,531.4,0.0592,0.019,0.0043,8941.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-20",24,24,1051,,0.002,0.001,490.4,0.0593,0.019,0.0045,8250.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-21",24,24,1002,,0.002,0.001,474.1,0.0592,0.014,0.0035,7975.6,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-22",24,24,1080,,0.003,0.001,505.6,0.0592,0.017,0.004,8508,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-23",24,24,1003,,0.002,0.001,479.5,0.0592,0.016,0.004,8072.6,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-24",24,24,1083,,0.003,0.001,507,0.0592,0.019,0.0045,8535.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-25",24,24,1175,,0.003,0.001,543.3,0.0593,0.018,0.004,9144.6,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-26",24,24,1015,,0.002,0.001,481.9,0.0592,0.013,0.0033,8109.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-27",24,24,1039,,0.002,0.001,488.8,0.0591,0.014,0.0035,8233.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-28",24,24,1088,,0.003,0.001,505.4,0.0593,0.017,0.0038,8504.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-29",24,24,944,,0.002,0.001,454.7,0.0593,0.015,0.0039,7649.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-30",24,24,938,,0.002,0.001,451.9,0.0593,0.015,0.0039,7604.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-07-31",24,24,888,,0.002,0.001,430.9,0.0593,0.013,0.0036,7250.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-01",24,24,900,,0.002,0.001,438.9,0.0593,0.017,0.0045,7386.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-02",24,24,956,,0.002,0.001,458.8,0.0593,0.018,0.0047,7718.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-03",24,24,996,,0.002,0.001,468.3,0.0592,0.019,0.0048,7885.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-04",23,23,1022,,0.002,0.001,472.8,0.0592,0.016,0.0041,7957.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-07",18,17.37,748.37,,0.002,0.001,355.812,0.0592,0.034,0.0234,5990.308,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-08",24,24,1015,,0.002,0.001,480,0.0594,0.013,0.0034,8074.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-09",24,24,1078,,0.003,0.001,503.9,0.0595,0.015,0.0037,8476.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-10",24,24,1092,,0.003,0.001,507.7,0.0592,0.014,0.0034,8549,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-11",24,24,1072,,0.003,0.001,499.6,0.0593,0.014,0.0033,8405.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-12",24,24,1083,,0.003,0.001,503.5,0.0592,0.017,0.0039,8472.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-13",24,24,1111,,0.003,0.001,517.1,0.0591,0.016,0.0038,8702.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-14",24,24,1110,,0.003,0.001,515.6,0.0593,0.017,0.004,8674.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-15",24,24,1170,,0.003,0.001,537,0.0592,0.015,0.0033,9036.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-16",24,24,1052,,0.002,0.001,494.7,0.0591,0.017,0.004,8325.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-17",24,24,958,,0.002,0.001,460.5,0.0593,0.016,0.0042,7745.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-18",24,24,995,,0.002,0.001,472.6,0.0593,0.015,0.0038,7950.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-19",24,24,1021,,0.002,0.001,482.6,0.0594,0.018,0.0044,8119,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-20",24,24,870,,0.002,0.001,428.7,0.0592,0.016,0.0045,7214.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-21",24,24,816,,0.002,0.001,412.1,0.0595,0.013,0.0038,6928.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-22",24,24,834,,0.002,0.001,415.4,0.0592,0.008,0.0023,6988.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-23",24,24,934,,0.002,0.001,450.2,0.0593,0.01,0.0025,7574.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-24",24,24,951,,0.002,0.001,456.8,0.0592,0.014,0.0038,7687.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-25",24,24,942,,0.002,0.001,453.7,0.0593,0.013,0.0033,7636.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-26",24,24,958,,0.002,0.001,458.6,0.0593,0.014,0.0036,7714.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-27",24,24,997,,0.002,0.001,470.6,0.0593,0.015,0.0038,7922.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-28",24,24,1055,,0.002,0.001,494.7,0.0591,0.013,0.0033,8324.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-29",24,24,968,,0.002,0.001,462.6,0.0594,0.016,0.004,7780.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-30",24,24,983,,0.002,0.001,468.4,0.0593,0.017,0.0042,7884.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-08-31",24,24,976,,0.002,0.001,465.2,0.0593,0.015,0.0038,7830.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-01",24,24,1123,,0.003,0.001,517.2,0.0591,0.014,0.0032,8711,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-02",24,24,1030,,0.002,0.001,483.4,0.0592,0.014,0.0035,8134.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-03",24,24,1077,,0.003,0.001,506.6,0.0594,0.014,0.0033,8519.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-04",24,24,986,,0.002,0.001,473.6,0.0593,0.015,0.0037,7970.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-05",24,24,947,,0.002,0.001,458.3,0.0594,0.015,0.0037,7711,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-06",24,24,1011,,0.002,0.001,481.5,0.0594,0.015,0.0036,8097.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-07",24,24,1071,,0.003,0.001,505,0.0594,0.013,0.003,8496.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-08",24,24,1023,,0.002,0.001,486.3,0.0591,0.015,0.0038,8187.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-09",24,24,957,,0.002,0.001,462,0.0594,0.015,0.0038,7773.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-10",19,18.92,805.88,,0.002,0.001,384.848,0.0596,0.014,0.0044,6470.744,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-17",17,16.25,724.5,,0.002,0.001,345.65,0.0593,0.026,0.0218,5815.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-18",24,24,1158,,0.003,0.001,542.4,0.0593,0.014,0.003,9126.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-19",24,24,1028,,0.002,0.001,493,0.0591,0.01,0.0025,8300.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-20",24,24,1171,,0.003,0.001,545.7,0.0592,0.016,0.0035,9182.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-21",24,24,1074,,0.003,0.001,512.1,0.0595,0.012,0.0028,8611.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-22",24,24,1022,,0.002,0.001,491.9,0.0592,0.015,0.0037,8277.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-23",24,24,988,,0.002,0.001,476.9,0.059,0.015,0.0036,8029,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-24",24,24,1097,,0.003,0.001,517.5,0.0592,0.015,0.0034,8711.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-25",24,24,997,,0.002,0.001,479.5,0.0592,0.015,0.0037,8070.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-26",24,24,1017,,0.002,0.001,489,0.0593,0.013,0.0033,8227.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-27",24,24,1075,,0.003,0.001,510.4,0.0591,0.015,0.0036,8591.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-28",24,24,1032,,0.002,0.001,492.4,0.0593,0.015,0.0037,8286.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-29",24,24,939,,0.002,0.001,454.6,0.0594,0.014,0.0036,7646.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-09-30",24,24,1053,,0.003,0.001,498.7,0.0593,0.012,0.003,8393.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-01",24,24,1077,,0.003,0.001,509.6,0.0591,0.015,0.0035,8578.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-02",24,23.05,920.05,,0.002,0.001,446.48,0.0593,0.016,0.009,7512.095,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-02",17,16.4,703.2,,0.002,0.001,334.76,0.0592,0.031,0.021,5636.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-03",24,24,1045,,0.003,0.001,495.5,0.0594,0.016,0.004,8336.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-04",24,24,1080,,0.003,0.001,508.1,0.0594,0.016,0.0036,8548,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-05",24,24,1099,,0.003,0.001,512.9,0.0593,0.015,0.0035,8626.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-06",24,24,1040,,0.002,0.001,492.8,0.0593,0.013,0.0031,8294,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-07",24,24,1003,,0.002,0.001,481,0.0591,0.02,0.005,8098.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-08",24,24,1006,,0.002,0.001,483.2,0.0595,0.015,0.0037,8125.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-09",24,24,1180,,0.003,0.001,548.3,0.0592,0.016,0.0034,9227.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-10",24,24,1216,,0.003,0.001,566.5,0.0593,0.022,0.0045,9531.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-11",24,24,910,,0.003,0.001,511.5,0.0592,0.015,0.0034,8608.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-12",24,24,736,,0.003,0.001,500,0.0593,0.012,0.0029,8411.3,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-13",24,24,951,,0.003,0.001,528.3,0.0591,0.015,0.0034,8898.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-14",24,24,1054,,0.003,0.001,505.6,0.0592,0.016,0.0038,8506.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-15",24,24,1118,,0.003,0.001,527.4,0.0592,0.016,0.0037,8873.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-16",24,24,1105,,0.003,0.001,522.4,0.0592,0.018,0.004,8792.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-17",24,24,1022,,0.002,0.001,494.7,0.0595,0.017,0.004,8319.6,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-18",24,24,991,,0.002,0.001,483.9,0.0593,0.014,0.0035,8144.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-19",24,24,1089,,0.003,0.001,522.4,0.0595,0.016,0.0038,8785.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-20",24,24,1046,,0.003,0.001,502.4,0.0593,0.016,0.0038,8454.4,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-21",24,24,1111,,0.003,0.001,526.9,0.059,0.017,0.0038,8869.6,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-22",24,24,1094,,0.003,0.001,524.7,0.0594,0.015,0.0034,8826.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-23",24,24,1058,,0.003,0.001,511.5,0.0594,0.017,0.0039,8603,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-24",24,24,1083,,0.003,0.001,515.8,0.0593,0.016,0.0037,8677.1,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-25",24,24,995,,0.002,0.001,488.3,0.0593,0.017,0.0041,8215.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-26",24,24,988,,0.002,0.001,483,0.0592,0.016,0.0039,8126.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-27",24,24,974,,0.002,0.001,480.4,0.0592,0.012,0.003,8082.7,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-28",24,24,1073,,0.003,0.001,517,0.0593,0.015,0.0035,8698.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-29",24,24,1124,,0.003,0.001,535.4,0.0592,0.017,0.0038,9008.9,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-11-30",24,24,1196,,0.003,0.001,563.3,0.0591,0.015,0.0032,9480.8,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-01",24,24,1190,,0.003,0.001,558.9,0.0593,0.017,0.0036,9396.2,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-02",18,17.52,832,,0.002,0.001,400.08,0.0591,0.015,0.0049,6733.5,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-30",1,0.07,0,,0,0.001,0.546,0.059,0.001,0.182,9.212,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Redding Power Plant",7307,"6",,"2020-12-31",17,16.4,608.6,,0.002,0.001,309.82,0.0592,0.027,0.019,5213.24,"Pipeline Natural Gas",,"Combustion turbine",,"Other",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-16",2,0.2,0,,0,0.0005,0.728,0.0595,0.001,0.094,12.189,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-13",19,17.3,620.23,,0.002,0.001,343.16,0.0594,0.042,0.0289,5773.223,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-14",18,16.3,626.25,,0.002,0.001,343.565,0.0594,0.036,0.0249,5775.835,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-01",9,8.65,271.55,,0.001,0.001,156.005,0.0592,0.026,0.0401,2625.53,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-02",24,24,799,,0.002,0.001,455.1,0.0593,0.038,0.01,7661.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-03",24,24,812,,0.002,0.001,460.1,0.0593,0.039,0.01,7742.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-04",24,24,766,,0.002,0.001,438.5,0.0593,0.037,0.01,7376.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-05",24,24,772,,0.002,0.001,442.9,0.0594,0.037,0.01,7451.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-06",24,24,769,,0.002,0.001,441.3,0.0595,0.038,0.0102,7420.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-07",24,24,742,,0.002,0.001,430,0.0592,0.036,0.01,7237.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-08",24,24,749,,0.002,0.001,433,0.0591,0.036,0.0099,7289.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-09",24,24,768,,0.002,0.001,439.7,0.0592,0.037,0.01,7398.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-10",24,24,642,,0.002,0.001,385.6,0.0591,0.032,0.01,6493.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-11",24,24,831,,0.002,0.001,464.7,0.0592,0.039,0.0099,7821.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-12",24,24,867,,0.002,0.001,481.9,0.0591,0.043,0.0106,8114.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-13",24,24,876,,0.002,0.001,489.1,0.0593,0.041,0.01,8230.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-14",24,24,817,,0.002,0.001,462.8,0.0594,0.039,0.01,7784.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-15",24,24,864,,0.002,0.001,479.9,0.0592,0.04,0.01,8079.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-16",24,24,844,,0.002,0.001,472.5,0.0591,0.04,0.01,7952.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-17",14,13.82,485.32,,0.001,0.001,270.038,0.0595,0.034,0.0174,4540.806,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-19",18,17.27,505,,0.002,0.001,297.377,0.0593,0.033,0.0231,5004.601,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-20",24,24,838,,0.002,0.001,470.9,0.0592,0.04,0.01,7922.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-21",24,24,914,,0.003,0.001,504.4,0.0593,0.042,0.01,8486.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-22",24,24,680,,0.002,0.001,403.5,0.0593,0.034,0.01,6788.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-23",24,24,669,,0.002,0.001,402.1,0.0593,0.033,0.0098,6764.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-24",24,24,769,,0.002,0.001,443.2,0.059,0.037,0.01,7459,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-25",21,20.03,671,,0.002,0.001,381.972,0.0594,0.033,0.0168,6425.406,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-03",13,11.32,415.6,,0.001,0.0009,229.14,0.0595,0.032,0.0423,3855.938,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-04",15,13.31,517.56,,0.001,0.001,284.452,0.0594,0.032,0.034,4785.326,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-10",10,8.33,269.3,,0.001,0.001,154.669,0.0591,0.026,0.0551,2604.877,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-11",13,11.79,432.38,,0.001,0.001,240.912,0.0592,0.027,0.0265,4055.13,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-22",19,17.32,712,,0.002,0.001,386.24,0.0593,0.043,0.0272,6497.028,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-23",19,17.81,761.38,,0.002,0.001,411.861,0.0594,0.04,0.0198,6927.879,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-24",20,18.82,786.88,,0.002,0.001,426.41,0.0593,0.041,0.0198,7176.38,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-25",13,11.32,409,,0.001,0.001,227.748,0.0594,0.027,0.0321,3830.56,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-26",13,11.3,441,,0.001,0.001,242.02,0.0594,0.027,0.0326,4070.33,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-13",12,10.8,367,,0.001,0.001,206.64,0.0594,0.03,0.0347,3476.38,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-14",12,10.3,387,,0.001,0.001,213.5,0.0595,0.026,0.0363,3591.66,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-15",11,9.8,353.6,,0.001,0.001,197.34,0.0593,0.025,0.0316,3321.22,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-17",9,7.3,249,,0.001,0.001,140.69,0.0591,0.017,0.0398,2366.32,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-19",10,9.28,336.2,,0.001,0.001,187.396,0.0592,0.025,0.0286,3155.024,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-20",16,14.8,600.8,,0.002,0.001,328.264,0.0594,0.034,0.0214,5522.78,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-21",11,9.3,361,,0.001,0.001,198.32,0.0593,0.024,0.037,3336.59,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-26",13,11.3,461,,0.001,0.001,250.37,0.0594,0.033,0.0378,4211.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-27",14,12.28,495,,0.001,0.001,269.922,0.0592,0.03,0.0327,4541.534,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-28",15,14.07,594.4,,0.002,0.001,321.525,0.0593,0.033,0.0236,5410.687,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-29",15,13.26,563,,0.002,0.001,303.142,0.0593,0.034,0.0293,5100.126,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-30",16,14.3,569,,0.002,0.001,310.89,0.0591,0.033,0.0298,5232.27,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-07-31",14,12.33,398.13,,0.001,0.001,228.009,0.0593,0.026,0.0301,3837.497,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-01",11,9.3,370,,0.001,0.001,201.31,0.0591,0.02,0.0373,3388.83,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-03",16,14.32,585,,0.002,0.001,317.04,0.0594,0.036,0.0315,5332.912,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-04",16,14.27,599,,0.002,0.001,324.387,0.0594,0.034,0.028,5455.082,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-05",16,14.3,590,,0.002,0.001,317.42,0.0594,0.033,0.0276,5338.92,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-07",13,11.75,475.37,,0.001,0.001,257.884,0.0592,0.031,0.0295,4339.645,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-08",14,12.25,502,,0.001,0.001,270.984,0.0591,0.031,0.0313,4564.88,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-09",14,12.26,511,,0.001,0.001,276.052,0.0592,0.031,0.0311,4644.442,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-10",20,18.33,699,,0.002,0.001,384.302,0.0593,0.038,0.0239,6465.827,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-11",14,12.26,505,,0.001,0.001,272.068,0.0594,0.031,0.0312,4577.328,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-12",18,16.25,610,,0.002,0.001,335.785,0.0592,0.035,0.0254,5652.469,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-13",17,15.32,567,,0.002,0.001,315.652,0.0591,0.033,0.0264,5314.422,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-14",17,15.3,565,,0.002,0.001,311.91,0.0593,0.034,0.0275,5247.46,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-15",10,8.8,302,,0.001,0.001,169.74,0.0595,0.021,0.033,2855.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-16",14,11.38,387,,0.001,0.001,217.48,0.0594,0.026,0.0374,3659.354,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-17",14,12.8,473.4,,0.001,0.001,262.2,0.0591,0.03,0.0269,4415.04,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-18",13,11.3,404,,0.001,0.001,225.11,0.0595,0.026,0.0339,3784.43,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-19",13,11.3,354,,0.001,0.001,205.21,0.0593,0.025,0.0344,3452.71,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-20",11,9.26,298,,0.001,0.001,169.652,0.0595,0.023,0.0407,2854.04,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-21",10,8.8,323.5,,0.001,0.001,179.118,0.0592,0.023,0.0334,3015.18,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-22",10,8.3,301,,0.001,0.001,167.556,0.0591,0.024,0.0427,2822.83,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-23",11,9.3,296,,0.001,0.001,170.086,0.0596,0.023,0.0389,2857.266,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-24",12,10.26,414,,0.001,0.001,226.662,0.0592,0.027,0.0353,3815.03,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-25",11,9.26,375,,0.001,0.001,204.178,0.0594,0.026,0.0381,3432.388,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-26",13,11.76,447.48,,0.001,0.001,245.68,0.0594,0.028,0.0285,4134.328,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-27",10,8.33,287,,0.001,0.001,162.099,0.0594,0.022,0.0433,2726.301,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-28",12,10.3,383,,0.001,0.001,212.394,0.0594,0.026,0.0363,3569.336,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-29",11,9.28,298,,0.001,0.001,170.72,0.0595,0.024,0.0404,2871.492,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-30",8,6.32,202,,0.001,0.001,115.42,0.0591,0.018,0.0521,1944.11,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-03",1,0.08,0,,0,0.001,0.216,0.06,0,0.127,3.616,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-04",14,12.8,496.18,,0.001,0.001,271.732,0.0593,0.034,0.0309,4571.486,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-05",16,14.3,549,,0.002,0.001,303.524,0.0593,0.033,0.0288,5107.306,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-06",12,10.81,395.03,,0.001,0.001,220.041,0.0593,0.026,0.0268,3701.544,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-07",10,9,347.5,,0.001,0.001,191.102,0.0593,0.025,0.0352,3215.36,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-08",10,8.3,248,,0.001,0.001,144.294,0.0594,0.021,0.0468,2425.614,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-09",7,5.3,144,,0,0.001,86.77,0.0591,0.016,0.0556,1460.678,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-10",8,6.26,178,,0.001,0.001,106.332,0.0596,0.017,0.0474,1787.892,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-12",8,6.49,179.84,,0.001,0.001,107.927,0.0593,0.02,0.0443,1816.005,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-14",11,9.3,328,,0.001,0.001,185.302,0.0594,0.025,0.0382,3118.024,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-15",13,11.3,371,,0.001,0.001,212.994,0.0593,0.026,0.0335,3582.242,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-16",13,11.34,401,,0.001,0.001,225.666,0.0592,0.026,0.0318,3797.608,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-17",10,8.32,295,,0.001,0.001,165.238,0.0591,0.022,0.0395,2779.888,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-21",11,9.3,334,,0.001,0.001,189.306,0.0594,0.027,0.043,3185.936,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-22",10,8.3,277,,0.001,0.001,159.852,0.0593,0.021,0.0419,2689.43,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-23",11,9.81,355.3,,0.001,0.001,199.471,0.0595,0.025,0.0294,3356.091,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-24",10,8.31,283,,0.001,0.001,160.586,0.0593,0.021,0.0394,2702.663,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-27",11,9.8,322.7,,0.001,0.001,184.654,0.0593,0.026,0.034,3106.522,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-28",13,11.3,434,,0.001,0.001,241.036,0.0594,0.029,0.0348,4053.886,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-29",13,11.3,402,,0.001,0.001,226.358,0.0592,0.027,0.033,3812.412,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-09-30",11,9.31,294,,0.001,0.001,170.417,0.0593,0.022,0.0381,2868.426,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-01",11,9.3,297,,0.001,0.001,172.612,0.0595,0.022,0.0365,2902.029,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-02",11,9.25,297.18,,0.001,0.001,172.83,0.0595,0.023,0.0377,2905.39,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-03",9,7.83,244.34,,0.001,0.001,143.617,0.0593,0.021,0.0376,2416.89,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-05",10,8.82,270.5,,0.001,0.001,155.965,0.0593,0.023,0.0344,2625.81,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-06",11,9.83,325.46,,0.001,0.001,182.349,0.0591,0.023,0.0278,3072.236,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-07",15,13.3,483.23,,0.001,0.001,265.605,0.0593,0.03,0.0289,4466.909,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-08",10,8.84,291.92,,0.001,0.001,164.268,0.0592,0.02,0.0281,2762.572,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-13",14,12.5,417.43,,0.001,0.001,234.526,0.0591,0.029,0.0288,3946.569,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-14",16,14.2,475,,0.001,0.001,266.276,0.0592,0.03,0.0296,4481.68,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-15",15,13.32,446.25,,0.001,0.001,250.344,0.0593,0.028,0.0298,4214.393,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-16",14,12.3,394,,0.001,0.001,224.219,0.0594,0.025,0.0311,3772.866,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-17",12,10.32,356.25,,0.001,0.001,197.644,0.0595,0.024,0.0371,3324.382,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-18",12,10.3,324,,0.001,0.001,184.575,0.0592,0.023,0.0367,3106.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-19",13,11.8,376.06,,0.001,0.001,214.18,0.0592,0.025,0.0276,3604.076,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-20",13,10.91,273.78,,0.001,0.0009,167.998,0.0597,0.025,0.027,2822.48,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-21",13,9.3,268,,0.001,0.0009,156.888,0.0588,0.022,0.0392,2643.624,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-22",12,10.8,288.3,,0.001,0.001,173.024,0.0591,0.023,0.0303,2913.984,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-23",16,14.31,460.23,,0.001,0.001,260.994,0.0594,0.028,0.0286,4388.02,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-25",15,14.25,460,,0.001,0.001,265.125,0.0594,0.035,0.0287,4462,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-26",24,24,801,,0.002,0.001,457.1,0.0594,0.037,0.0098,7688,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-27",24,24,782,,0.002,0.001,448.5,0.0593,0.037,0.0099,7540.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-28",24,24,861,,0.002,0.001,482.9,0.0594,0.04,0.0098,8123.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-29",24,24,871,,0.002,0.001,488.2,0.0595,0.04,0.0097,8210.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-11-30",24,24,898,,0.003,0.001,500.1,0.0593,0.04,0.0095,8417.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-01",24,24,910,,0.003,0.001,501.1,0.0594,0.04,0.0094,8427.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-02",24,24,969,,0.003,0.001,525.8,0.0593,0.042,0.0095,8845.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-03",24,24,858,,0.002,0.001,479.9,0.0593,0.038,0.0093,8077.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-04",24,24,864,,0.002,0.001,482.1,0.0591,0.037,0.0092,8116,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-05",24,24,864,,0.002,0.001,481.4,0.0594,0.037,0.0091,8095.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-06",24,24,867,,0.002,0.001,483.3,0.0594,0.039,0.0096,8131.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-07",24,24,1043,,0.003,0.001,558.3,0.0591,0.046,0.0098,9398.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-08",24,24,864,,0.002,0.001,481,0.0591,0.037,0.0092,8093.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-09",24,24,833,,0.002,0.001,465.9,0.0595,0.038,0.0097,7836.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-10",24,24,956,,0.003,0.001,517.1,0.0592,0.043,0.0098,8706.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-11",24,24,1012,,0.003,0.001,543.2,0.059,0.044,0.0095,9142.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-12",24,24,909,,0.003,0.001,500.2,0.0595,0.04,0.0096,8412.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-13",24,24,851,,0.002,0.001,475.9,0.0594,0.039,0.0097,8005,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-14",24,24,862,,0.002,0.001,478.6,0.0595,0.04,0.0099,8047.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-15",24,24,888,,0.002,0.001,490.8,0.0592,0.039,0.0095,8257.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-16",24,24,861,,0.002,0.001,480.3,0.0593,0.038,0.0095,8082.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-17",1,0.05,0,,0,0.001,0.18,0.059,0,0.125,3.045,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-22",1,0.08,0,,0,0.001,0.224,0.059,0,0.113,3.824,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction,Steam Injection",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-08",9,7.19,290.32,,0.001,0.001,170.882,0.0593,0.013,0.0222,2874.859,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-13",8,6.29,181.52,,0.001,0.001,116.65,0.0591,0.009,0.0163,1964.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-15",18,16.57,715.54,,0.002,0.001,414.71,0.0592,0.029,0.0098,6977.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-20",4,3.13,100.56,,0,0.001,62.982,0.0593,0.005,0.0283,1060.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-21",12,11.07,491,,0.001,0.001,282.327,0.0591,0.019,0.0091,4751.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-29",16,15.03,532,,0.002,0.001,324.589,0.0592,0.023,0.0163,5461.577,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-30",24,24,807,,0.003,0.001,502.3,0.0593,0.034,0.008,8455.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-01-31",24,24,822,,0.003,0.001,508.3,0.0592,0.034,0.008,8552.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-01",24,24,824,,0.003,0.001,508.4,0.0595,0.034,0.008,8551.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-02",24,24,741,,0.002,0.001,469.9,0.0593,0.032,0.008,7902.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-03",9,8.55,273.7,,0.001,0.001,171.91,0.0594,0.012,0.0081,2891.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-11",19,17.35,814.84,,0.002,0.001,460.773,0.0591,0.032,0.0152,7755.346,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-18",8,6.9,224.9,,0.001,0.001,140.79,0.0594,0.011,0.0105,2368.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-25",8,6.75,243.95,,0.001,0.001,147.802,0.0591,0.011,0.0208,2488.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-26",3,1.52,30.94,,0,0.001,23.068,0.059,0.003,0.029,388.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-12",1,0.13,0,,0,0.001,0.78,0.06,0.001,0.225,13.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-16",9,8.1,274.75,,0.001,0.001,169.213,0.0593,0.013,0.0099,2848.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-17",17,16.52,644.94,,0.002,0.001,381.793,0.0591,0.027,0.0085,6425.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-04",1,0.15,0,,0,0.001,0.9,0.06,0.002,0.208,15.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-06",2,0.53,9.68,,0,0.001,7.317,0.059,0.002,0.0295,123.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-08",8,6.77,273.62,,0.001,0.001,161.014,0.0594,0.012,0.0308,2708.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-09",10,9.2,343.6,,0.001,0.001,206.26,0.0593,0.014,0.0079,3471.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-26",4,2.33,38.9,,0,0.001,31.051,0.0593,0.003,0.0415,522.751,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-27",8,6.75,197.87,,0.001,0.0009,128.461,0.0593,0.01,0.01,2161.458,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-02",8,6.27,232.2,,0.001,0.001,139.7,0.0594,0.011,0.0158,2349.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-03",9,7.15,253.43,,0.001,0.0009,152.448,0.0592,0.011,0.0188,2566.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-04",11,9.48,480.26,,0.001,0.001,268.268,0.0592,0.019,0.0196,4514.858,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-10",11,10,408.8,,0.001,0.001,239.024,0.0594,0.018,0.0209,4021.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-11",6,4.15,158.1,,0,0.001,94.075,0.0592,0.007,0.029,1583.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-19",11,10.06,460.62,,0.001,0.001,264.369,0.0594,0.019,0.0091,4447.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-22",5,4.21,196.91,,0.001,0.001,111.98,0.059,0.009,0.0094,1885.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-23",8,6.23,271.2,,0.001,0.001,157.159,0.0591,0.012,0.0154,2644.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-24",11,10.17,444.21,,0.001,0.001,257.571,0.0594,0.018,0.0088,4332.743,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-25",18,17.09,779.46,,0.002,0.001,445.121,0.0592,0.031,0.0085,7491.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-26",17,15.95,752.42,,0.002,0.001,427.612,0.0591,0.03,0.0088,7193.803,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-27",10,8.75,430.55,,0.001,0.001,242.135,0.0591,0.018,0.0093,4074.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-01",5,4.08,133.56,,0,0.001,83.082,0.059,0.007,0.0102,1398.402,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-10",9,7.68,341.4,,0.001,0.001,196.436,0.0592,0.015,0.01,3308.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-11",4,2.95,91.1,,0,0.001,57.636,0.059,0.005,0.0128,970.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-12",7,5.69,226.54,,0.001,0.001,133.012,0.0591,0.01,0.0263,2238.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-20",7,6.45,247.54,,0.001,0.001,147.156,0.0591,0.01,0.008,2476.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-27",9,7.63,306.44,,0.001,0.001,180.487,0.0591,0.013,0.0108,3038.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-28",8,7.01,300.04,,0.001,0.001,173.807,0.0591,0.012,0.0085,2924.837,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-29",11,9.2,412.15,,0.001,0.001,236.13,0.0594,0.017,0.021,3974.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-30",10,8.7,361.95,,0.001,0.001,210.93,0.0592,0.015,0.0099,3549.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-07-31",9,7.55,263.69,,0.001,0.001,161.101,0.0591,0.012,0.0104,2710.781,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-02",6,5.68,207.54,,0.001,0.001,125.066,0.059,0.01,0.0098,2105.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-03",9,8.01,321.25,,0.001,0.001,189.299,0.0593,0.013,0.0084,3183.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-04",9,8.07,333.3,,0.001,0.001,193.43,0.0592,0.013,0.0083,3255.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-05",7,5.35,222.05,,0.001,0.001,128.995,0.0591,0.01,0.0184,2170.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-06",7,5.97,254.5,,0.001,0.001,146.317,0.0594,0.011,0.0099,2461.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-07",6,5.05,208.04,,0.001,0.001,121.493,0.0592,0.009,0.0095,2043.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-09",3,1.8,81.12,,0,0.001,46.66,0.0593,0.005,0.012,786.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-10",10,8.65,381.4,,0.001,0.001,218.689,0.0591,0.016,0.0098,3681.467,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-11",8,7.37,280.66,,0.001,0.001,165.643,0.059,0.012,0.0098,2787.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-12",9,7.45,291.29,,0.001,0.001,170.98,0.0592,0.013,0.011,2876.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-13",10,8.1,322,,0.001,0.001,188.714,0.0594,0.013,0.0091,3176.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-14",11,9.72,350.21,,0.001,0.001,211.191,0.059,0.015,0.0147,3556.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-15",12,10.71,386.19,,0.001,0.001,231.52,0.0595,0.016,0.0095,3894.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-16",11,10.2,350.12,,0.001,0.001,214.369,0.0594,0.015,0.0094,3606.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-17",16,14.12,483.8,,0.002,0.0009,296.922,0.0593,0.021,0.0168,4997.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-18",16,15.02,545.55,,0.002,0.001,330.587,0.0592,0.023,0.0088,5561.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-19",11,9.53,333.5,,0.001,0.001,203.424,0.0594,0.014,0.0174,3422.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-20",14,13.33,455.03,,0.001,0.001,280.339,0.0591,0.02,0.0088,4717.194,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-21",16,14.95,504.96,,0.002,0.001,311.549,0.0592,0.022,0.0086,5242.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-22",12,11.6,358.16,,0.001,0.001,226.584,0.0594,0.016,0.0088,3809.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-23",11,8.23,289.9,,0.001,0.001,176.535,0.0593,0.013,0.0245,2970.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-24",12,11.4,459.83,,0.001,0.001,268.8,0.0592,0.019,0.0086,4522.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-25",16,14.79,582.56,,0.002,0.001,343.112,0.0592,0.024,0.0088,5774.371,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-26",10,8.18,304.66,,0.001,0.001,181.138,0.0593,0.013,0.0219,3049.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-28",10,9.07,384.13,,0.001,0.001,220.98,0.0592,0.015,0.0081,3717.791,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-08-31",10,8.54,207.81,,0.001,0.001,141.8,0.0594,0.01,0.009,2386.173,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-01",8,6.8,284.1,,0.001,0.001,164.69,0.0595,0.012,0.0094,2770.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-03",13,11.06,472,,0.001,0.001,272.369,0.0594,0.019,0.0186,4583.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-05",11,9.16,329.48,,0.001,0.001,199.712,0.059,0.015,0.0248,3363.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-06",15,14.52,535.11,,0.002,0.001,323.475,0.0591,0.023,0.0085,5444.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-07",14,13.27,437.13,,0.001,0.001,270.055,0.0593,0.019,0.0087,4545.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-08",8,7.06,210.54,,0.001,0.001,135.064,0.0591,0.01,0.0096,2274.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-17",2,0.93,27.93,,0,0.001,17.703,0.059,0.003,0.0355,298.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-23",1,0.12,0,,0,0.001,0.732,0.06,0.001,0.204,12.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-29",8,7.08,239.82,,0.001,0.001,147.557,0.0591,0.011,0.0095,2484.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-01",2,0.91,21.01,,0,0.001,14.881,0.0595,0.003,0.017,249.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-02",15,14.03,650.75,,0.002,0.001,374.054,0.0591,0.027,0.0087,6294.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-07",9,7.55,240.13,,0.001,0.001,149.318,0.0596,0.011,0.0113,2511.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-12",6,4.22,130.7,,0,0.001,81.545,0.0595,0.007,0.0238,1370.463,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-14",9,8.13,352.21,,0.001,0.001,202.022,0.059,0.015,0.0103,3399.167,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-15",7,5.58,175.8,,0.001,0.001,110.134,0.0594,0.009,0.0246,1853.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-16",10,8.09,324,,0.001,0.001,189.034,0.059,0.014,0.0108,3183.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-19",11,9.72,424.54,,0.001,0.001,243.168,0.0594,0.018,0.0142,4090.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-20",12,11.3,476.48,,0.001,0.001,275.475,0.0592,0.02,0.0091,4636.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-21",9,8.1,321.1,,0.001,0.001,188.828,0.0592,0.014,0.0096,3176.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-22",19,18.05,774.3,,0.002,0.001,447.091,0.0592,0.031,0.0091,7522.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-30",19,17.13,694.2,,0.002,0.001,410.191,0.0592,0.029,0.0166,6905.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-03",8,6.3,244.36,,0.001,0.001,145.796,0.0595,0.011,0.0256,2452.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-18",20,18.11,708.8,,0.002,0.001,422.21,0.0593,0.03,0.0151,7103.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-19",18,16.09,631,,0.002,0.001,375.348,0.0593,0.027,0.0093,6316.167,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-27",8,7.04,274.16,,0.001,0.001,163.48,0.0593,0.012,0.0113,2751.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-07",8,7.65,283.66,,0.001,0.001,171.781,0.0591,0.013,0.0096,2889.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-08",9,8.6,339,,0.001,0.001,200.36,0.0591,0.015,0.0092,3371.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-09",24,24,1015,,0.003,0.001,590.1,0.0592,0.04,0.008,9928.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-10",23,22.68,886.96,,0.003,0.001,527.012,0.0592,0.036,0.0081,8868.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-11",6,5.82,173.9,,0.001,0.001,111.128,0.0595,0.008,0.0093,1870.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-13",2,1.31,31.59,,0,0.001,21.993,0.0595,0.003,0.0135,370.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-14",8,6.1,225.49,,0.001,0.001,136.03,0.0591,0.01,0.0314,2289.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-15",9,7.17,307.62,,0.001,0.001,178.046,0.0593,0.013,0.025,2995.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-28",6,4.67,184,,0.001,0.001,109.094,0.0593,0.008,0.0122,1836.699,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-04",3,2.04,39.38,,0,0.001,29.978,0.0597,0.003,0.0153,503.346,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-12",20,19.3,927.2,,0.003,0.001,530.9,0.0592,0.037,0.0099,8930.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-13",1,0.05,0,,0,0.001,0.315,0.06,0,0.042,5.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-28",4,3.48,95.08,,0,0.001,64.144,0.0598,0.006,0.013,1077.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-02-29",1,0.07,0,,0,0.001,0.427,0.059,0,0.041,7.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-01",2,1.34,32.4,,0,0.001,22.564,0.059,0.003,0.014,380.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-28",7,6.4,255.69,,0.001,0.001,154.275,0.0593,0.012,0.01,2595.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-17",13,12.63,394.08,,0.001,0.001,254.273,0.0595,0.018,0.009,4277.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-18",17,15.65,669.15,,0.002,0.001,399,0.0592,0.028,0.0094,6714.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-19",17,15.64,679.98,,0.002,0.001,403.036,0.0591,0.028,0.0094,6782.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-26",3,1.69,42.16,,0,0.001,28.872,0.0597,0.003,0.0173,485.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-16",7,6,190.6,,0.001,0.001,122.17,0.0593,0.008,0.0117,2053.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-24",11,10.27,454.92,,0.001,0.001,265.45,0.0593,0.019,0.0095,4467.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-27",8,6.36,262.56,,0.001,0.001,156.032,0.0591,0.012,0.0153,2627.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-28",5,3.78,143.8,,0,0.001,87.216,0.0594,0.007,0.0138,1467.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-29",8,6.15,239.21,,0.001,0.001,144.108,0.0591,0.011,0.0299,2425.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-30",7,5.92,164.29,,0.001,0.001,109.52,0.0594,0.008,0.0107,1840.858,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-07-31",4,2.5,81.75,,0,0.001,51.817,0.059,0.005,0.024,872.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-10",8,6.65,217.26,,0.001,0.001,136.827,0.0591,0.011,0.0129,2304.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-12",6,5.03,195.8,,0.001,0.001,117.859,0.0592,0.009,0.012,1984.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-13",7,5.66,151.58,,0.001,0.001,101.682,0.0594,0.008,0.03,1710.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-14",9,7.23,277.18,,0.001,0.001,167.027,0.0594,0.012,0.0171,2809.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-15",9,8,276.67,,0.001,0.001,171.363,0.0596,0.012,0.0224,2881.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-16",10,8.82,324.92,,0.001,0.001,199.09,0.0593,0.015,0.0157,3349.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-17",13,11.8,439.58,,0.001,0.001,267.844,0.0591,0.019,0.0095,4506.986,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-18",11,10.18,418.63,,0.001,0.001,249.339,0.0595,0.018,0.0091,4190.451,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-19",10,8.08,294,,0.001,0.001,180.921,0.0593,0.014,0.0137,3044.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-20",9,8.62,289.5,,0.001,0.001,181.979,0.0592,0.014,0.0091,3061.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-22",11,9.58,279.69,,0.001,0.001,182.92,0.0591,0.014,0.01,3080.519,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-24",11,9.1,392.16,,0.001,0.001,230.627,0.0591,0.017,0.0185,3881.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-03",12,10.1,409.14,,0.001,0.001,244.768,0.0593,0.018,0.0226,4118.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-04",11,9.18,362.98,,0.001,0.001,218.302,0.0591,0.016,0.0206,3674.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-05",7,5.65,198.87,,0.001,0.001,124.104,0.0593,0.01,0.0283,2087.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-06",10,9.5,384.44,,0.001,0.001,229.533,0.0592,0.017,0.009,3861.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-14",12,9.74,451.76,,0.001,0.001,258.974,0.0591,0.021,0.0319,4358.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-15",12,10.47,347.4,,0.001,0.001,215.227,0.0594,0.016,0.0122,3619.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-16",13,11.49,478.81,,0.001,0.001,278.251,0.0593,0.02,0.0196,4682.749,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-17",17,15.25,641.52,,0.002,0.001,372.105,0.0592,0.026,0.0129,6259.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-18",9,7.95,283.17,,0.001,0.001,171.201,0.059,0.013,0.0207,2882.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-20",8,6.8,200.52,,0.001,0.001,128.272,0.0593,0.01,0.0123,2157.757,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-21",12,10.67,446.25,,0.001,0.0009,261.179,0.0592,0.019,0.014,4395.574,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-22",6,5.74,209.5,,0.001,0.001,127.667,0.0593,0.01,0.0098,2147.597,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-23",9,7.77,218.34,,0.001,0.001,141.735,0.0592,0.011,0.0104,2387.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-24",8,6.64,239.16,,0.001,0.0009,144.578,0.0593,0.011,0.0175,2430.662,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-26",13,11.2,344.4,,0.001,0.001,216.716,0.0592,0.016,0.0173,3648.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-27",11,9.1,380,,0.001,0.0009,220.418,0.0594,0.016,0.0097,3708.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-28",17,15.48,666.75,,0.002,0.001,385.634,0.0593,0.027,0.0105,6488.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-29",14,13.07,553.46,,0.002,0.001,321.517,0.0594,0.023,0.0093,5408.671,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-09-30",14,12.58,452.08,,0.001,0.001,272.17,0.0592,0.02,0.0103,4580.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-01",15,13.99,604.48,,0.002,0.001,351.859,0.0593,0.025,0.0101,5918.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-02",9,7.9,358.25,,0.001,0.001,205.965,0.0593,0.015,0.0231,3464.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-04",11,9.57,395.19,,0.001,0.001,231.163,0.0592,0.017,0.0116,3891.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-05",14,13.69,605.53,,0.002,0.001,345.129,0.0591,0.025,0.0087,5807.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-06",16,15.48,683.56,,0.002,0.001,387.2,0.0593,0.027,0.0093,6519.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-07",21,19.69,794.2,,0.002,0.001,459.385,0.0592,0.032,0.0151,7732.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-08",24,24,1024,,0.003,0.001,583.9,0.0591,0.039,0.008,9827.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-09",19,17.69,763.78,,0.002,0.001,435.807,0.0594,0.031,0.0088,7330.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-10",10,8.27,279.5,,0.001,0.001,168.162,0.0593,0.012,0.0084,2829.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-11",9,7.15,228.35,,0.001,0.001,139.84,0.0594,0.011,0.0283,2351.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-12",19,18.38,742.08,,0.002,0.001,430.326,0.0593,0.03,0.0095,7240.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-13",23,22.08,973.08,,0.003,0.001,553.304,0.0593,0.037,0.0087,9310.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-14",14,13.12,614.32,,0.002,0.001,344.948,0.0591,0.024,0.0158,5801.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-15",24,24,1097,,0.003,0.001,619,0.0591,0.042,0.008,10419.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-16",24,24,1024,,0.003,0.001,586.6,0.059,0.039,0.008,9873.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-17",19,17.15,699.32,,0.002,0.001,404.931,0.0593,0.029,0.0152,6811.242,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-18",13,11.15,469.64,,0.001,0.001,270.655,0.0593,0.02,0.0206,4553.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-19",20,19.48,951.2,,0.003,0.001,531.952,0.0591,0.037,0.009,8955.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-20",24,24,1168,,0.003,0.001,653.8,0.0592,0.044,0.008,11001.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-21",24,24,1092,,0.003,0.001,621.4,0.0593,0.042,0.008,10455.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-22",5,5,147,,0,0.001,93.2,0.059,0.006,0.0082,1570.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-23",13,11.2,473.28,,0.001,0.001,272.424,0.0593,0.02,0.0195,4584.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-24",20,18.52,891.8,,0.003,0.001,501.55,0.0592,0.035,0.0109,8440.669,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-25",8,7,210.82,,0.001,0.001,134.02,0.0594,0.01,0.0163,2254.238,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-26",20,18.2,796.2,,0.002,0.001,460.872,0.0592,0.032,0.0149,7756.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-27",19,17.32,756.4,,0.002,0.001,439.086,0.0591,0.031,0.0142,7389.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-28",18,17.19,697.27,,0.002,0.001,411.275,0.0591,0.029,0.0088,6918.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-29",20,18.56,802.68,,0.002,0.001,464.748,0.0591,0.032,0.0099,7821.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-10-31",10,9.23,218.22,,0.001,0.001,150.437,0.0592,0.011,0.0125,2529.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-01",9,6.29,150.04,,0.001,0.001,103.697,0.0592,0.008,0.0227,1743.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-02",18,17.95,755.65,,0.002,0.001,442.12,0.0593,0.031,0.0086,7438.065,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-03",20,17.87,704.1,,0.002,0.001,417.354,0.0593,0.029,0.0118,7022.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-04",18,17.68,725.64,,0.002,0.001,424.776,0.0592,0.03,0.0087,7148.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-05",20,17.35,713.91,,0.002,0.001,417.192,0.0593,0.03,0.0162,7017.662,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-06",19,17.68,758.22,,0.002,0.001,435.84,0.0594,0.03,0.0094,7332.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-09",12,11,364.68,,0.001,0.001,224.28,0.0593,0.016,0.0101,3777.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-10",19,17.2,748.45,,0.002,0.001,432.145,0.0592,0.03,0.0157,7269.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-11",19,17.19,606.76,,0.002,0.001,368.143,0.0593,0.026,0.0159,6190.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-12",18,16.52,716.57,,0.002,0.001,412.687,0.0594,0.029,0.0111,6943.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-16",17,15.2,662.65,,0.002,0.0009,382.08,0.0594,0.027,0.0148,6428.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-17",18,16.65,716.44,,0.002,0.001,416.047,0.0593,0.029,0.0102,7001.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-23",18,16.34,683.76,,0.002,0.001,400.314,0.0593,0.028,0.0126,6733.237,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-24",20,18.05,751,,0.002,0.001,441.243,0.0594,0.031,0.0104,7422.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-25",19,18.63,672.38,,0.002,0.001,409.488,0.0592,0.029,0.0087,6892.258,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-26",24,24,852,,0.003,0.001,520.4,0.0592,0.035,0.008,8755.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-27",24,24,826,,0.003,0.001,507.4,0.0593,0.034,0.008,8537.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-28",24,24,822,,0.003,0.001,509.2,0.0592,0.034,0.008,8565.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-29",24,24,959,,0.003,0.001,570.7,0.0591,0.038,0.008,9602.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-11-30",24,24,946,,0.003,0.001,566.3,0.0592,0.038,0.008,9530.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-01",24,24,904,,0.003,0.001,541.8,0.0591,0.036,0.008,9120.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-02",24,24,827,,0.003,0.001,506.3,0.0592,0.034,0.008,8520.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-03",24,24,952,,0.003,0.001,565.3,0.0592,0.038,0.008,9510.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-04",24,24,858,,0.003,0.001,522.2,0.0593,0.035,0.008,8788.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-05",24,24,923,,0.003,0.001,550,0.0593,0.037,0.008,9252.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-06",24,24,1010,,0.003,0.001,588.4,0.0592,0.04,0.008,9905.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-07",24,24,900,,0.003,0.001,540.4,0.0593,0.036,0.008,9092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-08",24,23.05,912,,0.003,0.001,539.01,0.0593,0.036,0.0096,9068.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-10",9,8.2,307.2,,0.001,0.001,184.24,0.0591,0.014,0.0129,3101.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-11",24,24,849,,0.003,0.001,515.2,0.0593,0.034,0.008,8668.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-12",24,24,809,,0.003,0.001,498.5,0.0592,0.034,0.008,8387.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-13",24,24,814,,0.003,0.001,501.3,0.0593,0.034,0.008,8432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-14",24,24,819,,0.003,0.001,502.2,0.0595,0.034,0.008,8443.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-15",24,24,846,,0.003,0.001,516.1,0.0594,0.035,0.008,8680.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-16",23,22.05,757,,0.002,0.001,463.31,0.0592,0.031,0.0093,7795.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-17",19,18.07,682.42,,0.002,0.001,407.074,0.0593,0.028,0.0143,6850.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-18",21,18.17,700,,0.002,0.001,416.564,0.0591,0.029,0.0101,7014.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-19",8,6.15,253,,0.001,0.001,148.165,0.0591,0.011,0.025,2494.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-20",9,7.2,285.38,,0.001,0.001,169.358,0.0592,0.012,0.0187,2849.469,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-21",19,18.93,625.69,,0.002,0.001,387.879,0.0594,0.027,0.0084,6523.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-22",19,18.1,737.85,,0.002,0.001,434.424,0.0593,0.03,0.0088,7308.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-23",19,18.85,814.4,,0.002,0.001,472.255,0.0591,0.033,0.0085,7953.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-24",7,4.28,128.17,,0,0.001,82.085,0.0594,0.007,0.0287,1380.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-27",8,6.6,244.58,,0.001,0.001,147.313,0.0591,0.011,0.0116,2478.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-28",20,19.07,707.28,,0.002,0.001,424.99,0.0594,0.03,0.0147,7148.739,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-29",20,18.18,623,,0.002,0.001,382.264,0.0591,0.027,0.0148,6435.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-30",18,13.98,614.03,,0.002,0.001,354.362,0.0591,0.025,0.0114,5965.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"3",,"2020-12-31",6,4.63,128.42,,0,0.001,84.05,0.0592,0.007,0.028,1414.503,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-02",8,7.03,252,,0.001,0.001,151.389,0.0594,0.012,0.0173,2545.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-03",8,6.21,241.71,,0.001,0.001,141.937,0.0591,0.011,0.032,2388.499,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-06",5,4.01,126.03,,0,0.001,78.339,0.059,0.007,0.013,1320.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-07",9,7.09,283,,0.001,0.001,165.75,0.0593,0.013,0.0134,2787.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-09",18,17.1,829.12,,0.002,0.001,463.644,0.059,0.033,0.0094,7806.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-13",20,19.08,882.8,,0.003,0.001,498.316,0.0591,0.034,0.0152,8386.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-14",18,15.69,728.74,,0.002,0.001,411.578,0.0591,0.03,0.0129,6926.437,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-15",20,18.11,644.64,,0.002,0.001,387.23,0.0593,0.027,0.0202,6516.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-17",1,0.12,0,,0,0.001,0.768,0.06,0.002,0.235,12.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-20",5,4.12,138.68,,0,0.001,91.052,0.0594,0.008,0.0338,1532.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-21",12,11.57,396.54,,0.001,0.001,276.078,0.0595,0.019,0.0083,4644.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-23",3,2.45,65.9,,0,0.001,42.985,0.059,0.004,0.0157,723.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-24",1,0.42,8.4,,0,0.001,6.132,0.059,0.001,0.013,103.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-28",2,1.2,32,,0,0.001,21.22,0.0595,0.003,0.041,357.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-29",10,9.12,336.84,,0.001,0.001,200.592,0.059,0.013,0.0099,3376.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-04",15,13.14,221.63,,0.001,0.001,175.734,0.0593,0.013,0.023,2958.982,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-05",18,17.55,419.35,,0.001,0.001,285.46,0.059,0.02,0.0091,4808.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-06",20,17.67,555.55,,0.002,0.001,345.947,0.0595,0.025,0.0138,5819.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-07",19,17.3,823.15,,0.002,0.001,460.65,0.0593,0.033,0.014,7750.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-08",19,18.98,641.42,,0.002,0.001,391.736,0.0593,0.028,0.0085,6590.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-09",18,15.2,665.08,,0.002,0.0009,382.285,0.0592,0.027,0.0221,6432.488,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-10",19,18.03,848.4,,0.002,0.001,476.632,0.0591,0.034,0.012,8019.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-13",18,16.08,774.1,,0.002,0.001,432.836,0.0592,0.031,0.0215,7280.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-15",4,2.75,66.64,,0,0.001,45.556,0.0593,0.005,0.041,766.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-18",1,0.33,3.63,,0,0.001,3.564,0.06,0.002,0.058,59.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-22",4,3.58,95.02,,0,0.001,62.636,0.0593,0.005,0.0125,1053.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-23",1,0.17,1.7,,0,0.001,1.768,0.059,0,0.022,29.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-03",3,2.44,54.98,,0,0.001,38.443,0.0597,0.004,0.0133,646.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-18",2,0.11,0,,0,0.001,0.69,0.0595,0.001,0.25,11.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-03-31",5,3.35,95.8,,0,0.001,61.41,0.0596,0.005,0.029,1033.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-01",5,3.27,62,,0,0.0008,46.149,0.0592,0.005,0.0412,777.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-08",4,2.11,42.8,,0,0.001,30.494,0.0593,0.003,0.0698,513.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-15",4,2.05,60,,0,0.001,37.834,0.0593,0.005,0.0338,637.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-01",6,5.05,200.9,,0.001,0.001,117.206,0.0595,0.01,0.0118,1970.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-07",10,8.68,273.12,,0.001,0.001,170.274,0.0594,0.013,0.0164,2864.745,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-09",6,5.01,187.78,,0.001,0.001,110.96,0.0593,0.009,0.0117,1865.726,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-17",11,10.4,333.6,,0.001,0.001,206.04,0.0592,0.015,0.01,3466.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-18",24,24,743,,0.002,0.001,463.5,0.0593,0.03,0.0078,7797.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-19",10,9.15,239.5,,0.001,0.001,156.56,0.0591,0.011,0.0091,2638.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-24",10,8.5,274.64,,0.001,0.0009,171.2,0.0593,0.013,0.0183,2880.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-25",13,11.28,461.8,,0.001,0.001,268.694,0.0594,0.019,0.0147,4519.858,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-26",16,14.49,587.46,,0.002,0.0009,343.257,0.0593,0.024,0.0139,5776.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-27",13,11.35,353.25,,0.001,0.001,221.358,0.0592,0.016,0.0135,3725.417,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-28",11,10.01,457.22,,0.001,0.001,261.247,0.0592,0.018,0.0085,4397.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-29",8,6.15,230.3,,0.001,0.001,137.25,0.0594,0.011,0.0301,2308.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-01",13,12.31,578.23,,0.002,0.001,324.495,0.0592,0.024,0.0091,5460.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-02",17,15.25,611.85,,0.002,0.001,356.07,0.0593,0.025,0.0168,5990.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-03",12,10.18,321.25,,0.001,0.001,198.743,0.0593,0.015,0.019,3342.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-04",18,16.55,740.36,,0.002,0.001,417.709,0.0592,0.029,0.0103,7030.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-05",10,9.03,218.78,,0.001,0.001,147.272,0.059,0.011,0.0118,2482.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-08",6,5.08,160.66,,0.001,0.001,100.164,0.0597,0.009,0.037,1684.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-09",16,14.25,527.97,,0.002,0.001,314.073,0.0592,0.023,0.0143,5286.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-10",13,12.18,542.8,,0.002,0.001,308.09,0.0593,0.022,0.0094,5184.652,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-11",11,9.2,396,,0.001,0.001,226.94,0.0592,0.017,0.022,3818.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-12",3,2.38,66.11,,0,0.001,42.937,0.0593,0.005,0.0177,722.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-15",15,14.02,547.6,,0.002,0.001,320.64,0.0591,0.023,0.0189,5397.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-16",17,15.48,717.12,,0.002,0.001,404.768,0.0593,0.029,0.0106,6810.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-17",9,7.63,302.14,,0.001,0.001,177.247,0.0593,0.013,0.0123,2981.091,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-18",8,7.07,318,,0.001,0.001,181.427,0.0595,0.014,0.016,3050.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-20",9,7.55,301.9,,0.001,0.001,176.085,0.0592,0.013,0.0258,2963.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-21",8,7.65,351.12,,0.001,0.001,198.631,0.0594,0.015,0.0095,3340.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-22",10,9.03,422.29,,0.001,0.001,238.277,0.0593,0.017,0.0103,4008.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-23",12,10.18,430.2,,0.001,0.001,247.348,0.0592,0.017,0.0148,4162.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-24",9,8.35,378.98,,0.001,0.001,215.5,0.0591,0.016,0.0108,3627.071,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-25",11,9.74,391.8,,0.001,0.001,227.414,0.0593,0.017,0.0082,3826.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-26",10,8.49,386.28,,0.001,0.001,217.646,0.0593,0.017,0.0118,3662.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-27",13,11.4,543.3,,0.002,0.001,303.9,0.0592,0.022,0.0125,5113.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-29",9,7.26,267.08,,0.001,0.001,158.605,0.0592,0.012,0.0243,2670.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-06-30",8,6.91,289.39,,0.001,0.001,165.716,0.0593,0.013,0.0116,2788.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-01",9,8.42,379.22,,0.001,0.001,214.338,0.0592,0.015,0.0082,3607.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-02",8,6.2,285.6,,0.001,0.001,160.94,0.059,0.012,0.0268,2708.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-03",6,4.12,171.3,,0.001,0.0008,99.28,0.0593,0.008,0.0192,1673.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-05",8,6.2,264.24,,0.001,0.0009,151.626,0.0591,0.012,0.027,2552.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-06",6,5.02,192.14,,0.001,0.001,113.65,0.0592,0.01,0.0438,1911.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-08",8,6.75,286.8,,0.001,0.001,165.481,0.0593,0.013,0.0283,2785.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-09",10,8.23,337.58,,0.001,0.001,195.994,0.0594,0.015,0.0253,3296.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-10",13,11.21,541.18,,0.002,0.001,302.07,0.059,0.022,0.0235,5085.369,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-11",10,8.6,378.85,,0.001,0.001,215.555,0.0591,0.016,0.017,3628.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-12",9,8.2,333.8,,0.001,0.001,192.6,0.0592,0.014,0.0103,3241.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-13",11,9.67,415.02,,0.001,0.001,236.141,0.0593,0.017,0.02,3972.922,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-14",9,8.55,357,,0.001,0.001,205.615,0.0591,0.015,0.0093,3462.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-15",8,7.6,280.5,,0.001,0.001,166.51,0.059,0.013,0.0094,2803.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-16",11,10.15,342.68,,0.001,0.001,209.097,0.0593,0.016,0.0095,3517.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-17",6,5.08,171.53,,0.001,0.001,104.611,0.059,0.009,0.011,1761.837,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-18",8,7.09,283.85,,0.001,0.001,165.48,0.0591,0.013,0.011,2783.887,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-19",6,4.16,158.91,,0,0.001,93.482,0.0593,0.008,0.0328,1572.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-20",10,9.07,392.7,,0.001,0.001,224.357,0.0593,0.017,0.0098,3774.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-21",4,3.16,70.48,,0,0.001,48.96,0.0593,0.005,0.0125,825.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-22",10,9.05,345.15,,0.001,0.001,203.719,0.0591,0.014,0.0095,3429.769,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-23",10,9,326.2,,0.001,0.001,194.75,0.0594,0.015,0.0096,3276.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-24",8,6.47,214.01,,0.001,0.001,131.287,0.0594,0.011,0.0308,2207.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-25",9,7.18,279.05,,0.001,0.001,163.309,0.0591,0.013,0.0193,2749.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-26",11,9.39,443.01,,0.001,0.001,248.256,0.0592,0.018,0.0233,4174.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-27",12,10.53,359.43,,0.001,0.001,217.54,0.0593,0.016,0.0125,3658.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-28",13,11.15,536.35,,0.002,0.001,299.62,0.0592,0.022,0.0208,5041.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-29",12,10.72,497.75,,0.001,0.001,279.824,0.0593,0.02,0.0172,4709.271,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-30",13,11.43,506.68,,0.001,0.001,288.371,0.0592,0.021,0.0126,4852.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-07-31",9,8.27,301.33,,0.001,0.001,179.723,0.0592,0.014,0.0098,3024.327,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-01",8,6.13,198.1,,0.001,0.001,121.946,0.0593,0.01,0.0359,2054.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-02",10,8.2,376.3,,0.001,0.001,211.37,0.0593,0.016,0.0247,3556.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-03",12,10.13,451.28,,0.001,0.001,256.105,0.0594,0.019,0.0243,4308.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-04",12,10.18,435.3,,0.001,0.001,248.818,0.0593,0.018,0.0216,4186.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-05",12,10.18,459.9,,0.001,0.001,259.226,0.0593,0.019,0.0228,4362.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-06",10,8.54,382.93,,0.001,0.001,216.407,0.0591,0.016,0.0147,3640.383,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-07",10,8.13,375.13,,0.001,0.001,210.374,0.0593,0.015,0.0247,3540.419,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-08",10,8.68,388.28,,0.001,0.001,219.256,0.0592,0.016,0.0126,3690.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-09",9,7.13,313.08,,0.001,0.0009,178.249,0.0592,0.013,0.0252,3000.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-10",13,12.05,566.12,,0.002,0.001,316.519,0.0592,0.023,0.0109,5325.615,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-11",11,10.28,434.44,,0.001,0.001,248.64,0.0595,0.018,0.0095,4182.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-12",13,11.61,526.54,,0.001,0.001,296.404,0.0592,0.021,0.0117,4990.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-13",11,9.7,369.08,,0.001,0.001,216.864,0.059,0.016,0.0189,3652.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-14",12,10.73,340.51,,0.001,0.001,208.757,0.0593,0.015,0.0099,3513.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-15",16,14.18,468.08,,0.001,0.001,284.369,0.0593,0.02,0.0148,4785.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-16",16,15.23,520.6,,0.002,0.001,314.389,0.0592,0.022,0.0106,5291.977,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-17",24,24,832,,0.003,0.001,503.1,0.0593,0.034,0.008,8468.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-18",24,24,1023,,0.003,0.001,587.4,0.0592,0.04,0.0081,9887.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-19",24,24,919,,0.003,0.001,543.6,0.0593,0.037,0.008,9143.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-20",22,21.55,655.7,,0.002,0.001,412.91,0.0591,0.028,0.0081,6948.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-21",17,16.1,498.1,,0.002,0.001,311.552,0.0594,0.022,0.0094,5241.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-22",16,15.25,520.08,,0.002,0.001,317.082,0.0593,0.023,0.0089,5336.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-23",14,12.21,463.8,,0.001,0.0009,274.774,0.0592,0.02,0.0124,4624.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-24",17,16.1,584.84,,0.002,0.001,351.87,0.0593,0.026,0.0092,5919.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-25",14,11.62,458.68,,0.001,0.0009,266.282,0.0592,0.021,0.0219,4479.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-26",13,11.34,401.44,,0.001,0.001,238.984,0.0592,0.017,0.0136,4025.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-27",12,10.13,361.9,,0.001,0.001,215.233,0.0593,0.016,0.0243,3621.579,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-28",15,14,484.95,,0.001,0.001,290.855,0.0593,0.021,0.0114,4892.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-29",16,14.12,489.05,,0.001,0.001,294.012,0.0593,0.021,0.0184,4948.185,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-30",13,12.02,379.19,,0.001,0.001,234.177,0.0592,0.017,0.0114,3939.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-08-31",14,13.02,466.9,,0.001,0.001,278.072,0.0591,0.02,0.0109,4678.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-01",15,13.87,448.78,,0.001,0.001,276.271,0.0593,0.02,0.0103,4649.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-02",14,12.23,400,,0.001,0.001,244.19,0.0592,0.018,0.0139,4110.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-03",18,16.15,558.63,,0.002,0.001,337.291,0.0591,0.024,0.0183,5676.734,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-04",16,15.13,594.16,,0.002,0.001,346.754,0.0591,0.025,0.0097,5836.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-05",17,17,647,,0.002,0.001,380.3,0.0592,0.027,0.0085,6399.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-06",24,24,979,,0.003,0.001,567.5,0.0591,0.038,0.008,9548.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-07",24,24,852,,0.003,0.001,511.3,0.0592,0.034,0.008,8606.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-08",22,21.08,775.08,,0.002,0.001,460.804,0.0592,0.031,0.0092,7752.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-09",14,12.18,329.48,,0.001,0.001,215.45,0.0595,0.016,0.0226,3623.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-10",11,9.35,278.1,,0.001,0.001,177.705,0.0593,0.013,0.0197,2991.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-11",11,9.38,343.55,,0.001,0.001,206.722,0.0593,0.016,0.0196,3477.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-12",11,9.12,289.05,,0.001,0.001,180.319,0.0595,0.013,0.0237,3030.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-13",9,7.72,237.7,,0.001,0.001,149.588,0.0592,0.012,0.011,2519.043,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-17",1,0.12,0,,0,0.001,0.72,0.06,0.001,0.222,12.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-21",7,5.85,221.72,,0.001,0.001,132.599,0.0591,0.009,0.0094,2232.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-28",12,11.02,436.65,,0.001,0.001,257.259,0.0593,0.019,0.0127,4328.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-29",12,11.47,489.98,,0.001,0.001,282.229,0.0593,0.021,0.009,4749.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-09-30",9,7.32,267.6,,0.001,0.001,159.712,0.0591,0.012,0.0158,2687.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-01",11,10.18,431.94,,0.001,0.001,251.456,0.0593,0.018,0.0096,4230.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-03",9,7.85,328.34,,0.001,0.001,192.135,0.0594,0.013,0.0087,3230.343,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-04",6,5.24,221.28,,0.001,0.001,128.56,0.0595,0.01,0.0103,2160.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-05",9,8.34,340.34,,0.001,0.001,197.347,0.0594,0.015,0.0106,3317.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-06",12,10.15,411.64,,0.001,0.001,237.379,0.0593,0.017,0.0235,3992.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-07",12,10.7,440.64,,0.001,0.001,252.712,0.0594,0.019,0.0124,4249.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-08",9,7.1,256.1,,0.001,0.001,152.24,0.0593,0.012,0.0308,2562.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-09",9,7.82,299.84,,0.001,0.001,175.022,0.0596,0.012,0.0114,2944.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-12",13,11.17,506,,0.001,0.001,283.877,0.0593,0.021,0.0237,4777.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-13",13,12.07,540.56,,0.002,0.001,304.651,0.0593,0.022,0.0207,5122.611,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-14",23,22.58,973.34,,0.003,0.001,553.006,0.0593,0.037,0.0081,9302.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-15",15,13.05,570,,0.002,0.001,322.699,0.0592,0.023,0.0137,5432.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-16",14,12.14,542.56,,0.002,0.001,305.785,0.0592,0.022,0.0226,5143.698,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-17",11,9.76,405.06,,0.001,0.001,231.106,0.0591,0.017,0.0161,3890.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-18",9,7.61,281.78,,0.001,0.001,166.325,0.0591,0.012,0.0103,2799.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-19",19,18.08,791.8,,0.002,0.001,451.332,0.0592,0.032,0.0156,7594.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-20",20,17.24,793.8,,0.002,0.001,446.439,0.0592,0.032,0.0191,7511.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-21",20,18.23,877.83,,0.002,0.001,490.478,0.0593,0.035,0.0156,8250.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-22",20,19.2,949.2,,0.003,0.001,525.54,0.0593,0.037,0.0105,8839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-23",21,20.03,881,,0.003,0.001,498.083,0.059,0.034,0.0124,8385.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-27",6,4.93,203.02,,0.001,0.001,118.283,0.059,0.01,0.0122,1991.419,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-29",7,5.55,179.92,,0.001,0.001,111.593,0.059,0.009,0.0144,1880.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-02",5,4.11,151.52,,0,0.001,90.602,0.0594,0.008,0.0132,1525.007,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-05",7,5.18,177.35,,0.001,0.001,107.436,0.0591,0.009,0.0354,1808.663,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-13",16,15.48,612.46,,0.002,0.001,358.834,0.0594,0.026,0.0088,6034.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-18",7,5.17,177,,0.001,0.001,108.358,0.0597,0.009,0.0349,1821.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-19",1,0.88,23.76,,0,0.001,15.576,0.059,0.002,0.018,262.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-20",19,17.12,689.1,,0.002,0.0009,404.202,0.0591,0.029,0.0122,6806.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-25",11,9.63,308.6,,0.001,0.001,192.429,0.0593,0.014,0.0176,3238.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-26",6,4.67,152.4,,0,0.001,95.091,0.0597,0.008,0.0262,1598.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-28",9,7.17,285.8,,0.001,0.001,168.644,0.0592,0.013,0.0287,2836.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-29",9,8.13,328.33,,0.001,0.001,193.384,0.0592,0.015,0.0103,3255.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-11-30",9,7.14,292.92,,0.001,0.0009,172,0.0596,0.013,0.0323,2894.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-01",9,8.19,301.23,,0.001,0.001,180.34,0.0591,0.014,0.0108,3036.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-02",19,18.05,811.3,,0.002,0.001,461.609,0.0592,0.033,0.0106,7770.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-03",19,17.15,825.48,,0.002,0.001,464.452,0.0594,0.033,0.0149,7811.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-04",19,17.63,841.44,,0.002,0.001,473.477,0.0592,0.034,0.0129,7968.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-05",7,6.01,282.48,,0.001,0.001,159.199,0.0591,0.013,0.017,2678.825,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-07",19,18.88,894.4,,0.003,0.001,504.632,0.0592,0.036,0.0086,8489.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-08",21,19.09,778.49,,0.002,0.001,453.884,0.0592,0.032,0.0214,7637.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-09",20,18.15,757.46,,0.002,0.001,437.577,0.0592,0.032,0.0128,7366.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-10",20,18.2,696.8,,0.002,0.001,412.272,0.0593,0.029,0.0164,6935.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-11",19,18.33,865.1,,0.002,0.001,486.518,0.0592,0.034,0.0098,8184.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-12",10,8.2,315.3,,0.001,0.001,186.39,0.059,0.014,0.0246,3138.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-13",11,9.65,345.8,,0.001,0.001,208.795,0.0593,0.016,0.0136,3513.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-14",19,18.08,807.12,,0.002,0.001,460.468,0.0593,0.032,0.0152,7746.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-15",24,24,1166,,0.003,0.001,652,0.059,0.044,0.008,10974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-16",10,7.35,298.44,,0.001,0.001,174.227,0.0594,0.013,0.0287,2930.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-21",16,15.53,410.32,,0.001,0.001,271.816,0.0594,0.02,0.0089,4573.871,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-22",7,5.94,216.06,,0.001,0.001,130.116,0.0591,0.009,0.0149,2190.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-23",9,7.21,246.65,,0.001,0.001,150.84,0.0596,0.012,0.0261,2537.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-29",7,5.18,151.1,,0,0.001,96.514,0.0591,0.008,0.0344,1625.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-30",5,3.57,140.38,,0,0.001,82.189,0.0596,0.007,0.0194,1381.289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Almond Power Plant",7315,"4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-09",8,7.93,353.81,,0.001,0.001,168.716,0.0591,0.03,0.0329,2839.061,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-10",8,7.61,339.09,,0.001,0.001,161.611,0.0594,0.024,0.0223,2718.317,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-11",9,8.78,404.3,,0.001,0.001,191.198,0.0593,0.025,0.0206,3217.383,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-22",8,7.08,300.94,,0.001,0.001,145.282,0.0591,0.025,0.0341,2444.921,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-23",7,6.82,301.41,,0.001,0.001,144.215,0.0593,0.021,0.0224,2428.363,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-29",7,6.26,255.85,,0.001,0.001,124.21,0.0594,0.024,0.0347,2089.301,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-10",7,5.9,251.84,,0.001,0.001,120.909,0.0594,0.025,0.0424,2033.981,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-11",1,0.37,0,,0,0.001,0.555,0.061,0,0.06,9.102,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-12",7,5.84,251.76,,0.001,0.001,120.316,0.0591,0.022,0.0493,2024.477,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-13",7,5.2,223,,0.001,0.001,107.264,0.059,0.017,0.0257,1807.244,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-27",8,7.13,309.13,,0.001,0.001,147.712,0.0594,0.027,0.0344,2484.687,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-28",6,5.62,247.66,,0.001,0.001,117.699,0.0595,0.017,0.03,1978.554,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-29",7,6.68,292.68,,0.001,0.001,140.364,0.0593,0.02,0.0264,2360.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-30",13,11.89,567.72,,0.001,0.001,267.355,0.0593,0.031,0.0235,4499.498,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-07-31",8,6.67,298.19,,0.001,0.001,140.91,0.0591,0.018,0.0301,2371.119,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-01",7,6.23,271.31,,0.001,0.001,129.698,0.0594,0.016,0.0306,2180.639,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-03",6,5.08,210.63,,0.001,0.001,101.38,0.0593,0.016,0.031,1704.245,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-10",7,5.9,250.25,,0.001,0.001,119.77,0.0593,0.022,0.0391,2014.395,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-11",6,5.38,235.45,,0.001,0.001,111.594,0.0593,0.015,0.0263,1876.897,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-12",8,7.13,325.29,,0.001,0.001,153.592,0.0595,0.018,0.0219,2582.297,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-13",13,12.37,583.18,,0.001,0.001,273.795,0.0591,0.026,0.0155,4607.583,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-14",14,13.68,649.2,,0.002,0.001,304.4,0.0593,0.028,0.0158,5123.104,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-15",18,17.16,814.88,,0.002,0.001,380.048,0.0592,0.033,0.0138,6396.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-16",17,15.47,723.86,,0.002,0.001,339.328,0.0594,0.028,0.0148,5708.72,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-17",15,14.95,706,,0.002,0.001,332.595,0.0593,0.024,0.0103,5597.08,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-18",18,17.12,811,,0.002,0.001,380.516,0.0593,0.032,0.0123,6403.424,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-19",14,13.25,612.51,,0.001,0.001,287.853,0.0591,0.028,0.0136,4844.059,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-20",11,10.65,488.35,,0.001,0.001,229.625,0.0593,0.024,0.0153,3865.44,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-21",10,7.91,296.11,,0.001,0.001,144.956,0.0591,0.021,0.0327,2441.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-22",7,6.15,267.35,,0.001,0.001,126.735,0.059,0.015,0.0226,2133.055,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-23",10,9.5,434.23,,0.001,0.001,203.788,0.0592,0.023,0.0184,3428.943,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-24",8,7.38,326.65,,0.001,0.001,153.119,0.0593,0.017,0.0204,2576.843,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-25",7,6.1,256.41,,0.001,0.001,122.766,0.0594,0.015,0.0236,2065.612,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-26",8,5.86,218.01,,0.001,0.0009,106.021,0.0591,0.02,0.0356,1785.644,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-27",18,17.1,819.36,,0.002,0.001,382.186,0.0592,0.033,0.0158,6432.582,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-28",9,8.37,373.18,,0.001,0.001,176.67,0.0596,0.018,0.0173,2971.072,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-29",11,10.1,456.69,,0.001,0.001,215.834,0.0595,0.022,0.0174,3631.01,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-30",10,9.11,408.73,,0.001,0.001,193.063,0.0591,0.021,0.0189,3250.603,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-08-31",11,10.1,461.61,,0.001,0.001,218.793,0.0591,0.023,0.0171,3682.356,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-01",9,8.12,361.97,,0.001,0.001,172.474,0.0592,0.02,0.0198,2901.224,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-02",7,6.62,288.42,,0.001,0.001,137.04,0.0596,0.016,0.0221,2303.962,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-03",13,12.72,598.52,,0.001,0.001,281.304,0.0593,0.024,0.0151,4733.544,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-04",24,24,1198,,0.003,0.001,554.1,0.0593,0.037,0.0078,9323.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-05",17,16.38,775.54,,0.002,0.001,366.18,0.0593,0.03,0.0111,6161.158,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-06",16,15.83,742.81,,0.002,0.001,352.006,0.0591,0.025,0.0098,5925.676,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-07",14,12.85,548.14,,0.001,0.001,265.177,0.0591,0.023,0.0139,4465.298,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-08",10,7.73,317.06,,0.001,0.001,153.155,0.0594,0.022,0.0229,2575.439,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-09",10,9.12,420.72,,0.001,0.001,200.759,0.0591,0.019,0.0158,3380.383,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-10",6,5.1,214.34,,0.001,0.001,103.841,0.0593,0.016,0.027,1746.514,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-14",7,5.9,247.35,,0.001,0.001,119.1,0.0593,0.019,0.0393,2003.625,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-15",6,5.32,217.52,,0.001,0.001,106.767,0.0592,0.015,0.0208,1796.66,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-17",1,0.43,0,,0,0.001,1.032,0.06,0.001,0.095,17.243,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-19",6,5.62,234.18,,0.001,0.001,112.918,0.0595,0.019,0.026,1898.388,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-21",7,5.62,230.84,,0.001,0.001,112.122,0.0593,0.023,0.0369,1887.765,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-23",6,5.41,219.71,,0.001,0.001,107.493,0.0593,0.016,0.0272,1808.965,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-28",10,9.38,424.78,,0.001,0.001,201.2,0.0592,0.027,0.0211,3387.302,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-29",12,11.62,539.29,,0.001,0.001,254.962,0.0593,0.024,0.016,4288.334,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-09-30",12,10.02,438.25,,0.001,0.001,208.813,0.0596,0.021,0.0264,3510.283,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-01",11,10.37,480.43,,0.001,0.001,229.892,0.0594,0.021,0.0149,3865.169,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-02",11,10.38,479.16,,0.001,0.001,229.28,0.0594,0.022,0.0134,3857.03,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-03",6,5.37,222.84,,0.001,0.001,108.209,0.0592,0.014,0.0202,1822.539,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-04",6,5.32,228.84,,0.001,0.001,110.42,0.0592,0.016,0.0223,1858.127,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-05",8,6.85,298.41,,0.001,0.001,142.621,0.0594,0.016,0.0259,2398.977,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-06",8,7.12,315.17,,0.001,0.001,147.641,0.059,0.018,0.029,2487.214,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-07",7,5.87,255.81,,0.001,0.001,120.385,0.0593,0.018,0.0319,2026.919,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-11",12,10.17,426.91,,0.001,0.001,202.604,0.0591,0.031,0.0263,3412.273,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-12",16,13.4,568.07,,0.001,0.001,269.712,0.0591,0.033,0.0249,4540.03,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-13",19,16.99,779.34,,0.002,0.001,364.121,0.0592,0.033,0.0188,6131.598,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-14",5,4.3,180.4,,0,0.001,86.15,0.0592,0.015,0.0292,1449.905,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-15",20,19.37,918.73,,0.002,0.001,428.302,0.0592,0.04,0.0129,7204.735,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-16",20,19.15,915.05,,0.002,0.001,431.965,0.0594,0.036,0.011,7267.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-20",9,6.95,297.15,,0.001,0.001,141.959,0.0592,0.021,0.0452,2388.346,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-21",7,6.37,282.68,,0.001,0.001,134.67,0.0594,0.017,0.0246,2264.508,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-22",7,6.12,266.97,,0.001,0.001,126.548,0.059,0.018,0.0264,2131.69,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-26",14,10.24,388.88,,0.001,0.001,191.656,0.0594,0.042,0.0317,3226.408,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-27",14,13,564.82,,0.001,0.001,270.564,0.0593,0.031,0.0181,4550.234,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-28",6,4.66,191.94,,0,0.0008,92.902,0.0595,0.015,0.0192,1563.88,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-02",8,7.12,300.92,,0.001,0.001,144.428,0.0595,0.021,0.0321,2428.808,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-03",9,8.37,366.1,,0.001,0.001,173.813,0.059,0.02,0.0161,2927.87,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-04",9,8.75,393.75,,0.001,0.001,185.475,0.0591,0.019,0.0194,3120.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-05",14,12.75,568.33,,0.001,0.001,267.281,0.0592,0.023,0.0136,4497.617,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-16",6,5.87,246.67,,0.001,0.001,118.252,0.0593,0.02,0.0287,1990.478,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-01",11,10.02,431.7,,0.001,0.001,206.672,0.0593,0.027,0.0235,3479.285,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-15",10,9.25,419.5,,0.001,0.001,198.975,0.0592,0.025,0.0275,3349.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-16",11,10.18,467.44,,0.001,0.001,219.142,0.0591,0.022,0.0161,3689.153,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-17",2,1.37,60.84,,0,0.001,28.572,0.0595,0.002,0.0085,480.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","NCPA Combustion Turbine Project #2",7449,"NA1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-01",24,24,787,,0.002,0.001,470,0.058,0.026,0.0065,8062.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-02",24,24,887,,0.003,0.001,501.8,0.058,0.029,0.0068,8609.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-03",24,24,1032,,0.003,0.001,549.3,0.058,0.032,0.0067,9424.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-04",24,24,823,,0.002,0.001,480.2,0.058,0.025,0.006,8242.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-05",24,24,970,,0.003,0.001,535.1,0.058,0.026,0.0057,9179.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-06",24,24,858,,0.003,0.001,496.6,0.058,0.027,0.0063,8519.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-07",24,24,858,,0.003,0.001,496.8,0.058,0.028,0.0066,8523.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-08",24,24,846,,0.003,0.001,491,0.058,0.029,0.0069,8422.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-09",24,24,968,,0.003,0.001,532.6,0.058,0.031,0.0068,9142.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-10",24,24,1057,,0.003,0.001,557.5,0.058,0.029,0.006,9564.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-11",24,24,801,,0.002,0.001,477.7,0.058,0.023,0.0055,8195.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-12",24,24,803,,0.002,0.001,480.3,0.058,0.026,0.0063,8238.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-13",24,24,874,,0.003,0.001,501.8,0.058,0.026,0.006,8609.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-14",24,24,846,,0.003,0.001,495.5,0.058,0.022,0.0053,8503.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-15",24,24,947,,0.003,0.001,526.1,0.058,0.03,0.0067,9025.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-16",24,24,1020,,0.003,0.001,548.9,0.058,0.031,0.0065,9418.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-17",24,24,978,,0.003,0.001,538.5,0.058,0.028,0.006,9244.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-18",24,24,924,,0.003,0.001,520,0.058,0.027,0.0062,8920,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-19",24,24,1045,,0.003,0.001,553,0.058,0.031,0.0065,9483,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-20",24,24,1190,,0.003,0.001,601,0.058,0.038,0.0074,10313.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-21",24,24,1063,,0.003,0.001,564.5,0.058,0.034,0.007,9684.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-22",24,24,1058,,0.003,0.001,556,0.0582,0.032,0.0067,9514.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-23",24,24,995,,0.003,0.001,535.1,0.058,0.029,0.0064,9185.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-24",16,15.67,667.11,,0.002,0.001,352.127,0.058,0.02,0.0068,6041,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-25",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-26",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-27",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-28",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-29",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-30",3,1.85,11.48,,0,0.001,14.379,0.058,0.012,0.131,247.237,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-01-31",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-01",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-02",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-03",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-04",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-05",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-06",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-07",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-08",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-09",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-10",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-11",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-12",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-13",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-14",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-15",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-16",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-17",18,17.85,724.25,,0.002,0.001,371.79,0.0588,0.023,0.0086,6275.745,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-18",24,24,1069,,0.003,0.001,550.8,0.0594,0.032,0.007,9206.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-19",24,24,1055,,0.003,0.001,520,0.058,0.031,0.007,8918.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-20",24,24,1030,,0.003,0.001,504.5,0.058,0.029,0.0067,8654.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-21",12,11.63,411.27,,0.001,0.001,210.402,0.058,0.012,0.0068,3607.661,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-22",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-23",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-24",12,10.14,424.36,,0.001,0.001,211.992,0.0582,0.015,0.0084,3636.924,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-25",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-26",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-27",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-28",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-02-29",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-01",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-02",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-03",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-04",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-05",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-06",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-07",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-08",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-09",15,14.65,561.15,,0.002,0.001,324.905,0.0627,0.02,0.0103,5146.095,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-10",24,24,1040,,0.003,0.001,551.1,0.0616,0.029,0.0064,8923,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-11",24,24,969,,0.002,0.001,474.7,0.058,0.027,0.0066,8147.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-12",24,24,1064,,0.003,0.001,509.9,0.058,0.027,0.006,8752.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-13",24,24,1068,,0.003,0.001,517.6,0.058,0.028,0.0063,8881.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-14",24,24,1157,,0.003,0.001,553.1,0.058,0.032,0.0067,9492.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-15",24,24,1156,,0.003,0.001,544.6,0.058,0.033,0.007,9347.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-16",24,24,1137,,0.003,0.001,609.7,0.0627,0.033,0.0069,9724.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-17",24,24,917,,0.003,0.001,556,0.0657,0.028,0.0066,8488.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-18",21,20.18,722.34,,0.002,0.001,435.286,0.0641,0.024,0.0093,6742.778,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-19",24,24,849,,0.003,0.001,500.9,0.0643,0.023,0.006,7808.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-20",24,24,838,,0.003,0.001,508.2,0.0655,0.028,0.0073,7778.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-21",24,24,936,,0.003,0.001,543.7,0.0644,0.027,0.0065,8438.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-22",24,24,880,,0.003,0.001,527.5,0.0648,0.025,0.0063,8143.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-23",24,24,857,,0.003,0.001,517,0.0645,0.027,0.0066,8030.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-24",24,24,897,,0.003,0.001,525.4,0.064,0.024,0.0059,8195.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-25",24,24,846,,0.003,0.001,500.9,0.0643,0.024,0.0062,7797.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-26",24,24,893,,0.003,0.001,518.7,0.0639,0.024,0.006,8114.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-27",24,24,889,,0.003,0.001,520.2,0.064,0.027,0.0066,8137.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-28",24,24,1061,,0.003,0.001,582.7,0.0633,0.029,0.0063,9209.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-29",24,24,927,,0.003,0.001,540.8,0.0639,0.026,0.0061,8463.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-30",24,24,886,,0.003,0.001,524.9,0.0643,0.026,0.0064,8177,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-03-31",24,24,874,,0.003,0.001,520.1,0.0645,0.026,0.0065,8074.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-01",24,24,888,,0.003,0.001,521.2,0.0643,0.026,0.0064,8106.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-02",24,24,958,,0.003,0.001,545.8,0.0638,0.027,0.0064,8562.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-03",24,24,930,,0.003,0.001,529.6,0.0637,0.026,0.0064,8315.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-04",24,24,976,,0.003,0.001,549.6,0.0642,0.024,0.0055,8591.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-05",24,24,1052,,0.003,0.001,584.4,0.064,0.024,0.0052,9147.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-06",24,24,1011,,0.003,0.001,576.6,0.0647,0.023,0.0052,8933.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-07",24,24,949,,0.003,0.001,564.2,0.0654,0.03,0.0068,8630.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-08",24,24,1048,,0.003,0.001,597.7,0.0647,0.029,0.0062,9255.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-09",24,24,1157,,0.003,0.001,636.1,0.064,0.034,0.0067,9964,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-10",24,24,943,,0.003,0.001,553.9,0.0649,0.026,0.006,8551.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-11",21,19.19,640.24,,0.002,0.001,388.676,0.0638,0.02,0.0105,6019.33,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-12",24,24,981,,0.003,0.001,561.6,0.0643,0.029,0.0067,8726.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-13",21,19.3,645.62,,0.002,0.001,396.174,0.064,0.021,0.0107,6113.905,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-14",24,24,1019,,0.003,0.001,573.8,0.0642,0.032,0.007,8952.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-15",24,24,962,,0.003,0.001,553.1,0.0643,0.029,0.0067,8612.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-16",24,24,948,,0.003,0.001,546.4,0.0645,0.026,0.006,8482.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-17",24,24,841,,0.003,0.001,508.4,0.0649,0.028,0.0071,7818.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-18",22,21.25,763,,0.002,0.001,457.5,0.0647,0.024,0.007,7040.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-19",23,22.8,773.8,,0.002,0.001,469.06,0.0644,0.026,0.0074,7245.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-20",24,24,911,,0.003,0.001,532.3,0.0647,0.028,0.0069,8249.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-21",24,24,883,,0.003,0.001,521.2,0.0645,0.028,0.007,8086.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-22",24,24,952,,0.003,0.001,548.8,0.0642,0.027,0.0063,8575.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-23",24,24,849,,0.003,0.001,512.1,0.0646,0.027,0.0068,7948.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-24",24,24,847,,0.003,0.001,513.4,0.0647,0.028,0.0072,7949.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-25",24,24,887,,0.003,0.001,526.4,0.0643,0.022,0.0052,8190.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-26",24,24,860,,0.003,0.001,512.3,0.0641,0.028,0.007,7982.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-27",24,24,826,,0.003,0.001,499.9,0.0645,0.029,0.0075,7761.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-28",24,24,857,,0.003,0.001,515.6,0.0644,0.026,0.0065,8012.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-29",24,24,828,,0.003,0.001,504.5,0.0646,0.027,0.007,7817,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-04-30",24,24,819,,0.003,0.001,502.7,0.065,0.028,0.0073,7757.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-01",24,24,868,,0.003,0.001,517.5,0.0646,0.028,0.007,8021.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-02",24,24,848,,0.003,0.001,510.1,0.0645,0.029,0.0073,7913.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-03",24,24,857,,0.003,0.001,513.5,0.0646,0.03,0.0075,7955.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-04",24,24,897,,0.003,0.001,531.7,0.0645,0.03,0.0074,8256.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-05",24,24,843,,0.002,0.001,452.9,0.0601,0.025,0.0066,7513.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-06",24,24,868,,0.002,0.001,440.3,0.058,0.026,0.0068,7555.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-07",24,24,816,,0.002,0.001,420.7,0.058,0.024,0.0066,7210.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-08",24,24,821,,0.002,0.001,420.9,0.058,0.024,0.0068,7226.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-09",24,24,908,,0.002,0.001,455.7,0.058,0.025,0.0065,7814.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-10",24,24,802,,0.002,0.001,413.5,0.058,0.023,0.0066,7096.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-11",16,15.12,498.72,,0.001,0.001,257.652,0.058,0.015,0.0067,4422.588,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-12",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-13",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-14",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-15",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-16",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-17",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-18",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-19",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-20",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-21",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-22",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-23",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-24",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-25",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-26",14,13.2,602,,0.002,0.001,317.34,0.0581,0.023,0.0182,5441.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-27",24,24,1076,,0.003,0.001,551.9,0.058,0.032,0.0068,9466.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-28",24,24,853,,0.002,0.001,438.3,0.058,0.026,0.0069,7519.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-29",11,10.07,354.07,,0.001,0.001,180.394,0.0581,0.009,0.0067,3097.591,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-30",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-05-31",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-01",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-02",13,12.13,445.65,,0.001,0.001,230.001,0.058,0.015,0.0166,3948.634,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-03",24,24,1025,,0.003,0.001,516.4,0.058,0.028,0.0063,8856.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-04",24,24,979,,0.003,0.001,500.6,0.058,0.029,0.0068,8588.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-05",12,11.12,546.72,,0.001,0.001,273.852,0.0581,0.017,0.007,4698.444,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-06",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-07",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-08",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-09",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-10",14,13.55,596.5,,0.002,0.001,307.015,0.058,0.018,0.0096,5266.42,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-11",24,24,940,,0.002,0.001,467,0.058,0.024,0.006,8012.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-12",24,24,901,,0.002,0.001,453.2,0.058,0.025,0.0063,7773.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-13",24,24,878,,0.002,0.001,443.2,0.058,0.024,0.0063,7603.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-14",24,24,856,,0.002,0.001,433.7,0.058,0.023,0.0061,7443.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-15",24,24,863,,0.002,0.001,438,0.058,0.026,0.0068,7512.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-16",24,24,895,,0.002,0.001,451.3,0.058,0.027,0.0069,7739.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-17",24,24,859,,0.002,0.001,436.8,0.058,0.025,0.0067,7492.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-18",24,24,879,,0.002,0.001,443.7,0.058,0.024,0.0063,7614.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-19",1,0.13,0.91,,0,0.001,0.923,0.058,0,0.012,15.912,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-20",17,16.5,598,,0.002,0.001,305.45,0.058,0.021,0.0111,5239.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-21",24,24,879,,0.002,0.001,445,0.058,0.027,0.007,7628.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-22",24,24,902,,0.002,0.001,453,0.058,0.027,0.0069,7775.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-23",24,24,984,,0.003,0.001,491.5,0.058,0.028,0.0067,8432,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-24",24,24,975,,0.002,0.001,485.3,0.058,0.028,0.0068,8325,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-25",24,24,925,,0.002,0.001,464.8,0.058,0.026,0.0066,7975.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-26",24,24,987,,0.003,0.001,489.8,0.058,0.029,0.0068,8408.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-27",24,24,978,,0.002,0.001,482.3,0.058,0.025,0.006,8274.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-28",24,24,900,,0.002,0.001,449.7,0.058,0.025,0.0064,7717.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-29",24,24,889,,0.002,0.001,446.7,0.058,0.026,0.0068,7661.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-06-30",24,24,889,,0.002,0.001,446.3,0.058,0.026,0.0069,7657.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-01",24,24,910,,0.002,0.001,454.8,0.058,0.027,0.0069,7806.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-02",24,24,889,,0.002,0.001,446.5,0.058,0.026,0.0067,7659.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-03",24,24,944,,0.002,0.001,468,0.058,0.027,0.0067,8030.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-04",24,24,940,,0.002,0.001,471.5,0.058,0.026,0.0065,8093.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-05",24,24,957,,0.002,0.001,473,0.058,0.026,0.0065,8119.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-06",24,24,870,,0.002,0.001,441.4,0.058,0.025,0.0066,7568.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-07",24,24,864,,0.002,0.001,436.2,0.058,0.024,0.0065,7486.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-08",24,24,885,,0.002,0.001,478.5,0.0602,0.025,0.0065,7898.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-09",24,24,920,,0.003,0.001,495.8,0.0612,0.026,0.0064,8085.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-10",24,24,951,,0.002,0.001,473.4,0.058,0.028,0.0068,8124.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-11",24,24,1011,,0.003,0.001,513.8,0.058,0.031,0.0069,8815.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-12",24,24,943,,0.002,0.001,483,0.058,0.028,0.0069,8285.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-13",24,24,867,,0.002,0.001,443.5,0.058,0.026,0.0069,7609.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-14",24,24,847,,0.002,0.001,432.6,0.058,0.026,0.0071,7421.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-15",24,24,867,,0.002,0.001,440.8,0.058,0.024,0.0065,7561.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-16",24,24,849,,0.002,0.001,434,0.058,0.025,0.0068,7444.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-17",24,24,875,,0.002,0.001,443.2,0.058,0.026,0.0069,7603.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-18",24,24,880,,0.002,0.001,445.9,0.058,0.026,0.0067,7650,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-19",24,24,852,,0.002,0.001,433.7,0.058,0.027,0.0071,7442.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-20",24,24,884,,0.002,0.001,445.3,0.058,0.026,0.0069,7643,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-21",24,24,861,,0.002,0.001,437.7,0.058,0.026,0.007,7511,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-22",24,24,888,,0.002,0.001,443.9,0.058,0.027,0.0071,7618.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-23",24,24,880,,0.002,0.001,441.8,0.058,0.025,0.0067,7579.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-24",24,24,918,,0.002,0.001,456.5,0.058,0.026,0.0066,7833.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-25",24,24,878,,0.002,0.001,439.4,0.058,0.024,0.0065,7542.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-26",24,24,987,,0.002,0.001,483.5,0.058,0.027,0.0066,8294.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-27",24,24,940,,0.002,0.001,471.6,0.058,0.028,0.0068,8092.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-28",24,24,895,,0.002,0.001,453.6,0.058,0.026,0.0068,7783.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-29",24,24,951,,0.002,0.001,479.3,0.058,0.028,0.0069,8219.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-30",24,24,934,,0.002,0.001,473.9,0.058,0.028,0.0069,8126.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-07-31",1,0.08,0,,0,0.001,0.4,0.058,0,0.009,6.864,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-01",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-02",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-03",17,16.57,578.56,,0.002,0.001,302.602,0.058,0.019,0.0103,5191.275,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-04",24,24,855,,0.002,0.001,431.1,0.058,0.024,0.0066,7396.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-05",24,24,857,,0.002,0.001,426.8,0.058,0.024,0.0065,7329.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-06",24,24,840,,0.002,0.001,429.3,0.058,0.025,0.0068,7367.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-07",24,24,848,,0.002,0.001,431.4,0.058,0.025,0.0067,7402.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-08",24,24,813,,0.002,0.001,421.9,0.058,0.025,0.007,7239.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-09",24,24,866,,0.002,0.001,443.7,0.058,0.025,0.0067,7613.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-10",24,24,816,,0.002,0.001,413.2,0.058,0.024,0.0069,7090.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-11",24,24,789,,0.002,0.001,402.2,0.058,0.024,0.007,6900.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-12",24,24,916,,0.002,0.001,443.5,0.058,0.024,0.0064,7609.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-13",24,24,1037,,0.003,0.001,511.7,0.058,0.03,0.0068,8782.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-14",24,24,1026,,0.003,0.001,524.1,0.058,0.03,0.0065,8996.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-15",24,24,1099,,0.003,0.001,578.3,0.058,0.033,0.0065,9920.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-16",24,24,1080,,0.003,0.001,562.5,0.058,0.032,0.0066,9650.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-17",24,24,1120,,0.003,0.001,584.6,0.058,0.035,0.007,10031.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-18",24,24,1083,,0.003,0.001,542.6,0.058,0.032,0.0068,9309.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-19",24,24,969,,0.003,0.001,487.6,0.058,0.027,0.0063,8367.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-20",24,24,789,,0.002,0.001,411.3,0.058,0.024,0.0069,7058,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-21",24,24,850,,0.002,0.001,436.5,0.058,0.022,0.006,7486.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-22",24,24,984,,0.003,0.001,489,0.058,0.028,0.0066,8390,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-23",24,24,1187,,0.003,0.001,580.9,0.058,0.034,0.0067,9966.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-24",24,24,1007,,0.003,0.001,492.6,0.058,0.025,0.0058,8447.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-25",24,24,827,,0.002,0.001,427.6,0.058,0.025,0.0068,7334.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-26",24,24,778,,0.002,0.001,405.7,0.058,0.024,0.0069,6963.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-27",24,24,796,,0.002,0.001,412.7,0.058,0.024,0.0069,7083.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-28",10,9.15,289.35,,0.001,0.001,152.43,0.058,0.009,0.008,2613.445,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-29",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-30",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-08-31",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-01",12,11.48,347.28,,0.001,0.001,187.648,0.058,0.013,0.0111,3220.444,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-02",24,24,772,,0.002,0.001,405.5,0.058,0.023,0.0067,6955.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-03",24,24,861,,0.002,0.001,439.3,0.058,0.023,0.0062,7536.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-04",24,24,960,,0.002,0.001,479.6,0.058,0.027,0.0065,8228.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-05",24,24,893,,0.002,0.001,459.3,0.058,0.027,0.0068,7878.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-06",24,24,966,,0.003,0.001,492.1,0.058,0.029,0.0069,8439.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-07",24,24,1026,,0.003,0.001,502.6,0.058,0.029,0.0068,8627.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-08",24,24,894,,0.002,0.001,451.1,0.058,0.025,0.0066,7742.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-09",24,24,787,,0.002,0.001,409.9,0.058,0.024,0.0069,7031.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-10",24,24,872,,0.002,0.001,443.9,0.058,0.025,0.0065,7613.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-11",17,16.08,590,,0.002,0.001,299.228,0.058,0.017,0.0072,5128.324,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-12",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-13",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-14",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-15",18,17.52,592.68,,0.002,0.001,309.632,0.058,0.021,0.0123,5310.864,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-16",24,24,835,,0.002,0.001,428.8,0.058,0.023,0.0062,7361.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-17",24,24,943,,0.002,0.001,475.8,0.058,0.027,0.0066,8164.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-18",1,0.12,0.24,,0,0.001,0.624,0.058,0,0.007,10.704,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-19",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-20",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-21",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-22",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-23",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-24",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-25",14,13.65,416.85,,0.001,0.001,226.185,0.058,0.016,0.0113,3883.65,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-26",24,24,787,,0.002,0.001,411.5,0.058,0.023,0.0067,7061.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-27",24,24,784,,0.002,0.001,409.1,0.058,0.025,0.007,7021,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-28",24,24,925,,0.003,0.001,486.2,0.058,0.028,0.0068,8343.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-29",24,24,888,,0.002,0.001,459.4,0.058,0.026,0.0066,7881.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-09-30",24,24,933,,0.002,0.001,483.1,0.058,0.026,0.0062,8291.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-01",24,24,926,,0.002,0.001,473,0.058,0.026,0.0064,8115.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-02",24,24,905,,0.002,0.001,458.1,0.058,0.025,0.0065,7856.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-03",24,24,913,,0.002,0.001,461.3,0.058,0.026,0.0066,7912.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-04",24,24,921,,0.002,0.001,466.6,0.058,0.025,0.0063,8010.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-05",24,24,975,,0.003,0.001,492,0.058,0.029,0.0068,8435.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-06",24,24,1050,,0.003,0.001,510.8,0.058,0.027,0.0061,8761.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-07",24,24,934,,0.002,0.001,466,0.058,0.022,0.0056,7993.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-08",24,24,821,,0.002,0.001,422.7,0.058,0.022,0.0061,7248.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-09",10,9.07,299,,0.001,0.001,155.143,0.058,0.009,0.0071,2661.073,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-10",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-11",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-12",17,16.93,534.09,,0.001,0.001,285.144,0.058,0.019,0.0086,4889.464,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-13",24,24,836,,0.002,0.001,430.6,0.058,0.025,0.0067,7387.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-14",24,24,923,,0.002,0.001,463.6,0.058,0.026,0.0067,7953.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-15",24,24,964,,0.002,0.001,480,0.058,0.027,0.0065,8232.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-16",24,24,870,,0.002,0.001,444,0.058,0.025,0.0065,7620.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-17",24,24,816,,0.002,0.001,421.2,0.058,0.025,0.0069,7224.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-18",24,24,946,,0.002,0.001,473.8,0.058,0.023,0.0055,8123.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-19",24,24,998,,0.003,0.001,499.7,0.058,0.026,0.0061,8571.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-20",24,24,832,,0.002,0.001,428.6,0.058,0.023,0.0062,7350,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-21",24,24,909,,0.002,0.001,456.5,0.058,0.025,0.0065,7835,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-22",24,24,860,,0.002,0.001,438.4,0.058,0.026,0.007,7523.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-23",24,24,837,,0.002,0.001,429.7,0.058,0.022,0.006,7373.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-24",24,24,869,,0.002,0.001,441.3,0.058,0.022,0.0058,7574.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-25",24,24,961,,0.002,0.001,477.2,0.058,0.026,0.0063,8186.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-26",24,24,903,,0.002,0.001,460.1,0.058,0.025,0.0062,7900.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-27",24,24,1004,,0.003,0.001,499.3,0.058,0.028,0.0064,8563.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-28",24,24,860,,0.002,0.001,439.6,0.058,0.023,0.0061,7543.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-29",24,24,834,,0.002,0.001,429.8,0.058,0.023,0.0063,7370.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-30",24,24,834,,0.002,0.001,430,0.058,0.024,0.0066,7374.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-10-31",6,4.96,124.68,,0,0.001,71.58,0.058,0.008,0.0235,1227.302,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-01",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-02",14,13.08,484,,0.001,0.001,248.276,0.0581,0.016,0.0122,4260.216,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-03",24,24,932,,0.002,0.001,467.7,0.058,0.025,0.0062,8026.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-04",24,24,1000,,0.003,0.001,494.7,0.058,0.028,0.0066,8488.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-05",24,24,1014,,0.003,0.001,504,0.058,0.025,0.0055,8648.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-06",11,10.07,332,,0.001,0.001,173.743,0.058,0.009,0.0066,2981.28,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-07",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-08",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-09",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-10",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-11",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-12",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-13",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-14",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-15",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-16",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-17",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-18",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-19",14,13.08,418.08,,0.001,0.001,226.692,0.0581,0.015,0.0139,3890.596,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-20",24,24,917,,0.002,0.001,457.3,0.058,0.024,0.0062,7846.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-21",24,24,958,,0.002,0.001,473.1,0.058,0.024,0.0058,8119.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-22",24,24,956,,0.002,0.001,475.4,0.058,0.024,0.0059,8158.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-23",24,24,843,,0.002,0.001,434,0.058,0.022,0.0059,7445.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-24",24,24,874,,0.002,0.001,445.7,0.058,0.025,0.0065,7644.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-25",24,24,888,,0.002,0.001,449.4,0.058,0.024,0.0061,7711.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-26",24,24,922,,0.002,0.001,463.3,0.058,0.025,0.0062,7949.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-27",24,24,848,,0.002,0.001,433.7,0.058,0.024,0.0063,7445,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-28",24,24,915,,0.002,0.001,461.3,0.058,0.027,0.0069,7918.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-29",24,24,989,,0.003,0.001,496.3,0.058,0.028,0.0064,8514.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-11-30",24,24,966,,0.002,0.001,482.3,0.058,0.027,0.0066,8280.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-01",24,24,1063,,0.003,0.001,523.9,0.058,0.029,0.0063,8991.3,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-02",24,24,1039,,0.003,0.001,513.6,0.058,0.026,0.0058,8816.7,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-03",24,24,1058,,0.003,0.001,521.8,0.058,0.029,0.0064,8950.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-04",24,24,1108,,0.003,0.001,547.7,0.058,0.033,0.007,9400.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-05",12,10.88,475.48,,0.001,0.001,235.416,0.058,0.017,0.0178,4038.334,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-06",24,24,943,,0.002,0.001,473.7,0.058,0.024,0.0058,8123.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-07",24,24,972,,0.002,0.001,482.9,0.058,0.028,0.0069,8282.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-08",24,24,958,,0.002,0.001,484,0.058,0.027,0.0066,8304.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-09",24,24,939,,0.002,0.001,474.2,0.058,0.027,0.0065,8140.1,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-10",24,24,1023,,0.003,0.001,511.5,0.058,0.03,0.0069,8777.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-11",15,14.07,545,,0.001,0.001,275.787,0.058,0.015,0.0067,4730.835,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-12",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-13",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-14",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-15",16,15.08,604,,0.002,0.001,309.844,0.058,0.02,0.0113,5315.088,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-16",24,24,1103,,0.003,0.001,541.7,0.058,0.033,0.007,9293,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-17",24,24,867,,0.002,0.001,445.7,0.058,0.025,0.0065,7651.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-18",14,13.12,486.36,,0.001,0.001,246.92,0.058,0.015,0.0069,4234.784,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-19",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-20",0,0,,,,,,,,,,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-21",9,8.23,269.38,,0.001,0.001,143.748,0.058,0.011,0.0193,2466.969,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-22",24,24,907,,0.002,0.001,458.8,0.058,0.026,0.0066,7874.8,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-23",24,24,963,,0.002,0.001,483.8,0.058,0.028,0.0067,8302.2,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-24",24,24,992,,0.003,0.001,494,0.058,0.029,0.0068,8473.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-25",24,24,864,,0.002,0.001,442,0.058,0.023,0.0062,7581.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-26",24,24,807,,0.002,0.001,420.4,0.058,0.024,0.0067,7212.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-27",24,24,983,,0.003,0.001,493.8,0.058,0.029,0.0068,8473.9,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-28",24,24,1036,,0.003,0.001,511.4,0.058,0.03,0.0068,8774.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-29",24,24,1035,,0.003,0.001,506.1,0.058,0.029,0.0066,8681.6,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-30",24,24,824,,0.002,0.001,431.3,0.058,0.024,0.0066,7399.5,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"1",,"2020-12-31",24,24,917,,0.003,0.001,500.2,0.0604,0.026,0.0064,8200.4,"Natural Gas","Other Gas","Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-05",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-09",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-19",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-30",2,0.83,11.88,,0,0.001,9.642,0.059,0.002,0.043,162.872,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-01-31",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-05",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-09",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-19",18,17.23,532.3,,0.002,0.001,334.354,0.0592,0.04,0.0154,5626.966,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-20",1,0.03,0,,0,0.001,0.153,0.06,0,0.037,2.55,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-24",8,6.25,138.24,,0,0.001,94.826,0.0593,0.012,0.0311,1595.619,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-02-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-05",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-09",4,2.6,65.2,,0,0.001,43,0.0595,0.006,0.0265,722.68,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-16",16,14.24,426.6,,0.001,0.001,267.116,0.0592,0.037,0.0222,4496.056,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-19",6,4.3,114.42,,0,0.001,74.972,0.0595,0.008,0.0205,1260.14,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-30",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-03-31",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-05",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-09",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-19",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-21",2,1.22,40.86,,0,0.001,24.942,0.059,0.004,0.033,419.64,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-22",2,1.93,43.74,,0,0.001,29.669,0.0595,0.004,0.0165,498.62,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-04-30",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-05",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-09",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-19",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-26",6,5.38,128.98,,0,0.001,85.634,0.059,0.013,0.0188,1441.78,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-27",9,8.1,196.92,,0.001,0.001,130.836,0.0594,0.019,0.019,2199.886,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-30",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-05-31",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-05",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-09",4,2.55,52.68,,0,0.001,37.15,0.0595,0.005,0.0288,625.667,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-18",5,4.33,85.62,,0,0.001,60.961,0.0592,0.008,0.0174,1026.211,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-19",3,1.3,7.92,,0,0.001,9.869,0.06,0.004,0.0563,165.415,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-20",2,0.89,8.06,,0,0.001,8.208,0.0595,0.003,0.044,137.946,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-26",5,3.67,129.78,,0,0.001,78.801,0.0594,0.011,0.0204,1325.369,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-06-30",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-05",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-09",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-11",5,4.25,140.05,,0,0.001,85.889,0.0592,0.013,0.0196,1444.542,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-12",4,3.03,107.44,,0,0.001,65.017,0.0598,0.012,0.029,1092.881,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-19",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-27",6,5.27,133.76,,0,0.001,87.994,0.0593,0.012,0.0172,1480.214,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-29",3,2.48,77.84,,0,0.001,48.358,0.0597,0.008,0.02,813.232,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-30",4,3.38,121.48,,0,0.001,73.219,0.059,0.012,0.0205,1232.488,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-07-31",2,0.92,14.88,,0,0.001,11.1,0.0595,0.004,0.0365,186.656,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-05",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-09",6,4.33,107.2,,0,0.001,70.257,0.0595,0.009,0.0277,1181.866,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-13",8,6.53,243,,0.001,0.001,145.047,0.0593,0.02,0.0225,2440.869,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-14",11,10.36,378.74,,0.001,0.001,227.081,0.0591,0.031,0.017,3822.573,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-15",12,11.32,431.48,,0.001,0.001,257.284,0.059,0.034,0.0183,4332.848,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-16",11,9.08,334.11,,0.001,0.001,200.869,0.0594,0.028,0.0205,3378.538,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-17",12,10.64,386.44,,0.001,0.001,233.712,0.0593,0.031,0.0184,3930.744,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-18",13,12.46,459.56,,0.001,0.001,275.81,0.0592,0.036,0.0158,4641.264,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-19",7,6.05,221.51,,0.001,0.001,133.154,0.0593,0.019,0.0187,2238.744,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-30",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-08-31",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-05",6,5.73,206.46,,0.001,0.001,124.553,0.0592,0.018,0.0177,2096.449,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-06",8,7.21,195.72,,0.001,0.001,126.7,0.0591,0.018,0.0184,2132.028,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-09",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-17",15,13.25,281.35,,0.001,0.001,194.415,0.0595,0.026,0.0233,3269.49,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-19",3,1.67,47.18,,0,0.001,30.405,0.059,0.005,0.0323,511.419,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-28",5,4.33,154.07,,0,0.001,93.031,0.059,0.015,0.0214,1564.679,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-29",4,2.36,83.26,,0,0.001,50.65,0.0593,0.009,0.0188,851.556,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-09-30",6,5.19,195.75,,0.001,0.001,117.273,0.059,0.017,0.0178,1975.185,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-02",4,2.51,87.02,,0,0.001,53.143,0.0593,0.012,0.0433,894.623,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-04",3,2.07,66.43,,0,0.001,41.069,0.059,0.007,0.0257,690.963,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-05",6,3.59,93.23,,0,0.001,60.511,0.0592,0.011,0.0475,1018.821,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-07",2,0.95,14.55,,0,0.001,11.21,0.0595,0.003,0.085,188.155,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-09",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-19",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-30",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-10-31",2,0.92,15.56,,0,0.001,11.56,0.0595,0.002,0.0275,194.161,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-04",2,1.55,26.35,,0,0.001,19.576,0.059,0.004,0.023,329.939,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-05",4,2.99,54.48,,0,0.001,40.133,0.0595,0.003,0.0148,675.329,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-09",3,2.72,74.56,,0,0.001,48.14,0.059,0.009,0.0217,811.208,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-19",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-11-30",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-05",4,2.57,23.6,,0,0.001,24.45,0.06,0.01,0.0525,410.125,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-07",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-08",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-09",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-14",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-17",5,3.99,78.27,,0,0.001,56.136,0.059,0.011,0.0468,945.128,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-19",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-30",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Power Plant",7527,"2",,"2020-12-31",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-01",24,24,914,,0.002,0.001,449.8,0.0592,0.03,0.0078,7569,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-02",24,24,950,,0.002,0.001,465.2,0.0591,0.032,0.008,7831.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-03",24,24,916,,0.002,0.001,448.6,0.0593,0.03,0.008,7550.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-04",24,24,911,,0.002,0.001,447.3,0.0593,0.029,0.0076,7524.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-05",24,24,1159,,0.003,0.001,545.5,0.0592,0.038,0.0083,9178.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-06",24,24,926,,0.002,0.001,454.9,0.0592,0.03,0.0077,7653.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-07",24,24,1027,,0.002,0.001,492.7,0.0592,0.033,0.0079,8292.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-08",24,24,1044,,0.003,0.001,495.8,0.0591,0.034,0.0081,8349,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-09",2,1.08,44.16,,0,0.001,21.56,0.0595,0.001,0.0075,363.008,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-17",6,5.25,228.25,,0.001,0.001,109.725,0.0593,0.011,0.0478,1845.925,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-18",24,24,934,,0.002,0.001,463.1,0.0592,0.027,0.007,7795.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-19",24,24,1188,,0.003,0.001,567.6,0.0592,0.038,0.008,9549.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-20",24,24,1181,,0.003,0.001,565.7,0.0592,0.038,0.008,9518.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-21",24,24,1144,,0.003,0.001,549,0.0592,0.038,0.0082,9242.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-22",24,24,1117,,0.003,0.001,545,0.0593,0.037,0.008,9171.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-23",24,24,1152,,0.003,0.001,558.5,0.0592,0.039,0.0082,9400.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-24",24,24,1167,,0.003,0.001,560.8,0.0593,0.04,0.0084,9432.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-25",24,24,1169,,0.003,0.001,565.2,0.0593,0.04,0.0085,9508.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-26",24,24,1165,,0.003,0.001,561.2,0.0592,0.04,0.0085,9444.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-27",24,24,1161,,0.003,0.001,563.1,0.0595,0.04,0.0085,9468.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-28",24,24,1117,,0.003,0.001,540.1,0.0593,0.037,0.0081,9091.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-29",24,24,1024,,0.003,0.001,497.8,0.0591,0.034,0.0081,8376.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-30",24,24,1075,,0.003,0.001,517,0.0593,0.035,0.008,8699.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-01-31",24,24,1111,,0.003,0.001,532.1,0.0592,0.036,0.008,8952.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-01",13,12.33,550.61,,0.001,0.001,263.296,0.0593,0.018,0.0082,4429.941,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-03",17,16.72,773.96,,0.002,0.001,373.48,0.0592,0.03,0.0122,6288.808,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-04",24,24,1016,,0.002,0.001,493.9,0.059,0.032,0.0078,8315.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-05",24,24,1047,,0.003,0.001,501.3,0.0593,0.034,0.0081,8431,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-06",24,24,1080,,0.003,0.001,506.5,0.0594,0.035,0.0082,8522.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-07",24,24,977,,0.002,0.001,467.4,0.0593,0.03,0.0075,7861.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-08",24,24,958,,0.002,0.001,459.3,0.0593,0.03,0.0079,7729.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-09",24,24,951,,0.002,0.001,461.4,0.0594,0.031,0.0081,7761.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-10",24,24,1152,,0.003,0.001,559.9,0.0593,0.037,0.008,9421.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-11",24,24,1003,,0.002,0.001,477.7,0.0592,0.032,0.0079,8039.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-12",24,24,972,,0.002,0.001,471.3,0.0594,0.031,0.0078,7925.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-13",16,15.07,631.15,,0.002,0.001,303.656,0.0593,0.024,0.0098,5109.01,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-14",24,24,1010,,0.003,0.001,508.9,0.0592,0.034,0.008,8564.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-15",24,24,953,,0.002,0.001,463.8,0.0593,0.031,0.008,7803.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-16",24,24,1129,,0.003,0.001,559.7,0.0592,0.038,0.0081,9418.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-17",24,24,1090,,0.003,0.001,529.6,0.0593,0.036,0.0082,8910.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-18",24,24,1030,,0.003,0.001,499.3,0.0592,0.034,0.008,8404.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-19",24,24,1076,,0.003,0.001,515.7,0.0592,0.036,0.0083,8681.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-20",3,2.1,75.01,,0,0.001,38.448,0.059,0.005,0.0267,646.923,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-21",24,24,1072,,0.003,0.001,516.8,0.0592,0.034,0.0079,8697.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-22",24,24,1052,,0.003,0.001,514,0.0593,0.035,0.0081,8650.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-23",24,24,990,,0.002,0.001,481,0.0593,0.033,0.0081,8090.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-24",24,24,1050,,0.003,0.001,502.4,0.0593,0.034,0.008,8454.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-25",24,24,1142,,0.003,0.001,540.6,0.0592,0.036,0.008,9099,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-26",24,24,1263,,0.003,0.001,597.4,0.0593,0.04,0.008,10050.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-27",24,24,1182,,0.003,0.001,576.7,0.0592,0.04,0.0083,9704.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-28",24,24,974,,0.002,0.001,475.9,0.0593,0.032,0.0079,8008.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-02-29",24,24,1107,,0.003,0.001,547.1,0.059,0.038,0.0083,9210.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-01",24,24,1116,,0.003,0.001,553.9,0.0591,0.039,0.0083,9323.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-02",24,24,1123,,0.003,0.001,556.8,0.0593,0.038,0.0081,9370.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-03",24,24,1325,,0.003,0.001,656.3,0.0591,0.046,0.0083,11045.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-04",24,24,957,,0.002,0.001,477.9,0.0593,0.028,0.007,8042.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-05",24,24,1166,,0.003,0.001,575,0.0592,0.034,0.007,9676.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-06",24,24,968,,0.002,0.001,476.8,0.0592,0.028,0.007,8022.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-07",24,24,1144,,0.003,0.001,564.3,0.0593,0.034,0.0072,9494.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-08",24,24,1156,,0.003,0.001,549.9,0.0593,0.035,0.0075,9253,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-09",24,24,1132,,0.003,0.001,545.4,0.0593,0.031,0.0068,9179.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-10",24,24,1173,,0.003,0.001,553,0.0592,0.033,0.0072,9307.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-11",24,24,1111,,0.003,0.001,533,0.0592,0.032,0.007,8972.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-12",24,24,1079,,0.003,0.001,525.6,0.0592,0.031,0.007,8844.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-13",24,24,1063,,0.003,0.001,522.8,0.0592,0.031,0.007,8799.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-14",24,24,1186,,0.003,0.001,563.6,0.0592,0.034,0.0073,9483.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-15",24,24,1164,,0.003,0.001,553.4,0.0591,0.033,0.007,9312.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-16",24,24,1134,,0.003,0.001,538,0.0592,0.032,0.0072,9055.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-17",24,24,1069,,0.003,0.001,506.9,0.0593,0.031,0.0074,8528.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-18",24,24,1159,,0.003,0.001,540.6,0.0593,0.032,0.007,9098.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-19",24,24,1061,,0.003,0.001,506.2,0.0592,0.03,0.007,8521.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-20",16,15.6,567.6,,0.001,0.001,283.14,0.0594,0.016,0.0066,4764.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-21",1,0.55,5.5,,0,0.001,4.565,0.059,0.004,0.114,76.945,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-22",24,24,1056,,0.003,0.001,519.3,0.0592,0.033,0.0075,8738.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-23",24,24,947,,0.002,0.001,465.2,0.0594,0.026,0.0067,7825.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-24",24,24,1050,,0.003,0.001,502.6,0.0594,0.029,0.007,8454.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-25",24,24,927,,0.002,0.001,458.7,0.0595,0.028,0.0072,7712.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-26",24,24,966,,0.002,0.001,478.1,0.0592,0.027,0.0067,8049,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-27",24,24,1005,,0.002,0.001,489.9,0.0593,0.029,0.0069,8243.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-28",24,24,1036,,0.003,0.001,499.9,0.0593,0.028,0.0067,8408.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-29",24,24,960,,0.002,0.001,472.6,0.0593,0.027,0.0067,7952.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-30",24,24,984,,0.002,0.001,478.6,0.0594,0.027,0.0068,8046.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-03-31",24,24,897,,0.002,0.001,447.8,0.0594,0.026,0.0069,7531.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-01",24,24,983,,0.002,0.001,479.2,0.0592,0.027,0.0068,8063.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-02",24,24,1086,,0.003,0.001,518,0.0592,0.031,0.0072,8718.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-03",24,24,993,,0.002,0.001,480.8,0.0594,0.029,0.0072,8087.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-04",24,24,1033,,0.002,0.001,493.6,0.0593,0.028,0.0068,8304.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-05",24,24,1041,,0.002,0.001,494.6,0.0593,0.028,0.0068,8321.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-06",24,23.98,1018.22,,0.002,0.001,487.314,0.0593,0.027,0.0067,8200.614,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-07",24,24,939,,0.002,0.001,463.1,0.0592,0.026,0.0068,7794,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-08",24,24,1096,,0.003,0.001,523.4,0.0593,0.03,0.0069,8805.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-09",24,24,1125,,0.003,0.001,535.9,0.0594,0.032,0.0071,9014.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-10",24,24,1015,,0.002,0.001,491.7,0.0592,0.029,0.0071,8275.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-11",24,24,906,,0.002,0.001,452.6,0.0593,0.026,0.0069,7612.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-12",24,24,1075,,0.003,0.001,515.7,0.0591,0.03,0.0069,8681.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-13",24,24,911,,0.002,0.001,451.5,0.0592,0.026,0.0069,7603.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-14",24,24,864,,0.002,0.001,430.6,0.0592,0.026,0.0071,7246.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-15",24,24,928,,0.002,0.001,459.6,0.0593,0.027,0.0071,7733.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-16",1,0.08,0.08,,0,0.001,0.328,0.059,0,0.008,5.536,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-24",11,10.97,427.49,,0.001,0.001,223.852,0.0594,0.02,0.0134,3763.968,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-25",24,24,1136,,0.003,0.001,561,0.0592,0.033,0.007,9440.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-26",24,24,1127,,0.003,0.001,567,0.0591,0.034,0.0072,9542.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-27",24,24,1130,,0.003,0.001,568.6,0.0592,0.034,0.0072,9565.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-28",24,24,1103,,0.003,0.001,559.2,0.0593,0.033,0.0071,9410.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-29",24,24,1161,,0.003,0.001,586.6,0.0593,0.036,0.0073,9871.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-04-30",24,24,1197,,0.003,0.001,601.9,0.0593,0.037,0.0073,10125.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-01",24,24,1190,,0.003,0.001,598.6,0.0593,0.038,0.0075,10069.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-02",24,24,1212,,0.003,0.001,607.8,0.0593,0.038,0.0074,10228.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-03",24,24,1190,,0.003,0.001,599.4,0.0593,0.037,0.0074,10083.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-04",24,24,1153,,0.003,0.001,583.7,0.0593,0.036,0.0073,9821.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-05",24,24,1138,,0.003,0.001,578,0.0592,0.036,0.0073,9725.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-06",24,24,1166,,0.003,0.001,590.3,0.0591,0.036,0.0072,9936.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-07",24,24,1125,,0.003,0.001,570.4,0.0593,0.035,0.0072,9595.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-08",24,24,1019,,0.003,0.001,512,0.0593,0.031,0.0071,8613.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-09",24,24,902,,0.002,0.001,462.4,0.0592,0.028,0.0072,7782.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-10",24,24,830,,0.002,0.001,429.1,0.0591,0.026,0.0073,7225.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-11",24,24,961,,0.002,0.001,487.4,0.0594,0.029,0.0071,8201.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-12",24,24,1124,,0.003,0.001,558.9,0.0592,0.035,0.0074,9405.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-13",24,24,1105,,0.003,0.001,556.5,0.0593,0.034,0.0072,9362,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-14",24,24,1118,,0.003,0.001,562,0.0592,0.034,0.0072,9456.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-15",24,24,1082,,0.003,0.001,545.5,0.0592,0.034,0.0074,9178.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-16",24,24,1073,,0.003,0.001,540.3,0.0593,0.033,0.0073,9092.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-17",24,24,1117,,0.003,0.001,561.3,0.0592,0.034,0.0073,9448.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-18",24,24,1112,,0.003,0.001,562.1,0.0591,0.035,0.0075,9460.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-19",24,24,1065,,0.003,0.001,536.6,0.0592,0.032,0.0072,9030.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-20",24,24,1026,,0.003,0.001,526.3,0.0592,0.031,0.0071,8857.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-21",24,24,1035,,0.003,0.001,530.6,0.0593,0.031,0.0069,8925.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-22",24,24,1098,,0.003,0.001,554,0.0593,0.034,0.0073,9323.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-23",24,24,1087,,0.003,0.001,547.8,0.0592,0.034,0.0073,9219.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-24",24,24,1112,,0.003,0.001,558.1,0.0593,0.034,0.0073,9385.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-25",24,24,1083,,0.003,0.001,542.2,0.0592,0.033,0.0072,9125.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-26",24,24,917,,0.002,0.001,459.9,0.0593,0.028,0.0071,7736.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-27",24,24,911,,0.002,0.001,458.3,0.0592,0.028,0.0072,7713.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-28",24,24,886,,0.002,0.001,449,0.0593,0.027,0.0071,7559.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-29",24,24,925,,0.002,0.001,470,0.0593,0.028,0.0071,7907.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-30",24,24,873,,0.002,0.001,450,0.0592,0.026,0.007,7572.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-05-31",24,24,823,,0.002,0.001,430.3,0.0593,0.025,0.007,7240.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-01",24,24,888,,0.002,0.001,455,0.0593,0.026,0.0069,7654.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-02",24,24,945,,0.002,0.001,480,0.0593,0.027,0.0068,8078.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-03",24,24,1067,,0.003,0.001,540.4,0.0593,0.032,0.007,9095.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-04",24,24,1130,,0.003,0.001,566.2,0.0593,0.034,0.007,9525.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-05",21,20.13,726.52,,0.002,0.001,372.654,0.0592,0.022,0.007,6273.162,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-06",5,4.73,187.68,,0,0.001,97.53,0.059,0.011,0.0224,1642.388,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-07",24,24,1095,,0.003,0.001,566.8,0.0594,0.034,0.0071,9532.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-08",24,24,1031,,0.003,0.001,521.2,0.0591,0.032,0.0072,8771.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-09",24,24,948,,0.003,0.001,496.1,0.0594,0.03,0.0073,8344.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-10",24,24,997,,0.003,0.001,525.6,0.0591,0.032,0.0073,8848.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-11",24,24,908,,0.002,0.001,459.5,0.0593,0.027,0.007,7730.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-12",24,24,914,,0.002,0.001,461.4,0.0593,0.027,0.0069,7765,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-13",24,24,912,,0.002,0.001,462.3,0.0593,0.028,0.0071,7778.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-14",24,24,876,,0.002,0.001,448.7,0.0593,0.027,0.0072,7548.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-15",24,24,964,,0.002,0.001,487.8,0.0592,0.029,0.0072,8205.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-16",24,24,1115,,0.003,0.001,568.8,0.0592,0.034,0.0072,9573.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-17",24,24,1046,,0.003,0.001,536.1,0.0593,0.032,0.0071,9019.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-18",24,24,1064,,0.003,0.001,532.5,0.0592,0.031,0.0069,8962.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-19",24,24,1132,,0.003,0.001,572.7,0.0593,0.034,0.0071,9634.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-20",24,24,1026,,0.003,0.001,519.3,0.0592,0.032,0.0074,8741.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-21",24,24,919,,0.002,0.001,469.1,0.0593,0.029,0.0073,7894.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-22",24,24,911,,0.002,0.001,468.1,0.0591,0.028,0.0072,7878.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-23",24,24,972,,0.002,0.001,493.3,0.0593,0.029,0.0069,8300.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-24",24,24,966,,0.002,0.001,487.1,0.0593,0.028,0.0068,8200.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-25",24,24,950,,0.002,0.001,487.5,0.0592,0.029,0.0071,8204.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-26",24,24,1040,,0.003,0.001,524.5,0.0593,0.031,0.0069,8826.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-27",24,24,986,,0.003,0.001,501.7,0.0593,0.03,0.007,8441.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-28",24,24,936,,0.002,0.001,477.3,0.0592,0.027,0.0068,8032.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-29",24,24,1153,,0.003,0.001,575.3,0.0592,0.036,0.0073,9682,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-06-30",24,24,898,,0.002,0.001,460,0.0593,0.027,0.0071,7741.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-01",24,24,939,,0.002,0.001,482.3,0.0593,0.028,0.0068,8112.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-02",24,24,928,,0.002,0.001,479.4,0.0593,0.03,0.0074,8064.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-03",24,24,964,,0.002,0.001,491.9,0.0592,0.03,0.0072,8277,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-04",24,24,936,,0.002,0.001,483.9,0.0593,0.028,0.0069,8138.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-05",24,24,974,,0.003,0.001,498.6,0.0593,0.03,0.007,8387.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-06",24,24,948,,0.002,0.001,481.7,0.0592,0.028,0.007,8106.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-07",24,24,1044,,0.003,0.001,528.3,0.0592,0.032,0.0071,8890.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-08",24,24,957,,0.002,0.001,481.8,0.0593,0.029,0.0071,8109.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-09",24,24,946,,0.002,0.001,482.3,0.0593,0.028,0.007,8115.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-10",24,24,951,,0.002,0.001,488.3,0.0595,0.029,0.0069,8212.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-11",24,24,1080,,0.003,0.001,542.9,0.0593,0.033,0.0072,9137.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-12",24,24,1004,,0.003,0.001,511.5,0.0594,0.031,0.0071,8606.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-13",24,24,916,,0.002,0.001,469,0.0591,0.027,0.0069,7891.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-14",24,24,912,,0.002,0.001,470.5,0.0593,0.028,0.007,7913.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-15",24,24,893,,0.002,0.001,463.3,0.0593,0.027,0.0069,7795,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-16",24,24,885,,0.002,0.001,459.6,0.0592,0.027,0.007,7734.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-17",24,24,913,,0.002,0.001,468.6,0.0592,0.027,0.007,7885.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-18",13,11.81,465.36,,0.001,0.001,235.175,0.0592,0.017,0.0125,3957.471,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-19",24,24,1130,,0.003,0.001,569.4,0.0593,0.036,0.0074,9579.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-20",24,24,1128,,0.003,0.001,570.1,0.0593,0.035,0.0073,9589.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-21",24,24,1126,,0.003,0.001,569.7,0.0592,0.036,0.0075,9583.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-22",24,24,1110,,0.003,0.001,562.9,0.0591,0.035,0.0073,9475.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-23",24,24,951,,0.002,0.001,480.8,0.0592,0.029,0.0072,8091,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-24",24,24,944,,0.002,0.001,477.8,0.0592,0.029,0.0071,8040.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-25",24,24,932,,0.002,0.001,473.8,0.0593,0.028,0.007,7969.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-26",24,24,1054,,0.003,0.001,532.1,0.0592,0.031,0.0069,8953.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-27",24,24,1137,,0.003,0.001,568.8,0.0593,0.034,0.0071,9568.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-28",24,24,965,,0.002,0.001,492.4,0.0593,0.029,0.007,8282.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-29",24,24,995,,0.003,0.001,504.1,0.0592,0.03,0.0071,8481.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-30",24,24,1033,,0.003,0.001,524.8,0.0591,0.032,0.0073,8832.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-07-31",24,24,908,,0.002,0.001,465.1,0.0595,0.027,0.0069,7823.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-01",24,24,876,,0.002,0.001,442.5,0.0593,0.026,0.007,7447,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-02",24,24,879,,0.002,0.001,450.5,0.0592,0.027,0.0071,7581.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-03",24,24,881,,0.002,0.001,452.2,0.0592,0.028,0.0073,7612.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-04",24,24,890,,0.002,0.001,455.2,0.0595,0.028,0.0073,7655.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-05",24,24,879,,0.002,0.001,448.5,0.0593,0.026,0.0069,7544.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-06",24,24,838,,0.002,0.001,429.5,0.0593,0.026,0.0071,7225.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-07",24,24,942,,0.002,0.001,474.7,0.0592,0.028,0.0069,7988.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-08",24,24,918,,0.002,0.001,464.3,0.0592,0.027,0.0069,7814.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-09",24,24,985,,0.003,0.001,499.6,0.0592,0.029,0.0069,8408.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-10",24,24,914,,0.002,0.001,464.1,0.0591,0.027,0.007,7815.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-11",24,24,904,,0.002,0.001,460.3,0.0592,0.028,0.0073,7748.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-12",24,24,951,,0.002,0.001,477.6,0.0591,0.028,0.007,8038.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-13",24,24,1105,,0.003,0.001,550.5,0.0592,0.033,0.0071,9260.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-14",24,24,1143,,0.003,0.001,568.1,0.0593,0.033,0.0068,9558.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-15",24,24,1177,,0.003,0.001,587.4,0.0591,0.035,0.0071,9885.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-16",24,24,1154,,0.003,0.001,573.1,0.0593,0.035,0.0072,9644.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-17",24,24,1233,,0.003,0.001,612.4,0.059,0.039,0.0076,10302.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-18",24,24,1216,,0.003,0.001,602,0.0592,0.037,0.0073,10130.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-19",24,24,1052,,0.003,0.001,530.4,0.0592,0.031,0.0069,8925.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-20",24,24,870,,0.002,0.001,449,0.0594,0.026,0.007,7551.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-21",24,24,960,,0.002,0.001,479.9,0.0592,0.028,0.007,8075.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-22",24,24,1015,,0.003,0.001,504.4,0.0593,0.03,0.007,8484.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-23",24,24,990,,0.003,0.001,496.5,0.0592,0.029,0.007,8355,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-24",24,24,1085,,0.003,0.001,540.1,0.0593,0.032,0.007,9086,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-25",24,24,929,,0.002,0.001,473.9,0.0594,0.027,0.0069,7972,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-26",24,24,881,,0.002,0.001,452.9,0.0595,0.026,0.0069,7617,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-27",24,24,1073,,0.003,0.001,535,0.0593,0.032,0.0071,9001.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-28",24,24,956,,0.002,0.001,484.7,0.0592,0.028,0.007,8159.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-29",24,24,902,,0.002,0.001,459.5,0.0592,0.027,0.0069,7733.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-30",24,24,872,,0.002,0.001,447.9,0.0594,0.027,0.0072,7536.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-08-31",24,24,904,,0.002,0.001,459.6,0.0593,0.028,0.0073,7733.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-01",24,24,892,,0.002,0.001,458.2,0.0593,0.028,0.0072,7711,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-02",24,24,873,,0.002,0.001,453.4,0.0594,0.027,0.0071,7628.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-03",24,24,971,,0.002,0.001,489.5,0.0591,0.029,0.007,8236.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-04",24,24,1028,,0.003,0.001,516.9,0.0592,0.031,0.0072,8700.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-05",24,24,1019,,0.003,0.001,521.9,0.0593,0.031,0.0071,8780.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-06",24,24,1062,,0.003,0.001,537.9,0.0595,0.032,0.007,9046.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-07",24,24,1017,,0.003,0.001,515.6,0.0592,0.03,0.0069,8675.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-08",24,24,965,,0.002,0.001,490.7,0.0593,0.029,0.0071,8254,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-09",24,24,870,,0.002,0.001,451.2,0.0592,0.027,0.0071,7594.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-10",24,24,950,,0.002,0.001,483.1,0.0593,0.028,0.007,8127.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-11",24,24,1008,,0.003,0.001,508.2,0.0592,0.031,0.0071,8548.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-12",8,7.26,282.76,,0.001,0.001,144.718,0.0594,0.011,0.0105,2436.68,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-13",24,24,1092,,0.003,0.001,552.9,0.0592,0.033,0.0071,9305,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-14",24,24,955,,0.002,0.001,488.9,0.0593,0.029,0.0072,8224.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-15",24,24,986,,0.003,0.001,503.4,0.0592,0.031,0.0073,8472.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-16",24,24,930,,0.002,0.001,477.1,0.0594,0.028,0.007,8026.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-17",24,24,1033,,0.003,0.001,520.9,0.0592,0.03,0.0069,8766.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-18",24,24,978,,0.003,0.001,496.8,0.0591,0.028,0.0068,8365,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-19",24,24,947,,0.002,0.001,488,0.0592,0.029,0.0071,8210.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-20",24,24,963,,0.003,0.001,496.4,0.0593,0.03,0.0072,8351.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-21",24,24,943,,0.002,0.001,489.7,0.0593,0.029,0.0071,8240.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-22",24,24,1057,,0.003,0.001,538.6,0.0591,0.032,0.0072,9065.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-23",24,24,994,,0.003,0.001,506.6,0.0594,0.03,0.007,8521.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-24",24,24,882,,0.002,0.001,461.2,0.0593,0.028,0.0072,7758.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-25",24,24,879,,0.002,0.001,458.9,0.0592,0.027,0.007,7724.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-26",24,24,858,,0.002,0.001,449,0.0593,0.027,0.0071,7555.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-27",24,24,879,,0.002,0.001,461.5,0.0593,0.027,0.007,7764.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-28",24,24,960,,0.003,0.001,500.7,0.0592,0.03,0.0071,8423.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-29",24,24,977,,0.003,0.001,505.2,0.0593,0.03,0.0071,8502.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-09-30",24,24,1035,,0.003,0.001,530.2,0.0593,0.031,0.0069,8920.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-01",24,24,991,,0.003,0.001,513.5,0.0591,0.03,0.0069,8644.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-02",24,24,1029,,0.003,0.001,525.3,0.0591,0.031,0.007,8843.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-03",24,24,970,,0.002,0.001,493.9,0.0594,0.028,0.0068,8306.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-04",24,24,992,,0.003,0.001,502.8,0.0593,0.028,0.0067,8462.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-05",24,24,1031,,0.003,0.001,514.7,0.0593,0.03,0.007,8658.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-06",24,24,1085,,0.003,0.001,532.2,0.0592,0.032,0.0071,8955.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-07",24,24,1017,,0.003,0.001,500.4,0.0592,0.029,0.0068,8421.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-08",24,24,913,,0.002,0.001,456.9,0.0594,0.027,0.007,7682.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-09",24,24,891,,0.002,0.001,444,0.0593,0.025,0.0068,7472.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-10",24,24,946,,0.002,0.001,470.8,0.0593,0.027,0.0069,7920.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-11",1,0.07,0.07,,0,0.001,0.336,0.06,0,0.007,5.642,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-15",6,5.15,194,,0,0.001,98.155,0.0592,0.012,0.0373,1651.805,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-16",24,24,933,,0.002,0.001,457.8,0.0591,0.028,0.0073,7704.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-17",24,24,906,,0.002,0.001,441.9,0.0595,0.026,0.0071,7433.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-18",24,24,1290,,0.003,0.001,622.4,0.0592,0.038,0.0073,10471.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-19",24,24,1231,,0.003,0.001,615.4,0.0593,0.037,0.0071,10358,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-20",18,17.6,844.4,,0.002,0.001,416.36,0.0592,0.025,0.007,7004.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-21",15,14.13,542,,0.001,0.001,272.655,0.0593,0.018,0.0099,4588.831,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-22",24,24,967,,0.002,0.001,476.7,0.0593,0.028,0.007,8023,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-23",24,24,946,,0.002,0.001,472.7,0.0593,0.028,0.007,7957.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-24",24,24,942,,0.002,0.001,469.2,0.0592,0.027,0.0068,7895.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-25",24,24,1005,,0.003,0.001,499.3,0.0592,0.03,0.007,8401.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-26",24,24,1003,,0.003,0.001,498.2,0.0592,0.03,0.007,8385.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-27",24,24,1031,,0.003,0.001,506.7,0.0591,0.031,0.0073,8527.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-28",24,24,996,,0.002,0.001,495.2,0.0592,0.03,0.0072,8334.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-29",24,24,901,,0.002,0.001,455.3,0.0594,0.026,0.0069,7658.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-30",24,24,931,,0.002,0.001,469.1,0.0591,0.028,0.0071,7895,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-10-31",24,24,893,,0.002,0.001,451.9,0.0593,0.025,0.0066,7602.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-01",24,24,919,,0.002,0.001,456,0.0592,0.027,0.0069,7675.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-02",24,24,1109,,0.003,0.001,534.2,0.0591,0.033,0.0073,8988.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-03",24,24,1003,,0.002,0.001,492.6,0.0593,0.028,0.0067,8289.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-04",24,24,1021,,0.003,0.001,500,0.0594,0.029,0.0069,8414.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-05",24,24,1070,,0.003,0.001,514.9,0.0593,0.03,0.007,8662.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-06",24,24,921,,0.002,0.001,457.2,0.0592,0.026,0.0068,7691.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-07",24,24,873,,0.002,0.001,444.9,0.0593,0.026,0.007,7484.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-08",24,24,900,,0.002,0.001,439.5,0.0593,0.026,0.0071,7393.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-09",24,24,1004,,0.002,0.001,485.6,0.0593,0.029,0.0071,8172.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-10",24,24,983,,0.002,0.001,480,0.0595,0.028,0.0069,8074.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-11",24,24,907,,0.002,0.001,447.5,0.0595,0.025,0.0068,7525,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-12",24,24,976,,0.002,0.001,475.3,0.0593,0.029,0.0073,7994.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-13",24,24,907,,0.002,0.001,448.3,0.0594,0.026,0.0069,7543.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-14",24,24,862,,0.002,0.001,431.7,0.0594,0.025,0.0069,7260.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-15",24,24,1133,,0.003,0.001,555.5,0.0592,0.034,0.0073,9347.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-16",24,24,1135,,0.003,0.001,548.5,0.059,0.035,0.0075,9233,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-17",24,24,1126,,0.003,0.001,542.2,0.0593,0.033,0.0072,9119.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-18",24,24,1116,,0.003,0.001,539,0.0592,0.033,0.0073,9073.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-19",24,24,1100,,0.003,0.001,535.2,0.0594,0.032,0.0071,9004.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-20",24,24,993,,0.002,0.001,480.4,0.0592,0.029,0.0071,8087.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-21",24,24,982,,0.002,0.001,473.8,0.0593,0.028,0.0071,7971.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-22",24,24,970,,0.002,0.001,470.2,0.0592,0.027,0.0068,7912.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-23",24,24,956,,0.002,0.001,468.6,0.0593,0.027,0.0068,7886.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-24",24,24,1003,,0.002,0.001,488.4,0.0591,0.029,0.007,8222.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-25",24,24,950,,0.002,0.001,474,0.0594,0.028,0.007,7971.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-26",24,24,957,,0.002,0.001,477.6,0.0593,0.029,0.0071,8034.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-27",24,24,891,,0.002,0.001,448.7,0.0594,0.026,0.007,7548.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-28",24,24,979,,0.002,0.001,484.7,0.0594,0.03,0.0073,8156.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-29",24,24,1042,,0.003,0.001,508.6,0.0593,0.029,0.0067,8555.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-11-30",24,24,1022,,0.003,0.001,501.7,0.0592,0.029,0.0069,8445.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-01",14,12.61,555.63,,0.001,0.001,271.788,0.0595,0.021,0.011,4569.332,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-02",24,24,1040,,0.003,0.001,512.7,0.0592,0.03,0.0069,8630,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-03",24,24,1148,,0.003,0.001,560.4,0.0592,0.033,0.007,9431.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-04",24,22.41,1030.49,,0.003,0.001,510.867,0.0592,0.032,0.0089,8594.977,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-05",24,24,1120,,0.003,0.001,552.1,0.0592,0.033,0.007,9291.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-06",24,24,1011,,0.003,0.001,506.2,0.0593,0.029,0.0067,8518.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-07",24,24,1005,,0.003,0.001,501.3,0.0593,0.029,0.0068,8435.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-08",24,24,1006,,0.003,0.001,501.6,0.0591,0.029,0.0068,8441,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-09",24,24,1016,,0.003,0.001,503.1,0.0594,0.028,0.0067,8459.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-10",24,24,1109,,0.003,0.001,547.4,0.0593,0.031,0.0068,9208.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-11",24,24,1137,,0.003,0.001,563.1,0.0595,0.033,0.0068,9468.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-12",24,24,1088,,0.003,0.001,541.3,0.0593,0.031,0.0067,9109.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-13",24,24,1092,,0.003,0.001,535.1,0.0592,0.031,0.0069,9005.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-14",24,24,1118,,0.003,0.001,549.4,0.0591,0.033,0.007,9247.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-15",24,24,1091,,0.003,0.001,537.9,0.0591,0.032,0.007,9055.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-16",24,24,1174,,0.003,0.001,575.4,0.0592,0.034,0.007,9686.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-17",24,24,976,,0.002,0.001,491.1,0.0593,0.027,0.0065,8263.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-18",11,9.14,413.07,,0.001,0.001,204.611,0.0589,0.022,0.0127,3446.401,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-19",24,24,1126,,0.003,0.001,558.7,0.0592,0.033,0.0069,9405.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-20",24,24,996,,0.002,0.001,493.8,0.0593,0.03,0.0072,8308.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-21",24,24,987,,0.002,0.001,489.7,0.0593,0.028,0.0069,8240.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-22",24,24,1007,,0.003,0.001,497.7,0.0592,0.029,0.0069,8375.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-23",24,24,1051,,0.003,0.001,515.7,0.0593,0.031,0.007,8675.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-24",24,24,1099,,0.003,0.001,536.1,0.0593,0.032,0.007,9018.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-25",24,24,987,,0.002,0.001,486.2,0.0593,0.027,0.0066,8181.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-26",24,24,915,,0.002,0.001,459.4,0.0592,0.025,0.0065,7732.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-27",24,24,1015,,0.003,0.001,499.4,0.0592,0.028,0.0067,8404.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-28",24,24,1097,,0.003,0.001,535.4,0.0593,0.032,0.0072,9007.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-29",24,24,1124,,0.003,0.001,548.5,0.0593,0.033,0.0071,9227.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-30",24,24,936,,0.002,0.001,471.4,0.0593,0.027,0.0068,7931.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1A",,"2020-12-31",24,24,976,,0.002,0.001,488.1,0.0591,0.029,0.007,8215.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-01",24,24,915,,0.003,0.001,495.2,0.0593,0.028,0.0068,8332.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-02",24,24,1003,,0.003,0.001,530.1,0.0592,0.031,0.0069,8918,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-03",24,24,995,,0.003,0.001,528.1,0.0592,0.029,0.0065,8888.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-04",24,24,1014,,0.003,0.001,536.9,0.0592,0.032,0.007,9035.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-05",24,24,1230,,0.003,0.001,622.5,0.0592,0.039,0.0074,10474,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-06",24,24,1020,,0.003,0.001,537.7,0.0593,0.032,0.0071,9046.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-07",24,24,1083,,0.003,0.001,563.5,0.0594,0.034,0.0071,9481.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-08",24,24,1081,,0.003,0.001,560.4,0.0593,0.034,0.0071,9430.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-09",24,24,1263,,0.003,0.001,662.3,0.0592,0.04,0.0072,11142.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-10",24,24,1241,,0.003,0.001,630.2,0.0593,0.038,0.0073,10601.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-11",24,24,1242,,0.003,0.001,628.5,0.0593,0.039,0.0074,10573.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-12",24,24,1257,,0.003,0.001,634.5,0.0593,0.038,0.0072,10676.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-13",24,24,1235,,0.003,0.001,626.6,0.0593,0.038,0.0072,10538.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-14",24,24,1238,,0.003,0.001,626.5,0.0592,0.038,0.0072,10543.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-15",24,24,1250,,0.003,0.001,630,0.0593,0.039,0.0073,10601.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-16",24,24,1116,,0.003,0.001,626.1,0.0592,0.039,0.0075,10533.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-17",24,24,1111,,0.003,0.001,629,0.0591,0.039,0.0073,10586.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-18",24,24,976,,0.003,0.001,521.1,0.0593,0.03,0.0068,8767.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-19",3,2.72,114.44,,0,0.001,60.808,0.059,0.004,0.007,1023.58,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-28",16,15.02,694,,0.002,0.0009,362.224,0.0593,0.026,0.0098,6094.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-29",24,24,1097,,0.003,0.001,569.4,0.0592,0.033,0.007,9582.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-30",24,24,1139,,0.003,0.001,590.2,0.0592,0.035,0.0069,9933.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-01-31",24,24,1191,,0.003,0.001,611,0.0593,0.036,0.007,10281.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-01",24,24,1178,,0.003,0.001,612.6,0.0591,0.035,0.0068,10308.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-02",24,24,1172,,0.003,0.001,617.6,0.0592,0.038,0.0073,10391.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-03",24,24,1164,,0.003,0.001,607.4,0.0593,0.037,0.0071,10222.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-04",24,24,1079,,0.003,0.001,560.3,0.0593,0.033,0.0071,9427.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-05",24,24,1093,,0.003,0.001,561.4,0.0593,0.033,0.007,9447.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-06",24,24,1123,,0.003,0.001,570,0.0593,0.035,0.0073,9587.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-07",24,24,1050,,0.003,0.001,537.1,0.0594,0.032,0.0071,9032.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-08",24,24,1045,,0.003,0.001,535.3,0.0592,0.032,0.007,9009.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-09",24,24,1004,,0.003,0.001,522,0.0593,0.031,0.007,8783.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-10",24,23.98,1089,,0.003,0.001,558.392,0.0593,0.033,0.007,9393.564,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-11",24,24,1225,,0.003,0.001,628.2,0.059,0.037,0.0071,10577.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-12",24,24,1011,,0.003,0.001,525.3,0.0593,0.031,0.007,8834.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-13",24,24,1124,,0.003,0.001,584.9,0.0591,0.036,0.0073,9845,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-14",18,16.78,664.2,,0.002,0.0009,363.368,0.0592,0.023,0.0071,6113.784,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-15",24,24,1009,,0.003,0.001,524.1,0.0595,0.03,0.0068,8813.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-16",2,1.37,44.4,,0,0.001,24.584,0.0595,0.001,0.0065,413.281,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-17",19,18.65,850.75,,0.002,0.001,441.55,0.0593,0.027,0.0074,7427.055,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-18",24,24,1094,,0.003,0.001,566,0.0591,0.033,0.007,9525.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-19",24,23.98,1116.96,,0.003,0.001,575.976,0.0591,0.034,0.007,9694.366,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-20",24,24,1180,,0.003,0.001,622.1,0.0592,0.038,0.0073,10468.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-21",24,24,1136,,0.003,0.001,585,0.0593,0.033,0.0068,9845.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-22",24,24,1075,,0.003,0.001,567.4,0.0592,0.034,0.007,9545.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-23",24,24,1057,,0.003,0.001,553.7,0.0593,0.033,0.0071,9315.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-24",24,24,1097,,0.003,0.001,564.2,0.0591,0.035,0.0074,9496.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-25",24,24,1188,,0.003,0.001,601,0.0591,0.036,0.0071,10113.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-26",24,24,1278,,0.003,0.001,646,0.059,0.039,0.007,10874.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-27",5,3.95,168.05,,0,0.001,88.87,0.0592,0.005,0.0074,1494.525,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-28",24,24,1074,,0.003,0.001,557,0.0592,0.033,0.007,9374.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-02-29",3,2.3,84.2,,0,0.001,45.88,0.059,0.003,0.0063,772.42,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-03",20,19.45,994.5,,0.003,0.001,501.885,0.0593,0.032,0.0091,8443.91,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-04",24,24,1049,,0.003,0.001,552,0.0593,0.034,0.0072,9289.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-05",24,24,1164,,0.003,0.001,619.1,0.0591,0.038,0.0071,10423.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-06",24,24,1008,,0.003,0.001,535.8,0.0593,0.032,0.0071,9014.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-07",24,24,1174,,0.003,0.001,627.3,0.0593,0.038,0.0073,10554.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-08",24,24,1183,,0.003,0.001,603.7,0.0592,0.037,0.0073,10158.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-09",24,24,1177,,0.003,0.001,610.6,0.0593,0.038,0.0073,10271.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-10",24,24,1233,,0.003,0.001,621.4,0.0592,0.038,0.0072,10456.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-11",24,24,1163,,0.003,0.001,596.9,0.0591,0.036,0.0071,10044.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-12",24,24,1157,,0.003,0.001,598.7,0.0592,0.036,0.0072,10073,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-13",24,24,1134,,0.003,0.001,591.7,0.0592,0.035,0.007,9957.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-14",24,24,1234,,0.003,0.001,628,0.0592,0.037,0.0071,10565.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-15",24,24,1219,,0.003,0.001,621.4,0.0592,0.038,0.0072,10458.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-16",24,24,1189,,0.003,0.001,606.3,0.0593,0.036,0.0071,10201.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-17",24,24,1126,,0.003,0.001,573.9,0.0593,0.035,0.0073,9656.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-18",24,24,1212,,0.003,0.001,606.6,0.0593,0.036,0.007,10205.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-19",24,24,1096,,0.003,0.001,561.5,0.0593,0.033,0.0069,9447.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-20",24,24,1000,,0.003,0.001,529.5,0.0592,0.03,0.0067,8911.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-21",24,24,1139,,0.003,0.001,594.6,0.059,0.037,0.0075,10007.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-22",7,5.51,230.75,,0.001,0.001,122.72,0.0591,0.008,0.0129,2064.012,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-23",24,24,990,,0.003,0.001,522.8,0.0592,0.029,0.0067,8797.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-24",24,24,1099,,0.003,0.001,567.5,0.0592,0.032,0.0067,9547.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-25",24,24,992,,0.003,0.001,528.3,0.0591,0.03,0.0067,8892.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-26",24,24,1035,,0.003,0.001,546.6,0.0594,0.03,0.0065,9194.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-27",24,24,1034,,0.003,0.001,545.4,0.0591,0.031,0.0068,9180.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-28",24,24,1110,,0.003,0.001,571.2,0.0592,0.032,0.0066,9612.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-29",24,24,1038,,0.003,0.001,544.6,0.0594,0.03,0.0065,9161.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-30",24,24,1056,,0.003,0.001,551.7,0.0592,0.032,0.0068,9285,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-03-31",24,24,964,,0.003,0.001,514.5,0.0591,0.029,0.0066,8661.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-01",24,24,1080,,0.003,0.001,562.8,0.0593,0.032,0.0068,9468,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-02",24,24,1172,,0.003,0.001,597.6,0.0592,0.036,0.0071,10054.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-03",24,24,1038,,0.003,0.001,541.6,0.0592,0.033,0.0071,9115.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-04",24,24,1085,,0.003,0.001,555.1,0.0592,0.032,0.0068,9341.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-05",24,24,1087,,0.003,0.001,554.9,0.0592,0.031,0.0066,9340.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-06",24,24,1085,,0.003,0.001,557,0.0593,0.032,0.0069,9374.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-07",24,24,988,,0.003,0.001,524.9,0.0592,0.03,0.0069,8833.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-08",24,24,1167,,0.003,0.001,599.8,0.0593,0.037,0.0073,10090,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-09",24,24,1210,,0.003,0.001,616,0.0591,0.038,0.0073,10367.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-10",24,24,1130,,0.003,0.001,583.6,0.0592,0.034,0.0069,9818.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-11",24,24,982,,0.003,0.001,525.2,0.0592,0.028,0.0062,8838.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-12",24,24,1166,,0.003,0.001,597.4,0.0592,0.035,0.0069,10053.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-13",24,24,985,,0.003,0.001,526.2,0.0591,0.029,0.0065,8853.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-14",24,24,956,,0.003,0.001,509.6,0.0593,0.028,0.0066,8576.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-15",24,24,966,,0.003,0.001,513.7,0.0593,0.03,0.0069,8640.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-16",24,24,1052,,0.003,0.001,567.3,0.0592,0.034,0.0072,9546.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-17",24,24,1098,,0.003,0.001,585.5,0.0593,0.036,0.0074,9852.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-18",24,24,1114,,0.003,0.001,590.2,0.0593,0.036,0.0072,9928.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-19",24,23.25,1072.75,,0.003,0.001,565.7,0.0592,0.034,0.0071,9520.05,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-01",3,1.9,48.34,,0,0.001,31.158,0.059,0.009,0.0423,525.053,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-08",17,16.97,676.43,,0.002,0.001,368.295,0.0592,0.025,0.0089,6196.29,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-09",24,24,941,,0.003,0.001,517.7,0.0592,0.03,0.007,8712.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-10",24,24,979,,0.003,0.001,535.1,0.0591,0.032,0.007,9005.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-11",18,17.15,671.9,,0.002,0.001,372.07,0.0594,0.022,0.0071,6257.175,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-25",10,9.58,378.54,,0.001,0.001,206.28,0.0593,0.017,0.0159,3471.226,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-26",24,24,910,,0.003,0.001,500.5,0.0593,0.029,0.0069,8421.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-27",24,24,939,,0.003,0.001,512.9,0.0593,0.031,0.0072,8628.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-28",24,24,874,,0.002,0.001,487.6,0.0592,0.029,0.0071,8207.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-29",24,24,934,,0.003,0.001,516.1,0.0591,0.029,0.0068,8685.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-30",24,24,918,,0.003,0.001,509.6,0.0593,0.029,0.0067,8577.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-05-31",24,24,959,,0.003,0.001,523.3,0.0593,0.031,0.007,8807,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-01",24,24,983,,0.003,0.001,538.7,0.0593,0.029,0.0065,9063.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-02",24,24,971,,0.003,0.001,537,0.0592,0.029,0.0065,9039.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-03",24,24,1075,,0.003,0.001,578.7,0.0592,0.033,0.0068,9738.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-04",24,24,1119,,0.003,0.001,608.8,0.0591,0.035,0.0068,10244.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-05",24,23.98,953.12,,0.003,0.001,524.114,0.0592,0.03,0.0068,8818.01,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-06",22,21.4,949.76,,0.003,0.001,518.092,0.0594,0.031,0.0071,8715.294,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-08",20,17.67,726.36,,0.002,0.001,396.248,0.0594,0.023,0.0073,6667.085,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-09",22,21.53,909.03,,0.003,0.001,499.094,0.0591,0.029,0.007,8402.289,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-10",15,14.22,628.88,,0.002,0.001,345.064,0.0593,0.02,0.0085,5804.046,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-11",24,24,930,,0.003,0.001,506.1,0.0592,0.029,0.0069,8518.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-12",24,24,924,,0.003,0.001,504.7,0.0593,0.029,0.0067,8491.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-13",24,24,900,,0.003,0.001,496.8,0.0594,0.029,0.007,8357.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-14",24,24,936,,0.003,0.001,512.1,0.0593,0.03,0.007,8613.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-15",22,21.63,862.27,,0.002,0.001,471.351,0.0592,0.028,0.0069,7932.288,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-17",13,12.57,451.41,,0.001,0.001,257.77,0.0592,0.016,0.0079,4336.265,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-18",15,13.93,544.35,,0.002,0.001,300.812,0.0592,0.015,0.0059,5063.019,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-19",3,1.76,52.48,,0,0.001,31.639,0.0593,0.002,0.0073,532.127,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-20",18,16.75,672.39,,0.002,0.001,367.755,0.0593,0.021,0.0069,6187.141,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-21",24,24,932,,0.003,0.001,516.9,0.0594,0.031,0.0071,8695.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-22",24,24,964,,0.003,0.001,527.9,0.0592,0.031,0.007,8884.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-23",24,24,1011,,0.003,0.001,551.4,0.0593,0.031,0.0068,9277.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-24",24,24,1006,,0.003,0.001,546.5,0.0593,0.032,0.007,9191.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-25",24,24,1001,,0.003,0.001,547.2,0.0591,0.032,0.0069,9210.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-26",24,24,1086,,0.003,0.001,586.3,0.0592,0.035,0.0071,9863.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-27",24,24,1051,,0.003,0.001,568.8,0.0592,0.033,0.0069,9568,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-28",24,24,992,,0.003,0.001,541.9,0.0593,0.032,0.0069,9116.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-29",3,1.77,67.62,,0,0.001,38.224,0.059,0.002,0.0077,644.264,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-06-30",24,24,963,,0.003,0.001,526.6,0.0594,0.032,0.0071,8857.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-01",24,24,998,,0.003,0.001,546.1,0.0593,0.031,0.0068,9189.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-02",24,24,950,,0.003,0.001,529.5,0.0594,0.032,0.0071,8905.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-03",24,24,1009,,0.003,0.001,553.8,0.0593,0.032,0.0068,9320.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-04",24,24,1016,,0.003,0.001,553.6,0.0593,0.032,0.0068,9316.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-05",24,23.98,1034.2,,0.003,0.001,564.058,0.0591,0.033,0.007,9495.248,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-06",22,21.72,827.44,,0.002,0.001,465.296,0.0591,0.027,0.0069,7831.744,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-07",13,12.1,507,,0.001,0.001,276.02,0.0593,0.015,0.0063,4644.92,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-08",24,24,930,,0.003,0.001,512.4,0.0592,0.03,0.007,8622.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-09",24,24,990,,0.003,0.001,541.1,0.0592,0.032,0.007,9107,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-10",24,24,1018,,0.003,0.001,554.5,0.0593,0.033,0.007,9329.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-11",24,24,1074,,0.003,0.001,578.7,0.0592,0.035,0.0071,9740.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-12",24,24,1008,,0.003,0.001,553.7,0.0593,0.032,0.0068,9315.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-13",24,24,903,,0.003,0.001,506,0.0591,0.03,0.0071,8514.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-14",24,24,891,,0.003,0.001,499.8,0.0591,0.029,0.007,8412.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-15",24,24,926,,0.003,0.001,516.9,0.0593,0.03,0.0068,8697.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-16",24,24,902,,0.003,0.001,505.4,0.0593,0.03,0.0072,8506.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-17",24,24,931,,0.003,0.001,521.3,0.0592,0.031,0.007,8775.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-18",24,24,1121,,0.003,0.001,601.9,0.0592,0.036,0.0071,10125.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-19",1,0.27,3.51,,0,0.001,2.727,0.059,0,0.005,46.089,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-22",2,1.35,37.1,,0,0.001,22.985,0.059,0.003,0.043,387.235,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-23",24,24,974,,0.003,0.001,528.6,0.0592,0.028,0.0063,8898.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-24",24,24,992,,0.003,0.001,541.3,0.0593,0.031,0.0068,9103.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-25",24,24,1010,,0.003,0.001,549.6,0.0594,0.032,0.007,9244.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-26",22,21.62,949,,0.003,0.001,512.988,0.0591,0.03,0.0069,8632.496,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-27",9,8.88,378.6,,0.001,0.001,206.596,0.0591,0.011,0.006,3479.348,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-28",24,24,910,,0.003,0.001,504.6,0.0594,0.03,0.007,8488.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-29",24,24,1049,,0.003,0.001,568.6,0.0592,0.034,0.007,9567.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-30",24,24,1019,,0.003,0.001,558.1,0.0592,0.033,0.007,9391.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-07-31",24,24,959,,0.003,0.001,525.9,0.0592,0.031,0.007,8850.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-01",24,24,989,,0.003,0.001,530.9,0.0592,0.032,0.0071,8934.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-02",24,24,992,,0.003,0.001,535.6,0.0592,0.032,0.007,9013.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-03",24,24,947,,0.003,0.001,518.9,0.0592,0.031,0.007,8733.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-04",24,24,926,,0.003,0.001,509.7,0.0594,0.03,0.007,8573.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-05",24,24,945,,0.003,0.001,515.1,0.0594,0.03,0.007,8665.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-06",24,24,957,,0.003,0.001,518.2,0.0592,0.031,0.0071,8721.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-07",24,24,908,,0.003,0.001,497.6,0.0592,0.029,0.007,8374.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-08",24,24,932,,0.003,0.001,512.5,0.0594,0.03,0.007,8621.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-09",24,24,1003,,0.003,0.001,544.9,0.0591,0.031,0.0067,9171.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-10",24,24,973,,0.003,0.001,530.3,0.0591,0.031,0.007,8925.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-11",24,24,906,,0.003,0.001,499.7,0.0593,0.03,0.0072,8409.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-12",24,24,1035,,0.003,0.001,556.7,0.0593,0.033,0.0071,9367.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-13",24,24,1127,,0.003,0.001,601.4,0.0593,0.036,0.007,10117.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-14",24,24,1176,,0.003,0.001,622.8,0.0591,0.037,0.0069,10484,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-15",24,24,1188,,0.003,0.001,623.8,0.0591,0.038,0.0072,10497.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-16",24,24,1176,,0.003,0.001,621.6,0.0591,0.037,0.007,10465,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-17",24,24,1258,,0.003,0.001,656.4,0.0592,0.039,0.007,11044.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-18",24,24,1222,,0.003,0.001,640.9,0.0593,0.039,0.0073,10780.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-19",24,24,1087,,0.003,0.001,580,0.0592,0.033,0.0068,9760.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-20",24,24,918,,0.003,0.001,507.4,0.0592,0.031,0.0073,8541.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-21",24,24,969,,0.003,0.001,527.9,0.0591,0.031,0.0069,8883.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-22",24,24,1051,,0.003,0.001,558.5,0.0592,0.033,0.0071,9398.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-23",24,24,1034,,0.003,0.001,555,0.0593,0.033,0.0071,9338.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-24",24,24,1125,,0.003,0.001,595.9,0.0593,0.036,0.0071,10026.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-25",24,24,962,,0.003,0.001,525,0.0592,0.03,0.0068,8837.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-26",24,24,935,,0.003,0.001,509.6,0.0593,0.029,0.0067,8573.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-27",10,8.32,323.54,,0.001,0.001,177.89,0.0592,0.01,0.0058,2993.468,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-28",24,24,975,,0.003,0.001,533.6,0.0593,0.031,0.0069,8975.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-29",24,24,917,,0.003,0.001,508.3,0.059,0.03,0.007,8558.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-30",24,24,941,,0.003,0.001,514.6,0.0592,0.031,0.0073,8661,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-08-31",24,24,867,,0.002,0.001,493.1,0.0593,0.03,0.0072,8292.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-01",24,24,935,,0.003,0.001,515.7,0.0592,0.03,0.007,8676.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-02",24,24,920,,0.003,0.001,509.3,0.0593,0.03,0.007,8569.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-03",24,24,952,,0.003,0.001,527.9,0.0592,0.032,0.0073,8882.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-04",24,24,1055,,0.003,0.001,567.3,0.0592,0.033,0.007,9543.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-05",24,24,1021,,0.003,0.001,561.2,0.0593,0.033,0.007,9443.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-06",24,24,1040,,0.003,0.001,569.9,0.0592,0.032,0.0068,9589.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-07",24,24,1068,,0.003,0.001,577.8,0.0592,0.033,0.0068,9722.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-08",24,24,994,,0.003,0.001,543.6,0.0592,0.032,0.0069,9146.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-09",24,24,919,,0.003,0.001,513.3,0.0592,0.031,0.0071,8639.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-10",24,24,975,,0.003,0.001,536.3,0.0593,0.032,0.007,9020.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-11",24,24,1015,,0.003,0.001,554.9,0.0591,0.032,0.0068,9340.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-12",24,24,1104,,0.003,0.001,602.6,0.0593,0.036,0.007,10137.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-13",11,10.58,437.1,,0.001,0.001,237.924,0.0591,0.014,0.0073,4004.415,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-14",24,24,981,,0.003,0.001,536.1,0.0591,0.032,0.007,9022.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-15",19,18,703.25,,0.002,0.001,386.175,0.0594,0.025,0.0102,6495.225,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-16",24,24,993,,0.003,0.001,537.2,0.0594,0.031,0.0069,9037.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-17",24,24,1043,,0.003,0.001,562.1,0.0592,0.033,0.0069,9459,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-18",24,24,1003,,0.003,0.001,544.2,0.0591,0.032,0.0069,9160.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-19",24,24,956,,0.003,0.001,527.6,0.0592,0.031,0.0069,8879.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-20",24,24,1030,,0.003,0.001,555.6,0.0592,0.032,0.0069,9350.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-21",24,24,1007,,0.003,0.001,549.7,0.0592,0.031,0.0068,9250.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-22",21,18.29,725.67,,0.002,0.001,399.446,0.0593,0.026,0.0097,6719.589,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-23",24,24,1044,,0.003,0.001,560,0.0592,0.032,0.0069,9421.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-24",24,24,941,,0.003,0.001,520.8,0.0592,0.031,0.007,8764.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-25",24,24,922,,0.003,0.001,511,0.0593,0.03,0.007,8601.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-26",24,24,954,,0.003,0.001,524.6,0.0593,0.031,0.007,8826.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-27",24,24,952,,0.003,0.001,521.6,0.0593,0.031,0.007,8776.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-28",24,24,1004,,0.003,0.001,551.1,0.0591,0.032,0.007,9274.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-29",24,24,1008,,0.003,0.001,550.1,0.0592,0.032,0.0068,9256.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-09-30",24,24,1060,,0.003,0.001,574.5,0.0593,0.034,0.007,9666.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-01",24,24,1034,,0.003,0.001,561.4,0.0593,0.032,0.0069,9444.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-02",24,24,1007,,0.003,0.001,546.8,0.0593,0.032,0.0069,9201.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-03",24,24,988,,0.003,0.001,537.5,0.0592,0.031,0.0068,9043.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-04",24,24,1005,,0.003,0.001,542.2,0.0593,0.03,0.0066,9121.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-05",24,24,1074,,0.003,0.001,563.9,0.0593,0.034,0.0072,9486.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-06",24,24,1137,,0.003,0.001,586.1,0.0592,0.036,0.0073,9862.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-07",24,24,1058,,0.003,0.001,553,0.0592,0.031,0.0067,9305.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-08",24,24,923,,0.003,0.001,495.8,0.0593,0.028,0.0066,8342,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-09",24,24,968,,0.003,0.001,511,0.0593,0.03,0.0069,8593.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-10",24,24,1007,,0.003,0.001,531.1,0.0593,0.031,0.0069,8934.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-11",24,24,1197,,0.003,0.001,620,0.0593,0.037,0.0072,10429.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-12",24,24,1203,,0.003,0.001,619.4,0.0593,0.038,0.0073,10420.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-13",24,24,1190,,0.003,0.001,614.2,0.0591,0.038,0.0074,10335.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-14",24,24,1206,,0.003,0.001,625.5,0.0593,0.038,0.0072,10521.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-15",24,24,1187,,0.003,0.001,617.1,0.0593,0.036,0.0069,10381.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-16",24,24,1033,,0.003,0.001,532.7,0.0593,0.032,0.0071,8961,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-17",24,23.98,888.32,,0.002,0.001,469.934,0.0592,0.027,0.0069,7911.348,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-18",1,0.08,0.08,,0,0.001,0.392,0.059,0,0.007,6.656,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-20",9,8.17,378.34,,0.001,0.001,203.533,0.0593,0.019,0.0348,3423.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-21",24,24,1103,,0.003,0.001,583.9,0.0592,0.034,0.007,9824.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-22",24,24,1006,,0.003,0.001,531.3,0.0593,0.031,0.0069,8941.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-23",24,24,969,,0.003,0.001,521.7,0.0593,0.03,0.0068,8776.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-24",24,24,1035,,0.003,0.001,550.8,0.0591,0.03,0.0065,9270.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-25",24,24,1096,,0.003,0.001,580.3,0.0593,0.034,0.007,9762.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-26",24,24,1099,,0.003,0.001,580.1,0.0592,0.036,0.0073,9763.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-27",24,24,1104,,0.003,0.001,583.9,0.0592,0.034,0.007,9825.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-28",24,24,1086,,0.003,0.001,573.6,0.0593,0.035,0.0072,9650.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-29",24,24,992,,0.003,0.001,534.7,0.0592,0.031,0.007,8999.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-30",24,24,1012,,0.003,0.001,544.3,0.0593,0.031,0.0068,9160.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-10-31",24,24,980,,0.003,0.001,526.1,0.0594,0.029,0.0066,8849.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-01",24,24,1057,,0.003,0.001,556.8,0.0592,0.033,0.007,9370,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-02",24,24,1152,,0.003,0.001,594.6,0.0592,0.035,0.0069,10005.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-03",24,24,1088,,0.003,0.001,568.5,0.0591,0.032,0.0066,9568,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-04",24,24,1077,,0.003,0.001,567.9,0.0593,0.033,0.0068,9554.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-05",24,24,1159,,0.003,0.001,598.2,0.0592,0.035,0.007,10065.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-06",24,24,975,,0.003,0.001,519.4,0.0591,0.029,0.0066,8742.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-07",24,24,930,,0.003,0.001,505.7,0.0592,0.029,0.0068,8513.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-08",24,24,1001,,0.003,0.001,526.2,0.0592,0.031,0.0071,8854.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-09",24,24,1040,,0.003,0.001,541.5,0.0592,0.032,0.007,9110.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-10",24,24,1017,,0.003,0.001,536.1,0.0592,0.031,0.0068,9024.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-11",24,24,969,,0.003,0.001,513.7,0.0591,0.029,0.0066,8645.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-12",24,24,978,,0.003,0.001,516.3,0.0592,0.031,0.0071,8689.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-13",24,24,976,,0.003,0.001,515.5,0.0592,0.029,0.0068,8674.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-14",24,24,969,,0.003,0.001,514.8,0.0594,0.03,0.0069,8658.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-15",2,1.15,38.75,,0,0.001,21.635,0.059,0.001,0.006,364.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-19",11,10.15,378.15,,0.001,0.001,205.005,0.0595,0.017,0.0244,3446.645,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-20",24,24,1017,,0.003,0.001,530.7,0.0592,0.031,0.0069,8929.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-21",24,24,1010,,0.003,0.001,528.4,0.0594,0.031,0.0069,8887,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-22",24,24,1019,,0.003,0.001,532.6,0.0593,0.03,0.0068,8961.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-23",24,24,992,,0.003,0.001,527.4,0.0593,0.029,0.0065,8873.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-24",24,24,1020,,0.003,0.001,539.5,0.0593,0.031,0.0067,9078.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-25",24,24,1028,,0.003,0.001,544.9,0.0595,0.033,0.0071,9162.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-26",24,24,1019,,0.003,0.001,542,0.0592,0.032,0.007,9119.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-27",24,24,969,,0.003,0.001,520,0.0594,0.03,0.007,8748.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-28",24,24,1006,,0.003,0.001,536.5,0.0594,0.032,0.0072,9022.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-29",24,24,1080,,0.003,0.001,567.3,0.0593,0.032,0.0067,9546.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-11-30",24,24,1055,,0.003,0.001,557.7,0.0594,0.033,0.007,9381.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-01",24,24,1144,,0.003,0.001,601.9,0.0591,0.035,0.007,10130.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-02",24,24,1063,,0.003,0.001,567.4,0.0591,0.034,0.0071,9550.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-03",24,24,1136,,0.003,0.001,601.3,0.0592,0.035,0.0069,10120.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-04",24,24,1098,,0.003,0.001,589.5,0.059,0.035,0.007,9923,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-05",24,24,1065,,0.003,0.001,571.5,0.0593,0.034,0.007,9614.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-06",24,24,997,,0.003,0.001,543.6,0.0593,0.03,0.0065,9146.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-07",24,24,1023,,0.003,0.001,553.6,0.0593,0.032,0.007,9314.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-08",24,24,1005,,0.003,0.001,546.2,0.0591,0.032,0.007,9195.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-09",24,24,992,,0.003,0.001,537.7,0.0592,0.03,0.0067,9048.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-10",24,24,1067,,0.003,0.001,573.4,0.0591,0.033,0.0069,9653.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-11",24,24,1130,,0.003,0.001,601.2,0.0592,0.035,0.007,10114.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-12",24,24,1110,,0.003,0.001,594.9,0.0592,0.033,0.0066,10010,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-13",24,24,1097,,0.003,0.001,581.3,0.0592,0.034,0.007,9783.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-14",24,24,1096,,0.003,0.001,585.4,0.0593,0.034,0.0069,9850.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-15",24,24,1085,,0.003,0.001,577.2,0.0592,0.033,0.0068,9714,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-16",24,24,1125,,0.003,0.001,596.5,0.059,0.035,0.007,10041.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-17",24,24,987,,0.003,0.001,538,0.0592,0.029,0.0065,9055.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-18",24,24,1172,,0.003,0.001,626.8,0.0591,0.038,0.0072,10549.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-19",12,10.17,419.17,,0.001,0.001,228.487,0.0596,0.017,0.0103,3842.324,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-20",24,24,995,,0.003,0.001,537.1,0.0592,0.033,0.0072,9040.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-21",24,24,1005,,0.003,0.001,543.7,0.0591,0.031,0.0068,9152.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-22",24,24,1035,,0.003,0.001,552.7,0.0593,0.032,0.0068,9302.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-23",24,24,1038,,0.003,0.001,556,0.0592,0.032,0.0069,9356.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-24",24,24,1084,,0.003,0.001,575.4,0.0593,0.034,0.007,9678.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-25",24,24,1025,,0.003,0.001,547.7,0.0592,0.031,0.0067,9215.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-26",24,24,964,,0.003,0.001,522.5,0.0594,0.029,0.0067,8790.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-27",24,24,1062,,0.003,0.001,565,0.0593,0.033,0.0069,9505.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-28",24,24,1097,,0.003,0.001,582.1,0.0594,0.034,0.007,9789.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-29",24,24,1134,,0.003,0.001,596.3,0.0592,0.037,0.0074,10034.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-30",24,24,1006,,0.003,0.001,544.1,0.0593,0.032,0.007,9157.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1B",,"2020-12-31",24,24,1026,,0.003,0.001,546.8,0.0593,0.032,0.0068,9201,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-05",3,2.48,102.57,,0,0.001,55.116,0.059,0.004,0.0097,928.669,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-24",6,4,66.73,,0,0.001,45.694,0.0595,0.007,0.0272,767.714,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-03",4,2.63,48.53,,0,0.001,32.196,0.06,0.006,0.0278,540.309,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-06",3,1.74,30.46,,0,0.001,20.549,0.0593,0.004,0.0277,345.887,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-13",19,18.55,830.15,,0.002,0.001,437.21,0.0592,0.033,0.0097,7355.13,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-14",1,0.08,0,,0,0.001,0.392,0.059,0,0.009,6.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-25",7,6.12,238.32,,0.001,0.001,127.792,0.0593,0.011,0.0173,2148.396,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-26",21,18.47,646.15,,0.002,0.001,353.747,0.0592,0.027,0.0124,5954.631,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-04",3,1.75,61.68,,0,0.001,34.296,0.0597,0.005,0.0167,576.662,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-06",8,6.17,148,,0,0.001,89.624,0.0594,0.008,0.019,1508.478,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-09",15,13.13,566,,0.002,0.001,302.727,0.0595,0.024,0.0109,5090.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-16",18,17.58,754.3,,0.002,0.001,398.678,0.0592,0.024,0.0074,6712.322,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-17",1,0.23,3.68,,0,0.001,2.622,0.059,0,0.006,44.16,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-20",8,6.43,256.5,,0.001,0.001,135.882,0.0595,0.014,0.0108,2286.142,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-21",6,4.77,169.5,,0,0.001,91.925,0.0593,0.01,0.0138,1547.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-28",4,2.88,119.96,,0,0.001,63.204,0.0593,0.004,0.009,1062.98,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-01",3,2.05,77.51,,0,0.001,42.346,0.059,0.005,0.0203,713.946,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-26",8,7.2,317.75,,0.001,0.001,173,0.0591,0.011,0.008,2911.501,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-27",6,5.22,176.54,,0.001,0.001,100.626,0.0593,0.009,0.0122,1693.216,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-03",5,4.3,180.05,,0.001,0.001,99.36,0.059,0.009,0.0112,1672.619,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-04",6,5,202.6,,0.001,0.001,112.82,0.0595,0.011,0.0137,1898.48,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-06",2,1.3,26.5,,0,0.001,16.865,0.0595,0.004,0.0225,283.035,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-09",4,3.03,128.05,,0,0.001,69.844,0.059,0.006,0.0128,1176.002,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-10",10,8.15,347,,0.001,0.001,190.695,0.0595,0.013,0.0121,3208.052,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-19",9,8.03,194.9,,0.001,0.001,119.36,0.0591,0.015,0.0148,2010.307,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-26",7,6.35,271.3,,0.001,0.001,148.705,0.0593,0.01,0.0091,2501.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-01",8,7.18,227.63,,0.001,0.001,130.266,0.0591,0.01,0.0161,2192.311,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-10",6,4.83,186.15,,0.001,0.001,101.966,0.0595,0.007,0.0088,1715.751,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-11",6,4.89,201.27,,0.001,0.001,110.452,0.0597,0.009,0.0148,1856.544,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-12",5,3.78,156.67,,0,0.001,85.171,0.0592,0.009,0.0142,1434.822,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-26",7,5.84,257.84,,0.001,0.001,139.302,0.0591,0.012,0.0207,2345.464,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-27",10,8.97,312.96,,0.001,0.001,174.928,0.0591,0.011,0.0108,2945.034,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-29",4,3.03,124.77,,0,0.001,68.495,0.059,0.007,0.0148,1154.144,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-30",5,4.45,196.84,,0.001,0.001,107.783,0.0594,0.008,0.013,1812.046,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-09",4,3.8,131.2,,0,0.001,74.095,0.0593,0.006,0.0105,1246.575,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-13",11,9.6,411.15,,0.001,0.001,221.704,0.0594,0.015,0.0108,3731.773,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-14",11,10.62,476.22,,0.001,0.001,254.212,0.059,0.017,0.009,4280.116,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-15",13,11.8,547.7,,0.001,0.001,293.44,0.0593,0.021,0.0155,4936.29,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-16",15,14.1,643.95,,0.002,0.001,345.581,0.0591,0.024,0.0118,5819.564,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-17",15,12.89,594.95,,0.002,0.001,321.647,0.0594,0.022,0.009,5410.528,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-18",13,12.4,533.6,,0.001,0.001,290.145,0.0593,0.019,0.0082,4882.27,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-19",11,9.68,424.46,,0.001,0.001,230.21,0.0594,0.015,0.0127,3871.028,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-24",3,1.73,69.05,,0,0.001,37.653,0.0593,0.004,0.012,634.051,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-28",4,2.41,100.59,,0,0.001,54.58,0.0593,0.005,0.0205,918.154,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-04",2,1.34,41.12,,0,0.001,23.841,0.0595,0.004,0.014,401.06,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-05",10,8.9,371.4,,0.001,0.001,202.678,0.0592,0.014,0.0175,3411.62,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-06",8,7.41,326.71,,0.001,0.001,175.056,0.0594,0.015,0.0114,2944.912,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-12",3,1.34,25.31,,0,0.001,16.776,0.0593,0.005,0.0507,282.159,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-16",16,14.16,393.91,,0.001,0.0009,232.335,0.0595,0.018,0.0131,3905.284,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-17",7,5.22,225.04,,0.001,0.001,122.33,0.0593,0.01,0.0177,2056.552,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-18",4,2.95,113.3,,0,0.001,62.597,0.059,0.007,0.014,1054.085,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-19",3,2,78.85,,0,0.001,43.411,0.0593,0.004,0.0153,730.373,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-20",3,2.5,100.99,,0,0.001,55.629,0.0597,0.006,0.014,934.743,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-21",4,3.49,85.89,,0,0.001,52.482,0.0595,0.005,0.0105,882.399,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-27",5,4.07,165.14,,0,0.001,89.743,0.059,0.008,0.019,1510.71,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-28",6,4.82,200.75,,0.001,0.001,109.133,0.059,0.007,0.0087,1837.111,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-29",4,2.95,119.2,,0,0.001,65.164,0.0593,0.005,0.0105,1097.091,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-09-30",5,4.26,188,,0.001,0.001,101.976,0.0592,0.007,0.0098,1715.514,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-01",2,1.88,77.08,,0,0.001,42.112,0.059,0.004,0.0105,708.98,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-02",3,2.16,81.47,,0,0.001,45.301,0.059,0.005,0.0127,763.684,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-04",7,6,217.05,,0.001,0.0009,119.71,0.0593,0.008,0.011,2012.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-05",9,8.07,346.56,,0.001,0.001,183.186,0.0592,0.014,0.011,3082.47,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-06",3,2.49,88.62,,0,0.001,48.383,0.059,0.005,0.0123,813.936,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-14",6,4.4,180.3,,0,0.001,96.35,0.0592,0.008,0.015,1621.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-15",4,3.32,99.33,,0,0.001,56.543,0.059,0.005,0.0095,952.066,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-16",2,1.59,43.47,,0,0.001,25.524,0.059,0.004,0.021,429.871,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-04",2,1.78,65.08,,0,0.001,34.91,0.059,0.005,0.0195,588.04,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-15",5,3.28,133.22,,0,0.001,70.694,0.0592,0.004,0.019,1189.098,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-24",2,1.38,25.36,,0,0.001,16.526,0.0595,0.003,0.0275,278.157,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-18",9,7.13,139.1,,0,0.001,90.967,0.0593,0.016,0.02,1530.28,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-19",5,3.64,128.02,,0,0.001,71.715,0.059,0.007,0.0208,1206.732,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Procter and Gamble Power Plant",7551,"1C",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-01",24,24,2777,,0.006,0.001,1237.8,0.059,0.104,0.01,20828.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-02",24,24,2968,,0.007,0.001,1304.4,0.059,0.11,0.01,21949.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-03",24,24,2956,,0.007,0.001,1300.5,0.059,0.109,0.01,21882,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-04",24,24,2808,,0.006,0.001,1250.2,0.059,0.105,0.01,21039.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-05",24,24,3059,,0.007,0.001,1337.2,0.059,0.113,0.01,22502.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-06",24,24,2846,,0.006,0.001,1264.6,0.059,0.106,0.01,21281,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-07",24,24,2788,,0.006,0.001,1245,0.059,0.105,0.01,20950.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-08",24,24,3053,,0.007,0.001,1332.5,0.059,0.112,0.01,22421.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-09",24,24,3198,,0.007,0.001,1381.4,0.059,0.114,0.0098,23243,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-10",24,24,3400,,0.007,0.001,1453.3,0.059,0.122,0.01,24455.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-11",24,24,2787,,0.006,0.001,1241.9,0.059,0.104,0.01,20893.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-12",24,24,2797,,0.006,0.001,1245.6,0.059,0.105,0.01,20963.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-13",24,24,3017,,0.007,0.001,1321,0.059,0.111,0.01,22227.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-14",24,24,2882,,0.006,0.001,1274.2,0.059,0.107,0.01,21438.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-15",24,24,3167,,0.007,0.001,1372.6,0.059,0.115,0.01,23097,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-16",24,24,3325,,0.007,0.001,1422.1,0.059,0.116,0.0097,23933.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-17",24,24,3425,,0.007,0.001,1459.7,0.059,0.111,0.009,24564.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-18",24,24,3186,,0.007,0.001,1377.2,0.059,0.104,0.009,23172.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-19",24,24,3501,,0.008,0.001,1486.2,0.059,0.114,0.0091,25006.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-20",24,24,3521,,0.008,0.001,1490.9,0.059,0.114,0.0091,25081.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-21",24,24,3153,,0.007,0.001,1363.5,0.059,0.103,0.009,22946,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-22",24,24,3127,,0.007,0.001,1355.5,0.059,0.103,0.009,22807.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-23",24,24,3290,,0.007,0.001,1412.3,0.059,0.107,0.009,23760.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-24",24,24,3261,,0.007,0.001,1400.7,0.059,0.106,0.009,23569.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-25",24,24,3346,,0.007,0.001,1431.7,0.059,0.109,0.009,24092.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-26",24,24,3095,,0.007,0.001,1344.3,0.059,0.102,0.009,22619.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-27",24,24,3177,,0.007,0.001,1375.6,0.059,0.106,0.0091,23146.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-28",24,24,3325,,0.007,0.001,1431.5,0.059,0.107,0.0089,24091,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-29",24,23.92,3097.76,,0.007,0.001,1347.432,0.059,0.107,0.0096,22672.724,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-02",1,0.97,73.72,,0,0.001,36.86,0.06,0.052,0.169,619.442,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-03",24,24,3276,,0.007,0.001,1411.4,0.059,0.107,0.009,23746.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-04",24,24,3193,,0.007,0.001,1382.4,0.059,0.106,0.0091,23258.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-05",1,0.08,3.12,,0,0.001,1.96,0.059,0.003,0.182,33.024,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-12",23,22.86,2924.62,,0.006,0.001,1275.446,0.059,0.147,0.016,21462.92,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-26",19,18.88,2466.48,,0.005,0.001,1071.944,0.059,0.127,0.0179,18035.376,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-27",2,1.92,201.08,,0,0.001,91.936,0.059,0.012,0.016,1547.988,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-06",24,23.65,2804.05,,0.006,0.001,1241.205,0.059,0.136,0.0186,20887.29,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-07",24,24,3275,,0.007,0.001,1407.2,0.059,0.107,0.009,23677.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-08",24,24,3204,,0.007,0.001,1381.2,0.059,0.105,0.009,23242.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-09",24,24,3089,,0.007,0.001,1344.2,0.059,0.102,0.009,22624,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-10",24,24,3781,,0.008,0.001,1587,0.059,0.123,0.0092,26700.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-11",24,24,3346,,0.007,0.001,1432.1,0.059,0.109,0.009,24095.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-12",24,24,3526,,0.008,0.001,1494.7,0.059,0.114,0.009,25154,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-13",24,24,3597,,0.008,0.001,1524.1,0.059,0.116,0.009,25646.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-14",24,24,3442,,0.007,0.001,1464.3,0.059,0.111,0.009,24641.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-15",23,22.9,3166.4,,0.007,0.001,1356.85,0.059,0.108,0.0096,22828.19,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-26",15,13.86,1607.04,,0.004,0.001,715.445,0.0591,0.116,0.0291,12035.341,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-27",24,24,3533,,0.008,0.001,1493.9,0.059,0.114,0.009,25140.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-28",24,24,3665,,0.008,0.001,1541.2,0.059,0.117,0.009,25930.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-29",24,24,3645,,0.008,0.001,1534.7,0.059,0.116,0.009,25825.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-30",24,24,3547,,0.008,0.001,1503.7,0.059,0.114,0.009,25304.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-03-31",24,24,3382,,0.007,0.001,1444.7,0.059,0.11,0.009,24311.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-01",24,24,3003,,0.007,0.001,1313.2,0.059,0.099,0.009,22101.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-02",24,24,3455,,0.007,0.001,1468.5,0.059,0.111,0.009,24710.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-03",24,24,3634,,0.008,0.001,1531.5,0.059,0.117,0.009,25774,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-04",24,24,3623,,0.008,0.001,1529.1,0.059,0.116,0.009,25726.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-05",24,24,3569,,0.008,0.001,1508,0.059,0.114,0.009,25376.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-06",24,24,3445,,0.007,0.001,1464.6,0.059,0.111,0.009,24644.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-07",24,24,3421,,0.007,0.001,1455.4,0.059,0.11,0.009,24491.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-08",24,24,3726,,0.008,0.001,1560.6,0.059,0.118,0.009,26258.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-09",24,24,3753,,0.008,0.001,1571.2,0.059,0.119,0.009,26442,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-10",24,24,3169,,0.007,0.001,1369.9,0.059,0.104,0.009,23056.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-11",24,24,2929,,0.006,0.001,1286.9,0.059,0.098,0.009,21656.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-12",24,24,3341,,0.007,0.001,1431,0.059,0.109,0.0091,24082.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-13",24,24,2799,,0.006,0.001,1242.9,0.059,0.094,0.009,20913.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-14",24,24,2983,,0.007,0.001,1305,0.059,0.099,0.009,21959.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-15",24,24,2836,,0.006,0.001,1253.9,0.059,0.095,0.009,21096.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-16",24,24,3053,,0.007,0.001,1330.5,0.059,0.101,0.009,22387.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-17",24,24,2843,,0.006,0.001,1255.6,0.059,0.095,0.009,21123.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-18",24,24,2866,,0.006,0.001,1263.6,0.059,0.096,0.009,21264.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-19",24,24,2831,,0.006,0.001,1253.8,0.059,0.095,0.009,21098.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-20",24,24,3034,,0.007,0.001,1323.7,0.059,0.1,0.009,22279.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-21",24,24,2923,,0.006,0.001,1285.8,0.059,0.097,0.009,21640.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-22",22,21.9,2646.3,,0.006,0.001,1165.2,0.059,0.093,0.0095,19605.63,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-07",15,14.98,1824.5,,0.004,0.001,799.154,0.059,0.104,0.0183,13449.934,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-08",24,23.9,2795,,0.006,0.001,1235.44,0.059,0.098,0.0095,20791.71,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-25",15,14.93,1964.89,,0.004,0.001,848.631,0.059,0.104,0.0182,14280.568,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-26",24,24,3215,,0.007,0.001,1401.7,0.059,0.107,0.009,23585,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-27",24,24,3356,,0.007,0.001,1454.4,0.059,0.11,0.009,24474.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-28",24,24,2751,,0.006,0.001,1218.9,0.059,0.092,0.009,20508.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-29",19,18.23,2238.41,,0.005,0.001,981.512,0.059,0.078,0.0117,16519.316,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-01",18,17.97,2095.75,,0.005,0.001,926.375,0.059,0.108,0.0158,15586.179,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-02",24,24,2944,,0.007,0.001,1289,0.059,0.098,0.009,21691.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-03",24,24,3458,,0.008,0.001,1493,0.059,0.112,0.0089,25121.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-04",24,24,3624,,0.008,0.001,1545,0.059,0.118,0.009,25995.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-05",1,0.87,85.26,,0,0.001,39.237,0.059,0.008,0.023,659.808,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-19",15,14.97,1860.78,,0.004,0.001,811.384,0.059,0.099,0.0172,13653.535,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-20",24,24,2882,,0.006,0.001,1266.2,0.059,0.096,0.009,21308,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-21",24,24,2852,,0.006,0.001,1255.6,0.059,0.095,0.009,21125.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-22",24,24,2944,,0.007,0.001,1287.6,0.059,0.098,0.009,21666,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-23",24,24,3338,,0.007,0.001,1422.7,0.059,0.108,0.009,23933,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-24",24,24,3108,,0.007,0.001,1343,0.059,0.102,0.009,22596.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-25",24,24,3026,,0.007,0.001,1316,0.059,0.1,0.009,22142.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-26",24,24,3323,,0.007,0.001,1419.9,0.059,0.109,0.0091,23895.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-27",1,0.98,123.48,,0,0.001,53.704,0.059,0.009,0.019,903.952,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-10",17,16.97,2276.78,,0.005,0.001,988.387,0.059,0.113,0.0164,16631.247,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-11",24,24,3357,,0.007,0.001,1438,0.059,0.109,0.009,24197.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-12",24,24,3169,,0.007,0.001,1374.4,0.059,0.104,0.009,23122.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-13",24,23.35,2689.7,,0.006,0.001,1190.455,0.059,0.094,0.0105,20031.335,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-26",17,16.98,2452.52,,0.005,0.001,1055.556,0.059,0.116,0.016,17764.076,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-27",24,24,3078,,0.007,0.001,1333,0.059,0.101,0.009,22429.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-28",24,24,2945,,0.006,0.001,1285.2,0.059,0.097,0.009,21628.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-29",24,24,3110,,0.007,0.001,1350.6,0.059,0.102,0.009,22728.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-30",24,24,3163,,0.007,0.001,1375.9,0.059,0.102,0.0089,23150.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-07-31",24,24,2851,,0.006,0.001,1256.1,0.059,0.095,0.009,21137.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-01",24,24,2811,,0.006,0.001,1244.1,0.059,0.094,0.009,20933.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-02",24,24,2812,,0.006,0.001,1243.9,0.059,0.094,0.009,20927.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-03",24,24,2788,,0.006,0.001,1234.5,0.059,0.093,0.009,20775,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-04",24,24,2724,,0.006,0.001,1213,0.059,0.092,0.009,20416.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-05",24,24,2743,,0.006,0.001,1221.6,0.059,0.092,0.009,20550.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-06",24,24,2746,,0.006,0.001,1220.9,0.059,0.092,0.009,20539.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-07",24,24,2813,,0.006,0.001,1243.9,0.059,0.094,0.009,20927.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-08",24,24,2795,,0.006,0.001,1235.2,0.059,0.094,0.009,20782,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-09",24,24,3005,,0.007,0.001,1314.9,0.059,0.1,0.009,22124,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-10",24,24,2826,,0.006,0.001,1247.9,0.059,0.094,0.009,20999.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-11",24,24,2743,,0.006,0.001,1220.4,0.059,0.092,0.009,20535.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-12",24,24,3082,,0.007,0.001,1339.5,0.059,0.101,0.009,22540.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-13",24,24,3980,,0.009,0.001,1703.8,0.059,0.129,0.009,28669.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-14",24,24,3553,,0.008,0.001,1532.9,0.059,0.116,0.009,25792.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-15",24,24,3885,,0.008,0.001,1660,0.059,0.126,0.009,27936.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-16",24,24,3953,,0.009,0.001,1683.9,0.059,0.127,0.009,28332.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-17",24,24,4221,,0.009,0.001,1784,0.059,0.135,0.009,30016.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-18",24,24,3972,,0.009,0.001,1691.6,0.059,0.128,0.009,28463.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-19",24,23.98,3488.76,,0.008,0.001,1519.5,0.059,0.116,0.009,25565.386,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-20",24,24,2722,,0.006,0.001,1213.1,0.059,0.092,0.009,20410.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-21",24,24,2937,,0.007,0.001,1290.9,0.059,0.098,0.009,21717.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-22",24,24,3182,,0.007,0.001,1376.7,0.059,0.104,0.009,23166.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-23",24,24,3187,,0.007,0.001,1379.3,0.059,0.104,0.009,23206,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-24",24,24,3441,,0.007,0.001,1473.6,0.059,0.112,0.009,24796.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-25",24,24,2857,,0.006,0.001,1261.7,0.059,0.096,0.009,21233.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-26",24,24,2790,,0.006,0.001,1236.6,0.059,0.094,0.009,20807.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-27",24,24,2791,,0.006,0.001,1239,0.059,0.094,0.009,20849.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-28",24,24,2870,,0.006,0.001,1263.7,0.059,0.096,0.009,21263.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-29",24,24,2773,,0.006,0.001,1231.6,0.059,0.093,0.009,20725.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-30",24,23.98,2719.72,,0.006,0.001,1230.284,0.059,0.093,0.009,20704.596,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-08-31",24,24,2696,,0.006,0.001,1205.1,0.059,0.091,0.009,20278.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-01",24,24,2773,,0.006,0.001,1233.6,0.059,0.093,0.009,20753.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-02",24,24,2711,,0.006,0.001,1212.5,0.059,0.092,0.009,20402.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-03",24,24,2974,,0.007,0.001,1305.2,0.059,0.099,0.009,21959.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-04",24,24,3228,,0.007,0.001,1393.1,0.059,0.105,0.009,23444,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-05",24,24,3307,,0.007,0.001,1437.9,0.059,0.109,0.009,24195.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-06",24,24,3576,,0.008,0.001,1541.6,0.059,0.117,0.009,25937,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-07",24,24,3891,,0.008,0.001,1649.6,0.059,0.125,0.009,27758.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-08",24,24,3055,,0.007,0.001,1326.4,0.059,0.1,0.009,22320.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-09",24,24,2734,,0.006,0.001,1214.9,0.059,0.092,0.009,20440.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-10",24,24,2982,,0.007,0.001,1305.6,0.059,0.099,0.009,21968.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-11",24,24,2933,,0.007,0.001,1288,0.059,0.098,0.009,21672.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-12",24,24,2906,,0.006,0.001,1279.1,0.059,0.097,0.009,21524.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-13",24,24,2864,,0.006,0.001,1264.3,0.059,0.096,0.009,21274.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-14",24,23.97,2945.94,,0.007,0.001,1294.502,0.059,0.103,0.0095,21784.08,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-27",19,18.02,2045,,0.005,0.0009,912.502,0.058,0.103,0.0143,15352.65,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-28",24,24,2688,,0.006,0.001,1200.4,0.059,0.091,0.009,20202.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-29",24,24,3329,,0.007,0.001,1448.8,0.059,0.11,0.009,24381,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-09-30",24,24,3540,,0.008,0.001,1521.5,0.059,0.116,0.009,25604.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-01",24,24,3280,,0.007,0.001,1422.7,0.059,0.108,0.009,23940.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-02",24,24,3005,,0.007,0.001,1312,0.059,0.099,0.009,22078,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-03",24,24,2912,,0.006,0.001,1281.4,0.059,0.097,0.009,21565.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-04",24,24,3168,,0.007,0.001,1374,0.059,0.105,0.009,23119.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-05",24,24,3548,,0.008,0.001,1515,0.059,0.115,0.009,25492,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-06",24,24,3540,,0.008,0.001,1519.7,0.059,0.115,0.009,25573.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-07",24,24,3209,,0.007,0.001,1390.5,0.059,0.106,0.009,23400.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-08",23,23,2704,,0.006,0.001,1203.1,0.059,0.096,0.0095,20243.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-14",15,14.45,1977.25,,0.004,0.001,853.785,0.059,0.105,0.0253,14362.895,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-15",24,24,3479,,0.008,0.001,1490.5,0.059,0.113,0.009,25080.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-16",23,22.92,2966.84,,0.007,0.001,1296.348,0.059,0.103,0.0095,21814.448,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-10",16,15.8,2018.6,,0.004,0.001,881.6,0.059,0.088,0.0145,14836.58,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-11",24,24,2901,,0.006,0.001,1279.3,0.059,0.097,0.009,21525,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-12",24,24,3098,,0.007,0.001,1350.1,0.059,0.102,0.009,22716.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-13",24,22.23,2730.14,,0.006,0.001,1200.775,0.059,0.124,0.0169,20205.119,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-14",16,15.95,1704.7,,0.004,0.001,777.428,0.059,0.1,0.0171,13081.904,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-15",24,24,3109,,0.007,0.001,1359.9,0.059,0.103,0.009,22881.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-16",24,24,2990,,0.007,0.001,1310.7,0.059,0.1,0.0091,22051.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-17",24,24,3008,,0.007,0.001,1314.2,0.059,0.1,0.009,22112.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-18",24,24,2867,,0.006,0.001,1265.8,0.059,0.096,0.009,21299.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-19",24,24,2902,,0.006,0.001,1280.1,0.059,0.097,0.009,21541.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-20",24,24,3118,,0.007,0.001,1356,0.059,0.103,0.009,22815.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-21",24,24,3423,,0.007,0.001,1460.5,0.059,0.111,0.009,24572.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-22",24,24,3564,,0.008,0.001,1506.3,0.059,0.114,0.009,25346.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-23",24,24,3528,,0.008,0.001,1491.5,0.059,0.113,0.009,25095.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-24",10,9.93,1217,,0.003,0.001,534.166,0.059,0.045,0.0103,8988.81,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-04",18,17.97,2488.78,,0.005,0.001,1076.381,0.059,0.13,0.0178,18112.593,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-05",24,24,3499,,0.007,0.001,1482.2,0.059,0.112,0.009,24945,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-06",24,24,3172,,0.007,0.001,1372.2,0.059,0.104,0.009,23089.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-07",24,24,3283,,0.007,0.001,1410.2,0.059,0.107,0.009,23725.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-08",24,24,3290,,0.007,0.001,1412.4,0.059,0.107,0.009,23767.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-09",24,24,3728,,0.008,0.001,1578.1,0.059,0.125,0.0094,26557.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-10",24,24,3458,,0.007,0.001,1469.6,0.059,0.12,0.0097,24730.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-11",24,24,3603,,0.008,0.001,1533.4,0.059,0.121,0.0094,25806.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-12",24,24,3485,,0.008,0.001,1492,0.059,0.119,0.0095,25102.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-13",24,24,3515,,0.008,0.001,1491.8,0.059,0.121,0.0096,25100.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-14",24,24,3580,,0.008,0.001,1521.6,0.059,0.126,0.0098,25603.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-15",24,24,3621,,0.008,0.001,1535.8,0.059,0.125,0.0096,25844.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-16",24,24,3719,,0.008,0.001,1573.5,0.059,0.127,0.0096,26471.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-17",24,24,2972,,0.007,0.001,1302.3,0.059,0.104,0.0095,21915.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-18",24,24,3231,,0.007,0.001,1393.3,0.059,0.112,0.0095,23447.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-19",24,24,3070,,0.007,0.001,1339.6,0.059,0.105,0.0093,22541.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-20",24,24,3144,,0.007,0.001,1365.6,0.059,0.109,0.0095,22981.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-21",24,24,3057,,0.007,0.001,1334.5,0.059,0.108,0.0096,22458.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-22",24,24,3140,,0.007,0.001,1361.2,0.059,0.112,0.0098,22910.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-23",24,24,3362,,0.007,0.001,1441.7,0.059,0.114,0.0094,24259.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-24",24,24,3413,,0.007,0.001,1459.7,0.059,0.116,0.0094,24561,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-25",24,24,2994,,0.007,0.001,1311.7,0.059,0.108,0.0098,22072.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-26",24,24,2843,,0.006,0.001,1260.2,0.059,0.099,0.0094,21206.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-27",24,24,3388,,0.007,0.001,1445.5,0.059,0.117,0.0096,24324.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-28",24,24,3581,,0.008,0.001,1513.6,0.059,0.123,0.0097,25470.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-29",24,24,3462,,0.007,0.001,1472.4,0.059,0.121,0.0098,24778.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-30",24,24,2986,,0.007,0.001,1310.4,0.059,0.108,0.0098,22054,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Campbell Power Plant",7552,"1",,"2020-12-31",24,24,3182,,0.007,0.001,1381.1,0.059,0.11,0.0095,23238.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-25",12,11.72,450.08,,0.001,0.0009,262.656,0.0593,0.047,0.0259,4418.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-26",19,18.1,714,,0.002,0.001,409.53,0.0591,0.066,0.0198,6891.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-25",12,9.91,403.84,,0.001,0.0003,235.066,0.0591,0.042,0.0195,3952.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-26",5,3.18,88.24,,0,0.001,55.882,0.0598,0.013,0.0268,938.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-26",19,18.57,819.66,,0.003,0.001,465.269,0.0592,0.074,0.0189,7829.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-27",24,23.12,1010.12,,0.003,0.001,576.644,0.0593,0.092,0.0191,9700.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-04",1,0.2,0,,0,0.001,1.06,0.059,0.001,0.074,17.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-15",1,0.3,0,,0,0.001,1.71,0.06,0,0.018,28.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-03",6,4.35,113.01,,0,0.0008,73.718,0.0595,0.014,0.0223,1240.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-04",10,8.18,265.2,,0.001,0.001,161.012,0.0591,0.032,0.0241,2709.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-07",8,6.6,223.83,,0.001,0.001,136.007,0.0594,0.026,0.0293,2290.279,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-10",8,7,259.49,,0.001,0.0006,154.318,0.0593,0.031,0.021,2596.781,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-11",9,8.02,270.89,,0.001,0.001,163.531,0.059,0.03,0.022,2752.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-12",10,8.08,291.12,,0.001,0.0009,171.507,0.0591,0.031,0.0192,2890.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-13",9,7.05,242,,0.001,0.0008,145.253,0.0594,0.027,0.0191,2443.963,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-30",6,4.76,164.79,,0,0.0008,98.117,0.059,0.019,0.0223,1652.619,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-07-31",9,8.07,297.07,,0.001,0.0009,175.908,0.0594,0.03,0.0201,2957.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-03",8,6.72,182.9,,0.001,0.0009,118.592,0.0591,0.022,0.0206,1993.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-13",11,9.08,313.09,,0.001,0.0008,187.311,0.0593,0.033,0.0188,3150.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-14",10,8.93,335.82,,0.001,0.0009,198.344,0.059,0.035,0.0204,3340.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-15",12,11.02,446.37,,0.001,0.0009,260.302,0.0593,0.043,0.0196,4380.153,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-16",13,11.15,428.96,,0.001,0.0008,252.183,0.0594,0.041,0.0192,4243.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-17",13,12.15,502.51,,0.002,0.0009,289.355,0.0591,0.05,0.0204,4871.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-18",14,12.16,458.52,,0.001,0.0006,271.34,0.0594,0.054,0.0219,4565.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-19",15,13.2,518.36,,0.002,0.0008,302.968,0.0592,0.051,0.0204,5098.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-20",14,12.44,506.48,,0.002,0.0007,293.672,0.0594,0.05,0.024,4940.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-21",12,9.95,401.76,,0.001,0.0003,233.461,0.0596,0.042,0.0221,3930.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-22",10,8.32,294.4,,0.001,0.0009,178.168,0.0593,0.029,0.0224,2997.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-23",11,9.28,373.64,,0.001,0.0008,217.372,0.0591,0.037,0.021,3657.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-24",9,6.31,226.8,,0.001,0.0008,135.739,0.0573,0.022,0.019,2285.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-25",9,7.38,291.58,,0.001,0.0008,170.9,0.0591,0.03,0.0243,2877.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-26",10,8.11,313,,0.001,0.0004,184.661,0.0591,0.038,0.0233,3106.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-27",7,4.56,123.23,,0,0.0009,79.81,0.0594,0.017,0.0247,1342.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-28",8,6.13,214,,0.001,0.0009,129.425,0.0594,0.023,0.0204,2176.597,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-05",13,12.55,520.25,,0.001,0.0006,302.57,0.0592,0.053,0.0222,5090.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-06",23,22.12,822.12,,0.002,0.0008,494.62,0.0592,0.08,0.0199,8324.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-07",13,11.17,419.12,,0.001,0.0009,252.642,0.0593,0.043,0.0199,4250.357,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-08",13,10.71,396.74,,0.001,0.0008,237.227,0.0599,0.04,0.0215,3994.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-09",7,5.18,199.52,,0.001,0.001,117.251,0.0593,0.021,0.0223,1972.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-10",9,7.13,277,,0.001,0.0009,163.84,0.0596,0.029,0.0204,2755.611,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-11",10,8.15,315.12,,0.001,0.0008,185.585,0.0591,0.034,0.0206,3123.182,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-12",8,6.46,197.45,,0.001,0.0008,123.547,0.0596,0.027,0.0308,2077.509,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-13",9,7.15,276.12,,0.001,0.0009,163.452,0.0593,0.028,0.0198,2749.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-14",12,8.91,310.91,,0.001,0.0008,186.608,0.0595,0.057,0.04,3138.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-17",2,0.93,25.64,,0,0.001,16.82,0.059,0.011,0.0735,283.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-18",2,0.6,8.22,,0,0.0005,7.003,0.0595,0.004,0.066,118.141,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-09-30",6,4.52,181.5,,0.001,0.0005,104.058,0.0602,0.017,0.02,1751.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-01",24,23.12,914.12,,0.003,0.0008,532.72,0.0593,0.085,0.0197,8959.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-02",6,5.59,201.69,,0.001,0.001,118.626,0.0593,0.023,0.0255,1995.329,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-12",2,0.25,0,,0,0.001,1.388,0.059,0.001,0.053,23.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-15",6,4.15,133.12,,0,0.0008,81.458,0.0592,0.018,0.0273,1371.363,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-12",1,0.2,0,,0,0.001,1.16,0.06,0.001,0.09,19.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-19",2,0.6,0,,0,0.0005,3.66,0.056,0.001,0.018,62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-20",6,4.29,82.27,,0,0.0003,59.7,0.0593,0.011,0.0245,1004.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-02",3,0.29,2.53,,0,0.0003,2.56,0.059,0.003,0.043,43.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lake",7987,"01",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-06",1,0.68,11.56,,0,0.001,11.356,0.059,0.011,0.11,191.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-07",19,18.55,1761.9,,0.004,0.001,876.885,0.059,0.191,0.0306,14755.005,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-03",15,12.74,1132.98,,0.003,0.001,569.587,0.0592,0.195,0.0711,9582.945,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-04",7,5.96,502.96,,0.001,0.001,256.24,0.059,0.119,0.084,4311.548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-05",17,13.17,1247.83,,0.003,0.0009,619.443,0.059,0.156,0.0524,10424.152,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-06",7,6.04,546.13,,0.001,0.001,274.386,0.059,0.078,0.0617,4616.907,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-16",7,4.55,159.74,,0.001,0.001,107.458,0.0594,0.142,0.1463,1808.131,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-17",13,11.63,1060.3,,0.003,0.001,530.415,0.0592,0.15,0.0557,8923.719,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-18",14,10.25,859.27,,0.002,0.001,437.719,0.0591,0.158,0.0729,7366.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-19",12,10.99,1074.36,,0.003,0.001,528.658,0.0591,0.098,0.0272,8896.095,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-18",10,7.88,582.24,,0.002,0.001,303.298,0.0591,0.204,0.0984,5105.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-19",3,2.38,226.98,,0.001,0.001,111.436,0.059,0.019,0.03,1875.546,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-25",11,8.24,690.82,,0.002,0.001,353.247,0.0591,0.203,0.0953,5944.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-26",14,12.85,1242.78,,0.003,0.001,616.433,0.059,0.118,0.0306,10374.846,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-27",11,9.43,873.43,,0.002,0.001,437.952,0.0591,0.122,0.0463,7370.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-28",16,14.41,1390.11,,0.003,0.001,688.015,0.059,0.135,0.0353,11578.137,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-29",10,7.71,586.93,,0.002,0.001,303.647,0.059,0.15,0.0862,5109.614,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-02",14,12.75,1168,,0.003,0.001,582.591,0.0591,0.137,0.0461,9806.482,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-03",12,10.42,974.69,,0.002,0.001,483.286,0.0591,0.103,0.0433,8133.993,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-04",12,9.92,777.17,,0.002,0.001,399.059,0.0591,0.152,0.07,6715.394,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-10",9,6.33,383.33,,0.001,0.001,212.858,0.059,0.172,0.1327,3583.393,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-11",1,0.22,1.32,,0,0.001,2.398,0.059,0.002,0.107,40.326,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-16",5,4.78,314.3,,0.001,0.001,168.828,0.059,0.201,0.142,2840.904,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-18",13,11.21,953.35,,0.002,0.001,479.719,0.0592,0.203,0.0626,8074.638,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-19",8,7.15,659.52,,0.002,0.001,327.206,0.0591,0.094,0.0491,5506.134,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-22",19,17.39,1654.05,,0.004,0.001,816.254,0.0591,0.174,0.0394,13734.167,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-09",8,7.38,644.85,,0.002,0.001,323.609,0.059,0.131,0.0658,5447.015,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-10",10,8.65,784.39,,0.002,0.001,390.112,0.0592,0.119,0.0574,6565.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-11",8,6.92,618.76,,0.002,0.001,308.56,0.0591,0.103,0.0591,5192.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-12",9,7.4,647.55,,0.002,0.001,324.175,0.059,0.115,0.063,5453.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-13",9,7.42,635.94,,0.002,0.001,319.474,0.059,0.135,0.0709,5376.042,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-15",8,6.95,579.97,,0.001,0.001,292.137,0.059,0.098,0.0619,4915.899,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-27",3,2.32,62.87,,0,0.001,46.651,0.059,0.058,0.15,784.998,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-28",10,8.78,751.57,,0.002,0.001,377.379,0.0591,0.198,0.0861,6350.051,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-29",8,6.35,538.2,,0.001,0.001,271.22,0.059,0.125,0.082,4566.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-30",9,8.13,716.58,,0.002,0.001,358.92,0.059,0.15,0.0646,6040.849,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-07-31",9,7.53,631.18,,0.002,0.001,317.117,0.059,0.16,0.0832,5337.303,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-01",9,7.75,667.72,,0.002,0.001,335.561,0.0591,0.138,0.0651,5646.802,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-03",8,6.53,535.18,,0.001,0.001,272.314,0.0591,0.14,0.0863,4580.102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-10",9,7.62,641.21,,0.002,0.001,326.628,0.0591,0.145,0.0733,5497.041,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-12",8,7.25,626.53,,0.002,0.001,318.304,0.059,0.103,0.0541,5355.399,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-13",14,13.05,1252,,0.003,0.001,618.655,0.059,0.131,0.0331,10409.985,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-14",14,12.98,1222.48,,0.003,0.001,604.97,0.0591,0.146,0.0391,10183.336,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-15",16,14.32,1393.08,,0.003,0.0009,688.846,0.059,0.128,0.0291,11592.268,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-16",18,16.38,1603.64,,0.004,0.001,788.642,0.059,0.142,0.0304,13276.788,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-17",16,13.77,1277.77,,0.003,0.0009,635.565,0.0591,0.167,0.0519,10694.614,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-18",16,15.4,1523.4,,0.004,0.001,747.05,0.059,0.13,0.025,12568.015,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-19",24,23.1,2340.4,,0.006,0.001,1140.94,0.059,0.157,0.0217,19200.91,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-20",14,13.05,1236.73,,0.003,0.001,610.093,0.059,0.108,0.027,10267.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-21",15,13.95,1336.1,,0.003,0.001,656.095,0.059,0.113,0.0323,11042.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-22",9,7.75,711.36,,0.002,0.001,353.506,0.0591,0.105,0.0504,5950.163,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-23",9,8.43,764.78,,0.002,0.001,381.738,0.059,0.129,0.0511,6425.074,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-24",10,9.3,855.8,,0.002,0.001,425.505,0.0591,0.114,0.0412,7157.795,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-25",11,10.78,1007.82,,0.003,0.001,498.304,0.059,0.121,0.0371,8388.03,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-26",24,24,2361,,0.006,0.001,1149.2,0.059,0.15,0.0155,19342.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-27",16,14.07,1348.64,,0.003,0.001,663.465,0.059,0.116,0.038,11163.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-28",15,14.05,1390.3,,0.003,0.001,680.73,0.0591,0.116,0.0253,11456.815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-29",12,10.5,994.02,,0.002,0.001,492.98,0.0591,0.119,0.0454,8299.225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-30",14,11.61,1106.96,,0.003,0.001,546.962,0.0592,0.1,0.0439,9202.054,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-08-31",12,10.1,957.57,,0.002,0.001,475.838,0.0591,0.088,0.0359,8007.056,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-01",14,12.26,1145.37,,0.003,0.001,569.174,0.059,0.116,0.0395,9580.284,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-03",13,11.07,1080.15,,0.003,0.001,534.255,0.0592,0.111,0.0399,8990.579,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-04",20,19.98,1996.1,,0.005,0.001,978.76,0.059,0.159,0.022,16473.822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-05",24,24,2375,,0.006,0.001,1164,0.059,0.154,0.0157,19591.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-06",24,24,2361,,0.006,0.001,1156.3,0.059,0.15,0.0154,19460.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-07",24,24,2376,,0.006,0.001,1161.2,0.059,0.158,0.0162,19540.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-08",24,23.07,2317.05,,0.006,0.001,1131.908,0.059,0.153,0.0221,19048.626,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-09",12,10.65,983.5,,0.002,0.001,487.24,0.0591,0.105,0.0434,8203.63,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-17",12,10.73,935.61,,0.002,0.001,473.04,0.059,0.129,0.0455,7960.916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-27",15,13.45,1208.48,,0.003,0.001,608.948,0.059,0.194,0.0553,10245.595,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-28",16,14.93,1444.68,,0.004,0.001,714.16,0.059,0.123,0.0302,12018.385,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-29",15,14.27,1395.9,,0.003,0.001,684.409,0.0591,0.125,0.0266,11518.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-09-30",13,12.01,1149.11,,0.003,0.001,565.157,0.059,0.109,0.034,9509.243,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-01",13,12.03,1147.46,,0.003,0.001,564.376,0.059,0.114,0.0385,9498.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-02",15,14,1340.34,,0.003,0.001,659.701,0.059,0.113,0.0329,11102.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-05",10,8.33,719.27,,0.002,0.001,364.296,0.059,0.154,0.0814,6131.047,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-06",14,12.58,1216.47,,0.003,0.001,598.791,0.0591,0.117,0.0406,10076.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-07",8,6.77,583.35,,0.001,0.001,290.691,0.059,0.119,0.0716,4891.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-12",20,18.42,1716.48,,0.004,0.001,853.954,0.059,0.218,0.0427,14371.342,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-13",18,16.95,1629.4,,0.004,0.001,804.605,0.0591,0.136,0.0304,13537.935,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-14",20,18.99,1861.53,,0.005,0.001,907.491,0.059,0.156,0.028,15264.185,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-15",19,18.9,1917.8,,0.005,0.001,932.25,0.059,0.156,0.0225,15687.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-16",24,23.02,2294.1,,0.006,0.001,1116.36,0.059,0.155,0.0207,18785.276,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-17",12,10.7,1001.99,,0.003,0.001,495.718,0.059,0.112,0.047,8340.707,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-18",7,6.43,586.22,,0.001,0.001,293.715,0.059,0.107,0.0633,4943.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-19",7,6.5,585.19,,0.001,0.001,294.182,0.059,0.104,0.059,4951.943,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-20",12,10.9,996.1,,0.003,0.001,496.136,0.059,0.138,0.0556,8349.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-21",7,5.65,479.75,,0.001,0.001,243.56,0.0591,0.11,0.0823,4098.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-22",8,6.98,609.34,,0.002,0.001,305.146,0.0591,0.119,0.0754,5133.958,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-26",9,7.43,627.61,,0.002,0.001,315.018,0.0591,0.205,0.1066,5302.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-27",8,7.01,630.6,,0.002,0.001,312.283,0.059,0.145,0.0818,5256.116,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-28",8,6.51,589.37,,0.001,0.001,291.134,0.0591,0.119,0.0805,4899.646,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-02",9,7.23,631.07,,0.002,0.001,315.999,0.0592,0.125,0.0749,5316.711,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-03",10,8.65,804.2,,0.002,0.001,398.84,0.0591,0.119,0.0611,6711.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-04",10,8.95,846.82,,0.002,0.001,416.731,0.059,0.112,0.0454,7011.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-05",9,8.4,787.4,,0.002,0.001,392.58,0.0591,0.109,0.0484,6606.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-09",9,7.82,701.78,,0.002,0.001,347.628,0.0591,0.161,0.0838,5848.902,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-10",8,7.27,668.2,,0.002,0.001,330.819,0.0591,0.11,0.0529,5566.386,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-11",8,7.1,644.27,,0.002,0.001,318.598,0.0591,0.097,0.0499,5361.855,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-12",8,6.89,629.48,,0.002,0.001,311.25,0.0593,0.108,0.0673,5235.597,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-16",8,5.4,329.08,,0.001,0.001,179.087,0.0593,0.184,0.1351,3014.772,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-02",7,5.75,441.24,,0.001,0.001,229.045,0.059,0.158,0.115,3854.916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-03",9,7.45,708.85,,0.002,0.001,352.83,0.059,0.105,0.0633,5939.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-04",10,8.82,861.26,,0.002,0.001,423.358,0.059,0.119,0.0506,7124.946,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-07",9,8.05,742.73,,0.002,0.001,371.225,0.0592,0.149,0.0736,6246.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-08",9,7.65,702.56,,0.002,0.001,351.532,0.059,0.141,0.0672,5915.206,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-09",10,8.1,740.63,,0.002,0.001,368.966,0.0592,0.137,0.0683,6208.679,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-12",9,8.03,722.74,,0.002,0.001,362.22,0.059,0.111,0.0549,6094.909,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-13",12,10.93,1052.67,,0.003,0.001,518.997,0.059,0.13,0.0468,8734.851,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-14",9,8.45,781.4,,0.002,0.001,389.165,0.059,0.124,0.0499,6550.225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-15",9,8.63,823.97,,0.002,0.001,407.042,0.059,0.117,0.0443,6847.647,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-16",4,2.77,100.98,,0,0.001,65.969,0.0593,0.095,0.1615,1110.131,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-17",9,7.83,728.47,,0.002,0.001,361.514,0.0591,0.11,0.0606,6084.698,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-18",9,8.1,779.4,,0.002,0.001,386.39,0.059,0.106,0.0464,6503.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-21",8,6.96,619.7,,0.002,0.001,311.448,0.0593,0.112,0.0671,5240.811,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-28",9,8.1,733.9,,0.002,0.001,366.49,0.059,0.131,0.0583,6165.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Calpine Gilroy Cogen, LP",10034,"S-100",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-24",1,0.08,0,,0,0.001,0.456,0.06,0,0.131,7.608,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-18",7,6.2,92,,0,0.0009,65.47,0.0683,0.004,0.008,1102.72,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-19",3,2.2,84.05,,0,0.001,52.96,0.0597,0.018,0.0567,889.865,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-21",3,2.52,55.04,,0,0.001,39.326,0.0593,0.003,0.0107,661.698,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-10",1,0.02,0,,0,0.001,0.164,0.06,0,0.001,2.748,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-15",1,0.15,0,,0,0.001,0.72,0.06,0,0.045,12,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-15",4,2.46,46.82,,0,0.001,33.528,0.0593,0.003,0.009,564.086,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-16",9,7.78,181.21,,0.001,0.001,129.986,0.0593,0.008,0.022,2185.317,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-17",10,9.45,246.6,,0.001,0.001,171.575,0.0593,0.011,0.0116,2886.795,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-18",16,14.32,329.83,,0.001,0.001,239.104,0.0594,0.015,0.019,4021.386,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-07",10,8.75,248.4,,0.001,0.001,170.037,0.0592,0.011,0.0136,2861.403,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-24",4,2.55,13.68,,0,0.001,19.111,0.0595,0.002,0.018,322.32,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-28",1,0.05,0,,0,0.001,0.265,0.06,0,0.023,4.44,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-09",1,0.55,9.35,,0,0.001,6.985,0.06,0.005,0.078,117.15,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-12",4,1.62,22.16,,0,0.001,20.974,0.0593,0.003,0.0218,353.133,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-13",2,0.69,13.92,,0,0.001,10.047,0.0595,0.001,0.0265,169.353,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-15",2,0.87,20.25,,0,0.001,13.788,0.0595,0.004,0.067,231.597,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-11",11,10.25,313.8,,0.001,0.001,193.285,0.0594,0.016,0.0125,3253.365,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-12",15,14.22,497.71,,0.002,0.001,299.355,0.0592,0.017,0.0086,5036.85,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Fresno Cogeneration Partners, LP",10156,"GEN1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-06",13,12.25,540.13,,0.001,0.001,265.404,0.0592,2.146,1.0243,4466.112,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-09",8,6.76,283.95,,0.001,0.001,140.909,0.0594,0.086,0.3274,2369.823,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-10",2,1.26,16.14,,0,0.001,13.71,0.06,0.078,1.3835,229.998,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-21",7,5.46,166.11,,0,0.001,91.4,0.059,1.617,2.1,1539.92,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-03",7,5.5,170.03,,0,0.001,93.09,0.0593,0.624,1.0479,1566.066,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-04",7,5.52,182.34,,0,0.001,97.092,0.0593,0.078,0.4414,1632.338,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-05",8,6.5,214.55,,0.001,0.001,115.435,0.0593,0.086,0.4623,1942.43,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-06",10,8.23,249.2,,0.001,0.001,137.51,0.0595,0.066,0.4126,2312.841,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-08",7,5.31,155.7,,0,0.001,86.639,0.0594,0.093,0.5771,1456.501,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-04-30",2,1.35,10.15,,0,0.001,11.99,0.059,0.089,0.7445,201.87,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-05",6,4.87,151.64,,0,0.001,83.437,0.059,0.539,1.2367,1404.338,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-06",5,4.08,130.78,,0,0.001,70.82,0.0594,0.31,0.9734,1191.296,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-07",8,6.22,220.05,,0.001,0.001,114.318,0.0591,0.035,0.5096,1925.279,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-08",7,5.23,197.65,,0.001,0.001,100.054,0.0591,0.065,0.5669,1685.979,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-26",9,7.57,292.6,,0.001,0.001,150.319,0.0596,0.129,0.3769,2527.712,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-27",7,5.52,201.22,,0.001,0.001,104.435,0.0593,0.076,0.4814,1756.646,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-02",7,5.77,200.7,,0.001,0.001,104.845,0.0591,0.083,0.3151,1764.907,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-03",7,5.23,177.65,,0,0.001,94.167,0.0596,0.063,0.5074,1582.962,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-04",8,6.23,199.35,,0.001,0.001,106.969,0.0593,0.07,0.4719,1800.746,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-09",7,5.9,227.25,,0.001,0.001,116.408,0.0591,0.086,0.3181,1959.851,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-10",7,5.32,193.22,,0.001,0.001,100.192,0.0594,0.059,0.5007,1686.336,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-11",7,5.36,186.52,,0,0.001,97.598,0.0593,0.061,0.4323,1641.016,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-26",7,5.97,187.19,,0.001,0.001,101.506,0.0593,0.085,0.3374,1707.465,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-27",7,5.73,168.45,,0,0.001,93.43,0.0591,0.07,0.3737,1574.318,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-06",5,3.38,106.4,,0,0.001,58.772,0.0592,0.11,0.7566,988.91,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-10",7,5.87,191.61,,0.001,0.001,102.42,0.0591,0.08,0.388,1724.118,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-11",10,8.47,288.46,,0.001,0.001,153.295,0.0592,0.061,0.3221,2579.981,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-12",7,5.29,177.04,,0,0.001,94.375,0.0593,0.055,0.3716,1588.067,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-13",7,5.27,171.53,,0,0.001,91.557,0.0591,0.067,0.527,1539.87,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-14",11,9.37,371.25,,0.001,0.001,187.498,0.0593,0.552,0.5365,3155.306,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-15",10,8.61,339.49,,0.001,0.001,171.211,0.0593,0.091,0.3868,2880.265,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-18",5,3.46,77.65,,0,0.001,47.751,0.0594,0.068,0.5898,801.932,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-20",5,3.46,78.11,,0,0.001,47.861,0.059,0.072,0.7034,806.769,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-24",3,2.88,63.88,,0,0.001,39.648,0.059,0.093,0.364,668.32,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-27",7,5.46,152.98,,0,0.001,85.863,0.0591,0.076,0.5184,1445.963,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-29",8,7.12,225.5,,0.001,0.001,121.668,0.0598,0.086,0.2079,2044.082,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-30",9,7.18,267.78,,0.001,0.001,137.552,0.0592,0.068,0.436,2312.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-07-31",10,8.21,300.78,,0.001,0.001,155.918,0.0593,0.077,0.4081,2624.184,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-01",7,5.21,178.91,,0,0.001,94.449,0.0596,0.061,0.4987,1587.936,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-02",7,5.03,145.34,,0,0.001,81.043,0.0594,0.127,0.698,1362.318,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-03",10,8.21,233.52,,0.001,0.001,128.093,0.059,0.067,0.4303,2158.148,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-04",4,3.33,88.99,,0,0.001,51.209,0.059,0.049,0.5353,862.657,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-05",3,2.13,58.65,,0,0.001,32.584,0.06,0.012,0.4307,546.881,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-06",4,3.33,86.33,,0,0.001,49.912,0.0593,0.063,0.588,840.073,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-07",7,5.21,142.65,,0,0.001,80.948,0.0594,0.066,0.591,1360.783,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-08",3,2.13,58.65,,0,0.001,32.81,0.0593,0.014,0.5147,551.727,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-09",6,4.22,101.36,,0,0.001,59.904,0.0593,0.079,0.6955,1008.748,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-12",7,5.46,177.85,,0,0.001,95.657,0.0593,0.077,0.5633,1609.47,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-13",10,9.13,302.52,,0.001,0.001,159.119,0.0593,0.067,0.202,2679.441,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-14",14,13.13,444.52,,0.001,0.001,232.532,0.0594,0.075,0.1495,3912.266,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-15",14,13.06,463.4,,0.001,0.001,239.058,0.0593,0.07,0.1486,4023.412,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-16",13,11.86,342.63,,0.001,0.001,185.129,0.0592,0.11,0.2421,3118.97,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-17",15,14.06,517.33,,0.001,0.001,262.644,0.0595,0.071,0.1413,4417.83,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-18",14,13.05,433.08,,0.001,0.001,226.382,0.0596,0.071,0.1489,3805.045,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-19",12,11.06,337.59,,0.001,0.001,181.394,0.0593,0.066,0.1431,3051.537,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-20",13,12.05,458.29,,0.001,0.001,231.11,0.0592,0.067,0.1455,3889.819,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-21",12,11.05,416.05,,0.001,0.001,210.035,0.0593,0.065,0.1918,3536.62,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-22",8,7.31,208.86,,0.001,0.001,114.01,0.0591,0.066,0.1141,1918.646,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-23",2,1.74,16.58,,0,0.001,17.42,0.059,0.04,0.2505,293.284,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-24",14,12.15,438.93,,0.001,0.0009,226.659,0.0594,0.05,0.3082,3812.159,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-25",12,11.05,328.4,,0.001,0.001,177.499,0.0591,0.064,0.1535,2990.67,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-26",10,9.04,262.28,,0.001,0.001,144.852,0.0593,0.068,0.1975,2436.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-27",2,1.46,37.27,,0,0.001,22.276,0.059,0.046,0.2515,375.469,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-28",10,8.18,287.65,,0.001,0.001,150.649,0.0591,0.039,0.4329,2537.157,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-03",9,7.4,192.79,,0.001,0.001,111.345,0.0597,0.204,0.5174,1873.08,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-04",10,9.06,340.53,,0.001,0.001,175.95,0.0592,0.066,0.1785,2959.006,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-05",14,13.05,515.29,,0.001,0.001,259.922,0.059,0.073,0.1416,4373.968,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-06",12,11.06,398.33,,0.001,0.001,206.458,0.0592,0.07,0.1703,3473.954,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-07",11,10.06,277.27,,0.001,0.001,155.546,0.0593,0.066,0.1865,2616.376,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-08",8,6.23,163.52,,0,0.001,93.036,0.0593,0.063,0.5011,1566.604,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-09",9,7.23,192.52,,0.001,0.001,107.923,0.0594,0.065,0.4459,1815.009,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-15",7,5.48,136.87,,0,0.001,79.324,0.0591,0.075,0.4937,1336.835,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-16",7,6.05,181.36,,0,0.001,98.045,0.0593,0.063,0.2749,1652.114,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-17",6,5.05,130.5,,0,0.001,75.099,0.0595,0.058,0.311,1262.816,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-18",6,5.38,190.98,,0.001,0.001,99.85,0.059,0.07,0.1447,1681.08,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-21",4,1.93,17.15,,0,0.001,18.364,0.0595,0.144,1.2618,308.603,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-24",7,5.47,139.83,,0,0.001,79.497,0.0594,0.089,0.6389,1338.362,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-28",10,8.47,235.83,,0.001,0.001,130.262,0.0592,0.204,0.6005,2193.353,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-29",10,9.05,268.43,,0.001,0.001,145.585,0.0593,0.026,0.1492,2448.255,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-09-30",13,12.06,336.4,,0.001,0.001,186.532,0.0595,0.074,0.1598,3136.995,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-01",12,10.92,309.46,,0.001,0.001,169.736,0.0592,0.062,0.1242,2859.847,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-02",13,12.06,340.47,,0.001,0.001,186.847,0.0595,0.075,0.1419,3141.163,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-03",9,8.05,233.5,,0.001,0.001,126.296,0.0593,0.073,0.2262,2124.705,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-05",16,14.47,471.83,,0.001,0.001,248.032,0.0592,0.096,0.2193,4172.573,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-06",14,13.05,377.24,,0.001,0.001,203.235,0.0594,0.071,0.1429,3420.629,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-12",7,5.45,179.81,,0,0.001,95.892,0.0596,0.075,0.5043,1611.653,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-13",7,6.05,185.5,,0.001,0.001,99.689,0.0591,0.062,0.2389,1677.576,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-14",8,7.06,244.54,,0.001,0.001,129.387,0.0593,0.065,0.2229,2176.892,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-15",10,9.06,274.54,,0.001,0.001,148.901,0.0594,0.067,0.2035,2503.245,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-16",9,8.06,228.34,,0.001,0.001,126.247,0.0594,0.062,0.2206,2121.991,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-17",7,6.05,165.5,,0,0.001,93.992,0.0596,0.063,0.2386,1578.939,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-20",7,5.47,146.83,,0,0.001,84.044,0.0591,0.078,0.4887,1413.644,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Carson Cogeneration Company",10169,"D1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-03",4,2.62,56.26,,0,0.0008,41.386,0.0598,0.007,0.0325,694.908,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-16",1,0.15,2.55,,0,0.001,2.115,0.059,0.002,0.094,35.625,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-26",2,1.12,33.32,,0,0.001,21.784,0.0595,0.006,0.037,366.408,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-12",2,1.32,27.72,,0,0.001,20.649,0.0595,0.003,0.0155,347.184,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-14",3,2.33,45.27,,0,0.001,34.917,0.0593,0.005,0.0173,587.335,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-16",8,6.07,128.72,,0,0.001,94.824,0.0594,0.011,0.0303,1595.385,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-25",2,0.85,30.25,,0,0.001,19.184,0.059,0.002,0.043,323.416,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-27",2,0.75,23.1,,0,0.001,15.095,0.06,0.003,0.0215,253.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-28",2,0.9,21.2,,0,0.001,15.07,0.059,0.003,0.0245,253.62,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-29",3,2.08,43.2,,0,0.001,32.188,0.059,0.006,0.021,541.728,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-13",2,1.03,22.36,,0,0.001,16.442,0.06,0.003,0.095,275.836,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-15",2,0.97,25.76,,0,0.001,17.525,0.0595,0.003,0.0205,294.744,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-19",9,7.87,160.86,,0.001,0.0009,122.338,0.0598,0.026,0.0281,2055.442,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-20",7,5.05,174.19,,0.001,0.001,110.257,0.0591,0.013,0.0263,1855.236,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-21",2,1.07,41.63,,0,0.001,25.362,0.059,0.004,0.0245,427.194,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-26",6,3.72,108.76,,0,0.001,71.476,0.0592,0.01,0.0178,1202.627,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-27",8,7.85,293.25,,0.001,0.001,180.605,0.059,0.019,0.0129,3040.575,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-29",2,1.07,25.84,,0,0.001,18.377,0.0595,0.004,0.085,308.604,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-03",8,7,152.6,,0.001,0.001,110.574,0.0595,0.013,0.0143,1859.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-04",5,4.27,92.13,,0,0.001,66.561,0.0592,0.009,0.0156,1119.727,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-09",4,2.62,103.86,,0,0.001,62.504,0.0598,0.007,0.0163,1051.516,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-10",7,5.05,137.34,,0,0.0009,92.547,0.0593,0.011,0.0234,1557.308,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-11",5,4.05,88.05,,0,0.001,64.17,0.0592,0.008,0.035,1079.885,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-15",5,3.05,65.47,,0,0.001,47.958,0.0592,0.007,0.0312,806.417,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-26",3,1.3,31.09,,0,0.001,21.942,0.0593,0.004,0.027,369.388,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-10",1,0.98,19.6,,0,0.001,14.994,0.059,0.003,0.024,252.546,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-11",4,2.87,116.02,,0,0.001,69.776,0.059,0.01,0.0168,1174.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-12",3,1.5,60.34,,0,0.001,36.054,0.0593,0.006,0.026,607.46,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-18",2,0.99,20.57,,0,0.001,15.356,0.059,0.003,0.0365,258.83,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-21",1,0.98,20.58,,0,0.001,15.19,0.059,0.004,0.028,256.368,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-26",2,1.07,21.92,,0,0.001,16.368,0.059,0.004,0.027,275.309,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-27",3,2,43.62,,0,0.001,31.632,0.0593,0.005,0.0173,532.278,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-28",3,1.08,23.04,,0,0.001,16.827,0.06,0.003,0.0507,282.545,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-29",3,2.17,46.93,,0,0.001,34.235,0.0593,0.005,0.0163,576.388,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-30",5,4.27,121.13,,0,0.001,80.896,0.0594,0.011,0.0168,1360.668,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-07-31",2,1.96,43.12,,0,0.001,31.36,0.059,0.005,0.019,527.828,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-01",2,0.97,20.96,,0,0.0005,15.332,0.0595,0.004,0.0215,257.689,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-03",3,1.24,26.9,,0,0.001,19.668,0.0593,0.006,0.05,330.534,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-10",2,1.25,26.69,,0,0.001,19.453,0.06,0.004,0.022,326.674,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-12",2,1.14,38.34,,0,0.001,24.062,0.0595,0.004,0.019,404.452,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-13",6,5.12,169.68,,0.001,0.001,106.316,0.0593,0.013,0.0147,1789.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-14",8,7.28,178.32,,0.001,0.001,123.86,0.0596,0.016,0.0151,2080.96,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-15",7,5.76,245.94,,0.001,0.001,144.74,0.0591,0.016,0.0163,2436.853,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-16",7,5.75,170.5,,0.001,0.001,110.825,0.0594,0.013,0.0186,1863.125,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-17",11,10.6,412.2,,0.001,0.001,249.22,0.0593,0.025,0.0122,4192.42,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-18",14,12.87,526.78,,0.002,0.001,313.997,0.0592,0.034,0.0133,5284.375,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-19",10,9.62,265.56,,0.001,0.001,177.784,0.0594,0.021,0.014,2990.82,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-20",6,4.09,88.42,,0,0.001,64.248,0.0597,0.01,0.0433,1079.88,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-24",4,2.8,60.53,,0,0.001,44.164,0.059,0.008,0.0218,743.944,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-27",4,2.07,43.44,,0,0.001,31.878,0.0593,0.006,0.0275,537.219,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-28",3,1.05,21.4,,0,0.0007,16.072,0.059,0.005,0.0523,271.254,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-04",3,2.25,49.5,,0,0.001,35.9,0.0593,0.006,0.0287,604.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-05",8,6.1,133.56,,0,0.001,96.78,0.0594,0.013,0.0305,1627.688,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-06",8,7.07,206.4,,0.001,0.001,135.164,0.0593,0.017,0.0323,2273.334,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-07",5,4.17,117.95,,0,0.001,78.072,0.059,0.011,0.025,1314.48,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-09",3,1.29,27.98,,0,0.001,20.23,0.0597,0.005,0.043,339.753,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-10",4,2.05,43.55,,0,0.001,32.018,0.0593,0.006,0.0535,539.51,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-15",3,1.09,22.21,,0,0.001,16.645,0.059,0.005,0.0673,280.006,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-16",11,8.92,250.39,,0.001,0.001,166.797,0.0594,0.021,0.0188,2807.842,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-17",3,1.57,33.12,,0,0.001,24.547,0.059,0.005,0.0353,412.639,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-19",4,2.72,64.98,,0,0.001,45.773,0.0593,0.009,0.0243,771.338,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-21",1,0.03,0,,0,0.001,0.177,0.059,0,0.022,3.003,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-28",6,3.78,120.28,,0,0.001,76.83,0.0592,0.013,0.0507,1291.73,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-29",3,2,61.6,,0,0.0007,39.714,0.059,0.006,0.018,668.882,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-09-30",15,13.13,508.99,,0.002,0.001,307.874,0.0594,0.033,0.0179,5178.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-01",5,4.03,94.06,,0,0.001,65.965,0.0594,0.008,0.0146,1109.963,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-02",2,1.36,36.25,,0,0.001,24.47,0.0595,0.003,0.0165,411.741,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-03",2,1.18,45.66,,0,0.001,27.824,0.0595,0.005,0.0225,467.858,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-04",2,0.88,28.88,,0,0.001,18.263,0.0595,0.004,0.067,307.528,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-05",4,3.19,137.97,,0,0.001,81.268,0.0593,0.01,0.0155,1367.779,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-06",2,1.13,40.18,,0,0.001,25.094,0.0595,0.005,0.021,422.403,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-07",2,1.08,23.25,,0,0.001,17.129,0.0595,0.003,0.0235,288.175,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-12",3,1.28,26.06,,0,0.001,19.64,0.0593,0.004,0.0333,331.104,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-13",3,1.7,36.18,,0,0.001,26.676,0.0593,0.004,0.0297,448.306,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-14",5,3.81,143.33,,0,0.001,88.281,0.0594,0.009,0.0394,1485.633,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-15",4,3.08,111.78,,0,0.001,68.202,0.059,0.008,0.015,1148.938,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-16",2,1.28,35.13,,0,0.001,23.109,0.0595,0.005,0.0245,388.643,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-18",3,1.55,33.28,,0,0.001,23.88,0.0597,0.005,0.0333,401.038,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-19",3,1.54,50.47,,0,0.001,31.676,0.0593,0.006,0.0303,532.821,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-20",2,1.15,24.52,,0,0.001,17.513,0.059,0.003,0.024,295.388,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-21",2,1.05,22.58,,0,0.001,16.225,0.0595,0.003,0.0235,272.933,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-23",2,1.08,23.58,,0,0.001,16.914,0.0595,0.006,0.0655,284.124,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-29",1,0.07,0,,0,0.001,0.364,0.06,0,0.102,6.097,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-02",3,1.37,31.79,,0,0.0007,22.11,0.0593,0.006,0.0353,371.767,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-03",2,1.05,39.38,,0,0.001,23.889,0.059,0.003,0.013,402.073,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-04",5,4.45,166.75,,0.001,0.001,101.531,0.059,0.011,0.0142,1709.631,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-05",6,4.52,123.06,,0,0.0008,81.636,0.0593,0.009,0.0142,1374.394,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-06",4,2.88,65.45,,0,0.001,45.741,0.0593,0.007,0.0233,769.481,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-08",5,3.25,101.89,,0,0.0008,64.999,0.0594,0.008,0.023,1092.862,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-09",5,3.3,90.34,,0,0.001,60.104,0.0592,0.011,0.0234,1011.792,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-10",4,2.83,99.68,,0,0.001,61.798,0.0595,0.008,0.018,1039.969,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-11",4,2.88,59.98,,0,0.001,43.976,0.0593,0.007,0.0185,739.479,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-12",3,1.35,43.97,,0,0.001,27.821,0.0597,0.004,0.033,467.454,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-14",2,1.09,22.89,,0,0.001,17.023,0.06,0.004,0.0355,285.98,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-15",3,2.55,104.1,,0,0.001,62.645,0.0593,0.008,0.016,1054.365,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-16",2,1.23,34.06,,0,0.001,22.957,0.0595,0.003,0.0315,386.264,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-17",2,1.05,22.05,,0,0.001,16.303,0.059,0.003,0.0285,274.813,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-20",2,0.98,21.85,,0,0.001,16.044,0.06,0.003,0.0405,269.312,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-21",3,1.1,22.3,,0,0.001,16.984,0.059,0.004,0.0403,285.784,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-22",4,2.5,55,,0,0.001,40.275,0.0593,0.006,0.024,677.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-24",5,2.91,104.01,,0,0.001,64.778,0.0594,0.01,0.0522,1090.134,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-29",3,1.62,39.85,,0,0.001,27.602,0.059,0.004,0.0203,465.397,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-11-30",3,2.43,96.54,,0,0.001,58.573,0.0593,0.008,0.0187,984.757,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-01",6,3.89,157.05,,0,0.001,95.196,0.0592,0.012,0.0222,1601.504,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-02",4,2.38,85.54,,0,0.001,53.63,0.0595,0.011,0.0335,901.984,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-03",5,3.87,141.62,,0,0.001,87.036,0.0592,0.01,0.0164,1465.024,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-04",7,5.65,236.57,,0.001,0.001,141.681,0.0596,0.021,0.0196,2381.621,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-05",2,1.32,21.48,,0,0.001,18.018,0.059,0.004,0.031,303.873,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-06",2,1.07,23.11,,0,0.001,17.044,0.059,0.004,0.0405,287.33,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-07",7,5.69,213.06,,0.001,0.001,131.458,0.0593,0.018,0.0193,2210.916,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-08",2,1.08,23.26,,0,0.001,17.113,0.059,0.005,0.026,287.873,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-09",5,3.8,134.9,,0,0.001,84.33,0.0592,0.011,0.0238,1419.17,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-10",7,5.58,207.21,,0.001,0.001,128.339,0.0593,0.018,0.02,2158.444,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-11",8,6.45,260.22,,0.001,0.001,157.769,0.059,0.026,0.0303,2656.963,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-12",7,6.12,271.56,,0.001,0.001,160.796,0.0591,0.017,0.0136,2707,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-13",12,11.07,314.47,,0.001,0.001,209.813,0.0593,0.024,0.0228,3531.297,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-14",9,6.41,243.98,,0.001,0.001,150.681,0.0592,0.02,0.0349,2535.895,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-15",2,1.05,38.65,,0,0.001,24.06,0.059,0.008,0.038,404.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-16",2,1.03,21.13,,0,0.001,15.843,0.059,0.004,0.0235,266.394,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-18",3,2.3,89.66,,0,0.001,54.878,0.0593,0.008,0.0217,923.221,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-19",2,1.22,31.84,,0,0.001,22.064,0.059,0.005,0.052,372.016,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-23",2,1.05,29.4,,0,0.001,19.635,0.059,0.003,0.0245,330.708,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-27",2,1.07,23.67,,0,0.001,17.249,0.0595,0.003,0.0265,289.668,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-28",2,1.16,46.4,,0,0.001,28.241,0.059,0.004,0.0165,475.046,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"2",,"2020-12-31",2,1.03,27.51,,0,0.001,18.85,0.059,0.003,0.0215,317.82,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-04",1,0.02,0,,0,0.001,0.276,0.059,0,0,4.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-08",5,3.65,149.84,,0.001,0.001,105.822,0.0594,0.498,0.4318,1781.361,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-18",13,11.25,813.75,,0.002,0.001,433.669,0.059,0.153,0.0498,7296.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-19",7,5.74,390.32,,0.001,0.001,211.91,0.0591,0.084,0.0543,3565.492,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-20",14,10.25,768.93,,0.002,0.001,404.243,0.0591,0.57,0.1824,6803.301,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-26",10,8.2,686.54,,0.002,0.001,344.471,0.0593,0.118,0.0515,5794.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-27",9,8.15,776.35,,0.002,0.001,375.584,0.059,0.119,0.0473,6320.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-28",7,5.53,409.5,,0.001,0.001,212.312,0.0591,0.077,0.0504,3571.515,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-03",8,6.62,521.4,,0.001,0.001,266.502,0.059,0.098,0.0524,4485.618,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-04",7,5.55,398.65,,0.001,0.001,210.275,0.059,0.081,0.0537,3537.265,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-10",7,5.75,443.04,,0.001,0.001,229.826,0.0591,0.086,0.0491,3866.708,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-11",8,6.5,563.32,,0.001,0.001,280.328,0.0594,0.09,0.0453,4716.354,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-17",14,12.76,1193.41,,0.003,0.001,579.071,0.0591,0.177,0.0411,9743.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-10",7,5.36,387.34,,0.001,0.001,204.106,0.059,0.077,0.0593,3433.993,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-12",9,7.81,709.02,,0.002,0.001,351.018,0.059,0.119,0.0568,5906.067,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-13",9,7.14,542.36,,0.001,0.001,280.174,0.0593,0.093,0.0537,4712.994,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-20",7,5.43,359.66,,0.001,0.001,196.479,0.0593,0.081,0.0589,3305.671,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-27",7,5.7,395.41,,0.001,0.001,213.435,0.0591,0.089,0.056,3591.618,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-29",9,7.18,579.74,,0.001,0.001,295.635,0.0591,0.1,0.0519,4975.703,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-30",8,6.88,592.7,,0.001,0.001,296.517,0.0593,0.095,0.0459,4986.705,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-07-31",8,6.78,504.55,,0.001,0.001,261.171,0.059,0.095,0.0501,4394.621,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-01",7,5.25,364.92,,0.001,0.001,195.542,0.0593,0.076,0.0524,3291.149,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-03",7,5.88,416.6,,0.001,0.001,220.879,0.059,0.083,0.0473,3717.654,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-12",7,6.5,505.4,,0.001,0.001,259.047,0.059,0.097,0.0523,4357.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-13",12,11.02,1086.5,,0.003,0.001,518.034,0.0591,0.158,0.0447,8720.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-14",14,13.35,1351.4,,0.003,0.001,633.24,0.0591,0.176,0.0369,10656.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-15",15,14.5,1542,,0.004,0.001,718.45,0.0591,0.196,0.0373,12091.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-16",19,16.56,1709.35,,0.004,0.001,800.059,0.0591,0.215,0.0367,13464.476,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-17",16,15.05,1622.33,,0.004,0.001,759.7,0.059,0.205,0.0376,12784.152,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-18",16,14.75,1580.52,,0.004,0.001,738.845,0.0591,0.199,0.0381,12431.816,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-19",14,12.25,1197.76,,0.003,0.001,569.733,0.059,0.159,0.0456,9586.404,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-20",12,10.5,858.32,,0.002,0.001,426.006,0.0591,0.127,0.047,7166.504,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-21",13,11.75,969.64,,0.002,0.001,478.538,0.059,0.14,0.0371,8052.485,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-22",7,5.76,472.33,,0.001,0.001,237.527,0.0591,0.08,0.0439,3997.471,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-23",7,5.55,466.47,,0.001,0.001,231.809,0.059,0.08,0.0477,3902.874,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-24",9,7.54,647.36,,0.002,0.0009,318.82,0.0591,0.097,0.0392,5365.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-25",9,7.53,624.12,,0.002,0.001,310.717,0.0591,0.098,0.0441,5230.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-26",22,21.25,1874.75,,0.005,0.001,912.85,0.059,0.247,0.036,15354.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-27",15,12.37,1046.25,,0.003,0.001,515.366,0.0593,0.148,0.0376,8667.929,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-28",9,8.65,703.15,,0.002,0.001,349.965,0.0592,0.115,0.047,5889.565,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-29",9,7.75,607.76,,0.002,0.001,307.755,0.059,0.1,0.0454,5176.709,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-03",9,7.73,575.29,,0.002,0.001,297.252,0.0591,0.102,0.0461,5001.611,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-04",14,13.73,1291.03,,0.003,0.001,618.386,0.059,0.172,0.0374,10407.245,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-05",24,24,2347,,0.006,0.001,1100.4,0.059,0.265,0.0286,18514.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-06",24,22.67,2190.32,,0.005,0.001,1029.36,0.059,0.257,0.031,17318.505,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-07",24,24,2459,,0.006,0.001,1138,0.059,0.276,0.0288,19147.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-08",24,23.03,2213,,0.005,0.001,1047.318,0.059,0.255,0.0289,17620.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-09",13,11.7,945.37,,0.002,0.001,473.891,0.0592,0.137,0.037,7971.787,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-15",14,13.25,1126.16,,0.003,0.001,564.018,0.059,0.187,0.0477,9489.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-27",9,8,587.79,,0.002,0.001,301.568,0.0591,0.111,0.0507,5074.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-28",8,6.75,566.45,,0.001,0.001,283.242,0.059,0.096,0.0471,4769.075,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-29",9,7.68,668.8,,0.002,0.001,332.447,0.059,0.108,0.0441,5593.962,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-09-30",11,10.01,877.83,,0.002,0.001,428.393,0.059,0.131,0.0428,7209.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-01",12,10.73,897.43,,0.002,0.001,440.138,0.0592,0.138,0.0423,7405.904,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-02",10,8.75,733.55,,0.002,0.001,361.88,0.0592,0.113,0.0445,6088.245,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-06",7,6.01,448.82,,0.001,0.001,238.897,0.059,0.089,0.0491,4019.775,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-12",12,11.02,843.78,,0.002,0.001,429.754,0.059,0.142,0.0484,7236.374,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-13",13,11.92,981.7,,0.002,0.001,492.998,0.0591,0.148,0.0388,8294.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-14",14,12.5,1158.32,,0.003,0.001,565.38,0.059,0.158,0.0387,9512.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-15",18,17.23,1582.3,,0.004,0.001,758.109,0.0591,0.198,0.0354,12754.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-16",22,20.26,1783.28,,0.004,0.001,861.803,0.059,0.228,0.0333,14500.163,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-17",12,10.51,882.89,,0.002,0.001,426.995,0.0592,0.131,0.0413,7183.749,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-18",7,5.75,431.99,,0.001,0.001,217.152,0.0593,0.079,0.0543,3653.792,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-19",10,8.78,781.9,,0.002,0.001,376.484,0.059,0.111,0.0383,6334.534,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-20",8,6.56,493.92,,0.001,0.001,250.53,0.0591,0.084,0.0444,4214.836,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-21",6,5.75,445.75,,0.001,0.001,224.95,0.059,0.08,0.0517,3786.525,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-02",8,6.1,471.07,,0.001,0.001,240.914,0.0593,0.094,0.0541,4055.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-03",10,8.08,734,,0.002,0.001,359.252,0.0591,0.121,0.0489,6045.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-04",7,6.5,570.16,,0.001,0.001,283.237,0.0591,0.097,0.0497,4765.392,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-05",9,8.51,662.84,,0.002,0.001,332.602,0.059,0.11,0.0449,5598.281,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-08",6,5.19,347,,0.001,0.001,192.319,0.0592,0.088,0.0685,3234.81,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-13",9,8.67,762.43,,0.002,0.001,388.61,0.0591,0.128,0.0469,6538.319,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","King City Power Plant",10294,"GTG",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-02",4,2.27,44.28,,0,0.001,33.309,0.0593,0.069,0.7353,560.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-06",2,1.29,25.8,,0,0.001,19.035,0.059,0.068,0.4125,320.566,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-10",2,1.3,30.9,,0,0.001,21.334,0.059,0.058,0.527,359.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-13",10,8.55,316.55,,0.001,0.001,188.59,0.0592,0.087,0.1829,3174.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-14",4,2.3,48.15,,0,0.001,34.4,0.0593,0.089,0.626,578.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-15",24,24,656,,0.002,0.001,424.9,0.0593,0.062,0.0181,7149.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-16",12,10.1,444.04,,0.001,0.001,251.057,0.0592,0.113,0.1708,4227.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-17",17,16.47,350.4,,0.001,0.001,249.121,0.0594,0.096,0.0845,4192.629,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-18",24,24,504,,0.002,0.001,361,0.0593,0.039,0.013,6073.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-19",24,24,510,,0.002,0.001,361.2,0.0595,0.039,0.013,6073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-20",13,12.87,324.53,,0.001,0.001,214.906,0.0596,0.032,0.0198,3612.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-21",18,17.29,359.89,,0.001,0.001,257.073,0.0594,0.085,0.0535,4325.329,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-22",23,19.54,418.07,,0.001,0.001,294.553,0.0593,0.091,0.2198,4957.494,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-23",20,18.54,398.46,,0.001,0.001,282.854,0.0594,0.073,0.0977,4759.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-24",11,8.12,166.96,,0.001,0.001,121.358,0.0594,0.096,0.3552,2040.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-27",3,1.36,26.12,,0,0.001,19.724,0.0593,0.051,0.8427,332.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-28",9,6.26,126.58,,0,0.001,93.959,0.0593,0.109,0.5942,1580.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-29",5,4.3,98.7,,0,0.001,71.74,0.0592,0.056,0.173,1208.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-30",5,2.89,55.66,,0,0.001,42.722,0.0594,0.12,0.656,718.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-01-31",5,2.63,49.99,,0,0.001,37.683,0.059,0.09,0.5668,634.299,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-02",3,1.38,27.14,,0,0.001,20.076,0.0593,0.058,0.84,338.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-04",6,2.68,53.96,,0,0.001,39.644,0.0592,0.124,0.9382,667.768,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-05",2,1.48,30.1,,0,0.001,21.956,0.0595,0.073,0.5025,369.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-06",5,2.73,54.75,,0,0.001,40.253,0.0592,0.126,0.6702,678.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-07",3,1.48,27.08,,0,0.001,20.758,0.0593,0.077,0.9083,349.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-08",1,0.17,2.38,,0,0.001,2.074,0.06,0.028,1.632,34.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-09",24,23.27,489.7,,0.002,0.001,356.616,0.0593,0.082,0.053,6002.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-10",1,0.12,0.6,,0,0.001,0.996,0.059,0.007,0.812,16.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-11",4,2.5,47.93,,0,0.001,34.972,0.059,0.107,0.4398,589.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-12",4,2.76,54.31,,0,0.001,39.342,0.0593,0.098,0.3053,662.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-13",2,1.27,24.57,,0,0.001,17.645,0.059,0.048,0.3225,297.083,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-14",5,3.35,89.2,,0,0.001,58.736,0.0594,0.119,0.2794,987.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-21",1,0.28,3.08,,0,0.001,2.94,0.059,0.041,1.672,49.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-26",3,1.32,24.88,,0,0.001,18.576,0.059,0.045,0.87,313.144,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-28",1,0.15,2.25,,0,0.001,1.89,0.06,0.027,1.672,31.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-02-29",24,24,505,,0.002,0.001,357.7,0.0593,0.054,0.0178,6022.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-01",1,0.12,0.6,,0,0.001,0.948,0.059,0.007,0.814,16.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-03",6,4.69,96.88,,0,0.001,68.606,0.0595,0.058,0.2923,1153.065,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-12",8,6.25,138.03,,0,0.001,97.037,0.0595,0.046,0.1915,1631.289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-13",10,8.13,190.43,,0.001,0.001,130.489,0.0594,0.107,0.2034,2196.027,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-14",5,4.68,185.52,,0.001,0.001,109.43,0.0592,0.09,0.1212,1841.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-16",10,9.23,220.68,,0.001,0.001,151.559,0.0593,0.056,0.1578,2550.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-17",8,7.12,153.48,,0.001,0.001,107.736,0.0591,0.018,0.1129,1814.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-18",2,1.24,24.19,,0,0.001,17.612,0.059,0.047,0.288,296.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-22",3,1.6,31.4,,0,0.001,23.404,0.059,0.044,0.597,394.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-26",2,0.87,26.52,,0,0.001,17.049,0.059,0.067,0.4755,287.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-02",5,3.32,66.76,,0,0.001,48.932,0.0592,0.054,0.5454,824.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-03",2,1.25,23.75,,0,0.001,17.951,0.0595,0.049,0.4595,301.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-05",2,1.25,23.52,,0,0.001,17.871,0.0595,0.071,0.4095,300.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-07",5,3.61,73.6,,0,0.001,54.368,0.0598,0.053,0.3806,913.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-08",3,1.49,28.48,,0,0.001,21.352,0.059,0.047,0.6327,359.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-09",2,1.27,24.81,,0,0.001,18.687,0.06,0.068,0.4165,313.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-22",6,5.25,110.75,,0,0.001,80.211,0.0593,0.119,0.248,1349.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-23",11,9.37,200.73,,0.001,0.001,142.122,0.0593,0.05,0.19,2390.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-24",10,7.83,174.77,,0.001,0.001,123.612,0.0591,0.104,0.2569,2083.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-25",7,6.83,149.43,,0.001,0.001,104.782,0.0593,0.043,0.0551,1762.519,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-26",7,5.39,115.88,,0,0.001,82.808,0.0591,0.064,0.1629,1393.433,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-28",8,7.67,240.4,,0.001,0.001,150.383,0.0596,0.049,0.0621,2528.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-29",14,13.87,303.4,,0.001,0.001,211.215,0.0594,0.035,0.0211,3555.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-04-30",6,4.24,85.53,,0,0.001,61.984,0.0592,0.091,0.3597,1042.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-01",5,3.32,65.73,,0,0.001,48.397,0.059,0.094,0.298,815.769,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-02",6,4.29,117.15,,0,0.001,76.426,0.0592,0.051,0.392,1285.103,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-03",5,4.49,104.55,,0,0.001,71.654,0.0594,0.052,0.1186,1204.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-04",23,21.42,513.24,,0.002,0.001,349.602,0.0592,0.114,0.0976,5883.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-05",13,10.38,263,,0.001,0.001,176.475,0.0592,0.112,0.2358,2969.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-06",13,11.12,307.75,,0.001,0.001,199.744,0.0592,0.099,0.2601,3361.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-07",23,21.78,581.89,,0.002,0.001,380.819,0.0594,0.086,0.0837,6405.509,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-08",23,21.14,650.03,,0.002,0.001,403.762,0.0593,0.101,0.1164,6796.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-09",8,6.95,208.4,,0.001,0.001,131.365,0.0593,0.059,0.1854,2210.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-11",3,1.34,34.12,,0,0.001,22.932,0.0597,0.055,0.7703,385.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-13",3,1.18,20.72,,0,0.001,15.697,0.0597,0.044,0.7707,263.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-16",3,1.35,35.86,,0,0.001,23.719,0.06,0.044,0.782,398.447,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-19",3,1.34,28,,0,0.001,19.93,0.0593,0.046,0.756,336.144,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-21",4,2.79,93,,0,0.001,56.624,0.0595,0.05,0.2233,951.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-22",4,2.52,103.48,,0,0.001,59.648,0.0593,0.055,0.3453,1002.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-23",3,1.54,46.02,,0,0.001,28.946,0.0593,0.05,0.518,486.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-25",9,8.73,336.47,,0.001,0.001,194.771,0.0591,0.069,0.0514,3277.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-26",16,14.22,532.48,,0.002,0.001,309.388,0.0591,0.076,0.1888,5207.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-27",24,24,868,,0.003,0.001,498.1,0.0593,0.055,0.0132,8381.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-28",17,15.37,488.69,,0.001,0.001,290.226,0.0592,0.077,0.1489,4885.581,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-29",12,9.57,262.39,,0.001,0.001,163.896,0.0595,0.06,0.1304,2760.035,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-01",2,1.29,24.93,,0,0.001,18.186,0.06,0.043,0.3925,305.253,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-02",22,19.92,649.3,,0.002,0.001,392.526,0.0593,0.121,0.1453,6605.982,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-03",24,24,705,,0.002,0.001,433.7,0.0595,0.053,0.0145,7292.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-04",24,24,588,,0.002,0.001,378.2,0.0594,0.045,0.0141,6360.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-05",11,8.47,181.28,,0.001,0.001,122.008,0.0592,0.064,0.3151,2052.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-06",3,1.27,25.58,,0,0.001,17.852,0.0597,0.047,0.9653,299.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-07",17,16.17,354.89,,0.001,0.001,240.327,0.0594,0.069,0.108,4042.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-08",15,13.22,328.66,,0.001,0.001,214.704,0.0592,0.071,0.139,3613.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-09",6,5.74,226.03,,0.001,0.001,130.718,0.0595,0.073,0.0788,2198.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-10",10,8.67,319.85,,0.001,0.001,186.455,0.0592,0.102,0.1696,3138.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-11",12,9.85,255.1,,0.001,0.001,162.837,0.0593,0.121,0.2773,2740.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-14",7,5.41,118.74,,0,0.001,81.094,0.0594,0.096,0.3453,1363.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-15",9,7.83,171,,0.001,0.001,116.996,0.0596,0.058,0.1971,1966.808,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-16",8,6.99,149.13,,0.001,0.001,103.687,0.0595,0.111,0.1423,1743.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-17",7,5.79,123.71,,0,0.001,85.206,0.0594,0.057,0.2659,1433.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-18",6,5.12,131.4,,0,0.001,84.966,0.0592,0.057,0.1385,1430.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-19",12,11.05,377,,0.001,0.001,224.01,0.0592,0.059,0.1719,3768.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-20",17,13.77,342.16,,0.001,0.001,222.391,0.0593,0.121,0.2331,3743.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-21",14,12.27,382.91,,0.001,0.001,234.127,0.0592,0.086,0.1356,3941.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-22",14,13.85,458,,0.001,0.001,270.955,0.0594,0.07,0.0389,4559.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-23",18,15.36,397.21,,0.001,0.001,249.307,0.0594,0.115,0.1634,4193.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-24",10,7.65,242.06,,0.001,0.001,141.533,0.0592,0.139,0.3268,2381.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-25",12,8.96,313.79,,0.001,0.001,179.518,0.0592,0.095,0.37,3021.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-26",20,17.06,499.1,,0.002,0.001,298.004,0.0594,0.126,0.2041,5014.594,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-29",3,1.95,39.52,,0,0.001,27.93,0.0597,0.047,0.2553,469.487,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-06-30",17,15.19,559.59,,0.002,0.001,325.083,0.0593,0.083,0.0847,5469.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-01",14,10.89,340.96,,0.001,0.001,206.485,0.0592,0.104,0.359,3475.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-02",7,5.45,122.74,,0,0.001,82.986,0.0593,0.053,0.2549,1396.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-03",11,8.53,273.7,,0.001,0.001,165.067,0.0595,0.103,0.3235,2776.629,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-04",8,6.74,212.32,,0.001,0.001,128.578,0.0594,0.083,0.2693,2162.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-05",14,12.24,321.16,,0.001,0.001,207.728,0.0592,0.069,0.201,3494.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-07",17,14.9,339.08,,0.001,0.001,228.338,0.0592,0.117,0.1464,3843.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-08",17,14.29,352.93,,0.001,0.001,228.882,0.0592,0.109,0.2326,3853.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-09",24,22.35,699.51,,0.002,0.001,416.128,0.0591,0.164,0.1472,7004.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-10",19,16.82,429.07,,0.001,0.001,274.782,0.0594,0.124,0.1626,4620.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-11",23,22.88,991.32,,0.003,0.001,539.208,0.0592,0.108,0.0241,9071.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-12",13,12.97,326.83,,0.001,0.001,206.746,0.0595,0.069,0.0333,3477.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-13",10,7.86,199.36,,0.001,0.001,128.63,0.0595,0.061,0.2427,2162.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-14",8,7.55,179.2,,0.001,0.001,116.225,0.0593,0.049,0.0765,1955.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-15",16,14.24,364.28,,0.001,0.001,235.564,0.0593,0.075,0.1795,3963.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-16",24,22.5,639.75,,0.002,0.001,402.85,0.0593,0.099,0.109,6777.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-17",9,6.49,148.71,,0.001,0.001,101.699,0.0596,0.067,0.3381,1710.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-18",11,8.86,291.97,,0.001,0.001,175.742,0.0591,0.112,0.2724,2959.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-19",19,17.85,535.1,,0.002,0.001,330.354,0.0592,0.117,0.089,5561.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-21",13,9.71,240.63,,0.001,0.001,159.286,0.0596,0.101,0.4275,2679.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-22",12,9.68,286.63,,0.001,0.001,179.43,0.0593,0.107,0.2082,3017.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-23",10,9.31,233.2,,0.001,0.001,156.704,0.0592,0.061,0.0787,2639.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-24",22,19.62,614.97,,0.002,0.001,382.161,0.0593,0.114,0.1664,6430.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-25",14,12.79,423.53,,0.001,0.001,258.236,0.0594,0.076,0.1361,4345.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-26",18,15.3,432.41,,0.001,0.001,274.851,0.0593,0.115,0.2377,4624.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-27",13,11.1,338.82,,0.001,0.001,209.894,0.0594,0.121,0.1307,3530.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-28",22,19.04,606.6,,0.002,0.001,366.028,0.0593,0.125,0.21,6155.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-29",16,14.85,344.15,,0.001,0.001,231.025,0.0591,0.103,0.1091,3890.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-30",6,4.4,94.66,,0,0.001,65.037,0.0595,0.067,0.2807,1094.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-07-31",8,5.16,130.64,,0,0.001,85.166,0.0594,0.083,0.4526,1432.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-02",11,10.12,373.44,,0.001,0.001,219.168,0.0591,0.056,0.1602,3687.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-03",14,11.92,316.14,,0.001,0.001,203.56,0.0591,0.076,0.1944,3424.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-04",8,7.88,205.39,,0.001,0.001,133.988,0.0595,0.07,0.071,2253.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-07",10,8.63,225.22,,0.001,0.001,148.298,0.0594,0.061,0.2638,2494.171,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-08",12,11.47,272.4,,0.001,0.001,186.55,0.0594,0.055,0.0611,3139.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-09",17,15.7,473.68,,0.002,0.001,297.026,0.0592,0.076,0.0708,5001.169,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-10",17,16.03,497.83,,0.002,0.001,302.478,0.0592,0.072,0.0708,5091.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-11",22,20.74,606,,0.002,0.001,370.988,0.0593,0.079,0.0679,6241.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-12",24,21.62,565.83,,0.002,0.001,365.627,0.0594,0.109,0.1198,6149.019,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-13",24,23.42,823.3,,0.002,0.001,487.524,0.0593,0.082,0.0381,8200.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-14",24,24,800,,0.002,0.001,477.3,0.0593,0.053,0.0133,8032.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-15",21,19.87,655.02,,0.002,0.001,392.642,0.0592,0.095,0.0431,6605.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-16",14,13.48,331.48,,0.001,0.001,218.408,0.0594,0.07,0.0605,3673.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-17",24,24,802,,0.002,0.001,481.5,0.0593,0.053,0.0131,8099.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-18",24,23.25,952.75,,0.003,0.001,539.875,0.0592,0.08,0.0512,9088.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-19",15,14.09,410.25,,0.001,0.001,256.689,0.0597,0.083,0.0879,4312.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-20",8,5.73,121.48,,0,0.001,84.914,0.059,0.052,0.3814,1429.541,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-21",6,4.69,100.05,,0,0.001,71.255,0.0593,0.05,0.1913,1198.609,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-22",14,13.18,414.7,,0.001,0.001,257.286,0.0594,0.062,0.1232,4325.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-23",11,8.87,266.46,,0.001,0.001,168.115,0.0593,0.068,0.228,2829.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-24",10,9.27,208.86,,0.001,0.001,145.734,0.0592,0.05,0.1151,2453.757,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-25",12,10.25,290.29,,0.001,0.001,186.643,0.0593,0.064,0.2126,3138.709,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-26",11,8.79,242.92,,0.001,0.001,156.676,0.0594,0.076,0.2857,2636.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-27",7,6.9,213.4,,0.001,0.001,133.94,0.0596,0.053,0.0541,2252.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-28",12,10.04,271.9,,0.001,0.001,177.519,0.0595,0.076,0.296,2984.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-29",11,9.24,241.92,,0.001,0.001,161.528,0.0593,0.062,0.2821,2717.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-30",10,8.22,195.78,,0.001,0.001,135.924,0.0595,0.054,0.2706,2286.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-08-31",10,9.15,212.13,,0.001,0.001,149.055,0.0595,0.092,0.1061,2507.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-01",24,24,538,,0.002,0.001,373.9,0.0592,0.044,0.0138,6294.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-02",21,20.87,482.4,,0.002,0.001,333.676,0.0592,0.048,0.018,5613.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-03",9,7.47,189.9,,0.001,0.001,128.242,0.0593,0.054,0.1908,2157.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-04",12,11.3,321.9,,0.001,0.001,206.07,0.0593,0.062,0.0919,3467.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-05",19,17,416.48,,0.001,0.001,277.992,0.0592,0.075,0.1398,4679.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-06",14,13.12,292.8,,0.001,0.001,203.1,0.0594,0.057,0.1393,3417.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-07",14,11.83,367.63,,0.001,0.001,228.069,0.0594,0.137,0.2113,3835.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-08",2,1.08,22,,0,0.001,15.388,0.059,0.007,0.6455,259.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-10",5,3.74,75.72,,0,0.001,55.284,0.0592,0.051,0.4036,930.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-11",5,3.25,68.5,,0,0.001,49.7,0.0592,0.048,0.598,835.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-12",8,6.33,160.24,,0.001,0.001,108.69,0.0595,0.052,0.3255,1828.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-14",15,13.68,449.7,,0.001,0.001,281.78,0.0594,0.075,0.1146,4740.144,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-15",9,7.92,304.6,,0.001,0.001,179.818,0.0594,0.061,0.167,3024.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-16",9,6.58,185.9,,0.001,0.001,121.718,0.0594,0.142,0.3768,2047.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-17",8,6.96,253.64,,0.001,0.001,151.956,0.0593,0.062,0.2081,2557.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-18",12,10.64,253.78,,0.001,0.001,173.724,0.0593,0.062,0.1194,2922.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-19",5,3.79,119.88,,0,0.001,74.907,0.059,0.062,0.342,1260.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-20",4,3.29,78.85,,0,0.001,54.226,0.059,0.052,0.1513,913.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-21",7,5.85,257.68,,0.001,0.001,149.649,0.0594,0.07,0.1449,2516.509,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-22",8,7.07,152.47,,0.001,0.001,110.225,0.0591,0.055,0.1808,1854.999,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-23",8,6.32,155.62,,0.001,0.001,107.196,0.0594,0.054,0.3191,1802.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-24",8,6.68,156.21,,0.001,0.001,109.636,0.0594,0.053,0.1468,1843.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-25",8,6.99,146.19,,0.001,0.001,107.108,0.0596,0.061,0.1355,1800.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-26",7,5.24,124.52,,0,0.001,86.98,0.0591,0.05,0.3687,1464.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-27",9,7.55,182.65,,0.001,0.001,125.759,0.0594,0.056,0.2041,2114.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-28",4,3.32,81.16,,0,0.001,55.812,0.0595,0.063,0.1535,938.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-29",9,8.42,262.44,,0.001,0.001,162.568,0.0593,0.074,0.0978,2735.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-09-30",6,4.53,106.85,,0,0.001,73.705,0.0593,0.071,0.184,1240.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-01",6,4.86,106.38,,0,0.001,74.416,0.0592,0.048,0.2798,1254.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-02",4,2.3,51.5,,0,0.001,36.36,0.0593,0.043,0.697,612.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-03",3,1.55,44.7,,0,0.001,29.82,0.0593,0.055,0.5337,501.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-04",10,10,264,,0.001,0.001,176.2,0.0596,0.07,0.0425,2962.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-05",14,12.66,385.58,,0.001,0.001,243.637,0.0592,0.083,0.0716,4099.087,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-06",8,6.97,194.24,,0.001,0.001,125.568,0.0594,0.08,0.2504,2111.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-07",11,9.8,233.22,,0.001,0.001,160.616,0.0594,0.057,0.0887,2702.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-08",19,18.02,433,,0.001,0.0009,295.938,0.0594,0.085,0.0299,4978.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-09",18,15.79,356.84,,0.001,0.001,249.407,0.0593,0.082,0.1426,4196.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-10",9,7.4,188.1,,0.001,0.001,128.01,0.0594,0.054,0.2244,2152.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-12",6,4.37,99.79,,0,0.001,70.937,0.0592,0.047,0.351,1194.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-13",3,1.96,54.56,,0,0.001,36.04,0.0597,0.055,0.5127,606.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-14",8,6.14,218.27,,0.001,0.001,130.551,0.0594,0.094,0.1688,2195.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-15",8,7.25,198.25,,0.001,0.001,135.8,0.0595,0.05,0.1573,2283.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-16",6,5.18,116.4,,0,0.001,79.877,0.0592,0.019,0.029,1344.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-17",2,1.53,30.33,,0,0.001,21.984,0.06,0.044,0.2185,369.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-18",4,2.64,56,,0,0.001,39.532,0.059,0.044,0.355,666.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-19",5,3.87,144.64,,0,0.001,87.767,0.0592,0.066,0.149,1476.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-20",11,9.97,213.5,,0.001,0.001,149.988,0.0593,0.058,0.1364,2524.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-21",6,5.05,115.8,,0,0.001,80.655,0.0597,0.056,0.148,1355.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-22",6,5.58,119.38,,0,0.001,84.242,0.0593,0.057,0.0908,1417.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-23",5,3,64.66,,0,0.001,46.473,0.059,0.072,0.4286,782.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-27",5,4.55,196.96,,0.001,0.001,112.773,0.0592,0.091,0.132,1897.617,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-28",2,1.17,21.92,,0,0.001,16.416,0.059,0.049,0.3125,276.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-02",3,1.77,38.11,,0,0.001,27.334,0.059,0.054,0.3603,460.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-03",2,1.56,55.88,,0,0.001,33.36,0.0595,0.074,0.2955,561.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-04",5,3.89,105.87,,0,0.001,68.996,0.0592,0.062,0.1876,1161.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-05",6,4.7,116.44,,0,0.001,77.87,0.0593,0.069,0.2902,1310.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-06",3,1.88,36.8,,0,0.001,27.01,0.0597,0.048,0.4783,454.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-09",6,3.65,97.06,,0,0.001,63.733,0.0592,0.205,0.6607,1073.219,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-10",2,1.35,29.55,,0,0.001,20.73,0.06,0.059,0.43,347.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-11",4,3.4,68.84,,0,0.001,49.296,0.0593,0.058,0.155,829.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-14",16,14.68,305.54,,0.001,0.001,220.398,0.0595,0.079,0.0999,3707.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-15",12,11.9,314,,0.001,0.001,211.31,0.0597,0.063,0.0426,3551.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-16",21,20.1,432.2,,0.002,0.001,311.91,0.0593,0.042,0.0582,5247.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-17",13,11.85,248.35,,0.001,0.001,180.74,0.0593,0.071,0.1295,3041.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-20",2,1.31,35.31,,0,0.001,23.9,0.059,0.074,0.4415,402.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-21",6,4.35,88.39,,0,0.001,65.357,0.0593,0.059,0.4395,1099.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-22",13,12.1,310.96,,0.001,0.001,210.202,0.0591,0.079,0.1242,3539.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-24",3,1.35,49.66,,0,0.001,29.831,0.059,0.071,0.682,502.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-26",14,12.39,260.46,,0.001,0.001,191.254,0.0595,0.075,0.171,3217.652,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-27",13,11.88,247.88,,0.001,0.001,181.956,0.0592,0.071,0.1379,3065.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-28",14,12.32,276.06,,0.001,0.001,196.952,0.0592,0.076,0.2178,3313.662,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-29",14,12.28,278.4,,0.001,0.001,198.528,0.0594,0.069,0.2081,3339.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-11-30",3,2.38,90.08,,0,0.001,54.866,0.059,0.059,0.1647,923.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-01",19,18.52,467.04,,0.002,0.001,319.16,0.0592,0.109,0.062,5372.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-02",4,2.02,71.76,,0,0.001,42.443,0.0593,0.073,0.5835,714.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-03",4,3.08,96.7,,0,0.001,59.496,0.0593,0.075,0.2465,999.987,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-04",8,6.15,221.99,,0.001,0.001,130.332,0.0594,0.144,0.3761,2193.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-05",4,2.97,80.37,,0,0.001,51.647,0.059,0.055,0.2585,870.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-06",2,1.5,28.56,,0,0.001,21.33,0.0595,0.063,0.3375,358.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-10",8,6.68,135.44,,0,0.001,98.472,0.0591,0.031,0.1444,1658.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-11",10,8.88,303.44,,0.001,0.001,182.736,0.0592,0.081,0.1637,3076.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-12",3,2.65,102.49,,0,0.001,59.768,0.0593,0.085,0.1993,1005.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-19",5,2.47,75.27,,0,0.001,47.435,0.0592,0.384,1.3054,798.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-27",3,1.81,41.83,,0,0.001,28.629,0.059,0.08,0.3743,482.091,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-28",3,1.8,71.3,,0,0.001,42.77,0.0593,0.139,0.681,719.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Yuba City Energy Center",10349,"2",,"2020-12-31",3,1.57,36.43,,0,0.001,25.824,0.0593,0.11,0.6327,434.509,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-04",15,13.97,305.92,,0.001,0.001,266.116,0.0592,0.043,0.0371,4478.898,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-05",6,5.07,95.94,,0,0.001,66.25,0.0593,0.013,0.023,1116.108,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-13",4,2.9,55.96,,0,0.001,46.165,0.059,0.015,0.0825,776.718,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-27",7,5.87,124.59,,0.001,0.001,109.542,0.0594,0.016,0.046,1843.133,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-04",7,5.78,125.99,,0.001,0.001,111.898,0.0591,0.018,0.0513,1883.722,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-23",7,5.75,124.54,,0.001,0.001,109.652,0.0591,0.013,0.0391,1844.29,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-14",7,5.7,123.22,,0.001,0.001,108.815,0.0594,0.012,0.0394,1831.289,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-15",8,6.49,140.68,,0.001,0.001,125.084,0.0593,0.007,0.0085,2105.792,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-17",8,5.82,125.63,,0.001,0.0009,112.97,0.0645,0.012,0.0316,1899.89,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-18",10,8.77,199.68,,0.001,0.001,179.627,0.0593,0.008,0.0157,3020.574,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-19",7,5.75,126.05,,0.001,0.001,111.885,0.0593,0.012,0.0269,1881.59,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-20",10,8.75,201.28,,0.001,0.001,178.811,0.0594,0.01,0.0177,3009.665,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-21",8,6.74,149.4,,0.001,0.001,132.66,0.0593,0.011,0.0224,2232.973,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-28",7,5.63,118.29,,0.001,0.001,102.31,0.0593,0.022,0.0643,1722.117,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-09-30",7,5.62,118.59,,0.001,0.001,104.666,0.0593,0.011,0.0389,1760.226,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-01",7,5.35,113.61,,0,0.001,98.181,0.0593,0.008,0.0109,1651.44,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-02",7,5.34,113.32,,0,0.001,97.112,0.0594,0.008,0.011,1635.356,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-16",7,5.7,122,,0.001,0.001,104.155,0.0591,0.015,0.0537,1752.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Kingsburg Cogen Facility",10405,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-15",3,2,62.5,,0,0.001,51.6,0.06,0.054,0.1127,866.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-21",2,1,0,,0,0.001,25.8,0.06,0.006,0.0265,433.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-01",1,0.5,2,,0,0.001,12.85,0.059,0.094,0.869,216.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-16",22,21.25,934,,0.003,0.001,548.25,0.059,0.649,0.1655,9218.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-17",9,8.25,339,,0.001,0.001,212.85,0.059,0.017,0.0093,3578.85,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-01",7,6,246.5,,0.001,0.001,154.2,0.059,0.388,0.2611,2595.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-02",11,10,432.25,,0.001,0.001,257,0.059,0.023,0.0111,4326,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-10",3,2.25,57.75,,0,0.001,57.825,0.059,0.066,0.1063,973.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-11",1,0.5,0,,0,0.001,12.85,0.059,0.094,0.869,216.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-27",11,10,407.5,,0.001,0.001,223.075,0.0593,1.63,0.869,3751.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-28",7,5.75,225.25,,0.001,0.001,123.725,0.0593,0.201,0.2547,2082.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-02",11,10,377.5,,0.001,0.001,209.625,0.0595,0.018,0.0124,3525.675,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-03",12,10.5,438,,0.001,0.001,238.45,0.0593,0.035,0.0192,4012.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-04",7,6.5,257.5,,0.001,0.001,141.05,0.0594,0.025,0.025,2372,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-15",9,7.75,317,,0.001,0.001,174.875,0.059,0.802,0.5026,2943.85,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-21",9,7.5,294,,0.001,0.001,161.775,0.0591,0.013,0.0124,2721.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-22",12,10.5,438.5,,0.001,0.001,238.525,0.0592,0.033,0.0193,4015.575,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-23",8,6.5,247.5,,0.001,0.001,138.275,0.0594,0.012,0.013,2326.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-24",12,11,405.75,,0.001,0.001,224.85,0.0592,0.018,0.011,3785.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-25",11,9.75,401.75,,0.001,0.001,218.9,0.0591,0.032,0.0192,3685.175,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-26",13,12.25,463.5,,0.001,0.001,256.55,0.0591,0.034,0.0182,4318.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-27",12,10.5,418.5,,0.001,0.001,229.475,0.0594,0.03,0.0172,3860.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-28",7,6.25,233,,0.001,0.001,129,0.0593,0.032,0.0347,2172.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-29",9,7.5,287.75,,0.001,0.001,159.275,0.0592,0.031,0.027,2679.625,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-02",7,6,228.5,,0.001,0.001,126.475,0.0591,0.033,0.0336,2128.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-03",8,6.75,276.25,,0.001,0.001,152.075,0.0593,0.032,0.0279,2559.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-04",7,5.5,218,,0.001,0.001,120.075,0.0593,0.03,0.0329,2020.525,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-05",8,6.5,261,,0.001,0.001,143,0.0594,0.031,0.0296,2407.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-06",9,7.5,300.75,,0.001,0.001,165.475,0.0591,0.032,0.0274,2784.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-09",7,6,227,,0.001,0.001,126.025,0.0591,0.034,0.0349,2120.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-10",9,7.5,295,,0.001,0.001,162.725,0.0596,0.032,0.0343,2738.025,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-11",10,8.5,352,,0.001,0.001,192.975,0.0592,0.036,0.0255,3248.525,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-12",11,10.25,437.5,,0.001,0.001,238.125,0.0593,0.037,0.0206,4006.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-13",15,12.75,508.25,,0.001,0.001,278.825,0.0594,0.022,0.0111,4690.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-14",7,5.5,209.25,,0.001,0.001,115.6,0.059,0.01,0.013,1945.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-15",9,8.25,320.25,,0.001,0.001,176.125,0.0591,0.023,0.0319,2965.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-16",9,7.75,293,,0.001,0.001,162.025,0.0591,0.03,0.0256,2727.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-17",10,8.75,344,,0.001,0.001,189,0.0591,0.034,0.0228,3180.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-18",9,7.5,291.5,,0.001,0.001,160.15,0.0592,0.014,0.0182,2695.325,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-19",11,10.25,409,,0.001,0.0009,224.9,0.0593,0.035,0.0225,3783.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-20",11,9.75,388,,0.001,0.001,212.7,0.0592,0.031,0.0223,3580.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-21",11,10.25,408,,0.001,0.001,223.75,0.0592,0.042,0.0295,3765.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-22",11,9.75,397,,0.001,0.001,216.175,0.0592,0.019,0.0145,3637.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-23",12,11.25,451,,0.001,0.001,246.775,0.0591,0.038,0.0238,4152.475,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-24",11,9.5,388,,0.001,0.001,212.4,0.0591,0.034,0.0247,3572.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-25",9,7.5,299.5,,0.001,0.001,164.575,0.0592,0.032,0.0287,2769.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-26",11,10.25,418,,0.001,0.001,227.875,0.059,0.035,0.0233,3836.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-27",24,23.25,1007.5,,0.003,0.001,544.075,0.0595,0.041,0.0095,9149.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-28",11,9.5,384.75,,0.001,0.001,210.8,0.0593,0.035,0.0263,3545.175,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-29",11,9.5,384.5,,0.001,0.001,210.325,0.0593,0.034,0.0225,3537.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-30",12,10.5,424.75,,0.001,0.001,232.625,0.0592,0.036,0.0226,3914.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-07-31",12,10.75,435.5,,0.001,0.001,237.95,0.0596,0.02,0.0127,4002.075,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-01",11,10,403.25,,0.001,0.001,221.125,0.0592,0.019,0.0137,3722.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-02",9,8.25,330,,0.001,0.001,181.075,0.059,0.033,0.0276,3048.925,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-03",14,12.5,493.5,,0.001,0.001,271.35,0.0593,0.022,0.0144,4566.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-04",10,8.75,348,,0.001,0.001,190.75,0.0593,0.018,0.0152,3209.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-05",7,6,229.5,,0.001,0.001,127.65,0.059,0.012,0.017,2148.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-06",6,5.25,201,,0.001,0.001,110.85,0.0592,0.01,0.0148,1866.075,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-07",9,6.75,262.25,,0.001,0.001,144.775,0.0591,0.013,0.0152,2437.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-08",7,5.5,218.75,,0.001,0.001,120.65,0.0594,0.01,0.0143,2028.675,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-09",9,7.5,303.5,,0.001,0.001,166.475,0.0592,0.014,0.0129,2802.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-10",9,8,318.5,,0.001,0.001,175.65,0.0593,0.023,0.0334,2955.075,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-11",10,8.5,342.5,,0.001,0.0009,187.95,0.0592,0.016,0.0128,3162.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-12",9,8,323.25,,0.001,0.001,177.675,0.0592,0.015,0.0121,2990,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-13",12,11,462.25,,0.001,0.001,252.875,0.0593,0.021,0.0124,4256.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-14",14,12.5,491.5,,0.001,0.001,271.05,0.0594,0.02,0.0105,4561.675,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-15",16,14.75,626.5,,0.002,0.0009,341.325,0.0593,0.026,0.0107,5744.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-16",14,12.5,504.75,,0.001,0.0009,277.75,0.0592,0.023,0.0134,4673.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-17",16,14.5,535.75,,0.002,0.001,300.025,0.0592,0.025,0.0134,5048.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-18",16,14.5,563,,0.002,0.001,311.675,0.0593,0.039,0.018,5242.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-19",15,13.5,516.25,,0.001,0.001,285.55,0.0591,0.36,0.1271,4803.625,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-20",13,11.5,382,,0.001,0.001,219.1,0.0593,0.018,0.0151,3687.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-21",12,10.5,375,,0.001,0.001,209.975,0.0591,0.017,0.0148,3536,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-22",11,9.5,389,,0.001,0.001,214.7,0.0591,0.016,0.0124,3614.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-23",11,9.5,387.25,,0.001,0.001,213.675,0.0595,0.018,0.0137,3595.325,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-24",14,13,520.75,,0.001,0.001,288.975,0.0592,0.021,0.0117,4863.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-25",11,10.25,405,,0.001,0.0009,225.7,0.0595,0.028,0.019,3796.525,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-26",12,10.5,376,,0.001,0.0009,212.225,0.0593,0.503,0.3058,3569.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-27",13,12,441.25,,0.001,0.001,248.75,0.0593,0.146,0.1398,4186,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-28",10,8.5,329.5,,0.001,0.001,182.25,0.0592,0.015,0.0137,3066.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-29",9,7.5,287.75,,0.001,0.001,159.425,0.0593,0.028,0.0277,2681.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-08-31",10,8.5,317.75,,0.001,0.001,177.175,0.0591,0.016,0.0159,2984.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-01",8,7.25,283.5,,0.001,0.001,157.3,0.0591,0.025,0.0349,2646.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-02",8,7,257.75,,0.001,0.001,144.575,0.0594,0.026,0.028,2431.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-03",11,9.25,343.5,,0.001,0.001,188.65,0.0593,0.028,0.0276,3173.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-04",11,9.5,378.25,,0.001,0.001,206.225,0.0593,0.029,0.0224,3470.85,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-05",14,12.5,461,,0.001,0.001,257.7,0.0592,0.02,0.0124,4334.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-06",16,15,573.5,,0.002,0.001,317.425,0.0593,0.023,0.0106,5340.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-07",11,9.5,355,,0.001,0.001,197.1,0.0593,0.027,0.0215,3315,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-08",13,11.5,389,,0.001,0.001,219.55,0.0591,0.017,0.0121,3695.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-09",11,9.5,355.75,,0.001,0.001,196.375,0.0594,0.034,0.0259,3304.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-10",10,8.5,333.5,,0.001,0.001,183.15,0.0592,0.017,0.0168,3080.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-16",8,7.25,290,,0.001,0.001,160.3,0.0596,0.035,0.0316,2695.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-21",9,7.5,293.25,,0.001,0.001,162.35,0.0594,0.379,0.2198,2731.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-28",12,10.75,445.5,,0.001,0.001,242.1,0.0593,0.02,0.0119,4072.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-29",13,12.25,503,,0.001,0.001,273.975,0.0595,0.022,0.0102,4609.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-09-30",11,8.75,328,,0.001,0.001,181.15,0.0594,0.015,0.0176,3048.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-01",13,11.5,471.25,,0.001,0.001,257.1,0.0592,0.711,0.3418,4325.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-02",11,9.75,406,,0.001,0.001,219.95,0.0592,0.148,0.1654,3701.725,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-03",13,12.25,527,,0.001,0.001,284.25,0.0592,0.021,0.0102,4782.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-04",24,24,1053,,0.003,0.001,565.7,0.0592,0.033,0.007,9517.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-05",24,24,1066,,0.003,0.001,574,0.0593,0.04,0.0083,9660.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-06",1,0.25,5,,0,0.001,3.225,0.06,0,0.012,54.075,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-08",3,2,59.25,,0,0.001,34.625,0.0593,0.004,0.0273,583.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-11",3,1.75,40.5,,0,0.001,25.1,0.0587,0.184,0.869,422.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-12",12,10.5,431,,0.001,0.001,236.7,0.0593,0.158,0.1525,3982.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-13",6,5.25,200.25,,0.001,0.001,111.85,0.0592,0.022,0.0275,1881.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-14",10,8.5,341.5,,0.001,0.001,189,0.059,0.016,0.0136,3181.725,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-15",10,9.25,385,,0.001,0.001,211.75,0.0592,0.033,0.0239,3563.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-16",13,11.75,469.5,,0.001,0.001,258.925,0.0593,0.037,0.0205,4356.525,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-17",10,8.5,336.5,,0.001,0.001,186.6,0.0596,0.015,0.0108,3140.025,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-20",9,7.5,291.5,,0.001,0.001,164.125,0.0594,0.054,0.1214,2760.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-21",8,6.75,266,,0.001,0.001,147.1,0.059,0.147,0.223,2474.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-02",11,9.5,389.75,,0.001,0.001,212.575,0.0592,0.041,0.0272,3577.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-04",10,8.75,358,,0.001,0.001,196.625,0.0593,0.045,0.1119,3308.825,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-05",9,7.5,294.75,,0.001,0.001,162.35,0.0594,0.03,0.0264,2731.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-16",8,6.5,250.75,,0.001,0.001,139.35,0.0593,0.032,0.0304,2344.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-20",1,1,8,,0,0.001,7.4,0.059,0.016,0.261,125.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-21",1,0.5,0,,0,0.001,1.6,0.06,0.001,0.106,26.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Bear Mountain Limited",10649,"GT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-10",4,2.25,54.25,,0,0.001,56.7,0.059,0.367,0.77,953.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-15",3,2.25,66.25,,0,0.001,56.7,0.059,0.367,0.77,953.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-26",4,3.75,143,,0,0.001,94.5,0.059,0.612,0.77,1588.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-27",13,12.5,521,,0.002,0.001,315,0.059,2.039,0.77,5295,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-21",2,0.5,0,,0,0.001,12.6,0.059,0.082,0.77,212.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-28",7,5.5,189,,0.001,0.001,105.225,0.0597,0.681,0.77,1769.475,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-02",8,6.5,237,,0.001,0.0009,130.875,0.059,0.848,0.77,2202.825,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-03",11,9.5,382.25,,0.001,0.001,205.3,0.0596,1.331,0.77,3455.85,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-04",7,6,223.75,,0.001,0.001,121.05,0.0593,0.784,0.77,2035.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-22",7,5.5,206.25,,0.001,0.001,114.25,0.0593,0.574,0.5649,1921.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-23",14,11,399.25,,0.001,0.0009,220.025,0.0596,0.023,0.0184,3702.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-24",7,6.25,243.5,,0.001,0.001,133.775,0.059,0.024,0.0223,2251,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-09",5,2.75,45.5,,0,0.0008,29.075,0.0602,0.03,0.1758,489.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-10",8,6,220.75,,0.001,0.0009,121.05,0.0589,0.171,0.2961,2037.75,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-19",8,6.5,242.75,,0.001,0.0009,133.5,0.0596,0.014,0.0165,2245.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-27",10,9.25,367,,0.001,0.0009,199.325,0.0596,0.019,0.0137,3352.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-28",7,5.5,211,,0.001,0.001,114.925,0.0587,0.012,0.0141,1934.675,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-29",10,8.5,340,,0.001,0.001,184.7,0.0586,0.033,0.0243,3110.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-30",7,6.75,261.25,,0.001,0.001,142.125,0.0591,0.029,0.0296,2393.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-07-31",10,8.5,335,,0.001,0.001,180.9,0.0592,0.032,0.0244,3043.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-01",8,6.5,244,,0.001,0.001,134.25,0.0595,0.028,0.03,2257.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-03",8,6.5,244,,0.001,0.001,133.375,0.0591,0.032,0.0321,2242.85,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-13",6,5,178.5,,0,0.001,99.125,0.0593,0.027,0.0345,1666.825,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-14",16,14,507.25,,0.001,0.001,279.6,0.0593,0.044,0.0314,4706.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-15",15,13.75,565.5,,0.002,0.001,305.7,0.0591,0.041,0.0191,5142.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-16",15,13.5,537.75,,0.001,0.001,292.675,0.0589,0.038,0.0185,4924.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-17",16,14.75,530.25,,0.001,0.001,293.4,0.0594,0.041,0.018,4934.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-18",16,14.5,537.25,,0.001,0.001,296.475,0.0592,0.028,0.0114,4990.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-19",13,11.5,419.5,,0.001,0.001,231.125,0.0595,0.033,0.0185,3886.375,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-20",12,10.5,338.75,,0.001,0.001,193.325,0.0591,0.033,0.023,3252.075,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-21",13,11.5,405.25,,0.001,0.001,222.7,0.0594,0.036,0.0225,3747.025,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-22",8,6.75,264.75,,0.001,0.001,144.95,0.0595,0.027,0.0245,2437.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-23",7,5.5,212,,0.001,0.001,115.275,0.0591,0.024,0.0274,1939.475,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-24",12,10.5,409,,0.001,0.001,223.3,0.0594,0.033,0.0205,3757,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-25",8,6.5,246.25,,0.001,0.001,134.275,0.0589,0.014,0.0168,2259.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-26",10,8.5,281.75,,0.001,0.0009,157.175,0.0595,0.49,0.3924,2647.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-27",12,10.5,352.25,,0.001,0.001,196.7,0.0594,0.032,0.0224,3308.325,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-28",8,6.5,242.25,,0.001,0.001,132.15,0.0593,0.025,0.0245,2224.825,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-03",7,5.75,209.25,,0.001,0.001,112.875,0.0593,0.029,0.0351,1900.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-04",8,6.5,253.75,,0.001,0.001,137.35,0.0593,0.027,0.0266,2310.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-05",14,12.5,430.75,,0.001,0.001,239.35,0.0593,0.035,0.0193,4026.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-06",16,14.5,555,,0.002,0.001,302.85,0.0591,0.029,0.0133,5097.675,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-07",8,6.5,228.5,,0.001,0.001,125.925,0.0591,0.026,0.0288,2119.325,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-08",8,6.5,205.25,,0.001,0.001,116.725,0.0591,0.025,0.0259,1965.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-09",9,7.5,276.25,,0.001,0.001,150.9,0.0591,0.031,0.0267,2541.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-28",12,10.75,422.5,,0.001,0.001,228.175,0.0592,0.038,0.0243,3841.725,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-29",13,12.25,501,,0.001,0.001,269.6,0.0592,0.04,0.0202,4536.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-09-30",13,9.75,330.25,,0.001,0.0009,179.9,0.0595,0.02,0.0832,3028.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-01",13,11.5,470.25,,0.001,0.001,251.175,0.059,0.039,0.0219,4228.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-02",11,9.5,382.25,,0.001,0.001,206.225,0.0592,0.033,0.0221,3471.325,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-03",12,10.5,426.25,,0.001,0.001,229.75,0.0591,0.034,0.0186,3867.025,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-05",14,12.75,519.5,,0.001,0.001,279.7,0.0591,0.027,0.0128,4705.725,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-06",10,9,361.5,,0.001,0.001,194.85,0.0594,0.019,0.0122,3279.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-12",8,7.25,280.5,,0.001,0.001,152.625,0.0595,0.032,0.0274,2567.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-13",7,5.5,207.25,,0.001,0.001,113.575,0.0593,0.025,0.0301,1909.825,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-14",9,7.75,304.75,,0.001,0.001,165.8,0.059,0.03,0.0243,2790.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-15",10,9.25,375.25,,0.001,0.001,203.475,0.0593,0.032,0.021,3423.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-16",12,10.5,429.25,,0.001,0.001,230.975,0.0596,0.022,0.012,3885.525,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-17",1,0.5,0,,0,0.001,0.5,0.06,0,0.016,8.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-20",9,7.5,293,,0.001,0.0009,158.275,0.0589,0.016,0.0146,2664.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-02",10,8.5,334,,0.001,0.0009,180.475,0.0573,0.019,0.015,3035.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-09",3,1.75,17,,0,0.0007,13.625,0.0657,0.018,0.0767,228.175,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-12",1,0.75,0.75,,0,0.001,0.825,0.057,0.006,0.77,14.475,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Badger Creek Limited",10650,"GT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-01",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-02",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-03",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-04",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-05",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-06",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-07",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-08",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-09",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-10",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-11",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-12",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-13",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-14",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-15",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-16",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-17",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-18",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-19",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-20",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-21",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-22",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-23",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-24",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-25",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-26",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-27",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-28",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-29",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-30",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-10-31",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-01",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-02",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-03",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-04",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-05",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-06",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-07",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-08",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-09",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-10",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-11",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-12",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-13",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-14",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-15",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-16",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-17",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-18",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-19",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-20",0,,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-22",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-24",1,0.3,0,,0.017,0.195,10.2,0.059,0.06,0.702,171.81,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-29",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-11-30",1,0.22,0,,0.012,0.195,7.48,0.059,0.044,0.702,125.994,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-01",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-02",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-03",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-04",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-05",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-06",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-07",1,0.3,0,,0.017,0.195,10.2,0.059,0.06,0.702,171.81,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-08",3,2.47,40.9,,0.138,0.195,83.98,0.059,0.497,0.702,1414.569,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-09",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-10",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-11",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-12",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-13",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-14",2,0.3,0,,0.017,0.195,10.2,0.059,0.06,0.702,171.81,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-15",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-16",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-17",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-18",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-19",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-20",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-21",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-22",1,0.28,0,,0.016,0.195,9.52,0.059,0.056,0.702,160.356,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-23",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-24",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-25",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-26",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-27",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-28",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-29",1,0.28,0,,0.016,0.195,9.52,0.059,0.056,0.702,160.356,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-30",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","E. F. Oxnard Energy Facility",10776,"GTG",,"2020-12-31",0,0,,,,,,,,,,"Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Coalinga Cogeneration Facility",50131,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-08",3,2,47.75,,0,0.001,49.4,0.059,0.037,0.0677,830.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-09",5,4.25,150,,0.001,0.001,104.975,0.059,0.357,0.4558,1768.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-10",11,10.25,377.5,,0.001,0.001,253.175,0.059,0.023,0.0108,4265.025,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-12",5,4.5,118.5,,0.001,0.001,111.15,0.059,0.037,0.0374,1872.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-02",8,6.75,239.5,,0.001,0.001,137.925,0.0591,0.874,0.753,2321,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-03",8,6.75,250.5,,0.001,0.0009,136.15,0.0516,0.116,0.1968,2293.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-04",7,6,214,,0.001,0.001,123.175,0.0593,0.022,0.0246,2072.75,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-25",8,6.75,254.5,,0.001,0.001,144.825,0.0591,0.162,0.1083,2438.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-10",7,5.5,191,,0.001,0.0009,106.7,0.0507,0.034,0.0391,1796.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-19",8,6.5,236.75,,0.001,0.001,138.4,0.0591,0.035,0.0371,2329.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-27",9,8.25,320,,0.001,0.0009,172.525,0.0583,0.035,0.03,2906.175,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-29",9,7.75,275.5,,0.001,0.0009,150.125,0.0594,0.034,0.0301,2524.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-30",8,7.25,251,,0.001,0.0009,137.6,0.0519,0.014,0.0106,2315.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-07-31",8,6.75,225,,0.001,0.0009,122.85,0.0518,0.013,0.0154,2067.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-03",7,5.5,195.25,,0.001,0.001,112.75,0.0593,0.015,0.0243,1896.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-13",12,11,425.25,,0.001,0.001,241.3,0.0591,0.047,0.0283,4062.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-14",14,12.5,477.75,,0.001,0.0009,264.9,0.0601,0.027,0.0159,4458.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-15",14,12.75,505.5,,0.001,0.001,282.825,0.0591,0.028,0.0116,4760.325,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-16",14,12.5,489.75,,0.001,0.001,275.75,0.0592,0.026,0.0119,4639.675,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-17",16,14.75,507.75,,0.001,0.001,296.9,0.0591,0.028,0.0114,5001.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-18",16,14.75,517.75,,0.001,0.0009,290.45,0.0557,0.028,0.0116,4885.925,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-19",14,12.75,447.75,,0.001,0.001,261.75,0.0594,0.025,0.0116,4402.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-20",11,9.75,301,,0.001,0.0009,172.175,0.054,0.017,0.014,2895.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-21",13,11.5,375.75,,0.001,0.0009,209.55,0.0546,0.033,0.022,3529.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-22",7,5.75,211.5,,0.001,0.001,124.075,0.0594,0.012,0.0123,2086.325,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-23",7,5.5,203,,0.001,0.0009,112.325,0.0509,0.011,0.0131,1889.75,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-24",10,8.5,323,,0.001,0.0009,177.85,0.0534,0.016,0.0114,2994.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-25",10,8.5,310,,0.001,0.001,179.175,0.0592,0.401,0.2342,3014.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-26",10,8.5,274.5,,0.001,0.0009,156.85,0.0532,0.015,0.0128,2641.625,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-27",12,10.5,344.5,,0.001,0.0009,196.175,0.0545,0.02,0.0131,3300.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-28",8,6.5,221,,0.001,0.001,135.45,0.0591,0.014,0.0129,2279.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-03",7,5.5,198.75,,0.001,0.001,115.65,0.0593,0.033,0.0393,1946.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-04",7,6,207.5,,0.001,0.001,126.65,0.0593,0.013,0.0123,2129.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-05",14,12.75,413.75,,0.001,0.001,246.125,0.0594,0.025,0.0131,4138.725,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-06",14,12.5,425,,0.001,0.001,245.425,0.0592,0.025,0.0129,4133.175,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-07",8,6.5,214.25,,0.001,0.001,127.05,0.0594,0.027,0.0265,2136.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-08",8,6.5,195.25,,0.001,0.001,118.25,0.0594,0.027,0.0278,1989.025,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-09",8,6.5,235.5,,0.001,0.001,136.8,0.0593,0.017,0.0221,2300.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-28",6,3.5,69.5,,0,0.0008,48.025,0.057,0.03,0.0457,807.925,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-29",12,11.25,443,,0.001,0.0009,243.025,0.0618,0.259,0.196,4090.475,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-09-30",11,8.75,315.75,,0.001,0.001,180.125,0.0594,0.016,0.0118,3031.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-01",12,10.75,419.75,,0.001,0.0009,229.1,0.0635,0.021,0.0109,3853.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-02",11,10,379,,0.001,0.0009,206.6,0.0536,0.02,0.0135,3480.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-03",11,10.5,423,,0.001,0.001,229.25,0.059,0.039,0.0225,3860.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-05",13,12,474,,0.001,0.0009,259.025,0.0545,0.024,0.0128,4359.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-06",10,9,345.25,,0.001,0.0009,189.15,0.0533,0.018,0.0131,3182.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-12",7,6.25,213.25,,0.001,0.0009,119.175,0.0509,0.123,0.2227,2005.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-13",6,5.25,199.5,,0.001,0.001,111.375,0.0593,0.011,0.013,1873.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-14",8,7.5,291,,0.001,0.001,160.8,0.0593,0.015,0.0125,2704.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-15",11,10.5,403,,0.001,0.0009,221.35,0.0599,0.041,0.0266,3723.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-16",12,10.5,418.75,,0.001,0.0009,228.975,0.0592,0.021,0.0127,3851.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-17",8,6.5,242.5,,0.001,0.0009,134,0.0623,0.013,0.0133,2254.675,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-20",8,6.75,247,,0.001,0.0009,136,0.0519,0.033,0.0329,2288.525,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-02",9,8.5,333,,0.001,0.001,181.7,0.0593,0.039,0.03,3056.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-22",2,1.5,12,,0,0.001,9.45,0.0595,0.013,0.1255,158.625,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-25",1,0.5,1,,0,0,1.2,0.06,0.008,0.753,20.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","McKittrick Limited",50612,"GT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sargent Canyon Cogen Facility",50864,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-01",24,24,867,,0.003,0.001,686.6,0.0593,0.046,0.008,11548.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-02",24,24,869,,0.003,0.001,685.9,0.0592,0.045,0.0078,11541,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-03",24,24,872,,0.003,0.001,688,0.0593,0.049,0.0085,11574,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-04",24,24,880,,0.003,0.001,691.7,0.0591,0.043,0.0075,11643.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-05",24,24,880,,0.003,0.001,692.4,0.0592,0.044,0.0076,11653.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-06",24,24,888,,0.004,0.001,697.6,0.0593,0.047,0.008,11733.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-07",24,24,877,,0.003,0.001,691.5,0.0593,0.05,0.0086,11631.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-08",24,24,878,,0.003,0.001,690.5,0.0592,0.048,0.0082,11617.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-09",24,24,885,,0.004,0.001,693.2,0.059,0.05,0.0085,11664.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-10",24,24,886,,0.004,0.001,695.8,0.0593,0.048,0.0082,11705,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-11",24,24,880,,0.003,0.001,693.1,0.0592,0.046,0.0079,11662.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-12",24,24,882,,0.004,0.001,695.2,0.0591,0.047,0.008,11696.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-13",24,24,882,,0.004,0.001,694.3,0.0592,0.048,0.0083,11684.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-14",24,24,886,,0.004,0.001,696.4,0.0592,0.047,0.008,11717.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-15",24,24,876,,0.003,0.001,689.7,0.059,0.044,0.0077,11608.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-16",24,24,881,,0.004,0.001,693.2,0.059,0.046,0.008,11665,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-17",24,24,889,,0.004,0.001,698,0.0591,0.05,0.0085,11746.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-18",24,24,880,,0.004,0.001,694.5,0.0592,0.05,0.0086,11685.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-19",24,24,878,,0.003,0.001,691.5,0.059,0.049,0.0084,11636.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-20",24,24,878,,0.003,0.001,688.9,0.059,0.046,0.0079,11594.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-21",24,24,875,,0.003,0.001,689.2,0.0592,0.037,0.0065,11595.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-22",24,24,869,,0.003,0.001,684.7,0.0591,0.034,0.0059,11523.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-23",24,24,863,,0.003,0.001,683.2,0.0593,0.028,0.005,11494.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-24",24,24,872,,0.003,0.001,686.8,0.0591,0.034,0.0059,11554.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-25",24,24,870,,0.003,0.001,681.7,0.0593,0.046,0.0081,11469.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-26",24,24,864,,0.003,0.001,679.3,0.0591,0.047,0.0083,11428.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-27",24,24,878,,0.003,0.001,688.3,0.059,0.048,0.0082,11584.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-28",24,24,871,,0.003,0.001,686.3,0.0591,0.045,0.0077,11549.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-29",24,24,878,,0.003,0.001,687.9,0.0592,0.049,0.0084,11574.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-30",24,24,878,,0.003,0.001,687.7,0.0591,0.045,0.0077,11571.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-01-31",24,24,871,,0.003,0.001,682,0.0591,0.046,0.008,11481,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-01",24,24,869,,0.003,0.001,681.6,0.0592,0.048,0.0084,11469.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-02",24,24,877,,0.003,0.001,686.8,0.0591,0.051,0.0088,11556.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-03",24,24,876,,0.003,0.001,687.9,0.0593,0.06,0.0103,11574.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-04",24,24,881,,0.003,0.001,692.5,0.0592,0.054,0.0093,11652.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-05",24,24,877,,0.003,0.001,691.1,0.0591,0.054,0.0093,11627.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-06",24,24,864,,0.003,0.001,681.5,0.0591,0.051,0.0089,11469.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-07",24,24,862,,0.003,0.001,680.9,0.0591,0.047,0.0082,11457.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-08",24,24,867,,0.003,0.001,686.2,0.0591,0.048,0.0084,11547,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-09",24,24,866,,0.003,0.001,683.7,0.0591,0.055,0.0095,11504.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-10",24,24,862,,0.003,0.001,680.6,0.0591,0.053,0.0093,11449.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-11",24,24,862,,0.003,0.001,683.1,0.059,0.049,0.0085,11498.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-12",24,24,859,,0.003,0.001,678.6,0.0592,0.045,0.008,11417.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-13",24,24,866,,0.003,0.001,682.1,0.0592,0.048,0.0084,11479,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-14",24,24,873,,0.003,0.001,683.2,0.0593,0.046,0.008,11492,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-15",24,24,865,,0.003,0.001,682.3,0.0591,0.046,0.008,11481.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-16",24,24,870,,0.003,0.001,684.6,0.0591,0.045,0.0079,11519,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-17",24,24,868,,0.003,0.001,684.3,0.0593,0.042,0.0073,11512.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-18",24,24,863,,0.003,0.001,679.7,0.0591,0.044,0.0078,11436.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-19",24,24,865,,0.003,0.001,682,0.0592,0.052,0.009,11478.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-20",24,24,854,,0.003,0.001,677.6,0.0592,0.049,0.0085,11402.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-21",24,24,860,,0.003,0.001,676.7,0.0593,0.049,0.0087,11384.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-22",24,24,863,,0.003,0.001,679.6,0.0591,0.042,0.0073,11436.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-23",24,24,868,,0.003,0.001,683.3,0.0593,0.045,0.0079,11495.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-24",24,24,868,,0.003,0.001,683.1,0.0591,0.041,0.0072,11497.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-25",24,24,860,,0.003,0.001,678.4,0.0591,0.041,0.0071,11416.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-26",24,24,860,,0.003,0.001,676.5,0.0592,0.032,0.0056,11383.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-27",24,24,855,,0.003,0.001,676,0.0592,0.036,0.0064,11375.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-28",24,24,845,,0.003,0.001,671,0.059,0.035,0.0062,11292.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-02-29",24,24,871,,0.003,0.001,686.4,0.0593,0.041,0.0071,11545.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-01",24,24,884,,0.004,0.001,693.9,0.0592,0.037,0.0063,11674.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-02",24,24,876,,0.003,0.001,688.9,0.0591,0.036,0.0062,11594.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-03",24,24,858,,0.003,0.001,679.2,0.0591,0.04,0.007,11430.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-04",24,24,857,,0.003,0.001,676.4,0.059,0.033,0.0058,11381.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-05",24,24,859,,0.003,0.001,679.5,0.0592,0.036,0.0063,11432.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-06",24,24,862,,0.003,0.001,679.9,0.059,0.037,0.0064,11441.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-07",24,24,867,,0.003,0.001,683.4,0.0592,0.04,0.0069,11495.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-08",24,24,873,,0.003,0.001,685.5,0.0591,0.037,0.0064,11534.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-09",24,24,858,,0.003,0.001,678.7,0.0591,0.032,0.0056,11423.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-10",24,24,869,,0.003,0.001,684.8,0.0592,0.031,0.0055,11521.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-11",24,24,856,,0.003,0.001,678.7,0.0591,0.032,0.0056,11419.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-12",24,24,854,,0.003,0.001,672.2,0.0592,0.027,0.0048,11308.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-13",24,24,858,,0.003,0.001,677,0.0592,0.028,0.005,11391.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-14",24,24,859,,0.003,0.001,678.9,0.0592,0.03,0.0053,11423.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-15",24,24,871,,0.003,0.001,682.9,0.0593,0.031,0.0053,11491.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-16",24,24,884,,0.003,0.001,689.5,0.0593,0.031,0.0054,11598.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-17",24,24,880,,0.003,0.001,687.8,0.0592,0.038,0.0065,11573.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-18",24,24,872,,0.003,0.001,684.8,0.0593,0.06,0.0105,11523.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-19",24,24,873,,0.003,0.001,684.9,0.0591,0.058,0.01,11525,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-20",24,24,877,,0.003,0.001,687.5,0.0591,0.062,0.0108,11569.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-21",24,24,875,,0.003,0.001,683.1,0.0591,0.055,0.0095,11497.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-22",24,24,865,,0.003,0.001,680.8,0.0591,0.044,0.0077,11454.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-23",24,24,869,,0.003,0.001,680.7,0.0592,0.048,0.0085,11455.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-24",24,24,869,,0.003,0.001,680.5,0.0592,0.05,0.0088,11447.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-25",24,24,882,,0.003,0.001,688.3,0.0592,0.057,0.0098,11580.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-26",24,24,887,,0.003,0.001,693.4,0.0593,0.071,0.0123,11663.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-27",24,24,875,,0.003,0.001,687.3,0.0592,0.067,0.0115,11566.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-28",11,10.49,369.11,,0.001,0.001,290.348,0.0594,0.025,0.0134,4884.485,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-29",24,24,852,,0.003,0.001,674.5,0.0591,0.041,0.0072,11351,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-30",24,24,852,,0.003,0.001,674.9,0.0592,0.042,0.0075,11354.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-03-31",24,24,843,,0.003,0.001,668.1,0.0592,0.043,0.0077,11242,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-01",24,24,852,,0.003,0.001,671.5,0.0592,0.049,0.0087,11302.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-02",24,24,861,,0.003,0.001,677.3,0.0592,0.049,0.0086,11394.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-03",24,24,863,,0.003,0.001,678.3,0.0591,0.054,0.0095,11415.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-04",24,24,852,,0.003,0.001,674.4,0.0593,0.06,0.0105,11345,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-05",24,24,849,,0.003,0.001,672.2,0.0592,0.057,0.0101,11305.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-06",24,24,864,,0.003,0.001,678.3,0.059,0.063,0.011,11415.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-07",24,24,858,,0.003,0.001,677.6,0.059,0.06,0.0106,11406,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-08",24,24,850,,0.003,0.001,671.5,0.0591,0.054,0.0096,11300.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-09",24,24,856,,0.003,0.001,674.1,0.0592,0.055,0.0096,11343.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-10",24,24,845,,0.003,0.001,667.5,0.059,0.048,0.0085,11234,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-11",24,24,847,,0.003,0.001,672.6,0.0593,0.05,0.0088,11315.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-12",24,24,854,,0.003,0.001,674,0.0591,0.051,0.009,11341.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-13",24,24,846,,0.003,0.001,669.7,0.0592,0.051,0.009,11266.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-14",24,24,837,,0.003,0.001,667,0.0592,0.056,0.0099,11224.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-15",24,24,833,,0.003,0.001,662.5,0.0592,0.057,0.0102,11149.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-16",24,24,844,,0.003,0.001,667.3,0.0593,0.053,0.0094,11229.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-17",24,24,848,,0.003,0.001,668.7,0.0592,0.052,0.0092,11253.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-18",24,24,844,,0.003,0.001,667.9,0.0593,0.054,0.0095,11237.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-19",24,24,844,,0.003,0.001,668.3,0.0592,0.054,0.0096,11243.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-20",24,24,847,,0.003,0.001,670.6,0.0593,0.054,0.0095,11278.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-21",24,24,839,,0.003,0.001,668.7,0.0591,0.053,0.0094,11255,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-22",24,24,827,,0.003,0.001,662.4,0.0593,0.048,0.0085,11145.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-23",24,24,814,,0.003,0.001,661,0.0592,0.045,0.008,11123.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-24",24,24,809,,0.003,0.001,657.2,0.0592,0.048,0.0087,11060.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-25",24,24,805,,0.003,0.001,654.9,0.0592,0.047,0.0085,11019.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-26",24,24,816,,0.003,0.001,662.2,0.0591,0.049,0.0088,11141.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-27",24,24,820,,0.003,0.001,664.1,0.0591,0.049,0.0088,11178.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-28",24,24,804,,0.003,0.001,655.6,0.0592,0.044,0.008,11029.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-29",24,24,821,,0.003,0.001,663.7,0.0593,0.045,0.0081,11167.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-04-30",24,24,820,,0.003,0.001,661,0.0592,0.052,0.0094,11119.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-01",24,24,824,,0.003,0.001,662.6,0.0591,0.056,0.0101,11149.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-02",24,24,829,,0.003,0.001,665.6,0.0592,0.05,0.009,11198.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-03",24,24,825,,0.003,0.001,667.7,0.0594,0.049,0.0087,11230.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-04",24,24,826,,0.003,0.001,668.4,0.0592,0.056,0.01,11243.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-05",24,24,828,,0.003,0.001,666.8,0.0593,0.052,0.0093,11218.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-06",24,24,812,,0.003,0.001,660.4,0.0592,0.05,0.0091,11109.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-07",24,24,808,,0.003,0.001,654.5,0.0591,0.054,0.0097,11015,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-08",24,24,791,,0.003,0.001,646.3,0.0591,0.05,0.0092,10874.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-09",24,24,807,,0.003,0.001,654.8,0.0591,0.049,0.0089,11021,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-10",24,24,823,,0.003,0.001,660.8,0.0591,0.051,0.0091,11119.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-11",24,24,825,,0.003,0.001,662.3,0.0592,0.058,0.0104,11142.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-12",24,24,823,,0.003,0.001,660.6,0.0591,0.053,0.0095,11117.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-13",24,24,828,,0.003,0.001,666.2,0.0592,0.052,0.0093,11208.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-14",24,24,821,,0.003,0.001,663.7,0.0592,0.048,0.0086,11167,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-15",24,24,817,,0.003,0.001,663,0.0592,0.054,0.0098,11155,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-16",24,24,819,,0.003,0.001,661.3,0.0593,0.066,0.0118,11124.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-17",24,24,816,,0.003,0.001,659.1,0.0591,0.062,0.0111,11094.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-18",24,24,821,,0.003,0.001,661.1,0.0591,0.066,0.0119,11123.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-19",24,24,840,,0.003,0.001,673.5,0.0591,0.073,0.0128,11337.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-20",24,24,833,,0.003,0.001,551.8,0.059,0.057,0.0123,9288.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-21",24,24,821,,0.002,0.001,459,0.0593,0.047,0.0123,7721.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-22",23,21.28,730,,0.002,0.001,406.484,0.0594,0.044,0.0148,6840.172,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-23",24,24,825,,0.002,0.001,460.4,0.0593,0.048,0.0123,7743.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-24",16,15.85,535.8,,0.002,0.001,300.01,0.0591,0.027,0.0109,5050.705,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-11",2,0.63,7.42,,0,0.001,5.708,0.058,0.011,0.1255,96.069,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-12",9,6.38,192.92,,0.001,0.0009,110.366,0.0594,0.025,0.0458,1858.095,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-13",19,17.9,539.43,,0.002,0.001,312.161,0.0593,0.036,0.0152,5253.982,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-14",24,24,806,,0.002,0.001,456.4,0.0593,0.039,0.0103,7682.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-15",24,24,781,,0.002,0.001,447.3,0.0594,0.038,0.01,7525.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-16",24,24,776,,0.002,0.001,444.9,0.0594,0.038,0.0101,7485.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-17",24,24,780,,0.002,0.001,446.9,0.0593,0.038,0.01,7522.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-18",24,24,789,,0.002,0.001,449.1,0.0592,0.042,0.0109,7559.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-19",24,24,799,,0.002,0.001,453,0.0594,0.046,0.0121,7624.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-20",24,24,781,,0.002,0.001,448,0.0592,0.048,0.0128,7540.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-21",24,24,778,,0.002,0.001,447,0.0593,0.047,0.0124,7521.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-22",24,24,786,,0.002,0.001,447.1,0.0593,0.046,0.0123,7524.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-23",24,24,797,,0.002,0.001,451.3,0.0592,0.047,0.0123,7598.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-24",24,24,783,,0.002,0.001,448.9,0.0595,0.048,0.0126,7548.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-25",24,24,770,,0.002,0.001,442.8,0.0593,0.045,0.0119,7449.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-26",24,24,769,,0.002,0.001,442.1,0.0592,0.044,0.0119,7439.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-27",24,24,776,,0.002,0.001,443.9,0.0593,0.043,0.0115,7465.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-28",24,24,766,,0.002,0.001,443.4,0.0594,0.041,0.011,7460.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-29",24,24,778,,0.002,0.001,459.9,0.0593,0.044,0.0114,7739.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-30",24,24,767,,0.002,0.001,489,0.0592,0.048,0.0117,8228.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-07-31",24,24,760,,0.002,0.001,487,0.0593,0.05,0.0123,8193,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-01",24,24,765,,0.002,0.001,490,0.0592,0.051,0.0123,8246.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-02",24,24,771,,0.002,0.001,491.5,0.0593,0.05,0.0121,8269.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-03",24,24,767,,0.002,0.001,489.1,0.0593,0.052,0.0125,8230.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-04",24,24,770,,0.002,0.001,491.4,0.0592,0.052,0.0126,8272.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-05",24,24,781,,0.003,0.001,496.7,0.0593,0.056,0.0133,8352,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-06",24,24,796,,0.003,0.001,500.5,0.059,0.059,0.014,8426.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-07",24,24,811,,0.003,0.001,505.3,0.0593,0.055,0.013,8503.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-08",24,24,812,,0.003,0.001,504.2,0.0591,0.054,0.0127,8486.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-09",24,24,803,,0.003,0.001,500.2,0.0593,0.053,0.0126,8416.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-10",24,24,780,,0.002,0.001,494.2,0.0593,0.05,0.0121,8315.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-11",24,24,803,,0.003,0.001,503,0.0592,0.051,0.0119,8466.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-12",24,24,788,,0.003,0.001,496.3,0.0593,0.048,0.0115,8353.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-13",24,24,807,,0.003,0.001,503.9,0.0593,0.051,0.012,8481.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-14",24,24,776,,0.002,0.001,489.4,0.0591,0.051,0.0125,8236,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-15",24,24,783,,0.002,0.001,491.9,0.0593,0.051,0.0124,8275.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-16",24,24,784,,0.002,0.001,494.2,0.0591,0.05,0.0121,8320.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-17",24,24,789,,0.003,0.001,495.7,0.0593,0.051,0.0121,8340.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-18",24,24,795,,0.003,0.001,500.2,0.0592,0.052,0.0123,8416.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-19",24,24,813,,0.003,0.001,507.1,0.0593,0.057,0.0133,8535,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-20",24,24,812,,0.003,0.001,506.5,0.0593,0.061,0.0143,8522.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-21",24,24,800,,0.003,0.001,502.3,0.0593,0.058,0.0138,8453.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-22",24,24,789,,0.003,0.001,497.5,0.0593,0.057,0.0136,8369.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-23",24,24,792,,0.003,0.001,495.9,0.0592,0.054,0.013,8344.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-24",24,24,788,,0.003,0.001,495.4,0.0592,0.052,0.0125,8335.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-25",24,24,808,,0.003,0.001,506.4,0.0593,0.054,0.0127,8520.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-26",24,23.1,783.2,,0.002,0.001,487.36,0.0594,0.055,0.0153,8199.59,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-27",3,2.83,90.09,,0,0.001,56.931,0.0597,0.009,0.0207,957.384,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-28",24,24,813,,0.003,0.001,507.1,0.0593,0.045,0.0104,8532.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-29",24,24,816,,0.003,0.001,507.5,0.0592,0.044,0.0102,8539.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-30",24,24,814,,0.003,0.001,505.8,0.0592,0.045,0.0105,8514.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-08-31",24,24,814,,0.003,0.001,505.3,0.0593,0.044,0.0103,8504.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-01",24,24,823,,0.003,0.001,510,0.0593,0.042,0.0098,8579.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-02",24,24,818,,0.003,0.001,506.1,0.0593,0.042,0.0098,8516.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-03",24,24,811,,0.003,0.001,504.4,0.0595,0.042,0.01,8483.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-04",24,24,804,,0.003,0.001,502,0.0593,0.043,0.0102,8445.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-05",24,24,793,,0.002,0.001,494.3,0.059,0.041,0.0098,8325.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-06",24,24,779,,0.002,0.001,488.8,0.0593,0.037,0.0091,8224.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-07",24,24,780,,0.002,0.001,490.4,0.0593,0.039,0.0095,8252.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-08",24,24,804,,0.003,0.001,502.8,0.0593,0.043,0.0101,8459.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-09",24,24,814,,0.003,0.001,566.7,0.0592,0.046,0.0097,9532.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-10",24,24,831,,0.003,0.001,659.2,0.0592,0.058,0.0104,11093.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-11",24,24,828,,0.003,0.001,655.1,0.0592,0.06,0.011,11021.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-12",24,24,809,,0.003,0.001,643.7,0.0593,0.06,0.011,10832.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-13",24,24,828,,0.003,0.001,655.5,0.0592,0.061,0.0111,11030.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-14",24,24,820,,0.003,0.001,651.1,0.059,0.06,0.0109,10956.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-15",24,24,815,,0.003,0.001,647.7,0.0592,0.059,0.0109,10898.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-16",24,24,811,,0.003,0.001,644.8,0.0591,0.058,0.0108,10850.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-17",24,24,813,,0.003,0.001,645.6,0.0591,0.058,0.0107,10863.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-18",24,24,807,,0.003,0.001,642.8,0.0591,0.056,0.0103,10816.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-19",24,24,811,,0.003,0.001,645.9,0.0593,0.057,0.0104,10865.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-20",24,24,798,,0.003,0.001,638,0.0592,0.056,0.0105,10737.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-21",24,24,798,,0.003,0.001,639.1,0.0594,0.058,0.0107,10752.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-22",24,23.02,776.62,,0.003,0.001,618.098,0.0592,0.053,0.0102,10400.282,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-23",8,7.22,226,,0.001,0.001,182.126,0.0594,0.022,0.0203,3064.756,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-24",24,24,808,,0.003,0.001,643.8,0.0593,0.058,0.0106,10833,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-25",24,24,819,,0.003,0.001,656.8,0.0591,0.067,0.0122,11054.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-26",24,24,811,,0.003,0.001,651.5,0.059,0.065,0.0118,10965,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-27",24,23.09,751.19,,0.003,0.001,609.947,0.0593,0.06,0.0118,10262.804,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-28",24,24,787,,0.003,0.001,639,0.0592,0.061,0.0114,10749.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-29",24,24,797,,0.003,0.001,647.4,0.0592,0.068,0.0125,10894.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-09-30",24,24,792,,0.003,0.001,640.4,0.0592,0.067,0.0123,10777.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-01",24,24,782,,0.003,0.001,633.5,0.0593,0.065,0.0122,10656.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-02",24,24,787,,0.003,0.001,635.2,0.0591,0.066,0.0123,10686.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-03",24,24,799,,0.003,0.001,642.2,0.0593,0.067,0.0124,10808.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-04",24,24,802,,0.003,0.001,648,0.0593,0.069,0.0126,10901.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-05",24,24,799,,0.003,0.001,646.7,0.0593,0.068,0.0124,10881.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-06",24,24,816,,0.003,0.001,656.8,0.0591,0.069,0.0125,11052.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-07",24,24,829,,0.003,0.001,665.2,0.0592,0.07,0.0125,11190.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-08",24,24,840,,0.003,0.001,672,0.0592,0.072,0.0127,11309.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-09",24,24,827,,0.003,0.001,665.6,0.0592,0.07,0.0125,11197.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-10",24,24,828,,0.003,0.001,663.6,0.0592,0.065,0.0116,11167,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-11",24,24,816,,0.003,0.001,658.8,0.0593,0.064,0.0116,11085.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-12",24,24,815,,0.003,0.001,656.5,0.0592,0.07,0.0126,11043.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-13",24,24,811,,0.003,0.001,654.1,0.0592,0.069,0.0126,11005.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-14",24,24,803,,0.003,0.001,649.1,0.0591,0.064,0.0117,10923.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-15",24,24,799,,0.003,0.001,646.7,0.0592,0.067,0.0123,10880.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-16",24,24,796,,0.003,0.001,644.2,0.059,0.067,0.0123,10841.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-17",24,24,795,,0.003,0.001,644.6,0.0593,0.066,0.0122,10847.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-18",24,24,807,,0.003,0.001,652.5,0.0593,0.065,0.0118,10979,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-19",24,24,821,,0.003,0.001,659.6,0.0592,0.066,0.012,11100.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-20",6,5.1,181,,0.001,0.001,144.03,0.059,0.017,0.0242,2423.58,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-21",12,11.25,364,,0.002,0.001,297.8,0.0593,0.035,0.0189,5008.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-22",24,24,836,,0.003,0.001,670,0.0591,0.071,0.0125,11279,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-23",24,24,826,,0.003,0.001,665.4,0.0594,0.069,0.0123,11190.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-24",24,24,832,,0.003,0.001,667.8,0.0593,0.07,0.0125,11233.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-25",24,24,834,,0.003,0.001,669.1,0.0591,0.07,0.0125,11262.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-26",24,24,854,,0.003,0.001,679.8,0.0593,0.075,0.0131,11438.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-27",24,24,854,,0.003,0.001,681.2,0.0594,0.074,0.0129,11460,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-28",24,24,845,,0.003,0.001,675.5,0.0591,0.073,0.0129,11366.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-29",24,24,845,,0.003,0.001,671.6,0.0592,0.071,0.0126,11298.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-30",21,19.8,657.74,,0.003,0.001,535.506,0.0592,0.062,0.017,9009.11,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-10-31",24,24,815,,0.003,0.001,663.1,0.0591,0.073,0.013,11160.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-01",24,24,804,,0.003,0.001,663.6,0.0593,0.07,0.0126,11165.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-02",24,24,817,,0.003,0.001,667.8,0.0591,0.073,0.013,11239.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-03",24,24,828,,0.003,0.001,675.5,0.0591,0.071,0.0125,11365.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-04",24,24,819,,0.003,0.001,673.9,0.0592,0.069,0.0121,11338.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-05",24,24,806,,0.003,0.001,669.1,0.059,0.068,0.012,11257.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-06",24,24,842,,0.003,0.001,682.8,0.0592,0.072,0.0125,11487.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-07",24,24,848,,0.003,0.001,685.5,0.0591,0.072,0.0125,11535.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-08",24,24,856,,0.003,0.001,692.5,0.0592,0.075,0.0128,11653.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-09",24,24,828,,0.003,0.001,681.2,0.0592,0.074,0.0128,11463.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-10",24,24,834,,0.003,0.001,686.8,0.059,0.071,0.0123,11559.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-11",24,24,836,,0.003,0.001,684.1,0.0592,0.066,0.0115,11510.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-12",24,24,820,,0.003,0.001,674.4,0.0592,0.062,0.011,11346.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-13",24,24,809,,0.003,0.001,669.4,0.0593,0.064,0.0113,11263,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-14",24,24,804,,0.003,0.001,665.5,0.0592,0.062,0.0111,11199.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-15",24,24,798,,0.003,0.001,664.1,0.0591,0.069,0.0123,11175.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-16",24,24,787,,0.003,0.001,657,0.0592,0.069,0.0125,11055.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-17",24,24,788,,0.003,0.001,656.4,0.059,0.067,0.0121,11046.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-18",24,24,778,,0.003,0.001,652.5,0.0592,0.059,0.0107,10976.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-19",24,24,785,,0.003,0.001,658.4,0.0592,0.07,0.0126,11077,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-20",24,24,822,,0.003,0.001,675.1,0.0592,0.078,0.0137,11359.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-21",24,24,819,,0.003,0.001,673.8,0.0591,0.075,0.0132,11341.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-22",24,24,817,,0.003,0.001,672.7,0.0592,0.073,0.0129,11316.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-23",24,24,803,,0.003,0.001,668.4,0.0593,0.08,0.0143,11243.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-24",24,24,793,,0.003,0.001,663.5,0.0592,0.079,0.0141,11163.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-25",24,24,780,,0.003,0.001,658,0.0592,0.075,0.0136,11072.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-26",24,24,784,,0.003,0.001,662.8,0.0593,0.075,0.0135,11149.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-27",24,24,785,,0.003,0.001,665,0.0591,0.079,0.014,11189.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-28",24,24,784,,0.003,0.001,662.8,0.0591,0.071,0.0127,11154.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-29",24,24,764,,0.003,0.001,653.7,0.0593,0.069,0.0125,11000.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-11-30",24,24,764,,0.003,0.001,655.1,0.059,0.069,0.0125,11026.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-01",24,24,767,,0.003,0.001,653.5,0.0593,0.073,0.0133,10995.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-02",24,24,768,,0.003,0.001,648.3,0.0591,0.076,0.0139,10911.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-03",24,24,780,,0.003,0.001,651.1,0.0592,0.069,0.0125,10956.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-04",22,21.58,689.56,,0.003,0.001,585.96,0.0592,0.069,0.014,9860.046,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-05",24,23.47,809.81,,0.003,0.001,656.606,0.0592,0.068,0.0129,11050.675,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-06",24,24,850,,0.003,0.001,682.3,0.0593,0.074,0.0129,11479.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-07",24,24,849,,0.003,0.001,679.9,0.0591,0.075,0.013,11439.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-08",24,24,842,,0.003,0.001,676.3,0.0592,0.069,0.0122,11380.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-09",24,24,833,,0.003,0.001,669,0.0592,0.07,0.0124,11254.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-10",24,24,846,,0.003,0.001,677.3,0.0592,0.069,0.0121,11397,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-11",24,24,858,,0.003,0.001,682.1,0.0591,0.071,0.0124,11474.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-12",24,24,856,,0.003,0.001,678.6,0.0593,0.068,0.0119,11416.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-13",24,24,850,,0.003,0.001,678.2,0.0591,0.07,0.0123,11413,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-14",24,24,845,,0.003,0.001,678.1,0.0591,0.071,0.0125,11410.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-15",24,24,869,,0.003,0.001,692.8,0.0591,0.075,0.0128,11658.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-16",24,24,862,,0.003,0.001,688,0.0593,0.075,0.013,11570.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-17",24,24,868,,0.003,0.001,689.9,0.0591,0.076,0.0132,11608.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-18",24,24,867,,0.003,0.001,691.9,0.0591,0.075,0.013,11644.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-19",24,24,857,,0.003,0.001,686.8,0.0592,0.081,0.014,11552.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-20",24,24,851,,0.003,0.001,684.4,0.0593,0.084,0.0145,11518.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-21",24,24,845,,0.003,0.001,680.1,0.0592,0.081,0.0141,11444.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-22",24,24,852,,0.003,0.001,682.2,0.0591,0.079,0.0138,11483.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-23",24,24,849,,0.003,0.001,681.7,0.0591,0.078,0.0136,11472.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-24",24,24,855,,0.003,0.001,680.6,0.0591,0.082,0.0144,11454.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-25",24,24,846,,0.003,0.001,675.8,0.0591,0.087,0.0152,11374.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-26",24,24,861,,0.003,0.001,685,0.0591,0.062,0.0107,11527.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-27",24,24,857,,0.003,0.001,681.9,0.0592,0.069,0.012,11472.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-28",24,24,869,,0.003,0.001,687.5,0.0593,0.075,0.013,11567.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-29",24,24,861,,0.003,0.001,688.5,0.0592,0.074,0.0128,11585.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-30",24,24,867,,0.003,0.001,690.8,0.0593,0.077,0.0132,11621.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Salinas River Cogeneration Facility",50865,"1",,"2020-12-31",24,24,862,,0.003,0.001,686.9,0.0591,0.081,0.0141,11560,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-01",24,24,1176,,0,0,1810.2,0.104,0.296,0.0341,17353.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-02",24,24,1181,,0,0,1823.1,0.104,0.298,0.0341,17477.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-03",24,24,1180,,0,0,1836.7,0.104,0.299,0.034,17609.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-04",24,24,1176,,0,0,1802.9,0.104,0.294,0.034,17281,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-05",24,24,1176,,0,0,1757.2,0.104,0.287,0.034,16846.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-06",24,24,1176,,0,0,1769.1,0.104,0.288,0.034,16961.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-07",24,24,1177,,0,0,1772.8,0.104,0.29,0.0341,16994,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-08",24,24,1183,,0,0,1816.6,0.104,0.297,0.0341,17415.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-09",24,24,1182,,0,0,1816,0.104,0.296,0.034,17411,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-10",24,24,1183,,0.001,0.0001,1809.1,0.104,0.295,0.034,17344.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-11",24,24,1176,,0,0,1797.9,0.104,0.294,0.0341,17234.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-12",24,24,1176,,0,0,1784.3,0.104,0.291,0.034,17105.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-13",24,24,1182,,0,0,1787.9,0.104,0.292,0.0341,17141.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-14",24,24,1182,,0,0,1786.8,0.104,0.291,0.034,17127.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-15",24,24,1180,,0,0,1797.2,0.104,0.293,0.034,17229.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-16",24,24,1177,,0,0,1786.7,0.104,0.292,0.0341,17126.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-17",24,24,1179,,0,0,1786.8,0.104,0.291,0.034,17132.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-18",24,24,1176,,0,0,1778.2,0.104,0.29,0.034,17047.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-19",24,24,1176,,0,0,1771.3,0.104,0.288,0.034,16980,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-20",24,24,1180,,0,0,1793.9,0.104,0.293,0.034,17198.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-21",24,24,1176,,0,0,1807.5,0.104,0.295,0.0341,17326.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-22",24,24,1179,,0,0,1814.7,0.104,0.296,0.034,17398.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-23",24,24,1183,,0,0,1815.2,0.104,0.296,0.034,17402,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-24",24,24,1182,,0,0,1823.5,0.104,0.298,0.034,17482.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-25",24,24,1176,,0,0,1827.5,0.104,0.299,0.0341,17518.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-26",19,18.95,918.85,,0,0.0001,1421.9,0.104,0.23,0.0337,13632.055,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-27",24,24,1178,,0,0,1818.9,0.104,0.298,0.0341,17437.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-28",24,24,1183,,0,0,1831.6,0.104,0.299,0.034,17559.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-29",24,24,1181,,0,0,1838.4,0.104,0.3,0.034,17623.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-30",24,24,1180,,0,0,1839.7,0.104,0.301,0.0341,17637.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-01-31",24,24,1182,,0,0,1829.8,0.104,0.298,0.034,17544.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-01",24,24,1176,,0,0,1818.2,0.104,0.297,0.034,17429.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-02",24,24,1175,,0,0,1804,0.104,0.294,0.034,17293.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-03",24,24,1184,,0,0,1807.3,0.104,0.295,0.0341,17325.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-04",24,24,1176,,0.001,0,1791.3,0.104,0.293,0.0342,17173.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-05",24,24,1182,,0.001,0,1798.8,0.104,0.294,0.034,17245.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-06",24,24,1182,,0,0,1806.1,0.104,0.295,0.034,17316,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-07",24,24,1184,,0,0,1820.4,0.104,0.297,0.034,17452.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-08",24,24,1174,,0,0,1831.1,0.104,0.3,0.0342,17557.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-09",24,24,1170,,0.001,0,1810,0.104,0.306,0.0354,17351.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-10",24,24,1180,,0,0,1827.5,0.104,0.298,0.034,17520.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-11",24,24,1184,,0.001,0,1830.8,0.104,0.299,0.034,17551.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-12",24,24,1183,,0,0,1833.1,0.104,0.299,0.034,17574.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-13",24,24,1184,,0,0,1819.1,0.104,0.296,0.034,17439.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-14",24,24,1182,,0,0,1831.3,0.104,0.299,0.034,17557.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-15",24,24,1176,,0,0,1830.6,0.104,0.299,0.034,17548.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-16",24,24,1176,,0,0,1817.9,0.104,0.297,0.034,17428,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-17",24,24,1183,,0,0,1826,0.104,0.298,0.034,17503.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-18",24,24,1183,,0,0,1817.3,0.104,0.289,0.0332,17422.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-19",24,24,1182,,0,0,1807.3,0.104,0.277,0.032,17326.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-20",24,23.83,1118.9,,0,0,1720.525,0.104,0.264,0.032,16494.35,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-21",24,24,1181,,0,0,1827.1,0.104,0.281,0.032,17516.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-22",24,24,1176,,0,0,1809.5,0.104,0.277,0.0319,17347.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-23",1,0.4,18.4,,0,0,25.56,0.086,0.004,0.026,297.12,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-24",1,0.03,0,,0,1.5,0,0,0,0,0.03,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-25",24,24,524,,0.004,0.0053,879.5,0.0836,0.147,0.037,8766.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-26",24,24,1181,,0,0,1836.9,0.104,0.282,0.032,17609.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-27",24,24,1184,,0,0,1872.2,0.104,0.288,0.0321,17946.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-28",24,24,1182,,0,0.0001,1868.9,0.104,0.287,0.032,17916.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-02-29",24,24,1176,,0,0,1842.9,0.104,0.283,0.032,17668.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-01",24,24,1176,,0,0,1819.3,0.104,0.279,0.032,17441.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-02",24,24,1182,,0,0,1850.5,0.104,0.284,0.032,17739.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-03",24,24,1185,,0,0,1854,0.104,0.285,0.0321,17774.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-04",24,24,1179,,0,0,1848.9,0.104,0.296,0.0334,17722.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-05",24,24,1178,,0,0,1854.4,0.104,0.329,0.037,17777.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-06",24,24,1178,,0,0,1843.7,0.104,0.327,0.037,17677.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-07",24,24,1173,,0,0,1827.5,0.104,0.325,0.0371,17518.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-08",24,24,1174,,0,0,1825.9,0.104,0.324,0.037,17504.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-09",24,24,1181,,0,0,1860.8,0.104,0.3,0.0336,17838.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-10",24,24,1179,,0,0,1856.8,0.104,0.285,0.032,17799.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-11",24,24,1182,,0,0,1861.8,0.104,0.286,0.0321,17849.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-12",24,24,1176,,0.005,0.0006,1851.2,0.104,0.285,0.0321,17749.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-13",24,24,1177,,0.002,0.0003,1854.1,0.104,0.285,0.0321,17774.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-14",24,24,1176,,0,0,1845.4,0.104,0.283,0.032,17691.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-15",24,24,1176,,0,0,1841.7,0.104,0.284,0.0321,17655,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-16",24,24,1178,,0,0,1844,0.104,0.283,0.032,17678,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-17",24,24,1177,,0,0,1851.5,0.104,0.285,0.0321,17746.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-18",24,24,1183,,0,0,1850.1,0.104,0.284,0.032,17735.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-19",24,24,1180,,0,0,1840.9,0.104,0.282,0.032,17650.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-20",24,24,1181,,0,0,1844.6,0.104,0.283,0.032,17684.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-21",24,24,1175,,0,0,1819.8,0.104,0.279,0.032,17444.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-22",24,24,1176,,0,0,1825.7,0.104,0.279,0.0319,17503.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-23",24,24,1179,,0,0,1848.4,0.104,0.284,0.032,17720.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-24",23,22.29,1091.11,,0,0,1700.748,0.104,0.261,0.0321,16304.217,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-25",24,24,1177,,0,0,1833.8,0.104,0.282,0.032,17582.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-26",24,24,1180,,0,0,1843.4,0.104,0.282,0.032,17671.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-27",24,24,1179,,0,0,1854.2,0.104,0.285,0.032,17775.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-28",24,24,1176,,0,0,1846.6,0.104,0.283,0.032,17702.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-29",24,24,1176,,0,0,1847.2,0.104,0.284,0.032,17705.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-30",24,24,1178,,0,0,1864,0.104,0.286,0.032,17870.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-03-31",24,24,1175,,0,0,1864.3,0.104,0.287,0.0322,17873,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-01",24,24,1180,,0,0,1852.7,0.104,0.328,0.037,17764.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-02",24,24,1179,,0,0,1857.5,0.104,0.33,0.037,17807.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-03",24,24,1179,,0.001,0,1856,0.104,0.327,0.0368,17794.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-04",24,24,1176,,0,0,1840.8,0.104,0.327,0.0371,17647.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-05",24,24,1176,,0,0,1838.5,0.104,0.326,0.037,17627.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-06",24,24,1178,,0,0,1850.5,0.104,0.329,0.0371,17738.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-07",24,24,1177,,0,0,1850.8,0.104,0.326,0.0368,17745.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-08",24,24,1176,,0,0,1848.8,0.104,0.328,0.037,17722.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-09",24,24,1180,,0,0,1862.1,0.104,0.331,0.0371,17853,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-10",24,24,1179,,0,0,1883,0.104,0.334,0.037,18052.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-11",24,24,1175,,0,0,1877.5,0.104,0.333,0.037,17998.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-12",24,24,1176,,0,0,1886.5,0.104,0.335,0.037,18084.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-13",24,24,1180,,0,0,1907.5,0.104,0.339,0.037,18285.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-14",24,24,1178,,0.001,0,1901.2,0.104,0.339,0.0372,18226.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-15",24,24,1177,,0.001,0,1894.8,0.104,0.337,0.0371,18164.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-16",24,24,1175,,0,0,1882.2,0.104,0.334,0.037,18044.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-17",24,24,1175,,0,0,1871.5,0.104,0.332,0.037,17943.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-18",24,24,1175,,0.001,0,1856.4,0.104,0.33,0.0371,17799.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-19",24,24,1176,,0.001,0,1855.8,0.104,0.329,0.037,17788.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-20",24,24,1180,,0,0,1881.4,0.104,0.334,0.037,18037.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-21",24,24,1183,,0.001,0,1895.4,0.104,0.337,0.037,18174.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-22",24,24,1184,,0.001,0.0001,1873.6,0.104,0.332,0.037,17963.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-23",24,24,1183,,0,0,1855.5,0.104,0.329,0.037,17788.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-24",24,24,1182,,0,0,1856.6,0.104,0.33,0.0371,17800.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-25",24,24,1175,,0,0,1847.8,0.104,0.327,0.037,17715.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-26",23,21.26,1028.67,,0,0.0003,1605.283,0.1021,0.285,0.0362,15398.888,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-27",24,24,1177,,0,0,1824.8,0.104,0.324,0.0371,17494.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-28",24,24,1181,,0.001,0,1854.9,0.104,0.329,0.037,17783.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-29",24,24,1182,,0,0,1837.9,0.104,0.326,0.037,17615.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-04-30",24,24,1180,,0.001,0,1828.8,0.104,0.324,0.0369,17535,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-01",24,24,1181,,0.001,0,1828,0.104,0.324,0.037,17525.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-02",24,24,1176,,0,0,1833.8,0.104,0.326,0.037,17579.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-03",24,24,1176,,0,0,1816.7,0.104,0.322,0.037,17416.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-04",19,18.92,931.08,,0.001,0.0001,1455.948,0.104,0.258,0.0369,13957.816,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-05",24,23.63,676,,0.004,0.0036,1102.632,0.0862,0.204,0.0372,10948.488,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-06",24,24,1179,,0,0,1826.9,0.104,0.324,0.037,17515.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-07",24,24,1171,,0,0,1825.9,0.104,0.325,0.0371,17504.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-08",24,24,1178,,0,0,1840.8,0.104,0.326,0.0369,17648.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-09",24,24,1176,,0,0,1813,0.104,0.321,0.037,17377.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-10",6,5.7,272.3,,0,0.0002,414.99,0.104,0.072,0.0358,3977.87,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-11",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-12",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-13",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-14",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-15",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-16",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-17",8,7.47,0,,0.003,0.0175,23.664,0.0598,0.009,0.0346,397.547,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-18",15,14.08,0,,0.007,0.0241,64.424,0.0601,0.007,0.0095,1089.044,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-19",5,4.25,18.1,,0.001,0.0036,52.725,0.079,0.005,0.0146,622.85,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-20",12,11.25,129,,0.002,0.0113,242.15,0.0753,0.042,0.0301,2537.45,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-21",24,24,1182,,0,0,1748,0.104,0.311,0.0371,16758.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-22",24,24,1183,,0,0,1768.3,0.104,0.314,0.0371,16950.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-23",24,24,1176,,0,0,1763.6,0.104,0.313,0.037,16906.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-24",24,24,1176,,0,0,1782.5,0.104,0.316,0.037,17088.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-25",24,24,1176,,0,0,1806.1,0.104,0.32,0.037,17314.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-26",24,24,1176,,0,0,1828.8,0.104,0.324,0.037,17531.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-27",24,24,1167,,0,0,1802.6,0.104,0.378,0.0438,17280.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-28",24,24,1167,,0.001,0.0001,1794.5,0.104,0.374,0.0435,17203.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-29",24,24,1176,,0,0,1784.2,0.104,0.308,0.036,17104.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-30",24,24,1176,,0,0,1764.4,0.104,0.304,0.036,16914.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-05-31",24,24,1176,,0,0,1764.1,0.104,0.304,0.036,16913.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-01",24,24,1180,,0,0,1801.9,0.104,0.311,0.036,17275.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-02",24,24,1178,,0,0,1797.5,0.104,0.31,0.036,17234.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-03",24,24,1176,,0,0,1805.3,0.104,0.311,0.036,17309.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-04",24,24,1176,,0,0,1786.3,0.104,0.308,0.036,17122.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-05",24,24,1180,,0,0,1764.8,0.104,0.305,0.0361,16918.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-06",24,24,1176,,0,0,1761.8,0.104,0.304,0.036,16888.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-07",24,24,1176,,0,0,1760.5,0.104,0.304,0.036,16877.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-08",24,24,1176,,0,0,1776.4,0.104,0.307,0.036,17030.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-09",24,24,1176,,0,0,1803.3,0.104,0.312,0.036,17288.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-10",24,24,1176,,0,0,1818.9,0.104,0.314,0.036,17438.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-11",24,24,1180,,0,0,1827,0.104,0.315,0.036,17516,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-12",24,24,1176,,0,0,1814.1,0.104,0.314,0.0361,17390.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-13",24,24,1176,,0,0,1780,0.104,0.308,0.0361,17066.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-14",24,24,1176,,0,0,1793.7,0.104,0.31,0.036,17196,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-15",24,24,1176,,0,0,1797.1,0.104,0.31,0.036,17229.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-16",24,24,1176,,0,0,1784,0.104,0.308,0.036,17101.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-17",24,24,1177,,0,0,1776.1,0.104,0.307,0.036,17027.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-18",24,24,1176,,0,0,1784.5,0.104,0.308,0.036,17108.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-19",24,24,1176,,0,0,1782.7,0.104,0.308,0.036,17090.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-20",24,24,1176,,0,0,1772.1,0.104,0.306,0.036,16987.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-21",24,24,1176,,0,0,1786.9,0.104,0.308,0.036,17129.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-22",24,24,1176,,0,0,1802.5,0.104,0.311,0.036,17283.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-23",24,24,1176,,0,0,1807.2,0.104,0.312,0.036,17325.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-24",24,24,1176,,0,0,1810.5,0.104,0.312,0.036,17356.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-25",24,24,1177,,0,0,1802.9,0.104,0.311,0.036,17284.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-26",24,24,1179,,0,0,1811.9,0.104,0.312,0.036,17371.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-27",24,24,1176,,0,0,1806.4,0.104,0.312,0.036,17318.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-28",24,24,1176,,0,0,1770.7,0.104,0.306,0.036,16976.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-29",24,24,1180,,0.002,0.0003,1790.6,0.104,0.309,0.036,17166.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-06-30",24,24,1182,,0.003,0.0004,1816.9,0.104,0.313,0.036,17419.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-01",24,24,1184,,0,0,1786.3,0.104,0.309,0.036,17125.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-02",24,24,1180,,0,0,1770.7,0.104,0.306,0.036,16975.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-03",24,24,1176,,0,0,1778.3,0.104,0.307,0.036,17047,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-04",24,24,1176,,0,0,1771,0.104,0.306,0.036,16979.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-05",24,24,1176,,0,0,1759.8,0.104,0.303,0.036,16871.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-06",24,24,1177,,0,0,1775.3,0.104,0.307,0.0361,17017.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-07",24,24,1179,,0,0,1781,0.104,0.307,0.036,17075.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-08",24,24,1176,,0,0,1775.9,0.104,0.306,0.036,17024.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-09",24,24,1176,,0,0,1780.3,0.104,0.307,0.036,17068,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-10",24,24,1179,,0,0,1787.1,0.104,0.308,0.036,17132.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-11",24,24,1176,,0,0,1775,0.104,0.306,0.036,17015.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-12",24,24,1176,,0,0,1752.4,0.104,0.302,0.036,16799.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-13",24,24,1182,,0,0,1777.5,0.104,0.307,0.036,17039.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-14",24,24,1184,,0,0,1800.6,0.104,0.311,0.036,17262.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-15",24,24,1184,,0,0,1783.7,0.104,0.308,0.036,17099.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-16",24,24,1181,,0,0,1804.1,0.104,0.312,0.036,17293.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-17",24,24,1183,,0,0,1803.1,0.104,0.311,0.036,17282.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-18",24,24,1176,,0,0,1787.1,0.104,0.311,0.0363,17131.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-19",24,24,1176,,0,0,1790.6,0.104,0.318,0.037,17166.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-20",24,24,1180,,0,0,1806.3,0.104,0.321,0.037,17317.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-21",24,24,1180,,0,0,1800.8,0.104,0.32,0.037,17263.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-22",24,24,1178,,0,0,1791,0.104,0.318,0.037,17172.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-23",24,24,1180,,0,0,1790.9,0.104,0.319,0.0372,17171.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-24",24,24,1178,,0,0,1784.7,0.104,0.317,0.037,17111,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-25",24,24,1176,,0,0,1768.4,0.104,0.314,0.037,16954.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-26",24,24,1176,,0,0,1761.9,0.104,0.312,0.037,16891.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-27",24,24,1179,,0,0,1784.8,0.104,0.317,0.037,17112.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-28",24,24,1177,,0,0,1787.3,0.104,0.317,0.037,17133.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-29",24,24,1177,,0,0,1807.7,0.104,0.321,0.037,17330.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-30",24,24,1178,,0,0,1816.1,0.104,0.322,0.037,17411.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-07-31",24,24,1176,,0,0,1792.4,0.104,0.318,0.037,17184.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-01",24,24,1176,,0,0,1782.7,0.104,0.316,0.037,17090.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-02",24,24,1176,,0,0,1788.8,0.104,0.317,0.037,17148.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-03",24,24,1183,,0,0,1812.3,0.104,0.321,0.037,17374.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-04",24,24,1184,,0,0,1817.3,0.104,0.322,0.037,17423.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-05",24,24,1184,,0,0,1815.3,0.104,0.322,0.037,17403.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-06",24,24,1182,,0,0,1813.9,0.104,0.322,0.0371,17388.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-07",24,24,1179,,0,0,1804,0.104,0.32,0.037,17296,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-08",24,24,1176,,0,0,1819.4,0.104,0.323,0.037,17444.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-09",24,24,1201,,0,0,1799.5,0.104,0.316,0.0366,17251.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-10",24,24,1183,,0,0,1803,0.104,0.32,0.037,17286.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-11",24,24,1176,,0,0.0001,1804.6,0.104,0.321,0.0371,17299.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-12",24,24,1176,,0,0,1814.8,0.104,0.322,0.037,17400.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-13",24,24,1184,,0,0,1823.3,0.104,0.323,0.037,17479.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-14",24,24,1184,,0,0,1850.8,0.104,0.327,0.0369,17742.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-15",24,24,1176,,0,0,1824.9,0.104,0.324,0.037,17496.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-16",24,24,1176,,0,0,1822,0.104,0.323,0.037,17467.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-17",24,24,1176,,0,0,1846.1,0.104,0.327,0.037,17697,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-18",24,24,1180,,0,0,1846.8,0.104,0.328,0.037,17707.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-19",24,24,1178,,0,0,1837.5,0.104,0.326,0.037,17613.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-20",24,24,1179,,0,0,1827.6,0.104,0.324,0.037,17522.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-21",24,24,1181,,0,0,1837,0.104,0.325,0.037,17610.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-22",24,24,1176,,0,0,1807.5,0.104,0.321,0.037,17329.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-23",24,24,1176,,0,0,1802.7,0.104,0.319,0.037,17281.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-24",24,24,1176,,0,0,1832,0.104,0.325,0.037,17560.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-25",24,24,1180,,0,0,1841.8,0.104,0.326,0.037,17658.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-26",24,24,1162,,0,0,1785.5,0.104,0.317,0.0371,17118.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-27",24,24,1181,,0,0,1809.2,0.104,0.321,0.037,17344.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-28",24,24,1182,,0,0,1813.2,0.104,0.322,0.037,17382.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-29",24,24,1176,,0,0,1807.4,0.104,0.321,0.037,17327.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-30",24,24,1176,,0,0,1789.4,0.104,0.317,0.037,17155.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-08-31",24,24,1182,,0,0,1803.4,0.104,0.296,0.0342,17291.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-01",24,24,1182,,0,0,1815.1,0.104,0.279,0.032,17400.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-02",24,24,1183,,0,0,1803.5,0.104,0.276,0.0319,17290.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-03",24,24,1181,,0,0,1832.2,0.104,0.262,0.0298,17566.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-04",24,24,1178,,0,0,1836.3,0.104,0.237,0.027,17605.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-05",24,24,1176,,0,0,1817.5,0.104,0.235,0.027,17422.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-06",24,24,1176,,0,0,1818.1,0.104,0.235,0.027,17430.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-07",24,24,1176,,0,0,1831.1,0.104,0.237,0.027,17553.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-08",24,24,1178,,0,0,1806.7,0.104,0.223,0.0257,17320.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-09",24,24,1181,,0,0,1823.6,0.104,0.219,0.025,17483.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-10",24,24,1181,,0,0,1827.2,0.104,0.219,0.025,17513.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-11",24,24,1178,,0,0,1820.5,0.104,0.217,0.0249,17452.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-12",24,24,1176,,0,0,1828.1,0.104,0.219,0.025,17526.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-13",24,24,1176,,0,0,1847.1,0.104,0.222,0.025,17706.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-14",24,24,1176,,0,0,1850.9,0.104,0.222,0.025,17744.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-15",24,24,1176,,0,0,1840.6,0.104,0.221,0.025,17643.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-16",24,24,1176,,0,0,1825,0.104,0.218,0.025,17496,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-17",24,24,1176,,0,0,1843.7,0.104,0.221,0.025,17675.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-18",24,24,1177,,0,0,1840.4,0.104,0.221,0.025,17641.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-19",24,24,1176,,0,0,1849.8,0.104,0.221,0.025,17733,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-20",24,24,1176,,0,0,1837.2,0.104,0.219,0.0249,17612.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-21",24,24,1176,,0,0,1859.3,0.104,0.223,0.025,17825.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-22",24,24,1180,,0,0,1852.2,0.104,0.223,0.0251,17758.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-23",24,24,1181,,0,0,1858.6,0.104,0.223,0.025,17819.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-24",24,24,1178,,0,0,1847.5,0.104,0.222,0.025,17714.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-25",24,24,1182,,0,0,1843.7,0.104,0.221,0.025,17674.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-26",24,23.83,1158.52,,0,0,1818.648,0.104,0.218,0.025,17431.436,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-27",24,24,1176,,0,0,1839.9,0.104,0.221,0.025,17640.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-28",24,24,1181,,0,0,1825.9,0.104,0.218,0.025,17501.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-29",24,24,1182,,0.003,0.0004,1853.3,0.104,0.222,0.025,17768,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-09-30",24,24,1182,,0,0,1845.9,0.104,0.221,0.025,17698.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-01",24,24,1179,,0,0,1864,0.104,0.303,0.0338,17867.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-02",24,24,1175,,0,0,1867.1,0.104,0.331,0.037,17900.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-03",24,24,1175,,0,0,1838.1,0.104,0.326,0.037,17620.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-04",11,10.32,495.6,,0,0,774.468,0.104,0.136,0.0362,7424.18,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-05",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-06",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-07",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-08",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-09",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-10",0,0,,,,,,,,,,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-11",20,19.28,307,,0.005,0.0117,500.824,0.0754,0.095,0.036,5152.552,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-12",24,24,1178,,0,0,1743.9,0.104,0.309,0.0369,16718.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-13",24,24,1184,,0,0,1772,0.104,0.315,0.037,16988.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-14",24,24,1182,,0,0,1780.1,0.104,0.315,0.037,17064.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-15",24,24,1184,,0,0,1795.8,0.104,0.318,0.037,17214.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-16",24,24,1181,,0,0,1786.3,0.104,0.317,0.037,17123.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-17",24,24,1176,,0,0,1784.1,0.104,0.317,0.037,17103.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-18",24,24,1175,,0,0,1769.8,0.104,0.315,0.0371,16967.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-19",24,24,1182,,0,0,1791.9,0.104,0.317,0.037,17178.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-20",24,24,1178,,0,0,1776.5,0.104,0.315,0.037,17030.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-21",24,24,1178,,0,0,1784.2,0.104,0.317,0.0371,17104.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-22",24,24,1179,,0,0,1755.4,0.104,0.312,0.037,16825.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-23",24,24,1182,,0,0,1743.2,0.104,0.309,0.037,16712.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-24",24,24,1176,,0,0,1746,0.104,0.31,0.037,16738,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-25",24,24,1176,,0,0,1732.7,0.104,0.308,0.037,16610.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-26",24,24,1182,,0,0,1739.9,0.104,0.308,0.037,16679.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-27",24,24,1182,,0,0,1737.3,0.104,0.308,0.037,16651.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-28",24,24,1181,,0,0,1757,0.104,0.312,0.0371,16843.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-29",24,24,1182,,0,0,1783.1,0.104,0.317,0.037,17092,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-30",24,24,1182,,0,0,1752.3,0.104,0.31,0.0369,16798.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-10-31",24,24,1176,,0,0,1737.7,0.104,0.309,0.037,16659.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-01",24,24,1167,,0,0,1716.3,0.104,0.305,0.0371,16455.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-02",24,24,1181,,0,0,1739.1,0.104,0.309,0.037,16672.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-03",24,24,1182,,0,0,1748.8,0.104,0.31,0.037,16767.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-04",24,24,1182,,0,0,1753.3,0.104,0.311,0.037,16809.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-05",24,24,1181,,0,0,1774.9,0.104,0.316,0.0372,17015.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-06",24,24,1182,,0,0,1753.7,0.104,0.311,0.037,16811.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-07",24,24,1176,,0,0,1693.8,0.104,0.301,0.0371,16237.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-08",24,24,1175,,0,0,1681.7,0.104,0.299,0.0371,16121.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-09",24,24,1181,,0,0,1667.9,0.104,0.296,0.0371,15989.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-10",24,24,1182,,0,0,1699.4,0.104,0.302,0.0371,16290.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-11",24,24,1183,,0,0,1754.1,0.104,0.31,0.0369,16817.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-12",24,24,1183,,0,0,1744.9,0.104,0.31,0.037,16727.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-13",24,24,1182,,0,0,1733.9,0.104,0.307,0.037,16619,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-14",24,24,1176,,0,0,1717.3,0.104,0.305,0.037,16464.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-15",24,24,1176,,0,0,1728.5,0.104,0.306,0.037,16570.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-16",24,24,1180,,0,0,1732.9,0.104,0.307,0.037,16612.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-17",24,24,1182,,0,0,1715.9,0.104,0.305,0.037,16449.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-18",24,24,1182,,0,0,1748.3,0.104,0.31,0.037,16760.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-19",24,24,1182,,0,0,1740.2,0.104,0.309,0.037,16683,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-20",24,24,1176,,0,0,1742.4,0.104,0.309,0.037,16706.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-21",24,24,1176,,0,0,1729.3,0.104,0.307,0.0371,16578.8,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-22",24,24,1176,,0,0,1716.1,0.104,0.305,0.037,16451.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-23",24,24,1180,,0,0,1750.4,0.104,0.31,0.037,16780.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-24",24,24,1181,,0,0,1756.3,0.104,0.312,0.037,16834.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-25",24,24,1181,,0,0,1757.3,0.104,0.312,0.037,16847.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-26",24,24,1176,,0,0,1738.1,0.104,0.308,0.037,16662.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-27",24,24,1176,,0,0,1739.2,0.104,0.309,0.037,16673.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-28",24,24,1176,,0,0,1723.2,0.104,0.306,0.0371,16520.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-29",24,24,1176,,0,0,1707.6,0.104,0.303,0.037,16370.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-11-30",24,24,1183,,0,0,1741.6,0.104,0.305,0.0365,16697.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-01",24,24,1182,,0,0,1765,0.104,0.305,0.036,16920.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-02",24,24,1182,,0,0,1776.8,0.104,0.307,0.036,17033.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-03",24,24,1183,,0,0,1777,0.104,0.307,0.036,17035.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-04",24,24,1181,,0,0,1778.9,0.104,0.307,0.036,17056.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-05",24,24,1174,,0,0,1766.1,0.104,0.305,0.0361,16931,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-06",24,24,1176,,0,0,1767,0.104,0.305,0.036,16939.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-07",24,24,1182,,0,0,1780.1,0.104,0.307,0.036,17066.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-08",24,24,1182,,0,0,1772,0.104,0.306,0.036,16987.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-09",24,24,1182,,0,0,1763.2,0.104,0.304,0.036,16903.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-10",24,24,1181,,0.002,0.0002,1772.8,0.104,0.307,0.0361,16996.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-11",24,24,1179,,0.005,0.0006,1738.4,0.104,0.299,0.0359,16664.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-12",24,24,1176,,0,0,1724,0.104,0.297,0.036,16528.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-13",24,24,1176,,0,0,1734.4,0.104,0.3,0.036,16624.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-14",24,24,1182,,0,0,1739.5,0.104,0.3,0.036,16678.3,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-15",24,24,1181,,0,0,1750.3,0.104,0.302,0.036,16779.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-16",24,24,1182,,0,0,1740.2,0.104,0.3,0.036,16683.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-17",24,24,1182,,0,0,1734,0.104,0.3,0.0361,16623.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-18",24,24,1181,,0,0,1736.2,0.104,0.3,0.036,16645.1,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-19",24,24,1176,,0,0,1690.2,0.104,0.292,0.0361,16203.6,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-20",24,24,1176,,0,0,1734.4,0.104,0.3,0.036,16626.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-21",24,24,1182,,0,0,1735.6,0.104,0.299,0.036,16639.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-22",24,24,1181,,0.001,0.0001,1739.9,0.104,0.3,0.036,16679.9,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-23",24,24,1182,,0,0,1730.5,0.104,0.299,0.036,16589.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-24",24,24,1181,,0,0,1740.4,0.104,0.3,0.036,16685.2,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-25",24,24,1176,,0,0,1720,0.104,0.296,0.036,16490,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-26",24,24,1176,,0,0,1740.1,0.104,0.3,0.036,16683.7,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-27",24,24,1176,,0,0,1714.1,0.104,0.296,0.036,16431.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-28",24,24,1181,,0,0,1714.5,0.104,0.296,0.036,16438.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-29",24,24,1182,,0,0,1730.8,0.104,0.299,0.036,16593.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-30",24,24,1183,,0,0,1749.2,0.104,0.302,0.036,16771.4,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","DTE Stockton",54238,"BIOMS1",,"2020-12-31",24,24,1177,,0,0,1749,0.104,0.302,0.036,16765.5,"Wood",,"Stoker","Wet Lime FGD","Selective Catalytic Reduction","Electrostatic Precipitator",,"ARP" "CA","Goal Line",54749,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-06",9,7.75,288.5,,0.001,0.001,153.175,0.059,0.025,0.0277,2579.608,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-02",9,7.83,331.22,,0.001,0.001,171.371,0.0594,0.021,0.0219,2882.271,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-03",9,7.7,317.57,,0.001,0.001,164.554,0.0593,0.016,0.0168,2768.883,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-04",8,7.3,289.5,,0.001,0.001,150.25,0.0591,0.012,0.0156,2528.95,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-05",1,0.53,12.72,,0,0.001,7.261,0.059,0.001,0.012,122.377,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-10",9,7.94,346.9,,0.001,0.001,180.846,0.0592,0.023,0.0224,3041.586,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-11",9,7.55,347.4,,0.001,0.001,179.195,0.0593,0.023,0.0284,3015.04,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-12",9,7.58,350.6,,0.001,0.001,180.72,0.0593,0.023,0.0239,3041.212,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-13",9,7.8,359,,0.001,0.001,184.88,0.0593,0.025,0.025,3109.84,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-27",9,7.85,319.45,,0.001,0.001,166.5,0.0592,0.018,0.0212,2804.02,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-29",9,7.7,311.38,,0.001,0.001,162.592,0.0593,0.016,0.0176,2737.668,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-30",9,7.58,341.66,,0.001,0.001,176.892,0.0592,0.018,0.0174,2977.144,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-07-31",10,8.67,391.68,,0.001,0.001,202.221,0.0593,0.027,0.0235,3402.251,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-01",9,7.5,313.5,,0.001,0.001,162.642,0.059,0.028,0.0327,2739.102,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-02",9,7.57,302.54,,0.001,0.001,156.469,0.059,0.033,0.0368,2634.406,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-03",9,7.55,318.13,,0.001,0.001,165.135,0.0596,0.029,0.0334,2776.314,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-13",9,7.62,336.47,,0.001,0.001,173.291,0.059,0.032,0.0308,2917.812,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-14",13,11.48,510.36,,0.001,0.001,261.888,0.0592,0.045,0.0292,4406.432,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-15",11,9.4,410.52,,0.001,0.001,211.792,0.0593,0.036,0.0312,3564.26,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-16",12,10.53,427.06,,0.001,0.001,218.944,0.0591,0.057,0.0395,3688.562,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-17",14,12.35,523.97,,0.001,0.001,269.872,0.0594,0.056,0.0336,4539.605,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-18",14,12.65,535.3,,0.001,0.001,276.62,0.0591,0.058,0.0308,4659.58,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-19",11,9.65,448.45,,0.001,0.001,230.855,0.0592,0.037,0.0271,3885.445,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-20",11,9.41,422.5,,0.001,0.0009,219.212,0.0593,0.036,0.0319,3689.216,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-21",9,7.32,343.4,,0.001,0.001,177.788,0.0592,0.031,0.0312,2990.415,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-22",9,7.64,317.05,,0.001,0.0009,164.622,0.0593,0.053,0.0579,2771.884,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-23",9,7.73,330.24,,0.001,0.001,171.711,0.0591,0.048,0.0367,2890.304,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-24",10,8.7,405.4,,0.001,0.001,208.58,0.0591,0.039,0.0307,3511.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-25",10,8.65,397.55,,0.001,0.001,204.855,0.0592,0.038,0.0331,3447.42,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-26",10,8.68,383.8,,0.001,0.001,199.068,0.0591,0.049,0.0378,3349.312,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-27",9,8.05,362.04,,0.001,0.001,187.577,0.0594,0.038,0.0351,3155.706,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-28",9,7.65,352.95,,0.001,0.001,182.15,0.0594,0.03,0.0277,3062.575,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-03",9,7.89,308.17,,0.001,0.001,160.913,0.0593,0.013,0.0169,2709.169,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-04",9,7.9,348.68,,0.001,0.001,180.594,0.0591,0.019,0.0178,3040.399,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-05",12,10.86,514.76,,0.001,0.001,265.341,0.0595,0.031,0.019,4460.435,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-06",11,9.66,442.26,,0.001,0.001,228.152,0.0592,0.024,0.0126,3838.024,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-07",9,7.63,301.81,,0.001,0.001,152.73,0.0591,0.227,0.1679,2570.355,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-08",9,7.67,305.43,,0.001,0.001,156.528,0.0596,0.017,0.0251,2631.885,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-16",9,7.75,347.99,,0.001,0.001,179.214,0.0591,0.027,0.0259,3017.048,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-28",9,7.78,345.12,,0.001,0.001,176.914,0.0592,0.027,0.0263,2977.086,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-29",12,10.8,509.66,,0.001,0.001,258.466,0.0592,0.033,0.0196,4352.077,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-09-30",13,11.48,520.95,,0.001,0.001,265.432,0.0592,0.034,0.0151,4466.831,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-01",12,10.7,470.33,,0.001,0.001,242.355,0.0593,0.028,0.0192,4077.313,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-02",12,10.67,457.33,,0.001,0.001,236.054,0.0594,0.022,0.0179,3970.453,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-03",10,8.67,356.65,,0.001,0.001,184.743,0.0593,0.014,0.0147,3109.11,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-12",4,3.2,112.05,,0,0.001,60.71,0.0593,0.02,0.0578,1021.995,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-13",14,12.55,538.65,,0.001,0.001,279.93,0.0593,0.025,0.0171,4711.615,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-14",10,8.65,397.58,,0.001,0.001,205.236,0.0591,0.029,0.0211,3452.871,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-15",16,14.62,668.39,,0.002,0.001,341.975,0.0593,0.045,0.0191,5752.747,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-16",9,7.53,319.71,,0.001,0.001,165.25,0.0591,0.019,0.0214,2781.232,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-17",9,7.53,318.7,,0.001,0.001,165.001,0.0591,0.023,0.0269,2774.881,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-20",9,7.63,327.41,,0.001,0.001,169.964,0.0593,0.019,0.0203,2861.599,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-02",9,7.79,304.72,,0.001,0.001,157.795,0.0597,0.017,0.0193,2652.759,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goal Line",54749,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-27",2,1.75,52.25,,0,0.001,46.2,0.059,0.307,0.79,776.475,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-28",3,2.25,55,,0,0.001,59.4,0.059,0.395,0.79,1000.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-06",6,5.5,205.5,,0.001,0.001,144.65,0.059,0.963,0.79,2438.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-07",11,10.5,425.5,,0.001,0.001,276.15,0.059,1.839,0.79,4654.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-25",3,2,43.25,,0,0.001,52.6,0.059,0.35,0.79,886.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-02",8,6.5,239,,0.001,0.001,125.2,0.059,0.832,0.79,2107,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-03",11,9.5,376.25,,0.001,0.001,194.025,0.0592,1.29,0.79,3265.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-04",6,5.5,213,,0.001,0.001,110.5,0.0592,0.734,0.79,1858.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-22",6,5.25,206.5,,0.001,0.001,107.575,0.0592,0.716,0.79,1812.075,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-23",11,10.5,415.5,,0.001,0.001,218.4,0.0593,0.834,0.4355,3674.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-24",7,5.75,201,,0.001,0.0009,107.125,0.0594,0.029,0.0389,1803.175,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-25",11,10.75,433.25,,0.001,0.001,225.2,0.0593,0.021,0.0128,3789.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-26",14,12.75,506.25,,0.001,0.001,263.775,0.0595,0.045,0.0229,4435.525,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-09",7,6,220.25,,0.001,0.0009,116.9,0.0593,0.032,0.0373,1967.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-10",7,5.75,208.5,,0.001,0.001,110.575,0.0593,0.026,0.0351,1859.925,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-12",8,6.75,251.5,,0.001,0.001,132.25,0.059,0.03,0.0325,2227.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-19",7,6.25,243,,0.001,0.001,126.75,0.0591,0.031,0.0336,2133.675,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-20",11,9.75,397,,0.001,0.001,205.875,0.0593,0.018,0.0127,3464.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-21",11,10.5,431,,0.001,0.001,223,0.0593,0.02,0.012,3753.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-22",11,10.5,421,,0.001,0.001,217.45,0.0593,0.028,0.0351,3660.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-23",1,0.5,8,,0,0.001,5.05,0.059,0.001,0.033,85,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-27",10,8.5,331.5,,0.001,0.0009,172.625,0.0593,0.029,0.0216,2906.025,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-28",9,7.75,304.75,,0.001,0.001,159.075,0.0592,0.014,0.011,2676.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-29",6,5.25,204.5,,0.001,0.001,107.075,0.0595,0.027,0.0352,1801.025,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-30",7,6.75,273,,0.001,0.001,141.4,0.0594,0.014,0.0121,2378.775,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-07-31",10,8.5,339.25,,0.001,0.001,175.45,0.059,0.03,0.0229,2953.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-01",7,6.25,239,,0.001,0.001,125.9,0.0593,0.027,0.03,2118.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-03",10,9.25,370.5,,0.001,0.001,192.825,0.0593,0.036,0.0256,3246.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-13",9,8.75,350.75,,0.001,0.001,200.65,0.0591,0.038,0.027,3375.75,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-14",15,13.5,520.25,,0.002,0.001,298.95,0.0592,0.039,0.0187,5032.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-15",15,13.5,560.25,,0.002,0.001,315.625,0.0591,0.043,0.0193,5312.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-16",15,13.5,536.5,,0.002,0.001,306.625,0.0595,0.028,0.0135,5157.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-17",16,14.75,556,,0.002,0.001,321.475,0.0592,0.046,0.0199,5410.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-18",16,14.5,552.25,,0.002,0.001,318.85,0.0593,0.043,0.0199,5365.625,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-19",13,11.5,423.25,,0.001,0.001,245.35,0.0592,0.043,0.0246,4130.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-20",12,10.5,345,,0.001,0.001,208.025,0.0593,0.021,0.0165,3501.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-21",13,11.5,422.5,,0.001,0.001,241.75,0.0593,0.042,0.0241,4066.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-22",9,8.25,338.25,,0.001,0.001,191.675,0.0592,0.019,0.0134,3225.225,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-23",7,5.5,216,,0.001,0.001,123.175,0.0594,0.014,0.0181,2072.85,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-24",10,8.5,339,,0.001,0.001,192.425,0.0595,0.51,0.2579,3236.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-25",8,7,249.5,,0.001,0.001,145.25,0.0594,0.015,0.0158,2442.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-26",11,9.5,333.5,,0.001,0.001,196.325,0.0593,0.019,0.0124,3304.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-27",12,10.5,374.25,,0.001,0.001,220.1,0.0592,0.035,0.0201,3706.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-28",8,6.75,241.75,,0.001,0.001,140.35,0.0594,0.03,0.0271,2360.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-03",8,6,215.75,,0.001,0.001,118.325,0.0595,0.031,0.0296,1989.825,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-04",6,5.5,206.5,,0.001,0.001,113.4,0.0595,0.027,0.0358,1908.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-05",14,12.5,433.5,,0.001,0.001,246.025,0.059,0.039,0.0239,4142.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-06",15,13.25,476.25,,0.001,0.001,266.2,0.0593,0.053,0.0322,4481.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-07",8,6.5,228.75,,0.001,0.001,127.6,0.0594,0.026,0.0266,2146.925,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-08",8,6.5,207.75,,0.001,0.001,118.7,0.0599,0.027,0.0276,1993.625,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-09",9,7.5,276.25,,0.001,0.001,153.125,0.0593,0.036,0.0286,2577.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-28",10,9.25,386.25,,0.001,0.001,207.85,0.0593,0.02,0.0121,3496.125,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-29",12,12,504,,0.001,0.001,270.3,0.0591,0.026,0.0117,4549.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-09-30",10,8.5,335,,0.001,0.001,182.25,0.0593,0.036,0.0247,3065.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-01",12,11.25,473,,0.001,0.001,248.375,0.0591,0.023,0.0115,4180.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-02",6,5.25,192.75,,0,0.001,94.425,0.0593,0.01,0.0158,1588.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-05",13,12.25,525.5,,0.001,0.001,232.325,0.0592,0.041,0.0207,3910.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-06",10,9,371.25,,0.001,0.001,162.525,0.0594,0.033,0.0253,2733.375,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-12",11,9.5,376.5,,0.001,0.001,151.45,0.0592,0.015,0.0151,2549.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-13",7,5.5,208,,0.001,0.001,109.9,0.0593,0.011,0.016,1848.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-14",9,7.5,294.25,,0.001,0.001,112.5,0.0592,0.012,0.016,1892.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-15",11,10,405,,0.001,0.001,221.15,0.0592,0.04,0.0262,3720.9,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-16",11,10.25,429.5,,0.001,0.001,231.15,0.059,0.041,0.0234,3890.525,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-17",7,6.25,250.5,,0.001,0.001,136.325,0.059,0.343,0.2539,2294.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-20",9,7.5,295,,0.001,0.001,160.825,0.0592,0.035,0.0283,2707.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-02",10,8.75,339,,0.001,0.001,180.975,0.0595,0.322,0.17,3045.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-16",3,2,63.5,,0,0.0003,4,0.02,0.001,0.116,67.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Live Oak Limited",54768,"GT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-18",12,9.54,1190.22,,0.003,0.001,554.85,0.059,0.387,0.0814,9337.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-19",16,15.02,3021.35,,0.006,0.001,1229.049,0.0591,0.184,0.0239,20681.709,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-20",14,13.22,2880.72,,0.006,0.001,1174.186,0.059,0.169,0.0254,19758.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-21",17,16.28,3385.22,,0.007,0.001,1375.558,0.059,0.175,0.0209,23149.782,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-22",17,16.63,3355.92,,0.007,0.001,1379.341,0.059,0.174,0.0211,23210.171,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-23",6,5.8,1120.2,,0.002,0.001,457.6,0.059,0.031,0.008,7701.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-24",1,0.28,7.84,,0,0.001,7.728,0.059,0.006,0.087,130.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-25",24,24,6050,,0.012,0.001,2438.7,0.059,0.265,0.0178,41036.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-26",24,24,6394,,0.013,0.001,2559.4,0.059,0.169,0.0079,43063.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-27",23,23,4848,,0.01,0.001,1961,0.059,0.133,0.008,32995.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-30",12,11.24,2010.67,,0.004,0.001,858.181,0.059,0.202,0.0412,14438.687,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-26",16,15.37,3541.36,,0.007,0.001,1446.66,0.0591,0.193,0.0264,24341.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-27",24,24,5510,,0.011,0.001,2224.3,0.059,0.146,0.0078,37428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-28",23,23,4629,,0.009,0.001,1870.6,0.059,0.122,0.0078,31477.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-03",17,16.53,3359.43,,0.007,0.001,1382.865,0.059,0.219,0.0292,23267.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-04",23,22.97,4607.23,,0.009,0.001,1863.048,0.059,0.126,0.0081,31353.379,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-14",3,0.42,10.44,,0,0.001,10.479,0.059,0.007,0.0873,176.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-18",15,14.27,2497.29,,0.005,0.001,1041.336,0.059,0.238,0.0401,17524.035,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-19",24,23.98,4997.68,,0.01,0.001,2003.49,0.059,0.136,0.0081,33711.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-21",17,16.53,3035.43,,0.006,0.001,1256.106,0.059,0.218,0.03,21137.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-22",24,24,5079,,0.01,0.001,2037,0.059,0.134,0.0078,34277.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-23",18,17.93,3485.94,,0.007,0.001,1424.568,0.059,0.162,0.0172,23971.265,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-24",24,24,5034,,0.01,0.001,2022.5,0.059,0.135,0.0079,34033.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-25",24,24,5028,,0.01,0.001,2021.1,0.059,0.135,0.0079,34009.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-26",23,23,5017,,0.01,0.001,2020.3,0.059,0.137,0.0081,33997.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-06",17,16.35,3087.15,,0.006,0.001,1277.18,0.059,0.215,0.0302,21490.945,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-07",24,24,4855,,0.01,0.001,1954.8,0.059,0.13,0.0079,32893.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-08",24,24,4857,,0.01,0.001,1956.9,0.059,0.13,0.0079,32926.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-09",24,24,4994,,0.01,0.001,2014,0.059,0.134,0.0079,33886,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-10",24,24,5270,,0.011,0.001,2104.8,0.059,0.14,0.0079,35415.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-11",24,24,5137,,0.01,0.001,2059,0.059,0.138,0.008,34650.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-12",24,24,4906,,0.01,0.001,1983.1,0.059,0.132,0.0079,33370.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-13",24,24,4718,,0.01,0.001,1916,0.059,0.115,0.0071,32236.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-14",24,24,4780,,0.01,0.001,1934.8,0.059,0.129,0.0079,32558.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-15",24,24,4851,,0.01,0.001,1958.3,0.059,0.13,0.0079,32952.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-16",24,24,4785,,0.01,0.001,1936.4,0.059,0.128,0.0079,32585.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-17",24,24,4889,,0.01,0.001,1972.7,0.059,0.127,0.0077,33192,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-18",24,24,5032,,0.01,0.001,2024,0.059,0.136,0.008,34058.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-19",24,24,4868,,0.01,0.001,1965.3,0.059,0.131,0.0079,33070.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-20",23,22.05,4224.65,,0.009,0.001,1726.71,0.059,0.201,0.0183,29056.31,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-21",23,22.98,4822.76,,0.01,0.001,1937.608,0.059,0.13,0.008,32602.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-26",18,17.28,3590.84,,0.007,0.001,1470.712,0.0591,0.229,0.0293,24747.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-27",24,24,5268,,0.011,0.001,2113.8,0.059,0.142,0.008,35568.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-28",24,24,5146,,0.01,0.001,2066.7,0.059,0.138,0.008,34773,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-29",24,24,5416,,0.011,0.001,2177.8,0.059,0.146,0.008,36646.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-30",24,24,5308,,0.011,0.001,2131.2,0.059,0.138,0.0077,35858.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-07-31",24,24,4938,,0.01,0.001,1994.3,0.059,0.118,0.007,33557.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-01",23,22.97,4782.14,,0.01,0.001,1940.312,0.059,0.118,0.0073,32647.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-03",16,15.15,2701.87,,0.006,0.001,1125.673,0.059,0.194,0.0305,18940.667,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-09",17,16.32,3147.28,,0.007,0.001,1293.052,0.059,0.231,0.0324,21758.108,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-10",24,24,5209,,0.011,0.001,2085.9,0.059,0.14,0.008,35102.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-11",24,24,4859,,0.01,0.001,1965.2,0.059,0.132,0.008,33065.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-12",21,20.37,4413.99,,0.009,0.001,1771.845,0.059,0.118,0.0082,29813.776,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-14",24,23.95,5872.8,,0.012,0.001,2355.97,0.059,0.193,0.0125,39645.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-15",24,24,6009,,0.012,0.001,2396.1,0.059,0.143,0.0071,40318.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-16",24,24,5988,,0.012,0.001,2391.5,0.059,0.145,0.0072,40240.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-17",23,21.65,5142.85,,0.01,0.001,2070.32,0.059,0.152,0.0126,34835.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-18",24,24,6190,,0.013,0.001,2497.1,0.059,0.148,0.007,42015.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-19",24,24,5597,,0.011,0.001,2260,0.059,0.135,0.0071,38030.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-20",24,24,4716,,0.01,0.001,1918.7,0.059,0.113,0.007,32284.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-21",24,24,5486,,0.011,0.001,2185.9,0.059,0.129,0.007,36783.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-22",24,24,5571,,0.011,0.001,2228.1,0.059,0.132,0.007,37493.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-23",24,24,5559,,0.011,0.001,2216.8,0.059,0.133,0.0071,37301.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-24",24,24,5782,,0.012,0.001,2289.7,0.059,0.149,0.0078,38531.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-25",24,24,5062,,0.01,0.001,2042.7,0.059,0.137,0.008,34374.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-26",24,24,4795,,0.01,0.001,1948.7,0.059,0.13,0.008,32788.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-27",24,24,4900,,0.01,0.001,1981.7,0.059,0.133,0.008,33345.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-28",23,22.78,4820.02,,0.01,0.001,1941.664,0.059,0.132,0.0082,32667.682,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-30",13,11.39,1438.1,,0.003,0.001,657.548,0.0591,0.343,0.0709,11065.019,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-08-31",24,24,4822,,0.01,0.001,1952.6,0.059,0.131,0.008,32851.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-01",24,24,4883,,0.01,0.001,1976.8,0.059,0.132,0.0079,33260.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-02",24,24,4820,,0.01,0.001,1955.4,0.059,0.131,0.008,32906.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-03",24,24,5293,,0.011,0.001,2120.2,0.059,0.143,0.008,35678,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-04",24,24,5630,,0.011,0.001,2248.7,0.059,0.149,0.0079,37837.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-05",24,24,5336,,0.011,0.001,2157,0.059,0.144,0.008,36299.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-06",24,24,5479,,0.011,0.001,2195.4,0.059,0.148,0.008,36941.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-07",24,24,5874,,0.012,0.001,2345.7,0.059,0.157,0.008,39465.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-08",24,24,5382,,0.011,0.001,2148.6,0.059,0.145,0.008,36154.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-09",24,24,4779,,0.01,0.001,1937.3,0.059,0.13,0.008,32600.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-10",24,24,5044,,0.01,0.001,2032.7,0.059,0.137,0.008,34206.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-11",20,20,4240,,0.009,0.001,1705,0.059,0.115,0.0081,28688.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-15",11,10.28,2144.84,,0.004,0.001,871.244,0.059,0.111,0.0259,14661.416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-16",24,24,5193,,0.011,0.001,2084.7,0.059,0.14,0.008,35078.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-17",24,24,5472,,0.011,0.001,2183.8,0.059,0.147,0.008,36744.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-18",24,24,5305,,0.011,0.001,2124.2,0.059,0.143,0.008,35749,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-19",24,24,4992,,0.01,0.001,2009.7,0.059,0.135,0.008,33819,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-20",9,7.32,1514.36,,0.003,0.001,619.25,0.059,0.089,0.03,10421.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-21",8,7.29,1402.69,,0.003,0.001,576.144,0.059,0.085,0.0276,9695.171,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-22",7,5.82,1027.96,,0.002,0.001,430.95,0.059,0.075,0.0311,7250.904,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-23",9,8.3,1516.26,,0.003,0.001,628.894,0.059,0.088,0.0248,10583.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-24",9,8.3,1902.82,,0.004,0.001,778.46,0.059,0.096,0.0247,13098.522,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-27",4,2.15,245.58,,0.001,0.001,116.467,0.0593,0.081,0.071,1960.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-28",11,9.59,2052.37,,0.004,0.001,828.117,0.0591,0.112,0.0276,13931.985,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-29",13,12.12,2625.04,,0.005,0.001,1057.832,0.0591,0.12,0.0203,17801.056,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-09-30",14,13.07,2975.69,,0.006,0.001,1188.786,0.059,0.126,0.019,20009.351,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-01",14,13.27,2969.76,,0.006,0.001,1191.251,0.059,0.126,0.0186,20046.086,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-02",13,12.26,2697.56,,0.005,0.001,1086.282,0.059,0.115,0.0191,18279.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-03",9,8.28,1776.38,,0.004,0.001,719.272,0.0591,0.092,0.0242,12104.654,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-04",8,7.28,1534.14,,0.003,0.001,627.786,0.0591,0.085,0.0258,10562.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-05",10,9.28,2129.16,,0.004,0.001,859.858,0.059,0.12,0.0284,14471.054,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-06",11,10.27,2402.89,,0.005,0.001,955.804,0.0591,0.133,0.0266,16081.805,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-07",9,7.79,1596.98,,0.003,0.001,646.557,0.059,0.103,0.031,10880.628,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-12",11,10.78,1967.16,,0.004,0.001,812.46,0.059,0.139,0.0297,13672.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-13",24,24,4931,,0.01,0.001,1998.2,0.059,0.134,0.008,33622.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-14",24,24,5132,,0.01,0.001,2068.3,0.059,0.139,0.008,34808.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-15",24,24,5493,,0.011,0.001,2186.8,0.059,0.147,0.008,36797.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-16",24,24,5060,,0.01,0.001,2040.3,0.059,0.137,0.008,34329.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-17",24,24,5031,,0.01,0.001,2033.5,0.059,0.137,0.008,34222.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-18",24,24,5354,,0.011,0.001,2139.5,0.059,0.144,0.008,36002.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-19",21,20.52,4479.08,,0.009,0.001,1796.72,0.059,0.122,0.0081,30234.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-20",9,8.3,1598.26,,0.003,0.001,657.544,0.059,0.102,0.0296,11064.448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-21",11,10.28,2259.52,,0.005,0.001,912.806,0.059,0.119,0.0244,15356.042,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-22",10,9.3,1900.38,,0.004,0.001,773.902,0.059,0.116,0.0281,13021.726,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-23",9,8.25,1613.45,,0.003,0.001,662.836,0.059,0.107,0.0293,11153.382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-26",8,7.26,1647.7,,0.003,0.001,662.536,0.059,0.116,0.0391,11147.734,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-27",11,10.3,2458.4,,0.005,0.001,979.04,0.059,0.117,0.0244,16474.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-28",17,16.22,3629.58,,0.007,0.001,1454.488,0.059,0.148,0.0175,24474.374,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-29",7,6.23,1257.4,,0.003,0.001,515.588,0.059,0.087,0.0323,8674.103,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-19",9,5.79,528.98,,0.001,0.001,277.48,0.059,0.231,0.0967,4669.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-20",12,11.38,2340.22,,0.005,0.001,952.407,0.059,0.161,0.0303,16026.422,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-01",18,16.73,3753.3,,0.008,0.001,1532.344,0.059,0.293,0.0376,25783.07,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-02",20,19.47,4775.55,,0.01,0.001,1931.585,0.059,0.19,0.0169,32501.946,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-03",16,15.65,4099,,0.008,0.001,1656.708,0.059,0.158,0.0163,27877.194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-04",20,19.3,5108.2,,0.01,0.001,2037.462,0.059,0.197,0.016,34280.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-05",24,24,6108,,0.012,0.001,2417.9,0.059,0.163,0.008,40685.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-06",24,24,5483,,0.011,0.001,2191.4,0.059,0.147,0.008,36872.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-07",24,24,5772,,0.012,0.001,2314,0.059,0.155,0.008,38939.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-08",24,24,5700,,0.011,0.001,2262.6,0.059,0.147,0.0077,38072.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-09",24,24,5693,,0.011,0.001,2258.9,0.059,0.132,0.007,38009.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-10",24,24,6237,,0.012,0.001,2464.5,0.059,0.148,0.0071,41472.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-11",24,24,6307,,0.013,0.001,2512.1,0.059,0.149,0.0071,42273.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-12",20,19.25,4771,,0.01,0.001,1933.55,0.059,0.195,0.0168,32535.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-13",24,24,6473,,0.013,0.001,2580.8,0.059,0.163,0.0075,43424.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-14",24,24,6066,,0.012,0.001,2418,0.059,0.149,0.0073,40685.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-15",24,24,6352,,0.013,0.001,2533.3,0.059,0.153,0.0072,42625.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-16",24,24,6519,,0.013,0.001,2596.9,0.059,0.155,0.0071,43697.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-17",23,21.88,4783.98,,0.01,0.001,1938.639,0.059,0.182,0.0151,32621.529,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-20",10,9.54,2135.75,,0.004,0.001,872.758,0.059,0.108,0.0254,14687.057,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-21",18,15.94,3362.55,,0.007,0.001,1369.161,0.0591,0.213,0.0238,23042.211,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-22",18,17.42,3781.6,,0.008,0.001,1542.006,0.059,0.184,0.0198,25947.07,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-23",24,24,5890,,0.012,0.001,2360.1,0.059,0.148,0.0075,39711,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-24",24,24,6081,,0.012,0.001,2410.8,0.059,0.159,0.0078,40568.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-25",17,16.07,3220.92,,0.007,0.001,1320.717,0.059,0.154,0.0178,22224.357,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-26",11,10.42,1885.1,,0.004,0.001,785.308,0.059,0.119,0.0245,13212.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-27",20,18.8,4305.85,,0.009,0.001,1720.81,0.059,0.188,0.0176,28960.575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-28",24,24,6058,,0.012,0.001,2418.7,0.059,0.157,0.0077,40699.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-29",10,9.58,2527.92,,0.005,0.001,1001.962,0.059,0.062,0.0074,16861.878,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT01",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-15",1,0.22,5.72,,0,0.001,5.566,0.059,0.002,0.049,93.808,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-18",16,15.45,2952.95,,0.006,0.001,1207.07,0.059,0.245,0.0366,20312.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-19",24,24,5054,,0.01,0.001,2016.6,0.059,0.133,0.0078,33931.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-20",24,24,5016,,0.01,0.001,2002.9,0.059,0.131,0.0078,33706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-21",23,22.97,4776.9,,0.01,0.001,1908.264,0.059,0.129,0.0081,32108.351,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-22",16,15.52,3070.08,,0.006,0.001,1246.184,0.059,0.159,0.0211,20969.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-23",20,18.44,3452.74,,0.007,0.001,1404.892,0.0591,0.138,0.0154,23642.09,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-24",22,21.98,4535.74,,0.009,0.001,1821.608,0.059,0.142,0.0095,30654.486,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-09",15,14.52,2752.6,,0.006,0.001,1134.652,0.059,0.213,0.034,19091.632,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-10",24,24,5982,,0.012,0.001,2384.6,0.059,0.16,0.008,40124.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-11",23,22.92,5550.68,,0.011,0.001,2224.78,0.059,0.153,0.0083,37437.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-10",15,14.27,3085.02,,0.006,0.001,1234.628,0.059,0.14,0.0202,20777.261,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-11",18,16.85,3501.05,,0.007,0.001,1403.025,0.059,0.117,0.0132,23610.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-12",24,24,4902,,0.01,0.001,1964.3,0.059,0.132,0.008,33052.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-13",23,22.93,4437.8,,0.009,0.001,1791.919,0.059,0.121,0.0081,30152.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-14",8,7.2,1225.82,,0.003,0.001,511.561,0.059,0.069,0.0238,8610.638,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-15",7,6.25,1062.15,,0.002,0.001,445.201,0.0591,0.071,0.028,7491.102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-16",7,6.25,1053.15,,0.002,0.001,441.095,0.059,0.05,0.0211,7420.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-17",7,6.25,1174.44,,0.002,0.001,482.518,0.059,0.063,0.0243,8119.662,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-18",3,0.85,41.25,,0,0.001,28.27,0.0593,0.019,0.0683,475.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-19",7,6.17,1131.69,,0.002,0.001,465.85,0.059,0.06,0.0256,7840.709,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-20",2,1.6,171.2,,0,0.001,82.72,0.059,0.037,0.0585,1392.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-21",7,6.81,1392.56,,0.003,0.001,562.299,0.059,0.073,0.0226,9462.409,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-22",7,6.25,1196.3,,0.003,0.001,497.37,0.059,0.124,0.0454,8370.595,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-26",7,6.23,1406.07,,0.003,0.001,571.741,0.0591,0.074,0.0287,9621.097,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-27",11,10.21,2358.36,,0.005,0.001,949.026,0.059,0.104,0.022,15970.713,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-28",10,9.28,2060.3,,0.004,0.001,826.446,0.059,0.084,0.0188,13904.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-29",4,3.32,323.32,,0.001,0.001,161.282,0.059,0.109,0.0815,2714.578,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-09",7,6.24,1342.57,,0.003,0.001,538.579,0.059,0.075,0.0289,9063.748,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-10",8,7.23,1518.4,,0.003,0.001,612.244,0.0591,0.078,0.0244,10302.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-11",7,6.25,1134.7,,0.002,0.001,469.5,0.059,0.069,0.0263,7900.815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-12",12,11.3,2480.1,,0.005,0.001,995.96,0.059,0.095,0.0178,16758.09,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-13",24,24,6066,,0.012,0.001,2413.9,0.059,0.146,0.0072,40619.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-14",24,24,6023,,0.012,0.001,2386.1,0.059,0.145,0.0072,40149.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-15",24,24,6027,,0.012,0.001,2384.8,0.059,0.145,0.0072,40133.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-16",24,24,6008,,0.012,0.001,2380.9,0.059,0.143,0.0072,40063.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-17",23,21.6,5171.25,,0.01,0.001,2067.65,0.059,0.166,0.014,34794.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-18",24,24,6097,,0.012,0.001,2405.5,0.059,0.147,0.0073,40479.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-19",24,24,5566,,0.011,0.001,2221.6,0.059,0.133,0.0071,37383.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-20",24,24,4710,,0.01,0.001,1900.1,0.059,0.113,0.0071,31973.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-21",24,24,5483,,0.011,0.001,2165.9,0.059,0.13,0.0071,36444.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-22",24,24,5558,,0.011,0.001,2197.2,0.059,0.131,0.0071,36974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-23",24,24,5555,,0.011,0.001,2195.1,0.059,0.133,0.0072,36939.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-24",24,24,5781,,0.011,0.001,2270.1,0.059,0.147,0.0077,38198.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-25",24,24,5058,,0.01,0.001,2023.1,0.059,0.136,0.008,34047.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-26",23,22.93,4560.89,,0.009,0.001,1840.339,0.059,0.124,0.008,30968.296,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-27",11,10.28,1972.82,,0.004,0.001,806.01,0.059,0.1,0.0212,13561.606,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-28",9,7.53,1494.95,,0.003,0.001,609.539,0.0591,0.079,0.0234,10257.926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-29",8,7.1,1284.4,,0.003,0.001,535.804,0.059,0.122,0.0398,9016.626,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-30",3,1.49,150.64,,0,0.001,74.216,0.059,0.019,0.0237,1248.827,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-08-31",6,5.2,855.81,,0.002,0.001,361.43,0.059,0.069,0.0363,6080.59,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-01",4,3.27,494,,0.001,0.001,215.076,0.059,0.054,0.0428,3617.398,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-03",12,11.27,2555.56,,0.005,0.001,1017.106,0.059,0.116,0.0228,17115.879,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-04",24,24,5639,,0.011,0.001,2227.6,0.059,0.15,0.008,37484.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-05",24,24,5337,,0.011,0.001,2133.3,0.059,0.142,0.0079,35902,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-06",24,24,5484,,0.011,0.001,2176.1,0.059,0.146,0.008,36617.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-07",24,24,5883,,0.012,0.001,2325.1,0.059,0.156,0.008,39121.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-08",23,22.97,5151.08,,0.01,0.001,2040.121,0.059,0.14,0.0082,34327.441,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-09",10,9.18,1590.66,,0.003,0.001,663.372,0.059,0.093,0.0237,11159.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-10",9,8.25,1404.05,,0.003,0.001,588.062,0.059,0.09,0.0264,9895.704,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-11",10,9.3,1711.1,,0.004,0.001,702.18,0.0591,0.086,0.0222,11814.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-12",24,24,5075,,0.01,0.001,2023.4,0.059,0.135,0.0079,34048.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-13",24,24,5050,,0.01,0.001,2012.9,0.059,0.135,0.008,33871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-14",24,24,5165,,0.01,0.001,2055.2,0.059,0.137,0.0079,34579.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-15",21,20.97,4549.21,,0.009,0.001,1813.124,0.059,0.123,0.008,30511.013,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-16",9,8.25,1801.56,,0.004,0.001,723.681,0.059,0.089,0.0232,12176.297,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-17",9,8.25,1852.48,,0.004,0.001,746.615,0.0591,0.093,0.0243,12562.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-18",6,5.28,988.82,,0.002,0.001,408.078,0.059,0.07,0.032,6866.374,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-20",21,20.23,4243.98,,0.009,0.001,1702.495,0.059,0.209,0.021,28649.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-21",24,24,5179,,0.01,0.001,2054,0.059,0.138,0.008,34564.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-22",24,24,5080,,0.01,0.001,2024.2,0.059,0.137,0.008,34062.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-23",24,24,4916,,0.01,0.001,1967.5,0.059,0.131,0.0079,33104.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-24",24,24,5328,,0.011,0.001,2123.9,0.059,0.142,0.0079,35738.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-25",24,24,4788,,0.01,0.001,1926.9,0.059,0.128,0.0079,32423.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-26",24,24,4836,,0.01,0.001,1943.7,0.059,0.13,0.008,32707.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-27",24,22.63,4204.59,,0.009,0.001,1726.751,0.059,0.267,0.0256,29053.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-28",24,24,5102,,0.01,0.001,2030,0.059,0.138,0.0081,34157.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-29",24,24,5207,,0.01,0.001,2066.5,0.059,0.138,0.0079,34773.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-09-30",24,24,5367,,0.011,0.001,2121.4,0.059,0.139,0.0078,35697.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-01",24,24,5289,,0.011,0.001,2095.5,0.059,0.136,0.0077,35259,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-02",24,24,5213,,0.01,0.001,2071.3,0.059,0.136,0.0078,34853.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-03",24,24,5068,,0.01,0.001,2022.6,0.059,0.135,0.008,34032.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-04",24,24,5223,,0.01,0.001,2077.9,0.059,0.14,0.008,34966.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-05",24,24,5575,,0.011,0.001,2194.9,0.059,0.146,0.0079,36932.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-06",24,24,5471,,0.011,0.001,2145.3,0.059,0.144,0.008,36098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-07",24,23.05,5284.25,,0.01,0.001,2071.575,0.059,0.135,0.0083,34858.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-12",12,8.76,1238.59,,0.003,0.001,547.008,0.059,0.228,0.0573,9203.553,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-19",12,11.28,2398.56,,0.005,0.001,965.204,0.059,0.112,0.0229,16241.324,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-20",24,24,5037,,0.01,0.001,2013.7,0.059,0.135,0.008,33886.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-21",24,24,5294,,0.011,0.001,2103.1,0.059,0.141,0.008,35386.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-22",24,24,5206,,0.01,0.001,2070.4,0.059,0.139,0.008,34837.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-23",24,24,5112,,0.01,0.001,2039.2,0.059,0.136,0.0079,34312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-24",24,24,5114,,0.01,0.001,2036.5,0.059,0.137,0.008,34267.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-25",24,24,5615,,0.011,0.001,2207.9,0.059,0.146,0.0079,37150.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-26",24,24,5562,,0.011,0.001,2191.6,0.059,0.147,0.008,36878.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-27",24,24,5675,,0.011,0.001,2233.1,0.059,0.149,0.008,37577.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-28",24,24,5372,,0.011,0.001,2128.8,0.059,0.143,0.008,35814.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-29",23,22.95,4788.9,,0.01,0.001,1918.01,0.059,0.131,0.0081,32271.415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-25",5,2.73,230.43,,0.001,0.001,125.154,0.059,0.144,0.086,2105.07,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-26",1,0.88,51.04,,0,0.001,33.44,0.059,0.026,0.091,563.376,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-27",4,3.97,417.72,,0.001,0.001,205.313,0.059,0.177,0.1065,3455.331,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-28",6,5.57,1291.79,,0.003,0.001,506.536,0.059,0.037,0.0095,8524.542,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-11-30",10,9.22,1737.6,,0.004,0.001,720.509,0.0591,0.16,0.0418,12125.777,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-03",4,3.35,527.3,,0.001,0.001,231.52,0.059,0.078,0.0598,3895.995,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-18",16,15.19,3126.99,,0.006,0.001,1287.107,0.0591,0.249,0.0354,21659.034,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-19",18,17.54,3964.93,,0.008,0.001,1587.758,0.059,0.16,0.0165,26724.074,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-20",8,7.98,1748.54,,0.004,0.001,695.498,0.059,0.046,0.0079,11702.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-29",11,10.48,2326.92,,0.005,0.001,933.412,0.059,0.134,0.0285,15705.812,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-30",21,19.76,4077.13,,0.008,0.001,1646.513,0.059,0.153,0.0138,27707.619,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Calpine Sutter Energy Center",55112,"CT02",,"2020-12-31",11,10.47,2508.63,,0.005,0.001,1021.865,0.0591,0.127,0.0239,17194.579,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-02",11,11,2171,,0.005,0.001,956,0.059,0.094,0.0186,16085.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-03",24,24,5642,,0.012,0.001,2346.8,0.059,0.158,0.008,39485.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-04",1,0.67,89.78,,0,0.001,45.091,0.059,0.004,0.01,758.641,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-06",12,10.39,1632.96,,0.004,0.001,779.415,0.0591,0.113,0.0318,13114.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-07",24,24,5183,,0.011,0.001,2173.1,0.059,0.141,0.0077,36560.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-08",1,0.52,56.16,,0,0.001,31.408,0.059,0.003,0.011,528.268,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-18",22,21.68,4304.44,,0.009,0.001,1863.072,0.059,0.142,0.015,31349.028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-19",20,19.25,4028.66,,0.009,0.001,1741.06,0.059,0.12,0.0089,29290.153,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-20",1,0.63,70.56,,0,0.001,38.115,0.059,0.004,0.012,640.899,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-04",11,10.75,2138.25,,0.005,0.001,937.925,0.059,0.107,0.0292,15780.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-05",18,17.47,4043.61,,0.009,0.001,1705.103,0.059,0.124,0.0114,28695.024,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-06",1,0.4,51.6,,0,0.001,26.24,0.059,0.002,0.007,441.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-08",16,14.82,1934.11,,0.005,0.001,932.628,0.059,0.104,0.0215,15691.515,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-09",24,24,5866,,0.012,0.001,2438.2,0.059,0.144,0.007,41026.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-10",24,24,5522,,0.012,0.001,2309.5,0.059,0.135,0.007,38864.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-11",24,24,5758,,0.012,0.001,2396.5,0.059,0.141,0.007,40319.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-12",17,15.96,3155.78,,0.007,0.001,1359.301,0.059,0.091,0.0114,22872.339,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-13",24,24,5877,,0.012,0.001,2441,0.059,0.142,0.0069,41072.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-14",24,24,5759,,0.012,0.001,2392.3,0.059,0.141,0.007,40254,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-15",20,19.46,4342.28,,0.009,0.001,1834.256,0.059,0.123,0.0103,30861.942,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-16",24,24,6011,,0.013,0.001,2482.4,0.059,0.146,0.007,41765.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-17",24,24,5652,,0.012,0.001,2352.2,0.059,0.139,0.007,39575.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-18",24,24,5812,,0.012,0.001,2407.5,0.059,0.142,0.007,40508.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-19",24,24,5906,,0.012,0.001,2441.6,0.059,0.145,0.007,41082.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-20",24,24,5354,,0.011,0.001,2240.4,0.059,0.131,0.0069,37698.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-21",9,8.77,1863.92,,0.004,0.001,788.887,0.059,0.047,0.0073,13271.664,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-08",23,22.73,5029.03,,0.011,0.001,2144.96,0.059,0.162,0.0147,36087.194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-09",24,24,6047,,0.013,0.001,2506.8,0.059,0.148,0.007,42180,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-10",24,23.57,5188.71,,0.011,0.001,2197.135,0.059,0.131,0.0071,36971.195,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-13",7,6.78,771.02,,0.002,0.001,392.334,0.059,0.07,0.0394,6602.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-14",8,7.35,1665.35,,0.004,0.001,703.85,0.059,0.042,0.0075,11845.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-26",11,10,1692.54,,0.004,0.001,772.745,0.0591,0.096,0.0415,13001.879,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-28",10,9.23,1946.92,,0.004,0.001,850.917,0.059,0.079,0.0372,14318.239,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-29",11,8.84,1026.4,,0.003,0.001,511.471,0.059,0.045,0.0191,8605.983,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-02",14,13.68,2659.76,,0.006,0.001,1169.224,0.059,0.095,0.0183,19679.412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-03",24,24,5965,,0.013,0.001,2492.4,0.059,0.147,0.007,41942.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-04",24,23.75,5716.75,,0.012,0.001,2391.775,0.059,0.141,0.007,40244.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-10",13,12.18,2431.67,,0.005,0.001,1081.455,0.0591,0.123,0.0477,18195.913,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-11",10,8.95,1765.67,,0.004,0.001,787.348,0.059,0.065,0.0181,13247.656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-24",10,8.62,947.84,,0.002,0.001,483.346,0.059,0.075,0.0488,8130.957,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-25",9,8.17,1253.75,,0.003,0.001,585.241,0.059,0.044,0.0127,9850.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-10",14,13.39,2665.53,,0.006,0.001,1180.547,0.059,0.102,0.0211,19863.977,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-11",11,10.69,2246.56,,0.005,0.001,984.071,0.059,0.07,0.0105,16559.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-12",12,11.7,2380,,0.005,0.001,1079.955,0.059,0.079,0.0113,18174.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-13",10,9.5,1926.65,,0.004,0.001,849.844,0.059,0.068,0.0138,14299.834,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-14",10,9.75,1973.4,,0.004,0.001,867.82,0.059,0.069,0.0135,14603.065,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-16",9,8.38,1127.42,,0.003,0.001,540.13,0.059,0.054,0.0283,9087.768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-17",9,8.42,1345.82,,0.003,0.001,619.432,0.059,0.052,0.0127,10422.684,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-18",2,0.67,26.8,,0,0.001,22.318,0.059,0.002,0.005,375.759,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-22",1,0.23,0,,0,0.001,6.072,0.059,0.026,0.509,102.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-27",15,13.7,2699.6,,0.006,0.001,1204.152,0.059,0.103,0.0244,20261.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-28",13,12.03,2548.79,,0.006,0.001,1120.785,0.059,0.083,0.0192,18861.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-29",14,13.4,2881.5,,0.006,0.001,1257.42,0.059,0.087,0.0113,21157.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-30",14,13.86,2937.46,,0.006,0.001,1280.868,0.059,0.089,0.0103,21551.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-07-31",14,13.37,2819.63,,0.006,0.001,1229.628,0.059,0.086,0.0112,20690.954,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-01",13,12.5,2553.5,,0.006,0.001,1119.8,0.059,0.085,0.016,18843.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-02",14,12.46,1850.9,,0.004,0.001,867.984,0.059,0.066,0.0126,14604.834,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-03",11,10.98,2426.24,,0.006,0.001,1091.25,0.059,0.085,0.0125,18363.406,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-04",5,4.33,639.35,,0.002,0.001,320.361,0.059,0.043,0.0314,5390.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-05",6,5.43,838.96,,0.002,0.001,380.842,0.059,0.023,0.0078,6410.188,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-12",11,10.13,1516.09,,0.004,0.001,719.074,0.059,0.069,0.0206,12097.897,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-13",15,14.47,3324.87,,0.007,0.001,1448.195,0.059,0.098,0.0131,24368.401,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-14",24,24,5081,,0.011,0.001,2180.2,0.059,0.123,0.0066,36686.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-15",24,24,5072,,0.011,0.001,2172.3,0.059,0.111,0.0058,36553.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-16",24,24,4194,,0.009,0.001,1837.4,0.059,0.076,0.0045,30925.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-17",24,24,4521,,0.01,0.001,1967.8,0.059,0.086,0.0048,33113.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-18",24,24,4380,,0.01,0.001,1920.1,0.059,0.089,0.0051,32308.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-19",24,23.52,4222.16,,0.009,0.001,1853.476,0.059,0.085,0.0053,31193.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-20",14,13.22,1661.94,,0.004,0.001,790.57,0.059,0.046,0.0102,13305.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-21",15,14.45,2052.55,,0.005,0.001,935.67,0.059,0.055,0.0116,15741.235,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-22",23,22.55,3879.45,,0.009,0.001,1716.115,0.059,0.081,0.0054,28878.175,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-23",11,10.4,2025,,0.005,0.001,897.46,0.059,0.066,0.0186,15102.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-24",24,23.52,4154.08,,0.009,0.001,1822.004,0.059,0.077,0.005,30661.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-25",12,10.87,1428.18,,0.003,0.001,685.53,0.059,0.039,0.0154,11535.836,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-26",12,9.75,1155.22,,0.003,0.001,582.742,0.059,0.04,0.0153,9803.007,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-27",15,14.78,2327.42,,0.005,0.001,1053.138,0.059,0.07,0.0101,17720.084,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-28",24,23.8,5140.6,,0.011,0.001,2199.22,0.059,0.124,0.0066,37004.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-03",10,9.92,1580.28,,0.004,0.001,721.852,0.059,0.064,0.0178,12146.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-04",18,17.04,2772.12,,0.006,0.001,1251.417,0.059,0.085,0.009,21055.142,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-05",19,17.59,2428.59,,0.006,0.001,1122.435,0.059,0.079,0.0175,18888.034,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-06",17,16.37,2862.9,,0.006,0.001,1283.662,0.059,0.083,0.0086,21599.206,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-07",14,13.08,2351.13,,0.005,0.001,1055.293,0.059,0.062,0.0138,17757.859,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-08",14,12.9,2223.74,,0.005,0.001,1008.964,0.059,0.075,0.015,16979.166,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-09",13,12.5,2067,,0.005,0.001,926.95,0.059,0.073,0.0162,15597.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-10",23,22.82,5490.08,,0.012,0.001,2299.506,0.059,0.135,0.007,38692.616,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-14",15,14.52,2940.68,,0.007,0.001,1288.744,0.059,0.104,0.0199,21688.292,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-15",24,24,5153,,0.011,0.001,2191.7,0.059,0.115,0.0061,36881.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-16",24,24,5491,,0.012,0.001,2324.5,0.059,0.131,0.0066,39116.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-17",24,24,5470,,0.012,0.001,2317.2,0.059,0.131,0.0066,38992.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-18",24,23.98,5411.86,,0.012,0.001,2297.994,0.059,0.133,0.0068,38671.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-21",12,11.47,2144.35,,0.005,0.001,956.224,0.059,0.079,0.0228,16091.358,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-22",24,24,5085,,0.011,0.001,2167.3,0.059,0.124,0.0068,36466.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-23",24,22.42,3866.7,,0.009,0.001,1786.817,0.059,0.132,0.0192,30070.351,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-24",23,22.75,4713.75,,0.01,0.001,2014.9,0.059,0.117,0.0069,33909.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-26",12,11.52,2234.68,,0.005,0.001,978.344,0.059,0.082,0.0207,16462.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-27",18,16.35,3016.48,,0.007,0.001,1319.524,0.059,0.091,0.0154,22202.155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-28",24,24,5321,,0.011,0.001,2242.9,0.059,0.132,0.007,37741.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-29",24,24,5765,,0.012,0.001,2406.3,0.059,0.142,0.007,40493.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-09-30",24,24,5349,,0.011,0.001,2244.5,0.059,0.132,0.007,37774.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-01",24,24,5993,,0.013,0.001,2485.6,0.059,0.146,0.007,41820.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-02",24,24,5929,,0.012,0.001,2454.2,0.059,0.144,0.007,41295.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-03",24,24,5985,,0.012,0.001,2468,0.059,0.146,0.007,41526.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-04",24,24,5573,,0.012,0.001,2314.5,0.059,0.136,0.007,38944.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-05",24,24,6049,,0.013,0.001,2504.2,0.059,0.147,0.007,42137.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-06",24,24,5401,,0.011,0.001,2267.6,0.059,0.133,0.007,38156.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-07",23,22.92,4595.2,,0.01,0.001,1953.24,0.059,0.1,0.0062,32865.876,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-10",11,10.18,2006.54,,0.005,0.001,892.758,0.059,0.083,0.0459,15024.548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-11",11,10.53,2164.66,,0.005,0.001,950.747,0.059,0.073,0.0163,15998.336,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-12",24,24,5041,,0.011,0.001,2154,0.059,0.12,0.0065,36243.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-13",24,24,5879,,0.012,0.001,2474.4,0.059,0.147,0.0071,41631.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-14",24,24,5907,,0.013,0.001,2486.3,0.059,0.146,0.007,41836.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-15",24,24,6015,,0.013,0.001,2522.8,0.059,0.149,0.007,42450.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-16",24,24,5908,,0.012,0.001,2471.5,0.059,0.145,0.007,41588.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-17",24,24,5676,,0.012,0.001,2386,0.059,0.137,0.0068,40153.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-18",18,17.39,3877.85,,0.008,0.001,1659.967,0.059,0.107,0.0102,27933.783,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-19",24,24,5866,,0.012,0.001,2460.6,0.059,0.145,0.007,41406.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-20",24,24,5924,,0.013,0.001,2483.6,0.059,0.146,0.007,41788.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-21",24,24,5899,,0.012,0.001,2462.8,0.059,0.144,0.007,41441.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-22",9,8.22,1379.19,,0.003,0.001,630.497,0.059,0.055,0.0156,10609.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-23",24,24,5935,,0.013,0.001,2487.1,0.059,0.152,0.0073,41851.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-24",24,23.47,5520.6,,0.012,0.001,2330.417,0.059,0.153,0.0078,39206.559,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-26",12,11.68,2337.8,,0.005,0.001,1021.128,0.059,0.097,0.0205,17180.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-27",24,24,5739,,0.012,0.001,2391.8,0.059,0.16,0.0079,40241.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-28",24,24,5708,,0.012,0.001,2388.5,0.059,0.145,0.0072,40191,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-29",23,22.68,5309.32,,0.011,0.001,2225.312,0.059,0.13,0.007,37444.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-02",13,11.48,2214.56,,0.005,0.001,987.252,0.059,0.097,0.0382,16609.678,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-03",12,11.6,2590.2,,0.006,0.001,1103.86,0.059,0.083,0.0152,18574.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-04",24,24,4312,,0.009,0.001,1867.7,0.059,0.085,0.005,31420.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-05",24,24,4926,,0.011,0.001,2087.3,0.059,0.103,0.0055,35125.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-06",24,23.42,5343.82,,0.011,0.001,2232.438,0.059,0.125,0.0066,37565.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-09",8,7.32,1095.56,,0.003,0.001,518.148,0.0591,0.061,0.0448,8719.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-10",2,1.73,310.6,,0.001,0.001,139.249,0.059,0.009,0.0075,2343.706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-11",10,9.15,1095.45,,0.003,0.001,536.2,0.059,0.046,0.05,9025.365,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-12",12,11.07,1948.62,,0.004,0.001,872.767,0.059,0.066,0.0138,14684.692,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-13",2,1.4,165.8,,0,0.001,82.68,0.059,0.005,0.008,1390.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-14",21,19.37,2704.17,,0.006,0.001,1270.996,0.059,0.097,0.0124,21391.329,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-15",10,9.82,1824.52,,0.004,0.001,805.384,0.059,0.058,0.0122,13551.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-16",23,22.43,3845.53,,0.009,0.001,1687.883,0.059,0.078,0.0054,28403.17,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-17",11,10.1,1998.44,,0.004,0.001,873.984,0.059,0.068,0.0142,14708.366,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-19",12,11.28,2104.68,,0.005,0.001,930.232,0.059,0.083,0.0303,15654.156,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-20",24,23.6,4697.4,,0.01,0.001,2005.36,0.059,0.117,0.007,33741.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-04",12,11.33,2156.33,,0.005,0.001,952.913,0.059,0.097,0.0442,16036.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-05",1,0.42,32.76,,0,0.001,20.706,0.059,0.002,0.012,348.306,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-07",10,9.2,1659.96,,0.004,0.001,748.104,0.059,0.079,0.03,12588.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-08",11,10.78,2204.2,,0.005,0.001,948.728,0.059,0.078,0.0143,15964.638,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-09",24,24,4347,,0.009,0.001,1870.3,0.059,0.097,0.0059,31473.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-10",3,2.42,309.08,,0.001,0.001,145.406,0.059,0.008,0.007,2445.906,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-15",11,10.78,1992.24,,0.004,0.001,890.19,0.059,0.086,0.0218,14981.742,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-16",24,24,4900,,0.011,0.001,2093.5,0.059,0.106,0.0056,35228.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-17",3,2.42,305.82,,0.001,0.001,145.954,0.059,0.005,0.0047,2455.958,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-18",11,10.95,2136,,0.005,0.001,939.26,0.059,0.077,0.0151,15805.985,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-19",11,9.52,1686.32,,0.004,0.001,754.294,0.059,0.062,0.0475,12694.978,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-20",14,12.75,2348.45,,0.005,0.001,1036.86,0.059,0.071,0.018,17445.485,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-21",12,10.92,1864,,0.004,0.001,837.496,0.059,0.06,0.0151,14093.648,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-22",15,13.52,2296.55,,0.005,0.001,1033.904,0.0591,0.069,0.0201,17393.811,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-23",24,24,4571,,0.01,0.001,1996.5,0.059,0.115,0.0068,33597.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-24",2,1.45,171.75,,0,0.001,85.745,0.059,0.006,0.0095,1442.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-02",11,10.55,2119.05,,0.005,0.001,916.62,0.059,0.099,0.0288,15425.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-03",24,24,5569,,0.012,0.001,2288.9,0.059,0.154,0.008,38512.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-04",1,0.65,85.15,,0,0.001,42.315,0.059,0.003,0.009,711.815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-06",11,10.73,2143.49,,0.005,0.001,930.925,0.059,0.096,0.0229,15665.175,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-07",24,24,5224,,0.011,0.001,2164.8,0.059,0.145,0.0079,36428.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-08",1,0.57,60.42,,0,0.001,32.376,0.059,0.002,0.009,544.521,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-19",11,10.37,2041.7,,0.004,0.001,884.766,0.059,0.097,0.0374,14888.998,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-20",20,18.97,4054.56,,0.009,0.001,1694.649,0.059,0.124,0.0108,28512.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-21",1,0.63,78.75,,0,0.001,39.501,0.059,0.003,0.009,664.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-09",23,22.53,4631.36,,0.01,0.001,1958.684,0.059,0.169,0.0184,32956.831,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-10",24,24,5648,,0.012,0.001,2315.8,0.059,0.156,0.008,38970.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-11",24,24,5753,,0.012,0.001,2351.1,0.059,0.158,0.008,39567.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-12",24,24,5820,,0.012,0.001,2376.1,0.059,0.16,0.008,39981.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-13",24,24,5993,,0.012,0.001,2446.7,0.059,0.165,0.008,41171.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-14",24,24,5746,,0.012,0.001,2347.2,0.059,0.158,0.008,39504.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-15",20,18.87,4240.3,,0.009,0.001,1753.23,0.059,0.13,0.0149,29504.145,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-16",24,24,5974,,0.012,0.001,2423.6,0.059,0.163,0.008,40781.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-17",24,24,5601,,0.012,0.001,2281.2,0.059,0.154,0.008,38381.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-18",24,24,5765,,0.012,0.001,2334.6,0.059,0.157,0.008,39279.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-19",24,24,5859,,0.012,0.001,2372.7,0.059,0.16,0.008,39918.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-20",24,24,4869,,0.01,0.001,2012.3,0.059,0.133,0.0078,33857.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-21",5,4.48,1049.04,,0.002,0.001,430.38,0.059,0.029,0.0084,7241.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-13",7,6.42,697.2,,0.002,0.001,351.782,0.059,0.057,0.0463,5916.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-14",14,12.95,2435.93,,0.005,0.001,1040.63,0.059,0.089,0.0239,17508.687,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-15",7,6.42,1512.34,,0.003,0.001,619.754,0.059,0.042,0.0086,10427.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-26",12,9.6,1745.16,,0.004,0.001,792.474,0.0591,0.1,0.0729,13334.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-27",13,12.42,2534.56,,0.006,0.001,1099.592,0.059,0.09,0.017,18503.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-28",9,7.6,1485.35,,0.003,0.001,661.622,0.059,0.064,0.0163,11131.653,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-29",10,8.48,951.08,,0.002,0.001,469.272,0.059,0.052,0.0447,7897.913,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-02",14,12.42,2362.15,,0.005,0.001,1052.052,0.059,0.105,0.0278,17703.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-03",22,21.62,5110.16,,0.011,0.001,2156.624,0.059,0.168,0.0141,36294.102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-04",24,23.48,5446.56,,0.012,0.001,2278.2,0.059,0.143,0.0072,38337.752,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-10",15,14.1,2686,,0.006,0.001,1205.072,0.059,0.113,0.0235,20275.542,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-24",9,8.3,866.15,,0.002,0.001,444.66,0.059,0.052,0.021,7483.795,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-25",9,7.8,1193.07,,0.003,0.001,553.926,0.059,0.046,0.0179,9319.941,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-10",9,8.97,1342.7,,0.003,0.001,624.782,0.059,0.071,0.023,10514.829,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-11",9,7.45,1208.65,,0.003,0.001,562.8,0.059,0.049,0.0523,9470.025,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-12",12,10.68,2143.56,,0.005,0.001,935.45,0.059,0.073,0.013,15740.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-13",8,7.43,929.16,,0.002,0.001,444.59,0.0591,0.04,0.0258,7478.635,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-14",10,8.42,1296.17,,0.003,0.001,596.207,0.059,0.049,0.0134,10034.218,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-15",10,9.15,1174.05,,0.003,0.001,551.855,0.059,0.04,0.0136,9284.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-16",8,7.62,1043.64,,0.002,0.001,485.608,0.059,0.04,0.0168,8172.134,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-17",9,7.85,1078.48,,0.003,0.001,511.918,0.0591,0.042,0.021,8613.777,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-18",1,0.38,25.84,,0,0.001,17.936,0.059,0.001,0.004,301.758,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-19",10,8.61,973.53,,0.002,0.001,477.386,0.059,0.048,0.0354,8037.076,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-20",9,7.92,1240.6,,0.003,0.001,561,0.059,0.045,0.0167,9441.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-21",9,8.33,1191.15,,0.003,0.001,543.94,0.059,0.046,0.0121,9152.236,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-27",12,11.48,2214.32,,0.005,0.001,971.689,0.059,0.096,0.0263,16348.093,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-28",12,10.9,2289.71,,0.005,0.001,960.412,0.059,0.078,0.0204,16159.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-29",13,12.31,2611.33,,0.006,0.001,1114.786,0.059,0.079,0.0096,18759.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-30",14,13.05,2794.45,,0.006,0.001,1183.857,0.059,0.089,0.0129,19921.853,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-07-31",14,12.78,2707.64,,0.006,0.001,1124.486,0.059,0.085,0.0178,18921.444,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-01",11,10.55,2100.75,,0.005,0.001,920.86,0.059,0.073,0.0115,15495.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-02",9,7.75,1291.19,,0.003,0.001,542.416,0.059,0.049,0.026,9125.983,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-03",15,14.03,1780.56,,0.004,0.001,760.4,0.059,0.056,0.011,12795.277,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-10",15,14.57,3052.27,,0.007,0.001,1300.425,0.0591,0.112,0.0213,21880.932,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-11",13,11.65,2401.72,,0.005,0.001,1027.557,0.059,0.081,0.0146,17289.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-12",9,8,1308.79,,0.003,0.001,667.81,0.059,0.071,0.0242,11238.552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-13",17,16.5,3736,,0.008,0.001,1596.2,0.059,0.115,0.0114,26860.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-14",24,24,4589,,0.01,0.001,1967.9,0.059,0.129,0.0078,33119.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-15",24,24,4903,,0.011,0.001,2079.9,0.059,0.14,0.008,35000.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-16",24,24,3908,,0.009,0.001,1701.7,0.059,0.115,0.008,28640.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-17",24,24,4348,,0.009,0.001,1876.1,0.059,0.126,0.008,31571.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-18",24,24,4091,,0.009,0.001,1779.9,0.059,0.12,0.008,29944.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-19",24,23.45,4056.2,,0.009,0.001,1765.485,0.059,0.119,0.0081,29708.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-20",14,12.58,1481.16,,0.003,0.001,685.7,0.059,0.06,0.0248,11537.504,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-21",14,13.13,1566.16,,0.003,0.001,680.17,0.0591,0.056,0.0121,11442.667,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-22",9,7.47,1241.34,,0.003,0.001,550.248,0.059,0.052,0.0502,9257.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-23",10,8.95,1405.3,,0.004,0.001,705.9,0.059,0.072,0.0231,11878.705,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-24",17,15.9,2213.85,,0.006,0.001,1154.221,0.059,0.071,0.0108,19417.537,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-25",11,10.97,1490.92,,0.004,0.001,734.835,0.059,0.053,0.01,12364.047,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-26",13,11.27,1306.61,,0.003,0.001,671.466,0.059,0.047,0.0161,11297.613,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-27",13,11.98,1520.44,,0.004,0.001,704.38,0.059,0.07,0.0192,11850.488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-28",9,7.88,1110.24,,0.003,0.001,497.796,0.059,0.054,0.027,8374.764,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-29",8,7.05,819,,0.002,0.001,325,0.0591,0.043,0.0501,5469.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-30",2,1.45,157.85,,0,0.001,62.935,0.059,0.004,0.0085,1059.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-03",14,12.85,2468.93,,0.005,0.001,1024.345,0.059,0.1,0.0276,17234.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-04",14,13.35,2461.08,,0.005,0.001,1001.866,0.059,0.078,0.0114,16858.583,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-05",18,17.78,2363.88,,0.005,0.001,1035.742,0.059,0.046,0.0062,17428.156,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-06",17,15.41,2582.89,,0.007,0.001,1324.623,0.059,0.106,0.0158,22286.834,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-07",16,15.73,2583.87,,0.006,0.001,1211.654,0.059,0.091,0.0097,20384.907,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-08",10,8.92,1734.52,,0.004,0.001,751.434,0.059,0.075,0.0337,12644.076,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-09",13,12.22,1917.2,,0.005,0.001,909.54,0.059,0.084,0.0285,15302.938,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-10",23,22.52,5504.48,,0.012,0.001,2426.716,0.059,0.164,0.008,40832.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-13",13,12.55,2567.5,,0.005,0.001,1036.195,0.059,0.108,0.0245,17435.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-14",24,24,5200,,0.012,0.001,2306.6,0.059,0.15,0.0075,38811.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-15",24,24,5148,,0.012,0.001,2315.4,0.059,0.144,0.0073,38962.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-16",24,24,5533,,0.011,0.001,2152.3,0.059,0.143,0.0078,36216.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-17",23,22.67,5050.31,,0.01,0.001,1984.577,0.059,0.133,0.008,33391.409,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-26",11,10.07,1948,,0.004,0.001,810.37,0.0592,0.089,0.0411,13638.103,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-27",16,14.87,2513.49,,0.006,0.001,1150.862,0.059,0.11,0.0219,19362.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-28",24,24,5269,,0.012,0.001,2466,0.059,0.166,0.008,41499.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-29",24,24,5790,,0.015,0.001,2896.3,0.059,0.181,0.0075,48736.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-09-30",24,24,5250,,0.012,0.001,2371.6,0.059,0.157,0.0079,39908.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-01",24,24,5639,,0.012,0.001,2465.1,0.059,0.146,0.007,41477.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-02",24,24,5511,,0.012,0.001,2399.5,0.059,0.159,0.0079,40374.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-03",24,24,5919,,0.013,0.001,2571.3,0.059,0.174,0.008,43266,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-04",24,24,5455,,0.012,0.001,2385.9,0.059,0.158,0.0078,40146.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-05",24,24,5611,,0.012,0.001,2444.3,0.059,0.159,0.0077,41126.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-06",24,24,4794,,0.011,0.001,2120.7,0.059,0.129,0.0071,35682.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-07",11,9.5,1851.89,,0.004,0.001,866.787,0.059,0.078,0.0174,14583.458,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-10",10,9.85,1752.2,,0.004,0.001,824.93,0.059,0.092,0.0229,13880.955,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-11",11,9.93,1990.1,,0.005,0.001,916.212,0.0591,0.082,0.0146,15417.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-12",24,24,4760,,0.011,0.001,2131.8,0.059,0.129,0.0069,35871.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-13",24,24,5601,,0.012,0.001,2472.7,0.059,0.166,0.008,41608.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-14",24,24,5297,,0.012,0.001,2344.8,0.059,0.158,0.008,39454.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-15",24,24,4670,,0.011,0.001,2083.6,0.059,0.14,0.008,35062.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-16",24,24,5569,,0.013,0.001,2638.7,0.059,0.178,0.008,44407.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-17",24,24,5569,,0.014,0.001,2856.8,0.059,0.177,0.007,48073,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-18",11,10.35,2153.35,,0.006,0.001,1141.925,0.059,0.099,0.0175,19214.791,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-19",24,24,5967,,0.015,0.001,2987.1,0.059,0.201,0.008,50265.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-20",24,24,5970,,0.013,0.001,2498.3,0.059,0.166,0.0079,42038.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-21",24,24,5912,,0.011,0.001,2267.8,0.059,0.152,0.008,38158.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-22",9,7.9,1291.3,,0.004,0.001,699.49,0.059,0.069,0.0248,11769.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-23",24,24,5969,,0.015,0.001,2967.1,0.059,0.2,0.008,49927.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-24",23,22.57,5338.84,,0.013,0.001,2655.843,0.059,0.178,0.008,44693.133,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-26",12,11.27,2240.97,,0.005,0.001,977.391,0.059,0.102,0.0371,16444.843,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-27",24,24,5659,,0.012,0.001,2347.4,0.059,0.156,0.0079,39501.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-28",24,24,5703,,0.012,0.001,2370,0.059,0.157,0.0078,39876.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-29",22,21.55,5033.95,,0.011,0.001,2095.465,0.059,0.137,0.0077,35259.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-02",13,11.92,2289.2,,0.005,0.001,997.572,0.059,0.104,0.0324,16784.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-03",11,10.62,2332.5,,0.005,0.001,994.174,0.059,0.087,0.0179,16727.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-04",24,24,4142,,0.009,0.001,1787.2,0.059,0.079,0.0045,30073.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-05",24,24,4793,,0.01,0.001,2032.1,0.059,0.114,0.0061,34197.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-06",23,22.52,5133.48,,0.011,0.001,2127.692,0.059,0.138,0.0077,35800.516,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-09",9,8.65,1338.8,,0.003,0.001,616.255,0.059,0.077,0.0313,10370.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-10",1,0.37,24.42,,0,0.001,17.538,0.059,0.001,0.006,295.038,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-11",9,8.7,964.4,,0.002,0.001,424.48,0.059,0.051,0.0256,7141.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-12",12,11.07,1810.62,,0.004,0.001,834.379,0.059,0.079,0.016,14038.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-13",4,3.26,309.4,,0.001,0.001,167.888,0.059,0.034,0.0265,2825.632,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-14",23,21.93,3063.16,,0.007,0.001,1388.781,0.059,0.103,0.0109,23370.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-15",12,10.95,1901.57,,0.004,0.001,848.32,0.059,0.077,0.0168,14272.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-16",24,23.38,3806.46,,0.008,0.001,1628.898,0.059,0.079,0.0054,27410.026,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-19",12,11.87,2147.44,,0.005,0.001,949.249,0.059,0.097,0.0207,15973.97,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-20",24,24,4770,,0.01,0.001,2017.4,0.059,0.118,0.0065,33946,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-21",2,1.4,171.6,,0,0.001,82.6,0.059,0.005,0.008,1389.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-08",12,11.73,2172.3,,0.005,0.001,951.795,0.059,0.107,0.0259,16014.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-09",24,24,4006,,0.009,0.001,1727.4,0.059,0.09,0.0058,29069.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-10",1,0.75,96.75,,0,0.001,47.175,0.059,0.002,0.006,793.575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-11",11,10.68,2105.84,,0.005,0.001,919.376,0.059,0.094,0.0237,15469.544,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-12",1,0.43,38.27,,0,0.001,23.091,0.059,0.002,0.011,388.677,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-13",11,10.4,1790.4,,0.004,0.001,791,0.059,0.082,0.0315,13311.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-14",24,24,3335,,0.007,0.001,1483,0.059,0.084,0.0067,24959.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-15",21,20.02,3593.66,,0.008,0.001,1556.588,0.059,0.116,0.0106,26189.792,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-16",12,10.67,2178.08,,0.005,0.001,931.828,0.059,0.076,0.0251,15679.359,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-17",19,18.42,3464,,0.008,0.001,1488.498,0.059,0.103,0.0113,25046.542,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-18",24,24,4085,,0.009,0.001,1739.1,0.059,0.077,0.0046,29264.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-19",12,10.97,1838.08,,0.004,0.001,810.45,0.059,0.064,0.0173,13637.733,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-20",13,12.25,2176.15,,0.005,0.001,950.22,0.059,0.068,0.0109,15989.135,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-21",24,24,3783,,0.008,0.001,1653.2,0.059,0.068,0.0046,27818.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-22",18,17.27,2863.91,,0.006,0.001,1240.28,0.059,0.084,0.0138,20872.921,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-23",24,24,4551,,0.009,0.001,1737.2,0.059,0.105,0.0072,29234,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-24",2,1.43,165.82,,0,0.001,69.903,0.059,0.005,0.009,1175.654,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-29",11,10.25,1802.5,,0.004,0.001,771.75,0.059,0.099,0.0294,12988.975,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-30",1,0.42,31.08,,0,0.001,20.748,0.059,0.002,0.009,349.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-10",16,15.05,2944,,0.007,0.001,1287.805,0.059,0.072,0.0095,21666.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-11",21,19.39,2801.97,,0.007,0.001,1437.188,0.059,0.06,0.0074,24182.462,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-20",12,11.57,2422.13,,0.005,0.001,1026.842,0.059,0.075,0.0188,17276.193,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-21",2,1.02,124.04,,0,0.001,59.084,0.059,0.001,0.0085,993.654,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-22",11,10.28,2127.8,,0.005,0.001,898.636,0.0591,0.041,0.0181,15120.804,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-23",2,1.03,118.09,,0,0.001,57.26,0.059,0.001,0.007,964.015,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-06",13,12.5,2532.5,,0.005,0.001,1080.3,0.059,0.08,0.0162,18178.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-07",10,9.25,2114,,0.004,0.001,875.9,0.059,0.047,0.0063,14738.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-10",23,22.83,4795.13,,0.01,0.001,2008.515,0.059,0.105,0.0084,33798.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-11",24,22.93,5151.37,,0.011,0.001,2121.555,0.059,0.105,0.0082,35699.561,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-12",9,8.63,2090.94,,0.004,0.001,849.654,0.059,0.045,0.0061,14298.851,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-13",20,19.48,3200.28,,0.007,0.001,1384.952,0.059,0.054,0.0086,23303.876,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-14",24,24,5720,,0.012,0.001,2333.7,0.059,0.118,0.0058,39265.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-15",19,18.21,4157.64,,0.009,0.001,1716.211,0.059,0.092,0.0075,28884.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-16",24,24,5999,,0.012,0.001,2429.5,0.059,0.108,0.0053,40879.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-17",24,24,5411,,0.011,0.001,2212.8,0.059,0.09,0.0047,37234.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-18",24,24,5428,,0.011,0.001,2215.4,0.059,0.088,0.0046,37278.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-19",8,7.37,1747.97,,0.004,0.001,713.163,0.059,0.029,0.0048,11999.215,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-26",11,9.83,1819.91,,0.004,0.001,796.411,0.0592,0.032,0.0159,13400.403,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-27",12,11.42,2340.58,,0.005,0.001,996.916,0.0591,0.03,0.0052,16776.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-28",10,9.29,1676.97,,0.004,0.001,732.006,0.059,0.034,0.008,12318.363,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-02",13,12.72,2243.92,,0.005,0.001,998.192,0.059,0.06,0.0115,16799.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-03",24,24,5836,,0.012,0.001,2442.4,0.059,0.11,0.0053,41100,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-04",24,23.45,5052.1,,0.011,0.001,2133.055,0.059,0.055,0.0029,35891.925,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-10",14,13.48,2517.84,,0.006,0.001,1103.548,0.0591,0.068,0.0142,18568.556,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-11",8,6.35,473.95,,0.001,0.001,264.607,0.059,0.006,0.0044,4454.598,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-07",10,8.51,672.44,,0.002,0.001,374.261,0.059,0.04,0.0343,6296.655,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-08",10,8.72,1229.78,,0.003,0.001,571.706,0.059,0.031,0.0067,9621.764,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-09",8,7.48,1161.24,,0.003,0.001,526.52,0.0591,0.025,0.011,8860.912,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-10",9,7.84,1047.12,,0.002,0.001,493.452,0.059,0.021,0.0084,8306.128,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-11",9,7.95,1188.65,,0.003,0.001,544.74,0.0591,0.019,0.0068,9163.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-12",11,9.85,1348.75,,0.003,0.001,621.68,0.059,0.021,0.0071,10463.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-13",10,8.15,795.39,,0.002,0.001,409.678,0.059,0.017,0.0074,6893.045,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-14",13,11.65,1092.41,,0.003,0.001,557.905,0.059,0.017,0.0075,9390.132,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-15",11,10.35,1069.55,,0.003,0.001,532.295,0.059,0.023,0.0055,8958.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-18",2,0.88,8.12,,0,0.001,26.034,0.059,0.02,0.0645,438.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-19",13,10.97,745.04,,0.002,0.001,444.313,0.0591,0.027,0.0157,7474.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-20",9,7.79,1000.15,,0.002,0.001,474.722,0.059,0.027,0.0132,7986.197,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-21",9,7.97,722.75,,0.002,0.001,377.474,0.059,0.02,0.0089,6353.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-23",10,9.22,1085.87,,0.003,0.001,529.83,0.059,0.035,0.0145,8918.579,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-27",11,10.11,1678.48,,0.004,0.001,760.352,0.0591,0.046,0.0165,12795.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-28",9,8.1,1580.74,,0.003,0.001,686.917,0.059,0.037,0.0143,11555.707,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-29",22,21.43,3550.03,,0.008,0.001,1573.895,0.059,0.077,0.0076,26481.434,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-30",22,21.7,2355.3,,0.006,0.001,1131,0.059,0.023,0.002,19027.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-07-31",16,15.72,2275.04,,0.005,0.001,1039.672,0.059,0.052,0.007,17494.588,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-01",15,13.11,2212.47,,0.005,0.001,983.002,0.059,0.041,0.0097,16541.155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-02",15,13.77,1321.03,,0.003,0.001,669.133,0.0591,0.021,0.0068,11258.492,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-03",16,14.95,1293.39,,0.003,0.001,674.45,0.0591,0.017,0.0041,11346.899,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-04",9,7.95,1361.67,,0.003,0.001,608.514,0.059,0.036,0.0116,10241.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-09",10,8.75,979,,0.002,0.001,485.95,0.0591,0.033,0.0291,8175.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-10",9,8.35,1069.9,,0.003,0.001,504.53,0.059,0.016,0.0052,8489.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-11",10,9.03,1182.1,,0.003,0.001,551.83,0.059,0.02,0.0078,9287.308,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-12",13,12.33,2762.96,,0.006,0.001,1165.529,0.059,0.075,0.0153,19610.277,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-13",24,24,5875,,0.012,0.001,2424.1,0.059,0.047,0.0023,40785.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-14",24,24,4598,,0.01,0.001,1984.9,0.0593,0.085,0.0042,33397,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-15",24,24,5589,,0.012,0.001,2308.4,0.059,0.07,0.0036,38837.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-16",24,24,2171,,0.006,0.001,1098.8,0.059,0.023,0.0024,18490.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-17",24,24,3056,,0.007,0.001,1420.6,0.0593,0.04,0.0028,23899.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-18",24,23.53,3029.98,,0.007,0.001,1404.844,0.0591,0.021,0.0018,23635.761,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-19",18,17.45,2391,,0.006,0.001,1098.33,0.059,0.036,0.0044,18480.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-20",20,18.65,1217.9,,0.004,0.001,702.14,0.0591,0.024,0.0088,11811.465,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-21",24,24,4254,,0.009,0.001,1815.1,0.059,0.068,0.004,30540.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-22",24,23.71,3432.97,,0.008,0.001,1564.565,0.059,0.054,0.0035,26322.618,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-23",24,24,3473,,0.008,0.001,1569,0.0591,0.06,0.004,26393.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-24",24,24,3525,,0.008,0.001,1582.4,0.059,0.059,0.0041,26625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-25",24,24,2781,,0.007,0.001,1332.8,0.0592,0.052,0.0041,22421.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-26",18,16.09,1039.57,,0.003,0.001,608.386,0.059,0.01,0.0036,10238.871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-27",17,14.76,1025.39,,0.003,0.001,595.392,0.0591,0.021,0.01,10018.793,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-28",9,7.77,766.79,,0.002,0.001,389.608,0.059,0.018,0.0116,6556.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-29",13,11.49,1129.59,,0.003,0.001,567.17,0.0591,0.016,0.0132,9544.598,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-08-31",11,9.73,814.3,,0.002,0.001,436.508,0.0591,0.023,0.0148,7340.508,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-02",4,3.17,141.02,,0.001,0.001,109.532,0.0593,0.016,0.0613,1842.611,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-03",24,24,2756,,0.007,0.001,1294.2,0.0591,0.042,0.0035,21775.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-04",15,14.27,3010.25,,0.006,0.001,1276.38,0.059,0.057,0.0051,21476.836,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-05",24,24,2800,,0.007,0.001,1328.9,0.059,0.041,0.0028,22354.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-06",20,18.6,2731.46,,0.006,0.001,1237.66,0.0591,0.039,0.0045,20826.552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-07",21,19.95,2841.5,,0.007,0.001,1298.265,0.059,0.049,0.0043,21844.835,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-08",19,17.25,2007.3,,0.005,0.001,958.753,0.0593,0.041,0.0051,16126.873,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-09",15,14.4,930.25,,0.003,0.001,540.545,0.059,0.018,0.0043,9093.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-11",23,21.63,5000.9,,0.011,0.001,2092.422,0.059,0.124,0.0198,35208.954,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-12",9,8.45,677.1,,0.002,0.001,357.995,0.059,0.007,0.0022,6025.645,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-14",18,17.42,3003.2,,0.007,0.001,1323.746,0.0591,0.065,0.0112,22275.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-15",16,14.8,2523.46,,0.006,0.001,1109.247,0.059,0.029,0.004,18662.947,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-16",9,8.57,1517.55,,0.003,0.001,666.782,0.0591,0.035,0.0108,11217.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-17",24,24,5283,,0.011,0.001,2212.4,0.059,0.108,0.0056,37227.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-18",3,2.5,541,,0.001,0.001,229.3,0.059,0.012,0.0053,3857.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-27",9,7.8,1303.57,,0.003,0.001,580.664,0.0591,0.037,0.032,9768.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-28",24,24,4744,,0.01,0.001,1992,0.059,0.056,0.0032,33522.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-29",24,24,5563,,0.012,0.001,2283.9,0.059,0.055,0.0028,38429.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-09-30",24,24,4678,,0.01,0.001,1971.6,0.059,0.07,0.0043,33176.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-01",24,24,5769,,0.012,0.001,2359.4,0.059,0.095,0.0048,39700.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-02",24,24,5721,,0.012,0.001,2331.2,0.059,0.087,0.0044,39232.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-03",13,11.63,2316.12,,0.005,0.001,980.615,0.0591,0.043,0.007,16499.611,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-04",9,8.58,1722.54,,0.004,0.001,729.412,0.0591,0.032,0.0096,12273.646,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-05",17,15.75,3413.81,,0.007,0.001,1423.487,0.059,0.057,0.0077,23948.294,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-06",24,23.4,4678.4,,0.01,0.001,1959.46,0.059,0.082,0.0046,32966.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-10",9,8.41,1545.62,,0.003,0.001,682.403,0.059,0.037,0.0103,11482.639,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-11",10,9.03,1771.45,,0.004,0.001,765.996,0.059,0.038,0.0118,12887.458,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-13",10,8.85,594.55,,0.002,0.001,352.11,0.059,0.021,0.0147,5923.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-14",14,13.58,2546.92,,0.006,0.001,1098.43,0.059,0.044,0.0073,18480.656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-15",24,24,5916,,0.012,0.001,2423.8,0.059,0.127,0.0062,40783.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-16",24,24,5436,,0.011,0.001,2246.8,0.059,0.091,0.0046,37806.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-17",11,9.11,1607.64,,0.004,0.001,708.857,0.059,0.034,0.0133,11926.598,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-19",9,8.73,1511.3,,0.003,0.001,672.046,0.059,0.041,0.0138,11307.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-20",24,24,5611,,0.012,0.001,2307.7,0.059,0.103,0.0052,38830,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-21",12,10.9,1847.98,,0.004,0.001,813.03,0.059,0.046,0.0114,13685.872,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-22",17,16.13,2240.45,,0.005,0.001,1021.741,0.059,0.041,0.0065,17197.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-23",24,24,5887,,0.012,0.001,2407.2,0.059,0.119,0.0059,40501,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-24",2,1.68,333.32,,0.001,0.001,142.292,0.059,0.005,0.004,2393.936,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-26",10,9.19,667.83,,0.002,0.001,382.358,0.059,0.03,0.013,6434.216,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-27",9,8.88,1601.76,,0.004,0.001,693.584,0.059,0.04,0.0094,11670.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-28",24,24,5457,,0.011,0.001,2245,0.059,0.119,0.006,37781.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-29",22,21.43,4930.15,,0.01,0.001,2031.336,0.059,0.075,0.0042,34178.741,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-02",10,9.24,1276.29,,0.003,0.001,606.061,0.0591,0.042,0.0196,10198.237,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-03",20,18.67,2431.39,,0.006,0.001,1121.501,0.059,0.042,0.0059,18874.158,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-04",12,11.4,1789,,0.004,0.001,801.78,0.059,0.043,0.0066,13492.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-05",20,17.98,2662.55,,0.006,0.001,1202.492,0.0591,0.052,0.0055,20230.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-09",9,8.22,1084.76,,0.003,0.001,514.308,0.0591,0.038,0.032,8654.894,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-10",10,8.22,1186.59,,0.003,0.001,564.776,0.059,0.042,0.0137,9500.767,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-11",24,24,4258,,0.009,0.001,1848.3,0.059,0.075,0.0043,31101.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-12",10,9.35,1104.8,,0.003,0.001,523.415,0.059,0.018,0.0035,8810.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-13",17,15.6,1827.7,,0.004,0.001,870.02,0.059,0.038,0.0136,14638.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-16",22,21.98,3341.76,,0.008,0.001,1514.068,0.059,0.073,0.007,25475.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-17",24,24,4688,,0.01,0.001,1983.8,0.059,0.074,0.0041,33379.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-18",24,24,3756,,0.008,0.001,1646.6,0.059,0.058,0.0039,27706.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-19",24,24,3183,,0.007,0.001,1457.6,0.059,0.049,0.0034,24523.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-20",24,24,4173,,0.009,0.001,1803.8,0.059,0.058,0.0034,30352,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-21",12,10.53,1698.5,,0.004,0.001,752.433,0.0591,0.026,0.0087,12661.071,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-22",19,18,1748,,0.004,0.001,876.3,0.059,0.017,0.0032,14744.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-23",24,24,3468,,0.008,0.001,1547.6,0.059,0.045,0.003,26044.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-24",17,15.44,1961.09,,0.005,0.001,911.96,0.059,0.035,0.0102,15341.997,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-25",2,1.4,112,,0,0.001,62.3,0.059,0.001,0.002,1047.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-27",9,8.28,657.8,,0.002,0.001,363.1,0.059,0.025,0.0236,6111.464,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-28",16,14.97,1659.25,,0.004,0.001,805.507,0.059,0.036,0.0069,13554.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-29",9,8.37,667.68,,0.002,0.001,356.016,0.059,0.008,0.0029,5991.897,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-11-30",8,7.83,1176.92,,0.003,0.001,532.216,0.059,0.037,0.0129,8956.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-01",3,2.43,166.96,,0,0.001,97.04,0.059,0.002,0.002,1632.126,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-02",10,9.02,1332,,0.003,0.001,606.738,0.059,0.039,0.0153,10211.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-03",10,8.64,1457.15,,0.003,0.001,648.525,0.059,0.035,0.0085,10915.194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-04",11,10.22,1925.42,,0.004,0.001,824.662,0.059,0.045,0.0222,13877.012,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-05",1,0.33,23.43,,0,0.001,15.312,0.059,0,0.002,257.466,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-06",9,8.22,1126.98,,0.003,0.001,521.896,0.059,0.034,0.0336,8779.078,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-07",18,16.61,2266.37,,0.005,0.001,1037.58,0.059,0.049,0.0086,17459.669,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-08",16,15.45,2458.65,,0.005,0.001,1084.55,0.059,0.041,0.0086,18250.655,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-09",24,24,3607,,0.008,0.001,1593.1,0.059,0.049,0.003,26806.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-10",10,9.37,992.12,,0.002,0.001,476.534,0.059,0.012,0.0025,8017.622,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-11",10,9.83,1931.94,,0.004,0.001,826.756,0.059,0.063,0.0154,13910.889,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-12",4,2.77,283.38,,0.001,0.001,149.71,0.059,0.023,0.0415,2518.663,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-13",18,16.89,2116.67,,0.005,0.001,987.406,0.0591,0.049,0.0086,16611.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-14",24,24,3536,,0.008,0.001,1587.7,0.059,0.059,0.0037,26715.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-15",24,24,3954,,0.009,0.001,1726,0.059,0.059,0.0038,29037.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-16",24,24,4022,,0.009,0.001,1747.9,0.059,0.055,0.0037,29408.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-17",4,3.18,262.68,,0.001,0.001,138.152,0.059,0.003,0.0025,2324.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-18",11,9.58,1539.58,,0.004,0.001,698.606,0.059,0.047,0.0307,11757.486,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-19",11,10.13,1440.58,,0.003,0.001,670.057,0.059,0.033,0.0086,11272.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-20",19,17.38,2480.77,,0.006,0.001,1142.002,0.059,0.045,0.0083,19216.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-21",24,24,3099,,0.007,0.001,1446.7,0.059,0.046,0.0032,24342.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-22",17,15.95,1368.62,,0.004,0.001,732.278,0.059,0.035,0.0156,12321.195,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-23",24,24,3905,,0.009,0.001,1740.8,0.059,0.069,0.004,29292.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-24",24,24,4761,,0.01,0.001,2037.5,0.059,0.092,0.005,34284.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-25",9,8.37,676.16,,0.002,0.001,362.312,0.059,0.01,0.0032,6096.481,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-28",10,8.85,1367.04,,0.003,0.001,635.676,0.059,0.046,0.0197,10698.289,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-29",10,9.88,1749.12,,0.004,0.001,771,0.059,0.051,0.0118,12972.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-30",8,7.29,926.29,,0.002,0.001,443.895,0.059,0.025,0.0096,7470.247,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-3",,"2020-12-31",9,8.4,778,,0.002,0.001,401.56,0.059,0.008,0.0022,6757.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-06",11,10.38,2088.04,,0.005,0.001,914.674,0.059,0.097,0.037,15392.502,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-07",1,0.42,36.96,,0,0.001,22.638,0.059,0.001,0.006,380.646,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-15",11,9.96,1927.26,,0.004,0.001,853.468,0.0591,0.095,0.0383,14358.878,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-17",14,12.33,2427.76,,0.005,0.001,1066.87,0.059,0.15,0.0581,17952.218,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-18",1,0.68,89.76,,0,0.001,45.084,0.059,0.002,0.004,758.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-20",12,10.68,2157.88,,0.005,0.001,942.584,0.0591,0.091,0.0347,15860.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-23",10,9.02,1753.3,,0.004,0.001,771.269,0.059,0.076,0.0354,12975.069,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-24",6,5.45,1269.55,,0.003,0.001,531.99,0.059,0.033,0.0077,8951.425,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-25",3,2.02,11.5,,0,0.001,18.154,0.059,0.025,0.1943,306.118,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-26",18,16.09,695.43,,0.003,0.001,520.555,0.0591,0.074,0.0407,8763.394,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-27",4,0.39,0,,0,0.001,9.484,0.059,0.026,0.315,159.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-28",6,3.71,214.92,,0.001,0.001,199.554,0.059,0.062,0.0882,3356.047,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-29",24,24,4061,,0.013,0.001,2562,0.059,0.144,0.0066,43106.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-30",24,24,1727,,0.007,0.001,1395.9,0.059,0.062,0.0056,23489.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-03-31",19,18.28,2174,,0.005,0.001,1023.844,0.059,0.096,0.0242,17232.172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-01",1,0.25,1.5,,0,0.001,7.275,0.06,0.015,0.25,122.225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-26",5,3.35,204.7,,0.001,0.001,137.79,0.059,0.042,0.0626,2318.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-27",10,9.26,1861,,0.004,0.001,812.792,0.059,0.056,0.0124,13676.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-28",10,8.62,1627.74,,0.004,0.001,720.808,0.059,0.054,0.0262,12129.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-02",12,9.96,1591.09,,0.004,0.001,741.6,0.059,0.11,0.0425,12479.793,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-03",15,14.14,3030.91,,0.007,0.001,1314.033,0.059,0.087,0.0128,22112.648,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-04",13,11.93,2162.28,,0.005,0.001,950.629,0.059,0.063,0.0182,15999.942,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-10",13,12.3,2263.3,,0.005,0.001,1006.705,0.0591,0.085,0.0152,16937.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-11",12,11.07,2237,,0.005,0.001,966.277,0.059,0.072,0.0296,16258.143,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-12",4,3.53,239.44,,0.001,0.001,136.304,0.059,0.009,0.0083,2294.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-06",9,8.97,566.7,,0.002,0.001,354.173,0.059,0.038,0.0157,5960.291,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-07",10,9.09,824.92,,0.002,0.001,432.581,0.059,0.03,0.0114,7281.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-08",10,8.5,1199.34,,0.003,0.001,566.423,0.059,0.039,0.0124,9531.567,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-09",8,7.13,1295.65,,0.003,0.001,584.426,0.059,0.045,0.0144,9834.913,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-10",11,9.55,1883,,0.004,0.001,829.81,0.059,0.043,0.0185,13963.785,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-11",7,6.12,496.16,,0.001,0.001,286.67,0.059,0.035,0.0309,4824.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-12",12,10.74,1450.82,,0.003,0.001,674.379,0.059,0.033,0.0204,11349.293,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-13",8,7.2,571.8,,0.002,0.001,318.428,0.059,0.022,0.0089,5357.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-14",11,9.3,971.02,,0.002,0.001,492.64,0.059,0.026,0.0085,8288.424,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-15",10,8.88,967.63,,0.002,0.001,481.144,0.059,0.027,0.0122,8095.411,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-16",9,8.15,786.5,,0.002,0.001,406.88,0.059,0.023,0.0089,6846.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-17",9,7.48,1033.52,,0.002,0.001,486.133,0.059,0.032,0.0338,8178.125,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-19",11,9.43,659.99,,0.002,0.001,384.616,0.059,0.028,0.0345,6472.827,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-20",13,11.99,1501.48,,0.004,0.001,720.982,0.059,0.04,0.012,12132.917,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-21",9,7.75,774.15,,0.002,0.001,397.04,0.059,0.038,0.0223,6681.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-27",9,8.52,1063.2,,0.003,0.001,505.008,0.059,0.045,0.0217,8496.172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-28",10,8.23,1553.08,,0.003,0.001,689.598,0.059,0.048,0.0333,11604.039,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-29",11,10.25,2108.24,,0.005,0.001,912.865,0.059,0.063,0.0116,15360.599,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-30",10,8.9,1748.81,,0.004,0.001,761.669,0.059,0.053,0.0173,12814.922,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-07-31",8,6.91,1319.58,,0.003,0.001,584.905,0.059,0.046,0.052,9842.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-01",11,10.07,1524.48,,0.003,0.001,688.62,0.059,0.052,0.0324,11588.339,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-03",8,7.2,967.4,,0.002,0.001,452.9,0.059,0.033,0.038,7619.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-04",1,0.43,37.84,,0,0.001,22.016,0.059,0.001,0.008,370.402,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-06",16,15.33,796.4,,0.003,0.001,657.548,0.0591,0.062,0.0214,11064.529,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-09",10,9.57,856.7,,0.002,0.001,454.185,0.059,0.031,0.0152,7641.767,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-10",10,8.78,953.74,,0.002,0.001,475.75,0.059,0.022,0.0064,8002.504,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-11",10,8.52,1100.2,,0.003,0.001,520.42,0.059,0.032,0.0216,8755.898,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-12",15,13.95,1895.71,,0.004,0.001,873.857,0.0591,0.057,0.0109,14701.747,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-13",18,17.5,3947.5,,0.008,0.001,1675.7,0.059,0.101,0.0104,28194.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-14",24,24,3655,,0.008,0.001,1646.4,0.0591,0.075,0.0042,27700.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-15",24,24,4168,,0.009,0.001,1824.8,0.0591,0.057,0.0035,30704.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-16",24,24,2164,,0.006,0.001,1101.2,0.0592,0.022,0.0022,18521.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-17",24,24,3152,,0.007,0.001,1464.4,0.0592,0.049,0.0032,24634.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-18",24,23.58,3297.5,,0.008,0.001,1519.676,0.059,0.032,0.0023,25574,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-19",16,14.62,1777.8,,0.004,0.001,850.168,0.0591,0.025,0.0088,14306.516,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-20",16,15.02,1003,,0.003,0.001,571.332,0.0598,0.026,0.0061,9603.194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-21",18,16.12,1500.44,,0.004,0.001,751.976,0.0591,0.044,0.011,12652.944,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-22",9,7.87,1123.69,,0.003,0.001,521.755,0.059,0.036,0.0176,8778.311,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-23",16,15.3,1552.3,,0.004,0.001,765.4,0.0591,0.029,0.0099,12879.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-24",20,18.83,1668.2,,0.004,0.001,860.452,0.0593,0.046,0.0091,14473.646,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-25",22,21.42,1622.56,,0.004,0.001,876.084,0.059,0.03,0.004,14734.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-26",16,15.1,1004.86,,0.003,0.001,582.314,0.059,0.022,0.0059,9798.468,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-27",16,15.35,1083.47,,0.003,0.001,609.574,0.059,0.032,0.0066,10261.523,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-28",8,7.17,745.94,,0.002,0.001,376.932,0.059,0.03,0.0143,6340.926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-29",12,11.09,1098.67,,0.003,0.001,554.275,0.0591,0.032,0.0099,9324.441,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-08-31",9,8.3,613.7,,0.002,0.001,346.66,0.059,0.032,0.0262,5836.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-01",1,0.42,24.36,,0,0.001,17.892,0.059,0.001,0.007,301.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-02",10,9.98,904.66,,0.002,0.001,475.77,0.059,0.044,0.0133,8005.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-03",23,22.42,2709.5,,0.006,0.001,1267.472,0.059,0.071,0.0067,21325.248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-04",20,19.06,1716.4,,0.004,0.001,878.394,0.059,0.047,0.0073,14775.216,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-05",21,20.53,1803.19,,0.005,0.001,931.237,0.059,0.055,0.0083,15673.761,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-06",23,22.42,2325.04,,0.006,0.001,1141.58,0.059,0.06,0.006,19211.852,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-07",20,18.93,2338.13,,0.006,0.001,1253.989,0.059,0.071,0.0083,21103.738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-08",16,14.45,1874.3,,0.004,0.001,879.845,0.059,0.057,0.0198,14804.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-09",14,12.76,823.72,,0.002,0.001,477.38,0.0591,0.024,0.0136,8033.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-14",14,11.73,2109.89,,0.005,0.001,949.228,0.059,0.083,0.0277,15969.357,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-15",15,13.85,2278.01,,0.005,0.001,1016.528,0.059,0.058,0.0111,17103.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-16",7,6.41,718.2,,0.002,0.001,376.725,0.059,0.044,0.0234,6341.613,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-17",23,22.24,4576.08,,0.01,0.001,1958.693,0.059,0.099,0.0088,32954.463,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-18",24,23.48,5136.44,,0.011,0.001,2173.932,0.059,0.122,0.0063,36578.476,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-27",12,11.33,1999.3,,0.005,0.001,904.562,0.059,0.068,0.0233,15222.639,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-28",24,24,4740,,0.01,0.001,2024.3,0.059,0.096,0.005,34060,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-29",24,24,5559,,0.012,0.001,2322,0.059,0.077,0.0039,39074.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-09-30",24,24,4575,,0.01,0.001,1964.2,0.059,0.106,0.0059,33053.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-01",24,24,5895,,0.012,0.001,2437.9,0.059,0.126,0.0062,41018.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-02",24,24,5794,,0.012,0.001,2387.9,0.059,0.134,0.0066,40183.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-03",14,12.29,2509.52,,0.005,0.001,1072.955,0.0591,0.067,0.0116,18051.687,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-04",10,9.58,1987.12,,0.004,0.001,848.944,0.059,0.057,0.0162,14284.648,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-05",23,21.49,4954.29,,0.01,0.001,2070.869,0.059,0.12,0.0143,34849.695,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-06",24,24,4838,,0.01,0.001,2055.6,0.059,0.113,0.0061,34586.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-07",12,10.4,1832.9,,0.004,0.001,810.705,0.059,0.059,0.0126,13642.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-10",11,10.4,1857.49,,0.004,0.001,830.612,0.059,0.075,0.0164,13975.515,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-11",10,9.02,1882,,0.004,0.001,813.734,0.0591,0.065,0.0176,13692.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-12",12,10.93,1870.86,,0.004,0.001,836.209,0.059,0.066,0.0149,14069.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-13",24,24,2674,,0.007,0.001,1289.2,0.059,0.069,0.0063,21693,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-14",16,14.89,2710,,0.006,0.001,1199.269,0.0591,0.08,0.0158,20183.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-15",24,24,5961,,0.013,0.001,2482.1,0.059,0.152,0.0073,41763.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-16",24,24,5417,,0.011,0.001,2267.9,0.059,0.13,0.0066,38158.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-17",24,24,4734,,0.01,0.001,2033,0.059,0.107,0.0056,34211.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-18",22,21.12,4670.8,,0.01,0.001,1976.08,0.059,0.117,0.0105,33253.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-19",10,8.8,1756.3,,0.004,0.001,765.64,0.0591,0.064,0.0239,12882.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-20",24,24,5410,,0.011,0.001,2270.3,0.059,0.127,0.0065,38204.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-21",11,10.06,1463.58,,0.003,0.001,672.266,0.059,0.038,0.0115,11314.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-22",18,16.92,2629.96,,0.006,0.001,1175.952,0.0591,0.06,0.0117,19788.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-23",24,24,5881,,0.012,0.001,2432.6,0.059,0.162,0.0079,40928.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-24",8,7.72,1430.48,,0.003,0.001,612.748,0.059,0.038,0.0083,10310.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-26",10,8.8,1061.33,,0.003,0.001,513.029,0.0591,0.054,0.0327,8631.256,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-27",10,9.22,1871.2,,0.004,0.001,802.864,0.0591,0.064,0.0339,13510.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-28",9,8.68,2011.8,,0.004,0.001,842.216,0.059,0.055,0.0074,14171.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-02",12,11.48,2141.8,,0.005,0.001,943.52,0.059,0.077,0.021,15876.648,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-03",24,24,5046,,0.011,0.001,2122.6,0.059,0.133,0.007,35715.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-04",13,11.46,1874.66,,0.004,0.001,845.205,0.059,0.064,0.0145,14218.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-05",12,10.82,2253.28,,0.005,0.001,968.395,0.059,0.068,0.019,16295.866,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-07",10,9.38,1569.18,,0.004,0.001,703.856,0.059,0.056,0.0289,11844.452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-08",16,15.18,1039.68,,0.003,0.001,585.898,0.0591,0.011,0.0023,9861.806,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-09",8,7.72,851.24,,0.002,0.001,420.644,0.059,0.033,0.0179,7078.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-10",3,1.45,62.15,,0,0.001,57.124,0.059,0.026,0.151,960.521,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-11",9,8.6,870.6,,0.002,0.001,438.32,0.059,0.012,0.0028,7372,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-13",21,19.47,2067.78,,0.005,0.001,1025.791,0.059,0.08,0.028,17257.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-14",15,14.08,966.7,,0.003,0.001,553.844,0.0591,0.059,0.0152,9317.972,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-15",2,1.92,89,,0,0.001,71.568,0.059,0.024,0.044,1203.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-16",20,19,2301.06,,0.006,0.001,1098.082,0.059,0.069,0.0092,18479.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-17",10,9.47,955.9,,0.002,0.001,472.008,0.0591,0.024,0.006,7941.464,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-18",19,17.56,1479.37,,0.004,0.001,789.922,0.059,0.061,0.0139,13289.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-19",21,19.81,2495.89,,0.006,0.001,1177.296,0.059,0.099,0.0207,19812.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-20",23,22.55,3958.66,,0.009,0.001,1727.64,0.059,0.128,0.0105,29070.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-21",9,8.5,859,,0.002,0.001,428.35,0.059,0.024,0.0068,7206.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-15",9,8.6,900.2,,0.002,0.001,455.04,0.059,0.053,0.0271,7657.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-16",2,1.43,133.38,,0,0.001,70.222,0.059,0.004,0.007,1181.134,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-25",12,11.32,791.2,,0.002,0.001,460.244,0.0591,0.061,0.0292,7745.932,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-26",9,8.38,628.36,,0.002,0.001,344.192,0.059,0.022,0.0077,5791.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-28",12,11.6,1953.8,,0.004,0.001,874.38,0.059,0.086,0.0229,14714.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-29",22,20.21,2684.04,,0.006,0.001,1258.907,0.059,0.086,0.0151,21188.261,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-30",18,16.88,2421.7,,0.006,0.001,1101.054,0.059,0.082,0.0206,18529.326,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","La Paloma Generating Plant",55151,"CTG-4",,"2020-12-31",20,18.62,2555.2,,0.006,0.001,1182.394,0.059,0.077,0.0153,19896.858,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-01",18,17.6,3918.1,,0.008,0.001,1572.57,0.059,0.067,0.0056,26463.42,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-02",24,24,5528,,0.011,0.001,2221.4,0.059,0.088,0.0047,37376.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-03",24,24,5650,,0.011,0.001,2262.9,0.059,0.085,0.0044,38076.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-04",24,24,5375,,0.011,0.001,2142,0.059,0.077,0.0043,36038.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-05",20,18.76,4518.16,,0.009,0.001,1823.808,0.059,0.088,0.0057,30688.036,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-06",24,24,5779,,0.012,0.001,2340.9,0.059,0.09,0.0045,39389.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-07",21,20.12,4435.5,,0.009,0.001,1801.414,0.059,0.091,0.009,30313.364,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-08",23,22.39,4896.69,,0.01,0.001,2007.833,0.059,0.083,0.005,33787.56,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-09",24,24,5590,,0.011,0.001,2274.1,0.059,0.096,0.005,38266.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-10",24,24,5824,,0.012,0.001,2358.4,0.059,0.092,0.0046,39684.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-11",19,17.87,3988.92,,0.008,0.001,1617.965,0.059,0.066,0.0066,27225.011,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-12",19,17.93,4066.37,,0.008,0.001,1644.339,0.059,0.069,0.0067,27668.166,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-13",24,24,5300,,0.011,0.001,2166.2,0.059,0.084,0.0045,36450.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-14",20,19.23,4346.18,,0.009,0.001,1777.353,0.059,0.076,0.0057,29907.332,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-15",24,24,5573,,0.011,0.001,2271.1,0.059,0.095,0.0049,38216.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-16",24,24,5546,,0.011,0.001,2238.6,0.059,0.091,0.0048,37671,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-17",24,24,5611,,0.012,0.001,2289.1,0.059,0.091,0.0046,38518.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-18",24,24,5581,,0.011,0.001,2256,0.059,0.085,0.0044,37968,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-19",24,24,5810,,0.012,0.001,2340.3,0.059,0.093,0.0047,39383.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-20",24,24,6327,,0.013,0.001,2578.2,0.059,0.112,0.0051,43383.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-21",24,24,5392,,0.011,0.001,2172.3,0.059,0.08,0.0044,36554,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-22",24,24,5256,,0.011,0.001,2129.4,0.059,0.08,0.0044,35830.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-23",24,24,5725,,0.012,0.001,2318.3,0.059,0.092,0.0046,39010.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-24",24,24,5359,,0.011,0.001,2167.7,0.059,0.083,0.0045,36476.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-25",24,24,5508,,0.011,0.001,2249.2,0.059,0.09,0.0047,37850.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-26",21,20.41,4602.98,,0.009,0.001,1853.607,0.059,0.078,0.0055,31192.256,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-27",24,24,5171,,0.011,0.001,2104.7,0.059,0.079,0.0044,35414.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-28",24,24,5292,,0.011,0.001,2157.4,0.059,0.082,0.0045,36304.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-29",24,24,5704,,0.012,0.001,2322.4,0.059,0.093,0.0047,39077.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-30",24,24,5756,,0.012,0.001,2330.9,0.059,0.093,0.0047,39219.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-01-31",24,24,5397,,0.011,0.001,2203.2,0.059,0.085,0.0045,37072.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-01",19,18.51,4487.69,,0.009,0.001,1846.386,0.059,0.089,0.0067,31073.345,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-02",18,17.26,4212.59,,0.009,0.001,1729.446,0.059,0.101,0.0092,29097.555,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-03",21,20.33,5000.97,,0.01,0.001,2044.16,0.059,0.093,0.0059,34398.754,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-04",22,20.89,4863.48,,0.01,0.001,1982.131,0.059,0.09,0.0062,33352.022,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-05",22,21.33,4812.74,,0.01,0.001,1951.934,0.059,0.08,0.0054,32847.153,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-06",19,18.16,4000.38,,0.008,0.001,1615.768,0.059,0.069,0.0067,27190.508,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-07",21,20.02,4558.08,,0.009,0.001,1851.725,0.059,0.08,0.0059,31159.347,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-08",18,17.02,4119.67,,0.008,0.001,1676.252,0.059,0.088,0.0086,28206.508,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-09",17,16.05,3806.61,,0.008,0.001,1549.947,0.059,0.087,0.0093,26079.091,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-10",24,24,5539,,0.011,0.001,2254.4,0.059,0.093,0.0048,37933.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-11",20,19.23,4560.65,,0.009,0.001,1872.333,0.059,0.086,0.0061,31509.254,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-12",24,22.98,5092.18,,0.011,0.001,2088.028,0.059,0.089,0.0054,35140.15,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-13",24,24,5697,,0.012,0.001,2323.7,0.059,0.102,0.0051,39103.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-14",20,19.37,4883.79,,0.01,0.001,2003.146,0.059,0.094,0.0061,33701.506,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-15",22,20.93,4961.99,,0.01,0.001,2029.787,0.059,0.088,0.0066,34157.793,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-16",17,15.95,3765.46,,0.008,0.001,1542.707,0.059,0.089,0.0101,25959.091,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-17",24,24,5383,,0.011,0.001,2204.3,0.059,0.091,0.0048,37091.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-18",24,24,5880,,0.012,0.001,2384.4,0.059,0.097,0.0048,40119.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-19",22,20.84,5111.97,,0.011,0.001,2113.087,0.059,0.108,0.0087,35552.86,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-20",24,24,5717,,0.012,0.001,2330,0.059,0.094,0.0047,39206.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-21",24,24,5816,,0.012,0.001,2360.2,0.059,0.097,0.0048,39714.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-22",24,24,5366,,0.011,0.001,2165.3,0.059,0.083,0.0045,36437.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-23",16,15.83,3561.63,,0.007,0.001,1453.262,0.059,0.064,0.0056,24453.022,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-24",19,17.78,4278.76,,0.009,0.001,1760.854,0.059,0.078,0.0071,29628.608,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-25",21,20.18,4895.96,,0.01,0.001,2011.766,0.059,0.089,0.0059,33855.748,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-26",20,19.18,4634.08,,0.01,0.001,1901.043,0.059,0.085,0.0061,31987.598,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-27",24,24,5561,,0.011,0.001,2266.5,0.059,0.089,0.0046,38136.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-28",24,24,5539,,0.011,0.001,2241.1,0.059,0.086,0.0045,37709.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-02-29",18,16.8,3649.48,,0.008,0.001,1508.636,0.059,0.095,0.0141,25385.496,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-01",1,0.3,33,,0,0.001,13.62,0.059,0.002,0.021,229.23,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-15",1,0.73,0,,0,0.001,17.447,0.06,0.025,0.173,293.022,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-16",19,17.98,2777,,0.007,0.001,1462.325,0.059,0.104,0.0133,24608.377,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-17",24,24,5659,,0.012,0.001,2290,0.059,0.092,0.0048,38537.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-18",24,24,5980,,0.012,0.001,2443.1,0.059,0.103,0.005,41106.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-19",24,24,5946,,0.012,0.001,2442.6,0.059,0.103,0.005,41100.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-20",24,24,5695,,0.012,0.001,2336.6,0.059,0.092,0.0046,39318.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-21",18,17.16,3894.7,,0.009,0.001,1712.454,0.059,0.085,0.0076,28817.394,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-22",24,24,5634,,0.012,0.001,2375.8,0.059,0.105,0.0052,39975.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-23",20,18.96,4099.77,,0.009,0.001,1783.22,0.059,0.079,0.0064,30007.469,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-24",19,18.55,4110.34,,0.009,0.001,1744.493,0.059,0.078,0.0058,29352.583,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-25",20,19.3,4288.55,,0.009,0.001,1804.28,0.059,0.08,0.0059,30362.365,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-26",18,17.05,3650.28,,0.008,0.001,1579.872,0.059,0.073,0.0068,26588.664,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-27",17,16.57,3865.8,,0.008,0.001,1649.527,0.059,0.097,0.0098,27757.856,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-28",19,17.95,4173.1,,0.009,0.001,1762.99,0.059,0.079,0.0065,29663.03,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-29",17,16.16,3740.03,,0.008,0.001,1608.737,0.059,0.098,0.0114,27068.518,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-30",18,17.28,3944.1,,0.009,0.001,1687.814,0.059,0.08,0.0067,28400.536,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-03-31",20,19.55,4177.85,,0.009,0.001,1765.028,0.059,0.073,0.0053,29700.183,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-01",17,16.8,3789.36,,0.008,0.001,1628.256,0.059,0.076,0.0058,27398.956,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-02",17,16.27,3604,,0.008,0.001,1529.063,0.059,0.083,0.008,25727.051,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-03",17,16.1,3671.91,,0.008,0.001,1580.273,0.059,0.091,0.0098,26592.343,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-04",17,15.85,3805.08,,0.008,0.001,1658.685,0.059,0.099,0.0119,27909.632,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-05",24,24,6182,,0.013,0.001,2493,0.059,0.111,0.0053,41951.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-06",24,24,6449,,0.013,0.001,2622.9,0.059,0.117,0.0053,44131.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-07",24,24,5684,,0.012,0.001,2298.7,0.059,0.095,0.0048,38681.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-08",24,24,6288,,0.013,0.001,2534.5,0.059,0.114,0.0053,42643.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-09",24,24,6598,,0.014,0.001,2682.9,0.059,0.132,0.0058,45149.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-10",24,24,5894,,0.012,0.001,2328.4,0.059,0.106,0.0054,39181.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-11",17,16.28,3588.3,,0.008,0.001,1486.605,0.059,0.086,0.0086,25013.476,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-12",17,16.03,3708,,0.008,0.001,1561.881,0.059,0.094,0.0092,26283.529,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-13",18,17.06,3924.62,,0.008,0.001,1597.872,0.059,0.079,0.0068,26893.35,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-14",17,16.3,3834.88,,0.008,0.001,1601.696,0.059,0.095,0.0101,26950.226,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-15",16,15.09,3586.66,,0.007,0.001,1444.787,0.059,0.084,0.0098,24310.265,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-16",17,15.75,3751.68,,0.008,0.001,1545.131,0.059,0.092,0.0111,26000.852,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-17",24,24,5458,,0.011,0.001,2199,0.059,0.098,0.0053,37002.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-18",16,15.7,3708.38,,0.008,0.001,1513.142,0.059,0.09,0.0082,25465.502,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-19",15,14.2,3260.58,,0.007,0.001,1348.432,0.059,0.082,0.01,22691.698,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-20",17,15.93,3615.04,,0.007,0.001,1452.866,0.059,0.081,0.0096,24446.667,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-21",4,2.45,300.42,,0.001,0.001,150.419,0.0593,0.039,0.0323,2530.004,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-22",6,4.65,514.3,,0.002,0.001,347,0.059,0.047,0.037,5837.89,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-23",2,0.83,18.4,,0,0.0005,27.338,0.0595,0.019,0.041,459.457,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-24",12,10.31,1525.39,,0.003,0.001,690.781,0.059,0.052,0.0136,11623.902,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-25",8,7.45,1326.2,,0.003,0.001,557.48,0.059,0.025,0.0063,9380.18,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-10",8,7.98,1481.32,,0.003,0.001,646.052,0.059,0.059,0.02,10872.508,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-11",17,16.36,3324.12,,0.007,0.001,1420.084,0.059,0.072,0.0082,23896.166,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-12",17,16.28,3613.16,,0.008,0.001,1591.492,0.059,0.091,0.0081,26782.068,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-13",1,0.23,18.86,,0,0.001,9.66,0.059,0.002,0.021,162.403,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-14",9,8.98,1423,,0.004,0.001,694.018,0.059,0.051,0.0171,11679.594,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-15",13,11.3,2435.5,,0.005,0.001,1047.602,0.059,0.066,0.0094,17626.98,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-16",17,16.31,3552.41,,0.008,0.001,1491.304,0.059,0.079,0.0075,25094.034,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-17",17,16.31,3667.29,,0.008,0.001,1537.412,0.059,0.073,0.0064,25871.845,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-18",19,17.53,3615.76,,0.007,0.001,1483.571,0.0589,0.067,0.0061,24965.646,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-19",11,9.82,1729.5,,0.004,0.001,766.017,0.059,0.052,0.0135,12889.412,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-24",16,15.68,2497,,0.006,0.001,1201.316,0.0591,0.087,0.0182,20215.444,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-25",16,15.16,3276.12,,0.007,0.001,1388.088,0.059,0.081,0.0089,23358.184,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-26",15,13.53,3186.22,,0.007,0.001,1346.138,0.0591,0.084,0.0162,22648.994,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-27",21,20.78,4655.72,,0.01,0.001,1922.936,0.059,0.095,0.0061,32361.526,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-28",24,24,5366,,0.011,0.001,2174.2,0.059,0.092,0.005,36584.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-29",24,24,5178,,0.011,0.001,2090.3,0.059,0.085,0.0048,35171.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-30",16,15.11,3130.9,,0.006,0.001,1286.303,0.059,0.07,0.0086,21643.965,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-05-31",13,12.3,2117.5,,0.005,0.001,904.54,0.059,0.057,0.0086,15218.22,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-01",24,24,5635,,0.012,0.001,2289,0.059,0.098,0.005,38515.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-02",24,24,5804,,0.012,0.001,2356.1,0.059,0.101,0.005,39648.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-03",24,24,5891,,0.012,0.001,2404.1,0.059,0.109,0.0053,40451.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-04",24,24,5634,,0.012,0.001,2316.2,0.059,0.101,0.0052,38970.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-05",18,17.21,3951.29,,0.008,0.001,1647.571,0.059,0.087,0.0076,27724.23,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-06",15,14.3,3073.22,,0.006,0.001,1278.915,0.059,0.074,0.0091,21519.864,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-07",15,14.28,2993.05,,0.006,0.001,1257.292,0.059,0.075,0.0092,21155.748,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-08",18,16.59,3756.15,,0.008,0.0009,1556.61,0.0594,0.094,0.0099,26192.449,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-09",20,19.09,4851.41,,0.01,0.001,2015.189,0.059,0.101,0.0073,33911.058,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-10",21,20.34,5088.4,,0.011,0.001,2079.889,0.059,0.098,0.0062,34995.135,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-11",20,19.36,4743.48,,0.01,0.001,1940.448,0.059,0.091,0.0062,32654.02,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-12",18,16.86,3834.4,,0.008,0.001,1571.198,0.059,0.074,0.0068,26438.544,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-14",13,12.98,2497.98,,0.006,0.001,1130.114,0.059,0.075,0.0154,19012.73,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-15",19,18.55,4200.69,,0.009,0.001,1718.454,0.059,0.079,0.0057,28916.458,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-16",18,17.55,4293.47,,0.009,0.001,1773.651,0.059,0.099,0.0079,29843.744,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-17",18,17.28,4198.27,,0.009,0.001,1712.916,0.059,0.105,0.0089,28820.677,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-18",20,19.52,4474.12,,0.009,0.001,1834.796,0.059,0.096,0.0067,30874.156,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-19",24,24,5497,,0.011,0.001,2217.3,0.059,0.101,0.0053,37308.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-20",12,10.8,2216.65,,0.005,0.0009,899.145,0.0593,0.058,0.0084,15128.296,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-21",17,15.65,3341.95,,0.007,0.001,1369.975,0.0591,0.076,0.0139,23054.695,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-22",24,24,5894,,0.012,0.001,2394.1,0.059,0.117,0.0057,40285.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-23",24,24,5848,,0.012,0.001,2367.5,0.059,0.122,0.006,39838.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-24",24,24,6020,,0.012,0.001,2435.9,0.059,0.13,0.0063,40988.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-25",24,24,5740,,0.012,0.001,2315.7,0.059,0.12,0.0061,38970.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-26",24,24,5921,,0.012,0.001,2394.1,0.059,0.124,0.0061,40283.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-27",16,15.17,3641.07,,0.008,0.001,1493.349,0.059,0.122,0.0176,25132.09,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-28",16,15.27,3587.32,,0.007,0.001,1458.889,0.059,0.095,0.0106,24548.461,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-29",17,16.28,3617.18,,0.007,0.001,1473.747,0.059,0.09,0.0088,24795.281,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-06-30",17,16.38,3740.7,,0.008,0.001,1517.254,0.059,0.098,0.0098,25532.436,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-01",24,24,5557,,0.011,0.001,2221,0.059,0.111,0.0059,37371.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-02",24,24,5432,,0.011,0.001,2184,0.059,0.102,0.0055,36755.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-03",19,18.13,4503.32,,0.009,0.001,1822.003,0.059,0.109,0.0086,30657.834,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-04",17,16.4,3900.04,,0.008,0.001,1576.34,0.059,0.093,0.0086,26528.232,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-05",19,17.92,4307.08,,0.009,0.001,1755.388,0.059,0.097,0.0082,29537.872,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-06",24,24,5371,,0.011,0.001,2142.5,0.059,0.092,0.0051,36052.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-07",24,24,5221,,0.011,0.001,2114.4,0.059,0.096,0.0053,35576.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-08",24,24,5361,,0.011,0.001,2164.6,0.059,0.106,0.0057,36425.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-09",24,24,5575,,0.011,0.001,2243.5,0.059,0.108,0.0056,37753.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-10",24,24,5780,,0.012,0.001,2328.5,0.059,0.112,0.0055,39181.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-11",24,24,5968,,0.012,0.001,2405.5,0.059,0.123,0.006,40474.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-12",20,19.42,4722.6,,0.01,0.001,1917.271,0.059,0.108,0.0072,32267.477,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-13",24,24,5649,,0.011,0.001,2253,0.059,0.111,0.0058,37906.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-14",24,24,5551,,0.011,0.001,2214,0.059,0.104,0.0055,37257.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-15",24,24,5365,,0.011,0.001,2150.5,0.059,0.098,0.0053,36183,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-16",24,24,5118,,0.01,0.001,2057.4,0.059,0.093,0.0053,34622.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-17",24,24,5390,,0.011,0.001,2159.7,0.059,0.1,0.0054,36344.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-18",19,18.32,4277.75,,0.009,0.001,1733.282,0.059,0.094,0.0069,29163.184,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-19",18,16.7,3881.6,,0.008,0.001,1549.13,0.059,0.083,0.0086,26069.22,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-20",24,24,5429,,0.011,0.001,2176.3,0.059,0.104,0.0056,36621.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-21",24,24,5790,,0.012,0.001,2322.1,0.059,0.115,0.0058,39070.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-22",24,24,5542,,0.011,0.001,2213.1,0.059,0.11,0.0059,37234.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-23",24,24,5520,,0.011,0.001,2205.7,0.059,0.103,0.0055,37117.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-24",24,24,5563,,0.011,0.001,2238.7,0.059,0.112,0.0059,37672.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-25",19,18.3,4538.74,,0.009,0.001,1839.196,0.059,0.102,0.0072,30950.73,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-26",19,18.25,4596.25,,0.009,0.001,1866.64,0.059,0.105,0.0073,31407.75,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-27",24,24,5899,,0.012,0.001,2367.6,0.059,0.12,0.006,39834.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-28",24,24,5744,,0.012,0.001,2291.9,0.059,0.111,0.0057,38563.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-29",24,24,5720,,0.012,0.001,2286.3,0.059,0.114,0.0058,38471.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-30",24,24,5607,,0.011,0.001,2235.1,0.059,0.112,0.0059,37607.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-07-31",24,24,5644,,0.011,0.001,2240.7,0.059,0.104,0.0054,37704.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-01",12,9.18,1792.02,,0.004,0.001,725.153,0.0591,0.054,0.0279,12199.771,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-02",20,19.35,4474.09,,0.009,0.001,1780.859,0.059,0.087,0.0063,29967.061,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-03",24,24,5502,,0.011,0.001,2234.4,0.059,0.11,0.0057,37599.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-04",24,23.5,6428.5,,0.014,0.001,2702.35,0.059,0.159,0.007,45475,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-07",20,19.73,3827,,0.009,0.001,1688.047,0.0591,0.114,0.0153,28403.022,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-08",19,18.58,4329.46,,0.009,0.001,1737.726,0.059,0.092,0.0066,29240.64,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-09",19,18.66,4469.04,,0.009,0.001,1800.552,0.059,0.098,0.0068,30298.192,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-10",24,24,5721,,0.012,0.001,2294.1,0.059,0.116,0.006,38604.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-11",20,19.56,4298.88,,0.009,0.001,1747.2,0.059,0.093,0.0066,29400.088,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-12",24,24,5653,,0.011,0.001,2271,0.059,0.115,0.006,38211.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-13",24,24,6070,,0.012,0.001,2464.8,0.059,0.13,0.0062,41477.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-14",24,24,5660,,0.012,0.001,2291.6,0.059,0.113,0.0058,38562.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-15",24,24,5240,,0.011,0.001,2138.7,0.059,0.105,0.0056,35987.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-16",24,24,5378,,0.011,0.001,2179.9,0.059,0.111,0.0059,36682.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-17",24,23.2,5137.4,,0.01,0.001,2073,0.059,0.099,0.0068,34879.78,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-18",15,13.98,1756,,0.006,0.001,1134.283,0.059,0.081,0.0117,19085.413,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-19",10,8.7,965.38,,0.003,0.001,640.122,0.059,0.045,0.0145,10768.592,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-20",10,8.45,852.35,,0.003,0.001,584.21,0.0591,0.058,0.0283,9832,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-21",11,10.45,1225.95,,0.004,0.001,756.53,0.059,0.064,0.0216,12728.055,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-22",24,24,5748,,0.012,0.001,2360.5,0.059,0.124,0.0062,39720.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-23",24,24,5856,,0.012,0.001,2357.6,0.059,0.124,0.0062,39670.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-24",24,24,5947,,0.012,0.001,2398.2,0.059,0.125,0.0062,40357.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-25",24,24,5233,,0.011,0.001,2096,0.059,0.102,0.0058,35270.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-26",18,17,3065.26,,0.006,0.001,1259.753,0.059,0.073,0.0076,21201.43,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-27",12,11.82,2416.52,,0.005,0.001,986.564,0.059,0.077,0.0132,16600.61,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-28",24,24,5296,,0.011,0.001,2110.2,0.059,0.104,0.0058,35509.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-29",24,24,5349,,0.011,0.001,2128.6,0.059,0.102,0.0056,35817.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-30",20,18.91,4116.95,,0.008,0.001,1650.297,0.059,0.091,0.0085,27773.737,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-08-31",24,24,5276,,0.011,0.001,2106.8,0.059,0.102,0.0057,35450.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-01",24,24,5560,,0.011,0.001,2219.8,0.059,0.11,0.0059,37357.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-02",24,24,5362,,0.011,0.001,2141.6,0.059,0.106,0.0058,36036.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-03",24,24,5787,,0.012,0.001,2324,0.059,0.12,0.0061,39102.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-04",24,24,5125,,0.01,0.001,2054.8,0.059,0.1,0.0058,34573.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-05",24,24,4246,,0.009,0.001,1736.3,0.059,0.069,0.0046,29219,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-06",24,24,4935,,0.01,0.001,2005.5,0.059,0.095,0.0055,33745.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-07",24,24,4943,,0.01,0.001,1995.9,0.059,0.1,0.0059,33585.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-08",24,24,4726,,0.01,0.001,1911.5,0.059,0.088,0.0054,32164.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-09",24,24,5466,,0.011,0.001,2167.6,0.059,0.105,0.0058,36469,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-10",24,24,6111,,0.012,0.001,2440.2,0.059,0.128,0.0062,41065,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-11",24,24,6281,,0.013,0.001,2531.9,0.059,0.136,0.0063,42604,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-12",16,15.16,3722.06,,0.008,0.001,1526.772,0.059,0.107,0.0119,25689.854,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-13",24,24,5811,,0.012,0.001,2348.6,0.059,0.123,0.0062,39521.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-14",24,24,5987,,0.012,0.001,2416.4,0.059,0.127,0.0062,40662,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-15",24,24,5902,,0.012,0.001,2383.8,0.059,0.119,0.0059,40111.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-16",24,24,5751,,0.012,0.001,2325.7,0.059,0.121,0.0062,39136.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-17",24,24,6061,,0.012,0.001,2463,0.059,0.131,0.0063,41444.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-18",24,24,5876,,0.012,0.001,2389.8,0.059,0.125,0.0062,40210.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-19",24,24,5723,,0.012,0.001,2323.7,0.059,0.118,0.006,39096.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-20",24,24,5755,,0.012,0.001,2341.2,0.059,0.124,0.0063,39392.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-21",24,24,6010,,0.012,0.001,2429.5,0.059,0.129,0.0063,40880.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-22",24,24,5877,,0.012,0.001,2366.7,0.059,0.121,0.0061,39822.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-23",24,24,5734,,0.012,0.001,2290.2,0.059,0.111,0.0058,38537,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-24",24,24,5252,,0.011,0.001,2108.2,0.059,0.106,0.0059,35471.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-25",20,19.16,4305.15,,0.009,0.001,1736.594,0.059,0.091,0.0069,29221.764,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-26",18,16.92,3878.08,,0.008,0.001,1565.648,0.059,0.096,0.0098,26344.192,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-27",8,7.7,1767.8,,0.004,0.001,705.73,0.059,0.038,0.0068,11872.96,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-05",6,5.57,701.71,,0.002,0.001,339.224,0.059,0.048,0.033,5707.542,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-06",24,24,6012,,0.012,0.001,2424.1,0.059,0.124,0.006,40790.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-07",24,24,5896,,0.012,0.001,2369.7,0.059,0.116,0.0058,39871.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-08",24,24,5913,,0.012,0.001,2370.1,0.059,0.118,0.0059,39885.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-09",24,24,6061,,0.012,0.001,2446.3,0.059,0.127,0.0061,41163.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-10",24,24,5552,,0.011,0.001,2255.1,0.059,0.115,0.006,37944.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-11",19,18.05,4286.51,,0.009,0.001,1738.891,0.059,0.105,0.0103,29260.014,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-12",24,24,5702,,0.012,0.001,2300.8,0.059,0.115,0.0059,38711.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-13",24,24,5429,,0.011,0.001,2169,0.059,0.102,0.0056,36497.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-14",24,24,5592,,0.011,0.001,2241.9,0.059,0.115,0.0061,37721.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-15",24,24,6097,,0.013,0.001,2482.5,0.059,0.131,0.0062,41772.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-16",24,24,5832,,0.012,0.001,2347.6,0.059,0.119,0.0059,39501.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-17",24,24,5633,,0.011,0.001,2257.1,0.059,0.109,0.0057,37981.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-18",24,24,5720,,0.012,0.001,2299.8,0.059,0.114,0.0058,38697.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-19",24,24,5857,,0.012,0.001,2344.5,0.059,0.113,0.0057,39454.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-20",24,24,5825,,0.012,0.001,2337.4,0.059,0.115,0.0058,39334.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-21",24,24,5934,,0.012,0.001,2411.7,0.059,0.124,0.0061,40579.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-22",24,24,5886,,0.012,0.001,2356,0.059,0.121,0.0061,39645.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-23",24,24,5963,,0.012,0.001,2380.8,0.059,0.117,0.0058,40063.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-24",24,24,5903,,0.012,0.001,2361.6,0.059,0.12,0.006,39737.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-25",18,17.43,4299.72,,0.009,0.001,1747.236,0.059,0.104,0.008,29401.658,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-26",24,24,5890,,0.012,0.001,2365.4,0.059,0.115,0.0058,39804.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-27",24,24,5854,,0.012,0.001,2340.7,0.059,0.111,0.0056,39385.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-28",24,24,5549,,0.011,0.001,2218.3,0.059,0.101,0.0054,37329.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-29",24,24,5786,,0.012,0.001,2308.5,0.059,0.107,0.0055,38845.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-30",24,24,5891,,0.012,0.001,2354.9,0.059,0.117,0.0059,39622.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-10-31",24,24,5670,,0.011,0.001,2263.3,0.059,0.107,0.0056,38084.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-01",24,24,5772,,0.012,0.001,2307.4,0.059,0.113,0.0058,38824.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-02",24,24,6367,,0.013,0.001,2560.9,0.059,0.139,0.0064,43089.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-03",24,24,5977,,0.012,0.001,2384.5,0.059,0.12,0.0059,40118,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-04",24,24,5667,,0.011,0.001,2274.7,0.059,0.112,0.0058,38273.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-05",24,24,5759,,0.012,0.001,2305.7,0.059,0.115,0.0059,38793.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-06",24,24,5608,,0.011,0.001,2241.1,0.059,0.113,0.006,37710.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-07",24,24,5193,,0.011,0.001,2082.2,0.059,0.103,0.0058,35035.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-08",24,24,5064,,0.01,0.001,2055.7,0.059,0.086,0.0049,34592.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-09",24,24,5780,,0.012,0.001,2321.1,0.059,0.1,0.005,39054.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-10",24,24,5461,,0.011,0.001,2207.1,0.059,0.094,0.0049,37138.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-11",24,24,5398,,0.011,0.001,2189.4,0.059,0.098,0.0052,36838.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-12",24,24,5330,,0.011,0.001,2180.5,0.059,0.098,0.0053,36685.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-13",24,24,5622,,0.012,0.001,2284.8,0.059,0.102,0.0053,38444,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-14",14,13.22,2285.94,,0.005,0.001,1023.574,0.059,0.083,0.0158,17223.962,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-15",24,24,5168,,0.011,0.001,2116,0.059,0.086,0.0047,35604.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-16",24,24,5531,,0.011,0.001,2249.4,0.059,0.101,0.0053,37848.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-17",24,24,5647,,0.012,0.001,2295.2,0.059,0.109,0.0056,38620.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-18",24,24,5408,,0.011,0.001,2189.1,0.059,0.096,0.0052,36833.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-19",24,24,5209,,0.011,0.001,2134.8,0.059,0.094,0.0052,35920.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-20",24,24,5781,,0.012,0.001,2344.5,0.059,0.106,0.0053,39452.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-21",24,24,5433,,0.011,0.001,2224,0.059,0.097,0.0051,37420.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-22",12,10.27,2060.22,,0.004,0.001,851.135,0.0591,0.073,0.0159,14322.034,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-23",21,20.2,4550.2,,0.009,0.001,1851.53,0.059,0.094,0.0069,31154.98,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-24",24,24,5409,,0.011,0.001,2223.8,0.059,0.103,0.0054,37421.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-25",19,18.03,4163.03,,0.009,0.001,1698.655,0.059,0.094,0.0087,28583.402,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-26",18,17.01,3919.93,,0.008,0.001,1597.063,0.059,0.09,0.0095,26870.24,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-27",19,18.01,4004.31,,0.008,0.001,1627.524,0.059,0.084,0.0087,27386.15,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-28",19,18.26,4388.58,,0.009,0.001,1789.498,0.059,0.101,0.0091,30109.544,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-29",19,18.26,4521.4,,0.009,0.001,1846.57,0.059,0.107,0.0093,31073.31,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-11-30",24,24,5386,,0.011,0.001,2210.3,0.059,0.097,0.005,37195.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-01",20,19.16,4570.36,,0.009,0.001,1877.118,0.059,0.098,0.007,31589.854,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-02",24,24,5436,,0.011,0.001,2213.7,0.059,0.095,0.005,37256,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-03",24,24,5669,,0.012,0.001,2304.2,0.059,0.102,0.0052,38774.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-04",24,24,5592,,0.012,0.001,2281.3,0.059,0.1,0.0051,38385,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-05",24,24,5646,,0.012,0.001,2295.2,0.059,0.099,0.005,38622.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-06",24,24,5379,,0.011,0.001,2191.4,0.059,0.097,0.0052,36873.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-07",24,24,5665,,0.012,0.001,2299.7,0.059,0.108,0.0055,38700.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-08",24,24,5598,,0.011,0.001,2267.9,0.059,0.103,0.0054,38162,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-09",19,17.4,3774.06,,0.008,0.001,1549.362,0.059,0.091,0.0096,26069.696,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-10",24,24,5627,,0.012,0.001,2297.7,0.059,0.11,0.0056,38661.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-11",24,24,5924,,0.012,0.001,2420.2,0.059,0.117,0.0057,40723.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-12",24,24,5678,,0.012,0.001,2329.4,0.059,0.117,0.006,39196.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-13",24,24,5930,,0.012,0.001,2422,0.059,0.117,0.0057,40751.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-14",21,20.28,4689.71,,0.01,0.001,1949.278,0.059,0.102,0.0069,32798.208,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-15",24,23.48,4839.42,,0.01,0.001,1997.742,0.059,0.084,0.0051,33612.058,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-16",24,24,5352,,0.011,0.001,2178.7,0.059,0.09,0.0049,36664.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-17",24,24,5033,,0.01,0.001,2057.4,0.059,0.095,0.0055,34616.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-18",24,24,5211,,0.011,0.001,2125.3,0.059,0.092,0.0051,35762.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-19",19,18.45,4128.76,,0.009,0.001,1685.257,0.059,0.089,0.0078,28354.617,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-20",19,18.43,4110.28,,0.008,0.001,1679.486,0.059,0.089,0.0078,28261.732,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-21",24,24,5431,,0.011,0.001,2199.5,0.059,0.096,0.0052,37009.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-22",24,24,5353,,0.011,0.001,2182.9,0.059,0.094,0.0051,36734.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-23",24,24,5202,,0.011,0.001,2122.3,0.059,0.08,0.0045,35711.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-24",24,24,5821,,0.012,0.001,2362.7,0.059,0.106,0.0053,39756.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-25",10,9.18,2082.06,,0.004,0.001,840.14,0.059,0.038,0.0087,14135.546,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-01",19,18.78,4072.96,,0.008,0.001,1629.166,0.059,0.061,0.0047,27414.922,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-02",24,24,5529,,0.011,0.001,2205,0.059,0.074,0.004,37098.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-03",24,24,5648,,0.011,0.001,2240.5,0.059,0.075,0.004,37702.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-04",24,24,5388,,0.011,0.001,2143.1,0.059,0.072,0.004,36063.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-05",20,19.49,4637,,0.009,0.001,1860.807,0.059,0.069,0.0048,31315.573,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-06",24,24,5780,,0.012,0.001,2317.9,0.059,0.08,0.0041,39004,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-07",20,19.43,4304.65,,0.009,0.001,1715.797,0.059,0.063,0.0047,28874.521,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-08",22,21.5,4717,,0.01,0.001,1906.84,0.059,0.068,0.0045,32080.38,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-09",24,24,5599,,0.011,0.001,2256.6,0.059,0.076,0.004,37968.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-10",24,24,5828,,0.012,0.001,2335.9,0.059,0.08,0.004,39309.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-11",20,19.07,4169.45,,0.008,0.001,1682.851,0.059,0.064,0.0054,28319.292,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-12",20,19.07,4226.48,,0.009,0.001,1700.127,0.059,0.064,0.0053,28608.035,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-13",24,24,5290,,0.011,0.001,2140.4,0.059,0.073,0.004,36015.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-14",19,18.26,4170.51,,0.008,0.001,1673.992,0.059,0.061,0.0048,28167.415,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-15",24,24,5581,,0.011,0.001,2255.6,0.059,0.079,0.0041,37952.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-16",24,24,5542,,0.011,0.001,2215.3,0.059,0.075,0.004,37274.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-17",24,24,5612,,0.011,0.001,2265.9,0.059,0.071,0.0037,38126.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-18",24,24,5569,,0.011,0.001,2224.6,0.059,0.068,0.0036,37430.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-19",24,24,5813,,0.012,0.001,2319.8,0.059,0.074,0.0038,39037.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-20",24,24,6360,,0.013,0.001,2577.3,0.059,0.085,0.0039,43367.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-21",24,24,5372,,0.011,0.001,2136.1,0.059,0.069,0.0038,35947.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-22",24,24,5243,,0.011,0.001,2101.9,0.059,0.068,0.0038,35370.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-23",24,24,5723,,0.012,0.001,2296.3,0.059,0.074,0.0038,38642.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-24",24,24,5359,,0.011,0.001,2149.7,0.059,0.072,0.004,36175.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-25",24,24,5504,,0.011,0.001,2229.6,0.059,0.074,0.004,37517.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-26",22,21.52,4797.72,,0.01,0.001,1941.02,0.059,0.07,0.0045,32660.042,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-27",24,24,5159,,0.01,0.001,2079.1,0.059,0.068,0.0039,34978.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-28",24,24,5287,,0.011,0.001,2134.3,0.059,0.072,0.004,35912.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-29",24,24,5711,,0.012,0.001,2305.5,0.059,0.076,0.0039,38797.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-30",24,24,5757,,0.012,0.001,2314,0.059,0.078,0.004,38938.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-01-31",24,24,5388,,0.011,0.001,2178.2,0.059,0.071,0.0039,36654.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-01",18,17.53,4333.69,,0.009,0.001,1759.561,0.059,0.062,0.0044,29610.354,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-02",17,16.31,4060.5,,0.008,0.001,1642.478,0.059,0.07,0.0064,27636.698,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-03",22,21.53,5196.75,,0.011,0.001,2117.534,0.059,0.076,0.0045,35632.785,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-04",22,21.91,5027.89,,0.01,0.001,2043.252,0.059,0.072,0.0044,34386.649,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-05",23,22.51,4990.98,,0.01,0.001,2029.069,0.059,0.072,0.0046,34147.172,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-06",20,19.28,4168.24,,0.008,0.001,1676.264,0.059,0.061,0.0048,28207.448,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-07",22,21.03,4733.85,,0.01,0.001,1915.87,0.059,0.069,0.0049,32237.06,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-08",19,18.02,4302.2,,0.009,0.001,1748.264,0.059,0.074,0.0073,29417.396,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-09",18,17.13,3996.96,,0.008,0.001,1625.878,0.059,0.074,0.0074,27357.296,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-10",24,24,5541,,0.011,0.001,2232.4,0.059,0.075,0.004,37564.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-11",19,18.4,4438,,0.009,0.001,1798.535,0.059,0.066,0.0048,30262.905,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-12",22,21.6,4845.28,,0.01,0.001,1956.368,0.059,0.067,0.0043,32919.952,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-13",24,24,5715,,0.012,0.001,2317.9,0.059,0.066,0.0033,39001.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-14",21,20.57,5101.81,,0.011,0.001,2090.903,0.059,0.067,0.004,35184.825,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-15",23,22.05,5153.15,,0.011,0.001,2105.215,0.059,0.064,0.0041,35424.61,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-16",18,17.06,3947.77,,0.008,0.001,1614.921,0.059,0.063,0.0063,27175.284,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-17",24,24,5388,,0.011,0.001,2189,0.059,0.061,0.0033,36831.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-18",24,24,5896,,0.012,0.001,2378.3,0.059,0.068,0.0033,40019.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-19",21,20.01,5019.6,,0.01,0.001,2045.236,0.059,0.065,0.0049,34416.184,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-20",24,24,5731,,0.012,0.001,2314,0.059,0.065,0.0033,38937,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-21",24,24,5822,,0.012,0.001,2338,0.059,0.063,0.0032,39342.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-22",24,24,5362,,0.011,0.001,2141.8,0.059,0.057,0.0032,36040.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-23",18,17.03,3747.78,,0.008,0.0009,1525.047,0.059,0.059,0.0053,25663.267,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-24",20,19.05,4489.41,,0.009,0.001,1844.296,0.059,0.061,0.0046,31031.521,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-25",22,21.28,5093.91,,0.011,0.001,2086.885,0.059,0.064,0.004,35116.127,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-26",21,20.28,4824.45,,0.01,0.001,1977.518,0.059,0.063,0.0041,33275.445,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-27",24,24,5564,,0.011,0.001,2242.1,0.059,0.065,0.0034,37723.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-28",24,24,5533,,0.011,0.001,2212.3,0.059,0.066,0.0035,37223.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-02-29",18,16.32,3551.75,,0.007,0.001,1441.241,0.0591,0.061,0.0062,24254.883,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-01",1,0.22,16.06,,0,0.001,7.656,0.059,0.002,0.03,128.744,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-23",10,8.18,1593.96,,0.004,0.001,756.01,0.059,0.043,0.0075,12722.566,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-24",18,17.45,3952.41,,0.008,0.001,1658.404,0.059,0.062,0.0049,27903.37,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-25",19,18.16,4150.13,,0.009,0.001,1724.346,0.059,0.066,0.0052,29014.643,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-26",17,15.93,3484.19,,0.008,0.001,1495.661,0.059,0.072,0.0084,25167.286,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-27",16,15.62,3731.04,,0.008,0.001,1585.134,0.059,0.084,0.0083,26672.732,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-28",18,17.04,4027.3,,0.009,0.001,1685.243,0.059,0.076,0.0078,28359.362,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-29",16,15.34,3617.28,,0.008,0.001,1546.15,0.059,0.077,0.0078,26017.478,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-30",17,16.08,3790.02,,0.008,0.001,1601.354,0.059,0.067,0.0069,26945.194,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-03-31",19,18.35,4019.35,,0.008,0.001,1673.64,0.059,0.062,0.0048,28165.005,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-01",16,15.7,3628.9,,0.008,0.001,1544.41,0.059,0.071,0.0067,25985.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-02",16,15.08,3418.88,,0.007,0.001,1432.362,0.0591,0.072,0.0089,24101.768,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-03",16,15.03,3511.28,,0.008,0.001,1491.831,0.059,0.072,0.0088,25103.352,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-04",16,14.75,3673.44,,0.008,0.001,1585.047,0.059,0.074,0.0099,26668.699,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-05",24,24,6251,,0.013,0.001,2520,0.059,0.085,0.004,42400.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-06",24,24,6521,,0.013,0.001,2643.8,0.059,0.089,0.004,44489.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-07",24,24,5711,,0.012,0.001,2301.4,0.059,0.077,0.004,38724.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-08",24,24,6349,,0.013,0.001,2558.3,0.059,0.095,0.0044,43046.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-09",24,24,6668,,0.014,0.001,2701.5,0.059,0.109,0.0048,45457.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-10",24,24,5954,,0.012,0.001,2343.2,0.059,0.094,0.0048,39430,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-11",16,15.18,3455.11,,0.007,0.001,1404.478,0.059,0.079,0.0086,23636.403,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-12",16,14.91,3578.21,,0.007,0.001,1480.403,0.0591,0.083,0.0096,24910.543,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-13",17,16.2,3819.04,,0.008,0.001,1529.8,0.059,0.079,0.0077,25741.432,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-14",16,15.38,3718.42,,0.008,0.001,1521.02,0.059,0.081,0.008,25595.494,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-15",17,16.01,3695.92,,0.008,0.001,1508.048,0.059,0.085,0.0098,25377.202,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-16",18,16.86,3974.28,,0.008,0.001,1645.304,0.059,0.067,0.0058,27685.542,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-17",24,24,5497,,0.011,0.001,2199.3,0.059,0.09,0.0048,37009.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-18",17,16.83,3910.68,,0.008,0.001,1600.43,0.059,0.072,0.0059,26930.23,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-19",16,15.33,3455.41,,0.007,0.001,1425.927,0.059,0.067,0.0068,23991.01,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-20",18,17.03,3816.08,,0.008,0.001,1523.329,0.059,0.057,0.0054,25633.699,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-21",7,6.26,793.71,,0.002,0.001,454.76,0.059,0.031,0.0104,7654.541,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-22",9,6.68,669.45,,0.002,0.001,458.386,0.059,0.027,0.0184,7713.005,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-23",4,3.75,333.5,,0.001,0.001,240.05,0.0593,0.033,0.0333,4038.15,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-24",24,22.96,3341.54,,0.009,0.001,1728.732,0.059,0.055,0.0049,29085.53,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-25",20,19.24,4245.2,,0.009,0.001,1833.799,0.059,0.051,0.0038,30856.423,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-26",17,15.46,3657.32,,0.008,0.001,1602.514,0.059,0.054,0.0077,26968.369,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-27",13,11.72,2262,,0.005,0.001,1024.188,0.059,0.051,0.0132,17234.828,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-28",21,19.54,4161.34,,0.009,0.001,1820.486,0.059,0.054,0.0059,30634.132,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-29",24,23.22,5251.74,,0.011,0.001,2253.146,0.059,0.059,0.0035,37909.542,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-07",18,17.41,2943.51,,0.007,0.001,1438.605,0.059,0.081,0.0169,24209.543,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-08",12,11.77,2561.54,,0.006,0.001,1182.934,0.059,0.048,0.0078,19903.767,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-09",13,11.55,2509.95,,0.006,0.001,1147.115,0.0591,0.038,0.0086,19302.837,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-10",13,12.28,2233.76,,0.005,0.001,1009.286,0.059,0.034,0.0062,16981.175,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-11",16,15.28,3140.92,,0.007,0.001,1311.058,0.059,0.053,0.0074,22062.604,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-12",9,8.2,1654.8,,0.003,0.001,690.9,0.059,0.019,0.0052,11624.92,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-15",9,8.23,1942.22,,0.004,0.001,798.999,0.059,0.069,0.0303,13447.478,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-16",16,15.18,3386.12,,0.007,0.001,1394.636,0.059,0.059,0.0068,23467.532,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-17",16,15.18,3490.04,,0.007,0.001,1434.372,0.059,0.044,0.0049,24138.472,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-18",17,16.67,3477.48,,0.007,0.001,1397.911,0.059,0.054,0.0058,23523.248,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-19",9,7.16,1396.07,,0.003,0.001,579.725,0.059,0.04,0.0214,9756.817,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-24",10,9.93,1981.88,,0.004,0.001,829.161,0.0591,0.052,0.0155,13953.022,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-25",15,13.95,3079.1,,0.006,0.001,1278.63,0.059,0.058,0.0088,21518.665,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-26",13,12.2,3037.18,,0.006,0.001,1249.218,0.059,0.053,0.0072,21020.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-27",20,19.66,4472.54,,0.009,0.001,1818.804,0.059,0.06,0.0041,30609.582,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-28",24,24,5367,,0.011,0.001,2152.8,0.059,0.064,0.0036,36224.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-29",24,24,5177,,0.01,0.001,2068.3,0.059,0.058,0.0033,34800.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-30",15,14.03,2935.64,,0.006,0.001,1182.624,0.059,0.052,0.008,19901.123,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-05-31",12,10.91,1880.74,,0.004,0.001,782.115,0.0591,0.046,0.0105,13162.213,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-01",24,24,5634,,0.011,0.001,2261.2,0.059,0.065,0.0034,38047.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-02",24,24,5807,,0.012,0.001,2331.4,0.059,0.07,0.0035,39231.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-03",24,24,5895,,0.012,0.001,2384.5,0.059,0.069,0.0034,40123,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-04",21,20.15,4686.69,,0.01,0.001,1900.642,0.059,0.056,0.0045,31980.532,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-05",12,11.33,2491.28,,0.005,0.001,1002.214,0.059,0.043,0.0064,16862.341,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-06",14,13.15,2897.65,,0.006,0.001,1176.775,0.059,0.055,0.0076,19801.285,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-07",14,13.16,2818.2,,0.006,0.001,1158.723,0.059,0.056,0.008,19499.234,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-08",16,15.5,3575.25,,0.007,0.001,1454.123,0.059,0.062,0.0079,24468.333,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-09",19,18,4670.01,,0.01,0.001,1914.363,0.059,0.068,0.0056,32214.216,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-10",20,19.25,4899.19,,0.01,0.001,1974.467,0.059,0.063,0.0044,33224.013,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-11",19,18.37,4592.1,,0.009,0.001,1851.409,0.059,0.065,0.0047,31155.247,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-12",17,15.61,3649.55,,0.007,0.001,1473.606,0.059,0.047,0.0049,24802.252,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-14",9,8.98,2055.42,,0.004,0.001,842.238,0.059,0.066,0.015,14174.712,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-15",18,17.43,4017.44,,0.008,0.001,1614.065,0.059,0.054,0.0042,27161.372,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-16",17,16.4,4127.64,,0.008,0.001,1679.519,0.059,0.086,0.0072,28260.827,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-17",17,16.16,4044.24,,0.008,0.001,1624.787,0.059,0.106,0.0096,27341.303,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-18",19,18.43,4312.87,,0.009,0.001,1739.65,0.059,0.094,0.0069,29271.524,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-19",24,24,5495,,0.011,0.001,2194.4,0.059,0.109,0.0059,36926.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-20",17,16.05,3478.7,,0.007,0.001,1435.671,0.059,0.093,0.0085,24158.803,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-21",17,16.35,3495.55,,0.007,0.001,1429.605,0.059,0.093,0.009,24055.185,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-22",24,24,5886,,0.012,0.001,2365.9,0.059,0.119,0.006,39812,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-23",24,24,5847,,0.012,0.001,2344.6,0.059,0.117,0.0059,39455.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-24",24,24,6036,,0.012,0.001,2416.3,0.059,0.122,0.006,40659.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-25",24,24,5749,,0.012,0.001,2295,0.059,0.116,0.006,38620.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-26",24,24,5927,,0.012,0.001,2371.4,0.059,0.12,0.006,39902.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-27",20,19.01,4648.09,,0.01,0.001,1914.689,0.0591,0.112,0.007,32219.533,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-28",17,16.36,3789.7,,0.008,0.001,1535.838,0.059,0.099,0.0101,25842.034,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-29",18,17.32,3791.12,,0.008,0.001,1544.285,0.059,0.106,0.0104,25986.639,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-06-30",18,17.28,3894.18,,0.008,0.001,1576.268,0.059,0.1,0.0107,26526.598,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-01",24,24,5564,,0.011,0.001,2196.6,0.059,0.111,0.006,36964.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-02",24,24,5433,,0.011,0.001,2160.6,0.059,0.109,0.006,36359.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-03",20,19.03,4644.79,,0.009,0.001,1868.401,0.059,0.104,0.008,31440.139,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-04",18,17.3,4037.68,,0.008,0.001,1626.816,0.059,0.097,0.0093,27373.224,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-05",20,18.83,4454.12,,0.009,0.001,1810.874,0.059,0.1,0.0081,30471.083,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-06",24,24,5365,,0.011,0.001,2115,0.059,0.107,0.006,35588.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-07",24,24,5217,,0.011,0.001,2089.5,0.059,0.104,0.0059,35160.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-08",24,24,5354,,0.011,0.001,2140.4,0.059,0.108,0.006,36017.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-09",24,24,5579,,0.011,0.001,2224.9,0.059,0.112,0.006,37435.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-10",24,24,5774,,0.012,0.001,2304.5,0.059,0.116,0.006,38776.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-11",24,24,5964,,0.012,0.001,2385.5,0.059,0.12,0.006,40143.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-12",21,20.55,4914.59,,0.01,0.001,1989.315,0.059,0.106,0.0067,33470.447,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-13",24,24,5647,,0.011,0.001,2226,0.059,0.112,0.006,37460.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-14",24,24,5548,,0.011,0.001,2186.4,0.059,0.11,0.006,36791.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-15",24,24,5370,,0.011,0.001,2128.9,0.059,0.104,0.0058,35825.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-16",24,24,5099,,0.01,0.001,2031,0.059,0.103,0.006,34175.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-17",24,24,5386,,0.011,0.001,2135.7,0.059,0.108,0.006,35935.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-18",20,19.27,4419.6,,0.009,0.001,1789.836,0.059,0.095,0.0069,30113.629,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-19",19,18.05,4124.1,,0.008,0.001,1645.14,0.059,0.106,0.0097,27682.23,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-20",24,24,5423,,0.011,0.001,2152.5,0.059,0.109,0.006,36216.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-21",24,24,5793,,0.012,0.001,2297.9,0.059,0.116,0.006,38666.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-22",24,24,5536,,0.011,0.001,2186.1,0.059,0.11,0.006,36789.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-23",24,24,5530,,0.011,0.001,2183.1,0.059,0.11,0.006,36734.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-24",24,24,5564,,0.011,0.001,2218.1,0.059,0.112,0.006,37321.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-25",20,19.38,4738.58,,0.01,0.001,1914.506,0.059,0.103,0.0069,32214.418,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-26",20,19.36,4803.64,,0.01,0.001,1943.368,0.059,0.106,0.007,32700.456,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-27",24,24,5911,,0.012,0.001,2345.8,0.059,0.124,0.0063,39473.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-28",24,24,5750,,0.011,0.001,2267.6,0.059,0.114,0.006,38155.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-29",24,24,5726,,0.011,0.001,2262.9,0.059,0.113,0.0059,38076.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-30",24,24,5605,,0.011,0.001,2208.8,0.059,0.112,0.006,37167.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-07-31",24,24,5641,,0.011,0.001,2212.6,0.059,0.112,0.006,37234.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-01",16,14.58,3148.35,,0.006,0.001,1285.396,0.059,0.098,0.0212,21627.851,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-02",21,20.35,4658.1,,0.009,0.001,1843.04,0.059,0.097,0.0066,31017.595,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-03",18,17.63,3671.92,,0.007,0.001,1446.908,0.059,0.075,0.0063,24345.613,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-07",16,15.07,3343.14,,0.007,0.001,1353.623,0.059,0.108,0.0143,22778.235,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-08",20,19.78,4549.32,,0.009,0.001,1817.138,0.059,0.097,0.0066,30577.754,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-09",20,19.8,4690.84,,0.009,0.001,1878.224,0.059,0.099,0.0065,31606.078,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-10",24,24,5736,,0.011,0.001,2271.7,0.059,0.115,0.006,38225.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-11",19,18.41,4105.41,,0.008,0.001,1637.367,0.059,0.088,0.0068,27551.255,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-12",24,24,5659,,0.011,0.001,2246.8,0.059,0.116,0.0061,37805.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-13",24,24,6095,,0.012,0.001,2447.7,0.059,0.124,0.006,41185.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-14",24,24,5673,,0.011,0.001,2270.1,0.059,0.115,0.006,38197,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-15",24,24,5235,,0.011,0.001,2101.7,0.059,0.106,0.006,35368.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-16",24,24,5380,,0.011,0.001,2152.7,0.059,0.109,0.006,36223.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-17",24,23.3,5162.1,,0.01,0.001,2057.09,0.059,0.085,0.0055,34615.43,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-18",18,16.55,2109.18,,0.007,0.001,1329.355,0.059,0.061,0.0148,22366.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-19",13,11.4,1322.76,,0.004,0.001,850.42,0.0591,0.047,0.0098,14306.068,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-20",12,11.28,1243.12,,0.004,0.001,814.58,0.059,0.064,0.0103,13707.288,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-21",14,13.07,1583,,0.005,0.001,962.211,0.0591,0.053,0.006,16189.561,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-22",24,24,5757,,0.012,0.001,2334,0.059,0.079,0.004,39272.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-23",24,24,5879,,0.012,0.001,2338.8,0.059,0.079,0.004,39355.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-24",24,24,5965,,0.012,0.001,2378.4,0.059,0.08,0.004,40019.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-25",24,24,5229,,0.01,0.001,2069.7,0.059,0.07,0.004,34824.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-26",19,18.03,3242.19,,0.007,0.001,1327.88,0.059,0.051,0.005,22342.216,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-27",14,13.25,2643,,0.005,0.001,1088.15,0.0591,0.068,0.0191,18308.75,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-28",24,24,5289,,0.011,0.001,2081.7,0.059,0.07,0.004,35026.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-29",24,24,5337,,0.011,0.001,2098.2,0.059,0.071,0.004,35303.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-30",21,20.03,4293.67,,0.009,0.001,1715.906,0.059,0.064,0.0053,28875.316,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-08-31",24,24,5270,,0.01,0.001,2079.7,0.059,0.07,0.004,34994.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-01",24,24,5570,,0.011,0.001,2194.8,0.059,0.074,0.004,36928.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-02",24,24,5367,,0.011,0.001,2114.9,0.059,0.071,0.004,35589.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-03",24,24,5799,,0.012,0.001,2299.5,0.059,0.076,0.004,38694.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-04",24,24,5135,,0.01,0.001,2038,0.059,0.069,0.004,34293.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-05",24,24,4234,,0.009,0.001,1714.5,0.059,0.058,0.004,28854.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-06",24,24,4939,,0.01,0.001,1983.4,0.059,0.067,0.004,33372.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-07",24,24,4938,,0.01,0.001,1968,0.059,0.066,0.004,33115,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-08",24,24,4730,,0.01,0.001,1887.7,0.059,0.064,0.004,31762.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-09",24,24,5468,,0.011,0.001,2136.3,0.059,0.072,0.004,35942.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-10",24,24,6143,,0.012,0.001,2422.8,0.059,0.087,0.0043,40770,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-11",24,24,6314,,0.013,0.001,2511.8,0.059,0.087,0.0041,42268.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-12",18,16.51,3954.11,,0.008,0.001,1622.264,0.0591,0.076,0.014,27295.905,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-13",24,24,5830,,0.012,0.001,2325.4,0.059,0.082,0.0042,39130.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-14",24,24,6015,,0.012,0.001,2396.4,0.059,0.084,0.0042,40322.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-15",24,24,5923,,0.012,0.001,2360,0.059,0.088,0.0044,39709.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-16",24,24,5769,,0.012,0.001,2301.1,0.059,0.089,0.0046,38719.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-17",24,24,6090,,0.012,0.001,2442.6,0.059,0.097,0.0048,41099.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-18",24,24,5906,,0.012,0.001,2369.6,0.059,0.094,0.0048,39872.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-19",24,24,5735,,0.012,0.001,2298.8,0.059,0.082,0.0043,38680.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-20",24,24,5769,,0.012,0.001,2315.8,0.059,0.09,0.0046,38967.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-21",24,24,6041,,0.012,0.001,2414.2,0.059,0.092,0.0046,40623.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-22",24,24,5892,,0.012,0.001,2340.7,0.059,0.098,0.005,39386.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-23",24,24,5733,,0.011,0.001,2260.3,0.059,0.083,0.0044,38034,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-24",24,24,5252,,0.011,0.001,2081,0.059,0.07,0.004,35014.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-25",21,20.28,4499.18,,0.009,0.001,1801.633,0.059,0.066,0.0047,30318.326,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-26",20,19.14,4286.96,,0.009,0.001,1722.538,0.059,0.063,0.0049,28985.016,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-27",21,20.7,5006.8,,0.01,0.001,2054.77,0.059,0.075,0.0046,34575.92,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-28",24,24,5362,,0.011,0.001,2233.4,0.059,0.075,0.004,37579.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-29",24,24,5747,,0.012,0.001,2364.2,0.059,0.098,0.0048,39782.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-09-30",24,24,5287,,0.011,0.001,2173.4,0.059,0.11,0.006,36574.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-01",24,24,5973,,0.012,0.001,2451.9,0.059,0.124,0.006,41261.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-02",24,23.2,5671.8,,0.012,0.001,2331.84,0.059,0.119,0.0068,39238.44,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-05",12,11.13,1450,,0.004,0.001,793.853,0.0591,0.056,0.0127,13357.846,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-06",24,24,6035,,0.012,0.001,2409.7,0.059,0.122,0.006,40548.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-07",24,24,5910,,0.012,0.001,2345.1,0.059,0.118,0.006,39463.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-08",24,24,5923,,0.012,0.001,2341,0.059,0.118,0.006,39392,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-09",24,24,6089,,0.012,0.001,2424.9,0.059,0.122,0.006,40804.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-10",24,24,5569,,0.011,0.001,2233.8,0.059,0.113,0.006,37589.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-11",20,19.05,4477.54,,0.009,0.001,1802.772,0.059,0.095,0.007,30334.924,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-12",24,24,5725,,0.012,0.001,2278.2,0.059,0.115,0.006,38333.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-13",24,24,5432,,0.011,0.001,2136.3,0.059,0.108,0.006,35952,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-14",24,24,5586,,0.011,0.001,2200.9,0.059,0.111,0.006,37036.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-15",24,24,6031,,0.012,0.001,2371.3,0.059,0.12,0.006,39902.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-16",24,24,5818,,0.012,0.001,2297.4,0.059,0.116,0.006,38658.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-17",24,24,5726,,0.012,0.001,2310.5,0.059,0.117,0.006,38875.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-18",24,24,5779,,0.012,0.001,2313.1,0.059,0.117,0.006,38923.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-19",24,24,5878,,0.012,0.001,2319.6,0.059,0.117,0.006,39036.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-20",24,24,5933,,0.012,0.001,2348.3,0.059,0.119,0.006,39510.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-21",24,24,5672,,0.011,0.001,2236.6,0.059,0.113,0.006,37632.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-22",24,24,5907,,0.012,0.001,2328,0.059,0.116,0.0059,39176.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-23",24,24,5989,,0.012,0.001,2355.2,0.059,0.119,0.006,39631.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-24",24,24,5921,,0.012,0.001,2335.9,0.059,0.118,0.006,39308.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-25",19,18.53,4518.78,,0.009,0.001,1826.321,0.059,0.104,0.0075,30731.009,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-26",24,24,5914,,0.012,0.001,2338.3,0.059,0.116,0.0059,39349.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-27",24,24,5870,,0.012,0.001,2313.3,0.059,0.117,0.006,38927.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-28",24,24,5551,,0.011,0.001,2189.1,0.059,0.111,0.006,36834.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-29",24,24,5799,,0.012,0.001,2279.2,0.059,0.115,0.006,38353.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-30",24,24,5909,,0.012,0.001,2326.4,0.059,0.116,0.0059,39146.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-10-31",24,24,5683,,0.011,0.001,2234,0.059,0.111,0.0059,37591,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-01",24,24,5784,,0.012,0.001,2282.5,0.059,0.115,0.006,38405.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-02",24,24,6390,,0.013,0.001,2532.9,0.059,0.126,0.0059,42621.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-03",24,24,5990,,0.012,0.001,2354.6,0.059,0.117,0.0059,39618.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-04",24,24,5670,,0.011,0.001,2243.8,0.059,0.113,0.006,37757.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-05",24,24,5780,,0.012,0.001,2278.4,0.059,0.115,0.006,38339.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-06",24,24,5617,,0.011,0.001,2209.6,0.059,0.112,0.006,37181.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-07",24,24,5190,,0.01,0.001,2053.1,0.059,0.104,0.006,34545.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-08",24,24,5061,,0.01,0.001,2023.9,0.059,0.102,0.006,34053.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-09",24,24,5786,,0.012,0.001,2288,0.059,0.112,0.0058,38496.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-10",24,24,5460,,0.011,0.001,2174.2,0.059,0.11,0.006,36586.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-11",24,24,5395,,0.011,0.001,2153.4,0.059,0.109,0.006,36237.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-12",24,24,5337,,0.011,0.001,2150.7,0.059,0.109,0.006,36190.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-13",24,24,5628,,0.011,0.001,2252.7,0.059,0.112,0.0059,37904.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-14",11,9.69,1751.21,,0.004,0.001,733.186,0.059,0.032,0.0057,12338.194,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-15",24,24,5170,,0.011,0.001,2088.4,0.059,0.105,0.006,35136.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-16",24,24,5550,,0.011,0.001,2222.4,0.059,0.112,0.006,37400.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-17",24,24,5666,,0.011,0.001,2271.1,0.059,0.113,0.0059,38218.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-18",24,24,5423,,0.011,0.001,2167.7,0.059,0.108,0.0059,36473.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-19",24,24,5216,,0.011,0.001,2107.3,0.059,0.106,0.006,35461.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-20",24,24,5801,,0.012,0.001,2317.4,0.059,0.117,0.006,38998.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-21",24,24,5439,,0.011,0.001,2195.5,0.059,0.111,0.006,36940.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-22",14,12.83,2403.12,,0.005,0.001,1016.159,0.059,0.082,0.0208,17096.545,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-23",24,24,5400,,0.011,0.001,2174.1,0.059,0.108,0.0059,36582.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-24",24,24,5425,,0.011,0.001,2200.9,0.059,0.111,0.006,37035.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-25",20,19.11,4369.12,,0.009,0.001,1770.679,0.059,0.109,0.0093,29798.608,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-26",19,18.1,4118.6,,0.008,0.001,1667.946,0.059,0.108,0.0102,28069.642,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-27",20,19,4180.72,,0.009,0.001,1690.028,0.059,0.11,0.011,28436.724,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-28",20,19.27,4574.92,,0.009,0.001,1851.701,0.059,0.12,0.0108,31160.709,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-29",20,19.27,4728,,0.01,0.001,1920.998,0.059,0.124,0.0109,32326.208,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-11-30",24,24,5394,,0.011,0.001,2186.9,0.059,0.11,0.006,36798.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-01",21,20.3,4770.3,,0.01,0.001,1947.655,0.059,0.107,0.0071,32771.453,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-02",24,24,5439,,0.011,0.001,2182.4,0.059,0.11,0.006,36721.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-03",24,24,5686,,0.011,0.001,2277.5,0.059,0.115,0.006,38327.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-04",24,24,5615,,0.011,0.001,2253.4,0.059,0.114,0.006,37918.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-05",24,24,5652,,0.011,0.001,2256.2,0.059,0.114,0.006,37965.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-06",24,24,5353,,0.011,0.001,2140.1,0.059,0.108,0.006,36011.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-07",24,24,5664,,0.011,0.001,2261.6,0.059,0.114,0.006,38048.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-08",24,24,5606,,0.011,0.001,2232.1,0.059,0.113,0.006,37564.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-09",24,24,5353,,0.011,0.001,2177.8,0.059,0.11,0.006,36646.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-10",24,24,5642,,0.011,0.001,2267.7,0.059,0.114,0.006,38159.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-11",24,24,5957,,0.012,0.001,2404.8,0.059,0.121,0.006,40461.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-12",24,24,5700,,0.012,0.001,2302.1,0.059,0.116,0.006,38736.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-13",24,24,5965,,0.012,0.001,2398.3,0.059,0.121,0.006,40353,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-14",20,19.08,4533.28,,0.009,0.001,1838.045,0.059,0.116,0.0099,30925.134,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-15",24,24,5014,,0.01,0.001,2044.3,0.059,0.103,0.006,34400.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-16",24,24,5346,,0.011,0.001,2144.7,0.059,0.108,0.006,36084,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-17",24,24,5029,,0.01,0.001,2024.3,0.059,0.102,0.006,34064.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-18",24,24,5205,,0.011,0.001,2090.9,0.059,0.106,0.006,35183.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-19",20,19.56,4305.21,,0.009,0.001,1739.486,0.059,0.113,0.0091,29270.93,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-20",20,19.53,4277.09,,0.009,0.001,1730.208,0.059,0.113,0.0092,29113.179,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-21",24,24,5420,,0.011,0.001,2158.8,0.059,0.109,0.006,36329.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-22",24,24,5353,,0.011,0.001,2147.2,0.059,0.108,0.006,36130.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-23",24,24,5182,,0.01,0.001,2075.5,0.059,0.105,0.006,34922.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-24",24,24,5849,,0.012,0.001,2334.6,0.059,0.118,0.006,39286.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-25",10,9.3,2097.7,,0.004,0.001,833.38,0.059,0.044,0.0077,14020.33,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Sunrise Power Company",55182,"CTG2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-01",24,24,5557,,0.011,0.001,2273.8,0.059,0.129,0.0068,38265.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-02",24,24,5275,,0.011,0.001,2149.4,0.059,0.121,0.0068,36169.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-03",24,24,4953,,0.01,0.001,2049.3,0.059,0.118,0.0069,34487.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-04",24,24,6591,,0.013,0.001,2660.1,0.059,0.153,0.0068,44758.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-05",24,24,6558,,0.013,0.001,2619.2,0.059,0.149,0.0068,44072.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-06",24,24,5132,,0.011,0.001,2110.7,0.059,0.121,0.0068,35521.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-07",24,24,5541,,0.012,0.001,2277.8,0.059,0.131,0.0069,38329,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-08",24,24,6135,,0.013,0.001,2507.8,0.059,0.146,0.0069,42196.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-09",24,24,6991,,0.014,0.001,2836.2,0.059,0.163,0.0068,47721.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-10",24,24,6097,,0.012,0.001,2459.9,0.059,0.138,0.0067,41393.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-11",24,24,6158,,0.013,0.001,2507.4,0.059,0.133,0.0063,42189.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-12",24,24,5226,,0.011,0.001,2164.7,0.059,0.126,0.0069,36426.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-13",24,24,5336,,0.011,0.001,2178.1,0.059,0.123,0.0068,36646.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-14",24,24,5018,,0.01,0.001,2075.4,0.059,0.121,0.0069,34923,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-15",24,24,5455,,0.011,0.001,2220.8,0.059,0.126,0.0068,37369.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-16",24,24,6444,,0.013,0.001,2620.4,0.059,0.144,0.0065,44092.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-17",24,24,5151,,0.011,0.001,2119.7,0.059,0.117,0.0066,35667,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-18",24,24,4840,,0.01,0.001,2016.8,0.059,0.117,0.0069,33935.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-19",24,24,5298,,0.011,0.001,2162.7,0.059,0.121,0.0067,36390.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-20",24,24,5731,,0.012,0.001,2316,0.059,0.129,0.0067,38972.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-21",24,24,4613,,0.01,0.001,1938.9,0.059,0.113,0.0069,32626.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-22",24,24,4565,,0.01,0.001,1927.2,0.059,0.113,0.007,32430.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-23",24,24,6190,,0.013,0.001,2519.1,0.059,0.135,0.0064,42390.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-24",24,24,6768,,0.014,0.001,2740.3,0.059,0.143,0.0062,46113.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-25",24,24,6374,,0.013,0.001,2575,0.059,0.149,0.0069,43329.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-26",24,24,6031,,0.012,0.001,2469.7,0.059,0.135,0.0065,41554,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-27",24,24,6738,,0.014,0.001,2751.2,0.059,0.161,0.007,46297.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-28",24,24,6742,,0.014,0.001,2754.2,0.059,0.162,0.007,46346.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-29",24,24,6849,,0.014,0.001,2780.2,0.059,0.162,0.0069,46782.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-30",17,16.17,3606.92,,0.007,0.001,1475.523,0.059,0.12,0.0182,24830.358,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-01-31",24,24,6257,,0.013,0.001,2565.8,0.059,0.13,0.006,43172.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-01",24,24,6410,,0.013,0.001,2578,0.059,0.136,0.0063,43379.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-02",24,24,6577,,0.013,0.001,2642.8,0.059,0.154,0.0069,44467,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-03",24,24,5931,,0.012,0.001,2397.7,0.059,0.139,0.0069,40344.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-04",24,24,5844,,0.012,0.001,2379.3,0.059,0.138,0.0069,40037.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-05",24,24,5838,,0.012,0.001,2378.8,0.059,0.135,0.0068,40029.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-06",24,24,5873,,0.012,0.001,2414.8,0.059,0.138,0.0068,40635.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-07",24,24,5837,,0.012,0.001,2390,0.059,0.14,0.007,40216.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-08",24,24,6306,,0.013,0.001,2560.2,0.059,0.149,0.0069,43080.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-09",24,24,6237,,0.013,0.001,2506.2,0.059,0.143,0.0068,42176.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-10",24,24,5141,,0.011,0.001,2129.1,0.059,0.125,0.007,35826.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-11",24,24,6054,,0.012,0.001,2453,0.059,0.14,0.0068,41280.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-12",24,24,6579,,0.013,0.001,2656.4,0.059,0.144,0.0065,44699.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-13",24,24,6745,,0.014,0.001,2723.4,0.059,0.151,0.0066,45828,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-14",24,24,6622,,0.013,0.001,2659.3,0.059,0.144,0.0065,44745.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-15",24,24,4785,,0.01,0.001,1995.3,0.059,0.117,0.007,33574.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-16",24,24,6177,,0.013,0.001,2513.4,0.059,0.144,0.0068,42289.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-17",24,24,5707,,0.012,0.001,2327.5,0.059,0.131,0.0067,39166.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-18",24,24,6068,,0.013,0.001,2478.7,0.059,0.143,0.0069,41707.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-19",24,24,6458,,0.013,0.001,2614.7,0.059,0.147,0.0067,43996.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-20",20,18.66,3576.86,,0.008,0.001,1502.548,0.059,0.122,0.0195,25283.926,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-21",24,24,5513,,0.011,0.001,2273,0.059,0.133,0.007,38249.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-22",24,24,5130,,0.011,0.001,2120,0.059,0.122,0.0068,35675.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-23",24,24,6209,,0.013,0.001,2483.6,0.059,0.135,0.0065,41790.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-24",24,24,6153,,0.012,0.001,2465.6,0.059,0.135,0.0065,41489.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-25",24,24,5721,,0.012,0.001,2335.4,0.059,0.131,0.0067,39296.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-26",24,24,5599,,0.011,0.001,2276.7,0.059,0.129,0.0068,38310.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-27",24,24,5225,,0.011,0.001,2163.2,0.059,0.122,0.0068,36400.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-28",24,24,4596,,0.01,0.001,1936.7,0.059,0.114,0.007,32587,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-02-29",24,24,5942,,0.012,0.001,2422.5,0.059,0.139,0.0068,40764.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-01",24,24,6188,,0.013,0.001,2508.3,0.059,0.144,0.0068,42205.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-02",24,24,5684,,0.012,0.001,2323,0.059,0.132,0.0068,39090.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-03",24,24,5001,,0.01,0.001,2067.6,0.059,0.118,0.0068,34789.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-04",3,2.17,553.89,,0.001,0.001,223.873,0.059,0.018,0.0283,3767.143,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-06",13,12.35,2838.7,,0.006,0.001,1159.53,0.059,0.177,0.0422,19510.085,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-07",24,24,6618,,0.013,0.001,2653.1,0.059,0.147,0.0066,44643,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-08",24,24,6748,,0.014,0.001,2733.5,0.059,0.14,0.0061,45993.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-09",24,24,6205,,0.013,0.001,2485,0.059,0.14,0.0067,41815.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-10",24,24,5832,,0.012,0.001,2358.1,0.059,0.135,0.0068,39679,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-11",24,24,5421,,0.011,0.001,2221.8,0.059,0.127,0.0068,37382.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-12",24,24,6245,,0.013,0.001,2519.6,0.059,0.146,0.0069,42397.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-13",24,24,5874,,0.012,0.001,2372.4,0.059,0.137,0.0069,39917,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-14",24,24,6214,,0.013,0.001,2536,0.059,0.147,0.0069,42670.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-15",24,24,6197,,0.013,0.001,2536.9,0.059,0.148,0.007,42692,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-16",24,24,6647,,0.014,0.001,2677.7,0.059,0.156,0.0069,45056.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-17",24,24,4806,,0.01,0.001,2000,0.059,0.115,0.0069,33658.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-18",24,24,4732,,0.01,0.001,1979.2,0.059,0.117,0.007,33300.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-19",24,24,4790,,0.01,0.001,2003.8,0.059,0.117,0.007,33714.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-20",24,24,4551,,0.01,0.001,1923,0.059,0.113,0.007,32356.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-21",24,24,4519,,0.01,0.001,1910.9,0.059,0.112,0.007,32156.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-22",24,24,5556,,0.012,0.001,2298.2,0.059,0.132,0.0068,38671.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-23",24,24,5132,,0.011,0.001,2126.4,0.059,0.123,0.0069,35782.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-24",24,24,4570,,0.01,0.001,1930.4,0.059,0.114,0.007,32479.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-25",24,24,5004,,0.01,0.001,2072.9,0.059,0.121,0.0069,34881.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-26",24,24,5714,,0.012,0.001,2335,0.059,0.134,0.0068,39294.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-27",24,24,5123,,0.011,0.001,2120.7,0.059,0.122,0.0069,35681.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-28",24,24,5495,,0.011,0.001,2265.7,0.059,0.131,0.0069,38123.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-29",24,24,6002,,0.012,0.001,2435.3,0.059,0.14,0.0068,40978,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-30",24,24,4975,,0.01,0.001,2067.4,0.059,0.119,0.0068,34788.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-03-31",24,24,4515,,0.01,0.001,1909.4,0.059,0.112,0.007,32132.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-01",24,24,4645,,0.01,0.001,1950.3,0.059,0.113,0.0069,32819.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-02",24,24,6134,,0.013,0.001,2478.3,0.059,0.141,0.0068,41704.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-03",24,24,5547,,0.011,0.001,2250.7,0.059,0.13,0.0069,37872,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-04",24,24,5458,,0.011,0.001,2248.9,0.059,0.132,0.007,37837.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-05",24,24,4988,,0.01,0.001,2070.5,0.059,0.121,0.007,34837.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-06",24,24,4724,,0.01,0.001,1978.4,0.059,0.116,0.007,33290.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-07",24,24,4579,,0.01,0.001,1926.9,0.059,0.113,0.007,32421.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-08",24,24,5025,,0.01,0.001,2069.9,0.059,0.121,0.007,34832.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-09",22,21.72,4729.84,,0.01,0.001,1934.16,0.059,0.119,0.0077,32546.336,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-04-30",1,0.63,15.75,,0,0.001,14.994,0.06,0.025,0.202,251.874,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-01",4,1.68,278.61,,0.001,0.001,119.635,0.0593,0.072,0.0988,2012.484,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-04",9,8.62,1958.08,,0.004,0.001,792.138,0.059,0.094,0.0299,13328.414,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-05",15,14.13,3629.43,,0.007,0.001,1441.565,0.059,0.143,0.0199,24258.113,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-06",7,6.22,1553.34,,0.003,0.001,628.314,0.059,0.095,0.0371,10573.772,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-09",7,6.1,1579.6,,0.003,0.001,633.31,0.059,0.084,0.0306,10655.82,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-10",6,5.3,1183.3,,0.002,0.001,480.33,0.059,0.031,0.0133,8083.36,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-11",12,11.6,3242.6,,0.007,0.001,1302.78,0.059,0.114,0.0204,21918.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-12",24,24,6876,,0.014,0.001,2762.5,0.059,0.161,0.0069,46483.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-13",24,24,6156,,0.012,0.001,2472.4,0.059,0.14,0.0067,41600.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-14",24,24,6848,,0.014,0.001,2730.3,0.059,0.155,0.0068,45941.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-15",24,24,6159,,0.013,0.001,2482.9,0.059,0.141,0.0067,41781.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-16",24,24,6361,,0.013,0.001,2565.5,0.059,0.149,0.0069,43165.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-17",24,24,6006,,0.012,0.001,2390.8,0.059,0.132,0.0066,40226.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-18",24,24,5696,,0.012,0.001,2280.2,0.059,0.129,0.0067,38364.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-19",24,24,5434,,0.011,0.001,2194.8,0.059,0.123,0.0067,36936,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-20",24,24,5542,,0.011,0.001,2238.9,0.059,0.124,0.0065,37670.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-21",24,24,5823,,0.012,0.001,2347.2,0.059,0.122,0.0062,39493.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-22",24,24,5791,,0.012,0.001,2354.5,0.059,0.119,0.006,39616.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-23",24,24,5583,,0.012,0.001,2312.2,0.059,0.117,0.006,38909.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-24",24,24,5695,,0.012,0.001,2301.5,0.059,0.116,0.006,38726,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-25",24,24,6085,,0.013,0.001,2478.9,0.059,0.125,0.006,41709.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-26",24,24,6813,,0.014,0.001,2763.1,0.059,0.139,0.006,46497.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-27",21,20.22,3960.58,,0.008,0.001,1650.17,0.059,0.091,0.0105,27769.006,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-01",10,9.63,2591.96,,0.005,0.001,1033.762,0.059,0.105,0.0258,17394.888,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-02",24,24,6462,,0.013,0.001,2589.3,0.059,0.146,0.0067,43572.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-03",24,24,6209,,0.013,0.001,2493,0.059,0.141,0.0067,41948.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-04",24,24,5914,,0.012,0.001,2391.3,0.059,0.132,0.0066,40237.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-05",23,22.75,5259,,0.011,0.001,2117.175,0.059,0.129,0.0075,35627.575,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-06",6,5.35,1178.55,,0.002,0.001,480.335,0.059,0.078,0.0433,8081.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-07",1,0.73,118.99,,0,0.001,51.246,0.059,0.009,0.022,862.13,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-08",9,8.2,1894.42,,0.004,0.001,763.355,0.059,0.09,0.0297,12845.98,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-09",13,12.55,3160.35,,0.006,0.001,1254.375,0.059,0.111,0.0215,21110.035,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-10",24,24,6266,,0.013,0.001,2477.3,0.059,0.136,0.0065,41688.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-11",24,24,6288,,0.013,0.001,2485.8,0.059,0.139,0.0067,41829.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-12",5,4.98,1325.56,,0.003,0.001,520.906,0.059,0.042,0.01,8764.808,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-16",9,8.45,2080.97,,0.004,0.001,829.155,0.059,0.093,0.0293,13949.716,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-17",9,8.23,2009.78,,0.004,0.001,801.075,0.059,0.083,0.0258,13478.309,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-18",13,12.38,3033.5,,0.006,0.001,1210.696,0.059,0.11,0.0232,20373.34,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-19",10,9.52,2460.65,,0.005,0.001,983.674,0.059,0.107,0.0274,16552.964,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-20",7,6.05,1474.05,,0.003,0.001,598.805,0.059,0.081,0.0349,10078.075,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-21",8,7.8,1803.8,,0.004,0.001,735.8,0.059,0.093,0.0255,12380.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-22",13,11.79,3108.43,,0.006,0.001,1242.653,0.059,0.111,0.0229,20912.103,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-23",24,24,6298,,0.013,0.001,2503,0.059,0.137,0.0065,42119.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-24",24,24,6078,,0.012,0.001,2448.5,0.059,0.141,0.0068,41200.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-25",14,12.95,3336.95,,0.007,0.001,1337.635,0.059,0.109,0.0201,22508.175,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-26",24,24,6524,,0.013,0.001,2622,0.059,0.132,0.006,44117.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-27",24,24,6701,,0.014,0.001,2678.7,0.059,0.135,0.006,45071.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-28",24,24,6236,,0.013,0.001,2503.1,0.059,0.126,0.006,42121,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-29",24,24,5920,,0.012,0.001,2375.9,0.059,0.12,0.006,39979.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-06-30",24,24,5923,,0.012,0.001,2387,0.059,0.12,0.006,40165.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-01",24,24,6408,,0.013,0.001,2563.1,0.059,0.129,0.006,43129,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-02",23,22.72,5492.24,,0.011,0.001,2223.412,0.059,0.124,0.0069,37413.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-03",9,8.53,2292.64,,0.005,0.001,918.033,0.059,0.084,0.025,15446.021,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-04",9,7.77,1952.43,,0.004,0.0009,792.214,0.0589,0.065,0.0162,13329.844,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-05",10,9.22,2428.3,,0.005,0.001,977.417,0.059,0.101,0.0255,16446.733,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-06",9,8.03,1790.57,,0.004,0.001,734.435,0.059,0.087,0.0322,12356.553,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-08",10,9.09,1914.91,,0.004,0.001,794.181,0.059,0.091,0.0288,13364.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-09",10,8.27,2089.62,,0.004,0.001,854.471,0.059,0.097,0.038,14376.331,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-10",12,11.38,3006.04,,0.006,0.001,1205.784,0.059,0.12,0.0248,20289.683,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-11",8,6.51,1674.31,,0.003,0.0009,684.783,0.0586,0.11,0.0379,11523.002,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-12",8,6.54,1639.8,,0.003,0.001,676.323,0.059,0.096,0.0449,11381.518,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-13",13,12.37,2700.98,,0.006,0.001,1103.843,0.059,0.101,0.0223,18573.326,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-14",24,23.73,5183.99,,0.011,0.001,2119.173,0.059,0.129,0.0075,35660.754,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-15",12,11.42,2507.72,,0.005,0.001,1029.886,0.059,0.087,0.02,17332.084,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-16",13,11.93,2369.03,,0.005,0.001,985.678,0.059,0.093,0.0215,16585.402,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-17",6,5.77,1239.23,,0.003,0.001,507.932,0.059,0.036,0.009,8546.702,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-18",9,8.58,2187.88,,0.004,0.001,879.7,0.059,0.09,0.0271,14805.066,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-19",11,10.03,2130.95,,0.004,0.001,872.793,0.059,0.114,0.0263,14685.706,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-20",9,7.51,1491.47,,0.003,0.001,624.742,0.059,0.081,0.0427,10511.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-21",11,9.91,2536.7,,0.005,0.001,1014.124,0.059,0.091,0.0248,17064.069,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-22",9,8.45,2044.65,,0.004,0.001,830.76,0.059,0.079,0.0256,13977.04,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-23",14,13,3035.92,,0.006,0.001,1235.896,0.059,0.127,0.023,20794.804,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-24",9,7.66,1993.7,,0.004,0.001,803.276,0.0591,0.096,0.0427,13514.86,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-25",9,8.52,2329.48,,0.005,0.001,935.376,0.059,0.089,0.0271,15738.436,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-26",15,14.35,3871.35,,0.008,0.001,1540.79,0.059,0.131,0.0197,25930.455,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-27",24,24,6040,,0.012,0.001,2425.9,0.059,0.137,0.0067,40819.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-28",24,24,5986,,0.012,0.001,2399.4,0.059,0.137,0.0068,40373.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-29",24,24,6192,,0.013,0.001,2489.2,0.059,0.141,0.0067,41890.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-30",24,24,6078,,0.012,0.001,2446.6,0.059,0.137,0.0067,41171.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-07-31",23,22.75,5457,,0.011,0.001,2195.15,0.059,0.134,0.0075,36941.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-01",13,12.33,2827.8,,0.006,0.001,1157.411,0.059,0.101,0.0205,19474.442,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-02",12,10.9,2703.1,,0.005,0.001,1082.975,0.059,0.107,0.0248,18220.855,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-03",10,9.05,1916.34,,0.004,0.001,790.746,0.059,0.095,0.0299,13304.498,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-04",8,7.2,1715.92,,0.003,0.001,692.34,0.059,0.081,0.0308,11649.952,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-06",1,0.13,1.56,,0,0.001,1.248,0.059,0.001,0.088,21.008,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-07",7,6.34,1492.58,,0.003,0.001,607.038,0.059,0.1,0.034,10215.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-08",9,8.5,2119,,0.004,0.001,849.6,0.059,0.085,0.0283,14297.65,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-09",11,9.93,2528.79,,0.005,0.001,1018.761,0.059,0.121,0.0274,17142.481,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-10",9,8.73,2243.1,,0.005,0.001,902.786,0.059,0.098,0.0159,15193.61,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-11",11,9.83,2416.39,,0.005,0.001,974.995,0.059,0.099,0.0186,16405.106,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-12",12,11.3,3127.2,,0.006,0.001,1273.07,0.059,0.108,0.0223,21422.63,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-13",24,24,6899,,0.014,0.001,2775.9,0.059,0.152,0.0065,46711.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-14",24,24,6802,,0.014,0.001,2746.5,0.059,0.151,0.0065,46215.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-15",24,24,6614,,0.014,0.001,2697.6,0.059,0.157,0.0069,45393.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-16",24,24,6566,,0.013,0.001,2671.1,0.059,0.15,0.0067,44943.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-17",24,24,6917,,0.014,0.001,2819.8,0.059,0.157,0.0066,47450.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-18",24,24,6711,,0.014,0.001,2738.7,0.059,0.152,0.0066,46082.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-19",24,24,6103,,0.013,0.001,2496.5,0.059,0.144,0.0069,42007.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-20",24,24,4637,,0.01,0.001,1944.1,0.059,0.112,0.0069,32711.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-21",24,24,6053,,0.012,0.001,2431.1,0.059,0.136,0.0067,40906.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-22",24,24,6478,,0.013,0.001,2595.7,0.059,0.141,0.0065,43672.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-23",24,24,6105,,0.013,0.001,2476.2,0.059,0.138,0.0067,41665.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-24",24,24,6585,,0.013,0.001,2609.3,0.059,0.149,0.0068,43908,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-25",24,24,5783,,0.012,0.001,2337.2,0.059,0.136,0.0069,39324.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-26",24,24,5218,,0.011,0.001,2140.5,0.059,0.124,0.0069,36019.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-27",24,24,4888,,0.01,0.001,2035.2,0.059,0.116,0.0068,34247.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-28",24,24,5396,,0.011,0.001,2205.9,0.059,0.128,0.0069,37116.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-29",4,3.56,620.44,,0.001,0.001,266.204,0.059,0.066,0.0373,4480.539,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-30",17,15.8,3050.28,,0.006,0.001,1280.123,0.059,0.107,0.0206,21540.612,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-08-31",18,16.91,3449.5,,0.007,0.001,1428.893,0.059,0.131,0.019,24041.157,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-01",9,8.07,1575.31,,0.003,0.001,661.06,0.059,0.087,0.0302,11122.665,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-02",9,8.52,1766.92,,0.004,0.001,732.316,0.059,0.086,0.0278,12324.22,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-03",24,24,5730,,0.012,0.001,2312.1,0.059,0.134,0.0069,38907.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-04",24,24,6308,,0.013,0.001,2539,0.059,0.148,0.0069,42722.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-05",24,24,5786,,0.012,0.001,2333.6,0.059,0.134,0.0068,39266.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-06",24,24,5337,,0.011,0.001,2180.4,0.059,0.125,0.0068,36685.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-07",24,24,5147,,0.011,0.001,2116.1,0.059,0.124,0.007,35606,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-08",23,22.98,4993.6,,0.01,0.001,2042.352,0.059,0.123,0.0073,34369.036,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-14",10,9.25,2471,,0.005,0.001,1010.45,0.059,0.125,0.0337,17002.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-15",24,24,6293,,0.013,0.001,2516.3,0.059,0.145,0.0068,42339.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-16",24,24,6104,,0.012,0.001,2447.9,0.059,0.143,0.0069,41195.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-17",24,24,6488,,0.013,0.001,2597.4,0.059,0.148,0.0068,43704.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-18",24,24,6301,,0.013,0.001,2536.4,0.059,0.143,0.0067,42680.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-19",24,24,6193,,0.013,0.001,2505.2,0.059,0.141,0.0067,42155.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-20",24,24,5974,,0.012,0.001,2413.1,0.059,0.138,0.0068,40605.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-21",24,24,6111,,0.012,0.001,2432.7,0.059,0.138,0.0068,40937.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-22",24,24,6561,,0.013,0.001,2645.8,0.059,0.153,0.0069,44516.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-23",23,22.75,5017,,0.01,0.001,2049.75,0.059,0.128,0.0077,34488.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-28",15,14.68,3687.44,,0.008,0.001,1509.12,0.059,0.131,0.0206,25393.396,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-29",24,24,5499,,0.011,0.001,2265.7,0.059,0.128,0.0068,38121.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-09-30",24,24,6053,,0.012,0.001,2453.6,0.059,0.138,0.0067,41281.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-01",24,24,3531,,0.012,0.001,2393.4,0.059,0.135,0.0067,40272.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-02",23,23,3269,,0.011,0.001,2237.3,0.059,0.136,0.0073,37645.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-03",12,12,1723,,0.006,0.001,1193.6,0.059,0.164,0.0276,20082.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-04",15,15,1810,,0.007,0.001,1307.8,0.0591,0.133,0.0183,22004.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-05",24,24,3640,,0.013,0.001,2535.2,0.059,0.147,0.0069,42658.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-06",24,24,3933,,0.014,0.001,2706.5,0.059,0.155,0.0068,45543,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-07",24,24,3878,,0.013,0.001,2542.5,0.059,0.145,0.0066,42780.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-10",10,10,1281,,0.005,0.001,920.7,0.059,0.142,0.0269,15496.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-11",24,24,3245,,0.012,0.001,2292.8,0.059,0.165,0.0086,38576.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-12",24,24,3420,,0.012,0.001,2373.3,0.059,0.133,0.0067,39939.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-13",24,24,3504,,0.012,0.001,2378.1,0.059,0.135,0.0068,40018.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-14",19,19,2881,,0.01,0.001,1973.3,0.059,0.113,0.0068,33206.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-15",24,24,4062,,0.014,0.001,2757.8,0.059,0.16,0.0069,46408.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-16",24,24,3363,,0.012,0.001,2347.6,0.059,0.134,0.0068,39506.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-17",24,24,3280,,0.012,0.001,2282.9,0.059,0.132,0.0069,38415,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-18",19,19,2908,,0.01,0.001,1983.3,0.059,0.207,0.0199,33374.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-19",24,24,3874,,0.013,0.001,2641.4,0.059,0.168,0.0078,44445.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-20",9,9,1321,,0.005,0.001,927.9,0.059,0.15,0.0312,15615.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-21",24,24,3833,,0.013,0.001,2600.1,0.059,0.148,0.0068,43753.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-22",24,24,3789,,0.013,0.001,2550.7,0.059,0.144,0.0067,42920.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-23",24,24,3889,,0.013,0.001,2601.3,0.059,0.146,0.0067,43772,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-24",24,24,3956,,0.013,0.001,2666.2,0.059,0.145,0.0065,44859.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-25",24,24,3985,,0.014,0.001,2749.1,0.059,0.152,0.0066,46258.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-26",24,24,3898,,0.013,0.001,2651.3,0.059,0.152,0.0068,44613,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-27",24,24,3879,,0.013,0.001,2654,0.059,0.155,0.007,44660,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-28",24,24,3838,,0.013,0.001,2598.9,0.059,0.151,0.0069,43732.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-29",24,24,3914,,0.013,0.001,2592.7,0.059,0.152,0.007,43624.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-30",24,24,3872,,0.013,0.001,2579.1,0.059,0.147,0.0068,43395.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-10-31",24,24,3856,,0.013,0.001,2562.6,0.059,0.147,0.0068,43122.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-01",24,24,3849,,0.013,0.001,2585,0.059,0.143,0.0066,43496.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-02",24,24,4115,,0.015,0.001,2881,0.059,0.167,0.0069,48477.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-03",24,24,4125,,0.014,0.001,2854.9,0.059,0.151,0.0063,48037.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-04",24,24,4756,,0.014,0.001,2785.2,0.059,0.162,0.0069,46868.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-05",24,24,6072,,0.015,0.001,2888.3,0.059,0.17,0.007,48599.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-06",24,24,5493,,0.013,0.001,2551,0.059,0.145,0.0068,42924.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-07",24,24,4837,,0.011,0.001,2208.9,0.059,0.128,0.0069,37171.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-08",24,24,4994,,0.011,0.001,2260.9,0.059,0.13,0.0068,38046.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-09",24,24,5603,,0.013,0.001,2490.9,0.059,0.145,0.0069,41910.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-10",24,24,5499,,0.012,0.001,2430.4,0.059,0.135,0.0066,40901.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-11",19,19,4230,,0.01,0.001,1887.5,0.059,0.198,0.0185,31764.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-12",24,24,5102,,0.012,0.001,2327,0.059,0.135,0.0069,39154.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-13",18,18,3919,,0.009,0.001,1786.9,0.059,0.191,0.0195,30067.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-14",19,19,3705,,0.009,0.001,1712.2,0.059,0.202,0.0207,28808,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-15",14,14,3157,,0.007,0.001,1423.3,0.059,0.164,0.0191,23948.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-16",24,24,5444,,0.012,0.001,2424.6,0.059,0.141,0.0069,40801.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-17",24,24,5917,,0.013,0.001,2623.2,0.059,0.147,0.0066,44147.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-18",24,24,5848,,0.013,0.001,2607.2,0.059,0.147,0.0067,43871.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-19",24,24,4977,,0.011,0.001,2246.7,0.0593,0.14,0.0073,37800.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-24",1,0.17,2.04,,0,0.001,2.431,0.059,0.003,0.127,40.936,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-25",20,19.4,4719.8,,0.01,0.001,2071.28,0.059,0.173,0.0175,34854.96,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-26",24,24,5528,,0.012,0.001,2423.8,0.059,0.143,0.007,40786.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-27",24,24,5633,,0.012,0.001,2464.8,0.059,0.145,0.007,41474.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-28",24,24,5831,,0.013,0.001,2524,0.059,0.149,0.007,42472.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-29",24,24,6216,,0.013,0.001,2665.3,0.059,0.157,0.007,44852.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-11-30",24,24,5800,,0.013,0.001,2535.4,0.059,0.149,0.007,42663.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-01",24,24,6369,,0.014,0.001,2745.6,0.059,0.162,0.007,46197.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-02",24,24,6294,,0.014,0.001,2720,0.059,0.16,0.007,45768.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-03",24,24,6410,,0.014,0.001,2776.6,0.059,0.164,0.007,46720.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-04",24,24,6180,,0.014,0.001,2725.1,0.059,0.16,0.007,45852.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-05",24,24,6129,,0.014,0.001,2674.7,0.059,0.158,0.007,45005.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-06",24,24,5829,,0.013,0.001,2565.1,0.059,0.151,0.007,43161.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-07",24,24,5200,,0.012,0.001,2369,0.059,0.14,0.007,39861.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-08",24,24,6162,,0.014,0.001,2700.7,0.059,0.159,0.007,45445,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-09",24,24,5997,,0.013,0.001,2618.7,0.059,0.154,0.007,44062.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-10",24,24,6363,,0.014,0.001,2784.2,0.059,0.164,0.007,46850.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-11",24,24,6335,,0.014,0.001,2758.9,0.059,0.162,0.007,46420.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-12",24,24,6265,,0.014,0.001,2726.7,0.059,0.161,0.007,45881.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-13",24,24,6138,,0.014,0.001,2701.1,0.059,0.158,0.007,45450.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-14",24,24,6380,,0.014,0.001,2779.8,0.059,0.164,0.007,46776.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-15",24,24,6380,,0.014,0.001,2790.9,0.059,0.164,0.007,46963.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-16",24,24,6548,,0.014,0.001,2838.1,0.059,0.167,0.007,47758.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-17",24,24,5690,,0.013,0.001,2482.7,0.059,0.146,0.007,41772.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-18",24,24,5470,,0.012,0.001,2427.5,0.059,0.143,0.007,40844.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-19",24,24,5723,,0.013,0.001,2503.6,0.059,0.147,0.007,42128.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-20",17,15.93,3817.43,,0.009,0.001,1694.349,0.059,0.143,0.0171,28508.233,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-21",24,24,6348,,0.014,0.001,2762.8,0.059,0.162,0.007,46484.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-22",24,24,5930,,0.013,0.001,2596.4,0.059,0.153,0.007,43690,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-23",24,24,6057,,0.014,0.001,2680.2,0.059,0.158,0.007,45098.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-24",24,24,6283,,0.014,0.001,2792.8,0.059,0.164,0.007,46990.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-25",24,24,5699,,0.013,0.001,2559.4,0.059,0.151,0.007,43065.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-26",24,24,5860,,0.014,0.001,2675.1,0.059,0.158,0.007,45014.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-27",24,24,6154,,0.014,0.001,2828,0.059,0.166,0.007,47584.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-28",24,24,6276,,0.014,0.001,2866.1,0.059,0.169,0.007,48226.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-29",24,24,6244,,0.014,0.001,2761.3,0.059,0.163,0.007,46467.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-30",24,24,5715,,0.013,0.001,2557.5,0.059,0.15,0.007,43036.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X724",,"2020-12-31",9,8.72,2278.84,,0.005,0.001,1024.164,0.059,0.07,0.0091,17232.868,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-01",13,12.15,2199.6,,0.005,0.001,939.455,0.059,0.1,0.0212,15807.62,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-02",24,24,5278,,0.011,0.001,2159.4,0.059,0.115,0.0063,36337.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-03",24,24,4952,,0.01,0.001,2057.4,0.059,0.12,0.007,34619.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-04",1,0.95,209.95,,0,0.001,86.26,0.059,0.01,0.014,1450.84,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-05",9,8.65,2079.4,,0.004,0.001,839.47,0.059,0.098,0.0269,14123.86,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-06",24,24,5132,,0.011,0.001,2117.3,0.059,0.12,0.0068,35627.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-07",18,17.22,3474.34,,0.007,0.001,1450.949,0.059,0.126,0.0176,24415.317,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-08",10,9.77,1993.52,,0.004,0.001,829.204,0.059,0.054,0.0082,13954.05,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-09",9,8.47,2375.73,,0.005,0.001,964.866,0.059,0.101,0.0252,16234.72,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-10",24,24,6075,,0.012,0.001,2460.8,0.059,0.129,0.0062,41408.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-11",10,9.2,1821.24,,0.004,0.001,765.02,0.059,0.115,0.029,12871.712,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-12",19,18.2,3447.31,,0.007,0.001,1457.736,0.059,0.119,0.0153,24530.146,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-13",24,24,5344,,0.011,0.001,2188.5,0.059,0.126,0.0068,36828.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-14",24,24,5030,,0.011,0.001,2089.1,0.059,0.118,0.0067,35153.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-15",24,23.65,5313.45,,0.011,0.001,2174.465,0.059,0.131,0.0074,36586.965,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-16",8,7.07,1477.91,,0.003,0.001,611.779,0.059,0.045,0.0084,10294.345,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-17",24,24,5151,,0.011,0.001,2125.2,0.059,0.125,0.007,35759.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-18",24,24,4843,,0.01,0.001,2024.2,0.059,0.118,0.007,34059.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-19",24,24,5303,,0.011,0.001,2173.8,0.059,0.125,0.0068,36573.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-20",24,24,5738,,0.012,0.001,2332.6,0.059,0.135,0.0069,39244.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-21",24,24,4613,,0.01,0.001,1946,0.059,0.115,0.007,32744.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-22",24,24,4569,,0.01,0.001,1932.6,0.059,0.113,0.007,32516.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-23",9,8.7,1806.2,,0.004,0.001,752.62,0.059,0.048,0.0082,12664.07,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-25",6,5.72,1134.32,,0.002,0.001,476.116,0.059,0.072,0.0337,8012.224,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-26",10,8.75,1549.4,,0.003,0.001,666.031,0.059,0.089,0.0283,11208.167,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-29",8,7.53,1998.03,,0.004,0.001,817.026,0.059,0.098,0.0351,13749.939,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-30",24,23.77,5837.2,,0.012,0.001,2378.369,0.059,0.14,0.0073,40021.833,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-01-31",8,6.74,1275.38,,0.003,0.001,539.859,0.059,0.09,0.0215,9084.235,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-01",8,7.4,1608.7,,0.003,0.001,667.43,0.059,0.053,0.0124,11230.91,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-02",8,7.8,1830,,0.004,0.001,748.7,0.059,0.061,0.0124,12597.82,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-03",18,17.58,3970.63,,0.008,0.001,1624.715,0.059,0.135,0.0142,27341.413,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-04",18,17.28,3790.1,,0.008,0.001,1558.813,0.0591,0.131,0.0173,26228.39,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-05",19,17.5,3904.16,,0.008,0.001,1601.374,0.0591,0.129,0.0155,26944.04,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-06",10,8.78,1594.57,,0.003,0.001,680.782,0.059,0.093,0.0285,11455.557,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-07",9,8.25,1483.61,,0.003,0.001,634.216,0.059,0.083,0.0291,10670.859,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-09",6,5.37,1223.61,,0.003,0.001,499.539,0.059,0.09,0.0423,8405.602,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-10",16,14.82,2698.82,,0.006,0.001,1149.937,0.059,0.126,0.0221,19348.043,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-11",7,6.43,1458.24,,0.003,0.001,602.029,0.059,0.114,0.0449,10130.168,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-12",8,7.4,1697.48,,0.004,0.001,693.44,0.059,0.089,0.0241,11666.892,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-13",2,1.1,185.5,,0,0.001,80.06,0.059,0.008,0.0425,1346.39,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-14",9,8.45,2257.35,,0.005,0.001,927.085,0.059,0.086,0.0229,15600.685,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-15",24,24,4789,,0.01,0.001,2004.6,0.059,0.117,0.0069,33731.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-16",9,8.07,1580.75,,0.003,0.001,663.84,0.059,0.095,0.0299,11170.336,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-17",17,16.3,3417.22,,0.007,0.001,1412.768,0.059,0.13,0.0163,23773.888,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-18",9,8.97,1727.93,,0.004,0.001,726.919,0.059,0.051,0.0084,12229.716,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-19",9,8.73,1966.92,,0.004,0.001,802.106,0.059,0.087,0.0218,13496.694,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-20",24,24,5213,,0.011,0.001,2157.8,0.059,0.124,0.0068,36309.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-21",16,15.78,3050.8,,0.006,0.001,1286.222,0.059,0.13,0.0138,21643.212,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-22",17,16,2971,,0.006,0.001,1261,0.059,0.129,0.0195,21220.775,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-24",7,6.3,1363.4,,0.003,0.001,561.92,0.0591,0.097,0.0394,9454.15,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-25",24,24,5720,,0.012,0.001,2347.4,0.059,0.134,0.0068,39496.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-26",19,18.35,3652.49,,0.008,0.001,1532.424,0.059,0.131,0.0123,25789.117,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-27",17,15.75,2961.9,,0.006,0.001,1255.839,0.059,0.115,0.0112,21132.123,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-28",24,23.72,4482.04,,0.01,0.001,1896.364,0.059,0.103,0.0067,31911.22,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-02-29",4,3.38,562.18,,0.001,0.001,245.726,0.059,0.092,0.0698,4133.344,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-01",9,8.22,1628.41,,0.003,0.001,681.917,0.059,0.082,0.0276,11473.258,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-02",11,10.2,1926.01,,0.004,0.001,814.399,0.059,0.104,0.026,13707.036,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-03",24,23.7,4888.2,,0.01,0.001,2030.96,0.059,0.122,0.0074,34175.43,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-08",2,0.28,6.14,,0,0.001,5.882,0.0595,0.007,0.0815,98.865,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-09",20,19.6,4775.2,,0.01,0.001,1926.5,0.059,0.183,0.0178,32419.16,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-10",24,24,5796,,0.012,0.001,2346.8,0.059,0.133,0.0068,39487.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-11",24,24,5365,,0.011,0.001,2199.1,0.059,0.129,0.007,37006.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-12",24,24,6188,,0.013,0.001,2500.9,0.059,0.147,0.007,42086.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-13",24,24,5822,,0.012,0.001,2349.4,0.059,0.137,0.0069,39530.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-14",16,15.18,3511.44,,0.007,0.001,1449.554,0.059,0.125,0.0149,24394.618,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-15",8,7.8,1478.6,,0.003,0.001,624.28,0.059,0.039,0.0078,10505.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-16",14,13.33,3361.15,,0.007,0.001,1358.68,0.059,0.127,0.0203,22860.881,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-17",24,24,4804,,0.01,0.001,2009.1,0.059,0.117,0.0069,33805.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-18",24,24,4734,,0.01,0.001,1987.7,0.059,0.117,0.007,33446.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-19",24,24,4790,,0.01,0.001,2011.1,0.059,0.117,0.0069,33834.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-20",24,24,4565,,0.01,0.001,1934.4,0.059,0.114,0.007,32551.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-21",24,24,4552,,0.01,0.001,1928.5,0.059,0.112,0.0069,32450.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-22",17,16.18,3241.15,,0.007,0.001,1360.606,0.059,0.12,0.0184,22890.662,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-23",18,16.95,3150.99,,0.007,0.001,1344.94,0.059,0.114,0.0159,22629.625,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-24",24,24,4579,,0.01,0.001,1941.3,0.059,0.1,0.0061,32664.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-25",18,17.1,3201.9,,0.007,0.001,1359.635,0.059,0.114,0.0171,22879.45,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-26",11,10.12,1837.19,,0.004,0.001,785.904,0.059,0.09,0.0254,13224.937,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-27",15,14.38,2683.03,,0.006,0.001,1140.488,0.059,0.109,0.0191,19189.241,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-28",23,22.42,4982.12,,0.01,0.001,2065.662,0.059,0.127,0.0082,34759.918,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-29",7,6.53,1333.22,,0.003,0.001,561.178,0.059,0.078,0.0329,9440.91,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-30",17,15.96,2992.4,,0.006,0.001,1274.552,0.059,0.122,0.0189,21447.38,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-03-31",24,24,4520,,0.01,0.001,1917.2,0.059,0.113,0.007,32258.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-01",24,24,4659,,0.01,0.001,1962.4,0.059,0.114,0.0069,33020.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-02",24,24,6102,,0.012,0.001,2472.6,0.059,0.143,0.0069,41606.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-03",24,24,5538,,0.011,0.001,2255,0.059,0.135,0.0071,37946.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-04",24,24,5407,,0.011,0.001,2226.4,0.059,0.124,0.0066,37462.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-05",24,24,4958,,0.01,0.001,2061.4,0.059,0.121,0.007,34685,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-06",24,24,4734,,0.01,0.001,1989.1,0.059,0.117,0.007,33465.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-07",24,24,4584,,0.01,0.001,1936.9,0.059,0.112,0.0069,32592.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-08",24,24,5023,,0.01,0.001,2076.4,0.059,0.123,0.007,34935.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-09",24,24,5419,,0.011,0.001,2215.5,0.059,0.128,0.0069,37283,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-10",24,24,6720,,0.014,0.001,2697.7,0.059,0.159,0.007,45396.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-11",24,24,6370,,0.013,0.001,2556.2,0.059,0.144,0.0067,43009.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-12",24,24,6612,,0.013,0.001,2630.7,0.059,0.134,0.006,44266.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-13",24,24,6470,,0.013,0.001,2584.5,0.059,0.135,0.0062,43489,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-14",24,24,6221,,0.013,0.001,2518.4,0.059,0.142,0.0067,42375,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-15",24,24,6332,,0.013,0.001,2547,0.059,0.142,0.0066,42859.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-16",24,24,6532,,0.013,0.001,2654.3,0.059,0.153,0.0068,44667.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-17",24,24,6202,,0.013,0.001,2503.9,0.059,0.134,0.0064,42137,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-18",24,24,6003,,0.012,0.001,2435.4,0.059,0.125,0.0061,40983.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-19",24,24,5917,,0.012,0.001,2410.5,0.059,0.129,0.0064,40560.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-20",24,24,6148,,0.013,0.001,2512.3,0.059,0.143,0.0068,42274.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-21",24,24,5616,,0.012,0.001,2309.4,0.059,0.133,0.0069,38857.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-22",24,24,6253,,0.013,0.001,2524.8,0.059,0.139,0.0065,42481.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-23",24,24,5692,,0.012,0.001,2324.6,0.059,0.124,0.0063,39113.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-24",24,24,6460,,0.013,0.001,2585.4,0.059,0.149,0.0068,43502.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-25",24,24,6730,,0.014,0.001,2715.8,0.059,0.156,0.0068,45698.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-26",24,24,5854,,0.012,0.001,2394.8,0.059,0.137,0.0068,40293.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-27",24,24,5671,,0.012,0.001,2319.6,0.059,0.134,0.0069,39027.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-28",24,24,6614,,0.013,0.001,2670.1,0.059,0.151,0.0067,44929,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-29",24,24,6589,,0.013,0.001,2658.4,0.059,0.154,0.0069,44734.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-04-30",24,24,5689,,0.012,0.001,2298.8,0.059,0.133,0.0069,38680.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-01",24,24,5964,,0.012,0.001,2418,0.059,0.138,0.0068,40689.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-02",24,24,5664,,0.012,0.001,2320.5,0.059,0.133,0.0068,39047.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-03",24,24,5642,,0.012,0.001,2315.3,0.059,0.134,0.0069,38956.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-04",24,24,6825,,0.014,0.001,2747.6,0.059,0.161,0.007,46234.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-05",24,24,6722,,0.014,0.001,2700.4,0.059,0.156,0.0068,45440.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-06",24,24,5969,,0.012,0.001,2416.6,0.059,0.143,0.007,40665.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-07",24,24,6672,,0.014,0.001,2690.6,0.059,0.155,0.0068,45278.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-08",24,24,6656,,0.014,0.001,2675,0.059,0.154,0.0068,45011.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-09",24,24,6704,,0.014,0.001,2694.2,0.059,0.151,0.0067,45332.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-10",24,24,5897,,0.012,0.001,2387.5,0.059,0.126,0.0063,40173.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-11",14,13.27,3710.62,,0.008,0.001,1492.935,0.059,0.09,0.0089,25118.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-20",5,4.18,818.2,,0.002,0.001,343.956,0.059,0.07,0.0436,5788.344,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-21",2,1.98,347.7,,0.001,0.001,149.07,0.059,0.015,0.0125,2508.45,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-26",12,11.13,3060.64,,0.006,0.001,1264.521,0.0591,0.127,0.0208,21282.385,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-27",24,24,6153,,0.013,0.001,2523.5,0.059,0.145,0.0068,42462.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-28",24,24,6751,,0.014,0.001,2738.8,0.059,0.155,0.0067,46083.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-29",24,24,6777,,0.014,0.001,2770.4,0.059,0.159,0.0068,46614.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-30",24,24,6706,,0.014,0.001,2713.1,0.059,0.16,0.007,45656.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-05-31",24,24,6736,,0.014,0.001,2712.3,0.059,0.158,0.0069,45638.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-01",24,24,6816,,0.014,0.001,2750.2,0.059,0.16,0.0069,46277.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-02",24,24,6463,,0.013,0.001,2624,0.059,0.151,0.0068,44153,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-03",24,24,6241,,0.013,0.001,2523.5,0.059,0.146,0.0069,42462.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-04",17,16.13,3535.55,,0.007,0.001,1446.921,0.059,0.144,0.0187,24344.281,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-05",24,24,5677,,0.012,0.001,2293.4,0.059,0.13,0.0068,38593.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-06",24,24,5787,,0.012,0.001,2344.6,0.059,0.135,0.0068,39449.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-07",24,24,6212,,0.013,0.001,2521.4,0.059,0.146,0.0069,42425.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-08",24,24,6468,,0.013,0.001,2593.9,0.059,0.145,0.0066,43648.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-09",24,24,6524,,0.013,0.001,2604.7,0.059,0.141,0.0065,43828.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-10",24,24,6279,,0.013,0.001,2498.6,0.059,0.142,0.0068,42043.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-11",24,24,6292,,0.013,0.001,2503.9,0.059,0.147,0.007,42131.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-12",24,24,6697,,0.014,0.001,2708.4,0.059,0.159,0.007,45574.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-13",24,24,5915,,0.012,0.001,2416.6,0.059,0.14,0.0069,40664.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-14",24,24,5674,,0.012,0.001,2325.5,0.059,0.135,0.0069,39128.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-15",24,24,6262,,0.013,0.001,2536,0.059,0.145,0.0068,42673.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-16",24,24,6027,,0.012,0.001,2439,0.059,0.142,0.0069,41039.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-17",24,24,5746,,0.012,0.001,2328,0.059,0.13,0.0067,39174.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-18",24,24,5907,,0.012,0.001,2378.1,0.059,0.133,0.0067,40020.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-19",24,24,6659,,0.014,0.001,2678,0.059,0.145,0.0065,45060.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-20",24,24,6329,,0.013,0.001,2545.4,0.059,0.136,0.0064,42836.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-21",24,24,5646,,0.012,0.001,2304.4,0.059,0.131,0.0068,38778.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-22",24,24,6655,,0.014,0.001,2698,0.059,0.154,0.0068,45398.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-23",24,24,6403,,0.013,0.001,2600.1,0.059,0.15,0.0069,43751.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-24",24,24,6092,,0.013,0.001,2479.4,0.059,0.143,0.0069,41724.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-25",24,24,6474,,0.013,0.001,2626.5,0.059,0.151,0.0068,44199.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-26",23,22.8,6173,,0.013,0.001,2519.96,0.059,0.154,0.0074,42398.36,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-06-30",1,0.15,2.55,,0,0.001,2.19,0.059,0.002,0.097,36.855,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-02",8,7.55,2012.75,,0.004,0.001,821.325,0.059,0.108,0.0328,13821.44,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-03",24,24,6500,,0.013,0.001,2614.2,0.059,0.148,0.0068,43991.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-04",24,24,6479,,0.013,0.001,2612.2,0.059,0.152,0.0069,43962.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-05",24,24,6565,,0.013,0.001,2640.5,0.059,0.15,0.0068,44431.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-06",24,24,6281,,0.013,0.001,2536.7,0.059,0.145,0.0068,42685.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-07",24,24,6206,,0.013,0.001,2516.2,0.059,0.148,0.007,42345.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-08",24,24,5861,,0.012,0.001,2372,0.059,0.139,0.007,39914.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-09",24,24,6262,,0.013,0.001,2531.8,0.059,0.131,0.0062,42599.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-10",24,24,6214,,0.013,0.001,2515,0.059,0.144,0.0068,42320.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-11",24,24,6470,,0.013,0.001,2633,0.059,0.15,0.0068,44303.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-12",24,24,6642,,0.014,0.001,2696.8,0.059,0.155,0.0068,45384.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-13",24,24,6094,,0.013,0.001,2499.8,0.059,0.143,0.0068,42064.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-14",24,24,5324,,0.011,0.001,2189.4,0.059,0.128,0.0069,36841.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-15",24,24,6136,,0.013,0.001,2495,0.059,0.146,0.0069,41981.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-16",24,24,5911,,0.012,0.001,2414,0.059,0.141,0.007,40619,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-17",24,24,6429,,0.013,0.001,2594.5,0.059,0.152,0.007,43661.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-18",24,24,6469,,0.013,0.001,2615.3,0.059,0.149,0.0068,44006.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-19",24,24,5849,,0.012,0.001,2373.6,0.059,0.132,0.0066,39938.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-20",24,24,5835,,0.012,0.001,2372.1,0.059,0.135,0.0068,39913.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-21",24,24,6595,,0.013,0.001,2642.5,0.059,0.15,0.0068,44462.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-22",24,24,6147,,0.013,0.001,2501.4,0.059,0.142,0.0067,42091.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-23",24,24,5767,,0.012,0.001,2358.3,0.059,0.134,0.0068,39684.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-24",24,24,6140,,0.013,0.001,2491.2,0.059,0.144,0.0069,41915.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-25",24,24,6582,,0.013,0.001,2658.8,0.059,0.154,0.0069,44739.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-26",24,24,6738,,0.014,0.001,2704.4,0.059,0.156,0.0068,45510.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-27",24,24,6050,,0.012,0.001,2453.5,0.059,0.129,0.0063,41289,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-28",24,24,5989,,0.012,0.001,2422.2,0.059,0.137,0.0067,40760.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-29",24,24,6178,,0.013,0.001,2503.7,0.059,0.144,0.0068,42127.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-30",24,24,6093,,0.013,0.001,2480.2,0.059,0.138,0.0066,41733.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-07-31",24,24,5846,,0.012,0.001,2367.4,0.059,0.134,0.0068,39828.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-01",24,24,5606,,0.012,0.001,2316.8,0.059,0.133,0.0068,38981.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-02",24,24,5937,,0.012,0.001,2439,0.059,0.141,0.0069,41039.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-03",24,24,5829,,0.012,0.001,2381.3,0.059,0.135,0.0068,40073.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-04",24,24,6574,,0.013,0.001,2664.8,0.059,0.154,0.0069,44840.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-05",24,24,5856,,0.012,0.001,2357.9,0.059,0.13,0.0065,39674.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-06",24,24,5773,,0.012,0.001,2332.2,0.059,0.134,0.0068,39243.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-07",24,24,5914,,0.012,0.001,2410.9,0.059,0.138,0.0068,40565.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-08",24,24,6245,,0.013,0.001,2525.9,0.059,0.146,0.0069,42503.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-09",24,24,6359,,0.013,0.001,2587.8,0.059,0.15,0.0069,43547.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-10",24,24,6658,,0.014,0.001,2693.2,0.059,0.154,0.0068,45316.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-11",24,24,6575,,0.013,0.001,2663.6,0.059,0.154,0.0069,44817.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-12",24,24,6703,,0.014,0.001,2729.1,0.059,0.16,0.007,45922.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-13",24,24,6861,,0.014,0.001,2794.1,0.059,0.161,0.0068,47022.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-14",24,24,6770,,0.014,0.001,2768,0.059,0.163,0.007,46575.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-15",24,24,6606,,0.014,0.001,2728.7,0.059,0.159,0.0069,45919.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-16",24,24,6540,,0.014,0.001,2690.6,0.059,0.156,0.0069,45277.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-17",24,24,6885,,0.014,0.001,2847.9,0.059,0.166,0.0069,47920.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-18",24,24,6702,,0.014,0.001,2769.1,0.059,0.162,0.007,46595.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-19",24,24,5986,,0.012,0.001,2463.6,0.059,0.141,0.0068,41457.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-20",24,24,4653,,0.01,0.001,1958.7,0.059,0.113,0.0068,32959.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-21",24,24,6094,,0.012,0.001,2466.9,0.059,0.143,0.0069,41511,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-22",24,24,6496,,0.013,0.001,2633,0.059,0.15,0.0068,44306.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-23",24,24,6117,,0.013,0.001,2512.3,0.059,0.146,0.0069,42272.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-24",24,24,6714,,0.014,0.001,2729.2,0.059,0.157,0.0068,45928,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-25",24,24,5804,,0.012,0.001,2362.8,0.059,0.132,0.0067,39760.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-26",24,24,5237,,0.011,0.001,2161.4,0.059,0.125,0.0069,36369.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-27",24,24,4897,,0.01,0.001,2047.9,0.059,0.118,0.0068,34458.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-28",24,24,5400,,0.011,0.001,2222.2,0.059,0.128,0.0069,37393.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-29",24,24,6174,,0.013,0.001,2520.7,0.059,0.146,0.0069,42419.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-30",24,24,5110,,0.011,0.001,2126.1,0.059,0.124,0.0069,35775.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-08-31",24,24,5417,,0.011,0.001,2233.1,0.059,0.128,0.0068,37578.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-01",24,24,6194,,0.013,0.001,2524.1,0.059,0.147,0.0069,42472,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-02",24,24,5522,,0.011,0.001,2263.7,0.059,0.131,0.0069,38089.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-03",24,24,5744,,0.012,0.001,2333.8,0.059,0.135,0.0069,39272.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-04",24,24,6306,,0.013,0.001,2561.7,0.059,0.149,0.0069,43104.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-05",24,24,5918,,0.012,0.001,2436.9,0.059,0.141,0.0069,41003.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-06",24,24,5390,,0.011,0.001,2223.5,0.059,0.129,0.0069,37421.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-07",24,24,5196,,0.011,0.001,2155,0.059,0.124,0.0068,36263.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-08",24,24,5381,,0.011,0.001,2229.3,0.059,0.128,0.0068,37511.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-09",24,24,5558,,0.011,0.001,2258,0.059,0.13,0.0069,37996.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-10",24,24,5956,,0.012,0.001,2437.4,0.059,0.14,0.0068,41012.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-11",24,24,6448,,0.013,0.001,2623.5,0.059,0.148,0.0067,44143.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-12",24,24,6112,,0.013,0.001,2503.4,0.059,0.142,0.0068,42127,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-13",24,24,5992,,0.012,0.001,2473.5,0.059,0.14,0.0067,41620.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-14",24,24,6280,,0.013,0.001,2563.3,0.059,0.149,0.0069,43135.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-15",24,24,6314,,0.013,0.001,2562.6,0.059,0.149,0.0069,43122.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-16",24,24,6094,,0.012,0.001,2463.8,0.059,0.143,0.0069,41458.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-17",24,24,6573,,0.014,0.001,2687.2,0.059,0.159,0.007,45218.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-18",15,13.55,3114.08,,0.006,0.001,1277.045,0.0591,0.111,0.0181,21488.268,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-19",10,8.98,2129.01,,0.004,0.001,880.244,0.059,0.104,0.0272,14812.34,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-20",11,10.15,2370.75,,0.005,0.001,973.595,0.059,0.115,0.0269,16381.76,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-21",24,24,6108,,0.012,0.001,2454,0.059,0.144,0.007,41296.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-22",11,9.71,2251.68,,0.005,0.001,915.919,0.0591,0.109,0.0376,15413.626,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-23",24,24,5358,,0.011,0.001,2201.3,0.059,0.126,0.0068,37040.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-24",24,24,6286,,0.013,0.001,2564.5,0.059,0.142,0.0065,43149.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-25",24,24,5968,,0.012,0.001,2444.3,0.059,0.136,0.0067,41130.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-26",24,24,5537,,0.012,0.001,2281.5,0.059,0.133,0.0069,38396.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-27",24,24,6434,,0.013,0.001,2628.8,0.059,0.15,0.0068,44230.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-28",24,24,6323,,0.013,0.001,2592.5,0.059,0.149,0.0068,43624.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-29",24,24,5496,,0.012,0.001,2281.7,0.059,0.133,0.0069,38393.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-09-30",24,24,6048,,0.013,0.001,2477.3,0.059,0.145,0.007,41685.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-01",24,24,5930,,0.012,0.001,2420.4,0.059,0.142,0.007,40722.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-02",24,24,5837,,0.012,0.001,2393.8,0.059,0.138,0.0069,40279.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-03",24,24,6323,,0.013,0.001,2580,0.059,0.15,0.0069,43409.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-04",24,24,6006,,0.013,0.001,2477.7,0.059,0.141,0.0068,41690,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-05",24,24,6201,,0.013,0.001,2573.2,0.059,0.157,0.0073,43302.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-06",12,12,3090,,0.006,0.001,1279.2,0.059,0.121,0.0143,21527.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-07",24,24,6890,,0.014,0.001,2810.2,0.059,0.163,0.0069,47289.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-08",24,24,6161,,0.013,0.001,2514.5,0.059,0.143,0.0068,42309.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-09",24,24,6164,,0.013,0.001,2520.9,0.059,0.143,0.0068,42422.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-10",23,23,5680,,0.012,0.001,2348.5,0.059,0.143,0.0075,39519,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-12",9,9,1984,,0.004,0.001,831.3,0.059,0.144,0.0336,13985.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-13",24,24,5910,,0.012,0.001,2427.3,0.059,0.14,0.0069,40844.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-14",24,24,6276,,0.013,0.001,2583.8,0.059,0.151,0.007,43480,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-15",24,24,6917,,0.014,0.001,2839,0.059,0.165,0.0069,47770.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-16",24,24,5764,,0.012,0.001,2398.9,0.059,0.136,0.0068,40367.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-17",24,24,5574,,0.012,0.001,2304.5,0.059,0.133,0.0069,38778.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-18",24,24,6711,,0.014,0.001,2724.3,0.059,0.156,0.0068,45837.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-19",24,24,6617,,0.014,0.001,2707.7,0.059,0.157,0.0069,45561.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-20",24,24,6784,,0.014,0.001,2802.9,0.059,0.163,0.0069,47164.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-21",24,24,6418,,0.013,0.001,2619.1,0.059,0.151,0.0069,44071.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-22",24,24,6332,,0.013,0.001,2578.6,0.059,0.149,0.0069,43386.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-23",24,24,6483,,0.013,0.001,2633.3,0.059,0.152,0.0069,44307.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-24",10,10,2719,,0.006,0.001,1111.9,0.059,0.072,0.0083,18711,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-25",9,9,2226,,0.005,0.001,925.2,0.059,0.143,0.031,15569.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-26",24,24,6680,,0.014,0.001,2742.6,0.059,0.162,0.007,46150.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-27",24,24,6576,,0.014,0.001,2689.4,0.059,0.156,0.0069,45257.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-28",24,24,6312,,0.013,0.001,2557.5,0.059,0.148,0.0069,43038.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-29",16,16,3750,,0.008,0.001,1509.3,0.0591,0.132,0.0108,25395.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-30",24,24,6471,,0.013,0.001,2612,0.059,0.153,0.007,43951.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-10-31",8,8,2135,,0.004,0.001,863,0.059,0.065,0.0094,14522.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-05",2,0.28,7.47,,0,0.001,7.447,0.059,0.011,0.181,125.23,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-06",10,9.47,2177.32,,0.005,0.001,912.131,0.059,0.134,0.0305,15348.648,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-07",24,23.98,5451.24,,0.011,0.001,2242.968,0.059,0.13,0.0069,37740.998,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-08",24,24,5670,,0.012,0.001,2335.1,0.059,0.138,0.007,39291.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-09",24,24,6486,,0.013,0.001,2663.3,0.059,0.156,0.007,44811.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-10",24,24,6350,,0.013,0.001,2627.5,0.059,0.155,0.007,44212.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-11",24,24,6400,,0.013,0.001,2617.2,0.059,0.153,0.007,44041.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-12",24,24,5790,,0.012,0.001,2399.9,0.059,0.14,0.007,40378,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-13",24,24,6653,,0.014,0.001,2682.2,0.059,0.16,0.0071,45139.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-14",24,24,5591,,0.012,0.001,2298.1,0.059,0.133,0.0069,38671.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-15",24,24,6332,,0.013,0.001,2576.1,0.059,0.151,0.007,43350.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-16",24,24,6220,,0.013,0.001,2546.4,0.059,0.152,0.0071,42850.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-17",24,24,6632,,0.014,0.001,2679.4,0.059,0.157,0.007,45084.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-18",24,24,6558,,0.013,0.001,2671.4,0.059,0.157,0.007,44957.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-19",24,24,5957,,0.012,0.001,2429.3,0.059,0.144,0.007,40882.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-20",24,24,6949,,0.014,0.001,2814.2,0.059,0.166,0.007,47357.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-21",24,24,7106,,0.015,0.001,2902.6,0.059,0.17,0.007,48844.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-22",24,24,7210,,0.015,0.001,2945.9,0.059,0.174,0.007,49573.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-23",24,24,6791,,0.014,0.001,2796.4,0.059,0.163,0.0069,47050.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-24",24,24,6675,,0.014,0.001,2718.3,0.059,0.159,0.007,45738.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-25",24,24,6748,,0.014,0.001,2727.6,0.059,0.161,0.007,45900.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-26",24,24,6146,,0.013,0.001,2496.2,0.059,0.144,0.0069,42003.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-27",24,24,6273,,0.013,0.001,2529.2,0.059,0.147,0.0069,42560.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-28",24,24,6500,,0.013,0.001,2647,0.059,0.155,0.007,44543.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-29",24,24,6910,,0.014,0.001,2794.5,0.059,0.164,0.007,47026.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-11-30",24,24,6422,,0.013,0.001,2633.5,0.059,0.155,0.007,44313.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-01",24,24,7002,,0.014,0.001,2858.4,0.059,0.166,0.0069,48098.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-02",24,24,6992,,0.014,0.001,2847.1,0.059,0.162,0.0068,47907.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-03",24,24,7107,,0.015,0.001,2905.8,0.059,0.171,0.007,48895.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-04",24,24,6707,,0.014,0.001,2744.6,0.059,0.162,0.007,46181.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-05",24,24,6844,,0.014,0.001,2769.7,0.059,0.161,0.0069,46604.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-06",24,24,6545,,0.013,0.001,2636.6,0.059,0.155,0.007,44363,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-07",24,24,5791,,0.012,0.001,2411.3,0.059,0.142,0.007,40576.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-08",24,24,6902,,0.014,0.001,2802.8,0.059,0.164,0.007,47161.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-09",24,24,6743,,0.014,0.001,2758.2,0.059,0.161,0.0069,46411.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-10",24,24,7044,,0.014,0.001,2844.9,0.059,0.167,0.007,47871.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-11",24,24,7002,,0.014,0.001,2833.3,0.059,0.165,0.0069,47673.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-12",24,24,6941,,0.014,0.001,2812.3,0.059,0.166,0.007,47322.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-13",24,24,6804,,0.014,0.001,2768.7,0.059,0.162,0.007,46588.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-14",24,24,7016,,0.014,0.001,2830.5,0.059,0.167,0.007,47630,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-15",24,24,6986,,0.014,0.001,2828.6,0.059,0.166,0.007,47594,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-16",24,24,7159,,0.015,0.001,2914.5,0.059,0.172,0.007,49036.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-17",24,24,6376,,0.013,0.001,2603.7,0.059,0.152,0.007,43806.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-18",24,24,6049,,0.013,0.001,2508.1,0.059,0.145,0.0069,42201.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-19",24,24,6345,,0.013,0.001,2622.1,0.059,0.153,0.007,44123.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-20",24,24,6472,,0.013,0.001,2667.1,0.059,0.157,0.007,44878.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-21",24,24,6904,,0.014,0.001,2801.6,0.059,0.16,0.0068,47141.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-22",24,24,6592,,0.013,0.001,2672.6,0.059,0.157,0.007,44973.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-23",7,6.93,2023.22,,0.004,0.001,827.203,0.059,0.061,0.0091,13919.102,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-25",8,6.67,1735.94,,0.004,0.001,711.14,0.059,0.122,0.0348,11964.929,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-28",9,8.22,2314.12,,0.005,0.001,956.918,0.059,0.122,0.0307,16102.04,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-29",24,24,6780,,0.014,0.001,2754,0.059,0.161,0.007,46344.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-30",24,24,6204,,0.013,0.001,2519.4,0.059,0.147,0.0069,42395.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Los Medanos Energy Center, LLC",55217,"X725",,"2020-12-31",24,24,6366,,0.013,0.001,2566.9,0.059,0.149,0.0069,43194.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-01",3,1.44,0,,0,0.001,35.282,0.0597,0.04,0.1187,592.63,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-02",8,6.17,675.33,,0.002,0.001,465.489,0.059,0.735,0.3458,7832.932,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-03",8,7.72,688.04,,0.003,0.001,510.476,0.059,0.083,0.0256,8589.888,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-04",19,18.4,1983.2,,0.007,0.001,1379.26,0.059,0.097,0.0102,23209.79,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-05",24,24,2815,,0.01,0.001,1900.9,0.059,0.1,0.0062,31985.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-06",24,24,2903,,0.01,0.001,1944.2,0.059,0.109,0.0065,32714.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-07",24,24,2822,,0.01,0.001,1903.4,0.059,0.101,0.0062,32030.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-08",20,18.35,2182.16,,0.007,0.001,1461.214,0.0591,0.109,0.0089,24587.548,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-09",24,24,3261,,0.011,0.001,2106.3,0.059,0.123,0.007,35444,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-10",24,24,3079,,0.01,0.001,2022.6,0.059,0.114,0.0067,34030.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-11",24,24,2656,,0.009,0.001,1829.4,0.059,0.097,0.0062,30782.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-12",24,24,3259,,0.011,0.001,2101.3,0.059,0.119,0.0068,35355.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-13",24,24,3168,,0.01,0.001,2057.4,0.059,0.123,0.0072,34615.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-14",24,24,2835,,0.01,0.001,1907.8,0.059,0.101,0.0062,32103.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-15",24,24,2755,,0.009,0.001,1866.5,0.059,0.1,0.0064,31411.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-16",24,24,3224,,0.01,0.001,2077.9,0.059,0.106,0.0061,34964.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-17",24,24,2764,,0.009,0.001,1868.2,0.059,0.093,0.006,31435.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-18",24,24,3125,,0.01,0.001,2037.4,0.059,0.111,0.0065,34281.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-19",24,24,2841,,0.01,0.001,1913,0.059,0.097,0.0061,32192.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-20",24,24,2915,,0.01,0.001,1949.5,0.059,0.095,0.0057,32806.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-21",10,9.3,1166.8,,0.004,0.001,771.84,0.059,0.041,0.0059,12987.89,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-22",12,11.23,1379.21,,0.005,0.001,917.803,0.059,0.099,0.031,15445.179,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-23",16,14.62,1738.67,,0.006,0.001,1164.32,0.059,0.103,0.0214,19592.839,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-24",9,8.23,1044.02,,0.003,0.001,689.184,0.059,0.038,0.0062,11598.013,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-26",1,0.07,0,,0,0.001,1.078,0.06,0,0.051,18.095,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-27",1,0.03,0,,0,0.001,0.174,0.059,0.001,0.684,2.952,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-05",1,0.08,0,,0,0.001,1.496,0.059,0.009,0.684,25.168,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-06",10,8,799.6,,0.003,0.001,567.56,0.059,0.495,0.2779,9550.596,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-07",20,18.93,2603.43,,0.008,0.001,1677.772,0.059,0.136,0.0134,28232.037,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-08",21,20.65,3224.9,,0.01,0.001,2032.927,0.059,0.158,0.0135,34206.884,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-09",24,24,3488,,0.011,0.001,2229.7,0.059,0.13,0.0069,37516.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-10",17,16.44,2443.8,,0.008,0.001,1550.646,0.059,0.141,0.0138,26092.396,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-11",10,9.43,1397.43,,0.004,0.001,883.946,0.059,0.049,0.0066,14874.136,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-12",3,2.85,243.5,,0.001,0.001,183.7,0.059,0.068,0.0567,3092.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-13",9,8.68,1307.64,,0.004,0.001,822.464,0.059,0.046,0.0066,13839.54,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-16",8,7.7,929.6,,0.003,0.001,622.91,0.059,0.074,0.0236,10479.02,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-17",8,7.32,953.68,,0.003,0.001,621.128,0.059,0.036,0.0068,10450.256,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-24",11,10.75,1260.75,,0.004,0.001,855.725,0.059,0.083,0.0175,14401.175,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-25",8,7.18,970.7,,0.003,0.001,629.27,0.059,0.034,0.0065,10587.316,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-27",7,6.42,905.86,,0.003,0.001,584.206,0.059,0.072,0.0401,9829.994,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-28",22,20.4,2707.02,,0.009,0.001,1762.5,0.059,0.135,0.0189,29653.36,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-29",20,18.47,2248.77,,0.008,0.001,1504.024,0.059,0.122,0.0182,25307.987,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-04-30",4,3.3,371.8,,0.001,0.001,254.08,0.059,0.014,0.0065,4276.62,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-07",11,10.63,1077.83,,0.004,0.001,762.905,0.059,0.09,0.0235,12835.671,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-08",1,0.3,22.5,,0,0.001,17.91,0.059,0.001,0.006,301.29,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-26",13,12.63,1410.09,,0.005,0.001,971.787,0.059,0.094,0.0186,16353.487,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-27",24,24,2401,,0.009,0.001,1711.1,0.059,0.073,0.0048,28793.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-28",24,24,2963,,0.01,0.001,1969.8,0.059,0.105,0.0062,33146.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-29",24,24,3249,,0.011,0.001,2112.3,0.059,0.119,0.0066,35545.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-30",3,2.23,296.33,,0.001,0.001,193.516,0.059,0.011,0.0067,3256.534,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-02",21,20.2,2889.8,,0.009,0.001,1835.48,0.059,0.15,0.04,30883.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-03",24,24,3811,,0.012,0.001,2349.5,0.059,0.136,0.0069,39533.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-04",8,7.22,1000.96,,0.003,0.001,638.262,0.059,0.036,0.0065,10737.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-05",21,20.05,2305,,0.008,0.001,1559.795,0.059,0.098,0.0095,26244.775,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-06",7,6.27,908.36,,0.003,0.001,574.379,0.059,0.031,0.0061,9665.627,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-08",11,10.5,1366.5,,0.004,0.001,886.75,0.059,0.109,0.0309,14919.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-09",18,17.01,2332.15,,0.008,0.001,1491.379,0.059,0.124,0.0149,25095.47,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-10",24,24,3351,,0.011,0.001,2133.4,0.059,0.125,0.0069,35895.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-11",24,24,3424,,0.011,0.001,2178.1,0.059,0.125,0.0068,36650.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-12",2,2,260,,0.001,0.001,169.9,0.059,0.009,0.0065,2857.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-17",1,0.08,0,,0,0.001,1.504,0.059,0.001,0.101,25.312,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-18",14,13.05,1560,,0.005,0.001,1040.595,0.0591,0.068,0.0558,17508.375,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-19",24,24,3161,,0.01,0.001,2046.6,0.059,0.118,0.0068,34436.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-20",2,1.27,139.25,,0,0.001,96.081,0.059,0.005,0.0055,1616.985,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-22",15,14.2,2032.8,,0.007,0.001,1290.64,0.059,0.112,0.0253,21716.14,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-23",24,24,3200,,0.01,0.001,2062.7,0.059,0.122,0.007,34706.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-24",24,24,3299,,0.011,0.001,2111,0.059,0.118,0.0065,35521.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-25",24,24,3246,,0.01,0.001,2080,0.059,0.117,0.0066,34997.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-26",24,24,3212,,0.01,0.001,2071.2,0.059,0.11,0.0063,34849.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-27",24,24,3555,,0.011,0.001,2229.6,0.059,0.122,0.0065,37516.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-28",7,6.88,881.64,,0.003,0.001,573.528,0.059,0.029,0.006,9649.584,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-05",8,7.68,898.92,,0.003,0.001,600.256,0.059,0.086,0.0305,10099.624,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-06",23,22.32,2328.68,,0.008,0.001,1614.92,0.059,0.063,0.0046,27172.864,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-07",13,11.82,1458.04,,0.005,0.001,963.758,0.059,0.098,0.0198,16216.72,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-08",24,24,2961,,0.01,0.001,1953.2,0.059,0.102,0.006,32869.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-09",18,16.9,2361.75,,0.008,0.001,1509.659,0.059,0.109,0.0129,25402.25,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-10",24,24,3166,,0.01,0.001,2053.3,0.059,0.118,0.0068,34549,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-11",24,24,3719,,0.012,0.001,2319.2,0.059,0.125,0.0064,39026.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-12",24,24,3410,,0.011,0.001,2165.6,0.059,0.118,0.0063,36439.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-13",24,24,3476,,0.011,0.001,2192.7,0.059,0.118,0.0063,36896.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-14",24,24,2965,,0.01,0.001,1950,0.059,0.108,0.0065,32810.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-15",24,24,2773,,0.009,0.001,1865.2,0.059,0.096,0.006,31382.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-16",24,24,2889,,0.01,0.001,1920,0.059,0.104,0.0064,32308.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-17",24,24,2861,,0.01,0.001,1911.9,0.059,0.105,0.0065,32174.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-18",24,24,3121,,0.01,0.001,2036.2,0.059,0.115,0.0067,34261.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-19",7,5.63,566.25,,0.002,0.001,399.016,0.059,0.053,0.0249,6714.352,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-21",23,22.25,3003.75,,0.01,0.001,1938.8,0.059,0.149,0.0181,32620,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-22",24,24,3206,,0.01,0.001,2070.4,0.059,0.113,0.0064,34840.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-23",24,24,3258,,0.011,0.001,2090.9,0.059,0.115,0.0065,35182.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-24",5,4.5,615,,0.002,0.001,392.5,0.059,0.021,0.0064,6604.55,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-25",14,13.7,2045.9,,0.007,0.001,1290.44,0.059,0.128,0.0184,21714.64,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-26",24,24,3619,,0.011,0.001,2268.9,0.059,0.128,0.0067,38179.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-27",24,24,3340,,0.011,0.001,2127.9,0.059,0.121,0.0068,35807,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-28",24,24,3252,,0.011,0.001,2089,0.059,0.12,0.0068,35148.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-29",24,24,3035,,0.01,0.001,1997.5,0.059,0.112,0.0067,33612.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-30",24,24,3076,,0.01,0.001,2020.7,0.059,0.109,0.0063,34000.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-07-31",24,24,3129,,0.01,0.001,2045.8,0.059,0.115,0.0067,34428.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-01",24,24,3418,,0.011,0.001,2183.4,0.059,0.12,0.0064,36737.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-02",24,24,3260,,0.011,0.001,2095.1,0.059,0.097,0.0055,35255.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-03",18,16.75,2495.97,,0.008,0.001,1579.012,0.059,0.109,0.0122,26569.261,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-04",24,24,4055,,0.013,0.001,2490,0.059,0.138,0.0066,41900.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-05",24,24,3317,,0.011,0.001,2132.1,0.059,0.124,0.0069,35881.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-06",24,24,2821,,0.01,0.001,1897.8,0.059,0.106,0.0066,31933,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-07",24,24,3336,,0.011,0.001,2147.9,0.059,0.123,0.0068,36145.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-08",24,24,3735,,0.012,0.001,2337.2,0.059,0.132,0.0067,39325.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-09",24,24,3423,,0.011,0.001,2188.4,0.059,0.127,0.0069,36820.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-10",24,24,3266,,0.011,0.001,2108.5,0.059,0.119,0.0068,35473.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-11",24,24,3275,,0.011,0.001,2108.9,0.059,0.114,0.0063,35488.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-12",24,24,3638,,0.011,0.001,2270.6,0.059,0.13,0.0068,38209.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-13",24,24,3611,,0.011,0.001,2268.5,0.059,0.128,0.0067,38171.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-14",20,19.58,2852.94,,0.009,0.001,1801.419,0.059,0.127,0.0114,30310.443,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-15",24,24,3396,,0.011,0.001,2174.5,0.059,0.121,0.0065,36587.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-16",24,24,3184,,0.01,0.001,2062.4,0.059,0.111,0.0063,34703.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-17",24,24,3640,,0.012,0.001,2278.6,0.059,0.126,0.0066,38343,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-18",24,24,3253,,0.011,0.001,2083.1,0.059,0.119,0.0068,35053.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-19",24,24,3263,,0.011,0.001,2084.2,0.059,0.116,0.0065,35071.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-20",24,24,3102,,0.01,0.001,2012.1,0.059,0.109,0.0063,33857.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-21",24,24,3193,,0.01,0.001,2063,0.059,0.119,0.0068,34713.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-22",24,24,3402,,0.011,0.001,2152.5,0.059,0.123,0.0068,36222.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-23",24,24,3227,,0.01,0.001,2071.7,0.059,0.116,0.0066,34861.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-24",24,24,3233,,0.01,0.001,2071.4,0.059,0.118,0.0068,34854.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-25",24,24,2736,,0.009,0.001,1845.7,0.059,0.103,0.0065,31055.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-26",24,24,2891,,0.01,0.001,1911.1,0.059,0.108,0.0067,32156,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-27",24,24,2919,,0.01,0.001,1926.7,0.059,0.108,0.0066,32417.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-28",24,24,3088,,0.01,0.001,2004.9,0.059,0.117,0.007,33736,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-29",24,24,3150,,0.01,0.001,2035.3,0.059,0.106,0.006,34248.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-30",24,24,3220,,0.01,0.001,2065.8,0.059,0.11,0.0063,34759.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-08-31",24,24,3259,,0.011,0.001,2086.4,0.059,0.115,0.0065,35107.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-01",24,24,3221,,0.01,0.001,2079.6,0.059,0.118,0.0067,34992.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-02",24,24,3242,,0.011,0.001,2093.9,0.059,0.112,0.0062,35229.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-03",24,24,3265,,0.011,0.001,2099.9,0.059,0.119,0.0067,35336.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-04",24,24,2967,,0.01,0.001,1963.9,0.059,0.11,0.0066,33044.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-05",17,16.2,2115.04,,0.007,0.001,1376.686,0.059,0.104,0.0099,23163.08,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-06",19,17.93,2446.86,,0.008,0.001,1571.444,0.059,0.108,0.0101,26444.546,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-07",24,24,3079,,0.01,0.001,2013.3,0.059,0.105,0.0061,33870,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-08",24,24,2984,,0.01,0.001,1966.4,0.059,0.093,0.0054,33091,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-09",24,24,3108,,0.01,0.001,2022.4,0.059,0.116,0.0068,34034,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-10",24,24,3226,,0.011,0.001,2080.7,0.059,0.119,0.0068,35015.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-11",24,24,3517,,0.011,0.001,2218.3,0.059,0.13,0.007,37326.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-12",24,24,3292,,0.011,0.001,2111.4,0.059,0.121,0.0068,35525.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-13",24,24,3438,,0.011,0.001,2181.4,0.059,0.125,0.0068,36708.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-14",24,24,3190,,0.01,0.001,2070.1,0.059,0.121,0.007,34836.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-15",24,24,3336,,0.011,0.001,2140.9,0.059,0.124,0.0069,36023.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-16",24,24,3521,,0.011,0.001,2219.8,0.059,0.127,0.0068,37348.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-17",24,24,3579,,0.011,0.001,2245.3,0.059,0.131,0.0069,37782.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-18",21,20.17,3028.67,,0.01,0.001,1899.099,0.059,0.104,0.0065,31957.28,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-20",17,16.65,2258.55,,0.007,0.001,1449.12,0.059,0.112,0.014,24382.45,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-21",24,24,3581,,0.011,0.001,2245.4,0.059,0.132,0.007,37787.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-22",24,24,3315,,0.011,0.001,2122.6,0.059,0.122,0.0068,35717.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-23",24,24,3271,,0.011,0.001,2100.9,0.059,0.119,0.0067,35354.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-24",24,24,3354,,0.011,0.001,2134.9,0.059,0.125,0.007,35923.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-25",24,24,3178,,0.01,0.001,2056.3,0.059,0.12,0.0069,34600.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-26",24,24,3295,,0.011,0.001,2111.9,0.059,0.124,0.007,35539.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-27",24,24,3280,,0.011,0.001,2105.8,0.059,0.123,0.0069,35433.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-28",24,24,3209,,0.01,0.001,2070.2,0.059,0.119,0.0068,34835.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-29",24,24,3153,,0.01,0.001,2046.4,0.059,0.117,0.0068,34436.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-09-30",24,24,3255,,0.011,0.001,2095.9,0.059,0.118,0.0067,35266.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-01",24,24,3438,,0.011,0.001,2171.5,0.059,0.132,0.0072,36533.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-02",24,24,3296,,0.011,0.001,2101.9,0.059,0.123,0.007,35369.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-03",24,24,2689,,0.009,0.001,1820,0.059,0.109,0.0071,30623.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-04",24,24,2548,,0.009,0.001,1754.8,0.059,0.103,0.007,29528.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-05",24,23.23,2441.79,,0.009,0.001,1688.693,0.059,0.099,0.007,28413.95,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-06",14,13.82,1434.82,,0.005,0.001,999.67,0.059,0.097,0.0149,16820.148,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-07",1,0.07,1.47,,0,0.001,2.73,0.059,0.005,0.219,45.983,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-17",11,10.77,1065.04,,0.004,0.001,752.053,0.059,0.084,0.0179,12655.41,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-18",24,24,2314,,0.008,0.001,1650.9,0.059,0.094,0.0068,27774.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-19",12,11.73,1136.78,,0.004,0.001,811.612,0.059,0.046,0.0068,13656.417,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-24",12,11.68,1451.68,,0.005,0.001,955.744,0.059,0.081,0.0153,16081.88,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-25",20,19.25,2698.13,,0.009,0.001,1720.9,0.059,0.117,0.0105,28959.072,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-26",9,8.25,1234.5,,0.004,0.001,773.625,0.059,0.045,0.0067,13017.475,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-27",22,21.5,2684,,0.009,0.001,1770.65,0.059,0.169,0.0178,29795.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-28",23,21.22,2884.6,,0.009,0.001,1853.485,0.059,0.133,0.0148,31188.189,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-29",21,19.99,2791.27,,0.009,0.001,1774.783,0.059,0.138,0.0185,29866.981,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-30",24,24,3317,,0.011,0.001,2116.8,0.059,0.123,0.0069,35620.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-10-31",12,11.27,1583.25,,0.005,0.001,1005.008,0.059,0.058,0.0068,16913.412,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-01",20,19.98,2599.76,,0.009,0.001,1691.724,0.059,0.159,0.0135,28467.178,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-02",20,18.58,2629.58,,0.008,0.001,1672.764,0.059,0.125,0.0175,28147.584,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-03",24,24,3543,,0.011,0.001,2236.2,0.059,0.13,0.0069,37626.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-04",7,6.27,976.03,,0.003,0.001,609.663,0.059,0.036,0.0069,10259.458,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-06",7,6.22,793.64,,0.003,0.001,518.606,0.059,0.062,0.0387,8726.168,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-07",20,18.83,2757,,0.009,0.001,1741.838,0.059,0.128,0.0094,29309.789,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-08",18,17.78,2478.84,,0.008,0.001,1583.002,0.059,0.131,0.0123,26640.506,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-09",20,19.15,2908.9,,0.009,0.001,1823.36,0.059,0.155,0.0135,30680.305,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-10",24,24,3510,,0.011,0.001,2219.1,0.059,0.126,0.0068,37343.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-11",24,24,3550,,0.011,0.001,2236.6,0.059,0.127,0.0068,37635.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-12",24,24,3316,,0.011,0.001,2128.5,0.059,0.124,0.0069,35820.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-13",24,24,3346,,0.011,0.001,2140.2,0.059,0.124,0.0069,36015.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-14",24,24,3324,,0.011,0.001,2129.8,0.059,0.123,0.0068,35837.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-15",24,24,3387,,0.011,0.001,2162.5,0.059,0.127,0.007,36389.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-16",24,24,2971,,0.01,0.001,1963.1,0.059,0.114,0.0069,33035.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-17",20,18.37,2463.37,,0.008,0.001,1589.589,0.059,0.111,0.0148,26749.457,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-18",24,24,3252,,0.011,0.001,2092.8,0.059,0.122,0.0069,35213.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-19",24,24,3346,,0.011,0.001,2142.6,0.059,0.124,0.0069,36051.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-20",24,24,3733,,0.012,0.001,2324.7,0.059,0.136,0.007,39117.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-21",24,24,3768,,0.012,0.001,2343.9,0.059,0.137,0.007,39444.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-22",24,24,3562,,0.011,0.001,2244.7,0.059,0.132,0.007,37773.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-23",24,24,3275,,0.011,0.001,2103.2,0.059,0.122,0.0069,35386.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-24",24,24,3038,,0.01,0.001,1999.6,0.059,0.116,0.0069,33645.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-25",24,24,3067,,0.01,0.001,2012.1,0.059,0.118,0.007,33858.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-26",24,24,3260,,0.011,0.001,2106.1,0.059,0.123,0.0069,35437.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-27",24,24,3062,,0.01,0.001,2009.3,0.059,0.118,0.007,33811.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-28",24,24,3083,,0.01,0.001,2017.2,0.059,0.117,0.0069,33940.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-29",8,7.48,997.24,,0.003,0.001,650.012,0.059,0.036,0.0065,10938.22,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-01",1,0.4,10.8,,0,0.001,14.76,0.059,0.029,0.234,248.52,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-02",21,20.2,2691,,0.009,0.001,1763.02,0.059,0.16,0.041,29665.92,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-03",22,20.81,2956.6,,0.01,0.001,1897.791,0.059,0.143,0.0095,31931.055,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-04",22,21.21,3033.71,,0.01,0.001,1936.44,0.059,0.142,0.0166,32584.387,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-05",21,19.42,2685.53,,0.009,0.001,1730.885,0.059,0.152,0.0193,29125.107,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-06",22,20.68,2998.79,,0.01,0.001,1902.93,0.059,0.168,0.0167,32020.767,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-07",24,24,3588,,0.011,0.001,2259.4,0.059,0.134,0.007,38018.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-08",21,19.95,2889.6,,0.009,0.001,1833.645,0.059,0.144,0.0104,30852.39,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-09",24,24,3155,,0.01,0.001,2052.6,0.059,0.122,0.0071,34539.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-10",22,20.88,3014.89,,0.01,0.001,1916.324,0.059,0.147,0.015,32246.504,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-11",20,19.2,2870.44,,0.009,0.001,1814.772,0.059,0.175,0.0408,30535.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-12",21,19.25,2703.56,,0.009,0.001,1734.933,0.059,0.146,0.0112,29194.368,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-13",24,24,3318,,0.011,0.001,2142.3,0.059,0.127,0.007,36052.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-14",24,24,3198,,0.011,0.001,2080.5,0.059,0.123,0.007,35010.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-15",24,24,3210,,0.011,0.001,2089.7,0.059,0.125,0.0071,35166.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-16",22,21.06,2830.91,,0.009,0.001,1840.031,0.059,0.13,0.0123,30961.217,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-17",9,8.22,1094.28,,0.004,0.001,712.586,0.059,0.043,0.0071,11992.33,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-18",10,9.43,1157.05,,0.004,0.001,774.155,0.059,0.11,0.0292,13023.681,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-19",20,19.47,2466.15,,0.008,0.001,1634.767,0.059,0.222,0.041,27511.25,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-20",24,24,3125,,0.01,0.001,2048.7,0.059,0.118,0.0069,34469.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-21",9,8.25,1074.25,,0.004,0.001,703.65,0.059,0.042,0.0069,11838.425,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-22",8,7.4,952.8,,0.003,0.001,625.42,0.059,0.104,0.044,10522.04,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-23",20,18.92,2570.72,,0.008,0.001,1660.452,0.059,0.142,0.0131,27939.516,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-24",24,24,3383,,0.011,0.001,2164.4,0.059,0.127,0.007,36420.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-25",24,24,3060,,0.01,0.001,2009.5,0.059,0.119,0.007,33813.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-26",24,24,2952,,0.01,0.001,1955.8,0.059,0.114,0.0069,32911.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-27",24,24,3222,,0.011,0.001,2083.4,0.059,0.124,0.0071,35062.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-28",12,11.7,1607.6,,0.005,0.001,1032,0.059,0.062,0.0072,17367.21,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"1",,"2020-12-31",11,10.72,1517.16,,0.005,0.001,971.5,0.059,0.056,0.0065,16347.776,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-01",4,3.45,454.5,,0.002,0.001,299.87,0.059,0.018,0.007,5045.345,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-02",10,9.83,1284.48,,0.004,0.001,855.611,0.059,0.093,0.0184,14398,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-03",20,19.05,2614.37,,0.009,0.001,1719.361,0.059,0.134,0.0111,28933.489,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-04",19,18.36,2684.32,,0.009,0.001,1734.956,0.059,0.133,0.0106,29194.628,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-05",19,18.33,2783.51,,0.009,0.001,1791.275,0.059,0.132,0.0101,30138.743,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-06",19,18.11,2734.59,,0.009,0.001,1763.71,0.059,0.139,0.0107,29678.852,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-07",9,8.25,1110.5,,0.004,0.001,730.85,0.059,0.043,0.0069,12296.825,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-17",4,2.38,0,,0,0.001,58.38,0.0593,0.104,0.208,982.384,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-18",9,8.2,845.46,,0.003,0.001,604.816,0.059,0.424,0.1567,10178.632,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-02",4,3.17,338.04,,0.001,0.001,239.307,0.059,0.075,0.0758,4027.669,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-03",1,0.47,51.7,,0,0.001,36.66,0.059,0.002,0.006,616.593,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-04",2,1.73,118.77,,0.001,0.001,99.959,0.059,0.57,0.678,1681.306,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-05",24,24,2812,,0.01,0.001,1925.6,0.059,0.139,0.0091,32401.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-06",24,24,2897,,0.01,0.001,1965.8,0.059,0.109,0.0065,33081.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-07",24,24,2820,,0.01,0.001,1925,0.059,0.106,0.0066,32396,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-08",20,17.95,2090.7,,0.007,0.001,1427.113,0.059,0.159,0.0236,24012.478,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-09",24,24,3256,,0.011,0.001,2131.2,0.059,0.117,0.0065,35859.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-10",24,24,3074,,0.01,0.001,2045.7,0.059,0.113,0.0066,34420.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-11",24,24,2640,,0.009,0.001,1845.4,0.059,0.104,0.0067,31056.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-12",24,24,3249,,0.011,0.001,2128.2,0.059,0.124,0.0069,35808.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-13",24,24,3159,,0.011,0.001,2083.4,0.059,0.118,0.0068,35058.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-14",24,24,2829,,0.01,0.001,1932.4,0.059,0.107,0.0066,32518,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-15",24,24,2756,,0.01,0.001,1892,0.059,0.108,0.0068,31836.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-16",24,24,3217,,0.011,0.001,2103.7,0.059,0.121,0.0068,35401.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-17",24,24,2739,,0.01,0.001,1885.1,0.059,0.102,0.0064,31721,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-18",24,24,3104,,0.01,0.001,2055.9,0.059,0.117,0.0068,34593.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-19",24,24,2812,,0.01,0.001,1924.9,0.059,0.11,0.0068,32391.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-20",24,24,2893,,0.01,0.001,1965,0.059,0.115,0.007,33064.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-21",10,9.25,1148,,0.004,0.001,773.025,0.059,0.045,0.0068,13010.825,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-22",11,10.52,1303.84,,0.004,0.001,876.944,0.059,0.108,0.0258,14757.588,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-23",15,13.37,1612.8,,0.006,0.001,1090.245,0.0591,0.103,0.0154,18342.242,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-24",20,19.17,2505.26,,0.008,0.001,1666.146,0.059,0.142,0.0126,28034.047,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-25",6,5.77,838.97,,0.003,0.001,540.078,0.059,0.032,0.007,9085.635,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-26",11,10.6,1170.8,,0.004,0.001,815.024,0.059,0.076,0.0135,13715.016,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-28",7,6.03,771,,0.003,0.0009,516.432,0.059,0.078,0.0217,8689.22,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-29",10,9.72,1490.44,,0.005,0.001,947.816,0.059,0.055,0.0068,15953.332,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-05",4,3.13,295.82,,0.001,0.001,218.67,0.059,0.07,0.07,3680.062,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-06",21,20.2,2718.44,,0.009,0.001,1789.168,0.059,0.15,0.019,30108.584,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-07",9,8.28,1059.56,,0.004,0.001,701.488,0.059,0.038,0.0062,11806.368,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-13",8,7.02,947,,0.003,0.001,626.396,0.059,0.097,0.0218,10540.718,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-14",19,18.15,2644.43,,0.009,0.001,1713.692,0.059,0.143,0.0144,28838.852,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-15",8,7.28,1027.72,,0.003,0.001,672.048,0.059,0.039,0.0069,11308.064,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-16",9,8.27,989.75,,0.003,0.001,673.942,0.059,0.086,0.0399,11338.721,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-17",8,7.3,948.6,,0.003,0.001,627.49,0.059,0.035,0.0065,10558.49,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-19",5,4.7,444,,0.002,0.001,328.3,0.059,0.08,0.0414,5523.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-20",14,13.07,1486.37,,0.005,0.001,1029.741,0.059,0.091,0.0131,17325.576,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-21",7,6.2,828.2,,0.003,0.001,546.58,0.059,0.029,0.0063,9197.14,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-22",6,5.95,718.1,,0.002,0.001,490.965,0.059,0.076,0.0252,8261.735,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-23",18,17.02,2349.1,,0.008,0.001,1550.668,0.059,0.115,0.0106,26095.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-24",20,18.9,2405.97,,0.008,0.001,1614.4,0.059,0.122,0.0151,27164.819,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-25",20,19.07,2703.57,,0.009,0.001,1760.732,0.059,0.133,0.0114,29628.014,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-26",17,16.46,2302.92,,0.008,0.001,1518.314,0.059,0.121,0.0119,25547.82,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-27",2,1.25,147.25,,0.001,0.001,101.4,0.059,0.006,0.0065,1706.225,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-28",11,10.47,1209.57,,0.004,0.001,834.259,0.059,0.093,0.0278,14039.095,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-29",19,17.75,2169.55,,0.007,0.001,1472.06,0.059,0.113,0.0144,24769.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-04-30",4,3.25,363.75,,0.001,0.001,253.825,0.059,0.014,0.0065,4271.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-07",12,11.67,1180.48,,0.004,0.001,849.319,0.059,0.113,0.0238,14291.164,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-08",14,13.05,1761.8,,0.006,0.001,1163.832,0.059,0.096,0.0132,19585.972,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-09",2,1.22,146.96,,0.001,0.001,99.438,0.059,0.008,0.0175,1672.578,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-26",15,14.12,1563.08,,0.006,0.001,1096.036,0.0591,0.094,0.0535,18441.124,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-27",24,24,2350,,0.009,0.001,1711.6,0.059,0.097,0.0067,28807.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-28",24,24,2937,,0.01,0.001,1989.5,0.059,0.113,0.0068,33474.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-29",24,24,3225,,0.011,0.001,2136,0.059,0.122,0.0068,35941.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-30",3,2.25,297.75,,0.001,0.001,197.7,0.059,0.012,0.0067,3325.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-01",23,22.2,3338.4,,0.011,0.001,2145.52,0.059,0.164,0.0185,36099.96,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-02",24,24,3572,,0.012,0.001,2288.5,0.059,0.131,0.0068,38509.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-03",24,24,3786,,0.012,0.001,2380.7,0.059,0.139,0.0069,40061.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-04",24,24,3693,,0.012,0.001,2364.9,0.059,0.136,0.0068,39789.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-05",24,24,2982,,0.01,0.001,2013.1,0.059,0.111,0.0064,33872.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-06",7,6.27,907.71,,0.003,0.001,584.354,0.059,0.033,0.0066,9832.226,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-08",12,11.22,1428.84,,0.005,0.001,950.36,0.059,0.106,0.0343,15991.878,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-09",19,17.72,2402.16,,0.008,0.001,1565.664,0.059,0.127,0.0198,26346.924,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-10",24,24,3305,,0.011,0.001,2148.6,0.059,0.125,0.0069,36153.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-11",24,24,3385,,0.011,0.001,2198.2,0.059,0.126,0.0068,36992.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-12",2,2,261,,0.001,0.001,173,0.059,0.01,0.0065,2910.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-17",6,5.02,445,,0.002,0.001,332.876,0.059,0.076,0.0265,5601.594,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-18",19,17.93,2308.07,,0.008,0.001,1530.068,0.059,0.11,0.0108,25742.169,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-19",24,24,3152,,0.01,0.001,2079.2,0.059,0.113,0.0065,34986.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-20",2,1.2,130.2,,0,0.001,91.76,0.059,0.005,0.0055,1544.66,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-22",15,14.97,2104.35,,0.007,0.001,1367.779,0.059,0.118,0.0131,23014.71,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-23",24,24,3182,,0.011,0.001,2090.1,0.059,0.121,0.0069,35169.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-24",24,24,3288,,0.011,0.001,2144.8,0.059,0.122,0.0067,36090.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-25",24,24,3236,,0.011,0.001,2112.8,0.059,0.122,0.0069,35550.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-26",24,24,3191,,0.011,0.001,2100,0.059,0.12,0.0068,35335.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-27",24,24,3557,,0.012,0.001,2280.7,0.059,0.129,0.0067,38374.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-28",7,6.82,867.22,,0.003,0.001,575.524,0.059,0.033,0.0067,9683.862,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-05",10,9.7,1090.4,,0.004,0.001,747.57,0.059,0.117,0.0302,12581.83,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-06",23,22.33,2229.08,,0.008,0.001,1595.132,0.059,0.075,0.0053,26838.947,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-07",16,15.18,1857.42,,0.006,0.001,1250.608,0.059,0.094,0.0186,21043.046,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-08",24,24,2966,,0.01,0.001,1988.6,0.059,0.11,0.0066,33457.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-09",24,24,3042,,0.01,0.001,2030.8,0.059,0.115,0.0067,34171.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-10",24,24,3140,,0.011,0.001,2084,0.059,0.111,0.0061,35065.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-11",24,24,3724,,0.012,0.001,2374.1,0.059,0.135,0.0068,39945.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-12",24,24,3387,,0.011,0.001,2198.9,0.059,0.117,0.006,37003.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-13",24,24,3437,,0.011,0.001,2217.9,0.059,0.124,0.0066,37319.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-14",24,24,2934,,0.01,0.001,1968.2,0.059,0.111,0.0067,33118.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-15",24,24,2749,,0.01,0.001,1886,0.059,0.108,0.0068,31738.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-16",24,24,2837,,0.01,0.001,1927.8,0.059,0.111,0.0068,32437.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-17",24,24,2816,,0.01,0.001,1923,0.059,0.103,0.0063,32353.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-18",24,24,3085,,0.01,0.001,2055.5,0.059,0.118,0.0068,34591.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-19",19,18.04,2246.56,,0.008,0.001,1516.568,0.059,0.132,0.0138,25516.852,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-20",24,24,4255,,0.013,0.001,2661,0.059,0.155,0.0069,44775.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-21",24,24,3271,,0.011,0.001,2143.5,0.059,0.121,0.0067,36068.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-22",24,24,3185,,0.011,0.001,2099.7,0.059,0.116,0.0065,35328.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-23",24,24,3241,,0.011,0.001,2123.1,0.059,0.121,0.0068,35726.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-24",5,4.5,615,,0.002,0.001,399.7,0.059,0.022,0.0064,6725.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-25",15,14.78,2145.12,,0.007,0.001,1384.112,0.059,0.126,0.0151,23290.972,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-26",24,24,3591,,0.012,0.001,2303.4,0.059,0.133,0.0069,38759.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-27",24,24,3318,,0.011,0.001,2158.2,0.059,0.12,0.0066,36314.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-28",24,24,3227,,0.011,0.001,2116.2,0.059,0.121,0.0068,35614,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-29",24,24,2991,,0.01,0.001,2014.3,0.059,0.111,0.0065,33893,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-30",24,24,3029,,0.01,0.001,2034.4,0.059,0.113,0.0066,34232.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-07-31",24,24,3100,,0.01,0.001,2071.1,0.059,0.118,0.0068,34846.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-01",24,24,3375,,0.011,0.001,2205.5,0.059,0.123,0.0066,37113.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-02",24,24,3234,,0.011,0.001,2126.3,0.059,0.096,0.0054,35781,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-03",4,3.3,399.3,,0.001,0.001,270.22,0.059,0.016,0.0068,4546.47,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-09",3,2.15,209.25,,0.001,0.001,153.51,0.059,0.066,0.1107,2582.925,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-10",24,24,3211,,0.011,0.001,2119.2,0.059,0.12,0.0068,35662.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-11",24,24,3252,,0.011,0.001,2142,0.059,0.117,0.0064,36039.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-12",24,24,3643,,0.012,0.001,2321.4,0.059,0.131,0.0067,39060.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-13",24,24,3572,,0.012,0.001,2298,0.059,0.129,0.0067,38664.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-14",21,20.16,2883.2,,0.009,0.001,1864.027,0.059,0.112,0.0112,31363.675,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-15",24,24,3365,,0.011,0.001,2203.7,0.059,0.124,0.0067,37081.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-16",24,24,3145,,0.011,0.001,2082.2,0.059,0.118,0.0067,35040.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-17",24,24,3610,,0.012,0.001,2314,0.059,0.13,0.0067,38936.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-18",24,24,3242,,0.011,0.001,2119.3,0.059,0.116,0.0065,35663,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-19",24,24,3258,,0.011,0.001,2119.6,0.059,0.117,0.0065,35665.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-20",24,24,3088,,0.01,0.001,2042.2,0.059,0.115,0.0067,34365.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-21",24,24,3188,,0.011,0.001,2103.3,0.059,0.123,0.007,35389.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-22",24,24,3393,,0.011,0.001,2193.2,0.059,0.122,0.0066,36905.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-23",24,23.35,3074.35,,0.01,0.001,2021.215,0.059,0.126,0.01,34011.795,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-24",24,24,3225,,0.011,0.001,2106.4,0.059,0.121,0.0068,35444.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-25",24,24,2710,,0.009,0.001,1866.7,0.059,0.11,0.007,31408.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-26",24,24,2881,,0.01,0.001,1938.2,0.059,0.111,0.0068,32615.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-27",24,24,2903,,0.01,0.001,1955,0.059,0.114,0.0069,32897.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-28",24,24,3049,,0.01,0.001,2024.7,0.059,0.118,0.0069,34068.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-29",24,24,3110,,0.01,0.001,2053.4,0.059,0.107,0.0061,34548.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-30",24,24,3213,,0.011,0.001,2099.9,0.059,0.115,0.0065,35335.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-08-31",24,24,3246,,0.011,0.001,2119.9,0.059,0.117,0.0066,35666.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-01",24,24,3203,,0.011,0.001,2107.8,0.059,0.114,0.0064,35466.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-02",24,24,3220,,0.011,0.001,2122.5,0.059,0.115,0.0064,35713.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-03",24,24,3255,,0.011,0.001,2133.4,0.059,0.113,0.0063,35900.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-04",24,24,2947,,0.01,0.001,1990.3,0.059,0.111,0.0067,33487.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-05",16,15.06,2002.44,,0.007,0.001,1319.001,0.059,0.099,0.0111,22197.493,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-06",18,16.93,2334.22,,0.008,0.001,1523.736,0.059,0.11,0.0114,25642.014,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-07",24,24,3076,,0.01,0.001,2045.5,0.059,0.114,0.0066,34419.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-08",24,24,2939,,0.01,0.001,1979.9,0.059,0.103,0.006,33316.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-09",24,24,3094,,0.01,0.001,2048.3,0.059,0.12,0.0069,34467,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-10",24,24,3194,,0.011,0.001,2100,0.059,0.118,0.0066,35334.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-11",24,24,3513,,0.011,0.001,2254.7,0.059,0.129,0.0068,37942.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-12",24,24,3262,,0.011,0.001,2133.1,0.059,0.121,0.0067,35893.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-13",24,24,3430,,0.011,0.001,2216.7,0.059,0.127,0.0068,37300.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-14",24,24,3154,,0.011,0.001,2090.7,0.059,0.117,0.0066,35180.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-15",24,24,3314,,0.011,0.001,2172.7,0.059,0.12,0.0065,36556.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-16",24,24,3514,,0.011,0.001,2257.4,0.059,0.126,0.0066,37987.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-17",24,24,3566,,0.012,0.001,2287.7,0.059,0.127,0.0066,38493.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-18",21,20.17,3023.67,,0.01,0.001,1934.122,0.059,0.11,0.0068,32545.301,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-19",22,21.72,3328.04,,0.011,0.001,2142.952,0.059,0.147,0.0102,36060.272,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-20",24,24,3462,,0.011,0.001,2235.2,0.059,0.129,0.0068,37610.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-21",24,24,3573,,0.012,0.001,2285.5,0.059,0.127,0.0066,38457,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-22",24,24,3296,,0.011,0.001,2154,0.059,0.115,0.0063,36241,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-23",24,24,3234,,0.011,0.001,2121.9,0.059,0.111,0.0061,35704.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-24",24,24,3343,,0.011,0.001,2169.4,0.059,0.122,0.0067,36506.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-25",24,24,3167,,0.011,0.001,2088,0.059,0.117,0.0067,35130.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-26",24,24,3277,,0.011,0.001,2141.3,0.059,0.12,0.0066,36034.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-27",24,24,3263,,0.011,0.001,2136.4,0.059,0.121,0.0067,35949.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-28",24,24,3200,,0.011,0.001,2102.9,0.059,0.116,0.0066,35385.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-29",24,24,3133,,0.01,0.001,2073.7,0.059,0.111,0.0063,34896.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-09-30",24,24,3227,,0.011,0.001,2121.8,0.059,0.116,0.0064,35704.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-01",24,24,3415,,0.011,0.001,2199.6,0.059,0.126,0.0068,37015,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-02",24,24,3284,,0.011,0.001,2132.6,0.059,0.116,0.0065,35884.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-03",24,24,2650,,0.009,0.001,1829.6,0.059,0.101,0.0065,30787.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-04",24,24,2524,,0.009,0.001,1766.9,0.059,0.098,0.0066,29734.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-05",24,24,2534,,0.009,0.001,1773.4,0.059,0.101,0.0068,29838.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-06",24,24,3166,,0.011,0.001,2095.4,0.059,0.122,0.0069,35260.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-07",24,24,3449,,0.011,0.001,2231.3,0.059,0.126,0.0067,37547.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-08",24,24,3643,,0.012,0.001,2315.8,0.059,0.129,0.0066,38967.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-09",24,24,4002,,0.013,0.001,2516.8,0.059,0.146,0.0069,42352.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-10",24,24,3836,,0.012,0.001,2441.4,0.059,0.142,0.0069,41085.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-11",24,24,3781,,0.012,0.001,2416.8,0.059,0.139,0.0068,40665.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-12",24,24,3924,,0.013,0.001,2499.6,0.059,0.146,0.007,42062,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-13",24,24,3671,,0.012,0.001,2361.5,0.059,0.138,0.007,39735.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-14",23,21.98,2798.42,,0.009,0.001,1862.928,0.059,0.139,0.0177,31350.106,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-15",24,24,3483,,0.011,0.001,2252.6,0.059,0.131,0.0069,37904.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-16",24,24,3509,,0.011,0.001,2254.6,0.059,0.128,0.0068,37940.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-17",24,24,3080,,0.01,0.001,2041.8,0.059,0.118,0.0069,34360.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-18",24,24,2281,,0.008,0.001,1656.5,0.059,0.095,0.0068,27874,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-19",24,24,3204,,0.011,0.001,2124.7,0.059,0.125,0.007,35752.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-20",24,24,3895,,0.012,0.001,2448.7,0.059,0.144,0.007,41207.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-21",24,24,3478,,0.011,0.001,2232.9,0.059,0.128,0.0068,37575.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-22",24,24,3414,,0.011,0.001,2210.7,0.059,0.127,0.0068,37199.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-23",24,24,3609,,0.012,0.001,2313.9,0.059,0.131,0.0067,38935.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-24",21,19.38,2715.74,,0.009,0.001,1774.142,0.059,0.127,0.0166,29851.27,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-25",21,19.93,2751.11,,0.009,0.001,1790.809,0.059,0.132,0.0166,30134.917,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-26",21,20.1,2971.45,,0.01,0.001,1921.115,0.059,0.158,0.0126,32323.75,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-27",24,24,3140,,0.01,0.001,2078.5,0.059,0.122,0.007,34974.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-28",24,24,3143,,0.01,0.001,2073.8,0.059,0.121,0.007,34894.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-29",24,24,3203,,0.011,0.001,2097.5,0.059,0.123,0.007,35296.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-30",20,19.47,2781.04,,0.009,0.001,1788.862,0.059,0.145,0.0125,30100.511,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-10-31",24,24,3617,,0.012,0.001,2316.2,0.059,0.135,0.0069,38975.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-01",24,24,3274,,0.011,0.001,2143.9,0.059,0.123,0.0068,36076.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-02",19,16.81,2412.72,,0.008,0.001,1557.482,0.059,0.174,0.0365,26206.028,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-03",11,10.73,1526.84,,0.005,0.001,985.299,0.059,0.058,0.007,16582.628,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-04",3,2.7,253.5,,0.001,0.001,187.38,0.059,0.04,0.0393,3152.24,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-05",24,24,3870,,0.012,0.001,2459.7,0.059,0.144,0.007,41392.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-06",24,24,3771,,0.012,0.001,2391.8,0.059,0.139,0.0069,40245.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-07",19,18.27,2675.77,,0.009,0.001,1721.081,0.059,0.126,0.0135,28960.556,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-08",18,17.08,2393.36,,0.008,0.001,1555.444,0.0591,0.124,0.0183,26174.652,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-09",20,18.44,2833.9,,0.009,0.001,1804.39,0.059,0.139,0.0177,30363.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-10",12,11.1,1691.64,,0.005,0.001,1076.732,0.059,0.075,0.0223,18120.066,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-11",24,24,3485,,0.011,0.001,2246.4,0.059,0.18,0.0108,37802.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-12",24,24,3278,,0.011,0.001,2146.3,0.059,0.125,0.0069,36116.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-13",12,11,1505.51,,0.005,0.001,988.811,0.059,0.096,0.0198,16639.28,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-14",21,20.15,2841.3,,0.009,0.001,1843.63,0.059,0.146,0.0177,31024.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-15",20,18.4,2744.91,,0.009,0.001,1760.867,0.059,0.136,0.0181,29631.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-16",24,24,2912,,0.01,0.001,1964.7,0.059,0.112,0.0068,33058.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-17",24,24,3007,,0.01,0.001,2010.4,0.059,0.118,0.007,33830.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-18",24,24,3236,,0.011,0.001,2119.2,0.059,0.124,0.007,35662,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-19",21,19.81,2884.05,,0.009,0.001,1860.666,0.059,0.14,0.0173,31308.405,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-20",24,24,3729,,0.012,0.001,2364.5,0.059,0.138,0.0069,39789.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-21",24,24,3760,,0.012,0.001,2385.6,0.059,0.14,0.007,40140,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-22",24,24,3551,,0.011,0.001,2277.8,0.059,0.137,0.0072,38328.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-23",24,24,3256,,0.011,0.001,2128.1,0.059,0.125,0.007,35806.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-24",24,24,3021,,0.01,0.001,2025.5,0.059,0.119,0.007,34081.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-25",24,24,3004,,0.01,0.001,2012,0.059,0.119,0.007,33857.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-26",24,24,3209,,0.011,0.001,2118.8,0.059,0.123,0.0069,35652.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-27",24,24,3022,,0.01,0.001,2021.5,0.059,0.117,0.0069,34017.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-28",24,24,3035,,0.01,0.001,2026.5,0.059,0.119,0.007,34103,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-29",16,14.7,1941.22,,0.007,0.001,1288.546,0.059,0.111,0.0226,21680.95,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-11-30",21,20.38,2822.83,,0.009,0.001,1841.838,0.059,0.156,0.0161,30992.874,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-01",24,24,3390,,0.011,0.001,2233.4,0.059,0.132,0.007,37578.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-02",24,24,3371,,0.011,0.001,2218.1,0.059,0.131,0.007,37321.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-03",24,24,3257,,0.011,0.001,2150.9,0.059,0.126,0.007,36193.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-04",24,24,3341,,0.011,0.001,2181.1,0.059,0.133,0.0073,36700.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-05",20,18.55,2605.25,,0.009,0.001,1694.77,0.059,0.126,0.0125,28516.35,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-06",21,19.93,2934.3,,0.01,0.001,1888.22,0.059,0.141,0.0099,31775.326,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-07",24,24,3569,,0.012,0.001,2292.8,0.059,0.137,0.0071,38576,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-08",24,24,3416,,0.011,0.001,2213.2,0.059,0.132,0.0071,37237.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-09",23,21.15,2789.32,,0.009,0.001,1843.274,0.059,0.143,0.0098,31014.494,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-10",21,20.03,2916,,0.01,0.001,1885.875,0.059,0.124,0.01,31730.682,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-11",24,24,3363,,0.011,0.001,2198.8,0.059,0.124,0.0066,37002.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-12",20,18.52,2623.58,,0.009,0.001,1710.76,0.059,0.135,0.0181,28787.296,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-13",22,20.82,2916.56,,0.01,0.001,1906.124,0.059,0.146,0.0159,32073.393,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-14",24,24,3185,,0.011,0.001,2106.1,0.059,0.129,0.0073,35439.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-15",24,24,3199,,0.011,0.001,2117.1,0.059,0.129,0.0073,35625.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-16",24,24,3175,,0.011,0.001,2105.4,0.059,0.127,0.0072,35427.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-17",19,17.51,2372.77,,0.008,0.001,1561.814,0.059,0.137,0.0188,26280.029,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-18",21,19.73,2561.89,,0.009,0.001,1708.36,0.059,0.128,0.0125,28745.475,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-19",24,24,3160,,0.011,0.001,2104,0.059,0.126,0.0071,35402.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-20",24,24,3067,,0.01,0.001,2052.8,0.059,0.115,0.0067,34546.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-21",9,8.25,1072,,0.004,0.001,712.275,0.059,0.042,0.007,11985.075,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-22",12,11.7,1467.8,,0.005,0.001,985.16,0.059,0.108,0.0189,16578.49,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-23",21,19.7,2630.68,,0.009,0.001,1735.606,0.059,0.176,0.02,29201.546,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-24",24,24,3371,,0.011,0.001,2192.1,0.059,0.139,0.0075,36888.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-25",24,24,3007,,0.01,0.001,2014.1,0.059,0.12,0.0071,33892.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-26",24,24,2865,,0.01,0.001,1944,0.059,0.115,0.007,32706.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-27",24,24,3191,,0.011,0.001,2100.6,0.059,0.125,0.0071,35349.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-28",24,24,3156,,0.011,0.001,2087.2,0.059,0.123,0.007,35124.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-29",24,24,3445,,0.011,0.001,2232.8,0.059,0.132,0.007,37572.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-30",21,19.49,2799.29,,0.009,0.001,1808.817,0.059,0.151,0.0186,30439.879,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Blythe Energy",55295,"2",,"2020-12-31",21,19.9,2895.6,,0.009,0.001,1867.435,0.059,0.17,0.0135,31423.922,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-01",8,7.45,1799.8,,0.004,0.001,732.62,0.059,0.055,0.0094,12328.425,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-02",20,18.38,4093.56,,0.009,0.001,1755.309,0.059,0.268,0.0276,29536.436,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-03",24,24,6276,,0.013,0.001,2516.8,0.059,0.187,0.0088,42346.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-04",20,18.23,4305.66,,0.009,0.001,1803.65,0.059,0.187,0.0198,30347.846,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-05",21,19.28,4911.32,,0.01,0.001,2016.672,0.059,0.201,0.0214,33934.064,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-06",24,24,6210,,0.013,0.001,2477.5,0.059,0.185,0.0089,41688.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-07",24,24,6540,,0.013,0.001,2597.8,0.059,0.195,0.0089,43708.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-08",24,24,6197,,0.013,0.001,2550.9,0.059,0.192,0.009,42923.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-09",19,17.84,4776.2,,0.01,0.001,1920.682,0.059,0.177,0.0149,32321.963,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-10",24,24,6426,,0.013,0.001,2561,0.059,0.189,0.0088,43092.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-11",20,18.45,4261.37,,0.009,0.001,1775.761,0.0591,0.198,0.0232,29880.244,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-12",13,12.12,2808.44,,0.006,0.001,1158.164,0.059,0.134,0.02,19487.684,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-13",24,24,6322,,0.013,0.001,2534.9,0.059,0.189,0.0089,42655.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-14",24,24,6200,,0.013,0.001,2492.8,0.059,0.186,0.0089,41947.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-15",24,24,6482,,0.013,0.001,2576.5,0.059,0.193,0.0089,43356.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-16",24,24,6476,,0.013,0.001,2581.1,0.059,0.193,0.0089,43429.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-17",24,24,6352,,0.013,0.001,2534.3,0.059,0.186,0.0087,42644.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-18",24,24,6100,,0.013,0.001,2476.2,0.059,0.18,0.0087,41665.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-19",18,16.72,4138.59,,0.009,0.001,1798.346,0.059,0.197,0.0183,30259.513,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-20",24,24,6683,,0.014,0.001,2801.6,0.059,0.199,0.0085,47145.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-21",24,24,6296,,0.013,0.001,2600.8,0.059,0.186,0.0085,43760.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-22",24,24,5555,,0.011,0.001,2248.1,0.059,0.169,0.0089,37828.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-23",24,24,6116,,0.013,0.001,2488.1,0.059,0.176,0.0084,41864.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-24",4,3.15,810.3,,0.002,0.001,324.795,0.059,0.026,0.0133,5465.06,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-25",9,8.47,2152.39,,0.004,0.001,887.218,0.059,0.113,0.0258,14926.881,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-26",12,11.15,2634.95,,0.005,0.001,1079.16,0.059,0.12,0.0191,18161.505,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-27",24,24,5393,,0.011,0.001,2205.4,0.059,0.167,0.009,37112,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-28",23,21.35,5277.18,,0.011,0.001,2160.051,0.059,0.199,0.0137,36346.942,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-29",15,13.68,3303.48,,0.007,0.001,1379.822,0.0591,0.157,0.0229,23214.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-30",24,24,6312,,0.013,0.001,2530.9,0.059,0.181,0.0085,42587.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-01-31",20,18.33,4836.04,,0.01,0.001,1947.436,0.059,0.17,0.0159,32770.209,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-01",17,15.87,3525.02,,0.008,0.001,1486.012,0.059,0.181,0.025,25003.799,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-02",3,2.17,568.6,,0.001,0.001,226.187,0.059,0.019,0.022,3805.281,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-03",21,19.64,4608.54,,0.01,0.001,1947.546,0.059,0.267,0.0242,32771.988,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-04",24,24,6496,,0.013,0.001,2611.9,0.059,0.187,0.0085,43952.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-05",24,24,6455,,0.013,0.001,2601.4,0.059,0.186,0.0085,43772.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-06",22,21.36,5448.92,,0.011,0.001,2222.308,0.059,0.216,0.0152,37396.564,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-07",19,17.28,4221.77,,0.009,0.001,1718.875,0.0591,0.161,0.0176,28925.878,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-08",3,2.17,549.75,,0.001,0.001,218.977,0.059,0.021,0.0313,3684.034,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-09",7,6.95,1730.5,,0.004,0.001,713.985,0.059,0.105,0.027,12014.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-10",22,21.02,5310.64,,0.011,0.001,2161.688,0.059,0.202,0.014,36373.064,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-11",22,21.07,5386.82,,0.011,0.001,2193.343,0.059,0.188,0.0125,36905.387,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-12",24,24,6195,,0.013,0.001,2484.7,0.059,0.179,0.0086,41806.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-13",22,20.92,5353.35,,0.011,0.001,2175.215,0.059,0.19,0.013,36607.29,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-14",21,20.59,5150.55,,0.011,0.001,2109.391,0.059,0.247,0.0189,35488.522,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-15",21,20.07,5024.07,,0.01,0.001,2074.687,0.059,0.233,0.019,34908.568,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-16",10,8.8,2216.93,,0.005,0.001,896.065,0.059,0.099,0.0216,15080.08,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-17",19,17.74,4149.78,,0.009,0.001,1686.164,0.059,0.164,0.0213,28374.47,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-18",19,17.85,4678.25,,0.009,0.001,1878.48,0.059,0.176,0.0165,31607.51,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-19",19,18.64,4913.25,,0.01,0.001,1974.917,0.059,0.187,0.0149,33232.684,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-20",22,21,5480.2,,0.011,0.001,2225.14,0.059,0.222,0.0162,37443.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-21",24,24,6197,,0.012,0.001,2470.3,0.059,0.182,0.0088,41567.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-22",3,2.47,633.25,,0.001,0.001,252.929,0.059,0.019,0.01,4256.966,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-23",5,4.23,919.79,,0.002,0.001,394.531,0.059,0.074,0.0328,6636.784,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-24",8,7.38,1767.36,,0.004,0.001,719.744,0.059,0.082,0.0241,12110.072,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-25",24,24,6442,,0.013,0.001,2559.9,0.059,0.178,0.0083,43077.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-26",24,24,6335,,0.013,0.001,2556.7,0.059,0.188,0.0088,43025.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-27",18,16.3,4213.4,,0.009,0.001,1695.256,0.059,0.172,0.0215,28526.576,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-28",24,24,6084,,0.012,0.001,2433,0.059,0.183,0.009,40941.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-02-29",3,2.02,457.22,,0.001,0.001,185.784,0.059,0.014,0.0293,3126.326,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-01",7,6.18,1536.72,,0.003,0.001,627.708,0.059,0.098,0.0351,10562.034,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-02",22,20.41,5226.41,,0.011,0.001,2132.701,0.059,0.218,0.0178,35891.79,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-03",21,20.53,4994.53,,0.01,0.001,2050.941,0.059,0.208,0.0151,34511.777,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-04",22,20.64,5257.41,,0.011,0.001,2134.551,0.059,0.224,0.0175,35916.899,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-05",24,24,6073,,0.012,0.001,2441.4,0.059,0.185,0.009,41080.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-06",24,24,6005,,0.012,0.001,2412.4,0.059,0.183,0.009,40595.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-07",12,11.75,2915.62,,0.006,0.001,1189.215,0.059,0.129,0.0178,20007.981,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-08",20,19.55,4955.45,,0.01,0.001,2030.15,0.059,0.219,0.0178,34160.595,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-09",24,24,6320,,0.013,0.001,2530.1,0.059,0.181,0.0085,42575.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-10",24,24,6696,,0.013,0.001,2661,0.059,0.185,0.0083,44777.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-11",24,24,6221,,0.013,0.001,2493.7,0.059,0.164,0.0078,41960.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-12",24,24,6773,,0.014,0.001,2701,0.059,0.182,0.008,45453.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-13",24,24,6240,,0.013,0.001,2489.6,0.059,0.18,0.0086,41892,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-14",24,24,6625,,0.013,0.001,2661.8,0.059,0.2,0.0089,44791,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-15",18,17.06,4520.92,,0.009,0.001,1826.596,0.059,0.19,0.0193,30736.682,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-16",24,24,6934,,0.014,0.001,2760.2,0.059,0.191,0.0082,46445.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-17",24,24,6260,,0.013,0.001,2501,0.059,0.185,0.0088,42082.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-18",24,24,6544,,0.013,0.001,2598,0.059,0.196,0.009,43715.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-19",24,24,6095,,0.012,0.001,2447.4,0.059,0.185,0.009,41184.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-20",24,24,6116,,0.012,0.001,2459,0.059,0.182,0.0088,41377.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-21",12,11.38,2682.96,,0.006,0.001,1130.53,0.059,0.137,0.0233,19022.62,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-22",18,17,4272.25,,0.009,0.001,1765.947,0.059,0.17,0.0185,29716.811,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-23",16,15.19,3357.13,,0.007,0.001,1391.265,0.059,0.13,0.0152,23410.937,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-24",24,24,6118,,0.012,0.001,2466.5,0.059,0.186,0.009,41504.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-25",13,12.2,3022.44,,0.006,0.001,1227.98,0.059,0.132,0.0179,20662.286,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-26",15,14.24,3310.76,,0.007,0.001,1367,0.059,0.137,0.0162,23000.048,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-27",13,12.65,2972.05,,0.006,0.001,1254.408,0.059,0.183,0.0271,21107.749,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-28",15,13.62,3351.52,,0.007,0.001,1396.344,0.059,0.147,0.0215,23495.474,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-29",3,2.9,727.3,,0.001,0.001,292.21,0.059,0.024,0.01,4917.96,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-03-31",7,6.32,1292.12,,0.003,0.001,548.364,0.059,0.087,0.036,9227.096,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-01",24,24,6065,,0.012,0.001,2435.9,0.059,0.183,0.0089,40986.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-02",2,1.17,282.17,,0.001,0.001,115.122,0.059,0.01,0.018,1937.776,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-03",7,6.34,1358.08,,0.003,0.001,571.222,0.059,0.084,0.0254,9613.032,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-04",24,23.87,6507.52,,0.013,0.001,2604.289,0.059,0.232,0.0128,43820.052,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-05",24,24,6478,,0.013,0.001,2576.1,0.059,0.194,0.009,43345.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-06",24,24,6420,,0.013,0.001,2552.2,0.059,0.19,0.0088,42943.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-07",24,24,6343,,0.013,0.001,2520.4,0.059,0.186,0.0088,42410.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-08",8,6.93,1857.44,,0.004,0.001,758.052,0.059,0.09,0.0235,12756.256,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-09",24,24,6683,,0.013,0.001,2643.5,0.059,0.195,0.0088,44479,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-10",24,24,6278,,0.013,0.001,2497.3,0.059,0.183,0.0087,42020,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-11",14,12.19,2786.24,,0.006,0.001,1181.532,0.059,0.157,0.0321,19879.185,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-12",11,10.68,2674.96,,0.005,0.001,1086.048,0.059,0.12,0.0204,18276.196,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-13",24,24,5965,,0.012,0.001,2387.3,0.059,0.172,0.0086,40173.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-14",24,24,6024,,0.012,0.001,2405.7,0.059,0.172,0.0085,40483.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-15",21,19.43,4393.71,,0.009,0.001,1833.518,0.059,0.183,0.022,30850.431,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-16",16,14.9,3521.15,,0.007,0.001,1477.94,0.059,0.151,0.0165,24872.305,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-17",10,8.1,1913.52,,0.004,0.001,787.549,0.059,0.097,0.0292,13251.355,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-18",12,11.7,2514.1,,0.006,0.001,1114.43,0.059,0.138,0.0211,18753.93,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-19",9,7.64,1865.62,,0.004,0.001,766.76,0.059,0.099,0.0277,12901.878,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-20",8,6.56,1547.35,,0.003,0.001,641.255,0.059,0.094,0.0289,10790.864,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-21",6,5.3,1219.17,,0.003,0.001,509.903,0.059,0.096,0.0335,8579.627,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-22",7,6.58,1624.48,,0.003,0.001,667.032,0.059,0.094,0.0289,11224.446,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-23",10,8.88,1982.61,,0.004,0.001,833.3,0.059,0.098,0.0287,14020.982,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-24",22,21.56,4927.34,,0.01,0.001,2035.746,0.059,0.222,0.0167,34255.938,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-25",12,12,2562,,0.006,0.001,1122,0.059,0.176,0.0264,18879.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-26",11,9.82,2387.03,,0.005,0.001,982.699,0.059,0.105,0.023,16532.979,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-27",21,19.47,4341.32,,0.009,0.001,1830.502,0.059,0.171,0.0168,30800.447,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-28",15,13.93,3108.35,,0.007,0.001,1313.999,0.059,0.172,0.0249,22110.884,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-29",12,11.23,2261.65,,0.005,0.001,972.834,0.059,0.14,0.0223,16370.598,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-04-30",2,1.3,275.8,,0.001,0.001,114.58,0.059,0.009,0.0135,1928.79,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-06",6,5.06,322.72,,0.001,0.001,281.74,0.059,0.134,0.0595,4740.148,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-07",7,3.79,202.14,,0.001,0.001,190.875,0.059,0.113,0.0729,3212.422,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-08",7,5.61,1158.78,,0.003,0.001,512.159,0.059,0.125,0.0571,8617.199,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-09",2,1.72,452,,0.001,0.001,178.444,0.059,0.014,0.0095,3003.068,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-10",15,14.03,3382,,0.007,0.001,1384.363,0.0591,0.134,0.0161,23296.493,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-11",14,13.97,3507.7,,0.007,0.001,1414.85,0.059,0.114,0.011,23806.903,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-12",11,10.78,2648.88,,0.005,0.001,1076.342,0.059,0.108,0.0172,18111.122,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-13",2,1.07,239.26,,0,0.001,97.999,0.059,0.012,0.066,1649.17,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-15",11,10.03,2375,,0.005,0.001,969.778,0.059,0.126,0.0223,16316.26,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-16",9,7.16,1597.92,,0.003,0.001,657.936,0.059,0.086,0.0269,11070.445,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-17",13,12.5,2642,,0.006,0.001,1115.7,0.059,0.138,0.0232,18775.25,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-18",24,24,5607,,0.011,0.001,2258.3,0.059,0.17,0.009,37998.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-19",13,11.28,2575.25,,0.005,0.001,1057.278,0.059,0.11,0.0141,17793.247,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-20",1,0.93,172.98,,0,0.001,70.68,0.059,0.008,0.013,1189.749,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-21",6,5.78,1267.94,,0.003,0.001,522.238,0.059,0.077,0.0302,8787.716,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-22",14,12.87,3126.98,,0.006,0.001,1281.098,0.059,0.116,0.018,21554.268,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-23",24,24,6319,,0.013,0.001,2497.5,0.059,0.182,0.0087,42029.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-24",24,24,5982,,0.012,0.001,2453.3,0.059,0.162,0.0079,41283.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-25",14,12.91,3189.5,,0.007,0.001,1299.439,0.059,0.121,0.0168,21865.932,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-26",18,17.05,4119.6,,0.009,0.001,1706.338,0.059,0.15,0.0153,28716.488,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-27",16,14.75,3559.75,,0.007,0.001,1463.225,0.059,0.148,0.0214,24624.915,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-28",10,9.33,2031.17,,0.004,0.001,877.257,0.059,0.145,0.0281,14760.133,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-29",7,6.82,1666.04,,0.003,0.001,682.86,0.059,0.096,0.0281,11490.858,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-06-30",14,12.6,2984.1,,0.006,0.001,1228.726,0.059,0.127,0.0278,20674.674,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-01",11,10.59,2505.12,,0.005,0.001,1035.437,0.059,0.104,0.0175,17421.613,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-02",4,3.52,847.92,,0.002,0.001,342.888,0.059,0.024,0.009,5770.14,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-05",7,5.57,1152.91,,0.002,0.001,482.908,0.059,0.103,0.0424,8124.308,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-06",12,11.05,2452.05,,0.005,0.001,1002.765,0.0591,0.117,0.019,16874.45,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-07",24,24,5608,,0.012,0.001,2290.3,0.059,0.17,0.0088,38538.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-08",24,24,5743,,0.012,0.001,2360.1,0.059,0.173,0.0087,39715.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-09",24,24,5861,,0.012,0.001,2395.9,0.059,0.17,0.0084,40315.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-10",24,24,5484,,0.011,0.001,2216.2,0.059,0.159,0.0085,37290.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-11",24,24,6122,,0.013,0.001,2501.7,0.059,0.178,0.0085,42097.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-12",24,24,5855,,0.012,0.001,2405.1,0.059,0.17,0.0084,40468.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-13",24,24,6031,,0.012,0.001,2455.2,0.059,0.173,0.0084,41315.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-14",24,24,5398,,0.011,0.001,2180.9,0.059,0.147,0.008,36701,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-15",13,11.96,2756.53,,0.006,0.001,1129.103,0.059,0.109,0.0156,18998.381,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-16",24,24,6031,,0.012,0.001,2468.9,0.059,0.182,0.0088,41545.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-17",24,24,5869,,0.012,0.001,2398.7,0.059,0.18,0.0089,40360.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-18",24,24,5859,,0.012,0.001,2404.2,0.059,0.169,0.0084,40458.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-19",16,15.85,3654.6,,0.008,0.001,1517.885,0.059,0.102,0.008,25540.61,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-20",10,9.67,2233.9,,0.005,0.001,904.658,0.059,0.098,0.0211,15223.491,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-21",24,24,5896,,0.012,0.001,2410.2,0.059,0.163,0.008,40551.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-22",24,24,5557,,0.012,0.001,2293.2,0.059,0.163,0.0084,38588.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-23",24,24,5600,,0.012,0.001,2313.1,0.059,0.152,0.0078,38922.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-24",24,24,5679,,0.012,0.001,2323.2,0.059,0.153,0.0078,39091.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-25",24,24,5910,,0.012,0.001,2427,0.059,0.179,0.0088,40838.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-26",24,24,5943,,0.012,0.001,2428.8,0.059,0.179,0.0088,40874.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-27",24,24,5660,,0.012,0.001,2279.5,0.059,0.155,0.0081,38363.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-28",24,24,5642,,0.011,0.001,2275.1,0.059,0.155,0.0081,38289.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-29",24,24,5973,,0.012,0.001,2385.1,0.059,0.161,0.008,40133.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-30",24,24,6034,,0.012,0.001,2413.4,0.059,0.154,0.0076,40611,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-07-31",24,24,5866,,0.012,0.001,2350.1,0.059,0.159,0.008,39547.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-01",24,24,5393,,0.011,0.001,2189.8,0.059,0.147,0.008,36848.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-02",24,24,5374,,0.011,0.001,2178.9,0.059,0.147,0.008,36657.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-03",24,24,5344,,0.011,0.001,2171.8,0.059,0.147,0.008,36545.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-04",24,24,5871,,0.012,0.001,2428.7,0.059,0.163,0.008,40869.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-05",11,10.21,2227.8,,0.005,0.001,927.603,0.059,0.105,0.0188,15609.941,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-06",24,24,5708,,0.012,0.001,2377.1,0.059,0.16,0.008,39999.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-07",24,24,5916,,0.012,0.001,2469.2,0.059,0.172,0.0083,41550.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-08",24,24,5667,,0.012,0.001,2345.3,0.059,0.156,0.0079,39469.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-09",24,24,5807,,0.012,0.001,2377.4,0.059,0.16,0.008,40003,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-10",24,24,6011,,0.012,0.001,2459.5,0.059,0.167,0.0081,41382.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-11",24,24,6032,,0.012,0.001,2475.6,0.059,0.167,0.008,41657.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-12",24,24,5830,,0.012,0.001,2359.6,0.059,0.159,0.008,39702.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-13",24,24,6185,,0.013,0.001,2481.7,0.059,0.167,0.008,41764.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-14",24,24,6637,,0.013,0.001,2671.9,0.059,0.18,0.008,44960.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-15",24,24,6553,,0.013,0.001,2641,0.059,0.178,0.008,44443.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-16",24,24,6376,,0.013,0.001,2573.7,0.059,0.173,0.008,43307,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-17",24,24,6634,,0.013,0.001,2673,0.059,0.181,0.008,44976.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-18",24,24,6659,,0.014,0.001,2692.2,0.059,0.18,0.008,45300.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-19",24,24,6620,,0.013,0.001,2659.5,0.059,0.177,0.0079,44748.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-20",24,24,6506,,0.013,0.001,2607.3,0.059,0.172,0.0078,43875.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-21",24,24,6447,,0.013,0.001,2589.7,0.059,0.172,0.0079,43577.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-22",24,24,6129,,0.012,0.001,2453,0.059,0.164,0.008,41273.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-23",24,24,6189,,0.013,0.001,2492.4,0.059,0.168,0.008,41940.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-24",24,24,6587,,0.013,0.001,2663.3,0.059,0.179,0.008,44815.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-25",24,24,6325,,0.013,0.001,2533.3,0.059,0.171,0.008,42625.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-26",24,24,5619,,0.011,0.001,2260.2,0.059,0.153,0.008,38034.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-27",24,24,6099,,0.012,0.001,2446.2,0.059,0.165,0.008,41167.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-28",24,24,6382,,0.013,0.001,2551.6,0.059,0.172,0.008,42934.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-29",24,24,6073,,0.013,0.001,2503.8,0.059,0.169,0.008,42130.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-30",24,24,5963,,0.012,0.001,2464.1,0.059,0.166,0.008,41463.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-08-31",24,24,5915,,0.012,0.001,2405.2,0.059,0.163,0.008,40471.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-01",24,24,5947,,0.012,0.001,2455.2,0.059,0.165,0.008,41312.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-02",24,24,5161,,0.011,0.001,2116.6,0.059,0.142,0.008,35618.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-03",24,24,6126,,0.012,0.001,2462.2,0.059,0.167,0.008,41432.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-04",24,24,6054,,0.012,0.001,2436.2,0.059,0.165,0.008,40993.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-05",24,24,5722,,0.012,0.001,2319.9,0.059,0.156,0.008,39037,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-06",24,24,5706,,0.012,0.001,2333.4,0.059,0.155,0.0079,39262.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-07",24,24,5698,,0.012,0.001,2297.6,0.059,0.145,0.0075,38662.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-08",24,24,5135,,0.011,0.001,2088.4,0.059,0.14,0.008,35139.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-09",14,12.87,2755.92,,0.006,0.001,1140.606,0.059,0.101,0.0144,19191.745,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-10",9,8.15,1524.12,,0.003,0.001,645.884,0.059,0.078,0.0188,10868.625,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-11",24,24,5894,,0.012,0.001,2418.3,0.059,0.163,0.008,40694.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-12",24,24,6015,,0.013,0.001,2500.3,0.059,0.168,0.008,42074.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-13",24,24,5899,,0.012,0.001,2433.5,0.059,0.164,0.008,40951.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-14",24,24,5650,,0.012,0.001,2283.2,0.059,0.154,0.008,38419.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-15",24,24,5593,,0.011,0.001,2268,0.059,0.152,0.008,38166.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-16",24,24,5913,,0.012,0.001,2378.3,0.059,0.156,0.0078,40015.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-17",24,24,6029,,0.012,0.001,2416.2,0.059,0.161,0.0079,40658.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-18",24,24,5912,,0.012,0.001,2373.8,0.059,0.157,0.0078,39942.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-19",13,11.1,2523.2,,0.005,0.001,1036.468,0.059,0.108,0.0239,17440.824,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-20",24,24,5750,,0.012,0.001,2346.8,0.059,0.152,0.0077,39490.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-21",13,12.28,2929.26,,0.006,0.001,1186.421,0.059,0.123,0.0172,19962.299,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-22",24,24,6028,,0.012,0.001,2410.4,0.059,0.151,0.0075,40559.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-23",20,19.09,4605.16,,0.009,0.001,1870.77,0.059,0.138,0.0106,31478.351,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-24",12,10.72,2549.28,,0.005,0.001,1036.807,0.059,0.098,0.017,17446.35,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-26",9,8.03,1567,,0.003,0.001,651.363,0.0591,0.093,0.0232,10958.684,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-27",10,9.41,2304.59,,0.005,0.001,937.809,0.059,0.094,0.0164,15780.695,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-28",20,18.61,4687.85,,0.01,0.001,1889.884,0.059,0.157,0.0139,31798.104,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-29",19,17.61,4467.59,,0.009,0.001,1805.962,0.059,0.163,0.0149,30391.592,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-09-30",24,24,6415,,0.013,0.001,2558.1,0.059,0.19,0.0088,43045,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-01",24,24,6108,,0.012,0.001,2443.3,0.059,0.144,0.007,41113.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-02",24,24,6481,,0.013,0.001,2572.6,0.059,0.159,0.0073,43282.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-03",16,15.35,3684.63,,0.008,0.001,1497.443,0.059,0.105,0.0108,25199.02,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-04",10,8.38,1943.38,,0.004,0.001,798.179,0.0591,0.079,0.0185,13428.708,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-05",15,14.03,3398.41,,0.007,0.001,1382.02,0.059,0.105,0.0123,23259.743,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-06",16,14.85,3861.15,,0.008,0.001,1567.179,0.059,0.127,0.0121,26368.051,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-07",22,20.36,5060.87,,0.01,0.001,2059.08,0.059,0.161,0.0136,34648.702,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-08",2,1.27,234.54,,0.001,0.001,102.917,0.059,0.007,0.0115,1731.157,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-11",1,0.03,0,,0,0.001,0.381,0.059,0,0.029,6.408,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-12",10,9.97,2332.39,,0.005,0.001,960.582,0.059,0.123,0.022,16159.555,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-13",24,24,5757,,0.012,0.001,2347.7,0.059,0.146,0.0075,39505.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-14",24,24,5754,,0.012,0.001,2343.1,0.059,0.134,0.0068,39424.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-15",24,24,6284,,0.013,0.001,2535.4,0.059,0.141,0.0066,42660.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-16",24,24,5721,,0.012,0.001,2320.5,0.059,0.136,0.007,39048,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-17",24,24,6358,,0.013,0.001,2557.6,0.059,0.147,0.0068,43031.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-18",24,24,6037,,0.012,0.001,2465.2,0.059,0.131,0.0063,41485.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-19",24,24,6057,,0.012,0.001,2446.6,0.059,0.134,0.0065,41163.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-20",24,24,6103,,0.012,0.001,2460.9,0.059,0.138,0.0067,41406.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-21",24,24,6083,,0.012,0.001,2473.3,0.059,0.14,0.0068,41619.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-22",19,18.55,4696,,0.01,0.001,1895.83,0.059,0.097,0.0076,31901.74,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-23",24,24,6234,,0.013,0.001,2513.7,0.059,0.16,0.0076,42298.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-24",24,24,6161,,0.012,0.001,2466.6,0.059,0.136,0.0065,41505.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-25",24,24,6148,,0.013,0.001,2489,0.059,0.128,0.0061,41882,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-26",24,24,5986,,0.012,0.001,2400.7,0.059,0.136,0.0068,40393.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-27",24,24,6216,,0.013,0.001,2481.5,0.059,0.135,0.0065,41758.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-28",24,24,6099,,0.012,0.001,2446.8,0.059,0.136,0.0066,41164.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-29",24,24,5659,,0.012,0.001,2283.1,0.059,0.133,0.0069,38416.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-30",24,24,5704,,0.012,0.001,2295.3,0.059,0.112,0.0059,38626.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-10-31",24,24,5550,,0.011,0.001,2245.2,0.059,0.097,0.0052,37780.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-01",24,24,6070,,0.012,0.001,2444.6,0.059,0.132,0.0064,41133.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-02",24,24,6416,,0.013,0.001,2551.6,0.059,0.131,0.0061,42939.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-03",24,24,6539,,0.013,0.001,2603.5,0.059,0.113,0.0052,43811,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-04",24,24,6163,,0.013,0.001,2482.5,0.059,0.13,0.0062,41771,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-05",24,24,6430,,0.013,0.001,2577.4,0.059,0.145,0.0067,43370.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-06",24,24,6089,,0.012,0.001,2440.1,0.059,0.129,0.0063,41059.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-07",24,24,2704,,0.007,0.001,1354.7,0.059,0.297,0.0603,22798.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-08",24,24,0,,0.003,0.001,498.3,0.0592,0.444,0.106,8386,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-09",24,24,1910,,0.006,0.001,1119.2,0.0591,0.356,0.0769,18838.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-10",24,24,5974,,0.012,0.001,2407.4,0.059,0.127,0.0063,40512.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-11",24,24,6054,,0.012,0.001,2431.7,0.059,0.136,0.0067,40920.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-12",24,24,5919,,0.012,0.001,2383.4,0.059,0.138,0.0069,40108.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-13",24,24,5819,,0.012,0.001,2350,0.059,0.12,0.0061,39546.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-14",17,15.96,3661.36,,0.008,0.001,1536.178,0.059,0.136,0.0164,25847.702,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-15",17,15.85,3722.79,,0.008,0.001,1569.095,0.059,0.136,0.0192,26401.136,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-16",24,24,6146,,0.013,0.001,2494.3,0.059,0.13,0.0062,41970,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-17",24,24,6260,,0.013,0.001,2517.1,0.059,0.128,0.0061,42357.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-18",24,24,6020,,0.012,0.001,2424.1,0.059,0.124,0.0061,40790,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-19",24,24,5501,,0.011,0.001,2249.1,0.059,0.12,0.0064,37847.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-20",24,24,6369,,0.013,0.001,2549.9,0.059,0.138,0.0064,42905.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-21",24,24,5902,,0.012,0.001,2377.6,0.059,0.134,0.0067,40006.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-22",24,24,7202,,0.015,0.001,2886,0.059,0.17,0.007,48564.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-23",24,24,5874,,0.012,0.001,2355.3,0.059,0.139,0.007,39629.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-24",24,24,6230,,0.013,0.001,2495.3,0.059,0.147,0.007,41987.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-25",24,24,6190,,0.013,0.001,2478.2,0.059,0.143,0.0069,41699.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-26",5,4.08,1042.48,,0.002,0.001,414.468,0.059,0.027,0.0218,6974.532,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-27",10,9.72,2429.12,,0.005,0.001,991.628,0.059,0.104,0.0212,16686.988,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-28",17,16.4,3872.28,,0.008,0.001,1601.144,0.059,0.139,0.0144,26944.964,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-29",24,24,6321,,0.013,0.001,2529.7,0.059,0.152,0.0072,42570,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-11-30",24,24,6916,,0.014,0.001,2761.7,0.059,0.163,0.007,46471.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-01",24,24,7089,,0.014,0.001,2831.2,0.059,0.166,0.007,47644.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-02",24,24,6441,,0.013,0.001,2563.1,0.059,0.151,0.007,43129.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-03",24,24,6509,,0.013,0.001,2592.5,0.059,0.152,0.007,43621.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-04",1,0.08,2.72,,0,0.001,3.608,0.059,0.001,0.04,60.72,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-08",5,4.17,834.51,,0.002,0.001,369.467,0.059,0.094,0.0472,6217.51,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-09",24,24,6052,,0.013,0.001,2527.6,0.059,0.148,0.007,42532,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-10",24,24,6098,,0.013,0.001,2546.4,0.059,0.149,0.007,42849.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-11",24,24,6426,,0.013,0.001,2662.2,0.059,0.156,0.007,44797.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-12",24,24,6138,,0.013,0.001,2567.3,0.059,0.15,0.007,43200.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-13",24,24,6169,,0.013,0.001,2594.4,0.059,0.152,0.007,43656,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-14",24,24,6104,,0.013,0.001,2554.7,0.059,0.15,0.007,42990.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-15",24,24,5934,,0.013,0.001,2485.5,0.059,0.145,0.007,41823.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-16",24,24,6504,,0.013,0.001,2623.8,0.059,0.154,0.007,44148.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-17",24,24,6357,,0.013,0.001,2532.5,0.059,0.148,0.007,42616.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-18",24,24,6485,,0.013,0.001,2597.4,0.059,0.152,0.007,43709.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-19",24,24,5896,,0.012,0.001,2377.1,0.059,0.14,0.007,40002,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-20",13,12.43,3122.57,,0.006,0.001,1255.977,0.059,0.103,0.0144,21134.097,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-21",24,24,6068,,0.012,0.001,2431,0.059,0.143,0.007,40905.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-22",24,24,5974,,0.012,0.001,2400.9,0.059,0.141,0.007,40398.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-23",24,24,6241,,0.013,0.001,2501.9,0.059,0.141,0.0067,42098.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-24",24,24,6491,,0.013,0.001,2580,0.059,0.142,0.0065,43411.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-25",24,24,6092,,0.012,0.001,2447.2,0.059,0.133,0.0065,41179,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-26",16,15.18,3454.34,,0.007,0.001,1454.821,0.059,0.14,0.0182,24477.057,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-27",24,24,6205,,0.013,0.001,2485.7,0.059,0.164,0.0078,41829.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-28",24,24,6660,,0.013,0.001,2658.1,0.059,0.162,0.0073,44730.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-29",24,24,5866,,0.012,0.001,2358.5,0.059,0.146,0.0073,39687.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-30",24,24,5940,,0.012,0.001,2388.2,0.059,0.141,0.007,40185.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"1",,"2020-12-31",24,24,5908,,0.012,0.001,2381.2,0.059,0.14,0.007,40068.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-01",5,4.27,919.49,,0.002,0.001,376.565,0.059,0.029,0.0112,6335.016,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-02",12,11.72,2737.64,,0.006,0.001,1128.584,0.059,0.127,0.0197,18992.944,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-03",24,24,5947,,0.012,0.001,2409.9,0.059,0.174,0.0086,40551.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-04",13,11.48,2562.09,,0.005,0.001,1063.935,0.0591,0.111,0.0207,17902.153,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-05",18,16.41,4052.72,,0.008,0.001,1666.121,0.059,0.143,0.0124,28035.38,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-06",24,24,5920,,0.012,0.001,2383.3,0.059,0.174,0.0087,40102.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-07",24,24,6170,,0.013,0.001,2480.3,0.059,0.176,0.0084,41735.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-08",14,12.52,2943.02,,0.006,0.001,1213.726,0.059,0.11,0.0246,20424.394,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-09",24,24,6263,,0.013,0.001,2527.6,0.059,0.174,0.0082,42533.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-10",24,24,6106,,0.012,0.001,2460,0.059,0.174,0.0084,41393.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-11",15,13.97,3062.11,,0.006,0.001,1268.964,0.059,0.123,0.0161,21353.302,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-12",11,10.18,2256.79,,0.005,0.001,936.995,0.059,0.105,0.0225,15765.241,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-13",24,24,6000,,0.012,0.001,2437.1,0.059,0.172,0.0084,41004.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-14",24,24,5902,,0.012,0.001,2394.1,0.059,0.17,0.0085,40281,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-15",24,24,6135,,0.012,0.001,2468.2,0.059,0.177,0.0085,41532,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-16",24,24,6116,,0.012,0.001,2468.2,0.059,0.175,0.0085,41532,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-17",24,24,6009,,0.012,0.001,2423.5,0.059,0.176,0.0087,40782.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-18",21,19.99,4658.74,,0.01,0.001,1904.027,0.059,0.149,0.0109,32038.971,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-19",12,11.27,2701.83,,0.006,0.001,1160.202,0.059,0.114,0.019,19524.389,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-20",24,24,6291,,0.014,0.001,2680.1,0.059,0.18,0.008,45096,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-21",24,24,6176,,0.013,0.001,2569.6,0.059,0.179,0.0083,43243.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-22",24,24,5697,,0.012,0.001,2286.4,0.059,0.162,0.0085,38479,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-23",20,18.45,4537.56,,0.009,0.001,1862.152,0.059,0.157,0.0147,31340.079,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-24",3,2.3,534,,0.001,0.001,223.69,0.059,0.016,0.0097,3765.49,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-25",7,6.83,1596.42,,0.003,0.001,662.28,0.059,0.105,0.028,11144.637,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-26",10,9.3,2015.39,,0.004,0.001,837.914,0.059,0.099,0.023,14098.439,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-27",24,24,5351,,0.011,0.001,2174.7,0.059,0.149,0.0081,36590.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-28",19,18.08,4166.84,,0.009,0.001,1710.576,0.059,0.141,0.0127,28786.504,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-29",11,7.64,1718.87,,0.004,0.001,719.011,0.059,0.09,0.0303,12098.444,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-30",20,19.85,4796,,0.01,0.001,1952.5,0.059,0.163,0.0126,32857.685,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-01-31",17,16.43,4038.78,,0.008,0.001,1651.634,0.059,0.157,0.0155,27792.51,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-01",12,11.17,2424.43,,0.005,0.001,1007.982,0.059,0.108,0.0169,16961.49,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-02",8,6.23,1408.11,,0.003,0.001,592.97,0.0591,0.101,0.0368,9978.424,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-03",13,11.26,2580.28,,0.005,0.001,1083.04,0.0591,0.134,0.0222,18222.564,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-04",18,17.28,4306.6,,0.009,0.001,1760.921,0.059,0.144,0.0114,29631.469,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-05",19,18.1,4437.38,,0.009,0.001,1816.336,0.059,0.145,0.0113,30559.35,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-06",18,17.27,4220.8,,0.009,0.001,1736.499,0.059,0.141,0.0111,29218.449,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-07",16,15.34,3504.32,,0.007,0.001,1443.896,0.059,0.13,0.0141,24297.018,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-08",2,1.38,309.1,,0.001,0.001,132.176,0.059,0.01,0.0105,2224.224,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-09",6,5.53,1260.03,,0.003,0.001,526.624,0.059,0.1,0.0417,8860.786,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-10",19,18.07,4449.71,,0.009,0.001,1816.584,0.059,0.147,0.0115,30564.362,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-11",19,18.1,4481.2,,0.009,0.001,1833.505,0.059,0.156,0.0125,30855.985,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-12",20,18.9,4703.2,,0.01,0.001,1919.95,0.059,0.157,0.0126,32307.83,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-13",19,18.17,4486.97,,0.009,0.001,1833.633,0.059,0.15,0.0116,30855.449,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-14",19,17.69,4379.12,,0.009,0.001,1788.874,0.059,0.151,0.0153,30104.984,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-15",17,16.63,4166.66,,0.009,0.001,1711.524,0.059,0.155,0.0133,28798.731,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-16",10,8.98,2075.98,,0.004,0.001,866.452,0.059,0.104,0.0212,14581.642,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-17",16,15.07,3350.3,,0.007,0.001,1371.068,0.059,0.132,0.0148,23071.216,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-18",18,17.03,4200.11,,0.009,0.001,1708.134,0.0591,0.148,0.0162,28742.224,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-19",17,15.85,3975.01,,0.008,0.001,1620.715,0.059,0.151,0.0164,27275.109,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-20",19,18.18,4530.46,,0.009,0.001,1854.292,0.059,0.148,0.0121,31204.015,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-21",24,24,5880,,0.012,0.001,2371.4,0.059,0.16,0.008,39899.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-22",1,0.97,220.19,,0,0.001,90.695,0.059,0.008,0.01,1525.519,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-24",9,8.9,1969.7,,0.004,0.001,821.17,0.059,0.119,0.025,13817.57,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-25",19,18.55,4542.01,,0.009,0.001,1844.5,0.059,0.154,0.0125,31038.278,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-26",19,18.12,4433.01,,0.009,0.001,1817.904,0.059,0.15,0.0125,30589.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-27",19,18.1,4425.8,,0.009,0.001,1813.07,0.059,0.157,0.0149,30510.08,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-28",24,24,5792,,0.012,0.001,2337.9,0.059,0.174,0.0088,39336,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-02-29",2,1.27,224.03,,0,0.001,97.008,0.059,0.008,0.0135,1632.79,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-01",8,7.87,1892.73,,0.004,0.001,785.665,0.059,0.105,0.0243,13219.727,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-02",17,16.35,4056.98,,0.008,0.001,1659.823,0.059,0.149,0.0145,27927.713,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-03",18,16.5,3868.22,,0.008,0.001,1584.248,0.059,0.129,0.0181,26657.26,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-04",18,17.37,4254.31,,0.009,0.001,1740.686,0.059,0.142,0.0121,29292.302,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-05",24,24,5781,,0.012,0.001,2345.6,0.059,0.175,0.0089,39470.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-06",19,18.07,4409.7,,0.009,0.001,1792.59,0.059,0.15,0.0117,30162.435,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-07",11,9.37,2155.31,,0.004,0.001,888.199,0.059,0.106,0.0213,14946.65,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-08",17,16.14,3953.08,,0.008,0.001,1629.46,0.059,0.151,0.0149,27418.248,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-09",20,18.77,4647.83,,0.01,0.001,1895.228,0.059,0.155,0.0131,31891.479,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-10",24,24,6391,,0.013,0.001,2571,0.059,0.167,0.0077,43261.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-11",24,24,5946,,0.012,0.001,2402.9,0.059,0.157,0.0077,40436.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-12",24,24,6458,,0.013,0.001,2603.9,0.059,0.176,0.008,43815.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-13",18,17.33,4313.85,,0.009,0.001,1756.366,0.059,0.144,0.0127,29553.203,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-14",20,18.99,4848.46,,0.01,0.001,1979.023,0.059,0.171,0.0132,33305.476,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-15",17,16.28,4112.63,,0.008,0.001,1679.853,0.059,0.148,0.0132,28265.691,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-16",24,24,6542,,0.013,0.001,2647.3,0.059,0.195,0.0088,44545.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-17",24,24,5944,,0.012,0.001,2399.8,0.059,0.18,0.0089,40378.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-18",24,24,6172,,0.013,0.001,2481.8,0.059,0.184,0.0088,41761.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-19",20,18.26,4504.84,,0.009,0.001,1834.557,0.0591,0.163,0.0123,30868.448,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-20",24,24,5835,,0.012,0.001,2364.5,0.059,0.161,0.0081,39785.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-21",10,8.73,1650.66,,0.004,0.001,735.869,0.059,0.129,0.0307,12383.028,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-22",15,14.3,3540.64,,0.007,0.001,1457.826,0.059,0.128,0.0135,24528.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-23",8,8,1664,,0.003,0.001,683.6,0.059,0.051,0.0089,11503.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-24",21,20.47,4790.8,,0.01,0.001,1959.76,0.059,0.191,0.0163,32978.565,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-25",16,14.86,3384.12,,0.007,0.001,1419.296,0.059,0.161,0.0226,23881.884,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-26",14,12.69,2859.36,,0.006,0.001,1177.276,0.059,0.127,0.0242,19806.49,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-27",10,8.77,2045.28,,0.004,0.001,850.818,0.059,0.096,0.0249,14317.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-28",11,10.03,2408.73,,0.005,0.001,1006.815,0.059,0.105,0.0199,16941.179,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-29",2,1.57,359.33,,0.001,0.001,154.351,0.059,0.012,0.01,2596.659,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-02",7,6.05,1334,,0.003,0.001,557.4,0.059,0.095,0.0313,9376.895,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-03",24,24,5844,,0.012,0.001,2365.7,0.059,0.17,0.0086,39805,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-04",24,24,6281,,0.013,0.001,2546,0.059,0.191,0.0089,42841,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-05",13,12.09,2908.88,,0.006,0.001,1192.924,0.059,0.119,0.0155,20075.242,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-06",24,24,6090,,0.012,0.001,2451.4,0.059,0.183,0.0089,41246.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-07",24,24,6003,,0.012,0.001,2415.4,0.059,0.179,0.0088,40642.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-08",24,24,6588,,0.013,0.001,2666.8,0.059,0.196,0.0088,44874.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-09",24,24,6300,,0.013,0.001,2533.1,0.059,0.19,0.0089,42625.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-10",24,24,5955,,0.012,0.001,2398.2,0.059,0.17,0.0084,40354.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-11",2,1.02,215.06,,0,0.001,88.428,0.059,0.009,0.07,1487.396,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-12",7,6.48,1435.6,,0.003,0.001,607.244,0.059,0.099,0.0341,10218.896,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-13",24,24,5696,,0.012,0.001,2297.6,0.059,0.163,0.0085,38661.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-14",24,24,5746,,0.012,0.001,2312.1,0.059,0.158,0.0081,38903,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-15",15,13.97,3090.33,,0.006,0.001,1266.589,0.059,0.114,0.0153,21312.896,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-16",12,10.92,2580.62,,0.005,0.001,1065.53,0.059,0.111,0.0195,17928.72,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-17",5,3.73,663.94,,0.001,0.001,290.996,0.059,0.063,0.0388,4898.373,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-19",5,4.92,1061.44,,0.002,0.001,442.092,0.059,0.08,0.0328,7439.384,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-20",6,4.45,897.42,,0.002,0.001,392.326,0.059,0.069,0.0348,6602.587,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-23",5,4.65,901.6,,0.002,0.001,386.375,0.059,0.079,0.0382,6502.65,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-24",19,17.53,3907.28,,0.008,0.001,1615.667,0.059,0.132,0.0131,27188.857,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-25",9,8.5,1901,,0.004,0.001,798.25,0.059,0.09,0.0248,13430.25,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-26",1,0.73,108.77,,0,0.001,52.414,0.059,0.007,0.016,882.205,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-28",10,9.93,2199.75,,0.005,0.001,915.433,0.059,0.124,0.0224,15402.591,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-29",9,7.88,1491.39,,0.003,0.001,633.902,0.059,0.08,0.0209,10667.516,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-04-30",8,6.9,1237.16,,0.003,0.001,537.08,0.059,0.065,0.0218,9037.044,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-08",11,10.35,2142.2,,0.005,0.001,966.11,0.059,0.162,0.0364,16258.25,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-09",1,0.77,164.01,,0,0.001,72.611,0.059,0.005,0.009,1222.067,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-10",12,11.85,2863.4,,0.006,0.001,1176.025,0.059,0.121,0.0171,19788.51,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-11",24,24,5961,,0.012,0.001,2447.5,0.059,0.171,0.0083,41182.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-12",10,9.42,2224.97,,0.005,0.001,912.465,0.059,0.098,0.0188,15356.594,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-13",6,4.65,956.7,,0.002,0.001,423.096,0.059,0.073,0.0325,7118.69,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-14",7,6.65,1568.3,,0.003,0.001,644.25,0.059,0.079,0.0244,10840.19,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-15",8,7.08,1649.24,,0.003,0.001,680.016,0.059,0.074,0.0204,11441.548,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-16",6,4.89,963.63,,0.002,0.001,410.984,0.059,0.064,0.0337,6913.281,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-17",10,9.35,1954.55,,0.004,0.001,809.455,0.059,0.099,0.0252,13621.14,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-18",16,14.51,3337.16,,0.007,0.001,1366.336,0.059,0.123,0.0149,22990.665,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-19",14,12.59,2720.03,,0.006,0.001,1117.025,0.0591,0.108,0.0168,18797.157,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-20",7,5.99,1329.49,,0.003,0.001,556.226,0.059,0.082,0.0293,9360.353,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-21",24,24,5658,,0.012,0.001,2330.5,0.059,0.172,0.0088,39211.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-22",24,24,5969,,0.012,0.001,2447.5,0.059,0.17,0.0083,41183.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-23",24,24,6122,,0.012,0.001,2440.1,0.059,0.173,0.0084,41064.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-24",11,10.2,2501.2,,0.005,0.001,1037.49,0.059,0.094,0.0136,17457.88,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-25",11,9.78,2329.8,,0.005,0.001,960.528,0.059,0.089,0.017,16160.678,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-26",12,11.46,2813.84,,0.006,0.001,1165.634,0.059,0.101,0.0126,19611.323,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-27",11,10.15,2454.7,,0.005,0.001,1003.931,0.059,0.107,0.0217,16894.53,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-28",2,1.03,211.27,,0,0.001,85.669,0.059,0.008,0.063,1442.226,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-06-30",10,9.93,2314.33,,0.005,0.001,958.438,0.059,0.121,0.0219,16126.441,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-01",11,9.26,2122.36,,0.004,0.001,877.97,0.059,0.096,0.0231,14777.447,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-02",4,3.88,893.68,,0.002,0.001,358.748,0.059,0.025,0.0083,6037.876,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-06",9,8.93,1932.56,,0.004,0.001,787.751,0.059,0.111,0.0227,13256.004,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-07",14,13.76,2927.98,,0.006,0.001,1195.262,0.059,0.109,0.0122,20112.234,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-08",11,9.09,1984.09,,0.004,0.001,807.042,0.0591,0.081,0.0276,13577.003,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-09",13,11.47,2638.48,,0.005,0.001,1078.523,0.059,0.104,0.0256,18148.837,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-10",24,24,5346,,0.011,0.001,2162.6,0.059,0.148,0.0081,36392.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-11",13,11.77,2836.78,,0.006,0.001,1175.046,0.059,0.104,0.0158,19771.375,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-12",14,12.64,2826.66,,0.006,0.001,1176.602,0.059,0.107,0.0157,19797.958,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-13",13,12.22,2756.62,,0.006,0.001,1133.23,0.059,0.093,0.0115,19068.546,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-14",24,24,5237,,0.011,0.001,2118.7,0.059,0.137,0.0077,35653.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-15",24,24,5825,,0.012,0.001,2387.5,0.059,0.173,0.0086,40176.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-16",11,10.52,2413.08,,0.005,0.001,982.32,0.059,0.102,0.018,16532.16,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-17",12,11.62,2587.22,,0.005,0.001,1062.029,0.059,0.102,0.0154,17869.785,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-18",12,10.57,2326.27,,0.005,0.001,950.976,0.0591,0.099,0.0243,16001.924,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-19",14,12.84,2801.35,,0.006,0.001,1144.835,0.059,0.097,0.0126,19264.667,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-20",24,24,5712,,0.012,0.001,2339.1,0.059,0.163,0.0083,39362.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-21",13,11.05,2416.02,,0.005,0.001,988.937,0.059,0.1,0.0205,16639.204,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-22",9,8.08,1601.36,,0.003,0.001,674.88,0.059,0.06,0.0143,11355.88,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-23",6,5.8,1172.8,,0.002,0.001,485.04,0.059,0.031,0.0077,8161.56,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-24",9,8.95,2003.3,,0.004,0.001,824.835,0.059,0.087,0.016,13880.395,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-25",13,11.85,2677.45,,0.006,0.001,1109,0.059,0.103,0.0135,18662.22,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-26",14,12.82,2905.49,,0.006,0.001,1195.393,0.059,0.113,0.0146,20115.748,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-27",24,24,5480,,0.011,0.001,2220.6,0.059,0.149,0.008,37368.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-28",24,24,5473,,0.011,0.001,2220.6,0.059,0.149,0.008,37363.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-29",24,24,5762,,0.012,0.001,2319.9,0.059,0.156,0.008,39038.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-30",24,24,5821,,0.012,0.001,2349.9,0.059,0.149,0.0075,39540.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-07-31",24,24,5682,,0.012,0.001,2285.1,0.059,0.154,0.008,38450.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-01",13,11.68,2692.36,,0.006,0.001,1098.986,0.059,0.093,0.0153,18491.67,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-02",24,24,5255,,0.011,0.001,2130.5,0.059,0.143,0.008,35848.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-03",24,24,5225,,0.011,0.001,2123.1,0.059,0.142,0.008,35727.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-04",9,8.88,1938.55,,0.004,0.001,797.229,0.059,0.071,0.0131,13416.273,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-05",24,24,5380,,0.011,0.001,2217.4,0.059,0.148,0.0079,37309.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-06",6,5.27,1058.89,,0.002,0.001,436.098,0.059,0.03,0.0088,7337.072,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-07",8,7.68,1678.88,,0.004,0.001,701.192,0.059,0.074,0.0204,11799.18,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-08",15,14.3,3042.5,,0.006,0.001,1266.51,0.059,0.106,0.0123,21309.793,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-09",12,11.15,2519.9,,0.005,0.001,1042.09,0.059,0.08,0.0109,17534.875,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-10",14,13.17,2979.6,,0.006,0.001,1235.335,0.059,0.098,0.0112,20784.861,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-11",11,10,2276.02,,0.005,0.001,939.925,0.059,0.082,0.0152,15816.15,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-12",17,16.2,3918.27,,0.008,0.001,1611.18,0.059,0.133,0.0127,27109.836,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-13",24,24,6013,,0.012,0.001,2442.4,0.059,0.164,0.008,41095.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-14",24,24,6348,,0.013,0.001,2585.4,0.059,0.165,0.0076,43502.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-15",24,24,6364,,0.013,0.001,2603.3,0.059,0.175,0.008,43804.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-16",24,24,6184,,0.013,0.001,2531.7,0.059,0.17,0.008,42601,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-17",24,24,6402,,0.013,0.001,2628.1,0.059,0.177,0.008,44222.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-18",24,24,6428,,0.013,0.001,2640.2,0.059,0.176,0.0079,44424.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-19",24,24,6345,,0.013,0.001,2590,0.059,0.171,0.0078,43580.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-20",24,24,6215,,0.013,0.001,2519.3,0.059,0.16,0.0075,42392.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-21",24,24,6235,,0.013,0.001,2540.9,0.059,0.166,0.0078,42755.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-22",24,24,5933,,0.012,0.001,2394,0.059,0.159,0.0079,40284.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-23",24,24,5914,,0.012,0.001,2391.9,0.059,0.161,0.008,40250.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-24",24,24,6174,,0.013,0.001,2550.6,0.059,0.172,0.008,42919.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-25",24,24,6015,,0.012,0.001,2443.1,0.059,0.164,0.008,41108.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-26",24,24,5822,,0.012,0.001,2378.7,0.059,0.161,0.008,40021.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-27",24,24,5870,,0.012,0.001,2378.2,0.059,0.16,0.008,40018.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-28",24,23.55,5870.3,,0.012,0.001,2384.74,0.059,0.161,0.0081,40128.545,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-29",11,10.62,2352.2,,0.005,0.001,970.08,0.059,0.088,0.0155,16323.586,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-30",1,0.25,23.75,,0,0.001,15.8,0.059,0.002,0.013,265.85,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-08-31",10,9.88,2176.2,,0.005,0.001,892.376,0.059,0.088,0.0154,15014.272,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-01",10,9.27,2061.5,,0.004,0.001,853.92,0.059,0.086,0.015,14370.487,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-02",13,12.19,2567.25,,0.005,0.001,1061.043,0.059,0.104,0.0155,17856.726,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-03",17,16.21,3723.73,,0.008,0.001,1529.879,0.059,0.13,0.0127,25743.307,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-04",24,24,5990,,0.012,0.001,2419,0.059,0.163,0.008,40700.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-05",24,24,5591,,0.012,0.001,2286.1,0.059,0.154,0.008,38469.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-06",24,24,5756,,0.012,0.001,2354.2,0.059,0.158,0.008,39612.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-07",24,24,6418,,0.013,0.001,2639.8,0.059,0.178,0.008,44418.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-08",24,24,6418,,0.013,0.001,2637,0.059,0.177,0.008,44373.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-09",24,24,5283,,0.011,0.001,2149.1,0.059,0.145,0.008,36164.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-10",24,24,5242,,0.011,0.001,2124.3,0.059,0.143,0.008,35749.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-11",11,9.15,1849.66,,0.004,0.001,772.653,0.059,0.104,0.0314,12998.035,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-12",4,1.67,246.92,,0.001,0.001,114.716,0.059,0.019,0.0723,1930.93,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-13",9,8.03,1770,,0.004,0.001,725.045,0.059,0.079,0.0213,12200.514,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-14",24,24,5469,,0.011,0.001,2218.9,0.059,0.149,0.008,37339.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-15",12,10.97,2581.1,,0.005,0.001,1060.473,0.059,0.096,0.0162,17845.552,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-16",24,24,5677,,0.012,0.001,2296,0.059,0.149,0.0077,38637.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-17",24,23.48,5641.08,,0.012,0.001,2290.964,0.059,0.152,0.008,38551.792,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-18",12,11.1,2629.2,,0.005,0.001,1081.3,0.059,0.093,0.015,18193.84,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-19",22,21.02,5059.1,,0.011,0.001,2090.518,0.059,0.13,0.0149,35180.692,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-20",11,10.95,2510.1,,0.005,0.001,1027.525,0.059,0.097,0.0145,17289.38,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-21",14,13.69,3104,,0.006,0.001,1276.499,0.059,0.113,0.0129,21482.468,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-22",24,24,5757,,0.012,0.001,2321.9,0.059,0.138,0.0071,39070.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-23",24,24,5577,,0.011,0.001,2257.3,0.059,0.137,0.0072,37984.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-24",14,13.2,2980.8,,0.006,0.001,1222.78,0.059,0.094,0.013,20577.66,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-25",7,5.26,872.92,,0.002,0.001,385.999,0.059,0.075,0.041,6494.359,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-26",10,9.85,1923.9,,0.004,0.001,799.84,0.059,0.087,0.0163,13455.595,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-27",12,11.72,2647,,0.005,0.001,1085.9,0.059,0.102,0.0152,18272.708,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-28",24,24,5792,,0.012,0.001,2338.6,0.059,0.163,0.0083,39351.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-29",24,24,5691,,0.012,0.001,2310.1,0.059,0.164,0.0084,38872.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-09-30",24,24,5769,,0.012,0.001,2333.5,0.059,0.167,0.0085,39264.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-01",24,23.2,4694.4,,0.01,0.001,1920.7,0.059,0.116,0.0082,32321.06,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-02",13,12.5,3075,,0.006,0.001,1243.3,0.059,0.103,0.0162,20922,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-03",24,24,5806,,0.012,0.001,2376.6,0.059,0.135,0.0068,39992.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-04",12,10.95,2492.57,,0.005,0.001,1020.66,0.059,0.089,0.0153,17174.918,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-05",24,24,5559,,0.011,0.001,2258.8,0.059,0.127,0.0067,38011.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-06",24,24,6214,,0.013,0.001,2483.5,0.059,0.143,0.0068,41792.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-07",24,24,5889,,0.012,0.001,2365,0.059,0.139,0.007,39797.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-08",2,1.7,331,,0.001,0.001,141.22,0.059,0.009,0.0075,2375.37,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-12",17,16.8,3630.6,,0.008,0.001,1506.86,0.059,0.151,0.016,25355.68,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-13",24,24,5551,,0.012,0.001,2279.1,0.059,0.138,0.0072,38352,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-14",24,24,5638,,0.012,0.001,2300.8,0.059,0.122,0.0063,38713.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-15",24,24,6020,,0.012,0.001,2455.9,0.059,0.13,0.0063,41323.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-16",24,24,5545,,0.011,0.001,2257.6,0.059,0.122,0.0064,37988.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-17",24,24,6057,,0.012,0.001,2461.3,0.059,0.127,0.0061,41421.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-18",19,17.97,4242.19,,0.009,0.001,1744.087,0.059,0.108,0.012,29344.738,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-19",24,24,5810,,0.012,0.001,2362.9,0.059,0.124,0.0062,39762.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-20",24,24,5810,,0.012,0.001,2355.7,0.059,0.125,0.0063,39640.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-21",24,24,5788,,0.012,0.001,2364.6,0.059,0.125,0.0063,39791.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-22",23,22.9,5453.9,,0.011,0.001,2213.59,0.059,0.117,0.0063,37246.56,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-23",16,15.55,3628.35,,0.007,0.001,1480.675,0.059,0.109,0.0128,24915.535,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-24",24,24,5866,,0.012,0.001,2370.4,0.059,0.121,0.0061,39883.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-25",18,17.08,4073.74,,0.008,0.001,1657.16,0.059,0.12,0.0133,27883.254,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-26",24,24,5698,,0.012,0.001,2299.8,0.059,0.126,0.0065,38700.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-27",24,24,5954,,0.012,0.001,2400,0.059,0.13,0.0065,40383.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-28",24,24,5813,,0.012,0.001,2345.7,0.059,0.121,0.0061,39473.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-29",24,24,5416,,0.011,0.001,2189.5,0.059,0.111,0.006,36844.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-30",24,24,5478,,0.011,0.001,2215.4,0.059,0.113,0.006,37280.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-10-31",24,24,5405,,0.011,0.001,2190.1,0.059,0.111,0.006,36851.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-01",24,24,5806,,0.012,0.001,2353.6,0.059,0.123,0.0062,39605,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-02",24,24,6091,,0.012,0.001,2453.7,0.059,0.141,0.0068,41289.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-03",24,24,6182,,0.013,0.001,2493.6,0.059,0.147,0.007,41956.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-04",24,24,5913,,0.012,0.001,2396.9,0.059,0.14,0.007,40336,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-05",24,24,6080,,0.012,0.001,2458.4,0.059,0.145,0.007,41366.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-06",24,24,5782,,0.012,0.001,2337.9,0.059,0.128,0.0065,39342.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-07",24,24,6298,,0.011,0.001,2256.8,0.059,0.114,0.006,37976,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-08",13,12.45,3482.35,,0.006,0.001,1175.72,0.059,0.08,0.0095,19781.36,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-09",24,24,6409,,0.011,0.001,2241.9,0.059,0.116,0.0061,37720.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-10",24,24,5685,,0.012,0.001,2309,0.059,0.133,0.0069,38856.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-11",24,24,5753,,0.012,0.001,2331.2,0.059,0.146,0.0075,39225.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-12",24,24,5654,,0.012,0.001,2291.1,0.059,0.143,0.0074,38550,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-13",24,24,5585,,0.011,0.001,2264.9,0.059,0.13,0.0068,38109.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-14",6,4.6,795.56,,0.002,0.001,351.039,0.059,0.052,0.0243,5907.598,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-17",20,19.3,4510.9,,0.009,0.001,1847.78,0.059,0.156,0.0163,31092.23,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-18",24,24,5753,,0.012,0.001,2329.3,0.059,0.122,0.0063,39195.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-19",24,24,5314,,0.011,0.001,2167,0.059,0.111,0.0061,36461.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-20",24,24,6008,,0.012,0.001,2414.7,0.059,0.13,0.0064,40631.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-21",24,24,5643,,0.012,0.001,2286.1,0.059,0.124,0.0065,38468.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-22",24,24,6855,,0.014,0.001,2781.8,0.059,0.164,0.007,46810.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-23",24,24,5623,,0.011,0.001,2266.6,0.059,0.133,0.007,38136.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-24",24,24,5921,,0.012,0.001,2387.6,0.059,0.141,0.007,40173.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-25",24,24,5858,,0.012,0.001,2364.8,0.059,0.125,0.0063,39795.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-26",4,3.77,886.99,,0.002,0.001,363.303,0.059,0.021,0.0073,6113.201,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-27",8,7.63,1798.58,,0.004,0.001,740.276,0.059,0.092,0.0245,12455.704,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-28",13,12.4,2839,,0.006,0.001,1166.31,0.059,0.099,0.0151,19627.238,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-29",24,24,5965,,0.012,0.001,2412.1,0.059,0.152,0.0075,40594.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-11-30",24,24,6563,,0.013,0.001,2655.2,0.059,0.156,0.007,44677.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-01",24,24,6761,,0.014,0.001,2735.8,0.059,0.161,0.007,46035.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-02",24,24,6101,,0.012,0.001,2450.1,0.059,0.144,0.007,41229,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-03",24,24,6131,,0.012,0.001,2461.6,0.059,0.144,0.007,41423.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-04",24,24,6154,,0.013,0.001,2543.9,0.059,0.149,0.007,42806.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-05",24,24,5953,,0.012,0.001,2457.6,0.059,0.145,0.007,41357.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-06",24,24,5901,,0.012,0.001,2438.9,0.059,0.143,0.007,41036.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-07",24,24,5946,,0.013,0.001,2477.3,0.059,0.145,0.007,41682.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-08",22,21.78,5215.72,,0.011,0.001,2199.202,0.059,0.13,0.007,37004.77,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-16",9,8.05,1876.05,,0.004,0.001,774.515,0.059,0.097,0.0216,13034.185,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-17",24,24,6024,,0.012,0.001,2432.3,0.059,0.142,0.007,40929.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-18",24,24,6170,,0.013,0.001,2494.1,0.059,0.146,0.007,41967.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-19",24,24,5650,,0.012,0.001,2291.5,0.059,0.134,0.007,38557.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-20",15,13.83,3129.36,,0.007,0.001,1288.682,0.059,0.098,0.0145,21683.809,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-21",24,24,5794,,0.012,0.001,2337.7,0.059,0.125,0.0063,39336,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-22",24,24,5725,,0.012,0.001,2319.6,0.059,0.119,0.0061,39029.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-23",24,24,5949,,0.012,0.001,2410.6,0.059,0.136,0.0067,40568.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-24",24,24,6117,,0.012,0.001,2463.8,0.059,0.145,0.007,41459.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-25",24,24,5805,,0.012,0.001,2355.2,0.059,0.138,0.007,39631.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-26",12,11.28,2508.72,,0.005,0.001,1048.186,0.059,0.102,0.0183,17641.244,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-27",24,24,5912,,0.012,0.001,2389.1,0.059,0.153,0.0076,40200.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-28",24,24,6303,,0.013,0.001,2547.3,0.059,0.167,0.0078,42858.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-29",24,24,5667,,0.012,0.001,2289.2,0.059,0.146,0.0076,38518.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-30",24,24,5707,,0.012,0.001,2309.5,0.059,0.148,0.0076,38862.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"2",,"2020-12-31",24,24,5666,,0.012,0.001,2299.7,0.059,0.149,0.0077,38701.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-01",2,2,437,,0.001,0.001,181.1,0.059,0.013,0.0085,3047.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-02",10,9.92,2392.64,,0.005,0.001,1001.44,0.059,0.094,0.0154,16851.516,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-03",20,19.02,4754.82,,0.01,0.001,1989.406,0.059,0.148,0.0109,33477.503,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-04",9,7.8,1762.98,,0.004,0.001,752.688,0.059,0.079,0.0213,12663.456,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-05",15,14.5,3541.1,,0.008,0.001,1488.5,0.059,0.12,0.0125,25047,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-06",24,24,5958,,0.012,0.001,2452.9,0.059,0.162,0.0079,41272.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-07",24,24,6166,,0.013,0.001,2540.2,0.059,0.16,0.0075,42741.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-08",11,10.22,2411.92,,0.005,0.001,1021.242,0.059,0.097,0.0164,17184.472,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-09",24,24,6175,,0.013,0.001,2557.8,0.059,0.169,0.0078,43042.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-10",24,24,6065,,0.013,0.001,2502.9,0.059,0.162,0.0077,42114.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-11",10,8.82,1967.06,,0.004,0.001,835.044,0.059,0.087,0.0203,14053.126,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-12",15,14.03,2800.28,,0.006,0.001,1258.488,0.059,0.133,0.0187,21175.518,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-13",20,18.97,4714.97,,0.01,0.001,1978.234,0.059,0.149,0.0114,33286.758,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-14",20,19,4682.05,,0.01,0.001,1961.918,0.059,0.142,0.0108,33009.52,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-15",24,24,6156,,0.013,0.001,2533.9,0.059,0.159,0.0075,42634.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-16",19,18,4420.59,,0.009,0.001,1849.223,0.059,0.147,0.0124,31118.635,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-17",24,24,6101,,0.013,0.001,2518.3,0.059,0.158,0.0075,42377.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-18",17,15.93,3835.94,,0.008,0.001,1601.159,0.059,0.11,0.0099,26941.179,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-19",13,12.01,2922.13,,0.007,0.001,1301.977,0.059,0.104,0.0134,21907.033,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-20",24,24,6412,,0.014,0.001,2802.9,0.059,0.17,0.0072,47168.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-21",24,24,6049,,0.013,0.001,2589.3,0.059,0.162,0.0075,43566,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-22",24,24,5475,,0.011,0.001,2260.8,0.059,0.15,0.0079,38040.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-23",20,17.42,4092.39,,0.009,0.001,1741.889,0.059,0.148,0.0185,29311.464,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-24",3,2.1,502,,0.001,0.001,212.03,0.059,0.015,0.0107,3566.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-25",13,12.87,2692.89,,0.006,0.001,1234.134,0.059,0.121,0.0158,20766.831,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-26",14,13.12,2738.52,,0.006,0.001,1216.797,0.059,0.111,0.015,20475.484,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-27",19,17.93,3937.26,,0.008,0.001,1648.063,0.059,0.118,0.0098,27731.016,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-28",18,16.36,3962.11,,0.008,0.001,1650.56,0.059,0.113,0.01,27777.318,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-29",11,10.25,2416.62,,0.005,0.001,1030.224,0.059,0.09,0.0152,17334.778,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-30",22,20.97,5098.66,,0.011,0.001,2134.909,0.059,0.15,0.0105,35925.464,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-01-31",21,19.52,4764.32,,0.01,0.001,2026.921,0.059,0.145,0.0133,34105.022,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-01",9,8.14,1769.32,,0.004,0.001,751.899,0.059,0.081,0.0177,12651.804,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-02",11,9.06,1854.12,,0.004,0.001,835.743,0.0591,0.105,0.0292,14062.558,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-03",10,9.03,2136,,0.005,0.001,905.514,0.059,0.088,0.0148,15238.484,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-04",21,19.97,5024.11,,0.011,0.001,2101.098,0.059,0.149,0.0103,35355.922,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-05",18,17.42,4340.2,,0.009,0.001,1811.514,0.059,0.123,0.0105,30482.598,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-06",17,15.92,3985.36,,0.008,0.001,1664.292,0.059,0.117,0.0111,28006.805,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-07",17,15.07,3304.88,,0.007,0.001,1452.23,0.059,0.139,0.0165,24436.571,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-08",2,1.05,242.8,,0.001,0.001,102.445,0.059,0.01,0.0555,1723.88,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-09",12,11.07,2212,,0.005,0.001,1032.811,0.059,0.142,0.0253,17380.112,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-10",18,16.75,4156.62,,0.009,0.001,1728.603,0.059,0.124,0.0094,29085.621,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-11",18,17.52,4363.65,,0.009,0.001,1819.731,0.059,0.126,0.0101,30619.509,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-12",24,24,5935,,0.012,0.001,2466.1,0.059,0.162,0.0078,41497.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-13",18,17.22,4373.34,,0.009,0.001,1826.656,0.059,0.14,0.0132,30739.373,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-14",17,15.92,4023.83,,0.008,0.001,1679.726,0.059,0.128,0.0129,28264.416,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-15",13,11.3,2807.55,,0.006,0.001,1176.74,0.0591,0.093,0.013,19799.505,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-16",13,12.33,2612.15,,0.006,0.001,1168.61,0.059,0.111,0.015,19667.955,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-17",14,12.54,2723.85,,0.006,0.001,1194.866,0.059,0.121,0.0204,20105.985,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-18",22,20.92,5077.08,,0.011,0.001,2137.836,0.059,0.184,0.0141,35969.208,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-19",22,21.17,5098.59,,0.011,0.001,2159.823,0.059,0.188,0.013,36346.153,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-20",18,16.47,4151.08,,0.009,0.001,1734.079,0.059,0.14,0.0176,29182.223,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-21",19,17.82,4478.69,,0.009,0.001,1864.167,0.059,0.138,0.0115,31369.383,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-22",2,1.65,378.95,,0.001,0.001,164.045,0.059,0.012,0.0085,2759.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-23",11,10.73,2164.93,,0.005,0.001,1002.907,0.059,0.131,0.0234,16872.814,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-24",15,13.15,2727.9,,0.006,0.001,1230.15,0.059,0.105,0.015,20699.12,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-25",24,24,6089,,0.013,0.001,2510.2,0.059,0.153,0.0073,42245.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-26",19,18.37,4592.3,,0.01,0.001,1915.496,0.059,0.144,0.0116,32231.498,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-27",22,20.62,4968.2,,0.011,0.001,2094.262,0.059,0.164,0.0126,35239.486,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-28",19,18.28,4504.1,,0.009,0.001,1876.23,0.059,0.134,0.0124,31569.122,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-02-29",1,0.97,180.42,,0,0.001,76.339,0.059,0.006,0.009,1283.892,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-01",12,11.57,2477.23,,0.006,0.001,1117.208,0.059,0.129,0.0225,18800.905,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-02",16,14.82,3713.3,,0.008,0.001,1553.18,0.059,0.12,0.0133,26135.869,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-03",15,12.55,2900.14,,0.006,0.001,1234.053,0.059,0.107,0.0162,20764.159,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-04",16,14.89,3711.4,,0.008,0.001,1550.895,0.059,0.117,0.0139,26097.287,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-05",20,18.55,4601.98,,0.01,0.001,1915.433,0.059,0.133,0.0113,32229.953,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-06",24,24,5800,,0.012,0.001,2405,0.059,0.157,0.0078,40465.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-07",14,12.27,2767.7,,0.006,0.001,1217.761,0.0591,0.127,0.0226,20487.956,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-08",12,10.41,2537.74,,0.005,0.001,1069.416,0.059,0.104,0.023,17995.906,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-09",24,24,6036,,0.013,0.001,2502.8,0.059,0.156,0.0074,42114.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-10",24,24,6330,,0.013,0.001,2613.2,0.059,0.156,0.0071,43974.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-11",24,24,5921,,0.012,0.001,2450.4,0.059,0.144,0.007,41234.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-12",24,24,6388,,0.013,0.001,2642.1,0.059,0.156,0.007,44460.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-13",24,24,5920,,0.012,0.001,2449.4,0.059,0.156,0.0076,41216.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-14",18,17.17,4359.92,,0.009,0.001,1825.7,0.059,0.145,0.0141,30719.737,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-15",22,20.84,5132.93,,0.011,0.001,2174.123,0.059,0.177,0.0134,36582.637,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-16",24,24,6567,,0.014,0.001,2719.2,0.059,0.175,0.0076,45753.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-17",24,24,6023,,0.013,0.001,2489.9,0.059,0.164,0.0078,41898.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-18",24,24,6237,,0.013,0.001,2573.5,0.059,0.166,0.0077,43302.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-19",24,24,5865,,0.012,0.001,2434.5,0.059,0.159,0.0078,40970.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-20",21,20.02,4931.79,,0.01,0.001,2065.931,0.059,0.14,0.0095,34762.481,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-21",8,6.39,1476.02,,0.003,0.001,640.291,0.059,0.064,0.0186,10775.227,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-22",15,13.23,3317.49,,0.007,0.001,1385.882,0.059,0.113,0.0182,23323.318,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-23",17,15.24,3190.62,,0.007,0.001,1395.729,0.059,0.138,0.0173,23483.974,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-24",18,17.15,4164.15,,0.009,0.001,1751.825,0.059,0.136,0.0114,29480.93,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-25",10,9.2,2209.8,,0.005,0.001,934.34,0.059,0.091,0.0183,15721.62,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-26",16,14.25,3045.45,,0.007,0.001,1339.616,0.059,0.147,0.0221,22540.002,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-27",2,1.02,235.18,,0.001,0.001,99.404,0.059,0.009,0.058,1672.052,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-28",9,8.28,1988.36,,0.004,0.001,841.016,0.059,0.086,0.0248,14152.312,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-29",3,2.12,512,,0.001,0.001,213.756,0.059,0.013,0.0093,3596.016,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-30",10,8.65,1611.17,,0.004,0.001,781.067,0.059,0.106,0.0284,13143.453,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-03-31",11,10.43,1842.03,,0.004,0.001,870.281,0.059,0.098,0.0215,14645.654,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-01",24,24,5870,,0.012,0.001,2435,0.059,0.159,0.0078,40978.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-02",11,9.8,1957.73,,0.005,0.001,902.49,0.059,0.091,0.0154,15185.161,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-03",24,24,5919,,0.012,0.001,2449.5,0.059,0.16,0.0078,41218.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-04",24,24,6232,,0.013,0.001,2590.2,0.059,0.163,0.0075,43583,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-05",24,24,6170,,0.013,0.001,2552.6,0.059,0.169,0.0079,42951,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-06",24,24,6181,,0.013,0.001,2549.6,0.059,0.164,0.0077,42901.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-07",24,24,6059,,0.013,0.001,2498.3,0.059,0.16,0.0076,42039.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-08",24,24,6504,,0.014,0.001,2687.1,0.059,0.177,0.0078,45215.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-09",24,24,6245,,0.013,0.001,2573.1,0.059,0.157,0.0073,43299.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-10",24,24,5971,,0.012,0.001,2463.8,0.059,0.163,0.0079,41457.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-11",10,8.89,2003.37,,0.004,0.001,855.665,0.059,0.09,0.0195,14399.425,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-12",16,14.72,3219.88,,0.007,0.001,1419.77,0.0591,0.144,0.0197,23892.236,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-13",19,18.55,4272.38,,0.009,0.001,1776.519,0.059,0.128,0.0103,29895.114,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-14",19,18.22,4342.49,,0.009,0.001,1801.855,0.059,0.132,0.0101,30319.322,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-15",11,10.48,2407.16,,0.005,0.001,1017.821,0.059,0.088,0.0153,17125.205,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-16",13,11.7,2752.46,,0.006,0.001,1173.124,0.059,0.1,0.0165,19740.038,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-17",10,8.57,1543.33,,0.004,0.001,730.779,0.059,0.096,0.0214,12295.606,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-18",6,5.98,1408.86,,0.003,0.001,596.908,0.059,0.064,0.0167,10045.036,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-19",11,9.59,1930.29,,0.004,0.001,884.742,0.059,0.105,0.0207,14890.147,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-20",9,8.17,1584.42,,0.004,0.001,744.082,0.059,0.092,0.0194,12519.966,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-21",9,8.45,1639.32,,0.004,0.001,759.582,0.059,0.102,0.0238,12783.032,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-22",10,9.7,2000.4,,0.005,0.001,900.03,0.059,0.121,0.0237,15146.08,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-23",7,5.45,796.42,,0.002,0.001,415.004,0.059,0.102,0.0329,6982.747,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-26",12,11.97,2519.65,,0.006,0.001,1127.905,0.059,0.151,0.0222,18980.704,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-27",14,13.3,2772.32,,0.006,0.001,1197.458,0.059,0.097,0.0122,20154.06,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-28",9,8.05,1727,,0.004,0.001,736.815,0.059,0.076,0.0229,12399.485,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-29",1,0.73,133.59,,0,0.001,61.758,0.059,0.004,0.007,1039.593,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-04-30",11,10.16,1804.77,,0.004,0.001,826.313,0.059,0.094,0.0182,13905.293,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-08",4,3.53,693.97,,0.002,0.001,308.154,0.059,0.084,0.0533,5184.743,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-09",13,11.62,2485.41,,0.006,0.001,1113.747,0.059,0.102,0.0157,18740.189,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-10",18,17.42,3884.76,,0.008,0.001,1680.054,0.059,0.118,0.0121,28266.22,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-11",10,7.63,1649.21,,0.004,0.001,714.907,0.059,0.078,0.0269,12029.008,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-12",16,14.86,3212.63,,0.007,0.001,1398.38,0.059,0.123,0.0136,23529.232,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-13",10,8.9,1725.72,,0.004,0.001,801.738,0.059,0.097,0.0276,13491.018,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-14",10,9.8,2006.8,,0.005,0.001,896.38,0.059,0.095,0.0181,15084.64,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-15",16,14.35,2992.9,,0.007,0.001,1310.75,0.059,0.12,0.0223,22056.285,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-16",10,7.76,1419.4,,0.003,0.001,659.416,0.059,0.073,0.0237,11093.304,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-17",2,1.67,251.24,,0.001,0.001,116.758,0.059,0.034,0.0515,1964.49,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-18",24,24,5557,,0.012,0.001,2283.4,0.059,0.147,0.0076,38418.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-19",19,17.75,3874.05,,0.008,0.001,1648.16,0.0591,0.135,0.0124,27733.905,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-20",10,8.55,1682.06,,0.004,0.001,767.244,0.059,0.088,0.0242,12909.518,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-21",13,12.15,2574.72,,0.006,0.001,1093.353,0.059,0.094,0.0133,18395.918,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-22",14,12.4,3002.68,,0.006,0.001,1249.52,0.059,0.093,0.0196,21026.542,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-23",24,24,6047,,0.013,0.001,2477.2,0.059,0.16,0.0077,41682.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-24",14,13.04,3126.2,,0.007,0.001,1324.292,0.059,0.091,0.0094,22282.562,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-25",16,15.56,3414.28,,0.008,0.001,1490.838,0.059,0.106,0.0103,25086.13,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-26",15,13.95,3370.29,,0.007,0.001,1416.791,0.059,0.094,0.0105,23840.293,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-27",12,11.1,2621.15,,0.006,0.001,1105.41,0.059,0.087,0.0128,18603.21,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-28",1,0.5,65,,0,0.001,35.7,0.059,0.005,0.016,600.65,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-29",11,10.23,2073.92,,0.005,0.001,938.909,0.0591,0.123,0.0286,15797.642,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-06-30",16,14.75,3151.19,,0.007,0.001,1385.273,0.059,0.132,0.0167,23310.895,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-01",15,13.43,2883.43,,0.006,0.001,1251.282,0.059,0.12,0.0177,21054.498,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-02",3,2.82,669.08,,0.001,0.001,280.348,0.059,0.018,0.0077,4715.988,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-05",10,9.42,1486.74,,0.004,0.001,740.876,0.059,0.092,0.0225,12464.99,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-06",15,14.23,2887.15,,0.006,0.001,1255.579,0.059,0.114,0.0171,21126.831,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-07",12,11.27,2421.15,,0.005,0.001,1026.137,0.059,0.086,0.0124,17269.15,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-08",11,10.23,2176.45,,0.005,0.001,925.743,0.059,0.069,0.0125,15576.45,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-09",14,13.2,2965.16,,0.006,0.001,1251.386,0.059,0.091,0.0107,21059.663,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-10",14,12.73,2901.54,,0.006,0.001,1220.308,0.059,0.1,0.0159,20538.784,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-11",13,11.04,2629.06,,0.006,0.0009,1101.286,0.0591,0.082,0.0117,18533.404,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-12",12,11.51,2514.09,,0.005,0.001,1060.452,0.059,0.081,0.013,17841.219,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-13",12,11.01,2512.8,,0.005,0.001,1052.537,0.059,0.072,0.01,17708.899,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-14",14,13.55,3053.39,,0.006,0.001,1277.111,0.059,0.085,0.0099,21489.774,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-15",12,10.62,2362.3,,0.005,0.001,987.656,0.0591,0.083,0.0152,16618.982,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-16",13,11.9,2730.2,,0.006,0.001,1155.95,0.059,0.088,0.0118,19450.13,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-17",16,15.25,3375.1,,0.007,0.001,1425.48,0.059,0.1,0.0103,23987.235,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-18",12,11.07,2442.96,,0.005,0.001,1037.758,0.059,0.077,0.0116,17464.366,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-19",11,10.2,2320.28,,0.005,0.001,978.079,0.059,0.074,0.011,16461.025,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-20",13,12.07,2674.08,,0.006,0.001,1126.592,0.059,0.088,0.0133,18956.403,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-21",14,12.6,2808.17,,0.006,0.001,1190.061,0.059,0.095,0.0154,20024.57,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-22",7,6.77,1403.82,,0.003,0.001,588.329,0.059,0.036,0.0073,9899.837,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-23",8,7.88,1623.96,,0.003,0.001,691.888,0.059,0.055,0.0124,11643.052,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-24",12,11.5,2407.96,,0.005,0.001,1016.706,0.059,0.076,0.011,17107.713,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-25",9,8.05,1892.05,,0.004,0.001,796.42,0.059,0.069,0.015,13401.325,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-26",10,8.8,1986.06,,0.004,0.001,839.073,0.059,0.075,0.0147,14120.699,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-27",14,13.22,3091.62,,0.007,0.001,1294.497,0.059,0.093,0.0108,21781.68,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-28",14,12.99,3027,,0.006,0.001,1275.585,0.059,0.093,0.0134,21466.688,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-29",24,24,5739,,0.012,0.001,2367.9,0.059,0.139,0.007,39844.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-30",24,24,5826,,0.012,0.001,2405.5,0.059,0.133,0.0065,40475.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-07-31",24,24,5697,,0.012,0.001,2349.8,0.059,0.138,0.007,39536.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-01",24,24,5297,,0.011,0.001,2199.4,0.059,0.13,0.007,37010.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-02",11,9.98,2244.45,,0.005,0.001,945.425,0.059,0.068,0.0108,15907.768,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-03",12,11.11,2491.79,,0.005,0.001,1047.279,0.059,0.076,0.01,17618.565,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-04",11,10.13,2192.63,,0.005,0.001,936.88,0.059,0.071,0.0105,15765.316,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-05",14,13.17,2736.2,,0.006,0.001,1151.982,0.059,0.094,0.0112,19383.014,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-06",1,0.28,24.64,,0,0.001,17.024,0.059,0.003,0.021,286.328,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-08",8,7.9,1779.7,,0.004,0.001,749.39,0.059,0.071,0.0163,12609.17,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-09",15,14.33,3151.76,,0.007,0.001,1327.941,0.059,0.09,0.0091,22343.77,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-10",14,13.05,2923.95,,0.006,0.001,1230.307,0.059,0.077,0.0085,20703.28,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-11",14,12.8,2883.44,,0.006,0.001,1215.962,0.0591,0.089,0.0131,20461.646,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-12",24,24,5627,,0.012,0.001,2342.9,0.059,0.138,0.007,39426.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-13",24,24,5908,,0.012,0.001,2454.8,0.059,0.145,0.007,41308.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-14",24,24,6249,,0.013,0.001,2617.2,0.059,0.154,0.007,44037.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-15",24,24,6207,,0.013,0.001,2597.4,0.059,0.153,0.007,43706.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-16",24,24,6058,,0.013,0.001,2536.5,0.059,0.149,0.007,42679.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-17",24,24,6288,,0.013,0.001,2636,0.059,0.155,0.007,44354.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-18",24,24,6306,,0.013,0.001,2656.4,0.059,0.154,0.0069,44698.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-19",24,24,6300,,0.013,0.001,2629.7,0.059,0.153,0.0069,44251.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-20",24,24,6208,,0.013,0.001,2580.3,0.059,0.137,0.0063,43413,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-21",24,24,6131,,0.013,0.001,2556.1,0.059,0.147,0.0068,43007.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-22",24,24,5858,,0.012,0.001,2427.4,0.059,0.143,0.007,40847.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-23",24,24,5965,,0.013,0.001,2484.8,0.059,0.146,0.007,41811.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-24",24,24,6231,,0.013,0.001,2619.4,0.059,0.154,0.007,44071.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-25",24,24,6152,,0.013,0.001,2572.2,0.059,0.152,0.007,43281.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-26",24,24,5482,,0.011,0.001,2259.2,0.059,0.134,0.007,38015.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-27",7,6.63,1360.38,,0.003,0.001,571.443,0.059,0.034,0.007,9615.261,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-29",1,0.18,0.72,,0,0.001,4.482,0.059,0.003,0.089,75.474,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-30",10,9.73,2148.18,,0.005,0.001,912.637,0.059,0.088,0.0173,15353.851,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-08-31",18,17.69,4037.62,,0.009,0.001,1702.492,0.059,0.114,0.0087,28647.188,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-01",11,10.83,2431.72,,0.005,0.001,1032.792,0.059,0.081,0.0118,17375.628,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-02",24,24,5119,,0.011,0.001,2138.9,0.059,0.126,0.007,35986.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-03",24,24,5893,,0.012,0.001,2448.6,0.059,0.144,0.007,41200,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-04",24,24,5930,,0.012,0.001,2452.8,0.059,0.145,0.007,41269.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-05",24,24,5549,,0.012,0.001,2316.7,0.059,0.136,0.007,38980.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-06",24,24,5665,,0.012,0.001,2369.8,0.059,0.14,0.007,39877.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-07",24,24,6252,,0.013,0.001,2622,0.059,0.154,0.007,44121.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-08",24,24,6413,,0.014,0.001,2677,0.059,0.158,0.007,45044.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-09",24,24,5376,,0.011,0.001,2230.5,0.059,0.131,0.007,37531.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-10",24,24,5307,,0.011,0.001,2197.5,0.059,0.129,0.007,36976,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-11",12,11.13,2414.71,,0.005,0.001,1023.141,0.059,0.069,0.0091,17216.036,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-12",1,0.52,72.28,,0,0.001,38.74,0.059,0.003,0.009,651.612,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-13",11,10.07,2208.07,,0.005,0.001,937.513,0.059,0.081,0.015,15775.818,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-14",24,24,5512,,0.012,0.001,2289.3,0.059,0.134,0.007,38520.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-15",24,24,5440,,0.011,0.001,2267.9,0.059,0.133,0.007,38163.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-16",24,24,5694,,0.012,0.001,2358.7,0.059,0.137,0.0069,39690.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-17",24,24,5794,,0.012,0.001,2398.3,0.059,0.139,0.0069,40361.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-18",24,24,5686,,0.012,0.001,2356.5,0.059,0.14,0.0071,39652.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-19",10,8.83,1960.67,,0.004,0.001,824.999,0.059,0.067,0.0208,13882.275,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-20",15,14.45,3187.66,,0.007,0.001,1340.31,0.059,0.088,0.0088,22555.67,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-21",17,16.03,3397.06,,0.007,0.001,1482.098,0.059,0.11,0.0119,24936.704,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-22",12,11.12,2549.03,,0.005,0.001,1069.813,0.059,0.075,0.0113,18002.838,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-23",24,24,5619,,0.012,0.001,2327.7,0.059,0.125,0.0064,39170.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-24",18,17.1,3668.09,,0.008,0.001,1543.89,0.059,0.125,0.0123,25977.493,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-25",12,11.22,2090.46,,0.005,0.001,913.271,0.059,0.096,0.0215,15369.451,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-26",14,13.6,2499.2,,0.005,0.001,1074.58,0.059,0.099,0.0143,18083.46,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-27",17,15.6,3471.14,,0.007,0.001,1439.744,0.059,0.137,0.0169,24227.418,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-28",24,24,5661,,0.011,0.001,2263,0.059,0.14,0.0073,38081.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-29",24,24,5684,,0.011,0.001,2276.9,0.059,0.15,0.0078,38313.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-09-30",24,24,5974,,0.012,0.001,2390.1,0.059,0.157,0.0078,40216.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-01",24,24,5713,,0.012,0.001,2289.5,0.059,0.135,0.007,38518.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-02",24,24,5886,,0.012,0.001,2351.7,0.059,0.147,0.0074,39572.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-03",14,13.12,2963.16,,0.006,0.001,1195.342,0.0591,0.091,0.0124,20115.093,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-04",16,14.98,3172.42,,0.007,0.001,1346.058,0.059,0.1,0.0125,22652.624,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-05",24,24,5421,,0.011,0.001,2184.6,0.059,0.122,0.0066,36760.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-06",24,24,6084,,0.012,0.001,2433.8,0.059,0.141,0.0069,40949.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-07",24,24,5826,,0.012,0.001,2337.6,0.059,0.139,0.0071,39334.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-08",3,2.13,458.05,,0.001,0.001,182.261,0.059,0.01,0.0087,3067.258,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-11",22,21.42,4625.28,,0.01,0.001,2072.214,0.059,0.201,0.0175,34868.43,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-12",24,24,5594,,0.012,0.001,2386.6,0.059,0.153,0.0076,40161.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-13",12,10.84,2547.63,,0.006,0.001,1089.921,0.059,0.085,0.0146,18338.105,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-14",18,17.32,4009.48,,0.009,0.001,1694.726,0.059,0.102,0.0083,28517.598,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-15",15,13.66,3384.46,,0.007,0.001,1443.14,0.059,0.101,0.0134,24284.012,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-16",24,24,5564,,0.012,0.001,2320.8,0.059,0.131,0.0067,39054,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-17",24,24,6050,,0.013,0.001,2522.8,0.059,0.141,0.0066,42452.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-18",14,12.45,2981.94,,0.006,0.001,1262.225,0.059,0.095,0.0201,21236.676,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-19",15,13.75,3272.41,,0.007,0.001,1381.421,0.059,0.09,0.0124,23245.683,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-20",21,19.24,4662.6,,0.01,0.001,1954.138,0.059,0.108,0.0068,32884.184,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-21",20,19.13,4755.31,,0.01,0.001,2006.42,0.059,0.112,0.0072,33761.657,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-22",24,24,5770,,0.012,0.001,2399.7,0.059,0.127,0.0063,40380.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-23",24,24,5991,,0.013,0.001,2495.9,0.059,0.132,0.0063,41999.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-24",18,17.54,4331.98,,0.009,0.001,1811.607,0.059,0.112,0.0094,30485.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-25",12,11.48,2711.64,,0.006,0.001,1149.131,0.059,0.085,0.0126,19336.197,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-26",19,18.69,4553.68,,0.01,0.001,1898.591,0.059,0.124,0.0088,31946.535,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-27",24,24,5996,,0.012,0.001,2473.2,0.059,0.126,0.006,41613.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-28",24,24,5905,,0.012,0.001,2443.1,0.059,0.131,0.0064,41113,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-29",24,24,5515,,0.012,0.001,2280.1,0.059,0.124,0.0065,38367.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-30",17,15.86,3650.69,,0.008,0.001,1529.354,0.059,0.089,0.0113,25733.518,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-10-31",18,17.47,3935.24,,0.008,0.001,1646.244,0.059,0.098,0.0088,27702.795,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-01",13,10.8,2295.44,,0.005,0.001,980.776,0.0591,0.091,0.023,16504.224,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-02",24,24,6117,,0.013,0.001,2527.7,0.059,0.144,0.0068,42533,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-03",24,24,6198,,0.013,0.001,2565.8,0.059,0.151,0.007,43175.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-04",24,24,5913,,0.012,0.001,2451.6,0.059,0.144,0.007,41250.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-05",24,24,6136,,0.013,0.001,2546.6,0.059,0.15,0.007,42850.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-06",21,19.58,4728.79,,0.01,0.001,1972.949,0.059,0.115,0.0091,33201.621,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-07",20,18.92,4854.78,,0.009,0.001,1870.279,0.059,0.106,0.008,31470.23,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-08",13,12.39,3529.91,,0.006,0.001,1228.328,0.059,0.084,0.0098,20670.7,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-09",19,18.33,4749.05,,0.009,0.001,1806.442,0.059,0.126,0.0108,30399.995,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-10",19,17.77,4333.39,,0.009,0.001,1819.426,0.059,0.137,0.0125,30613.094,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-11",20,19.46,4774.04,,0.01,0.001,1993.484,0.059,0.136,0.0105,33546.352,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-12",20,18.7,4479.58,,0.009,0.001,1872.978,0.059,0.126,0.0103,31517.74,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-13",19,18.46,4268.9,,0.009,0.001,1791.438,0.059,0.118,0.0085,30145.451,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-14",12,10.35,2364.65,,0.005,0.001,1010.355,0.0591,0.093,0.0149,16998.404,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-15",13,12.46,2891.83,,0.006,0.001,1251.944,0.059,0.1,0.0117,21067.128,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-16",24,24,5930,,0.013,0.001,2486.2,0.059,0.146,0.007,41834.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-17",24,24,6015,,0.013,0.001,2512.2,0.059,0.148,0.007,42268.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-18",24,24,5820,,0.012,0.001,2417.5,0.059,0.142,0.007,40679.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-19",12,11.2,2597.51,,0.006,0.001,1099.157,0.059,0.071,0.0095,18495.731,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-20",24,24,6106,,0.013,0.001,2530.2,0.059,0.131,0.0062,42576.2,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-21",13,12.2,2846.2,,0.006,0.001,1198.62,0.059,0.096,0.0125,20171.01,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-22",24,24,6691,,0.014,0.001,2788.4,0.059,0.164,0.007,46920,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-23",24,24,5699,,0.012,0.001,2354.7,0.059,0.139,0.007,39620.9,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-24",24,24,6001,,0.013,0.001,2484.1,0.059,0.146,0.007,41800.3,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-25",19,17.24,4195.04,,0.009,0.001,1752.16,0.059,0.116,0.0133,29483.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-26",4,3.25,772.25,,0.002,0.001,325.5,0.059,0.023,0.0153,5477.1,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-27",15,14.12,2981,,0.007,0.001,1346.496,0.059,0.137,0.0191,22657.484,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-28",11,10.14,2367.55,,0.005,0.001,997.743,0.059,0.078,0.0114,16788.816,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-29",12,11.62,2827.98,,0.006,0.001,1187.556,0.059,0.095,0.0122,19982.672,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-11-30",21,20.6,5480.2,,0.012,0.001,2292.54,0.059,0.159,0.011,38577.86,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-01",24,24,6600,,0.014,0.001,2742.7,0.059,0.162,0.007,46150.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-02",15,14.17,3564.03,,0.007,0.001,1476.016,0.059,0.087,0.0069,24836.948,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-15",8,7.75,1568.25,,0.003,0.001,690.325,0.059,0.101,0.0266,11617.325,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-16",24,24,6194,,0.013,0.001,2595.8,0.059,0.153,0.007,43677.6,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-17",24,24,6104,,0.013,0.001,2526.4,0.059,0.148,0.007,42512.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-18",12,10.91,2509.49,,0.005,0.001,1066.83,0.059,0.086,0.0143,17951.454,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-19",20,18.33,4436.58,,0.009,0.001,1854.216,0.059,0.128,0.0111,31202.823,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-20",18,16.87,3594.64,,0.008,0.001,1583.949,0.059,0.126,0.012,26651.758,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-21",22,20.95,5099.22,,0.011,0.001,2116.74,0.059,0.14,0.0113,35622.708,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-22",21,18.69,4197.6,,0.009,0.001,1769.728,0.059,0.126,0.0141,29783.418,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-23",21,20,5094.25,,0.011,0.001,2128.5,0.059,0.133,0.0086,35814.875,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-24",24,24,6221,,0.013,0.001,2568.8,0.059,0.135,0.0063,43225,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-25",19,18.26,4503.97,,0.01,0.001,1885.398,0.059,0.113,0.0082,31724.823,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-26",10,8.9,1979.17,,0.004,0.001,843.615,0.059,0.074,0.0185,14195.459,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-27",24,24,5996,,0.013,0.001,2484.7,0.059,0.16,0.0077,41805.8,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-28",24,24,6328,,0.013,0.001,2622.6,0.059,0.164,0.0075,44135.5,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-29",24,24,5730,,0.012,0.001,2369.9,0.059,0.156,0.0078,39877.4,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-30",21,20.58,4945.48,,0.01,0.001,2060.078,0.059,0.149,0.0102,34667.368,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Delta Energy Center, LLC",55333,"3",,"2020-12-31",19,17.81,4307.85,,0.009,0.001,1796.701,0.059,0.128,0.0152,30231.929,"Pipeline Natural Gas",,"Combined cycle",,"Ammonia Injection",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-07",7,6.1,707.92,,0.002,0.001,356.208,0.059,0.098,0.0521,5991.614,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-10",17,14.41,2308.76,,0.005,0.001,1085.43,0.059,0.163,0.0366,18261.204,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-13",16,14.75,2088.26,,0.005,0.0009,1006.802,0.0591,0.133,0.0259,16943.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-15",15,12.82,1954.19,,0.005,0.001,939.796,0.0591,0.115,0.0259,15811.682,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-20",15,13.72,2108.67,,0.005,0.001,990.843,0.059,0.151,0.0371,16670.767,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-23",16,14.12,1992.54,,0.005,0.001,916.314,0.059,0.082,0.0248,15417.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-24",19,17.53,3214.19,,0.007,0.001,1399.131,0.059,0.066,0.0076,23540.693,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-27",12,10.76,1418.25,,0.004,0.001,706.911,0.059,0.118,0.0389,11897.923,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-28",7,6.18,959.2,,0.002,0.001,434.508,0.059,0.038,0.0133,7309.502,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-10",8,7.03,1240.57,,0.003,0.001,547.097,0.059,0.061,0.0335,9206.165,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-11",7,6.03,1307.31,,0.003,0.001,548.666,0.0591,0.045,0.0163,9233.049,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-13",14,12.64,2642.62,,0.006,0.001,1132.369,0.059,0.103,0.0191,19055.482,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-14",16,14.35,2877.8,,0.006,0.001,1222.03,0.0591,0.07,0.0132,20561.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-15",18,15.18,2759.07,,0.006,0.0009,1189.591,0.0591,0.065,0.0086,20017.185,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-17",10,8.29,1753.23,,0.004,0.001,738.113,0.059,0.06,0.0181,12421.766,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-18",15,12.23,2314.71,,0.005,0.001,1012.079,0.0591,0.06,0.0084,17030.057,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-19",10,9.02,1923,,0.004,0.001,805.56,0.0591,0.048,0.0083,13553.382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-20",17,15.1,2665.12,,0.006,0.001,1155.595,0.0591,0.071,0.0144,19443.936,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-21",3,2.08,288.08,,0.001,0.001,131.188,0.0593,0.006,0.0157,2207.812,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-25",20,17.66,3617.5,,0.008,0.001,1533.04,0.0591,0.114,0.0213,25799.532,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-26",17,15.65,2909.19,,0.006,0.001,1250.031,0.0591,0.064,0.0065,21032.545,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-27",11,10.07,2080.07,,0.004,0.001,874.239,0.059,0.054,0.0093,14710.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-28",8,6.11,1008.25,,0.002,0.001,442.148,0.0591,0.039,0.0145,7437.98,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-02",6,5.67,955.46,,0.002,0.001,428.823,0.059,0.064,0.0337,7218.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-03",16,15.45,3275.2,,0.007,0.001,1364.862,0.059,0.069,0.0074,22965.91,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-04",17,16.41,3407.38,,0.007,0.001,1427.043,0.059,0.075,0.0081,24012.468,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-05",16,15.17,2958.59,,0.006,0.001,1253.93,0.059,0.064,0.0078,21096.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-06",15,14.62,2784.26,,0.006,0.001,1183.346,0.059,0.069,0.0083,19911.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-07",16,15.12,3312.18,,0.007,0.001,1369.342,0.059,0.066,0.0093,23042.051,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-08",16,15.09,3366.93,,0.007,0.001,1384.757,0.059,0.068,0.0084,23301.193,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-09",19,17.81,4187.48,,0.009,0.001,1700.758,0.059,0.078,0.0085,28618.194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-10",20,19.12,4377.84,,0.009,0.001,1794.541,0.059,0.076,0.0068,30198.088,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-11",18,16.93,3644.76,,0.008,0.001,1528.949,0.059,0.069,0.0089,25725.645,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-12",19,17.92,3821.82,,0.008,0.001,1597.395,0.0591,0.077,0.0079,26880.971,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-13",17,16.15,3720.95,,0.008,0.001,1547.29,0.059,0.07,0.0082,26037.53,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-14",11,9.76,2407.86,,0.005,0.001,1001.774,0.0591,0.054,0.0096,16853.589,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-15",10,9.07,1581.07,,0.003,0.001,685.339,0.0591,0.045,0.0095,11532.723,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-16",19,17.24,3766.28,,0.008,0.001,1555.863,0.0591,0.08,0.0084,26179.523,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-17",24,24,4926,,0.01,0.001,2055.4,0.059,0.067,0.0039,34582.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-18",16,14.13,2692.16,,0.006,0.001,1147.163,0.0591,0.062,0.0106,19304.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-19",9,8.07,1715.07,,0.004,0.001,720.354,0.059,0.054,0.0102,12123.413,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-20",24,24,4817,,0.01,0.001,2021.6,0.059,0.064,0.0038,34014.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-21",11,9.9,2131.44,,0.005,0.001,894.536,0.059,0.052,0.0116,15051.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-22",9,7.39,1395.03,,0.003,0.001,596.17,0.059,0.05,0.0198,10030.453,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-23",21,19.83,4068.08,,0.009,0.001,1706.64,0.059,0.077,0.0082,28723.012,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-24",24,24,5809,,0.012,0.001,2422,0.059,0.089,0.0043,40752.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-25",23,22.03,4505.03,,0.009,0.001,1875.495,0.059,0.067,0.0041,31557.179,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-26",16,13.94,2985.21,,0.006,0.001,1277.272,0.0591,0.082,0.0136,21491.167,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-27",13,10.1,1571.82,,0.004,0.001,713.294,0.0592,0.066,0.0141,12001.565,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-01",10,9.75,1956.75,,0.004,0.001,840.1,0.059,0.07,0.02,14134.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-02",17,16.03,3138.03,,0.007,0.001,1336.404,0.0591,0.068,0.0065,22489.617,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-03",3,2.82,410.22,,0.001,0.001,188.31,0.059,0.008,0.005,3168.578,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-04",14,12.15,2316.6,,0.005,0.001,1008.275,0.059,0.085,0.0156,16966.925,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-05",17,16.11,3361.15,,0.007,0.001,1411.504,0.0591,0.074,0.0091,23748.938,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-06",23,22.12,4730.5,,0.01,0.001,1984.384,0.059,0.088,0.0066,33392.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-07",2,1.78,240.02,,0.001,0.001,113.616,0.059,0.005,0.006,1911.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-10",22,21.75,3760.5,,0.008,0.001,1644.85,0.059,0.102,0.0107,27679.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-11",16,15.2,2829.82,,0.006,0.001,1239.278,0.059,0.064,0.0099,20854.458,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-12",13,12.11,2755.74,,0.006,0.001,1134.538,0.059,0.062,0.0098,19090.571,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-13",11,9.89,1703.01,,0.004,0.001,750.492,0.059,0.051,0.0088,12630.612,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-14",16,15.01,3126.78,,0.007,0.001,1312.525,0.059,0.07,0.009,22086.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-15",15,13.16,2488.16,,0.005,0.001,1064.144,0.059,0.063,0.0133,17903.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-22",7,6.35,1091.3,,0.002,0.001,489.165,0.059,0.051,0.0336,8233.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-23",17,15.9,3810.38,,0.008,0.001,1576.866,0.059,0.074,0.0074,26534.868,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-24",16,14.78,3510.92,,0.007,0.001,1451.175,0.059,0.065,0.0078,24418.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-25",19,17.93,4509.4,,0.009,0.001,1870.602,0.059,0.079,0.0063,31476.221,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-26",14,12.17,2875.37,,0.006,0.001,1200.282,0.0591,0.065,0.0095,20195.514,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-27",12,10.8,2498.76,,0.005,0.001,1044.86,0.0591,0.057,0.0129,17581.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-28",19,18.7,4664.94,,0.01,0.001,1913.854,0.059,0.08,0.0062,32204.338,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-29",18,17.03,3961.02,,0.008,0.001,1624.114,0.059,0.073,0.0076,27330.027,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-04-30",8,6.23,1228.98,,0.003,0.001,523.19,0.0591,0.04,0.016,8803.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-01",7,5.95,1298.3,,0.003,0.001,553.005,0.059,0.038,0.0157,9304.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-02",6,5.98,1245.28,,0.003,0.001,527.962,0.059,0.042,0.0132,8884.226,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-03",7,6,1301.38,,0.003,0.001,553.664,0.059,0.04,0.0149,9318.328,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-04",10,8.59,2189.96,,0.005,0.0009,926.242,0.059,0.054,0.014,15584.419,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-05",13,12.4,2889.65,,0.006,0.001,1214.68,0.059,0.061,0.0086,20439.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-06",13,11.8,2657.38,,0.006,0.001,1128.871,0.059,0.058,0.0107,18995.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-07",19,17.9,4105.18,,0.009,0.001,1732.218,0.059,0.075,0.0059,29149.574,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-08",13,12.07,2815.36,,0.006,0.001,1181.867,0.0591,0.057,0.0098,19886.048,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-09",12,10.19,2426.51,,0.005,0.001,1015.476,0.0591,0.054,0.0095,17086.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-10",9,8.6,1765.34,,0.004,0.001,748.609,0.059,0.046,0.0089,12597.038,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-11",16,14.48,3049.89,,0.007,0.001,1313.684,0.059,0.072,0.0109,22107.283,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-12",17,14.42,2868.47,,0.006,0.001,1219.359,0.0591,0.081,0.0135,20517.898,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-13",7,6.77,1492.82,,0.003,0.001,623.89,0.059,0.043,0.0134,10502.009,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-14",8,5.98,1225.74,,0.003,0.001,519.396,0.0593,0.038,0.0143,8739.579,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-15",6,5.83,1278.74,,0.003,0.001,537.166,0.059,0.035,0.0122,9037.633,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-16",14,12.55,2672.79,,0.006,0.001,1121.042,0.0591,0.057,0.0104,18858.941,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-17",9,7.83,1946.32,,0.004,0.001,821.031,0.0591,0.046,0.0142,13814.613,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-18",8,6.27,1110.25,,0.002,0.001,483.717,0.059,0.04,0.0155,8138.836,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-19",8,6.3,1079.05,,0.002,0.001,488.43,0.059,0.04,0.0215,8218.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-20",6,5.18,1013.24,,0.002,0.001,434.624,0.059,0.04,0.0235,7312.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-21",9,7.2,1736.76,,0.004,0.001,737.512,0.059,0.047,0.009,12410.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-22",7,5.83,1368.62,,0.003,0.001,584.07,0.059,0.038,0.0134,9827.889,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-23",8,7.87,1795.34,,0.004,0.001,751.431,0.059,0.044,0.0101,12643.606,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-24",12,10.85,2340.08,,0.005,0.001,983.809,0.059,0.046,0.0077,16555.646,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-25",16,14.83,3141.57,,0.007,0.001,1314.473,0.059,0.058,0.0071,22117.156,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-26",14,13.3,3417.18,,0.007,0.001,1430.799,0.059,0.064,0.0075,24076.412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-27",11,9.33,2242.15,,0.005,0.001,934.316,0.059,0.048,0.0102,15723.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-28",13,12.8,3086.8,,0.006,0.001,1266.46,0.059,0.061,0.0078,21309.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-29",19,17.86,4290.36,,0.009,0.001,1762.116,0.059,0.077,0.0069,29648.868,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-30",14,13.3,3242.7,,0.007,0.001,1342.075,0.059,0.063,0.0068,22581.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-05-31",15,13.87,2950.88,,0.006,0.001,1245.237,0.0591,0.059,0.0075,20954.471,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-01",24,24,6033,,0.012,0.001,2460.6,0.059,0.09,0.0043,41402.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-02",24,24,6059,,0.012,0.001,2469.1,0.059,0.087,0.0042,41549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-03",20,19.01,4467.5,,0.009,0.001,1871.101,0.059,0.08,0.0068,31483.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-04",12,11.1,2404.5,,0.005,0.001,994.835,0.059,0.047,0.0084,16738.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-05",15,14.14,3014.77,,0.006,0.001,1244.747,0.059,0.06,0.0087,20943.533,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-06",8,6.29,1128.73,,0.002,0.001,486.495,0.0591,0.036,0.0191,8185.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-07",6,5.83,1289.91,,0.003,0.001,532.917,0.059,0.038,0.0128,8967.115,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-08",11,9.87,2357.47,,0.005,0.001,988.402,0.0591,0.052,0.0114,16628.771,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-09",19,17.86,4530.39,,0.01,0.001,1883.933,0.0591,0.081,0.0074,31700.421,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-10",15,14.59,3715.62,,0.008,0.001,1561.751,0.059,0.073,0.0072,26278.109,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-11",14,13.07,3165.8,,0.007,0.001,1308.12,0.059,0.058,0.0075,22009.007,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-12",16,15.82,3661.14,,0.008,0.001,1501.918,0.059,0.068,0.0071,25273.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-13",8,6.83,1545.79,,0.003,0.001,650.457,0.059,0.042,0.0143,10944.798,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-14",8,6.82,981.46,,0.003,0.001,620.64,0.059,0.038,0.0129,10441.664,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-15",18,16.63,2918.57,,0.008,0.001,1515.041,0.059,0.065,0.0083,25492.441,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-16",7,5.23,1054.17,,0.002,0.001,443.909,0.0591,0.035,0.0147,7469.872,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-17",12,11.88,2268.5,,0.005,0.001,970.16,0.059,0.05,0.0078,16324.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-20",10,9.12,1745,,0.004,0.001,770.112,0.059,0.09,0.03,12959.996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-21",11,9.77,2223.41,,0.005,0.001,909.712,0.059,0.052,0.0114,15307.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-22",14,12.97,3353.61,,0.007,0.001,1379.658,0.059,0.068,0.0095,23213.821,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-23",24,24,6158,,0.013,0.001,2525,0.059,0.097,0.0046,42487.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-24",24,24,6491,,0.013,0.001,2649.2,0.059,0.102,0.0046,44576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-25",12,11,2554.3,,0.005,0.001,1075.912,0.059,0.062,0.0098,18107.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-26",14,12.83,3236.83,,0.007,0.001,1327.013,0.0591,0.065,0.0101,22331.086,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-27",18,17.07,4329.9,,0.009,0.001,1768.827,0.059,0.087,0.0074,29759.613,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-28",15,14,3264.88,,0.007,0.001,1330.698,0.059,0.071,0.0089,22392.936,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-29",16,15.45,3509.45,,0.007,0.001,1437.45,0.059,0.076,0.0079,24185.805,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-06-30",15,14.39,3263.63,,0.007,0.001,1352.545,0.059,0.08,0.0088,22758.887,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-01",11,9.8,2421.74,,0.005,0.001,1002.633,0.059,0.054,0.0134,16875.265,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-02",18,17.97,4281.05,,0.009,0.001,1752.327,0.059,0.08,0.0063,29486.91,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-03",19,18.24,4623.33,,0.01,0.001,1893.555,0.059,0.087,0.0067,31861.444,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-04",13,12.53,2869.4,,0.006,0.001,1205.133,0.059,0.064,0.0079,20275.362,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-05",16,15.15,3863.17,,0.008,0.001,1597.4,0.059,0.086,0.0085,26873.895,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-06",16,13.78,3383.26,,0.007,0.001,1395.761,0.0591,0.076,0.0125,23486.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-07",11,10.98,2716.28,,0.006,0.001,1123.786,0.059,0.06,0.0089,18909.636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-08",24,24,5613,,0.012,0.001,2289.8,0.059,0.084,0.0043,38526.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-09",14,13.27,3159.24,,0.007,0.001,1305.149,0.059,0.079,0.0103,21960.233,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-10",15,13.9,3475.94,,0.007,0.001,1453.204,0.059,0.078,0.0087,24451.964,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-11",16,15.4,3855.4,,0.008,0.001,1617.9,0.059,0.084,0.0076,27222.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-12",16,15.52,3968,,0.008,0.001,1646.204,0.059,0.076,0.0071,27695.932,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-13",19,17.97,4532.98,,0.009,0.001,1876.725,0.059,0.081,0.0067,31578.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-14",13,11.8,2760.94,,0.006,0.001,1137.192,0.0591,0.06,0.0099,19132.889,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-15",24,24,5551,,0.011,0.001,2267.3,0.059,0.09,0.0047,38151.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-16",24,24,5503,,0.011,0.001,2250.1,0.059,0.082,0.0043,37861.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-17",12,11.75,2674.58,,0.006,0.001,1111.396,0.059,0.058,0.0078,18700.045,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-18",15,13.47,3206.09,,0.007,0.001,1316.166,0.059,0.066,0.0106,22148.087,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-19",14,13.82,3195.62,,0.007,0.001,1303.816,0.059,0.068,0.0077,21939.002,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-20",15,13.97,3292.03,,0.007,0.001,1362.752,0.059,0.073,0.0094,22930.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-21",24,24,5655,,0.012,0.001,2341.7,0.059,0.091,0.0046,39402.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-22",19,18.21,4076.33,,0.008,0.001,1678.433,0.059,0.085,0.0084,28242.431,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-23",18,17.28,4073.96,,0.008,0.001,1675.724,0.059,0.084,0.0088,28198.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-24",17,15.99,3932.56,,0.008,0.001,1616.493,0.059,0.085,0.0101,27201.248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-25",16,14.89,3716.64,,0.008,0.001,1521.068,0.059,0.079,0.0107,25596.519,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-26",17,15.75,3947.39,,0.008,0.001,1614.26,0.059,0.083,0.0116,27162.521,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-27",24,24,6206,,0.013,0.001,2542.1,0.059,0.094,0.0044,42775.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-28",24,24,5702,,0.012,0.001,2321.7,0.059,0.088,0.0045,39070.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-29",16,15.06,3638.72,,0.008,0.001,1507.49,0.0591,0.074,0.0088,25365.538,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-30",24,24,5984,,0.012,0.001,2450.5,0.059,0.091,0.0044,41230.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-07-31",24,24,5955,,0.012,0.001,2462.9,0.059,0.088,0.0042,41440.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-01",16,15.15,3537.03,,0.007,0.001,1459.762,0.059,0.07,0.0068,24561.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-02",11,10.13,2425.36,,0.005,0.001,999.554,0.059,0.055,0.0092,16820.809,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-03",12,10.95,2569.93,,0.005,0.001,1058.425,0.059,0.057,0.0092,17808.402,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-04",12,10.75,2542.47,,0.005,0.0009,1036.622,0.059,0.054,0.0105,17444.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-05",11,8.83,1985.58,,0.004,0.001,827.77,0.0592,0.051,0.016,13927.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-06",8,7.82,1567.78,,0.003,0.001,660.284,0.059,0.046,0.0121,11110.876,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-07",11,10.28,2483.52,,0.005,0.001,1023.3,0.059,0.064,0.0105,17221.308,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-08",18,17.02,4221.48,,0.009,0.001,1720.042,0.059,0.091,0.0079,28941.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-09",19,17.89,4497.28,,0.009,0.001,1838.853,0.0591,0.095,0.0086,30940.723,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-10",20,19,4724,,0.01,0.001,1927.71,0.059,0.094,0.0078,32436.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-11",24,24,5819,,0.012,0.001,2346.9,0.059,1.492,0.0759,39491.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-12",13,11.84,2913.56,,0.006,0.001,1205.286,0.059,0.063,0.009,20282.157,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-13",14,12.76,3321.59,,0.007,0.001,1399.878,0.059,0.073,0.0094,23555.783,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-14",24,24,5410,,0.012,0.001,2289.1,0.059,0.084,0.0043,38521,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-15",24,24,4967,,0.011,0.001,2086.4,0.059,0.075,0.0042,35108.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-16",24,24,4573,,0.01,0.001,1917.4,0.059,0.069,0.0043,32266.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-17",24,24,5465,,0.011,0.001,2267.2,0.059,0.081,0.0043,38147.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-18",24,24,4512,,0.01,0.001,1934.9,0.059,0.075,0.0046,32556.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-19",24,24,5272,,0.011,0.001,2215.7,0.059,0.086,0.0046,37286.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-20",24,24,4485,,0.01,0.001,1906.5,0.059,0.06,0.0037,32078.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-21",24,24,4660,,0.01,0.001,1951.2,0.059,0.068,0.0041,32829.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-22",24,24,4510,,0.01,0.001,1894,0.059,0.065,0.0039,31871.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-23",24,24,4797,,0.01,0.001,1987.4,0.059,0.067,0.0039,33445.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-24",20,18.92,4481.95,,0.009,0.001,1854.454,0.059,0.094,0.0103,31199.559,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-25",24,24,4768,,0.01,0.001,1990.7,0.059,0.073,0.0043,33498.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-26",23,22.98,4283.3,,0.009,0.001,1802.804,0.059,0.066,0.0043,30337.386,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-27",13,12.77,3148.45,,0.007,0.001,1324.956,0.059,0.064,0.0079,22294.284,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-28",14,13.37,2904.95,,0.006,0.001,1201.612,0.059,0.059,0.0107,20221.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-29",8,6.8,1269.52,,0.003,0.0009,541.562,0.059,0.04,0.0151,9113.682,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-30",7,5.82,1088.42,,0.002,0.001,464.758,0.059,0.038,0.0166,7820.742,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-08-31",11,9.19,1750.06,,0.004,0.0009,738.891,0.059,0.047,0.0166,12432.187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-01",10,8.82,1893.27,,0.004,0.001,779.408,0.0591,0.056,0.0151,13114.775,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-02",9,7.44,1633.8,,0.003,0.001,676.605,0.0591,0.046,0.011,11385.441,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-03",13,11.37,2558.87,,0.005,0.001,1060.421,0.059,0.059,0.0088,17840.412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-04",14,13.82,3141.52,,0.007,0.001,1313.086,0.059,0.059,0.0066,22095.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-05",24,24,5103,,0.011,0.001,2202.4,0.059,0.064,0.0035,37055,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-06",24,24,5512,,0.012,0.001,2354.4,0.059,0.078,0.0038,39620,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-07",24,24,5018,,0.01,0.001,2074.9,0.059,0.065,0.0036,34913.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-08",24,24,4063,,0.009,0.001,1746.5,0.059,0.045,0.0028,29386.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-09",24,24,5484,,0.012,0.001,2291.4,0.059,0.085,0.0043,38553.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-10",24,24,5528,,0.011,0.001,2250.6,0.059,0.087,0.0045,37872.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-11",18,17.08,3980.74,,0.008,0.001,1618.092,0.059,0.084,0.0075,27227.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-12",19,18.72,4421.07,,0.009,0.001,1813.353,0.059,0.085,0.0065,30511.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-13",18,16.91,3695.43,,0.008,0.001,1512.476,0.059,0.072,0.007,25452.463,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-14",24,24,5742,,0.012,0.001,2347.6,0.059,0.084,0.0043,39501.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-15",24,24,5821,,0.012,0.001,2400.1,0.059,0.091,0.0045,40382.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-16",24,24,5503,,0.012,0.001,2288.8,0.059,0.092,0.0048,38515.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-17",24,24,5015,,0.011,0.001,2085.7,0.059,0.072,0.0041,35096.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-18",24,24,5160,,0.011,0.001,2154,0.059,0.085,0.0047,36248.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-19",24,24,4605,,0.01,0.001,1946.4,0.059,0.066,0.004,32753.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-20",24,24,3682,,0.008,0.001,1683.2,0.059,0.046,0.0033,28323.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-21",24,24,4017,,0.009,0.001,1727.8,0.059,0.04,0.0028,29078.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-22",1,0.07,0.49,,0,0.001,1.4,0.06,0,0.016,23.513,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-23",14,13.07,2712,,0.006,0.001,1159.174,0.059,0.055,0.0085,19504.627,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-24",22,21.22,4942.48,,0.01,0.001,2074.518,0.059,0.077,0.0054,34905.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-25",20,18.45,4013.69,,0.008,0.001,1675.504,0.059,0.077,0.0091,28192.142,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-26",11,10.73,2095.56,,0.004,0.001,883.908,0.059,0.048,0.0094,14872.274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-27",18,16.75,3232.61,,0.007,0.0009,1362.891,0.0591,0.065,0.0089,22931.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-28",23,22.93,5372.96,,0.011,0.001,2206.72,0.059,0.085,0.0046,37130.901,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-29",10,9.23,2104.12,,0.005,0.001,899.03,0.059,0.049,0.008,15127.177,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-09-30",13,12.87,3088.91,,0.007,0.001,1313.297,0.059,0.068,0.0076,22100.306,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-01",19,18.26,4122.08,,0.009,0.001,1773.41,0.059,0.096,0.0085,29841.108,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-02",24,24,5891,,0.012,0.001,2427.9,0.059,0.075,0.0037,40854.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-03",24,24,6051,,0.013,0.001,2491.1,0.059,0.078,0.0038,41922.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-04",11,9.75,2161.15,,0.005,0.001,894.73,0.059,0.051,0.0145,15055.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-05",24,24,6231,,0.013,0.001,2594.3,0.059,0.081,0.0037,43658.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-06",24,24,6248,,0.013,0.001,2569,0.059,0.08,0.0037,43227.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-07",24,24,6303,,0.013,0.001,2570.4,0.059,0.08,0.0037,43248.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-08",24,24,6029,,0.012,0.001,2424.6,0.059,0.078,0.0038,40800.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-09",24,24,6098,,0.012,0.001,2458.3,0.059,0.08,0.0039,41366.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-10",24,24,5867,,0.012,0.001,2362.1,0.059,0.076,0.0038,39745.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-11",13,11.15,2458.35,,0.005,0.001,1006.2,0.059,0.057,0.0087,16934.385,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-12",22,21.57,5313.28,,0.011,0.001,2207.238,0.059,0.118,0.0086,37144.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-13",23,22.33,5260.02,,0.011,0.001,2162.373,0.059,0.102,0.0058,36385.773,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-14",16,15.73,3776.88,,0.008,0.001,1569.207,0.059,0.103,0.0107,26404.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-15",20,19.82,4743.94,,0.01,0.001,1942.552,0.059,0.119,0.0086,32686.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-16",24,24,5346,,0.011,0.001,2183,0.059,0.1,0.0054,36727.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-17",24,24,5642,,0.012,0.001,2280.4,0.059,0.111,0.0058,38371.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-18",12,10.42,2365.89,,0.005,0.001,965.229,0.0591,0.064,0.0144,16241.187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-19",20,18.62,4338.62,,0.009,0.001,1765.012,0.059,0.1,0.0097,29698.657,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-20",21,19.77,4664.01,,0.01,0.001,1900.865,0.059,0.112,0.0103,31987.157,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-21",24,24,5863,,0.012,0.001,2380.1,0.059,0.117,0.0058,40049.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-22",24,24,6446,,0.013,0.001,2630.2,0.059,0.129,0.0058,44254.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-23",24,24,5906,,0.012,0.001,2372.8,0.059,0.107,0.0054,39923.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-24",24,24,5880,,0.012,0.001,2356,0.059,0.107,0.0054,39640.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-25",21,20.09,4733.97,,0.01,0.001,1923.706,0.059,0.119,0.0091,32370.196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-26",24,24,6170,,0.013,0.001,2500.6,0.059,0.121,0.0058,42076.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-27",24,24,5618,,0.011,0.001,2267.8,0.059,0.105,0.0055,38162.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-28",18,17.42,4153.52,,0.009,0.001,1687.464,0.059,0.11,0.0099,28397.066,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-29",19,17.85,4327.29,,0.009,0.001,1753.584,0.059,0.11,0.0107,29509.645,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-30",18,17.7,4220.16,,0.009,0.001,1713.112,0.059,0.105,0.0096,28826.854,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-10-31",20,18.95,4472.3,,0.009,0.001,1806.36,0.059,0.114,0.0106,30400.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-01",16,15.28,3691.32,,0.008,0.001,1488.57,0.059,0.096,0.0131,25050.904,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-02",24,24,6211,,0.013,0.001,2501,0.059,0.125,0.0059,42086.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-03",19,17.8,4097.8,,0.008,0.001,1665.772,0.059,0.101,0.0122,28030.868,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-04",11,9.58,2205.63,,0.005,0.001,905.199,0.0591,0.065,0.0174,15231.514,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-05",14,12.43,2948.45,,0.006,0.001,1227.822,0.059,0.081,0.0185,20662.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-06",19,18.28,3562.17,,0.009,0.001,1763.813,0.059,0.112,0.0096,29680.656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-07",1,0.33,23.1,,0,0.001,18.447,0.059,0.003,0.021,310.365,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-11",13,11.48,2276.12,,0.005,0.001,966.418,0.0591,0.124,0.0341,16260.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-12",19,18.08,3901.6,,0.008,0.001,1606.97,0.059,0.109,0.013,27038.288,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-13",10,7.8,1558.75,,0.003,0.001,654.775,0.0591,0.066,0.0245,11017.041,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-14",8,7.02,1589,,0.003,0.001,656.118,0.059,0.063,0.0201,11039.566,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-15",18,16.98,3892.47,,0.008,0.001,1581.722,0.059,0.081,0.0106,26618.248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-16",24,24,5790,,0.012,0.001,2357.8,0.059,0.079,0.004,39673.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-17",12,10.62,2284.36,,0.005,0.001,937.161,0.0591,0.06,0.0166,15767.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-18",11,8.73,1774.79,,0.004,0.001,745.329,0.059,0.054,0.0201,12540.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-19",8,7.37,1629.69,,0.003,0.001,673.104,0.059,0.056,0.0228,11325.793,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-20",19,17.41,4102.07,,0.008,0.001,1665.624,0.059,0.089,0.0094,28026.899,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-21",19,17.7,4216.04,,0.009,0.001,1705.51,0.059,0.088,0.01,28697.09,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-22",24,24,5871,,0.012,0.001,2354.4,0.059,0.081,0.0041,39618.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-23",13,12.18,2740.1,,0.006,0.001,1131.974,0.059,0.058,0.0095,19046.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-24",24,24,5990,,0.012,0.001,2420.9,0.059,0.081,0.004,40736.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-25",17,14.82,3473.82,,0.007,0.001,1412.718,0.059,0.08,0.015,23770.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-26",6,5.95,1336.9,,0.003,0.001,552.645,0.059,0.054,0.017,9298.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-27",16,14.26,3286.08,,0.007,0.001,1334.456,0.0591,0.082,0.0104,22456.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-28",16,14.15,3357.48,,0.007,0.001,1358.009,0.0591,0.079,0.0119,22852.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-29",1,0.1,10.7,,0,0.001,3.36,0.059,0.001,0.042,56.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-04",8,6.99,1179.63,,0.003,0.001,530.801,0.059,0.044,0.0123,8932.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-05",10,8.82,1958.37,,0.004,0.001,807.236,0.059,0.064,0.0202,13584.006,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-06",11,9.73,2056.69,,0.004,0.001,853.343,0.059,0.064,0.0175,14360.478,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-07",10,8.75,1934.4,,0.004,0.001,804.125,0.059,0.055,0.0178,13528.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-08",24,24,5510,,0.011,0.001,2255.4,0.059,0.077,0.004,37953.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-09",20,18.67,4168.27,,0.009,0.001,1715.706,0.059,0.086,0.0097,28866.777,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-10",9,8.7,1835.1,,0.004,0.001,771.23,0.059,0.059,0.0169,12975.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-11",11,10.13,2256.59,,0.005,0.001,934.495,0.059,0.067,0.0133,15723.326,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-12",13,12.25,2785,,0.006,0.001,1160.025,0.059,0.076,0.0136,19519.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-13",12,10.31,2245.99,,0.005,0.001,932.974,0.059,0.073,0.0209,15699.487,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-14",12,9.87,2073.95,,0.004,0.001,870.535,0.059,0.065,0.0202,14646.217,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-15",16,14.44,3144.22,,0.007,0.001,1308.244,0.059,0.102,0.0175,22015.894,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-16",19,18.29,4311.92,,0.009,0.001,1768.026,0.059,0.095,0.0096,29751.347,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-17",19,17,3731.8,,0.008,0.001,1539.94,0.0591,0.073,0.0108,25912.03,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-18",15,13.51,2880.27,,0.006,0.001,1213.46,0.0591,0.085,0.0153,20418.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-19",11,9.92,2197.74,,0.005,0.001,914.259,0.0591,0.058,0.0132,15384.013,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-20",11,9.77,2244.61,,0.005,0.001,930.507,0.059,0.053,0.013,15654.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-21",24,24,5241,,0.011,0.001,2144,0.059,0.071,0.004,36073,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-22",18,15.59,3344.35,,0.007,0.001,1411.769,0.0591,0.101,0.0165,23755.997,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-23",18,15.87,3442.82,,0.007,0.001,1452.254,0.059,0.087,0.0129,24437.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-24",24,23.17,5343.82,,0.011,0.001,2189.054,0.059,0.078,0.0047,36837.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-25",6,4.9,984.6,,0.002,0.001,417.33,0.059,0.041,0.0233,7024.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-26",5,4.45,752.8,,0.002,0.001,331.75,0.059,0.034,0.0276,5580.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-27",8,7.1,1444.6,,0.003,0.001,608.38,0.059,0.044,0.0145,10236.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-28",8,7.12,1515.37,,0.003,0.001,638.278,0.059,0.052,0.0153,10740.383,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-29",17,16.17,3421.43,,0.007,0.001,1425.054,0.059,0.074,0.0083,23980.182,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-30",8,6.99,1412.34,,0.003,0.001,599.716,0.059,0.05,0.016,10091.094,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-1",,"2020-12-31",9,7.12,1436.65,,0.003,0.001,610.277,0.059,0.05,0.0152,10268.749,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-07",14,12.5,1241.94,,0.004,0.001,709.008,0.0591,0.131,0.0414,11929.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-13",7,5.15,651.19,,0.002,0.001,313.916,0.0591,0.042,0.0363,5282.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-20",6,5.07,977.5,,0.002,0.001,428.083,0.059,0.065,0.0353,7203.998,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-23",21,20.05,2776.91,,0.007,0.001,1327.116,0.059,0.125,0.0181,22327.665,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-24",16,15.3,2934.6,,0.006,0.001,1243.37,0.059,0.068,0.0079,20920.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-27",7,5.26,831.94,,0.002,0.001,375.513,0.059,0.055,0.0379,6319.822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-28",15,14.71,2405.14,,0.005,0.001,1072.278,0.059,0.071,0.0105,18043.423,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-29",8,5.51,809.35,,0.002,0.001,377.972,0.0591,0.045,0.0264,6360.476,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-09",1,0.02,0,,0,0.001,0.202,0.06,0,0,3.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-10",19,17.26,2414.11,,0.006,0.001,1189.062,0.0591,0.155,0.0259,20006.214,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-11",16,13,2488.22,,0.005,0.001,1072.814,0.0591,0.062,0.0094,18050.978,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-12",4,3.48,271.52,,0.001,0.001,177.5,0.059,0.049,0.0523,2986.972,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-13",21,20.05,4338.34,,0.009,0.001,1848.477,0.059,0.074,0.0061,31106.627,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-14",20,19.07,3875.91,,0.008,0.001,1643.311,0.0591,0.068,0.0066,27650.102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-15",18,16.27,2944.58,,0.006,0.001,1272.203,0.0591,0.06,0.0078,21404.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-17",17,15.99,2927.16,,0.007,0.001,1291.576,0.059,0.098,0.016,21730.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-19",17,15.25,3053.23,,0.007,0.001,1304.169,0.059,0.08,0.0104,21943.259,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-20",19,17.3,3149.18,,0.007,0.001,1358.92,0.059,0.07,0.0102,22865.73,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-21",3,2.03,287.03,,0.001,0.001,129.686,0.059,0.006,0.0187,2182.181,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-24",1,0.48,7.2,,0,0.001,15.168,0.059,0.023,0.177,255.072,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-25",24,24,4763,,0.01,0.001,2075.4,0.059,0.133,0.012,34924.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-26",18,16.65,3084.86,,0.007,0.001,1322.374,0.059,0.066,0.0063,22252.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-27",13,11.32,2272.72,,0.005,0.001,963.312,0.059,0.057,0.0144,16208.926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-28",8,7.28,1204.28,,0.003,0.001,527.596,0.059,0.044,0.0141,8878.934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-02",12,11.23,1795.76,,0.004,0.001,838.577,0.059,0.166,0.0551,14112.528,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-03",17,16.4,3451.64,,0.007,0.001,1438.644,0.059,0.064,0.0061,24204.996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-04",18,17.41,3604.51,,0.008,0.001,1507.356,0.059,0.056,0.0046,25364.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-05",19,18.14,3566.98,,0.008,0.001,1511.122,0.059,0.062,0.0057,25429.132,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-06",18,17.38,3242.86,,0.007,0.001,1397.639,0.059,0.067,0.0072,23519.014,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-07",17,16.25,3488.63,,0.007,0.001,1447.301,0.059,0.061,0.0065,24352.894,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-08",18,16.3,3570.55,,0.007,0.001,1474.167,0.059,0.063,0.0086,24803.789,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-09",20,19.02,4399.69,,0.009,0.001,1787.212,0.0591,0.073,0.0065,30074.716,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-10",21,20.3,4573.28,,0.009,0.001,1874.872,0.059,0.062,0.004,31547.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-11",19,18.03,3849.5,,0.008,0.001,1610.847,0.059,0.062,0.0066,27104,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-12",21,19.6,4209.22,,0.009,0.001,1755.038,0.059,0.063,0.0053,29533.768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-13",24,24,5111,,0.011,0.001,2152.4,0.059,0.07,0.0039,36220.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-14",11,10.95,2602.35,,0.005,0.001,1087.835,0.059,0.059,0.0094,18302.215,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-15",17,16.03,2970.03,,0.007,0.001,1288.237,0.059,0.063,0.0081,21677.099,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-16",20,18.35,3964.48,,0.008,0.001,1640.991,0.059,0.064,0.0067,27615.055,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-17",24,24,4922,,0.01,0.001,2049.9,0.059,0.066,0.0038,34492.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-18",19,16.32,3103.07,,0.007,0.001,1326.049,0.0591,0.065,0.0106,22311.665,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-19",10,9.95,1955.4,,0.004,0.001,847.005,0.059,0.054,0.011,14253.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-20",24,24,4812,,0.01,0.001,2012,0.059,0.07,0.0041,33857.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-21",12,11,2327.35,,0.005,0.001,978.045,0.059,0.059,0.0108,16458.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-22",12,11,2260.06,,0.005,0.0009,955.419,0.059,0.061,0.0101,16075.242,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-23",22,20.81,4269.09,,0.009,0.001,1787.271,0.059,0.075,0.0071,30074.218,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-24",24,24,5840,,0.012,0.001,2426.4,0.059,0.091,0.0044,40827.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-25",22,21.98,4497.4,,0.009,0.001,1866.82,0.059,0.068,0.0043,31409.604,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-26",22,21.88,4909.68,,0.01,0.001,2066.5,0.059,0.082,0.005,34774.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-27",21,20,3761.56,,0.008,0.001,1641.52,0.059,0.07,0.0079,27619.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-01",14,13.97,2298.49,,0.005,0.001,1056.389,0.059,0.112,0.0222,17773.596,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-02",18,17.15,3322.1,,0.007,0.001,1417.379,0.0591,0.071,0.0088,23850.859,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-03",18,16.52,3561.21,,0.008,0.001,1532.717,0.0591,0.077,0.0073,25792.252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-04",20,19.55,4047.35,,0.009,0.001,1743.395,0.059,0.078,0.0062,29334.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-05",18,17.2,3592.15,,0.008,0.001,1503.425,0.059,0.071,0.0077,25298.695,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-06",24,24,5208,,0.011,0.001,2171.3,0.059,0.079,0.0043,36535.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-07",14,12.25,2497.33,,0.006,0.001,1091.778,0.059,0.069,0.0161,18370.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-08",19,18.08,3944.96,,0.008,0.001,1671.964,0.059,0.086,0.0089,28134.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-09",24,24,5301,,0.011,0.001,2251.6,0.059,0.082,0.0043,37887,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-10",24,24,4488,,0.01,0.001,1928.1,0.059,0.069,0.0042,32443.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-11",11,10.54,1871.25,,0.004,0.001,807.452,0.059,0.047,0.0081,13587.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-12",16,14.13,3142.88,,0.007,0.001,1301.31,0.059,0.069,0.0088,21897.498,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-13",19,17.35,3304.36,,0.007,0.001,1430.104,0.059,0.072,0.0105,24065.783,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-14",17,16,3309.55,,0.007,0.001,1387.887,0.059,0.067,0.008,23354.244,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-15",16,14.18,2667.4,,0.006,0.001,1138.804,0.0591,0.069,0.0139,19165.328,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-22",12,11.97,1603.52,,0.004,0.001,805.425,0.059,0.111,0.0286,13550.011,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-23",18,16.99,3996.6,,0.008,0.001,1652.566,0.0591,0.076,0.0067,27807.507,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-24",18,16.77,3941.6,,0.008,0.001,1630.589,0.059,0.075,0.0078,27436.498,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-25",20,19.08,4712,,0.01,0.001,1951.012,0.059,0.077,0.0054,32827.236,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-26",15,13.32,3061.8,,0.006,0.001,1284,0.059,0.065,0.0097,21604.882,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-27",14,12.29,2738.22,,0.006,0.001,1153.741,0.0591,0.059,0.0141,19412.389,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-28",20,19.9,4921.88,,0.01,0.001,2016.622,0.059,0.079,0.0049,33934.666,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-29",19,18.25,4169.95,,0.009,0.001,1711.453,0.059,0.067,0.0052,28797.953,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-04-30",11,9.61,2007.32,,0.004,0.001,859.285,0.0591,0.053,0.0105,14459.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-01",10,8.15,1732.4,,0.004,0.001,740.675,0.059,0.049,0.013,12462.09,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-02",9,8.22,1680.62,,0.004,0.001,718.066,0.059,0.059,0.0199,12082.546,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-03",9,7.99,1651.23,,0.004,0.001,707.962,0.059,0.047,0.012,11912.064,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-04",11,9.99,2471.14,,0.005,0.001,1043.773,0.059,0.059,0.0099,17562.889,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-05",14,13.64,3111.77,,0.007,0.001,1307.561,0.059,0.065,0.0071,22003.809,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-06",14,13.04,2867.44,,0.006,0.001,1215.916,0.059,0.066,0.0077,20457.302,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-07",11,10.72,2627.6,,0.006,0.001,1090.088,0.059,0.058,0.0091,18343.532,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-08",15,13.32,3025.14,,0.006,0.001,1273.146,0.059,0.062,0.0101,21424.238,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-09",13,12.07,2821.4,,0.006,0.001,1180.42,0.0591,0.059,0.0097,19859.353,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-10",11,9.81,1947.89,,0.004,0.001,834.203,0.059,0.053,0.0145,14039.175,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-11",5,4.88,1058.56,,0.002,0.001,446.852,0.059,0.036,0.014,7520.004,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-12",21,19.45,4195.94,,0.009,0.001,1763.381,0.059,0.075,0.007,29669.387,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-13",16,14.87,2967.26,,0.006,0.001,1278.34,0.0591,0.066,0.0073,21511.441,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-14",10,7.27,1452.79,,0.003,0.0009,622.09,0.0591,0.045,0.017,10468.185,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-15",8,7.97,1698.27,,0.004,0.001,717.102,0.059,0.046,0.011,12067.756,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-16",15,13.97,2970.87,,0.006,0.0009,1245.78,0.0591,0.065,0.0079,20962.807,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-17",10,9.02,2150.37,,0.005,0.001,909.196,0.0591,0.054,0.0134,15300.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-18",10,8.21,1341.39,,0.003,0.001,607.404,0.0591,0.047,0.0152,10218.506,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-20",9,7.84,1390.31,,0.003,0.001,625.163,0.059,0.052,0.0141,10519.424,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-21",15,13.03,2741.22,,0.006,0.001,1185.202,0.0591,0.064,0.0106,19941.633,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-22",9,7.12,1556.05,,0.003,0.001,668.357,0.059,0.052,0.0157,11246.516,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-23",10,9.07,1990,,0.004,0.001,837.111,0.059,0.052,0.0098,14083.698,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-24",13,12.07,2538,,0.005,0.001,1068.162,0.0591,0.058,0.0075,17973.509,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-25",17,15.91,3329.43,,0.007,0.001,1392.164,0.059,0.061,0.0076,23426.521,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-26",15,14.55,3610.64,,0.008,0.001,1518.389,0.059,0.068,0.0069,25550.051,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-27",12,10.55,2441.42,,0.005,0.001,1018.372,0.059,0.057,0.01,17138.111,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-28",16,15.85,3620.6,,0.008,0.001,1499.87,0.059,0.069,0.0069,25237.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-29",20,18.8,4465.98,,0.009,0.001,1834.265,0.059,0.072,0.0056,30865.326,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-30",16,14.42,3432.1,,0.007,0.001,1423.067,0.059,0.068,0.0065,23945.901,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-05-31",16,15.03,3147.09,,0.007,0.001,1327.523,0.059,0.063,0.0073,22336.498,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-01",24,24,6044,,0.012,0.001,2461.1,0.059,0.092,0.0045,41413,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-02",24,24,6078,,0.012,0.001,2472.4,0.059,0.084,0.004,41602.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-03",21,20.17,4692.61,,0.01,0.001,1963.416,0.059,0.07,0.0045,33037.812,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-04",14,13.32,2848.31,,0.006,0.001,1184.034,0.059,0.059,0.0074,19923.481,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-05",16,15.12,3193.18,,0.007,0.001,1319.395,0.059,0.064,0.0086,22202.787,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-06",10,8.07,1373.83,,0.003,0.001,603.61,0.059,0.043,0.0181,10158.483,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-07",9,8.23,1703.91,,0.004,0.001,718.629,0.059,0.048,0.0183,12092.043,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-08",12,11.08,2549.2,,0.005,0.001,1070.434,0.059,0.06,0.0113,18009.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-09",20,19,4655.66,,0.01,0.001,1942.836,0.059,0.08,0.0063,32696.248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-10",16,15.73,3886.57,,0.008,0.001,1634.36,0.059,0.072,0.0063,27501.794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-11",16,15.83,3739.41,,0.008,0.001,1539.156,0.059,0.071,0.0069,25899.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-12",18,17.03,3863.6,,0.008,0.001,1589.081,0.059,0.061,0.0045,26741.922,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-13",9,8.05,1791.27,,0.004,0.001,753.738,0.059,0.046,0.0109,12682.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-14",10,8.27,1175.69,,0.004,0.001,724.374,0.0591,0.045,0.0172,12189.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-15",19,17.6,3033.66,,0.008,0.001,1591.999,0.0591,0.057,0.0053,26791.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-16",9,6.65,1326.44,,0.003,0.001,565.816,0.059,0.044,0.0186,9522.824,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-17",8,6.99,1431.3,,0.003,0.001,601.236,0.059,0.046,0.0098,10115.105,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-19",9,8.08,1572.07,,0.004,0.001,725.672,0.059,0.063,0.0197,12210.653,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-21",11,10.07,2186,,0.005,0.001,904.658,0.0591,0.063,0.0125,15221.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-22",15,14.03,3521.88,,0.007,0.001,1452.945,0.059,0.067,0.0077,24450.947,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-23",18,17.45,4103.65,,0.008,0.001,1664.8,0.059,0.078,0.0068,28017.545,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-24",24,24,6113,,0.013,0.001,2479.6,0.059,0.085,0.0041,41723.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-25",24,24,6087,,0.013,0.001,2555.9,0.059,0.095,0.0044,43009.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-26",24,24,6151,,0.013,0.001,2547.2,0.059,0.094,0.0044,42858.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-27",19,18.07,4475.63,,0.009,0.001,1833.62,0.059,0.075,0.0055,30853.052,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-28",16,15.09,3435.37,,0.007,0.001,1404.63,0.059,0.065,0.0071,23631.838,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-29",18,16.67,3737.71,,0.008,0.001,1538.813,0.059,0.06,0.005,25894.454,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-06-30",16,15.44,3449.62,,0.007,0.001,1432.617,0.059,0.066,0.0064,24106.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-01",12,11.02,2612.86,,0.006,0.001,1089.432,0.059,0.057,0.0109,18331.791,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-02",19,18.95,4454.63,,0.009,0.001,1826.804,0.059,0.066,0.0044,30740.326,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-03",20,19.2,4773.65,,0.01,0.001,1958.605,0.059,0.074,0.0049,32959.855,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-04",13,12.17,2537.21,,0.006,0.001,1089.99,0.059,0.052,0.0065,18340.001,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-05",17,16.17,4004.54,,0.008,0.001,1661.878,0.059,0.061,0.0046,27961.252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-06",17,15.02,3574.6,,0.007,0.001,1479.691,0.0591,0.062,0.0071,24897.875,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-07",13,12.97,3100,,0.007,0.001,1288.415,0.059,0.061,0.0072,21679.398,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-08",24,24,5586,,0.012,0.001,2280.4,0.059,0.077,0.004,38370.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-09",16,15.3,3533.85,,0.007,0.001,1468.83,0.059,0.063,0.0061,24715.095,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-10",16,14.98,3613.88,,0.008,0.001,1516.008,0.059,0.063,0.0058,25510.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-11",17,16.5,3986.6,,0.008,0.001,1674.8,0.059,0.072,0.0061,28180.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-12",17,16.62,4085,,0.009,0.001,1703.98,0.059,0.076,0.0063,28670.834,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-13",20,18.95,4657.98,,0.01,0.001,1932.658,0.059,0.074,0.0056,32520,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-14",14,12.92,2937.72,,0.006,0.0009,1215.352,0.059,0.055,0.0074,20450.372,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-15",24,24,5541,,0.011,0.001,2266.5,0.059,0.081,0.0042,38141.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-16",24,24,5488,,0.011,0.001,2247.1,0.059,0.079,0.0042,37808.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-17",15,14.65,3219.72,,0.007,0.001,1347.622,0.059,0.06,0.0067,22676.517,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-18",18,17.04,4005.4,,0.008,0.001,1654.986,0.059,0.065,0.0053,27848.926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-19",15,14.9,3371.1,,0.007,0.001,1378.94,0.059,0.064,0.0067,23205.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-20",24,24,5694,,0.012,0.001,2358.6,0.059,0.083,0.0042,39690.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-21",15,14.97,3656.03,,0.008,0.001,1514.165,0.059,0.069,0.0064,25481.884,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-22",24,24,5255,,0.011,0.001,2201.4,0.059,0.077,0.0041,37042.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-23",24,24,5375,,0.011,0.001,2237.9,0.059,0.077,0.0041,37659.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-24",24,24,5523,,0.012,0.001,2301.3,0.059,0.082,0.0043,38724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-25",19,18.02,4453.73,,0.009,0.001,1828.049,0.059,0.069,0.0051,30760.245,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-26",19,17.82,4403.42,,0.009,0.001,1804.718,0.059,0.079,0.0075,30364.306,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-27",24,24,6228,,0.013,0.001,2549.6,0.059,0.09,0.0042,42903.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-28",24,24,5692,,0.012,0.001,2321.1,0.059,0.084,0.0043,39055.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-29",18,16.55,3862.1,,0.008,0.001,1618.11,0.059,0.066,0.0076,27228.957,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-30",24,24,5965,,0.012,0.001,2446.8,0.059,0.087,0.0042,41172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-07-31",24,24,5938,,0.012,0.001,2457.5,0.059,0.089,0.0043,41354.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-01",24,24,5275,,0.011,0.001,2204.7,0.059,0.076,0.004,37095.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-02",14,13.28,3013.16,,0.006,0.001,1259.16,0.059,0.057,0.0067,21187.634,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-03",15,14.1,3220.05,,0.007,0.001,1334.482,0.059,0.064,0.0069,22456.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-04",13,11.99,2705.14,,0.006,0.001,1115.53,0.0591,0.059,0.0086,18770.811,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-05",12,10.05,2159.58,,0.005,0.001,906.934,0.0591,0.049,0.0087,15259.835,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-06",10,9.15,1767.8,,0.004,0.001,753.095,0.059,0.047,0.0162,12669.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-07",12,11.46,2653.86,,0.006,0.001,1102.858,0.059,0.058,0.0083,18558.186,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-08",19,18,4363.6,,0.009,0.001,1787.4,0.059,0.067,0.0047,30078.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-09",20,18.92,4647.02,,0.01,0.001,1907.424,0.0591,0.073,0.0055,32098.486,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-10",21,20.02,4910.58,,0.01,0.001,2010.1,0.059,0.075,0.0045,33821.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-11",24,24,5815,,0.012,0.001,2352.2,0.059,0.086,0.0043,39577.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-12",15,14.04,3285.38,,0.007,0.001,1373.02,0.059,0.066,0.0072,23104.642,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-13",17,15.91,3999.19,,0.009,0.001,1707.087,0.0591,0.073,0.0062,28729.063,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-14",24,24,5364,,0.012,0.001,2280.3,0.059,0.082,0.0043,38367.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-15",24,24,4954,,0.011,0.001,2086.9,0.059,0.072,0.004,35119.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-16",24,24,4547,,0.01,0.001,1912.8,0.059,0.059,0.0036,32183.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-17",24,24,5428,,0.011,0.001,2261.5,0.059,0.074,0.0038,38055.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-18",24,24,4483,,0.01,0.001,1927.5,0.059,0.068,0.0041,32430.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-19",24,24,5239,,0.011,0.001,2208.5,0.059,0.077,0.0041,37163.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-20",24,24,4457,,0.01,0.001,1899.7,0.059,0.058,0.0036,31967,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-21",24,24,4622,,0.01,0.001,1942.4,0.059,0.064,0.0038,32685.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-22",24,24,4490,,0.01,0.001,1891.9,0.059,0.062,0.0038,31833.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-23",24,23.82,4716.14,,0.01,0.001,1969.646,0.059,0.067,0.004,33140.588,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-24",21,19.95,4587.49,,0.01,0.001,1920.497,0.059,0.083,0.01,32313.424,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-25",24,24,4766,,0.01,0.001,1993.8,0.059,0.061,0.0036,33551,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-26",23,22.98,4284.3,,0.009,0.001,1806.304,0.059,0.061,0.004,30392.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-27",14,13.88,3317.4,,0.007,0.001,1401.18,0.059,0.055,0.0051,23575.628,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-28",15,14.52,3045.08,,0.006,0.001,1279.196,0.059,0.059,0.0092,21524.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-29",11,10.02,1838.02,,0.004,0.0009,808.82,0.059,0.048,0.0098,13610.732,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-30",11,9.99,1857.2,,0.004,0.001,801.059,0.059,0.047,0.0091,13479.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-08-31",14,13,2418.52,,0.005,0.0009,1035.492,0.059,0.054,0.0086,17425.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-01",13,11.89,2509.63,,0.005,0.001,1048.441,0.059,0.064,0.0125,17645.216,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-02",11,10.35,2228.07,,0.005,0.001,932.041,0.059,0.048,0.0077,15683.064,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-03",15,14.98,3277.8,,0.007,0.001,1366.642,0.059,0.063,0.0065,22995.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-04",24,24,4826,,0.01,0.001,2068.6,0.059,0.068,0.0038,34811.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-05",24,24,4965,,0.011,0.001,2161.1,0.059,0.073,0.0039,36360.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-06",24,24,5505,,0.012,0.001,2353.1,0.059,0.086,0.0043,39597.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-07",24,24,5028,,0.01,0.001,2079.1,0.059,0.066,0.0037,34983,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-08",24,24,4061,,0.009,0.001,1744.8,0.059,0.052,0.0035,29359.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-09",24,24,5541,,0.012,0.001,2312.8,0.059,0.083,0.0042,38916.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-10",24,24,5600,,0.012,0.001,2281.9,0.059,0.088,0.0046,38395.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-11",20,19.01,4352.76,,0.009,0.001,1780.048,0.059,0.068,0.0049,29952.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-12",21,20.67,4710.66,,0.01,0.001,1934.032,0.059,0.067,0.0042,32545.122,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-13",20,18.91,4031.11,,0.008,0.001,1666.454,0.059,0.057,0.0046,28044.021,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-14",24,24,5583,,0.012,0.001,2295.1,0.059,0.081,0.0042,38618.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-15",24,24,5640,,0.012,0.001,2344.5,0.059,0.087,0.0044,39451.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-16",24,24,5426,,0.011,0.001,2268.2,0.059,0.082,0.0043,38168.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-17",24,24,5025,,0.011,0.001,2095.9,0.059,0.075,0.0042,35268.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-18",24,24,5197,,0.011,0.001,2177.5,0.059,0.075,0.0041,36642.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-19",23,21.43,4030.41,,0.009,0.001,1700.423,0.059,0.061,0.007,28610.943,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-20",24,24,3698,,0.009,0.001,1692.6,0.059,0.058,0.0041,28482,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-21",24,24,4080,,0.009,0.001,1752.9,0.059,0.06,0.004,29496.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-22",11,9.69,1589.95,,0.004,0.001,709.671,0.059,0.041,0.0092,11941.186,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-24",8,7.22,1495.86,,0.003,0.001,623.956,0.059,0.042,0.01,10498.392,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-25",14,12.14,2596.64,,0.005,0.001,1081.726,0.059,0.062,0.0127,18203.792,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-26",12,12,2318,,0.005,0.001,982.5,0.059,0.052,0.0076,16531.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-27",19,17.84,3432.5,,0.007,0.001,1449.214,0.059,0.057,0.0063,24387.158,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-28",24,24,5657,,0.012,0.001,2322,0.059,0.083,0.0043,39071.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-29",23,22.97,5154.94,,0.011,0.001,2189.688,0.059,0.078,0.0042,36844.025,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-09-30",18,17.98,4237.44,,0.009,0.001,1809.422,0.059,0.08,0.0059,30443.486,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-01",21,20.2,4465.04,,0.01,0.001,1921.064,0.059,0.071,0.0047,32326.072,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-02",24,24,5970,,0.012,0.001,2455.9,0.059,0.092,0.0045,41325.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-03",24,24,6117,,0.013,0.001,2512.8,0.059,0.092,0.0043,42281.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-04",24,24,5586,,0.012,0.001,2324.7,0.059,0.087,0.0044,39117.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-05",24,24,6551,,0.014,0.001,2700.3,0.059,0.096,0.0043,45434,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-06",24,24,6379,,0.013,0.001,2613.3,0.059,0.098,0.0045,43976.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-07",24,24,6334,,0.013,0.001,2581.9,0.059,0.093,0.0043,43444.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-08",24,24,6038,,0.012,0.001,2428.3,0.059,0.091,0.0044,40864.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-09",24,24,6135,,0.012,0.001,2471,0.059,0.093,0.0045,41579.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-10",24,24,5861,,0.012,0.001,2362.2,0.059,0.086,0.0043,39748.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-11",24,24,5170,,0.011,0.001,2169.3,0.059,0.079,0.0043,36503.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-12",24,24,6085,,0.013,0.001,2521.8,0.059,0.096,0.0045,42433.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-13",24,23.73,5641.81,,0.012,0.001,2311.084,0.059,0.089,0.0046,38889.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-14",18,17.9,4246.48,,0.009,0.001,1764.21,0.059,0.077,0.0061,29687.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-15",21,20.92,5013.8,,0.01,0.001,2051.836,0.059,0.094,0.0063,34527.684,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-16",24,24,5182,,0.011,0.001,2139.5,0.059,0.079,0.0044,36001.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-17",24,24,5557,,0.011,0.001,2258.3,0.059,0.08,0.0042,37998.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-18",16,14.28,3253.11,,0.007,0.001,1348.863,0.059,0.065,0.0119,22697.907,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-19",24,24,5457,,0.011,0.001,2240.4,0.059,0.078,0.0041,37700.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-20",24,24,5539,,0.011,0.001,2272.7,0.059,0.084,0.0043,38240.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-21",24,24,5736,,0.012,0.001,2348,0.059,0.081,0.0041,39506.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-22",24,24,6451,,0.013,0.001,2633.7,0.059,0.099,0.0045,44319.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-23",24,24,5979,,0.012,0.001,2402.8,0.059,0.088,0.0043,40430,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-24",24,24,5881,,0.012,0.001,2357.7,0.059,0.085,0.0043,39672.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-25",24,24,5567,,0.011,0.001,2275.8,0.059,0.085,0.0044,38297.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-26",24,24,6097,,0.013,0.001,2482.2,0.059,0.088,0.0042,41765.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-27",24,24,5366,,0.011,0.001,2199.9,0.059,0.078,0.0042,37015.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-28",19,18.52,4331.88,,0.009,0.001,1767.816,0.059,0.075,0.0058,29745.836,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-29",20,18.95,4492.67,,0.009,0.001,1829.288,0.059,0.07,0.005,30780.549,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-30",19,18.88,4430.68,,0.009,0.001,1804.92,0.059,0.069,0.0048,30371.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-10-31",21,20.05,4638.1,,0.01,0.001,1884.53,0.059,0.071,0.0048,31709.855,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-01",20,19.56,4618.26,,0.01,0.001,1885.066,0.059,0.073,0.005,31719.398,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-02",24,24,6264,,0.013,0.001,2520.8,0.059,0.092,0.0043,42415.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-03",21,19.65,4441.15,,0.009,0.001,1819.815,0.059,0.067,0.0051,30622.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-04",20,18.58,3873.83,,0.008,0.001,1637.032,0.059,0.061,0.0062,27544.439,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-05",15,13.65,3143.8,,0.007,0.001,1327.61,0.0591,0.061,0.0084,22339.965,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-06",20,19.18,3640.42,,0.009,0.001,1828.455,0.059,0.077,0.006,30767.221,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-07",3,2.3,154.53,,0.001,0.001,110.253,0.059,0.039,0.039,1854.871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-08",18,16.8,3169,,0.007,0.001,1400.67,0.059,0.067,0.0093,23568.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-09",7,5.4,816.68,,0.002,0.001,392.3,0.059,0.047,0.0274,6601.108,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-10",18,17.05,3449.16,,0.007,0.001,1479.365,0.059,0.07,0.0084,24894.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-11",20,19.26,4129.11,,0.009,0.001,1754.615,0.059,0.066,0.0055,29526.799,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-12",20,19.15,4275.75,,0.009,0.001,1759.12,0.059,0.066,0.0054,29599.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-13",11,9.16,1720.39,,0.004,0.001,751.693,0.059,0.048,0.0137,12648.059,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-14",9,9,1964,,0.004,0.001,825.9,0.059,0.053,0.0113,13899.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-15",19,18.03,4013.57,,0.008,0.001,1644.134,0.059,0.081,0.0088,27666.518,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-16",24,24,5629,,0.012,0.001,2314.7,0.059,0.083,0.0043,38951.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-17",13,11.85,2390.9,,0.005,0.001,1001.04,0.0591,0.056,0.0105,16844.845,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-18",12,10,1894.76,,0.004,0.001,818.032,0.059,0.054,0.0161,13765.668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-19",13,12.8,2698.8,,0.006,0.001,1138.52,0.059,0.062,0.0097,19155.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-20",20,18.67,4294.46,,0.009,0.001,1761.223,0.059,0.071,0.0062,29636.233,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-21",20,18.78,4372.02,,0.009,0.001,1783.714,0.059,0.068,0.0052,30014.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-22",24,24,5877,,0.012,0.001,2360,0.059,0.087,0.0044,39712.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-23",24,24,5622,,0.012,0.001,2356.4,0.059,0.088,0.0044,39653.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-24",24,24,5987,,0.012,0.001,2426.1,0.059,0.084,0.0041,40825.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-25",18,15.92,3657.76,,0.008,0.001,1494.656,0.0591,0.071,0.0096,25149.648,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-26",9,8.97,1893.04,,0.004,0.001,812.046,0.059,0.052,0.0118,13664.519,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-27",19,18.16,4089.21,,0.009,0.001,1683.815,0.059,0.068,0.0061,28334.099,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-28",18,16.73,3900.16,,0.008,0.001,1595.297,0.059,0.076,0.0121,26846.243,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-29",1,0.1,10.8,,0,0.001,3.48,0.059,0.001,0.028,58.59,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-04",15,13.29,1391.05,,0.004,0.001,801.411,0.0591,0.106,0.0207,13481.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-05",11,10.1,2135.66,,0.005,0.001,906.266,0.059,0.06,0.0146,15250.878,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-06",13,11.77,2273.42,,0.005,0.001,981.665,0.059,0.063,0.0135,16521.425,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-07",12,10.77,2294.33,,0.005,0.001,971.906,0.059,0.055,0.0131,16357.374,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-08",24,24,5285,,0.011,0.001,2196.4,0.059,0.084,0.0046,36957.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-09",24,23.92,5256.64,,0.011,0.001,2186.416,0.059,0.077,0.0043,36794.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-10",11,10.72,2094.6,,0.005,0.001,913.248,0.059,0.049,0.0111,15367.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-11",14,13.17,2804.43,,0.006,0.001,1180.693,0.059,0.06,0.0085,19870.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-12",14,13.52,2902.27,,0.006,0.001,1228.248,0.059,0.065,0.0082,20667.378,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-13",13,11.76,2409.93,,0.005,0.001,1033.804,0.0591,0.055,0.0116,17395.919,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-14",13,11.85,2340.2,,0.005,0.001,1007.394,0.059,0.056,0.0108,16953.171,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-15",21,19.74,4056.78,,0.009,0.001,1721.08,0.059,0.069,0.0072,28960.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-16",20,19.3,4523.97,,0.009,0.001,1863.209,0.059,0.078,0.0064,31352.045,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-17",20,18.83,3976.06,,0.008,0.001,1658.391,0.059,0.071,0.0067,27907.793,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-18",20,18.8,3791.2,,0.008,0.001,1626.976,0.0591,0.072,0.0074,27378.332,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-19",18,15.61,3183.69,,0.007,0.001,1364.558,0.059,0.067,0.0089,22961.961,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-20",12,10.92,2407.84,,0.005,0.001,1007.236,0.059,0.057,0.0112,16946.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-21",24,24,4936,,0.01,0.001,2063.4,0.059,0.073,0.0042,34722,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-22",22,20.78,4336.94,,0.009,0.001,1841.74,0.059,0.07,0.006,30991.59,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-23",24,24,5213,,0.011,0.001,2200.1,0.059,0.075,0.0041,37017.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-24",24,23.18,5387.56,,0.011,0.001,2209.24,0.059,0.083,0.005,37174.782,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-25",8,7,1403.8,,0.003,0.001,602.14,0.059,0.048,0.0173,10131.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-26",9,8.82,1741.42,,0.004,0.001,759.682,0.059,0.05,0.0126,12783.654,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-27",10,9.22,1841.86,,0.004,0.001,785.312,0.059,0.049,0.0115,13214.028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-28",10,9.16,1895.12,,0.004,0.001,809.04,0.059,0.055,0.0125,13614.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-29",19,18.08,3788.53,,0.008,0.001,1588.477,0.059,0.068,0.0066,26731.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-30",10,9.1,1802.44,,0.004,0.001,772.538,0.059,0.052,0.0119,13001.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Otay Mesa Energy Center, LLC",55345,"CTG-2",,"2020-12-31",11,9.25,1854.78,,0.004,0.001,792.712,0.059,0.053,0.012,13337.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-01",3,2.13,447.91,,0.001,0.001,189.284,0.059,0.01,0.0133,3184.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-02",12,11.75,2632.75,,0.006,0.001,1152.725,0.059,0.1,0.0165,19398.375,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-03",24,24,5716,,0.012,0.001,2396.3,0.059,0.12,0.006,40323.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-04",19,16.68,3481.7,,0.008,0.001,1486.248,0.059,0.09,0.0103,25008.115,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-05",11,10.6,2500.4,,0.006,0.001,1113.66,0.059,0.089,0.0174,18737.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-06",24,24,5559,,0.012,0.001,2325.4,0.059,0.119,0.0061,39129.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-07",24,24,5440,,0.012,0.001,2278.3,0.059,0.116,0.006,38340,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-08",24,24,5485,,0.012,0.001,2303.5,0.059,0.118,0.0061,38761.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-09",24,24,5643,,0.012,0.001,2384.3,0.059,0.122,0.0061,40119.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-10",24,24,5830,,0.012,0.001,2432.8,0.059,0.127,0.0062,40934.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-11",13,11.47,2117.28,,0.005,0.001,988.937,0.059,0.078,0.0176,16644.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-12",14,12.35,2668.45,,0.006,0.001,1157.91,0.059,0.088,0.0154,19484.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-13",20,19.17,4270.46,,0.009,0.001,1813.009,0.059,0.109,0.009,30505.438,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-14",24,24,5339,,0.011,0.001,2236,0.059,0.117,0.0062,37626.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-15",24,24,5613,,0.012,0.001,2348.8,0.059,0.122,0.0062,39526.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-16",24,24,5764,,0.012,0.001,2405.4,0.059,0.13,0.0064,40476.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-17",24,24,5633,,0.012,0.001,2359.7,0.059,0.129,0.0065,39705.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-18",24,24,5603,,0.012,0.001,2355,0.059,0.127,0.0065,39621.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-19",18,16.97,4261.06,,0.009,0.001,1796.029,0.0591,0.111,0.0105,30222.453,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-20",9,6.59,1435.84,,0.003,0.001,627.72,0.059,0.064,0.0173,10563.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-21",20,19.97,4152.18,,0.009,0.001,1754.562,0.059,0.108,0.0084,29521.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-22",24,24,5150,,0.011,0.001,2169.6,0.059,0.109,0.006,36508.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-23",12,10.52,2437.48,,0.005,0.001,1039.35,0.059,0.08,0.0115,17489.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-24",12,9.47,1887.04,,0.004,0.001,835.189,0.0591,0.086,0.0153,14053.306,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-29",5,4.08,750.8,,0.002,0.001,345.425,0.059,0.077,0.0374,5811.718,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-30",19,16.75,3699.97,,0.008,0.001,1622.732,0.059,0.118,0.0133,27304.998,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-01-31",23,21.18,4748.08,,0.01,0.001,2046.01,0.059,0.112,0.0082,34430.448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-01",1,0.35,51.45,,0,0.001,23.1,0.059,0.001,0.007,388.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-07",9,8.28,1939.52,,0.004,0.001,827.828,0.0591,0.091,0.025,13928.536,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-08",2,1.35,223.1,,0.001,0.001,102.31,0.059,0.006,0.009,1721.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-09",8,7.17,1674.51,,0.004,0.001,717.03,0.059,0.085,0.0265,12063.283,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-10",18,16.43,3561.55,,0.008,0.001,1511.155,0.059,0.101,0.0088,25431.519,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-11",11,9.45,2214.9,,0.005,0.001,961.805,0.059,0.081,0.0135,16183.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-12",19,17.43,4095.55,,0.009,0.001,1740.614,0.059,0.12,0.0091,29286.627,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-13",19,17.38,4301.44,,0.009,0.001,1816.486,0.059,0.12,0.0087,30568.742,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-14",16,15.76,3884.35,,0.008,0.001,1633.183,0.059,0.109,0.0094,27480.785,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-15",16,15.2,3379.3,,0.007,0.001,1435.455,0.059,0.094,0.0098,24153.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-16",7,4.82,852.4,,0.002,0.001,393.536,0.0591,0.05,0.0221,6623.487,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-17",8,7.92,1938.68,,0.004,0.001,818.532,0.059,0.077,0.0176,13775.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-18",24,24,5583,,0.012,0.001,2339.5,0.059,0.129,0.0065,39364.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-19",18,17.21,4405.79,,0.009,0.001,1847.964,0.059,0.121,0.0094,31094.987,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-20",19,18.33,4389.03,,0.009,0.001,1873.436,0.059,0.116,0.0088,31525.957,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-21",2,1.6,296.6,,0.001,0.001,134.94,0.059,0.008,0.0075,2270.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-22",7,5.25,1012.08,,0.002,0.001,472.611,0.059,0.067,0.032,7954.093,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-24",9,8.17,2001.51,,0.004,0.001,870.004,0.059,0.087,0.0226,14639.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-25",18,17.7,4165.75,,0.009,0.001,1785.76,0.059,0.108,0.0087,30045.975,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-26",10,9.2,2260.54,,0.005,0.001,977.425,0.059,0.078,0.0136,16445.805,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-27",17,16.2,3683.1,,0.008,0.001,1565.03,0.059,0.095,0.0091,26333.965,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-28",11,10.18,2083.25,,0.005,0.001,912.837,0.059,0.073,0.0136,15360.036,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-02-29",2,1.33,218.78,,0.001,0.001,100.558,0.059,0.006,0.009,1692.548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-01",7,5.54,957.46,,0.002,0.001,427.795,0.0591,0.067,0.0327,7198.171,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-02",15,14.52,3212.4,,0.007,0.001,1364.588,0.059,0.096,0.0101,22965.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-03",17,16.31,3755.07,,0.008,0.001,1593.163,0.059,0.104,0.0093,26807.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-04",17,16.31,3763.93,,0.008,0.001,1601.269,0.059,0.1,0.0086,26943.377,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-05",17,16.35,3768.8,,0.008,0.001,1614.09,0.059,0.104,0.0089,27161.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-06",17,16.26,3975.24,,0.009,0.001,1688.711,0.059,0.106,0.0089,28417.521,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-07",2,1.33,251.44,,0.001,0.001,113.887,0.059,0.007,0.009,1916.108,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-08",2,0.3,2.5,,0,0.001,8.248,0.059,0.009,0.0885,138.846,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-23",8,7.22,1546.88,,0.003,0.001,672.68,0.059,0.048,0.0141,11319.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-24",18,17.05,3645.35,,0.008,0.001,1550.505,0.059,0.099,0.0102,26089.465,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-25",18,17.18,3658.72,,0.008,0.001,1564.248,0.059,0.104,0.0102,26321.275,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-26",2,1.87,395.33,,0.001,0.001,171.037,0.059,0.01,0.0075,2877.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-27",9,8.75,1814.75,,0.004,0.001,805.175,0.059,0.086,0.0209,13552.65,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-28",24,24,6608,,0.014,0.001,2831.6,0.059,0.145,0.0061,47644.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-29",1,0.08,0,,0,0.001,2.672,0.06,0.001,0.051,44.896,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-30",9,8.08,1643.08,,0.004,0.001,755.268,0.059,0.082,0.0232,12708.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-03-31",9,7.76,1320.84,,0.003,0.001,606.036,0.059,0.07,0.0298,10197.956,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-01",9,7.92,1749.46,,0.004,0.001,792.382,0.059,0.075,0.0218,13332.046,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-02",9,8.82,1777.36,,0.004,0.001,792.006,0.059,0.078,0.0181,13325.522,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-03",23,20.85,4395.88,,0.01,0.001,1905.526,0.059,0.107,0.0109,32063.047,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-04",20,17.67,3966.62,,0.009,0.001,1725.542,0.0591,0.11,0.0092,29033.468,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-05",17,15.93,4058.5,,0.009,0.001,1715.455,0.059,0.109,0.0085,28866.006,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-06",24,24,6315,,0.013,0.001,2618.8,0.059,0.144,0.0065,44062.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-07",24,24,5278,,0.011,0.001,2200.7,0.059,0.108,0.0059,37034.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-08",17,16.53,4347.09,,0.009,0.001,1784.079,0.059,0.087,0.0058,30021.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-12",2,0.52,2.6,,0,0.001,12.952,0.059,0.01,0.093,217.819,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-01",4,2.91,276.56,,0.001,0.001,158.835,0.059,0.053,0.0403,2673.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-02",16,15.18,3892.9,,0.008,0.001,1601.258,0.059,0.084,0.0085,26946.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-03",24,24,6434,,0.013,0.001,2649.6,0.059,0.132,0.0059,44583.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-04",24,24,5973,,0.013,0.001,2497.7,0.059,0.123,0.0058,42030.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-05",22,20.7,4602,,0.01,0.001,1953.36,0.059,0.109,0.0068,32868.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-06",1,0.62,118.42,,0,0.001,48.67,0.059,0.005,0.011,819.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-08",11,10.62,2023.32,,0.005,0.001,924.284,0.059,0.101,0.0226,15554.344,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-09",15,13.22,2997.23,,0.007,0.001,1310.538,0.059,0.114,0.0193,22054.121,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-10",24,24,5928,,0.013,0.001,2514.8,0.059,0.124,0.0058,42317.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-11",24,24,5846,,0.012,0.001,2473.4,0.059,0.126,0.006,41618.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-12",10,8.7,1949.7,,0.004,0.001,850.83,0.059,0.071,0.0212,14315.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-13",3,2.08,431.08,,0.001,0.001,189.7,0.059,0.013,0.033,3191.072,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-14",9,7.9,1557.44,,0.004,0.001,713.316,0.059,0.075,0.026,12003.278,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-16",11,9.9,1991.9,,0.004,0.001,887.364,0.059,0.087,0.0224,14933.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-17",9,8.93,1979.21,,0.004,0.001,849.41,0.059,0.07,0.0127,14292.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-18",17,15.46,3316.84,,0.007,0.001,1458.642,0.059,0.097,0.0154,24543.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-19",24,24,5701,,0.012,0.001,2436.5,0.059,0.118,0.0058,40997.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-20",15,13.35,2809.13,,0.006,0.001,1221.647,0.059,0.084,0.0093,20559.586,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-21",9,8.25,1764.2,,0.004,0.001,762.481,0.059,0.064,0.0142,12828.757,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-22",24,24,5428,,0.012,0.001,2329.2,0.059,0.123,0.0063,39193.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-23",24,24,6188,,0.013,0.001,2666.2,0.059,0.159,0.007,44862.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-24",24,24,5832,,0.013,0.001,2483.8,0.059,0.131,0.0063,41798.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-25",24,24,5455,,0.012,0.001,2300.5,0.059,0.116,0.006,38708.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-26",18,16.88,4153.2,,0.009,0.001,1761.228,0.059,0.105,0.0117,29631.188,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-27",10,9.13,1997.42,,0.005,0.001,901.355,0.059,0.068,0.0132,15164.392,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-28",1,0.35,22.75,,0,0.001,18.2,0.059,0.002,0.016,306.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-29",11,9.88,2048.48,,0.005,0.001,924.772,0.059,0.09,0.0226,15562.636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-06-30",11,10.83,2284.67,,0.005,0.001,1023.436,0.059,0.079,0.0135,17217.842,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-01",15,13.48,3174.2,,0.007,0.001,1382.296,0.059,0.097,0.0186,23261.732,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-02",14,12.56,2796.48,,0.006,0.001,1221.92,0.059,0.089,0.0191,20559.128,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-03",12,10.41,2367.96,,0.005,0.001,1035.105,0.059,0.081,0.0237,17417.374,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-04",8,6.52,1297.68,,0.003,0.001,600.116,0.059,0.072,0.0274,10096.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-05",9,8.82,1886.62,,0.004,0.001,839.446,0.059,0.082,0.0193,14127.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-06",24,24,5271,,0.011,0.001,2248.5,0.059,0.112,0.0059,37835.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-07",24,24,5039,,0.011,0.001,2152.2,0.059,0.11,0.0061,36212.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-08",24,24,4906,,0.011,0.001,2105.2,0.059,0.106,0.006,35422.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-09",24,24,5131,,0.011,0.001,2183.4,0.059,0.11,0.006,36738.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-10",24,24,5321,,0.011,0.001,2263.8,0.059,0.114,0.006,38092.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-11",24,24,5482,,0.012,0.001,2329.9,0.059,0.117,0.006,39205.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-12",24,24,5417,,0.012,0.001,2318.1,0.059,0.117,0.006,39005,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-13",24,24,5091,,0.011,0.001,2167.7,0.059,0.11,0.006,36470.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-14",24,24,5093,,0.011,0.001,2180.7,0.059,0.11,0.006,36694.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-15",24,24,4982,,0.011,0.001,2142.2,0.059,0.106,0.0059,36051.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-16",24,24,4789,,0.01,0.001,2070.7,0.059,0.104,0.006,34846.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-17",24,24,5115,,0.011,0.001,2192.5,0.059,0.111,0.006,36893.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-18",24,24,5216,,0.011,0.001,2221.7,0.059,0.112,0.006,37384.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-19",17,15.36,3179.68,,0.007,0.001,1387.4,0.0591,0.091,0.0146,23347.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-20",22,20.35,4375.35,,0.01,0.001,1882.186,0.059,0.103,0.0105,31671.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-21",24,24,5318,,0.011,0.001,2269.6,0.059,0.115,0.006,38187.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-22",24,24,5006,,0.011,0.001,2137,0.059,0.108,0.006,35958.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-23",24,24,5043,,0.011,0.001,2162.7,0.059,0.108,0.006,36393.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-24",24,24,6504,,0.014,0.001,2778.8,0.059,0.14,0.006,46757.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-25",17,15.27,3522.2,,0.008,0.001,1490.594,0.059,0.098,0.0131,25083.307,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-26",19,17.27,4097.1,,0.009,0.001,1745.831,0.0591,0.11,0.0116,29375.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-27",24,24,5585,,0.012,0.001,2342.7,0.059,0.116,0.0059,39422.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-28",24,24,5372,,0.012,0.001,2283.4,0.059,0.113,0.0059,38421.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-29",24,24,5709,,0.012,0.001,2393.7,0.059,0.122,0.006,40276.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-30",24,24,5742,,0.012,0.001,2403.4,0.059,0.12,0.0059,40439.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-07-31",24,24,5528,,0.012,0.001,2308.3,0.059,0.124,0.0064,38845,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-01",24,24,5327,,0.011,0.001,2238.3,0.059,0.131,0.007,37660.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-02",24,24,5500,,0.012,0.001,2305.8,0.059,0.132,0.0068,38803.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-03",24,24,5217,,0.011,0.001,2192,0.059,0.123,0.0067,36888.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-04",24,24,5081,,0.011,0.001,2190.9,0.059,0.126,0.0068,36865.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-05",24,24,4911,,0.011,0.001,2157,0.059,0.126,0.007,36297.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-06",22,20.16,3779,,0.008,0.001,1650.408,0.059,0.101,0.0111,27769.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-07",14,12.64,2606.95,,0.006,0.001,1147.71,0.059,0.086,0.0192,19311.402,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-08",17,15.33,3360,,0.007,0.001,1479.918,0.0591,0.097,0.0146,24902.31,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-09",17,15.31,3436.46,,0.008,0.001,1496.771,0.059,0.098,0.0151,25186.722,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-10",23,21.21,4686,,0.01,0.001,2037.078,0.059,0.111,0.01,34277.024,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-11",24,24,5141,,0.011,0.001,2236.1,0.059,0.113,0.006,37627.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-12",24,24,5578,,0.012,0.001,2394.2,0.059,0.119,0.0059,40287.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-13",24,24,6237,,0.013,0.001,2613.8,0.059,0.131,0.006,43983.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-14",24,24,6281,,0.013,0.001,2623.6,0.059,0.13,0.0059,44143.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-15",24,24,6154,,0.013,0.001,2586.4,0.059,0.13,0.006,43520,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-16",24,24,6495,,0.014,0.001,2721.8,0.059,0.137,0.006,45800.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-17",24,24,6507,,0.014,0.001,2731.5,0.059,0.138,0.006,45964,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-18",24,24,6322,,0.013,0.001,2650.3,0.059,0.134,0.006,44592.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-19",24,24,6009,,0.013,0.001,2525.3,0.059,0.133,0.0063,42492.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-20",24,24,5617,,0.012,0.001,2327.8,0.059,0.135,0.0069,39168.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-21",24,24,6342,,0.013,0.001,2631.5,0.059,0.155,0.007,44285.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-22",24,24,6144,,0.013,0.001,2549.2,0.059,0.149,0.007,42898.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-23",24,24,6051,,0.013,0.001,2509.9,0.059,0.147,0.007,42231.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-24",24,24,6400,,0.013,0.001,2667.8,0.059,0.157,0.007,44890.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-25",24,24,6037,,0.013,0.001,2506.9,0.059,0.145,0.0069,42183.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-26",24,24,5926,,0.012,0.001,2458.9,0.059,0.145,0.007,41375.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-27",24,24,5898,,0.012,0.001,2441.3,0.059,0.144,0.007,41078.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-28",24,24,5912,,0.012,0.001,2460.7,0.059,0.145,0.007,41403.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-29",24,24,6666,,0.014,0.001,2779.6,0.059,0.153,0.0065,46774.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-30",24,24,5593,,0.012,0.001,2385.6,0.059,0.14,0.007,40142.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-08-31",24,24,5711,,0.012,0.001,2392.8,0.059,0.142,0.007,40263,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-01",24,24,5632,,0.012,0.001,2407.1,0.059,0.142,0.007,40504.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-02",24,24,6690,,0.014,0.001,2835.7,0.059,0.167,0.007,47717.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-03",24,24,5953,,0.013,0.001,2502.9,0.059,0.147,0.007,42116.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-04",24,24,6030,,0.013,0.001,2526.8,0.059,0.147,0.0069,42515.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-05",24,24,5899,,0.013,0.001,2478.5,0.059,0.144,0.0069,41704.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-06",24,24,6117,,0.013,0.001,2564.4,0.059,0.148,0.0069,43153.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-07",24,24,6368,,0.013,0.001,2669.8,0.059,0.155,0.0069,44927.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-08",24,24,5957,,0.013,0.001,2488.3,0.059,0.143,0.0068,41871.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-09",24,24,5598,,0.012,0.001,2375.1,0.059,0.14,0.007,39957.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-10",15,13.45,2821.44,,0.006,0.001,1234.516,0.059,0.094,0.018,20774.081,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-11",15,13.96,2813.24,,0.006,0.001,1239.374,0.059,0.09,0.013,20853.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-12",13,11.45,2555.48,,0.006,0.001,1128.445,0.059,0.094,0.0216,18986.626,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-13",13,11.43,2473.95,,0.005,0.001,1083.077,0.059,0.096,0.022,18226.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-14",15,13.4,3107.64,,0.007,0.001,1357.868,0.059,0.092,0.0169,22850.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-15",16,14.41,3258.7,,0.007,0.001,1422.384,0.059,0.094,0.0166,23934.015,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-16",24,24,5529,,0.012,0.001,2387.3,0.059,0.121,0.006,40174.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-17",24,24,5726,,0.012,0.001,2448.5,0.059,0.138,0.0067,41202.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-18",24,24,5598,,0.012,0.001,2398.2,0.059,0.135,0.0067,40355.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-19",24,24,5156,,0.011,0.001,2252.2,0.059,0.114,0.006,37897.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-20",13,11.66,2487.54,,0.006,0.001,1104.34,0.059,0.088,0.0202,18583.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-21",14,12.25,2608.08,,0.006,0.001,1148.646,0.059,0.084,0.0167,19328.504,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-22",13,10.23,2024.18,,0.005,0.001,905.099,0.0591,0.083,0.0224,15230.565,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-23",19,18.17,3784,,0.008,0.001,1654.159,0.059,0.107,0.0089,27834.274,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-24",23,22.08,5233,,0.011,0.001,2227.036,0.059,0.115,0.0098,37474.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-25",21,20.17,4105,,0.009,0.001,1779.529,0.059,0.105,0.0076,29945.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-26",20,18.13,3782.1,,0.008,0.001,1645.962,0.059,0.105,0.0116,27698.257,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-27",19,17.16,3610,,0.008,0.001,1594.18,0.059,0.099,0.012,26826.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-28",24,24,5371,,0.012,0.001,2323.9,0.059,0.117,0.006,39103.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-29",24,24,5451,,0.012,0.001,2313.1,0.059,0.119,0.0061,38921.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-09-30",24,24,5950,,0.013,0.001,2512.3,0.059,0.126,0.0059,42275.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-01",24,24,5571,,0.012,0.001,2354.3,0.059,0.118,0.006,39616.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-02",24,24,5492,,0.012,0.001,2306.1,0.059,0.119,0.0061,38804.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-03",24,24,5587,,0.012,0.001,2379.1,0.059,0.126,0.0063,40032.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-04",15,13.55,3166.1,,0.007,0.001,1386.506,0.059,0.096,0.0171,23330.745,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-05",24,24,5781,,0.013,0.001,2480.5,0.059,0.126,0.006,41738.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-06",24,24,6294,,0.013,0.001,2627.5,0.059,0.133,0.006,44212.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-07",24,24,6064,,0.013,0.001,2515,0.059,0.127,0.006,42322.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-08",24,24,4970,,0.011,0.001,2119.4,0.059,0.11,0.0062,35659.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-09",17,15.43,3124.55,,0.007,0.001,1369.664,0.059,0.086,0.0132,23047.89,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-10",19,18.03,3683.3,,0.008,0.001,1606.542,0.059,0.102,0.0088,27032.207,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-11",21,20.35,3881.85,,0.009,0.001,1720.425,0.059,0.102,0.0088,28949.965,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-12",24,24,4914,,0.011,0.001,2138.7,0.059,0.108,0.006,35990.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-13",24,24,5201,,0.011,0.001,2241.5,0.059,0.113,0.006,37718.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-14",24,24,5659,,0.012,0.001,2390.2,0.059,0.121,0.006,40215.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-15",24,24,6298,,0.013,0.001,2654.2,0.059,0.135,0.006,44657.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-16",24,24,5450,,0.012,0.001,2302.5,0.059,0.128,0.0066,38742.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-17",24,24,5417,,0.012,0.001,2286.4,0.059,0.133,0.0069,38473.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-18",24,24,5583,,0.012,0.001,2376.5,0.059,0.138,0.0069,39994.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-19",24,24,5891,,0.013,0.001,2532.6,0.059,0.152,0.0071,42615.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-20",24,24,5564,,0.012,0.001,2377.1,0.059,0.14,0.007,40001.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-21",24,24,5992,,0.013,0.001,2539.6,0.059,0.149,0.007,42733.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-22",24,24,5454,,0.012,0.001,2306.4,0.059,0.136,0.007,38814,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-23",24,24,5523,,0.012,0.001,2308,0.059,0.136,0.007,38836.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-24",24,24,5679,,0.012,0.001,2392.3,0.059,0.147,0.0073,40260.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-25",24,24,5815,,0.013,0.001,2477.2,0.059,0.154,0.0074,41685.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-26",24,24,5916,,0.013,0.001,2492.7,0.059,0.149,0.0071,41943.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-27",24,24,6108,,0.013,0.001,2562.3,0.059,0.151,0.007,43115.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-28",24,24,5887,,0.012,0.001,2438.4,0.059,0.145,0.0071,41031.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-29",24,24,5451,,0.011,0.001,2265.8,0.059,0.131,0.0069,38126.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-30",24,24,5657,,0.012,0.001,2334.7,0.059,0.136,0.0069,39287.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-10-31",24,24,5503,,0.012,0.001,2334.5,0.059,0.141,0.0072,39283.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-01",24,24,5764,,0.012,0.001,2396.6,0.059,0.143,0.0071,40331.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-02",24,24,6396,,0.013,0.001,2653.7,0.059,0.158,0.0071,44651,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-03",24,24,6199,,0.013,0.001,2573.4,0.059,0.152,0.007,43301.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-04",24,24,6031,,0.013,0.001,2510.4,0.059,0.15,0.0071,42240.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-05",24,24,6414,,0.014,0.001,2679.7,0.059,0.158,0.007,45089.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-06",24,24,5251,,0.011,0.001,2183.9,0.059,0.13,0.0071,36743.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-07",24,24,4911,,0.011,0.001,2095.6,0.059,0.127,0.0072,35264.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-08",18,17.23,4231.47,,0.009,0.001,1805.294,0.059,0.115,0.0076,30375.474,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-09",11,10.02,2405,,0.005,0.001,1025.582,0.059,0.1,0.0132,17256.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-10",24,24,5841,,0.012,0.001,2452.1,0.059,0.153,0.0074,41262.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-11",24,24,5607,,0.012,0.001,2367,0.059,0.138,0.0069,39825.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-12",24,24,5298,,0.011,0.001,2256.3,0.059,0.135,0.0071,37969.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-13",18,15.62,3243.6,,0.007,0.001,1435.539,0.059,0.108,0.0152,24158.475,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-14",8,6.87,1290.7,,0.003,0.001,594.162,0.059,0.07,0.0235,9998.123,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-18",10,8.95,1790.95,,0.004,0.001,816.115,0.059,0.077,0.0207,13733.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-19",23,22.07,4817,,0.01,0.001,2076.875,0.059,0.134,0.008,34946.056,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-20",24,24,6072,,0.013,0.001,2505.4,0.059,0.146,0.0069,42158.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-21",14,13,3104.44,,0.007,0.001,1331.824,0.059,0.106,0.0175,22409.404,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-22",20,18.42,4277.05,,0.009,0.001,1801.059,0.059,0.127,0.0097,30304.545,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-23",24,24,5454,,0.012,0.001,2306.1,0.059,0.125,0.0064,38805.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-24",24,24,5818,,0.012,0.001,2431.2,0.059,0.136,0.0066,40912.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-25",24,24,5597,,0.012,0.001,2342.1,0.059,0.133,0.0067,39413.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-26",15,13.79,2659.51,,0.006,0.001,1184.043,0.059,0.102,0.0189,19923.036,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-27",21,19.4,4235.4,,0.009,0.001,1822.93,0.059,0.124,0.0138,30673.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-28",14,12.56,2851.32,,0.006,0.001,1233.42,0.059,0.101,0.0214,20753.864,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-29",19,17.88,4387.12,,0.01,0.001,1882.08,0.059,0.135,0.0121,31670.504,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-11-30",24,24,6055,,0.013,0.001,2571.5,0.059,0.144,0.0066,43263.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-01",24,24,6263,,0.013,0.001,2672,0.059,0.155,0.0069,44962.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-02",24,24,6154,,0.013,0.001,2552.5,0.059,0.149,0.007,42948.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-03",24,24,6308,,0.013,0.001,2623,0.059,0.154,0.007,44138.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-04",24,24,6262,,0.013,0.001,2607.2,0.059,0.152,0.0069,43869.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-05",24,24,6173,,0.013,0.001,2554.6,0.059,0.15,0.007,42984.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-06",24,24,6097,,0.013,0.001,2512.1,0.059,0.149,0.007,42275.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-07",24,24,6187,,0.013,0.001,2563.7,0.059,0.151,0.007,43140.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-08",24,24,6077,,0.013,0.001,2515.9,0.059,0.148,0.007,42337.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-09",24,24,6033,,0.013,0.001,2496.5,0.059,0.142,0.0068,42009.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-10",24,24,6306,,0.013,0.001,2610.2,0.059,0.155,0.007,43918.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-11",24,24,6293,,0.013,0.001,2606.1,0.059,0.153,0.007,43850.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-12",24,24,6159,,0.013,0.001,2570.4,0.059,0.15,0.007,43251.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-13",24,24,6538,,0.014,0.001,2701.3,0.059,0.136,0.006,45450.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-14",24,24,6220,,0.013,0.001,2574.1,0.059,0.151,0.007,43312.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-15",24,24,6227,,0.013,0.001,2584.7,0.059,0.153,0.007,43491.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-16",24,24,6544,,0.014,0.001,2693.2,0.059,0.159,0.007,45316.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-17",24,24,5803,,0.012,0.001,2406.1,0.059,0.128,0.0063,40490.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-18",24,24,5656,,0.012,0.001,2355.4,0.059,0.133,0.0067,39636.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-19",24,24,5804,,0.012,0.001,2434.5,0.059,0.143,0.007,40966.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-20",21,19.27,4484.36,,0.01,0.001,1921.486,0.059,0.127,0.0117,32333.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-21",24,24,6051,,0.013,0.001,2536.2,0.059,0.139,0.0065,42677.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-22",24,24,5797,,0.012,0.001,2444.4,0.059,0.143,0.007,41135.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-23",24,24,6164,,0.013,0.001,2560.8,0.059,0.15,0.007,43092.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-24",24,24,6511,,0.014,0.001,2690.8,0.059,0.159,0.007,45280.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-25",22,20.31,4926.54,,0.01,0.001,2077.139,0.059,0.132,0.012,34956.716,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-26",21,20.09,4594.26,,0.01,0.001,1960.105,0.059,0.13,0.009,32983.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-27",24,24,6198,,0.013,0.001,2562.9,0.059,0.151,0.007,43125.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-28",24,24,6479,,0.014,0.001,2693.8,0.059,0.159,0.007,45324.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-29",24,24,6128,,0.013,0.001,2553.4,0.059,0.15,0.007,42960.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-30",24,24,5609,,0.012,0.001,2326.9,0.059,0.133,0.0068,39149.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"1",,"2020-12-31",20,18.62,4380.43,,0.009,0.001,1865.927,0.059,0.132,0.0112,31400.935,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-01",2,1.35,222.1,,0.001,0.001,102.375,0.059,0.008,0.0125,1723.355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-02",9,8.78,2139.5,,0.005,0.001,911.966,0.059,0.107,0.022,15348.482,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-03",24,24,5756,,0.012,0.001,2417.7,0.059,0.142,0.007,40680.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-04",8,7.6,1661.4,,0.004,0.001,705.72,0.059,0.043,0.0076,11875.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-05",9,8.1,2110.1,,0.005,0.001,918.54,0.0591,0.097,0.0223,15455.81,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-06",24,24,5632,,0.012,0.001,2356.6,0.059,0.14,0.007,39654.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-07",24,24,5473,,0.012,0.001,2294.7,0.059,0.131,0.0068,38609,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-08",24,24,5497,,0.012,0.001,2312.5,0.059,0.129,0.0067,38912,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-09",21,20.28,4730.12,,0.01,0.001,2014.409,0.059,0.132,0.0096,33894.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-10",24,24,5854,,0.012,0.001,2448.8,0.059,0.134,0.0065,41203.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-11",7,5.57,983.25,,0.002,0.001,446.54,0.059,0.069,0.0306,7515.319,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-12",11,9.98,2165.03,,0.005,0.001,940.186,0.059,0.091,0.0187,15821.497,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-13",24,24,5430,,0.012,0.001,2294.8,0.059,0.135,0.007,38614,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-14",24,24,5344,,0.011,0.001,2242,0.059,0.133,0.007,37723.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-15",24,24,5643,,0.012,0.001,2364,0.059,0.14,0.007,39781.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-16",24,24,5823,,0.012,0.001,2434,0.059,0.149,0.0073,40956.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-17",24,24,5656,,0.012,0.001,2371,0.059,0.139,0.007,39896.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-18",11,10.37,2136.79,,0.005,0.001,907.173,0.059,0.055,0.0079,15266.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-19",11,10.43,2335.76,,0.005,0.001,1015.244,0.059,0.097,0.0214,17084.266,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-20",24,24,5987,,0.013,0.001,2525.2,0.059,0.151,0.0071,42492,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-21",24,24,5067,,0.011,0.001,2139.3,0.059,0.129,0.0072,35996.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-22",24,24,5152,,0.011,0.001,2173.6,0.059,0.127,0.007,36571.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-23",24,24,5597,,0.012,0.001,2375.4,0.059,0.141,0.007,39967.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-24",24,23.1,5077.1,,0.011,0.001,2164.14,0.059,0.135,0.0088,36414.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-27",11,10.25,2051.75,,0.005,0.001,935.7,0.0591,0.1,0.0233,15743.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-28",24,24,5215,,0.011,0.001,2253.7,0.059,0.128,0.0068,37922.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-29",24,24,5578,,0.012,0.001,2396,0.059,0.14,0.007,40317.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-30",3,1.17,185.61,,0,0.001,84.422,0.059,0.011,0.0527,1421.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-05",3,2.78,113.96,,0.001,0.001,132.506,0.059,0.096,0.0923,2229.786,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-06",9,8.42,1619.12,,0.004,0.001,757.037,0.059,0.085,0.0247,12739.738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-07",22,20.48,4613.48,,0.01,0.001,1982.724,0.059,0.126,0.012,33359.904,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-08",11,9.44,2062.09,,0.005,0.001,898.002,0.059,0.092,0.0228,15109.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-09",10,9.82,2143.18,,0.005,0.001,952.524,0.059,0.101,0.0199,16030.748,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-10",24,23.42,4930.78,,0.011,0.001,2103.52,0.059,0.136,0.0097,35394.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-11",21,19.4,4214.4,,0.009,0.001,1826.272,0.059,0.13,0.0133,30728.392,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-12",22,20.35,4685.6,,0.01,0.001,2000.585,0.059,0.129,0.0114,33661.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-13",22,20.4,4909.1,,0.011,0.001,2091.87,0.0591,0.133,0.0116,35198.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-14",20,18.62,4564.65,,0.01,0.001,1933.059,0.0591,0.137,0.0117,32530.063,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-15",20,18.34,4055.68,,0.009,0.001,1733.576,0.059,0.123,0.0125,29168.302,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-16",11,9.03,1745.89,,0.004,0.001,787.837,0.059,0.081,0.0229,13256.373,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-17",18,15.38,3320.1,,0.007,0.001,1439.48,0.0591,0.131,0.0158,24225.746,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-18",24,24,5614,,0.012,0.001,2354.8,0.059,0.14,0.007,39622.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-19",22,21,5235.7,,0.011,0.001,2212.855,0.059,0.14,0.0084,37234.97,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-20",24,24,5745,,0.012,0.001,2451.5,0.059,0.144,0.007,41253.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-21",19,16.93,3846.72,,0.008,0.001,1656.552,0.0591,0.127,0.0137,27874.583,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-22",2,1.1,53.9,,0,0.001,54.34,0.059,0.043,0.0955,914.265,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-23",8,6.9,1411.16,,0.003,0.001,630.592,0.059,0.081,0.0286,10610.874,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-24",18,15.5,3419.7,,0.008,0.001,1512.295,0.0591,0.119,0.0148,25447.119,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-25",22,20.24,4700.36,,0.01,0.001,2028.228,0.059,0.131,0.0103,34127.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-26",21,19.25,4339.24,,0.009,0.001,1872.736,0.059,0.124,0.0108,31516.747,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-27",21,19.24,4404.36,,0.009,0.001,1878.228,0.059,0.122,0.0105,31604.184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-28",21,19.75,4066.94,,0.009,0.001,1765.138,0.059,0.112,0.0086,29703.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-02-29",11,8.73,1711.44,,0.004,0.001,757.533,0.059,0.08,0.0261,12745.958,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-01",9,8.82,1633.82,,0.004,0.001,739.026,0.059,0.084,0.0201,12434.662,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-02",19,17.23,3827.08,,0.008,0.001,1630.751,0.0591,0.123,0.0139,27444.171,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-03",21,19.33,4389.33,,0.009,0.001,1873.571,0.059,0.128,0.012,31531.641,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-04",24,23.15,5301.15,,0.011,0.001,2268.79,0.059,0.143,0.0088,38178.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-05",21,19.22,4420.1,,0.01,0.001,1899.204,0.059,0.138,0.0114,31957.706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-06",21,19.23,4619.1,,0.01,0.001,1970.845,0.059,0.139,0.0114,33165.868,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-07",24,21.54,4739.04,,0.01,0.001,2037.693,0.059,0.129,0.0093,34284.446,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-08",12,10.69,2464.61,,0.005,0.001,1078.764,0.059,0.104,0.0213,18154.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-23",14,13.73,2317.44,,0.006,0.001,1121.438,0.059,0.134,0.0226,18870.328,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-24",22,20.22,4297.24,,0.009,0.001,1834.504,0.059,0.118,0.0095,30867.212,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-25",24,24,5119,,0.011,0.001,2180.7,0.059,0.142,0.0078,36696.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-26",17,14.58,3194.38,,0.007,0.001,1363.996,0.059,0.117,0.0182,22955.038,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-04",7,6.52,1566.84,,0.003,0.001,687.104,0.059,0.092,0.0303,11560.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-05",24,24,6341,,0.013,0.001,2671.8,0.059,0.157,0.007,44957.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-06",24,24,6353,,0.013,0.001,2649.1,0.059,0.156,0.007,44574.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-07",24,24,5277,,0.011,0.001,2203.1,0.059,0.13,0.007,37074,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-08",24,23.22,5956.36,,0.013,0.001,2484.132,0.059,0.157,0.0085,41802.282,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-09",24,24,6389,,0.014,0.001,2683.4,0.059,0.163,0.0072,45153.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-10",19,17.4,4167.85,,0.009,0.001,1770.32,0.059,0.133,0.0103,29787.98,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-11",20,18.2,3716.1,,0.008,0.001,1596.48,0.059,0.113,0.011,26864.21,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-12",18,16.34,3712.46,,0.008,0.001,1601.416,0.059,0.122,0.0139,26944.692,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-13",24,24,6094,,0.013,0.001,2568.7,0.059,0.155,0.0072,43225.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-14",24,24,6444,,0.014,0.001,2694.8,0.059,0.166,0.0073,45344.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-15",24,24,5526,,0.012,0.001,2333.6,0.059,0.145,0.0074,39258.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-16",24,23.1,5591.1,,0.012,0.001,2390.57,0.059,0.153,0.0091,40229.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-17",8,6.77,1322.14,,0.003,0.001,596.136,0.059,0.075,0.0278,10030.391,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-18",9,8.67,1764.82,,0.004,0.001,777.524,0.059,0.086,0.0206,13082.779,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-19",10,8.78,1666.48,,0.004,0.001,743.012,0.059,0.086,0.0236,12499.65,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-20",11,8.81,1550.06,,0.004,0.001,701.344,0.059,0.078,0.0254,11801.197,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-21",8,6.81,1365.93,,0.003,0.001,615.12,0.059,0.075,0.026,10350.655,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-22",9,7.75,1571.35,,0.004,0.001,698.83,0.059,0.079,0.0242,11757.09,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-23",10,8.83,1828.22,,0.004,0.001,818.877,0.059,0.088,0.0232,13778.217,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-24",9,8.23,1689.74,,0.004,0.001,761.304,0.059,0.085,0.0223,12811.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-25",8,7.07,1419.58,,0.003,0.001,650.562,0.059,0.074,0.023,10946.794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-26",9,7.85,1524.63,,0.003,0.001,688.565,0.059,0.081,0.0267,11586.219,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-27",6,5.61,1151.83,,0.003,0.001,539.259,0.059,0.063,0.0247,9076.276,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-28",9,7.72,1569.99,,0.004,0.001,721.426,0.059,0.081,0.0266,12139.844,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-29",7,6.02,996.46,,0.002,0.001,463.68,0.059,0.063,0.0264,7801.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-04-30",7,5.77,937.34,,0.002,0.001,438.897,0.059,0.065,0.0324,7383.737,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-01",7,6.19,1204.17,,0.003,0.001,547.9,0.059,0.066,0.0223,9221.304,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-04",10,9.03,1981,,0.004,0.001,886.384,0.059,0.116,0.0235,14913.686,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-05",9,7.75,1574.79,,0.004,0.001,695.443,0.059,0.079,0.0238,11702.762,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-06",8,6.81,1398.39,,0.003,0.001,639.194,0.059,0.076,0.0265,10755.154,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-07",9,8.55,1792.25,,0.004,0.001,802.45,0.059,0.086,0.0203,13500.815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-08",9,8.62,1841.39,,0.004,0.001,817.891,0.059,0.091,0.0227,13762.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-09",9,8.5,1883.9,,0.004,0.001,831.58,0.059,0.09,0.0224,13992.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-10",7,5.9,1095.3,,0.003,0.001,499.38,0.059,0.069,0.0291,8402.98,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-11",16,12.76,2582.89,,0.006,0.001,1123.739,0.059,0.112,0.0198,18909.557,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-12",7,6.23,1215.3,,0.003,0.001,543.616,0.059,0.067,0.0237,9148.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-17",5,4.3,434.5,,0.001,0.001,263.09,0.059,0.072,0.0482,4428.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-18",22,19.35,3608.3,,0.008,0.001,1577.385,0.059,0.099,0.0124,26541.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-19",8,6.73,1109.19,,0.003,0.001,512.232,0.059,0.064,0.0268,8617.084,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-20",19,17.49,3354.18,,0.007,0.001,1450.722,0.059,0.1,0.0126,24414.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-21",7,5.42,935.58,,0.002,0.001,420.06,0.059,0.045,0.0253,7067.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-25",13,12.53,2649.25,,0.006,0.001,1212.416,0.059,0.133,0.0265,20399.621,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-26",24,24,5978,,0.013,0.001,2578.8,0.059,0.161,0.0073,43395.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-27",24,24,5862,,0.013,0.001,2523.6,0.059,0.16,0.0075,42463.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-28",19,16.45,3764.38,,0.008,0.001,1644.242,0.059,0.11,0.0151,27666.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-29",14,12.24,2561.36,,0.006,0.001,1121.212,0.059,0.089,0.0152,18864.684,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-30",7,6.19,1037.17,,0.002,0.001,474.669,0.059,0.061,0.0217,7988.779,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-05-31",7,5.94,1032.42,,0.002,0.001,474.064,0.059,0.057,0.0246,7974.994,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-01",10,9.82,2037.54,,0.005,0.001,926.286,0.059,0.088,0.0172,15586.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-02",24,24,5753,,0.012,0.001,2421.9,0.059,0.13,0.0064,40753.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-03",24,24,6203,,0.013,0.001,2582.1,0.059,0.133,0.0061,43452.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-04",24,24,5988,,0.013,0.001,2495.7,0.059,0.154,0.0073,41992.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-05",15,13.55,2923.89,,0.006,0.001,1239.16,0.0591,0.101,0.0141,20851.334,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-06",7,5.79,982.72,,0.002,0.001,453.065,0.059,0.063,0.0304,7625.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-08",7,6.22,1228.1,,0.003,0.001,536.746,0.059,0.073,0.0309,9032.602,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-09",21,19.92,4650.67,,0.01,0.001,2054.887,0.059,0.149,0.0123,34578.954,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-10",24,24,6026,,0.013,0.001,2543.4,0.059,0.156,0.0073,42797.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-11",24,24,5967,,0.013,0.001,2508.4,0.059,0.16,0.0075,42207.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-12",21,17.89,3762.35,,0.008,0.001,1670.843,0.059,0.124,0.0133,28112.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-13",10,8.13,1626.17,,0.004,0.001,733.386,0.059,0.067,0.0198,12341.653,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-14",1,0.1,0,,0,0,0.01,0.043,0,0.027,0.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-15",9,7.88,1647.68,,0.004,0.001,735.752,0.059,0.083,0.0238,12380.972,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-17",14,13.78,2795.22,,0.006,0.001,1228.33,0.059,0.106,0.0147,20668.002,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-18",11,10.09,2260.68,,0.005,0.001,996.577,0.059,0.083,0.0136,16769.341,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-19",22,21.68,5001.64,,0.011,0.001,2132.72,0.059,0.122,0.0077,35887.468,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-20",21,19.35,3975.47,,0.009,0.001,1722.538,0.059,0.115,0.0115,28986.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-21",24,24,4955,,0.011,0.001,2116.3,0.059,0.123,0.0069,35609.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-22",13,12.32,2916.07,,0.006,0.001,1244.208,0.059,0.089,0.0111,20935.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-23",20,19.8,4617.96,,0.01,0.001,1962.012,0.059,0.118,0.008,33011.804,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-24",15,14.13,3357.93,,0.007,0.001,1453.984,0.059,0.111,0.0117,24466.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-25",24,24,6135,,0.013,0.001,2619,0.059,0.17,0.0077,44069.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-26",20,18.48,4468.75,,0.01,0.001,1907.106,0.059,0.132,0.0103,32093.162,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-27",14,12.19,2724.24,,0.006,0.001,1257.905,0.059,0.099,0.0139,21168.175,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-28",11,9.95,2060.4,,0.005,0.001,925.811,0.0591,0.08,0.0177,15578.259,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-29",2,1.1,174.1,,0,0.001,78.68,0.059,0.008,0.032,1323.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-06-30",8,7.9,1791.5,,0.004,0.001,777.54,0.059,0.073,0.0163,13084.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-01",11,10.18,2535.28,,0.006,0.001,1098.393,0.059,0.085,0.0137,18480.444,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-02",11,9.36,2191.46,,0.005,0.001,946.455,0.059,0.08,0.0138,15926.824,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-03",2,1.33,217.47,,0,0.001,98.339,0.059,0.007,0.012,1655.491,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-07",10,9.28,2004.8,,0.004,0.001,860.188,0.059,0.102,0.0268,14470.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-08",12,9.46,1747.84,,0.004,0.001,768.615,0.0591,0.077,0.0182,12934.456,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-09",14,12.42,2744.52,,0.006,0.001,1173.305,0.0591,0.096,0.012,19744.357,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-10",14,13.25,3100.8,,0.007,0.001,1318.55,0.059,0.09,0.0106,22188.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-11",11,10.25,2402.1,,0.005,0.001,1025.035,0.059,0.09,0.0142,17247.645,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-12",12,10.5,2489.2,,0.005,0.001,1066.495,0.0591,0.092,0.0152,17944.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-13",17,16.32,3398.73,,0.007,0.001,1444.258,0.059,0.101,0.0097,24303.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-14",11,10.32,2296.23,,0.005,0.001,977.669,0.059,0.084,0.0134,16451.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-15",11,10.33,2199.16,,0.005,0.001,943.218,0.059,0.079,0.0122,15871.727,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-16",11,10.28,1997.24,,0.004,0.001,866.33,0.059,0.073,0.0124,14580.583,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-17",11,9.87,2181.3,,0.005,0.001,935.001,0.0591,0.08,0.0119,15735.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-18",11,9.37,1993.7,,0.004,0.001,851.104,0.059,0.071,0.0125,14321.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-19",11,9.36,2011.13,,0.004,0.001,869.004,0.0591,0.076,0.013,14620.43,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-20",16,14.63,3216.86,,0.007,0.001,1372.576,0.059,0.099,0.0133,23097.404,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-21",12,11.3,2494.95,,0.005,0.001,1063.307,0.059,0.09,0.0128,17896.631,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-22",10,8.35,1706.13,,0.004,0.001,731.854,0.059,0.07,0.0143,12315.415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-23",10,8.4,1783.54,,0.004,0.001,767.489,0.059,0.072,0.0145,12913.969,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-24",11,9.35,2339.8,,0.005,0.0009,1000.245,0.059,0.083,0.0115,16830.674,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-25",11,10.32,2455.3,,0.005,0.001,1031.812,0.059,0.084,0.0122,17362.857,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-26",10,9.85,2322.44,,0.005,0.001,990.664,0.059,0.076,0.0111,16672.495,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-27",24,24,5592,,0.012,0.001,2333.1,0.059,0.127,0.0065,39262.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-28",13,12.25,2874,,0.006,0.001,1216.99,0.059,0.088,0.0112,20476.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-29",24,24,5723,,0.012,0.001,2387.3,0.059,0.122,0.0061,40167,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-30",24,24,5745,,0.012,0.001,2396.7,0.059,0.124,0.0061,40326.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-07-31",24,24,5514,,0.012,0.001,2291.6,0.059,0.124,0.0064,38556.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-01",24,24,5311,,0.011,0.001,2220.8,0.059,0.131,0.007,37362.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-02",24,24,5492,,0.012,0.001,2290.4,0.059,0.135,0.007,38537.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-03",24,24,5193,,0.011,0.001,2171.2,0.059,0.128,0.007,36533.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-04",13,11.42,2336.1,,0.005,0.001,999.568,0.059,0.08,0.012,16819.258,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-05",10,8.42,1796.12,,0.004,0.001,798.089,0.0591,0.072,0.0145,13428.565,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-06",1,0.37,24.05,,0,0.001,18.759,0.059,0.003,0.016,315.795,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-07",9,8.13,1791.26,,0.004,0.001,769.67,0.059,0.084,0.0222,12949.574,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-08",10,9.25,2115.05,,0.005,0.001,921.725,0.059,0.079,0.0139,15511.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-09",10,9.2,2127.2,,0.005,0.001,916.72,0.059,0.077,0.0143,15424.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-10",11,10.33,2390.05,,0.005,0.001,1035.45,0.059,0.084,0.0125,17424.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-11",11,10.38,2297.88,,0.005,0.001,991.528,0.059,0.081,0.0123,16687.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-12",12,11.83,2879.83,,0.006,0.001,1236.129,0.059,0.091,0.0108,20801.009,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-13",24,24,6250,,0.013,0.001,2614.3,0.059,0.138,0.0063,43988.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-14",24,24,6299,,0.013,0.001,2626.8,0.059,0.139,0.0063,44198.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-15",24,24,6167,,0.013,0.001,2587.2,0.059,0.135,0.0062,43531.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-16",24,24,6523,,0.014,0.001,2730.3,0.059,0.154,0.0067,45941.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-17",24,24,6517,,0.014,0.001,2734.2,0.059,0.161,0.007,46006.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-18",24,24,6338,,0.013,0.001,2654.3,0.059,0.156,0.007,44668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-19",24,24,5916,,0.013,0.001,2489.3,0.059,0.148,0.007,41888.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-20",24,24,4810,,0.01,0.001,2028.6,0.059,0.119,0.007,34137.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-21",24,24,6317,,0.013,0.001,2619.8,0.059,0.155,0.007,44083.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-22",24,24,5991,,0.013,0.001,2488.9,0.059,0.147,0.007,41880,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-23",24,24,5740,,0.012,0.001,2393,0.059,0.141,0.007,40269,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-24",24,24,6433,,0.014,0.001,2678.4,0.059,0.158,0.007,45067.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-25",24,24,5628,,0.012,0.001,2353.9,0.059,0.129,0.0065,39613.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-26",24,24,5335,,0.011,0.001,2242.2,0.059,0.116,0.0061,37728.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-27",24,24,5275,,0.011,0.001,2211.8,0.059,0.115,0.0061,37221.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-28",24,24,5392,,0.011,0.001,2267.4,0.059,0.119,0.0062,38152.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-29",24,24,6628,,0.014,0.001,2765.4,0.059,0.137,0.0058,46531.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-30",14,12.42,2449.82,,0.005,0.001,1068.897,0.0591,0.078,0.0104,17985.678,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-08-31",24,24,4881,,0.011,0.001,2086,0.059,0.106,0.006,35098.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-01",10,8.4,1487.75,,0.003,0.001,659.275,0.059,0.06,0.0137,11092.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-02",24,24,6687,,0.014,0.001,2833.5,0.059,0.145,0.0061,47682.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-03",24,24,5513,,0.012,0.001,2338.7,0.059,0.12,0.0061,39353.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-04",24,24,5959,,0.013,0.001,2497.3,0.059,0.131,0.0063,42021.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-05",24,24,5364,,0.012,0.001,2278.7,0.059,0.118,0.0062,38343.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-06",24,24,5831,,0.012,0.001,2460.4,0.059,0.127,0.0061,41397.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-07",24,24,6276,,0.013,0.001,2639.4,0.059,0.137,0.0062,44413.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-08",24,24,5520,,0.012,0.001,2325.1,0.059,0.122,0.0062,39127.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-09",14,12.44,2359.12,,0.005,0.001,1028.709,0.059,0.074,0.01,17308.674,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-10",11,10.33,1882.44,,0.004,0.001,828.914,0.059,0.064,0.0108,13946.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-11",10,8.82,1550.05,,0.003,0.001,689.203,0.0591,0.058,0.0162,11597.995,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-12",9,8.25,1892.75,,0.004,0.001,828.975,0.059,0.068,0.0132,13947.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-13",10,8.75,1921.45,,0.004,0.001,832.935,0.059,0.068,0.0175,14014.255,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-14",11,10.35,2487.4,,0.005,0.001,1077.95,0.059,0.078,0.0113,18142.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-15",12,11.21,2627.41,,0.006,0.001,1141.901,0.059,0.081,0.0115,19214.043,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-16",13,12.72,3008.02,,0.007,0.001,1303.172,0.059,0.092,0.0102,21925.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-17",13,12.3,3026.5,,0.007,0.001,1302.24,0.059,0.09,0.0102,21909.63,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-18",13,12,2533.2,,0.006,0.001,1094.7,0.0591,0.08,0.0124,18419.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-19",10,9.82,2205.76,,0.005,0.001,962.423,0.059,0.074,0.0111,16194.831,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-20",10,8.5,1823.05,,0.004,0.001,803.84,0.059,0.071,0.0161,13528.17,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-21",11,9.48,2017.71,,0.004,0.001,890.52,0.059,0.072,0.0144,14984.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-22",8,6.66,1248.19,,0.003,0.001,570.215,0.059,0.058,0.0153,9595.373,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-23",16,15.98,3321,,0.007,0.001,1433.836,0.059,0.096,0.0089,24126.026,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-24",22,21.33,5073.8,,0.011,0.001,2159.203,0.059,0.115,0.0067,36331.411,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-25",18,17.97,3652.48,,0.008,0.001,1564.731,0.059,0.101,0.0087,26328.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-26",12,10.4,2179.98,,0.005,0.001,950.262,0.059,0.073,0.0139,15987.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-27",13,12.98,2791.24,,0.006,0.001,1197.332,0.059,0.089,0.0108,20149.938,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-28",19,18.32,4109.26,,0.009,0.001,1749.267,0.059,0.111,0.0087,29436.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-29",24,24,5415,,0.011,0.001,2268.2,0.059,0.118,0.0062,38167.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-09-30",24,24,5866,,0.012,0.001,2416,0.059,0.13,0.0064,40654.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-01",24,24,5479,,0.011,0.001,2261.3,0.059,0.12,0.0063,38049,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-02",24,24,5436,,0.011,0.001,2247.3,0.059,0.119,0.0063,37812.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-03",19,18.17,4034.66,,0.009,0.001,1695.798,0.059,0.106,0.0093,28535.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-04",11,10.25,2425.15,,0.005,0.001,1036.69,0.059,0.079,0.0122,17441.59,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-05",20,19.33,4608.53,,0.01,0.001,1946.958,0.059,0.125,0.0101,32759.517,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-06",24,24,6290,,0.013,0.001,2618,0.059,0.137,0.0062,44054.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-07",24,24,6007,,0.012,0.001,2463.7,0.059,0.131,0.0063,41455.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-08",13,11.88,2153.54,,0.005,0.001,936.755,0.059,0.07,0.0106,15763.539,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-09",13,11.33,2010.7,,0.005,0.001,901.686,0.059,0.075,0.0128,15169.235,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-10",14,12.6,2480.14,,0.005,0.001,1075.02,0.0591,0.078,0.0094,18089.776,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-12",11,10.05,1963,,0.004,0.001,854.065,0.059,0.078,0.0148,14371.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-13",14,13.32,2659.12,,0.006,0.001,1150.041,0.059,0.086,0.011,19352.926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-14",24,24,5514,,0.012,0.001,2280.7,0.059,0.118,0.0062,38378.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-15",24,24,6142,,0.013,0.001,2497.6,0.059,0.129,0.0061,42028.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-16",24,24,5275,,0.011,0.001,2192.1,0.059,0.114,0.0062,36891.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-17",24,24,5274,,0.011,0.001,2190,0.059,0.114,0.0062,36850.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-18",11,9.42,2139.12,,0.005,0.001,911.612,0.059,0.076,0.0126,15339.973,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-19",11,10.33,2483.7,,0.005,0.001,1049.651,0.059,0.08,0.0119,17663.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-20",12,11.33,2596.87,,0.006,0.001,1098.479,0.059,0.085,0.0114,18483.703,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-21",24,24,5902,,0.012,0.001,2456.4,0.059,0.13,0.0063,41328.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-22",24,23.25,5057,,0.011,0.001,2132.435,0.059,0.126,0.0077,35881.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-23",24,24,5472,,0.012,0.001,2280.6,0.059,0.134,0.007,38375.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-24",11,10.17,2330.21,,0.005,0.001,1001.441,0.0591,0.086,0.0187,16850.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-25",10,7.95,1532.54,,0.003,0.001,679.13,0.059,0.074,0.0222,11430.273,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-26",23,21.15,5165.45,,0.011,0.001,2181.515,0.059,0.138,0.0101,36711.005,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-27",24,24,6083,,0.013,0.001,2548.6,0.059,0.14,0.0065,42882.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-28",24,24,5834,,0.012,0.001,2421.1,0.059,0.143,0.007,40740.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-29",24,24,5389,,0.011,0.001,2234.2,0.059,0.126,0.0067,37594.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-30",24,24,5622,,0.012,0.001,2314.5,0.059,0.128,0.0065,38948.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-10-31",12,11.23,2645.02,,0.006,0.001,1118.041,0.059,0.087,0.0124,18812.764,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-01",24,24,5810,,0.012,0.001,2405.8,0.059,0.13,0.0064,40481.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-02",24,24,6470,,0.014,0.001,2678.6,0.059,0.142,0.0063,45072.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-03",24,24,6271,,0.013,0.001,2597.6,0.059,0.139,0.0063,43705.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-04",24,24,6048,,0.013,0.001,2513.1,0.059,0.131,0.0062,42284.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-05",24,24,6396,,0.013,0.001,2649.2,0.059,0.14,0.0063,44580.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-06",24,24,5185,,0.011,0.001,2149.6,0.059,0.113,0.0062,36168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-07",12,11.57,2251.11,,0.005,0.001,969.859,0.059,0.081,0.0124,16317.165,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-08",12,11.07,2449.82,,0.005,0.001,1050.524,0.059,0.085,0.0149,17677.689,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-09",24,24,6241,,0.013,0.001,2614.9,0.059,0.141,0.0064,43999.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-10",19,18.32,4607.9,,0.01,0.001,1941.517,0.059,0.127,0.0096,32676.398,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-11",2,1.12,244.96,,0.001,0.001,104.92,0.059,0.007,0.024,1765.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-15",11,10.03,2094,,0.005,0.001,942.506,0.059,0.105,0.0186,15859.557,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-16",24,24,5293,,0.011,0.001,2258.8,0.059,0.117,0.0062,38011.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-17",24,24,5429,,0.012,0.001,2307.6,0.059,0.122,0.0063,38827.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-18",24,24,5177,,0.011,0.001,2233.7,0.059,0.118,0.0063,37582.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-19",11,10.02,2394.26,,0.005,0.001,1021.702,0.059,0.08,0.015,17192.608,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-20",24,24,6018,,0.013,0.001,2479.8,0.059,0.132,0.0063,41722.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-21",11,10.26,2503.12,,0.005,0.001,1068.637,0.059,0.087,0.0139,17981.953,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-22",12,10.7,2521.5,,0.005,0.001,1064.315,0.059,0.089,0.018,17912.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-23",13,11.42,2525.73,,0.005,0.001,1072.111,0.0591,0.084,0.0118,18040.486,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-24",20,19.22,4611.22,,0.01,0.001,1935.441,0.059,0.122,0.0092,32566.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-25",20,19.39,4398.54,,0.009,0.001,1848.192,0.059,0.117,0.0089,31099.439,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-26",11,9.19,1424.68,,0.003,0.001,653.334,0.059,0.084,0.0267,10994.946,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-27",11,10.23,2323.87,,0.005,0.001,993.101,0.059,0.083,0.0138,16711.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-28",10,9.32,2209.92,,0.005,0.001,939.84,0.059,0.081,0.0142,15813.879,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-29",11,10.28,2536.33,,0.005,0.001,1082.572,0.059,0.087,0.0133,18214.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-11-30",10,9.35,2463.1,,0.005,0.001,1035.23,0.059,0.057,0.0073,17419.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-01",16,14.68,3506.7,,0.008,0.001,1510.478,0.059,0.129,0.0136,25417.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-02",24,24,6128,,0.013,0.001,2540.1,0.059,0.137,0.0064,42743.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-03",24,24,6320,,0.013,0.001,2624.6,0.059,0.142,0.0064,44163.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-04",24,24,6273,,0.013,0.001,2608.3,0.059,0.14,0.0064,43889.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-05",24,24,6108,,0.013,0.001,2527.6,0.059,0.148,0.007,42531.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-06",24,24,5981,,0.012,0.001,2465.9,0.059,0.146,0.007,41492,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-07",24,24,6086,,0.013,0.001,2522.1,0.059,0.15,0.007,42440.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-08",24,24,5957,,0.012,0.001,2471.1,0.059,0.145,0.007,41579.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-09",24,24,5979,,0.012,0.001,2474.6,0.059,0.146,0.007,41639.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-10",24,24,6302,,0.013,0.001,2607.4,0.059,0.154,0.007,43877.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-11",24,24,6307,,0.013,0.001,2609.2,0.059,0.155,0.007,43903.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-12",24,24,6172,,0.013,0.001,2571.6,0.059,0.151,0.007,43272.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-13",24,24,6567,,0.014,0.001,2713.7,0.059,0.14,0.0061,45661,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-14",24,24,6207,,0.013,0.001,2566.2,0.059,0.138,0.0064,43179.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-15",24,24,6228,,0.013,0.001,2579.8,0.059,0.141,0.0065,43409.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-16",24,24,6586,,0.014,0.001,2706.2,0.059,0.143,0.0063,45535.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-17",24,24,5761,,0.012,0.001,2381.5,0.059,0.121,0.006,40076.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-18",24,24,5509,,0.012,0.001,2293.2,0.059,0.131,0.0068,38588.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-19",20,18.42,4502.42,,0.01,0.001,1899.236,0.059,0.13,0.0098,31957.297,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-20",12,10.37,2437,,0.005,0.001,1051.376,0.0591,0.086,0.0123,17689.346,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-21",21,20.1,5025.94,,0.011,0.001,2113.772,0.059,0.132,0.01,35567.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-22",20,19.09,4497.05,,0.01,0.001,1918.17,0.059,0.124,0.0104,32275.879,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-23",24,24,6039,,0.013,0.001,2518.4,0.059,0.138,0.0065,42377.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-24",24,24,6512,,0.014,0.001,2689.4,0.059,0.146,0.0065,45253,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-25",19,17.37,4306.69,,0.009,0.001,1808.983,0.059,0.12,0.0093,30441.123,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-26",11,10.33,2269.5,,0.005,0.001,966.469,0.059,0.081,0.0127,16263.265,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-27",24,24,6159,,0.013,0.001,2544.9,0.059,0.137,0.0064,42823.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-28",24,24,6474,,0.014,0.001,2689.5,0.059,0.157,0.007,45259.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-29",20,19.48,5066.68,,0.011,0.001,2113.564,0.059,0.141,0.0096,35563.788,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-30",24,24,5495,,0.011,0.001,2276.2,0.059,0.132,0.0069,38301.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Metcalf Energy Center",55393,"2",,"2020-12-31",12,10.39,2481.05,,0.005,0.001,1060.4,0.059,0.085,0.0122,17844.614,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-01",24,24,5198,,0.01,0.001,2005.1,0.059,0.064,0.0038,33736.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-02",24,24,5573,,0.01,0.001,2040.2,0.059,0.076,0.0044,34332.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-03",24,24,5900,,0.011,0.001,2107.2,0.059,0.082,0.0046,35458.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-04",24,24,5564,,0.01,0.001,2043.6,0.059,0.078,0.0045,34383.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-05",24,24,5821,,0.011,0.001,2080.3,0.059,0.099,0.0056,35002.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-06",24,24,5872,,0.01,0.001,2072.4,0.059,0.091,0.0052,34869.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-07",24,24,5778,,0.01,0.001,2051.8,0.059,0.078,0.0045,34527.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-08",24,24,5604,,0.01,0.001,2070.6,0.059,0.078,0.0045,34844.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-09",24,24,5780,,0.011,0.001,2100.4,0.059,0.09,0.005,35346.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-10",24,24,5872,,0.011,0.001,2083.3,0.059,0.091,0.0052,35053.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-11",24,24,5268,,0.01,0.001,2003,0.059,0.065,0.0038,33704.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-12",24,24,5400,,0.01,0.001,2002.9,0.059,0.061,0.0036,33707.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-13",24,24,5528,,0.01,0.001,2043.7,0.059,0.066,0.0038,34392.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-14",24,24,5551,,0.01,0.001,2032.6,0.059,0.072,0.0042,34203.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-15",24,24,5723,,0.011,0.001,2089.4,0.059,0.081,0.0046,35160.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-16",24,24,5629,,0.01,0.001,2043.8,0.059,0.077,0.0045,34388.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-17",24,24,5626,,0.01,0.001,2033.9,0.059,0.081,0.0047,34226,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-18",23,22.3,5176.1,,0.01,0.001,1884.41,0.059,0.073,0.0046,31711.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-19",20,19.85,4679.95,,0.008,0.001,1660.33,0.0591,0.158,0.0185,27936,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-20",24,24,5986,,0.011,0.001,2085.6,0.059,0.061,0.0035,35092.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-21",24,24,5392,,0.011,0.001,2115.5,0.059,0.046,0.0026,35597.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-22",24,24,5396,,0.011,0.001,2164,0.059,0.051,0.0028,36417.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-23",24,24,5673,,0.011,0.001,2200.5,0.059,0.086,0.0046,37028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-24",24,24,5477,,0.011,0.001,2184,0.059,0.086,0.0047,36748.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-25",24,24,5765,,0.011,0.001,2253.7,0.059,0.098,0.0051,37920,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-26",24,24,5588,,0.011,0.001,2183.7,0.059,0.084,0.0045,36743.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-27",24,24,5358,,0.011,0.001,2160.3,0.059,0.081,0.0045,36354.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-28",24,24,5464,,0.011,0.001,2177.5,0.059,0.092,0.005,36644.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-29",24,24,5807,,0.011,0.001,2243.1,0.059,0.106,0.0056,37748.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-30",24,24,5676,,0.011,0.001,2206.8,0.059,0.101,0.0054,37134.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-01-31",24,24,5498,,0.011,0.001,2191.2,0.059,0.094,0.005,36869.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-01",24,24,5687,,0.011,0.001,2227.8,0.059,0.098,0.0052,37486.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-02",24,24,5670,,0.011,0.001,2229.2,0.059,0.104,0.0055,37515.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-03",24,24,5824,,0.011,0.001,2232.6,0.059,0.092,0.0049,37567.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-04",24,24,5690,,0.011,0.001,2173.4,0.059,0.099,0.0054,36568.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-05",24,24,5655,,0.011,0.001,2189,0.059,0.086,0.0047,36836,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-06",24,24,5452,,0.011,0.001,2175.8,0.059,0.08,0.0043,36609.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-07",10,9.3,2042,,0.004,0.001,830.88,0.059,0.034,0.007,13980.97,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-13",12,10.1,57.79,,0.005,0.0009,1042.292,0.059,1.28,0.1454,17535.717,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-14",12,10.5,1727.1,,0.005,0.0009,1086.732,0.0591,0.583,0.0756,18282.562,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-15",24,24,5554,,0.013,0.001,2503.2,0.059,0.126,0.006,42110.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-16",24,24,5508,,0.013,0.001,2503.2,0.059,0.15,0.0071,42110.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-17",24,24,5679,,0.013,0.001,2519.7,0.059,0.136,0.0064,42384.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-18",20,18.86,4004.1,,0.01,0.001,1981.944,0.0591,0.4,0.0306,33338.035,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-19",24,24,5548,,0.013,0.001,2529.6,0.059,0.14,0.0066,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-20",24,24,5730,,0.013,0.001,2601.3,0.059,0.141,0.0065,43761.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-21",24,24,5953,,0.014,0.001,2690.3,0.059,0.13,0.0057,45267.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-22",24,24,5859,,0.013,0.001,2641.6,0.059,0.124,0.0055,44444.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-23",24,24,5886,,0.013,0.001,2585.2,0.059,0.122,0.0056,43489.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-24",24,24,6147,,0.013,0.001,2552.4,0.059,0.122,0.0057,42939.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-25",24,24,5828,,0.013,0.001,2604,0.059,0.121,0.0055,43806.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-26",24,24,5977,,0.014,0.001,2734.8,0.059,0.133,0.0058,46016.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-27",24,24,5782,,0.013,0.001,2613.7,0.059,0.145,0.0065,43971,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-28",24,24,5918,,0.013,0.001,2662.3,0.059,0.134,0.006,44794.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-29",24,24,5721,,0.013,0.001,2624.1,0.059,0.125,0.0057,44146.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-30",24,24,5653,,0.013,0.001,2603.4,0.059,0.123,0.0056,43795.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-03-31",24,24,5489,,0.013,0.001,2542.4,0.059,0.126,0.0059,42764.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-01",24,24,5676,,0.013,0.001,2634.4,0.059,0.128,0.0058,44321.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-02",24,24,5590,,0.013,0.001,2529.6,0.059,0.137,0.0064,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-03",24,24,5523,,0.013,0.001,2529.6,0.059,0.142,0.0067,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-04",24,24,5681,,0.013,0.001,2529.6,0.059,0.151,0.0071,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-05",24,24,6142,,0.013,0.001,2529.6,0.059,0.161,0.0076,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-06",24,24,6030,,0.013,0.001,2529.6,0.059,0.154,0.0073,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-07",24,24,5891,,0.013,0.001,2529.6,0.059,0.156,0.0073,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-08",24,24,6100,,0.013,0.001,2529.6,0.059,0.17,0.008,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-09",24,24,5858,,0.013,0.001,2529.6,0.059,0.17,0.008,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-10",21,20.05,4539.34,,0.011,0.001,2111.038,0.059,0.335,0.0262,35509.133,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-11",24,24,5860,,0.013,0.001,2529.6,0.059,0.144,0.0068,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-12",24,24,5886,,0.013,0.001,2529.6,0.059,0.144,0.0068,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-13",24,24,5884,,0.013,0.001,2529.6,0.059,0.16,0.0075,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-14",24,24,5890,,0.013,0.001,2529.6,0.059,0.168,0.0079,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-15",24,24,5890,,0.013,0.001,2529.6,0.059,0.149,0.007,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-16",24,24,5895,,0.013,0.001,2529.6,0.059,0.163,0.0077,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-17",24,24,5906,,0.013,0.001,2529.6,0.059,0.158,0.0074,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-18",20,19.25,4739.75,,0.01,0.001,2028.975,0.059,0.136,0.0079,34129.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-24",16,15.48,3402.08,,0.008,0.001,1658.976,0.059,0.341,0.0299,27905.856,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-25",24,24,5748,,0.013,0.001,2572.8,0.059,0.123,0.0057,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-26",24,24,5513,,0.013,0.001,2572.8,0.059,0.12,0.0055,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-27",24,24,5330,,0.013,0.001,2572.8,0.059,0.121,0.0056,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-28",24,24,5676,,0.013,0.001,2572.8,0.059,0.13,0.006,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-29",24,24,5641,,0.013,0.001,2572.8,0.059,0.129,0.006,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-04-30",24,24,5199,,0.013,0.001,2572.8,0.059,0.124,0.0058,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-01",24,24,5457,,0.013,0.001,2572.8,0.059,0.123,0.0057,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-02",24,24,5341,,0.013,0.001,2572.8,0.059,0.129,0.006,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-03",24,24,5359,,0.013,0.001,2572.8,0.059,0.119,0.0055,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-04",24,24,5676,,0.013,0.001,2572.8,0.059,0.135,0.0063,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-05",24,23.17,5372.25,,0.013,0.001,2491.639,0.059,0.169,0.0145,41914.084,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-06",16,15.97,3665.28,,0.009,0.001,1711.596,0.059,0.389,0.0274,28791.963,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-07",24,24,5565,,0.013,0.001,2572.8,0.059,0.112,0.0052,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-08",24,24,5632,,0.013,0.001,2572.8,0.059,0.106,0.0049,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-09",24,24,5754,,0.014,0.001,2692.1,0.059,0.116,0.0051,45286.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-10",24,24,5472,,0.013,0.001,2609,0.059,0.115,0.0053,43888.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-11",24,24,5665,,0.014,0.001,2675.4,0.059,0.128,0.0056,45006.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-12",24,24,5723,,0.013,0.001,2663.9,0.059,0.129,0.0057,44816.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-13",24,24,5522,,0.014,0.001,2684.4,0.059,0.126,0.0055,45157.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-14",21,19.83,4409.25,,0.011,0.001,2162.751,0.059,0.216,0.0137,36381.231,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-15",24,24,5426,,0.013,0.001,2605.4,0.059,0.12,0.0055,43829.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-16",24,24,5768,,0.014,0.001,2743.5,0.059,0.122,0.0053,46155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-17",24,24,5568,,0.014,0.001,2680.4,0.059,0.116,0.0051,45091.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-18",24,24,5323,,0.013,0.001,2572.8,0.059,0.108,0.005,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-19",24,24,5181,,0.013,0.001,2523.8,0.059,0.103,0.0048,42466.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-20",24,24,5244,,0.013,0.001,2488.8,0.059,0.097,0.0046,41887.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-21",24,24,5432,,0.013,0.001,2559.3,0.059,0.112,0.0052,43069.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-22",24,24,5450,,0.013,0.001,2561.5,0.059,0.113,0.0052,43110.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-23",24,24,5330,,0.013,0.001,2513.2,0.059,0.102,0.0048,42296.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-24",24,24,5328,,0.013,0.001,2497.4,0.059,0.095,0.0045,42031.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-25",24,24,5667,,0.013,0.001,2640.8,0.059,0.109,0.0049,44443.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-26",24,24,5888,,0.013,0.001,2668.5,0.059,0.112,0.005,44906.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-27",24,24,5815,,0.014,0.001,2700.5,0.059,0.108,0.0048,45441.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-28",24,24,5590,,0.013,0.001,2601.4,0.059,0.114,0.0052,43778.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-29",24,24,5611,,0.013,0.001,2612.3,0.059,0.122,0.0055,43958.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-30",24,24,5411,,0.013,0.001,2537.5,0.059,0.137,0.0064,42706.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-05-31",24,24,5371,,0.013,0.001,2526.9,0.059,0.118,0.0055,42524.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-01",24,24,5946,,0.013,0.001,2653.6,0.059,0.134,0.006,44651,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-02",24,24,5929,,0.014,0.001,2699.9,0.059,0.126,0.0055,45432.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-03",24,24,6193,,0.014,0.001,2866.1,0.059,0.131,0.0054,48229.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-04",24,24,5898,,0.014,0.001,2749.8,0.059,0.125,0.0054,46269,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-05",24,24,5670,,0.013,0.001,2608.8,0.059,0.112,0.0051,43905.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-06",24,24,5313,,0.013,0.001,2514.9,0.059,0.118,0.0056,42326.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-07",24,24,5383,,0.013,0.001,2546.5,0.059,0.119,0.0055,42856.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-08",24,24,5661,,0.013,0.001,2594.9,0.059,0.119,0.0054,43670.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-09",24,24,5798,,0.013,0.001,2663.2,0.059,0.115,0.0051,44815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-10",24,24,5931,,0.014,0.001,2700.2,0.059,0.118,0.0052,45438.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-11",24,24,5983,,0.014,0.001,2731.2,0.059,0.119,0.0052,45956.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-12",24,24,5778,,0.013,0.001,2612.8,0.059,0.108,0.0049,43970.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-13",24,24,5484,,0.013,0.001,2548.5,0.059,0.123,0.0057,42888.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-14",24,24,5436,,0.013,0.001,2557.8,0.059,0.126,0.0059,43046.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-15",24,24,5681,,0.013,0.001,2609.6,0.059,0.128,0.0058,43914.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-16",24,24,5714,,0.013,0.001,2649.9,0.059,0.127,0.0057,44594.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-17",24,24,5398,,0.013,0.001,2561.2,0.059,0.128,0.006,43102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-18",24,24,5666,,0.013,0.001,2617.1,0.059,0.123,0.0056,44043.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-19",24,24,5932,,0.013,0.001,2663.7,0.059,0.122,0.0054,44830.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-20",24,24,5755,,0.013,0.001,2620.3,0.059,0.12,0.0054,44094.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-21",24,24,5541,,0.013,0.001,2596.5,0.059,0.119,0.0055,43693.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-22",24,24,6136,,0.014,0.001,2807.8,0.059,0.129,0.0055,47250.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-23",24,24,6138,,0.014,0.001,2760.1,0.059,0.132,0.0057,46443.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-24",24,24,6097,,0.013,0.001,2636.8,0.059,0.121,0.0054,44368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-25",24,24,5964,,0.013,0.001,2611.1,0.059,0.118,0.0054,43934.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-26",24,24,6137,,0.014,0.001,2682.4,0.059,0.116,0.0051,45136.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-27",24,24,6071,,0.014,0.001,2688.7,0.059,0.111,0.0049,45242.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-28",24,24,5717,,0.013,0.001,2525,0.059,0.115,0.0054,42479.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-29",24,24,5548,,0.012,0.001,2426.1,0.059,0.117,0.0057,40812.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-06-30",24,24,5452,,0.012,0.001,2424.5,0.059,0.104,0.0051,40783.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-01",24,24,5699,,0.012,0.001,2465.9,0.059,0.107,0.0051,41488.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-02",24,24,5558,,0.012,0.001,2453.1,0.059,0.106,0.0051,41268.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-03",24,24,5938,,0.013,0.001,2563.1,0.059,0.109,0.005,43121.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-04",24,24,6029,,0.013,0.001,2632.3,0.059,0.118,0.0053,44292.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-05",24,24,5994,,0.013,0.001,2611.4,0.059,0.143,0.0065,43941.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-06",24,24,5798,,0.013,0.001,2503.1,0.059,0.125,0.006,42114.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-07",24,24,5754,,0.013,0.001,2514.1,0.059,0.115,0.0054,42299.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-08",24,24,5735,,0.013,0.001,2486.3,0.059,0.119,0.0057,41825.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-09",24,24,5799,,0.013,0.001,2534.1,0.059,0.111,0.0052,42635.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-10",24,24,5836,,0.013,0.001,2549.4,0.059,0.108,0.005,42890.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-11",24,24,6044,,0.013,0.001,2622.7,0.059,0.112,0.0051,44128.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-12",24,24,5936,,0.013,0.001,2611.1,0.059,0.115,0.0052,43934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-13",24,24,5898,,0.013,0.001,2566.3,0.059,0.113,0.0052,43177.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-14",24,24,5737,,0.012,0.001,2476.2,0.059,0.112,0.0054,41655.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-15",24,24,5532,,0.012,0.001,2432.7,0.059,0.11,0.0054,40923.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-16",24,24,5404,,0.012,0.001,2416.6,0.059,0.109,0.0053,40650.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-17",24,24,5692,,0.013,0.001,2520.9,0.059,0.118,0.0056,42410.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-18",24,24,5957,,0.013,0.001,2627,0.059,0.108,0.0049,44204.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-19",24,24,5611,,0.013,0.001,2485,0.059,0.098,0.0047,41806.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-20",24,24,5609,,0.012,0.001,2470.8,0.059,0.101,0.0048,41565.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-21",24,24,6047,,0.013,0.001,2635,0.059,0.115,0.0052,44336.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-22",24,24,5755,,0.013,0.001,2555.1,0.059,0.102,0.0048,42993.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-23",24,24,5694,,0.013,0.001,2534.7,0.059,0.123,0.0058,42657.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-24",24,24,5807,,0.013,0.001,2590.4,0.059,0.12,0.0055,43603.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-25",24,24,6099,,0.014,0.001,2693.2,0.059,0.118,0.0052,45329.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-26",24,24,6107,,0.014,0.001,2704,0.059,0.116,0.0051,45516.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-27",24,24,6103,,0.013,0.001,2642.6,0.059,0.125,0.0056,44474.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-28",24,24,6109,,0.013,0.001,2660.7,0.059,0.12,0.0054,44778.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-29",24,24,6069,,0.013,0.001,2649.8,0.059,0.113,0.0051,44596.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-30",24,24,5995,,0.013,0.001,2633.7,0.059,0.114,0.0051,44327.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-07-31",24,24,6058,,0.013,0.001,2667.5,0.059,0.115,0.0051,44896.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-01",24,24,5659,,0.013,0.001,2515.1,0.059,0.104,0.0049,42331.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-02",24,24,5836,,0.013,0.001,2594.6,0.059,0.106,0.0048,43670,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-03",24,24,5702,,0.013,0.001,2526.7,0.059,0.111,0.0052,42527.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-04",24,24,5673,,0.013,0.001,2501.9,0.059,0.126,0.006,42108.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-05",24,24,5548,,0.013,0.001,2478.5,0.059,0.122,0.0058,41719.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-06",24,24,5498,,0.012,0.001,2448.7,0.059,0.106,0.0051,41216.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-07",24,24,5710,,0.013,0.001,2572.3,0.059,0.103,0.0048,43295.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-08",24,24,5777,,0.013,0.001,2590,0.059,0.108,0.005,43592.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-09",24,24,5881,,0.013,0.001,2620.8,0.059,0.109,0.0049,44112.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-10",24,24,5992,,0.014,0.001,2675,0.059,0.108,0.0048,45022,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-11",24,24,5765,,0.013,0.001,2580.9,0.059,0.105,0.0048,43438.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-12",24,24,5930,,0.013,0.001,2637.7,0.059,0.106,0.0048,44392.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-13",24,24,6252,,0.014,0.001,2730,0.059,0.115,0.005,45949.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-14",24,24,6092,,0.014,0.001,2716.5,0.059,0.113,0.0049,45726.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-15",24,24,6045,,0.014,0.001,2694.8,0.059,0.112,0.0049,45358.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-16",24,24,5635,,0.013,0.001,2564.7,0.059,0.105,0.0048,43165.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-17",24,24,5700,,0.013,0.001,2573,0.059,0.107,0.0049,43307.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-18",24,24,5599,,0.013,0.001,2549.2,0.059,0.108,0.005,42897.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-19",24,24,5509,,0.013,0.001,2532.5,0.059,0.103,0.0048,42612.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-20",24,24,5089,,0.012,0.001,2400,0.059,0.094,0.0047,40382.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-21",24,24,5312,,0.012,0.001,2415.8,0.059,0.104,0.0051,40650,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-22",24,24,6000,,0.014,0.001,2712.1,0.059,0.126,0.0055,45629.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-23",24,24,6034,,0.014,0.001,2736.7,0.059,0.126,0.0055,46043.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-24",24,24,6170,,0.014,0.001,2792.2,0.059,0.129,0.0055,46978.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-25",24,24,5866,,0.013,0.001,2673.5,0.059,0.115,0.0051,44985.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-26",24,24,5317,,0.012,0.001,2453.8,0.059,0.091,0.0044,41285.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-27",24,24,5200,,0.012,0.001,2421.3,0.059,0.098,0.0048,40742.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-28",24,24,5680,,0.013,0.001,2558.5,0.059,0.102,0.0047,43045.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-29",24,24,5584,,0.013,0.001,2550.4,0.059,0.101,0.0047,42915,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-30",24,24,5330,,0.012,0.001,2458.9,0.059,0.099,0.0048,41375.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-08-31",24,24,5492,,0.013,0.001,2510.8,0.059,0.102,0.0048,42247.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-01",24,24,5876,,0.013,0.001,2662,0.059,0.118,0.0053,44792.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-02",24,24,5723,,0.013,0.001,2609.4,0.059,0.112,0.0051,43905.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-03",24,24,6124,,0.014,0.001,2716.8,0.059,0.116,0.0051,45709.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-04",24,24,6131,,0.014,0.001,2735.4,0.059,0.116,0.005,46021.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-05",24,24,5289,,0.012,0.001,2436.8,0.059,0.089,0.0043,41002,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-06",24,24,5575,,0.013,0.001,2593.6,0.059,0.107,0.0049,43637.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-07",24,24,5541,,0.013,0.001,2587.9,0.059,0.102,0.0047,43545.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-08",24,24,5258,,0.012,0.001,2455.8,0.059,0.104,0.005,41321,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-09",24,24,5532,,0.013,0.001,2540.8,0.059,0.124,0.0058,42754.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-10",24,24,6084,,0.014,0.001,2725.7,0.059,0.149,0.0065,45863.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-11",24,24,6373,,0.014,0.001,2823.9,0.059,0.15,0.0063,47509,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-12",24,24,6227,,0.014,0.001,2758.7,0.059,0.127,0.0055,46412.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-13",24,24,6192,,0.014,0.001,2757.4,0.059,0.115,0.0049,46389.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-14",24,24,6403,,0.014,0.001,2822.9,0.059,0.119,0.005,47491.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-15",24,24,6410,,0.014,0.001,2833.8,0.059,0.119,0.005,47676.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-16",24,24,6290,,0.014,0.001,2784.7,0.059,0.116,0.005,46850.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-17",24,24,6373,,0.014,0.001,2831.7,0.059,0.123,0.0052,47639.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-18",24,24,6255,,0.014,0.001,2781.5,0.059,0.121,0.0052,46797.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-19",24,24,6197,,0.014,0.001,2751.8,0.059,0.113,0.0049,46296.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-20",24,24,6150,,0.014,0.001,2763.6,0.059,0.106,0.0045,46495.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-21",24,24,6370,,0.014,0.001,2807.3,0.059,0.108,0.0045,47229.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-22",24,24,6326,,0.015,0.001,2911.7,0.059,0.132,0.0054,48985.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-23",24,24,6368,,0.015,0.001,3027,0.059,0.129,0.0051,50923.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-24",24,24,5819,,0.014,0.001,2802.1,0.059,0.107,0.0045,47148.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-25",24,24,5947,,0.014,0.001,2864,0.059,0.113,0.0047,48188.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-26",24,24,5600,,0.014,0.001,2733.1,0.059,0.112,0.0048,45991.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-27",24,24,5604,,0.014,0.001,2746.3,0.059,0.119,0.0051,46213.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-28",24,24,5735,,0.014,0.001,2787.1,0.059,0.118,0.005,46898.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-29",24,24,6017,,0.015,0.001,2922.2,0.059,0.128,0.0052,49167.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-09-30",24,24,6230,,0.015,0.001,2990.3,0.059,0.134,0.0053,50308.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-01",24,24,6240,,0.015,0.001,2978.4,0.059,0.13,0.0052,50107.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-02",24,24,6230,,0.015,0.001,2990,0.059,0.123,0.0049,50305.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-03",24,24,6209,,0.015,0.001,2984.2,0.059,0.121,0.0048,50206.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-04",24,24,6167,,0.015,0.001,2960.8,0.059,0.12,0.0048,49813.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-05",24,24,6398,,0.015,0.001,3038.4,0.059,0.128,0.005,51115.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-06",24,24,6475,,0.015,0.001,3038.4,0.059,0.122,0.0048,51115.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-07",24,24,6125,,0.014,0.001,2825.6,0.059,0.153,0.0065,47544.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-08",24,24,6204,,0.015,0.001,2965.3,0.059,0.146,0.0058,49889.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-09",24,24,6209,,0.015,0.001,2924.6,0.059,0.144,0.0058,49205.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-10",24,24,5984,,0.014,0.001,2857,0.059,0.121,0.005,48069.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-11",24,24,5997,,0.014,0.001,2864.6,0.059,0.122,0.005,48196.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-12",24,24,6332,,0.015,0.001,2994.3,0.059,0.13,0.0052,50376.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-13",24,24,6439,,0.015,0.001,3038.4,0.059,0.132,0.0052,51115.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-14",24,24,6073,,0.015,0.001,2915.1,0.059,0.119,0.0048,49046,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-15",24,24,6165,,0.015,0.001,2940.8,0.059,0.122,0.0049,49478.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-16",24,24,5993,,0.015,0.001,2895.4,0.059,0.116,0.0048,48717,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-17",24,24,5880,,0.014,0.001,2833.5,0.059,0.11,0.0046,47679.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-18",24,24,6253,,0.015,0.001,2975.2,0.059,0.121,0.0048,50054.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-19",24,24,6379,,0.015,0.001,3005.4,0.059,0.132,0.0052,50562.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-20",24,24,6343,,0.015,0.001,2942,0.059,0.129,0.0052,49498.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-21",24,24,6229,,0.015,0.001,2874.7,0.059,0.115,0.0048,48369.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-22",24,24,6098,,0.015,0.001,2886.1,0.059,0.119,0.0049,48559.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-23",24,24,6104,,0.014,0.001,2793.5,0.059,0.117,0.005,47003.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-24",24,24,6310,,0.015,0.001,2903.5,0.059,0.121,0.005,48855,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-25",24,24,6100,,0.014,0.001,2868.9,0.059,0.116,0.0048,48273.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-26",24,24,6142,,0.014,0.001,2848.2,0.059,0.121,0.005,47925,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-27",24,24,6087,,0.014,0.001,2818.4,0.059,0.117,0.0049,47423.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-28",24,24,5835,,0.014,0.001,2723,0.059,0.109,0.0048,45822.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-29",24,24,5883,,0.013,0.001,2669.7,0.059,0.117,0.0052,44926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-30",24,24,6040,,0.014,0.001,2732.6,0.059,0.115,0.005,45978.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-10-31",24,24,5951,,0.014,0.001,2739.4,0.059,0.109,0.0047,46097.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-01",24,24,6065,,0.014,0.001,2816.5,0.059,0.115,0.0048,47389.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-02",10,9.32,2400.52,,0.006,0.001,1130.104,0.059,0.052,0.0061,19014.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-12",9,8.12,1523.12,,0.004,0.001,846.164,0.059,0.379,0.0493,14241.792,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-13",24,24,5581,,0.013,0.001,2500.8,0.059,0.086,0.0041,42091.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-14",24,24,5579,,0.013,0.001,2500.8,0.059,0.102,0.0048,42091.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-15",24,24,5575,,0.013,0.001,2500.8,0.059,0.103,0.0049,42091.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-16",24,24,5587,,0.013,0.001,2500.8,0.059,0.096,0.0046,42091.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-17",24,24,5605,,0.012,0.001,2400,0.059,0.117,0.0058,40381.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-18",24,24,5585,,0.012,0.001,2328,0.059,0.119,0.0061,39160.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-19",24,24,5771,,0.012,0.001,2388.4,0.059,0.121,0.006,40178.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-20",24,24,6124,,0.012,0.001,2424.2,0.059,0.111,0.0054,40783.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-21",24,24,6118,,0.013,0.001,2535.2,0.059,0.117,0.0055,42655.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-22",24,24,6029,,0.013,0.001,2551.7,0.059,0.116,0.0053,42933.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-23",24,24,6120,,0.013,0.001,2479.3,0.059,0.119,0.0057,41715.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-24",24,24,6103,,0.013,0.001,2524.8,0.059,0.116,0.0054,42480,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-25",24,24,5935,,0.012,0.001,2474.8,0.059,0.102,0.0048,41639.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-26",24,24,5936,,0.013,0.001,2498.5,0.059,0.095,0.0045,42035.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-27",24,24,5709,,0.012,0.001,2369.4,0.059,0.087,0.0043,39859.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-28",24,24,6009,,0.013,0.001,2487.1,0.059,0.097,0.0046,41842.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-29",24,24,6062,,0.013,0.001,2513.2,0.059,0.097,0.0045,42282.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-11-30",24,24,6114,,0.013,0.001,2534,0.059,0.099,0.0046,42636.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-01",24,24,6190,,0.013,0.001,2585.9,0.059,0.095,0.0043,43511.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-02",24,24,5945,,0.013,0.001,2493.3,0.059,0.083,0.0039,41947.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-03",24,24,6034,,0.013,0.001,2507.7,0.059,0.096,0.0045,42194.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-04",24,24,6071,,0.013,0.001,2495.7,0.059,0.094,0.0044,41987.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-05",24,24,5921,,0.012,0.001,2475.3,0.059,0.09,0.0043,41642.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-06",24,24,5817,,0.012,0.001,2419.1,0.059,0.088,0.0043,40700,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-07",24,24,6060,,0.013,0.001,2488.9,0.059,0.097,0.0046,41874.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-08",24,24,5965,,0.012,0.001,2475.1,0.059,0.09,0.0043,41641.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-09",24,24,5882,,0.013,0.001,2483.1,0.059,0.085,0.004,41774.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-10",24,24,6111,,0.013,0.001,2561.1,0.059,0.098,0.0045,43093.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-11",24,24,6254,,0.013,0.001,2563.1,0.059,0.101,0.0046,43124.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-12",24,24,6137,,0.013,0.001,2528.4,0.059,0.091,0.0043,42538.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-13",24,24,6203,,0.013,0.001,2558.6,0.059,0.093,0.0043,43051.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-14",24,24,5902,,0.012,0.001,2466.2,0.059,0.078,0.0037,41490.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-15",24,24,5804,,0.012,0.001,2369.6,0.059,0.084,0.0042,39862.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-16",24,24,6280,,0.013,0.001,2527.4,0.059,0.091,0.0043,42522.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-17",24,24,5412,,0.012,0.001,2339.5,0.059,0.073,0.0037,39356.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-18",24,24,5663,,0.012,0.001,2412.4,0.059,0.087,0.0043,40583.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-19",24,24,5702,,0.012,0.001,2423.3,0.059,0.08,0.0039,40770.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-20",24,24,5849,,0.012,0.001,2448.1,0.059,0.082,0.004,41188.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-21",24,24,6056,,0.012,0.001,2412,0.059,0.081,0.004,40577.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-22",24,24,5934,,0.012,0.001,2418.2,0.059,0.081,0.004,40682.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-23",24,24,6026,,0.013,0.001,2498.8,0.059,0.089,0.0042,42040.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-24",24,24,6163,,0.013,0.001,2512.7,0.059,0.093,0.0044,42273.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-25",24,24,5735,,0.012,0.001,2368.2,0.059,0.077,0.0038,39839.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-26",24,24,5533,,0.012,0.001,2328,0.059,0.069,0.0035,39160.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-27",24,24,5997,,0.013,0.001,2506.1,0.059,0.085,0.004,42164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-28",24,24,6290,,0.013,0.001,2545.2,0.059,0.088,0.0041,42819.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-29",24,24,6035,,0.012,0.001,2454.4,0.059,0.081,0.0039,41288.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-30",24,24,5752,,0.012,0.001,2394.4,0.059,0.07,0.0035,40275,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-1",,"2020-12-31",24,24,5952,,0.013,0.001,2484.3,0.059,0.08,0.0038,41792.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-01",24,24,5182,,0.01,0.001,2008.8,0.059,0.062,0.0037,33803.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-02",24,24,5559,,0.01,0.001,2045.7,0.059,0.083,0.0048,34419.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-03",24,24,5883,,0.011,0.001,2107.9,0.059,0.108,0.006,35470.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-04",24,24,5550,,0.01,0.001,2047,0.059,0.072,0.0042,34446.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-05",24,24,5797,,0.011,0.001,2082.1,0.059,0.107,0.006,35039.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-06",24,24,5828,,0.01,0.001,2069.6,0.059,0.102,0.0058,34822.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-07",24,24,5748,,0.01,0.001,2052.5,0.059,0.091,0.0053,34542.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-08",24,24,5602,,0.01,0.001,2075,0.059,0.08,0.0045,34914,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-09",24,24,5771,,0.011,0.001,2104.8,0.059,0.09,0.005,35420.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-10",24,24,5858,,0.011,0.001,2085.5,0.059,0.102,0.0058,35092.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-11",24,24,5257,,0.01,0.001,2006.6,0.059,0.069,0.0041,33770,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-12",24,24,5373,,0.01,0.001,2006.7,0.059,0.084,0.005,33769.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-13",24,24,5519,,0.01,0.001,2048.2,0.059,0.093,0.0053,34467,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-14",24,24,5541,,0.01,0.001,2037.1,0.059,0.091,0.0053,34274.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-15",24,24,5698,,0.011,0.001,2090,0.059,0.101,0.0057,35169.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-16",24,24,5618,,0.01,0.001,2048.8,0.059,0.071,0.0041,34475.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-17",24,24,5616,,0.01,0.001,2037.4,0.059,0.083,0.0048,34284.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-18",23,22.3,5146.7,,0.01,0.001,1886.63,0.059,0.072,0.0046,31743.97,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-19",11,8.66,1440.22,,0.003,0.001,604.008,0.0592,0.158,0.0741,10162.964,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-20",24,24,6065,,0.011,0.001,2112.7,0.059,0.113,0.0063,35548.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-21",24,24,5413,,0.011,0.001,2118.5,0.059,0.068,0.0038,35647.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-22",24,24,5409,,0.011,0.001,2169.1,0.059,0.112,0.0061,36502.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-23",24,24,5699,,0.011,0.001,2205,0.059,0.107,0.0057,37105.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-24",24,24,5500,,0.011,0.001,2192.1,0.059,0.093,0.005,36882.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-25",24,24,5781,,0.011,0.001,2258.5,0.059,0.105,0.0054,38004.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-26",24,24,5595,,0.011,0.001,2187.6,0.059,0.081,0.0044,36811.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-27",24,24,5357,,0.011,0.001,2164.7,0.059,0.069,0.0038,36428.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-28",24,24,5468,,0.011,0.001,2182.5,0.059,0.084,0.0045,36727.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-29",24,24,5818,,0.011,0.001,2245.7,0.059,0.105,0.0055,37791.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-30",24,24,5708,,0.011,0.001,2213.2,0.059,0.096,0.0051,37244.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-01-31",24,24,5518,,0.011,0.001,2198.6,0.059,0.081,0.0043,36993.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-01",24,24,5708,,0.011,0.001,2232.6,0.059,0.087,0.0046,37564.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-02",24,24,5691,,0.011,0.001,2231.5,0.059,0.093,0.0049,37546.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-03",24,24,5833,,0.011,0.001,2229.6,0.059,0.119,0.0063,37515.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-04",24,24,5700,,0.011,0.001,2176.2,0.059,0.104,0.0056,36617,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-05",24,24,5684,,0.011,0.001,2188.8,0.059,0.114,0.0062,36831.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-06",24,24,5470,,0.011,0.001,2178.2,0.059,0.096,0.0052,36649,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-07",10,9.05,2000.45,,0.004,0.001,813.375,0.059,0.047,0.0234,13686.375,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-16",7,5.09,0.84,,0.003,0.001,514.255,0.059,0.709,0.1713,8651.302,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-17",2,1.73,50.43,,0.001,0.001,177.245,0.059,0.233,0.1575,2982.89,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-20",18,17.03,3509,,0.009,0.001,1867.643,0.059,0.409,0.0347,31418.454,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-21",24,24,5874,,0.014,0.001,2687.6,0.059,0.15,0.0066,45219.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-22",24,24,5809,,0.014,0.001,2692.4,0.059,0.151,0.0067,45301.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-23",24,24,5799,,0.013,0.001,2572.2,0.059,0.165,0.0074,43268.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-24",24,24,5713,,0.013,0.001,2529.6,0.059,0.088,0.0041,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-25",24,24,5701,,0.013,0.001,2600.3,0.059,0.099,0.0045,43743.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-26",24,24,5790,,0.014,0.001,2720.4,0.059,0.125,0.0054,45774.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-27",24,24,5654,,0.013,0.001,2610.5,0.059,0.128,0.0058,43918.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-28",24,24,5773,,0.013,0.001,2662.4,0.059,0.13,0.0058,44797.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-29",24,24,5596,,0.013,0.001,2621.2,0.059,0.121,0.0054,44096.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-30",24,24,5547,,0.013,0.001,2603.6,0.059,0.117,0.0053,43799.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-03-31",24,24,5408,,0.013,0.001,2542.4,0.059,0.124,0.0058,42765.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-01",24,24,5594,,0.013,0.001,2634.4,0.059,0.144,0.0065,44322.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-02",24,24,5503,,0.013,0.001,2529.6,0.059,0.139,0.0065,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-03",24,24,5428,,0.013,0.001,2529.6,0.059,0.141,0.0066,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-04",24,24,5585,,0.013,0.001,2529.6,0.059,0.151,0.0071,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-05",24,24,6029,,0.013,0.001,2529.6,0.059,0.164,0.0077,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-06",24,24,5918,,0.013,0.001,2529.6,0.059,0.158,0.0074,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-07",24,24,5787,,0.013,0.001,2529.6,0.059,0.159,0.0075,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-08",16,15.8,3939,,0.008,0.001,1665.32,0.059,0.11,0.0079,28011.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-19",12,11.93,2262.53,,0.006,0.001,1256.492,0.059,0.591,0.057,21135.538,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-20",24,24,5773,,0.013,0.001,2529.6,0.059,0.153,0.0072,42549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-21",24,24,5733,,0.013,0.001,2556.6,0.059,0.171,0.008,43004.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-22",24,24,5668,,0.013,0.001,2573.6,0.059,0.17,0.0078,43292.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-23",24,24,5603,,0.013,0.001,2572.8,0.059,0.173,0.008,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-24",24,24,5648,,0.013,0.001,2572.8,0.059,0.168,0.0078,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-25",24,24,5700,,0.013,0.001,2572.8,0.059,0.137,0.0063,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-26",24,24,5467,,0.013,0.001,2572.8,0.059,0.133,0.0062,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-27",24,24,5248,,0.013,0.001,2572.8,0.059,0.146,0.0068,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-28",24,24,5613,,0.013,0.001,2572.8,0.059,0.142,0.0066,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-29",24,24,5577,,0.013,0.001,2572.8,0.059,0.129,0.006,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-04-30",24,24,5126,,0.013,0.001,2572.8,0.059,0.126,0.0058,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-01",24,24,5371,,0.013,0.001,2572.8,0.059,0.151,0.007,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-02",24,24,5274,,0.013,0.001,2572.8,0.059,0.124,0.0057,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-03",24,24,5286,,0.013,0.001,2572.8,0.059,0.127,0.0059,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-04",24,24,5600,,0.013,0.001,2572.8,0.059,0.15,0.0069,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-05",24,23.15,5343,,0.013,0.001,2481.605,0.059,0.131,0.0124,41742.835,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-06",2,1.08,32,,0.001,0.001,115.736,0.059,0.151,0.1655,1946.792,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-07",24,24,5344,,0.013,0.001,2572.8,0.059,0.327,0.0151,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-08",24,24,5659,,0.013,0.001,2572.8,0.059,0.132,0.0061,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-09",24,24,5716,,0.014,0.001,2687.1,0.059,0.139,0.0061,45202.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-10",24,24,5389,,0.013,0.001,2591.4,0.059,0.125,0.0057,43590.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-11",24,24,5559,,0.013,0.001,2671.9,0.059,0.141,0.0062,44946.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-12",24,24,5624,,0.013,0.001,2622.2,0.059,0.144,0.0065,44110.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-13",24,24,5422,,0.013,0.001,2664.9,0.059,0.146,0.0065,44828.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-14",24,24,5598,,0.013,0.001,2610.3,0.059,0.13,0.0059,43910.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-15",24,24,5355,,0.013,0.001,2589.9,0.059,0.109,0.005,43567.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-16",24,24,5704,,0.014,0.001,2680.4,0.059,0.117,0.0051,45090.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-17",24,24,5533,,0.014,0.001,2680.8,0.059,0.106,0.0046,45095.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-18",24,24,5257,,0.013,0.001,2572.8,0.059,0.121,0.0056,43276.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-19",24,24,5118,,0.013,0.001,2523.8,0.059,0.082,0.0039,42466.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-20",24,24,5175,,0.013,0.001,2488.8,0.059,0.092,0.0044,41887.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-21",24,24,5385,,0.013,0.001,2547.1,0.059,0.114,0.0053,42867,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-22",24,24,5408,,0.013,0.001,2557.3,0.059,0.087,0.004,43039.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-23",24,24,5256,,0.013,0.001,2508.4,0.059,0.087,0.0041,42215.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-24",24,24,5265,,0.013,0.001,2496.2,0.059,0.087,0.0041,42011.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-25",24,24,5654,,0.013,0.001,2640.6,0.059,0.115,0.0051,44437.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-26",24,24,5888,,0.013,0.001,2667.9,0.059,0.11,0.0048,44896.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-27",24,24,5805,,0.014,0.001,2701.4,0.059,0.089,0.0039,45460,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-28",24,24,5561,,0.013,0.001,2600.4,0.059,0.115,0.0052,43759.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-29",24,24,5587,,0.013,0.001,2599.5,0.059,0.131,0.006,43742.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-30",24,24,5347,,0.013,0.001,2507.1,0.059,0.127,0.006,42193.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-05-31",24,24,5319,,0.013,0.001,2516.8,0.059,0.127,0.006,42356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-01",24,24,5929,,0.013,0.001,2643.7,0.059,0.136,0.006,44488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-02",24,24,5903,,0.014,0.001,2678.8,0.059,0.138,0.0061,45078.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-03",24,24,6215,,0.014,0.001,2861.6,0.059,0.142,0.0058,48151.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-04",24,24,5920,,0.014,0.001,2763.5,0.059,0.128,0.0054,46505,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-05",24,24,5642,,0.013,0.001,2613.4,0.059,0.113,0.0051,43977.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-06",24,24,5271,,0.013,0.001,2515.7,0.059,0.09,0.0043,42336.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-07",24,24,5319,,0.013,0.001,2526.9,0.059,0.114,0.0053,42527.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-08",24,24,5588,,0.013,0.001,2587.7,0.059,0.105,0.0048,43549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-09",24,24,5765,,0.013,0.001,2649.8,0.059,0.115,0.005,44592.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-10",24,24,5906,,0.014,0.001,2682.4,0.059,0.132,0.0058,45140.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-11",24,24,5972,,0.014,0.001,2711.5,0.059,0.104,0.0045,45627.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-12",24,24,5751,,0.013,0.001,2604.1,0.059,0.096,0.0043,43821.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-13",24,24,5442,,0.013,0.001,2534.9,0.059,0.142,0.0067,42661.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-14",24,24,5403,,0.013,0.001,2552.3,0.059,0.128,0.006,42953.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-15",24,24,5658,,0.013,0.001,2607.3,0.059,0.143,0.0065,43878.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-16",24,24,5683,,0.013,0.001,2626.6,0.059,0.125,0.0055,44202.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-17",24,24,5359,,0.013,0.001,2552.6,0.059,0.116,0.0054,42958.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-18",24,24,5627,,0.013,0.001,2596.6,0.059,0.131,0.006,43697.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-19",24,24,5910,,0.013,0.001,2657.8,0.059,0.099,0.0044,44722.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-20",24,24,5722,,0.013,0.001,2605.1,0.059,0.097,0.0044,43839.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-21",24,24,5508,,0.013,0.001,2596.8,0.059,0.102,0.0046,43702,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-22",24,24,6132,,0.014,0.001,2804.4,0.059,0.15,0.0063,47188.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-23",24,24,6131,,0.014,0.001,2761.7,0.059,0.148,0.0063,46472.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-24",24,24,6068,,0.013,0.001,2641,0.059,0.123,0.0055,44434,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-25",24,24,5946,,0.013,0.001,2611.5,0.059,0.121,0.0054,43941.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-26",24,24,6140,,0.014,0.001,2683.1,0.059,0.136,0.006,45147.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-27",24,24,6088,,0.014,0.001,2691.4,0.059,0.133,0.0058,45284.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-28",24,24,5696,,0.013,0.001,2536.1,0.059,0.11,0.005,42668.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-29",24,24,5505,,0.012,0.001,2426.3,0.059,0.113,0.0055,40816.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-06-30",24,24,5412,,0.012,0.001,2423.7,0.059,0.087,0.0042,40772.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-01",24,24,5665,,0.012,0.001,2466.1,0.059,0.092,0.0044,41488.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-02",24,24,5518,,0.012,0.001,2449.8,0.059,0.083,0.0039,41209.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-03",24,24,5926,,0.013,0.001,2564.2,0.059,0.106,0.0048,43141.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-04",24,24,6024,,0.013,0.001,2641.3,0.059,0.128,0.0057,44441.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-05",24,24,5997,,0.013,0.001,2619.4,0.059,0.135,0.0061,44072.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-06",24,24,5772,,0.013,0.001,2495,0.059,0.127,0.006,41979.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-07",24,24,5739,,0.013,0.001,2515.8,0.059,0.1,0.0047,42329.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-08",24,24,5710,,0.013,0.001,2496.2,0.059,0.102,0.0048,41992.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-09",24,24,5774,,0.013,0.001,2527.7,0.059,0.117,0.0055,42524.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-10",24,24,5815,,0.013,0.001,2548.1,0.059,0.101,0.0046,42868.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-11",24,24,6037,,0.013,0.001,2622.9,0.059,0.114,0.0051,44130.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-12",24,24,5929,,0.013,0.001,2612.6,0.059,0.105,0.0047,43954.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-13",24,24,5873,,0.013,0.001,2563,0.059,0.105,0.0048,43121.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-14",24,24,5699,,0.013,0.001,2479.3,0.059,0.127,0.006,41710.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-15",24,24,5482,,0.012,0.001,2436,0.059,0.105,0.005,40977.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-16",24,24,5355,,0.012,0.001,2414.2,0.059,0.096,0.0047,40610.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-17",24,24,5658,,0.013,0.001,2513.2,0.059,0.108,0.005,42280.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-18",24,24,5936,,0.013,0.001,2633.3,0.059,0.114,0.0051,44308.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-19",24,24,5560,,0.012,0.001,2459,0.059,0.082,0.0039,41367.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-20",24,24,5568,,0.012,0.001,2470.6,0.059,0.083,0.0039,41562.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-21",24,24,5997,,0.013,0.001,2608.8,0.059,0.113,0.0051,43894,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-22",24,24,5711,,0.013,0.001,2554,0.059,0.094,0.0043,42974.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-23",24,24,5644,,0.013,0.001,2526.6,0.059,0.093,0.0043,42523.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-24",24,24,5764,,0.013,0.001,2577.4,0.059,0.116,0.0052,43384.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-25",24,24,6060,,0.014,0.001,2700.1,0.059,0.133,0.0058,45447.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-26",24,24,6079,,0.014,0.001,2714.3,0.059,0.126,0.0055,45687.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-27",24,24,6057,,0.013,0.001,2645.2,0.059,0.127,0.0056,44518.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-28",24,24,6069,,0.013,0.001,2667.3,0.059,0.118,0.0052,44893.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-29",24,24,6030,,0.013,0.001,2649.8,0.059,0.119,0.0053,44600.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-30",24,24,5914,,0.013,0.001,2609.6,0.059,0.107,0.0048,43921.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-07-31",24,24,6001,,0.014,0.001,2685.7,0.059,0.122,0.0053,45206.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-01",24,24,5617,,0.013,0.001,2509.6,0.059,0.089,0.0041,42241.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-02",24,24,5809,,0.013,0.001,2605,0.059,0.109,0.0049,43846.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-03",24,24,5666,,0.013,0.001,2529.8,0.059,0.096,0.0044,42581.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-04",24,24,5633,,0.013,0.001,2506,0.059,0.112,0.0053,42174.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-05",24,24,5510,,0.012,0.001,2474.9,0.059,0.095,0.0045,41658.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-06",24,24,5448,,0.012,0.001,2452,0.059,0.092,0.0044,41271.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-07",24,24,5677,,0.013,0.001,2574.9,0.059,0.097,0.0044,43338.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-08",24,24,5745,,0.013,0.001,2593.8,0.059,0.095,0.0043,43655.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-09",24,24,5838,,0.013,0.001,2627.7,0.059,0.116,0.0052,44229.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-10",24,24,5958,,0.013,0.001,2667.2,0.059,0.12,0.0053,44891.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-11",24,24,5725,,0.013,0.001,2582,0.059,0.1,0.0045,43460.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-12",24,24,5882,,0.013,0.001,2639.4,0.059,0.107,0.0048,44424.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-13",24,24,6189,,0.014,0.001,2730.4,0.059,0.131,0.0057,45959.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-14",24,24,6042,,0.014,0.001,2705,0.059,0.121,0.0053,45531.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-15",24,24,5996,,0.014,0.001,2695.2,0.059,0.124,0.0054,45369.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-16",24,24,5588,,0.013,0.001,2565.7,0.059,0.096,0.0044,43184.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-17",24,24,5654,,0.013,0.001,2566.9,0.059,0.096,0.0043,43205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-18",24,24,5554,,0.013,0.001,2553.3,0.059,0.088,0.004,42966.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-19",24,24,5465,,0.013,0.001,2530.1,0.059,0.076,0.0035,42571.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-20",24,24,5034,,0.012,0.001,2400,0.059,0.051,0.0025,40382.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-21",24,24,5255,,0.012,0.001,2413.3,0.059,0.072,0.0035,40605.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-22",24,24,5998,,0.014,0.001,2708.5,0.059,0.139,0.006,45568.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-23",24,24,6033,,0.014,0.001,2738,0.059,0.14,0.006,46065.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-24",24,24,6188,,0.014,0.001,2802.4,0.059,0.148,0.0063,47147.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-25",24,24,5877,,0.014,0.001,2688.1,0.059,0.117,0.0051,45227.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-26",24,24,5272,,0.012,0.001,2457.5,0.059,0.07,0.0034,41352.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-27",24,24,5142,,0.012,0.001,2416.7,0.059,0.068,0.0033,40664.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-28",24,24,5648,,0.013,0.001,2558.6,0.059,0.098,0.0045,43050.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-29",24,24,5569,,0.013,0.001,2552.5,0.059,0.086,0.004,42949.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-30",24,24,5336,,0.012,0.001,2459.6,0.059,0.078,0.0037,41383.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-08-31",24,24,5501,,0.013,0.001,2512.4,0.059,0.091,0.0043,42271.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-01",24,24,5910,,0.014,0.001,2681,0.059,0.122,0.0053,45106.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-02",24,24,5715,,0.013,0.001,2615.8,0.059,0.104,0.0046,44011,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-03",24,24,6096,,0.014,0.001,2720.6,0.059,0.133,0.0058,45774.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-04",24,24,6097,,0.014,0.001,2735.9,0.059,0.131,0.0056,46029.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-05",24,24,5226,,0.012,0.001,2432.1,0.059,0.074,0.0036,40923,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-06",24,24,5530,,0.013,0.001,2589.9,0.059,0.097,0.0044,43575.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-07",24,24,5546,,0.013,0.001,2588.7,0.059,0.092,0.0041,43557.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-08",24,24,5253,,0.012,0.001,2454.5,0.059,0.074,0.0035,41298.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-09",24,24,5555,,0.013,0.001,2541.3,0.059,0.088,0.004,42761.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-10",24,24,6112,,0.014,0.001,2716.7,0.059,0.131,0.0057,45709.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-11",24,24,6406,,0.014,0.001,2819.9,0.059,0.153,0.0064,47442.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-12",24,24,6252,,0.014,0.001,2768.6,0.059,0.135,0.0058,46580.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-13",24,24,6177,,0.014,0.001,2757.4,0.059,0.126,0.0054,46391.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-14",24,24,6391,,0.014,0.001,2827.1,0.059,0.134,0.0056,47563.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-15",24,24,6388,,0.014,0.001,2834.5,0.059,0.134,0.0056,47686.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-16",24,24,6269,,0.014,0.001,2786.9,0.059,0.136,0.0058,46886.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-17",24,24,6360,,0.014,0.001,2826.7,0.059,0.143,0.006,47555.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-18",24,24,6244,,0.014,0.001,2783.4,0.059,0.134,0.0057,46826.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-19",24,24,6191,,0.014,0.001,2751.2,0.059,0.15,0.0064,46286.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-20",24,24,6175,,0.014,0.001,2761,0.059,0.153,0.0065,46452.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-21",24,24,6349,,0.014,0.001,2809.2,0.059,0.161,0.0068,47261.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-22",24,24,6350,,0.015,0.001,2915.2,0.059,0.156,0.0064,49045.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-23",24,24,6413,,0.015,0.001,3038.4,0.059,0.162,0.0063,51115.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-24",24,24,5873,,0.014,0.001,2815.1,0.059,0.125,0.0052,47366,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-25",24,24,6053,,0.015,0.001,2895.1,0.059,0.144,0.0058,48714.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-26",24,24,5626,,0.014,0.001,2752.2,0.059,0.119,0.005,46316.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-27",24,24,5627,,0.014,0.001,2756.1,0.059,0.102,0.0043,46377.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-28",24,24,5729,,0.014,0.001,2790.1,0.059,0.113,0.0047,46948.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-29",24,24,6044,,0.015,0.001,2943.3,0.059,0.135,0.0054,49520.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-09-30",24,24,6279,,0.015,0.001,3001.9,0.059,0.163,0.0064,50503.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-01",24,24,6225,,0.015,0.001,2977.1,0.059,0.16,0.0063,50085.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-02",24,24,6216,,0.015,0.001,2974.9,0.059,0.142,0.0057,50048.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-03",24,24,6211,,0.015,0.001,2984.3,0.059,0.126,0.005,50206.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-04",24,24,6168,,0.015,0.001,2960.8,0.059,0.139,0.0055,49812.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-05",24,24,6406,,0.015,0.001,3038.4,0.059,0.166,0.0065,51115.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-06",24,24,6462,,0.015,0.001,3038.4,0.059,0.137,0.0054,51115.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-07",24,24,6144,,0.014,0.001,2826.7,0.059,0.175,0.0074,47561.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-08",24,24,6255,,0.015,0.001,2989.9,0.059,0.155,0.0061,50302.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-09",24,24,6196,,0.015,0.001,2943.4,0.059,0.148,0.0059,49523.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-10",24,24,5951,,0.014,0.001,2862,0.059,0.134,0.0055,48153.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-11",24,24,5917,,0.014,0.001,2869.5,0.059,0.131,0.0053,48281.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-12",24,24,6332,,0.015,0.001,3002.3,0.059,0.159,0.0063,50509.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-13",24,24,6421,,0.015,0.001,3037,0.059,0.16,0.0063,51092.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-14",24,24,6018,,0.015,0.001,2877.3,0.059,0.117,0.0048,48411.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-15",24,24,6144,,0.015,0.001,2941.6,0.059,0.131,0.0053,49491.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-16",24,24,5955,,0.015,0.001,2894.7,0.059,0.12,0.0049,48702,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-17",24,24,5851,,0.014,0.001,2835,0.059,0.117,0.0048,47704.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-18",24,24,6217,,0.015,0.001,2975,0.059,0.155,0.0061,50051.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-19",24,24,6337,,0.015,0.001,3007.6,0.059,0.166,0.0065,50598.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-20",24,24,6305,,0.015,0.001,2919.7,0.059,0.161,0.0065,49131.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-21",24,24,6156,,0.014,0.001,2787.1,0.059,0.127,0.0054,46904.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-22",24,24,6111,,0.014,0.001,2826.4,0.059,0.137,0.0057,47566.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-23",24,24,6114,,0.014,0.001,2738.5,0.059,0.131,0.0057,46085.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-24",24,24,6311,,0.014,0.001,2841.6,0.059,0.152,0.0063,47824.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-25",24,24,6130,,0.014,0.001,2817.8,0.059,0.147,0.0061,47425.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-26",24,24,6173,,0.014,0.001,2785.8,0.059,0.13,0.0055,46883.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-27",24,24,6080,,0.014,0.001,2767.7,0.059,0.126,0.0053,46578.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-28",24,24,5803,,0.013,0.001,2663.9,0.059,0.103,0.0045,44829.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-29",24,24,5869,,0.013,0.001,2637.3,0.059,0.121,0.0053,44383,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-30",24,24,6028,,0.014,0.001,2735.7,0.059,0.136,0.0058,46038.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-10-31",24,24,5955,,0.014,0.001,2709.5,0.059,0.125,0.0054,45597.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-01",24,24,6086,,0.014,0.001,2780.7,0.059,0.141,0.0059,46796.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-02",24,24,5959,,0.013,0.001,2618.7,0.059,0.145,0.0066,44069.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-03",24,24,5668,,0.012,0.001,2457.6,0.059,0.116,0.0056,41354.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-04",24,24,5635,,0.012,0.001,2457.6,0.059,0.096,0.0047,41354.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-05",24,24,5639,,0.012,0.001,2457.6,0.059,0.095,0.0046,41354.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-06",24,24,5615,,0.012,0.001,2457.6,0.059,0.121,0.0059,41354.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-07",24,24,5609,,0.012,0.001,2457.6,0.059,0.115,0.0055,41354.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-08",24,24,5607,,0.012,0.001,2457.6,0.059,0.128,0.0062,41354.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-09",11,10.32,2370.04,,0.005,0.001,1056.928,0.059,0.062,0.0075,17784.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-19",14,13.25,2710.5,,0.007,0.001,1312.525,0.059,0.437,0.0396,22084.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-20",24,24,5935,,0.012,0.001,2381.7,0.059,0.14,0.007,40071.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-21",24,24,5948,,0.012,0.001,2446.6,0.059,0.111,0.0054,41164.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-22",24,24,5862,,0.013,0.001,2495.1,0.059,0.097,0.0046,41981.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-23",24,24,5991,,0.012,0.001,2434.3,0.059,0.099,0.0048,40956.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-24",24,24,5964,,0.012,0.001,2476.2,0.059,0.102,0.0048,41662.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-25",24,24,5822,,0.012,0.001,2427.2,0.059,0.09,0.0044,40836.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-26",24,24,5781,,0.012,0.001,2453.9,0.059,0.09,0.0043,41288.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-27",24,24,5613,,0.012,0.001,2328.8,0.059,0.081,0.0041,39181.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-28",24,24,5895,,0.012,0.001,2450.3,0.059,0.087,0.0042,41225.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-29",24,24,5959,,0.013,0.001,2523.6,0.059,0.098,0.0045,42460.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-11-30",24,24,5998,,0.013,0.001,2485.7,0.059,0.101,0.0048,41821.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-01",24,24,6072,,0.013,0.001,2533.1,0.059,0.096,0.0045,42620.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-02",24,24,5893,,0.012,0.001,2442.7,0.059,0.088,0.0042,41098.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-03",24,24,6019,,0.012,0.001,2453.6,0.059,0.096,0.0046,41282,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-04",24,24,6021,,0.012,0.001,2448.5,0.059,0.099,0.0048,41196.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-05",24,24,5893,,0.012,0.001,2422.4,0.059,0.099,0.0048,40756.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-06",24,24,5713,,0.012,0.001,2374.2,0.059,0.093,0.0046,39945,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-07",24,24,5942,,0.012,0.001,2445.5,0.059,0.101,0.0048,41146.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-08",24,24,5945,,0.012,0.001,2428.2,0.059,0.098,0.0048,40853,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-09",24,24,5853,,0.012,0.001,2422.3,0.059,0.093,0.0045,40757,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-10",24,24,6061,,0.013,0.001,2490,0.059,0.103,0.0049,41896.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-11",24,24,6115,,0.013,0.001,2517,0.059,0.116,0.0054,42354.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-12",24,24,6008,,0.012,0.001,2475,0.059,0.105,0.005,41643.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-13",24,24,6075,,0.013,0.001,2524.8,0.059,0.106,0.005,42481,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-14",24,24,5766,,0.012,0.001,2421.8,0.059,0.084,0.0041,40745.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-15",9,7.28,1433.11,,0.004,0.001,733.984,0.059,0.441,0.101,12349.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-16",24,24,6108,,0.013,0.001,2483.5,0.059,0.097,0.0046,41785.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-17",24,24,5329,,0.012,0.001,2296.5,0.059,0.072,0.0038,38636.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-18",24,24,5548,,0.012,0.001,2368.2,0.059,0.09,0.0045,39842.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-19",24,24,5591,,0.012,0.001,2386.9,0.059,0.086,0.0042,40159.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-20",24,24,5728,,0.012,0.001,2404.5,0.059,0.086,0.0042,40455.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-21",24,24,5944,,0.012,0.001,2361.2,0.059,0.09,0.0045,39725.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-22",24,24,5813,,0.012,0.001,2366.2,0.059,0.087,0.0043,39810.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-23",24,24,5908,,0.012,0.001,2452.2,0.059,0.098,0.0047,41256.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-24",24,24,6029,,0.013,0.001,2499.2,0.059,0.101,0.0048,42050.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-25",24,24,5699,,0.012,0.001,2321.6,0.059,0.08,0.0041,39060.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-26",24,24,5442,,0.012,0.001,2287.2,0.059,0.072,0.0038,38479.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-27",24,24,5935,,0.012,0.001,2462.3,0.059,0.094,0.0045,41429.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-28",24,24,6158,,0.013,0.001,2522.7,0.059,0.105,0.0049,42442.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-29",24,24,5908,,0.012,0.001,2445.6,0.059,0.082,0.004,41138.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-30",24,24,5621,,0.012,0.001,2346.1,0.059,0.072,0.0037,39459.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Elk Hills Power",55400,"CTG-2",,"2020-12-31",24,24,5816,,0.012,0.001,2472.8,0.059,0.087,0.0041,41597,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-16",2,1.15,48.76,,0,0.001,31.326,0.058,0.006,0.0445,537.694,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-02",2,1.12,44.73,,0,0.001,29.001,0.058,0.003,0.0145,498.494,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-24",4,2.22,90.06,,0,0.001,56.816,0.058,0.014,0.0223,974.844,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-26",4,2.5,81.28,,0,0.001,52.208,0.058,0.008,0.0198,897.154,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-01",2,1.17,45.96,,0,0.001,29.86,0.058,0.005,0.019,512.692,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-02",2,1.14,44.33,,0,0.001,28.145,0.058,0.009,0.0395,483.729,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-04",2,1.15,46.78,,0,0.001,29.443,0.058,0.006,0.02,506.584,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-12",2,1.17,46.02,,0,0.001,29.82,0.058,0.007,0.026,512.193,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-15",1,0.12,0,,0,0.001,0.528,0.058,0,0.069,9.072,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-17",2,1.1,43.2,,0,0.001,27.58,0.058,0.006,0.0265,474.45,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-21",2,1.2,47.34,,0,0.001,30.684,0.058,0.006,0.02,526.26,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-07",1,0.03,0,,0,0.001,0.156,0.058,0,0.057,2.697,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-09",1,0.15,0,,0,0.001,0.87,0.058,0,0.057,14.97,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-15",1,0.02,0,,0,0.001,0.07,0.058,0,0.045,1.202,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-16",1,0.57,21.09,,0,0.001,13.737,0.058,0.007,0.058,235.752,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-22",2,1.03,40.95,,0,0.001,26.7,0.058,0.004,0.014,457.958,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-24",2,1.28,54.43,,0,0.001,33.912,0.058,0.007,0.025,582.522,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-25",2,1.17,48.15,,0,0.001,31.275,0.058,0.004,0.0195,537.102,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-11",3,1.27,42.5,,0,0.001,28.92,0.058,0.004,0.0347,496.244,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-13",3,1.17,49.62,,0,0.001,31.313,0.058,0.007,0.0607,538.366,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-14",2,1.19,47.52,,0,0.001,30.24,0.058,0.005,0.019,519.406,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-15",2,1.17,46.87,,0,0.001,30.298,0.058,0.004,0.013,520.827,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-16",2,1.44,59.28,,0,0.001,37.464,0.058,0.003,0.0115,642.816,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-21",5,2.87,121.4,,0,0.001,76.739,0.058,0.007,0.0138,1317.039,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-22",3,2.22,103.41,,0,0.001,62.201,0.058,0.01,0.019,1067.312,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-23",2,1.22,49.98,,0,0.001,32.268,0.058,0.005,0.0235,554.66,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-25",6,4.38,191.67,,0.001,0.001,119.068,0.058,0.014,0.0143,2044.061,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-26",8,7.45,337.45,,0.001,0.001,208.249,0.058,0.02,0.0111,3578.529,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-27",10,8.24,360.95,,0.001,0.001,223.274,0.058,0.02,0.0104,3833.199,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-29",2,1.22,50.24,,0,0.001,31.844,0.058,0.003,0.011,547.39,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-01",2,1.1,45.4,,0,0.001,28.74,0.058,0.003,0.0145,493.65,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-02",2,1.15,46.55,,0,0.001,29.675,0.058,0.003,0.0105,510.05,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-03",5,4.06,177.38,,0.001,0.001,108.024,0.058,0.011,0.0124,1853.112,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-04",5,3.41,141.03,,0,0.001,87.604,0.058,0.009,0.0118,1504.982,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-08",3,1.93,81.65,,0,0.001,51.37,0.058,0.005,0.011,882.369,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-09",5,3.92,178.64,,0.001,0.001,108.608,0.058,0.011,0.0128,1864.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-10",3,1.67,71.54,,0,0.001,44.812,0.058,0.006,0.022,769.816,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-11",3,2.17,91.62,,0,0.001,57.483,0.058,0.006,0.0117,987.475,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-16",1,0.02,0,,0,0.001,0.052,0.057,0,0.025,0.908,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-18",2,1.2,48.12,,0,0.001,30.978,0.058,0.003,0.011,532.35,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-22",3,1.92,79.6,,0,0.001,50.654,0.058,0.008,0.0227,869.104,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-23",3,2.15,91.55,,0,0.001,57.4,0.058,0.006,0.0137,986.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-24",3,1.9,78.68,,0,0.001,49.59,0.058,0.005,0.0133,852.044,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-26",3,1.9,76.9,,0,0.001,48.19,0.058,0.007,0.018,827.88,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-27",3,1.6,68.04,,0,0.001,42.88,0.058,0.005,0.0187,736.084,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-06-30",4,2.9,132.42,,0,0.001,80.942,0.058,0.009,0.0148,1389.62,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-03",2,1.2,50.88,,0,0.001,32.316,0.058,0.005,0.025,554.568,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-04",3,2.13,97.2,,0,0.001,60.073,0.058,0.006,0.013,1031.65,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-05",3,2.15,91.9,,0,0.001,56.985,0.058,0.007,0.0167,978.73,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-06",2,1.17,47.94,,0,0.001,31.191,0.058,0.004,0.0145,535.059,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-07",3,1.17,47.27,,0,0.001,30.692,0.058,0.004,0.0447,526.553,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-08",2,1.4,58.1,,0,0.001,37.24,0.058,0.004,0.015,638.96,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-09",4,3.42,150.88,,0,0.001,93.062,0.058,0.009,0.0135,1598.288,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-10",4,2.92,125.52,,0,0.001,77.452,0.058,0.007,0.011,1329.128,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-11",7,5.9,270.04,,0.001,0.001,165.222,0.058,0.014,0.0103,2837.96,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-12",7,5.28,222.88,,0.001,0.001,136.118,0.058,0.014,0.0209,2337.941,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-13",2,1.03,40.6,,0,0.001,26.533,0.058,0.002,0.013,455.421,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-14",6,5.3,238.48,,0.001,0.001,145.754,0.058,0.013,0.0103,2502.696,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-15",10,9.07,402.15,,0.001,0.001,245.912,0.058,0.019,0.0098,4222.051,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-20",10,8.61,381.85,,0.001,0.001,233.513,0.058,0.023,0.0108,4010.51,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-24",4,3.67,133.21,,0,0.001,84.411,0.058,0.008,0.0108,1449.608,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-25",3,1.67,70.95,,0,0.001,44.522,0.058,0.005,0.0137,764.69,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-26",4,3.18,137.25,,0,0.001,83.283,0.058,0.009,0.0145,1431.04,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-27",4,3.17,136.8,,0,0.001,84.357,0.058,0.009,0.013,1450.025,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-28",2,1.44,59.28,,0,0.001,37.488,0.058,0.005,0.016,644.408,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-29",4,3.49,151.96,,0,0.001,93.345,0.058,0.01,0.0133,1603.701,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-30",5,3.97,172.22,,0.001,0.001,105.002,0.058,0.01,0.0132,1803.928,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-07-31",3,1.87,81.18,,0,0.001,49.291,0.058,0.007,0.0167,846.344,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-03",2,1.15,47.34,,0,0.001,30.116,0.058,0.003,0.0135,517.147,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-06",2,1.48,60.62,,0,0.001,37.798,0.058,0.004,0.0135,647.984,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-07",3,1.24,48.97,,0,0.001,30.822,0.058,0.006,0.093,529.048,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-09",4,2.45,102.3,,0,0.001,64.782,0.058,0.006,0.0133,1110.764,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-10",3,2.49,104.47,,0,0.001,64.569,0.058,0.006,0.0117,1108.748,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-11",2,1.15,48.23,,0,0.001,30.436,0.058,0.004,0.018,522.499,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-12",4,3.44,149.28,,0,0.001,92.3,0.058,0.01,0.014,1583.708,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-13",5,4.37,191.29,,0.001,0.001,117.388,0.058,0.011,0.0112,2015.057,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-14",8,7.19,312,,0.001,0.001,190.869,0.058,0.018,0.0111,3275.855,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-15",8,7.2,315.4,,0.001,0.001,193.42,0.058,0.02,0.0133,3320.74,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-16",3,2.49,103.12,,0,0.001,64.79,0.058,0.009,0.019,1113.614,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-17",10,9.18,397.6,,0.001,0.001,245.347,0.058,0.024,0.012,4213.662,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-18",12,10.99,478.03,,0.002,0.001,292.379,0.058,0.027,0.0164,5022.487,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-19",4,2.7,113.19,,0,0.001,69.192,0.058,0.011,0.023,1187.733,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-22",6,4.11,168.98,,0.001,0.001,104.929,0.058,0.012,0.0198,1803.182,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-23",3,1.16,47.92,,0,0.001,29.32,0.058,0.003,0.0207,503.232,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-24",4,2.93,123.52,,0,0.001,76.123,0.058,0.009,0.0195,1307.907,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-25",2,1.13,46.57,,0,0.001,29.436,0.058,0.004,0.0165,505.602,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-27",2,0.97,39.18,,0,0.001,24.568,0.058,0.004,0.0195,421.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-28",3,1.67,70.08,,0,0.001,43.723,0.058,0.005,0.0123,750.767,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-29",2,1.2,47.22,,0,0.001,29.814,0.058,0.003,0.0125,512.784,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-03",2,1.15,47.6,,0,0.001,30.24,0.058,0.003,0.0115,519.585,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-04",2,1.02,39.42,,0,0.001,25.182,0.058,0.003,0.012,432.42,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-05",4,2.69,117.31,,0,0.001,73.329,0.058,0.01,0.0175,1259.014,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-06",6,5.45,238.81,,0.001,0.001,146.105,0.058,0.014,0.0117,2507.634,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-11",3,1.19,46.63,,0,0.001,30.376,0.058,0.005,0.0267,521.38,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-14",3,2.16,88.92,,0,0.001,55.528,0.058,0.007,0.017,953.852,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-15",2,1.15,42.71,,0,0.001,26.797,0.058,0.004,0.0175,460.264,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-16",4,2.44,93.63,,0,0.001,59.102,0.058,0.008,0.016,1014.645,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-17",5,2.82,111.11,,0,0.001,70.197,0.058,0.009,0.0182,1205.526,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-18",3,1.64,65.76,,0,0.001,42.176,0.058,0.005,0.0137,724.768,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-19",3,2.69,107.46,,0,0.001,67.521,0.058,0.006,0.0103,1159.601,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-20",3,1.72,66.97,,0,0.001,43.323,0.058,0.005,0.015,744.73,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-26",1,0.1,0,,0,0.001,0.69,0.058,0,0.037,11.92,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-27",2,1.17,44.28,,0,0.001,28.451,0.058,0.003,0.012,488.957,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-28",4,3.4,107.92,,0,0.001,68.924,0.058,0.008,0.0138,1183.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-29",4,2.63,82.41,,0,0.001,52.353,0.058,0.007,0.0135,899.635,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-06",1,0.32,5.12,,0,0.001,3.424,0.058,0.001,0.039,58.912,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-12",3,1.2,24.48,,0,0.0007,15.963,0.058,0.003,0.0273,273.386,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-13",3,1.66,33.64,,0,0.001,21.67,0.058,0.003,0.0193,372.302,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-14",4,3.18,72.66,,0,0.001,43.789,0.058,0.005,0.0153,751.84,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-15",4,2.87,62.14,,0,0.001,38.491,0.058,0.004,0.0123,661.863,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-16",3,1.61,33.47,,0,0.001,20.714,0.058,0.003,0.0167,355.123,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-19",3,1.65,33.58,,0,0.001,21.342,0.058,0.003,0.0193,367.349,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-30",2,0.14,0,,0,0,0.176,0.0585,0,0.0945,3.026,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-02",2,1.2,47.44,,0,0.001,30.452,0.058,0.005,0.0195,522.696,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-04",4,2.95,129.34,,0,0.001,79.235,0.058,0.008,0.0135,1360.678,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-05",5,4.4,197,,0.001,0.001,120.08,0.058,0.012,0.012,2062.144,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-09",2,1.18,45.94,,0,0.001,29.176,0.058,0.011,0.0385,501.298,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-10",6,3.76,163.35,,0.001,0.001,100.975,0.058,0.013,0.0172,1734.556,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-11",4,3.14,134.8,,0,0.001,83.048,0.058,0.01,0.0175,1426.948,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-12",3,2.19,96.19,,0,0.001,59.091,0.058,0.007,0.0143,1013.236,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-13",2,1.15,47.97,,0,0.001,30.746,0.058,0.004,0.0165,527.986,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-14",3,1.7,69.85,,0,0.001,43.734,0.058,0.005,0.014,751.23,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-15",4,2.66,127.29,,0,0.001,76.385,0.058,0.009,0.016,1311.826,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-16",3,1.72,72.45,,0,0.001,44.861,0.058,0.004,0.0107,770.029,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-17",4,2.91,126.77,,0,0.001,78.207,0.058,0.007,0.0123,1344.565,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-18",4,2.37,95.02,,0,0.001,60.433,0.058,0.005,0.0103,1038.498,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-19",3,1.73,72.09,,0,0.001,45.465,0.058,0.006,0.0223,780.177,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-20",3,1.7,70.55,,0,0.001,44.001,0.058,0.006,0.0153,756.265,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-21",3,1.9,80.94,,0,0.001,50.346,0.058,0.005,0.013,865.112,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-22",3,1.97,82.77,,0,0.001,51.784,0.058,0.005,0.0113,889.826,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-23",2,1.15,47.19,,0,0.001,30.558,0.058,0.005,0.018,524.508,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-24",7,4.41,193.5,,0.001,0.001,119.955,0.058,0.014,0.0303,2060.003,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-25",2,1.2,48.12,,0,0.001,31.458,0.058,0.004,0.014,540.318,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-27",2,1.19,47.52,,0,0.001,30.947,0.058,0.005,0.0195,531.453,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-28",2,1.2,47.34,,0,0.001,30.744,0.058,0.005,0.018,527.646,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-29",3,1.95,81.87,,0,0.001,51.831,0.058,0.007,0.0183,889.141,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-11-30",4,2.71,119.34,,0,0.001,74.234,0.058,0.009,0.0178,1275.269,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-01",6,4.65,201.84,,0.001,0.001,125.187,0.058,0.014,0.015,2150.53,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-02",6,4.27,186.93,,0.001,0.001,115.494,0.058,0.013,0.0135,1983.864,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-03",8,6.89,304.92,,0.001,0.001,188.285,0.058,0.019,0.013,3233.099,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-08",3,2.69,120.14,,0,0.001,73.186,0.058,0.007,0.0117,1257.527,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-09",5,4.2,187.17,,0.001,0.001,114.369,0.058,0.013,0.015,1962.43,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-10",7,5.64,250.18,,0.001,0.001,154.652,0.058,0.017,0.0144,2655.956,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-11",7,5.42,244.9,,0.001,0.001,150.438,0.058,0.026,0.0223,2583.923,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-12",6,5.45,242.2,,0.001,0.001,147.151,0.058,0.015,0.0133,2529.116,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-13",4,2.37,100.67,,0,0.001,62.934,0.058,0.009,0.0178,1081.504,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-14",8,6.87,302.95,,0.001,0.001,186.636,0.058,0.018,0.0124,3207.021,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-15",10,8.36,380.53,,0.001,0.001,232.676,0.058,0.025,0.0141,3995.629,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-16",7,5.98,273.94,,0.001,0.001,167.078,0.058,0.019,0.015,2868.913,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-18",7,5.43,236.92,,0.001,0.001,148.625,0.058,0.017,0.0136,2550.462,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-19",5,3.1,131.46,,0,0.001,83.419,0.058,0.01,0.0168,1432.388,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-20",1,0.25,11.25,,0,0.001,6.75,0.058,0.002,0.032,116.075,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-22",1,0.17,0,,0,0.001,0.884,0.058,0,0.062,15.283,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-23",4,2.41,104.41,,0,0.001,65.12,0.058,0.009,0.0168,1118.251,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-24",2,1.24,52.82,,0,0.001,33.276,0.058,0.003,0.012,571.614,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-27",4,3.15,138.03,,0,0.001,84.833,0.058,0.007,0.0105,1456.828,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-28",6,3.81,159.55,,0.001,0.001,100.199,0.058,0.012,0.0163,1722.154,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Vaca Dixon",55499,"GT-1",,"2020-12-31",3,1.69,70.62,,0,0.001,44.576,0.058,0.006,0.0167,765.073,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-27",1,0.18,1.44,,0,0.001,2.592,0.059,0.001,0.056,44.19,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-01",2,1.1,40.7,,0,0.001,27.296,0.059,0.003,0.025,465.224,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-02",1,0.08,0,,0,0.001,0.056,0.059,0,0.029,0.944,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-14",2,1.4,57.95,,0,0.001,37.362,0.059,0.004,0.012,636.349,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-21",2,1.13,40.69,,0,0.001,26.58,0.059,0.003,0.0115,453.41,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-04",2,1.09,43.1,,0,0.001,28.183,0.059,0.003,0.013,479.799,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-09",2,1.12,43.92,,0,0.001,28.854,0.059,0.003,0.014,490.832,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-14",2,1.07,42.79,,0,0.001,28.702,0.059,0.003,0.011,489.847,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-22",1,0.08,0,,0,0.001,0.448,0.059,0,0.043,7.656,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-23",1,0.05,0,,0,0.001,0.315,0.059,0,0.035,5.35,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-24",2,1,37.34,,0,0.001,24.832,0.059,0.003,0.012,422.881,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-27",6,4.7,205.65,,0.001,0.001,128.435,0.059,0.013,0.0115,2189.355,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-28",10,9.32,417.4,,0.001,0.001,259.504,0.059,0.025,0.0113,4424.68,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-04-30",2,0.11,0,,0,0.001,0.539,0.058,0,0.037,9.208,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-02",2,1.1,43.1,,0,0.001,28.35,0.059,0.003,0.015,483.21,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-07",2,1.1,41.84,,0,0.001,28.562,0.059,0.003,0.0135,486.936,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-08",3,1.8,73.74,,0,0.001,47.47,0.059,0.005,0.0133,809.374,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-09",3,2.15,90.63,,0,0.001,57.873,0.059,0.006,0.013,986.185,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-11",2,1.14,44.7,,0,0.001,28.848,0.059,0.003,0.0145,491.652,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-16",2,1.2,29.16,,0,0.001,19.355,0.059,0.002,0.01,330.059,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-22",1,0.23,10.12,,0,0.001,5.773,0.059,0.001,0.017,98.486,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-23",1,0.15,6.6,,0,0.001,4.17,0.059,0,0.009,71.145,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-25",4,2.69,113.89,,0,0.001,72.584,0.059,0.008,0.0153,1236.487,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-26",3,1.6,56,,0,0.001,36.38,0.059,0.014,0.0417,620.21,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-27",3,1.75,47.97,,0,0.001,31.789,0.0587,0.003,0.0123,541.421,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-02",2,1.15,44.39,,0,0.001,29.118,0.059,0.003,0.0145,496.823,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-03",6,4.42,180.09,,0.001,0.001,114.488,0.059,0.012,0.012,1950.482,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-04",3,1.87,75.67,,0,0.001,48.291,0.059,0.005,0.0127,822.816,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-08",3,2.15,87.15,,0,0.001,55.625,0.059,0.005,0.0123,947.845,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-09",4,2.65,110.65,,0,0.001,70.417,0.059,0.007,0.0153,1200.443,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-10",6,4.62,194.72,,0.001,0.001,124.235,0.059,0.013,0.0123,2117.971,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-11",3,2.16,90.6,,0,0.001,57.184,0.059,0.006,0.0117,975.076,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-16",2,1.23,46.65,,0,0.001,30.411,0.059,0.003,0.0115,518.43,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-23",3,2.14,87.19,,0,0.001,56.355,0.059,0.006,0.0137,960.577,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-24",2,1.4,54.74,,0,0.001,36.078,0.059,0.004,0.013,613.704,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-26",3,1.84,69.2,,0,0.001,45.382,0.059,0.005,0.0157,772.536,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-27",3,1.6,65.45,,0,0.001,41.577,0.059,0.004,0.016,709.265,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-06-30",3,1.88,78.4,,0,0.001,50.288,0.059,0.005,0.0113,856.54,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-03",2,1.15,45.75,,0,0.001,29.645,0.059,0.004,0.016,504.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-04",3,1.85,77.93,,0,0.001,50.001,0.059,0.005,0.0137,852.934,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-05",3,2.47,102.21,,0,0.001,66.62,0.059,0.006,0.0117,1134.192,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-08",2,1.38,54.79,,0,0.001,35.79,0.059,0.004,0.0115,610.703,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-09",3,1.67,69.53,,0,0.001,44.821,0.059,0.005,0.0167,763.423,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-10",2,1.2,46.95,,0,0.001,30.798,0.059,0.003,0.0125,524.817,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-11",1,0.5,6.5,,0,0.001,6.55,0.059,0.001,0.012,111.55,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-12",4,3.06,130.14,,0,0.001,82.442,0.059,0.008,0.0123,1404.712,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-18",2,1.35,54.31,,0,0.001,35.371,0.059,0.004,0.0135,603.645,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-23",3,2.37,88.85,,0,0.001,57.221,0.059,0.006,0.0117,975.161,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-24",2,1.17,45.71,,0,0.001,30.128,0.059,0.003,0.014,512.978,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-25",3,1.64,67.51,,0,0.001,44.495,0.059,0.005,0.016,758.205,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-26",4,3.15,135.24,,0,0.001,85.484,0.059,0.008,0.0115,1457.501,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-27",4,3.17,136.12,,0,0.001,86.166,0.059,0.009,0.012,1467.828,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-28",3,1.68,68.8,,0,0.001,44.194,0.059,0.005,0.0193,753.362,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-29",4,3.4,148.48,,0,0.001,93.668,0.059,0.009,0.0118,1597.608,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-30",5,4.16,178.92,,0.001,0.001,113.724,0.059,0.011,0.011,1936.568,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-03",2,1.18,45.3,,0,0.001,29.964,0.059,0.003,0.0125,510.858,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-06",3,1.2,46.81,,0,0.0007,30.272,0.0587,0.003,0.026,516.136,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-07",2,1.18,46.65,,0,0.001,31.407,0.059,0.004,0.0155,534.649,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-09",4,2.4,99.7,,0,0.001,64.272,0.059,0.006,0.014,1095.712,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-11",2,1.21,47.38,,0,0.001,31.078,0.059,0.003,0.0125,529.312,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-12",3,2.41,98.57,,0,0.001,63.751,0.059,0.006,0.0117,1085.607,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-13",5,3.77,153.46,,0.001,0.001,98.085,0.059,0.01,0.0118,1671.781,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-14",8,7.15,300.96,,0.001,0.001,190.003,0.059,0.017,0.0103,3237.95,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-15",7,5.88,249.72,,0.001,0.001,158.44,0.059,0.015,0.0116,2699.944,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-16",3,2.45,99.3,,0,0.001,64.216,0.059,0.006,0.012,1094.37,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-17",10,9.12,393.25,,0.001,0.001,247.979,0.059,0.023,0.0111,4223.833,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-18",12,10.98,481.52,,0.002,0.001,303.858,0.059,0.029,0.0113,5176.865,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-19",3,2.22,72.55,,0,0.001,47.669,0.059,0.004,0.0087,812.278,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-22",6,4.04,155.6,,0.001,0.001,101.388,0.059,0.01,0.0138,1726.13,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-23",3,1.24,47.35,,0,0.001,31.947,0.059,0.003,0.016,543.593,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-24",4,2.95,119.95,,0,0.001,76.828,0.059,0.008,0.016,1309.777,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-28",2,1.2,45.18,,0,0.001,29.559,0.059,0.003,0.012,503.064,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-03",2,1.25,48.39,,0,0.001,31.361,0.059,0.003,0.0115,534.083,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-05",4,2.9,121.04,,0,0.001,77.838,0.059,0.007,0.0113,1326.128,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-06",6,5.38,231.7,,0.001,0.001,145.93,0.059,0.013,0.0108,2486.902,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-11",4,2.41,95.81,,0,0.001,62.344,0.059,0.005,0.0133,1062.118,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-14",3,1.32,33.3,,0,0.001,23.602,0.059,0.007,0.0317,401.388,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-15",3,1.26,45.08,,0,0.001,31.242,0.059,0.003,0.0117,532.494,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-16",4,2.45,93.85,,0,0.001,61.048,0.059,0.006,0.0113,1041.097,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-17",3,1.25,44.71,,0,0.001,30.007,0.059,0.003,0.0137,511.873,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-18",3,1.68,69.16,,0,0.001,44.228,0.059,0.005,0.015,753.802,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-19",3,2.63,111.84,,0,0.001,72.438,0.059,0.007,0.0107,1234.378,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-21",1,1,44,,0,0.001,28.3,0.059,0.003,0.011,481.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-23",4,2.72,97.39,,0,0.001,65.361,0.059,0.006,0.0138,1114.022,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-27",2,1.15,45.16,,0,0.001,30.062,0.059,0.003,0.012,512.356,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-28",4,3.16,135.08,,0,0.001,85.596,0.059,0.009,0.0128,1458.996,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-29",5,3.73,150.77,,0.001,0.001,98.353,0.059,0.009,0.0118,1675.752,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-09-30",6,4.18,170.53,,0.001,0.001,108.745,0.059,0.011,0.0113,1852.996,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-01",6,4.23,174.36,,0.001,0.001,111.783,0.059,0.01,0.011,1905.04,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-02",2,1.08,37.08,,0,0.001,24.876,0.059,0.003,0.018,423.792,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-03",3,1.66,67.8,,0,0.001,45.564,0.059,0.005,0.017,776.11,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-04",4,2.33,92.8,,0,0.001,60.207,0.0593,0.006,0.0173,1026.593,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-05",5,4.11,184.94,,0.001,0.001,116.62,0.059,0.012,0.0122,1989.236,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-06",4,3.46,149.59,,0,0.001,93.207,0.059,0.01,0.013,1587.618,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-07",3,1.71,70.12,,0,0.001,45.038,0.059,0.005,0.0157,766.668,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-12",2,1.16,45.9,,0,0.001,30.044,0.059,0.004,0.017,511.23,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-13",4,2.7,115.38,,0,0.001,72.436,0.059,0.007,0.0145,1233.856,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-14",5,3.7,163.38,,0.001,0.001,100.946,0.059,0.009,0.0136,1719.328,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-15",6,5.15,230.39,,0.001,0.001,142.995,0.059,0.012,0.0103,2435.451,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-16",4,2.7,115.56,,0,0.001,72.54,0.059,0.007,0.0135,1236.006,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-17",2,1.18,46.98,,0,0.001,30.904,0.059,0.003,0.012,527.002,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-18",4,2.71,115.12,,0,0.001,72.319,0.059,0.007,0.0143,1232.694,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-19",4,3.2,140.04,,0,0.001,89.264,0.059,0.008,0.011,1520.348,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-20",3,2.23,94.23,,0,0.001,60.265,0.059,0.006,0.012,1027.024,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-21",4,2.91,125.51,,0,0.001,79.755,0.059,0.007,0.0113,1360.969,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-22",2,1.13,46.67,,0,0.001,30.389,0.059,0.003,0.012,518.045,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-23",3,1.41,59.21,,0,0.001,37.349,0.059,0.004,0.012,636.522,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-27",5,2.48,76.48,,0,0.0008,50.439,0.0598,0.006,0.0196,858.572,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-29",2,1.19,49.63,,0,0.001,32.137,0.059,0.003,0.0115,546.952,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-30",2,1.21,49.21,,0,0.001,32.918,0.059,0.004,0.0135,561.241,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-10-31",3,1.69,70.27,,0,0.001,45.068,0.059,0.005,0.016,768.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-01",3,2.13,91.05,,0,0.001,57.994,0.059,0.006,0.0117,987.914,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-02",4,3.39,147.95,,0,0.001,94.468,0.059,0.009,0.0115,1609.908,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-03",4,3.44,152.84,,0,0.001,95.564,0.059,0.009,0.0113,1629.68,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-04",9,6.89,301.58,,0.001,0.001,190.095,0.059,0.019,0.0128,3239.035,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-05",7,5.93,266.11,,0.001,0.001,164.003,0.059,0.015,0.0109,2795.394,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-06",4,2.93,127.45,,0,0.001,79.571,0.059,0.007,0.0108,1356.841,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-08",3,1.66,70.28,,0,0.001,44.933,0.059,0.004,0.015,766.089,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-09",7,5.27,228.39,,0.001,0.001,143.481,0.059,0.014,0.0126,2445.542,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-10",10,2.73,87.25,,0,0.0007,59.654,0.0586,0.017,0.0386,1015.523,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-11",10,5.9,240.59,,0.001,0.001,154.634,0.0589,0.016,0.0166,2636.058,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-12",5,3.62,156.83,,0.001,0.001,99.39,0.059,0.009,0.0106,1694.105,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-13",3,1.69,70.27,,0,0.001,45.103,0.059,0.005,0.0143,767.712,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-14",3,1.7,71.4,,0,0.001,45.745,0.059,0.005,0.0143,778.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-15",4,2.97,139.44,,0,0.001,87.02,0.059,0.01,0.0165,1482.655,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-16",3,1.7,71.72,,0,0.001,45.659,0.059,0.004,0.0143,778.363,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-17",6,4.11,173.35,,0.001,0.001,111.153,0.059,0.012,0.0128,1893.468,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-18",2,1.2,47.44,,0,0.001,31.942,0.059,0.003,0.01,543.494,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-19",3,1.93,81.5,,0,0.001,51.832,0.059,0.005,0.0107,882.146,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-20",3,1.65,71,,0,0.001,44.78,0.059,0.004,0.0127,762.445,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-21",5,2.85,118.95,,0,0.001,75.455,0.059,0.008,0.0162,1285.647,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-22",4,2.95,127.4,,0,0.001,80.48,0.059,0.007,0.0108,1371.665,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-24",6,2.85,122.52,,0,0.001,79.651,0.059,0.008,0.015,1357.175,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-25",3,1.69,70.1,,0,0.001,45.949,0.059,0.005,0.0147,783.338,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-27",2,1.19,47.52,,0,0.001,31.422,0.059,0.003,0.0125,535.327,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-29",3,1.95,81.87,,0,0.001,52.718,0.059,0.005,0.0117,897.184,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-11-30",3,2.13,96.25,,0,0.001,60.86,0.059,0.006,0.0107,1037.902,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-01",7,4.75,206.6,,0.001,0.001,130.689,0.059,0.013,0.0133,2227.186,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-02",8,5.68,251.97,,0.001,0.001,157.17,0.059,0.015,0.0154,2678.301,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-03",9,7.1,315.62,,0.001,0.001,199.055,0.059,0.017,0.0116,3389.255,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-04",9,8.11,365.06,,0.001,0.001,228.874,0.059,0.02,0.0102,3901.125,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-05",9,6.81,296.32,,0.001,0.001,187.639,0.059,0.018,0.0127,3196.417,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-06",6,4.69,205.1,,0.001,0.001,128.229,0.059,0.012,0.013,2187.28,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-07",7,6.28,278.8,,0.001,0.001,175.201,0.059,0.016,0.0109,2985.843,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-08",10,6.69,283.92,,0.001,0.001,179.633,0.059,0.018,0.0131,3060.338,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-09",8,6.41,277.97,,0.001,0.001,177.34,0.059,0.015,0.0101,3022.643,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-10",7,5.56,242.83,,0.001,0.001,152.967,0.059,0.015,0.0117,2607.995,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-11",7,4.71,216.05,,0.001,0.001,135.209,0.059,0.013,0.0151,2304.792,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-12",7,6.15,296.87,,0.001,0.001,182.816,0.059,0.016,0.0106,3115.627,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-13",5,3.49,142.72,,0,0.001,91.473,0.059,0.009,0.0124,1558.57,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-14",9,7.62,334,,0.001,0.001,210.446,0.059,0.021,0.012,3585.556,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-15",11,8.82,401.75,,0.001,0.001,249.846,0.059,0.023,0.012,4259.385,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-16",12,10.26,478.23,,0.002,0.001,294.724,0.059,0.027,0.0113,5022.752,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-17",1,0.4,12.8,,0,0.001,9.52,0.059,0.001,0.016,161.88,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-18",7,5.71,257.37,,0.001,0.001,161.886,0.059,0.015,0.011,2758.022,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-19",6,4.15,156.89,,0.001,0.001,99.193,0.059,0.008,0.0153,1691.365,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-20",3,1.45,44.19,,0,0.001,30.43,0.0587,0.003,0.0187,517.734,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-21",1,0.1,0,,0,0.001,0.65,0.059,0,0.045,11.08,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-24",2,1.24,49.87,,0,0.001,34.586,0.059,0.004,0.0125,589.262,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-27",2,1.19,27.14,,0,0.001,19.222,0.059,0.001,0.005,327.198,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-28",7,4.07,172.63,,0.001,0.001,109.657,0.059,0.011,0.0106,1866,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-29",4,2.13,89.36,,0,0.001,58.335,0.059,0.006,0.0123,994.715,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Panoche",55508,"GT-1",,"2020-12-31",3,1.72,68.32,,0,0.001,44.978,0.059,0.004,0.0123,766.584,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-03",2,1.2,45.9,,0,0.001,29.46,0.059,0.003,0.012,502.14,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-17",4,2.91,111.58,,0,0.001,71.2,0.059,0.007,0.0113,1211.636,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-25",2,1.27,47.45,,0,0.001,30.578,0.059,0.003,0.01,520.118,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-01",2,0.47,0,,0,0.001,2.135,0.059,0,0.02,36.179,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-02",2,0.33,0,,0,0.001,1.731,0.0585,0,0.024,29.586,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-03",2,0.87,30.24,,0,0.001,19.455,0.059,0.002,0.0175,330.837,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-05",3,1.22,45.75,,0,0.001,28.53,0.0587,0.004,0.0207,485.037,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-14",2,0.75,10.05,,0,0.001,7.259,0.0585,0.001,0.015,123.979,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-16",2,1.05,45,,0,0.001,27.36,0.0585,0.003,0.0225,466.45,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-17",1,0.17,1.7,,0,0.001,2.108,0.059,0,0.009,35.989,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-24",2,1.2,43.59,,0,0.001,28.359,0.059,0.003,0.013,482.251,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-25",10,7.6,348.67,,0.001,0.001,213.722,0.059,0.021,0.0119,3637.117,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-26",3,1.2,44.4,,0,0.001,28.355,0.059,0.003,0.0227,481.975,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-06",2,1.07,43.14,,0,0.001,27.05,0.059,0.002,0.0275,459.629,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-07",1,0.15,1.35,,0,0.001,1.86,0.059,0,0.009,31.605,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-14",3,1.22,43.7,,0,0.001,27.825,0.059,0.003,0.02,472.72,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-21",2,1.3,48.22,,0,0.001,30.426,0.059,0.003,0.0125,517.616,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-26",2,1.2,43.8,,0,0.001,27.408,0.059,0.003,0.0105,466.452,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-03",3,1.24,48.61,,0,0.001,29.573,0.059,0.003,0.025,503.484,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-04",2,1.22,46.68,,0,0.001,28.776,0.059,0.003,0.014,489.31,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-06",6,3.76,136.36,,0,0.001,83.884,0.059,0.009,0.013,1426.837,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-07",2,0.57,7.65,,0,0.001,5.437,0.059,0,0.008,92.304,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-14",2,1.23,45.93,,0,0.001,28.319,0.059,0.003,0.0135,481.967,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-16",2,1.22,46.12,,0,0.001,28.213,0.059,0.003,0.013,481.006,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-20",5,2.76,94.44,,0,0.001,59.31,0.059,0.006,0.0148,1008.307,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-21",5,2.68,110.94,,0,0.0008,66.933,0.0588,0.006,0.017,1138.819,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-22",7,2.88,103.21,,0,0.001,64.531,0.0589,0.006,0.0166,1099.982,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-23",2,1.22,44.26,,0,0.001,27.778,0.059,0.003,0.0115,471.982,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-24",9,5.47,212.13,,0.001,0.001,129.501,0.059,0.012,0.0109,2202.333,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-25",3,1.7,67.71,,0,0.001,41.253,0.059,0.004,0.0123,701.667,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-28",2,1.3,49.32,,0,0.001,30.794,0.059,0.003,0.0125,524.853,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-01",4,2.5,95.31,,0,0.001,58.696,0.059,0.006,0.0125,998.68,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-02",3,1.47,56.73,,0,0.001,35.142,0.059,0.004,0.014,597.726,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-05",4,3.29,138.97,,0,0.001,83.452,0.059,0.008,0.0113,1421.712,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-06",2,1.3,49.26,,0,0.001,30.55,0.059,0.003,0.0135,520.578,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-07",4,2.75,105.39,,0,0.001,64.333,0.059,0.007,0.0128,1096.01,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-08",6,3.67,149.35,,0,0.001,90.899,0.0588,0.009,0.0192,1546.214,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-09",3,1.7,66.37,,0,0.001,40.635,0.059,0.004,0.0107,692.659,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-11",3,1.95,79.59,,0,0.001,47.98,0.059,0.005,0.013,816.902,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-12",5,2.69,103.14,,0,0.001,62.77,0.059,0.006,0.0134,1068.476,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-16",5,3.54,149.39,,0,0.001,89.451,0.059,0.007,0.0102,1521.614,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-21",3,1.77,69.27,,0,0.001,42.156,0.059,0.003,0.0093,717.235,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-22",2,1.3,49.98,,0,0.001,30.736,0.059,0.003,0.01,524.202,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-23",3,1.32,49.06,,0,0.001,30.412,0.059,0.003,0.017,518.049,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-25",2,1.3,50.32,,0,0.001,31.166,0.059,0.003,0.014,529.942,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-26",5,3.76,166.18,,0.001,0.001,99.622,0.059,0.01,0.0112,1695.014,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-27",4,3,129.8,,0,0.001,78.272,0.059,0.008,0.0113,1332.372,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-28",3,1.27,47.97,,0,0.001,29.969,0.0587,0.003,0.0183,511.16,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-29",2,1.27,48.48,,0,0.001,30.021,0.059,0.003,0.0125,510.764,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-30",4,2.56,98.7,,0,0.001,60.42,0.059,0.006,0.0115,1027.478,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-08",8,4.96,189.5,,0.001,0.001,119.304,0.059,0.012,0.0118,2031.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-09",3,1.9,38.65,,0,0.0007,26.195,0.059,0.002,0.008,446.555,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-10",5,3.09,123.14,,0,0.001,75.776,0.059,0.008,0.0116,1289.24,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-16",5,2.56,96.75,,0,0.001,61.6,0.059,0.005,0.0142,1047.759,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-19",5,2.94,118.78,,0,0.001,73.85,0.059,0.007,0.0166,1257.178,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-22",3,2.27,93.12,,0,0.001,57.578,0.059,0.005,0.0097,980.942,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-23",3,1.97,79.47,,0,0.001,49.365,0.059,0.005,0.0113,841.336,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-24",5,2.79,109.19,,0,0.001,68.835,0.059,0.006,0.017,1172.511,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-26",3,1.97,80.63,,0,0.001,50.254,0.059,0.005,0.0103,854.826,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-27",1,0.33,0,,0,0.001,1.749,0.059,0,0.026,29.634,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-06-30",2,1.26,40.78,,0,0.001,25.868,0.059,0.002,0.008,440.812,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-01",5,2.58,99.02,,0,0.001,61.768,0.059,0.005,0.0168,1051.094,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-02",2,1.29,48.65,,0,0.001,30.792,0.059,0.003,0.0105,525.048,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-03",2,1.27,49.39,,0,0.001,30.565,0.059,0.003,0.012,521.016,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-04",3,1.77,72.27,,0,0.001,44.162,0.059,0.004,0.0097,751.807,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-05",4,3.4,146.4,,0,0.001,89.1,0.059,0.008,0.0113,1517.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-06",6,3.85,162.41,,0.001,0.001,99.088,0.059,0.01,0.013,1687.138,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-07",5,3.07,118.86,,0,0.001,74.336,0.059,0.008,0.0114,1265.335,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-08",2,1.32,49.92,,0,0.001,31.182,0.059,0.004,0.0135,531.81,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-09",6,4.81,198.2,,0.001,0.001,122.336,0.059,0.012,0.0122,2082.814,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-10",7,6.02,263.02,,0.001,0.001,159.96,0.059,0.014,0.0103,2723.124,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-11",7,5.75,250.91,,0.001,0.001,151.766,0.059,0.015,0.0111,2583.486,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-12",4,2.74,113.19,,0,0.001,69.438,0.059,0.006,0.0105,1181.739,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-14",14,12.22,539.91,,0.002,0.001,326.81,0.059,0.031,0.011,5562.729,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-17",3,1.27,47.64,,0,0.001,30.027,0.0587,0.003,0.025,512.036,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-21",9,5.77,224.99,,0.001,0.001,139.988,0.059,0.013,0.0156,2383.955,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-22",2,1.3,49.1,,0,0.001,30.766,0.059,0.002,0.0075,523.986,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-24",3,1.53,56.46,,0,0.001,35.423,0.059,0.003,0.0093,603.406,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-25",2,1.53,56.88,,0,0.001,36.009,0.059,0.003,0.011,612.846,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-26",4,3.28,137.34,,0,0.001,83.95,0.059,0.007,0.01,1428.033,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-27",3,1.75,35.47,,0,0.001,23.598,0.0587,0.001,0.007,400.988,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-28",2,0.34,0,,0,0.001,1.098,0.06,0,0.0335,18.44,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-29",6,2.59,60.13,,0,0.001,40.662,0.059,0.004,0.0162,691.537,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-30",8,4.6,179.35,,0.001,0.001,110.031,0.0589,0.009,0.0191,1871.392,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-07-31",6,4.59,151.54,,0,0.001,94.13,0.059,0.007,0.0097,1603.524,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-01",2,1.45,28.56,,0,0.001,18.945,0.059,0.001,0.006,321.945,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-05",1,0.12,0,,0,0.001,0.336,0.058,0,0.04,5.796,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-06",2,0.12,0,,0,0.0005,0.358,0.058,0,0.043,6.162,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-07",1,0.12,0,,0,0.001,0.348,0.058,0,0.042,5.964,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-08",3,1.31,25.33,,0,0.001,16.785,0.059,0.001,0.018,284.811,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-09",2,1.25,24.63,,0,0.001,16.588,0.059,0.001,0.0055,282.788,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-10",2,1.75,34.12,,0,0.001,22.134,0.059,0.001,0.005,376.019,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-11",2,1.25,23.38,,0,0.001,15.602,0.059,0.001,0.0115,265.544,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-12",2,1.35,24.98,,0,0.001,16.27,0.059,0.001,0.008,277.329,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-13",2,1.15,17.05,,0,0.001,11.905,0.059,0.002,0.017,202.42,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-14",8,7.29,152.84,,0,0.001,96.604,0.059,0.003,0.0041,1644.056,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-15",6,5.02,102.83,,0,0.001,66.528,0.059,0.002,0.0037,1130.176,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-17",8,7,150,,0,0.001,92.46,0.059,0.007,0.0085,1576.06,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-18",10,9.06,186.5,,0.001,0.001,116.186,0.059,0.009,0.0091,1973.014,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-19",10,8.42,179,,0.001,0.001,110.746,0.059,0.006,0.0092,1886.444,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-20",6,4.58,96.28,,0,0.001,60.99,0.059,0.002,0.005,1040.238,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-24",11,6.99,136.56,,0,0.001,88.485,0.0588,0.004,0.0112,1508.059,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-25",8,4.86,170.64,,0.001,0.001,106.94,0.0589,0.011,0.0136,1820.024,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-26",2,1.3,48.06,,0,0.001,30.286,0.059,0.003,0.01,516.02,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-27",7,5.32,218.78,,0.001,0.001,134.076,0.059,0.012,0.0104,2282.97,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-28",8,4.94,198.78,,0.001,0.001,122.495,0.059,0.012,0.0111,2085.817,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-29",2,1.3,49.3,,0,0.001,31.15,0.059,0.003,0.0105,529.42,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-08-31",9,7.65,164.79,,0.001,0.001,105.953,0.059,0.004,0.0043,1801.254,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-03",2,1.28,47.32,,0,0.001,29.239,0.059,0.003,0.0105,497.713,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-04",3,1.8,72.74,,0,0.001,44.514,0.059,0.004,0.01,757.272,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-05",9,8.48,279.12,,0.001,0.001,177.292,0.059,0.02,0.0119,3016.207,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-06",10,9.02,377.34,,0.001,0.001,226.553,0.059,0.018,0.0097,3855.178,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-09",2,1.52,53.8,,0,0.001,33.168,0.059,0.003,0.012,564.884,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-12",4,2.55,95.61,,0,0.001,58.782,0.059,0.005,0.0105,1001.427,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-13",3,2.04,82.82,,0,0.001,50.078,0.059,0.005,0.0113,851.824,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-15",3,1.3,49.2,,0,0.001,30.172,0.059,0.003,0.0177,513.392,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-16",5,3.06,116.79,,0,0.001,71.849,0.059,0.007,0.0112,1224.048,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-17",3,1.3,47.54,,0,0.001,29.596,0.059,0.003,0.0153,504.44,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-18",7,5.84,249.36,,0.001,0.001,148.891,0.059,0.015,0.0116,2532.541,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-19",6,4.07,138.28,,0,0.001,83.458,0.059,0.008,0.0098,1420.758,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-22",2,1.62,62.67,,0,0.001,38.454,0.059,0.004,0.0125,654.366,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-23",2,1.31,49.41,,0,0.001,30.156,0.059,0.003,0.012,513.344,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-28",3,2.05,87.11,,0,0.001,52.167,0.059,0.005,0.0113,889.046,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-09-30",5,3.05,121.69,,0,0.001,73.793,0.059,0.008,0.0132,1256.587,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-01",9,5.63,226.92,,0.001,0.001,137.091,0.059,0.013,0.0132,2333.324,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-02",5,4.05,168.71,,0.001,0.001,101.199,0.059,0.01,0.011,1722.788,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-04",2,1.28,47.24,,0,0.001,29.123,0.059,0.003,0.0105,496.405,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-05",4,2.78,120.58,,0,0.001,72.108,0.059,0.007,0.0105,1227.57,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-07",3,2.05,82.95,,0,0.001,50.38,0.059,0.005,0.011,858.684,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-10",3,1.3,49.9,,0,0.001,31.095,0.059,0.003,0.0163,528.721,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-12",4,2.25,93.91,,0,0.001,57.487,0.059,0.005,0.0163,980.009,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-13",2,1.77,71.58,,0,0.001,43.783,0.059,0.004,0.0115,746.237,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-14",3,2.29,93.92,,0,0.001,57.257,0.059,0.004,0.0093,974.116,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-15",4,3.27,138.79,,0,0.001,83.805,0.059,0.006,0.0088,1428.242,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-16",5,3.54,150.56,,0,0.001,91.098,0.059,0.008,0.0108,1549.658,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-19",11,10.15,449.63,,0.001,0.001,268.157,0.059,0.024,0.0105,4561.62,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-20",6,5.04,192.41,,0.001,0.001,116.449,0.059,0.01,0.0097,1980.499,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-21",3,2.09,83.5,,0,0.001,51.264,0.059,0.004,0.0097,872.967,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-26",3,1.27,48.5,,0,0.001,29.837,0.059,0.003,0.0203,508.245,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-27",2,1.29,49.56,,0,0.001,30.831,0.059,0.003,0.0115,524.604,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-29",2,1.29,49.56,,0,0.001,30.786,0.059,0.003,0.0125,524.868,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-01",2,1.27,47.87,,0,0.001,30.027,0.059,0.003,0.011,511.391,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-02",4,3.29,139.94,,0,0.001,84.489,0.059,0.007,0.0103,1438.553,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-04",3,2.52,104.88,,0,0.001,63.836,0.059,0.005,0.0097,1087.512,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-05",11,10.88,488.84,,0.001,0.001,289.804,0.059,0.024,0.0096,4933.684,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-06",8,6.48,277.16,,0.001,0.001,166.952,0.059,0.015,0.0106,2839.849,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-09",5,3.25,129.97,,0,0.001,78.815,0.059,0.007,0.0106,1340.588,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-10",3,2.04,82.62,,0,0.001,49.992,0.059,0.005,0.0113,851.154,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-11",5,2.54,96.03,,0,0.001,59.317,0.059,0.006,0.0138,1009.318,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-12",1,0.03,0,,0,0,0.042,0.058,0,0.008,0.72,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-14",2,1.3,48.06,,0,0.001,30.227,0.059,0.003,0.011,514.245,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-16",3,1.8,72.7,,0,0.001,44,0.059,0.004,0.0093,750.236,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-17",3,1.77,70.87,,0,0.001,43.285,0.059,0.004,0.0097,737.772,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-19",2,1.29,49.56,,0,0.001,30.657,0.059,0.003,0.011,521.379,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-20",3,1.8,70.64,,0,0.001,43.616,0.059,0.004,0.0113,742.002,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-21",3,1.3,49.69,,0,0.001,30.634,0.059,0.003,0.0213,520.673,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-22",3,1.8,73.07,,0,0.001,44.279,0.059,0.005,0.0123,753.826,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-23",4,2.58,99.8,,0,0.001,61.23,0.059,0.005,0.0105,1042.803,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-24",2,1.29,47.68,,0,0.001,29.995,0.059,0.003,0.0115,510.694,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-29",3,1.8,71.27,,0,0.001,43.462,0.059,0.004,0.0127,739.749,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-04",3,1.33,29,,0,0.001,32.904,0.059,0.005,0.027,559.866,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-05",6,2.66,44.35,,0,0.001,54.186,0.059,0.007,0.0218,922.884,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-07",4,1.83,74.04,,0,0.001,44.639,0.059,0.005,0.028,758.868,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-08",1,0.12,2.28,,0,0.001,1.44,0.059,0.001,0.052,24.468,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-09",7,3.85,149.84,,0,0.001,91.451,0.059,0.01,0.0216,1556.938,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-10",6,4.58,188.82,,0.001,0.001,113.145,0.059,0.012,0.0125,1926.635,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-11",2,1.29,48.97,,0,0.001,30.047,0.059,0.004,0.014,511.846,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-14",3,2.27,94.32,,0,0.001,57.21,0.059,0.006,0.013,974.32,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-15",4,2.59,98.64,,0,0.001,60.709,0.059,0.007,0.014,1033.622,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-16",3,1.8,71.27,,0,0.001,43.391,0.059,0.005,0.0177,739.151,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-17",5,4.37,186.95,,0.001,0.001,111.755,0.059,0.01,0.0116,1902.072,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-18",5,4.67,99.39,,0,0.001,61.905,0.059,0.005,0.0106,1054.355,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-25",3,1.27,48.3,,0,0.001,29.944,0.059,0.004,0.034,510.698,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Border",55510,"GT-1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-09",3,2.21,44.17,,0,0.001,29.129,0.058,0.003,0.012,498.889,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-17",2,0.35,3.85,,0,0.001,3.06,0.058,0.001,0.0495,52.555,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-22",8,6.85,141.89,,0,0.001,93.416,0.0583,0.008,0.0111,1598.768,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-24",1,0.13,0,,0,0.001,0.39,0.059,0,0.045,6.578,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-28",1,0.25,0,,0,0.001,1.5,0.059,0,0.028,25.625,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-14",3,1.43,26.25,,0,0.001,18.249,0.0587,0.003,0.0163,311.182,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-25",3,2.25,85.18,,0,0.001,55.017,0.0587,0.009,0.0173,940.344,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-26",3,2.25,84.86,,0,0.001,55.13,0.0583,0.007,0.0147,942.609,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-13",3,0.83,0,,0,0.001,3.325,0.059,0.001,0.026,56.473,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-14",2,0.31,0.28,,0,0.001,1.325,0.058,0,0.028,22.885,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-07",4,0.44,0,,0,0.0008,1.489,0.059,0,0.028,25.302,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-08",1,0.15,0,,0,0.001,0.435,0.059,0,0.028,7.41,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-09",3,2.19,46.38,,0,0.001,30.65,0.0587,0.002,0.009,523.906,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-24",7,5.06,105.72,,0,0.001,70.502,0.0587,0.006,0.0104,1203.938,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-25",1,0.53,6.89,,0,0.001,5.247,0.058,0.002,0.036,89.835,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-04-30",6,5.32,220.32,,0.001,0.001,140.684,0.0587,0.031,0.031,2404.404,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-06",1,0.2,0,,0,0.001,0.94,0.058,0,0.026,16.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-26",3,2.11,76.54,,0,0.001,50.129,0.0587,0.006,0.019,856.584,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-10",3,2.13,40.79,,0,0.001,27.453,0.0583,0.004,0.016,469.653,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-07",3,2.15,79.37,,0,0.001,51.61,0.0587,0.006,0.0137,881.034,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-11",4,2.18,84.43,,0,0.001,54.319,0.0583,0.006,0.0155,928.404,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-16",6,5.27,207.54,,0.001,0.001,132.495,0.0588,0.014,0.0122,2262.776,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-29",4,2.98,118.63,,0,0.001,75.836,0.0588,0.008,0.013,1294.927,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-07-31",3,1.72,66.44,,0,0.001,42.871,0.0587,0.006,0.0153,733.083,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-12",4,2.73,106.68,,0,0.001,68.498,0.0588,0.009,0.0188,1169.559,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-13",7,5.77,155.89,,0.001,0.001,102.144,0.0586,0.009,0.0103,1745.021,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-14",10,8.93,353.32,,0.001,0.001,226.194,0.0586,0.021,0.0118,3865.016,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-15",6,4.77,187.18,,0.001,0.001,120.7,0.0587,0.012,0.0127,2061.845,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-16",3,2.07,81.51,,0,0.001,52.343,0.0587,0.005,0.014,893.709,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-17",3,2.1,81.12,,0,0.001,52.554,0.0583,0.007,0.016,898.132,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-18",11,10.3,372.74,,0.001,0.001,242.674,0.0584,0.022,0.0111,4149.799,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-19",5,4.75,186.09,,0.001,0.001,119.379,0.0586,0.012,0.0118,2039.584,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-20",3,2.74,103.84,,0,0.001,67.702,0.059,0.008,0.0133,1156.164,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-24",7,5.75,222.11,,0.001,0.001,143.664,0.0584,0.014,0.0126,2455.051,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-25",5,3.78,143.22,,0,0.001,92.679,0.0586,0.009,0.0132,1583.434,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-26",2,0.35,3.64,,0,0.001,2.996,0.058,0.001,0.0145,51.17,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-28",4,2.25,82.52,,0,0.001,53.769,0.0585,0.005,0.0163,919.665,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-03",4,3.29,125.54,,0,0.001,82.311,0.0585,0.009,0.013,1407.723,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-04",3,2.25,80.47,,0,0.001,53.596,0.0583,0.006,0.0127,916.619,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-05",8,7.15,278.05,,0.001,0.001,180.646,0.0586,0.017,0.0111,3087.424,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-06",12,11.23,446.55,,0.001,0.001,287.577,0.0584,0.027,0.0112,4915.002,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-11",5,3.74,146.11,,0,0.001,93.068,0.0588,0.009,0.01,1590.516,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-19",4,3.29,118.84,,0,0.001,76.167,0.0585,0.008,0.0148,1301.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-09-30",5,2.92,97.79,,0,0.001,63.769,0.0588,0.009,0.0158,1089.605,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-01",6,5.43,144.64,,0,0.001,95.436,0.0585,0.008,0.0102,1631.607,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-04",3,2.28,86.97,,0,0.001,55.635,0.058,0.008,0.0153,952.571,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-05",12,10.4,400.95,,0.001,0.001,255.876,0.0588,0.025,0.0113,4370.837,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-06",11,10.21,410.36,,0.001,0.001,261.723,0.0582,0.026,0.0116,4475.372,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-13",3,2.3,84.81,,0,0.001,55.443,0.0587,0.007,0.015,947.588,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-14",3,2.25,82.96,,0,0.001,54.507,0.0583,0.007,0.014,931.442,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-15",3,2.41,89.69,,0,0.001,58.69,0.0583,0.006,0.0127,1003.005,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-16",3,2.28,83.52,,0,0.001,55.174,0.0587,0.006,0.0157,943.701,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-02",3,2.17,80.91,,0,0.001,52.554,0.0583,0.006,0.014,898.17,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-04",3,2.25,45.75,,0,0.001,30.715,0.059,0.002,0.011,524.219,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-05",6,3.4,109.5,,0,0.001,73.253,0.0587,0.01,0.0222,1251.941,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-08",3,1.56,36.26,,0,0.001,26.068,0.0583,0.004,0.0277,445.496,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-09",3,2.29,87.18,,0,0.001,56.247,0.059,0.007,0.0143,960.48,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-10",3,2.28,87.74,,0,0.001,56.468,0.0587,0.007,0.016,964.812,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-17",9,8.2,336.64,,0.001,0.001,213.388,0.0586,0.022,0.0122,3646.172,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-19",2,0.77,14,,0,0.001,12.327,0.058,0.004,0.036,210.833,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-04",4,0.94,26.78,,0,0.001,18.727,0.059,0.002,0.04,319.574,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-15",3,0.6,0.6,,0,0.001,2.119,0.0587,0,0.029,36.139,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cuyamaca Peak Energy",55512,"GT-1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-08",6,2.99,112.9,,0,0.001,70.953,0.0583,0.012,0.0303,1213.302,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-14",2,1.25,45.8,,0,0.001,29.155,0.0585,0.006,0.0205,498.506,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-17",4,2.91,111.23,,0,0.001,69.559,0.0588,0.009,0.015,1188.269,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-01",2,1.29,48.83,,0,0.001,30.698,0.058,0.005,0.0225,525.146,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-03",2,1.22,44.6,,0,0.001,28.298,0.058,0.004,0.0145,484.272,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-04",2,1.29,46.53,,0,0.001,29.619,0.0585,0.005,0.0175,506.139,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-05",3,1.22,45.53,,0,0.001,28.621,0.0583,0.003,0.024,489.894,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-19",2,1.29,47.01,,0,0.001,30.052,0.0585,0.005,0.018,513.563,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-26",2,1.22,44.76,,0,0.001,28.398,0.0585,0.004,0.025,485.85,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-21",2,1.32,48.6,,0,0.001,31.086,0.0585,0.005,0.0165,530.694,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-03",3,1.24,47.05,,0,0.001,29.484,0.0583,0.005,0.0303,504.058,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-06",6,3.76,141.68,,0,0.001,87.992,0.0585,0.014,0.0188,1503.971,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-14",2,1.25,46.82,,0,0.001,29.022,0.0585,0.005,0.0215,496.398,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-16",2,1.22,45.57,,0,0.001,28.957,0.0585,0.005,0.02,494.879,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-21",5,2.52,100.9,,0,0.001,62.255,0.0584,0.009,0.024,1064.353,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-22",7,2.67,58.41,,0,0.001,39.307,0.058,0.006,0.02,672.744,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-23",4,1.36,44.26,,0,0.0008,28.416,0.0575,0.004,0.0208,486.126,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-24",9,5.48,199.51,,0.001,0.001,125.081,0.0581,0.017,0.016,2139.283,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-25",3,1.8,70.54,,0,0.001,43.832,0.0583,0.006,0.0173,749.934,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-28",2,1.23,44.55,,0,0.001,28.407,0.059,0.007,0.0235,484.489,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-01",4,2.52,92.99,,0,0.001,58.999,0.0583,0.008,0.016,1008.809,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-02",3,1.49,57.56,,0,0.001,36.186,0.0587,0.006,0.024,618.583,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-05",4,3.27,134.92,,0,0.001,83.384,0.0583,0.01,0.0148,1425.43,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-06",2,1.32,48.72,,0,0.001,31.032,0.0585,0.005,0.019,530.052,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-07",2,1.29,49.2,,0,0.001,30.846,0.058,0.005,0.027,527.662,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-08",5,3.17,121.65,,0,0.001,76.251,0.0588,0.012,0.0182,1302.556,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-09",3,1.97,78.47,,0,0.001,48.093,0.059,0.006,0.015,821.078,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-11",2,1.22,45.18,,0,0.001,28.24,0.058,0.003,0.0175,483.104,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-12",3,1.24,45.6,,0,0.001,28.94,0.059,0.004,0.0217,494.079,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-16",5,3.55,147,,0,0.001,90.923,0.0588,0.01,0.0152,1553.791,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-21",3,1.79,66.95,,0,0.001,42.282,0.0583,0.004,0.0117,722.847,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-22",2,1.3,50.15,,0,0.001,31.521,0.0585,0.003,0.0135,538.681,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-23",2,1.32,49.92,,0,0.001,31.71,0.058,0.005,0.0165,542.292,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-25",2,1.27,48.79,,0,0.001,31.108,0.0585,0.005,0.0205,531.919,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-26",5,3.77,162.27,,0.001,0.001,100.244,0.0584,0.011,0.013,1714.033,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-27",4,3,128.64,,0,0.001,79.508,0.0588,0.009,0.0128,1359.262,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-28",3,1.29,48.02,,0,0.001,30.555,0.0587,0.003,0.018,522.156,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-30",2,1.29,49.56,,0,0.001,31.515,0.059,0.004,0.0125,538.125,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-08",5,3.25,129.35,,0,0.001,82.51,0.0588,0.011,0.0178,1408.885,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-09",7,3.9,147.3,,0,0.001,94.135,0.0586,0.012,0.0154,1609.66,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-10",3,1.3,49.32,,0,0.001,31.576,0.0587,0.004,0.021,539.456,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-11",3,1.27,48.17,,0,0.001,31.023,0.0583,0.004,0.019,529.759,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-16",2,1.3,47.88,,0,0.001,31.062,0.0585,0.004,0.0195,530.946,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-19",5,2.96,116.64,,0,0.001,74.82,0.0584,0.009,0.0176,1280.062,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-22",3,2.27,92.52,,0,0.001,58.613,0.0587,0.007,0.0143,1001.634,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-23",3,2.02,81.42,,0,0.001,51.816,0.058,0.006,0.0147,886.474,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-24",5,3.06,117.52,,0,0.001,75.824,0.0588,0.009,0.0134,1295.222,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-26",3,1.92,77.64,,0,0.001,49.088,0.0587,0.006,0.014,838.924,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-27",3,1.69,66.12,,0,0.001,42.196,0.0587,0.006,0.0173,721.05,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-06-30",2,1.3,49.1,,0,0.001,31.864,0.058,0.005,0.017,545.022,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-01",2,1.31,49.19,,0,0.001,31.585,0.0585,0.004,0.0155,539.345,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-02",2,1.3,47.88,,0,0.001,31.116,0.0585,0.004,0.0155,531.518,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-03",2,1.27,48.12,,0,0.001,30.967,0.0585,0.004,0.0155,529.244,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-04",3,1.76,73.34,,0,0.001,46.046,0.059,0.005,0.013,785.94,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-05",4,2.9,120.5,,0,0.001,75.25,0.0585,0.009,0.0148,1287.13,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-06",6,3.8,150.22,,0,0.001,94.865,0.058,0.011,0.0157,1623.335,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-07",3,1.77,71.36,,0,0.001,44.864,0.0583,0.006,0.0137,766.755,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-08",2,1.32,49.92,,0,0.001,31.932,0.0585,0.005,0.016,545.418,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-09",6,4.77,196.14,,0.001,0.001,123.075,0.0587,0.015,0.0172,2102.232,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-10",7,6.02,264.84,,0.001,0.001,163.198,0.0584,0.019,0.014,2790.396,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-11",7,5.69,248.15,,0.001,0.001,153.456,0.0587,0.016,0.013,2622.218,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-12",4,2.74,113.59,,0,0.001,70.635,0.0585,0.009,0.0148,1206.965,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-14",3,1.28,48.02,,0,0.001,30.994,0.0587,0.003,0.02,529.856,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-15",2,1.29,48.69,,0,0.001,31.038,0.058,0.004,0.0145,530.787,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-20",5,3.77,158.86,,0.001,0.001,98.767,0.0586,0.011,0.0156,1687.091,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-21",3,1.27,48.33,,0,0.001,30.801,0.0583,0.004,0.0163,526.216,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-24",2,1.52,59.9,,0,0.001,37.938,0.059,0.008,0.024,648.442,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-25",2,1.55,60.16,,0,0.001,38.222,0.059,0.007,0.02,652.651,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-26",4,3.25,127.2,,0,0.001,80.855,0.0588,0.011,0.0158,1381.275,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-27",5,4.09,143.46,,0,0.001,92.046,0.0586,0.01,0.0128,1573.892,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-28",3,1.8,70.27,,0,0.001,44.751,0.0583,0.007,0.0177,765.449,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-29",4,3.12,124.56,,0,0.001,78.83,0.059,0.011,0.0163,1346.54,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-30",5,4.2,164.8,,0.001,0.001,104.39,0.0586,0.011,0.0134,1784.44,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-07-31",5,4.32,168.8,,0.001,0.001,106.832,0.0586,0.011,0.012,1826.02,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-01",3,1.95,39.1,,0,0.001,25.883,0.0583,0.003,0.0123,442.465,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-09",4,2.55,88.73,,0,0.001,56.878,0.0585,0.008,0.017,972.73,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-10",2,1.79,67.1,,0,0.001,43.144,0.059,0.006,0.016,737.038,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-11",2,1.3,47.5,,0,0.001,30.98,0.059,0.006,0.03,528.756,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-12",4,3.55,143.35,,0,0.001,90.243,0.058,0.01,0.0143,1543.763,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-13",7,5.78,229.99,,0.001,0.001,144.9,0.0583,0.015,0.0127,2478.322,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-14",8,7.3,293.79,,0.001,0.001,185.835,0.0586,0.02,0.013,3173.852,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-15",6,5.02,202.26,,0.001,0.001,129.109,0.0588,0.015,0.0133,2205.231,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-16",3,1.78,64.73,,0,0.001,41.832,0.058,0.005,0.0133,715.629,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-17",8,7.03,281.88,,0.001,0.001,178.987,0.0584,0.019,0.0128,3059.865,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-18",9,8.32,333.06,,0.001,0.001,211.95,0.0584,0.021,0.0114,3622.098,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-19",9,7.83,184.71,,0.001,0.001,118.079,0.0586,0.012,0.0112,2018.137,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-20",6,4.57,155.67,,0.001,0.001,100.87,0.0583,0.009,0.0102,1723.742,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-24",7,6.02,129.36,,0,0.001,83.927,0.0587,0.007,0.0094,1434.225,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-25",2,1.32,24.39,,0,0.001,16.423,0.0585,0.002,0.016,281.114,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-27",4,2.75,64.2,,0,0.001,42.615,0.0585,0.005,0.0125,727.805,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-28",4,2.87,89.52,,0,0.001,57.094,0.0588,0.006,0.015,975.638,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-29",2,1.23,44.8,,0,0.001,28.944,0.059,0.004,0.0135,494.145,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-08-31",1,0.25,0,,0,0.001,0.775,0.058,0,0.039,13.25,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-03",3,2.03,76.28,,0,0.001,48.687,0.0583,0.006,0.0147,831.997,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-04",3,1.79,69.97,,0,0.001,44.47,0.0583,0.005,0.0137,760.251,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-05",8,7.56,317.98,,0.001,0.001,197.84,0.0586,0.025,0.0154,3379.852,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-06",10,9.02,370.7,,0.001,0.001,230.571,0.0583,0.028,0.0145,3941.888,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-12",2,1.29,45.88,,0,0.001,29.223,0.0585,0.004,0.0215,499.188,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-13",3,2.05,78.91,,0,0.001,49.163,0.058,0.006,0.0137,840.739,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-14",6,5.24,210.02,,0.001,0.001,129.824,0.0587,0.017,0.0167,2219.278,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-15",12,10.97,442.13,,0.001,0.001,274.589,0.0584,0.031,0.0141,4693.245,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-16",7,4.62,165.42,,0.001,0.001,105.229,0.0586,0.015,0.0189,1798.998,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-17",2,1.31,47.33,,0,0.001,30.08,0.059,0.005,0.0225,513.401,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-18",6,4.1,144.74,,0,0.001,92.085,0.0587,0.015,0.0188,1573.551,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-19",4,2.54,99.17,,0,0.001,61.355,0.0585,0.007,0.017,1047.781,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-20",3,1.8,68.98,,0,0.001,42.852,0.0583,0.006,0.017,733.149,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-21",3,1.55,56.83,,0,0.001,36.052,0.0587,0.005,0.0217,616.338,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-22",2,1.31,46.48,,0,0.001,29.422,0.059,0.004,0.017,502.668,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-23",7,5.02,138.99,,0,0.001,88.625,0.0584,0.012,0.017,1514.612,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-24",1,0.58,13.92,,0,0.001,9.338,0.058,0.002,0.027,160.08,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-25",7,4.77,118.22,,0,0.0009,74.476,0.0586,0.008,0.018,1273.24,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-28",5,4.93,211.2,,0.001,0.001,128.685,0.0586,0.016,0.0144,2199.949,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-29",12,9.47,396.29,,0.001,0.001,242.908,0.0587,0.027,0.0146,4149.763,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-09-30",2,1.79,71.55,,0,0.001,44.377,0.0585,0.006,0.015,758.014,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-01",3,2.8,116.01,,0,0.001,71.649,0.0587,0.007,0.0123,1223.755,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-02",3,1.79,71.05,,0,0.001,44.108,0.0587,0.006,0.019,753.67,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-04",2,1.28,46.89,,0,0.001,29.879,0.0585,0.004,0.0155,510.701,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-05",3,1.54,59.82,,0,0.001,37.79,0.0583,0.004,0.019,645.247,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-06",2,1.31,48.53,,0,0.001,31.071,0.059,0.004,0.014,530.829,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-07",2,1.3,48.66,,0,0.001,31.176,0.059,0.004,0.017,532.246,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-12",4,2.27,93.8,,0,0.001,58.613,0.0583,0.007,0.0228,1002.899,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-13",2,1.53,59.67,,0,0.001,37.584,0.059,0.005,0.0145,642.108,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-14",3,2.27,93.72,,0,0.001,58.766,0.059,0.007,0.014,1003.841,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-15",4,3.27,138.19,,0,0.001,85.46,0.059,0.009,0.0128,1459.292,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-19",5,3.33,132.65,,0,0.001,82.934,0.0584,0.01,0.017,1416.788,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-20",3,2.07,84.34,,0,0.001,52.585,0.0583,0.006,0.0157,898.975,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-21",2,1.3,48.85,,0,0.001,31.242,0.059,0.004,0.0155,533.232,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-22",9,7.82,347.67,,0.001,0.001,211.639,0.0583,0.021,0.0126,3616.96,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-26",3,1.27,48.1,,0,0.001,30.388,0.0583,0.004,0.0307,519.962,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-27",2,1.3,50.4,,0,0.001,31.722,0.058,0.004,0.014,543.002,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-29",2,1.29,51.3,,0,0.001,31.995,0.0585,0.004,0.0145,546.81,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-01",2,1.27,47.87,,0,0.001,30.45,0.0585,0.004,0.0155,520.57,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-02",3,2.52,104.28,,0,0.001,64.72,0.0583,0.006,0.012,1106.232,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-04",4,3.02,127.02,,0,0.001,79.052,0.0588,0.008,0.0128,1350.21,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-05",6,4.8,209.96,,0.001,0.001,128.186,0.0587,0.013,0.0145,2191.32,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-06",4,3.03,127.33,,0,0.001,78.559,0.0583,0.008,0.0133,1343.526,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-08",2,1.31,48.53,,0,0.001,30.85,0.0585,0.004,0.0145,527.332,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-09",3,1.78,62.72,,0,0.001,39.938,0.058,0.006,0.0223,683.436,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-10",6,3.31,125.55,,0,0.001,78.932,0.0588,0.009,0.0235,1347.502,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-11",2,1.27,45.75,,0,0.001,29.39,0.0585,0.004,0.0135,502.167,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-12",1,0.03,0,,0,0,0.123,0.058,0,0.079,2.103,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-14",2,1.3,47.39,,0,0.001,30.223,0.0585,0.003,0.013,516.304,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-16",3,1.82,71.57,,0,0.001,44.698,0.059,0.004,0.016,763.469,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-17",3,1.77,70.1,,0,0.001,43.836,0.0587,0.005,0.0167,748.703,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-19",3,1.3,49.38,,0,0.001,31.241,0.0587,0.003,0.024,533.426,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-20",3,1.79,70.88,,0,0.001,44.439,0.059,0.006,0.018,758.601,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-21",3,1.3,48.65,,0,0.001,31.15,0.058,0.004,0.0283,532.911,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-22",3,1.8,72.07,,0,0.001,45.216,0.0583,0.005,0.0167,772.76,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-23",4,2.58,98.56,,0,0.001,62.292,0.0588,0.007,0.0138,1064.109,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-24",2,1.55,58.9,,0,0.001,37.82,0.059,0.004,0.013,645.482,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-29",3,1.8,71.27,,0,0.001,44.482,0.0587,0.005,0.0177,760.35,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-11-30",3,1.8,71.9,,0,0.001,44.9,0.0587,0.005,0.0173,767.451,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-01",3,1.8,72.07,,0,0.001,45.245,0.059,0.005,0.017,772.347,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-02",2,1.47,57.33,,0,0.001,36.181,0.058,0.004,0.014,618.991,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-04",1,0.03,0,,0,0.001,0.111,0.058,0,0.067,1.899,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-05",2,1.3,50.62,,0,0.001,31.507,0.059,0.005,0.017,537.88,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-11",3,2.11,79.2,,0,0.001,49.661,0.0587,0.007,0.0253,848.044,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-12",2,1.3,48.69,,0,0.001,31.133,0.0585,0.004,0.0135,532.003,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-14",3,2.29,93.92,,0,0.001,58.049,0.0587,0.007,0.0153,991.961,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-15",4,2.52,93.37,,0,0.001,59.501,0.0585,0.007,0.0143,1017.341,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-16",4,3.54,151.68,,0,0.001,92.444,0.0583,0.009,0.0118,1581.192,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-21",2,1.2,45,,0,0.001,28.254,0.059,0.004,0.016,482.424,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-25",2,1.29,47.82,,0,0.001,30.261,0.0585,0.005,0.017,517.485,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","CalPeak Power - Enterprise",55513,"GT-1",,"2020-12-31",2,1.41,54.1,,0,0.001,33.555,0.0585,0.005,0.018,573.767,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-01",10,9.18,1905.16,,0.004,0.001,834.712,0.059,0.101,0.0238,14043.394,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-02",10,9.3,2083.9,,0.005,0.001,903.23,0.059,0.075,0.0124,15197.15,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-03",24,24,5969,,0.013,0.001,2547.5,0.059,0.165,0.0077,42869.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-04",12,10.99,2549.71,,0.006,0.001,1110.316,0.059,0.1,0.0165,18684.422,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-05",12,10.98,2477.4,,0.005,0.001,1080.154,0.059,0.09,0.0146,18174.876,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-06",24,24,5796,,0.013,0.001,2480.2,0.059,0.163,0.0078,41730.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-07",24,24,5809,,0.013,0.001,2497.6,0.059,0.166,0.0079,42028.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-08",1,0.32,29.76,,0,0.001,17.056,0.059,0.004,0.026,286.816,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-10",7,6.67,1383.82,,0.003,0.001,610.231,0.059,0.097,0.0314,10269.307,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-11",4,3.53,603.83,,0.001,0.001,265.587,0.059,0.022,0.0118,4467.961,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-13",10,9.15,2044.15,,0.005,0.001,898.38,0.059,0.119,0.0253,15116.815,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-14",24,24,5060,,0.011,0.001,2193.5,0.059,0.149,0.0081,36910,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-15",24,24,5809,,0.013,0.001,2491.7,0.059,0.168,0.008,41927.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-16",24,23.32,5740.52,,0.012,0.001,2463.82,0.059,0.171,0.0089,41457.92,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-17",18,17.68,4002.04,,0.009,0.001,1746.832,0.059,0.12,0.0089,29390.372,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-18",18,16.98,4197.82,,0.009,0.001,1824.85,0.059,0.133,0.0108,30709.058,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-19",18,17,4184.04,,0.009,0.001,1809.892,0.059,0.131,0.0106,30457.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-20",24,24,6220,,0.013,0.001,2657,0.059,0.18,0.008,44707.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-21",18,16.98,4123.7,,0.009,0.001,1791.114,0.059,0.128,0.0103,30133.47,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-22",10,9.04,2121.28,,0.005,0.001,932.956,0.059,0.084,0.0161,15698.824,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-23",24,24,5534,,0.012,0.001,2400.6,0.059,0.164,0.0081,40399.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-24",18,17.08,4186.58,,0.009,0.001,1816.616,0.059,0.138,0.0111,30570.887,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-25",12,11,2527.16,,0.006,0.001,1111.104,0.059,0.087,0.0129,18695.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-26",12,11.06,2594.72,,0.006,0.001,1137.488,0.059,0.101,0.0148,19141.26,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-27",18,16.92,3746.19,,0.008,0.001,1644.46,0.059,0.118,0.0104,27672.579,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-28",10,8.92,2082.76,,0.005,0.001,914.752,0.059,0.077,0.0155,15392.28,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-29",10,8.97,2118.76,,0.005,0.001,932.943,0.059,0.082,0.016,15698.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-30",24,24,5548,,0.012,0.001,2399.9,0.059,0.16,0.0079,40378.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-01-31",24,24,5519,,0.012,0.001,2391.9,0.059,0.161,0.008,40249.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-01",18,16.89,4167.78,,0.009,0.001,1794.717,0.059,0.13,0.011,30197.114,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-02",18,16.97,4172.76,,0.009,0.001,1800.81,0.059,0.131,0.0107,30299.641,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-03",24,24,5591,,0.012,0.001,2397.8,0.059,0.161,0.008,40348.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-04",24,24,5600,,0.012,0.001,2421.1,0.059,0.163,0.008,40740.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-05",18,17.03,4230.45,,0.009,0.001,1836.543,0.059,0.144,0.0121,30903.957,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-06",18,16.99,3870.27,,0.009,0.001,1694.344,0.059,0.128,0.0119,28510.642,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-07",18,16.99,4003.61,,0.009,0.001,1749.615,0.059,0.128,0.0107,29440.077,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-08",18,16.95,3994.29,,0.009,0.001,1730.767,0.059,0.124,0.0105,29123.583,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-09",12,10.99,2457.35,,0.005,0.001,1078.529,0.059,0.088,0.0137,18150.585,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-10",18,16.89,4117.31,,0.009,0.001,1799.816,0.059,0.128,0.0108,30285.962,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-11",18,16.9,4163.28,,0.009,0.001,1807.934,0.059,0.13,0.0105,30420.524,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-12",18,16.96,4158.1,,0.009,0.001,1799.366,0.059,0.128,0.0104,30272.982,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-13",18,16.96,4117.7,,0.009,0.001,1783.718,0.059,0.134,0.0119,30012.256,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-14",18,16.77,4139.08,,0.009,0.001,1787.263,0.0591,0.134,0.0116,30074.344,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-15",18,17.06,4227.68,,0.009,0.001,1824.33,0.059,0.131,0.0099,30698.814,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-16",17,16.03,3787.88,,0.008,0.001,1642.523,0.059,0.121,0.0107,27637.402,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-17",24,24,5492,,0.012,0.001,2375.8,0.059,0.159,0.008,39977,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-18",18,17,4162.23,,0.009,0.001,1800.53,0.059,0.13,0.0104,30297.878,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-19",24,24,5553,,0.012,0.001,2399.4,0.059,0.161,0.008,40372.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-20",18,17.05,4120.48,,0.009,0.001,1803.584,0.059,0.134,0.0106,30348.064,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-21",24,24,5467,,0.012,0.001,2353.4,0.059,0.158,0.008,39603.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-22",18,17,4130.38,,0.009,0.001,1788.821,0.059,0.13,0.0105,30103.032,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-23",12,11.02,2506.5,,0.006,0.001,1095.75,0.059,0.099,0.0157,18440.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-24",18,17.04,3886.94,,0.009,0.001,1686.271,0.059,0.121,0.0099,28374.701,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-25",18,17.03,4144.02,,0.009,0.001,1793.122,0.059,0.129,0.0102,30173.931,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-26",18,16.86,4115.7,,0.009,0.001,1783.242,0.059,0.127,0.0103,30006.144,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-27",18,16.86,4079.3,,0.009,0.001,1761.262,0.059,0.125,0.0104,29638.15,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-28",24,24,5877,,0.013,0.001,2497.9,0.059,0.169,0.008,42031.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-02-29",17,15.95,3739.02,,0.008,0.001,1615.228,0.059,0.118,0.0112,27182.61,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-01",17,15.96,3917.02,,0.009,0.001,1712.334,0.059,0.12,0.0101,28815.672,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-02",24,24,5587,,0.012,0.001,2413.5,0.059,0.163,0.008,40609.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-03",19,17.55,4211.1,,0.009,0.001,1845.621,0.059,0.133,0.0109,31056.885,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-04",18,16.95,4186.35,,0.009,0.001,1818.601,0.059,0.131,0.0104,30598.672,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-05",24,24,5855,,0.013,0.001,2519.7,0.059,0.168,0.0079,42397.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-06",18,16.98,4136.38,,0.009,0.001,1792.538,0.059,0.13,0.0105,30163.688,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-07",18,16.95,4233.82,,0.009,0.001,1836.771,0.059,0.133,0.0106,30907.314,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-08",24,24,5501,,0.012,0.001,2380.3,0.059,0.159,0.008,40053.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-09",24,24,6167,,0.013,0.001,2646.6,0.059,0.177,0.008,44531.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-10",24,24,6244,,0.014,0.001,2684.9,0.059,0.18,0.008,45182.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-11",24,24,5884,,0.013,0.001,2534.6,0.059,0.173,0.0081,42646.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-12",24,24,6236,,0.014,0.001,2683.9,0.059,0.181,0.008,45163.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-13",24,24,6033,,0.013,0.001,2590.3,0.059,0.175,0.008,43589.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-14",24,24,5643,,0.012,0.001,2438.3,0.059,0.166,0.0081,41030.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-15",18,17.04,4187.68,,0.009,0.001,1822.654,0.059,0.13,0.0101,30671.143,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-16",24,24,6296,,0.014,0.001,2702.7,0.059,0.182,0.008,45479.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-17",24,24,5662,,0.012,0.001,2439.9,0.059,0.162,0.0079,41059.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-18",24,24,5938,,0.013,0.001,2550.3,0.059,0.17,0.0079,42914.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-19",24,24,6193,,0.013,0.001,2658,0.059,0.179,0.008,44728.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-20",24,24,5951,,0.013,0.001,2554.2,0.059,0.174,0.0081,42978.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-21",24,24,5625,,0.012,0.001,2424.9,0.059,0.165,0.0081,40806.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-22",18,17.02,3596.88,,0.008,0.001,1612.427,0.059,0.125,0.0118,27131.578,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-23",9,8.98,1577,,0.004,0.001,699.836,0.059,0.049,0.0083,11775.656,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-24",20,19.47,4001.62,,0.009,0.001,1761.763,0.059,0.127,0.0107,29646.54,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-25",18,16.57,4033.25,,0.009,0.0009,1760.377,0.0588,0.127,0.0088,29622.663,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-26",18,16.97,4030.6,,0.009,0.001,1764.599,0.059,0.143,0.0131,29692.779,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-27",18,17.05,4024.42,,0.009,0.001,1769.242,0.059,0.131,0.0108,29772.036,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-28",18,16.82,4073.5,,0.009,0.001,1774.47,0.059,0.135,0.0127,29859.832,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-29",18,16.9,4028.8,,0.009,0.001,1758.494,0.059,0.141,0.0136,29592.236,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-30",18,16.49,3812.08,,0.008,0.001,1667.537,0.059,0.139,0.0138,28058.923,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-12",13,11.67,945.78,,0.004,0.001,718.8,0.0592,0.125,0.0328,12093.321,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-13",6,4.81,834.12,,0.002,0.001,425.47,0.059,0.047,0.0173,7158.952,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-19",6,1.8,54.73,,0,0.0007,74.093,0.0598,0.034,0.0328,1246.266,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-20",11,9.78,2122.86,,0.005,0.001,947.29,0.059,0.107,0.0205,15943.802,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-23",14,12.57,2368,,0.006,0.001,1174.266,0.059,0.125,0.0174,19760.28,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-25",14,12.85,2663.6,,0.006,0.001,1266.24,0.0591,0.117,0.0166,21307.09,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-27",3,0.77,14.68,,0,0.0007,16.919,0.0603,0.006,0.0207,285.129,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-28",11,10.13,2331,,0.005,0.001,1019.687,0.059,0.081,0.0125,17160.711,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-29",18,16.51,3830.44,,0.009,0.001,1685.566,0.0591,0.123,0.0104,28361.885,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-06-30",13,11.63,2491.73,,0.006,0.001,1127.793,0.059,0.094,0.0128,18976.038,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-01",13,12.12,2699.89,,0.006,0.001,1188.567,0.059,0.097,0.0128,20001.78,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-02",13,12.67,2908.49,,0.006,0.001,1278.656,0.059,0.096,0.0112,21515.124,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-03",1,0.48,69.12,,0,0.001,32.112,0.059,0.005,0.018,540.144,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-04",12,11.12,2335,,0.005,0.001,1052.796,0.059,0.103,0.0197,17718.16,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-05",13,11.73,2620.03,,0.006,0.001,1155.18,0.059,0.09,0.0126,19437.573,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-06",16,14.18,3204.7,,0.007,0.001,1404.003,0.0591,0.114,0.0121,23621.176,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-07",13,12.13,2677.74,,0.006,0.001,1173.681,0.059,0.095,0.0128,19750.473,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-08",13,12.19,2656.49,,0.006,0.001,1176.214,0.059,0.1,0.0138,19792.422,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-09",15,14.19,3164.27,,0.007,0.001,1408.703,0.059,0.112,0.0123,23703.932,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-10",16,15.65,3655.9,,0.008,0.001,1593.995,0.059,0.115,0.0101,26826.105,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-11",17,16.28,3687.4,,0.008,0.001,1603.823,0.059,0.118,0.0104,26986.994,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-12",16,12.67,2476.74,,0.006,0.001,1114.339,0.0591,0.077,0.0087,18753.539,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-13",16,14.09,3181.33,,0.007,0.001,1395.897,0.059,0.103,0.0132,23488.957,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-14",13,11.87,2608.27,,0.006,0.001,1149.29,0.059,0.089,0.0124,19341.914,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-15",13,11.93,2641.25,,0.006,0.001,1159.988,0.059,0.088,0.013,19521.537,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-16",13,11.96,2592.75,,0.006,0.001,1156.818,0.059,0.093,0.0141,19465.195,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-17",13,12.63,2880.35,,0.006,0.001,1262.45,0.059,0.098,0.0118,21242.047,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-18",13,11.63,2496.03,,0.006,0.001,1109.801,0.059,0.094,0.0138,18675.027,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-19",13,12.13,2668.35,,0.006,0.001,1172.074,0.059,0.095,0.013,19723.533,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-20",14,13.15,2917.2,,0.006,0.001,1275.15,0.059,0.097,0.0115,21457.675,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-21",14,13.65,3102.2,,0.007,0.001,1353.22,0.059,0.101,0.0107,22774,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-22",13,12.17,2676.05,,0.006,0.001,1178.661,0.059,0.088,0.0105,19834.084,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-23",13,11.77,2542.59,,0.006,0.001,1119.313,0.059,0.087,0.0114,18835.252,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-24",13,12.65,2889.3,,0.006,0.001,1260.1,0.059,0.097,0.0118,21202.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-25",13,12.15,2739.9,,0.006,0.001,1193.93,0.059,0.099,0.0135,20091.865,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-26",13,12.15,2706.25,,0.006,0.001,1198.23,0.059,0.097,0.0131,20163.395,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-27",24,24,5899,,0.013,0.001,2483.7,0.059,0.163,0.0078,41792.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-28",17,16.07,3603.38,,0.008,0.001,1572.994,0.059,0.121,0.0118,26469.564,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-29",18,17.13,3799.24,,0.008,0.001,1668.239,0.059,0.122,0.0102,28074.633,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-30",16,15.11,3432.94,,0.008,0.001,1506.342,0.059,0.112,0.0113,25348.357,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-07-31",24,24,5073,,0.011,0.001,2236,0.059,0.15,0.008,37621.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-01",15,13.69,2966.91,,0.007,0.001,1303.874,0.059,0.103,0.0117,21940.515,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-02",13,12.1,2656.93,,0.006,0.001,1168.991,0.059,0.093,0.0119,19671.416,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-03",13,12.1,2660.45,,0.006,0.001,1169.91,0.059,0.087,0.0112,19688.755,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-04",13,12.17,2649.26,,0.006,0.001,1173.788,0.059,0.095,0.0127,19750.087,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-05",13,12.67,2842.16,,0.006,0.001,1249.026,0.059,0.095,0.0113,21020.046,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-06",12,11.02,2295.92,,0.005,0.001,1027.82,0.059,0.092,0.0142,17294.788,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-07",11,10.3,2309.74,,0.005,0.001,995.445,0.059,0.072,0.0118,16748.277,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-08",13,12.19,2658.14,,0.006,0.001,1175.358,0.059,0.093,0.0121,19776.074,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-09",14,12.62,2720.19,,0.006,0.001,1203.814,0.059,0.097,0.0126,20254.912,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-10",13,11.09,2199.75,,0.005,0.001,989.538,0.059,0.086,0.0164,16649.973,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-11",12,11.17,2450,,0.005,0.001,1082.861,0.059,0.086,0.0118,18221.578,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-12",13,11.95,2632.86,,0.006,0.001,1166.666,0.059,0.096,0.0151,19632.054,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-13",16,15.75,3671.75,,0.008,0.001,1604.6,0.059,0.122,0.0105,26999.625,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-14",15,10.4,1846.45,,0.004,0.001,851.906,0.0591,0.074,0.0139,14333.321,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-15",24,24,5020,,0.011,0.001,2149.4,0.059,0.149,0.0083,36165.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-16",15,14.67,3199.5,,0.007,0.001,1401.627,0.059,0.108,0.0112,23583.433,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-17",24,24,5647,,0.012,0.001,2392.8,0.059,0.161,0.008,40263.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-18",24,24,5051,,0.011,0.001,2152.7,0.059,0.146,0.008,36221.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-19",24,24,5156,,0.011,0.001,2221.8,0.059,0.149,0.008,37384.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-20",18,17.18,3779.21,,0.008,0.001,1651.088,0.059,0.116,0.0093,27784.443,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-21",23,21.96,4902.12,,0.011,0.001,2122.382,0.059,0.145,0.0087,35708.998,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-22",24,24,5787,,0.012,0.001,2448,0.059,0.163,0.0079,41191,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-23",24,24,5597,,0.012,0.001,2369.8,0.059,0.155,0.0078,39877.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-24",24,24,6025,,0.013,0.001,2550.2,0.059,0.172,0.008,42911.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-25",24,24,5843,,0.012,0.001,2472.1,0.059,0.167,0.008,41600.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-26",18,17.14,3769.06,,0.008,0.001,1647.382,0.059,0.122,0.0107,27722.308,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-27",17,16.1,3672.54,,0.008,0.001,1597.84,0.059,0.11,0.0092,26888.118,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-28",17,16.1,3457.96,,0.008,0.001,1536.806,0.059,0.113,0.0106,25858.416,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-29",13,11.75,2470.2,,0.006,0.001,1104.503,0.059,0.093,0.0133,18584.629,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-30",13,12.3,2668.41,,0.006,0.001,1177.319,0.059,0.095,0.012,19810.226,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-08-31",13,12.14,2542.12,,0.006,0.001,1111.274,0.059,0.085,0.0119,18699.107,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-01",13,12.67,2765.16,,0.006,0.001,1225.39,0.059,0.094,0.0114,20620.705,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-02",17,16.08,3350.64,,0.007,0.001,1480.227,0.059,0.107,0.0098,24908.011,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-03",17,16.37,3577.1,,0.008,0.001,1577.267,0.059,0.119,0.0099,26538.97,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-04",17,16.4,3687.52,,0.008,0.001,1625.328,0.059,0.116,0.0091,27347.38,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-05",18,16.67,3757,,0.008,0.001,1661.459,0.059,0.119,0.0099,27956.924,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-06",18,16.42,3680.31,,0.008,0.001,1624.69,0.059,0.119,0.0106,27336.411,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-07",15,13.7,2953.83,,0.007,0.001,1307.118,0.059,0.104,0.0121,21994.276,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-08",14,13.78,3049.78,,0.007,0.001,1324.212,0.059,0.098,0.0104,22282.51,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-09",24,24,5899,,0.013,0.001,2486.6,0.059,0.165,0.0079,41841.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-10",24,24,6051,,0.013,0.001,2553.1,0.059,0.172,0.008,42958.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-11",24,24,6040,,0.013,0.001,2547.5,0.059,0.171,0.008,42866.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-12",19,18.14,4206.26,,0.009,0.001,1823.926,0.059,0.129,0.0093,30690.264,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-13",19,18.19,4196.68,,0.009,0.001,1831.357,0.059,0.128,0.0093,30821.147,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-14",24,24,6025,,0.013,0.001,2557.7,0.059,0.172,0.008,43036.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-15",24,24,5750,,0.012,0.001,2445.3,0.059,0.166,0.0081,41147.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-16",24,24,5719,,0.012,0.001,2426,0.059,0.163,0.008,40822.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-17",24,24,5925,,0.013,0.001,2507.3,0.059,0.169,0.008,42189.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-18",24,23.52,5705.88,,0.012,0.001,2427.332,0.059,0.168,0.0087,40845.068,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-20",13,12.03,2612,,0.006,0.001,1153.621,0.059,0.098,0.0133,19412.106,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-21",24,24,5419,,0.012,0.001,2343.3,0.059,0.152,0.0077,39432.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-22",13,11.68,2589.25,,0.006,0.001,1127.758,0.059,0.095,0.0147,18975.804,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-23",13,11.98,2718.16,,0.006,0.001,1171.038,0.059,0.087,0.0117,19704.86,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-24",12,10.98,2496.76,,0.005,0.001,1078.928,0.059,0.085,0.0129,18155.352,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-25",12,11.63,2674.39,,0.006,0.001,1146.602,0.059,0.085,0.0114,19296.598,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-26",12,11.15,2509.85,,0.005,0.001,1076.91,0.059,0.085,0.0124,18122.19,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-27",14,13.13,2976.63,,0.006,0.001,1270.267,0.059,0.095,0.0113,21374.284,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-28",24,24,5595,,0.012,0.001,2375,0.059,0.16,0.008,39961.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-29",15,14.71,3434.26,,0.007,0.001,1473.632,0.059,0.108,0.0096,24794.137,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-09-30",14,13.2,3032.2,,0.007,0.001,1309.68,0.059,0.099,0.0112,22038.76,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-01",24,24,5861,,0.013,0.001,2482.4,0.059,0.164,0.0078,41765.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-02",24,24,5733,,0.012,0.001,2439.7,0.059,0.161,0.0078,41051.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-03",24,24,5721,,0.012,0.001,2419.3,0.059,0.161,0.0079,40709.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-04",24,24,5701,,0.012,0.001,2395.1,0.059,0.159,0.0079,40300.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-05",24,24,5934,,0.013,0.001,2500.4,0.059,0.17,0.0081,42071,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-06",24,24,5860,,0.013,0.001,2495.4,0.059,0.165,0.0079,41991.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-07",24,24,5781,,0.012,0.001,2450.9,0.059,0.163,0.0079,41243.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-08",24,24,5753,,0.012,0.001,2422.8,0.059,0.162,0.008,40771.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-09",24,24,5719,,0.012,0.001,2410.2,0.059,0.159,0.0078,40558.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-10",18,17,3917.8,,0.008,0.001,1670.56,0.059,0.115,0.0088,28110.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-11",13,11.34,2506,,0.005,0.001,1079.809,0.059,0.083,0.0125,18168.759,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-13",10,9.3,2065.8,,0.005,0.001,902.03,0.059,0.076,0.0133,15179.89,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-14",15,14.65,3284.55,,0.007,0.001,1460.785,0.059,0.106,0.0105,24579.745,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-15",24,24,5824,,0.013,0.001,2477.2,0.059,0.164,0.0078,41683.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-16",24,24,5866,,0.012,0.001,2472.8,0.059,0.161,0.0078,41607.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-17",24,24,5796,,0.012,0.001,2433.3,0.059,0.162,0.0079,40946.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-18",24,24,5531,,0.012,0.001,2333.2,0.059,0.149,0.0076,39263.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-19",24,24,5947,,0.013,0.001,2494.2,0.059,0.162,0.0077,41967.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-20",24,24,5845,,0.012,0.001,2454.2,0.059,0.158,0.0077,41293.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-21",24,24,5686,,0.012,0.001,2393.7,0.059,0.158,0.0078,40278.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-22",24,24,5718,,0.012,0.001,2408.5,0.059,0.154,0.0076,40527.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-23",24,24,5879,,0.012,0.001,2471.7,0.059,0.159,0.0076,41592.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-24",24,24,5915,,0.013,0.001,2484.6,0.059,0.167,0.008,41809,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-25",18,17.01,4184.54,,0.009,0.001,1773.349,0.059,0.121,0.0094,29834.523,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-26",24,24,5555,,0.012,0.001,2338.1,0.059,0.153,0.0078,39345.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-27",24,24,5554,,0.012,0.001,2358.8,0.059,0.152,0.0077,39695.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-28",24,24,5488,,0.012,0.001,2323,0.059,0.155,0.008,39086.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-29",18,17.2,3781.74,,0.008,0.001,1624.064,0.059,0.114,0.0094,27328.158,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-30",18,17.05,4094.03,,0.009,0.001,1748.014,0.059,0.121,0.0093,29418.052,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-10-31",18,16.97,4055.31,,0.009,0.001,1735.486,0.059,0.125,0.0112,29204.284,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-01",18,16.97,4187.92,,0.009,0.001,1822.869,0.059,0.129,0.0101,30670.583,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-02",24,24,6218,,0.013,0.001,2639.6,0.059,0.173,0.0078,44413.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-03",24,24,5704,,0.012,0.001,2429.2,0.059,0.157,0.0077,40881.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-04",24,24,5339,,0.012,0.001,2282.6,0.059,0.152,0.0079,38412.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-05",24,24,5754,,0.012,0.001,2427.8,0.059,0.154,0.0075,40854.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-06",24,24,5958,,0.013,0.001,2512.2,0.059,0.164,0.0078,42272.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-07",24,24,5666,,0.012,0.001,2400.5,0.059,0.158,0.0078,40387.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-08",15,13.75,2905.8,,0.006,0.001,1262.919,0.059,0.096,0.013,21247.319,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-09",18,17.48,3905.39,,0.009,0.001,1694.792,0.059,0.119,0.0094,28516.196,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-10",24,24,5319,,0.012,0.001,2321.7,0.059,0.152,0.0078,39065.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-11",24,24,5457,,0.012,0.001,2374.8,0.059,0.154,0.0078,39960.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-12",18,17.34,3777.03,,0.008,0.001,1667.197,0.059,0.113,0.0097,28052.123,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-13",18,17.15,4101.45,,0.009,0.001,1792.015,0.059,0.127,0.0093,30151.415,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-14",17,16.1,3451.22,,0.008,0.001,1505.602,0.059,0.11,0.0101,25334.664,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-15",18,17,3627.75,,0.008,0.001,1570.01,0.059,0.111,0.0099,26417.895,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-16",24,24,5387,,0.012,0.001,2302.1,0.059,0.145,0.0075,38736.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-17",19,17.98,4122.3,,0.009,0.001,1793.885,0.059,0.121,0.0088,30188.489,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-18",18,17.06,3685.22,,0.008,0.001,1616.937,0.059,0.115,0.0096,27204.192,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-19",12,10.98,2462.11,,0.005,0.001,1070.877,0.059,0.079,0.0125,18017.443,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-20",18,16.98,3661.13,,0.008,0.001,1584.283,0.059,0.112,0.0099,26658.408,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-21",17,16.52,3694.04,,0.008,0.001,1607.71,0.059,0.111,0.0087,27052.798,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-22",17,16.5,3524.5,,0.008,0.001,1523.635,0.059,0.107,0.0091,25639.22,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-23",17,16.5,3534.04,,0.008,0.001,1527.006,0.059,0.111,0.0101,25692.15,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-24",12,11,2497.7,,0.005,0.001,1086.195,0.059,0.082,0.0118,18277.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-25",17,16.58,3604.83,,0.008,0.001,1569.008,0.059,0.12,0.0107,26401.592,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-26",17,16.5,3588.6,,0.008,0.001,1559.47,0.059,0.114,0.0104,26236.233,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-27",17,16.02,3271.66,,0.007,0.001,1436.956,0.059,0.104,0.0102,24180.672,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-28",17,16.4,3653.7,,0.008,0.001,1578.495,0.059,0.114,0.0106,26561.845,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-29",17,16.25,3813.93,,0.008,0.001,1648.801,0.059,0.117,0.0094,27744.463,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-11-30",18,16.67,3933.96,,0.009,0.001,1705.577,0.059,0.126,0.0108,28699.772,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-01",18,17,3657.5,,0.008,0.001,1596.215,0.059,0.117,0.0102,26858.915,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-02",18,16.95,3647.86,,0.008,0.001,1590.02,0.059,0.113,0.0103,26754.699,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-03",18,16.95,3917.54,,0.009,0.001,1702.709,0.059,0.121,0.0104,28651.925,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-04",24,24,5096,,0.011,0.001,2210,0.059,0.145,0.0078,37188.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-05",18,17.05,4075.44,,0.009,0.001,1762.971,0.059,0.124,0.0094,29665.031,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-06",18,16.55,3862.45,,0.008,0.001,1661.155,0.0591,0.121,0.0103,27951.205,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-07",24,24,5424,,0.012,0.001,2325.4,0.059,0.153,0.0078,39127.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-08",24,24,5073,,0.011,0.001,2187.7,0.059,0.144,0.0078,36817.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-09",1,0.47,77.55,,0,0.001,34.122,0.059,0.004,0.013,574.199,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-14",10,8.55,1773.28,,0.004,0.001,799.432,0.059,0.089,0.0244,13451.767,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-15",14,12.84,2719.72,,0.006,0.001,1204.818,0.059,0.105,0.013,20274.04,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-17",10,9.08,1922,,0.004,0.001,849.624,0.0591,0.109,0.0226,14295.668,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-18",18,16.98,3707,,0.008,0.001,1607.228,0.059,0.115,0.0094,27047.916,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-19",18,17.05,3950.76,,0.009,0.001,1704.031,0.059,0.119,0.0097,28674.362,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-20",18,17.05,4070.18,,0.009,0.001,1741.129,0.059,0.12,0.0097,29297.171,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-21",18,17.09,3690.8,,0.008,0.001,1591.222,0.059,0.109,0.0104,26776.665,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-22",13,12.04,2559.68,,0.006,0.001,1107.082,0.059,0.091,0.0137,18629.162,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-23",18,17.13,3845.84,,0.008,0.001,1658.897,0.059,0.117,0.0109,27911.822,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-24",24,24,5656,,0.012,0.001,2417.9,0.059,0.155,0.0076,40684.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-25",18,17.05,3997.39,,0.009,0.001,1716.002,0.059,0.121,0.0099,28878.105,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-26",12,10.97,2294.48,,0.005,0.001,1000.42,0.059,0.089,0.0148,16831.857,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-27",12,11.05,2502.98,,0.005,0.001,1084.129,0.059,0.08,0.0125,18242.665,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-28",24,24,5926,,0.013,0.001,2522,0.059,0.166,0.0078,42437.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-29",18,17.06,3821.61,,0.008,0.001,1653.383,0.059,0.115,0.0092,27822.113,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-30",18,17.01,3779.62,,0.008,0.001,1636.645,0.059,0.114,0.0097,27535.258,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG1",,"2020-12-31",13,11.98,2646.81,,0.006,0.001,1144.536,0.059,0.084,0.0114,19261.195,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-01",11,10.68,2098.2,,0.005,0.001,931.012,0.059,0.105,0.0211,15663.896,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-02",11,9.55,2113.35,,0.005,0.001,914.004,0.059,0.079,0.0162,15382.329,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-03",24,24,5966,,0.013,0.001,2529.6,0.059,0.167,0.0078,42561.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-04",12,11.28,2583,,0.006,0.001,1118.87,0.059,0.106,0.0151,18826.941,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-05",12,11.28,2513.86,,0.006,0.001,1095.429,0.059,0.093,0.0128,18434.176,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-06",24,24,5807,,0.012,0.001,2460.1,0.059,0.161,0.0078,41395.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-07",24,24,5799,,0.012,0.001,2469.9,0.059,0.165,0.0079,41559.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-08",1,0.33,33.33,,0,0.001,18.414,0.059,0.003,0.018,310.101,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-10",10,9.67,1976.03,,0.004,0.001,888.406,0.059,0.119,0.0251,14949.484,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-11",4,3.57,614.83,,0.001,0.001,268.086,0.059,0.022,0.0118,4508.735,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-13",10,9.25,2059.75,,0.005,0.001,900.95,0.0591,0.116,0.0255,15162.675,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-14",24,24,5152,,0.011,0.001,2209,0.059,0.148,0.008,37167.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-15",24,24,5812,,0.012,0.001,2473.1,0.059,0.165,0.0079,41611.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-16",24,23.33,5749.02,,0.012,0.001,2438.189,0.059,0.167,0.0089,41026.11,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-17",18,17.92,4028.72,,0.009,0.001,1751.6,0.059,0.111,0.0076,29469.524,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-18",18,17.28,4235.96,,0.009,0.001,1830.765,0.059,0.133,0.0103,30809.728,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-19",18,17.28,4219.11,,0.009,0.001,1814.047,0.059,0.134,0.0106,30523.828,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-20",24,24,6209,,0.013,0.001,2629.3,0.059,0.175,0.0079,44246.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-21",18,17.28,4145.93,,0.009,0.001,1794.014,0.059,0.132,0.0103,30187.718,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-22",10,9.28,2144.86,,0.005,0.001,939.614,0.059,0.083,0.0143,15812.065,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-23",24,24,5525,,0.012,0.001,2374.7,0.059,0.157,0.0078,39959.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-24",18,17.38,4220.57,,0.009,0.001,1824.057,0.059,0.132,0.0095,30696.32,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-25",12,11.28,2562.11,,0.006,0.001,1122.821,0.059,0.092,0.0125,18895.016,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-26",12,11.37,2629.83,,0.006,0.001,1150.051,0.059,0.101,0.0127,19349.89,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-27",18,17.35,3802.32,,0.008,0.001,1664.856,0.059,0.122,0.0101,28011.856,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-28",10,9.26,2127.81,,0.005,0.001,934.58,0.059,0.078,0.0128,15728.675,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-29",10,9.28,2159.99,,0.005,0.001,947.682,0.059,0.081,0.0134,15946.636,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-30",24,24,5557,,0.012,0.001,2385,0.059,0.158,0.0079,40130.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-01-31",24,24,5505,,0.012,0.001,2363.3,0.059,0.156,0.0079,39769.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-01",18,17.02,4204.25,,0.009,0.001,1798.469,0.059,0.129,0.0103,30263.933,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-02",18,17.25,4216.34,,0.009,0.001,1808.2,0.059,0.131,0.0096,30423.963,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-03",24,23.96,5633.28,,0.012,0.001,2392.148,0.059,0.158,0.0079,40253.408,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-04",24,24,5617,,0.012,0.001,2383.6,0.059,0.157,0.0078,40107.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-05",18,17.31,4257.41,,0.009,0.001,1838.323,0.059,0.132,0.0106,30932.012,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-06",18,17.28,4142.5,,0.009,0.001,1794.395,0.059,0.125,0.0103,30192.728,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-07",18,17.28,4034.59,,0.009,0.001,1747.405,0.059,0.124,0.0093,29401.432,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-08",18,17.25,4046.33,,0.009,0.001,1742.546,0.059,0.126,0.0099,29322.007,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-09",12,11.28,2491.63,,0.006,0.001,1090.411,0.059,0.088,0.012,18351.03,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-10",18,17,4156.46,,0.009,0.001,1801.297,0.059,0.127,0.0102,30306.985,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-11",18,17.02,4205.85,,0.009,0.001,1808.651,0.059,0.129,0.0107,30430.504,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-12",18,17.07,4227.55,,0.009,0.001,1809.104,0.059,0.122,0.0088,30438.994,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-13",18,17.09,4187.05,,0.009,0.001,1795.677,0.059,0.138,0.0118,30216.919,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-14",18,17.3,4235.65,,0.009,0.001,1821.727,0.059,0.133,0.0097,30652.621,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-15",18,17.33,4311.67,,0.009,0.001,1845.567,0.059,0.132,0.0096,31056.257,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-16",17,16.3,3836,,0.008,0.001,1651.56,0.059,0.117,0.0099,27789.152,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-17",24,24,5476,,0.012,0.001,2328,0.059,0.155,0.0079,39169.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-18",18,17.33,4243.63,,0.009,0.001,1823.871,0.059,0.131,0.0096,30691.768,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-19",24,24,5569,,0.012,0.001,2378.1,0.059,0.158,0.0079,40014.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-20",18,17.3,4193.2,,0.009,0.001,1818.152,0.059,0.132,0.0099,30593.536,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-21",24,24,5522,,0.012,0.001,2356.4,0.059,0.158,0.008,39650.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-22",18,17.3,4190.94,,0.009,0.001,1807.996,0.059,0.128,0.0095,30424.364,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-23",12,11.31,2548.43,,0.006,0.001,1111.471,0.059,0.098,0.0132,18699.824,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-24",18,17.3,3989.98,,0.009,0.001,1719.68,0.059,0.124,0.0096,28936.082,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-25",18,17.2,4234,,0.009,0.001,1815.735,0.059,0.131,0.0101,30547.487,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-26",18,17.05,4161.3,,0.009,0.001,1788.295,0.059,0.126,0.0101,30092.795,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-27",18,17.04,4143.74,,0.009,0.001,1776.798,0.059,0.124,0.0096,29897.332,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-28",24,24,5909,,0.013,0.001,2493.2,0.059,0.167,0.008,41955.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-02-29",17,16.09,3778.2,,0.008,0.001,1622.845,0.059,0.117,0.0104,27308.258,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-01",17,16.07,3988.24,,0.009,0.001,1730.703,0.059,0.124,0.01,29124.515,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-02",24,24,5640,,0.012,0.001,2418.3,0.059,0.162,0.008,40696.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-03",19,17.48,4273,,0.009,0.001,1851.408,0.059,0.132,0.0097,31154.644,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-04",18,17.08,4265.32,,0.009,0.001,1835.644,0.059,0.128,0.0092,30889.516,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-05",24,24,5914,,0.013,0.001,2523.2,0.059,0.169,0.008,42455.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-06",18,17.29,4227.82,,0.009,0.001,1821.87,0.059,0.13,0.0098,30658.482,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-07",18,17.13,4313.05,,0.009,0.001,1859.573,0.059,0.136,0.0103,31292.691,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-08",24,24,5566,,0.012,0.001,2388.4,0.059,0.159,0.0079,40191.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-09",24,24,6260,,0.013,0.001,2664,0.059,0.178,0.0079,44828.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-10",24,24,6320,,0.014,0.001,2695.1,0.059,0.181,0.008,45349.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-11",24,24,5952,,0.013,0.001,2542.8,0.059,0.172,0.008,42788.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-12",24,24,6312,,0.014,0.001,2690.4,0.059,0.183,0.0081,45268,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-13",24,24,6101,,0.013,0.001,2598.1,0.059,0.175,0.008,43717.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-14",24,24,5699,,0.012,0.001,2440,0.059,0.166,0.0081,41056.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-15",18,17.2,4254.99,,0.009,0.001,1835.869,0.059,0.132,0.0099,30892.813,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-16",24,24,6363,,0.014,0.001,2699.4,0.059,0.182,0.008,45422.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-17",24,24,5695,,0.012,0.001,2437.1,0.059,0.161,0.0079,41009.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-18",24,24,5979,,0.013,0.001,2546.8,0.059,0.17,0.008,42858.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-19",24,24,6230,,0.013,0.001,2652.9,0.059,0.169,0.0075,44640,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-20",24,24,5973,,0.013,0.001,2546.3,0.059,0.17,0.0079,42845.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-21",24,24,5673,,0.012,0.001,2423.3,0.059,0.161,0.0079,40780.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-22",18,17.31,3642.47,,0.008,0.001,1628.996,0.059,0.117,0.0095,27413.455,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-23",10,9.02,1590.34,,0.004,0.001,703.864,0.059,0.049,0.0153,11844.468,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-24",19,18.6,3904.6,,0.009,0.001,1693.76,0.059,0.125,0.011,28501.78,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-25",18,16.65,4087.15,,0.009,0.001,1768.225,0.059,0.133,0.0101,29752.395,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-26",18,17.07,4074.27,,0.009,0.001,1770.619,0.059,0.128,0.0099,29793.635,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-27",18,17.26,4110.34,,0.009,0.001,1794.578,0.059,0.137,0.0108,30195.514,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-28",18,16.97,4123.44,,0.009,0.001,1783.265,0.059,0.134,0.0122,30006.099,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-29",18,17.05,4096.03,,0.009,0.001,1776.107,0.059,0.142,0.0126,29887.102,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-30",18,16.82,3882.98,,0.009,0.001,1692.256,0.059,0.138,0.0122,28477.432,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-26",9,7.44,1207.65,,0.003,0.001,589.58,0.059,0.09,0.0277,9921.206,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-27",11,10.42,2218.68,,0.005,0.001,1017.57,0.059,0.08,0.0148,17123.184,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-28",12,10.8,2406.2,,0.005,0.001,1059.848,0.059,0.087,0.0131,17831.656,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-29",17,16.01,3785.19,,0.008,0.001,1647.139,0.059,0.119,0.0105,27714.179,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-06-30",13,10.96,2405.39,,0.005,0.001,1078.748,0.059,0.092,0.0158,18151.638,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-01",12,11,2576.46,,0.006,0.001,1107.111,0.059,0.099,0.0155,18630.354,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-02",13,12.07,2873,,0.006,0.001,1239.973,0.059,0.098,0.0112,20864.401,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-03",1,0.42,54.6,,0,0.001,26.586,0.059,0.005,0.024,447.552,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-04",11,10.13,2307,,0.005,0.001,1006.891,0.059,0.1,0.0179,16943.544,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-05",12,11.15,2561.65,,0.006,0.001,1112.83,0.059,0.095,0.0136,18723.91,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-06",15,13.57,3119.66,,0.007,0.001,1351.606,0.059,0.101,0.0111,22744.43,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-07",13,11.37,2589.75,,0.006,0.0009,1120.236,0.0591,0.09,0.0106,18851.245,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-08",12,11.34,2589.88,,0.006,0.001,1116.966,0.059,0.093,0.0123,18795.194,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-09",15,13.52,3137,,0.007,0.001,1371.859,0.0591,0.105,0.011,23084.215,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-10",16,15.25,3663.5,,0.008,0.001,1580.25,0.059,0.115,0.0124,26592.175,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-11",17,15.63,3652.4,,0.008,0.001,1576.909,0.059,0.123,0.0121,26533.831,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-12",16,14.6,3203.44,,0.007,0.001,1399.44,0.059,0.101,0.0116,23550.333,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-13",15,13.19,3114.44,,0.007,0.001,1340.095,0.059,0.104,0.0141,22548.772,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-14",12,11.35,2574.4,,0.006,0.001,1113.75,0.059,0.088,0.0113,18741.305,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-15",12,11.35,2592.08,,0.006,0.001,1124.234,0.059,0.088,0.0109,18920.072,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-16",12,11.36,2572.35,,0.006,0.001,1130.003,0.059,0.088,0.0103,19015.463,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-17",12,11.65,2787.55,,0.006,0.001,1192.18,0.059,0.093,0.0123,20061.265,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-18",13,10.92,2450.04,,0.005,0.001,1068.238,0.0591,0.092,0.0136,17974.124,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-19",12,11.07,2549.66,,0.006,0.001,1092.659,0.059,0.091,0.0142,18385.611,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-20",14,12.65,2880.51,,0.006,0.001,1245.597,0.059,0.097,0.0136,20963.195,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-21",14,12.83,2893.31,,0.006,0.001,1259.205,0.059,0.098,0.0133,21189.283,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-22",13,11.61,2622.52,,0.006,0.001,1138.023,0.059,0.088,0.0132,19150.395,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-23",13,11.07,2477.63,,0.005,0.001,1075.845,0.059,0.093,0.015,18101.323,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-24",12,11.97,2839.93,,0.006,0.001,1215.508,0.059,0.098,0.0109,20450.751,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-25",12,11.34,2648.98,,0.006,0.001,1134.954,0.059,0.094,0.0126,19095.892,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-26",11,9.9,2323.46,,0.005,0.001,994.817,0.059,0.083,0.0171,16742.376,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-27",24,24,5925,,0.013,0.001,2483.7,0.059,0.166,0.008,41794.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-28",16,14.96,3491.24,,0.008,0.001,1492.392,0.059,0.114,0.0123,25111.698,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-29",17,16.27,3711.07,,0.008,0.001,1604.279,0.059,0.114,0.0094,26995.413,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-30",15,14.03,3317.84,,0.007,0.001,1425.03,0.059,0.108,0.0117,23976.404,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-07-31",16,14.68,2824.29,,0.006,0.001,1229.014,0.059,0.092,0.0103,20681.629,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-01",14,12.73,2879.24,,0.006,0.001,1240.857,0.059,0.099,0.0113,20881.756,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-02",12,11.26,2564.24,,0.006,0.001,1109.937,0.059,0.092,0.0121,18679.445,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-03",12,11.32,2557.73,,0.006,0.001,1102.21,0.059,0.092,0.0118,18547.421,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-04",12,11.4,2589.38,,0.006,0.001,1120.03,0.059,0.095,0.0123,18847.816,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-05",12,11.93,2769.38,,0.006,0.001,1191.471,0.059,0.095,0.0108,20048.844,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-06",12,10.16,2263.9,,0.005,0.0009,979.974,0.0585,0.094,0.0128,16488.338,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-07",13,12.18,2695,,0.006,0.001,1175.718,0.059,0.093,0.0139,19784.632,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-08",13,11.66,2634.88,,0.006,0.001,1134.71,0.059,0.094,0.0145,19090.887,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-09",14,11.97,2670.91,,0.006,0.001,1154.371,0.0591,0.091,0.0135,19424.896,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-10",11,9.92,2027.43,,0.004,0.001,888.093,0.059,0.092,0.0191,14944.972,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-11",11,10.33,2348.85,,0.005,0.001,1016.351,0.059,0.086,0.0124,17100.024,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-12",12,11.28,2584.52,,0.006,0.001,1117.455,0.059,0.088,0.0117,18804.818,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-13",15,14.95,3589.15,,0.008,0.001,1537.24,0.059,0.117,0.0099,25864.47,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-14",17,14.83,2966.79,,0.007,0.001,1327.918,0.059,0.102,0.0138,22344.841,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-15",24,23.95,5017.85,,0.011,0.001,2139.82,0.059,0.148,0.0083,36007.105,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-16",15,14.08,3155,,0.007,0.001,1360.28,0.0591,0.104,0.0109,22889.736,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-17",24,24,5673,,0.012,0.001,2397.5,0.059,0.16,0.008,40341.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-18",24,24,5058,,0.011,0.001,2150.5,0.059,0.145,0.008,36185.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-19",24,24,5262,,0.011,0.001,2259.6,0.059,0.152,0.008,38021.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-20",18,16.46,3731.06,,0.008,0.001,1605.32,0.059,0.112,0.0093,27011.254,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-21",23,21.24,4851.73,,0.01,0.001,2078.499,0.059,0.145,0.0111,34974.314,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-22",24,24,5837,,0.012,0.001,2466.4,0.059,0.166,0.008,41503.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-23",24,24,5621,,0.012,0.001,2372.6,0.059,0.159,0.008,39926.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-24",24,24,6045,,0.013,0.001,2547.6,0.059,0.172,0.008,42867.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-25",24,24,5847,,0.012,0.001,2454.9,0.059,0.165,0.008,41311.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-26",17,16.06,3686.03,,0.008,0.001,1572.867,0.059,0.115,0.0105,26466.949,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-27",16,15,3572.75,,0.008,0.001,1523.212,0.059,0.117,0.0124,25632.083,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-28",16,15.05,3334.79,,0.007,0.001,1452.842,0.059,0.107,0.011,24446.403,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-29",12,10.82,2405.65,,0.005,0.001,1042.953,0.059,0.088,0.0122,17546.525,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-30",12,11.3,2554.95,,0.005,0.001,1087.642,0.059,0.091,0.0123,18300.86,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-08-31",12,11.3,2457.19,,0.005,0.001,1055.108,0.059,0.087,0.0122,17752.155,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-01",12,11.92,2707.04,,0.006,0.001,1174.352,0.059,0.089,0.0102,19761.552,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-02",16,15.27,3327.8,,0.007,0.001,1442.287,0.059,0.106,0.01,24267.38,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-03",17,15.54,3529.26,,0.008,0.001,1533.531,0.059,0.114,0.0113,25805.702,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-04",17,15.75,3627.6,,0.008,0.001,1577.045,0.059,0.111,0.0115,26538.275,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-05",15,13.33,3147.52,,0.007,0.001,1353.549,0.059,0.099,0.012,22776.793,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-06",17,15.57,3589.02,,0.008,0.001,1559.152,0.059,0.112,0.0102,26235.836,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-07",14,12.98,2892.1,,0.006,0.001,1253.758,0.059,0.092,0.0112,21099.456,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-08",14,13.33,3018.98,,0.007,0.001,1299.388,0.059,0.098,0.0122,21864.909,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-09",24,24,5929,,0.013,0.001,2494.5,0.059,0.164,0.0078,41973.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-10",24,24,6057,,0.013,0.001,2546.3,0.059,0.173,0.0081,42845.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-11",24,24,6032,,0.013,0.001,2531.2,0.059,0.17,0.008,42590.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-12",18,17.03,4087.41,,0.009,0.001,1735.1,0.059,0.124,0.0098,29198.456,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-13",18,17.05,4082.68,,0.009,0.001,1742.189,0.059,0.125,0.0099,29318.363,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-14",24,24,5971,,0.013,0.001,2527.4,0.059,0.169,0.008,42531,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-15",24,24,5714,,0.012,0.001,2426.7,0.059,0.15,0.0071,40836.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-16",24,24,5679,,0.012,0.001,2418.3,0.059,0.163,0.008,40690.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-17",24,24,5912,,0.013,0.001,2507.5,0.059,0.17,0.008,42192.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-18",24,23.43,5668.47,,0.012,0.001,2407.63,0.059,0.164,0.0085,40512.094,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-21",8,7.33,1492.27,,0.003,0.001,650.222,0.059,0.085,0.0253,10943.885,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-22",13,11.87,2583.61,,0.006,0.001,1124.279,0.059,0.092,0.0132,18920.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-23",13,12.2,2721.2,,0.006,0.001,1178.544,0.059,0.09,0.0112,19832.196,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-24",12,11.1,2486.48,,0.005,0.001,1079.646,0.059,0.09,0.0133,18169.458,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-25",12,11.98,2693.38,,0.006,0.001,1163.15,0.059,0.092,0.0105,19570.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-26",12,11.4,2512,,0.005,0.001,1089.14,0.059,0.092,0.0118,18324.32,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-27",14,13.45,2984.95,,0.007,0.001,1287.445,0.059,0.102,0.0107,21665.68,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-28",24,24,5595,,0.012,0.001,2371.6,0.059,0.157,0.0079,39906.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-29",16,14.97,3480.6,,0.008,0.001,1497.957,0.059,0.112,0.0099,25209.317,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-09-30",15,13.48,3104.9,,0.007,0.001,1344.717,0.059,0.106,0.0117,22628.488,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-01",24,24,5943,,0.013,0.001,2516.1,0.059,0.169,0.008,42338.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-02",24,24,5812,,0.012,0.001,2473.1,0.059,0.167,0.008,41615.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-03",24,24,5804,,0.012,0.001,2453.4,0.059,0.165,0.008,41279.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-04",24,24,5779,,0.012,0.001,2428,0.059,0.162,0.0079,40857.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-05",24,24,6027,,0.013,0.001,2530.8,0.059,0.171,0.008,42583.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-06",24,24,5988,,0.013,0.001,2549.8,0.059,0.171,0.008,42904.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-07",24,24,5901,,0.013,0.001,2497.7,0.059,0.167,0.008,42031.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-08",24,24,5863,,0.012,0.001,2468.5,0.059,0.166,0.008,41532.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-09",24,24,5830,,0.012,0.001,2448.7,0.059,0.162,0.0079,41205.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-10",18,17.18,4007.82,,0.009,0.001,1704.176,0.059,0.118,0.0087,28676.294,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-11",13,12.2,2787.7,,0.006,0.001,1197.099,0.059,0.094,0.0113,20143.716,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-12",24,24,5693,,0.012,0.001,2418.8,0.059,0.161,0.0079,40700.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-13",1,0.35,31.15,,0,0.001,19.355,0.059,0.003,0.02,325.745,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-14",14,13.6,3162.8,,0.007,0.001,1381.5,0.059,0.104,0.0128,23247.92,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-15",24,24,5863,,0.013,0.001,2496.8,0.059,0.164,0.0078,42010.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-16",24,24,5902,,0.013,0.001,2494.5,0.059,0.166,0.0079,41972.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-17",24,24,5839,,0.012,0.001,2462.1,0.059,0.165,0.008,41428.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-18",24,24,5572,,0.012,0.001,2354.2,0.059,0.156,0.0079,39614.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-19",24,24,5961,,0.013,0.001,2501.2,0.059,0.166,0.0079,42091.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-20",24,24,5894,,0.012,0.001,2474.4,0.059,0.165,0.0079,41635,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-21",24,24,5761,,0.012,0.001,2426.1,0.059,0.161,0.0079,40824.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-22",24,24,5749,,0.012,0.001,2426.4,0.059,0.163,0.008,40831.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-23",24,24,5881,,0.013,0.001,2477.4,0.059,0.168,0.008,41689.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-24",24,24,5935,,0.013,0.001,2498.6,0.059,0.169,0.008,42043.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-25",18,17.36,4260.12,,0.009,0.001,1812.264,0.059,0.129,0.0092,30492.972,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-26",24,24,5575,,0.012,0.001,2345.1,0.059,0.155,0.0079,39460.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-27",24,24,5583,,0.012,0.001,2372.7,0.059,0.157,0.0079,39926.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-28",24,24,5509,,0.012,0.001,2337.2,0.059,0.157,0.008,39327.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-29",17,16.1,3612.88,,0.008,0.001,1534.968,0.059,0.12,0.0116,25829.296,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-30",18,17.41,4165.58,,0.009,0.001,1784.885,0.059,0.13,0.0096,30035.927,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-10-31",18,17.43,4101.54,,0.009,0.001,1772.203,0.059,0.131,0.0099,29818.441,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-01",19,17.47,4269.32,,0.009,0.001,1869.204,0.0591,0.135,0.0097,31450.835,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-02",24,24,6248,,0.013,0.001,2652.8,0.059,0.177,0.0079,44640,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-03",24,24,5733,,0.012,0.001,2440.2,0.059,0.161,0.0078,41062.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-04",24,24,5324,,0.012,0.001,2277.9,0.059,0.153,0.008,38330,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-05",24,24,5717,,0.012,0.001,2412.5,0.059,0.157,0.0077,40594.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-06",24,24,5913,,0.013,0.001,2494.6,0.059,0.167,0.0079,41978.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-07",24,23.6,5350,,0.012,0.001,2282.82,0.059,0.153,0.008,38412.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-08",15,14.03,2850.44,,0.006,0.001,1250.376,0.059,0.1,0.0132,21042.994,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-09",18,17.77,3827.3,,0.008,0.001,1671.108,0.059,0.121,0.0092,28121.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-10",3,2.13,439.5,,0.001,0.001,191.268,0.059,0.015,0.0213,3218.072,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-14",10,9.33,2030.66,,0.005,0.001,896.852,0.059,0.095,0.0218,15092.33,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-15",18,17.28,3680.7,,0.008,0.001,1594.184,0.059,0.115,0.0096,26825.14,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-16",24,23.62,5225.34,,0.011,0.001,2239.68,0.059,0.148,0.008,37686.07,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-17",18,17.12,4047.81,,0.009,0.001,1734.394,0.059,0.127,0.0121,29186.288,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-18",18,17.33,3733,,0.008,0.001,1641.683,0.059,0.119,0.0093,27624.805,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-19",12,11.27,2513.33,,0.006,0.001,1094.029,0.059,0.087,0.0119,18410.357,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-20",18,17.36,3735.36,,0.008,0.001,1619.348,0.059,0.115,0.0093,27247.18,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-21",18,16.88,3802.43,,0.008,0.001,1650.455,0.059,0.118,0.0117,27769.891,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-22",17,16.85,3600.27,,0.008,0.001,1555.745,0.059,0.113,0.0089,26176.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-23",17,16.8,3611.44,,0.008,0.001,1558.248,0.059,0.112,0.0092,26223.128,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-24",12,11.28,2582.42,,0.006,0.001,1121.206,0.059,0.093,0.0125,18863.616,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-25",17,16.88,3673.08,,0.008,0.001,1596.662,0.059,0.117,0.0092,26867.342,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-26",17,16.85,3698.93,,0.008,0.001,1603.02,0.059,0.115,0.0091,26973.437,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-27",17,16.33,3357.4,,0.007,0.001,1471.81,0.059,0.108,0.0097,24766.632,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-28",18,16.93,3771.04,,0.008,0.001,1632.979,0.059,0.124,0.0101,27479.604,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-29",18,16.78,3943.28,,0.009,0.001,1705.836,0.0591,0.125,0.0104,28701.759,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-11-30",18,17.36,4245.58,,0.009,0.001,1825.254,0.059,0.128,0.0093,30711.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-01",18,17.38,3812.76,,0.008,0.001,1658.534,0.059,0.121,0.0095,27907.068,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-02",18,17.05,3757.94,,0.008,0.001,1628.406,0.059,0.12,0.011,27401.874,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-03",18,17.05,4086.16,,0.009,0.001,1760.284,0.059,0.13,0.0107,29620.653,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-04",24,24,5211,,0.011,0.001,2246,0.059,0.147,0.0078,37791.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-05",18,17.33,4272.71,,0.009,0.001,1835.861,0.059,0.128,0.0093,30893.156,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-06",18,17.3,4053.06,,0.009,0.001,1750.376,0.059,0.128,0.0096,29453.692,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-07",24,24,5599,,0.012,0.001,2388.8,0.059,0.161,0.008,40192.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-08",24,24,5256,,0.011,0.001,2248.7,0.059,0.147,0.0078,37839.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-09",1,0.47,78.02,,0,0.001,34.028,0.059,0.005,0.016,572.883,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-13",1,0.97,14.55,,0,0.001,34.047,0.059,0.032,0.113,572.688,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-14",19,18.17,3621.81,,0.009,0.001,1710.102,0.059,0.134,0.0113,28778.717,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-15",14,13.14,2762.34,,0.006,0.001,1214.446,0.059,0.093,0.0104,20431.12,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-17",10,9.23,1951,,0.004,0.001,867.411,0.059,0.105,0.0247,14596.652,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-18",19,18.01,3847.2,,0.009,0.001,1689.705,0.059,0.123,0.0102,28435.083,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-19",18,17.4,4021.94,,0.009,0.001,1738.26,0.059,0.123,0.0091,29248.362,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-20",18,17.39,4136.13,,0.009,0.001,1776.461,0.059,0.122,0.0087,29893.224,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-21",18,17.28,3731.8,,0.008,0.001,1610.699,0.059,0.108,0.0094,27100.322,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-22",13,12.3,2610.8,,0.006,0.001,1134.81,0.059,0.09,0.0112,19094.46,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-23",18,17.35,3891.55,,0.008,0.001,1680.595,0.059,0.122,0.01,28275.925,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-24",24,24,5665,,0.012,0.001,2410.2,0.059,0.153,0.0075,40553.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-25",18,17.41,4067.39,,0.009,0.001,1749.811,0.059,0.125,0.0092,29443.122,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-26",13,11.74,2387.66,,0.005,0.001,1060.613,0.059,0.092,0.0151,17849.534,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-27",12,11.4,2556.36,,0.006,0.001,1116.358,0.059,0.089,0.0112,18787.348,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-28",24,24,5961,,0.013,0.001,2535,0.059,0.163,0.0076,42657.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-29",18,17.41,3890.99,,0.009,0.001,1689.212,0.059,0.117,0.0087,28424.831,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-30",19,16.82,3726.81,,0.008,0.0009,1614.384,0.0588,0.12,0.0114,27166.023,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG2",,"2020-12-31",13,12.35,2717.72,,0.006,0.001,1180.979,0.059,0.09,0.0103,19871.626,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-01",13,12.67,2282.02,,0.005,0.001,1043.836,0.059,0.106,0.019,17562.962,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-02",11,10.41,2195.02,,0.005,0.001,951.306,0.059,0.081,0.0124,16008.712,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-03",24,24,5912,,0.012,0.001,2463,0.059,0.165,0.008,41444.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-04",13,12.11,2654.7,,0.006,0.001,1150.16,0.059,0.097,0.0147,19350.327,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-05",13,12.13,2597.63,,0.006,0.001,1128.786,0.059,0.09,0.0128,18990.862,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-06",24,24,5760,,0.012,0.001,2394.1,0.059,0.155,0.0077,40287.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-07",24,24,5745,,0.012,0.001,2405.2,0.059,0.162,0.008,40472.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-08",1,0.43,55.47,,0,0.001,26.445,0.059,0.005,0.023,444.706,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-10",12,11.6,2175,,0.005,0.001,1010.78,0.059,0.109,0.0205,17006.44,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-11",4,3.7,640.4,,0.001,0.001,271.99,0.059,0.024,0.0118,4577.74,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-13",12,11.63,2212.3,,0.005,0.001,1010.319,0.059,0.121,0.0238,17000.447,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-14",24,24,5126,,0.011,0.001,2156.5,0.059,0.119,0.0062,36285.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-15",24,24,5756,,0.012,0.001,2404,0.059,0.158,0.0077,40450.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-16",24,23.45,5714.25,,0.012,0.001,2381.775,0.059,0.162,0.0086,40081.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-17",19,18.42,4049.98,,0.009,0.001,1742.542,0.059,0.121,0.0118,29323.91,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-18",19,17.98,4277.99,,0.009,0.001,1829.288,0.059,0.134,0.0113,30782.751,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-19",19,17.93,4256.27,,0.009,0.001,1811.842,0.059,0.128,0.0103,30486.821,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-20",24,24,6154,,0.013,0.001,2559,0.059,0.173,0.008,43062.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-21",19,17.89,4199.45,,0.009,0.001,1793.699,0.059,0.136,0.0129,30184.082,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-22",11,9.98,2215.53,,0.005,0.001,962.872,0.059,0.073,0.0139,16201.221,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-23",24,24,5471,,0.012,0.001,2312.6,0.059,0.147,0.0075,38916.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-24",19,17.95,4225.22,,0.009,0.001,1813.251,0.059,0.134,0.0122,30510.053,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-25",13,11.86,2621.51,,0.006,0.001,1139.483,0.059,0.088,0.0151,19174.659,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-26",13,11.93,2679.18,,0.006,0.001,1162.932,0.059,0.092,0.015,19566.871,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-27",19,17.9,3905.51,,0.009,0.001,1684.706,0.059,0.121,0.0122,28349.285,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-28",11,10.07,2205.09,,0.005,0.001,968.399,0.059,0.079,0.0143,16295.994,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-29",11,10.07,2236.85,,0.005,0.001,980.242,0.059,0.081,0.0145,16495.204,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-30",24,24,5525,,0.012,0.001,2327.6,0.059,0.143,0.0071,39166.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-01-31",24,24,5549,,0.012,0.001,2342.9,0.059,0.146,0.0073,39422.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-01",19,17.6,4251.19,,0.009,0.001,1797.124,0.059,0.135,0.0125,30239.927,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-02",19,17.88,4279.96,,0.009,0.001,1814.769,0.059,0.131,0.0113,30539.967,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-03",24,24,5593,,0.012,0.001,2330.8,0.059,0.154,0.0078,39221.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-04",24,24,5600,,0.012,0.001,2355.1,0.059,0.149,0.0074,39628.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-05",19,17.88,4363.31,,0.009,0.001,1862.417,0.0591,0.141,0.013,31337.967,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-06",19,17.87,4101.93,,0.009,0.001,1757.751,0.059,0.124,0.0122,29579.117,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-07",19,17.78,4214.67,,0.009,0.001,1795.089,0.059,0.118,0.0109,30207.49,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-08",19,17.8,4104.65,,0.009,0.001,1746.96,0.0591,0.114,0.0079,29398.25,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-09",13,11.87,2551.81,,0.006,0.001,1107.169,0.059,0.077,0.0135,18632.094,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-10",19,17.58,4266.03,,0.009,0.001,1819.418,0.059,0.131,0.0117,30613.03,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-11",19,17.6,4293.5,,0.009,0.001,1827.035,0.059,0.149,0.013,30746.515,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-12",19,17.7,4279.71,,0.009,0.001,1818.9,0.059,0.139,0.0127,30604.293,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-13",19,17.67,4242.64,,0.009,0.001,1807.667,0.059,0.143,0.0127,30417.742,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-14",19,18.03,4323.5,,0.009,0.001,1842.68,0.059,0.133,0.0107,31007.758,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-15",19,17.99,4393.55,,0.009,0.001,1861.881,0.059,0.135,0.0105,31328.465,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-16",18,16.96,3917.98,,0.008,0.001,1667.142,0.059,0.123,0.0114,28052.867,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-17",24,24,5474,,0.012,0.001,2284.8,0.059,0.151,0.0078,38448.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-18",19,17.75,4334.46,,0.009,0.001,1832.504,0.059,0.13,0.0108,30836.493,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-19",24,24,5575,,0.012,0.001,2337.5,0.059,0.155,0.0078,39335.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-20",19,17.65,4223.84,,0.009,0.001,1809.137,0.059,0.143,0.0139,30441.577,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-21",24,24,5492,,0.012,0.001,2298.4,0.059,0.15,0.0077,38674.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-22",19,17.87,4246.72,,0.009,0.001,1808.506,0.059,0.132,0.0122,30429.49,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-23",13,11.9,2629.52,,0.006,0.001,1135.194,0.059,0.094,0.016,19099.765,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-24",19,17.89,4033.56,,0.009,0.001,1718.777,0.059,0.134,0.0146,28923.035,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-25",19,17.75,4309.5,,0.009,0.001,1821.87,0.0591,0.14,0.0133,30660.245,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-26",19,17.53,4235.93,,0.009,0.001,1797.028,0.0591,0.135,0.0132,30237.394,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-27",19,17.57,4240.84,,0.009,0.001,1794.57,0.059,0.136,0.0146,30199.299,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-28",24,24,5862,,0.012,0.001,2426.1,0.059,0.159,0.0078,40825.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-02-29",18,16.67,3807.64,,0.008,0.001,1623.541,0.059,0.127,0.0131,27318.157,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-01",18,16.67,4014.6,,0.009,0.001,1727.15,0.059,0.142,0.0132,29063.079,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-02",24,24,5640,,0.012,0.001,2367.1,0.059,0.16,0.008,39829.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-03",19,18.19,4361.81,,0.009,0.001,1871.561,0.059,0.152,0.0126,31495.539,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-04",19,17.67,4374,,0.009,0.001,1856.029,0.0591,0.142,0.0126,31232.894,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-05",24,24,5913,,0.012,0.001,2475.7,0.059,0.168,0.008,41657.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-06",19,17.67,4321.5,,0.009,0.001,1832.861,0.059,0.137,0.0124,30845.642,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-07",19,17.62,4462.6,,0.01,0.001,1890.118,0.0591,0.146,0.0122,31803.115,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-08",24,24,5588,,0.012,0.001,2348,0.059,0.156,0.0079,39509.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-09",24,24,6299,,0.013,0.001,2626.7,0.059,0.175,0.0079,44199.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-10",24,24,6407,,0.013,0.001,2671.5,0.059,0.179,0.008,44947.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-11",24,24,5966,,0.013,0.001,2497,0.059,0.169,0.008,42017.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-12",24,24,6366,,0.013,0.001,2657,0.059,0.183,0.0082,44708.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-13",24,24,6167,,0.013,0.001,2570.8,0.059,0.172,0.008,43255.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-14",24,24,5749,,0.012,0.001,2409,0.059,0.159,0.0077,40538.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-15",19,17.75,4396.8,,0.009,0.001,1867.425,0.059,0.139,0.0118,31425.48,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-16",24,24,6450,,0.014,0.001,2683.2,0.059,0.174,0.0077,45150.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-17",24,24,5703,,0.012,0.001,2391.4,0.059,0.159,0.0079,40243,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-18",24,24,5973,,0.013,0.001,2495.3,0.059,0.165,0.0078,41986.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-19",24,24,6229,,0.013,0.001,2603.6,0.059,0.175,0.008,43812.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-20",24,24,5953,,0.013,0.001,2487.8,0.059,0.163,0.0077,41861.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-21",24,24,5693,,0.012,0.001,2384.8,0.059,0.148,0.0072,40127,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-22",17,14.23,2955.76,,0.006,0.001,1274.835,0.059,0.096,0.0152,21450.753,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-23",24,24,5208,,0.012,0.001,2310.2,0.059,0.154,0.0079,38875.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-24",24,24,5250,,0.011,0.001,2265.8,0.059,0.142,0.0073,38128.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-25",19,17.4,4165.71,,0.009,0.001,1780.271,0.0591,0.152,0.0148,29956.92,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-26",19,17.64,4118.15,,0.009,0.001,1767.608,0.059,0.134,0.0119,29745.054,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-27",18,16.93,4087.4,,0.009,0.001,1736.077,0.059,0.127,0.0114,29210.934,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-28",19,17.58,4217.04,,0.009,0.001,1799.556,0.059,0.142,0.0132,30283.121,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-29",19,17.67,4147.6,,0.009,0.001,1779.752,0.059,0.138,0.0129,29946.661,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-30",19,17.4,4018.19,,0.009,0.001,1715.673,0.059,0.139,0.0134,28869.534,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-17",7,6.07,746.28,,0.002,0.001,395.198,0.0591,0.067,0.0379,6648.54,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-18",4,3.65,556.05,,0.002,0.001,344.485,0.059,0.027,0.0103,5794.585,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-19",5,1.56,10.53,,0,0.001,49.858,0.0592,0.038,0.0824,838.965,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-20",14,13.1,2547.68,,0.006,0.001,1180.85,0.0591,0.126,0.0203,19869.08,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-23",2,0.87,5.73,,0,0.001,27.058,0.059,0.022,0.0925,455.012,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-26",12,11.07,2171.42,,0.005,0.001,1041.263,0.059,0.102,0.0183,17520.125,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-27",9,8.75,2051.75,,0.004,0.001,878.575,0.059,0.069,0.0112,14786.15,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-28",12,11.35,2492.31,,0.005,0.001,1088.337,0.059,0.09,0.0126,18314.75,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-29",17,16.07,3793.9,,0.008,0.001,1613.91,0.059,0.125,0.0125,27158.087,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-06-30",12,10.39,2349.36,,0.005,0.001,1015.804,0.059,0.086,0.0148,17093.717,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-01",12,10.87,2547.05,,0.005,0.001,1070.768,0.059,0.093,0.0159,18015.904,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-02",12,11.63,2815.35,,0.006,0.001,1178.835,0.059,0.091,0.0119,19836.844,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-03",1,0.4,51.6,,0,0.001,24.96,0.059,0.005,0.022,420,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-04",10,9.87,2283.8,,0.005,0.001,971.693,0.059,0.087,0.0148,16348.995,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-05",12,11.01,2536.75,,0.005,0.001,1079.454,0.059,0.084,0.0125,18162.424,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-06",15,13.35,3123.52,,0.007,0.001,1317.961,0.059,0.104,0.0136,22176.982,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-07",12,11.12,2569.1,,0.005,0.001,1078.802,0.059,0.085,0.0133,18153.058,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-08",12,11.15,2575.38,,0.005,0.001,1086.537,0.059,0.092,0.0133,18281.919,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-09",14,13.22,3124.42,,0.007,0.001,1328.454,0.059,0.097,0.0102,22352,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-10",15,14.77,3663.59,,0.008,0.001,1533.119,0.059,0.103,0.0081,25797.439,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-11",16,15.05,3619.85,,0.008,0.001,1515.96,0.059,0.109,0.01,25508.885,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-12",15,14.02,3110.47,,0.007,0.001,1300.179,0.059,0.088,0.0096,21880.991,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-13",15,13.04,3095.1,,0.007,0.001,1289.424,0.059,0.092,0.0149,21695.385,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-14",12,11.07,2558.49,,0.005,0.001,1072.438,0.059,0.079,0.011,18043.827,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-15",12,11.03,2533.6,,0.005,0.001,1066.942,0.059,0.077,0.0107,17952.526,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-16",12,11.06,2568.88,,0.006,0.001,1094.374,0.059,0.083,0.0112,18414.708,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-17",12,11.53,2764.55,,0.006,0.001,1153.963,0.059,0.082,0.0113,19417.061,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-18",12,10.41,2380.69,,0.005,0.001,1003.935,0.059,0.085,0.0143,16892.633,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-19",12,10.78,2506.08,,0.005,0.001,1047.928,0.059,0.081,0.0143,17635.59,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-20",13,12.03,2827.76,,0.006,0.001,1178.756,0.059,0.09,0.0115,19836.81,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-21",13,12.65,2979.85,,0.006,0.001,1229.9,0.059,0.093,0.0112,20695.54,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-22",12,11.03,2575.42,,0.005,0.001,1078.807,0.059,0.084,0.0123,18156.412,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-23",12,10.49,2402.85,,0.005,0.001,1009.369,0.059,0.088,0.0149,16985.424,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-24",12,11.68,2811.72,,0.006,0.001,1168.916,0.059,0.086,0.0104,19670.388,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-25",12,11.08,2650.32,,0.006,0.001,1104.604,0.059,0.087,0.0125,18585.744,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-26",12,11.07,2622.31,,0.006,0.001,1104.895,0.059,0.083,0.0115,18591.661,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-27",24,24,5943,,0.012,0.001,2436.8,0.059,0.16,0.0078,41003.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-28",16,14.83,3464.52,,0.007,0.001,1446.418,0.0591,0.104,0.0125,24339.789,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-29",17,15.93,3718.57,,0.008,0.001,1557.917,0.059,0.111,0.0106,26214.815,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-30",15,13.9,3336.93,,0.007,0.001,1393.166,0.059,0.098,0.0103,23440.885,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-07-31",16,15.33,3155.09,,0.007,0.001,1349.088,0.059,0.102,0.0106,22698.759,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-01",14,12.42,2856.4,,0.006,0.001,1203.623,0.059,0.093,0.0121,20252.186,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-02",12,10.99,2537.97,,0.005,0.001,1071.342,0.059,0.085,0.0129,18025.991,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-03",12,11,2533.8,,0.005,0.001,1070.356,0.059,0.087,0.0135,18012.22,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-04",12,11.13,2543.72,,0.005,0.001,1073.863,0.059,0.086,0.0123,18069.193,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-05",12,11.75,2758.5,,0.006,0.001,1158.725,0.059,0.091,0.0114,19498.65,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-06",11,9.74,2193.34,,0.005,0.001,922.138,0.059,0.081,0.014,15517.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-07",12,11.6,2618,,0.006,0.001,1104.28,0.059,0.08,0.0112,18582.12,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-08",12,11.07,2585.51,,0.005,0.001,1086.761,0.059,0.084,0.0119,18286.81,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-09",13,11.37,2604.01,,0.006,0.001,1097.017,0.059,0.091,0.0141,18461.172,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-10",12,11.22,2254.59,,0.005,0.001,992.06,0.059,0.087,0.0148,16694.919,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-11",11,10,2296.86,,0.005,0.001,968.284,0.059,0.076,0.0133,16291.851,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-12",12,11.07,2589.23,,0.006,0.001,1092.344,0.059,0.087,0.0125,18382.076,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-13",14,13.88,3462.12,,0.007,0.001,1435.672,0.059,0.106,0.0094,24159.292,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-14",16,14.03,2950.8,,0.006,0.001,1276.353,0.059,0.102,0.0153,21477.395,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-15",24,23.9,5060.7,,0.011,0.001,2113.45,0.059,0.132,0.0073,35566.48,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-16",14,13.67,3092.51,,0.007,0.001,1299.326,0.059,0.088,0.009,21863.68,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-17",24,24,5685,,0.012,0.001,2355.3,0.059,0.154,0.0077,39633.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-18",24,23.87,5067.19,,0.011,0.001,2113.554,0.059,0.131,0.0073,35560.248,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-19",16,15.62,3672.14,,0.008,0.001,1537.926,0.059,0.109,0.0099,25879.56,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-20",17,16.05,3729.43,,0.008,0.001,1559.37,0.059,0.111,0.0098,26241.412,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-21",23,21.09,4905.42,,0.01,0.001,2051.201,0.059,0.142,0.0097,34512.806,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-22",22,20.92,4974.48,,0.01,0.001,2068.37,0.059,0.137,0.0087,34805.992,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-23",24,24,5710,,0.012,0.001,2357.5,0.059,0.147,0.0073,39667.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-24",24,24,6130,,0.013,0.001,2529.9,0.059,0.17,0.008,42575,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-25",24,24,5871,,0.012,0.001,2426.7,0.059,0.163,0.0079,40831.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-26",17,15.93,3670.22,,0.008,0.001,1531.934,0.059,0.105,0.01,25776.085,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-27",16,14.86,3645.78,,0.008,0.001,1516.642,0.059,0.11,0.0116,25520.27,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-28",16,14.93,3380.29,,0.007,0.001,1435.355,0.059,0.099,0.0104,24153.78,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-29",12,10.51,2356.34,,0.005,0.001,998.028,0.059,0.086,0.0138,16793.704,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-30",12,11,2512.21,,0.005,0.001,1061.59,0.059,0.087,0.0141,17862.061,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-08-31",12,11.01,2402.73,,0.005,0.001,1003.105,0.059,0.081,0.0139,16877.458,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-01",12,11.65,2654.25,,0.006,0.001,1122.805,0.059,0.088,0.0123,18893.645,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-02",16,15,3270.53,,0.007,0.001,1384.518,0.059,0.101,0.0111,23294.413,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-03",16,15.23,3524.34,,0.008,0.001,1492.001,0.059,0.112,0.0109,25104.276,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-04",16,15.25,3598.48,,0.008,0.001,1522.49,0.059,0.11,0.0098,25619.061,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-05",17,15.53,3665.2,,0.008,0.001,1557.898,0.059,0.108,0.0106,26208.419,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-06",17,15.12,3590.22,,0.008,0.001,1514.874,0.059,0.115,0.0118,25490.262,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-07",14,12.55,2821.16,,0.006,0.001,1196.066,0.0591,0.089,0.0116,20125.567,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-08",13,12.82,2925.56,,0.006,0.001,1220.396,0.059,0.093,0.0105,20537.618,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-09",24,24,6053,,0.013,0.001,2485.4,0.059,0.165,0.0079,41820.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-10",24,24,6285,,0.013,0.001,2575.9,0.059,0.173,0.008,43344.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-11",24,24,6292,,0.013,0.001,2575.1,0.059,0.171,0.0079,43329.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-12",18,16.95,4246.49,,0.009,0.001,1752.98,0.059,0.124,0.0102,29497.725,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-13",18,16.96,4226.07,,0.009,0.001,1756.64,0.059,0.128,0.0106,29557.458,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-14",24,24,6268,,0.013,0.001,2583.2,0.059,0.175,0.008,43467.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-15",24,24,5859,,0.012,0.001,2467.9,0.059,0.165,0.0079,41530.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-16",24,24,5773,,0.012,0.001,2468.5,0.059,0.166,0.008,41537.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-17",24,24,6013,,0.013,0.001,2559.4,0.059,0.175,0.0081,43061.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-18",24,23.4,5869.6,,0.013,0.001,2499.8,0.059,0.173,0.0088,42063.44,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-20",13,12.58,2721.32,,0.006,0.001,1224.208,0.0591,0.116,0.0175,20600.346,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-21",24,24,5752,,0.013,0.001,2484.9,0.059,0.165,0.0079,41818.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-22",14,12.84,2883.19,,0.006,0.001,1272.754,0.059,0.104,0.0141,21413.575,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-23",14,13.17,2972.03,,0.007,0.001,1315.638,0.059,0.107,0.0132,22138.666,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-24",13,11.85,2759.7,,0.006,0.001,1209.46,0.059,0.102,0.0153,20349.57,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-25",13,12.68,2970.04,,0.007,0.001,1295.98,0.059,0.104,0.0123,21808.852,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-26",13,12,2741.34,,0.006,0.001,1200.402,0.059,0.099,0.0137,20197.791,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-27",15,14.05,3286,,0.007,0.001,1427.09,0.059,0.112,0.0123,24012.945,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-28",24,24,5789,,0.012,0.001,2459.2,0.059,0.164,0.0079,41378.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-29",16,15.48,3583.48,,0.008,0.001,1566.148,0.059,0.12,0.0109,26354.159,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-09-30",15,14.15,3220.07,,0.007,0.001,1420.705,0.059,0.114,0.0132,23908.949,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-01",24,24,6150,,0.013,0.001,2609.3,0.059,0.175,0.008,43909.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-02",24,24,6063,,0.013,0.001,2580.3,0.059,0.172,0.0079,43422.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-03",24,24,6065,,0.013,0.001,2564.8,0.059,0.17,0.0079,43162.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-04",24,24,6040,,0.013,0.001,2541.5,0.059,0.171,0.008,42764.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-05",24,24,6303,,0.013,0.001,2654.7,0.059,0.18,0.008,44670.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-06",24,24,6298,,0.014,0.001,2680.1,0.059,0.179,0.008,45097.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-07",24,24,6085,,0.013,0.001,2580.3,0.059,0.175,0.0081,43423.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-08",24,24,6087,,0.013,0.001,2564.3,0.059,0.173,0.008,43148.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-09",24,24,5922,,0.013,0.001,2500.6,0.059,0.166,0.0079,42074.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-10",19,17.9,4174.2,,0.009,0.001,1803.63,0.059,0.132,0.0117,30350.235,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-11",14,12.83,2941.14,,0.006,0.001,1277.93,0.059,0.099,0.0129,21505.006,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-12",24,24,5835,,0.013,0.001,2487.4,0.059,0.166,0.0079,41858.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-13",12,10.7,2241.1,,0.005,0.001,1018.63,0.059,0.086,0.0134,17140.59,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-15",24,23.3,5684.6,,0.012,0.001,2425.83,0.059,0.18,0.0106,40823.47,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-16",24,24,5945,,0.013,0.001,2522.2,0.059,0.17,0.008,42442.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-17",24,24,5882,,0.013,0.001,2486.7,0.059,0.166,0.0079,41844.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-18",24,24,5601,,0.012,0.001,2377.6,0.059,0.159,0.0079,40006.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-19",24,24,6004,,0.013,0.001,2533,0.059,0.17,0.008,42623.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-20",24,24,5918,,0.013,0.001,2496.7,0.059,0.169,0.008,42009.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-21",24,24,5765,,0.012,0.001,2441.8,0.059,0.164,0.008,41086.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-22",24,24,5792,,0.012,0.001,2453.8,0.059,0.165,0.008,41290.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-23",24,24,5991,,0.013,0.001,2526.9,0.059,0.168,0.0079,42516.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-24",24,24,6116,,0.013,0.001,2576,0.059,0.17,0.0078,43345.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-25",19,18.1,4395.56,,0.01,0.001,1896.049,0.059,0.132,0.0094,31900.572,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-26",24,24,5614,,0.012,0.001,2373.7,0.059,0.159,0.008,39944.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-27",24,24,5614,,0.012,0.001,2400.2,0.059,0.161,0.008,40388.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-28",24,24,5543,,0.012,0.001,2362.3,0.059,0.162,0.0081,39746.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-29",19,17.86,4023.72,,0.009,0.001,1744.314,0.059,0.126,0.0119,29352.02,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-30",19,18.18,4332.73,,0.01,0.001,1886.602,0.059,0.137,0.0103,31745.762,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-10-31",19,18.21,4328.75,,0.01,0.001,1898.096,0.059,0.142,0.0108,31942.918,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-01",19,18.15,4405.33,,0.01,0.001,1959.204,0.059,0.144,0.0107,32966.75,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-02",24,24,6385,,0.014,0.001,2719.6,0.059,0.183,0.008,45765.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-03",24,24,5929,,0.013,0.001,2524.6,0.059,0.168,0.0079,42479.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-04",24,24,5435,,0.012,0.001,2330.3,0.059,0.155,0.0079,39207.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-05",24,24,5761,,0.012,0.001,2445.6,0.059,0.163,0.0079,41146.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-06",24,24,5951,,0.013,0.001,2524.9,0.059,0.171,0.008,42485.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-07",24,24,5639,,0.012,0.001,2405.2,0.059,0.161,0.0079,40473.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-08",16,14.88,3060.1,,0.007,0.001,1360.557,0.059,0.109,0.0134,22891.843,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-09",19,18.6,4122.45,,0.009,0.001,1815.147,0.059,0.132,0.0101,30544.951,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-10",24,24,5391,,0.012,0.001,2362.5,0.059,0.156,0.0078,39755.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-11",24,24,5535,,0.012,0.001,2416,0.059,0.162,0.008,40654.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-12",19,18.26,3932.4,,0.009,0.001,1760.704,0.059,0.133,0.0117,29625.912,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-13",19,17.92,4255.98,,0.01,0.001,1884.682,0.059,0.147,0.0125,31711.017,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-14",18,17.16,3591.94,,0.008,0.001,1603.08,0.059,0.123,0.0112,26976.005,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-15",19,17.88,3765.4,,0.008,0.001,1654.796,0.059,0.127,0.0127,27841.732,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-16",24,24,5407,,0.012,0.001,2320.8,0.059,0.151,0.0077,39056.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-17",18,17.07,4081.03,,0.009,0.001,1752.9,0.059,0.126,0.0091,29493.318,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-18",19,18.17,3825.03,,0.009,0.001,1717.408,0.059,0.127,0.0102,28897.34,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-19",13,12.1,2611.86,,0.006,0.001,1162.186,0.059,0.103,0.0146,19555.455,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-20",19,18.18,3803.66,,0.008,0.001,1682.037,0.059,0.129,0.0113,28301.262,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-21",18,17.63,3890.93,,0.009,0.001,1714.834,0.059,0.127,0.0094,28857.696,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-22",18,17.52,3712.69,,0.008,0.001,1622.996,0.059,0.114,0.0095,27307.472,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-23",18,17.38,3709.7,,0.008,0.001,1620.798,0.059,0.124,0.0122,27272.152,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-24",13,12.11,2682,,0.006,0.001,1189.273,0.059,0.099,0.0143,20011.711,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-25",19,17.43,3752.83,,0.008,0.001,1653.767,0.059,0.128,0.0173,27827.592,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-26",18,17.37,3789.81,,0.008,0.001,1661.259,0.059,0.121,0.012,27952.864,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-27",18,17.15,3410.37,,0.008,0.001,1522.805,0.059,0.116,0.0113,25625.585,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-28",18,17.61,3876.65,,0.009,0.001,1703.387,0.059,0.129,0.0112,28663.334,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-29",18,17.43,4043.89,,0.009,0.001,1773.329,0.059,0.134,0.0107,29839.73,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-11-30",19,18.03,4352.41,,0.01,0.001,1895.426,0.059,0.139,0.0114,31897.483,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-01",19,18.05,3905.75,,0.009,0.001,1723.165,0.059,0.124,0.01,28996.645,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-02",19,18.08,3906.93,,0.009,0.001,1724.264,0.059,0.125,0.0102,29013.681,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-03",19,18,4215.1,,0.009,0.001,1846.72,0.059,0.13,0.0102,31073.87,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-04",24,24,5225,,0.011,0.001,2266.2,0.059,0.151,0.0079,38133.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-05",19,18.13,4383.23,,0.01,0.001,1913.228,0.059,0.14,0.0111,32192.735,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-06",19,18.17,4167.45,,0.009,0.001,1834.742,0.059,0.138,0.0107,30872.616,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-07",24,24,5601,,0.012,0.001,2405.8,0.059,0.16,0.0079,40480.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-08",24,24,5241,,0.011,0.001,2257.1,0.059,0.152,0.008,37981.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-09",1,0.63,94.5,,0,0.001,43.911,0.059,0.006,0.017,739.368,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-13",4,2.83,135.29,,0.001,0.001,138.215,0.059,0.076,0.071,2325.223,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-14",24,24,4977,,0.012,0.001,2337.3,0.059,0.151,0.0076,39324,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-15",15,14.05,2891.69,,0.007,0.001,1296.671,0.059,0.105,0.012,21820.362,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-16",4,2.47,141.08,,0.001,0.001,132.651,0.0593,0.038,0.0448,2232.61,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-17",11,10.12,2024,,0.005,0.001,930.548,0.0591,0.088,0.0195,15658.112,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-18",19,17.57,3863.83,,0.009,0.001,1685.072,0.059,0.122,0.0132,28354.819,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-19",19,18.13,4145.85,,0.009,0.001,1815.921,0.059,0.131,0.0098,30557.506,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-20",19,18.11,4256.05,,0.009,0.001,1852.8,0.059,0.13,0.0095,31176.223,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-21",19,17.78,3839,,0.008,0.001,1675.074,0.059,0.126,0.0097,28188.085,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-22",14,12.88,2724.08,,0.006,0.001,1200.072,0.059,0.095,0.0148,20195.586,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-23",19,17.95,3973.44,,0.009,0.001,1744.261,0.059,0.138,0.0111,29352.838,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-24",24,24,5727,,0.012,0.001,2460.3,0.059,0.162,0.0078,41400.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-25",19,18.1,4150.95,,0.009,0.001,1815.19,0.059,0.131,0.0106,30545.75,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-26",12,11.4,2381.7,,0.005,0.001,1048.46,0.059,0.091,0.0121,17643.69,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-27",13,12.19,2650.72,,0.006,0.001,1182.798,0.059,0.097,0.0133,19901.633,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-28",24,24,6004,,0.013,0.001,2567.1,0.059,0.172,0.008,43192.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-29",19,18.15,3975.06,,0.009,0.001,1756.585,0.059,0.127,0.0103,29557.738,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-30",19,18.15,3935.21,,0.009,0.001,1742.275,0.059,0.129,0.0105,29321.113,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","High Desert Power Project",55518,"CTG3",,"2020-12-31",14,13.24,2850.56,,0.006,0.001,1263.111,0.059,0.103,0.012,21250.566,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-02",2,1.18,39.94,,0,0.001,24.68,0.059,0.007,0.024,415.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-03",6,3.41,144.91,,0,0.001,84.284,0.0593,0.009,0.0298,1416.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-06",5,2.89,77.22,,0,0.001,51.557,0.0592,0.009,0.0204,867.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-07",15,12.64,344.41,,0.001,0.001,222.286,0.0592,0.016,0.0135,3741.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-08",3,1.48,35.74,,0,0.001,24.669,0.059,0.004,0.0203,415.681,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-09",4,2.25,62.27,,0,0.001,40.521,0.059,0.006,0.02,682.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-14",4,2.4,62.05,,0,0.001,41.146,0.059,0.008,0.0188,692.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-15",3,1.16,28.04,,0,0.001,19.288,0.059,0.003,0.0613,325.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-16",2,0.94,24.94,,0,0.001,16.478,0.059,0.004,0.0235,277.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-17",2,1.22,34.33,,0,0.001,22.412,0.0595,0.005,0.0195,376.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-25",2,1.23,35.66,,0,0.001,22.82,0.059,0.005,0.0215,383.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-29",2,1.18,36.1,,0,0.001,22.762,0.0595,0.006,0.0275,382.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-30",5,2.81,72.59,,0,0.001,48.202,0.059,0.007,0.0158,812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-01-31",2,1.2,26.86,,0,0.001,18.71,0.0595,0.004,0.0345,314.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-01",3,1.45,62.6,,0,0.001,36.06,0.059,0.006,0.053,606.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-02",2,1.23,44.46,,0,0.001,26.763,0.059,0.005,0.0185,450.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-03",5,2.61,69.28,,0,0.001,45.705,0.059,0.005,0.0302,770.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-04",5,2.42,74.08,,0,0.001,47.122,0.059,0.008,0.0414,793.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-05",3,1.18,31.4,,0,0.001,20.922,0.059,0.005,0.0567,352.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-11",3,1.22,31.8,,0,0.001,21.098,0.0593,0.005,0.0557,355.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-16",5,2.58,74.61,,0,0.001,48.078,0.0594,0.008,0.045,808.777,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-17",10,7.57,330.38,,0.001,0.001,188.211,0.0593,0.012,0.0197,3166.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-18",11,9.2,414.92,,0.001,0.001,234.624,0.0592,0.015,0.0186,3946.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-23",2,1.45,56.55,,0,0.001,34.075,0.0595,0.007,0.0205,573.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-24",5,2.71,75.43,,0,0.001,49.084,0.0594,0.006,0.0342,826.197,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-25",4,2.42,60.38,,0,0.001,41.238,0.059,0.005,0.014,694.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-26",2,1.48,45.6,,0,0.001,28.786,0.0595,0.006,0.0225,484.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-27",3,1.2,32.47,,0,0.001,21.412,0.059,0.004,0.0593,360.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-01",5,2.67,94.76,,0,0.001,57.546,0.0592,0.009,0.0176,967.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-02",2,1.47,63.21,,0,0.001,36.688,0.059,0.006,0.022,617.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-03",3,1.45,56.3,,0,0.001,33.225,0.059,0.006,0.0317,559.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-08",3,1.18,35.5,,0,0.001,22.642,0.0597,0.005,0.06,380.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-09",2,1.2,42.32,,0,0.001,25.638,0.059,0.005,0.0195,432.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-12",10,6.89,314.12,,0.001,0.001,178.808,0.0592,0.019,0.0291,3007.931,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-14",4,3.2,114.65,,0,0.001,69.565,0.0598,0.009,0.0145,1169.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-15",2,1.22,50.36,,0,0.001,29.468,0.0595,0.005,0.036,495.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-16",5,2.41,65.57,,0,0.001,43.275,0.0594,0.006,0.0386,729.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-21",3,1.7,73.42,,0,0.001,42.888,0.059,0.008,0.0227,722.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-23",2,1.28,39.5,,0,0.001,25.136,0.059,0.006,0.0245,423.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-26",3,1.95,57.35,,0,0.001,36.676,0.0593,0.006,0.0197,617.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-27",2,1.12,32,,0,0.001,21.104,0.059,0.005,0.075,355.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-28",4,2.25,90.89,,0,0.001,53.725,0.059,0.006,0.0213,905.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-29",5,2.37,73.53,,0,0.001,46.607,0.0592,0.006,0.0256,784.479,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-03",3,1.16,38.44,,0,0.001,24.136,0.0593,0.006,0.0593,406.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-04",2,1.2,43.11,,0,0.001,26.373,0.0595,0.005,0.0325,444.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-05",2,1.18,26.81,,0,0.001,18.781,0.059,0.003,0.035,316.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-06",4,2.47,75.15,,0,0.001,48.037,0.0593,0.007,0.0138,807.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-14",2,1.18,27.16,,0,0.001,18.768,0.059,0.005,0.031,316.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-20",4,2.68,96.71,,0,0.001,58.514,0.0593,0.008,0.014,985.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-21",2,1.13,51.47,,0,0.001,29.32,0.0595,0.006,0.076,492.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-22",4,1.31,29.95,,0,0.001,26.853,0.0593,0.003,0.0353,451.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-24",10,8.36,283.08,,0.001,0.001,172.856,0.0593,0.014,0.012,2907.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-25",3,1.92,51.36,,0,0.001,33.996,0.0593,0.004,0.0147,571.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-04-30",1,0.23,0,,0,0.001,1.61,0.06,0.003,0.249,27.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-01",5,2.66,103.97,,0,0.001,61.54,0.059,0.008,0.0168,1036.633,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-02",3,1.38,42.62,,0,0.001,26.914,0.0597,0.005,0.0323,452.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-05",4,2.95,85.34,,0,0.001,54.518,0.0595,0.007,0.0215,917.587,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-06",2,1.2,28.3,,0,0.001,19.6,0.0595,0.003,0.019,329.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-09",3,2.17,88.01,,0,0.001,51.198,0.0593,0.007,0.027,860.991,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-14",5,3.17,145.28,,0,0.001,83.918,0.0594,0.012,0.0444,1413.065,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-16",4,2.95,112.5,,0,0.001,66.798,0.0593,0.008,0.0225,1124.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-19",9,7.22,342.38,,0.001,0.001,195.166,0.059,0.014,0.0243,3285.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-21",4,3.22,100.49,,0,0.001,66.319,0.0593,0.006,0.0208,1115.807,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-23",2,1.18,27.19,,0,0.001,19.037,0.059,0.005,0.021,320.471,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-26",4,2.7,98.42,,0,0.001,64.092,0.0593,0.007,0.0143,1077.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-27",4,2.71,81.75,,0,0.001,54.729,0.0595,0.005,0.0128,920.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-30",4,2.62,77.78,,0,0.001,50.769,0.0593,0.006,0.0168,854.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-08",3,1.47,59.29,,0,0.001,37.861,0.0593,0.008,0.0567,637.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-16",2,1.22,39.3,,0,0.001,26.715,0.059,0.006,0.038,450.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-06-30",2,1.15,44.17,,0,0.001,27.737,0.0595,0.006,0.019,466.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-03",3,1.22,48.64,,0,0.001,31.124,0.0593,0.005,0.0387,523.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-04",2,1.22,48.78,,0,0.001,30.544,0.059,0.004,0.017,514.062,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-05",3,2.22,88.85,,0,0.001,57.163,0.059,0.006,0.0187,961.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-06",3,1.89,76.01,,0,0.001,49.495,0.0593,0.005,0.018,832.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-07",3,1.43,56.9,,0,0.001,37.837,0.0593,0.004,0.022,636.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-09",5,2.93,91.28,,0,0.001,60.649,0.0592,0.007,0.0232,1020.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-10",6,4.4,159.86,,0.001,0.001,105.66,0.059,0.008,0.011,1777.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-11",5,3.93,159.94,,0.001,0.001,102.11,0.0594,0.008,0.01,1718.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-12",4,2.72,111.66,,0,0.001,72.802,0.0593,0.006,0.0125,1224.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-14",3,1.19,39.8,,0,0.001,27.627,0.059,0.006,0.055,464.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-24",2,1.2,36.2,,0,0.001,22.745,0.059,0.005,0.0365,382.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-25",2,1.22,49.02,,0,0.001,28.451,0.059,0.004,0.027,478.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-26",3,2.7,115.85,,0,0.001,66.79,0.059,0.006,0.0107,1123.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-27",3,1.19,46.32,,0,0.001,27.234,0.0593,0.004,0.038,458.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-28",2,1.23,42.83,,0,0.001,26.071,0.0595,0.003,0.0265,439.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-29",3,1.95,72.45,,0,0.001,43.146,0.059,0.005,0.019,726.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-30",3,2.24,89.53,,0,0.001,52.179,0.059,0.004,0.0103,878.214,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-07-31",4,3.7,126.54,,0,0.001,77.014,0.059,0.005,0.0085,1297.007,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-09",3,1.7,48.52,,0,0.001,30.433,0.059,0.005,0.0247,512.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-10",2,1.45,42.63,,0,0.001,26.477,0.0595,0.003,0.0135,445.411,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-12",4,3.18,121.79,,0,0.001,70.796,0.0595,0.007,0.0113,1190.441,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-13",11,8.61,267.66,,0.001,0.001,163.88,0.0593,0.013,0.0177,2759.027,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-14",7,6.48,232.66,,0.001,0.001,136.91,0.0591,0.009,0.0081,2305.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-15",7,5.73,194.5,,0.001,0.001,115.688,0.0593,0.008,0.0093,1947.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-16",2,1.71,39.33,,0,0.001,26.422,0.059,0.002,0.011,445.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-17",8,6.78,198.51,,0.001,0.001,125.463,0.0596,0.008,0.0083,2108.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-18",8,6.58,288,,0.001,0.001,160.928,0.0591,0.011,0.0096,2707.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-19",8,6.7,185.2,,0.001,0.001,116.594,0.0593,0.007,0.0174,1962.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-20",6,4.96,189.99,,0.001,0.001,109.762,0.0592,0.008,0.0087,1847.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-23",3,1.36,30.94,,0,0.0007,20.727,0.0593,0.003,0.01,348.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-24",7,5.75,201.63,,0.001,0.001,119.394,0.0593,0.008,0.0099,2008.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-25",3,1.7,50.1,,0,0.001,31.17,0.059,0.003,0.014,524.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-26",3,1.2,26.08,,0,0.001,17.952,0.0593,0.003,0.0387,301.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-27",7,5.22,186.76,,0.001,0.001,109.37,0.0593,0.008,0.0103,1838.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-28",4,2.22,87.02,,0,0.001,51.278,0.0593,0.005,0.0348,862.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-29",2,1.15,24.8,,0,0.001,17.592,0.059,0.003,0.0155,296.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-08-31",2,0.83,31.2,,0,0.001,18.429,0.0595,0.004,0.0215,309.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-03",2,1.2,27.68,,0,0.001,19.05,0.0595,0.005,0.029,320.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-04",6,4.43,172.05,,0.001,0.001,99.303,0.0592,0.008,0.0117,1672.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-05",11,10.05,384.61,,0.001,0.001,222.58,0.0594,0.013,0.0075,3744.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-06",12,10.54,414.14,,0.001,0.001,238.848,0.0591,0.013,0.016,4018.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-08",2,1.45,58,,0,0.001,33.288,0.059,0.005,0.019,560.407,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-09",10,7.97,262.25,,0.001,0.001,158.054,0.0593,0.011,0.0099,2657.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-14",3,1.22,47.86,,0,0.001,27.636,0.0593,0.005,0.0387,465.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-16",4,2.8,114.1,,0,0.001,64.709,0.0595,0.007,0.011,1088.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-23",2,1.25,35.2,,0,0.001,22.266,0.059,0.004,0.0175,375.499,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-29",2,1.26,43.92,,0,0.001,26.388,0.0595,0.004,0.0145,443.613,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-01",5,3.26,85.14,,0,0.001,55.366,0.0592,0.006,0.0276,932.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-04",2,1.26,35.43,,0,0.001,22.617,0.059,0.005,0.0275,380.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-14",5,3.75,114.8,,0,0.001,72.323,0.059,0.007,0.0124,1218.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-19",6,4.29,132.62,,0,0.001,82.793,0.0595,0.008,0.0147,1391.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-20",2,1.51,49.02,,0,0.001,30.004,0.059,0.004,0.0145,505.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-21",2,1.26,34.54,,0,0.001,22.301,0.059,0.004,0.023,375.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-22",8,6.77,310.34,,0.001,0.001,171.91,0.0591,0.012,0.0093,2892.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-25",2,1.26,42.84,,0,0.001,25.578,0.059,0.006,0.0235,430.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-26",2,1.27,52.07,,0,0.001,28.776,0.059,0.004,0.0165,484.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-01",3,1.48,55.2,,0,0.001,32.644,0.059,0.006,0.0277,549.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-02",2,1.28,27.73,,0,0.001,19.881,0.06,0.003,0.028,333.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-04",2,1.51,38.13,,0,0.001,25.452,0.059,0.004,0.0175,429.045,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-05",6,4.35,144.6,,0,0.001,87.989,0.0592,0.007,0.0108,1481.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-06",4,2.5,68.4,,0,0.001,43.68,0.0593,0.004,0.0175,735.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-09",2,1.28,31.6,,0,0.001,21.469,0.06,0.005,0.037,360.619,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-10",3,2.03,47.94,,0,0.001,33.212,0.0597,0.003,0.0123,557.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-11",4,2.78,60.12,,0,0.001,43.831,0.059,0.004,0.0103,737.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-14",2,1.44,33.12,,0,0.001,22.628,0.0595,0.003,0.02,380.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-16",3,1.28,27.98,,0,0.001,19.898,0.0593,0.003,0.025,335.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-23",6,4.28,145.01,,0,0.001,86.173,0.0593,0.009,0.016,1448.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-29",3,1.5,35.92,,0,0.001,24.77,0.059,0.003,0.0217,417.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-02",1,0.13,0,,0,0.001,0.754,0.059,0.001,0.133,12.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-05",3,0.82,10.4,,0,0.001,9.479,0.059,0.012,0.1767,159.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-11",3,2.01,47.91,,0,0.001,32.161,0.059,0.006,0.0213,541.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-12",2,1.23,31.97,,0,0.001,20.45,0.0595,0.002,0.011,344.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-14",3,1.78,40.74,,0,0.001,28.394,0.059,0.005,0.0213,477.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-15",4,2.88,61.64,,0,0.001,45.844,0.0595,0.003,0.0093,770.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-16",3,1.78,49.49,,0,0.001,31.75,0.0593,0.003,0.0127,534.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Escondido Energy Center, LLC",55538,"CTG1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-24",3,2.08,31.69,,0,0.001,32.427,0.059,0.01,0.0403,546.276,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-12",2,1,14.59,,0,0.001,15.201,0.059,0.007,0.0555,255.799,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-06",3,1.28,18.91,,0,0.001,20.657,0.0597,0.008,0.0453,346.859,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-05-31",1,0.18,2.16,,0,0.001,2.412,0.059,0,0.022,40.554,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-01",1,0.38,3.8,,0,0.001,4.636,0.059,0.002,0.05,78.204,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-17",4,2.15,30.18,,0,0.0008,34.308,0.059,0.004,0.0213,578.328,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-27",10,8.62,139.62,,0.001,0.001,149.08,0.0592,0.01,0.0113,2508.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-30",6,5.13,79.26,,0,0.001,86.562,0.0592,0.007,0.0125,1456.837,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-03",10,8.8,142.44,,0.001,0.001,150.424,0.0595,0.013,0.0119,2528.364,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-14",7,6.07,91.55,,0.001,0.001,100.545,0.0591,0.01,0.0153,1691.873,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-15",4,2.28,33.91,,0,0.001,37.058,0.0595,0.004,0.0235,623.364,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-17",8,6.5,100.2,,0.001,0.001,110.175,0.0595,0.009,0.0143,1853.27,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-18",9,7.46,114.19,,0.001,0.001,128.071,0.0593,0.009,0.009,2155.362,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-28",6,4.42,68.48,,0,0.001,75.77,0.0592,0.007,0.0175,1274.974,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-01",2,1.45,21.19,,0,0.001,23.377,0.059,0.004,0.018,394.018,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-05",9,7.94,122.72,,0.001,0.001,134.918,0.0594,0.012,0.0126,2269.53,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-06",13,9.81,146.78,,0.001,0.001,172.196,0.0591,0.015,0.0168,2899.602,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-07",2,0.64,4.41,,0,0.001,7.681,0.059,0.001,0.028,129.658,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-03",5,3.42,55.06,,0,0.001,54.066,0.0592,0.009,0.0224,909.514,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1A","CS001","2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-24",3,2.08,32.34,,0,0.001,33.194,0.059,0.01,0.0403,558.897,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-12",2,1,14.59,,0,0.001,15.495,0.059,0.007,0.0555,260.915,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-06",3,1.28,19.91,,0,0.001,20.937,0.0593,0.008,0.0453,352.323,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-05-31",1,0.17,2.04,,0,0.001,2.414,0.059,0,0.022,40.681,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-01",1,0.38,3.8,,0,0.001,4.75,0.059,0.002,0.05,79.99,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-17",4,2.15,30.18,,0,0.0008,35.044,0.0593,0.005,0.0213,589.716,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-27",10,8.62,143.62,,0.001,0.001,152.804,0.0593,0.011,0.0113,2571.508,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-30",6,5.13,82.26,,0,0.001,88.514,0.059,0.007,0.0125,1490.382,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-03",10,8.8,144.44,,0.001,0.001,153.076,0.0593,0.013,0.0119,2575.124,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-14",7,6.07,94.55,,0.001,0.001,102.662,0.0591,0.01,0.0153,1727.179,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-15",4,2.28,33.91,,0,0.001,37.81,0.059,0.004,0.0235,637.685,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-17",8,6.5,103.2,,0.001,0.001,112.83,0.0594,0.009,0.0143,1896.685,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-18",9,7.46,114.87,,0.001,0.001,130.322,0.0592,0.009,0.009,2193.55,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-28",6,4.42,68.48,,0,0.001,76.232,0.0592,0.007,0.0175,1282.644,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-01",2,1.45,21.19,,0,0.001,23.589,0.059,0.004,0.018,396.708,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-05",9,7.94,126.54,,0.001,0.001,137.318,0.0591,0.012,0.0126,2313.918,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-06",13,9.81,147.78,,0.001,0.001,174.868,0.0595,0.016,0.0168,2938.365,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-07",2,0.64,4.41,,0,0.001,7.632,0.059,0.001,0.028,128.493,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-03",5,3.42,56.06,,0,0.001,54.726,0.0592,0.009,0.0224,922.302,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Chula Vista Energy Center",55540,"1B","CS001","2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-27",5,3.3,128.85,,0,0.001,69.938,0.059,0.014,0.0298,1176.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-30",2,0.96,33.12,,0,0.001,18.9,0.059,0.006,0.0695,318.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-01-31",8,6.37,254.08,,0.001,0.001,151.686,0.0593,0.027,0.0181,2550.737,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-03",3,1.22,39.66,,0,0.001,25.704,0.0593,0.009,0.0963,433.346,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-25",2,0.95,32.59,,0,0.001,20.377,0.059,0.008,0.078,343.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-26",2,1.22,39.99,,0,0.001,25.621,0.0595,0.007,0.054,430.553,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-01",3,2.07,68.62,,0,0.001,43.28,0.059,0.009,0.0303,728.859,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-12",1,0.08,0.72,,0,0.001,0.8,0.059,0.002,0.273,13.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-13",3,1.57,51.35,,0,0.001,32.962,0.059,0.007,0.0297,555.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-22",2,1.16,35.86,,0,0.001,23.15,0.0595,0.004,0.024,389.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-24",4,3.55,136.55,,0,0.001,83.119,0.0593,0.01,0.016,1398.253,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-25",4,2.3,78.95,,0,0.001,49.198,0.0595,0.007,0.04,827.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-27",4,2.24,73.88,,0,0.001,46.548,0.0593,0.007,0.0525,782.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-28",4,2.22,82.38,,0,0.001,50.364,0.0593,0.009,0.081,846.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-05",4,3,105.37,,0,0.001,65.611,0.0593,0.01,0.0248,1103.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-07",5,3.3,123.63,,0,0.001,74.996,0.0592,0.011,0.0344,1262.091,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-09",1,0.3,0.6,,0,0.001,2.04,0.059,0.005,0.29,34.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-16",3,2.68,100.46,,0,0.001,60.674,0.0593,0.006,0.012,1020.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-21",7,5.6,229.99,,0.001,0.001,137.767,0.0591,0.017,0.0367,2317.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-25",4,2.21,83.44,,0,0.001,50.474,0.0595,0.009,0.0145,848.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-26",5,3.75,151.48,,0,0.001,90.286,0.0592,0.015,0.0598,1518.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-27",4,2.26,79.51,,0,0.001,49.033,0.0595,0.009,0.0558,823.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-28",4,2.26,78.25,,0,0.001,48.564,0.0595,0.008,0.0563,815.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-29",2,1.08,36.18,,0,0.001,22.344,0.059,0.005,0.0215,376.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-11",2,1.3,41.92,,0,0.001,26.312,0.0595,0.007,0.0245,442.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-22",2,0.55,13.45,,0,0.001,8.96,0.06,0.007,0.15,150.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-23",6,2.23,64.37,,0,0.001,42.011,0.0592,0.009,0.0673,706.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-26",2,1.23,40.5,,0,0.001,25.269,0.059,0.006,0.039,425.751,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-03",2,1.22,38.32,,0,0.001,24.808,0.059,0.008,0.0725,417.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-05",3,1.7,57.16,,0,0.001,35.712,0.059,0.006,0.0293,601.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-06",4,2.23,87.96,,0,0.001,52.814,0.0595,0.009,0.0618,887.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-07",3,1.9,75.05,,0,0.001,45.235,0.0593,0.008,0.0373,760.745,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-09",4,2.47,93.86,,0,0.001,56.752,0.0595,0.011,0.0163,954.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-10",6,4.2,170.5,,0.001,0.001,101.62,0.0595,0.015,0.0288,1709.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-11",6,4.5,183.82,,0.001,0.001,109.422,0.0595,0.016,0.0513,1840.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-12",6,4.25,166.84,,0.001,0.001,99.725,0.059,0.015,0.0373,1678.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-13",5,3.5,129.94,,0,0.001,78.844,0.0594,0.012,0.0544,1326.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-14",4,2.23,76.34,,0,0.001,47.357,0.0593,0.008,0.067,796.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-15",3,1.25,41.2,,0,0.001,25.818,0.0593,0.006,0.068,433.837,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-16",3,1.19,41.43,,0,0.001,25.467,0.059,0.006,0.0137,428.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-21",2,1.13,38.3,,0,0.001,23.252,0.059,0.003,0.012,391.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-26",3,2.47,86.44,,0,0.001,53.442,0.0593,0.007,0.0197,899.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-27",5,3.23,115.7,,0,0.001,70.522,0.059,0.011,0.0498,1186.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-28",4,2.23,76.47,,0,0.001,47.26,0.0593,0.007,0.0605,795.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-29",5,3.23,119.24,,0,0.001,72.407,0.0594,0.011,0.062,1219.183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-30",7,6.13,261.15,,0.001,0.001,154.092,0.059,0.021,0.0156,2593.691,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-07-31",7,5.61,214.24,,0.001,0.001,129.334,0.059,0.014,0.0213,2178.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-01",5,3.2,121.18,,0,0.001,73.964,0.0592,0.011,0.0294,1244.543,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-02",4,3.04,104.24,,0,0.001,64.708,0.0593,0.01,0.0168,1089.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-03",4,2.3,77.81,,0,0.001,48.027,0.059,0.009,0.0565,808.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-04",3,1.25,40.29,,0,0.001,25.466,0.0597,0.006,0.0627,427.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-09",2,1.71,57.26,,0,0.001,35.299,0.0595,0.006,0.0205,593.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-10",4,2.25,82.97,,0,0.001,50.439,0.059,0.008,0.0503,849.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-12",4,2.43,95.36,,0,0.001,57.218,0.0595,0.009,0.034,962.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-13",7,5.69,222.77,,0.001,0.001,132.478,0.0591,0.015,0.0146,2230.709,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-14",10,8.23,328.9,,0.001,0.001,195.038,0.0591,0.024,0.0486,3283.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-15",8,6.25,235.85,,0.001,0.001,142.217,0.0591,0.018,0.0319,2392.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-16",7,5.19,181.36,,0.001,0.001,111.13,0.059,0.013,0.0113,1870.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-17",10,8.17,308.06,,0.001,0.001,186.533,0.059,0.025,0.0223,3141.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-18",11,9.45,364.61,,0.001,0.001,220.459,0.0593,0.029,0.0215,3707.333,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-19",12,10.97,405.31,,0.001,0.001,247.579,0.0593,0.03,0.0146,4166.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-20",8,6.2,236.52,,0.001,0.001,143.628,0.0593,0.02,0.0488,2418.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-21",6,4.18,157.95,,0,0.001,96.092,0.0593,0.016,0.015,1617.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-22",5,3.2,109.18,,0,0.001,68.451,0.0596,0.011,0.0134,1151.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-23",4,2.18,73.09,,0,0.001,45.679,0.0595,0.008,0.0285,769.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-24",7,5.95,236.56,,0.001,0.001,141.827,0.0593,0.022,0.0181,2385.949,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-25",7,5.21,192.65,,0.001,0.001,117.664,0.0591,0.019,0.0629,1980.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-26",7,5.18,181.04,,0.001,0.001,112.105,0.0591,0.014,0.0121,1886.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-27",8,6.69,256.91,,0.001,0.001,155.914,0.0591,0.019,0.0159,2622.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-28",4,1.33,44.63,,0,0.001,28.196,0.0595,0.007,0.049,473.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-03",5,3.22,115.28,,0,0.001,71.736,0.0592,0.014,0.0692,1206.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-04",7,5.22,194.46,,0.001,0.001,119.302,0.0591,0.02,0.0507,2007.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-05",7,6.21,247.97,,0.001,0.001,148.491,0.059,0.028,0.0223,2501.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-06",10,8.78,345.02,,0.001,0.001,207.889,0.0593,0.034,0.0214,3498.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-07",5,3.23,109.64,,0,0.001,68.304,0.0592,0.011,0.0638,1149.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-08",5,3.23,110.17,,0,0.001,68.646,0.059,0.011,0.0688,1155.581,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-09",4,2.21,73.73,,0,0.001,46.135,0.0595,0.01,0.0918,776.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-10",4,2.23,74.53,,0,0.001,46.733,0.0593,0.009,0.0715,785.991,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-11",4,2.2,73.52,,0,0.001,45.999,0.0593,0.009,0.0155,774.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-17",2,1.21,40.7,,0,0.001,25.289,0.059,0.006,0.0425,425.854,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-18",4,2.71,97.34,,0,0.001,60.005,0.0598,0.009,0.0195,1008.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-19",4,2.75,107.9,,0,0.001,64.555,0.059,0.013,0.0933,1086.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-21",6,2.71,86,,0,0.001,54.474,0.0592,0.011,0.0618,917.871,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-22",5,3.7,145.26,,0,0.001,86.5,0.0592,0.021,0.0222,1455.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-28",5,3.23,114.24,,0,0.001,70.751,0.0592,0.013,0.0732,1190.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-29",3,1.23,38.17,,0,0.001,24.659,0.0593,0.007,0.122,415.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-09-30",3,1.25,42.1,,0,0.001,26.53,0.0593,0.009,0.0987,446.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-01",3,2,76.25,,0,0.001,46.195,0.0593,0.013,0.0293,778.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-02",2,1.31,41.34,,0,0.001,26.23,0.0595,0.007,0.0285,440.907,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-04",3,1.2,41.72,,0,0.001,26.068,0.0593,0.007,0.0947,438.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-05",2,1.03,32.93,,0,0.001,21.179,0.0595,0.008,0.0295,356.607,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-12",5,3.19,110.17,,0,0.001,69.19,0.0594,0.011,0.0138,1163.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-13",2,1.23,39.19,,0,0.001,25.077,0.059,0.006,0.0405,422.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-14",3,1.95,71.49,,0,0.001,43.951,0.0593,0.007,0.0307,739.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-15",4,3.16,116.18,,0,0.001,71.947,0.059,0.01,0.0193,1210,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-16",4,2.18,73.27,,0,0.001,46.102,0.059,0.008,0.0333,775.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-17",4,2.21,77.52,,0,0.001,48.336,0.0595,0.009,0.1,812.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-20",4,2.18,72.22,,0,0.001,45.772,0.0595,0.009,0.0153,769.147,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-26",2,0.47,12.84,,0,0.001,8.664,0.059,0.005,0.0635,145.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-27",5,2.45,83.98,,0,0.001,52.633,0.0592,0.014,0.0434,885.979,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-29",2,1.2,42.57,,0,0.001,26.439,0.059,0.008,0.0345,444.726,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-02",5,3.15,124.08,,0,0.001,74.983,0.0592,0.011,0.013,1261.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-03",5,3.23,110.04,,0,0.001,69.001,0.059,0.01,0.0636,1162.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-04",4,3.33,115.1,,0,0.001,71.329,0.059,0.01,0.0175,1201.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-05",6,4.73,189.56,,0.001,0.001,113.802,0.0592,0.017,0.0208,1914.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-06",4,2.44,82.2,,0,0.001,50.915,0.0593,0.009,0.0135,857.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-09",4,2.2,74.45,,0,0.001,46.18,0.059,0.009,0.0338,777.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-10",3,2.08,77.42,,0,0.001,46.977,0.059,0.01,0.022,790.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-11",4,2.2,73.56,,0,0.001,45.94,0.0598,0.01,0.0863,771.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-12",4,2.2,73.6,,0,0.001,45.728,0.0593,0.01,0.0783,769.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-16",4,2.23,90.13,,0,0.001,54.033,0.059,0.011,0.0833,909.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-17",4,2.2,73.92,,0,0.001,46.268,0.0593,0.008,0.0705,777.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-22",3,1.73,56.03,,0,0.001,35.584,0.059,0.006,0.0287,599.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-01",2,0.91,32.06,,0,0.001,19.898,0.059,0.005,0.055,335.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-12",3,1.68,64.54,,0,0.001,38.764,0.0593,0.007,0.0263,652.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-14",6,4.59,181.51,,0.001,0.001,107.848,0.0595,0.022,0.0332,1813.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-16",3,1.84,59.54,,0,0.001,38.136,0.0593,0.01,0.1167,642.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-17",10,8.21,338.7,,0.001,0.001,204.421,0.0594,0.022,0.0452,3437.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-27",4,2.78,107.14,,0,0.001,64.69,0.0593,0.012,0.0733,1088.848,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-28",8,7,279.76,,0.001,0.001,166.776,0.0594,0.025,0.0156,2805.896,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-03",3,1.24,40.64,,0,0.001,26.336,0.059,0.01,0.0923,443.568,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-25",2,0.95,34.05,,0,0.001,21.26,0.059,0.011,0.1035,358.39,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-26",2,1.2,40.26,,0,0.001,25.422,0.06,0.007,0.06,427.002,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-01",3,2.1,69.53,,0,0.001,43.648,0.059,0.011,0.0343,735.162,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-10",3,1.03,25.84,,0,0.001,17.943,0.0597,0.013,0.1237,301.352,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-12",3,2.63,90.79,,0,0.001,56.767,0.0593,0.011,0.0267,954.235,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-13",2,1.28,42.28,,0,0.001,26.896,0.0595,0.006,0.0255,451.921,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-24",5,3.79,148.53,,0,0.001,89.908,0.0592,0.013,0.0182,1511.808,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-25",4,2.3,78.78,,0,0.001,49.273,0.0593,0.009,0.042,828.436,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-27",4,2.24,92.48,,0,0.001,54.536,0.0593,0.025,0.183,917.532,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-28",6,3.31,116.81,,0,0.001,72.563,0.0593,0.015,0.0567,1221.327,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-05",3,1.53,46.67,,0,0.001,30.353,0.06,0.007,0.031,509.759,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-07",5,3.3,112.25,,0,0.001,70.131,0.0596,0.012,0.0384,1178.034,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-09",4,2.94,113.12,,0,0.001,68.172,0.0593,0.011,0.0255,1146.866,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-16",3,2.5,87,,0,0.001,53.63,0.059,0.011,0.0283,903.03,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-21",7,5.86,239.07,,0.001,0.001,142.926,0.0593,0.019,0.036,2405.917,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-25",4,2.25,83.64,,0,0.001,50.959,0.0593,0.012,0.076,856.516,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-26",5,3.75,149.6,,0,0.001,89.774,0.0594,0.015,0.046,1510.228,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-27",4,2.28,79.57,,0,0.001,49.248,0.0595,0.01,0.0555,827.931,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-28",4,2.26,77.99,,0,0.001,48.538,0.0595,0.01,0.0568,816.387,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-29",2,1.1,35.8,,0,0.001,22.57,0.0595,0.006,0.0245,379.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-03",4,2.26,81.77,,0,0.001,49.698,0.0593,0.01,0.0465,835.333,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-04",5,3.51,137.74,,0,0.001,82.051,0.0594,0.014,0.039,1379.705,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-09",5,3.28,116.17,,0,0.001,71.673,0.0594,0.013,0.0464,1205.863,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-10",5,3.27,123.69,,0,0.001,74.804,0.059,0.014,0.0566,1258.898,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-11",4,2.23,75.64,,0,0.001,46.724,0.0593,0.012,0.1053,787.339,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-22",4,2.23,76.24,,0,0.001,47.797,0.0593,0.009,0.071,804.643,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-23",3,1.23,39.37,,0,0.001,24.946,0.06,0.007,0.0627,418.963,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-03",3,1.48,49.04,,0,0.001,31.577,0.0593,0.009,0.051,531.718,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-06",4,2.25,86.4,,0,0.001,52.6,0.0595,0.01,0.051,885.21,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-07",3,1.92,75.07,,0,0.001,45.245,0.0593,0.009,0.0437,761,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-09",4,2.47,92.86,,0,0.001,56.348,0.0593,0.012,0.0178,949.271,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-10",6,4.47,179.47,,0.001,0.001,107.167,0.0592,0.018,0.0165,1802.616,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-11",7,5.65,223.66,,0.001,0.001,134.707,0.0593,0.023,0.0353,2266.801,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-12",6,4.25,165.85,,0.001,0.001,99.729,0.0597,0.017,0.042,1676.883,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-13",5,3.5,128.94,,0,0.001,78.77,0.059,0.014,0.055,1325.306,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-14",4,2.23,77.34,,0,0.001,47.66,0.0595,0.009,0.0655,802.068,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-15",3,1.24,40,,0,0.001,25.708,0.06,0.007,0.0693,431.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-16",3,1.2,41.32,,0,0.001,25.446,0.0593,0.007,0.0153,428.754,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-21",3,1.18,37.35,,0,0.001,23.927,0.059,0.007,0.0173,402.657,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-26",3,2.46,87.6,,0,0.001,54.59,0.0593,0.008,0.0187,918.532,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-27",5,3.23,116.6,,0,0.001,71.274,0.0592,0.013,0.0572,1199.656,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-28",4,2.23,76.47,,0,0.001,47.489,0.0595,0.01,0.0693,798.149,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-29",5,3.23,118.37,,0,0.001,72.526,0.0594,0.014,0.0666,1220.597,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-30",10,8.21,347.33,,0.001,0.001,203.406,0.0592,0.033,0.0429,3422.782,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-07-31",10,8.19,303.36,,0.001,0.001,184.973,0.0593,0.026,0.0147,3110.329,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-01",4,2.15,80.14,,0,0.001,48.573,0.06,0.01,0.019,815.998,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-02",5,3.19,112.29,,0,0.001,68.816,0.059,0.011,0.0144,1158.532,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-03",4,2.25,77.35,,0,0.001,47.565,0.059,0.009,0.0538,800.044,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-09",2,1.71,57.26,,0,0.001,35.299,0.0595,0.007,0.0235,593.492,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-10",4,2.25,82.97,,0,0.001,50.39,0.0595,0.01,0.062,847.412,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-12",6,4.74,186.64,,0.001,0.001,112.676,0.0593,0.02,0.0468,1895.208,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-13",7,5.7,221.64,,0.001,0.001,133.682,0.0591,0.02,0.019,2250.212,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-14",18,16.23,617.1,,0.002,0.001,373.447,0.0594,0.052,0.0157,6280.683,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-15",10,8.25,312.9,,0.001,0.001,189.762,0.0591,0.031,0.0325,3192.512,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-16",10,8.25,298.96,,0.001,0.001,182.747,0.0591,0.028,0.0314,3076.024,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-17",10,8.2,307.11,,0.001,0.001,187.614,0.0591,0.029,0.016,3158.419,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-18",12,10.45,396.33,,0.001,0.001,242.164,0.0593,0.034,0.0153,4073.213,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-19",15,13.25,490.7,,0.002,0.001,301.942,0.0592,0.044,0.0159,5081.643,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-20",10,8.21,309.49,,0.001,0.001,188.736,0.0593,0.028,0.0156,3175.349,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-21",8,6.22,238.09,,0.001,0.001,144.092,0.0594,0.024,0.0166,2421.377,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-22",6,4.2,149.18,,0,0.001,92.462,0.0593,0.014,0.0142,1555.081,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-23",6,4.22,150.94,,0,0.001,93.124,0.0593,0.014,0.0137,1567.355,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-24",7,5.95,227.87,,0.001,0.001,138.22,0.0593,0.024,0.0203,2326.642,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-25",6,4.25,155.61,,0,0.001,95.459,0.0592,0.017,0.0532,1606.836,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-26",6,4.21,149.57,,0,0.001,92.442,0.0592,0.014,0.0397,1556.644,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-27",8,6.95,265.96,,0.001,0.001,161.845,0.0591,0.021,0.0156,2724.82,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-28",7,5.2,202.83,,0.001,0.001,122.842,0.0591,0.018,0.0141,2067.654,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-03",3,1.63,55.54,,0,0.001,35.113,0.059,0.008,0.0267,591.137,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-04",6,4.23,157.27,,0,0.001,96.989,0.0592,0.018,0.0622,1633.355,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-05",7,6.23,244.39,,0.001,0.001,147.868,0.0591,0.028,0.023,2488.752,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-06",10,8.53,338.52,,0.001,0.001,205.166,0.0593,0.034,0.0243,3450.032,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-07",7,5.25,187.62,,0.001,0.001,114.661,0.0591,0.02,0.0487,1930.01,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-08",5,3.23,113.07,,0,0.001,69.782,0.059,0.015,0.0748,1176.176,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-09",5,3.2,112.73,,0,0.001,69.309,0.0592,0.016,0.032,1166.647,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-10",4,2.23,76.53,,0,0.001,47.409,0.0595,0.011,0.0955,797.452,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-11",4,2.21,75.49,,0,0.001,46.665,0.0593,0.011,0.0183,784.729,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-16",4,2.25,86.05,,0,0.001,52.515,0.0593,0.012,0.0828,883.355,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-17",4,2.23,77.47,,0,0.001,48.602,0.0598,0.011,0.0838,817.175,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-18",5,3.22,117.28,,0,0.001,71.714,0.059,0.014,0.0578,1206.904,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-19",4,2.75,101.85,,0,0.001,61.75,0.0593,0.011,0.0823,1038.69,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-21",6,4.21,150.65,,0,0.001,93.098,0.059,0.017,0.062,1565.469,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-22",9,5.65,209.01,,0.001,0.001,126.913,0.0593,0.029,0.0416,2135.481,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-23",4,2.23,76.27,,0,0.001,47.373,0.059,0.011,0.083,797.351,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-24",5,3.23,113.17,,0,0.001,69.855,0.0596,0.013,0.059,1174.506,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-28",5,3.23,116.24,,0,0.001,72.383,0.0596,0.013,0.0676,1217.918,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-29",5,3.5,123.46,,0,0.001,76.426,0.0594,0.015,0.065,1286.442,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-09-30",5,3.15,111.08,,0,0.0008,68.283,0.059,0.015,0.03,1149.774,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-01",7,5.25,187.61,,0.001,0.001,115.569,0.0594,0.02,0.0427,1943.516,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-02",7,5.23,187.6,,0.001,0.001,114.657,0.0591,0.019,0.0473,1929.148,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-04",3,1.23,41.74,,0,0.001,26.257,0.059,0.007,0.083,441.777,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-05",5,3.78,143.74,,0,0.001,87.582,0.0592,0.015,0.0218,1473.643,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-06",5,3.25,132.5,,0,0.001,80.14,0.0596,0.015,0.0668,1347.855,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-07",5,3.23,112.94,,0,0.001,70.06,0.0594,0.013,0.0674,1177.49,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-08",4,3.13,110.04,,0,0.001,68.013,0.0593,0.011,0.0183,1145.009,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-12",5,3.2,112.25,,0,0.001,69.731,0.059,0.011,0.0142,1173.881,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-13",6,4.2,150.58,,0,0.001,93.523,0.0593,0.014,0.0142,1573.856,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-14",4,2.71,103.48,,0,0.001,63.023,0.0595,0.013,0.0648,1060.055,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-15",5,3.73,142.64,,0,0.001,87.713,0.0598,0.014,0.0202,1474.021,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-16",6,4.21,149.83,,0,0.001,92.983,0.0592,0.013,0.013,1564.399,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-17",5,3.23,115.74,,0,0.001,72.247,0.0596,0.011,0.0476,1214.404,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-18",5,3.2,126.24,,0,0.001,77.113,0.0594,0.013,0.014,1296.807,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-19",5,3.23,114.84,,0,0.001,71.51,0.0594,0.012,0.0502,1202.561,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-20",5,3.23,111.14,,0,0.001,69.72,0.0596,0.014,0.0668,1172.345,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-21",5,3.23,115.24,,0,0.001,71.013,0.0594,0.013,0.0516,1194.085,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-22",4,2.23,76.37,,0,0.001,48.065,0.0595,0.009,0.0593,808.472,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-23",4,2.23,76.34,,0,0.001,48.089,0.0595,0.009,0.0773,809.777,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-27",3,1.87,66.41,,0,0.001,41.642,0.059,0.014,0.039,700.484,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-28",3,1.56,56.12,,0,0.001,35.008,0.0597,0.009,0.0617,588.426,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-29",5,3.23,115.14,,0,0.001,71.996,0.059,0.013,0.0554,1212.903,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-30",3,1.37,41.58,,0,0.001,27.431,0.0593,0.009,0.1037,461.978,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-04",5,4.51,168.1,,0.001,0.001,104.171,0.059,0.014,0.0156,1754.387,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-05",6,4.7,188.1,,0.001,0.001,113.81,0.0597,0.017,0.0207,1913.06,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-06",4,2.45,85.54,,0,0.001,53.252,0.0593,0.009,0.0138,895.795,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-09",4,2.21,76.49,,0,0.001,47.986,0.0595,0.01,0.0155,806.512,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-10",3,2.08,79.5,,0,0.001,48.704,0.0593,0.01,0.0213,820.21,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-11",4,2.2,75.6,,0,0.001,47.592,0.0598,0.01,0.0855,799.724,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-12",4,2.2,75.52,,0,0.001,47.44,0.0593,0.009,0.0648,797.844,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-16",4,2.25,89.6,,0,0.001,54.445,0.0595,0.012,0.0875,916.77,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-17",4,2.23,76.04,,0,0.001,47.69,0.0593,0.009,0.08,803.022,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-22",3,1.75,57.99,,0,0.001,36.859,0.059,0.007,0.032,619.792,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-01",2,0.92,32.29,,0,0.001,20.327,0.06,0.006,0.0585,341.527,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-12",3,1.7,64.2,,0,0.001,39.406,0.0597,0.009,0.0423,662.652,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-14",6,4.53,178.9,,0.001,0.001,107.697,0.0592,0.02,0.0275,1812.28,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-15",3,2.07,69.76,,0,0.001,44.076,0.0593,0.009,0.0237,742.553,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-16",3,1.85,64.37,,0,0.001,40.727,0.0593,0.011,0.1057,684.458,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-17",12,9.31,366.02,,0.001,0.001,222.983,0.0593,0.03,0.0333,3751.669,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-29",4,2.55,97.5,,0,0.001,57.135,0.059,0.013,0.018,961.805,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-30",8,6.38,255.15,,0.001,0.001,147.297,0.0594,0.021,0.0321,2478.59,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-03",3,1.21,37.68,,0,0.001,24.113,0.0593,0.009,0.184,406.348,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-25",3,0.95,22.44,,0,0.001,15.519,0.06,0.011,0.2603,260.665,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-26",2,1.18,39.12,,0,0.001,24.069,0.059,0.007,0.0635,404.678,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-01",3,2.09,67.13,,0,0.001,41.155,0.0597,0.009,0.031,691.605,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-09",1,0.77,28.49,,0,0.001,17.479,0.059,0.007,0.047,293.986,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-12",3,2.62,85.22,,0,0.001,53.024,0.0593,0.01,0.025,892.784,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-24",3,1.53,45.44,,0,0.001,29.064,0.0593,0.005,0.027,489.474,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-25",5,1.59,23.68,,0,0.001,19.791,0.0594,0.015,0.2148,333.32,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-26",2,0.8,26.4,,0,0.001,16.42,0.0595,0.007,0.0435,276.03,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-27",4,2.23,73.34,,0,0.001,45.472,0.0593,0.008,0.0823,765.36,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-28",4,2.22,80.16,,0,0.001,48.54,0.0593,0.008,0.0568,817.338,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-05",4,3,105.37,,0,0.001,63.811,0.0593,0.01,0.0278,1074.52,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-07",4,2.29,81.7,,0,0.001,49.148,0.0595,0.01,0.0508,826.074,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-09",3,1.7,63.5,,0,0.001,37.5,0.0593,0.008,0.042,630.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-16",3,2.48,84.1,,0,0.001,50.52,0.0593,0.011,0.036,849.714,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-21",7,6.09,249.57,,0.001,0.001,147.353,0.0591,0.018,0.0439,2479.617,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-25",4,2.25,81.64,,0,0.001,49.359,0.0595,0.011,0.1108,829.534,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-26",5,3.73,145.2,,0,0.001,86.642,0.059,0.014,0.0768,1458.348,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-27",4,2.26,78.12,,0,0.001,47.599,0.0593,0.009,0.0595,801.202,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-28",4,2.26,75.12,,0,0.001,46.173,0.0598,0.009,0.059,775.591,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-11",2,1.56,51.15,,0,0.001,31.068,0.059,0.009,0.029,523.512,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-22",4,2.22,76.18,,0,0.001,46.858,0.0595,0.008,0.0565,787.344,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-23",3,1.23,39.37,,0,0.001,24.367,0.0593,0.007,0.1043,409.674,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-26",2,1.21,38.06,,0,0.001,23.716,0.0595,0.006,0.047,398.772,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-03",3,1.45,47.89,,0,0.001,29.635,0.0593,0.008,0.0527,497.927,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-05",3,1.7,55.84,,0,0.001,34.46,0.059,0.007,0.0367,580.268,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-06",4,2.25,84.3,,0,0.001,50.48,0.059,0.01,0.0858,849.84,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-07",3,1.9,71.9,,0,0.001,43.01,0.059,0.008,0.048,723.34,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-09",4,2.67,97.46,,0,0.001,58.847,0.0598,0.013,0.0183,988.401,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-10",6,4.47,174.07,,0.001,0.001,102.426,0.0592,0.016,0.0148,1724.333,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-11",6,4.5,172.94,,0.001,0.001,102.968,0.0597,0.016,0.0528,1730.498,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-12",6,4.5,169.44,,0.001,0.001,100.604,0.0593,0.016,0.0487,1691.846,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-13",5,3.5,126.94,,0,0.001,76.48,0.0592,0.012,0.0532,1285.804,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-14",4,2.23,76.24,,0,0.001,46.122,0.0593,0.01,0.093,775.494,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-15",3,1.25,39.96,,0,0.001,25.059,0.0593,0.007,0.0763,421.945,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-16",3,1.2,38.32,,0,0.001,23.607,0.0597,0.007,0.058,396.88,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-21",3,1.2,37.3,,0,0.001,23.343,0.0593,0.007,0.0157,393.43,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-26",3,2.45,83.83,,0,0.001,51.101,0.059,0.008,0.0233,860.328,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-27",5,3.23,113.5,,0,0.001,68.065,0.059,0.011,0.066,1147.231,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-28",4,2.23,76.37,,0,0.001,46.223,0.0593,0.009,0.0828,778.884,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-29",5,3.23,117.37,,0,0.001,70.28,0.0592,0.013,0.0776,1183.164,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-30",7,6.13,243.06,,0.001,0.001,142.225,0.0591,0.023,0.019,2394.598,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-07-31",7,5.48,202.46,,0.001,0.001,121.036,0.0593,0.019,0.06,2035.638,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-01",5,3.18,115.09,,0,0.001,69.445,0.0598,0.012,0.041,1167.03,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-02",5,3.17,104.96,,0,0.001,64.147,0.0592,0.011,0.0144,1079.826,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-03",4,2.23,76.63,,0,0.001,46.314,0.0598,0.009,0.0783,777.886,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-09",2,1.7,56.92,,0,0.001,33.988,0.059,0.008,0.0275,573.206,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-10",4,2.25,80.85,,0,0.001,48.605,0.0593,0.01,0.0678,818.628,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-12",3,1.57,47.34,,0,0.001,29.766,0.0593,0.011,0.0623,500.465,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-13",7,5.69,202.06,,0.001,0.001,121.544,0.0593,0.017,0.018,2043.918,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-14",10,8.22,310.31,,0.001,0.001,183.597,0.0593,0.027,0.0283,3088.841,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-15",8,6.49,237.18,,0.001,0.001,141.782,0.0594,0.021,0.0451,2384.931,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-16",7,5.21,176.44,,0.001,0.001,106.809,0.0594,0.015,0.0544,1797.942,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-17",10,8.19,290.96,,0.001,0.001,175.735,0.0594,0.024,0.0186,2954.872,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-18",11,9.77,357.91,,0.001,0.001,215.17,0.0593,0.028,0.0257,3619.597,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-19",12,10.99,389.62,,0.001,0.001,236.129,0.0593,0.028,0.0143,3971.546,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-20",8,6.23,226.61,,0.001,0.001,136.176,0.0591,0.022,0.0385,2291.852,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-21",6,4.22,152.95,,0,0.001,92.183,0.0595,0.016,0.0312,1549.821,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-22",5,3.2,106.18,,0,0.001,64.877,0.0592,0.011,0.014,1092.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-23",4,2.17,70.08,,0,0.001,43.161,0.0593,0.008,0.024,726.318,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-24",7,5.95,225.92,,0.001,0.001,134.14,0.0593,0.02,0.0176,2257.38,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-25",7,5.21,188.36,,0.001,0.001,112.83,0.0593,0.018,0.0701,1899.075,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-26",7,5.18,176.09,,0.001,0.001,106.937,0.0594,0.017,0.0337,1798.678,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-27",8,6.69,242.63,,0.001,0.001,145.896,0.0593,0.018,0.0166,2455.751,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-28",5,3.2,120.85,,0,0.001,72.485,0.0592,0.012,0.0404,1220.755,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-03",5,3.22,113.06,,0,0.001,69.106,0.0592,0.014,0.0712,1163.452,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-04",7,5.23,186.44,,0.001,0.001,113.985,0.0593,0.018,0.0589,1917.447,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-05",7,6.23,236.63,,0.001,0.001,140.324,0.0591,0.025,0.0216,2361.786,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-06",10,8.53,333.22,,0.001,0.001,197.122,0.0592,0.03,0.0231,3315.98,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-07",5,3.23,106.61,,0,0.001,64.836,0.0596,0.011,0.086,1089.549,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-08",5,3.23,106.97,,0,0.001,64.88,0.0598,0.011,0.0616,1089.838,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-09",4,2.21,71.73,,0,0.001,43.749,0.059,0.009,0.094,736.639,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-10",4,2.25,72.62,,0,0.001,44.388,0.0595,0.009,0.0813,748.145,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-11",4,2.2,71.32,,0,0.001,43.707,0.0593,0.009,0.0475,735.562,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-19",4,2.73,105.31,,0,0.001,62.398,0.0595,0.011,0.0725,1049.799,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-21",6,2.74,83.6,,0,0.001,52.013,0.0597,0.012,0.0602,873.651,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-23",5,3.73,146.5,,0,0.001,85.693,0.059,0.023,0.0378,1442.836,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-28",5,3.2,106.26,,0,0.001,64.658,0.0596,0.012,0.081,1087.556,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-29",4,2.25,73.55,,0,0.001,45.39,0.0595,0.009,0.104,762.635,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-09-30",3,1.25,42,,0,0.001,25.785,0.059,0.009,0.1287,433.56,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-01",3,2,74.4,,0,0.001,44.34,0.0593,0.009,0.0227,745.915,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-02",2,1.33,39.97,,0,0.001,25.165,0.0595,0.008,0.0345,423.633,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-04",3,1.23,40.74,,0,0.001,25.172,0.0597,0.008,0.095,422.941,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-05",4,2.37,75.4,,0,0.001,46.681,0.0593,0.012,0.038,785.254,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-12",5,3.18,106.04,,0,0.001,65.417,0.059,0.01,0.0134,1102.526,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-13",2,1.25,38.89,,0,0.001,24.482,0.0595,0.006,0.042,411.847,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-14",3,1.95,68.86,,0,0.001,41.856,0.0597,0.008,0.037,703.421,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-15",4,3.18,114.5,,0,0.001,69.859,0.0593,0.01,0.021,1175.332,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-16",5,3.2,105.98,,0,0.001,64.736,0.059,0.011,0.015,1091.395,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-17",5,3.21,109.36,,0,0.001,67.119,0.0592,0.012,0.0606,1129.296,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-20",4,2.23,71.14,,0,0.001,44.042,0.0595,0.01,0.0675,740.107,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-27",2,0.68,22.1,,0,0.001,14.365,0.0595,0.009,0.0985,241.619,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-29",2,0.95,32.93,,0,0.001,20.424,0.059,0.006,0.0495,344.136,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-02",5,3.14,119.96,,0,0.0008,73.528,0.059,0.013,0.0396,1238.174,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-04",4,2.58,85.37,,0,0.001,53.537,0.0593,0.01,0.0458,900.526,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-05",6,4.7,185,,0.001,0.001,111.875,0.0595,0.016,0.0207,1882.045,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-06",4,2.66,87.16,,0,0.001,53.908,0.0593,0.009,0.034,907.078,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-09",3,1.93,61.69,,0,0.001,39.195,0.0597,0.005,0.0223,659.087,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-10",3,1.41,43.73,,0,0.001,27.835,0.0597,0.004,0.0223,468.473,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-16",4,2.2,89.06,,0,0.001,53.516,0.0593,0.01,0.0538,900.243,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-22",4,2.7,88.86,,0,0.001,55.591,0.0593,0.01,0.0348,935.165,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-01",2,1.06,39.5,,0,0.001,24.483,0.0595,0.007,0.065,412.197,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-12",3,1.56,60.02,,0,0.001,36.45,0.0593,0.005,0.022,612.574,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-14",3,0.73,12,,0,0.001,9.879,0.0597,0.013,0.2047,165.835,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-15",9,6.24,227.9,,0.001,0.001,138.738,0.0593,0.024,0.055,2332.894,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-16",3,1.8,56.5,,0,0.001,36.662,0.059,0.011,0.132,616.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-17",13,9.95,405.12,,0.001,0.001,244.057,0.0591,0.029,0.0228,4108.093,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Indigo Generation Facility",55541,"3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-03",6,4.82,186.12,,0.001,0.001,111.892,0.0592,0.015,0.048,1883.644,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-17",2,1.1,35.88,,0,0.001,22.602,0.0595,0.007,0.0385,379.756,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-01-31",2,1.22,40.43,,0,0.001,25.461,0.059,0.009,0.0525,429.194,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-13",5,3.22,116.88,,0,0.001,71.996,0.0594,0.011,0.0936,1211.252,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-14",4,2.23,79.14,,0,0.001,49.227,0.0595,0.008,0.1003,828.92,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-24",1,0.03,0.09,,0,0.001,0.183,0.059,0,0.142,3.099,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-25",11,8.51,343.08,,0.001,0.001,206.061,0.0591,0.032,0.0435,3468.849,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-26",2,1.23,40.39,,0,0.001,25.437,0.059,0.009,0.0495,427.728,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-01",3,1.23,37.56,,0,0.001,23.863,0.059,0.013,0.124,401.686,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-04",1,0.1,1.3,,0,0.001,1.15,0.06,0.002,0.208,19.31,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-05",2,1.13,40.04,,0,0.001,24.648,0.0595,0.004,0.088,414.173,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-06",4,3.6,137,,0,0.001,83.16,0.0595,0.012,0.0198,1399.28,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-07",8,6.09,223.71,,0.001,0.001,137.942,0.0593,0.017,0.0519,2322.431,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-14",2,1.72,64.45,,0,0.001,39.451,0.0595,0.009,0.026,662.937,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-23",2,0.72,21.66,,0,0.001,13.964,0.0595,0.007,0.1215,234.654,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-26",5,4.73,184.53,,0.001,0.001,111.68,0.0592,0.016,0.0172,1879.393,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-28",3,2.47,95.7,,0,0.001,58.465,0.0593,0.011,0.023,983.513,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-29",2,1.22,43.32,,0,0.001,26.966,0.059,0.009,0.039,454.16,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-30",3,2.23,80.45,,0,0.001,49.56,0.0593,0.011,0.0313,833.912,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-05",2,1.17,37.98,,0,0.001,23.556,0.0595,0.006,0.0285,396.819,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-06",5,2.46,82.16,,0,0.001,50.601,0.0594,0.014,0.092,851.72,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-21",2,1.23,42.42,,0,0.001,26.004,0.059,0.006,0.029,438.132,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-24",4,2.48,103.37,,0,0.001,60.182,0.0595,0.008,0.0505,1012.349,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-25",4,2.22,81.06,,0,0.001,48.124,0.059,0.007,0.0753,810.934,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-27",4,2.23,79.43,,0,0.001,48.837,0.0593,0.007,0.073,820.986,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-28",4,2.22,77.98,,0,0.001,47.762,0.0595,0.008,0.095,803.894,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-04",2,1.23,40.59,,0,0.001,25.578,0.059,0.006,0.03,430.029,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-05",3,2.23,80.79,,0,0.001,48.935,0.0593,0.009,0.025,822.49,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-07",3,0.85,15.95,,0,0.001,12.102,0.0593,0.013,0.1477,203.696,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-09",4,2.47,100.83,,0,0.001,59.8,0.0593,0.009,0.0618,1005.907,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-11",3,2.22,82.91,,0,0.001,49.461,0.0593,0.009,0.026,832.74,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-14",1,0.58,17.98,,0,0.001,11.368,0.059,0.011,0.117,191.574,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-16",3,2.22,81.06,,0,0.001,48.948,0.0593,0.009,0.0263,823.552,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-19",8,6.23,258.27,,0.001,0.001,152.357,0.0593,0.017,0.0498,2564.266,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-21",3,2.48,92.08,,0,0.001,55.332,0.059,0.009,0.021,931.792,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-25",4,1.92,68.59,,0,0.001,42.464,0.059,0.013,0.1018,714.702,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-26",5,3.73,159.89,,0,0.001,94.564,0.0592,0.012,0.0462,1593.704,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-27",4,2.23,82.24,,0,0.001,50.59,0.059,0.007,0.0948,851.773,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-28",5,3.23,123.04,,0,0.001,75.137,0.0594,0.01,0.0786,1263.924,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-05-31",6,4.15,156.14,,0,0.001,94.792,0.0593,0.016,0.0505,1594.633,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-08",2,1.21,44.29,,0,0.001,27.706,0.059,0.007,0.0305,466.195,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-20",2,0.63,20.88,,0,0.001,13.481,0.06,0.007,0.1545,226.472,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-22",4,2.21,77.92,,0,0.001,48.409,0.0595,0.007,0.0828,813.923,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-23",3,1.23,40.24,,0,0.001,25.497,0.059,0.005,0.1167,429.142,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-05",3,1.73,56.69,,0,0.001,36.829,0.0593,0.007,0.03,619.541,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-06",3,2.23,92.45,,0,0.001,55.577,0.0593,0.012,0.03,934.46,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-07",3,2.22,93.7,,0,0.001,55.774,0.0597,0.01,0.026,938.133,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-09",4,2.73,108.95,,0,0.001,65.767,0.059,0.01,0.0588,1106.213,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-10",6,4.23,179.14,,0.001,0.001,106.233,0.0593,0.013,0.0688,1788.971,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-11",7,5.98,254.99,,0.001,0.001,151.042,0.0593,0.017,0.0166,2540.006,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-12",6,4.48,188.62,,0.001,0.001,111.546,0.0592,0.013,0.042,1878.524,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-13",5,3.48,134.44,,0,0.001,80.712,0.059,0.011,0.0542,1359.31,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-14",4,2.23,80.14,,0,0.001,48.657,0.0595,0.008,0.0855,818.837,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-15",3,1.22,40.28,,0,0.001,25.08,0.0597,0.005,0.1167,422.544,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-16",3,1.22,40.36,,0,0.001,25.408,0.059,0.005,0.1077,427.704,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-17",3,1.44,53.24,,0,0.001,32.749,0.0593,0.007,0.067,550.579,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-21",3,1.23,41.14,,0,0.001,25.714,0.0593,0.005,0.113,431.995,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-25",2,1.22,40.08,,0,0.001,25.88,0.059,0.007,0.032,435.516,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-26",3,2.71,100.85,,0,0.001,61.463,0.059,0.011,0.022,1035.047,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-27",5,3.21,127.13,,0,0.001,76.354,0.0592,0.01,0.076,1285.549,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-28",5,3.23,119.97,,0,0.001,73.353,0.0592,0.01,0.0796,1234.732,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-29",5,3.21,128.84,,0,0.001,77.861,0.059,0.01,0.078,1309.922,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-30",7,5.48,247.32,,0.001,0.001,145.466,0.059,0.017,0.035,2449.196,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-07-31",7,5.61,250.07,,0.001,0.001,146.534,0.0593,0.018,0.0229,2464.812,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-01",5,3.23,133.04,,0,0.001,78.584,0.0592,0.01,0.0742,1321.731,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-02",5,3.23,120.37,,0,0.001,73.003,0.059,0.01,0.0724,1230.359,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-03",4,2.23,80.27,,0,0.001,48.953,0.059,0.007,0.0838,824.107,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-04",3,1.23,39.94,,0,0.001,24.941,0.0593,0.005,0.108,420.386,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-09",2,1.48,51.8,,0,0.001,31.08,0.059,0.008,0.031,523.392,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-10",3,1.48,54.74,,0,0.001,33.15,0.0593,0.007,0.078,557.51,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-11",3,1.21,40.65,,0,0.001,25.369,0.059,0.005,0.111,427.191,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-12",4,2.47,102.3,,0,0.001,59.504,0.0593,0.009,0.062,1001.235,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-13",9,7.48,311.12,,0.001,0.001,183.583,0.0592,0.022,0.0339,3088.427,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-14",10,8.23,338.24,,0.001,0.001,197.941,0.0594,0.019,0.0369,3329.134,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-15",7,6.22,246.48,,0.001,0.001,146.035,0.0591,0.017,0.017,2458.115,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-16",7,5.22,196.96,,0.001,0.001,117.998,0.0593,0.013,0.0541,1986.078,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-17",10,8.23,336.27,,0.001,0.001,193.014,0.0591,0.02,0.0429,3249.628,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-18",11,9.23,369.87,,0.001,0.001,210.818,0.0595,0.021,0.0364,3547.23,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-19",10,8.48,342.37,,0.001,0.001,197.55,0.0593,0.019,0.0242,3324.387,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-20",7,5.23,216.24,,0.001,0.001,126.8,0.0594,0.014,0.0476,2132.245,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-21",4,2.48,91.96,,0,0.001,55.838,0.059,0.009,0.0608,940.252,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-22",6,4.73,187.57,,0.001,0.001,112.213,0.0592,0.013,0.0327,1888.096,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-23",4,2.48,90.82,,0,0.001,55.278,0.0595,0.008,0.0638,929.082,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-24",7,5.98,244.04,,0.001,0.001,143.776,0.0591,0.016,0.0299,2419.123,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-25",8,6.23,238.84,,0.001,0.001,143.064,0.0593,0.015,0.0449,2408.723,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-26",8,6.2,235.59,,0.001,0.001,140.568,0.0591,0.016,0.0444,2365.996,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-27",8,6.71,272.34,,0.001,0.001,160.886,0.0593,0.019,0.0318,2706.099,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-28",4,3.1,126.91,,0,0.001,74.662,0.0595,0.011,0.0478,1255.399,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-29",2,1.16,37.65,,0,0.001,23.359,0.059,0.008,0.042,393.421,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-03",11,7.94,298.13,,0.001,0.001,179.106,0.0593,0.022,0.052,3014.773,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-04",6,4.47,179.83,,0.001,0.001,106.5,0.0592,0.012,0.037,1792.707,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-05",11,10.85,458,,0.001,0.001,266.175,0.059,0.027,0.0122,4481.375,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-06",14,12.26,512.32,,0.002,0.001,300.263,0.0593,0.034,0.019,5051.136,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-07",5,3.23,119.04,,0,0.001,71.051,0.0592,0.009,0.0684,1195.491,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-08",5,3.23,120.14,,0,0.001,71.655,0.0594,0.009,0.0764,1205.408,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-09",9,7.48,320.24,,0.001,0.001,185.234,0.0592,0.022,0.0337,3118.988,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-10",4,2.23,81.27,,0,0.001,48.537,0.059,0.008,0.091,817.882,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-11",4,2.23,81.37,,0,0.001,48.547,0.0593,0.007,0.0918,818.367,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-12",9,5.17,192.25,,0.001,0.001,115.696,0.0591,0.023,0.0684,1947.048,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-15",12,10.78,433.27,,0.001,0.001,255.46,0.0594,0.027,0.0208,4299.017,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-16",6,4.22,162.18,,0.001,0.001,103.488,0.059,0.012,0.066,1740.128,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-17",7,5.22,196.48,,0.001,0.001,116.818,0.0591,0.013,0.0551,1966.778,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-18",9,7.45,281.84,,0.001,0.001,167.562,0.0591,0.026,0.0236,2819.49,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-19",3,1.73,65.79,,0,0.001,38.706,0.059,0.007,0.0743,652.089,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-21",6,4.18,153.04,,0,0.001,91.008,0.0592,0.01,0.0513,1532.365,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-23",12,8.88,342.94,,0.001,0.001,201.548,0.0593,0.029,0.0545,3391.406,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-28",5,3.23,119.14,,0,0.001,71.768,0.059,0.009,0.0702,1207.454,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-29",6,4.23,165.24,,0,0.001,98.001,0.0592,0.012,0.0605,1649.788,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-09-30",7,5.23,195.84,,0.001,0.001,117.494,0.0593,0.014,0.0593,1978.702,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-01",7,3.7,140.12,,0,0.001,83.439,0.0591,0.014,0.0841,1404.046,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-02",7,5.23,217.04,,0.001,0.001,126.091,0.0593,0.015,0.0619,2122.582,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-04",3,1.23,43.14,,0,0.001,26.491,0.0597,0.005,0.1117,444.928,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-05",3,1.23,43.1,,0,0.001,26.058,0.0597,0.005,0.1257,437.82,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-06",12,10.22,393.3,,0.001,0.001,233.098,0.0594,0.024,0.035,3919.898,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-12",6,4.73,185.89,,0.001,0.001,111.371,0.0592,0.013,0.04,1873.595,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-13",7,5.23,199.04,,0.001,0.001,118.871,0.0594,0.013,0.0579,1998.427,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-14",2,1.5,50.55,,0,0.001,31.32,0.059,0.007,0.0275,527.56,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-15",3,2.47,89.06,,0,0.001,54.155,0.0593,0.008,0.0197,911.044,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-17",9,6.41,231.98,,0.001,0.001,141.815,0.0592,0.02,0.0468,2385.962,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-18",4,2.48,90.59,,0,0.001,54.779,0.0593,0.008,0.0508,922.664,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-19",10,6.63,255.19,,0.001,0.001,153.518,0.0591,0.021,0.0572,2583.189,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-20",14,12.73,478.44,,0.001,0.001,288.281,0.0592,0.03,0.0219,4848.949,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-21",12,10.97,413.5,,0.001,0.001,248.592,0.0591,0.028,0.016,4183.846,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-22",7,6.48,264.17,,0.001,0.001,155.42,0.059,0.017,0.0147,2615.394,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-28",1,0.58,17.98,,0,0.001,11.658,0.059,0.012,0.12,196.33,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-01",3,1.48,49.89,,0,0.001,32.222,0.059,0.006,0.0673,542.534,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-11",4,0.96,21.93,,0,0.001,15.815,0.0595,0.012,0.125,266.231,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-12",2,0.59,17.69,,0,0.001,11.627,0.059,0.011,0.1045,195.966,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-16",4,2.25,84.9,,0,0.001,53.175,0.0593,0.009,0.088,894.735,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-22",3,1.47,50.28,,0,0.001,32.205,0.06,0.006,0.0627,540.851,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-01",4,2.72,98.08,,0,0.001,62.292,0.0598,0.01,0.0538,1046.8,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-02",2,0.75,24.82,,0,0.0005,16.334,0.0595,0.009,0.1935,274.304,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-05",2,1.22,40.78,,0,0.001,26.664,0.059,0.011,0.0675,449.332,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-11",2,1.22,40.43,,0,0.001,25.269,0.0595,0.007,0.0415,424.693,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-15",9,7.23,281.69,,0.001,0.001,168.709,0.0591,0.018,0.051,2839.216,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-16",2,1.23,40.56,,0,0.001,25.695,0.059,0.011,0.0515,432.201,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-18",2,1.23,39.96,,0,0.001,25.146,0.0595,0.009,0.041,423.036,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-03",3,2.23,82.7,,0,0.001,45.087,0.0593,0.012,0.048,757.651,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-17",2,1.12,37.66,,0,0.001,21.014,0.059,0.008,0.044,353.976,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-01-31",4,2.22,80.18,,0,0.001,44.562,0.0593,0.007,0.1113,749.72,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-13",4,2.21,79.92,,0,0.001,43.786,0.0593,0.007,0.1138,737.44,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-25",6,3.83,145.3,,0,0.001,79.542,0.059,0.02,0.062,1338.142,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-26",2,1.21,41.73,,0,0.001,22.825,0.0595,0.008,0.0505,383.752,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-28",2,1.23,37.37,,0,0.001,21.315,0.059,0.008,0.05,359.564,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-01",3,1.96,67.71,,0,0.001,37.284,0.059,0.009,0.048,626.965,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-05",3,1.21,41.08,,0,0.001,23.011,0.0593,0.005,0.1473,386.795,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-06",3,1.25,41.75,,0,0.001,23.4,0.0593,0.006,0.1433,394.17,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-14",5,2.91,104.73,,0,0.001,58.046,0.0592,0.014,0.1092,976.49,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-17",4,2.21,90.47,,0,0.001,48.167,0.0595,0.008,0.122,810.788,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-18",2,0.63,20.23,,0,0.001,11.403,0.0595,0.008,0.105,192.074,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-21",2,1.48,53.56,,0,0.001,29.416,0.059,0.01,0.041,494.892,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-22",3,1.38,47.04,,0,0.001,26.303,0.0597,0.006,0.0837,442.02,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-23",2,1.23,45.48,,0,0.001,25.137,0.0595,0.009,0.0425,422.547,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-26",6,4.97,195.47,,0.001,0.001,106.303,0.0593,0.017,0.0252,1789.545,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-28",3,2.47,96.32,,0,0.001,52.953,0.0593,0.01,0.0247,890.244,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-29",2,1.21,43.51,,0,0.001,24.243,0.059,0.009,0.042,407.654,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-03",2,0.7,20.9,,0,0.001,11.79,0.0595,0.007,0.1605,198.14,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-05",2,1.15,38.85,,0,0.001,21.032,0.059,0.008,0.057,354.613,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-06",9,4.63,162.11,,0,0.001,88.158,0.0594,0.021,0.1097,1483.142,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-21",4,2.73,103.92,,0,0.001,55.715,0.0593,0.012,0.0408,937.382,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-24",3,1.78,73.42,,0,0.001,38.962,0.0593,0.014,0.084,655.36,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-25",3,1.45,50.97,,0,0.001,27.702,0.0593,0.006,0.079,466.483,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-27",3,2.13,80.43,,0,0.001,43.683,0.059,0.005,0.0547,735.49,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-28",4,2.2,80.12,,0,0.001,43.592,0.059,0.005,0.0995,734.668,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-01",2,1.15,42.8,,0,0.001,23.525,0.0595,0.004,0.0775,395.36,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-05",3,1.71,59.92,,0,0.001,33.018,0.0597,0.008,0.0437,554.858,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-07",5,3.21,119.97,,0,0.001,65.233,0.0592,0.008,0.0946,1097.586,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-09",4,2.73,113.27,,0,0.001,59.995,0.0593,0.009,0.0248,1009.701,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-11",3,1.96,74.2,,0,0.001,38.792,0.059,0.008,0.0347,653.973,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-14",1,0.55,17.05,,0,0.001,9.79,0.059,0.011,0.139,164.615,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-16",3,2,73,,0,0.001,39.3,0.059,0.01,0.0407,662.12,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-19",8,6.23,258.14,,0.001,0.001,138.62,0.0594,0.017,0.0663,2331.642,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-21",3,2.48,92.08,,0,0.001,50.272,0.0597,0.009,0.0223,845.032,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-25",4,1.88,68.65,,0,0.001,38.106,0.0595,0.012,0.1203,641.328,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-26",5,3.71,160.46,,0,0.001,86.57,0.0594,0.011,0.057,1456.316,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-27",4,2.71,104.63,,0,0.001,62.305,0.0593,0.012,0.0608,1047.972,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-28",5,3.21,124.08,,0,0.001,67.356,0.0592,0.009,0.0862,1134.875,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-19",2,0.94,26.54,,0,0.001,17.406,0.059,0.028,0.2615,292.718,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-22",4,2.21,79.92,,0,0.001,48.901,0.0593,0.008,0.1083,824.032,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-23",3,1.48,50.84,,0,0.001,31.636,0.0593,0.008,0.0973,531.808,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-05",3,1.71,59.6,,0,0.001,36.894,0.059,0.009,0.0487,620.411,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-06",4,2.75,115.95,,0,0.001,68.71,0.0593,0.013,0.0538,1154.74,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-07",3,2.23,94.1,,0,0.001,55.499,0.059,0.01,0.0283,934.498,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-09",4,2.73,109.25,,0,0.001,64.945,0.059,0.01,0.0703,1093.823,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-10",6,4.23,179.24,,0.001,0.001,105.574,0.0592,0.013,0.0743,1777.891,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-11",7,5.98,254.99,,0.001,0.001,150.116,0.0591,0.018,0.0189,2525.362,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-12",6,4.48,188.02,,0.001,0.001,110.712,0.0592,0.014,0.0545,1863.086,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-13",5,3.22,124.98,,0,0.001,74.906,0.059,0.01,0.0858,1261.606,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-14",4,2.23,79.94,,0,0.001,48.451,0.0593,0.008,0.1095,815.177,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-15",3,1.22,41.28,,0,0.001,25.512,0.0593,0.006,0.1283,429.18,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-16",3,1.22,41.28,,0,0.001,25.43,0.0593,0.006,0.137,427.832,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-17",3,1.45,52.92,,0,0.001,32.452,0.0593,0.008,0.107,545.481,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-21",3,1.23,41.04,,0,0.001,25.797,0.059,0.005,0.1347,434.992,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-25",2,1.22,41.3,,0,0.001,25.513,0.059,0.008,0.041,430.218,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-26",3,2.73,102.4,,0,0.001,61.262,0.0593,0.012,0.0237,1030.007,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-27",5,3.23,126.14,,0,0.001,75.634,0.059,0.011,0.089,1273.447,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-28",5,3.23,120.14,,0,0.001,73.127,0.0594,0.01,0.0906,1230.528,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-29",5,3.23,128.87,,0,0.001,77.296,0.0592,0.011,0.0916,1301.63,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-30",7,5.23,237.63,,0.001,0.001,138.873,0.0594,0.017,0.062,2336.26,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-07-31",6,5.24,236.88,,0.001,0.001,138.698,0.059,0.02,0.0207,2334.384,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-01",5,3.23,133.24,,0,0.001,78.754,0.0598,0.011,0.0884,1323.302,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-02",5,3.23,120.37,,0,0.001,72.9,0.0592,0.01,0.0802,1226.6,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-03",4,2.48,89.74,,0,0.001,54.032,0.059,0.009,0.0723,909.628,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-04",3,1.23,40.74,,0,0.001,25.144,0.0593,0.006,0.1437,423.003,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-09",2,1.48,51.2,,0,0.001,31.168,0.0595,0.01,0.04,523.876,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-10",3,1.23,45.17,,0,0.001,27.123,0.0593,0.005,0.1303,456.156,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-11",3,1.23,42.17,,0,0.001,25.716,0.0593,0.006,0.136,433.392,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-12",4,2.48,102.12,,0,0.001,59.338,0.0595,0.008,0.0715,997.894,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-13",8,6.98,281.77,,0.001,0.001,166.241,0.059,0.02,0.0325,2798.832,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-14",10,8.21,335.68,,0.001,0.001,196.189,0.0591,0.022,0.0524,3301.552,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-15",7,6.22,246.33,,0.001,0.001,145.205,0.059,0.017,0.0177,2443.211,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-16",6,4.23,158.17,,0,0.001,93.91,0.0592,0.011,0.0752,1581.624,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-17",11,9.23,373.17,,0.001,0.001,214.697,0.0591,0.024,0.0447,3613.423,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-18",11,9.23,372.14,,0.001,0.001,210.555,0.0592,0.023,0.0438,3543.835,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-19",10,8.48,341.89,,0.001,0.001,196.902,0.0592,0.021,0.0285,3313.316,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-20",7,5.23,215.24,,0.001,0.001,126.984,0.0593,0.015,0.0614,2136.202,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-21",4,2.23,80.97,,0,0.001,49.056,0.0595,0.008,0.1073,824.836,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-22",6,4.73,189.57,,0.001,0.001,112.447,0.059,0.015,0.0365,1891.803,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-23",4,2.48,91.02,,0,0.001,54.75,0.0595,0.008,0.066,921.498,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-24",8,6.73,272.37,,0.001,0.001,160.38,0.0591,0.016,0.0231,2699.56,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-25",8,6.23,239.07,,0.001,0.001,141.727,0.0593,0.015,0.0421,2384.264,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-26",8,6.23,235.94,,0.001,0.001,140.071,0.0594,0.015,0.0453,2355.972,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-27",8,6.24,235.87,,0.001,0.001,139.995,0.0591,0.021,0.0255,2357.445,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-28",4,3.1,124.94,,0,0.001,73.609,0.0595,0.009,0.0345,1238.44,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-29",2,1.16,38.28,,0,0.001,23.601,0.0595,0.006,0.031,396.587,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-03",6,2.95,97.5,,0,0.001,60.702,0.0592,0.018,0.1013,1021.779,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-04",4,1.12,30.22,,0,0.001,20.15,0.0595,0.015,0.1293,338.85,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-05",11,10.85,468,,0.001,0.001,270.545,0.059,0.029,0.013,4552.65,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-06",14,12.51,515.84,,0.002,0.001,302.585,0.0591,0.038,0.019,5093.884,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-07",5,3.2,118.24,,0,0.001,70.487,0.059,0.01,0.0816,1185.62,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-08",7,4.45,164.21,,0,0.001,98.329,0.0593,0.017,0.0649,1654.157,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-09",13,11.71,510.24,,0.001,0.001,293.275,0.0592,0.035,0.0265,4934.95,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-10",4,2.23,81.27,,0,0.001,48.55,0.0595,0.008,0.1023,818.324,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-11",4,2.22,81.28,,0,0.001,48.692,0.059,0.007,0.0885,820.054,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-16",1,0.22,0,,0,0.001,1.474,0.06,0.003,0.227,24.706,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-17",7,4.73,176.02,,0,0.0009,95.006,0.0593,0.023,0.0921,1598.948,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-18",2,1.23,43.68,,0,0.001,23.931,0.059,0.01,0.0505,403.146,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-19",3,1.73,65.42,,0,0.001,35.341,0.0593,0.007,0.0913,595.275,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-21",4,2.23,82.37,,0,0.001,44.589,0.059,0.007,0.1003,750.935,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-23",10,8.23,329.37,,0.001,0.001,174.476,0.0592,0.019,0.0448,2936.692,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-28",7,3.82,142.63,,0,0.001,77.433,0.0596,0.016,0.1116,1301.986,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-29",6,4.23,167.37,,0,0.001,90.399,0.0592,0.011,0.0673,1521.63,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-09-30",6,4.21,163.92,,0,0.001,89.413,0.0592,0.012,0.0842,1505.195,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-01",7,3.44,129.35,,0,0.001,71.418,0.0594,0.013,0.1361,1202.034,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-04",5,2.46,92.17,,0,0.001,50.318,0.0592,0.015,0.0938,846.633,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-05",7,6.45,264.73,,0.001,0.001,143.099,0.0594,0.026,0.0226,2406.044,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-06",10,8.21,327.21,,0.001,0.001,177.016,0.0592,0.02,0.0494,2978.537,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-12",8,6.46,257.98,,0.001,0.001,140.176,0.0593,0.017,0.0456,2357.422,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-13",6,3.14,108.31,,0,0.001,66.017,0.059,0.025,0.1042,1111.639,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-14",2,1.5,52.9,,0,0.001,31.77,0.0595,0.009,0.034,534.235,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-15",5,2.43,85.34,,0,0.001,51.801,0.059,0.015,0.0694,872.044,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-17",6,4.23,161.64,,0,0.001,94.657,0.0593,0.013,0.0793,1592.96,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-18",5,3.66,142.53,,0,0.001,84.065,0.059,0.012,0.0618,1415.695,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-19",4,2.23,87.17,,0,0.001,51.266,0.0595,0.009,0.1273,862.157,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-22",6,4.48,180.89,,0.001,0.001,105.385,0.0593,0.014,0.0507,1772.746,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-28",2,1.05,30.85,,0,0.001,25.327,0.0595,0.022,0.1025,426.453,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-01",3,1.48,51.02,,0,0.001,31.26,0.059,0.007,0.0847,525.988,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-11",1,0.68,23.12,,0,0.001,14.144,0.059,0.01,0.081,238.408,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-16",4,2.23,85.79,,0,0.001,50.453,0.0595,0.008,0.108,849.897,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-22",3,1.73,61.57,,0,0.001,37.2,0.0593,0.008,0.0377,625.537,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-29",3,1.5,50.36,,0,0.001,31.11,0.0597,0.008,0.1413,522.672,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-01",5,3.23,120.37,,0,0.001,71.892,0.0596,0.011,0.1032,1209.711,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-02",2,0.75,24.82,,0,0.0005,15.533,0.0595,0.011,0.246,261.543,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-05",3,1.73,61.04,,0,0.001,37.2,0.0593,0.011,0.0907,625.35,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-11",2,1.23,42,,0,0.001,25.129,0.059,0.009,0.0465,422.642,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-15",9,7.25,286.9,,0.001,0.001,169,0.0591,0.019,0.0551,2844.845,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-16",2,1.23,41.19,,0,0.001,25.02,0.059,0.01,0.0495,421.596,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Larkspur Energy Faciity",55542,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas","Diesel Oil","Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-16",3,1.35,31.59,,0,0.001,22.284,0.059,0.005,0.0643,375.457,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-02",3,1.4,28.5,,0,0.001,21.31,0.059,0.007,0.1143,358.9,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-26",3,1.77,42.72,,0,0.001,30.338,0.0593,0.01,0.0527,510.435,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-05",3,1.58,33.55,,0,0.001,24.411,0.059,0.007,0.111,411.269,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-14",5,4.34,150.36,,0,0.001,94.317,0.0594,0.011,0.0208,1587.063,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-21",1,0.32,3.84,,0,0.001,3.648,0.06,0.004,0.117,61.184,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-08",2,1.24,23.56,,0,0.001,17.918,0.059,0.007,0.0485,301.94,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-09",4,2.84,81.22,,0,0.001,54.117,0.059,0.009,0.031,911.43,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-18",11,7.78,166.36,,0.001,0.001,120.879,0.0594,0.017,0.0551,2033.741,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-19",4,2.37,48.73,,0,0.001,36.36,0.0593,0.007,0.07,612.513,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-20",5,3.34,69.88,,0,0.001,52.07,0.0596,0.008,0.058,875.08,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-21",9,7.68,346.59,,0.001,0.001,204.666,0.059,0.017,0.0242,3445.376,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-22",5,3.52,74.02,,0,0.001,54.955,0.0594,0.008,0.0364,924.842,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-23",5,3.29,69.15,,0,0.001,51.435,0.0592,0.009,0.0634,865.533,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-24",6,4.4,95.52,,0,0.001,69.36,0.0597,0.009,0.0457,1166.14,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-25",8,6.64,154.43,,0.001,0.001,108.139,0.0593,0.011,0.0224,1821.325,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-26",8,7.02,254.35,,0.001,0.001,158.154,0.0595,0.014,0.0241,2660.088,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-27",9,8.37,317.97,,0.001,0.001,195.318,0.0592,0.015,0.0107,3287.269,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-28",3,1.43,29.65,,0,0.001,21.595,0.0593,0.004,0.0603,364.3,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-30",5,3.3,69.18,,0,0.001,51.63,0.0596,0.006,0.04,867.588,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-02",3,0.56,7.92,,0,0.001,7.096,0.0593,0.007,0.1,119.235,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-03",5,3.6,93,,0,0.001,63.084,0.059,0.008,0.0418,1061.608,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-04",6,5.22,116.14,,0,0.001,81.933,0.0592,0.009,0.0162,1378.841,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-09",5,3.55,78.17,,0,0.001,55.98,0.059,0.007,0.0338,942.841,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-10",7,4.81,135.4,,0,0.001,90.78,0.0593,0.023,0.0553,1528.128,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-11",5,3.55,83.72,,0,0.001,58.178,0.0592,0.009,0.0396,979.246,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-14",3,1.27,25.73,,0,0.001,19.079,0.0593,0.007,0.1,321.13,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-22",5,3.39,62.03,,0,0.001,48.094,0.0592,0.006,0.0484,810.289,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-23",13,11.3,321.8,,0.001,0.001,213.215,0.0591,0.02,0.0237,3590.956,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-09",3,2,55.48,,0,0.001,36.654,0.0593,0.006,0.032,617.042,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-10",3,1.37,27.85,,0,0.001,20.421,0.059,0.006,0.0827,344.3,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-11",5,4.07,145.03,,0,0.001,89.503,0.0592,0.011,0.0242,1506.015,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-12",5,3.67,111.86,,0,0.001,72.001,0.0592,0.01,0.0334,1212.1,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-13",5,2.55,50.6,,0,0.001,37.687,0.0598,0.006,0.0478,634.058,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-15",3,1.39,26.68,,0,0.001,20.345,0.0597,0.005,0.0763,342.369,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-20",3,1.3,25.3,,0,0.001,19.082,0.059,0.005,0.0807,320.962,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-21",4,2.42,50.58,,0,0.001,36.794,0.0593,0.006,0.0593,619.352,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-26",3,2.25,69.69,,0,0.001,44.534,0.0593,0.008,0.0267,749.438,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-27",5,3.42,72.18,,0,0.001,52.822,0.0596,0.008,0.0518,887.464,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-28",5,3.4,72.24,,0,0.001,52.24,0.059,0.008,0.053,880.664,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-29",6,4.42,96.18,,0,0.001,68.71,0.0592,0.009,0.0433,1157.166,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-30",6,4.97,160.08,,0.001,0.001,101.763,0.0592,0.011,0.0238,1713.754,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-07-31",6,4.3,90.36,,0,0.001,65.984,0.0597,0.008,0.044,1109.89,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-01",3,2.13,43.82,,0,0.001,32.312,0.0593,0.007,0.0553,543.683,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-02",5,3.25,69.3,,0,0.001,50.361,0.0596,0.008,0.0606,845.546,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-03",4,2.3,48.18,,0,0.001,35.076,0.0595,0.007,0.0693,589.226,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-09",2,1.31,26.35,,0,0.001,19.448,0.0595,0.006,0.035,326.877,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-10",3,1.73,35.12,,0,0.001,26.069,0.0597,0.009,0.0733,438.064,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-11",3,2.23,45.37,,0,0.001,33.231,0.059,0.012,0.0503,560.1,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-12",4,2.4,64.68,,0,0.001,43.112,0.0593,0.011,0.078,726.78,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-13",10,7.77,271.11,,0.001,0.001,168.299,0.0593,0.017,0.0203,2831.386,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-14",11,10.44,317.78,,0.001,0.001,203.582,0.0592,0.017,0.0115,3425.898,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-15",10,9.72,368.85,,0.001,0.001,223.706,0.0593,0.015,0.0086,3764.384,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-16",10,8.02,221.93,,0.001,0.001,146.813,0.0595,0.013,0.0152,2469.357,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-17",14,13.15,362.4,,0.001,0.001,240.125,0.0593,0.016,0.0084,4039.165,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-18",14,12.53,310.33,,0.001,0.001,211.867,0.0592,0.013,0.0111,3565.644,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-19",9,7.38,171.6,,0.001,0.001,119.882,0.0593,0.01,0.0371,2016.878,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-20",11,8.65,189.62,,0.001,0.001,133.751,0.0594,0.014,0.0384,2252.32,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-21",7,3.56,74.64,,0,0.001,53.517,0.0593,0.012,0.0749,900.954,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-22",6,2.55,57.35,,0,0.001,40.514,0.0595,0.011,0.0865,681.62,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-24",7,5.9,139.54,,0,0.001,96.28,0.059,0.01,0.0243,1620.724,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-25",6,3.56,75.76,,0,0.001,54.272,0.0592,0.01,0.0657,914.11,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-26",22,19.38,427,,0.002,0.001,303.12,0.0594,0.018,0.0245,5100.55,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-27",20,17.56,383.6,,0.001,0.001,271.988,0.0592,0.02,0.0229,4580.414,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-28",13,12.13,273.69,,0.001,0.001,191.886,0.0595,0.012,0.0149,3226.967,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-29",15,12.68,278.19,,0.001,0.001,196.842,0.0592,0.017,0.0261,3314.626,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-30",13,10.37,224.65,,0.001,0.001,160.32,0.0593,0.014,0.0333,2698.67,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-08-31",14,12.3,270.18,,0.001,0.001,192,0.0591,0.014,0.0222,3234.998,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-01",15,13.3,292.3,,0.001,0.001,208.318,0.0597,0.015,0.0209,3502.054,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-02",12,10.3,225.18,,0.001,0.001,160.56,0.0595,0.013,0.0248,2699.252,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-03",13,12.3,276.4,,0.001,0.001,196.09,0.0593,0.012,0.0121,3298.62,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-04",18,14.62,320.42,,0.001,0.001,228.117,0.0593,0.03,0.0357,3838.147,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-05",12,9.93,222.88,,0.001,0.001,156.325,0.0593,0.013,0.0283,2630.168,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-06",9,6.73,218.21,,0.001,0.001,138.1,0.0592,0.013,0.0313,2324.269,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-07",7,5.21,122.77,,0,0.001,84.706,0.0594,0.01,0.0446,1424.234,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-08",4,2.25,48.17,,0,0.001,34.22,0.059,0.005,0.0525,577.064,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-09",14,10.69,228.29,,0.001,0.001,165.764,0.0594,0.015,0.0301,2789.363,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-10",3,1.29,24.86,,0,0.001,19.102,0.0593,0.005,0.0683,320.75,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-14",2,1.2,22.2,,0,0.001,17.04,0.0595,0.005,0.034,286.8,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-15",3,1.33,25.88,,0,0.001,19.33,0.0597,0.005,0.081,324.585,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-16",4,2.28,47.2,,0,0.001,34.288,0.059,0.005,0.0658,577.368,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-17",4,2.88,67.26,,0,0.001,47.262,0.0593,0.006,0.0485,797.08,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-18",2,1.37,26.78,,0,0.001,19.979,0.059,0.006,0.0345,336.952,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-19",6,4.27,92.73,,0,0.001,66.18,0.0592,0.006,0.0408,1114.616,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-20",2,1.32,24.92,,0,0.001,19.171,0.059,0.005,0.0305,322.528,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-21",2,1.42,27.78,,0,0.001,20.564,0.0595,0.006,0.032,345.692,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-28",5,3.78,80.28,,0,0.001,57.36,0.059,0.008,0.0372,967.096,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-29",5,3.3,69.18,,0,0.001,49.882,0.0592,0.007,0.0518,840.128,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-09-30",7,5.53,118.3,,0,0.001,84.925,0.0594,0.008,0.0256,1429.678,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-01",5,4.15,96.4,,0,0.001,67.9,0.0594,0.007,0.0168,1142.31,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-02",6,4.3,91.52,,0,0.001,66.198,0.0593,0.006,0.0463,1113.104,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-03",4,2.32,54.84,,0,0.001,38.144,0.059,0.005,0.0635,642.466,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-04",1,0.08,0,,0,0.001,0.52,0.059,0.001,0.216,8.744,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-09",1,0.63,11.34,,0,0.001,8.631,0.059,0.006,0.078,145.089,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-10",2,1.32,30.36,,0,0.001,21.337,0.059,0.007,0.0425,359.136,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-12",15,11.66,249.1,,0.001,0.001,177.638,0.0593,0.018,0.0335,2988.25,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-13",16,11.94,251.42,,0.001,0.001,180.048,0.0591,0.019,0.0418,3033.941,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-14",16,12.73,276.02,,0.001,0.001,197.724,0.0593,0.016,0.0301,3326.49,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-15",13,10.23,237.83,,0.001,0.001,165.403,0.0593,0.016,0.0283,2783.631,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-16",19,15.84,347.82,,0.001,0.001,248.295,0.0594,0.02,0.0247,4178.802,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-17",11,7.71,164.61,,0.001,0.001,117.931,0.0593,0.013,0.0368,1984.64,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-18",10,7.67,164.03,,0.001,0.001,117.861,0.0593,0.01,0.0259,1984.179,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-19",13,9.69,219.52,,0.001,0.001,155.332,0.0593,0.014,0.0293,2614.347,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-20",11,9.34,204.22,,0.001,0.001,146.47,0.0595,0.011,0.0205,2462.908,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-21",3,2.34,49.72,,0,0.001,36.674,0.0597,0.005,0.019,616.068,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-22",4,3.04,63.8,,0,0.001,45.804,0.0593,0.007,0.0353,770.528,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-27",2,1.35,43.4,,0,0.001,27.435,0.0595,0.008,0.0335,461.325,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-02",5,3.42,73.86,,0,0.001,53.65,0.0594,0.007,0.046,902.246,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-04",6,5.25,125.62,,0,0.001,87.948,0.0592,0.007,0.0098,1482.184,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-05",6,5.07,118.42,,0,0.001,83.751,0.0597,0.006,0.012,1407.785,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-06",4,3.17,68.64,,0,0.001,49.198,0.0593,0.007,0.0225,828.044,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-09",3,2.15,42.74,,0,0.001,32.599,0.0593,0.005,0.0213,548.134,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-10",4,2.35,48.35,,0,0.001,35.425,0.0593,0.006,0.0625,595.805,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-11",4,3.17,66,,0,0.001,48.866,0.0593,0.007,0.0223,822.355,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-15",3,2.55,104.73,,0,0.001,62.892,0.0593,0.01,0.019,1057.509,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-16",4,2.64,60.4,,0,0.001,42.944,0.0593,0.008,0.0513,723.112,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-17",5,3.47,73.13,,0,0.001,53.351,0.0594,0.008,0.0408,899,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-22",2,1.55,30.13,,0,0.001,23.057,0.0595,0.007,0.0365,387.743,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-29",3,1.34,26.1,,0,0.001,19.814,0.0593,0.007,0.091,332.686,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-11-30",4,3.63,98.75,,0,0.001,66.882,0.0595,0.007,0.0148,1124.435,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-01",7,4.44,119.27,,0,0.001,81.268,0.0591,0.012,0.0301,1367.934,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-02",4,2.9,63.03,,0,0.001,45.914,0.059,0.005,0.0208,773.97,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-03",4,3.67,127.52,,0,0.001,80.622,0.0593,0.009,0.014,1356.559,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-04",7,6.03,211.34,,0.001,0.001,133.971,0.0593,0.013,0.0133,2253.945,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-05",4,2.9,58.08,,0,0.001,43.928,0.0595,0.005,0.03,739.71,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-06",3,2,43.18,,0,0.001,31.876,0.0597,0.006,0.0257,536.074,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-07",5,4.17,105.72,,0,0.001,73.532,0.0594,0.008,0.0168,1236.218,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-09",6,4.71,99.48,,0,0.001,73.554,0.0593,0.019,0.0345,1237.282,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-11",4,3.42,142.36,,0,0.001,86.496,0.0593,0.009,0.014,1455.798,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-12",7,6.17,281.86,,0.001,0.001,167.54,0.0591,0.014,0.0136,2819.86,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-13",6,3.82,130.66,,0,0.001,83.498,0.0592,0.012,0.0332,1406.508,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-14",5,4.22,96.75,,0,0.001,69.31,0.0592,0.008,0.0206,1167.556,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-15",7,5.85,175.89,,0.001,0.001,115.524,0.0594,0.009,0.0154,1943.424,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-16",10,8.47,279.39,,0.001,0.001,179.155,0.0592,0.017,0.0136,3015.803,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-27",4,3.12,65.65,,0,0.001,48.376,0.0593,0.006,0.0215,813.429,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-28",2,0.6,7.2,,0,0.001,6.99,0.0595,0.007,0.1275,117.6,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Creed Energy Center",55625,"UNIT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-16",3,1.35,27.94,,0,0.001,19.526,0.059,0.007,0.123,328.681,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-02",3,1.38,27.7,,0,0.001,20.624,0.059,0.007,0.1117,347.98,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-26",3,1.77,42.32,,0,0.001,30.409,0.059,0.009,0.0487,512.553,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-03",2,1.64,34.44,,0,0.001,25.728,0.059,0.01,0.05,433.368,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-14",5,4.32,160.33,,0,0.001,97.528,0.0592,0.013,0.0236,1640.95,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-17",2,1.35,27.11,,0,0.001,19.63,0.059,0.007,0.043,330.51,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-08",3,0.51,3.54,,0,0.001,5.629,0.0593,0.021,0.425,94.776,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-09",4,2.59,77.44,,0,0.001,51.73,0.0595,0.012,0.0553,869.888,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-14",2,1.72,35.32,,0,0.001,27.544,0.059,0.018,0.079,463.432,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-18",8,4.56,89.98,,0,0.001,70.391,0.0594,0.014,0.0865,1183.843,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-19",9,7.15,299.4,,0.001,0.001,180.16,0.0593,0.017,0.0643,3032.338,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-20",5,3.35,70.04,,0,0.001,53.757,0.059,0.008,0.0618,904.974,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-21",5,3.3,69.18,,0,0.001,53.312,0.0592,0.008,0.064,897.276,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-22",5,3.52,74.54,,0,0.001,57.243,0.0596,0.009,0.0474,961.62,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-23",5,3.29,69.03,,0,0.001,53.561,0.0596,0.009,0.0678,899.947,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-25",8,6.65,204.23,,0.001,0.001,138.527,0.059,0.013,0.0253,2330.12,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-26",8,6.87,289.65,,0.001,0.001,175.651,0.059,0.015,0.0104,2955.933,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-27",9,7.78,317.44,,0.001,0.001,193.638,0.0593,0.014,0.0223,3257.378,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-02",3,1.27,24.43,,0,0.001,20.481,0.059,0.007,0.1037,345.315,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-03",4,2.6,86.12,,0,0.001,56.072,0.0593,0.009,0.052,944.532,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-04",2,1.7,34.85,,0,0.001,27.455,0.059,0.008,0.034,462.57,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-09",5,3.55,90.17,,0,0.001,61.445,0.0594,0.009,0.0458,1033.757,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-10",4,3.02,99.69,,0,0.001,62.569,0.0593,0.01,0.0258,1053.286,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-11",5,3.58,84.4,,0,0.001,59.576,0.0592,0.009,0.0422,1002.322,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-22",5,3.39,74.07,,0,0.001,53.905,0.0594,0.008,0.056,907.205,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-23",5,3.45,74.41,,0,0.001,54.507,0.059,0.008,0.0526,918.261,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-25",5,4.23,143.54,,0,0.001,90.445,0.0592,0.011,0.0232,1522.421,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-09",3,2,53.62,,0,0.001,37.7,0.059,0.008,0.0427,635.248,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-10",3,1.37,27.73,,0,0.001,21.837,0.059,0.007,0.0973,367.763,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-11",5,4.09,129.06,,0,0.001,84.567,0.0592,0.012,0.0264,1422.713,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-12",5,3.64,102.15,,0,0.001,69.823,0.0592,0.01,0.0386,1175.714,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-13",3,1.25,25.3,,0,0.001,19.709,0.0593,0.007,0.1113,331.321,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-20",3,1.3,25.6,,0,0.001,20.552,0.059,0.007,0.0937,345.902,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-21",3,1.37,26.79,,0,0.001,21.48,0.0593,0.007,0.1027,361.743,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-26",3,2.25,70.69,,0,0.001,46.702,0.0597,0.008,0.0277,785.006,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-27",5,3.44,73.36,,0,0.001,56.776,0.0592,0.008,0.0506,956.384,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-28",5,3.4,73.52,,0,0.001,56.128,0.0592,0.008,0.0556,944.588,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-29",6,4.42,97.18,,0,0.001,73.686,0.0593,0.009,0.0442,1239.596,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-30",7,6.55,193.31,,0.001,0.001,129.538,0.059,0.018,0.0199,2181.612,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-07-31",5,3.25,69.3,,0,0.001,53.485,0.0594,0.008,0.0644,899.341,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-01",4,2.25,47.79,,0,0.001,36.668,0.059,0.008,0.093,618.076,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-02",5,3.25,70.52,,0,0.001,53.797,0.059,0.009,0.082,905.245,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-03",4,2.3,49.18,,0,0.001,37.786,0.0598,0.008,0.0775,635.776,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-04",1,0.32,3.52,,0,0.001,3.808,0.06,0.006,0.175,63.84,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-06",6,5.12,232.96,,0.001,0.001,134.534,0.0593,0.015,0.0202,2262.486,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-09",2,1.33,26.77,,0,0.001,20.342,0.0595,0.007,0.0395,342.196,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-10",3,1.73,36.12,,0,0.001,26.949,0.0593,0.007,0.066,453.488,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-12",4,2.59,73.64,,0,0.001,48.832,0.0593,0.009,0.058,822.062,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-13",9,7.72,274.13,,0.001,0.001,166.555,0.0594,0.014,0.0188,2800.111,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-14",11,10.42,316.54,,0.001,0.001,198.97,0.0593,0.018,0.0118,3348.608,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-15",11,10.2,388.2,,0.001,0.001,229.06,0.0591,0.019,0.0117,3854.16,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-16",8,6.44,278.09,,0.001,0.001,159.071,0.0591,0.019,0.0289,2677.496,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-17",14,12.9,354.5,,0.001,0.001,232.82,0.0593,0.019,0.0188,3917.2,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-18",14,13.07,324.38,,0.001,0.001,218.578,0.0592,0.017,0.0158,3677.773,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-19",9,7.36,166.32,,0.001,0.001,115.068,0.0592,0.011,0.0409,1937.72,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-20",11,8.62,191.54,,0.001,0.001,133.836,0.0592,0.016,0.0422,2255.124,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-21",7,3.56,75.08,,0,0.001,55.234,0.0593,0.013,0.0847,929.749,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-22",6,2.54,51.66,,0,0.001,38.265,0.0593,0.012,0.0998,643.514,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-24",7,4.78,110.35,,0,0.001,78.717,0.0593,0.014,0.0467,1323.772,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-25",6,3.58,77.28,,0,0.001,55.906,0.059,0.012,0.0725,942.382,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-26",22,19.38,436.18,,0.002,0.001,306.25,0.0595,0.023,0.0259,5150.686,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-27",20,17.55,393.75,,0.001,0.001,276.605,0.0592,0.023,0.0262,4657.515,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-28",13,12.12,277.8,,0.001,0.001,195.312,0.0592,0.014,0.0193,3286.388,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-29",14,11.67,260.42,,0.001,0.001,183.544,0.059,0.019,0.0336,3093.764,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-30",12,9.34,209.24,,0.001,0.001,147.678,0.0595,0.014,0.0447,2482.016,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-08-31",13,11.27,256.03,,0.001,0.001,178.359,0.0592,0.015,0.0292,3002.375,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-01",13,11.27,256.03,,0.001,0.001,178.255,0.0594,0.015,0.0284,2998.834,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-02",12,10.27,233.15,,0.001,0.001,162.83,0.0593,0.015,0.0298,2738.63,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-03",12,10.4,233.92,,0.001,0.001,164.504,0.059,0.013,0.026,2770.696,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-04",13,12.33,278.27,,0.001,0.001,194.288,0.0593,0.015,0.0141,3269.369,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-05",10,7.88,176.64,,0.001,0.001,121.378,0.0592,0.012,0.0377,2042.616,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-06",9,6.38,203.94,,0.001,0.001,123.328,0.0593,0.014,0.0408,2073.65,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-07",7,5.18,113.78,,0,0.001,76.722,0.0594,0.007,0.0501,1289.638,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-08",5,3.24,68.16,,0,0.001,48.748,0.0596,0.008,0.0742,819.22,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-09",14,10.66,228.34,,0.001,0.001,163.154,0.0594,0.015,0.0404,2746.278,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-10",3,1.29,25.91,,0,0.001,19.158,0.0597,0.006,0.095,321.814,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-15",3,1.37,47.72,,0,0.001,30.065,0.0593,0.006,0.0823,505.723,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-16",3,1.32,26.72,,0,0.001,20.224,0.0593,0.006,0.0933,339.79,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-17",4,2.87,74.12,,0,0.001,50.989,0.059,0.008,0.0585,858.001,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-19",5,3.8,88.52,,0,0.001,63.452,0.0592,0.009,0.0402,1068.116,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-20",2,1.32,26.24,,0,0.001,20.417,0.0595,0.006,0.0385,342.971,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-21",2,1.3,26.06,,0,0.001,20.174,0.059,0.007,0.0385,339.436,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-28",5,4.05,88.28,,0,0.001,65.192,0.0592,0.011,0.0476,1096.024,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-29",5,3.3,72.36,,0,0.001,52.918,0.059,0.008,0.0676,890.918,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-09-30",7,5.5,123.2,,0,0.001,89.56,0.0594,0.01,0.0336,1506.64,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-01",5,3.9,93.3,,0,0.001,66.358,0.0596,0.008,0.0412,1115.664,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-02",6,4.31,95.68,,0,0.001,70.322,0.0597,0.009,0.0628,1181.893,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-03",4,2.33,57.01,,0,0.001,40.546,0.0593,0.007,0.0788,681.411,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-04",3,1.88,39.42,,0,0.001,30.014,0.06,0.007,0.0523,503.752,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-05",5,3.9,107.5,,0,0.001,73.16,0.0592,0.012,0.054,1230.41,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-06",3,1.85,44.65,,0,0.001,31.966,0.0593,0.01,0.0743,537.904,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-12",2,1.4,28,,0,0.001,21.84,0.059,0.007,0.047,368.249,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-13",3,1.76,42.04,,0,0.001,30.74,0.06,0.008,0.0883,516.068,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-14",4,3.35,122.18,,0,0.001,75.868,0.0598,0.012,0.0305,1275.015,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-15",3,2.53,59.51,,0,0.001,43.338,0.059,0.01,0.0283,728.871,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-16",3,1.42,29.34,,0,0.001,22.159,0.059,0.01,0.1147,372.909,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-18",3,2.2,46.35,,0,0.001,35.354,0.0593,0.009,0.034,594.422,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-19",3,2.34,59.36,,0,0.001,42.324,0.06,0.009,0.0263,710.553,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-20",5,2.81,75.74,,0,0.001,52.605,0.0596,0.012,0.0676,884.486,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-21",3,2.35,55.95,,0,0.001,41.018,0.059,0.008,0.0253,690.977,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-27",2,1.37,36.2,,0,0.001,25.584,0.059,0.013,0.06,430.609,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-01",1,0.12,0,,0,0.001,1.02,0.059,0.003,0.296,17.232,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-08",1,0.5,8,,0,0.001,6.65,0.06,0.005,0.084,111.75,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-09",3,1.85,36.04,,0,0.001,27.577,0.0593,0.008,0.0487,464.243,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-10",4,2.35,46.6,,0,0.001,35.265,0.0595,0.008,0.0935,594.565,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-11",3,2.43,48.4,,0,0.001,36.57,0.0593,0.008,0.0267,615.241,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-15",3,2.55,99.56,,0,0.001,60.486,0.059,0.011,0.022,1017.806,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-16",4,2.65,57.08,,0,0.001,42.022,0.0598,0.007,0.0525,706.939,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-20",6,4.56,208.36,,0.001,0.001,122.196,0.0593,0.016,0.0338,2055.42,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-22",2,1.55,30.13,,0,0.001,23.367,0.0595,0.007,0.039,392.755,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-11-30",2,1.3,33.8,,0,0.001,23.356,0.059,0.008,0.0415,393.44,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-01",2,1.55,45.41,,0,0.001,30.33,0.0595,0.009,0.0395,509.655,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-02",4,3.58,120.65,,0,0.001,76.857,0.0593,0.013,0.023,1293.056,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-03",4,3.42,108.38,,0,0.001,70.452,0.0593,0.012,0.023,1186.16,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-04",7,6.03,222.7,,0.001,0.001,137.593,0.0594,0.021,0.0229,2314.219,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-05",3,2.65,54.91,,0,0.001,41.296,0.0597,0.008,0.0253,694.478,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-06",2,1.25,23.75,,0,0.001,18.376,0.059,0.007,0.044,309.206,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-07",5,4.17,98.72,,0,0.001,71.146,0.0594,0.01,0.0224,1196.042,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-09",3,2.35,65.58,,0,0.001,44.329,0.059,0.009,0.0283,747.135,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-10",3,2.01,42.58,,0,0.001,31.677,0.0593,0.014,0.149,533.894,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-11",5,4.17,168.1,,0.001,0.001,101.563,0.0594,0.013,0.0198,1708.461,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-12",7,6.17,264.89,,0.001,0.001,158.16,0.0591,0.017,0.0173,2663.058,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-13",5,2.86,81.42,,0,0.001,54.262,0.0592,0.014,0.0576,913.054,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-14",5,4.64,105.92,,0,0.001,76.173,0.059,0.01,0.0178,1283.916,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-15",7,5.85,172.52,,0.001,0.001,114.583,0.059,0.012,0.0213,1929.908,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-16",10,8.7,307.13,,0.001,0.001,192.246,0.0591,0.025,0.0193,3235.235,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-27",3,2.57,55.12,,0,0.001,40.524,0.059,0.008,0.027,683.367,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-28",2,1.32,35.64,,0,0.001,24.3,0.0595,0.007,0.0355,409.14,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lambie Energy Center",55626,"UNIT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-16",3,1.35,26.86,,0,0.001,20.3,0.0593,0.007,0.125,342.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-02",3,1.36,27.4,,0,0.001,20.956,0.0593,0.006,0.1147,352.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-26",3,1.75,42.46,,0,0.001,30.389,0.059,0.009,0.0483,512.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-04",3,1.51,31.46,,0,0.001,23.446,0.059,0.016,0.132,395.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-14",5,4.32,158.65,,0,0.001,98.813,0.0592,0.011,0.02,1661.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-17",2,1.34,25.56,,0,0.001,20.088,0.0595,0.007,0.039,337.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-09",4,2.84,82.96,,0,0.001,55.949,0.059,0.009,0.0288,941.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-11",1,0.1,0,,0,0.001,0.65,0.059,0.002,0.318,11.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-18",10,6.76,144.53,,0.001,0.001,107.071,0.0593,0.014,0.0613,1802.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-19",4,2.32,47.88,,0,0.001,36.376,0.0595,0.007,0.078,611.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-20",7,6.67,303.66,,0.001,0.001,181.546,0.059,0.018,0.0149,3054.803,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-21",5,3.52,74.47,,0,0.001,55.747,0.059,0.009,0.045,937.603,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-22",5,3.5,74,,0,0.001,55.55,0.0592,0.009,0.0448,935.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-23",5,3.27,69.15,,0,0.001,51.862,0.0596,0.008,0.0666,871.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-24",6,4.4,93.64,,0,0.001,69.768,0.0595,0.009,0.0465,1172.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-25",8,6.62,147.97,,0.001,0.001,108.609,0.0595,0.012,0.0248,1825.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-26",7,6.63,242.07,,0.001,0.001,153.314,0.0591,0.015,0.013,2580.018,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-27",9,8.37,317.2,,0.001,0.001,198.675,0.0592,0.017,0.0122,3342.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-28",3,1.41,28.6,,0,0.001,21.769,0.059,0.006,0.103,367.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-30",6,4.29,91.25,,0,0.001,68.226,0.0593,0.009,0.0557,1148.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-02",4,2.29,47.66,,0,0.001,35.897,0.0593,0.007,0.0728,604.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-03",5,3.59,91.35,,0,0.001,63.633,0.0592,0.008,0.0442,1071.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-04",6,5.2,111.35,,0,0.001,82.546,0.0593,0.01,0.0178,1387.109,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-09",8,5.52,127.43,,0,0.001,92.393,0.0594,0.028,0.074,1554.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-10",4,3,99.6,,0,0.001,64.548,0.0593,0.011,0.0305,1085.441,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-11",5,2.82,61.72,,0,0.001,45.471,0.0592,0.012,0.0698,765.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-22",5,3.37,71.1,,0,0.001,52.931,0.0592,0.008,0.0542,889.823,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-24",8,7.12,251.9,,0.001,0.001,158.549,0.0591,0.012,0.0124,2670.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-09",3,1.99,56.66,,0,0.001,37.693,0.0593,0.004,0.0133,633.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-10",3,1.35,27.97,,0,0.001,20.532,0.0593,0.006,0.089,344.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-11",5,3.82,141.17,,0,0.001,88.415,0.0592,0.01,0.025,1488.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-12",5,3.64,98.78,,0,0.001,67.32,0.0592,0.008,0.0332,1132.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-13",5,2.53,49.66,,0,0.001,37.922,0.0594,0.01,0.0896,637.122,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-20",3,1.29,25.2,,0,0.001,19.248,0.0593,0.006,0.1007,324.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-26",3,2.24,69.86,,0,0.001,45.792,0.0593,0.008,0.0277,769.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-27",5,3.42,72.18,,0,0.001,53.294,0.0594,0.008,0.0538,896.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-28",5,3.39,71.46,,0,0.001,52.557,0.0592,0.007,0.053,886.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-29",6,4.42,94.18,,0,0.001,69.352,0.0598,0.008,0.0457,1164.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-30",6,4.95,155.05,,0.001,0.001,99.703,0.0593,0.009,0.0225,1678.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-07-31",5,3.24,68.4,,0,0.001,50.368,0.0592,0.008,0.0686,848.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-01",4,2.25,46.18,,0,0.001,34.513,0.0593,0.006,0.0853,579.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-02",6,4.27,90.73,,0,0.001,67.016,0.0593,0.009,0.0575,1127.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-03",4,2.29,47.25,,0,0.001,35.168,0.0595,0.007,0.081,591.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-06",3,1.72,36.21,,0,0.001,26.652,0.059,0.011,0.0753,448.559,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-09",2,1.3,24.84,,0,0.001,19.368,0.059,0.006,0.0375,326.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-10",3,1.7,34.24,,0,0.001,25.912,0.059,0.007,0.0713,436.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-12",4,2.37,63.98,,0,0.001,43.574,0.0593,0.007,0.0735,733.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-13",9,7.7,279.63,,0.001,0.001,174.622,0.0591,0.014,0.0192,2938.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-14",11,10.4,311.94,,0.001,0.001,205.492,0.0592,0.016,0.0104,3460.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-15",11,10.22,391.29,,0.001,0.001,240.709,0.0591,0.018,0.0105,4049.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-16",10,7.81,231.08,,0.001,0.001,153.143,0.0595,0.015,0.0339,2574.197,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-17",13,11.56,311.16,,0.001,0.001,212.244,0.0591,0.021,0.0175,3573.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-18",14,13.05,313.6,,0.001,0.001,221.385,0.0591,0.016,0.0155,3726.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-19",9,7.35,160.48,,0.001,0.001,117.129,0.0597,0.012,0.043,1968.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-20",11,8.62,182.92,,0.001,0.001,134.234,0.0593,0.016,0.0452,2259.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-21",4,2.3,47.37,,0,0.001,35.101,0.0593,0.006,0.0738,590.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-22",3,1.22,24,,0,0.001,18.256,0.0593,0.006,0.1073,307.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-24",7,5.87,135.03,,0,0.001,96.09,0.0593,0.01,0.0266,1618.357,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-25",6,3.52,73.31,,0,0.001,54.302,0.0593,0.01,0.0725,913.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-26",22,19.35,420.83,,0.002,0.001,305.441,0.0592,0.023,0.0296,5143.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-27",17,14.5,313,,0.001,0.001,228.29,0.0593,0.021,0.0349,3842.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-28",11,9.22,199.88,,0.001,0.001,145.704,0.0594,0.012,0.0359,2452.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-29",13,11.54,249.68,,0.001,0.001,181.714,0.0592,0.017,0.0253,3058.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-30",12,9.36,200.4,,0.001,0.001,146.452,0.0592,0.013,0.0453,2467.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-08-31",11,9.27,201,,0.001,0.001,146.86,0.0595,0.012,0.0324,2469.571,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-01",13,11.29,244.98,,0.001,0.001,179.177,0.0598,0.016,0.0292,3009.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-02",12,10.27,223,,0.001,0.001,162.348,0.0593,0.014,0.0302,2733.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-03",12,10.4,225.64,,0.001,0.001,165.028,0.0595,0.013,0.0257,2773.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-04",14,12.55,270.65,,0.001,0.001,198.145,0.0594,0.015,0.0241,3332.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-05",10,7.91,171.27,,0.001,0.001,124.981,0.0591,0.012,0.0405,2103.843,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-06",9,6.7,213.42,,0.001,0.001,137.514,0.0593,0.016,0.0452,2312.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-07",7,5.22,111.66,,0,0.001,81.478,0.0591,0.009,0.0593,1372.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-08",4,2.22,45.98,,0,0.001,34.02,0.059,0.007,0.0993,573.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-09",13,9.64,205.86,,0.001,0.001,150.688,0.0592,0.016,0.0492,2537.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-10",3,1.27,24.88,,0,0.001,19.103,0.06,0.005,0.1007,320.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-15",3,1.33,26.11,,0,0.001,19.794,0.0593,0.006,0.1033,333.661,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-16",3,1.3,25.6,,0,0.001,19.35,0.059,0.005,0.0973,325.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-17",4,2.87,71.35,,0,0.001,49.684,0.0593,0.007,0.0638,835.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-18",2,1.35,26.38,,0,0.001,20.232,0.059,0.008,0.045,340.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-19",5,3.79,86.58,,0,0.001,62.311,0.0594,0.008,0.0434,1047.903,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-20",2,1.3,25.45,,0,0.001,19.336,0.059,0.006,0.0375,325.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-21",2,1.42,26.98,,0,0.001,20.91,0.059,0.007,0.037,352.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-28",5,4.04,86.29,,0,0.001,63.009,0.0592,0.01,0.0422,1060.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-29",5,3.29,69.25,,0,0.001,50.968,0.0594,0.007,0.066,858.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-09-30",7,5.5,118.17,,0,0.001,86.385,0.0593,0.009,0.0309,1454.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-01",5,3.88,90.8,,0,0.001,65.12,0.0592,0.008,0.0542,1095.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-02",6,4.28,91.4,,0,0.001,67.292,0.0592,0.008,0.0625,1133.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-03",3,2.07,50.39,,0,0.001,35.67,0.06,0.007,0.0533,599.259,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-04",3,2.36,65.62,,0,0.001,44.36,0.059,0.008,0.026,747.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-05",5,3.88,115.74,,0,0.001,75.868,0.0592,0.01,0.0536,1277.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-06",2,1.34,34.1,,0,0.001,23.38,0.059,0.008,0.0385,394.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-07",4,2.57,53.52,,0,0.001,39.341,0.0595,0.007,0.0478,661.667,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-12",16,12.68,272.32,,0.001,0.001,198.61,0.0596,0.019,0.0408,3338.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-13",15,11.65,250.54,,0.001,0.001,182.602,0.0592,0.018,0.0467,3071.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-14",18,14.65,316.24,,0.001,0.001,230.413,0.0591,0.021,0.0425,3878.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-15",13,10.23,233.71,,0.001,0.001,167.334,0.0592,0.019,0.0409,2815.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-16",19,15.84,343.7,,0.001,0.001,249.958,0.0595,0.024,0.0366,4205.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-17",13,9.64,205.61,,0.001,0.001,150.125,0.0593,0.018,0.0548,2526.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-18",11,8.67,184.15,,0.001,0.001,135.14,0.0593,0.015,0.0433,2273.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-19",10,6.15,125.28,,0,0.001,93.306,0.0591,0.022,0.0695,1572.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-20",13,10.8,243.04,,0.001,0.001,175.747,0.0598,0.026,0.0351,2950.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-21",4,2.84,64.52,,0,0.001,46.732,0.0595,0.008,0.053,786.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-22",4,3.04,63.68,,0,0.001,47.06,0.0593,0.009,0.0625,792.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-25",1,0.07,0,,0,0.001,0.441,0.059,0.001,0.316,7.441,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-10-31",2,1.19,46.86,,0,0.001,28.733,0.059,0.01,0.0395,483.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-02",5,3.42,75.86,,0,0.001,55.112,0.0596,0.009,0.0646,927.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-04",5,4.5,111.22,,0,0.001,78.21,0.059,0.012,0.023,1315.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-05",6,4.85,103.52,,0,0.001,76.843,0.0593,0.01,0.026,1292.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-06",3,1.8,38.62,,0,0.001,28.287,0.0593,0.009,0.0323,476.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-09",4,2.9,60.86,,0,0.001,45.472,0.0593,0.009,0.0553,764.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-10",3,1.44,29.31,,0,0.001,21.976,0.0593,0.009,0.105,370.079,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-11",4,2.93,60.85,,0,0.001,45.459,0.059,0.008,0.0308,765.737,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-12",2,0.75,17.36,,0,0.001,12.514,0.059,0.012,0.196,210.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-15",3,2.43,104.14,,0,0.001,62.658,0.0593,0.011,0.02,1054.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-16",6,3.04,67.28,,0,0.001,49.256,0.0593,0.016,0.0913,828.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-17",3,1.66,33.88,,0,0.001,25.604,0.059,0.007,0.05,431.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-22",3,2.04,41.99,,0,0.001,31.51,0.0597,0.008,0.038,529.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-29",3,1.32,25.96,,0,0.001,19.944,0.059,0.007,0.103,336.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-11-30",4,3.07,86.03,,0,0.001,58.572,0.0593,0.011,0.0245,985.089,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-01",8,5.42,140.98,,0,0.001,97.949,0.059,0.021,0.0518,1649.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-02",5,4.12,143.17,,0,0.001,91.782,0.0594,0.012,0.0228,1543.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-03",4,3.4,114.84,,0,0.001,74.214,0.0593,0.013,0.0243,1248.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-04",8,6.52,266.81,,0.001,0.001,162.754,0.0593,0.024,0.0236,2738.547,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-05",3,2.65,54.91,,0,0.001,41.496,0.0593,0.008,0.0263,698.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-06",2,1.23,28.4,,0,0.001,20.719,0.059,0.009,0.061,349.289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-07",5,4.17,108.72,,0,0.001,76.149,0.059,0.012,0.0252,1282.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-09",2,1.84,37.67,,0,0.001,28.771,0.059,0.021,0.085,484.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-10",4,3.4,108.4,,0,0.001,71.22,0.0595,0.01,0.0218,1197.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-11",4,3.42,145.58,,0,0.001,88.864,0.059,0.014,0.0223,1495.698,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-12",7,6.15,281.49,,0.001,0.001,169.224,0.0593,0.018,0.0174,2847.679,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-13",5,3.34,105.92,,0,0.001,70.208,0.0592,0.017,0.0436,1182.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-14",5,4.37,97.39,,0,0.001,71.818,0.0592,0.01,0.0196,1208.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-15",6,5.34,172.97,,0.001,0.001,113.36,0.0595,0.013,0.0202,1906.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-16",10,8.46,311.26,,0.001,0.001,194.499,0.0591,0.026,0.0208,3274.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-27",5,3.56,75.65,,0,0.001,56.269,0.0592,0.008,0.0382,947.771,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-28",2,1.3,39.2,,0,0.001,26.31,0.059,0.01,0.044,442.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Goose Haven Energy Center",55627,"UNIT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-01",18,16.2,2707.06,,0.008,0.001,1509.059,0.059,0.106,0.0127,25393.225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-02",24,24,3531,,0.01,0.001,2000.7,0.059,0.098,0.0058,33666.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-03",24,24,4992,,0.013,0.001,2630.3,0.059,0.131,0.0059,44258.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-04",24,24,4775,,0.013,0.001,2539.5,0.059,0.126,0.0059,42735.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-05",20,18.25,3828.86,,0.01,0.001,2038.178,0.059,0.116,0.0111,34295.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-06",18,16.56,3093.43,,0.009,0.001,1684.275,0.059,0.101,0.0084,28338.383,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-07",19,18.11,3179.63,,0.009,0.001,1756.39,0.059,0.113,0.01,29555.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-08",8,6.72,885.58,,0.003,0.001,535.369,0.059,0.07,0.0385,9007.332,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-09",10,8,1084.47,,0.003,0.001,665.791,0.059,0.073,0.0273,11202.911,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-10",21,19.55,3796.54,,0.01,0.001,2041.206,0.059,0.109,0.0071,34347.616,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-11",20,18.32,3137.26,,0.009,0.001,1733.434,0.0591,0.096,0.0143,29168.474,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-12",19,17.8,3294.64,,0.009,0.001,1794.948,0.0591,0.107,0.0144,30203.716,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-13",24,24,4314,,0.012,0.001,2352.1,0.059,0.117,0.0059,39578.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-14",24,24,4573,,0.012,0.001,2457.4,0.059,0.117,0.0057,41349.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-15",24,24,4389,,0.012,0.001,2373.6,0.059,0.119,0.006,39941.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-16",24,24,4917,,0.013,0.001,2591.2,0.059,0.125,0.0057,43605.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-17",24,24,4666,,0.013,0.001,2498.9,0.059,0.123,0.0059,42048,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-18",24,24,4852,,0.013,0.001,2573.8,0.059,0.127,0.0058,43307.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-19",24,24,5034,,0.013,0.001,2655.6,0.059,0.13,0.0058,44681.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-20",24,24,5370,,0.014,0.001,2786.3,0.059,0.136,0.0058,46882.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-21",24,24,4727,,0.013,0.001,2513.6,0.059,0.123,0.0058,42296.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-22",24,24,4419,,0.012,0.001,2384.5,0.059,0.115,0.0058,40124.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-23",24,24,4517,,0.012,0.001,2434.6,0.059,0.12,0.0058,40966.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-24",24,24,4476,,0.012,0.001,2416.3,0.059,0.117,0.0058,40658.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-25",24,24,4830,,0.013,0.001,2566.1,0.059,0.127,0.0059,43179.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-26",19,17.3,3522.04,,0.01,0.001,1883.238,0.059,0.109,0.0149,31691.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-27",24,24,4396,,0.012,0.001,2387,0.059,0.117,0.0058,40161.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-28",24,24,4633,,0.012,0.001,2464.4,0.059,0.12,0.0058,41466,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-29",24,24,5261,,0.014,0.001,2744.2,0.059,0.134,0.0058,46176.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-30",24,24,4984,,0.013,0.001,2633.2,0.059,0.129,0.0058,44307.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-01-31",22,21.01,3765.25,,0.01,0.001,2058.389,0.059,0.109,0.0096,34634.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-01",19,17.85,3741.96,,0.01,0.001,1984.552,0.059,0.11,0.011,33394.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-02",20,19.34,3958.39,,0.011,0.001,2107.966,0.059,0.104,0.0069,35473.194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-03",21,19.23,4040.72,,0.011,0.001,2148.501,0.059,0.121,0.0088,36153.391,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-04",13,12.6,2457.64,,0.007,0.001,1345,0.059,0.103,0.015,22631.252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-05",24,24,4835,,0.013,0.001,2596.4,0.059,0.129,0.0059,43689.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-06",17,15.55,3014.29,,0.008,0.001,1623.598,0.059,0.109,0.0222,27318.008,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-07",21,19.47,3537.03,,0.01,0.001,1947.249,0.059,0.104,0.0094,32765.939,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-08",19,17.64,3587.4,,0.01,0.001,1919.128,0.059,0.117,0.0129,32292.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-09",21,19.64,3913.4,,0.011,0.001,2087.304,0.059,0.121,0.011,35122.296,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-10",24,24,4665,,0.013,0.001,2488.7,0.059,0.121,0.0058,41872.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-11",21,20.43,4134.77,,0.011,0.001,2197.287,0.059,0.12,0.0076,36973.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-12",22,21.5,4266.68,,0.011,0.001,2270.228,0.059,0.12,0.007,38202.438,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-13",21,20.23,4078.17,,0.011,0.001,2168.095,0.059,0.117,0.0083,36484.042,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-14",22,21.47,4441.23,,0.012,0.001,2354.502,0.059,0.124,0.0071,39618.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-15",21,19.25,3926.61,,0.011,0.001,2102.165,0.0591,0.14,0.0123,35373.742,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-16",18,16.46,3299.52,,0.009,0.001,1778.068,0.0591,0.134,0.0166,29919.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-17",24,24,4458,,0.012,0.001,2404,0.059,0.116,0.0057,40458.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-18",24,24,5142,,0.014,0.001,2696,0.059,0.133,0.0058,45363.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-19",24,24,5076,,0.013,0.001,2661.4,0.059,0.128,0.0057,44780.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-20",24,24,4922,,0.013,0.001,2604,0.059,0.126,0.0058,43817.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-21",24,24,5020,,0.013,0.001,2650.5,0.059,0.124,0.0056,44600.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-22",21,19.44,3424.77,,0.009,0.001,1878.725,0.059,0.101,0.011,31613.623,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-23",18,16.57,2877.61,,0.008,0.001,1592.263,0.059,0.1,0.0119,26793.056,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-24",20,18.28,3583.56,,0.01,0.001,1935.025,0.059,0.129,0.0128,32558.945,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-25",19,17.77,3643.98,,0.01,0.001,1952.13,0.059,0.136,0.0145,32847.969,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-26",24,24,4725,,0.013,0.001,2520.5,0.059,0.122,0.0058,42411.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-27",24,24,4869,,0.013,0.001,2585.2,0.059,0.122,0.0056,43495.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-28",24,24,4802,,0.013,0.001,2547.4,0.059,0.124,0.0058,42865.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-02-29",18,16.26,2999.42,,0.008,0.001,1631.07,0.0591,0.113,0.013,27445.922,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-01",19,17.82,3724.17,,0.01,0.001,1977.218,0.0591,0.113,0.0112,33269.415,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-02",21,19.28,3830.39,,0.01,0.001,2052.893,0.059,0.105,0.0104,34545.012,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-03",24,24,4766,,0.013,0.001,2542.3,0.059,0.123,0.0058,42775.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-04",24,24,4826,,0.013,0.001,2560.4,0.059,0.125,0.0058,43086,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-05",24,24,4971,,0.013,0.001,2621.5,0.059,0.122,0.0056,44111.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-06",24,24,4911,,0.013,0.001,2591.4,0.059,0.119,0.0055,43607.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-07",22,21.08,4420.08,,0.012,0.001,2347.96,0.059,0.126,0.0064,39509.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-08",20,18.29,3726.42,,0.01,0.001,1991.888,0.059,0.113,0.0137,33516.042,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-09",24,24,5354,,0.014,0.001,2792.7,0.059,0.134,0.0057,46994.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-10",24,24,5462,,0.014,0.001,2842,0.059,0.134,0.0056,47820.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-11",24,24,4923,,0.013,0.001,2610.4,0.059,0.126,0.0058,43927.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-12",24,24,5396,,0.014,0.001,2806.8,0.059,0.141,0.006,47230,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-13",24,24,5148,,0.014,0.001,2691.1,0.059,0.131,0.0058,45282.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-14",21,19.38,4063.06,,0.011,0.001,2149.03,0.059,0.117,0.0109,36161.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-15",21,19.4,3992.27,,0.011,0.001,2118.603,0.059,0.114,0.01,35650.557,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-16",24,24,5465,,0.014,0.001,2829,0.059,0.135,0.0057,47600.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-17",24,24,4704,,0.013,0.001,2501.5,0.059,0.125,0.0059,42096,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-18",24,24,4981,,0.013,0.001,2617.8,0.059,0.131,0.0059,44049,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-19",24,24,5219,,0.014,0.001,2720.5,0.059,0.134,0.0059,45780,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-20",24,24,4639,,0.012,0.001,2474.8,0.059,0.123,0.0059,41645.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-21",21,19.24,3861.2,,0.01,0.001,2059.769,0.059,0.112,0.0095,34658.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-22",21,19.92,4068.17,,0.011,0.001,2164.533,0.059,0.115,0.009,36420.041,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-23",24,23.18,4381.64,,0.012,0.001,2358.676,0.059,0.117,0.009,39693.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-17",2,1.1,13.4,,0,0.001,34.565,0.059,0.061,0.1515,582.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-18",5,3.96,199.84,,0.001,0.001,207.904,0.059,0.064,0.0432,3500.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-19",10,9.37,1556.07,,0.004,0.001,877.596,0.0591,0.086,0.0251,14766.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-20",11,9.41,1507.13,,0.004,0.001,853.152,0.0591,0.074,0.0268,14355.402,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-21",14,13.69,2059.23,,0.006,0.001,1188.931,0.059,0.099,0.0168,20007.258,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-22",16,15.2,2797.6,,0.008,0.001,1524.76,0.059,0.105,0.0111,25660.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-23",16,14.2,2458.7,,0.007,0.0009,1361.812,0.059,0.084,0.0107,22914.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-24",20,18.25,3677.9,,0.01,0.001,1969.145,0.0591,0.093,0.0117,33137.73,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-25",19,17.19,3521.47,,0.009,0.001,1869.478,0.059,0.098,0.0094,31453.932,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-26",17,15.45,2725.22,,0.008,0.001,1495.862,0.059,0.096,0.0169,25171.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-27",18,16.39,2778.23,,0.008,0.001,1538.313,0.059,0.091,0.0136,25880.974,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-28",21,19.33,3921.29,,0.011,0.001,2082.991,0.059,0.106,0.0108,35052.268,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-29",20,18.52,3642.46,,0.01,0.001,1943.421,0.0591,0.098,0.0073,32702.982,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-04-30",12,10.26,1449.5,,0.004,0.001,849.449,0.059,0.075,0.0225,14293.285,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-01",12,9.25,1511.35,,0.004,0.001,853.736,0.0591,0.089,0.025,14364.697,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-02",11,10.15,1652.75,,0.005,0.001,933.64,0.059,0.081,0.0176,15711.615,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-03",11,8.99,1404.76,,0.004,0.001,803.476,0.0591,0.07,0.0312,13519.804,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-04",12,11.45,1993.4,,0.006,0.001,1102.07,0.059,0.087,0.0209,18545.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-05",17,15.59,2990.07,,0.008,0.001,1609.442,0.059,0.1,0.0131,27084.779,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-06",13,11.54,2049.18,,0.006,0.001,1126.37,0.059,0.084,0.0132,18953.798,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-07",16,14.18,2610.94,,0.007,0.001,1420.4,0.059,0.079,0.0135,23900.877,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-08",22,20.3,4191.54,,0.011,0.001,2211.124,0.059,0.104,0.0103,37208.679,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-09",17,14.48,2949.28,,0.008,0.001,1569.072,0.0591,0.088,0.0163,26403.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-08",6,5.57,508.27,,0.002,0.001,356.472,0.059,0.153,0.093,5998.946,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-09",19,17.62,3486.5,,0.009,0.001,1865.14,0.059,0.11,0.0122,31384.762,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-10",20,18.64,3884.64,,0.01,0.001,2042.728,0.059,0.104,0.0097,34373.296,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-11",19,17.57,3666.12,,0.01,0.001,1918.724,0.059,0.1,0.0108,32287.086,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-12",18,16.66,3332.65,,0.009,0.001,1757.479,0.059,0.092,0.0095,29574.927,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-13",11,9.72,1712.08,,0.005,0.001,933.101,0.0591,0.08,0.0224,15699.732,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-14",12,10.88,1911.32,,0.005,0.001,1048.832,0.059,0.078,0.0187,17649.096,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-15",18,16.97,3371.26,,0.009,0.001,1780.572,0.0591,0.111,0.0102,29959.553,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-16",17,15.65,2910.78,,0.008,0.001,1575.749,0.059,0.107,0.0123,26513.796,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-17",16,15.82,2776.4,,0.008,0.001,1503.89,0.059,0.108,0.011,25307.038,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-18",17,16.15,2917.6,,0.008,0.001,1568.565,0.0591,0.113,0.0101,26394.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-19",18,16.87,3388.84,,0.009,0.001,1784.271,0.059,0.092,0.0098,30027.232,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-20",17,15.75,3031.72,,0.008,0.001,1611.156,0.059,0.086,0.0116,27111.746,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-21",16,14.66,2614.28,,0.007,0.001,1412.612,0.0591,0.094,0.017,23770.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-22",24,24,5167,,0.014,0.001,2681.3,0.059,0.119,0.0053,45119.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-23",24,24,5015,,0.013,0.001,2612.2,0.059,0.113,0.0052,43953.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-24",24,24,4967,,0.013,0.001,2591.4,0.059,0.114,0.0053,43602.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-25",24,24,5066,,0.013,0.001,2630.9,0.059,0.114,0.0052,44271,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-26",24,24,5078,,0.013,0.001,2641.6,0.059,0.113,0.0051,44449.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-27",20,18.48,3636.12,,0.01,0.001,1925.964,0.059,0.095,0.0103,32403.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-28",16,14.7,2793.44,,0.008,0.001,1500.046,0.059,0.087,0.014,25239.576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-29",19,17.17,3367.45,,0.009,0.001,1791.025,0.0591,0.097,0.0091,30136.253,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-06-30",19,17.77,3381.54,,0.009,0.001,1795.252,0.059,0.092,0.0087,30210.748,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-01",24,24,4812,,0.013,0.001,2515.4,0.059,0.113,0.0053,42329.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-02",24,24,4195,,0.011,0.001,2252.2,0.059,0.105,0.0056,37897.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-03",18,16.95,3516.62,,0.009,0.001,1848.303,0.059,0.104,0.0089,31100.064,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-04",15,14.83,2864.61,,0.008,0.001,1527.684,0.059,0.105,0.0123,25702.969,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-05",17,16.28,3341.98,,0.009,0.001,1758.804,0.059,0.105,0.0116,29596.932,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-06",24,23.28,4739.08,,0.013,0.001,2484.532,0.059,0.111,0.0056,41806.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-07",14,13.57,2668.83,,0.007,0.001,1410.679,0.059,0.086,0.0134,23735.194,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-08",17,15.72,2984.74,,0.008,0.001,1580.607,0.0591,0.094,0.0134,26594.239,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-09",19,17.4,3424.8,,0.009,0.001,1793.51,0.0591,0.093,0.0099,30177.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-10",24,24,4162,,0.011,0.001,2209.1,0.059,0.104,0.0056,37173,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-11",24,24,5193,,0.013,0.001,2658.2,0.059,0.113,0.005,44731.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-12",24,24,4909,,0.013,0.001,2534.8,0.059,0.11,0.0052,42656.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-13",24,24,5320,,0.014,0.001,2712.9,0.059,0.114,0.005,45645.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-14",24,24,5083,,0.013,0.001,2610.8,0.059,0.112,0.0052,43928.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-15",24,24,5305,,0.014,0.001,2692.2,0.059,0.123,0.0055,45300.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-16",24,24,4645,,0.012,0.001,2415.7,0.059,0.112,0.0056,40647.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-17",24,24,4868,,0.013,0.001,2511.1,0.059,0.113,0.0054,42253.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-18",24,24,5067,,0.013,0.001,2603,0.059,0.114,0.0053,43802.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-19",17,15.82,3176.34,,0.008,0.001,1658.2,0.059,0.092,0.0109,27902.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-20",24,24,4689,,0.012,0.001,2438.4,0.059,0.111,0.0055,41030.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-21",24,24,5209,,0.013,0.001,2662,0.059,0.113,0.0051,44792.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-22",24,24,4795,,0.013,0.001,2489.2,0.059,0.111,0.0054,41886.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-23",24,24,4645,,0.012,0.001,2420.3,0.059,0.114,0.0057,40724.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-24",24,24,4680,,0.012,0.001,2439.4,0.059,0.114,0.0057,41045.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-25",24,24,5139,,0.013,0.001,2640.4,0.059,0.116,0.0053,44428.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-26",23,21.4,4264.85,,0.011,0.001,2226.63,0.059,0.105,0.0103,37465.925,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-27",24,24,5313,,0.014,0.001,2711.2,0.059,0.116,0.0051,45623,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-28",24,24,5157,,0.013,0.001,2644.7,0.059,0.114,0.0052,44500.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-29",24,24,4920,,0.013,0.001,2533.2,0.059,0.114,0.0054,42623.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-30",24,24,4902,,0.013,0.001,2527.8,0.059,0.112,0.0053,42532.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-07-31",24,24,5085,,0.013,0.001,2606.7,0.059,0.113,0.0052,43865,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-01",24,24,5097,,0.013,0.001,2617,0.059,0.113,0.0052,44036.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-02",19,18.46,3739.79,,0.01,0.001,1950.329,0.059,0.107,0.0083,32818.905,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-03",24,24,4894,,0.013,0.001,2523.1,0.059,0.113,0.0054,42460.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-04",24,24,4757,,0.013,0.001,2477.7,0.059,0.113,0.0055,41691.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-05",24,24,4566,,0.012,0.001,2397.7,0.059,0.114,0.0058,40349.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-06",24,24,4279,,0.011,0.001,2266.3,0.059,0.111,0.006,38134.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-07",24,24,4634,,0.012,0.001,2417.9,0.059,0.113,0.0057,40685.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-08",19,17.31,3506.29,,0.009,0.001,1828.542,0.059,0.1,0.0136,30767.279,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-09",24,24,4882,,0.013,0.001,2529.6,0.059,0.115,0.0055,42566.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-10",24,24,5095,,0.013,0.001,2614.4,0.059,0.114,0.0053,43996.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-11",24,24,4591,,0.012,0.001,2393.3,0.059,0.114,0.0058,40269.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-12",24,24,4638,,0.012,0.001,2422.8,0.059,0.114,0.0057,40769,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-13",24,24,5054,,0.013,0.001,2597.1,0.059,0.114,0.0053,43699.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-14",24,24,4665,,0.012,0.001,2426.8,0.059,0.114,0.0057,40837.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-15",24,24,4399,,0.012,0.001,2312.7,0.059,0.112,0.0059,38916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-16",24,24,3806,,0.01,0.001,2053.6,0.059,0.111,0.0065,34557.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-17",24,24,4604,,0.012,0.001,2402.7,0.059,0.111,0.0056,40427.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-18",24,24,3658,,0.01,0.001,1995.7,0.059,0.102,0.0062,33580.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-19",24,24,4415,,0.012,0.001,2314.8,0.059,0.102,0.0053,38953.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-20",24,24,4139,,0.011,0.001,2197.6,0.059,0.109,0.0061,36975.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-21",24,24,4810,,0.013,0.001,2478.8,0.059,0.119,0.0058,41711,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-22",24,24,4339,,0.012,0.001,2284.4,0.059,0.113,0.006,38441.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-23",24,24,4479,,0.012,0.001,2347,0.059,0.109,0.0057,39492.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-24",24,24,5324,,0.014,0.001,2712.8,0.059,0.114,0.005,45649,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-25",24,24,4792,,0.013,0.001,2479.3,0.059,0.113,0.0055,41718.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-26",24,24,3977,,0.011,0.001,2133.7,0.059,0.109,0.0063,35903.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-27",24,24,4226,,0.011,0.001,2233.6,0.059,0.11,0.006,37584.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-28",24,24,4289,,0.011,0.001,2260.8,0.059,0.117,0.0063,38042,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-29",24,24,4577,,0.012,0.001,2371.7,0.059,0.116,0.0059,39910.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-30",19,18.53,3161.19,,0.009,0.001,1686.209,0.0591,0.095,0.0073,28375.565,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-08-31",24,24,4371,,0.012,0.001,2290.3,0.059,0.119,0.0063,38536.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-01",24,24,4775,,0.012,0.001,2462.9,0.059,0.114,0.0056,41440.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-02",24,24,4676,,0.012,0.001,2432,0.059,0.114,0.0057,40927.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-03",24,24,5138,,0.013,0.001,2613,0.059,0.113,0.0052,43967.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-04",24,24,4370,,0.012,0.001,2290.5,0.059,0.111,0.0059,38539.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-05",24,24,4251,,0.011,0.001,2239.6,0.059,0.11,0.006,37684,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-06",24,24,4250,,0.011,0.001,2241.9,0.059,0.109,0.0059,37719.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-07",24,24,3404,,0.009,0.001,1873.2,0.059,0.106,0.0068,31518.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-08",24,24,3911,,0.011,0.001,2092.1,0.059,0.11,0.0063,35205.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-09",24,24,4862,,0.013,0.001,2506.1,0.059,0.124,0.0059,42172.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-10",24,24,5262,,0.014,0.001,2678.8,0.059,0.135,0.006,45075.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-11",24,24,5449,,0.014,0.001,2758.7,0.059,0.124,0.0053,46423.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-12",24,24,5029,,0.013,0.001,2582.2,0.059,0.116,0.0054,43445.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-13",24,24,4962,,0.013,0.001,2558,0.059,0.115,0.0054,43043.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-14",24,24,5340,,0.014,0.001,2718.1,0.059,0.12,0.0053,45737.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-15",24,24,5306,,0.014,0.001,2709.9,0.059,0.119,0.0053,45600.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-16",24,24,4915,,0.013,0.001,2542.1,0.059,0.116,0.0055,42773.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-17",24,24,5254,,0.014,0.001,2692.2,0.059,0.116,0.0052,45301.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-18",24,24,5324,,0.014,0.001,2721.2,0.059,0.118,0.0052,45789.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-19",24,24,4764,,0.013,0.001,2484.9,0.059,0.115,0.0056,41812.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-20",24,24,4844,,0.013,0.001,2509.7,0.059,0.114,0.0055,42227.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-21",24,24,5182,,0.013,0.001,2652.7,0.059,0.116,0.0053,44632.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-22",24,24,5216,,0.013,0.001,2665.9,0.059,0.117,0.0053,44858.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-23",24,24,4838,,0.013,0.001,2500.2,0.059,0.118,0.0057,42069.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-24",24,24,4637,,0.012,0.001,2415.4,0.059,0.118,0.0059,40643.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-25",24,24,4517,,0.012,0.001,2364,0.059,0.114,0.0058,39777.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-26",19,18.33,3543.7,,0.009,0.001,1856.936,0.059,0.095,0.0076,31242.689,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-27",21,19.93,3605.37,,0.01,0.001,1919.239,0.059,0.1,0.0102,32294.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-28",24,24,4815,,0.013,0.001,2492.9,0.059,0.118,0.0057,41946,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-29",24,24,4623,,0.012,0.001,2414.6,0.059,0.117,0.0058,40630.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-09-30",17,15.85,2967.25,,0.008,0.001,1574.14,0.059,0.105,0.0135,26485.335,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-01",24,24,5042,,0.013,0.001,2590.9,0.059,0.114,0.0053,43599.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-02",24,24,5291,,0.014,0.001,2703.2,0.059,0.116,0.0051,45486.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-03",24,24,5139,,0.013,0.001,2632.4,0.059,0.114,0.0052,44296.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-04",24,24,4522,,0.012,0.001,2366.9,0.059,0.118,0.006,39832.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-05",24,24,5295,,0.014,0.001,2711.4,0.059,0.121,0.0053,45626.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-06",24,24,5461,,0.014,0.001,2783.2,0.059,0.117,0.005,46828,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-07",24,24,5480,,0.014,0.001,2785.7,0.059,0.117,0.005,46875.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-08",24,24,5142,,0.013,0.001,2638.6,0.059,0.114,0.0052,44402,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-09",24,24,5155,,0.013,0.001,2648.7,0.059,0.118,0.0053,44567.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-10",24,24,4951,,0.013,0.001,2566.1,0.059,0.117,0.0055,43181.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-11",20,18.79,3743.61,,0.01,0.001,1961.251,0.059,0.113,0.0123,33001.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-12",24,24,5174,,0.013,0.001,2659.6,0.059,0.12,0.0054,44751.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-13",24,24,4867,,0.013,0.001,2518.6,0.059,0.125,0.0059,42380,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-14",24,24,5088,,0.013,0.001,2651.1,0.059,0.128,0.0058,44612,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-15",24,24,5066,,0.014,0.001,2787.2,0.059,0.123,0.0053,46900.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-16",24,24,4784,,0.013,0.001,2661.8,0.059,0.118,0.0053,44788.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-17",24,24,4630,,0.013,0.001,2585.7,0.059,0.126,0.0058,43511.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-18",24,24,4851,,0.014,0.001,2690.4,0.059,0.124,0.0055,45271.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-19",24,24,5040,,0.014,0.001,2775.9,0.059,0.128,0.0055,46705.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-20",24,24,5008,,0.014,0.001,2759.9,0.059,0.118,0.0051,46442.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-21",24,24,4728,,0.013,0.001,2629,0.059,0.115,0.0053,44236.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-22",24,24,4912,,0.014,0.001,2714.7,0.059,0.125,0.0055,45682.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-23",2,1.08,170.32,,0,0.001,98.704,0.059,0.012,0.031,1661.508,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-26",2,1.1,21.86,,0,0.001,39.99,0.059,0.055,0.1765,673.055,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-27",11,10.48,1353.28,,0.004,0.001,846.556,0.059,0.088,0.0216,14245.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-28",14,12.13,2016.29,,0.006,0.001,1114.507,0.059,0.089,0.0114,18755.126,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-29",24,24,4984,,0.013,0.001,2571.4,0.059,0.141,0.0065,43272.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-30",24,24,4949,,0.013,0.001,2555,0.059,0.137,0.0064,42991.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-10-31",24,24,4821,,0.013,0.001,2503.3,0.059,0.133,0.0063,42118.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-01",24,24,4830,,0.013,0.001,2500.6,0.059,0.14,0.0067,42078,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-02",24,24,5334,,0.014,0.001,2711.1,0.059,0.148,0.0065,45619.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-03",24,24,5443,,0.014,0.001,2764.9,0.059,0.138,0.0059,46521.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-04",24,24,4843,,0.013,0.001,2514.9,0.059,0.133,0.0063,42319.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-05",24,24,3969,,0.012,0.001,2313,0.059,0.116,0.0061,38919.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-06",24,24,5042,,0.013,0.001,2592,0.059,0.126,0.0058,43613.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-07",24,24,4625,,0.012,0.001,2402.4,0.059,0.129,0.0063,40424.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-08",20,18.35,3339.1,,0.009,0.001,1781.165,0.059,0.109,0.0102,29972.978,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-09",24,24,5002,,0.013,0.001,2573.6,0.059,0.145,0.0067,43304.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-10",24,24,4898,,0.013,0.001,2539.3,0.059,0.142,0.0067,42725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-11",24,24,4840,,0.013,0.001,2505.6,0.059,0.137,0.0065,42161.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-12",24,24,4838,,0.013,0.001,2499.6,0.059,0.142,0.0068,42059.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-13",21,19.44,3876.59,,0.01,0.001,2017.749,0.059,0.128,0.0115,33953.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-14",18,16.57,2935.53,,0.008,0.001,1576.352,0.059,0.11,0.0173,26528.582,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-15",19,17.43,3389.2,,0.009,0.001,1780.785,0.059,0.118,0.016,29967.886,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-16",24,24,5057,,0.013,0.001,2593.3,0.059,0.138,0.0063,43638.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-17",24,24,5106,,0.013,0.001,2620.6,0.059,0.138,0.0063,44099.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-18",24,24,4650,,0.012,0.001,2425.7,0.059,0.133,0.0065,40819.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-19",24,24,4320,,0.012,0.001,2294.1,0.059,0.126,0.0066,38599.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-20",24,24,5017,,0.013,0.001,2579.6,0.059,0.132,0.0061,43406.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-21",24,24,4930,,0.013,0.001,2551.7,0.059,0.136,0.0063,42937.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-22",19,17.92,3562.07,,0.009,0.001,1877.839,0.0591,0.122,0.0109,31599.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-23",19,18.31,3678.94,,0.01,0.001,1916.129,0.059,0.118,0.0099,32243.709,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-24",24,24,4288,,0.012,0.001,2279.1,0.059,0.127,0.0067,38349.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-25",2,1.1,199.4,,0.001,0.001,104.76,0.059,0.009,0.061,1762.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-29",12,11.7,1767.4,,0.005,0.001,1044.05,0.0591,0.159,0.0408,17568.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-11-30",24,24,4834,,0.013,0.001,2507.1,0.059,0.131,0.0063,42185.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-01",21,20.07,3877.29,,0.01,0.001,2031.431,0.059,0.116,0.0087,34183.737,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-02",24,24,5041,,0.013,0.001,2582.3,0.059,0.136,0.0063,43452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-03",23,21.02,3928.24,,0.01,0.001,2073.003,0.059,0.127,0.0074,34877.217,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-04",24,24,4585,,0.012,0.001,2384.7,0.059,0.134,0.0067,40124.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-05",21,19.37,4005.32,,0.01,0.001,2070.303,0.059,0.128,0.0092,34838.809,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-06",22,20.5,3866.62,,0.01,0.001,2032.974,0.059,0.123,0.01,34207.366,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-07",24,24,4871,,0.013,0.001,2515.1,0.059,0.135,0.0064,42323.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-08",24,24,4501,,0.012,0.001,2371.2,0.059,0.127,0.0063,39899.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-09",24,24,4532,,0.012,0.001,2391.2,0.059,0.124,0.0062,40236.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-10",24,24,4976,,0.013,0.001,2575.8,0.059,0.131,0.0061,43346.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-11",24,24,4940,,0.013,0.001,2559.7,0.059,0.146,0.0068,43071.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-12",24,22.94,4792.33,,0.013,0.001,2495.441,0.059,0.144,0.0099,41988.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-13",24,24,4642,,0.012,0.001,2438.2,0.059,0.13,0.0063,41025.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-14",22,21.5,3901.82,,0.011,0.001,2091.542,0.059,0.124,0.0076,35196.65,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-15",24,24,4235,,0.011,0.001,2269,0.059,0.125,0.0066,38176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-16",24,24,4254,,0.012,0.001,2280.6,0.059,0.126,0.0066,38377.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-17",24,24,3837,,0.011,0.001,2104.2,0.059,0.114,0.0064,35408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-18",24,24,4534,,0.012,0.001,2402.5,0.059,0.135,0.0067,40423.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-19",20,18.73,3873.78,,0.01,0.001,2030.242,0.059,0.141,0.0105,34160.291,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-20",24,24,4571,,0.012,0.001,2414.2,0.059,0.136,0.0067,40622.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-21",24,24,5225,,0.014,0.001,2688.6,0.059,0.143,0.0063,45238.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-22",22,20.29,3783.69,,0.01,0.001,2016.408,0.059,0.115,0.008,33932.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-23",24,24,4881,,0.013,0.001,2541.3,0.059,0.133,0.0063,42765.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-24",24,24,5247,,0.014,0.001,2695.7,0.059,0.15,0.0066,45359.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-25",24,24,4715,,0.012,0.001,2462.9,0.059,0.134,0.0064,41441.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-26",24,24,4215,,0.011,0.001,2252.8,0.059,0.123,0.0065,37909.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-27",24,24,4576,,0.012,0.001,2403.8,0.059,0.124,0.0062,40446.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-28",24,24,4910,,0.013,0.001,2548.7,0.059,0.143,0.0067,42888.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-29",23,21.48,4398.08,,0.012,0.001,2312.292,0.059,0.145,0.0094,38907.856,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-30",22,20.85,3622.2,,0.01,0.001,1967.685,0.059,0.132,0.0125,33106.815,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT001",,"2020-12-31",24,24,5158,,0.013,0.001,2662.5,0.059,0.15,0.0067,44797.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-01",16,14.5,2456,,0.007,0.001,1337.07,0.059,0.107,0.0195,22501.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-02",24,24,3516,,0.01,0.001,1978,0.059,0.116,0.007,33284.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-03",22,21.08,4437.48,,0.012,0.001,2308.024,0.059,0.141,0.0107,38832.944,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-04",19,18.68,3878.86,,0.01,0.001,2025.363,0.059,0.13,0.0083,34084.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-05",18,16.7,3550.46,,0.009,0.001,1850.598,0.059,0.121,0.0122,31141.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-06",15,14.22,2638.47,,0.007,0.001,1412.574,0.059,0.1,0.0115,23767.938,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-07",9,8.14,1351.34,,0.004,0.001,745.658,0.059,0.073,0.0227,12547.552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-08",3,2.18,300.08,,0.001,0.001,170.23,0.0593,0.014,0.0277,2863.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-09",4,3.68,437.92,,0.001,0.001,269.652,0.059,0.07,0.0673,4537.776,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-10",18,16.75,3228.4,,0.009,0.001,1709.775,0.059,0.11,0.0094,28775.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-11",18,16.84,2954.2,,0.008,0.001,1595.844,0.059,0.101,0.0146,26850.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-12",17,16.05,3072.6,,0.008,0.001,1633.77,0.059,0.117,0.0158,27491.665,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-13",20,19.57,3607.09,,0.01,0.001,1936.643,0.059,0.121,0.0083,32587.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-14",19,17.63,3452.25,,0.009,0.001,1824.701,0.059,0.116,0.0115,30701.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-15",24,24,4361,,0.012,0.001,2338.6,0.059,0.137,0.007,39350,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-16",24,22.48,4509.08,,0.012,0.001,2366.946,0.059,0.141,0.0079,39829.082,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-17",19,18.6,3648.68,,0.01,0.001,1932.169,0.059,0.122,0.0083,32511.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-18",20,19.26,4034.02,,0.011,0.001,2106.772,0.059,0.131,0.0083,35451.829,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-19",19,18.1,3855.08,,0.01,0.001,2008.488,0.059,0.129,0.0098,33800.473,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-20",24,24,5329,,0.014,0.001,2742.9,0.059,0.16,0.0069,46153.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-21",24,24,4693,,0.012,0.001,2473.9,0.059,0.141,0.0068,41630.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-22",20,19.65,3715.57,,0.01,0.001,1973.034,0.059,0.121,0.0081,33200.276,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-23",19,17.46,3269.63,,0.009,0.001,1745.17,0.059,0.13,0.0164,29370.788,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-24",20,18.82,3613.66,,0.01,0.001,1917.296,0.059,0.117,0.0132,32262.706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-25",21,20.09,4122.79,,0.011,0.001,2161.283,0.059,0.139,0.0099,36369.501,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-26",17,15.8,3247.1,,0.009,0.001,1702.35,0.059,0.112,0.0164,28647.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-27",19,18.09,3402.94,,0.009,0.001,1819.699,0.059,0.115,0.0095,30620.544,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-28",24,24,4608,,0.012,0.001,2428.6,0.059,0.141,0.0069,40864.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-29",24,24,5222,,0.014,0.001,2699.6,0.059,0.159,0.007,45431.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-30",20,19.21,4121.82,,0.011,0.001,2143.716,0.059,0.135,0.0085,36070.193,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-01-31",19,17.78,3269.72,,0.009,0.001,1755.516,0.0591,0.113,0.0114,29537.766,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-01",18,16.75,3539.1,,0.009,0.001,1846.03,0.0591,0.118,0.0128,31061.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-02",17,16.26,3394.82,,0.009,0.001,1774.042,0.059,0.112,0.0091,29855.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-03",19,17.78,3811.84,,0.01,0.001,1989.374,0.0591,0.125,0.0099,33475.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-04",19,17.93,3766.66,,0.01,0.001,1975.011,0.059,0.127,0.0113,33236.186,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-05",21,20.3,4138.8,,0.011,0.001,2197.832,0.059,0.135,0.0084,36984.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-06",11,10.15,2064.1,,0.005,0.001,1081.03,0.0591,0.066,0.0156,18187.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-07",16,14.51,2697.2,,0.007,0.001,1456.062,0.059,0.124,0.0218,24502.907,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-08",17,16,3319.25,,0.009,0.001,1740.27,0.059,0.12,0.0124,29285.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-09",12,10.72,2159.74,,0.006,0.001,1136.883,0.0591,0.087,0.0143,19131.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-10",20,18.8,3567.9,,0.01,0.001,1897.3,0.059,0.119,0.0112,31927,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-11",19,18.07,3745.33,,0.01,0.001,1955.766,0.059,0.126,0.0097,32906.997,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-12",20,19.36,3910.74,,0.01,0.001,2053.404,0.0591,0.13,0.0092,34553.374,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-13",17,15.6,3260.8,,0.009,0.001,1702.7,0.059,0.118,0.0175,28648.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-14",20,19.21,4049.1,,0.011,0.001,2114.381,0.059,0.137,0.0095,35577.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-15",18,17.07,3516.09,,0.009,0.001,1848.547,0.059,0.14,0.0117,31105.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-16",15,14.37,2844.19,,0.008,0.001,1506.102,0.059,0.123,0.0181,25346.203,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-17",21,19.9,3617,,0.01,0.001,1943.405,0.059,0.119,0.0114,32703.159,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-18",22,20.93,4426.69,,0.012,0.001,2306.748,0.059,0.139,0.0097,38810.994,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-19",24,24,5019,,0.013,0.001,2611.2,0.059,0.15,0.0068,43938.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-20",19,18.69,3887.07,,0.01,0.001,2033.383,0.059,0.128,0.0083,34212.668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-21",20,19.52,4140.6,,0.011,0.001,2163.118,0.059,0.133,0.0084,36398.304,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-22",19,17.92,3229.31,,0.009,0.001,1733.48,0.059,0.106,0.0114,29171.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-23",16,14.48,2487.88,,0.007,0.001,1356.569,0.0591,0.105,0.0124,22829.178,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-24",17,16.65,3339.7,,0.009,0.001,1763.65,0.059,0.13,0.0118,29678.005,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-25",16,15.78,3217.02,,0.009,0.001,1693.098,0.059,0.123,0.0121,28491.506,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-26",20,19.25,3846.28,,0.01,0.001,2033.668,0.059,0.128,0.0087,34221.61,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-27",18,17.5,3705.92,,0.01,0.001,1938.114,0.059,0.125,0.009,32610.664,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-28",24,24,4747,,0.013,0.001,2503.8,0.059,0.145,0.0069,42133.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-02-29",16,14.62,2732.93,,0.007,0.001,1459.051,0.059,0.107,0.0155,24553.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-01",17,15.85,3338.75,,0.009,0.001,1743.5,0.059,0.117,0.0133,29337.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-02",18,17.04,3413.83,,0.009,0.001,1800.612,0.059,0.115,0.0122,30295.924,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-03",20,19.1,3890,,0.01,0.001,2046.6,0.059,0.128,0.0093,34439.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-04",24,24,4780,,0.013,0.001,2518,0.059,0.144,0.0068,42367.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-05",24,24,4922,,0.013,0.001,2578.1,0.059,0.147,0.0068,43381.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-06",24,24,4866,,0.013,0.001,2550.1,0.059,0.142,0.0066,42909.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-07",21,19.1,4034.12,,0.011,0.001,2108.802,0.059,0.13,0.0071,35480.664,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-08",18,16.29,3399.27,,0.009,0.001,1782.508,0.059,0.117,0.0147,29995.706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-09",24,24,5290,,0.014,0.001,2738.6,0.059,0.159,0.0069,46081.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-10",24,24,5383,,0.014,0.001,2780.4,0.059,0.161,0.0069,46787.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-11",24,24,4867,,0.013,0.001,2562.6,0.059,0.149,0.0069,43120.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-12",24,24,5319,,0.014,0.001,2746.7,0.059,0.161,0.007,46218.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-13",24,24,5094,,0.013,0.001,2643.6,0.059,0.155,0.007,44481.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-14",18,16.9,3545.34,,0.009,0.001,1848.486,0.059,0.117,0.0135,31105.596,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-15",18,16.99,3577.93,,0.009,0.001,1863.681,0.059,0.116,0.0113,31358.653,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-16",24,24,5396,,0.014,0.001,2772.2,0.059,0.163,0.007,46652.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-17",24,24,4657,,0.012,0.001,2456.8,0.059,0.143,0.0069,41341.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-18",24,24,4924,,0.013,0.001,2569.1,0.059,0.149,0.0069,43231.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-19",24,24,5156,,0.013,0.001,2668.2,0.059,0.155,0.0069,44899.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-20",24,24,4589,,0.012,0.001,2432.1,0.059,0.141,0.0069,40925.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-21",18,16.8,3416.84,,0.009,0.001,1790.566,0.059,0.112,0.0114,30129.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-22",19,17.81,3696.52,,0.01,0.001,1930.676,0.059,0.117,0.0104,32483.786,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-23",19,17.14,3361.17,,0.009,0.001,1777.809,0.059,0.115,0.0123,29914.319,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-19",4,2.88,36.12,,0,0.001,91.515,0.0595,0.059,0.0788,1539.067,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-21",5,4.72,749.8,,0.002,0.001,420.196,0.059,0.046,0.0254,7071.188,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-22",10,8.59,1361.48,,0.004,0.001,760.462,0.059,0.071,0.0221,12794.239,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-23",13,12.62,2100.16,,0.006,0.001,1152.872,0.059,0.089,0.0145,19401.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-24",16,14.15,2745.99,,0.007,0.001,1454.559,0.059,0.097,0.0134,24476.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-25",17,15.86,3291.94,,0.009,0.001,1722.302,0.0591,0.103,0.0118,28975.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-26",15,13.41,2427.77,,0.007,0.001,1305.501,0.0591,0.09,0.0169,21968.761,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-27",16,14.57,2404.02,,0.007,0.001,1320.201,0.059,0.098,0.0178,22215.295,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-28",18,16.8,3420.1,,0.009,0.001,1797.06,0.059,0.112,0.0138,30238.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-29",17,16.05,3165.1,,0.008,0.001,1668.87,0.059,0.1,0.0093,28079.985,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-04-30",9,7.48,1111.27,,0.003,0.001,626.289,0.059,0.064,0.0334,10537.296,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-01",9,6.73,1159.65,,0.003,0.001,630.207,0.0591,0.065,0.0289,10602.813,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-02",8,7.48,1282.68,,0.004,0.001,701.656,0.059,0.066,0.0285,11805.796,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-03",6,3.95,561.14,,0.002,0.001,319.82,0.059,0.047,0.0513,5382.825,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-04",10,9.22,1679.76,,0.005,0.001,902.57,0.059,0.082,0.0199,15183.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-05",15,13.46,2726.1,,0.007,0.001,1431.256,0.059,0.106,0.0191,24084.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-06",11,9.88,1820.89,,0.005,0.001,974.278,0.059,0.085,0.0232,16394.527,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-07",13,12.14,2344.32,,0.006,0.001,1240.049,0.059,0.082,0.0152,20868.169,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-08",15,14.88,3005.7,,0.008,0.001,1575.718,0.059,0.105,0.0102,26517.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-09",15,13.48,2770.12,,0.007,0.001,1437.931,0.0591,0.096,0.0141,24195.447,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-10",15,14.02,2666.44,,0.007,0.001,1427.635,0.059,0.096,0.0125,24020.507,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-11",10,9.07,1625.54,,0.004,0.001,887.298,0.059,0.076,0.0189,14930.246,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-12",16,14.57,2849.17,,0.008,0.001,1519.746,0.059,0.12,0.0155,25574.391,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-13",9,8,1517.4,,0.004,0.001,835.824,0.0591,0.075,0.0198,14064.328,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-14",15,14.53,2889.65,,0.008,0.001,1543.775,0.059,0.124,0.0165,25979.093,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-15",9,7.62,1408.24,,0.004,0.001,768.292,0.0591,0.059,0.0192,12927.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-16",9,7.83,1434.36,,0.004,0.001,783.953,0.059,0.068,0.0242,13192.314,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-17",16,14.08,2395.36,,0.007,0.001,1320.79,0.0591,0.09,0.0151,22227.377,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-18",9,8.73,1491.41,,0.004,0.001,830.428,0.059,0.071,0.0181,13969.577,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-19",7,5.72,875.78,,0.003,0.001,501.752,0.059,0.061,0.0343,8441.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-20",9,7.95,1246.3,,0.004,0.001,702.72,0.059,0.082,0.0299,11824.535,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-21",7,6.98,1252.7,,0.003,0.001,690.054,0.059,0.064,0.019,11613.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-22",7,5.85,926.48,,0.003,0.001,527.145,0.059,0.048,0.023,8870.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-24",9,8.17,1469.68,,0.004,0.001,809.132,0.059,0.086,0.0249,13616.651,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-25",17,15.68,2795.7,,0.008,0.001,1517.234,0.059,0.098,0.0142,25527.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-26",20,19.08,3928.49,,0.01,0.001,2069.968,0.059,0.122,0.0115,34829.324,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-27",16,14.82,2758.06,,0.008,0.001,1487.712,0.059,0.093,0.0114,25033.214,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-28",14,13.65,2538.8,,0.007,0.001,1371.525,0.059,0.097,0.0138,23077.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-29",17,15.55,3052.1,,0.008,0.001,1634.7,0.059,0.106,0.0201,27505.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-30",14,12.83,2436.39,,0.007,0.001,1324.441,0.059,0.109,0.0206,22289.827,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-05-31",10,9.05,1540.8,,0.004,0.001,856.047,0.059,0.073,0.0194,14405.535,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-01",20,19.05,3814.61,,0.01,0.001,2019.765,0.059,0.113,0.0082,33986.035,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-02",24,24,5385,,0.014,0.001,2790.5,0.059,0.143,0.0061,46955.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-03",24,24,4986,,0.013,0.001,2620.1,0.059,0.136,0.0062,44087.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-04",24,24,4848,,0.013,0.001,2559.6,0.059,0.135,0.0063,43070.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-05",16,14.03,2751.47,,0.007,0.001,1468.598,0.059,0.093,0.0198,24714.067,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-10",11,10.83,2087.6,,0.006,0.001,1109.781,0.059,0.101,0.0236,18673.293,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-11",17,16.1,3421.8,,0.009,0.001,1772.915,0.059,0.103,0.0102,29832.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-12",16,15.17,3057.68,,0.008,0.001,1598.761,0.059,0.106,0.0116,26903.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-13",4,3.07,548.35,,0.001,0.001,291.041,0.059,0.021,0.0263,4897.443,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-14",8,7.37,1319.81,,0.004,0.001,711.853,0.059,0.086,0.0361,11978.073,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-15",16,15.72,3185.96,,0.008,0.001,1661.596,0.059,0.119,0.0118,27960.252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-16",15,13.3,2507.32,,0.007,0.001,1340.872,0.059,0.095,0.0136,22563.102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-17",15,14.63,2615.6,,0.007,0.001,1398.798,0.059,0.105,0.0137,23538.871,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-18",16,14.98,2772.55,,0.007,0.001,1472.572,0.059,0.106,0.0094,24777.079,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-19",17,15.47,3171.77,,0.008,0.001,1647.816,0.059,0.11,0.0092,27728.197,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-20",15,13.89,2761.87,,0.007,0.001,1443.169,0.059,0.095,0.0131,24285.002,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-21",14,12.72,2385.27,,0.006,0.001,1262.813,0.0591,0.087,0.0161,21247.975,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-22",22,21.25,4442.5,,0.012,0.001,2315.35,0.059,0.127,0.0073,38964.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-23",24,24,4981,,0.013,0.001,2591.2,0.059,0.134,0.0062,43596.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-24",24,22.54,4485.38,,0.012,0.001,2358.458,0.059,0.124,0.0062,39687.772,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-25",24,24,5025,,0.013,0.001,2609.4,0.059,0.137,0.0063,43909.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-26",21,20.17,4198.31,,0.011,0.001,2188.783,0.059,0.122,0.0077,36834.411,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-27",18,17,3369.26,,0.009,0.001,1769.748,0.059,0.1,0.0104,29781.942,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-28",14,12.96,2589.22,,0.007,0.001,1364.216,0.059,0.09,0.0131,22953.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-29",17,15.9,3155.64,,0.008,0.001,1657.757,0.059,0.107,0.0122,27895.396,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-06-30",18,16.78,3198.35,,0.009,0.001,1683.993,0.059,0.1,0.0099,28334.353,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-01",20,18.74,3694.17,,0.01,0.001,1933.938,0.0591,0.122,0.011,32543.791,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-02",20,18.93,3342.67,,0.009,0.001,1789.612,0.059,0.109,0.0079,30109.813,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-03",16,15.67,3288.12,,0.009,0.001,1712.1,0.059,0.113,0.0113,28809.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-04",14,13.39,2669.58,,0.007,0.001,1403.945,0.059,0.101,0.0177,23621.322,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-05",16,15.26,3129.86,,0.008,0.001,1635.608,0.059,0.113,0.0133,27524.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-06",16,15.02,3127.59,,0.008,0.001,1615.437,0.059,0.104,0.0134,27184.502,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-07",18,16.93,3388.3,,0.009,0.001,1765.566,0.0591,0.102,0.0069,29707.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-08",14,13.08,2570.92,,0.007,0.001,1342.316,0.059,0.088,0.0121,22587.347,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-09",16,14.52,2937.44,,0.008,0.001,1524.336,0.0591,0.104,0.0124,25647.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-10",24,24,4124,,0.011,0.001,2189.9,0.059,0.124,0.0068,36848.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-11",24,24,5076,,0.013,0.001,2603.6,0.059,0.14,0.0064,43805.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-12",24,24,4835,,0.013,0.001,2498.9,0.059,0.133,0.0064,42053.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-13",24,24,5247,,0.014,0.001,2676.6,0.059,0.141,0.0063,45036.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-14",24,24,5220,,0.013,0.001,2657.3,0.059,0.145,0.0065,44715.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-15",24,24,4833,,0.013,0.001,2499.3,0.059,0.137,0.0065,42053.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-16",24,24,4589,,0.012,0.001,2387.8,0.059,0.13,0.0065,40182.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-17",24,24,4805,,0.013,0.001,2480.2,0.059,0.135,0.0065,41736.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-18",23,21.78,4566.1,,0.012,0.001,2344.04,0.059,0.13,0.0089,39442.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-19",16,14.81,2999.38,,0.008,0.001,1551.27,0.0591,0.097,0.0135,26104.227,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-20",24,24,4639,,0.012,0.001,2411.3,0.059,0.13,0.0065,40577.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-21",24,24,5153,,0.013,0.001,2634.3,0.059,0.136,0.0062,44325.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-22",22,21.2,4283.12,,0.011,0.001,2217.862,0.059,0.121,0.007,37320.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-23",21,20.27,3885.3,,0.01,0.001,2029.811,0.059,0.12,0.0082,34156.211,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-24",21,20.13,4006.05,,0.01,0.001,2078.29,0.059,0.118,0.0081,34965.503,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-25",21,20.1,4247.36,,0.011,0.001,2184.112,0.059,0.116,0.0076,36755.61,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-26",20,19.1,3798.66,,0.01,0.001,1971.805,0.059,0.11,0.0116,33178.048,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-27",24,24,5258,,0.014,0.001,2681.5,0.059,0.136,0.006,45121.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-28",24,24,5106,,0.013,0.001,2617,0.059,0.134,0.0061,44030.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-29",24,24,4877,,0.013,0.001,2510.2,0.059,0.133,0.0063,42237.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-30",24,24,4872,,0.013,0.001,2510.1,0.059,0.133,0.0063,42235.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-07-31",24,24,5060,,0.013,0.001,2592.4,0.059,0.137,0.0063,43621.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-01",23,22,4592.9,,0.012,0.001,2364.687,0.059,0.127,0.0073,39791.818,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-02",16,14.75,2967.91,,0.008,0.001,1539.056,0.0591,0.1,0.015,25897.213,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-03",24,24,4842,,0.013,0.001,2495.6,0.059,0.134,0.0064,41992.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-04",8,6.08,970.01,,0.003,0.001,533.712,0.0591,0.042,0.0286,8981.295,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-05",5,4.73,640.33,,0.002,0.001,365.403,0.059,0.041,0.023,6149.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-06",19,17.83,3327.18,,0.009,0.001,1743.691,0.059,0.103,0.0107,29334.145,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-07",21,19.82,3958.43,,0.01,0.001,2050.761,0.059,0.115,0.0101,34509.162,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-08",17,15.95,3291.9,,0.009,0.001,1696.115,0.0591,0.102,0.0156,28540.705,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-09",21,20.06,4180.8,,0.011,0.001,2156.214,0.059,0.118,0.0078,36284.876,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-10",24,24,5050,,0.013,0.001,2589.8,0.059,0.135,0.0062,43579.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-11",24,24,4548,,0.012,0.001,2372.3,0.059,0.128,0.0065,39919.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-12",17,15.54,3200.24,,0.008,0.001,1652.346,0.059,0.103,0.0119,27802.982,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-13",24,24,5020,,0.013,0.001,2576.4,0.059,0.137,0.0063,43352.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-14",24,24,4625,,0.012,0.001,2406.2,0.059,0.13,0.0065,40489.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-15",24,24,4355,,0.012,0.001,2292.8,0.059,0.126,0.0066,38577.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-16",24,24,3789,,0.01,0.001,2044.2,0.059,0.117,0.0068,34397,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-17",24,24,4579,,0.012,0.001,2387.6,0.059,0.127,0.0064,40173.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-18",24,24,3641,,0.01,0.001,1986.6,0.059,0.111,0.0067,33429.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-19",24,24,4388,,0.012,0.001,2300.7,0.059,0.119,0.0062,38716.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-20",24,24,4114,,0.011,0.001,2183.7,0.059,0.119,0.0066,36743.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-21",23,22.3,4280.7,,0.011,0.001,2223.004,0.059,0.123,0.0071,37405.036,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-22",24,24,4312,,0.011,0.001,2269.8,0.059,0.125,0.0066,38196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-23",24,24,4428,,0.012,0.001,2319.4,0.059,0.124,0.0064,39027.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-24",24,24,5232,,0.013,0.001,2664.6,0.059,0.134,0.006,44833,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-25",24,24,4723,,0.012,0.001,2446.2,0.059,0.131,0.0064,41165.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-26",24,24,3960,,0.011,0.001,2124.6,0.059,0.118,0.0067,35750.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-27",24,23.3,4029.2,,0.011,0.001,2138.48,0.059,0.12,0.0077,35988.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-28",24,23.38,4047.46,,0.011,0.001,2144.13,0.059,0.119,0.0065,36078.662,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-29",24,24,4543,,0.012,0.001,2353.4,0.059,0.131,0.0067,39599.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-30",18,17.22,2965.3,,0.008,0.001,1569.164,0.059,0.098,0.0089,26406.448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-08-31",21,20.75,3776.64,,0.01,0.001,1976.315,0.059,0.118,0.0075,33254.707,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-01",24,24,4714,,0.012,0.001,2433.7,0.059,0.135,0.0066,40950.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-02",22,20.86,4154.12,,0.011,0.001,2150.024,0.059,0.116,0.0078,36185.375,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-03",24,24,5117,,0.013,0.001,2597.9,0.059,0.136,0.0063,43715.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-04",24,24,4336,,0.011,0.001,2273.3,0.059,0.124,0.0065,38254.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-05",24,24,4228,,0.011,0.001,2225,0.059,0.122,0.0066,37436.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-06",24,24,4225,,0.011,0.001,2227,0.059,0.124,0.0067,37474.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-07",24,24,3389,,0.009,0.001,1866.1,0.059,0.11,0.007,31401.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-08",24,24,3884,,0.01,0.001,2078.5,0.059,0.122,0.007,34976.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-09",24,24,4832,,0.013,0.001,2486.3,0.059,0.141,0.0068,41838.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-10",24,24,5231,,0.013,0.001,2659.9,0.059,0.149,0.0067,44759.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-11",24,24,5385,,0.014,0.001,2726.1,0.059,0.154,0.0067,45872.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-12",23,22.79,4737.61,,0.012,0.001,2433.868,0.059,0.14,0.007,40957.529,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-13",21,19.97,4203.72,,0.011,0.001,2158.07,0.059,0.122,0.0105,36313.142,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-14",24,24,5272,,0.014,0.001,2683,0.059,0.143,0.0063,45148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-15",24,24,5302,,0.014,0.001,2701.7,0.059,0.138,0.0061,45460.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-16",24,24,4893,,0.013,0.001,2527.7,0.059,0.133,0.0063,42526.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-17",24,24,5208,,0.013,0.001,2666.7,0.059,0.137,0.0061,44868.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-18",24,24,5271,,0.014,0.001,2692.2,0.059,0.138,0.0061,45300.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-19",21,19.94,4088.16,,0.011,0.001,2114.27,0.059,0.116,0.0095,35573.884,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-20",22,21.63,4376.06,,0.011,0.001,2261.863,0.059,0.125,0.007,38059.739,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-21",24,24,5131,,0.013,0.001,2624.8,0.059,0.139,0.0063,44169.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-22",24,24,5163,,0.013,0.001,2636.6,0.059,0.148,0.0067,44362.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-23",24,24,4820,,0.013,0.001,2487,0.059,0.135,0.0065,41846.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-24",24,24,4630,,0.012,0.001,2406.9,0.059,0.13,0.0065,40497.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-25",21,20.25,3856.73,,0.01,0.001,2015.351,0.059,0.12,0.0083,33916.455,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-26",18,17,3319.78,,0.009,0.001,1722.688,0.059,0.104,0.0094,28987.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-27",19,17.76,3174.72,,0.008,0.001,1680.604,0.059,0.101,0.0128,28280.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-28",24,24,4785,,0.012,0.001,2474.5,0.059,0.134,0.0065,41638.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-29",23,20.97,3825.02,,0.01,0.001,2023.762,0.059,0.119,0.0085,34050.911,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-09-30",15,13.65,2660.58,,0.007,0.001,1383.429,0.059,0.088,0.0139,23279.646,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-01",24,24,5017,,0.013,0.001,2575.4,0.059,0.133,0.0062,43335.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-02",23,21.82,4637.94,,0.012,0.001,2381.488,0.059,0.125,0.0081,40074.964,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-03",24,24,5109,,0.013,0.001,2613.9,0.059,0.136,0.0062,43977.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-04",22,21.06,3911.68,,0.01,0.001,2051.046,0.059,0.122,0.0078,34509.562,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-05",24,22.98,4986.5,,0.013,0.001,2560.458,0.059,0.137,0.0067,43081.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-06",24,24,5443,,0.014,0.001,2769.6,0.059,0.145,0.0062,46601.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-07",24,24,5477,,0.014,0.001,2778.6,0.059,0.141,0.006,46754.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-08",24,24,5134,,0.013,0.001,2629.6,0.059,0.139,0.0063,44245.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-09",24,24,5144,,0.013,0.001,2636.7,0.059,0.141,0.0064,44368.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-10",22,21.25,4334.39,,0.011,0.001,2249.282,0.059,0.125,0.0074,37848.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-11",16,14.8,3005.54,,0.008,0.001,1564.076,0.059,0.097,0.0121,26318.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-12",24,24,5159,,0.013,0.001,2646.4,0.059,0.144,0.0065,44526.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-13",24,24,4866,,0.013,0.001,2513.5,0.059,0.136,0.0065,42295.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-14",24,22.94,4723.7,,0.012,0.001,2475.04,0.059,0.134,0.0073,41645.484,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-15",23,22.6,4617.56,,0.013,0.001,2552.844,0.059,0.135,0.0065,42957.424,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-16",23,21.78,4204.79,,0.012,0.001,2348.918,0.059,0.124,0.0077,39524.242,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-17",23,22.27,4183.78,,0.012,0.001,2348.956,0.059,0.133,0.0078,39526.967,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-18",23,21.75,4350.9,,0.012,0.001,2413.46,0.059,0.14,0.0088,40611.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-19",24,24,5027,,0.014,0.001,2763.3,0.059,0.147,0.0063,46492.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-20",24,24,4976,,0.014,0.001,2738.7,0.059,0.143,0.0062,46086.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-21",24,24,4697,,0.013,0.001,2608.6,0.059,0.138,0.0063,43898.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-22",24,24,4921,,0.014,0.001,2712.5,0.059,0.143,0.0063,45645.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-23",2,1.07,169.42,,0,0.001,97.948,0.0595,0.01,0.0385,1647.385,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-27",2,1.57,49.69,,0,0.001,58.449,0.059,0.068,0.156,983.575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-28",11,10.15,1700.67,,0.005,0.001,918.631,0.059,0.062,0.0099,15459.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-29",24,24,4957,,0.013,0.001,2555.6,0.059,0.137,0.0064,43000.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-30",24,24,4900,,0.013,0.001,2528.9,0.059,0.136,0.0064,42555.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-10-31",21,20.27,4001.74,,0.011,0.001,2086.238,0.059,0.122,0.008,35105.068,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-01",24,24,4798,,0.013,0.001,2480.8,0.059,0.136,0.0065,41745.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-02",24,24,5320,,0.014,0.001,2699.9,0.059,0.143,0.0063,45432.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-03",24,24,5417,,0.014,0.001,2748.8,0.059,0.143,0.0062,46253.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-04",18,15.47,2905.17,,0.008,0.001,1534.981,0.059,0.099,0.0106,25829.659,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-05",24,24,3930,,0.012,0.001,2292.3,0.059,0.125,0.0065,38572.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-06",24,24,5008,,0.013,0.001,2570.6,0.059,0.134,0.0062,43256.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-07",24,24,4604,,0.012,0.001,2385.8,0.059,0.13,0.0065,40146.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-08",17,15.9,2841.42,,0.008,0.001,1508.398,0.059,0.092,0.0111,25383.292,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-09",24,24,4970,,0.013,0.001,2552.9,0.059,0.139,0.0065,42954.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-10",18,17.05,3472.4,,0.009,0.001,1799.005,0.059,0.108,0.0098,30275.935,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-11",21,19.88,4085.58,,0.011,0.001,2102.37,0.059,0.123,0.0088,35378.702,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-12",24,24,4802,,0.013,0.001,2476.7,0.059,0.132,0.0064,41676.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-13",19,17.9,3656.23,,0.01,0.001,1882.099,0.059,0.111,0.0112,31668.943,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-14",16,15.02,2689.58,,0.007,0.001,1427.652,0.059,0.097,0.0126,24022.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-15",17,16,3180.7,,0.008,0.001,1649.99,0.059,0.102,0.0132,27764.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-16",24,24,5023,,0.013,0.001,2572.1,0.059,0.139,0.0065,43279.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-17",22,20.8,4436.48,,0.011,0.001,2269.988,0.059,0.128,0.0122,38196.668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-18",23,22.05,4202.57,,0.011,0.001,2196.639,0.059,0.124,0.008,36964.973,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-19",21,19.91,3549.49,,0.01,0.001,1885.059,0.059,0.109,0.01,31718.521,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-20",24,24,4977,,0.013,0.001,2557,0.059,0.137,0.0064,43023.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-21",19,18.14,3869.52,,0.01,0.001,1983.846,0.059,0.117,0.0087,33382.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-22",17,15.74,3113.94,,0.008,0.001,1621.219,0.059,0.102,0.0121,27281.581,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-23",11,9.36,1778.15,,0.005,0.001,932.176,0.0591,0.071,0.0234,15686.403,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-24",19,18.75,3447.45,,0.009,0.001,1817.869,0.059,0.113,0.0082,30590.914,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-25",2,1.07,185.14,,0,0.001,97.549,0.059,0.01,0.023,1640.807,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-29",4,2.5,55.01,,0,0.001,82.217,0.0598,0.071,0.0948,1382.822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-11-30",21,20.08,3908.88,,0.01,0.001,2039.098,0.059,0.12,0.0083,34310.365,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-01",20,18.84,3676.08,,0.01,0.001,1912.032,0.059,0.115,0.0092,32171.216,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-02",20,18.98,4005.39,,0.01,0.001,2047.596,0.059,0.12,0.0089,34455.273,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-03",20,19.48,3672.56,,0.01,0.001,1926.748,0.059,0.119,0.0085,32419.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-04",24,24,4563,,0.012,0.001,2369.6,0.059,0.128,0.0065,39870.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-05",19,17.85,3787.91,,0.01,0.001,1929.738,0.059,0.114,0.0099,32473.968,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-06",18,17.2,3385.12,,0.009,0.001,1751.832,0.059,0.112,0.0108,29476.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-07",24,24,4839,,0.013,0.001,2494.1,0.059,0.135,0.0065,41968.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-08",24,24,4473,,0.012,0.001,2353.7,0.059,0.128,0.0065,39607.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-09",19,18.5,3474.52,,0.009,0.001,1835.508,0.059,0.113,0.0089,30886.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-10",24,24,4936,,0.013,0.001,2552.9,0.059,0.137,0.0064,42953.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-11",24,24,4926,,0.013,0.001,2549.9,0.059,0.14,0.0065,42900.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-12",23,21.71,4547.07,,0.012,0.001,2354.61,0.059,0.132,0.009,39625.124,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-13",24,24,4605,,0.012,0.001,2420.8,0.059,0.131,0.0065,40733.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-14",19,18.57,3439.1,,0.009,0.001,1829.248,0.059,0.111,0.0087,30778.561,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-15",24,24,4224,,0.011,0.001,2263.4,0.059,0.124,0.0065,38081.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-16",24,24,4229,,0.011,0.001,2269.8,0.059,0.122,0.0064,38194.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-17",19,18.59,2840.2,,0.008,0.001,1574.831,0.059,0.099,0.0087,26499.579,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-18",24,22.98,4254.48,,0.011,0.001,2265.153,0.059,0.128,0.007,38117.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-19",18,17.15,3609.2,,0.009,0.001,1869.432,0.059,0.123,0.0119,31451.508,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-20",24,24,4534,,0.012,0.001,2397.2,0.059,0.127,0.0063,40337.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-21",20,18.91,4015.87,,0.01,0.001,2074.604,0.059,0.122,0.0107,34915.418,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-22",20,18.88,3531.22,,0.009,0.001,1872.124,0.059,0.109,0.0096,31501.291,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-23",24,24,4842,,0.013,0.001,2521.2,0.059,0.133,0.0063,42423.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-24",24,24,5195,,0.013,0.001,2670.6,0.059,0.143,0.0064,44934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-25",24,24,4698,,0.012,0.001,2449.3,0.059,0.134,0.0065,41214,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-26",24,24,4198,,0.011,0.001,2241.8,0.059,0.124,0.0066,37721.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-27",24,24,4548,,0.012,0.001,2386.8,0.059,0.127,0.0063,40160.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-28",24,24,4881,,0.013,0.001,2532.5,0.059,0.136,0.0064,42613,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-29",19,18.3,3905.1,,0.01,0.001,2019.46,0.059,0.122,0.0102,33978.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-30",19,18.43,3279.6,,0.009,0.001,1759.34,0.059,0.114,0.0108,29601.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT002",,"2020-12-31",4,2.74,367.53,,0.001,0.001,210.438,0.059,0.041,0.0513,3540.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-01",18,17.28,3431.96,,0.008,0.001,1571.875,0.059,0.11,0.0119,26449.844,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-02",24,24,4109,,0.01,0.001,1924.9,0.059,0.097,0.006,32384.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-03",24,24,5809,,0.013,0.001,2570.6,0.059,0.13,0.006,43251.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-04",24,24,5565,,0.013,0.001,2476.3,0.059,0.125,0.006,41670.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-05",20,19.01,4648.72,,0.01,0.001,2074.349,0.059,0.119,0.0088,34906.105,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-06",18,17.49,3859.74,,0.009,0.001,1747.918,0.059,0.116,0.0116,29410.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-07",21,19.85,4210.55,,0.01,0.001,1920.575,0.059,0.11,0.0071,32319.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-08",10,8.4,1469.7,,0.004,0.001,723.395,0.059,0.087,0.0333,12172.845,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-09",17,15.04,3154.51,,0.007,0.001,1457.86,0.0591,0.099,0.0171,24531.167,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-10",22,20.55,4677.8,,0.011,0.001,2107.256,0.059,0.116,0.0073,35458.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-11",21,19.27,3823.93,,0.009,0.001,1760.894,0.059,0.108,0.0169,29629.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-12",20,18.76,4031.22,,0.009,0.001,1834.116,0.059,0.123,0.0119,30864.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-13",24,24,5026,,0.012,0.001,2281.7,0.059,0.115,0.006,38394.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-14",21,19.16,4006.15,,0.009,0.001,1845.028,0.059,0.108,0.0102,31048.522,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-15",20,18.9,4041.35,,0.009,0.001,1853.36,0.0591,0.091,0.0115,31187.975,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-16",24,24,5737,,0.013,0.001,2543.8,0.059,0.117,0.0055,42802.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-17",24,24,5426,,0.012,0.001,2436,0.059,0.117,0.0058,40990.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-18",24,24,5638,,0.013,0.001,2517.7,0.059,0.119,0.0056,42363.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-19",21,20.05,4996.53,,0.011,0.001,2220.605,0.059,0.123,0.0088,37363.707,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-20",24,24,6238,,0.014,0.001,2740.9,0.059,0.128,0.0055,46123.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-21",24,24,5498,,0.012,0.001,2457,0.059,0.117,0.0057,41346.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-22",24,24,5158,,0.012,0.001,2322.2,0.059,0.11,0.0057,39081.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-23",24,24,5296,,0.012,0.001,2379.6,0.059,0.114,0.0057,40042.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-24",24,24,5219,,0.012,0.001,2352.8,0.059,0.114,0.0058,39590.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-25",21,19.28,4683.52,,0.011,0.001,2095.384,0.059,0.124,0.0173,35257.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-26",20,18.53,4302.54,,0.01,0.001,1935.957,0.059,0.115,0.0108,32573.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-27",24,24,5275,,0.012,0.001,2376,0.059,0.111,0.0056,39983.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-28",24,24,5588,,0.013,0.001,2484.2,0.059,0.115,0.0055,41799.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-29",21,20,4981.48,,0.011,0.001,2223.451,0.059,0.121,0.0071,37410.446,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-30",24,24,5794,,0.013,0.001,2576.2,0.059,0.122,0.0057,43350.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-01-31",24,24,5103,,0.012,0.001,2315.7,0.059,0.111,0.0058,38968.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-01",20,19.05,4701.82,,0.011,0.001,2097.987,0.059,0.117,0.0094,35301.863,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-02",19,18.09,4356.67,,0.01,0.001,1951.868,0.059,0.12,0.0103,32843.43,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-03",22,20.5,4975.68,,0.011,0.001,2231.454,0.059,0.121,0.0075,37549.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-04",22,21.02,5037.68,,0.011,0.001,2259.392,0.059,0.126,0.0069,38021.61,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-05",21,20,4838,,0.011,0.001,2167.332,0.059,0.117,0.0088,36467.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-06",18,16.26,3821.12,,0.009,0.001,1720.652,0.059,0.118,0.0202,28952.322,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-07",21,19.81,4344.01,,0.01,0.001,1970.982,0.059,0.115,0.0119,33164.511,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-08",20,19.29,4604.45,,0.01,0.001,2059.652,0.059,0.121,0.0097,34658.799,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-09",19,17.65,4170.76,,0.009,0.001,1872.405,0.059,0.123,0.0118,31507.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-10",24,24,5446,,0.012,0.001,2436.4,0.059,0.115,0.0057,40995.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-11",24,24,5589,,0.013,0.001,2495,0.059,0.117,0.0056,41982,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-12",24,24,5561,,0.013,0.001,2485.4,0.059,0.115,0.0055,41821.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-13",24,24,5603,,0.013,0.001,2501.5,0.059,0.118,0.0056,42092.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-14",24,24,5751,,0.013,0.001,2562.9,0.059,0.12,0.0056,43124.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-15",22,20.22,4742.22,,0.011,0.001,2140.518,0.059,0.117,0.0104,36018.081,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-16",19,17.42,3997.62,,0.009,0.001,1806.08,0.0591,0.142,0.0176,30393.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-17",24,24,5195,,0.012,0.001,2344.4,0.059,0.112,0.0057,39446.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-18",24,24,6020,,0.013,0.001,2659.3,0.059,0.126,0.0056,44748.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-19",19,18.6,4550.12,,0.01,0.001,2034.047,0.059,0.123,0.0095,34229.698,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-20",21,20.08,4767.11,,0.011,0.001,2137.764,0.059,0.115,0.0086,35975.446,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-21",24,24,5822,,0.013,0.001,2588.3,0.059,0.124,0.0057,43552.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-22",21,19.9,4144.17,,0.01,0.001,1899.095,0.059,0.107,0.007,31953.002,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-23",19,17.3,3524.19,,0.008,0.001,1625.252,0.059,0.11,0.0209,27347.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-24",20,18.93,4342.13,,0.01,0.001,1964.037,0.059,0.128,0.0114,33047.522,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-25",20,18.45,4466.56,,0.01,0.001,2007.335,0.0591,0.142,0.0126,33779.727,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-26",21,19.95,4589.66,,0.01,0.001,2075.03,0.059,0.129,0.0094,34916.411,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-27",21,19.72,4780.59,,0.011,0.001,2144.971,0.059,0.136,0.0099,36092.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-28",24,24,5571,,0.013,0.001,2490.5,0.059,0.118,0.0057,41906,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-02-29",18,17.25,3793.98,,0.009,0.001,1721.621,0.059,0.124,0.0143,28969.644,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-01",1,0.77,157.08,,0,0.001,70.301,0.059,0.009,0.016,1183.028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-29",9,8.27,628.24,,0.003,0.001,507.024,0.059,0.089,0.0403,8533.077,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-30",9,7.1,1008.95,,0.003,0.001,533.942,0.059,0.076,0.0459,8983.323,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-03-31",20,18.1,3929.45,,0.009,0.001,1785.77,0.0591,0.1,0.0131,30051.115,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-01",17,15.72,3469.27,,0.008,0.001,1586.508,0.059,0.103,0.0215,26694.149,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-02",17,15.56,3642.8,,0.008,0.001,1646.968,0.0591,0.11,0.0239,27711.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-03",17,15.7,3481.6,,0.008,0.001,1593.33,0.059,0.117,0.0236,26812.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-04",17,15.69,3679.87,,0.008,0.001,1671.035,0.059,0.117,0.0242,28117.292,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-05",24,24,6244,,0.014,0.001,2757.4,0.059,0.133,0.0058,46397.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-06",24,24,6138,,0.014,0.001,2719.4,0.059,0.129,0.0056,45758,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-07",24,24,5720,,0.013,0.001,2559.6,0.059,0.121,0.0056,43069.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-08",24,24,6330,,0.014,0.001,2796.9,0.059,0.131,0.0056,47063.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-09",24,24,6339,,0.014,0.001,2799.8,0.059,0.132,0.0056,47109.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-10",24,24,5992,,0.013,0.001,2662.1,0.059,0.124,0.0055,44794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-11",17,15.73,3317.32,,0.008,0.001,1535.748,0.059,0.088,0.0161,25841.661,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-12",17,15.7,3659.2,,0.008,0.001,1665.8,0.059,0.115,0.0212,28030.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-13",18,16.42,3781.51,,0.009,0.001,1723.904,0.059,0.112,0.0232,29008.403,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-14",17,15.8,3616.89,,0.008,0.001,1656.838,0.0591,0.121,0.0189,27881.31,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-15",17,15.6,3586.89,,0.008,0.001,1634.676,0.059,0.116,0.0185,27507.753,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-16",18,16.23,3767.92,,0.009,0.001,1709.973,0.0591,0.117,0.0179,28771.423,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-17",20,18.8,4479.83,,0.01,0.001,2017.013,0.059,0.119,0.0133,33939.953,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-18",16,15.5,3686.98,,0.008,0.001,1663.76,0.059,0.099,0.0096,27995.726,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-19",8,7.1,1650.6,,0.004,0.001,740.39,0.059,0.038,0.0185,12460.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-20",11,10.03,1738.03,,0.004,0.001,881.927,0.059,0.113,0.025,14840.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-21",17,15.75,2906.5,,0.007,0.001,1382.085,0.059,0.109,0.0222,23257.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-22",19,17.23,3781.85,,0.009,0.001,1732.217,0.059,0.095,0.0145,29146.997,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-23",18,16.2,3330.4,,0.008,0.001,1550.77,0.059,0.107,0.0177,26095.595,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-24",21,19.24,4461.85,,0.01,0.001,2027.841,0.059,0.104,0.0135,34124.059,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-25",19,17.96,4255.6,,0.01,0.001,1925.756,0.059,0.104,0.0089,32406.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-26",17,15.57,3288.72,,0.008,0.001,1518.009,0.059,0.103,0.0189,25542.953,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-03",7,5.34,167.72,,0.001,0.001,220.796,0.059,0.119,0.0634,3714.786,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-04",8,7.32,1071.52,,0.003,0.001,605.532,0.059,0.086,0.0319,10189.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-05",17,15.95,3765.35,,0.008,0.001,1677.189,0.059,0.095,0.0091,28220.686,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-06",13,12.33,2513.98,,0.006,0.001,1160.744,0.059,0.084,0.0168,19531.951,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-07",15,14.7,3196.1,,0.007,0.001,1452.66,0.059,0.079,0.0079,24446.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-08",19,17.67,4322.71,,0.01,0.001,1915.09,0.059,0.122,0.0149,32227.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-09",18,17.3,4077.7,,0.009,0.001,1819.12,0.059,0.093,0.0077,30607.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-10",17,15.7,3513.35,,0.008,0.001,1580.415,0.059,0.118,0.0123,26597.825,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-11",13,11.33,2321.86,,0.005,0.001,1079.587,0.0591,0.094,0.033,18164.407,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-12",17,15.5,3643.65,,0.008,0.001,1634.265,0.059,0.103,0.0217,27500.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-13",11,9.75,2070.25,,0.005,0.001,962.7,0.059,0.084,0.0233,16199.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-14",17,15.69,3680.26,,0.008,0.001,1653.763,0.059,0.111,0.0145,27829.488,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-15",10,9.97,2161.55,,0.005,0.001,1003.801,0.059,0.09,0.0197,16891.285,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-16",13,12.11,2761.67,,0.006,0.001,1267.7,0.059,0.096,0.0155,21333.182,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-17",17,15.13,3165.21,,0.007,0.001,1449.079,0.059,0.088,0.0114,24383.123,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-18",8,6.8,1331.23,,0.003,0.001,634.537,0.059,0.077,0.038,10676.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-19",8,7.63,1487.9,,0.004,0.001,698.56,0.059,0.075,0.0243,11754.052,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-20",6,5.53,908.87,,0.002,0.001,457.114,0.059,0.084,0.0507,7691.828,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-21",9,8.37,1822.49,,0.004,0.001,847.926,0.0591,0.083,0.0238,14266.926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-22",9,7.72,1528.04,,0.004,0.001,719.947,0.059,0.08,0.046,12114.379,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-24",12,11.45,2298.85,,0.006,0.001,1099.655,0.059,0.131,0.0332,18503.305,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-25",17,16.82,3634.34,,0.008,0.001,1650.542,0.059,0.094,0.0075,27775.862,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-26",21,20.85,5112.51,,0.011,0.001,2276.36,0.059,0.116,0.0063,38305.568,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-27",17,16.15,3757.62,,0.009,0.001,1684.814,0.059,0.083,0.0091,28351.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-28",16,15.5,3515.36,,0.008,0.001,1594.264,0.059,0.108,0.0147,26828.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-29",17,16.6,4049.4,,0.009,0.001,1813.89,0.059,0.11,0.0098,30523.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-30",15,14.52,3152.84,,0.007,0.001,1445.632,0.059,0.086,0.0101,24325.234,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-05-31",17,15.6,3083.35,,0.007,0.001,1432.395,0.059,0.098,0.0206,24099.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-01",21,18.8,4359.35,,0.01,0.001,1974.56,0.059,0.108,0.0151,33225.955,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-02",24,24,6294,,0.014,0.001,2777.3,0.059,0.135,0.0058,46734.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-03",20,19.5,4812.7,,0.011,0.001,2152.89,0.059,0.113,0.0076,36226.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-04",21,19.98,4728.42,,0.011,0.001,2120.74,0.059,0.101,0.0073,35684.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-05",17,16.7,3964.05,,0.009,0.001,1776.21,0.059,0.115,0.0113,29887.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-06",11,9.72,1905.38,,0.005,0.001,899.274,0.059,0.093,0.0379,15131.717,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-07",13,11.7,2400.76,,0.006,0.001,1109.496,0.059,0.099,0.0334,18668.535,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-08",17,16.33,3880.7,,0.009,0.001,1731.115,0.059,0.093,0.0081,29129.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-09",20,19.05,4507.73,,0.01,0.001,2007.758,0.0591,0.119,0.0157,33785.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-10",22,20.27,4952.45,,0.011,0.001,2200.191,0.059,0.116,0.0103,37026.201,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-11",20,18.54,4499.14,,0.01,0.001,2003.892,0.0591,0.116,0.0125,33721.764,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-12",19,17.55,4119.93,,0.009,0.001,1842.858,0.059,0.109,0.0101,31010.231,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-13",12,10.86,2232.54,,0.005,0.001,1033.156,0.0591,0.08,0.0241,17382.442,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-14",14,12.7,2643.05,,0.006,0.001,1208.19,0.059,0.106,0.0273,20330.88,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-15",16,14.72,3289.7,,0.008,0.001,1485.94,0.059,0.096,0.0165,25004.43,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-16",13,11.91,2544.77,,0.006,0.001,1168.404,0.059,0.119,0.026,19661.188,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-17",16,14.67,3111.24,,0.007,0.001,1408.726,0.0591,0.098,0.0176,23700.902,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-18",18,17.05,3705.61,,0.008,0.001,1665.361,0.059,0.113,0.0127,28022.862,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-19",18,17.5,4142.4,,0.009,0.001,1846.63,0.059,0.102,0.0076,31073.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-20",16,15.01,3318.91,,0.008,0.001,1493.252,0.059,0.087,0.0093,25128.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-21",14,13.12,2742.06,,0.006,0.001,1253.446,0.0591,0.09,0.0155,21092.543,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-22",24,24,6014,,0.013,0.001,2647.8,0.059,0.128,0.0058,44554.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-23",24,24,5796,,0.013,0.001,2566.8,0.059,0.119,0.0055,43187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-24",24,24,5785,,0.013,0.001,2559.5,0.059,0.12,0.0056,43068.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-25",24,24,5860,,0.013,0.001,2590.6,0.059,0.119,0.0055,43588.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-26",24,24,5920,,0.013,0.001,2610.4,0.059,0.124,0.0057,43920.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-27",20,19.24,4419.37,,0.01,0.001,1981.25,0.059,0.097,0.0073,33340.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-28",17,15.42,3522.1,,0.008,0.001,1575.332,0.059,0.092,0.0091,26508.248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-29",8,6.58,1551.22,,0.003,0.001,686.742,0.0591,0.041,0.0166,11557.432,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-06-30",18,16.25,3098.05,,0.007,0.001,1481.615,0.059,0.135,0.0247,24930.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-01",24,24,5680,,0.013,0.001,2504.7,0.059,0.119,0.0057,42146.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-02",24,24,4939,,0.011,0.001,2220.5,0.059,0.109,0.0058,37362.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-03",19,18.05,4367.87,,0.01,0.001,1949.396,0.059,0.109,0.0106,32801.669,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-04",17,15.7,3520.1,,0.008,0.001,1592.611,0.059,0.104,0.0151,26798.553,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-05",17,15.75,3757.15,,0.008,0.001,1677.015,0.059,0.101,0.0184,28219.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-06",24,24,5750,,0.013,0.001,2543.9,0.059,0.112,0.0053,42805.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-07",24,24,5481,,0.012,0.001,2426.6,0.059,0.107,0.0053,40836.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-08",24,24,5263,,0.012,0.001,2333.9,0.059,0.104,0.0053,39273.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-09",24,24,5526,,0.012,0.001,2435,0.059,0.109,0.0053,40973.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-10",24,24,4831,,0.011,0.001,2166,0.059,0.099,0.0055,36446.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-11",24,24,5963,,0.013,0.001,2612.4,0.059,0.111,0.005,43957.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-12",24,24,5657,,0.013,0.001,2490.2,0.059,0.109,0.0053,41899.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-13",24,24,6108,,0.013,0.001,2666.2,0.059,0.113,0.005,44861.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-14",24,24,5835,,0.013,0.001,2558.1,0.059,0.11,0.0052,43045.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-15",24,24,5662,,0.013,0.001,2488.8,0.059,0.108,0.0052,41877.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-16",24,24,5812,,0.013,0.001,2541.6,0.059,0.12,0.0056,42769.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-17",24,24,5622,,0.012,0.001,2473.6,0.059,0.114,0.0055,41622.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-18",24,24,5883,,0.013,0.001,2573.6,0.059,0.114,0.0053,43311.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-19",17,15.73,3670.75,,0.008,0.001,1629.398,0.059,0.106,0.0159,27416.012,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-20",24,24,5433,,0.012,0.001,2399.6,0.059,0.111,0.0055,40378.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-21",24,24,5996,,0.013,0.001,2620.3,0.059,0.116,0.0053,44089,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-22",24,24,5570,,0.012,0.001,2456.5,0.059,0.114,0.0055,41335.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-23",24,24,5414,,0.012,0.001,2388.2,0.059,0.113,0.0057,40184.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-24",24,24,5435,,0.012,0.001,2400.2,0.059,0.112,0.0056,40384.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-25",24,24,5942,,0.013,0.001,2600.6,0.059,0.113,0.0052,43765.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-26",15,14.52,3326.48,,0.008,0.001,1489.464,0.059,0.106,0.0159,25063.304,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-27",24,24,6118,,0.013,0.001,2666.1,0.059,0.116,0.0052,44859.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-28",24,24,5943,,0.013,0.001,2597.6,0.059,0.113,0.0052,43711.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-29",24,24,5689,,0.013,0.001,2491.6,0.059,0.113,0.0054,41929.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-30",24,24,5663,,0.013,0.001,2482.8,0.059,0.112,0.0054,41774.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-07-31",24,24,5907,,0.013,0.001,2578.5,0.059,0.116,0.0054,43388.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-01",24,24,5872,,0.013,0.001,2562.9,0.059,0.115,0.0054,43125.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-02",21,19.92,4760.4,,0.011,0.001,2093.014,0.059,0.103,0.0107,35219.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-03",24,24,5664,,0.013,0.001,2481.4,0.059,0.115,0.0055,41749.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-04",24,24,5539,,0.012,0.001,2433.7,0.059,0.112,0.0055,40950,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-05",24,24,5376,,0.012,0.001,2362.6,0.059,0.114,0.0058,39752,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-06",24,24,4978,,0.011,0.001,2215.7,0.059,0.105,0.0057,37279.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-07",24,24,5375,,0.012,0.001,2366.9,0.059,0.108,0.0055,39827.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-08",19,17.76,4181.56,,0.009,0.001,1848.528,0.059,0.096,0.0147,31106.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-09",24,24,5663,,0.013,0.001,2485.7,0.059,0.109,0.0053,41828.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-10",24,24,5881,,0.013,0.001,2571.3,0.059,0.112,0.0052,43265.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-11",24,24,5312,,0.012,0.001,2345.9,0.059,0.107,0.0055,39471.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-12",24,24,5410,,0.012,0.001,2388.7,0.059,0.109,0.0055,40191.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-13",24,24,5830,,0.013,0.001,2556.8,0.059,0.114,0.0053,43028.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-14",24,24,5396,,0.012,0.001,2387.8,0.059,0.107,0.0054,40173.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-15",24,24,5077,,0.011,0.001,2266.8,0.059,0.105,0.0056,38146.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-16",24,24,4411,,0.01,0.001,2003.6,0.059,0.098,0.0058,33710.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-17",24,24,5312,,0.012,0.001,2354.5,0.059,0.105,0.0054,39619.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-18",24,24,4238,,0.01,0.001,1943,0.059,0.097,0.006,32691.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-19",24,24,5106,,0.011,0.001,2270.3,0.059,0.099,0.0052,38204.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-20",24,24,4765,,0.011,0.001,2141.8,0.059,0.098,0.0055,36043.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-21",24,24,5563,,0.012,0.001,2433.8,0.059,0.114,0.0056,40949.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-22",24,24,4938,,0.011,0.001,2203.3,0.059,0.107,0.0058,37075.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-23",24,24,5151,,0.012,0.001,2291.9,0.059,0.105,0.0055,38567.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-24",24,24,6097,,0.013,0.001,2661.1,0.059,0.113,0.005,44774.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-25",24,24,5494,,0.012,0.001,2420.1,0.059,0.108,0.0054,40719.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-26",24,24,4597,,0.011,0.001,2082.4,0.059,0.099,0.0057,35038.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-27",24,24,4882,,0.011,0.001,2186.6,0.059,0.103,0.0057,36797.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-28",24,24,5003,,0.011,0.001,2224.2,0.059,0.105,0.0057,37428.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-29",24,24,5300,,0.012,0.001,2333.5,0.059,0.113,0.0058,39265.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-30",20,18.61,3727.89,,0.008,0.001,1674.058,0.059,0.105,0.0135,28166.839,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-08-31",24,24,5111,,0.011,0.001,2253.1,0.059,0.114,0.006,37911.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-01",24,24,5516,,0.012,0.001,2414.1,0.059,0.121,0.006,40620.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-02",24,24,5432,,0.012,0.001,2385,0.059,0.12,0.006,40132.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-03",24,24,5984,,0.013,0.001,2588.1,0.059,0.131,0.006,43546.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-04",24,24,5054,,0.011,0.001,2238.2,0.059,0.113,0.006,37657.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-05",24,24,4949,,0.011,0.001,2196.8,0.059,0.111,0.006,36964.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-06",24,24,5021,,0.011,0.001,2225.9,0.059,0.112,0.006,37453.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-07",24,24,3970,,0.009,0.001,1817,0.059,0.092,0.006,30570.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-08",24,24,4544,,0.01,0.001,2039.7,0.059,0.102,0.006,34321.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-09",24,24,5646,,0.012,0.001,2465,0.059,0.124,0.006,41479.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-10",24,24,6106,,0.013,0.001,2645.1,0.059,0.135,0.0061,44507.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-11",24,24,6304,,0.014,0.001,2722.5,0.059,0.137,0.006,45811.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-12",24,24,5951,,0.013,0.001,2584.5,0.059,0.13,0.006,43486.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-13",24,24,5762,,0.013,0.001,2516.4,0.059,0.127,0.006,42343,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-14",24,24,6160,,0.013,0.001,2671.5,0.059,0.134,0.006,44951.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-15",24,24,6137,,0.013,0.001,2668.3,0.059,0.135,0.006,44902.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-16",24,24,5676,,0.013,0.001,2492.3,0.059,0.126,0.006,41940.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-17",24,24,6053,,0.013,0.001,2640.8,0.059,0.133,0.006,44431.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-18",24,24,6120,,0.013,0.001,2665.6,0.059,0.135,0.006,44854.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-19",24,24,5531,,0.012,0.001,2436.5,0.059,0.123,0.006,40997.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-20",24,24,5623,,0.012,0.001,2465,0.059,0.124,0.006,41475.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-21",24,24,5976,,0.013,0.001,2605.4,0.059,0.132,0.006,43840.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-22",24,24,6030,,0.013,0.001,2623.4,0.059,0.132,0.006,44142.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-23",24,24,5619,,0.012,0.001,2458.8,0.059,0.124,0.006,41372.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-24",24,24,5397,,0.012,0.001,2376.4,0.059,0.121,0.0061,39983.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-25",24,24,5257,,0.012,0.001,2318.5,0.059,0.117,0.006,39012.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-26",20,18.88,4276.96,,0.01,0.001,1889.912,0.059,0.104,0.0144,31802.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-27",21,20.03,4244.03,,0.01,0.001,1897.342,0.059,0.104,0.011,31927.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-28",24,24,5585,,0.012,0.001,2449.2,0.059,0.124,0.006,41215,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-29",23,22.55,5086.7,,0.011,0.001,2237.85,0.059,0.118,0.0068,37656.905,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-09-30",17,16.67,3835.41,,0.009,0.001,1697.154,0.059,0.114,0.0128,28560.099,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-01",24,24,5818,,0.013,0.001,2543,0.059,0.128,0.006,42789,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-02",21,20.05,4929.3,,0.011,0.001,2180.06,0.059,0.114,0.013,36684.025,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-03",7,6.55,720.5,,0.002,0.001,419.18,0.059,0.073,0.0436,7054.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-04",24,24,5321,,0.012,0.001,2339.7,0.059,0.119,0.0061,39367.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-05",24,24,6217,,0.014,0.001,2705.2,0.059,0.137,0.006,45523,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-06",24,24,6277,,0.014,0.001,2729.4,0.059,0.138,0.006,45928.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-07",24,24,6280,,0.014,0.001,2727.7,0.059,0.138,0.006,45901.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-08",24,24,5965,,0.013,0.001,2602.6,0.059,0.131,0.006,43796.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-09",24,24,5954,,0.013,0.001,2602.3,0.059,0.131,0.006,43785.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-10",24,24,5744,,0.013,0.001,2517.4,0.059,0.128,0.0061,42359.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-11",24,24,5485,,0.012,0.001,2427.3,0.059,0.123,0.006,40842.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-12",24,24,5979,,0.013,0.001,2623.2,0.059,0.132,0.006,44139.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-13",24,24,5635,,0.013,0.001,2480.5,0.059,0.125,0.006,41742.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-14",24,24,5971,,0.013,0.001,2610,0.059,0.132,0.006,43921.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-15",24,24,6248,,0.014,0.001,2731.3,0.059,0.138,0.006,45958.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-16",24,24,5938,,0.013,0.001,2612.3,0.059,0.132,0.006,43957.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-17",24,24,5788,,0.013,0.001,2550.7,0.059,0.129,0.006,42919.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-18",24,24,6079,,0.013,0.001,2666.6,0.059,0.135,0.006,44875.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-19",24,24,6259,,0.014,0.001,2740.6,0.059,0.138,0.006,46117,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-20",24,24,6206,,0.014,0.001,2719.5,0.059,0.137,0.006,45763.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-21",24,24,5898,,0.013,0.001,2596.8,0.059,0.131,0.006,43695.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-22",24,24,6124,,0.014,0.001,2686.2,0.059,0.136,0.006,45202.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-23",1,0.28,34.16,,0,0.001,16.912,0.059,0.006,0.039,284.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-26",9,8.45,838.4,,0.003,0.001,534.255,0.059,0.13,0.0504,8986.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-27",15,14.03,2826.03,,0.007,0.001,1298.351,0.059,0.117,0.015,21847.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-28",24,24,5781,,0.013,0.001,2536.2,0.059,0.128,0.006,42678.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-29",24,24,5805,,0.013,0.001,2543.1,0.059,0.128,0.006,42791.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-30",24,24,5741,,0.013,0.001,2519.9,0.059,0.127,0.006,42402.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-10-31",24,24,5629,,0.012,0.001,2474.5,0.059,0.125,0.006,41641.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-01",24,24,5627,,0.012,0.001,2471.2,0.059,0.126,0.0061,41582.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-02",24,24,6221,,0.014,0.001,2698.2,0.059,0.136,0.006,45404.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-03",24,24,6283,,0.014,0.001,2733.2,0.059,0.138,0.006,45988.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-04",22,21.24,4890.36,,0.011,0.001,2175.128,0.059,0.129,0.0075,36601.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-05",24,24,6263,,0.014,0.001,2722.3,0.059,0.135,0.0059,45808.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-06",1,0.37,48.1,,0,0.001,22.792,0.059,0.006,0.03,383.727,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-10",12,11.65,1404.8,,0.004,0.001,866,0.059,0.125,0.0347,14573.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-11",24,24,5645,,0.012,0.001,2467.4,0.059,0.123,0.0059,41518,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-12",24,24,5644,,0.012,0.001,2464.9,0.059,0.124,0.006,41476.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-13",21,20.05,4767.85,,0.011,0.001,2090.225,0.059,0.117,0.0088,35175.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-14",18,17.34,3539.05,,0.008,0.001,1599.912,0.059,0.112,0.0146,26923.689,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-15",19,18.2,4200.49,,0.009,0.001,1856.414,0.059,0.107,0.0088,31237.317,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-16",24,24,5882,,0.013,0.001,2558.4,0.059,0.128,0.006,43051,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-17",24,24,5997,,0.013,0.001,2607.3,0.059,0.132,0.006,43870.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-18",24,24,5542,,0.012,0.001,2420.6,0.059,0.125,0.0062,40730.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-19",24,24,5081,,0.011,0.001,2260.1,0.059,0.113,0.006,38031.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-20",24,24,5842,,0.013,0.001,2544.9,0.059,0.128,0.006,42819.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-21",24,24,5755,,0.013,0.001,2517.7,0.059,0.126,0.006,42364.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-22",21,19.1,4561.13,,0.01,0.001,2029.874,0.0591,0.114,0.01,34158.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-23",20,19.53,4521.07,,0.01,0.001,2013.036,0.059,0.131,0.0094,33873.351,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-24",24,24,4988,,0.011,0.001,2231.5,0.059,0.112,0.006,37552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-25",19,17.97,4113.79,,0.009,0.001,1824.297,0.059,0.126,0.0189,30699.844,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-26",17,16.77,3895.84,,0.009,0.001,1730.369,0.059,0.107,0.0087,29116.397,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-27",19,17.78,3750.82,,0.009,0.001,1690.033,0.059,0.123,0.0191,28437.296,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-28",18,16.8,4194.35,,0.009,0.001,1840.11,0.059,0.135,0.0192,30960.805,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-29",9,8.3,2122,,0.005,0.001,920,0.059,0.051,0.009,15481.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-11-30",22,21.6,4581.8,,0.01,0.001,2063.54,0.059,0.156,0.0172,34723.52,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-01",23,21.76,4911.42,,0.011,0.001,2169.592,0.059,0.124,0.0072,36507.694,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-02",24,24,5896,,0.013,0.001,2553.1,0.059,0.128,0.006,42963.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-03",24,24,5691,,0.013,0.001,2476.4,0.059,0.126,0.0061,41668.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-04",24,24,5360,,0.012,0.001,2348.8,0.059,0.119,0.006,39522.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-05",22,21.6,5162.7,,0.011,0.001,2259.7,0.059,0.128,0.0075,38022.03,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-06",24,24,5338,,0.012,0.001,2342.2,0.059,0.118,0.006,39409.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-07",24,24,5665,,0.013,0.001,2477.2,0.059,0.124,0.006,41688.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-08",24,24,5270,,0.012,0.001,2336.4,0.059,0.119,0.0061,39313.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-09",24,24,5310,,0.012,0.001,2352.7,0.059,0.12,0.0061,39588.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-10",24,24,5810,,0.013,0.001,2546.5,0.059,0.127,0.0059,42844.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-11",24,24,5755,,0.013,0.001,2529.2,0.059,0.128,0.006,42562.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-12",24,24,6031,,0.013,0.001,2639.4,0.059,0.133,0.006,44414.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-13",24,24,5410,,0.012,0.001,2399.9,0.059,0.123,0.0061,40387.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-14",24,24,5289,,0.012,0.001,2355.9,0.059,0.119,0.006,39641.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-15",24,24,4945,,0.011,0.001,2224.9,0.059,0.112,0.006,37438.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-16",22,20.78,4245.69,,0.01,0.001,1939.42,0.059,0.108,0.0118,32633.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-17",24,24,4489,,0.01,0.001,2071.9,0.059,0.104,0.006,34865.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-18",24,24,5250,,0.012,0.001,2364.9,0.059,0.121,0.0061,39792.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-19",22,20.93,4951.71,,0.011,0.001,2214.834,0.059,0.126,0.0071,37269.17,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-20",24,24,5296,,0.012,0.001,2376.7,0.059,0.119,0.006,39992.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-21",24,24,6053,,0.013,0.001,2662.2,0.059,0.133,0.0059,44790.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-22",24,24,5271,,0.012,0.001,2367.2,0.059,0.119,0.006,39830.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-23",24,24,5631,,0.013,0.001,2504.1,0.059,0.126,0.006,42132.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-24",24,24,6075,,0.013,0.001,2665.8,0.059,0.135,0.006,44856.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-25",24,24,5476,,0.012,0.001,2429.1,0.059,0.124,0.0061,40874.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-26",24,24,4903,,0.011,0.001,2213.7,0.059,0.112,0.006,37252.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-27",24,24,5322,,0.012,0.001,2371.3,0.059,0.114,0.0058,39901.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-28",24,24,5678,,0.013,0.001,2517.4,0.059,0.121,0.0058,42362.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-29",24,24,5728,,0.013,0.001,2545,0.059,0.126,0.0059,42822.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-30",24,24,4942,,0.011,0.001,2248.9,0.059,0.11,0.0058,37844.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Pastoria Energy Facility",55656,"CT004",,"2020-12-31",24,24,5943,,0.013,0.001,2625.9,0.059,0.124,0.0056,44187.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-03",3,1.62,28.8,,0,0.0007,20.39,0.0593,0.004,0.013,342.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-26",2,1.35,24.45,,0,0.001,18.57,0.0595,0.004,0.017,312.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-14",3,2.57,59.7,,0,0.001,41.594,0.0597,0.005,0.0187,699.087,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-08",1,0.98,21.56,,0,0.001,24.794,0.059,0.01,0.046,417.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-09",2,1,23.25,,0,0.001,15.353,0.059,0.003,0.033,258.183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-24",1,0.03,0,,0,0.001,0.108,0.06,0,0.014,1.803,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-04-30",1,0.92,19.32,,0,0.001,13.248,0.06,0.003,0.03,222.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-01",1,0.43,7.74,,0,0.001,5.504,0.06,0,0.006,92.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-09",2,1.34,26.88,,0,0.001,18.44,0.059,0.004,0.0195,310.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-26",3,2.13,64.61,,0,0.001,38.976,0.0597,0.005,0.0127,655.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-27",7,6.13,164.81,,0.001,0.001,103.608,0.0593,0.01,0.0103,1742.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-01",2,1.3,26.01,,0,0.001,17.771,0.059,0.004,0.021,298.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-03",4,3.07,84.5,,0,0.001,52.668,0.0595,0.007,0.0165,886.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-04",4,3.33,72.64,,0,0.001,48.061,0.0593,0.007,0.0163,808.783,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-09",15,12.58,530.11,,0.002,0.001,298.618,0.0594,0.032,0.0233,5022.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-10",3,2.23,44.92,,0,0.001,30.711,0.0597,0.004,0.0297,515.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-11",3,1.62,31.96,,0,0.001,21.876,0.0593,0.004,0.0257,367.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-14",3,1.33,27.09,,0,0.001,18.398,0.0597,0.003,0.0503,308.967,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-22",3,1.32,26.4,,0,0.001,17.944,0.059,0.005,0.0377,302.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-05",2,1.15,24.95,,0,0.001,16.675,0.0595,0.003,0.0615,280.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-06",7,4.73,113.42,,0,0.001,74.035,0.0596,0.005,0.0103,1244.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-08",7,3.82,98.29,,0,0.001,62.301,0.0593,0.008,0.0379,1048.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-09",3,1.56,30.93,,0,0.001,21.229,0.059,0.002,0.0207,357.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-10",3,1.37,26.44,,0,0.001,18.306,0.059,0.002,0.0447,308.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-11",3,2.6,72.65,,0,0.001,45.465,0.0597,0.007,0.019,764.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-12",3,2.62,67.79,,0,0.001,43.216,0.0597,0.006,0.017,726.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-13",5,2.46,48.87,,0,0.001,33.662,0.0596,0.005,0.0662,565.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-14",4,1.45,26.04,,0,0.001,18.772,0.0595,0.003,0.0213,315.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-17",3,1.35,25.95,,0,0.001,18.205,0.0593,0.002,0.0337,306.634,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-20",3,1.5,28.8,,0,0.001,20.21,0.0597,0.002,0.014,339.365,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-21",3,1.34,25.46,,0,0.001,17.886,0.0593,0.003,0.0377,301.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-23",3,1.4,28.1,,0,0.001,19.313,0.0593,0.003,0.0317,325.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-26",2,1.4,34.88,,0,0.001,22.204,0.0595,0.003,0.0195,373.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-27",4,2.61,53.42,,0,0.001,36.354,0.059,0.004,0.015,612.481,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-28",3,1.35,26.05,,0,0.001,18.156,0.059,0.002,0.0257,305.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-29",5,3.36,69.64,,0,0.001,47.161,0.059,0.004,0.0216,794.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-30",5,3.73,93.56,,0,0.001,59.885,0.0594,0.005,0.0188,1008.905,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-07-31",4,2.56,49.88,,0,0.001,34.52,0.0593,0.003,0.0223,580.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-01",5,3.64,80.15,,0,0.001,52.662,0.0592,0.003,0.0116,886.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-02",3,1.4,28.48,,0,0.001,19.216,0.0597,0.002,0.0187,322.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-03",3,1.43,28.96,,0,0.001,19.475,0.059,0.002,0.022,328.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-05",9,7.32,164.52,,0.001,0.001,107.92,0.0594,0.007,0.0173,1813.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-06",7,5.37,116.35,,0,0.001,77.576,0.0596,0.004,0.0123,1303.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-09",7,3.74,77.07,,0,0.001,51.963,0.0594,0.006,0.0229,875.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-10",7,4.29,90.62,,0,0.001,60.667,0.0591,0.006,0.0196,1020.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-11",3,1.35,27.17,,0,0.001,18.33,0.059,0.002,0.0293,308.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-12",4,2.54,54.87,,0,0.001,36.364,0.0595,0.003,0.0273,611.768,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-13",7,5.61,146.04,,0,0.001,91.72,0.0594,0.008,0.0121,1542.541,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-14",8,6.98,152.67,,0.001,0.001,100.687,0.0595,0.009,0.0119,1692.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-15",7,6.44,150.86,,0,0.001,97.735,0.0596,0.01,0.013,1643.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-16",5,3.8,84.99,,0,0.001,55.621,0.0592,0.003,0.0122,937.847,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-17",10,8.75,197.12,,0.001,0.001,128.148,0.0595,0.01,0.011,2155.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-18",11,9.94,433.69,,0.001,0.001,240.421,0.0592,0.022,0.0115,4045.346,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-19",6,4.3,94.74,,0,0.001,62.039,0.0593,0.006,0.0328,1043.847,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-20",4,2.31,49.43,,0,0.001,32.628,0.0595,0.003,0.0323,548.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-21",4,2.31,49.38,,0,0.001,32.587,0.059,0.003,0.0295,548.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-22",4,2.38,50.66,,0,0.001,33.515,0.0593,0.003,0.0193,564.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-23",4,2.38,50.91,,0,0.001,33.591,0.0593,0.004,0.0223,566.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-24",4,2.36,50.36,,0,0.001,33.203,0.0593,0.004,0.0253,559.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-25",6,3.61,77.95,,0,0.001,51.052,0.0595,0.007,0.0317,859.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-26",7,4.48,98.99,,0,0.001,64.735,0.0591,0.005,0.018,1089.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-27",4,2.38,50.5,,0,0.001,33.553,0.0595,0.003,0.022,563.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-28",4,2.36,47.85,,0,0.001,32.45,0.0595,0.002,0.021,545.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-29",18,15.58,352.35,,0.001,0.001,229.404,0.0594,0.014,0.0151,3858.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-30",14,11.58,255.74,,0.001,0.001,167.915,0.0594,0.01,0.0072,2824.353,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-08-31",4,3.1,67.15,,0,0.001,44.478,0.0593,0.004,0.0103,747.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-01",8,7.23,164.45,,0.001,0.001,107.622,0.0591,0.006,0.0118,1812.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-02",9,6.46,142.69,,0,0.001,94.288,0.059,0.005,0.0127,1588.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-03",8,6.6,148.8,,0,0.001,97.868,0.0594,0.006,0.0093,1647.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-04",4,2.4,52.7,,0,0.001,35,0.0595,0.003,0.0193,589.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-05",5,3.38,73.73,,0,0.001,48.845,0.059,0.003,0.017,822.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-06",7,5.36,144.46,,0,0.001,90.053,0.0594,0.005,0.0146,1515.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-07",5,3.33,78.71,,0,0.001,50.727,0.0596,0.005,0.0224,852.711,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-08",4,2.33,49.78,,0,0.001,33.061,0.0595,0.003,0.0328,555.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-09",19,15.66,346.89,,0.001,0.001,227.975,0.0593,0.014,0.0141,3836.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-10",4,2.33,45.39,,0,0.001,31.469,0.0598,0.003,0.032,528.334,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-14",2,1.32,29.6,,0,0.001,19.38,0.06,0.002,0.018,325.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-15",3,1.32,25.41,,0,0.001,17.53,0.0597,0.002,0.044,294.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-16",3,1.6,31.75,,0,0.001,21.68,0.0597,0.003,0.0183,364.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-17",2,1.35,31.25,,0,0.001,20.61,0.0595,0.005,0.024,346.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-19",11,7.92,207.87,,0.001,0.001,130.397,0.0591,0.009,0.0158,2196.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-20",2,1.38,27.98,,0,0.001,18.694,0.059,0.003,0.022,315.238,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-21",3,1.86,39.37,,0,0.001,26.052,0.0593,0.005,0.019,438.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-23",3,1.6,33.35,,0,0.001,22.34,0.06,0.003,0.021,375.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-28",4,2.9,71.56,,0,0.001,45.442,0.0593,0.005,0.014,765.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-29",4,2.36,50.36,,0,0.001,33.239,0.0593,0.003,0.0248,559.629,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-09-30",6,4.42,97.52,,0,0.001,63.689,0.0592,0.006,0.018,1072.999,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-01",6,4.37,94.35,,0,0.001,62.057,0.0593,0.005,0.0187,1044.499,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-02",6,4.37,92.13,,0,0.001,61.169,0.0598,0.004,0.0185,1027.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-03",4,2.35,64.2,,0,0.001,39.385,0.0598,0.004,0.0288,661.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-04",3,2.1,44.85,,0,0.001,29.565,0.0597,0.004,0.0187,496.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-05",5,4.33,124.09,,0,0.001,74.846,0.0592,0.007,0.0152,1260.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-06",4,2.56,58.09,,0,0.001,37.592,0.0598,0.004,0.0145,631.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-07",3,1.56,32.08,,0,0.001,21.373,0.0593,0.003,0.017,359.381,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-11",9,6.74,148.31,,0,0.001,96.817,0.0594,0.007,0.0178,1627.499,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-12",19,15.71,354.78,,0.001,0.001,228.961,0.0593,0.012,0.0132,3853.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-13",17,13.83,311.54,,0.001,0.001,201.624,0.0595,0.011,0.011,3393.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-14",13,8.79,194.02,,0.001,0.001,127.501,0.0596,0.009,0.0234,2143.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-15",20,16.71,378.61,,0.001,0.001,246.967,0.0594,0.013,0.0127,4152.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-16",20,16.66,370.3,,0.001,0.001,242.522,0.0594,0.015,0.0182,4081.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-17",17,13.72,311.83,,0.001,0.001,202.691,0.0595,0.011,0.0127,3410.421,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-18",14,10.68,239.28,,0.001,0.001,155.494,0.0595,0.008,0.015,2614.699,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-19",16,12.96,288.16,,0.001,0.001,188.994,0.0594,0.011,0.0118,3179.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-20",15,11.67,260.43,,0.001,0.001,168.837,0.0594,0.01,0.0167,2841.609,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-21",4,3.15,67.94,,0,0.001,44.763,0.0598,0.004,0.01,751.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-25",9,5.05,100.21,,0,0.001,67.88,0.0592,0.008,0.0401,1142.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-30",3,1.62,39.2,,0,0.001,28.58,0.0597,0.008,0.0947,481.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-10-31",3,1.4,27.98,,0,0.001,19.029,0.0597,0.004,0.0423,319.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-01",4,2.65,57.13,,0,0.001,37.976,0.059,0.005,0.0183,640.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-02",4,2.6,56.13,,0,0.001,37.361,0.059,0.004,0.0183,629.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-03",5,3.63,79.53,,0,0.001,52.722,0.0592,0.006,0.0166,888.371,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-04",4,2.89,62.49,,0,0.001,41.49,0.06,0.004,0.0145,697.017,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-05",5,3.89,84.93,,0,0.001,55.922,0.0592,0.007,0.016,940.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-06",2,1.27,25.41,,0,0.001,17.064,0.0595,0.005,0.0255,286.739,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-08",4,2.62,55.63,,0,0.001,36.862,0.0593,0.003,0.0138,620.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-09",2,1.32,26.46,,0,0.001,17.844,0.059,0.003,0.017,300.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-10",6,2.74,55,,0,0.001,37.633,0.0592,0.004,0.0258,634.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-15",5,3.44,115.32,,0,0.001,68.298,0.0594,0.007,0.0202,1149.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-16",4,2.47,60.59,,0,0.001,38.681,0.059,0.003,0.0133,650.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-17",4,2.06,41.51,,0,0.001,28.106,0.0598,0.007,0.037,472.487,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-22",3,1.85,38.47,,0,0.001,25.508,0.0593,0.002,0.009,428.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-24",2,1.33,26.41,,0,0.001,17.936,0.059,0.003,0.014,302.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-11-30",2,1.4,28.44,,0,0.001,19.124,0.0595,0.002,0.021,321.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-03",2,1.35,27.39,,0,0.001,18.555,0.059,0.002,0.019,312.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-04",2,1.4,28.34,,0,0.001,19.369,0.0595,0.002,0.017,325.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-05",2,1.37,28.27,,0,0.001,19.067,0.059,0.003,0.0255,320.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-11",4,2.14,38.59,,0,0.001,27.61,0.0593,0.007,0.0765,464.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-12",4,1.72,44.48,,0,0.001,28.364,0.0595,0.001,0.0205,477.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-13",2,1.58,56.16,,0,0.001,32.856,0.059,0.005,0.0195,553.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-14",3,2.02,42.01,,0,0.001,28.277,0.059,0.004,0.0217,476.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-15",3,1.8,35.66,,0,0.001,24.618,0.0593,0.004,0.025,414.501,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-16",8,6.01,117.74,,0,0.001,81.37,0.059,0.012,0.0188,1371.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-19",2,1.34,27.03,,0,0.001,18.316,0.059,0.004,0.019,308.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-22",4,1.04,16.47,,0,0.001,12.392,0.0593,0.009,0.1158,208.917,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-26",2,1.35,25.4,,0,0.001,19.03,0.059,0.003,0.014,320.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-14",3,2.57,59.7,,0,0.001,41.337,0.0593,0.006,0.019,695.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-08",1,0.98,22.54,,0,0.001,24.794,0.06,0.007,0.032,416.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-09",2,1.08,24.2,,0,0.001,16.312,0.059,0.003,0.025,275.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-09",2,1.34,26.88,,0,0.001,18.482,0.0595,0.004,0.021,311.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-26",3,2.13,62.75,,0,0.001,38.132,0.0597,0.005,0.015,640.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-27",7,6.13,163.88,,0.001,0.001,102.351,0.0597,0.013,0.0136,1719.147,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-03",3,2.03,51.54,,0,0.001,32.587,0.059,0.006,0.022,548.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-04",2,1.3,26.4,,0,0.001,17.97,0.059,0.006,0.0325,302.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-09",15,12.57,519.77,,0.001,0.001,290.722,0.0593,0.035,0.0241,4891.037,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-10",3,2.22,45.05,,0,0.001,30.517,0.0593,0.004,0.026,514.441,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-11",3,1.62,31.96,,0,0.001,21.856,0.0597,0.004,0.0293,366.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-22",3,1.32,25.4,,0,0.001,17.468,0.0597,0.003,0.0273,293.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-09",3,1.66,32.56,,0,0.001,22.52,0.0593,0.006,0.0577,378.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-10",3,1.35,26.2,,0,0.001,18.2,0.0593,0.004,0.0513,306.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-11",3,2.6,72.35,,0,0.001,44.895,0.0593,0.009,0.0263,756.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-12",3,2.62,67.79,,0,0.001,42.647,0.0593,0.008,0.0213,717.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-13",3,1.33,25.9,,0,0.001,17.844,0.06,0.004,0.0587,299.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-14",3,1.23,23.4,,0,0.0007,16.444,0.0593,0.005,0.0367,277.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-20",3,1.5,28.8,,0,0.001,20.16,0.0597,0.002,0.0203,338.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-21",3,1.34,26.12,,0,0.001,18.072,0.0597,0.004,0.0447,303.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-26",2,1.4,33.48,,0,0.001,21.556,0.0595,0.004,0.0305,362.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-27",4,2.61,53.42,,0,0.001,36.254,0.0595,0.005,0.022,610.214,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-28",3,1.35,26.05,,0,0.001,18.11,0.06,0.003,0.04,304.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-29",5,3.36,69.64,,0,0.001,47.138,0.0596,0.033,0.0758,791.726,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-30",5,3.73,90.64,,0,0.001,58.419,0.0592,0.007,0.0258,983.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-07-31",4,2.56,50.88,,0,0.001,34.764,0.0593,0.005,0.0458,585.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-01",3,1.28,24.8,,0,0.001,17.108,0.059,0.003,0.038,288.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-02",3,1.4,28.48,,0,0.001,19.076,0.059,0.003,0.032,321.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-03",3,1.43,28.53,,0,0.001,19.417,0.059,0.003,0.034,326.637,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-10",3,2.02,41.86,,0,0.001,28.006,0.0593,0.004,0.0217,471.624,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-11",3,1.34,27.24,,0,0.001,18.418,0.0593,0.003,0.0383,309.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-12",3,1.54,31.87,,0,0.001,21.313,0.0593,0.003,0.043,358.487,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-13",7,5.61,145.04,,0,0.001,91.172,0.0594,0.009,0.0141,1533.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-14",10,8.2,178.97,,0.001,0.001,118.239,0.0597,0.014,0.0231,1985.931,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-15",8,6.57,149.92,,0,0.001,97.353,0.059,0.01,0.0126,1640.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-16",5,3.8,84.72,,0,0.001,55.681,0.0596,0.005,0.0156,935.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-17",10,8.75,197.12,,0.001,0.001,128.749,0.0592,0.011,0.0129,2167.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-18",11,9.94,423.92,,0.001,0.001,236.636,0.0592,0.043,0.0253,3983.854,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-19",6,4.32,94.92,,0,0.001,63.349,0.0597,0.007,0.0263,1063.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-20",4,2.31,49.56,,0,0.001,33.077,0.0593,0.005,0.0365,557.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-21",4,2.31,49.2,,0,0.001,32.992,0.0593,0.005,0.0358,555.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-22",4,2.38,50.91,,0,0.001,34.265,0.0598,0.003,0.023,575.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-23",4,2.38,51.04,,0,0.001,34.229,0.0595,0.004,0.0255,575.065,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-24",4,2.36,50.36,,0,0.001,33.862,0.0598,0.004,0.028,568.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-25",4,2.36,50.36,,0,0.001,33.793,0.059,0.004,0.0215,568.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-26",8,7.22,168.08,,0.001,0.001,110.32,0.0595,0.01,0.0204,1854.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-27",10,8.35,188.56,,0.001,0.001,125.01,0.0594,0.008,0.0124,2103.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-28",9,7.38,165.58,,0.001,0.001,109.885,0.0593,0.009,0.0138,1851.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-29",3,2.15,47.2,,0,0.001,31.705,0.0593,0.002,0.0083,532.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-04",13,12.22,275.3,,0.001,0.001,184.03,0.0595,0.009,0.0095,3095.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-05",6,3.5,74.45,,0,0.001,50.43,0.0593,0.004,0.0152,848.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-06",7,5.36,143.46,,0,0.001,90.502,0.0593,0.006,0.0164,1522.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-07",5,3.33,77.71,,0,0.001,51.28,0.059,0.005,0.0232,865.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-08",4,2.33,49.78,,0,0.001,33.501,0.0593,0.004,0.035,564.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-09",4,2.35,50.25,,0,0.001,33.795,0.0593,0.004,0.033,568.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-10",4,2.33,47.54,,0,0.001,32.168,0.0593,0.004,0.0355,541.349,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-14",2,1.32,29.6,,0,0.001,19.484,0.0595,0.003,0.0195,327.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-15",3,1.32,25.41,,0,0.001,17.76,0.06,0.003,0.0393,298.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-16",3,1.6,32.3,,0,0.001,22.225,0.059,0.003,0.0197,374.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-17",2,1.35,31.25,,0,0.001,20.74,0.059,0.006,0.0295,349.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-19",4,2.75,59.75,,0,0.001,40.215,0.059,0.005,0.0235,676.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-20",2,1.38,27.1,,0,0.001,18.468,0.059,0.003,0.021,311.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-21",3,1.86,37.64,,0,0.001,25.693,0.059,0.005,0.0203,432.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-23",3,1.6,31.9,,0,0.001,22.035,0.0597,0.004,0.0223,370.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-28",4,2.92,71,,0,0.001,46.008,0.0593,0.005,0.0138,773.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-29",4,2.35,50.65,,0,0.001,33.807,0.0593,0.004,0.0315,569.817,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-09-30",6,4.42,97.52,,0,0.001,64.531,0.059,0.007,0.0218,1088.009,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-01",6,4.37,94.35,,0,0.001,62.979,0.0595,0.006,0.0233,1059.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-02",6,4.35,92.05,,0,0.001,61.915,0.059,0.005,0.0213,1041.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-03",4,2.35,63.85,,0,0.001,39.585,0.0598,0.004,0.0295,665.715,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-04",3,2.1,44.85,,0,0.001,29.92,0.0597,0.004,0.0193,502.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-05",5,4.33,122.66,,0,0.001,75.187,0.0592,0.008,0.0164,1266.409,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-06",4,2.56,58.09,,0,0.001,38.005,0.059,0.004,0.015,640.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-07",3,1.56,32.08,,0,0.001,21.672,0.059,0.003,0.019,364.735,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-12",4,2.34,50.08,,0,0.001,33.285,0.059,0.004,0.027,561.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-13",4,2.32,48.26,,0,0.001,32.466,0.0598,0.004,0.0353,546.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-14",9,7.67,172.35,,0.001,0.0009,113.415,0.0596,0.01,0.009,1907.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-15",5,3.55,77.63,,0,0.001,51.78,0.0592,0.005,0.0158,870.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-16",6,4.32,90.88,,0,0.001,61.582,0.0592,0.007,0.027,1035.731,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-17",5,3.35,70.22,,0,0.001,47.378,0.059,0.004,0.0256,798.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-19",4,2.35,50.35,,0,0.001,33.865,0.0598,0.004,0.0295,568.791,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-25",1,0.13,0,,0,0.001,0.65,0.06,0.001,0.138,10.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-30",3,1.23,35,,0,0.0007,21.776,0.059,0.007,0.1027,366.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-10-31",4,2.59,55.68,,0,0.001,37.418,0.0595,0.004,0.0155,630.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-02",4,2.6,56.13,,0,0.001,38.064,0.0593,0.004,0.0143,639.978,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-04",4,2.89,62.02,,0,0.001,41.88,0.0595,0.005,0.0183,705.757,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-05",5,3.89,85.65,,0,0.001,57.01,0.0594,0.007,0.016,959.793,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-06",2,1.27,25.41,,0,0.001,17.318,0.059,0.005,0.0255,291.523,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-09",2,1.32,26.46,,0,0.001,18.24,0.0595,0.003,0.0135,306.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-10",3,1.37,27.7,,0,0.001,19.272,0.059,0.002,0.026,324.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-15",5,3.46,112.05,,0,0.001,67.776,0.0594,0.007,0.0212,1140.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-16",4,2.47,52.79,,0,0.001,35.748,0.0593,0.003,0.0153,602.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-17",3,1.61,29.96,,0,0.001,21.192,0.06,0.004,0.033,355.629,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-22",3,1.85,37.79,,0,0.001,25.842,0.059,0.002,0.0113,435.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-24",2,1.33,26.41,,0,0.001,18.335,0.059,0.002,0.012,308.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-11-30",2,1.4,28.44,,0,0.001,19.404,0.0595,0.002,0.015,326.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-03",2,1.35,27.39,,0,0.001,18.912,0.059,0.002,0.0175,318.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-04",2,1.4,28.34,,0,0.001,19.702,0.059,0.002,0.016,331.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-05",2,1.37,28.27,,0,0.001,19.341,0.059,0.003,0.021,326.381,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-11",4,2.14,38.22,,0,0.001,27.884,0.0593,0.008,0.0765,469.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-12",4,2.57,83.43,,0,0.001,50.169,0.0593,0.005,0.014,843.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-13",2,1.58,54.58,,0,0.001,32.418,0.059,0.005,0.019,546.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-14",3,2.09,42.24,,0,0.001,29.271,0.0597,0.003,0.0147,492.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-15",3,1.8,35.66,,0,0.001,25.121,0.059,0.003,0.018,423.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-16",6,4.75,100.69,,0,0.001,68.948,0.0598,0.034,0.0655,1157.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-19",2,1.34,27.03,,0,0.001,18.681,0.06,0.003,0.0155,313.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-22",4,1.04,18.99,,0,0.001,13.848,0.0595,0.008,0.1033,232.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Hanford Energy Park Peaker",55698,"HEP2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-14",1,0.12,0,,0,0.001,0.792,0.059,0.001,0.217,13.392,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-03",5,3.92,152.5,,0,0.001,88.761,0.059,0.012,0.0184,1494.826,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-04",5,4.22,191.46,,0.001,0.001,101.346,0.0594,0.015,0.023,1705.954,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-05",6,4.87,230.08,,0.001,0.001,114.235,0.0593,0.007,0.0095,1921.291,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-09",2,1.6,62.24,,0,0.001,37.552,0.059,0.009,0.0305,631.72,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-10",5,4.52,138.47,,0,0.001,88.719,0.0594,0.009,0.0128,1493.336,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-29",3,1.31,49.73,,0,0.001,30.836,0.059,0.008,0.065,519.775,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-26",12,11.09,531.65,,0.001,0.001,276.637,0.059,0.017,0.0087,4657.195,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-27",9,5.45,231.01,,0.001,0.001,122.681,0.0592,0.019,0.0443,2063.447,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-28",10,9.04,502.73,,0.001,0.001,241.494,0.0592,0.018,0.0114,4063.26,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-30",2,0.09,0,,0,0.001,0.595,0.0595,0.001,0.119,9.998,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-01",2,1.87,52.15,,0,0.001,33.071,0.0595,0.009,0.0325,555.752,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-02",4,2.07,61.04,,0,0.001,35.964,0.0595,0.01,0.0355,604.425,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-03",10,9.03,544.21,,0.001,0.001,258.246,0.0594,0.015,0.0152,4344.684,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-04",14,12.63,777.76,,0.002,0.001,370.481,0.0593,0.021,0.0109,6233.12,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-10",9,7.92,425.6,,0.001,0.001,212.808,0.0594,0.016,0.0134,3579.308,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-18",3,1.95,72.53,,0,0.001,39.886,0.0597,0.011,0.0283,670.366,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-22",7,5.82,313.1,,0.001,0.001,151.826,0.059,0.011,0.0126,2555.984,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-23",4,2.7,134.8,,0,0.001,79.69,0.0595,0.01,0.0273,1341.12,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-29",4,2.76,171.59,,0,0.001,83.479,0.059,0.005,0.0098,1405.958,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-09",6,5.38,298.23,,0.001,0.001,152.149,0.0592,0.011,0.0137,2560.99,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-10",10,8.91,498.13,,0.001,0.001,235.698,0.0594,0.013,0.0088,3962.375,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-11",12,11.5,608.5,,0.001,0.001,290.16,0.0594,0.014,0.0073,4880.136,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-12",12,11.23,595.72,,0.001,0.001,287.224,0.0592,0.012,0.0063,4834.154,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-13",9,8,407.27,,0.001,0.001,191.112,0.059,0.012,0.0102,3216.621,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-15",8,6.8,262.26,,0.001,0.001,138.335,0.0594,0.019,0.023,2326.941,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-21",15,14.93,909.76,,0.002,0.001,459.993,0.0592,0.017,0.005,7738.098,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-22",1,0.13,2.21,,0,0.001,1.274,0.059,0,0.004,21.502,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-27",7,6.14,349.56,,0.001,0.001,163.788,0.059,0.012,0.0126,2757.118,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-28",12,11.9,624.6,,0.001,0.001,290.88,0.0592,0.015,0.0075,4896.54,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-29",21,18.49,1008.9,,0.002,0.001,489.082,0.0593,0.015,0.0043,8231.646,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-30",13,12,704.36,,0.002,0.001,326.892,0.0591,0.013,0.0055,5502.644,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-07-31",15,13.35,652.96,,0.002,0.001,314.086,0.0591,0.017,0.007,5286.92,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-01",9,8.11,398.53,,0.001,0.001,191.231,0.0592,0.01,0.0072,3219.284,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-03",7,6.14,262.2,,0.001,0.001,146.77,0.0594,0.011,0.0097,2467.338,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-07",15,13.22,760.36,,0.002,0.001,389.854,0.0593,0.017,0.0148,6559.154,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-08",15,14.05,810.05,,0.002,0.001,411.97,0.0592,0.017,0.0095,6932.605,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-09",19,17.99,1035.36,,0.003,0.001,518.346,0.0592,0.019,0.005,8721.269,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-10",1,0.08,0.24,,0,0.001,0.592,0.06,0,0.034,9.936,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-11",10,9.58,677.62,,0.002,0.001,327.826,0.0591,0.025,0.0124,5516.584,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-12",16,14.68,907.12,,0.002,0.001,449.325,0.0591,0.02,0.0063,7560.696,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-13",11,9.85,565.26,,0.001,0.001,258.467,0.0594,0.021,0.0208,4348.779,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-14",18,17.3,1189.9,,0.003,0.001,552.398,0.0591,0.024,0.007,9295.752,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-15",10,8.73,605.36,,0.001,0.001,281.798,0.0591,0.016,0.0115,4738.035,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-16",18,17.3,1249.84,,0.003,0.001,580.178,0.059,0.023,0.0067,9762.394,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-17",15,14.42,1042.21,,0.002,0.001,485.844,0.0591,0.022,0.0086,8176.295,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-18",24,24,1663,,0.004,0.001,768.8,0.0593,0.03,0.0047,12930.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-19",24,24,1917,,0.004,0.001,879.6,0.0591,0.037,0.005,14797.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-20",24,24,1737,,0.004,0.001,796.9,0.059,0.021,0.0033,13414.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-21",17,16.7,921.3,,0.002,0.001,433.462,0.0592,0.016,0.0053,7293.833,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-22",12,10.86,569.09,,0.001,0.001,270.776,0.0595,0.012,0.0059,4553.858,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-23",16,15.08,1002.07,,0.002,0.001,459.459,0.0592,0.015,0.0048,7730.018,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-24",18,17.08,988.4,,0.002,0.001,457.433,0.0591,0.018,0.0054,7699.555,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-25",12,11.9,660.8,,0.002,0.001,308.77,0.0593,0.014,0.0061,5195.91,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-26",11,9.93,495.01,,0.001,0.001,231.927,0.0591,0.012,0.0065,3903.512,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-27",9,8.17,438.68,,0.001,0.001,204.821,0.0591,0.012,0.0087,3446.873,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-28",8,7.85,439.55,,0.001,0.001,208.01,0.0593,0.011,0.0074,3501.29,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-04",10,8.67,515.23,,0.001,0.001,253.597,0.0591,0.013,0.0196,4266.951,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-05",15,14.87,1052.32,,0.002,0.001,493.591,0.059,0.018,0.0054,8308.015,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-06",24,24,1670,,0.004,0.001,776.9,0.059,0.019,0.003,13071.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-07",23,22.22,1389.31,,0.003,0.001,662.046,0.0593,0.022,0.0043,11136.827,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-08",17,16.47,1112.35,,0.003,0.001,518.003,0.059,0.018,0.0051,8716.332,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-09",14,11.91,583.13,,0.001,0.001,279.302,0.0596,0.012,0.0066,4698.222,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-15",14,13.25,653.4,,0.002,0.001,336.852,0.0593,0.015,0.0059,5667.753,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-16",16,14.33,669.95,,0.002,0.001,333.598,0.0593,0.014,0.0065,5612.133,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-17",7,5.54,292.78,,0.001,0.001,156.676,0.0593,0.007,0.0097,2636.544,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-18",8,7.05,292.3,,0.001,0.001,156.545,0.0594,0.01,0.008,2634.205,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-19",10,9.28,518.16,,0.001,0.001,276.016,0.0592,0.01,0.0053,4643.048,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-27",4,3.3,144.34,,0,0.001,73.404,0.059,0.01,0.017,1235.762,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-28",18,17.25,971.3,,0.002,0.001,457.17,0.0591,0.023,0.0067,7697.27,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-29",17,15.15,858.17,,0.002,0.0009,409.187,0.0592,0.015,0.0047,6885.032,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-09-30",17,15.16,843.24,,0.002,0.001,410.671,0.0591,0.017,0.0058,6910.054,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-01",14,12.98,731.67,,0.002,0.001,352.133,0.0592,0.014,0.0056,5925.856,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-02",11,9.75,575.98,,0.001,0.001,270.492,0.0593,0.013,0.0085,4551.238,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-04",4,2.96,148.22,,0,0.001,83.391,0.0595,0.011,0.0438,1402.967,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-05",13,11.76,524.31,,0.001,0.001,266.021,0.0592,0.018,0.0129,4477.427,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-06",13,12.25,630.36,,0.002,0.001,313.296,0.0593,0.012,0.0052,5269.293,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-11",2,1.3,31.63,,0,0.001,21.928,0.0595,0.006,0.027,369.053,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-13",21,19.83,1059.5,,0.003,0.001,526.073,0.0591,0.021,0.0091,8855.462,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-14",19,18.05,1020.05,,0.003,0.001,505.482,0.0592,0.019,0.0052,8506.034,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-15",9,8.21,405.16,,0.001,0.001,199.545,0.0592,0.012,0.0084,3358.205,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-16",16,15.97,781.07,,0.002,0.001,363.966,0.0594,0.021,0.0079,6121.209,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-17",16,14.22,681.9,,0.002,0.001,328.826,0.0592,0.013,0.0058,5534.698,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-18",14,10.98,461.99,,0.001,0.001,240.275,0.0592,0.012,0.0069,4045.095,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-19",15,11.72,541.26,,0.001,0.0009,271.178,0.0592,0.02,0.0099,4563.062,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-20",13,11.8,540.32,,0.001,0.001,259.132,0.0594,0.016,0.0087,4359.792,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-21",11,9.21,496.14,,0.001,0.001,235.905,0.0591,0.012,0.0098,3971.831,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-30",1,0.1,0,,0,0.001,0.6,0.059,0.001,0.19,10.14,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-01",12,11.55,527.82,,0.001,0.001,261.218,0.0591,0.029,0.0163,4396.584,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-02",16,14.8,766.45,,0.002,0.001,370.776,0.0592,0.016,0.0091,6238.222,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-03",14,13.29,703.62,,0.002,0.001,336.373,0.0591,0.017,0.007,5662.429,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-04",13,12.3,754.3,,0.002,0.001,350.51,0.0592,0.017,0.0074,5896.41,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-05",16,15.29,831.81,,0.002,0.001,397.473,0.0591,0.015,0.0057,6687.582,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-16",12,10.41,482.44,,0.001,0.001,241.131,0.0592,0.027,0.0257,4058.112,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-19",9,7.84,363.04,,0.001,0.001,184.468,0.0592,0.014,0.0127,3106.092,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-20",17,15.92,834.72,,0.002,0.001,399.72,0.0592,0.019,0.008,6726.332,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-07",15,13.48,701,,0.002,0.001,347.603,0.0591,0.03,0.0191,5852.365,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-08",13,12.58,635.1,,0.002,0.001,308.258,0.0594,0.014,0.0059,5184.562,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-09",8,6.75,355.18,,0.001,0.001,171.073,0.059,0.01,0.0116,2880.88,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-12",11,10.93,607.04,,0.001,0.001,296.319,0.0591,0.021,0.011,4988.04,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-13",13,10.59,539.04,,0.001,0.001,259.002,0.0591,0.014,0.0111,4361.381,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-14",7,6.31,357.58,,0.001,0.001,172.678,0.0591,0.011,0.01,2907.885,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-15",14,13.05,698.45,,0.002,0.001,340.046,0.0593,0.013,0.0062,5719.783,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-16",12,11.31,725.44,,0.002,0.001,341.089,0.0591,0.017,0.0076,5742.216,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-03",6,5.55,282.58,,0.001,0.001,135.24,0.0593,0.016,0.0217,2274.566,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-04",8,6.21,297.12,,0.001,0.001,138.428,0.0593,0.013,0.0164,2328.73,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-05",12,9.63,439.55,,0.001,0.001,206.946,0.0592,0.018,0.0158,3482.463,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-17",21,20.05,843.96,,0.002,0.001,455.062,0.0591,0.03,0.0114,7659.835,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-18",22,21.45,1133.95,,0.003,0.001,501.685,0.0592,0.028,0.0084,8443.635,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-19",6,5.05,227.26,,0.001,0.001,103.677,0.0593,0.007,0.0082,1744.608,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-29",5,3.75,181.98,,0.001,0.001,99.179,0.0592,0.014,0.0264,1667.744,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-04-30",3,2.45,74.99,,0,0.001,40.567,0.059,0.008,0.0347,683.361,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-02",3,1.92,60.04,,0,0.001,32.594,0.059,0.006,0.0183,549.276,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-03",2,1.76,55.44,,0,0.001,30.008,0.0595,0.005,0.021,505.12,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-25",7,5.98,354.94,,0.001,0.001,167.651,0.059,0.013,0.0116,2823.224,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-26",14,11.4,597.76,,0.001,0.001,284.102,0.0592,0.02,0.0146,4778.738,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-27",10,8.45,530.85,,0.001,0.001,245.749,0.0592,0.015,0.0131,4133.557,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-28",16,14.32,705.71,,0.002,0.001,327.031,0.0592,0.014,0.0099,5500.17,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-29",9,7.73,325.52,,0.001,0.001,157.34,0.0596,0.009,0.0104,2645.825,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-01",8,7.65,396.56,,0.001,0.001,197.071,0.0593,0.011,0.0095,3316.033,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-02",8,7.1,461.4,,0.001,0.001,213.97,0.0591,0.009,0.0083,3599.89,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-03",10,9.45,544.21,,0.001,0.001,252.357,0.0592,0.013,0.0084,4245.275,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-04",3,1.16,39.34,,0,0.001,20.004,0.0593,0.013,0.0793,336.046,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-08",2,1.3,38.94,,0,0.001,22.774,0.059,0.011,0.04,383.026,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-10",14,12.14,578.44,,0.001,0.0009,278.988,0.0591,0.014,0.0114,4697.494,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-20",3,2.17,92.79,,0,0.001,51.615,0.059,0.013,0.1163,869.214,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-21",24,24,1453,,0.004,0.001,749.6,0.0593,0.024,0.0038,12610.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-22",22,21.02,1172.3,,0.003,0.001,585.188,0.0594,0.02,0.0039,9840.456,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-23",5,4.3,219.5,,0.001,0.001,113.96,0.0594,0.011,0.0158,1917.09,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-26",9,8.34,433.38,,0.001,0.001,205.742,0.0591,0.009,0.0077,3462.304,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-29",4,3.38,207.2,,0,0.001,97.984,0.0593,0.008,0.01,1649.192,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-07",12,11.97,678.28,,0.002,0.001,328.18,0.059,0.015,0.0083,5521.532,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-08",24,24,1414,,0.003,0.001,673.7,0.0593,0.017,0.0029,11334.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-09",21,20.85,1179.2,,0.003,0.001,564.015,0.0593,0.013,0.0028,9486.56,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-10",14,12.63,639.71,,0.001,0.001,290.324,0.0596,0.01,0.0054,4881.053,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-11",7,5.98,360.14,,0.001,0.001,162.984,0.0591,0.007,0.0094,2743.192,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-12",7,5.83,372.55,,0.001,0.001,166.22,0.059,0.01,0.0103,2796.426,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-13",7,5.8,307.95,,0.001,0.001,136.212,0.0591,0.009,0.01,2293.598,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-17",7,6.85,368.8,,0.001,0.001,175.61,0.0593,0.014,0.0143,2953.365,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-18",24,24,1455,,0.004,0.001,693.6,0.0591,0.026,0.0044,11669.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-19",21,20.25,1120.5,,0.003,0.001,542.95,0.0591,0.02,0.0043,9134.425,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-20",8,7.78,405.96,,0.001,0.001,187.98,0.0593,0.012,0.0104,3162.908,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-21",3,1.77,68.23,,0,0.001,34.898,0.059,0.014,0.0337,588.114,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-22",2,1.45,44.5,,0,0.001,22.54,0.059,0.005,0.033,379.235,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-23",13,12.82,730.32,,0.002,0.001,351.718,0.0592,0.012,0.0061,5919.682,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-24",14,12.92,739.26,,0.002,0.001,355.215,0.0591,0.012,0.0057,5979.516,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-25",24,24,1457,,0.003,0.001,691.8,0.059,0.012,0.002,11645.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-26",24,24,1468,,0.004,0.001,705.2,0.0592,0.012,0.002,11866.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-27",22,21.78,1228.66,,0.003,0.001,578.35,0.0592,0.011,0.0022,9731.354,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-28",15,14.32,728.68,,0.002,0.001,324.892,0.0593,0.012,0.0086,5464.76,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-29",14,12.73,692.09,,0.002,0.001,312.225,0.0592,0.01,0.0059,5254.134,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-30",17,15.94,841.24,,0.002,0.001,378.222,0.0594,0.015,0.0059,6364.519,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-07-31",12,11.88,630.92,,0.001,0.001,287.544,0.0592,0.014,0.0078,4838.58,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-01",22,21.25,1149.5,,0.003,0.001,543.05,0.0591,0.016,0.0035,9139.375,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-02",8,6.34,257.9,,0.001,0.001,124.4,0.0593,0.011,0.023,2094.864,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-04",14,13.5,779.5,,0.002,0.001,374.75,0.0594,0.016,0.0078,6302.45,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-05",1,0.05,1.8,,0,0.001,0.785,0.059,0,0.004,13.23,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-07",3,1.62,49.27,,0,0.001,26.919,0.0593,0.007,0.0803,452.691,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-08",2,1.05,29.4,,0,0.001,16.67,0.059,0.005,0.0235,280.528,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-09",2,1.37,51.12,,0,0.001,27.259,0.059,0.009,0.0315,458.761,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-11",3,0.13,1.9,,0,0.001,1.151,0.0597,0.002,0.206,19.313,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-13",18,18,1177,,0.003,0.001,557,0.0591,0.029,0.0084,9372.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-14",24,24,1472,,0.003,0.001,664.5,0.0593,0.019,0.0034,11183.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-15",13,11.87,747.73,,0.002,0.001,337.621,0.0592,0.016,0.0088,5681.752,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-16",4,3.03,210.42,,0,0.001,96.625,0.059,0.002,0.0025,1626.086,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-17",16,15.5,1075,,0.002,0.001,483.4,0.059,0.019,0.0066,8136.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-18",21,20.27,1258.61,,0.003,0.001,560.244,0.0591,0.019,0.004,9426.868,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-21",11,10.85,616.55,,0.001,0.001,272.27,0.059,0.016,0.0085,4584.695,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-22",10,8.76,475.47,,0.001,0.001,213.07,0.0592,0.016,0.0087,3584.784,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-23",3,0.55,12.32,,0,0.001,6.821,0.059,0.005,0.1373,115.069,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-24",16,14.86,870.38,,0.002,0.001,384.482,0.0592,0.018,0.0068,6470.611,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-25",8,6.91,388.92,,0.001,0.001,170.764,0.0594,0.01,0.0078,2872.637,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-26",15,14.12,683.76,,0.002,0.001,305.344,0.0593,0.012,0.0077,5138.212,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-27",13,11.86,598.75,,0.001,0.001,265.343,0.0592,0.014,0.0084,4464.666,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-28",15,13.9,698.82,,0.002,0.001,314.146,0.0592,0.014,0.006,5284.336,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-29",11,9.57,416.73,,0.001,0.001,193.605,0.0594,0.009,0.0056,3255.821,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-08-31",5,4.11,138.36,,0,0.001,66.897,0.0592,0.007,0.014,1126.467,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-01",8,7.92,396.76,,0.001,0.001,191.416,0.059,0.011,0.0098,3222.372,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-02",24,23.67,1439.78,,0.003,0.001,691.881,0.0592,0.031,0.0054,11639.111,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-03",22,21.35,1245.5,,0.003,0.001,605.7,0.0592,0.02,0.0038,10190.125,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-04",12,10.8,610.9,,0.001,0.001,286.511,0.0591,0.011,0.0066,4821.923,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-05",24,24,1538,,0.004,0.001,703.1,0.0592,0.014,0.0024,11829.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-06",24,24,1650,,0.004,0.001,747,0.0591,0.012,0.002,12567.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-07",20,19.15,1250.04,,0.003,0.001,560.767,0.0592,0.016,0.0042,9434.368,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-08",3,2.57,158.09,,0,0.001,70.047,0.0593,0.001,0.0023,1178.66,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-09",20,19.33,976.55,,0.002,0.001,456.377,0.0592,0.019,0.0052,7680.751,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-15",9,7.99,433.12,,0.001,0.001,194.59,0.0592,0.013,0.009,3272.135,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-16",11,9.6,480.25,,0.001,0.001,220.977,0.0592,0.01,0.0076,3718.372,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-18",5,3.5,120.74,,0,0.001,58.813,0.0594,0.012,0.0238,988.788,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-27",14,11.5,471.74,,0.001,0.001,229.096,0.0592,0.018,0.0256,3854.554,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-28",21,19.55,1066.85,,0.002,0.001,484.03,0.0593,0.018,0.0057,8145.188,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-29",19,17.9,955.25,,0.002,0.001,435.013,0.0592,0.016,0.0057,7319.982,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-09-30",21,19.42,1020.92,,0.002,0.001,469.55,0.0593,0.016,0.006,7900.142,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-01",17,15.95,854.7,,0.002,0.001,389.935,0.0593,0.015,0.006,6560.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-02",17,16.08,804.38,,0.002,0.001,368.242,0.0592,0.013,0.0052,6194.764,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-03",8,7.31,480.7,,0.001,0.001,224.348,0.059,0.01,0.0076,3778.441,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-04",2,0.98,30.4,,0,0.001,15.593,0.0595,0.005,0.0685,262.192,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-05",11,8.84,356.24,,0.001,0.001,168.326,0.0595,0.016,0.0153,2829.267,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-06",8,6.75,380.17,,0.001,0.001,173.883,0.0594,0.006,0.0058,2923.544,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-13",9,8.25,427,,0.001,0.001,196.305,0.0591,0.013,0.0126,3304.08,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-14",12,11.68,645.08,,0.001,0.001,289.044,0.0593,0.012,0.0078,4861.476,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-15",13,11.95,722.6,,0.002,0.001,320.32,0.0592,0.012,0.0052,5388.241,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-16",14,13.7,718.77,,0.002,0.001,316.1,0.0592,0.01,0.0043,5317.664,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-17",11,10.6,541.58,,0.001,0.001,245.032,0.0593,0.01,0.0061,4122.976,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-18",6,4.94,256.18,,0.001,0.001,120.372,0.0592,0.006,0.007,2026.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-19",7,5.92,327.16,,0.001,0.001,149.713,0.0593,0.007,0.0064,2520.44,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-20",7,6.2,296.6,,0.001,0.001,134.99,0.0591,0.007,0.0083,2271.62,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-21",8,6.7,376.9,,0.001,0.001,171.48,0.0591,0.009,0.0089,2885.44,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-22",5,3.97,209.62,,0,0.001,94.366,0.0596,0.014,0.0216,1586.961,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-29",1,0.15,0,,0,0.001,0.36,0.06,0.001,0.283,5.985,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-30",3,2.13,58.79,,0,0.001,34.055,0.059,0.007,0.021,574.665,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-01",8,7.22,375.84,,0.001,0.001,171.288,0.0594,0.008,0.0059,2882.736,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-02",12,10.82,602.69,,0.001,0.001,272.071,0.0593,0.012,0.0076,4577.737,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-03",10,8.85,511.6,,0.001,0.001,228.507,0.0592,0.01,0.0078,3844.318,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-04",11,9.82,627.89,,0.001,0.001,283.702,0.0593,0.01,0.0074,4772.599,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-05",16,14.81,787.27,,0.002,0.001,353.676,0.0593,0.013,0.0056,5949.456,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-16",12,10.03,469.08,,0.001,0.001,221.91,0.0593,0.012,0.0195,3733.557,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-19",9,7.74,374.24,,0.001,0.001,174.896,0.0591,0.011,0.0127,2943.134,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-20",17,16.2,814.5,,0.002,0.001,362.38,0.0592,0.013,0.0049,6100.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-07",14,13.2,676.3,,0.002,0.001,318.499,0.0591,0.013,0.0059,5361.169,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-08",13,12.23,569.34,,0.001,0.001,261.499,0.0592,0.014,0.0065,4398.524,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-09",13,11.7,571.8,,0.001,0.001,263.376,0.0592,0.009,0.0062,4432.161,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-12",7,6.6,413.1,,0.001,0.001,188,0.0591,0.012,0.0099,3164.73,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-13",8,6.95,388.35,,0.001,0.001,173.38,0.0596,0.007,0.0056,2915.385,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-15",9,7.9,506.43,,0.001,0.001,229.116,0.0591,0.009,0.0066,3854.244,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-16",20,18.98,1111.82,,0.003,0.001,502.118,0.0592,0.017,0.0066,8450.694,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-03",11,9.35,439.91,,0.001,0.001,234.885,0.0594,0.022,0.0147,3951.649,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-04",9,7.32,341.12,,0.001,0.001,175.316,0.0593,0.016,0.0141,2949.683,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-05",6,5.3,225.9,,0.001,0.001,118.106,0.0592,0.01,0.0155,1986.12,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-06",9,6.83,276.56,,0.001,0.001,146.866,0.0593,0.014,0.0141,2470.697,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-09",1,0.17,0,,0,0.001,1.105,0.06,0.002,0.241,18.564,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-10",5,4.28,128.34,,0,0.001,84.403,0.0592,0.01,0.02,1420.436,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-17",21,19.38,776.04,,0.002,0.001,458.982,0.0594,0.039,0.0135,7721.457,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-18",22,21.31,1130.19,,0.003,0.001,545.671,0.0592,0.028,0.0082,9181.687,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-19",9,6.6,281.84,,0.001,0.001,153.575,0.0592,0.019,0.0149,2585.97,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-29",8,7.51,326.25,,0.001,0.001,189.26,0.059,0.015,0.012,3187.547,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-04-30",3,2.93,94.25,,0,0.001,60.168,0.06,0.014,0.031,1010.322,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-01",8,7.18,420.42,,0.001,0.001,216.158,0.0591,0.009,0.005,3637.936,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-02",7,6.9,361.5,,0.001,0.001,193.97,0.0591,0.014,0.0126,3263.34,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-03",8,7.02,339.74,,0.001,0.001,185.66,0.0593,0.012,0.0088,3121.905,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-17",5,4.07,200.14,,0.001,0.001,112.039,0.059,0.016,0.0486,1885.879,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-18",24,24,1434,,0.004,0.001,720.6,0.0591,0.019,0.0031,12127.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-19",22,20.9,1196.35,,0.003,0.001,604.615,0.0591,0.02,0.0056,10177.115,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-20",24,23.49,1363.65,,0.003,0.001,690.209,0.0591,0.026,0.0046,11613.378,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-21",7,6.1,337.88,,0.001,0.001,178.446,0.0591,0.009,0.008,3001.664,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-22",8,7.05,406.91,,0.001,0.001,213.29,0.0593,0.012,0.0081,3586.962,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-23",8,7.12,394.2,,0.001,0.001,209.609,0.0591,0.012,0.0075,3528.862,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-24",15,14.17,822.38,,0.002,0.001,420.559,0.0593,0.016,0.0061,7075.297,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-25",23,22.63,1330.42,,0.003,0.001,671.94,0.0591,0.018,0.0032,11308.027,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-26",18,16.05,790.77,,0.002,0.001,413.781,0.0591,0.024,0.0079,6960.872,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-27",10,9.3,599.4,,0.001,0.001,291.16,0.059,0.016,0.0094,4900.53,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-28",17,14.84,726.71,,0.002,0.001,356.876,0.0594,0.015,0.0065,6003.05,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-30",10,9.3,519.7,,0.001,0.001,280.8,0.0592,0.015,0.0124,4726.07,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-05-31",3,2.2,123.2,,0,0.001,63.34,0.059,0.002,0.0033,1066.58,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-02",16,14.3,760.5,,0.002,0.001,383.786,0.0593,0.018,0.0139,6457.542,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-03",18,17.35,946.2,,0.002,0.001,465.88,0.0591,0.017,0.0058,7840.055,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-04",20,18.45,1006.11,,0.002,0.001,493.546,0.0592,0.022,0.008,8304.897,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-10",14,12.28,581.04,,0.002,0.001,301.832,0.0594,0.019,0.0204,5077.268,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-11",6,5.42,208.17,,0.001,0.001,122.43,0.0592,0.012,0.0133,2060.122,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-18",6,4.3,140.63,,0,0.001,86.677,0.0595,0.018,0.0477,1457.115,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-22",11,10.32,529.42,,0.001,0.001,258.714,0.0592,0.016,0.0092,4352.78,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-23",7,6.47,320.84,,0.001,0.001,180.796,0.0591,0.011,0.0099,3043.258,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-29",9,7.91,368.37,,0.001,0.001,194.782,0.0592,0.013,0.0109,3278.609,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-09",10,9.68,502.89,,0.001,0.001,253.263,0.0592,0.018,0.013,4263.974,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-10",14,12.81,655.99,,0.002,0.001,316.814,0.0591,0.013,0.0064,5330.659,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-11",9,8.25,475.8,,0.001,0.001,226.555,0.0593,0.014,0.01,3810.355,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-12",9,7.98,473.22,,0.001,0.001,223.702,0.059,0.015,0.0107,3765.198,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-13",18,17.2,885.54,,0.002,0.001,438.498,0.0593,0.025,0.0095,7377.956,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-14",15,14.73,764.79,,0.002,0.001,391.964,0.0591,0.019,0.0073,6597.09,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-15",3,2.2,124,,0,0.001,61.98,0.0597,0.002,0.0043,1041.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-16",8,7.9,370.9,,0.001,0.001,193.86,0.0594,0.013,0.0101,3260,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-17",20,19.8,1159.2,,0.003,0.001,587.36,0.0593,0.016,0.0033,9878.56,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-24",2,1.35,29.9,,0,0.001,20.365,0.0595,0.015,0.098,342.635,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-27",9,8.18,452.48,,0.001,0.001,217.824,0.0593,0.017,0.0127,3663.172,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-28",21,20.13,1056.43,,0.003,0.001,518.995,0.0593,0.018,0.0088,8729.207,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-29",13,9.4,519.97,,0.001,0.001,253.63,0.0592,0.019,0.0136,4265.779,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-30",11,10.09,619.3,,0.001,0.001,287.582,0.0592,0.016,0.0081,4838.737,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-07-31",10,8.87,477.6,,0.001,0.001,227.508,0.059,0.015,0.0109,3828.453,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-01",7,5.97,303.1,,0.001,0.001,146.798,0.0593,0.009,0.0093,2469.433,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-04",1,0.18,0.54,,0,0.001,1.368,0.059,0.002,0.163,23.148,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-06",1,0.15,0,,0,0.001,0.975,0.059,0.002,0.237,16.44,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-09",8,7.25,378.25,,0.001,0.001,197.95,0.0593,0.018,0.0249,3329.35,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-10",24,24,1497,,0.004,0.001,755,0.0591,0.019,0.003,12705.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-11",24,24,1534,,0.004,0.001,790,0.059,0.031,0.0045,13296.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-12",15,12.55,768.01,,0.002,0.001,375.143,0.0593,0.018,0.0079,6311.895,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-13",9,7.99,468.91,,0.001,0.001,217.268,0.0591,0.013,0.0102,3657.48,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-14",14,13.95,1031.15,,0.002,0.001,480.635,0.059,0.022,0.0073,8090.465,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-15",13,12.79,848.51,,0.002,0.001,406.985,0.0591,0.019,0.0073,6849.159,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-16",21,20.63,1403.66,,0.003,0.001,666.291,0.0592,0.022,0.0047,11207.734,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-17",21,19.62,1345.42,,0.003,0.001,638.61,0.0591,0.023,0.0056,10742.322,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-18",24,24,1669,,0.004,0.001,769.9,0.0593,0.029,0.0045,12951.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-19",24,24,1928,,0.004,0.001,887.3,0.0591,0.03,0.0041,14927.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-20",24,24,1748,,0.004,0.001,808.4,0.0591,0.025,0.0038,13602,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-21",21,20.1,1054.44,,0.003,0.001,504.004,0.0591,0.023,0.006,8483.384,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-22",16,14.7,700.66,,0.002,0.001,347.717,0.0591,0.016,0.0069,5852.092,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-23",20,19.55,1171.86,,0.003,0.001,568.669,0.0592,0.021,0.0054,9569.161,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-24",21,19.87,1113.32,,0.003,0.001,522.316,0.0592,0.02,0.0056,8789.691,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-25",16,15.45,782.25,,0.002,0.001,382.53,0.0591,0.019,0.0086,6439.94,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-26",20,19.33,870.75,,0.002,0.001,425.789,0.0592,0.02,0.0058,7167.137,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-27",17,16.37,820.25,,0.002,0.001,393.494,0.0594,0.018,0.0062,6619.24,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-28",19,18.3,878.45,,0.002,0.001,427.48,0.0592,0.021,0.0061,7192.575,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-29",1,0.1,0.3,,0,0.001,0.78,0.059,0,0.005,13.11,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-03",9,8.68,478.72,,0.001,0.001,246.172,0.0591,0.016,0.0127,4141.172,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-04",24,24,1393,,0.004,0.001,704.3,0.0592,0.025,0.0043,11852.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-05",16,14.75,1042.09,,0.002,0.001,486.727,0.0593,0.018,0.0061,8189.299,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-06",24,24,1695,,0.004,0.001,792.1,0.0591,0.019,0.003,13331,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-07",22,21.73,1387.75,,0.003,0.001,663.719,0.0592,0.024,0.0049,11169.433,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-08",20,18.69,1231.5,,0.003,0.001,584.346,0.059,0.026,0.0069,9835.604,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-09",12,9.24,435.09,,0.001,0.0009,219.108,0.0591,0.016,0.0096,3687.147,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-15",7,5.67,298.27,,0.001,0.001,148.424,0.059,0.015,0.0189,2499.179,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-16",9,7.83,394.33,,0.001,0.001,194.433,0.0592,0.013,0.011,3271.487,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-28",17,15.2,897.25,,0.002,0.001,424.475,0.0592,0.024,0.0149,7141.84,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-29",14,13.05,753.79,,0.002,0.001,360.966,0.0591,0.02,0.0081,6076.526,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-09-30",18,17.13,997.47,,0.002,0.001,487.987,0.0592,0.022,0.0058,8210.506,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-01",17,16.15,853.46,,0.002,0.001,418.999,0.0592,0.021,0.0076,7048.236,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-02",17,15.83,837.54,,0.002,0.001,407.247,0.0591,0.02,0.007,6853.544,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-03",18,16.95,938.9,,0.002,0.001,464.885,0.0592,0.021,0.0062,7821.485,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-05",12,9.02,373.11,,0.001,0.001,191.56,0.0594,0.025,0.0174,3221.679,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-06",10,8.88,486.79,,0.001,0.001,234.496,0.0591,0.013,0.008,3945.462,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-13",12,11.12,553.2,,0.001,0.001,272.396,0.0592,0.019,0.0133,4583.428,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-14",11,9.96,580.6,,0.001,0.001,274.08,0.0591,0.016,0.0083,4611.716,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-15",11,10.2,646.8,,0.002,0.001,301.68,0.0593,0.013,0.0063,5075.34,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-16",15,13.4,676.48,,0.002,0.001,322.74,0.0591,0.023,0.0106,5432.441,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-17",21,19.35,973.45,,0.002,0.001,489.68,0.0593,0.024,0.007,8237.755,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-18",14,12.35,558.61,,0.002,0.001,303.229,0.0592,0.012,0.0061,5101.25,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-19",20,19.17,1003.72,,0.003,0.001,522.512,0.0592,0.022,0.0062,8791.262,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-20",23,22.23,1168.06,,0.003,0.001,584.882,0.0592,0.02,0.0039,9840.481,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-21",14,13.25,633.78,,0.002,0.001,316.348,0.0591,0.013,0.0057,5324.992,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-22",9,7.9,352.94,,0.001,0.001,176.446,0.0591,0.011,0.0088,2970.776,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-24",8,7.09,383.69,,0.001,0.001,202.435,0.0591,0.014,0.0098,3405.316,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-25",10,8.17,454.95,,0.001,0.0009,248.948,0.0593,0.015,0.0134,4188.274,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-29",1,0.13,0,,0,0.001,0.845,0.059,0.002,0.23,14.274,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-01",6,5.32,289.6,,0.001,0.001,137.992,0.0592,0.016,0.0173,2321.488,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-02",10,8.91,519.82,,0.001,0.001,245.607,0.0591,0.017,0.0117,4134.13,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-03",20,18.17,978.04,,0.002,0.001,484.566,0.0593,0.025,0.0082,8152.022,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-04",20,18.28,1052,,0.003,0.001,507.088,0.0594,0.024,0.0094,8529.669,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-05",11,10.12,584.5,,0.001,0.001,274.082,0.059,0.018,0.0104,4611.72,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-16",7,6.82,369.52,,0.001,0.001,175.85,0.059,0.024,0.0191,2961.39,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-20",6,5.42,289.2,,0.001,0.001,137.37,0.0592,0.017,0.0223,2310.876,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-07",10,9.08,534.3,,0.001,0.001,254.813,0.0592,0.023,0.014,4285.854,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-08",10,9.07,495.79,,0.001,0.001,236.148,0.0591,0.017,0.0115,3974.581,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-09",13,11.92,588.82,,0.001,0.001,289.242,0.059,0.019,0.0115,4869.446,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-13",12,10.2,525.71,,0.001,0.001,256.047,0.0591,0.011,0.0107,4309.831,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-14",10,9.64,506.04,,0.001,0.001,249.657,0.0591,0.019,0.0112,4200.828,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-15",14,13.32,734.36,,0.002,0.001,355.102,0.0593,0.019,0.0081,5973.792,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-16",20,19.17,1156.34,,0.003,0.001,550.135,0.0592,0.022,0.0069,9259.819,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-04",7,6.35,303.87,,0.001,0.001,153.143,0.059,0.011,0.0107,2577.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-05",3,2.26,102.81,,0,0.001,51.36,0.059,0.008,0.0223,865.114,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-06",9,6.87,279.2,,0.001,0.001,146.979,0.0593,0.011,0.0109,2472.663,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-09",1,0.22,0,,0,0.001,1.474,0.059,0.003,0.252,24.86,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-17",13,10.22,362.52,,0.001,0.001,219.04,0.0593,0.023,0.0242,3685.88,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-18",15,11.9,557.94,,0.001,0.001,283.476,0.0593,0.014,0.009,4768.684,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-19",5,3.04,98.98,,0,0.001,59.348,0.0592,0.007,0.0314,998.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-29",9,7.23,306.31,,0.001,0.001,181.534,0.0592,0.013,0.0242,3055.171,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-25",9,8.13,443.88,,0.001,0.001,233.797,0.0592,0.013,0.0124,3934.212,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-26",4,2.82,150.26,,0,0.001,74.218,0.059,0.005,0.0115,1249.376,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-27",19,18.75,1100.75,,0.003,0.001,554.375,0.059,0.018,0.0052,9328.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-28",13,11.09,586.41,,0.001,0.001,285.085,0.0592,0.011,0.0052,4797.686,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-29",17,14.09,655.41,,0.002,0.001,350.484,0.0592,0.017,0.0075,5897.607,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-30",3,1.72,75.52,,0,0.001,41.492,0.059,0.005,0.0227,698.792,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-02",16,14.28,754.95,,0.002,0.001,381.916,0.0591,0.016,0.0113,6427.458,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-03",18,17.4,935.35,,0.002,0.001,452.99,0.0593,0.014,0.0044,7619.75,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-04",20,18.21,992.6,,0.002,0.001,485.012,0.0592,0.019,0.0067,8163.171,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-10",7,6.1,337.1,,0.001,0.001,168.5,0.059,0.013,0.0117,2837.08,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-11",6,5.36,207.88,,0.001,0.001,121.09,0.0593,0.009,0.0097,2036.882,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-18",4,1.87,39.98,,0,0.0008,30.424,0.0598,0.01,0.0683,511.273,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-22",9,8.05,415.66,,0.001,0.001,202.616,0.0591,0.014,0.013,3410.143,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-23",4,3.1,149.9,,0,0.001,86.7,0.0593,0.007,0.0158,1459.59,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-26",9,8.54,440.74,,0.001,0.001,223.284,0.059,0.01,0.0061,3756.031,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-29",9,7.15,310.8,,0.001,0.001,166.679,0.0591,0.012,0.011,2805.929,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-05",5,4.05,201.05,,0.001,0.001,111.375,0.0592,0.01,0.033,1873.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-06",23,22.17,1326.06,,0.003,0.001,664.108,0.0592,0.02,0.0036,11173.928,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-07",2,0.9,17.6,,0,0.001,13.72,0.0595,0.006,0.025,231.546,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-08",4,3.05,134.75,,0,0.001,66.904,0.0595,0.009,0.0208,1125.226,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-09",8,7.2,385.57,,0.001,0.001,196.309,0.0593,0.01,0.0095,3304.488,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-10",8,6.91,403.35,,0.001,0.001,191.776,0.059,0.011,0.0095,3226.792,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-11",12,11.5,603.5,,0.001,0.001,292.01,0.0591,0.011,0.0059,4917.428,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-12",12,11.23,595.2,,0.001,0.001,286.289,0.0592,0.009,0.0051,4818.088,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-13",14,11.9,550.21,,0.001,0.001,269.83,0.059,0.014,0.0096,4543.035,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-14",10,8.67,372.89,,0.001,0.001,192.418,0.0592,0.011,0.0082,3239.353,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-15",15,14.78,773.72,,0.002,0.001,399.926,0.0593,0.018,0.0061,6727.658,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-16",21,20.33,1117.59,,0.003,0.001,573.414,0.0591,0.018,0.0037,9651.312,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-17",1,0.8,16,,0,0.001,11.28,0.06,0.006,0.061,189.44,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-19",8,7.92,371.68,,0.001,0.001,193.992,0.0591,0.014,0.0106,3265.648,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-20",22,21.35,1223.4,,0.003,0.001,616.13,0.0591,0.016,0.003,10371.32,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-22",13,12.38,722.08,,0.002,0.001,369.654,0.0592,0.015,0.0075,6218.134,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-23",3,1.98,52,,0,0.001,32.5,0.059,0.005,0.0133,547.385,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-27",11,10.82,560.52,,0.001,0.001,269.044,0.0592,0.012,0.0067,4526.33,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-28",15,12.54,636.68,,0.002,0.001,303.133,0.0593,0.016,0.0087,5100.201,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-29",12,10.22,587.17,,0.001,0.001,277.726,0.0594,0.009,0.0059,4671.616,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-30",17,16.09,863.17,,0.002,0.001,411.985,0.0592,0.013,0.0045,6931.68,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-07-31",20,18.27,968,,0.002,0.001,478.955,0.0593,0.016,0.004,8059.224,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-01",12,10.36,490.89,,0.001,0.001,242.121,0.0594,0.011,0.0061,4072.256,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-02",13,12.26,596.62,,0.002,0.001,316.404,0.0591,0.012,0.0051,5325.508,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-03",15,14.4,760.6,,0.002,0.001,415.38,0.0593,0.014,0.0058,6986.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-04",1,0.15,3.3,,0,0.001,1.695,0.06,0,0.003,28.47,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-09",3,0.17,0,,0,0.0007,0.965,0.0597,0.001,0.0663,16.17,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-10",1,0.12,0,,0,0.001,0.804,0.059,0.001,0.218,13.524,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-13",17,15.97,1034.95,,0.003,0.001,508.583,0.0591,0.026,0.0074,8559.872,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-14",24,24,1464,,0.004,0.001,695.2,0.0593,0.019,0.0032,11695.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-15",17,15.92,968.07,,0.002,0.001,476.427,0.0591,0.015,0.0058,8019.525,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-16",22,21.04,1368.85,,0.003,0.001,654.806,0.059,0.015,0.0032,11018.57,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-17",21,19.62,1287.42,,0.003,0.001,604.644,0.0592,0.019,0.0052,10170.134,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-18",24,23.73,1512.63,,0.004,0.001,707.137,0.0592,0.025,0.0042,11899.82,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-19",24,24,1744,,0.004,0.001,812.6,0.0591,0.034,0.005,13675.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-20",24,24,1660,,0.004,0.001,777.1,0.0591,0.016,0.0025,13075,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-21",21,20.12,1024.98,,0.003,0.001,496.582,0.0593,0.014,0.0038,8354.397,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-22",16,15,706.1,,0.002,0.001,350.81,0.0592,0.009,0.0043,5905.52,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-23",20,19.56,1121.19,,0.003,0.001,535.271,0.0592,0.014,0.0037,9006.972,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-24",21,20.05,1095.79,,0.003,0.001,517.404,0.0592,0.014,0.0039,8704.244,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-25",16,15.47,762.75,,0.002,0.001,373.178,0.0591,0.017,0.0069,6279.192,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-26",23,21.72,1067.48,,0.003,0.001,525.112,0.0591,0.018,0.0075,8840.721,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-27",24,24,1302,,0.003,0.001,637.1,0.0591,0.02,0.0037,10720,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-28",24,24,1236,,0.003,0.001,613.1,0.0593,0.022,0.0041,10312.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-29",24,24,1317,,0.003,0.001,665.2,0.0593,0.02,0.0035,11190.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-30",24,24,1449,,0.004,0.001,726.3,0.0592,0.033,0.0054,12220.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-08-31",24,24,1367,,0.003,0.001,691.8,0.0592,0.029,0.005,11637.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-01",20,19.42,1101.5,,0.003,0.001,561.704,0.0591,0.022,0.0044,9453.924,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-04",14,13.5,729.5,,0.002,0.001,365.5,0.0594,0.016,0.0078,6146.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-05",11,11,605,,0.001,0.001,294.1,0.0593,0.008,0.0033,4948.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-06",8,6.57,444.66,,0.001,0.001,216.777,0.0593,0.014,0.0175,3647.599,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-07",3,2.65,111.47,,0,0.001,55.247,0.0597,0.007,0.0183,928.233,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-08",17,16.8,1033.2,,0.003,0.001,497.06,0.0591,0.021,0.0069,8365.46,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-09",16,14.3,686.02,,0.002,0.001,336.144,0.0591,0.011,0.0044,5657.366,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-15",14,13.14,643.39,,0.002,0.001,324.287,0.0594,0.016,0.0064,5453.855,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-16",15,13.88,651.18,,0.002,0.001,329.972,0.0591,0.013,0.0055,5551.063,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-17",3,1.39,39.83,,0,0.001,24.882,0.059,0.005,0.0263,418.779,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-18",7,6.08,258.68,,0.001,0.001,138.202,0.0596,0.009,0.0096,2323.894,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-19",2,1.56,40.56,,0,0.001,27.776,0.059,0.005,0.0165,467.022,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-27",14,11.74,480.66,,0.001,0.001,257.199,0.0595,0.016,0.0135,4324.992,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-28",21,19.38,1007.56,,0.002,0.001,493.497,0.0591,0.018,0.0053,8305.772,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-29",19,18.07,1000.56,,0.002,0.001,481.447,0.0591,0.02,0.0054,8103.58,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-09-30",21,19.55,1054.26,,0.003,0.001,514.453,0.0593,0.017,0.0054,8656.527,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-01",12,11,640.27,,0.002,0.001,307.412,0.0593,0.014,0.0065,5171.59,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-02",13,12.3,687.7,,0.002,0.001,328.01,0.0592,0.019,0.0085,5520.08,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-03",18,16.95,921.2,,0.002,0.001,457.935,0.0592,0.015,0.0043,7706.565,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-05",8,7.62,342.25,,0.001,0.001,175.666,0.0593,0.009,0.0071,2955.116,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-06",13,12.25,633.83,,0.002,0.001,307.734,0.0593,0.011,0.0047,5178.483,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-11",22,21.87,1267.88,,0.003,0.001,674.364,0.059,0.029,0.006,11352.239,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-12",24,23.72,1558.16,,0.004,0.001,807.664,0.0591,0.034,0.005,13587.22,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-13",14,13.33,656.25,,0.002,0.001,318.2,0.0592,0.014,0.0069,5353.29,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-14",15,13.53,705.28,,0.002,0.001,342.053,0.0593,0.014,0.0061,5752.882,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-15",21,19.49,1080.66,,0.003,0.001,536.498,0.0592,0.015,0.0047,9028.15,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-16",20,19.7,950.78,,0.002,0.001,472.87,0.0593,0.014,0.0038,7957.748,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-17",13,11,542.28,,0.001,0.001,265.144,0.0592,0.011,0.0079,4460.807,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-20",11,9.75,454.76,,0.001,0.001,221.567,0.0595,0.011,0.0077,3726.602,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-21",14,13.4,633.22,,0.002,0.001,318.217,0.059,0.011,0.0044,5355.316,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-22",9,8.05,359.3,,0.001,0.001,178.993,0.0592,0.01,0.0077,3014.047,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-29",1,0.13,0,,0,0.001,0.884,0.06,0.001,0.187,14.768,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-30",5,4.66,207.2,,0.001,0.001,116.344,0.0592,0.011,0.0132,1957.732,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-01",12,11.55,529.82,,0.001,0.001,265.411,0.0597,0.014,0.0073,4460.858,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-02",16,14.82,763.46,,0.002,0.001,372.331,0.0593,0.013,0.0058,6264.617,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-03",15,12.46,662.32,,0.002,0.001,318.558,0.0594,0.015,0.0075,5357.678,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-04",18,15.53,867.75,,0.002,0.001,414.769,0.0593,0.015,0.0058,6976.926,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-05",13,12.42,717.87,,0.002,0.001,334.818,0.0592,0.014,0.0059,5635.05,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-20",14,13.49,723.62,,0.002,0.001,341.398,0.0592,0.017,0.0077,5744.222,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-07",8,7.07,416.33,,0.001,0.001,199.339,0.0591,0.014,0.0124,3353.453,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-08",8,6.87,381.58,,0.001,0.001,180.889,0.0591,0.01,0.0095,3045.231,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-09",10,9.1,475.2,,0.001,0.001,224.79,0.0591,0.01,0.0085,3783.45,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-12",11,10.31,549.62,,0.001,0.001,274.96,0.0592,0.013,0.0066,4626.238,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-14",10,9.08,453.38,,0.001,0.001,228.816,0.0591,0.012,0.0073,3851.112,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-15",11,10.13,620.3,,0.001,0.001,293.47,0.0592,0.01,0.0046,4935.104,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-16",10,9.33,634.87,,0.002,0.001,298.611,0.0592,0.01,0.0053,5024.873,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Los Esteros Critical Energy Facility",55748,"CTG4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-13",6,4,115.74,,0,0.001,75.522,0.0593,0.01,0.0155,1270.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-14",3,1.88,63.24,,0,0.001,39.532,0.0593,0.007,0.0317,665.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-24",3,1.88,53.52,,0,0.001,34.408,0.059,0.004,0.017,579.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-26",4,2.61,65.23,,0,0.001,42.863,0.0593,0.007,0.0198,722.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-27",2,1.34,27.67,,0,0.001,19.369,0.059,0.004,0.0305,326.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-01",5,4.38,144.22,,0,0.001,91.521,0.0592,0.012,0.016,1539.257,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-02",3,2.38,103.84,,0,0.001,61.433,0.0593,0.008,0.022,1033.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-03",3,2.68,110.49,,0,0.001,67.119,0.059,0.01,0.0193,1130.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-04",4,2.4,51.5,,0,0.001,36.185,0.0593,0.004,0.024,609.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-08",2,1.35,37.35,,0,0.001,24.615,0.0595,0.004,0.0285,414.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-09",5,3.48,136.1,,0,0.001,83.336,0.0592,0.013,0.0244,1401.362,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-10",3,1.91,75.05,,0,0.001,46.34,0.0593,0.007,0.0267,779.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-11",3,2.13,90.62,,0,0.001,55.275,0.059,0.006,0.0127,929.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-12",5,2.71,77.88,,0,0.001,51.145,0.0596,0.008,0.0322,859.887,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-13",8,6.31,269.68,,0.001,0.001,162.991,0.0591,0.02,0.0201,2743.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-14",6,5.8,239.92,,0.001,0.001,144.788,0.059,0.017,0.0145,2435.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-15",4,2.91,119.32,,0,0.001,72.111,0.0593,0.009,0.0193,1212.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-16",6,4.04,136.67,,0,0.001,85.908,0.0593,0.013,0.0227,1446.167,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-18",2,1.37,26.95,,0,0.001,20.008,0.059,0.004,0.031,336.437,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-19",2,1.34,37.31,,0,0.001,24.899,0.059,0.004,0.0215,419.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-21",4,3.24,129.06,,0,0.001,78.872,0.0593,0.011,0.0198,1327.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-22",3,2.32,53.08,,0,0.001,36.986,0.059,0.005,0.0233,622.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-28",3,2.58,79.07,,0,0.001,50.497,0.059,0.008,0.0177,850.161,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-30",3,1.9,38.02,,0,0.001,27.75,0.059,0.004,0.0327,467.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-04",3,1.35,50.19,,0,0.001,30.848,0.059,0.004,0.0247,519.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-05",5,4.08,119.97,,0,0.001,77.329,0.0598,0.008,0.0168,1299.779,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-07",4,2.61,60.53,,0,0.001,42.062,0.0595,0.005,0.0303,707.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-08",2,1.35,30.7,,0,0.001,21.108,0.0595,0.004,0.025,355.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-09",6,3.29,105.98,,0,0.001,67.468,0.0593,0.01,0.0297,1135.295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-13",3,1.43,54.98,,0,0.001,33.408,0.059,0.006,0.0347,562.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-14",3,1.85,46.05,,0,0.001,30.769,0.0597,0.004,0.0343,517.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-23",2,0.98,24.57,,0,0.001,15.883,0.059,0.003,0.0275,267.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-25",3,2.36,59.68,,0,0.001,38.432,0.0593,0.008,0.0267,646.101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-02",3,1.88,52.16,,0,0.001,32.635,0.0593,0.004,0.031,549.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-04",4,3.14,137.84,,0,0.001,78.056,0.0593,0.01,0.0203,1313.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-07",5,3.3,71.78,,0,0.001,48.324,0.0598,0.004,0.0188,810.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-08",3,1.85,43,,0,0.001,28.427,0.0597,0.005,0.0217,477.709,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-09",4,3.28,132.66,,0,0.001,76.289,0.059,0.01,0.0183,1284.477,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-11",3,2.8,109.24,,0,0.001,63.728,0.0593,0.009,0.0177,1071.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-16",4,2.83,111.27,,0,0.001,63.931,0.0593,0.007,0.0258,1076.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-22",4,2.83,118.08,,0,0.001,67.579,0.0593,0.008,0.0298,1136.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-26",6,5.18,180.24,,0.001,0.001,107.112,0.0598,0.012,0.0147,1799.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-27",4,2.96,95.48,,0,0.001,58.224,0.0593,0.007,0.0283,981.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-28",4,2.39,52.15,,0,0.001,35.503,0.0595,0.005,0.0275,596.219,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-29",4,2.37,50.5,,0,0.001,34.768,0.0593,0.005,0.0353,585.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-01",4,2.27,48.43,,0,0.001,32.821,0.0593,0.004,0.0233,551.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-02",3,1.82,38.21,,0,0.001,25.906,0.06,0.004,0.0303,434.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-03",5,3.32,88.41,,0,0.001,56.009,0.0596,0.009,0.0374,941.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-04",5,3.62,94.5,,0,0.001,60.034,0.0598,0.008,0.0334,1008.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-09",5,3.8,120.76,,0,0.001,73.344,0.0594,0.01,0.0468,1234.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-10",4,3,104.54,,0,0.001,62.536,0.0593,0.008,0.0158,1052.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-11",9,8.88,386.67,,0.001,0.001,218.953,0.0594,0.029,0.0167,3682.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-17",3,1.45,29.3,,0,0.001,20.14,0.059,0.004,0.0403,338.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-23",4,2.59,52.44,,0,0.001,36.535,0.0593,0.009,0.0453,615.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-24",5,3.56,74.44,,0,0.001,50.458,0.0596,0.006,0.0338,848.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-25",3,1.75,50.8,,0,0.001,31.465,0.0593,0.005,0.0337,529.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-26",3,1.62,49.26,,0,0.001,30.368,0.0597,0.004,0.02,510.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-27",4,3.15,117.7,,0,0.001,69.22,0.059,0.011,0.0215,1164.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-01",4,2.9,123.05,,0,0.001,70.485,0.059,0.009,0.0208,1186.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-03",4,2.53,92.83,,0,0.001,54.244,0.0593,0.008,0.0278,913.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-04",4,2.73,113.34,,0,0.001,64.982,0.0595,0.007,0.024,1093.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-05",4,3.38,102.68,,0,0.001,63.568,0.059,0.008,0.0195,1070.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-06",3,1.47,30.94,,0,0.001,20.861,0.059,0.003,0.028,351.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-08",4,2.37,52.8,,0,0.001,34.981,0.059,0.004,0.029,589.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-09",4,3.08,86.92,,0,0.001,54.96,0.0593,0.01,0.0208,924.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-10",3,1.35,27.5,,0,0.001,18.915,0.0593,0.003,0.035,319.035,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-11",8,7.47,298.32,,0.001,0.001,172.599,0.0594,0.02,0.017,2902.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-12",7,6.17,246.53,,0.001,0.001,142.413,0.0593,0.017,0.0144,2398.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-15",3,1.4,28.1,,0,0.001,19.4,0.0593,0.003,0.0303,326.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-16",3,1.4,27.75,,0,0.001,19.149,0.0593,0.004,0.0487,322.646,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-18",4,2.3,69.24,,0,0.001,42.804,0.0595,0.005,0.0323,720,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-20",5,2.97,60.46,,0,0.001,41.578,0.0594,0.006,0.0252,699.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-21",5,3.39,74.07,,0,0.001,49.433,0.0592,0.006,0.0234,833.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-24",3,2.1,45,,0,0.001,30.336,0.059,0.004,0.022,511.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-25",3,1.99,64.48,,0,0.001,39.172,0.059,0.006,0.044,659.489,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-26",5,3.88,159.48,,0,0.001,92.132,0.0594,0.011,0.0168,1549.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-27",5,4.13,159.99,,0,0.001,93.173,0.0596,0.01,0.0182,1565.657,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-28",6,4.93,155.3,,0,0.001,94.947,0.0592,0.014,0.02,1597.589,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-29",4,2.86,87.22,,0,0.001,53.47,0.059,0.007,0.0355,900.045,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-30",5,3.6,89.94,,0,0.001,58.29,0.0592,0.007,0.0334,983.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-07-31",4,2.41,50.97,,0,0.001,34.265,0.0593,0.005,0.0265,577.023,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-02",5,3.39,74.19,,0,0.001,49.885,0.0594,0.006,0.0258,839.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-03",5,3.32,72.6,,0,0.001,48.852,0.0592,0.006,0.0298,822.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-04",3,1.37,27.72,,0,0.001,19.237,0.0593,0.004,0.0407,324.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-09",3,1.89,65.24,,0,0.001,39.457,0.059,0.006,0.0197,663.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-10",2,1.38,52.26,,0,0.001,30.648,0.059,0.006,0.029,515.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-12",3,2.1,74.16,,0,0.001,44.616,0.059,0.005,0.015,751.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-13",8,6.77,212.66,,0.001,0.001,129.991,0.0593,0.013,0.0285,2187.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-14",10,8.95,222.8,,0.001,0.001,144.57,0.0593,0.014,0.0137,2431.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-15",8,6.68,169.05,,0.001,0.001,109.231,0.0595,0.01,0.01,1837.214,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-16",6,4.42,97.79,,0,0.001,66.165,0.0593,0.007,0.0185,1113.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-17",11,9.65,233.39,,0.001,0.001,152.43,0.0594,0.016,0.0145,2564.477,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-18",11,9.92,435.72,,0.001,0.001,248.152,0.0593,0.027,0.0137,4175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-19",7,5.31,117.58,,0,0.001,78.675,0.0594,0.009,0.0269,1322.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-20",5,3.32,72.28,,0,0.001,48.836,0.0594,0.006,0.0326,821.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-21",4,2.33,49.78,,0,0.001,33.868,0.0598,0.004,0.0303,568.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-22",3,1.39,28.19,,0,0.001,19.409,0.0593,0.003,0.0243,327.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-23",3,1.39,27.92,,0,0.001,19.47,0.0593,0.003,0.0287,327.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-24",5,3.35,73.05,,0,0.001,49.214,0.0594,0.006,0.0246,827.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-25",5,3.37,73.6,,0,0.001,49.788,0.0594,0.006,0.0224,838.191,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-26",4,2.33,51.3,,0,0.001,34.813,0.0593,0.006,0.0553,585.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-27",4,2.36,50.59,,0,0.001,34.333,0.0593,0.004,0.0243,577.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-28",4,2.37,50.35,,0,0.001,34.401,0.0593,0.004,0.0233,579.682,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-03",4,2.35,50.28,,0,0.001,34.059,0.0593,0.003,0.0195,572.552,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-04",4,2.4,52.64,,0,0.001,35.316,0.0593,0.004,0.0235,593.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-05",5,3.38,73.91,,0,0.001,49.64,0.0594,0.005,0.021,836.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-06",7,5.37,148.35,,0,0.001,93.075,0.0593,0.009,0.0199,1565.667,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-07",5,3.35,79.08,,0,0.001,52.096,0.0592,0.005,0.0216,877.749,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-08",6,4.37,96.47,,0,0.001,64.549,0.0595,0.007,0.0217,1085.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-09",2,1.33,26.41,,0,0.001,18.259,0.059,0.005,0.0275,307.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-13",4,3.1,113.55,,0,0.001,65.8,0.059,0.008,0.0173,1107.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-14",4,3.5,151.76,,0,0.001,85.304,0.0593,0.01,0.0155,1435.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-16",2,1.35,27.87,,0,0.001,18.756,0.059,0.003,0.0235,316.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-17",4,2.9,82.25,,0,0.001,51.375,0.0593,0.007,0.017,865.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-18",3,1.47,51.18,,0,0.001,30.1,0.0597,0.004,0.0257,505.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-19",4,3.38,136.09,,0,0.001,77.59,0.0595,0.01,0.018,1304.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-20",4,3.35,138.1,,0,0.001,77.985,0.0593,0.008,0.014,1312.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-21",4,2.8,57.94,,0,0.001,39.22,0.0593,0.005,0.0273,660.886,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-22",2,1.6,35.65,,0,0.001,23.672,0.0595,0.006,0.029,397.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-23",2,1.34,26.33,,0,0.001,18.123,0.0595,0.004,0.029,304.487,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-24",2,1.36,26.72,,0,0.001,18.264,0.0595,0.004,0.031,307.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-28",5,4.7,177.32,,0.001,0.001,103.168,0.0594,0.011,0.0162,1735.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-29",5,3.54,119.24,,0,0.001,70.806,0.0594,0.012,0.0466,1191.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-09-30",4,2.77,69.24,,0,0.001,44.488,0.0595,0.006,0.0158,747.598,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-01",5,3.39,81.03,,0,0.001,52.396,0.0592,0.009,0.0184,881.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-02",2,1.6,36.32,,0,0.001,23.896,0.059,0.006,0.0285,402.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-03",3,2.2,87.36,,0,0.001,49.842,0.059,0.009,0.0217,839.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-04",4,3.16,125.32,,0,0.001,71.204,0.0593,0.01,0.018,1197.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-05",8,7.08,319.32,,0.001,0.001,178.425,0.0591,0.018,0.0154,3002.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-06",3,1.85,59.65,,0,0.001,35.91,0.0593,0.007,0.022,604.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-10",2,1.39,27.18,,0,0.001,18.81,0.0595,0.005,0.028,316.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-12",2,1.4,28.34,,0,0.001,19.282,0.0595,0.003,0.021,324.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-13",2,1.32,26.82,,0,0.001,18.075,0.0595,0.003,0.028,303.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-14",3,2.63,95.97,,0,0.001,56.305,0.0597,0.008,0.0153,946.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-15",4,3.07,91.95,,0,0.001,55.717,0.0593,0.006,0.016,938.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-16",2,1.33,28.77,,0,0.001,19.215,0.059,0.004,0.021,323.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-17",2,1.35,33.52,,0,0.001,21.25,0.0595,0.004,0.0265,357.481,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-18",6,2.89,52.32,,0,0.001,37.206,0.0592,0.011,0.1185,626.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-23",2,1.41,40.17,,0,0.001,24.915,0.0595,0.01,0.0755,418.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-24",2,1.43,29.53,,0,0.001,19.82,0.059,0.005,0.041,333.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-25",3,2.12,79.84,,0,0.001,46.516,0.059,0.007,0.022,783.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-26",3,2.12,86.2,,0,0.001,48.86,0.0593,0.007,0.023,822.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-27",2,1.39,45,,0,0.001,27.209,0.0595,0.005,0.0255,457.513,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-28",3,1.4,28.29,,0,0.0007,19.332,0.0593,0.003,0.025,324.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-01",3,1.9,78.4,,0,0.001,44.2,0.059,0.006,0.0203,743.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-02",4,3.44,136.36,,0,0.001,79.332,0.059,0.01,0.019,1333.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-04",4,2.88,61.96,,0,0.001,41.788,0.0593,0.005,0.0185,703.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-05",5,3.89,85.77,,0,0.001,58.188,0.0592,0.008,0.0176,980.137,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-06",3,1.85,38.39,,0,0.001,26.503,0.0593,0.005,0.0267,446.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-09",3,1.37,27.6,,0,0.001,19.224,0.0597,0.003,0.032,323.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-10",4,2.6,55.72,,0,0.001,38.14,0.0593,0.005,0.02,642.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-12",3,1.4,28.46,,0,0.0007,19.384,0.0597,0.004,0.0123,326.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-15",4,3.05,123.17,,0,0.001,71.078,0.0593,0.009,0.016,1196.721,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-16",3,1.6,55,,0,0.001,32.664,0.0593,0.005,0.022,550.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-17",3,1.34,26.68,,0,0.001,18.654,0.0597,0.003,0.0323,314.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-18",3,1.36,26.87,,0,0.001,18.825,0.0597,0.003,0.0377,316.293,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-20",2,1.37,34.77,,0,0.001,22.752,0.0595,0.005,0.0265,382.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-21",3,2.09,44.8,,0,0.001,30.389,0.0593,0.004,0.0213,511.662,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-22",4,2.54,60.04,,0,0.001,39.782,0.0595,0.006,0.023,669.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-24",6,4.15,110.4,,0,0.001,70.243,0.0592,0.01,0.0203,1183.413,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-25",3,2.57,62.17,,0,0.001,40.855,0.0593,0.006,0.0183,686.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-28",2,1.37,28.27,,0,0.001,19.304,0.0595,0.004,0.0275,324.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-29",5,4.38,131.16,,0,0.001,80.94,0.059,0.01,0.0168,1363.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-11-30",5,4.12,184.1,,0.001,0.001,103.686,0.059,0.012,0.0168,1746.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-01",3,2.09,43.71,,0,0.001,29.898,0.059,0.004,0.0213,504.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-02",3,2.42,62.05,,0,0.001,39.934,0.0597,0.005,0.0177,670.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-03",4,2.84,72.86,,0,0.001,46.882,0.0595,0.006,0.0185,788.101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-04",6,4.27,96.93,,0,0.001,64.901,0.0593,0.01,0.018,1093.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-05",4,2.88,62.4,,0,0.001,42.199,0.0595,0.007,0.02,708.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-06",2,1.4,27.48,,0,0.001,19.532,0.06,0.004,0.03,328.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-07",4,3.66,80.86,,0,0.001,54.238,0.0598,0.007,0.0165,911.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-08",2,1.35,31.74,,0,0.001,21.009,0.06,0.005,0.0345,352.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-10",3,2.35,50,,0,0.001,33.904,0.0593,0.004,0.0187,571.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-11",3,2.6,71.09,,0,0.001,44.523,0.059,0.007,0.0227,750.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-12",7,6.07,274.96,,0.001,0.001,154.223,0.0591,0.018,0.0157,2595.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-13",2,1.33,25.25,,0,0.001,17.636,0.059,0.004,0.036,297.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-14",10,7.07,163.7,,0.001,0.001,107.821,0.0592,0.013,0.0202,1816.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-15",6,4.45,115.06,,0,0.001,72.971,0.0595,0.009,0.0193,1226.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-16",3,2.1,80.8,,0,0.001,46.695,0.059,0.006,0.0203,786.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-18",4,2.2,43.17,,0,0.001,29.987,0.0595,0.007,0.0383,504.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-19",3,1.5,30.44,,0,0.001,21.078,0.0597,0.003,0.0247,353.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-20",3,1.4,28.2,,0,0.001,19.724,0.0593,0.003,0.028,331.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-23",2,1.4,34.08,,0,0.001,22.136,0.059,0.005,0.0265,372.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-27",3,2.38,51.02,,0,0.001,34.512,0.059,0.005,0.0203,580.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-28",2,1.37,28.77,,0,0.001,19.915,0.0595,0.004,0.0265,334.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-13",6,3.98,114.68,,0,0.001,75.966,0.0592,0.011,0.0198,1278.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-14",3,1.85,61.75,,0,0.001,39.43,0.0593,0.007,0.0287,663.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-24",3,1.91,55.67,,0,0.001,36.265,0.0593,0.004,0.018,610.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-26",4,2.61,64.62,,0,0.001,43.367,0.0593,0.006,0.018,729.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-27",2,1.34,27.67,,0,0.001,19.724,0.0595,0.004,0.0355,331.591,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-01",5,4.06,130.3,,0,0.001,83.758,0.0594,0.008,0.0142,1408.182,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-02",3,2.38,99.08,,0,0.001,60.812,0.0593,0.007,0.0227,1022.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-03",3,2.43,100.52,,0,0.001,61.724,0.059,0.012,0.0253,1038.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-04",3,1.67,34.56,,0,0.001,25.046,0.059,0.003,0.027,422.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-08",2,1.35,39.15,,0,0.001,26.19,0.06,0.004,0.0305,439.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-09",5,3.49,133.88,,0,0.001,83.343,0.0592,0.013,0.027,1402.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-10",3,1.91,73.62,,0,0.001,46.054,0.059,0.007,0.0263,775.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-11",3,1.93,70.05,,0,0.001,44.368,0.0597,0.006,0.022,745.521,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-12",5,2.7,79.68,,0,0.001,52.879,0.0594,0.007,0.0296,888.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-13",8,6.31,262.87,,0.001,0.001,161.346,0.0596,0.021,0.0216,2711.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-14",6,5.56,229.48,,0.001,0.001,140.652,0.0592,0.015,0.0142,2366.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-15",4,2.91,114.93,,0,0.001,70.898,0.059,0.008,0.0175,1193.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-16",6,3.69,115.91,,0,0.001,75.317,0.0593,0.009,0.0368,1267.177,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-19",2,1.34,37.71,,0,0.001,25.414,0.059,0.004,0.025,427.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-21",4,3.24,125.2,,0,0.001,77.652,0.0593,0.01,0.0183,1306.682,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-22",3,2.32,53.95,,0,0.001,37.505,0.059,0.004,0.0213,631.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-28",3,2.58,78.75,,0,0.001,51.09,0.0597,0.007,0.0147,858.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-30",3,1.9,39.02,,0,0.001,28.656,0.0593,0.004,0.0337,482.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-04",3,1.35,49.19,,0,0.001,30.687,0.0597,0.004,0.0203,516.667,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-05",5,4.06,125.57,,0,0.001,81.041,0.0594,0.008,0.0166,1362.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-07",3,1.36,26,,0,0.001,19.449,0.0593,0.003,0.035,327.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-08",2,1.36,30,,0,0.001,21.168,0.059,0.003,0.022,356.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-09",3,1.9,51.66,,0,0.001,34.274,0.0593,0.004,0.0187,577.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-13",3,1.43,51.46,,0,0.001,32.243,0.0597,0.005,0.0333,542.959,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-14",3,1.6,38.58,,0,0.001,26.71,0.0597,0.004,0.0383,448.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-23",2,0.94,22.44,,0,0.001,14.604,0.059,0.004,0.0305,246.222,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-25",3,2.36,59.68,,0,0.001,38.768,0.059,0.008,0.025,652.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-02",3,1.88,64.41,,0,0.001,38.534,0.0593,0.005,0.037,649.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-04",4,2.89,121.32,,0,0.001,69.854,0.0593,0.009,0.021,1176.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-07",5,3.3,71.74,,0,0.001,49.28,0.0592,0.004,0.0202,829.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-08",3,1.85,42.06,,0,0.001,27.772,0.0593,0.005,0.026,467.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-09",4,3.32,132.47,,0,0.001,76.529,0.059,0.011,0.0208,1287.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-11",3,2.8,107.32,,0,0.001,62.788,0.059,0.01,0.0203,1056.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-16",4,2.83,111.64,,0,0.001,64.231,0.0593,0.007,0.03,1081.035,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-22",4,2.83,117.14,,0,0.001,67.572,0.0593,0.007,0.0363,1136.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-26",6,5.2,179.4,,0.001,0.001,104.4,0.0593,0.011,0.0132,1757.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-27",5,4.65,139.76,,0,0.001,84.642,0.059,0.006,0.0084,1425.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-28",4,2.39,52.37,,0,0.001,34.73,0.0593,0.006,0.0313,584.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-29",3,1.37,27.65,,0,0.001,18.843,0.0593,0.004,0.0517,317.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-01",4,2.32,49.56,,0,0.001,33.367,0.059,0.004,0.0308,562.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-02",3,1.32,26.56,,0,0.001,18.154,0.0593,0.004,0.0333,305.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-03",5,3.32,74.41,,0,0.001,48.815,0.0594,0.008,0.0354,821.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-04",4,2.37,64.5,,0,0.001,38.924,0.059,0.006,0.0428,656.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-09",5,3.8,126.2,,0,0.001,75.096,0.0592,0.01,0.0478,1264.324,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-10",4,3,103.54,,0,0.001,62.074,0.0593,0.008,0.0163,1044.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-11",9,8.85,376.2,,0.001,0.001,211.26,0.0592,0.027,0.016,3555.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-23",4,2.57,59.33,,0,0.001,38.576,0.0593,0.007,0.0463,648.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-24",5,3.55,74.5,,0,0.001,49.591,0.0592,0.007,0.033,835.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-26",6,3.3,107.71,,0,0.001,63.816,0.0597,0.007,0.0283,1072.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-27",3,2.37,89.18,,0,0.001,50.726,0.0593,0.009,0.0257,852.486,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-01",4,2.9,123.5,,0,0.001,69.025,0.059,0.009,0.0225,1162.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-03",4,2.51,94.35,,0,0.001,54.303,0.0593,0.007,0.0275,913.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-04",4,2.78,115.02,,0,0.001,64.869,0.0593,0.008,0.0268,1090.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-05",4,3.13,97.83,,0,0.001,58.617,0.0595,0.008,0.021,985.247,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-06",3,1.47,30.94,,0,0.001,20.582,0.0593,0.003,0.028,346.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-08",4,2.37,65.8,,0,0.001,40.459,0.0595,0.005,0.0348,680.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-09",4,3.08,86.24,,0,0.001,53.268,0.059,0.01,0.0215,897.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-11",8,7.47,295.75,,0.001,0.001,168.33,0.0593,0.015,0.0145,2832.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-12",7,6.17,243.53,,0.001,0.001,139.613,0.0591,0.015,0.0139,2349.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-15",3,1.4,28.1,,0,0.001,19.16,0.059,0.004,0.0397,322.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-16",3,1.4,27.75,,0,0.001,19.009,0.0593,0.003,0.0433,320.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-18",4,2.3,70.06,,0,0.001,42.326,0.0593,0.006,0.036,712.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-20",5,2.97,60.46,,0,0.001,40.908,0.0592,0.006,0.0248,689,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-21",5,2.76,55.51,,0,0.001,37.615,0.06,0.007,0.038,631.479,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-24",4,2.85,62.37,,0,0.001,41.723,0.0595,0.005,0.0198,701.513,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-25",3,2.04,65.29,,0,0.001,39.731,0.059,0.005,0.03,669.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-26",5,3.88,158.48,,0,0.001,89.7,0.059,0.009,0.0152,1510.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-27",5,4.15,158.58,,0,0.001,90.512,0.0592,0.009,0.0192,1522.711,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-28",2,1.37,49.16,,0,0.001,28.514,0.0595,0.006,0.0385,479.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-29",9,7.44,255.1,,0.001,0.001,149.454,0.0594,0.017,0.0256,2513.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-30",5,3.88,96.47,,0,0.001,60.865,0.059,0.007,0.0326,1025.231,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-07-31",4,2.4,50.36,,0,0.001,33.508,0.0598,0.005,0.0338,562.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-02",5,3.39,74.19,,0,0.001,49.104,0.0594,0.006,0.0302,826.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-03",5,3.32,72.6,,0,0.001,48.452,0.0596,0.006,0.0312,814.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-04",3,1.37,27.72,,0,0.001,18.987,0.0593,0.004,0.0443,319.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-09",3,1.9,65.56,,0,0.001,38.674,0.059,0.009,0.0263,650.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-10",2,1.4,51.24,,0,0.001,30.056,0.059,0.006,0.0315,506.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-12",3,2.12,70.9,,0,0.001,41.768,0.059,0.006,0.0203,703.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-13",8,7.21,221.44,,0.001,0.001,133.414,0.0594,0.013,0.0158,2245.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-14",10,8.97,223.22,,0.001,0.001,141.673,0.0591,0.014,0.0141,2384.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-15",8,6.68,169.7,,0.001,0.001,107.525,0.059,0.011,0.0111,1809.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-16",6,4.42,98.06,,0,0.001,64.947,0.0595,0.006,0.0207,1092.963,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-17",11,9.65,227.39,,0.001,0.001,147.939,0.0593,0.015,0.0145,2488.837,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-18",11,9.92,424.92,,0.001,0.001,238.76,0.0592,0.022,0.0119,4018.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-19",7,5.31,117.58,,0,0.001,78.47,0.0593,0.009,0.0287,1319.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-20",5,3.32,72.28,,0,0.001,47.988,0.0594,0.006,0.036,806.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-21",5,3.32,72.6,,0,0.001,47.86,0.0592,0.005,0.0294,805.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-22",3,1.39,28.19,,0,0.001,19.131,0.06,0.003,0.0333,320.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-23",3,1.39,27.92,,0,0.001,19.089,0.0597,0.004,0.0417,320.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-24",5,3.35,73.4,,0,0.001,48.337,0.0594,0.006,0.0288,813.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-25",5,3.37,73.6,,0,0.001,48.814,0.059,0.006,0.0294,823.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-26",4,2.38,55.65,,0,0.001,36.082,0.0598,0.007,0.0603,606.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-27",4,2.36,50.36,,0,0.001,33.616,0.0598,0.005,0.0363,564.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-28",4,2.37,50.6,,0,0.001,34.001,0.0593,0.005,0.0338,571.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-03",4,2.35,50.28,,0,0.001,33.367,0.0595,0.004,0.031,562.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-04",4,2.4,52.76,,0,0.001,34.8,0.0595,0.005,0.0295,585.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-05",5,3.38,73.91,,0,0.001,48.652,0.0592,0.006,0.0302,819.273,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-06",7,5.37,146.47,,0,0.001,90.8,0.0593,0.009,0.0231,1528.045,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-07",5,3.35,79.08,,0,0.001,50.769,0.0596,0.006,0.0312,853.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-08",6,4.37,96.47,,0,0.001,62.875,0.0593,0.007,0.0315,1058.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-13",4,3.1,112.45,,0,0.001,64.84,0.0598,0.005,0.0103,1089.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-14",4,3.5,148.84,,0,0.001,83.028,0.059,0.009,0.0168,1398.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-16",4,2.75,67.96,,0,0.001,43.47,0.0595,0.007,0.0248,730.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-17",4,2.9,82.25,,0,0.001,50.779,0.059,0.006,0.0173,855.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-18",3,1.47,48.54,,0,0.001,28.648,0.059,0.004,0.029,482.727,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-19",4,3.38,134.71,,0,0.001,76.576,0.0595,0.01,0.0183,1287.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-20",4,3.35,136.65,,0,0.001,76.58,0.0593,0.007,0.015,1287.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-21",4,2.8,57.94,,0,0.001,38.624,0.059,0.005,0.0348,650.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-22",2,1.6,35.65,,0,0.001,23.206,0.0595,0.007,0.0365,390.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-23",2,1.32,25.5,,0,0.001,17.505,0.0595,0.004,0.0375,294.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-24",2,1.38,26.22,,0,0.001,18.204,0.0595,0.004,0.034,306.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-28",5,4.7,178.1,,0.001,0.001,100.948,0.0596,0.011,0.0178,1696.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-29",5,3.2,109.66,,0,0.0008,63.894,0.0596,0.013,0.0186,1073.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-09-30",4,2.77,68.24,,0,0.001,43.281,0.059,0.006,0.0168,728.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-01",5,3.39,78.9,,0,0.001,51.351,0.0592,0.01,0.019,863.357,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-02",2,1.6,36.32,,0,0.001,23.664,0.059,0.007,0.0335,399.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-03",3,2.2,85.36,,0,0.001,48.562,0.0593,0.009,0.0233,817.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-04",4,3.16,122.54,,0,0.001,69.876,0.0593,0.01,0.0183,1175.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-05",8,7.08,316.97,,0.001,0.001,175.396,0.0593,0.015,0.014,2950.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-06",4,2.6,76.5,,0,0.001,46.56,0.0598,0.004,0.0163,782.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-08",2,1.4,28.53,,0,0.001,19.165,0.0595,0.005,0.035,322.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-10",2,1.39,27.18,,0,0.001,19.011,0.059,0.005,0.03,321.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-11",2,1.37,26.9,,0,0.001,18.519,0.0595,0.003,0.025,311.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-12",2,1.39,28.67,,0,0.001,19.443,0.059,0.003,0.026,327.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-13",2,1.34,29.08,,0,0.001,19.458,0.0595,0.003,0.0255,327.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-14",3,2.63,93.97,,0,0.001,55.405,0.059,0.008,0.0153,933.577,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-15",4,3.07,90.95,,0,0.001,55.479,0.059,0.005,0.017,934.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-16",2,1.33,31.36,,0,0.001,20.594,0.059,0.005,0.027,346.633,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-17",2,1.38,36.6,,0,0.001,23.094,0.0595,0.007,0.032,388.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-18",6,2.91,51.2,,0,0.001,37.084,0.0595,0.009,0.102,624.169,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-23",2,1.1,32.3,,0,0.001,19.82,0.059,0.01,0.064,334.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-24",2,1.43,29.03,,0,0.001,19.72,0.0595,0.005,0.038,331.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-25",3,2.12,81.58,,0,0.001,46.986,0.0593,0.007,0.0223,790.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-26",3,2.12,80.08,,0,0.001,46.424,0.0593,0.006,0.022,781.276,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-27",2,1.39,45,,0,0.001,27.018,0.0595,0.005,0.0245,453.867,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-28",3,1.4,28.29,,0,0.0007,19.192,0.0593,0.003,0.025,322.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-10-31",3,1.57,32.6,,0,0.001,21.716,0.059,0.003,0.023,365.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-01",3,1.9,77.4,,0,0.001,43.76,0.059,0.007,0.0223,736.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-02",4,3.44,136.36,,0,0.001,78.744,0.0595,0.009,0.0198,1324.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-04",4,2.89,62.69,,0,0.001,41.923,0.059,0.004,0.0135,706.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-05",5,3.9,85.82,,0,0.001,57.821,0.059,0.007,0.0162,974.433,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-06",3,2.09,43.71,,0,0.001,29.815,0.059,0.004,0.0243,501.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-09",3,1.37,27.47,,0,0.001,18.974,0.059,0.003,0.0317,320.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-10",4,2.85,61.78,,0,0.001,41.916,0.0595,0.004,0.0148,704.549,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-12",3,1.4,28.84,,0,0.0007,19.696,0.059,0.003,0.0093,332.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-15",4,3.05,124.17,,0,0.001,70.774,0.0598,0.007,0.013,1189.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-16",3,1.59,54.11,,0,0.001,32.076,0.0593,0.005,0.019,540.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-18",3,1.36,27.1,,0,0.001,18.758,0.059,0.002,0.024,315.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-20",2,1.37,34.77,,0,0.001,22.415,0.059,0.004,0.024,377.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-21",3,2.09,44.8,,0,0.001,30.086,0.0593,0.003,0.0177,506.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-22",4,2.54,55.04,,0,0.001,37.382,0.0595,0.003,0.0155,628.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-24",5,3.63,92.04,,0,0.001,58.919,0.0594,0.006,0.0162,991.417,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-25",3,2.57,60.93,,0,0.001,39.845,0.059,0.004,0.0133,671.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-28",3,1.62,33.6,,0,0.001,22.974,0.0593,0.003,0.0183,387.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-29",6,4.53,135.1,,0,0.001,82.933,0.0597,0.009,0.0157,1394.029,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-11-30",5,4.37,195.43,,0.001,0.001,109.956,0.0594,0.008,0.0126,1848.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-01",4,2.92,59.19,,0,0.001,40.455,0.0595,0.005,0.019,680.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-02",4,3.09,77.03,,0,0.001,49.528,0.0598,0.004,0.012,831.721,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-03",4,2.84,72.86,,0,0.001,46.404,0.059,0.004,0.0135,781.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-04",7,5.03,131.58,,0,0.001,83.72,0.0596,0.009,0.0154,1408.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-05",3,2.38,50.72,,0,0.001,34.105,0.059,0.005,0.018,575.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-06",2,1.4,27.48,,0,0.001,19.132,0.0595,0.004,0.029,321.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-07",4,3.12,68.4,,0,0.001,45.594,0.059,0.004,0.0143,767.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-10",3,2.1,45,,0,0.001,29.85,0.059,0.003,0.017,503.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-11",3,2.6,67.21,,0,0.001,42.592,0.0593,0.004,0.0143,717.185,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-12",4,3.35,149.95,,0,0.001,83.79,0.0593,0.01,0.0165,1408.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-13",2,1.31,24.91,,0,0.001,17.429,0.0595,0.003,0.032,292.977,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-14",8,6.01,138.46,,0,0.001,90.481,0.0593,0.01,0.0139,1521.721,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-15",7,5.83,162.01,,0.001,0.001,100.69,0.0593,0.008,0.0127,1694.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-16",9,6.61,260.68,,0.001,0.001,148.132,0.059,0.015,0.0238,2493.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-18",4,2.2,44.17,,0,0.001,30.335,0.0595,0.005,0.0325,510.637,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-19",3,1.49,30.63,,0,0.001,20.96,0.0593,0.003,0.0213,353.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-20",3,1.4,27.92,,0,0.001,19.44,0.0597,0.002,0.024,326.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-23",2,1.36,26.57,,0,0.001,18.443,0.0595,0.003,0.0195,310.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-27",4,3.01,61.65,,0,0.001,42.376,0.0598,0.004,0.013,712.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-28",2,1.37,28.77,,0,0.001,19.678,0.059,0.003,0.0225,331.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Henrietta Peaker Plant",55807,"HPP2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-16",3,1.22,23.1,,0,0.001,16.908,0.0593,0.007,0.1233,284.178,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-25",2,1.2,18.7,,0,0.001,16.37,0.059,0.008,0.072,275.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-02",2,1.08,18.7,,0,0.001,14.605,0.06,0.008,0.086,245.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-03",2,1.17,12.54,,0,0.001,15.747,0.0595,0.008,0.058,264.768,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-26",3,1.5,24.64,,0,0.001,22.432,0.0593,0.009,0.0897,378.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-04",2,1.23,7.7,,0,0.001,17.205,0.059,0.009,0.0555,289.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-12",2,1.23,13.2,,0,0.001,16.794,0.059,0.008,0.054,282.549,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-14",5,3.92,102.64,,0,0.001,62.55,0.0594,0.013,0.0392,1052.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-17",5,1.96,32.34,,0,0.001,26.817,0.0594,0.016,0.1066,450.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-19",2,1.27,19.14,,0,0.001,18.84,0.0595,0.009,0.08,316.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-29",3,2.2,48.97,,0,0.001,36.675,0.0593,0.01,0.0527,616.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-11",3,1.41,48,,0,0.001,30.197,0.0593,0.008,0.0243,508.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-25",5,3.67,70.8,,0,0.001,55.605,0.0592,0.013,0.0486,936.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-28",2,1.17,20.01,,0,0.001,15.909,0.0595,0.006,0.0655,267.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-29",2,1.24,14.26,,0,0.001,17.05,0.059,0.006,0.0415,287.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-07",4,2.42,47.3,,0,0.001,34.292,0.0595,0.009,0.0698,576.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-09",2,1.64,18.86,,0,0.001,23.534,0.0595,0.008,0.039,395.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-14",2,1.23,18.26,,0,0.001,18.618,0.0595,0.009,0.075,313.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-15",3,2.15,39.16,,0,0.001,30.438,0.059,0.008,0.031,512.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-25",1,0.17,0,,0,0.001,0.969,0.059,0.002,0.208,16.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-29",1,0.3,0,,0,0.001,2.97,0.059,0.004,0.149,50.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-05-31",2,1.58,27.26,,0,0.001,30.524,0.059,0.01,0.0335,513.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-02",4,2.43,43.26,,0,0.001,33.108,0.0598,0.01,0.0588,555.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-03",3,1.75,39.48,,0,0.001,26.698,0.0593,0.01,0.0567,449.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-04",5,2.35,36.96,,0,0.001,28.873,0.0592,0.01,0.0558,485.823,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-09",4,3.07,79.7,,0,0.001,55.365,0.0593,0.013,0.045,931.029,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-10",4,3.5,83.01,,0,0.001,57.108,0.059,0.015,0.0443,961.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-11",7,3.41,40.5,,0,0.001,46.539,0.0591,0.016,0.1011,784.107,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-15",3,1.7,33.2,,0,0.001,22.76,0.0597,0.007,0.0783,382.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-17",3,1.28,24.86,,0,0.001,16.466,0.0597,0.009,0.0987,277.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-18",4,2.52,20.9,,0,0.001,34.563,0.059,0.012,0.038,582.023,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-22",3,1.27,23.4,,0,0.001,15.935,0.059,0.006,0.094,268.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-23",7,5.73,118.76,,0,0.001,81.085,0.0594,0.013,0.0319,1363.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-24",13,11.23,484.72,,0.001,0.001,273.394,0.0592,0.029,0.0297,4599.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-26",7,4.46,86.2,,0,0.001,62.258,0.0593,0.013,0.0471,1048.671,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-29",2,1.28,18.7,,0,0.001,15.819,0.059,0.007,0.0635,266.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-06-30",5,2.31,35.7,,0,0.001,30.037,0.0594,0.012,0.0666,505.359,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-07",3,1.25,22.17,,0,0.001,15.64,0.0593,0.008,0.0903,263.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-08",3,1.33,22.33,,0,0.001,17.312,0.0597,0.004,0.061,290.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-09",6,4.25,92.17,,0,0.001,61.219,0.0592,0.012,0.0502,1030.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-10",3,1.19,23.12,,0,0.001,16.508,0.06,0.006,0.0977,277.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-11",5,3.78,121.68,,0,0.001,73.02,0.0592,0.013,0.0336,1229.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-12",3,1.78,54.6,,0,0.001,36.754,0.0593,0.008,0.0393,618.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-14",5,3.33,66.33,,0,0.001,45.486,0.0592,0.009,0.0356,767.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-17",3,1.27,22,,0,0.001,15.797,0.0597,0.006,0.087,264.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-21",3,1.28,22.13,,0,0.001,16.134,0.0593,0.006,0.0723,272.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-22",2,1.27,17.74,,0,0.001,15.884,0.059,0.006,0.0405,268.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-26",4,2.77,56.62,,0,0.001,40.875,0.0593,0.007,0.0313,687.831,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-27",5,3.93,80.42,,0,0.001,56.635,0.0598,0.01,0.0296,950.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-28",4,2.25,44,,0,0.001,29.915,0.0593,0.006,0.0488,503.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-29",5,3.48,66.9,,0,0.001,47.412,0.0592,0.008,0.049,798.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-30",5,3.53,84.28,,0,0.001,55.283,0.0594,0.01,0.031,930.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-07-31",5,3.18,66.1,,0,0.001,44.692,0.0594,0.009,0.0614,751.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-01",4,2.52,45.64,,0,0.001,33.868,0.0593,0.013,0.0788,570.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-02",3,1.06,10.92,,0,0.001,10.908,0.06,0.006,0.061,182.978,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-03",5,3.18,66.1,,0,0.001,44.722,0.0592,0.009,0.0668,754.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-13",5,4.26,162.72,,0,0.001,96.948,0.0592,0.015,0.0212,1632.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-14",10,8.7,227.1,,0.001,0.001,144.964,0.0592,0.017,0.0189,2439.534,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-15",10,9.17,227.23,,0.001,0.001,153.033,0.0595,0.02,0.0174,2573.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-16",8,6.4,139.23,,0,0.001,95.956,0.0594,0.016,0.0316,1613.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-17",9,7.68,327.2,,0.001,0.001,177.376,0.0591,0.02,0.0304,2983.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-18",14,13.15,365.03,,0.001,0.001,223.584,0.0591,0.021,0.012,3764.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-19",11,9.03,202.75,,0.001,0.001,133.301,0.0591,0.018,0.0343,2243.417,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-20",8,6.17,132.61,,0,0.001,88.705,0.0591,0.011,0.0415,1492.857,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-21",6,4.18,88.18,,0,0.001,58.524,0.0595,0.011,0.0493,983.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-22",4,2.53,48.12,,0,0.001,33.098,0.0595,0.007,0.0543,556.271,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-23",4,2.2,42.7,,0,0.001,29.56,0.0593,0.008,0.0738,498.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-24",6,4.77,95.49,,0,0.001,65.434,0.0595,0.012,0.0417,1101.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-25",8,5.14,100.5,,0,0.001,68.527,0.0593,0.013,0.0491,1153.873,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-26",5,3.33,67.27,,0,0.001,46.063,0.0596,0.009,0.054,773.397,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-27",5,3.28,67.28,,0,0.001,45.124,0.0596,0.008,0.0526,760.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-28",5,3.25,66.51,,0,0.001,44.64,0.0594,0.007,0.0526,751.099,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-30",2,1.25,29.68,,0,0.001,18.78,0.0595,0.006,0.058,316.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-03",4,2.25,43.68,,0,0.001,30.034,0.0593,0.009,0.0713,505.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-04",5,3.22,48.8,,0,0.001,37.946,0.0594,0.006,0.0454,637.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-05",9,7.2,154.92,,0.001,0.001,103.083,0.0596,0.014,0.0332,1732.636,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-06",10,8.23,236.51,,0.001,0.001,142.792,0.0594,0.012,0.0281,2401.787,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-07",8,6.22,134.7,,0,0.001,89.272,0.0595,0.011,0.0395,1501.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-08",8,5.47,123.76,,0,0.001,81.318,0.0594,0.015,0.0465,1367.729,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-09",3,1.2,25,,0,0.001,17.1,0.0593,0.004,0.0833,287.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-10",4,2.18,48.8,,0,0.001,32.27,0.0593,0.006,0.0718,543.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-16",4,2.44,55,,0,0.001,36.228,0.0593,0.008,0.06,608.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-17",2,1.5,30.16,,0,0.001,20.512,0.059,0.005,0.0325,345.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-19",4,3.05,92.5,,0,0.001,54.875,0.0595,0.011,0.0295,922.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-20",3,2.52,50.39,,0,0.001,33.797,0.0593,0.007,0.029,568.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-23",3,1.22,23.06,,0,0.001,16.306,0.059,0.006,0.0913,274.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-24",5,2.95,77.1,,0,0.001,49.084,0.0594,0.017,0.0638,824.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-28",6,4.41,137.22,,0,0.001,82.664,0.0593,0.01,0.0378,1390.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-29",6,4.52,158.49,,0,0.001,91.29,0.0592,0.014,0.0325,1538.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-09-30",8,6.01,130.21,,0,0.001,86.765,0.0594,0.015,0.041,1460.837,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-01",7,5.03,113.25,,0,0.001,73.448,0.059,0.013,0.0279,1236.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-02",5,3.01,76.04,,0,0.001,47.568,0.0594,0.01,0.0294,800.467,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-03",4,2.17,48.08,,0,0.001,31.866,0.059,0.009,0.075,536.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-04",8,4.56,176.84,,0.001,0.001,99.506,0.0595,0.024,0.0774,1674.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-05",5,3.32,78.14,,0,0.001,50.546,0.0592,0.016,0.0644,850.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-06",5,2.97,54.57,,0,0.001,38.99,0.0596,0.011,0.0526,654.923,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-07",4,2.45,50.3,,0,0.001,33.875,0.059,0.007,0.045,570.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-12",1,0.12,0,,0,0.001,0.708,0.06,0.001,0.112,11.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-15",7,6.35,5.92,,0,0.001,40.982,0.0593,0.044,0.126,690.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-16",15,12.78,360.18,,0.001,0.001,225.456,0.0592,0.065,0.0628,3795.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-17",7,4.89,170.2,,0,0.001,98.839,0.0594,0.02,0.0481,1663.709,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-19",9,6.64,200.89,,0.001,0.001,120.04,0.0593,0.02,0.03,2019.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-20",4,2.53,50.22,,0,0.001,33.895,0.0598,0.008,0.0643,570.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-21",4,2.53,50.14,,0,0.001,34.608,0.0598,0.007,0.0463,580.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-02",5,3.5,84.44,,0,0.001,53.166,0.0594,0.01,0.0432,893.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-03",3,1.74,40.17,,0,0.001,25.575,0.059,0.008,0.0483,431.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-04",4,2.97,62.08,,0,0.001,41.132,0.0595,0.009,0.036,691.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-05",7,5.45,116.35,,0,0.001,78.034,0.0593,0.012,0.0257,1313.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-06",6,4.93,223.46,,0.001,0.001,118.801,0.0595,0.017,0.0347,1997.001,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-10",3,2.12,48.39,,0,0.001,30.94,0.0597,0.007,0.045,519.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-12",2,1.07,42.94,,0,0.001,23.211,0.059,0.007,0.052,390.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-15",3,2.68,105.17,,0,0.001,57.88,0.0593,0.011,0.0243,974.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-16",5,3.15,76.2,,0,0.001,47.76,0.059,0.006,0.0372,803.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-19",7,5.42,252.7,,0.001,0.001,136.328,0.0594,0.016,0.025,2293.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-21",3,1.7,36.5,,0,0.001,23.66,0.059,0.01,0.0707,399.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-22",3,1.47,35.13,,0,0.001,22.167,0.059,0.006,0.053,373.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-24",3,1.18,22.36,,0,0.001,15.526,0.0593,0.006,0.0977,262.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-01",8,4.64,103.86,,0,0.001,67.674,0.0596,0.016,0.0778,1136.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-02",4,2.48,55.92,,0,0.001,36.1,0.059,0.008,0.0523,608.552,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-03",3,2.22,45.78,,0,0.001,31.286,0.059,0.008,0.0333,526.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-04",6,4.46,148.3,,0,0.001,86.107,0.0593,0.017,0.028,1447.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-05",2,1.2,23.4,,0,0.001,16.68,0.0595,0.006,0.0395,280.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-09",6,4.45,98.77,,0,0.001,64.769,0.0595,0.013,0.0417,1089.127,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-10",3,1.94,39.69,,0,0.001,27.673,0.0593,0.007,0.0347,465.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-11",4,3.47,96.4,,0,0.001,59.332,0.0593,0.01,0.0265,998.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-12",5,4.2,122.8,,0,0.001,73.5,0.059,0.011,0.0222,1238.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-13",9,5.9,143,,0,0.001,91.37,0.0593,0.017,0.0543,1536.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-14",5,4.2,88.8,,0,0.001,59.96,0.0592,0.011,0.0262,1008.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-15",6,4.7,100.1,,0,0.001,67.36,0.0592,0.011,0.0403,1132.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-16",7,5.67,121.68,,0,0.001,82.419,0.0591,0.014,0.0293,1389.037,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-19",2,1.22,24.03,,0,0.001,16.407,0.0595,0.007,0.0655,275.773,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-27",3,2.48,51.6,,0,0.001,34.132,0.0593,0.009,0.0347,575.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-16",3,1.23,23.5,,0,0.001,17.857,0.0593,0.007,0.099,300.598,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-24",3,1.24,27.92,,0,0.001,19.956,0.0593,0.008,0.083,335.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-03",2,1.19,22.66,,0,0.001,17.094,0.059,0.009,0.06,287.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-04",2,1.25,24.4,,0,0.001,17.135,0.0595,0.008,0.0505,287.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-14",5,2.88,69.46,,0,0.001,47.032,0.0596,0.012,0.0718,790.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-17",5,3.09,58.24,,0,0.001,84.357,0.059,0.032,0.0618,1420.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-29",3,2.22,54.2,,0,0.001,36.354,0.0597,0.011,0.0483,610.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-03-31",3,2.48,50.97,,0,0.001,37.308,0.0593,0.009,0.0327,627.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-10",2,1.22,23.66,,0,0.001,17.42,0.059,0.008,0.0675,293.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-11",3,1.43,52.2,,0,0.001,31.329,0.0597,0.009,0.028,526.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-25",2,1.23,22.77,,0,0.001,17.163,0.059,0.007,0.0465,288.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-07",4,2.43,49.48,,0,0.001,35.143,0.059,0.01,0.0635,591.575,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-09",2,1.53,29.07,,0,0.001,21.42,0.059,0.008,0.048,360.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-15",2,1.17,25.49,,0,0.001,17.955,0.0595,0.008,0.043,301.473,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-25",1,0.17,0,,0,0.001,1.037,0.059,0.002,0.204,17.459,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-29",1,0.3,3.6,,0,0.001,3.24,0.059,0.003,0.101,54.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-05-31",4,2.96,89.86,,0,0.001,56.93,0.059,0.012,0.0403,959.494,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-02",4,2.42,48.04,,0,0.001,35.062,0.0595,0.008,0.0508,590.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-03",4,2.45,79,,0,0.001,48.506,0.059,0.009,0.049,815.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-04",10,9.27,235.72,,0.001,0.001,156.847,0.0591,0.02,0.0219,2641.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-09",6,3.45,103.07,,0,0.001,65.763,0.0597,0.022,0.0772,1105.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-10",4,3.48,85.43,,0,0.001,57.809,0.059,0.015,0.0388,973.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-11",4,2.21,44.86,,0,0.001,32.524,0.0593,0.011,0.0795,547.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-15",3,1.7,34.3,,0,0.001,24.81,0.0593,0.007,0.0683,416.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-18",4,3.07,87.5,,0,0.001,56.118,0.0593,0.012,0.0465,944.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-22",3,1.28,23.1,,0,0.001,17.294,0.0597,0.008,0.097,291.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-25",10,9.42,423.09,,0.001,0.001,242.787,0.0592,0.033,0.0191,4086.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-01",2,1.2,21.3,,0,0.001,15.888,0.059,0.012,0.0935,267.726,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-09",3,1.18,21,,0,0.001,15.81,0.06,0.009,0.071,266.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-10",3,2.06,36.74,,0,0.001,29.07,0.0593,0.006,0.066,489.059,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-11",4,2.8,99.64,,0,0.001,58.986,0.0598,0.012,0.032,992.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-12",4,2.84,85.34,,0,0.001,51.832,0.0593,0.01,0.0365,872.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-16",7,5.32,112.04,,0,0.001,79.384,0.0591,0.012,0.0329,1336.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-22",2,1.28,22.34,,0,0.001,16.837,0.0595,0.007,0.048,283.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-24",2,1.68,35.24,,0,0.001,25.435,0.0595,0.009,0.043,427.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-26",3,1.77,43.48,,0,0.001,28.856,0.0593,0.008,0.048,486.214,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-27",4,2.3,45.3,,0,0.001,32.59,0.0595,0.008,0.0478,548.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-28",4,2.27,43.78,,0,0.001,31.422,0.06,0.007,0.0513,527.349,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-29",5,3.43,67.06,,0,0.001,48.047,0.0594,0.01,0.0536,807.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-30",5,3.53,88.32,,0,0.001,58.568,0.0598,0.012,0.0336,985.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-07-31",5,3.2,67.08,,0,0.001,46.94,0.0596,0.01,0.0582,789.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-01",4,2.52,50.26,,0,0.001,35.612,0.059,0.012,0.0625,600.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-02",4,2.46,75.32,,0,0.001,47.966,0.0595,0.01,0.0645,807.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-03",7,3.42,68.64,,0,0.001,49.38,0.0593,0.011,0.0513,830.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-04",6,4.75,107.39,,0,0.001,76.192,0.0595,0.012,0.0407,1280.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-05",2,1.18,22.9,,0,0.001,16.747,0.0595,0.009,0.073,281.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-06",3,1.8,34.56,,0,0.001,25.212,0.0593,0.009,0.0513,424.236,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-07",3,1.9,36.85,,0,0.001,27.23,0.06,0.008,0.0477,457.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-09",7,5.52,117.29,,0,0.001,82.55,0.0593,0.014,0.0253,1388.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-13",5,4.26,182.73,,0.001,0.001,105.616,0.059,0.016,0.0226,1778.421,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-14",9,7.5,196.5,,0.001,0.001,128.56,0.0594,0.017,0.0179,2162.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-15",10,9.2,243.34,,0.001,0.001,158.57,0.0596,0.024,0.0201,2665.324,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-16",8,5.92,138.21,,0,0.001,94.49,0.0593,0.015,0.0366,1589.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-17",16,14.41,573.59,,0.002,0.001,335.328,0.0592,0.032,0.0244,5647.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-18",16,14.85,406.87,,0.001,0.001,260.788,0.0593,0.022,0.0142,4389.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-19",12,10.41,258.94,,0.001,0.001,172.243,0.0594,0.015,0.0299,2897.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-20",8,6.2,132.8,,0,0.001,93.076,0.0594,0.01,0.0394,1565.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-21",6,4.2,88.3,,0,0.001,62.19,0.0592,0.01,0.0457,1047.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-22",4,2.47,50.86,,0,0.001,36.102,0.0595,0.008,0.05,606.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-23",6,3.4,67.86,,0,0.001,48.988,0.0597,0.015,0.0678,823.477,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-24",6,4.78,99.76,,0,0.001,68.094,0.0592,0.012,0.0393,1146.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-25",5,3.2,66.04,,0,0.0008,45.646,0.0592,0.009,0.0296,769.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-26",5,3.35,65.45,,0,0.001,48.015,0.059,0.009,0.0516,809.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-27",5,3.3,64.7,,0,0.001,48.03,0.0596,0.008,0.0516,807.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-28",5,3.25,66.68,,0,0.001,47.143,0.059,0.007,0.0534,793.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-03",4,2.26,44.72,,0,0.001,32.75,0.0593,0.01,0.0703,551.182,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-04",4,2.2,45.08,,0,0.001,32.176,0.0593,0.007,0.0475,541.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-05",9,7.21,155.23,,0.001,0.001,105.698,0.0598,0.012,0.0252,1776.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-06",10,8.21,217.44,,0.001,0.001,142.112,0.0592,0.014,0.0281,2393.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-07",8,6.12,127.28,,0,0.001,92.43,0.0594,0.009,0.0248,1553.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-08",8,5.38,102.02,,0,0.001,75.554,0.0593,0.012,0.038,1271.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-09",3,1.2,20.7,,0,0.001,14.89,0.0593,0.005,0.0917,250.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-10",4,2.17,40.37,,0,0.001,30.777,0.0593,0.007,0.0675,518.577,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-12",2,1.21,23.06,,0,0.001,17.466,0.06,0.008,0.0465,293.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-15",3,1.16,22.64,,0,0.001,16.856,0.059,0.007,0.1073,283.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-16",4,2.45,44.77,,0,0.001,34.48,0.0595,0.007,0.0613,579.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-17",2,1.5,25.64,,0,0.001,17.948,0.059,0.005,0.0395,302.458,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-19",4,3.07,81.53,,0,0.001,54.395,0.0593,0.011,0.03,915.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-20",3,2.48,49.12,,0,0.001,35.94,0.059,0.009,0.0347,605.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-21",4,2.5,49.88,,0,0.001,36.128,0.059,0.009,0.066,608.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-23",3,1.2,21.9,,0,0.001,16.91,0.0593,0.006,0.094,285.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-24",6,4.49,121.75,,0,0.001,79.877,0.0592,0.025,0.0388,1345.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-28",7,5.45,167.88,,0.001,0.001,103.922,0.0594,0.012,0.0381,1747.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-09-30",8,6.43,132.3,,0,0.001,90.592,0.0591,0.013,0.0396,1526.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-01",7,5.43,119.68,,0,0.001,81.603,0.0594,0.012,0.0446,1371.905,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-02",6,4.05,108.57,,0,0.001,71.071,0.0592,0.01,0.0402,1196.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-03",6,4.45,96.75,,0,0.001,67.65,0.0595,0.011,0.0195,1137.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-04",11,7.7,258.09,,0.001,0.001,159.034,0.0593,0.029,0.0491,2675.089,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-05",5,3.72,95.66,,0,0.001,64.348,0.0596,0.01,0.0282,1082.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-06",4,2.47,49.32,,0,0.001,35.01,0.0593,0.008,0.0485,590.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-07",4,2.45,50.75,,0,0.001,34.8,0.059,0.008,0.0468,586.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-13",1,0.15,0,,0,0.001,0.945,0.06,0.001,0.149,15.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-17",10,7.09,115.95,,0.001,0.001,135.329,0.059,0.039,0.0447,2280.258,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-19",8,6.02,185.8,,0.001,0.001,148.876,0.0593,0.022,0.0254,2505.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-20",4,2.45,50.75,,0,0.001,58.145,0.059,0.013,0.065,978.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-21",4,2.38,51.06,,0,0.001,52.685,0.0595,0.009,0.0413,886.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-02",5,3.49,67.77,,0,0.001,73.834,0.0596,0.011,0.0468,1241.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-03",3,1.84,32.13,,0,0.001,49.42,0.059,0.015,0.046,830.977,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-04",4,3.05,60.8,,0,0.001,80.609,0.059,0.018,0.0348,1355.723,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-05",6,4.4,95.25,,0,0.001,68.34,0.0593,0.013,0.0285,1148.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-06",8,6.48,254.36,,0.001,0.001,150.966,0.059,0.02,0.0295,2541.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-09",3,1.45,29.15,,0,0.001,20.905,0.0597,0.008,0.0907,351.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-10",2,1.2,23.01,,0,0.001,16.482,0.0595,0.007,0.0645,277.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-12",2,1.09,42.26,,0,0.001,24.725,0.06,0.009,0.065,415.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-15",3,2.78,102.42,,0,0.001,75.338,0.059,0.019,0.03,1266.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-16",6,3.93,83.5,,0,0.001,61.929,0.0593,0.019,0.0568,1042.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-19",7,5.42,248.82,,0.001,0.001,139.044,0.0593,0.015,0.0243,2337.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-21",3,1.78,31.28,,0,0.001,48.238,0.059,0.02,0.055,811.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-22",3,1.44,23.3,,0,0.001,39.024,0.059,0.015,0.0287,656.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-01",6,2.97,56.23,,0,0.001,51.083,0.0593,0.021,0.0903,859.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-02",4,2.48,47.98,,0,0.001,35.038,0.0595,0.009,0.0528,589.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-03",3,2.24,45.56,,0,0.001,33.718,0.059,0.009,0.037,567.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-04",6,4.47,135.88,,0,0.001,86.916,0.0592,0.019,0.0308,1464.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-05",2,1.2,20.4,,0,0.001,15.3,0.059,0.006,0.0485,257.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-09",3,2.07,38.65,,0,0.001,28.753,0.0593,0.007,0.0577,484.393,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-10",3,1.95,35.99,,0,0.001,27.598,0.0593,0.007,0.0347,464.633,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-11",4,3.47,90.31,,0,0.001,61.39,0.0598,0.011,0.029,1031.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-12",6,5.2,143.2,,0,0.001,94.76,0.0595,0.014,0.0225,1594.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-13",9,5.9,140,,0,0.001,95.96,0.0593,0.02,0.0524,1615.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-14",5,4.2,87.2,,0,0.001,62.18,0.059,0.012,0.027,1047.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-15",6,4.72,97.5,,0,0.001,71.322,0.0592,0.011,0.039,1200.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-16",5,3.43,73.04,,0,0.001,50.103,0.0596,0.009,0.0554,843.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-27",3,2.57,46.51,,0,0.001,70.418,0.059,0.02,0.0377,1184.513,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-16",3,1.22,23.18,,0,0.001,16.892,0.0593,0.008,0.137,284.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-02",3,1.22,22.94,,0,0.001,16.676,0.0593,0.015,0.1897,281.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-03",2,1.18,22.44,,0,0.001,16.58,0.059,0.009,0.067,279.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-26",2,1.26,26.6,,0,0.001,18.78,0.0595,0.01,0.08,315.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-04",2,1.33,24.13,,0,0.001,20.406,0.059,0.011,0.0595,343.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-14",3,2.01,51.9,,0,0.001,33.498,0.0593,0.011,0.0447,563.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-17",3,1.25,23.67,,0,0.001,17.057,0.0593,0.011,0.1167,287.547,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-19",2,1.35,24.51,,0,0.001,17.44,0.0595,0.01,0.063,292.831,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-29",2,1.23,28.3,,0,0.001,19.175,0.0595,0.01,0.0815,322.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-10",2,1.24,24.43,,0,0.001,17.299,0.059,0.01,0.0835,290.933,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-11",3,1.43,54.2,,0,0.0007,31.007,0.0593,0.01,0.0253,521.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-28",3,1.2,22.76,,0,0.001,16.44,0.06,0.008,0.105,276.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-07",4,2.2,44.48,,0,0.001,31.104,0.0598,0.01,0.112,522.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-08",2,1.21,23.89,,0,0.001,16.785,0.0595,0.009,0.0545,282.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-14",2,1.24,29.28,,0,0.001,19.798,0.0595,0.01,0.0805,333.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-15",2,1.24,32.07,,0,0.001,21.27,0.059,0.007,0.048,358.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-17",1,0.02,0,,0,0,0.014,0.063,0,0,0.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-18",2,0.55,0,,0,0.001,6.705,0.0595,0.002,0.1205,112.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-25",1,0.35,3.15,,0,0.001,3.185,0.06,0.005,0.185,53.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-26",7,6.48,270.44,,0.001,0.001,154.252,0.0591,0.024,0.0229,2595.781,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-27",10,8.44,321.06,,0.001,0.001,186.509,0.0593,0.019,0.0259,3138.295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-29",3,1.17,22.05,,0,0.001,15.667,0.0593,0.007,0.048,263.989,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-05-31",3,2.22,68.38,,0,0.001,41.978,0.0593,0.011,0.035,706.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-02",3,1.2,22.44,,0,0.001,16.06,0.0593,0.005,0.0703,270.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-03",7,3.75,82.66,,0,0.001,55.814,0.0594,0.015,0.1004,939.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-04",7,4.97,110.96,,0,0.001,74.861,0.0597,0.016,0.0457,1258.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-09",6,2.09,61.71,,0,0.0008,38.075,0.0595,0.016,0.124,639.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-10",3,2.18,72.77,,0,0.001,43.823,0.0593,0.011,0.048,738.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-18",2,1.23,31.58,,0,0.001,20.522,0.0595,0.008,0.032,345.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-19",2,1.22,23.1,,0,0.001,16.487,0.059,0.006,0.0435,277.961,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-22",3,1.24,23.2,,0,0.001,16.776,0.0597,0.007,0.105,281.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-23",2,1.85,37,,0,0.001,26.083,0.059,0.007,0.0305,439.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-24",7,5.97,127.13,,0,0.001,86.775,0.0596,0.013,0.0313,1459.698,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-25",7,5.95,127.09,,0,0.001,86.876,0.0594,0.013,0.0356,1462.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-26",11,10.22,438.05,,0.001,0.001,245.135,0.0595,0.029,0.016,4123.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-09",3,1.2,23,,0,0.001,16.33,0.059,0.005,0.0827,275.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-11",5,3.72,129.24,,0,0.001,75.74,0.059,0.014,0.0342,1275.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-12",4,2.75,96.11,,0,0.001,56.344,0.059,0.009,0.0325,949.238,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-18",2,1.21,22.33,,0,0.001,16.159,0.0595,0.007,0.065,271.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-22",2,1.2,25.84,,0,0.001,17.462,0.059,0.007,0.0425,294.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-26",3,1.97,49.92,,0,0.001,32.323,0.059,0.008,0.036,544.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-27",4,2.24,45.32,,0,0.001,31.748,0.0595,0.008,0.0623,534.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-28",4,2.2,44.36,,0,0.001,30.884,0.0595,0.007,0.069,519.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-29",5,3.25,67.67,,0,0.001,46.476,0.0592,0.009,0.0592,782.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-30",5,3.47,90.25,,0,0.001,57.819,0.0598,0.012,0.046,971.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-07-31",5,3.2,66.8,,0,0.001,45.87,0.0594,0.01,0.0586,772.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-01",4,2.45,49.91,,0,0.001,34.543,0.0593,0.015,0.0825,582.413,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-02",4,2.2,44.8,,0,0.001,31.39,0.0593,0.007,0.077,527.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-03",4,2.22,45.3,,0,0.001,31.354,0.0595,0.008,0.079,526.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-08",5,3.79,89.93,,0,0.001,60.149,0.0592,0.012,0.0382,1012.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-09",6,4.52,126.74,,0,0.001,79.264,0.0592,0.012,0.0378,1335.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-10",2,1.16,20.39,,0,0.001,15.215,0.059,0.006,0.0685,256.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-11",2,1.18,21.82,,0,0.001,15.986,0.059,0.006,0.059,269.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-13",5,4.28,179.97,,0.001,0.001,100.767,0.0592,0.015,0.0216,1694.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-14",10,8.74,238.52,,0.001,0.001,149.49,0.0594,0.018,0.02,2515.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-15",10,8.65,238.1,,0.001,0.001,150.256,0.0595,0.02,0.0336,2525.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-16",8,5.63,167.2,,0.001,0.001,103.721,0.0596,0.016,0.0349,1743.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-17",12,10.18,220.16,,0.001,0.001,150.73,0.0593,0.018,0.0378,2536.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-18",14,13.15,371.1,,0.001,0.001,231.797,0.0591,0.022,0.0124,3901.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-19",11,9.9,256.7,,0.001,0.001,164.93,0.0595,0.02,0.0301,2774.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-20",7,5.2,110.8,,0,0.001,75.885,0.0594,0.012,0.0501,1276.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-21",6,3.42,67.64,,0,0.001,47.458,0.0595,0.013,0.07,798.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-22",3,1.2,22.9,,0,0.001,16.29,0.0593,0.007,0.095,274.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-23",6,3.38,66.72,,0,0.001,46.917,0.0595,0.013,0.0672,789.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-24",8,5.38,111.54,,0,0.001,76.883,0.0594,0.018,0.06,1293.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-25",5,3.13,64.22,,0,0.001,44.722,0.0596,0.01,0.0468,751.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-26",5,3.29,68.45,,0,0.001,46.876,0.0592,0.011,0.0584,788.969,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-27",5,3.22,67.06,,0,0.001,46.064,0.0596,0.009,0.0512,774.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-28",5,3.18,66.4,,0,0.001,45.774,0.0594,0.009,0.0684,769.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-30",3,1.23,30.62,,0,0.001,20.022,0.0593,0.008,0.0957,336.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-03",4,2.18,44.56,,0,0.001,31.108,0.0595,0.009,0.0933,522.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-04",5,3.23,48.85,,0,0.001,39.354,0.0592,0.005,0.052,662.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-05",9,7.22,155.04,,0.001,0.001,106.662,0.0594,0.015,0.0342,1793.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-06",10,8.24,220.47,,0.001,0.001,140.066,0.0593,0.017,0.0378,2357.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-07",7,5.13,110.82,,0,0.001,75.45,0.0594,0.015,0.0444,1268.652,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-08",7,4.42,89.84,,0,0.001,62.856,0.0593,0.012,0.0453,1058.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-09",3,1.2,22.8,,0,0.001,16.46,0.0597,0.005,0.0833,276.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-10",4,2.2,44.76,,0,0.001,31.432,0.0595,0.007,0.0735,529.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-16",4,2.21,44.97,,0,0.001,31.695,0.0598,0.008,0.084,532.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-17",2,1.43,27.75,,0,0.001,19.68,0.0595,0.006,0.037,331.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-18",2,1.7,33.15,,0,0.001,23.8,0.059,0.009,0.0455,401.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-19",4,2.74,83.6,,0,0.001,51.62,0.0593,0.011,0.058,868.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-20",2,1.22,22.56,,0,0.001,16.34,0.0595,0.008,0.0545,274.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-21",2,1.2,22.18,,0,0.001,16.064,0.059,0.007,0.053,270.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-23",3,1.22,21.82,,0,0.001,16.296,0.0593,0.006,0.1,273.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-24",6,4.35,152.63,,0,0.001,90.808,0.0593,0.021,0.0343,1528.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-26",4,2.68,55.6,,0,0.001,38.686,0.0593,0.008,0.0663,651.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-28",6,4.9,168.6,,0.001,0.001,100.24,0.0597,0.013,0.0417,1685.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-29",4,2.18,44.6,,0,0.001,30.848,0.0593,0.008,0.0873,518.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-09-30",8,6.18,132.32,,0,0.001,89.796,0.059,0.015,0.0589,1512.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-01",5,3.16,66.56,,0,0.001,45.86,0.0594,0.01,0.0846,771.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-02",6,4.22,89.27,,0,0.001,61.888,0.0595,0.013,0.0408,1040.969,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-03",4,2.23,45.52,,0,0.001,31.937,0.059,0.009,0.0653,537.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-04",6,3.74,136.81,,0,0.001,79.072,0.0592,0.02,0.0562,1331.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-05",5,3.74,83.72,,0,0.001,56.992,0.0598,0.01,0.0266,956.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-06",4,2.2,44.84,,0,0.001,31.068,0.059,0.008,0.0598,523.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-07",4,2.47,50.52,,0,0.001,34.613,0.0598,0.008,0.0505,581.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-12",4,2.22,44.66,,0,0.001,31.648,0.0595,0.009,0.079,532.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-13",4,2.51,51.52,,0,0.001,35.889,0.0593,0.011,0.0608,603.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-14",1,0.82,0,,0,0.001,3.854,0.059,0.007,0.202,65.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-18",12,10.76,228.18,,0.001,0.001,156.48,0.0595,0.019,0.0207,2630.873,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-19",7,4.18,111.55,,0,0.001,71.662,0.0591,0.015,0.0626,1207.133,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-20",4,2.2,42.84,,0,0.001,30.176,0.059,0.01,0.0883,508.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-21",4,2.39,50.99,,0,0.001,34.942,0.0595,0.008,0.048,586.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-02",4,2.26,46.34,,0,0.001,31.931,0.059,0.01,0.074,537.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-04",4,2.71,54.74,,0,0.001,38.178,0.0593,0.009,0.0585,641.547,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-05",7,5.39,116.49,,0,0.001,79.796,0.059,0.012,0.0264,1343.773,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-06",3,1.48,29.04,,0,0.001,20.328,0.0597,0.008,0.074,341.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-09",3,1.45,28.18,,0,0.001,19.692,0.0593,0.008,0.0997,331.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-10",3,1.69,33.44,,0,0.001,23.565,0.0597,0.008,0.075,396.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-12",2,1.33,53.61,,0,0.001,29.847,0.059,0.012,0.049,502.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-13",6,4.34,200.7,,0.001,0.001,109.56,0.0592,0.02,0.038,1843.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-15",4,2.95,111.66,,0,0.001,64.04,0.059,0.015,0.0578,1076.807,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-16",4,2.13,44,,0,0.001,30.326,0.0598,0.006,0.0998,510.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-01",7,3.89,79.5,,0,0.001,55.261,0.0591,0.02,0.084,930.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-02",3,2.21,60.64,,0,0.001,38.269,0.059,0.013,0.056,643.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-03",3,1.98,46.08,,0,0.001,30.718,0.0597,0.01,0.048,516.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-04",6,4.25,148.24,,0,0.001,87.379,0.0593,0.024,0.0412,1469.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-05",3,2.5,50.5,,0,0.001,35.816,0.059,0.011,0.044,603.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-10",3,2.2,45.37,,0,0.001,31.536,0.0593,0.01,0.044,530.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-11",4,3.47,97.88,,0,0.001,61.579,0.059,0.015,0.0373,1037.087,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-12",4,2.95,112.17,,0,0.001,64.869,0.0595,0.014,0.0365,1091.417,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-13",8,4.4,109.6,,0,0.001,71.32,0.0595,0.023,0.0919,1198.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-14",5,4,84.38,,0,0.001,58.404,0.0594,0.013,0.0386,982.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-15",5,3.95,83.33,,0,0.001,57.751,0.0594,0.015,0.0534,971.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-16",7,5.69,132.42,,0,0.001,87.694,0.0591,0.019,0.0364,1476.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Gilroy Energy Center, LLC",55810,"S-5",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-10",2,1.28,26.56,,0,0.001,19.16,0.06,0.061,0.573,321.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-15",3,2.2,45.23,,0,0.001,32.072,0.0593,0.059,0.3347,539.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-16",3,1.35,25.59,,0,0.001,18.998,0.059,0.051,1.0237,320.521,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-02",3,1.38,27.42,,0,0.001,19.572,0.0597,0.051,0.8737,329.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-10",1,0.13,0,,0,0.001,0.767,0.06,0.013,2.047,12.831,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-13",2,0.77,17.5,,0,0.001,12.188,0.059,0.066,0.7115,204.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-14",3,1.58,35.83,,0,0.001,24.411,0.0597,0.054,0.5317,410.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-15",9,7.45,160.09,,0.001,0.001,109.883,0.0593,0.06,0.2393,1849.741,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-26",2,1.25,29.56,,0,0.001,19.889,0.0595,0.058,0.4205,335.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-27",8,7.02,161.76,,0.001,0.001,109.836,0.0594,0.057,0.1245,1849.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-28",7,5.91,127.43,,0,0.001,87.605,0.0591,0.052,0.2454,1475.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-02-29",7,5.27,112.7,,0,0.001,77.945,0.0593,0.048,0.3651,1312.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-01",6,4.2,91.31,,0,0.001,62.647,0.0597,0.097,0.3532,1053.083,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-04",2,1.3,24.7,,0,0.001,18.417,0.059,0.055,0.4695,309.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-11",7,5.74,122.88,,0,0.001,85.426,0.0591,0.061,0.253,1438.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-12",18,15.89,386.65,,0.001,0.001,257.28,0.0592,0.111,0.1589,4331.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-13",9,6.66,143.44,,0.001,0.001,100.278,0.0593,0.084,0.2853,1686.486,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-14",6,4.68,167.4,,0.001,0.001,100.858,0.0593,0.111,0.2217,1696.737,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-15",7,6.12,132.48,,0,0.001,92.124,0.0594,0.018,0.1631,1549.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-16",8,6.35,136.51,,0,0.001,94.689,0.0591,0.061,0.3131,1595.513,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-17",1,0.12,1.56,,0,0.001,1.416,0.06,0.019,1.559,23.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-18",5,2.44,48.48,,0,0.001,34.676,0.0594,0.083,0.7386,583.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-24",14,12.29,556.07,,0.002,0.001,312.757,0.0595,0.109,0.1761,5259.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-25",12,10.44,474.64,,0.001,0.001,265.552,0.0592,0.104,0.1712,4467.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-26",14,12.24,556.16,,0.002,0.001,312.324,0.0592,0.121,0.2129,5254.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-03-31",7,5.77,248.52,,0.001,0.001,141.133,0.0593,0.071,0.1314,2375.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-01",9,7.4,159.08,,0.001,0.001,110.044,0.0593,0.062,0.3144,1852.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-08",3,1.49,29.72,,0,0.001,21.586,0.0597,0.053,0.7057,362.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-28",3,1.32,26.06,,0,0.001,19.864,0.059,0.044,0.9117,334.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-01",5,4.24,114.93,,0,0.001,78.487,0.0594,0.061,0.2292,1319.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-02",10,7.94,222.71,,0.001,0.001,148.515,0.0591,0.121,0.3648,2501.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-06",5,2.54,63.1,,0,0.001,44.72,0.0592,0.099,0.7286,752.421,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-08",3,1.59,49.29,,0,0.001,32.003,0.0593,0.049,0.485,539.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-09",3,2.09,59.2,,0,0.001,39.972,0.059,0.057,0.234,672.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-11",4,1.78,41.07,,0,0.001,29.75,0.0593,0.112,0.9583,500.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-13",2,1.27,28.01,,0,0.001,20.689,0.059,0.064,0.5175,348.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-16",3,1.36,31.2,,0,0.001,22.576,0.059,0.047,1.0097,380.636,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-19",3,1.35,25.78,,0,0.001,20.301,0.0597,0.061,1.1693,341.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-21",5,3.59,89.75,,0,0.001,63.516,0.0596,0.089,0.2432,1068.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-25",7,6.95,245,,0.001,0.001,154.69,0.0591,0.066,0.0493,2603.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-26",12,10.14,460.6,,0.001,0.0009,276.464,0.0593,0.103,0.1118,4652.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-27",13,11.93,540.66,,0.002,0.001,321.484,0.0594,1.462,0.5521,5409.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-28",17,16.1,748.2,,0.002,0.001,443.81,0.0592,2.71,0.8926,7469.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-29",5,3.77,116.59,,0,0.001,76.305,0.0594,1.004,1.7132,1283.371,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-03",9,7.44,220.68,,0.001,0.001,147.2,0.0593,0.828,1.1949,2475.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-04",6,5.09,162.5,,0.001,0.001,105.887,0.0595,0.902,1.5133,1782.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-08",2,1.48,28.9,,0,0.001,22.224,0.0595,0.467,2.421,373.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-09",3,2.25,80.44,,0,0.001,50.116,0.0597,0.057,0.3133,842.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-10",9,7.54,248.54,,0.001,0.001,159.674,0.0592,0.068,0.1914,2686.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-11",6,4.29,116.64,,0,0.001,81.747,0.0592,0.065,0.5178,1376.273,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-15",5,3.25,71.89,,0,0.001,52.35,0.0594,0.057,0.6964,879.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-19",6,4.79,136.24,,0,0.001,93.55,0.059,0.069,0.277,1575.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-20",4,2.79,68.88,,0,0.001,49.749,0.0593,0.052,0.3975,836.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-21",5,3.57,150.18,,0,0.001,92.945,0.0596,0.067,0.3714,1561.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-22",7,6.85,284.07,,0.001,0.001,176.866,0.0593,0.116,0.0789,2976.933,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-23",8,6.6,287.5,,0.001,0.001,176.05,0.059,0.116,0.2448,2964.707,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-24",24,22.46,659.23,,0.002,0.001,438.005,0.0592,0.092,0.0933,7372.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-25",9,8.67,333.01,,0.001,0.001,205.695,0.0591,0.076,0.0664,3462.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-26",9,8.05,356.12,,0.001,0.001,213.948,0.0592,0.089,0.1002,3598.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-27",8,5.06,148.4,,0,0.001,98.702,0.0594,0.1,0.5863,1660.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-29",5,4.6,106.36,,0,0.001,76.102,0.0594,0.059,0.102,1279.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-06-30",3,1.63,32.92,,0,0.001,25.323,0.0597,0.054,0.4797,425.553,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-02",7,5.52,118.4,,0,0.001,87.464,0.0596,0.093,0.2624,1469.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-03",3,1.79,35.9,,0,0.001,27.074,0.0593,0.055,0.361,455.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-04",8,4.58,127.46,,0,0.001,86.198,0.0591,0.164,0.4914,1450.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-05",4,3.39,92.31,,0,0.001,62.99,0.059,0.081,0.1643,1060.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-08",5,3.05,84.06,,0,0.001,58.176,0.059,0.136,0.5598,979.447,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-09",24,22.37,678.44,,0.002,0.001,452.578,0.0594,0.13,0.1419,7614.161,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-10",16,14.73,537.64,,0.002,0.001,337.148,0.0593,0.086,0.1458,5673.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-11",18,17.35,549.46,,0.002,0.001,356.83,0.0593,0.092,0.0448,6002.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-12",23,20.86,651.53,,0.002,0.001,422.932,0.0595,0.099,0.1104,7112.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-13",10,8.22,214.89,,0.001,0.001,147.732,0.0591,0.108,0.2844,2487.921,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-14",5,2.71,44.48,,0,0.001,36.949,0.0596,0.088,1.1322,620.743,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-15",7,5.48,243.84,,0.001,0.001,144.401,0.059,0.108,0.4717,2429.141,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-16",11,9.47,368.59,,0.001,0.001,231.315,0.0591,0.088,0.2112,3894.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-17",5,2.45,48.81,,0,0.001,37.873,0.0592,0.057,0.7494,636.743,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-18",6,5.07,186.49,,0.001,0.001,117.211,0.0598,0.12,0.259,1970.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-19",17,15.81,485.75,,0.002,0.001,316.63,0.0592,0.112,0.1248,5330.037,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-20",9,7.51,248.05,,0.001,0.001,157.845,0.0593,0.118,0.2659,2655.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-21",4,1.95,38.02,,0,0.001,28.79,0.059,0.064,0.684,485.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-22",3,1.3,27.36,,0,0.001,19.878,0.06,0.053,0.9287,333.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-24",9,7.54,312,,0.001,0.001,185.15,0.0591,0.069,0.2147,3114.446,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-25",11,10.18,365.88,,0.001,0.001,224.258,0.0592,0.062,0.1583,3773.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-26",11,9.41,266.91,,0.001,0.001,176.134,0.0594,0.083,0.1078,2962.431,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-27",9,7.4,294.41,,0.001,0.001,177.201,0.0591,0.141,0.1874,2982.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-28",11,9.32,346.52,,0.001,0.001,211.767,0.0592,0.147,0.1411,3564.238,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-29",6,5.17,205.4,,0.001,0.001,123.816,0.0593,0.066,0.2087,2083.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-30",6,5.35,223.15,,0.001,0.001,132.755,0.059,0.067,0.128,2235.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-07-31",8,6.42,218.38,,0.001,0.001,137.13,0.0593,0.057,0.267,2306.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-07",5,2.24,2.24,,0,0.001,15.41,0.0594,0.093,1.055,258.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-08",8,6.4,162.08,,0.001,0.001,109.684,0.0593,0.057,0.3484,1845.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-09",9,8.37,245.88,,0.001,0.001,159.768,0.0593,0.059,0.1009,2688.079,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-10",7,5.56,174.06,,0.001,0.001,111.036,0.0593,0.078,0.3053,1869.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-12",5,4.25,110.62,,0,0.001,74.612,0.0596,0.062,0.2148,1254.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-13",9,7.64,304.84,,0.001,0.001,182.436,0.0593,0.108,0.2172,3069.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-14",10,8.65,332.95,,0.001,0.001,198.64,0.0595,0.073,0.1458,3341.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-15",13,12.37,579.36,,0.002,0.001,333.145,0.0595,0.082,0.0735,5600.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-16",18,14.15,472.37,,0.001,0.001,293.968,0.0592,0.167,0.4453,4948.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-17",11,8.08,260.24,,0.001,0.001,170.9,0.0591,0.077,0.1226,2876.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-18",12,10.85,474.4,,0.001,0.001,277.971,0.0592,0.129,0.1267,4676.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-19",12,10.85,386.53,,0.001,0.001,235.635,0.0592,0.1,0.1399,3968.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-20",6,4.3,90.96,,0,0.001,65.478,0.0592,0.052,0.5442,1102.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-22",8,7.05,279.54,,0.001,0.001,166.69,0.0593,0.072,0.1203,2805.299,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-23",6,4.84,154.93,,0,0.001,98.45,0.0593,0.059,0.2055,1655.767,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-24",10,8.4,201.24,,0.001,0.001,139.208,0.0593,0.059,0.2142,2342.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-25",8,5.17,165.73,,0.001,0.001,104.921,0.0591,0.113,0.4564,1766.727,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-26",6,4.83,157.85,,0.001,0.001,99.184,0.0595,0.059,0.166,1669.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-27",7,5.3,191.06,,0.001,0.001,116.544,0.0594,0.07,0.4076,1959.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-28",4,2.99,99.32,,0,0.001,62.208,0.0595,0.063,0.3733,1047.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-29",5,4.49,151.51,,0,0.001,94.571,0.0594,0.063,0.1296,1591.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-30",4,3.07,64.16,,0,0.001,46.385,0.06,0.054,0.2193,778.479,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-08-31",8,7.04,226.8,,0.001,0.001,142.508,0.0593,0.062,0.1935,2398.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-03",2,1.62,29.28,,0,0.001,22.815,0.059,0.053,0.293,383.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-04",2,1.72,58.38,,0,0.001,37.365,0.059,0.075,0.2515,628.849,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-05",9,7.65,274.04,,0.001,0.001,171.067,0.0592,0.064,0.1507,2879.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-06",8,6.23,237.1,,0.001,0.001,143.472,0.0595,0.057,0.3976,2414.067,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-07",11,10.12,382.32,,0.001,0.001,232.632,0.0593,0.071,0.1726,3912.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-08",2,1.08,21,,0,0.001,16.004,0.06,0.009,0.877,268.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-13",10,8.4,179.75,,0.001,0.001,131.355,0.0593,0.133,0.3146,2211.603,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-14",7,6.37,274.18,,0.001,0.001,167.894,0.0593,0.088,0.0864,2825.387,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-15",8,6.83,287.54,,0.001,0.001,176.578,0.0593,0.071,0.1964,2969.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-16",7,6.01,208.55,,0.001,0.001,132.08,0.0591,0.081,0.3171,2223.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-17",9,7.25,280.38,,0.001,0.001,173.086,0.0594,0.067,0.3399,2911.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-18",4,2.87,66.92,,0,0.001,48.295,0.059,0.053,0.23,813.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-19",4,3.04,68.32,,0,0.001,49.353,0.059,0.056,0.198,830.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-21",3,2.4,70.55,,0,0.001,46.815,0.0593,0.054,0.2253,786.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-22",6,4.68,108.12,,0,0.001,76.878,0.0592,0.054,0.3468,1293.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-23",8,7.52,205.04,,0.001,0.001,138.82,0.0596,0.055,0.0746,2334.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-24",1,0.1,0.1,,0,0.001,0.71,0.059,0.008,1.407,12.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-27",4,2.54,83.78,,0,0.001,53.502,0.0593,0.071,0.5228,900.354,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-28",8,6.82,185.68,,0.001,0.001,125.28,0.0593,0.082,0.2175,2107.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-29",7,5.8,199.68,,0.001,0.001,126.314,0.0593,0.077,0.2806,2124.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-09-30",5,4.01,102.24,,0,0.001,70.97,0.0592,0.059,0.1562,1195.851,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-01",4,2.33,54.25,,0,0.001,38.578,0.0595,0.049,0.708,650.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-02",2,1.55,48.38,,0,0.001,31.298,0.0595,0.065,0.2685,526.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-03",2,1.3,36.9,,0,0.001,25.82,0.0595,0.076,0.427,433.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-04",2,1.55,48.85,,0,0.001,32.019,0.0595,0.079,0.2625,538.141,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-05",5,4.15,177.39,,0.001,0.001,107.109,0.059,0.074,0.127,1801.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-06",2,1.4,45.96,,0,0.001,29.436,0.059,0.076,0.326,496.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-10",3,1.41,34.6,,0,0.001,24.244,0.059,0.055,0.858,407.891,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-17",4,1.96,72.76,,0,0.001,44.241,0.059,0.148,0.875,744.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-18",3,1.7,33.5,,0,0.001,24.87,0.0593,0.049,0.668,418.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-19",4,2.82,96.37,,0,0.001,60.251,0.0593,0.071,0.2375,1014.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-20",2,1.32,25.08,,0,0.001,19.187,0.059,0.059,0.4495,323.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-21",3,2.07,46,,0,0.001,32.741,0.059,0.061,0.282,551.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-25",12,11.65,320,,0.001,0.001,211.155,0.0592,0.073,0.064,3556.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-26",21,20.12,509.48,,0.002,0.001,347.436,0.0592,0.089,0.0815,5848.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-27",3,2.08,83.44,,0,0.001,50.049,0.0593,0.074,0.314,842.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-02",3,1.98,42.28,,0,0.001,30.748,0.0597,0.058,0.4027,517.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-03",2,1.33,33.81,,0,0.001,23.366,0.059,0.065,0.344,392.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-04",5,3.89,87.54,,0,0.001,62.72,0.0594,0.06,0.19,1055.433,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-05",6,4.59,103.23,,0,0.001,73.108,0.0593,0.065,0.3267,1229.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-06",3,1.88,35.36,,0,0.001,26.876,0.0593,0.075,0.7003,451.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-09",3,2.07,41.73,,0,0.001,31.449,0.0593,0.065,0.3527,529.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-10",3,2.08,42.44,,0,0.001,31.594,0.0593,0.056,0.2887,531.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-11",3,1.92,38.5,,0,0.001,28.924,0.0593,0.056,0.6217,486.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-14",2,1.39,25.89,,0,0.001,20.486,0.059,0.066,0.4555,345.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-15",17,16.32,415.8,,0.001,0.001,290.188,0.0595,0.078,0.0913,4881.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-16",12,9.98,210.96,,0.001,0.001,156.7,0.0593,0.073,0.2777,2635.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-21",3,1.38,27.57,,0,0.001,20.658,0.0597,0.054,0.7657,347.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-22",3,1.55,30.53,,0,0.001,23.021,0.0593,0.054,0.6467,387.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-27",11,9.4,203.08,,0.001,0.001,148.248,0.0591,0.069,0.2473,2496.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-29",3,1.3,25.7,,0,0.001,19.47,0.0593,0.053,0.8503,327.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-11-30",2,1.55,49.03,,0,0.001,31.877,0.059,0.147,0.4425,537.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-01",5,2.69,54.79,,0,0.001,41.529,0.0592,0.116,0.6538,700.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-02",23,22.25,488.75,,0.002,0.001,352.05,0.0593,0.078,0.0751,5927.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-03",16,15.33,337.92,,0.001,0.001,245.442,0.0596,0.104,0.103,4125.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-04",8,7.35,185.2,,0.001,0.001,128.545,0.0594,0.025,0.0375,2160.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-05",2,1.39,27.45,,0,0.001,20.936,0.0595,0.057,0.386,351.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-06",2,1.5,27.72,,0,0.001,21.822,0.06,0.058,0.312,366.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-07",3,1.52,27.98,,0,0.001,21.86,0.0597,0.054,0.7937,367.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-08",2,1.39,26.56,,0,0.001,20.709,0.0595,0.061,0.332,348.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-09",3,2.58,53.52,,0,0.001,39.634,0.059,0.057,0.1937,668.159,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-10",4,2.53,78,,0,0.001,50.778,0.0593,0.055,0.533,854.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-11",2,1.65,42.8,,0,0.001,29.49,0.0595,0.069,0.274,495.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-12",3,2.63,69.45,,0,0.001,47.157,0.059,0.066,0.186,794.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-14",6,4.82,113.67,,0,0.001,80.837,0.0593,0.132,0.2322,1360.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-15",2,0.94,17.48,,0,0.0005,13.664,0.0595,0.06,0.309,229.678,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-16",9,7.05,283.37,,0.001,0.001,173.713,0.0592,0.153,0.1809,2921.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-22",5,3.72,78.6,,0,0.001,58.126,0.0594,0.09,0.4798,977.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-27",2,1.4,28,,0,0.001,20.96,0.0595,0.058,0.4205,352.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-28",2,1.3,24.8,,0,0.001,19.22,0.059,0.061,0.3565,323.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Feather River Energy Center",55847,"UNIT1",,"2020-12-31",11,9.49,221.39,,0.001,0.001,158.598,0.0594,0.07,0.2026,2667.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Inland Empire Energy Center",55853,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-16",3,1.35,28.13,,0,0.001,21.513,0.0597,0.005,0.0893,361.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-02",3,1.38,19.94,,0,0.001,18.444,0.06,0.008,0.1527,309.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-03",1,0.1,0,,0,0.001,0.66,0.06,0.002,0.286,11.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-07",1,0.23,1.84,,0,0.001,2.323,0.059,0.003,0.176,39.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-26",2,1.24,26.89,,0,0.001,20.489,0.06,0.007,0.0535,344.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-27",3,1.45,50.2,,0,0.001,32.471,0.059,0.008,0.0847,547.231,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-02",3,1.8,38.06,,0,0.001,28.726,0.0593,0.01,0.1097,483.739,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-12",10,8.32,189.92,,0.001,0.001,139.9,0.0595,0.011,0.027,2352.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-13",4,2.3,47.54,,0,0.001,36.146,0.0593,0.005,0.0565,607.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-14",3,2.29,47.24,,0,0.001,36.728,0.059,0.007,0.0257,618.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-16",8,6.35,130.51,,0.001,0.001,100.656,0.0593,0.01,0.0344,1694.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-13",3,1.9,34.52,,0,0.001,28.206,0.059,0.015,0.0763,474.562,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-18",16,14.75,458.85,,0.002,0.001,303.425,0.0594,0.021,0.0169,5105.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-26",7,6.42,256.66,,0.001,0.001,159.812,0.0593,0.013,0.011,2689.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-27",9,7.78,312.7,,0.001,0.001,193.394,0.059,0.015,0.025,3256.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-02",1,0.25,3,,0,0.001,3.025,0.06,0.004,0.148,50.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-03",9,7.44,160.24,,0.001,0.001,119.92,0.0592,0.008,0.0258,2018.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-04",6,4.4,93.52,,0,0.001,70.388,0.0593,0.006,0.0373,1184.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-09",3,2.25,81.28,,0,0.001,51.913,0.0593,0.008,0.0337,873.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-10",7,5.29,146.49,,0.001,0.001,101.065,0.0594,0.008,0.0359,1698.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-11",6,4.29,90.28,,0,0.001,69.225,0.059,0.007,0.0603,1165.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-15",5,3.25,68.97,,0,0.001,52.366,0.0594,0.006,0.0574,880.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-26",3,1.54,35.4,,0,0.0007,25.898,0.0593,0.005,0.095,436.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-01",6,5.54,163.32,,0.001,0.001,109.479,0.0592,0.01,0.0183,1840.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-10",2,1.23,42.2,,0,0.001,26.651,0.059,0.006,0.0475,449.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-11",3,2.52,98.24,,0,0.001,59.999,0.059,0.01,0.0233,1010.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-12",2,1.52,61.45,,0,0.001,37.456,0.059,0.008,0.028,630.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-26",2,1.23,23.34,,0,0.001,18.498,0.0595,0.006,0.0405,311.469,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-29",6,4.62,99.67,,0,0.001,74.594,0.059,0.008,0.0257,1255.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-30",6,4.58,147.74,,0,0.001,95.653,0.059,0.01,0.0243,1609.993,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-07-31",4,2.22,47.68,,0,0.001,35.682,0.0598,0.007,0.0895,600,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-01",3,1.33,26.44,,0,0.001,20.571,0.0593,0.006,0.0923,345.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-03",3,1.3,25.36,,0,0.001,19.914,0.0593,0.006,0.1047,334.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-12",3,1.8,39.96,,0,0.001,30.134,0.0593,0.008,0.0423,507.619,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-13",7,5.72,195.88,,0.001,0.001,126.332,0.0593,0.013,0.0331,2124.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-14",9,7.42,197.5,,0.001,0.001,136.12,0.0591,0.011,0.0357,2291.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-15",8,6.9,306.8,,0.001,0.001,183.32,0.0596,0.018,0.0206,3082.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-16",6,5.13,133.8,,0,0.001,93.117,0.0593,0.01,0.0228,1566.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-17",11,9.85,387.47,,0.001,0.001,238.305,0.0594,0.017,0.0191,4008.905,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-18",14,13.12,601.95,,0.002,0.001,356.94,0.0591,0.029,0.0119,6009.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-19",3,1.89,49.23,,0,0.001,34.691,0.0593,0.006,0.0497,583.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-20",5,2.73,55,,0,0.001,42.163,0.0592,0.008,0.1144,710.831,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-21",6,5.03,107.32,,0,0.001,80.85,0.0592,0.009,0.0308,1361.551,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-24",4,3.32,69.78,,0,0.001,53.098,0.0593,0.01,0.0268,893.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-28",3,1.47,48.48,,0,0.001,31.837,0.06,0.008,0.0867,534.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-04",2,1.45,28.71,,0,0.001,22.504,0.059,0.007,0.034,379.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-05",8,6.35,155.59,,0.001,0.001,111.916,0.0591,0.01,0.0468,1883.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-06",9,7.21,222.86,,0.001,0.001,147.945,0.0592,0.013,0.0574,2490.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-07",6,4.18,144.8,,0,0.001,93.42,0.0592,0.013,0.0718,1571.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-17",2,1.6,32,,0,0.001,24.942,0.06,0.005,0.025,418.817,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-18",3,1.52,34.08,,0,0.001,25.752,0.0597,0.005,0.055,432.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-19",4,3.02,67.47,,0,0.001,50.119,0.0595,0.006,0.0185,842.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-28",4,3.02,89.14,,0,0.001,59.943,0.0593,0.011,0.0288,1008.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-29",3,1.77,55.93,,0,0.001,36.676,0.059,0.006,0.0547,617.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-09-30",5,3.5,91.66,,0,0.001,64.365,0.0594,0.006,0.0322,1084.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-01",3,2.12,43.35,,0,0.001,33.296,0.059,0.005,0.024,561.183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-02",2,1.53,40.61,,0,0.001,28.414,0.059,0.006,0.0255,478.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-03",2,1.28,35.42,,0,0.001,24.452,0.0595,0.007,0.038,410.993,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-04",2,1.26,34.82,,0,0.001,23.99,0.059,0.007,0.03,404.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-05",4,3.35,107.94,,0,0.001,70.236,0.059,0.009,0.0168,1182.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-06",2,1.32,30.68,,0,0.001,22.46,0.0595,0.007,0.0335,377.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-10",2,1.43,29.43,,0,0.001,22.271,0.059,0.005,0.026,375.189,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-12",3,1.38,27.14,,0,0.001,20.806,0.0597,0.004,0.074,349.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-13",4,2.28,47,,0,0.001,35.628,0.0593,0.005,0.077,598.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-14",5,3.86,134.02,,0,0.001,85.09,0.0592,0.009,0.028,1433.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-15",4,3.4,81.4,,0,0.001,58.74,0.0593,0.007,0.0175,988.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-16",2,1.34,25.56,,0,0.001,20.284,0.0595,0.006,0.0335,341.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-18",2,1.18,22.4,,0,0.001,17.926,0.0595,0.005,0.034,301.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-19",3,2.3,57.68,,0,0.001,40.943,0.0597,0.006,0.02,688.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-20",2,1.3,25.55,,0,0.001,19.85,0.0595,0.005,0.036,333.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-21",2,1.25,24.45,,0,0.001,19.03,0.06,0.005,0.029,319.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-27",2,1.33,38.57,,0,0.001,25.941,0.059,0.013,0.058,436.537,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-02",2,1.27,24.13,,0,0.001,19.217,0.059,0.006,0.05,323.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-03",2,1.25,26.76,,0,0.001,20.116,0.06,0.006,0.0535,337.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-04",4,2.18,56.53,,0,0.001,39.924,0.0595,0.013,0.0408,671.069,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-05",6,4.57,100.05,,0,0.001,74.467,0.0597,0.008,0.0337,1251.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-06",3,1.89,33.8,,0,0.001,27.646,0.0597,0.009,0.0713,465.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-09",3,2.07,40.73,,0,0.001,32.192,0.0593,0.008,0.0397,541.353,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-10",3,2.35,46.65,,0,0.001,36.6,0.0593,0.007,0.0313,616.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-11",4,3.17,62.83,,0,0.001,49.365,0.0593,0.008,0.0238,831.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-15",2,0.1,0,,0,0.001,0.67,0.0595,0.001,0.254,11.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-21",3,0.88,7.36,,0,0.001,9.026,0.0593,0.008,0.121,152.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-22",5,2.65,61.57,,0,0.001,44.757,0.0594,0.011,0.0482,752.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-29",3,1.33,52.1,,0,0.001,32.603,0.059,0.006,0.0497,549.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-11-30",3,1.27,25.92,,0,0.001,20.203,0.059,0.005,0.0917,340.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-01",5,2.63,61.01,,0,0.001,45.027,0.0592,0.027,0.1038,757.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-02",3,2.12,64.64,,0,0.001,43.244,0.0593,0.008,0.029,728.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-03",6,4.51,128.76,,0,0.001,88.262,0.0593,0.014,0.0227,1485.257,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-04",8,5.52,198.68,,0.001,0.001,126.576,0.0595,0.016,0.0384,2127.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-05",3,2.12,42.2,,0,0.001,33.4,0.0593,0.006,0.0277,561.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-06",2,1.23,24.89,,0,0.001,19.485,0.0595,0.006,0.0465,328.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-07",3,1.55,33.1,,0,0.001,25.065,0.0593,0.006,0.0867,422.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-08",2,1.37,26.8,,0,0.001,21.166,0.0595,0.007,0.0355,356.379,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-09",3,2.08,40.95,,0,0.001,32.405,0.059,0.006,0.0287,544.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-10",4,2.53,73.55,,0,0.001,50.419,0.0595,0.007,0.0623,847.177,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-11",4,3.15,121.45,,0,0.001,76.72,0.0593,0.009,0.0193,1290.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-12",3,2.63,113.27,,0,0.001,69.349,0.059,0.01,0.0183,1167.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-13",14,11.5,300.1,,0.001,0.001,213.61,0.0594,0.016,0.0379,3593.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-14",5,3.95,80.25,,0,0.001,62.9,0.0594,0.007,0.02,1057.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-15",8,6.54,169.38,,0.001,0.001,120.901,0.0594,0.02,0.0244,2033.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-16",8,6.03,227.35,,0.001,0.001,143.62,0.0591,0.017,0.0208,2417.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-20",2,1.38,27.6,,0,0.001,21.948,0.0595,0.006,0.038,368.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-27",2,1.4,28.1,,0,0.001,22.31,0.059,0.006,0.036,375.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-28",2,1.28,26.76,,0,0.001,20.734,0.059,0.006,0.031,349.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Wolfskill Energy Center",55855,"UNIT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-01",24,24,2671,,0.006,0.001,1273,0.059,0.074,0.0069,21421,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-02",24,24,2719,,0.007,0.001,1297.6,0.059,0.075,0.0068,21834,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-03",24,24,2683,,0.006,0.001,1273.4,0.059,0.075,0.007,21426.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-04",24,24,2761,,0.007,0.001,1309.4,0.059,0.076,0.0069,22031.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-05",24,24,2751,,0.007,0.001,1307.9,0.059,0.071,0.0064,22010.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-06",24,24,2671,,0.006,0.001,1269.4,0.059,0.069,0.0065,21365.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-07",24,24,2563,,0.006,0.001,1232.2,0.059,0.071,0.0068,20734.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-08",24,24,2648,,0.006,0.001,1267,0.059,0.075,0.007,21315.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-09",24,24,2666,,0.006,0.001,1271.5,0.059,0.075,0.007,21398.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-10",24,23.72,2823.68,,0.007,0.001,1334.84,0.059,0.079,0.007,22457.192,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-11",22,21.4,2355.4,,0.006,0.001,1134.26,0.059,0.066,0.0078,19082.24,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-12",24,24,2741,,0.007,0.001,1296,0.059,0.069,0.0063,21805.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-13",24,24,2695,,0.006,0.001,1276,0.059,0.072,0.0067,21470.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-14",24,24,2754,,0.007,0.001,1303.3,0.059,0.076,0.0069,21933,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-15",24,24,2859,,0.007,0.001,1339.1,0.059,0.078,0.007,22532.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-16",24,24,2761,,0.006,0.001,1278.7,0.059,0.075,0.007,21509.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-17",24,24,2821,,0.007,0.001,1325.2,0.059,0.082,0.0074,22298.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-18",24,24,2740,,0.007,0.001,1303.8,0.059,0.08,0.0073,21939.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-19",24,24,2783,,0.007,0.001,1319.2,0.059,0.079,0.0071,22199,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-20",24,24,2837,,0.007,0.001,1328.2,0.059,0.078,0.007,22348.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-21",24,24,2719,,0.007,0.001,1294.5,0.059,0.076,0.007,21782.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-22",24,24,2664,,0.006,0.001,1271.1,0.059,0.074,0.0069,21392.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-23",24,24,2658,,0.006,0.001,1267.8,0.059,0.074,0.007,21330.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-24",20,19.53,2079.76,,0.005,0.001,999.731,0.059,0.059,0.0071,16822.064,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-15",1,0.28,1.96,,0,0.001,2.548,0.06,0.001,0.059,42.756,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-16",15,14.43,1636.61,,0.004,0.001,770.745,0.059,0.053,0.0123,12970.303,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-17",20,18.58,2167.38,,0.005,0.001,1005.774,0.0591,0.082,0.0136,16921.094,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-18",19,16.87,1868.2,,0.004,0.001,863.594,0.0591,0.083,0.0169,14530.617,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-26",16,14.38,1433.24,,0.004,0.001,702.718,0.0591,0.085,0.0186,11824.39,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-08",8,7.83,814.19,,0.002,0.001,404.853,0.059,0.078,0.0341,6811.596,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-22",10,8.95,833.2,,0.002,0.001,447.955,0.0591,0.04,0.0155,7538.71,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-25",13,12.33,1426.95,,0.003,0.001,678.497,0.0591,0.087,0.0287,11420.096,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-26",18,16.43,2130.67,,0.005,0.001,1008.462,0.0591,0.074,0.0092,16970.866,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-27",24,24,2919,,0.007,0.001,1362.2,0.059,0.074,0.0065,22918.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-28",24,24,2784,,0.007,0.001,1288.5,0.059,0.073,0.0068,21681.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-29",24,24,3052,,0.007,0.001,1408.2,0.059,0.081,0.0068,23694.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-30",24,24,3040,,0.007,0.001,1390.1,0.059,0.079,0.0068,23390.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-05-31",1,0.35,26.6,,0,0.001,11.725,0.059,0.001,0.013,197.435,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-01",10,8.63,941.61,,0.002,0.001,440.315,0.0591,0.068,0.0327,7411.24,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-02",14,13.42,1568.92,,0.004,0.001,733.394,0.059,0.083,0.0221,12341.928,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-03",24,24,2992,,0.007,0.001,1388.1,0.059,0.077,0.0065,23361.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-04",18,16.2,1870.28,,0.004,0.001,869.505,0.059,0.08,0.0148,14628.757,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-09",11,9.95,1154.52,,0.003,0.001,539.236,0.059,0.084,0.0298,9076.92,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-10",15,14.75,1772,,0.004,0.001,834.725,0.0591,0.074,0.0153,14043.825,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-11",19,16.49,1889.6,,0.004,0.001,885.146,0.0592,0.102,0.0185,14891.481,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-18",10,8.77,968.08,,0.002,0.001,459.161,0.059,0.064,0.0277,7724.943,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-22",12,10.92,1208.18,,0.003,0.001,570.016,0.0591,0.058,0.0181,9590.21,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-23",10,8.78,970.6,,0.002,0.001,470.628,0.059,0.059,0.0185,7922.398,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-24",12,10.71,1248.42,,0.003,0.001,580.927,0.059,0.057,0.0134,9776.092,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-25",11,9.83,1099.47,,0.003,0.001,513.984,0.0591,0.055,0.0177,8647.369,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-26",12,10.46,1213.87,,0.003,0.001,565.558,0.059,0.058,0.0147,9513.517,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-09",12,11.38,1301.64,,0.003,0.001,610.298,0.0591,0.057,0.0202,10266.832,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-10",19,17.38,1995.41,,0.005,0.001,944.563,0.0591,0.119,0.0208,15894.795,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-11",19,17.43,1960.5,,0.005,0.001,924.754,0.0591,0.125,0.0225,15560.408,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-12",19,17.36,2006.08,,0.005,0.001,952.627,0.0591,0.121,0.0208,16034.284,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-13",13,11.7,1307.37,,0.003,0.001,610.298,0.059,0.073,0.022,10270.942,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-14",16,14.45,1684.65,,0.004,0.001,777.39,0.0591,0.069,0.0123,13081.07,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-15",15,13.36,1550.47,,0.004,0.001,718.994,0.0591,0.06,0.0115,12099.916,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-16",1,0.33,26.07,,0,0.001,11.187,0.06,0.001,0.014,188.001,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-19",14,12.5,1301.3,,0.003,0.001,619.31,0.0592,0.081,0.0231,10416.835,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-20",14,13.27,1526.43,,0.004,0.001,715.747,0.059,0.074,0.0176,12043.859,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-21",18,16.63,1836.54,,0.004,0.001,847.533,0.059,0.094,0.0175,14259.544,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-27",11,10.4,1166.2,,0.003,0.001,555.06,0.059,0.07,0.0285,9340.14,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-28",19,17.43,1950.3,,0.005,0.001,927.522,0.0591,0.114,0.0199,15608.54,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-29",11,9.27,904.61,,0.002,0.001,442.879,0.0591,0.089,0.0286,7448.968,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-30",11,9.17,848.35,,0.002,0.001,418.284,0.0592,0.081,0.0292,7038.789,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-01",8,6.38,564.6,,0.001,0.001,279.084,0.059,0.086,0.0429,4697.852,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-02",15,14.88,1406.64,,0.003,0.001,679.568,0.0591,0.104,0.0254,11431.632,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-03",2,1.3,122.5,,0,0.001,56.98,0.059,0.004,0.012,958.24,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-04",20,18.53,2233.67,,0.005,0.001,1062.269,0.059,0.096,0.0165,17875.156,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-05",20,19.13,2253,,0.005,0.001,1038.479,0.059,0.078,0.0106,17472.561,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-06",15,14.53,1782.63,,0.004,0.001,812.393,0.059,0.042,0.0063,13670.112,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-10",15,14.5,1518,,0.004,0.001,719.6,0.059,0.075,0.0203,12109.85,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-11",19,17.49,1887.42,,0.004,0.001,890.045,0.0591,0.096,0.0163,14974.954,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-12",14,12.7,1394.08,,0.003,0.001,673.364,0.059,0.073,0.0212,11328.728,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-13",24,24,2962,,0.007,0.001,1372.2,0.059,0.065,0.0057,23092.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-14",24,24,3149,,0.007,0.001,1470.2,0.059,0.07,0.0057,24741.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-15",24,24,3211,,0.008,0.001,1504.2,0.059,0.074,0.0058,25306.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-16",24,24,3179,,0.008,0.001,1498,0.059,0.071,0.0056,25203.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-17",24,24,3137,,0.007,0.001,1470.2,0.059,0.069,0.0055,24745.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-18",24,24,3075,,0.007,0.001,1438.6,0.059,0.067,0.0055,24207.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-19",24,24,3137,,0.007,0.001,1471,0.059,0.071,0.0058,24751.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-20",24,24,3040,,0.007,0.001,1405.7,0.059,0.067,0.0056,23650.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-21",24,24,3041,,0.007,0.001,1391.5,0.059,0.07,0.006,23415.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-22",19,17.37,1987.4,,0.005,0.001,936.417,0.059,0.093,0.0154,15754.027,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-23",20,18.49,2207.23,,0.005,0.001,1026.027,0.0591,0.069,0.0092,17265.376,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-24",19,17.69,2090.62,,0.005,0.001,976.878,0.059,0.086,0.0134,16436.351,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-25",19,17.4,2004,,0.005,0.001,939.375,0.059,0.092,0.0148,15805.33,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-26",24,24,2789,,0.007,0.001,1290.7,0.059,0.054,0.005,21718.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-27",24,24,2780,,0.007,0.001,1289,0.059,0.054,0.005,21688.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-28",24,24,2786,,0.007,0.001,1298.9,0.059,0.055,0.005,21855.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-29",24,23.45,2769.7,,0.007,0.001,1289.335,0.059,0.082,0.009,21696.035,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-30",24,24,2998,,0.007,0.001,1397.7,0.059,0.067,0.0057,23522.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-08-31",19,18.52,2311.36,,0.005,0.001,1083.092,0.059,0.05,0.0057,18224.696,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-03",22,21.03,2322.09,,0.006,0.001,1104.999,0.059,0.111,0.0156,18594.062,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-04",24,24,3071,,0.007,0.001,1430,0.059,0.068,0.0057,24063.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-05",24,24,3064,,0.007,0.001,1426.2,0.059,0.07,0.0058,23997.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-06",24,24,3132,,0.007,0.001,1477,0.059,0.068,0.0055,24854,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-07",20,18.37,2207.5,,0.005,0.001,1055.871,0.059,0.072,0.0119,17768.842,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-08",24,24,3089,,0.007,0.001,1440.2,0.059,0.065,0.0054,24231.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-09",24,23.35,2826,,0.007,0.001,1310.78,0.059,0.06,0.0058,22055.88,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-10",9,8.25,810.55,,0.002,0.001,401.35,0.059,0.064,0.0271,6752.34,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-15",12,10.15,1013.04,,0.002,0.001,477.697,0.059,0.072,0.0231,8037.699,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-16",10,8.62,946.98,,0.002,0.001,448.049,0.059,0.065,0.0256,7540.504,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-17",9,7.52,853.49,,0.002,0.001,402.592,0.059,0.056,0.023,6774.637,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-18",4,2.61,173.59,,0,0.001,92.578,0.0593,0.037,0.053,1557.134,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-21",5,4.67,421.8,,0.001,0.001,214.184,0.059,0.063,0.0502,3605.207,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-23",8,6.59,691.69,,0.002,0.001,329.701,0.059,0.047,0.0276,5546.729,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-27",8,7.07,698.4,,0.002,0.001,337.569,0.059,0.059,0.0309,5681.334,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-28",14,12.42,1487.6,,0.004,0.001,704.799,0.059,0.063,0.0139,11858.478,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-29",16,14.42,1693.68,,0.004,0.001,790.206,0.0591,0.066,0.0117,13293.232,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-09-30",22,21.2,2529.8,,0.006,0.001,1198.7,0.059,0.078,0.0096,20169.62,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-01",18,16.68,1896.81,,0.005,0.001,904.752,0.059,0.097,0.0181,15224.777,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-02",16,14.52,1700.38,,0.004,0.001,808.464,0.0591,0.071,0.0129,13602.447,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-03",10,8.55,939.39,,0.002,0.001,447.81,0.059,0.052,0.0189,7538.665,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-04",9,7.5,759.85,,0.002,0.001,372.045,0.0591,0.089,0.0378,6259.05,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-05",13,11.55,1386.02,,0.003,0.001,656.036,0.0591,0.065,0.016,11040.964,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-06",11,10.08,1130.84,,0.003,0.001,539.632,0.059,0.057,0.0166,9080.212,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-07",10,8.55,935.5,,0.002,0.001,445.752,0.0592,0.059,0.0202,7499.926,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-13",16,15.23,1750.68,,0.004,0.001,822.844,0.059,0.073,0.0159,13843.726,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-14",24,23.37,2800.34,,0.007,0.001,1298.557,0.059,0.063,0.0059,21848.686,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-15",21,19.58,2319.4,,0.005,0.001,1079.996,0.059,0.083,0.0112,18170.682,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-16",22,20.52,2382.34,,0.006,0.001,1119.104,0.059,0.085,0.011,18831.026,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-17",16,14.6,1693.92,,0.004,0.001,785.958,0.059,0.069,0.0133,13227.488,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-18",13,11.64,1292.16,,0.003,0.001,605.468,0.059,0.066,0.0176,10188.082,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-19",21,19.54,2292.51,,0.005,0.001,1079.219,0.059,0.08,0.0111,18161.068,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-20",14,13.87,1601.24,,0.004,0.001,744.604,0.0591,0.061,0.0139,12526.609,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-21",20,19.01,2237.4,,0.005,0.001,1036.96,0.0591,0.071,0.0095,17449.332,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-22",19,18.26,2113.54,,0.005,0.001,974.784,0.059,0.079,0.0132,16405.456,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-23",16,14.7,1716.06,,0.004,0.001,788.064,0.059,0.046,0.0079,13258.338,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-24",1,0.1,0,,0,0.001,0.42,0.06,0,0.002,7.01,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-26",11,10.52,1190.64,,0.003,0.001,569.744,0.059,0.07,0.0249,9587.52,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-27",21,20.02,2344.6,,0.006,0.001,1103.136,0.059,0.079,0.0101,18561.614,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-28",20,17.88,2108.28,,0.005,0.001,992.556,0.0591,0.079,0.0115,16701.48,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-29",10,8.55,951.85,,0.002,0.001,453.19,0.059,0.055,0.0201,7627.015,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-30",9,7.74,865,,0.002,0.001,415.716,0.0591,0.054,0.0187,6994.926,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-10-31",11,10.17,1193.34,,0.003,0.001,571.472,0.059,0.068,0.0199,9617.501,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-01",20,18.5,2210.86,,0.005,0.001,1042.781,0.059,0.077,0.011,17546.973,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-02",24,23.38,2920.02,,0.007,0.001,1380.228,0.059,0.067,0.006,23223.516,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-03",21,20.25,2436.25,,0.006,0.001,1146.775,0.059,0.09,0.0123,19291.25,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-04",24,24,2962,,0.007,0.001,1384.4,0.059,0.068,0.0058,23292.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-05",24,24,3058,,0.007,0.001,1420.7,0.059,0.068,0.0057,23909.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-06",20,18.15,2148.88,,0.005,0.001,1005.871,0.0591,0.085,0.0121,16923.614,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-07",10,8.48,921.78,,0.002,0.001,431.088,0.059,0.056,0.0185,7255.87,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-13",5,3.92,174.84,,0.001,0.001,141.524,0.059,0.074,0.0768,2381.828,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-16",10,8.75,897.53,,0.002,0.001,430.242,0.0591,0.062,0.0269,7238.899,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-17",11,8.99,964.5,,0.002,0.001,460.923,0.0591,0.058,0.0286,7754.596,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-18",10,8.55,929.57,,0.002,0.001,441.572,0.0591,0.052,0.018,7429.586,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-19",11,9.62,1052.12,,0.002,0.001,486.53,0.059,0.058,0.021,8186.088,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-20",11,9.55,1045.74,,0.002,0.001,489.181,0.0591,0.058,0.0186,8231.014,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-21",5,3.37,212.4,,0.001,0.001,123.061,0.059,0.058,0.0468,2072.521,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-22",10,8.65,901.33,,0.002,0.001,440.643,0.059,0.049,0.0159,7416.442,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-23",10,9.15,948.42,,0.002,0.001,452.763,0.059,0.073,0.0295,7619.355,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-24",11,9.97,1133.82,,0.003,0.001,537.715,0.059,0.066,0.0211,9047.58,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-25",12,9.09,949.4,,0.002,0.001,447.891,0.059,0.078,0.0249,7535.871,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-11-30",11,9.58,1167.7,,0.003,0.001,548.036,0.059,0.06,0.0226,9221.744,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-01",20,16.93,1984.9,,0.005,0.001,934.923,0.0591,0.101,0.0169,15727.314,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-02",22,20.81,2424.9,,0.006,0.001,1121.625,0.059,0.086,0.0124,18872.572,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-03",11,10.17,1272.17,,0.003,0.001,601.998,0.0591,0.057,0.0146,10129.992,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-04",22,20.37,2563.52,,0.006,0.001,1188.233,0.059,0.089,0.012,19996.379,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-05",20,18.58,2266.36,,0.005,0.001,1053.148,0.0591,0.083,0.0134,17719.99,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-06",19,17.56,2114.72,,0.005,0.001,983.024,0.0591,0.081,0.0145,16545.876,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-07",21,20.06,2428.26,,0.006,0.001,1124.134,0.059,0.088,0.0126,18914.732,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-08",24,23.53,2839.35,,0.007,0.001,1297.56,0.059,0.063,0.0059,21835.292,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-09",12,11.65,1338.45,,0.003,0.001,630.72,0.059,0.075,0.0236,10611.535,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-10",22,21.06,2579.42,,0.006,0.001,1201.364,0.059,0.091,0.0124,20216.778,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-11",24,23.25,2765.25,,0.006,0.001,1283,0.059,0.087,0.0098,21591.125,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-12",11,9.74,1239.64,,0.003,0.001,585.902,0.0591,0.059,0.0177,9861.986,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-13",1,0.28,18.2,,0,0.001,7.896,0.059,0.001,0.015,132.748,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-14",11,10.07,1210.21,,0.003,0.001,570.694,0.059,0.045,0.0102,9602.205,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-15",24,24,3085,,0.007,0.001,1427.6,0.059,0.068,0.0057,24017.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-16",24,24,3224,,0.008,0.001,1500.6,0.059,0.071,0.0056,25253.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-17",1,0.28,17.64,,0,0.001,8.148,0.059,0.001,0.015,137.34,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-14",7,6.32,655.08,,0.002,0.001,323.348,0.059,0.054,0.0326,5442.308,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-15",22,21.33,2549.91,,0.006,0.001,1192.06,0.059,0.094,0.0145,20054.132,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-16",24,24,2748,,0.006,0.001,1268.4,0.059,0.064,0.006,21340.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-17",5,4.67,462.26,,0.001,0.001,219.235,0.059,0.012,0.0068,3689.707,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-04",9,7.74,696.9,,0.002,0.001,362.519,0.059,0.089,0.0502,6101.386,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-15",16,14.43,1398.17,,0.004,0.001,704.349,0.0591,0.129,0.0353,11848.948,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-16",24,24,2922,,0.007,0.001,1364,0.059,0.065,0.0057,22953.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-17",20,18.55,2164.24,,0.005,0.001,1002.798,0.0591,0.072,0.0127,16873.685,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-18",19,16.81,1865.04,,0.004,0.001,859.429,0.0591,0.075,0.0162,14462.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-24",5,4.67,310.05,,0.001,0.001,179.67,0.059,0.066,0.0686,3024.014,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-25",1,0.25,15.5,,0,0.001,7.275,0.06,0.001,0.011,122.25,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-26",11,10.07,869.84,,0.002,0.001,450.574,0.059,0.083,0.0334,7582.642,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-30",8,6.12,453,,0.001,0.001,245.346,0.059,0.088,0.0521,4128.66,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-02",6,5.14,316.27,,0.001,0.001,185.415,0.059,0.089,0.071,3120.892,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-04",7,5.86,510.56,,0.001,0.001,267.958,0.059,0.07,0.044,4508.448,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-07",9,8.13,788.68,,0.002,0.001,399.163,0.0592,0.085,0.0451,6715.336,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-10",6,4.97,338.21,,0.001,0.001,193.418,0.059,0.082,0.0683,3254.955,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-15",5,4.9,296.7,,0.001,0.001,177.96,0.0592,0.08,0.0726,2994.14,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-16",1,0.25,14.75,,0,0.001,7.3,0.059,0.001,0.012,122.725,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-27",13,12.28,1060.32,,0.003,0.001,554.732,0.0591,0.131,0.0445,9333.352,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-28",24,24,2575,,0.006,0.001,1230.4,0.059,0.054,0.0052,20705.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-29",24,24,2512,,0.006,0.001,1199.1,0.059,0.058,0.0057,20176.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-04-30",24,24,2500,,0.006,0.001,1202.4,0.059,0.056,0.0055,20231,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-01",24,24,2555,,0.006,0.001,1215.1,0.059,0.055,0.0054,20449.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-02",24,24,2421,,0.006,0.001,1161.1,0.059,0.054,0.0056,19538.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-03",24,24,2525,,0.006,0.001,1214.6,0.059,0.056,0.0055,20435.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-04",24,24,2603,,0.006,0.001,1248.5,0.059,0.063,0.006,21006.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-05",4,3.01,193.32,,0.001,0.0008,109.299,0.059,0.062,0.0635,1840.264,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-06",24,24,2536,,0.006,0.001,1232.3,0.059,0.062,0.006,20734.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-07",24,24,2603,,0.006,0.001,1256.6,0.059,0.063,0.006,21142,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-08",24,24,2723,,0.007,0.001,1318.1,0.059,0.067,0.006,22179.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-09",24,24,2580,,0.006,0.001,1235.7,0.059,0.062,0.006,20791.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-10",24,24,2536,,0.006,0.001,1222.1,0.059,0.062,0.006,20567.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-11",24,23.3,2523.7,,0.006,0.001,1221.72,0.059,0.061,0.0062,20560.48,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-21",11,9.7,765.33,,0.002,0.001,435.522,0.059,0.095,0.0363,7327.391,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-23",9,8.85,922.65,,0.002,0.001,453.13,0.059,0.085,0.0368,7623.695,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-24",19,17.31,1731.08,,0.004,0.0009,847.385,0.0591,0.112,0.0209,14261.515,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-25",22,20.63,2268.17,,0.005,0.001,1083.023,0.059,0.086,0.0129,18224.247,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-26",21,19.5,2432.12,,0.006,0.001,1155.874,0.059,0.08,0.0104,19449.526,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-27",24,24,2918,,0.007,0.001,1360.7,0.059,0.061,0.0053,22893.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-28",24,24,2784,,0.007,0.001,1287.9,0.059,0.062,0.0057,21673.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-29",24,24,3058,,0.007,0.001,1413.2,0.059,0.068,0.0057,23780.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-30",24,24,3053,,0.007,0.001,1399.9,0.059,0.064,0.0055,23557.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-05-31",14,10.11,824.76,,0.002,0.001,426.034,0.0591,0.108,0.0308,7168.91,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-01",21,19.4,2028.41,,0.005,0.001,968.622,0.059,0.079,0.011,16296.884,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-02",22,21.13,2332.13,,0.006,0.001,1106.826,0.059,0.088,0.0112,18623.947,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-03",20,19.34,2374.58,,0.006,0.001,1110.362,0.0591,0.079,0.0118,18681.204,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-04",23,21.49,2466.47,,0.006,0.001,1155.613,0.059,0.09,0.0117,19448.512,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-05",24,23.47,2352.44,,0.006,0.001,1118.845,0.059,0.053,0.0058,18824.72,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-06",13,12.78,1261.08,,0.003,0.001,602.58,0.059,0.027,0.0055,10138.244,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-08",22,21.37,2215.92,,0.005,0.001,1081.214,0.059,0.117,0.0211,18192.254,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-09",23,22.82,2635.74,,0.006,0.001,1228.232,0.059,0.059,0.0057,20666.556,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-10",22,21.15,2480.6,,0.006,0.001,1173.105,0.059,0.081,0.01,19738.845,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-11",19,16.43,1888.73,,0.004,0.001,885.767,0.0591,0.088,0.0169,14905.102,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-17",6,5.35,375.89,,0.001,0.001,210.415,0.0593,0.096,0.0782,3540.913,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-18",15,12.06,1236.04,,0.003,0.001,594.272,0.0591,0.099,0.0249,9998.24,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-21",15,14.88,1512.36,,0.004,0.001,746.364,0.0591,0.108,0.0294,12562.784,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-22",22,19.46,2008.06,,0.005,0.001,957.78,0.0591,0.094,0.0147,16117.305,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-23",15,12.2,1235.08,,0.003,0.001,605.244,0.0591,0.086,0.0213,10183.492,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-24",17,14.18,1519.8,,0.004,0.001,720.236,0.0591,0.087,0.0181,12121.944,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-25",16,13.28,1367.93,,0.003,0.001,652.565,0.059,0.085,0.0202,10981.416,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-26",17,13.94,1482.67,,0.004,0.001,706.872,0.0591,0.086,0.0187,11895.409,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-27",10,8.67,919.49,,0.002,0.001,445.932,0.0591,0.06,0.0267,7504.466,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-05",4,3.87,190.14,,0.001,0.001,124.341,0.0593,0.092,0.109,2092.278,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-06",24,24,2697,,0.006,0.001,1275.9,0.059,0.06,0.0056,21469.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-07",24,24,2635,,0.006,0.001,1244.5,0.059,0.06,0.0057,20940.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-08",18,17.08,1871.48,,0.005,0.001,895.564,0.0591,0.094,0.0182,15072.512,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-09",18,17.3,1859.95,,0.004,0.001,890.115,0.059,0.088,0.0159,14980.175,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-10",19,17.36,1979.74,,0.005,0.001,925.605,0.059,0.11,0.0222,15576.586,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-11",19,17.4,1960.32,,0.005,0.001,923.84,0.0591,0.113,0.0208,15544.364,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-12",19,17.35,1997.75,,0.005,0.001,944.443,0.0591,0.11,0.0194,15891.403,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-13",22,20.04,2081.26,,0.005,0.001,988.53,0.059,0.103,0.0157,16636.376,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-14",21,17.92,1943.87,,0.005,0.001,904.913,0.059,0.093,0.0149,15230.113,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-15",23,21.49,2367.62,,0.006,0.001,1113.638,0.059,0.078,0.01,18737.528,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-16",21,19.38,2104.07,,0.005,0.001,1005.78,0.059,0.073,0.0104,16923.768,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-17",18,17.01,1854.67,,0.004,0.001,887.588,0.059,0.088,0.0177,14933.886,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-18",24,24,2675,,0.006,0.001,1263.2,0.059,0.06,0.0056,21251.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-19",19,16.81,1820.01,,0.004,0.001,861.79,0.0591,0.076,0.0134,14499.044,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-20",19,16.58,1798.45,,0.004,0.0009,850.161,0.0591,0.09,0.0161,14309.513,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-21",18,16.62,1857.61,,0.004,0.001,876.21,0.059,0.087,0.0168,14743.198,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-22",14,13.82,1500.86,,0.004,0.001,724.908,0.059,0.078,0.0198,12200.266,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-23",18,16.85,1849.55,,0.004,0.001,886.645,0.059,0.074,0.0153,14920.285,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-24",18,17.06,1814.32,,0.004,0.001,871.19,0.0591,0.08,0.0157,14660.432,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-25",23,22.28,2414.86,,0.006,0.001,1146.398,0.059,0.075,0.0096,19291.144,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-26",24,24,2675,,0.006,0.001,1268.7,0.059,0.058,0.0054,21350.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-27",24,22.75,2367.36,,0.006,0.001,1131.666,0.059,0.057,0.0066,19047.145,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-28",19,17.43,1957.65,,0.005,0.001,931.324,0.059,0.103,0.0184,15670.272,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-29",19,17.48,1755.85,,0.004,0.001,850.042,0.059,0.096,0.0174,14305.192,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-30",19,17.4,1675.6,,0.004,0.001,813.2,0.0591,0.092,0.0175,13684.63,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-07-31",18,16.62,2259.81,,0.006,0.001,1094.682,0.0591,0.092,0.0158,18418.993,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-01",19,17.42,2074.65,,0.005,0.001,1005.855,0.0591,0.122,0.0206,16921.949,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-02",18,17.2,1684.9,,0.004,0.001,807.526,0.059,0.096,0.0194,13584.207,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-03",18,15.95,1716.03,,0.004,0.001,823.248,0.0591,0.082,0.0181,13850.148,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-04",14,12.94,1570.39,,0.004,0.001,750.187,0.0591,0.067,0.0149,12621.165,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-05",20,19.12,2257,,0.005,0.001,1039.268,0.059,0.084,0.0118,17487.16,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-06",24,24,2903,,0.007,0.001,1340.1,0.059,0.067,0.006,22548.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-07",24,24,2616,,0.006,0.001,1248.2,0.059,0.063,0.006,21006.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-08",19,17.43,1971.74,,0.005,0.001,936.174,0.059,0.068,0.0097,15753.67,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-09",24,23.33,2571.07,,0.006,0.001,1226.883,0.059,0.062,0.0061,20643.733,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-10",21,19.83,1974.59,,0.005,0.001,951.454,0.059,0.116,0.02,16011.425,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-11",19,17.45,1890.05,,0.005,0.001,892.97,0.0591,0.097,0.0169,15028.23,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-12",14,12.08,1078.14,,0.003,0.001,541.328,0.059,0.103,0.0272,9103.776,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-13",24,24,2971,,0.007,0.001,1381.8,0.059,0.065,0.0056,23250.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-14",24,24,3156,,0.007,0.001,1474.9,0.059,0.07,0.0056,24814.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-15",24,24,3215,,0.008,0.001,1510.4,0.059,0.073,0.0058,25415.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-16",24,24,3175,,0.008,0.001,1497.4,0.059,0.07,0.0056,25197.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-17",24,24,3136,,0.007,0.001,1473.2,0.059,0.067,0.0054,24790,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-18",24,24,3070,,0.007,0.001,1436.1,0.059,0.068,0.0056,24169.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-19",24,24,3141,,0.007,0.001,1476.5,0.059,0.073,0.0059,24841.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-20",24,24,3050,,0.007,0.001,1415.7,0.059,0.069,0.0058,23820.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-21",24,24,3052,,0.007,0.001,1409.6,0.059,0.07,0.0059,23720.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-22",19,17.4,1982.95,,0.005,0.001,936.325,0.059,0.1,0.0171,15758.21,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-23",20,18.45,2208.05,,0.005,0.001,1028.51,0.059,0.072,0.01,17309.085,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-24",19,17.65,2090,,0.005,0.001,977.045,0.0591,0.092,0.0147,16441.615,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-25",19,17.38,2000.35,,0.005,0.0009,938.931,0.059,0.09,0.0148,15803.828,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-26",24,24,2790,,0.007,0.001,1291,0.059,0.054,0.005,21724.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-27",24,24,2782,,0.007,0.001,1287.9,0.059,0.054,0.005,21668.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-28",24,24,2781,,0.007,0.001,1291.8,0.059,0.054,0.005,21737.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-29",24,23.41,2749.17,,0.006,0.001,1268.109,0.059,0.081,0.0092,21337.532,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-30",24,24,2968,,0.007,0.001,1359.4,0.059,0.063,0.0055,22874.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-08-31",24,23.33,2879.74,,0.007,0.001,1335.985,0.059,0.062,0.0057,22482.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-01",21,20.27,2172.51,,0.005,0.001,1045.511,0.059,0.077,0.0114,17593.188,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-02",22,20.5,2182.25,,0.005,0.001,1049.494,0.059,0.073,0.0098,17658.147,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-03",24,22.65,2536.9,,0.006,0.001,1189.205,0.059,0.087,0.0122,20007.26,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-04",24,24,3059,,0.007,0.001,1417.4,0.059,0.06,0.005,23850.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-05",24,24,3061,,0.007,0.001,1426.6,0.059,0.06,0.005,24005.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-06",24,24,3116,,0.007,0.001,1470.9,0.059,0.062,0.005,24750.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-07",20,18.35,2190.65,,0.005,0.001,1045.76,0.0591,0.075,0.0138,17593.52,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-08",24,24,3083,,0.007,0.001,1440,0.059,0.067,0.0055,24229,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-09",24,23.35,2821.35,,0.007,0.001,1305.445,0.059,0.06,0.0057,21967.265,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-10",14,11.63,1083.01,,0.003,0.001,535.71,0.0591,0.103,0.0282,9014.101,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-13",11,10.39,1063.16,,0.003,0.001,533.771,0.0591,0.108,0.0407,8980.586,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-14",8,6.78,672.3,,0.002,0.001,335.602,0.059,0.065,0.0314,5644.508,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-15",20,17.45,1750.4,,0.004,0.001,841.391,0.0591,0.114,0.0219,14158.341,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-16",15,11.57,1170.02,,0.003,0.001,558.462,0.059,0.087,0.0253,9396.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-17",14,10.92,1132.4,,0.003,0.001,540.223,0.0591,0.09,0.0236,9090.084,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-18",7,6.02,502.4,,0.001,0.001,264.08,0.059,0.057,0.0363,4443.65,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-19",20,17.92,1812.56,,0.004,0.001,886.215,0.0591,0.097,0.0167,14916.161,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-20",6,5.45,612.71,,0.001,0.001,293.817,0.059,0.044,0.028,4943.104,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-21",5,4.67,420.95,,0.001,0.001,214.11,0.059,0.062,0.049,3603.852,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-23",14,11.57,1012.81,,0.003,0.001,511.329,0.059,0.145,0.0455,8606.73,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-26",6,5.14,363.68,,0.001,0.001,201.2,0.059,0.092,0.0742,3385.153,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-27",13,10.37,960.12,,0.002,0.001,465.754,0.0592,0.094,0.0319,7835.342,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-28",20,17.46,1867.7,,0.005,0.001,906.929,0.059,0.134,0.0254,15258.313,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-29",20,17.89,1966.76,,0.005,0.001,930.851,0.059,0.105,0.0171,15664.067,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-09-30",22,21.18,2523.72,,0.006,0.001,1191.74,0.059,0.082,0.0099,20052.612,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-01",18,16.63,1897.62,,0.005,0.001,904.693,0.059,0.101,0.0192,15228.454,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-02",21,17.94,1971.9,,0.005,0.001,950.523,0.059,0.1,0.0152,15994.227,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-03",15,11.95,1205.7,,0.003,0.001,587.541,0.0591,0.102,0.0255,9882.588,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-04",14,10.95,1049.24,,0.003,0.001,518.852,0.0591,0.128,0.0341,8731.405,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-05",18,15.65,1685.01,,0.004,0.001,815.089,0.059,0.128,0.0272,13717.349,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-06",17,14.5,1554.85,,0.004,0.001,748.909,0.0591,0.097,0.019,12603.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-07",16,13.1,1347.93,,0.003,0.001,652.15,0.059,0.099,0.0242,10973.661,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-10",18,17.7,1635.5,,0.004,0.001,805.35,0.0591,0.117,0.0264,13553.315,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-11",21,20.05,2076.31,,0.005,0.001,993.188,0.059,0.091,0.0159,16712.376,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-12",21,19.49,2173.71,,0.005,0.001,1030.281,0.059,0.074,0.0101,17335.32,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-13",21,19.71,2182.19,,0.005,0.001,1033.282,0.0591,0.108,0.016,17385.975,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-14",24,23.37,2797.71,,0.007,0.001,1295.368,0.059,0.061,0.0058,21794.188,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-15",21,19.55,2326.71,,0.005,0.001,1083.272,0.059,0.084,0.0118,18228.066,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-16",22,20.51,2379.05,,0.006,0.001,1116.707,0.059,0.085,0.0113,18790.788,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-17",21,19.11,2129.51,,0.005,0.001,1010.4,0.059,0.112,0.0174,17002.731,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-18",18,15.07,1564.69,,0.004,0.001,747.812,0.059,0.102,0.0208,12584.489,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-19",21,19.5,2293.6,,0.005,0.001,1079.237,0.059,0.077,0.011,18159.99,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-20",20,18.37,2037.88,,0.005,0.001,960.846,0.059,0.097,0.0171,16169.079,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-21",20,18.97,2252.65,,0.005,0.001,1050.577,0.059,0.075,0.0098,17678.378,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-22",24,23.07,2656.1,,0.006,0.001,1258.333,0.059,0.092,0.0101,21176.573,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-23",17,15.13,1730.64,,0.004,0.001,798.142,0.059,0.068,0.0121,13429.319,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-24",11,10.57,1114.83,,0.003,0.001,540.222,0.059,0.074,0.0288,9093.609,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-25",21,19.14,2046.24,,0.005,0.001,983.756,0.059,0.08,0.0119,16554.536,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-26",22,21.08,2405,,0.006,0.001,1149.9,0.059,0.082,0.0101,19352.848,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-27",21,19.95,2331.57,,0.005,0.001,1085.033,0.059,0.078,0.0102,18254.67,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-28",20,17.84,2110.13,,0.005,0.001,993.221,0.0591,0.08,0.012,16709.768,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-29",17,13.98,1474.66,,0.004,0.001,701.366,0.0591,0.105,0.0229,11799.254,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-30",16,13.32,1414.33,,0.003,0.001,680.408,0.0591,0.088,0.0205,11449.662,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-10-31",18,15.7,1725.28,,0.004,0.001,812.478,0.0591,0.119,0.0237,13671.689,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-01",20,18.47,2193.7,,0.005,0.001,1022.403,0.0591,0.077,0.0114,17206.053,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-02",24,23.37,2851.34,,0.007,0.001,1294.679,0.059,0.064,0.0061,21784.086,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-03",21,20.18,2413.44,,0.006,0.001,1122.78,0.059,0.092,0.0125,18893.02,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-04",24,24,2950,,0.007,0.001,1368.4,0.059,0.064,0.0055,23023,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-05",24,24,3072,,0.007,0.001,1427.8,0.059,0.065,0.0054,24022.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-06",20,18.1,2127.68,,0.005,0.001,981.426,0.0591,0.089,0.0133,16515.374,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-07",16,12.97,1351.43,,0.003,0.001,640.17,0.0591,0.113,0.0256,10770.73,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-13",5,3.88,170.38,,0.001,0.001,138.512,0.0592,0.074,0.0798,2330.106,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-16",20,19.09,1947.03,,0.005,0.001,956.441,0.059,0.161,0.0293,16094.309,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-17",20,18.08,1887.24,,0.005,0.001,894.336,0.059,0.137,0.026,15053.527,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-18",15,12.86,1341.62,,0.003,0.001,630.917,0.0591,0.079,0.0199,10617.302,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-19",17,13.9,1490.6,,0.004,0.001,715.275,0.0591,0.079,0.0189,12032.935,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-20",17,14.06,1466.32,,0.004,0.001,694.409,0.0591,0.094,0.0203,11685.765,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-21",12,8.67,748.14,,0.002,0.001,386.928,0.0591,0.086,0.0279,6511.301,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-22",16,13.4,1322.04,,0.003,0.001,653.368,0.059,0.095,0.0221,10993.643,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-23",20,18.4,2054.45,,0.005,0.001,974.932,0.0591,0.085,0.0129,16406.54,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-24",16,14.1,1541.28,,0.004,0.001,734.826,0.0591,0.104,0.0238,12363.52,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-25",12,9.03,956.41,,0.002,0.001,455.072,0.0591,0.081,0.0275,7659.854,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-11-30",18,15.68,1637.69,,0.004,0.001,798.781,0.059,0.149,0.0344,13443.094,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-01",20,16.83,1989.69,,0.005,0.001,939.868,0.0592,0.1,0.0167,15813.846,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-02",22,20.77,2428.44,,0.006,0.001,1124.618,0.059,0.083,0.0118,18923.392,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-03",17,14.88,1723.88,,0.004,0.001,818.791,0.0591,0.098,0.0191,13779.735,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-04",22,20.29,2570.51,,0.006,0.001,1197.273,0.059,0.09,0.0138,20143.796,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-05",20,18.55,2256.08,,0.005,0.001,1037.26,0.0591,0.083,0.0144,17457.544,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-06",19,17.54,2120.6,,0.005,0.001,986.787,0.0591,0.079,0.015,16607.719,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-07",21,20.04,2431.67,,0.006,0.001,1128.675,0.059,0.092,0.0141,18990.597,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-08",24,23.52,2840.96,,0.007,0.001,1296.408,0.059,0.062,0.0058,21813.532,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-09",21,20.13,2300.26,,0.006,0.001,1089.073,0.059,0.083,0.0106,18330.872,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-10",22,21.04,2584.09,,0.006,0.001,1204.543,0.059,0.093,0.013,20268.084,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-11",24,23.2,2767.4,,0.006,0.001,1283.52,0.059,0.087,0.0099,21602.28,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-12",17,14.22,1670.6,,0.004,0.001,799.514,0.0591,0.103,0.0241,13456.784,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-13",1,0.27,18.9,,0,0.001,8.073,0.059,0.001,0.02,135.891,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-14",22,21.33,2429.88,,0.006,0.001,1166.863,0.059,0.138,0.022,19632.843,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-15",24,24,3089,,0.007,0.001,1429.9,0.059,0.065,0.0054,24058.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-16",24,24,3216,,0.008,0.001,1500.3,0.059,0.069,0.0054,25247.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-17",1,0.27,17.82,,0,0.001,8.235,0.059,0.001,0.016,138.591,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-18",1,0.15,0,,0,0.001,1.095,0.06,0.001,0.059,18.33,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Tracy Combined Cycle Power Plant",55933,"TPP2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction,Dry Low NOx Burners",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-27",5,4.25,169.5,,0.001,0.001,105.175,0.0596,0.02,0.0358,1768.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-12",13,11.5,481.75,,0.001,0.001,295.95,0.0595,0.035,0.025,4980.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-13",13,11.5,481.75,,0.001,0.001,296.825,0.0594,0.034,0.0225,4994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-03",8,6.5,253.5,,0.001,0.001,158.95,0.0593,0.021,0.0358,2674.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-04",7,6.25,231.25,,0.001,0.001,146.375,0.059,0.02,0.0387,2465.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-05",1,0.25,2.5,,0,0.001,2.8,0.059,0.001,0.043,47.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-10",8,6.5,249.75,,0.001,0.001,157.375,0.0591,0.023,0.0439,2648.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-11",8,6.5,252.75,,0.001,0.001,157.775,0.0591,0.022,0.052,2655.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-12",8,6.5,263,,0.001,0.001,162.65,0.0591,0.021,0.0308,2736.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-13",8,6.5,265.5,,0.001,0.001,165.2,0.0591,0.021,0.0308,2778.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-15",1,0.5,11,,0,0.001,8.3,0.059,0.007,0.105,140.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-27",7,6.25,249,,0.001,0.001,154.525,0.0591,0.019,0.0249,2601.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-28",1,0.25,1.5,,0,0.001,2.3,0.059,0.001,0.045,38.825,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-29",8,6.5,245.75,,0.001,0.001,156.225,0.0593,0.024,0.0331,2629.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-30",8,6.5,262.75,,0.001,0.001,162.725,0.0593,0.02,0.0259,2737.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-07-31",9,7.5,301.5,,0.001,0.001,186.9,0.0591,0.024,0.0333,3146.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-01",8,6.5,259.25,,0.001,0.001,160.45,0.0593,0.022,0.0384,2699.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-13",8,6.5,265.25,,0.001,0.001,162.875,0.0591,0.022,0.0328,2741.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-14",12,10.5,434.5,,0.001,0.001,267.875,0.0591,0.031,0.0214,4509.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-15",11,9.5,386,,0.001,0.001,237.9,0.0592,0.028,0.0221,4002.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-16",11,9.5,386.75,,0.001,0.001,237.3,0.0591,0.028,0.0246,3992.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-17",14,12.5,503.25,,0.002,0.001,312.725,0.0594,0.035,0.0216,5260.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-18",14,12.5,497.75,,0.002,0.001,312.5,0.0592,0.035,0.0187,5258.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-19",12,11.25,456.25,,0.001,0.001,284.175,0.0591,0.033,0.0253,4784.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-20",11,9.5,365.5,,0.001,0.001,232.35,0.0592,0.028,0.0316,3911.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-21",10,8.5,340.25,,0.001,0.001,214.2,0.0593,0.026,0.0263,3604.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-22",8,6.5,262,,0.001,0.001,165.425,0.0594,0.021,0.0275,2780.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-24",9,7.5,303.75,,0.001,0.001,191.4,0.0592,0.024,0.0274,3219.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-25",8,6.5,261.75,,0.001,0.001,163.3,0.0591,0.019,0.0226,2746.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-26",9,7.5,297.75,,0.001,0.001,185.925,0.0593,0.026,0.0434,3127.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-27",8,6.5,262.75,,0.001,0.001,165.15,0.0594,0.038,0.0251,2776.575,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-28",8,6.5,265.25,,0.001,0.001,164.25,0.0593,0.02,0.0261,2763.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-04",8,6.5,259.25,,0.001,0.001,160.7,0.0593,0.021,0.0323,2703.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-05",11,9.75,379.25,,0.001,0.001,241.975,0.0595,0.03,0.0259,4068.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-06",10,8.5,339,,0.001,0.001,212.975,0.0592,0.028,0.0314,3583.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-07",8,6.5,264.75,,0.001,0.001,163.7,0.0591,0.021,0.0296,2756.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-08",8,6.5,264.75,,0.001,0.001,163.975,0.0593,0.02,0.0248,2759.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-23",15,13.5,553.25,,0.002,0.001,341.25,0.0593,0.039,0.0219,5738.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-28",8,6.5,260.25,,0.001,0.001,161.625,0.0594,0.021,0.033,2718.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-29",8,6.75,275.75,,0.001,0.001,169.95,0.0591,0.024,0.037,2859.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-09-30",9,7.5,305.75,,0.001,0.001,189.575,0.0591,0.025,0.0371,3191.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-01",11,9.5,382.5,,0.001,0.001,238.55,0.0593,0.029,0.0271,4014.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-02",10,8.5,344,,0.001,0.001,214.075,0.0593,0.027,0.0324,3600.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-03",8,6.5,245.25,,0.001,0.001,156.15,0.0593,0.021,0.0335,2626.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-05",8,6.5,247.5,,0.001,0.001,157.225,0.0591,0.023,0.0458,2645.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-06",8,6.25,245.5,,0.001,0.001,154.975,0.0596,0.026,0.0466,2605.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-12",8,6.5,255.25,,0.001,0.001,160.95,0.0593,0.021,0.0321,2708.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-13",8,6.5,260.75,,0.001,0.001,164.3,0.0591,0.022,0.0354,2763.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-14",8,6.5,265.5,,0.001,0.001,166.775,0.0591,0.022,0.0339,2807.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-15",8,6.5,264.25,,0.001,0.001,165.25,0.0591,0.023,0.0399,2779.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-16",8,6.5,261.5,,0.001,0.001,164.225,0.0594,0.022,0.034,2763.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-17",8,6.5,246.25,,0.001,0.001,156.175,0.0594,0.021,0.0353,2628.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-20",8,6.5,245.75,,0.001,0.001,157.15,0.0591,0.021,0.035,2644.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Agua Mansa Power",55951,"AMP-1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-16",3,1.33,28.5,,0,0.001,21.045,0.059,0.007,0.114,354.635,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-17",2,1.27,25.43,,0,0.001,19.127,0.059,0.008,0.046,322.74,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-02",3,1.38,26.42,,0,0.001,20.526,0.0593,0.007,0.1047,345.72,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-14",3,1.57,56.7,,0,0.001,35.096,0.0593,0.009,0.0543,589.9,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-24",3,1.75,47.45,,0,0.001,32.435,0.0593,0.01,0.0473,544.995,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-25",3,1.52,32.48,,0,0.001,23.856,0.059,0.008,0.077,402.132,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-26",3,2,46.94,,0,0.001,33.342,0.059,0.009,0.0437,561.734,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-09",3,1.72,36.6,,0,0.001,26.942,0.06,0.019,0.133,452.031,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-12",5,4.02,127.47,,0,0.001,81.816,0.0594,0.011,0.025,1376.671,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-13",3,2.34,98.2,,0,0.001,59.546,0.059,0.011,0.0263,1002.474,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-14",6,5.65,230.56,,0.001,0.001,140.957,0.0592,0.015,0.0143,2371.131,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-17",2,1.3,25.45,,0,0.001,19.503,0.06,0.007,0.043,327.26,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-22",3,2.07,42.81,,0,0.001,31.721,0.0597,0.009,0.0407,533.326,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-05",3,2.02,40.16,,0,0.001,30.142,0.0593,0.008,0.0483,506.824,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-07",1,0.27,0,,0,0.001,1.755,0.059,0.005,0.315,29.673,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-09",2,1.27,26.64,,0,0.001,19.54,0.0595,0.009,0.0535,328.713,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-10",2,1.32,40.38,,0,0.001,26.484,0.059,0.008,0.0495,445.878,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-02",3,1.55,31.16,,0,0.001,23.259,0.059,0.008,0.0677,392.038,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-03",5,3.25,68.42,,0,0.001,49.844,0.0596,0.009,0.0626,837.813,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-07",5,3.44,69.24,,0,0.001,51.544,0.0594,0.009,0.0646,867.72,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-08",6,3.09,89.74,,0,0.001,59.309,0.0592,0.015,0.0725,997.538,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-09",4,3.09,109.2,,0,0.001,68.401,0.059,0.01,0.0283,1150.46,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-18",11,8.26,174.11,,0.001,0.001,128.136,0.0593,0.02,0.0529,2156.852,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-19",6,4.35,92.62,,0,0.001,67.361,0.0593,0.009,0.051,1133.626,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-20",5,3.34,70,,0,0.001,51.33,0.0594,0.008,0.0566,864.068,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-21",7,4.78,98.41,,0,0.001,72.568,0.0594,0.015,0.0446,1222.017,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-22",9,8.12,364.32,,0.001,0.001,214.232,0.0593,0.015,0.0314,3605.944,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-23",9,6.37,158.88,,0.001,0.001,109.629,0.0593,0.012,0.0513,1843.721,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-24",7,5.37,114.35,,0,0.001,82.945,0.0593,0.031,0.0969,1395.809,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-25",5,3.24,70.16,,0,0.001,50.648,0.0592,0.009,0.0928,852.684,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-26",11,9.36,348.44,,0.001,0.001,215.456,0.0597,0.014,0.0287,3621.072,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-27",10,9.13,359.72,,0.001,0.001,219.102,0.0593,0.015,0.0165,3686.643,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-01",7,5.34,126.34,,0,0.001,89.478,0.0596,0.01,0.0434,1503.692,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-03",6,4.97,144.58,,0,0.001,95.429,0.0592,0.009,0.0215,1605.77,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-04",3,1.4,27.52,,0,0.001,20.564,0.0593,0.005,0.072,346.872,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-09",4,3.27,134.34,,0,0.001,80.782,0.0593,0.013,0.0238,1358.319,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-10",4,3,99.71,,0,0.001,62.951,0.0598,0.01,0.0245,1058.122,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-11",2,0.42,0,,0,0.001,2.71,0.059,0.006,0.2735,45.72,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-15",3,2,39,,0,0.001,29.762,0.059,0.01,0.058,501.288,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-21",5,3.29,69.37,,0,0.001,50.82,0.0592,0.008,0.0582,855.77,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-22",4,2.35,60.21,,0,0.001,41.176,0.0598,0.007,0.0548,692.996,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-23",5,3.41,71.84,,0,0.001,52.524,0.0592,0.007,0.048,884.62,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-24",5,3.36,70.76,,0,0.001,51.684,0.059,0.006,0.0534,871.372,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-02",6,4.71,142,,0,0.001,94.083,0.0595,0.009,0.064,1582.623,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-03",3,1.54,35.08,,0,0.001,25.208,0.0593,0.007,0.0663,423.646,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-04",4,2.5,103.88,,0,0.001,62.384,0.0598,0.009,0.052,1049.066,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-05",2,1.22,25.74,,0,0.001,18.914,0.0595,0.005,0.0695,317.764,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-06",1,0.12,0.48,,0,0.001,0.936,0.06,0.001,0.135,15.72,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-09",4,2.24,46.28,,0,0.001,34.296,0.0593,0.007,0.0728,576.48,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-10",2,1.26,46.6,,0,0.001,28.656,0.0595,0.008,0.053,481.636,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-11",7,6.29,238.54,,0.001,0.001,146.72,0.0593,0.012,0.0189,2469.971,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-12",5,4.05,160.39,,0,0.001,97.745,0.0592,0.01,0.0234,1645.436,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-14",7,4.58,94.26,,0,0.001,69.689,0.0593,0.011,0.0587,1172.495,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-15",6,3.61,73.09,,0,0.001,54.448,0.0592,0.01,0.0637,916.559,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-16",9,7.25,156.17,,0.001,0.001,113.407,0.0593,0.011,0.037,1907.834,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-17",6,4.35,92.62,,0,0.001,67.404,0.0592,0.008,0.0448,1134.973,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-18",6,4.4,94.64,,0,0.001,69.192,0.0593,0.009,0.0422,1164.832,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-19",6,4.35,91.93,,0,0.001,67.051,0.059,0.009,0.0497,1128.839,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-20",5,3.33,69.85,,0,0.001,50.825,0.0592,0.008,0.0516,855.489,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-21",9,7.3,157.52,,0.001,0.001,113.968,0.059,0.009,0.0372,1917.25,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-22",6,4.35,92.86,,0,0.001,67.4,0.0598,0.007,0.0517,1132.027,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-24",7,5.54,118.58,,0,0.001,86.218,0.0596,0.009,0.0324,1448.794,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-26",3,2.77,105.44,,0,0.001,64.765,0.0593,0.011,0.021,1089.932,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-27",5,3.67,103.32,,0,0.001,69.522,0.0594,0.009,0.034,1169.412,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-28",3,1.3,25.48,,0,0.001,19.196,0.059,0.006,0.0817,323.74,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-29",5,3.8,117.28,,0,0.001,76.044,0.0592,0.01,0.0368,1278.984,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-30",6,4.97,167.73,,0.001,0.001,106.155,0.0592,0.011,0.025,1786.301,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-07-31",3,1.3,25.71,,0,0.001,19.346,0.0593,0.007,0.0913,324.956,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-01",3,1.37,26.73,,0,0.001,20.222,0.059,0.006,0.0813,340.728,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-02",12,10.25,222.17,,0.001,0.001,161.208,0.0593,0.014,0.0304,2713.854,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-03",6,4.3,91.36,,0,0.001,66.654,0.0593,0.008,0.047,1121.584,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-09",9,7.25,156.18,,0.001,0.001,114.089,0.0593,0.01,0.038,1920.913,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-12",7,4.79,131.44,,0,0.001,88.61,0.059,0.016,0.0409,1491.946,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-13",8,7.27,299.93,,0.001,0.001,179.832,0.0593,0.017,0.0203,3025.284,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-14",11,9.09,270.77,,0.001,0.001,176.593,0.0594,0.016,0.0291,2970.034,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-15",15,13.86,509.64,,0.002,0.001,311.534,0.0592,0.022,0.0149,5242.966,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-16",10,8.6,333.5,,0.001,0.001,203.24,0.0593,0.014,0.0185,3418.97,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-17",15,14.17,450.27,,0.001,0.001,291.687,0.0592,0.017,0.0078,4910.224,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-18",15,14.38,395.24,,0.001,0.001,266.292,0.0593,0.018,0.0087,4480.52,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-19",7,5.44,115.39,,0,0.001,84.204,0.0591,0.009,0.0316,1417.291,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-20",8,6.33,133.78,,0,0.001,97.922,0.0593,0.01,0.0385,1649.536,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-21",8,6.28,136.18,,0.001,0.001,99.144,0.0594,0.009,0.0368,1667.88,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-22",5,4.05,101.02,,0,0.001,70.132,0.0594,0.008,0.0332,1179.481,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-24",6,3.05,81.5,,0,0.001,55.226,0.0597,0.01,0.0527,928.71,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-25",7,3.72,74.47,,0,0.001,55.395,0.0594,0.013,0.0729,932.122,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-26",14,11.93,257.59,,0.001,0.001,185.089,0.0592,0.015,0.0306,3117.661,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-27",14,12.6,272.56,,0.001,0.001,196.484,0.0592,0.017,0.0212,3307.388,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-28",14,12.23,265.79,,0.001,0.001,192.66,0.0595,0.015,0.0272,3241.207,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-29",15,11.5,246.73,,0.001,0.001,178.57,0.0591,0.018,0.0396,3006.821,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-30",15,10.76,226.6,,0.001,0.001,166.131,0.0594,0.018,0.0449,2794.814,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-08-31",15,11.55,247.48,,0.001,0.001,179.736,0.0593,0.018,0.0384,3025.458,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-01",15,12.53,266.37,,0.001,0.001,194.447,0.0593,0.018,0.0306,3270.44,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-02",12,10.3,221.3,,0.001,0.001,160.918,0.0592,0.012,0.0254,2710.324,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-03",13,12.3,265.4,,0.001,0.001,193.46,0.0595,0.014,0.0139,3253.49,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-04",16,11.18,235.21,,0.001,0.001,172.316,0.0594,0.022,0.0521,2899.5,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-05",12,9.93,227.2,,0.001,0.001,163.103,0.0595,0.013,0.0293,2741.435,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-06",7,6.21,214.72,,0.001,0.001,134.363,0.0591,0.011,0.0143,2261.572,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-07",4,2.33,48.2,,0,0.001,35.585,0.0595,0.007,0.0585,598.998,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-09",14,10.68,228.52,,0.001,0.001,166.168,0.0594,0.018,0.0398,2795.052,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-10",3,1.27,24.88,,0,0.001,18.991,0.0593,0.005,0.0837,319.227,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-14",2,1.22,34.34,,0,0.001,22.832,0.0595,0.007,0.0355,384.154,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-16",3,1.3,25.5,,0,0.001,19.22,0.059,0.005,0.083,323.95,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-17",5,3.22,82.82,,0,0.001,57.139,0.059,0.012,0.052,961.964,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-18",3,2.04,47.96,,0,0.001,33.958,0.0593,0.007,0.0323,571.912,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-19",6,4.18,90.7,,0,0.001,65.789,0.0593,0.007,0.028,1105.762,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-20",3,1.45,31.6,,0,0.001,22.946,0.0597,0.004,0.042,385.59,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-21",4,2.44,50.56,,0,0.001,37.488,0.0595,0.007,0.0588,629.932,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-23",4,2.45,51.08,,0,0.001,37.668,0.0598,0.007,0.0573,633.004,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-24",2,1.4,27.12,,0,0.001,20.876,0.0595,0.006,0.0415,351.08,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-28",6,4.8,181.84,,0.001,0.001,111.684,0.059,0.013,0.0362,1880.872,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-29",7,4.9,116.54,,0,0.001,82.703,0.0597,0.013,0.0374,1389.05,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-09-30",6,4.76,109.46,,0,0.001,78.1,0.0593,0.01,0.035,1313.73,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-01",6,5.17,135.66,,0,0.001,92.711,0.0592,0.011,0.0178,1559.941,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-02",6,4.28,91.4,,0,0.001,67.108,0.0595,0.008,0.0557,1128.656,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-03",3,1.82,58.58,,0,0.001,37.774,0.0597,0.008,0.073,635.9,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-04",5,3.1,72.6,,0,0.001,51.912,0.0594,0.014,0.0452,873.459,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-05",4,3.58,97.34,,0,0.001,65.512,0.059,0.009,0.0173,1102.428,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-06",2,1.29,33.79,,0,0.001,22.608,0.059,0.024,0.1135,380.513,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-07",3,1.82,36.98,,0,0.001,27.206,0.0593,0.006,0.0487,457.906,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-10",3,1.55,38.93,,0,0.001,26.796,0.0593,0.007,0.0853,450.878,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-12",14,10.74,229.66,,0.001,0.001,165.918,0.0592,0.018,0.0398,2790.768,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-13",17,13.61,291.09,,0.001,0.001,210.678,0.0592,0.018,0.0384,3546.568,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-14",20,16.72,362,,0.001,0.001,261.268,0.0592,0.022,0.0312,4398.818,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-15",14,11.23,259.83,,0.001,0.001,182.871,0.0592,0.017,0.0314,3079.144,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-16",19,15.62,339.8,,0.001,0.001,245.101,0.0594,0.024,0.0318,4122.949,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-17",17,13.74,312.59,,0.001,0.001,220.91,0.0592,0.019,0.0335,3720.597,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-18",9,7.39,159.07,,0.001,0.001,114.832,0.0594,0.01,0.03,1931.769,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-19",14,10.69,252.74,,0.001,0.001,177.026,0.0591,0.016,0.0332,2978.915,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-20",12,10.35,224.39,,0.001,0.001,161.523,0.0593,0.013,0.025,2718.946,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-21",5,3.84,96.52,,0,0.001,66.704,0.0596,0.009,0.037,1121.364,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-22",2,1.04,19.8,,0,0.001,14.92,0.06,0.006,0.098,250.32,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-25",5,3.34,72,,0,0.001,52.442,0.0592,0.009,0.0602,882.758,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-26",8,4.63,94.2,,0,0.001,70.597,0.0595,0.015,0.076,1186.765,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-27",4,2.07,65.14,,0,0.001,42.512,0.0593,0.007,0.023,715.33,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-29",4,2.39,50.81,,0,0.001,37.199,0.0593,0.007,0.0518,625.86,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-10-31",4,2.35,48.86,,0,0.001,35.797,0.0598,0.006,0.0685,601.414,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-02",4,3.06,78.58,,0,0.001,54.23,0.0593,0.007,0.0205,912.892,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-03",4,2.8,70.88,,0,0.001,48.944,0.059,0.007,0.043,824.404,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-04",6,5.24,206.82,,0.001,0.001,125.39,0.059,0.011,0.0148,2111.782,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-05",6,4.82,123.14,,0,0.001,84.522,0.0593,0.011,0.0345,1423.54,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-06",5,3.65,83.08,,0,0.001,59.875,0.059,0.009,0.046,1008.925,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-07",4,2.39,47.07,,0,0.001,35.771,0.0593,0.008,0.0695,600.899,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-08",2,0.1,0,,0,0.001,0.656,0.059,0.002,0.2785,11.052,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-13",2,1.1,42.94,,0,0.001,26.503,0.059,0.012,0.0715,446.369,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-15",7,5.44,148.88,,0.001,0.001,99.78,0.0591,0.011,0.0386,1679.32,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-16",5,3.44,69.92,,0,0.001,51.744,0.0594,0.009,0.0544,870.668,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-17",5,3.47,73.78,,0,0.001,53.348,0.0594,0.008,0.049,898.541,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-18",6,4.22,88.28,,0,0.001,65.358,0.0595,0.01,0.0563,1098.576,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-19",4,2.67,54.99,,0,0.001,41.042,0.0593,0.009,0.0438,690.762,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-20",5,3.4,67.15,,0,0.001,50.336,0.0592,0.014,0.049,847.309,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-21",3,2.27,45.13,,0,0.001,33.935,0.0593,0.009,0.0453,571.273,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-22",4,3.3,66.76,,0,0.001,49.606,0.0593,0.008,0.0235,833.86,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-23",3,2.05,39.84,,0,0.001,30.28,0.059,0.007,0.035,510.043,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-24",4,3.33,84.14,,0,0.001,58.006,0.0593,0.009,0.0203,977.582,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-29",3,1.59,32.64,,0,0.001,24.449,0.0593,0.007,0.0753,411.472,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-11-30",5,4.4,166.8,,0.001,0.001,102.28,0.059,0.013,0.0192,1722.62,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-01",8,5.97,204.71,,0.001,0.001,128.625,0.0593,0.019,0.0296,2165.034,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-02",5,4.37,171.4,,0.001,0.001,104.375,0.059,0.014,0.02,1757.184,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-03",7,5.82,201.47,,0.001,0.001,126.781,0.0593,0.014,0.0259,2134.175,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-04",10,8.5,351.82,,0.001,0.001,213.385,0.0591,0.032,0.0311,3591.946,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-05",6,5.31,231.89,,0.001,0.001,138.864,0.059,0.017,0.0187,2338.079,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-07",5,4.42,172.26,,0.001,0.001,105.948,0.0594,0.013,0.0202,1782.206,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-08",4,2.31,43.12,,0,0.001,33.512,0.0595,0.015,0.0613,563.615,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-09",6,4.88,134.92,,0,0.001,91.482,0.0593,0.012,0.031,1540.114,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-10",7,5.51,186.85,,0.001,0.001,119.071,0.0593,0.019,0.0339,2003.046,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-11",7,6.42,279.34,,0.001,0.001,168.186,0.0591,0.02,0.017,2829.024,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-12",7,5.71,246.19,,0.001,0.001,146.582,0.0591,0.026,0.074,2466.368,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-13",7,5.44,112.52,,0,0.001,84.932,0.059,0.011,0.0437,1429.54,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-14",8,5.7,174.35,,0.001,0.001,114.848,0.0593,0.037,0.054,1932.536,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-15",9,7.47,285.71,,0.001,0.001,176.289,0.0592,0.027,0.0246,2966.175,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-18",3,1.16,35,,0,0.001,23.207,0.059,0.006,0.0617,390.818,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-19",3,1.63,39.95,,0,0.001,28.301,0.0593,0.012,0.0713,475.874,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-21",3,1.3,25.18,,0,0.001,19.454,0.0593,0.006,0.1003,327.384,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-23",3,2.3,46.76,,0,0.001,35.624,0.059,0.015,0.0593,599.996,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-27",5,4.6,103.1,,0,0.001,75.085,0.0592,0.018,0.0312,1262.483,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-28",2,1.55,60.75,,0,0.001,37.235,0.0595,0.005,0.0175,626.535,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverview Energy Center",55963,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-01",24,24,4896,,0.011,0.001,2082.3,0.059,0.083,0.0048,35036.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-02",24,24,5750,,0.012,0.001,2382.5,0.059,0.101,0.005,40087.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-03",24,24,5940,,0.012,0.001,2444.2,0.059,0.093,0.0045,41125.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-04",24,24,5337,,0.011,0.001,2242.7,0.059,0.075,0.004,37739,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-05",1,0.08,0.08,,0,0.001,0.52,0.059,0.001,0.131,8.776,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-06",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-07",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-08",10,9.97,1955.55,,0.004,0.001,873.602,0.059,0.143,0.036,14701.648,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-09",24,24,5875,,0.012,0.001,2431.1,0.059,0.104,0.005,40910,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-10",24,24,6295,,0.013,0.001,2580.4,0.059,0.1,0.0046,43420.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-11",24,24,4929,,0.011,0.001,2094.1,0.059,0.084,0.0048,35238.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-12",24,24,5731,,0.012,0.001,2375.7,0.059,0.087,0.0044,39977.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-13",24,24,5757,,0.012,0.001,2389.3,0.059,0.091,0.0045,40205.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-14",24,24,5767,,0.012,0.001,2383.7,0.059,0.086,0.0043,40110,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-15",24,24,5999,,0.012,0.001,2473.3,0.059,0.096,0.0046,41617.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-16",24,24,6299,,0.013,0.001,2577.3,0.059,0.089,0.0041,43367.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-17",24,24,6181,,0.013,0.001,2542,0.059,0.096,0.0045,42778.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-18",24,24,5719,,0.012,0.001,2375.5,0.059,0.098,0.0049,39973,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-19",24,24,6759,,0.014,0.001,2741.4,0.059,0.104,0.0045,46128.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-20",24,24,6607,,0.014,0.001,2680.6,0.059,0.102,0.0045,45108.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-21",24,24,5271,,0.011,0.001,2208.1,0.059,0.077,0.0042,37157,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-22",24,24,5251,,0.011,0.001,2214.8,0.059,0.069,0.0038,37267.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-23",24,24,6153,,0.013,0.001,2535.5,0.059,0.097,0.0045,42665.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-24",24,24,5496,,0.012,0.001,2299.3,0.059,0.089,0.0046,38687.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-25",24,24,5799,,0.012,0.001,2351.4,0.059,0.098,0.005,39569.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-26",24,24,5887,,0.012,0.001,2380.9,0.059,0.1,0.005,40061.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-27",24,24,5215,,0.011,0.001,2149,0.059,0.077,0.0043,36162,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-28",24,24,5553,,0.011,0.001,2265.9,0.059,0.085,0.0044,38128.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-29",24,24,6304,,0.013,0.001,2528.5,0.059,0.1,0.0046,42548,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-30",24,24,6108,,0.013,0.001,2479.6,0.059,0.108,0.0052,41725.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-01-31",24,24,5748,,0.012,0.001,2385.2,0.059,0.092,0.0046,40135.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-01",24,24,6181,,0.013,0.001,2526.1,0.059,0.088,0.0041,42546.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-02",24,24,6231,,0.013,0.001,2548.2,0.059,0.083,0.0039,42920.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-03",24,24,6425,,0.013,0.001,2626.5,0.059,0.103,0.0047,44241.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-04",24,24,6060,,0.013,0.001,2500.4,0.059,0.106,0.0051,42119.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-05",24,24,6285,,0.013,0.001,2577.6,0.059,0.098,0.0045,43409.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-06",24,24,5743,,0.012,0.001,2374.5,0.059,0.084,0.0042,39991.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-07",24,24,5782,,0.012,0.001,2395.2,0.059,0.086,0.0042,40342.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-08",24,24,5791,,0.012,0.001,2397.8,0.059,0.087,0.0043,40389.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-09",24,24,5479,,0.012,0.001,2282.3,0.059,0.091,0.0047,38434.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-10",24,24,5389,,0.011,0.001,2251.6,0.059,0.08,0.0042,37920.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-11",24,24,5610,,0.012,0.001,2337.7,0.059,0.088,0.0045,39375.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-12",24,24,5966,,0.012,0.001,2470.8,0.059,0.091,0.0043,41612.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-13",24,24,6085,,0.013,0.001,2510.1,0.059,0.098,0.0047,42282.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-14",24,24,6313,,0.013,0.001,2581.8,0.059,0.105,0.0048,43485.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-15",24,24,5732,,0.012,0.001,2361.6,0.059,0.093,0.0047,39779.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-16",24,24,5408,,0.011,0.001,2253.5,0.059,0.085,0.0045,37956.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-17",24,24,5533,,0.012,0.001,2292.2,0.059,0.091,0.0047,38613.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-18",24,24,5864,,0.012,0.001,2408.6,0.059,0.088,0.0044,40564.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-19",24,24,6323,,0.013,0.001,2591.6,0.059,0.098,0.0044,43655.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-20",24,24,5752,,0.012,0.001,2398.4,0.059,0.088,0.0043,40394.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-21",24,24,6616,,0.014,0.001,2693,0.059,0.112,0.005,45360.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-22",24,24,5191,,0.011,0.001,2186.3,0.059,0.09,0.0049,36824.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-23",24,24,5163,,0.011,0.001,2197.6,0.059,0.083,0.0045,37017,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-24",24,24,5859,,0.012,0.001,2435.3,0.059,0.082,0.004,41018.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-25",23,22.25,5016.5,,0.011,0.001,2210.35,0.059,0.083,0.006,37229.425,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-26",3,1.5,108.19,,0,0.001,70.686,0.059,0.046,0.082,1190.863,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-27",24,24,5479,,0.012,0.001,2279.1,0.059,0.094,0.0049,38384.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-28",24,24,5271,,0.011,0.001,2203.2,0.059,0.077,0.0042,37111.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-02-29",24,24,4931,,0.011,0.001,2085,0.059,0.075,0.0043,35117,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-01",24,24,6400,,0.013,0.001,2607.7,0.059,0.091,0.0041,43922.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-02",24,24,5610,,0.012,0.001,2328.5,0.059,0.093,0.0048,39219.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-03",24,24,5686,,0.012,0.001,2355.4,0.059,0.094,0.0048,39669.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-04",24,24,5744,,0.012,0.001,2373.9,0.059,0.087,0.0044,39988.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-05",24,24,5843,,0.012,0.001,2411.1,0.059,0.085,0.0043,40610.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-06",24,24,6093,,0.013,0.001,2497.9,0.059,0.086,0.0041,42074.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-07",24,24,6218,,0.013,0.001,2543.4,0.059,0.09,0.0042,42836.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-08",24,24,6316,,0.013,0.001,2580.7,0.059,0.091,0.0041,43468.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-09",24,24,6384,,0.013,0.001,2608.2,0.059,0.1,0.0045,43930,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-10",24,24,6516,,0.013,0.001,2661.1,0.059,0.097,0.0043,44816,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-11",24,24,6869,,0.014,0.001,2774.7,0.059,0.113,0.0048,46735.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-12",24,24,7025,,0.014,0.001,2824.2,0.059,0.113,0.0048,47567.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-13",24,24,6512,,0.013,0.001,2646,0.059,0.106,0.0047,44566,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-14",24,24,6612,,0.014,0.001,2689.9,0.059,0.101,0.0044,45308.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-15",24,24,6534,,0.013,0.001,2662.8,0.059,0.109,0.0048,44849.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-16",24,24,7093,,0.014,0.001,2830.7,0.059,0.11,0.0046,47675.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-17",24,24,6206,,0.013,0.001,2490.5,0.059,0.092,0.0044,41949.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-18",24,24,6111,,0.012,0.001,2456.4,0.059,0.081,0.0039,41371.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-19",24,24,5990,,0.012,0.001,2428.7,0.059,0.084,0.0041,40908.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-20",24,24,5587,,0.011,0.001,2267,0.059,0.083,0.0044,38184.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-21",24,24,5958,,0.012,0.001,2393.8,0.059,0.083,0.0042,40320.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-22",24,24,6018,,0.012,0.001,2414.4,0.059,0.086,0.0043,40666.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-23",24,24,5688,,0.012,0.001,2303.5,0.059,0.084,0.0043,38797.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-24",24,24,5937,,0.012,0.001,2393.1,0.059,0.09,0.0045,40303.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-25",24,24,5363,,0.011,0.001,2198,0.059,0.077,0.0041,37023,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-26",24,24,5261,,0.011,0.001,2184.7,0.059,0.081,0.0044,36799.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-27",1,0.08,0,,0,0.001,0.296,0.059,0,0.134,5.024,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-28",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-29",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-30",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-03-31",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-01",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-02",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-03",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-04",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-05",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-06",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-07",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-08",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-09",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-10",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-11",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-12",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-13",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-14",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-15",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-16",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-17",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-18",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-19",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-20",6,4.27,184.06,,0.001,0.001,200.044,0.0592,0.191,0.1155,3364.96,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-21",5,4.53,622.3,,0.002,0.001,338.126,0.059,0.039,0.034,5689.304,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-22",24,24,5662,,0.012,0.001,2353.5,0.059,0.085,0.0043,39600.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-23",24,24,4953,,0.01,0.001,2057.8,0.059,0.099,0.0057,34625.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-24",24,24,5418,,0.011,0.001,2217.9,0.059,0.105,0.0057,37323.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-25",24,24,5889,,0.012,0.001,2386.1,0.059,0.103,0.0051,40150.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-26",24,24,4792,,0.01,0.001,2012.2,0.059,0.076,0.0044,33862.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-27",24,24,4613,,0.01,0.001,1951.2,0.059,0.068,0.0042,32834.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-28",24,24,5371,,0.011,0.001,2210.7,0.059,0.078,0.0042,37200.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-29",24,24,4806,,0.01,0.001,2013.3,0.059,0.076,0.0045,33874.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-04-30",24,24,4263,,0.009,0.001,1831.5,0.059,0.068,0.0044,30815.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-01",24,24,5175,,0.011,0.001,2123,0.059,0.08,0.0043,36139.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-02",24,24,4701,,0.01,0.001,1958.4,0.059,0.08,0.0048,33339.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-03",24,24,4734,,0.01,0.001,1966.6,0.059,0.072,0.0043,33481.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-04",24,24,5453,,0.011,0.001,2217.5,0.059,0.076,0.004,37746.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-05",24,24,5149,,0.011,0.001,2125.7,0.059,0.069,0.0038,36181.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-06",24,24,5687,,0.012,0.001,2353.1,0.059,0.086,0.0043,40056.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-07",24,24,5881,,0.012,0.001,2415.7,0.059,0.093,0.0045,41122.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-08",24,24,5522,,0.012,0.001,2277.8,0.059,0.092,0.0048,38778.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-09",24,24,5401,,0.011,0.001,2238.4,0.059,0.093,0.0049,38102.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-10",24,24,4794,,0.01,0.001,2028.1,0.059,0.086,0.005,34524.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-11",24,24,5612,,0.012,0.001,2327,0.059,0.086,0.0044,39615.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-12",24,24,5821,,0.012,0.001,2388.4,0.059,0.085,0.0042,40659.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-13",24,24,5146,,0.011,0.001,2156.2,0.059,0.085,0.0046,36705,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-14",24,24,5894,,0.012,0.001,2413.1,0.059,0.087,0.0043,41081.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-15",24,24,5040,,0.011,0.001,2111,0.059,0.084,0.0047,35937.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-16",24,24,5551,,0.012,0.001,2297.7,0.059,0.084,0.0043,39113,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-17",24,24,5059,,0.011,0.001,2127.9,0.059,0.075,0.0042,36222.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-18",24,24,4169,,0.009,0.001,1825.7,0.059,0.074,0.0048,31077.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-19",24,24,4454,,0.01,0.001,1934.8,0.059,0.074,0.0045,32935,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-20",24,24,4448,,0.01,0.001,1989.3,0.059,0.087,0.0052,33864.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-21",24,24,4992,,0.011,0.001,2210.7,0.059,0.093,0.005,37633.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-22",15,14.9,2690,,0.006,0.001,1231.33,0.059,0.055,0.0053,20962.22,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-23",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-24",13,12.08,2312.08,,0.005,0.001,1025.164,0.059,0.148,0.0302,17453.548,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-25",24,24,5405,,0.011,0.001,2245.7,0.059,0.087,0.0046,38229.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-26",24,24,5751,,0.012,0.001,2353.9,0.059,0.095,0.0047,40072,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-27",24,24,5889,,0.012,0.001,2411.1,0.059,0.097,0.0048,41047.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-28",24,24,5057,,0.011,0.001,2083.7,0.059,0.081,0.0046,35475.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-29",24,24,5327,,0.011,0.001,2185.1,0.059,0.065,0.0035,37199.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-30",24,24,4827,,0.01,0.001,1997.2,0.059,0.067,0.004,33998.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-05-31",24,24,4514,,0.01,0.001,1887.1,0.059,0.073,0.0045,32128.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-01",24,24,5583,,0.011,0.001,2267.7,0.059,0.086,0.0045,38312.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-02",24,24,5585,,0.012,0.001,2294.2,0.059,0.081,0.0043,38756.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-03",24,24,6334,,0.013,0.001,2543.2,0.059,0.075,0.0035,42958,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-04",24,24,6122,,0.012,0.001,2462.6,0.059,0.084,0.004,41595.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-05",24,24,5416,,0.011,0.001,2215.4,0.059,0.087,0.0047,37426.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-06",24,24,4673,,0.01,0.001,1966.6,0.059,0.082,0.005,33223.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-07",24,24,5077,,0.011,0.001,2116.1,0.059,0.086,0.0049,35742.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-08",24,24,5469,,0.011,0.001,2242.5,0.059,0.089,0.0047,37877.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-09",24,24,5880,,0.012,0.001,2389,0.059,0.093,0.0046,40358.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-10",24,24,6016,,0.012,0.001,2439.7,0.059,0.091,0.0044,41211.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-11",24,24,5761,,0.012,0.001,2351.9,0.059,0.093,0.0046,39730.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-12",24,24,5643,,0.012,0.001,2304.7,0.059,0.089,0.0046,38935.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-13",24,24,5153,,0.011,0.001,2139.9,0.059,0.091,0.005,36147.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-14",24,24,4986,,0.011,0.001,2078.5,0.059,0.085,0.0049,35108.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-15",24,24,5095,,0.011,0.001,2114.1,0.059,0.08,0.0045,35714,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-16",24,24,5579,,0.012,0.001,2286.4,0.059,0.093,0.0048,38621.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-17",24,24,5051,,0.011,0.001,2097.2,0.059,0.079,0.0044,35425.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-18",24,24,5356,,0.011,0.001,2201.3,0.059,0.084,0.0045,37185.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-19",24,24,5891,,0.012,0.001,2373.2,0.059,0.087,0.0044,40084.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-20",24,24,5143,,0.011,0.001,2126.4,0.059,0.075,0.0042,35920.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-21",24,24,4978,,0.01,0.001,2068.6,0.059,0.073,0.0042,34943.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-22",24,24,5715,,0.012,0.001,2328.7,0.059,0.086,0.0044,39334.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-23",24,24,6835,,0.014,0.001,2723.3,0.059,0.105,0.0045,46000.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-24",24,24,5944,,0.012,0.001,2417.5,0.059,0.095,0.0046,40837.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-25",24,24,5830,,0.012,0.001,2376.3,0.059,0.088,0.0044,40140.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-26",24,24,6452,,0.013,0.001,2590.3,0.059,0.093,0.0043,43754.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-27",24,24,5897,,0.012,0.001,2388.6,0.059,0.084,0.0042,40350.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-28",24,24,5417,,0.011,0.001,2215.6,0.059,0.085,0.0045,37423.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-29",24,24,5226,,0.011,0.001,2149.1,0.059,0.086,0.0048,36298.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-06-30",24,24,5162,,0.011,0.001,2131.7,0.059,0.093,0.0052,36009.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-01",24,24,5718,,0.012,0.001,2322.1,0.059,0.089,0.0045,39183.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-02",24,24,5096,,0.011,0.001,2112.7,0.059,0.079,0.0045,35657.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-03",24,24,5714,,0.012,0.001,2328.8,0.059,0.089,0.0045,39302.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-04",24,24,6085,,0.012,0.001,2454.4,0.059,0.094,0.0045,41421,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-05",24,24,5921,,0.012,0.001,2415,0.059,0.105,0.0052,40750.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-06",24,24,4898,,0.011,0.001,2082,0.059,0.184,0.0112,35126.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-07",24,24,5136,,0.011,0.001,2172.1,0.059,0.089,0.005,36649.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-08",24,24,5507,,0.011,0.001,2220.6,0.059,0.091,0.0049,37477.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-09",24,24,5425,,0.011,0.001,2197.8,0.059,0.09,0.0049,37088.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-10",24,24,5707,,0.012,0.001,2320.2,0.059,0.083,0.0043,39155,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-11",24,24,6384,,0.013,0.001,2556.9,0.059,0.103,0.0048,43150.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-12",24,24,5641,,0.012,0.001,2295.3,0.059,0.082,0.0043,38733,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-13",24,24,5180,,0.011,0.001,2129.7,0.059,0.077,0.0043,35940.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-14",24,24,5033,,0.011,0.001,2084.6,0.059,0.082,0.0047,35179.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-15",24,24,4885,,0.01,0.001,2029.9,0.059,0.077,0.0045,34256.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-16",24,24,4549,,0.01,0.001,1908.4,0.059,0.081,0.005,32209.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-17",24,24,5392,,0.011,0.001,2215.5,0.059,0.085,0.0046,37388,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-18",24,24,5743,,0.012,0.001,2332.4,0.059,0.083,0.0043,39361.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-19",24,24,4969,,0.01,0.001,2057,0.059,0.07,0.004,34718.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-20",24,24,5048,,0.011,0.001,2091.4,0.059,0.077,0.0044,35294.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-21",24,24,5577,,0.011,0.001,2270.4,0.059,0.084,0.0044,38318.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-22",24,24,5481,,0.011,0.001,2236.7,0.059,0.086,0.0046,37745.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-23",24,24,5277,,0.011,0.001,2159.8,0.059,0.081,0.0045,36452.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-24",24,24,5588,,0.012,0.001,2271.4,0.059,0.084,0.0044,38333.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-25",24,24,6136,,0.012,0.001,2463.2,0.059,0.087,0.0042,41569.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-26",24,24,6190,,0.013,0.001,2482,0.059,0.084,0.004,41885.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-27",24,24,5816,,0.012,0.001,2351.6,0.059,0.083,0.0042,39684,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-28",24,24,5762,,0.012,0.001,2341.7,0.059,0.079,0.0041,39518.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-29",24,24,6032,,0.012,0.001,2430.1,0.059,0.082,0.004,41009.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-30",24,24,6008,,0.012,0.001,2423.9,0.059,0.081,0.004,40904.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-07-31",24,24,5837,,0.012,0.001,2353.4,0.059,0.093,0.0047,39711.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-01",24,24,5134,,0.011,0.001,2115.1,0.059,0.094,0.0053,35689.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-02",24,24,5363,,0.011,0.001,2203.2,0.059,0.091,0.0049,37181.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-03",24,24,5207,,0.011,0.001,2147.4,0.059,0.09,0.005,36237.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-04",24,24,5340,,0.011,0.001,2197.8,0.059,0.081,0.0044,37088.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-05",24,24,5043,,0.011,0.001,2096.7,0.059,0.077,0.0044,35385.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-06",24,24,4742,,0.01,0.001,1985.5,0.059,0.081,0.0049,33509.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-07",24,24,5314,,0.011,0.001,2190.1,0.059,0.09,0.0049,36965.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-08",24,24,5480,,0.011,0.001,2244.4,0.059,0.086,0.0046,37877.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-09",24,24,5665,,0.012,0.001,2314.2,0.059,0.095,0.0049,39052,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-10",24,24,5801,,0.012,0.001,2354.5,0.059,0.086,0.0044,39732.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-11",24,24,5036,,0.011,0.001,2090.3,0.059,0.083,0.0047,35272.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-12",24,24,5960,,0.012,0.001,2416.3,0.059,0.095,0.0047,40772.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-13",24,24,6704,,0.014,0.001,2676.1,0.059,0.1,0.0045,45164,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-14",24,24,6542,,0.013,0.001,2619.2,0.059,0.103,0.0047,44200.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-15",24,24,6630,,0.013,0.001,2649.9,0.059,0.105,0.0047,44718.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-16",24,24,6389,,0.013,0.001,2568.1,0.059,0.083,0.0039,43339,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-17",24,24,6612,,0.013,0.001,2653.6,0.059,0.089,0.004,44783.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-18",24,24,6683,,0.013,0.001,2655.6,0.059,0.106,0.0048,44814.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-19",24,24,6004,,0.012,0.001,2407.6,0.059,0.094,0.0046,40630.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-20",24,24,4699,,0.01,0.001,1964.3,0.059,0.08,0.0049,33146.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-21",24,24,6205,,0.013,0.001,2495.1,0.059,0.083,0.004,42106.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-22",24,24,6314,,0.013,0.001,2538.3,0.059,0.092,0.0043,42834.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-23",24,24,6123,,0.013,0.001,2468.5,0.059,0.093,0.0045,41661.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-24",24,24,6758,,0.014,0.001,2692.5,0.059,0.11,0.0048,45438.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-25",24,24,5870,,0.012,0.001,2378.4,0.059,0.089,0.0045,40139.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-26",24,24,5357,,0.011,0.001,2190.8,0.059,0.078,0.0043,36974.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-27",24,24,4923,,0.01,0.001,2045.5,0.059,0.082,0.0048,34521.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-28",24,24,5476,,0.011,0.001,2237.4,0.059,0.088,0.0047,37756.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-29",24,24,5002,,0.01,0.001,2073.8,0.059,0.094,0.0054,34997.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-30",24,24,4694,,0.01,0.001,1964.5,0.059,0.093,0.0057,33152.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-08-31",24,24,4977,,0.01,0.001,2067.2,0.059,0.095,0.0055,34885.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-01",24,24,5127,,0.011,0.001,2113.1,0.059,0.08,0.0045,35662,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-02",24,24,4922,,0.01,0.001,2045.8,0.059,0.078,0.0046,34522.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-03",24,24,5829,,0.012,0.001,2373,0.059,0.086,0.0044,40045.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-04",24,24,6310,,0.013,0.001,2535,0.059,0.096,0.0045,42782.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-05",24,24,5637,,0.012,0.001,2295.5,0.059,0.101,0.0053,38742.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-06",24,24,5858,,0.012,0.001,2376.6,0.059,0.099,0.0049,40112.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-07",24,24,6461,,0.013,0.001,2584.1,0.059,0.104,0.0048,43609.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-08",24,24,5558,,0.011,0.001,2261.2,0.059,0.091,0.0048,38160.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-09",24,24,5086,,0.011,0.001,2089.7,0.059,0.091,0.0053,35263.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-10",24,24,5506,,0.011,0.001,2246.2,0.059,0.095,0.005,37908.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-11",24,24,5792,,0.012,0.001,2344.1,0.059,0.085,0.0043,39557.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-12",24,24,5796,,0.012,0.001,2349,0.059,0.087,0.0045,39641.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-13",24,24,5788,,0.012,0.001,2347.9,0.059,0.087,0.0044,39617.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-14",24,24,5767,,0.012,0.001,2341.4,0.059,0.098,0.005,39516.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-15",24,24,6310,,0.013,0.001,2526.2,0.059,0.095,0.0045,42631.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-16",24,24,6147,,0.012,0.001,2464.2,0.059,0.095,0.0046,41585.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-17",24,24,6511,,0.013,0.001,2586.7,0.059,0.091,0.0042,43655.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-18",24,24,6192,,0.012,0.001,2465.8,0.059,0.089,0.0043,41606.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-19",24,24,5584,,0.011,0.001,2269.2,0.059,0.084,0.0045,38295.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-20",24,24,5658,,0.012,0.001,2286.6,0.059,0.088,0.0047,38587.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-21",24,24,5865,,0.012,0.001,2365.2,0.059,0.086,0.0043,39910.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-22",24,24,5908,,0.012,0.001,2373.4,0.059,0.079,0.004,40052.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-23",24,24,5340,,0.011,0.001,2175.9,0.059,0.081,0.0045,36727.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-24",24,24,5485,,0.011,0.001,2232.4,0.059,0.075,0.004,37671.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-25",24,24,4957,,0.01,0.001,2047.9,0.059,0.08,0.0047,34561.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-26",24,24,4786,,0.01,0.001,1995.2,0.059,0.069,0.004,33675,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-27",24,24,5011,,0.01,0.001,2065.8,0.059,0.08,0.0046,34864.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-28",24,24,5170,,0.011,0.001,2128.9,0.059,0.086,0.0049,35926,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-29",24,24,5456,,0.011,0.001,2222.4,0.059,0.08,0.0043,37503.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-09-30",24,24,6205,,0.013,0.001,2482.2,0.059,0.086,0.0042,41885,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-01",24,24,5977,,0.012,0.001,2404.5,0.059,0.088,0.0044,40616.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-02",24,24,5769,,0.012,0.001,2334.3,0.059,0.086,0.0045,39431.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-03",24,24,5951,,0.013,0.001,2469.1,0.059,0.103,0.005,41708.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-04",24,24,5927,,0.013,0.001,2475.7,0.059,0.095,0.0045,41813.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-05",24,24,6114,,0.013,0.001,2532.3,0.059,0.096,0.0045,42781,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-06",24,24,6687,,0.014,0.001,2719.6,0.059,0.107,0.0047,45938.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-07",24,24,6747,,0.013,0.001,2649.2,0.059,0.101,0.0045,44750.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-08",24,24,5398,,0.011,0.001,2178.2,0.059,0.082,0.0045,36790.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-09",24,24,5659,,0.012,0.001,2277,0.059,0.086,0.0045,38461.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-10",24,24,5417,,0.011,0.001,2194.3,0.059,0.082,0.0045,37065.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-11",24,24,4693,,0.01,0.001,1941.6,0.059,0.086,0.0053,32797.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-12",24,24,5261,,0.011,0.001,2137.8,0.059,0.08,0.0045,36110.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-13",24,24,5859,,0.012,0.001,2330,0.059,0.079,0.004,39357.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-14",24,24,6137,,0.012,0.001,2410.2,0.059,0.08,0.004,40712.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-15",24,24,6727,,0.013,0.001,2620.6,0.059,0.089,0.004,44269.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-16",24,24,5841,,0.012,0.001,2339.4,0.059,0.083,0.0043,39520.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-17",24,24,5509,,0.011,0.001,2221,0.059,0.085,0.0047,37522.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-18",24,24,6441,,0.013,0.001,2552.6,0.059,0.094,0.0044,43118,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-19",24,24,6542,,0.013,0.001,2588.9,0.059,0.094,0.0044,43730.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-20",24,24,6306,,0.013,0.001,2507.8,0.059,0.088,0.0042,42362,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-21",24,24,6524,,0.013,0.001,2583.3,0.059,0.09,0.0042,43638.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-22",24,24,6416,,0.013,0.001,2541.9,0.059,0.09,0.0043,42942.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-23",24,23.05,6061.05,,0.012,0.001,2408.055,0.059,0.089,0.009,40674.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-24",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-25",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-26",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-27",9,8.6,1894.6,,0.004,0.001,811.1,0.059,0.115,0.0433,13700.56,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-28",24,24,6421,,0.013,0.001,2550.9,0.059,0.092,0.0044,43090.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-29",24,24,6192,,0.013,0.001,2475.6,0.059,0.091,0.0044,41814.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-30",24,24,6313,,0.013,0.001,2518,0.059,0.102,0.0049,42533.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-10-31",24,24,5908,,0.012,0.001,2377.6,0.059,0.092,0.0047,40164.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-01",24,24,6161,,0.013,0.001,2499.4,0.059,0.093,0.0045,42224.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-02",24,24,6868,,0.014,0.001,2724.2,0.059,0.099,0.0043,46013.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-03",24,24,6907,,0.014,0.001,2734.7,0.059,0.108,0.0047,46193.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-04",24,24,6728,,0.014,0.001,2695.2,0.059,0.104,0.0045,45524.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-05",24,24,6993,,0.014,0.001,2785,0.059,0.114,0.0048,47045,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-06",24,24,5455,,0.011,0.001,2246.6,0.059,0.098,0.0053,37952,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-07",24,24,5048,,0.011,0.001,2110.7,0.059,0.093,0.0053,35657.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-08",24,24,5017,,0.011,0.001,2108.6,0.059,0.09,0.005,35623,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-09",24,24,5997,,0.012,0.001,2449.6,0.059,0.104,0.0051,41379,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-10",24,24,6159,,0.013,0.001,2511,0.059,0.096,0.0046,42414.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-11",24,24,6062,,0.013,0.001,2469.2,0.059,0.093,0.0045,41708.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-12",24,24,5705,,0.012,0.001,2347.2,0.059,0.09,0.0046,39650.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-13",24,24,6146,,0.013,0.001,2493.4,0.059,0.094,0.0045,42115.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-14",24,24,5144,,0.011,0.001,2148.5,0.059,0.086,0.0048,36290.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-15",24,24,5249,,0.011,0.001,2188.3,0.059,0.084,0.0046,36962.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-16",24,24,5654,,0.012,0.001,2318.5,0.059,0.086,0.0045,39163.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-17",24,24,6100,,0.012,0.001,2438,0.059,0.087,0.0043,41184.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-18",24,24,5741,,0.012,0.001,2318.8,0.059,0.084,0.0043,39175.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-19",24,24,5696,,0.012,0.001,2307,0.059,0.084,0.0043,38968.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-20",24,24,6384,,0.013,0.001,2609.3,0.059,0.091,0.0041,44078.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-21",6,5.08,1398.08,,0.003,0.001,571.988,0.059,0.021,0.0247,9664.832,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-22",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-23",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-24",20,19.07,4465,,0.01,0.001,1891.178,0.0591,0.183,0.0247,31946.342,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-25",24,24,6293,,0.013,0.001,2566.9,0.059,0.091,0.0042,43361.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-26",24,24,5770,,0.012,0.001,2383.5,0.059,0.082,0.0041,40262,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-27",24,24,5875,,0.012,0.001,2425.8,0.059,0.084,0.0041,40978.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-28",24,24,6344,,0.013,0.001,2591.8,0.059,0.101,0.0046,43778.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-29",24,24,6985,,0.014,0.001,2818.8,0.059,0.133,0.0056,47614.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-11-30",24,24,6453,,0.013,0.001,2629.6,0.059,0.13,0.0058,44422.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-01",24,24,7004,,0.014,0.001,2803.5,0.059,0.14,0.0059,47353.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-02",24,24,6696,,0.014,0.001,2684.9,0.059,0.134,0.0059,45353.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-03",24,24,6979,,0.014,0.001,2796.1,0.059,0.141,0.006,47233.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-04",24,24,6676,,0.014,0.001,2692.6,0.059,0.133,0.0059,45482,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-05",24,24,6579,,0.014,0.001,2666.2,0.059,0.131,0.0058,45037.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-06",24,24,6602,,0.014,0.001,2683.4,0.059,0.127,0.0055,45323.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-07",24,24,6745,,0.014,0.001,2734.8,0.059,0.135,0.0058,46192.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-08",24,24,6747,,0.014,0.001,2730.9,0.059,0.133,0.0058,46126.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-09",24,24,6372,,0.013,0.001,2599,0.059,0.129,0.0058,43899.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-10",24,24,6715,,0.014,0.001,2719,0.059,0.135,0.0058,45926.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-11",24,24,6707,,0.014,0.001,2716.2,0.059,0.135,0.0059,45881.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-12",24,24,6921,,0.014,0.001,2789.3,0.059,0.14,0.0059,47116.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-13",24,24,6989,,0.014,0.001,2812.7,0.059,0.141,0.0059,47512,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-14",24,24,7091,,0.014,0.001,2853.4,0.059,0.142,0.0059,48198.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-15",24,24,6948,,0.014,0.001,2805.6,0.059,0.138,0.0058,47395.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-16",24,24,7015,,0.014,0.001,2824.7,0.059,0.141,0.0059,47717.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-17",24,24,6307,,0.013,0.001,2570.9,0.059,0.128,0.0059,43425.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-18",24,24,5905,,0.012,0.001,2448.6,0.059,0.118,0.0057,41363.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-19",24,24,6180,,0.013,0.001,2540.4,0.059,0.125,0.0058,42911.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-20",24,24,5912,,0.012,0.001,2447,0.059,0.117,0.0056,41334.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-21",24,24,6794,,0.014,0.001,2751.9,0.059,0.128,0.0055,46485.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-22",24,24,6425,,0.013,0.001,2620.2,0.059,0.12,0.0054,44260,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-23",24,24,6587,,0.014,0.001,2685.9,0.059,0.132,0.0058,45372.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-24",24,24,7167,,0.015,0.001,2887.1,0.059,0.143,0.0059,48772.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-25",24,24,6319,,0.013,0.001,2571.8,0.059,0.122,0.0055,43443.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-26",24,24,5893,,0.012,0.001,2429.4,0.059,0.119,0.0058,41038.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-27",24,24,6808,,0.014,0.001,2754.9,0.059,0.139,0.006,46531.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-28",24,24,7100,,0.014,0.001,2858.1,0.059,0.137,0.0057,48277.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-29",24,24,6746,,0.014,0.001,2734.1,0.059,0.126,0.0054,46185.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-30",24,24,6312,,0.013,0.001,2578.3,0.059,0.126,0.0058,43550,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"2",,"2020-12-31",24,24,6213,,0.013,0.001,2528.1,0.059,0.125,0.0058,42704.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-01",24,24,4904,,0.011,0.001,2100,0.059,0.081,0.0046,35337.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-02",24,24,5736,,0.012,0.001,2396,0.059,0.098,0.0048,40319.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-03",24,24,5944,,0.012,0.001,2466.1,0.059,0.087,0.0042,41495.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-04",24,24,5346,,0.011,0.001,2261.4,0.059,0.075,0.004,38051.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-05",24,24,5622,,0.012,0.001,2449.5,0.059,0.088,0.0043,41215.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-06",24,24,5933,,0.013,0.001,2591.5,0.059,0.098,0.0045,43601.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-07",24,24,5784,,0.013,0.001,2531.6,0.059,0.1,0.0047,42597.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-08",24,24,5563,,0.012,0.001,2441.7,0.059,0.092,0.0045,41088.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-09",24,24,5872,,0.012,0.001,2450.8,0.059,0.097,0.0047,41241.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-10",24,24,6301,,0.013,0.001,2605.3,0.059,0.108,0.0049,43838.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-11",24,24,4926,,0.011,0.001,2111.1,0.059,0.084,0.0048,35523.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-12",24,24,5728,,0.012,0.001,2396.6,0.059,0.083,0.0041,40327.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-13",24,24,5756,,0.012,0.001,2409.8,0.059,0.089,0.0044,40549.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-14",24,24,5762,,0.012,0.001,2403.3,0.059,0.088,0.0044,40440,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-15",24,24,6000,,0.013,0.001,2495.5,0.059,0.099,0.0047,41994.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-16",24,24,6292,,0.013,0.001,2598.1,0.059,0.1,0.0046,43720.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-17",24,24,6175,,0.013,0.001,2562.6,0.059,0.1,0.0046,43124.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-18",24,24,5718,,0.012,0.001,2393.9,0.059,0.102,0.005,40280.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-19",24,24,6762,,0.014,0.001,2767.9,0.059,0.103,0.0043,46573.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-20",24,24,6605,,0.014,0.001,2704.4,0.059,0.105,0.0046,45503.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-21",24,24,5267,,0.011,0.001,2227.6,0.059,0.08,0.0043,37482,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-22",24,24,5249,,0.011,0.001,2232.3,0.059,0.069,0.0037,37560.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-23",24,24,6145,,0.013,0.001,2554.3,0.059,0.095,0.0044,42980.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-24",24,24,5488,,0.012,0.001,2315.4,0.059,0.089,0.0046,38960.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-25",24,24,5790,,0.012,0.001,2370.1,0.059,0.097,0.0049,39883.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-26",24,24,5882,,0.012,0.001,2400,0.059,0.091,0.0045,40385.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-27",24,24,5208,,0.011,0.001,2166.4,0.059,0.076,0.0042,36456.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-28",24,24,5551,,0.012,0.001,2283.8,0.059,0.078,0.004,38433.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-29",24,24,6300,,0.013,0.001,2547.6,0.059,0.104,0.0048,42867.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-30",24,24,6102,,0.013,0.001,2499.2,0.059,0.098,0.0046,42053.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-01-31",24,24,5744,,0.012,0.001,2405.2,0.059,0.099,0.0049,40469.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-01",24,24,6174,,0.013,0.001,2546,0.059,0.093,0.0043,42885.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-02",24,24,6218,,0.013,0.001,2566.4,0.059,0.085,0.0039,43226.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-03",24,24,6433,,0.013,0.001,2651.8,0.059,0.102,0.0046,44662.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-04",24,24,6066,,0.013,0.001,2524.4,0.059,0.098,0.0046,42520.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-05",24,24,6285,,0.013,0.001,2601.2,0.059,0.091,0.0042,43811.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-06",24,24,5742,,0.012,0.001,2395.4,0.059,0.084,0.0041,40344.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-07",24,24,5782,,0.012,0.001,2415.7,0.059,0.09,0.0044,40686.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-08",24,24,5785,,0.012,0.001,2415.9,0.059,0.088,0.0043,40687.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-09",24,24,5472,,0.012,0.001,2299.3,0.059,0.087,0.0045,38723.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-10",24,24,5382,,0.011,0.001,2267.9,0.059,0.082,0.0043,38197.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-11",24,24,5594,,0.012,0.001,2353.9,0.059,0.085,0.0043,39649.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-12",24,24,5961,,0.013,0.001,2489.4,0.059,0.087,0.0041,41928.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-13",24,24,6082,,0.013,0.001,2530.5,0.059,0.099,0.0047,42620,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-14",24,24,6303,,0.013,0.001,2601.2,0.059,0.107,0.0049,43814.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-15",24,24,5727,,0.012,0.001,2380.7,0.059,0.093,0.0046,40098.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-16",24,24,5403,,0.011,0.001,2270.4,0.059,0.086,0.0045,38238.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-17",24,24,5525,,0.012,0.001,2308.8,0.059,0.089,0.0045,38888.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-18",24,24,5858,,0.012,0.001,2427.3,0.059,0.089,0.0044,40881.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-19",24,24,6323,,0.013,0.001,2613.5,0.059,0.096,0.0043,44019.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-20",24,24,5749,,0.012,0.001,2417.6,0.059,0.084,0.0041,40716.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-21",24,24,6611,,0.014,0.001,2713.3,0.059,0.112,0.0049,45701.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-22",24,24,5179,,0.011,0.001,2201.4,0.059,0.085,0.0046,37081.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-23",24,24,5153,,0.011,0.001,2214.1,0.059,0.079,0.0043,37290.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-24",24,24,5846,,0.012,0.001,2451.9,0.059,0.083,0.004,41295.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-25",23,22.23,5002,,0.011,0.001,2227.045,0.059,0.086,0.0083,37507.952,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-26",13,12.52,1678,,0.005,0.001,979.844,0.059,0.139,0.0363,16500.556,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-27",24,24,5456,,0.012,0.001,2290.6,0.059,0.092,0.0047,38582.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-28",24,24,5264,,0.011,0.001,2219,0.059,0.079,0.0042,37374,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-02-29",24,24,4925,,0.011,0.001,2102,0.059,0.071,0.004,35403.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-01",24,24,6384,,0.013,0.001,2625,0.059,0.083,0.0038,44210.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-02",24,24,5600,,0.012,0.001,2344,0.059,0.091,0.0046,39479.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-03",24,24,5684,,0.012,0.001,2375.7,0.059,0.093,0.0047,40016,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-04",24,24,5727,,0.012,0.001,2390.2,0.059,0.087,0.0044,40262.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-05",24,24,5831,,0.012,0.001,2425.9,0.059,0.088,0.0044,40857.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-06",24,24,6036,,0.013,0.001,2497.2,0.059,0.085,0.004,42061.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-07",24,24,6195,,0.013,0.001,2556.6,0.059,0.089,0.0041,43060.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-08",24,24,6290,,0.013,0.001,2591.9,0.059,0.094,0.0043,43659.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-09",24,24,6352,,0.013,0.001,2618.6,0.059,0.102,0.0046,44103.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-10",24,24,6494,,0.014,0.001,2675.1,0.059,0.103,0.0045,45057.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-11",24,24,6825,,0.014,0.001,2781.2,0.059,0.105,0.0045,46845.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-12",24,24,6873,,0.014,0.001,2790.4,0.059,0.116,0.0049,47000.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-13",24,24,6494,,0.013,0.001,2663.3,0.059,0.106,0.0047,44858.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-14",24,24,6596,,0.014,0.001,2708.1,0.059,0.1,0.0043,45616.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-15",24,24,6525,,0.014,0.001,2684.1,0.059,0.102,0.0045,45209.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-16",24,24,7089,,0.014,0.001,2855.8,0.059,0.11,0.0045,48097.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-17",24,24,6200,,0.013,0.001,2511,0.059,0.096,0.0045,42291.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-18",24,24,6098,,0.012,0.001,2471.7,0.059,0.083,0.004,41629.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-19",21,20.55,4798.7,,0.01,0.001,1983.97,0.059,0.096,0.0077,33416.71,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-20",24,24,5582,,0.012,0.001,2284,0.059,0.081,0.0043,38466.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-21",24,24,5952,,0.012,0.001,2411.8,0.059,0.082,0.004,40621.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-22",24,24,6010,,0.012,0.001,2430.4,0.059,0.089,0.0044,40931.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-23",24,24,5683,,0.012,0.001,2321.8,0.059,0.084,0.0043,39107.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-24",24,24,5932,,0.012,0.001,2409.8,0.059,0.085,0.0042,40587,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-25",24,24,5357,,0.011,0.001,2210.1,0.059,0.074,0.0039,37226.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-26",23,22.03,4855.03,,0.01,0.001,2013.012,0.0593,0.072,0.0077,33901.986,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-27",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-28",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-29",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-30",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-03-31",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-01",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-02",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-03",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-04",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-05",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-06",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-07",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-08",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-09",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-10",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-11",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-12",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-13",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-14",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-15",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-16",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-17",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-18",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-19",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-20",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-21",18,16.12,1358.84,,0.005,0.001,1047.534,0.0591,0.137,0.0261,17625.076,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-22",15,14.12,2832.12,,0.006,0.001,1218.684,0.059,0.135,0.0229,20507.848,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-23",24,24,4937,,0.01,0.001,2066.2,0.059,0.079,0.0045,34772.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-24",24,24,5407,,0.011,0.001,2230.1,0.059,0.083,0.0044,37528,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-25",24,24,5882,,0.012,0.001,2403.5,0.059,0.081,0.004,40443.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-26",24,24,4790,,0.01,0.001,2030.1,0.059,0.074,0.0043,34155.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-27",24,24,4604,,0.01,0.001,1962.8,0.059,0.062,0.0037,33029.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-28",24,24,5361,,0.011,0.001,2226.5,0.059,0.075,0.0039,37465.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-29",24,24,4801,,0.01,0.001,2026.2,0.059,0.068,0.004,34096.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-04-30",24,24,4258,,0.009,0.001,1846,0.059,0.059,0.0038,31063.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-01",24,24,5169,,0.011,0.001,2137.9,0.059,0.075,0.0041,36395.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-02",24,24,4690,,0.01,0.001,1969.7,0.059,0.07,0.0042,33527.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-03",24,24,4726,,0.01,0.001,1976.8,0.059,0.06,0.0035,33650.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-04",24,24,5446,,0.011,0.001,2229.4,0.059,0.08,0.0041,37952.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-05",24,24,5140,,0.011,0.001,2140.7,0.059,0.07,0.0038,36438.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-06",24,24,5673,,0.012,0.001,2365.2,0.059,0.091,0.0044,40258.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-07",24,24,5874,,0.012,0.001,2430,0.059,0.092,0.0044,41366.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-08",24,24,5513,,0.012,0.001,2290.8,0.059,0.081,0.0041,38998,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-09",24,24,5392,,0.012,0.001,2252,0.059,0.085,0.0043,38336.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-10",24,24,4782,,0.01,0.001,2035.8,0.059,0.075,0.0043,34656.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-11",24,24,5593,,0.012,0.001,2335.8,0.059,0.087,0.0044,39763,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-12",24,24,5805,,0.012,0.001,2398.2,0.059,0.084,0.0041,40824.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-13",24,24,5128,,0.011,0.001,2162.8,0.059,0.082,0.0044,36814.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-14",24,24,5880,,0.012,0.001,2421.3,0.059,0.089,0.0043,41215.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-15",24,24,5023,,0.011,0.001,2114.3,0.059,0.072,0.004,35989.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-16",24,24,5534,,0.012,0.001,2304.9,0.059,0.078,0.004,39238.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-17",24,24,5041,,0.011,0.001,2132.2,0.059,0.063,0.0035,36297.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-18",24,24,4153,,0.009,0.001,1825.7,0.059,0.062,0.004,31074.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-19",23,22.03,3998.03,,0.009,0.001,1746.812,0.0593,0.063,0.0087,29738.78,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-20",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-21",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-22",12,11.72,2374.92,,0.005,0.001,1073.264,0.059,0.108,0.0308,18270.608,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-23",24,24,4861,,0.011,0.001,2152,0.059,0.07,0.0037,36635.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-24",24,24,4712,,0.011,0.001,2100.2,0.059,0.057,0.0032,35753.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-25",24,24,5383,,0.011,0.001,2246.4,0.059,0.072,0.0037,38242.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-26",24,24,5727,,0.012,0.001,2357.1,0.059,0.093,0.0045,40123.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-27",24,24,5863,,0.012,0.001,2414.8,0.059,0.092,0.0044,41112,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-28",24,24,5042,,0.011,0.001,2090.5,0.059,0.071,0.0039,35583.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-29",24,24,5310,,0.011,0.001,2188.1,0.059,0.071,0.0038,37247.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-30",24,24,4807,,0.01,0.001,1997.5,0.059,0.068,0.004,34003.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-05-31",24,24,4493,,0.01,0.001,1884.4,0.059,0.071,0.0044,32081.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-01",24,24,5556,,0.011,0.001,2267.5,0.059,0.082,0.0043,38300.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-02",24,24,5559,,0.012,0.001,2292.8,0.059,0.081,0.0043,38727.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-03",24,24,6310,,0.013,0.001,2544,0.059,0.086,0.004,42971.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-04",24,24,6095,,0.012,0.001,2459.9,0.059,0.083,0.004,41550.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-05",24,24,5392,,0.011,0.001,2211.2,0.059,0.081,0.0044,37352.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-06",24,24,4646,,0.01,0.001,1958.6,0.059,0.076,0.0046,33080.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-07",24,24,5050,,0.011,0.001,2107.3,0.059,0.084,0.0047,35598.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-08",24,24,5441,,0.011,0.001,2236.1,0.059,0.085,0.0044,37772.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-09",24,24,5853,,0.012,0.001,2383.4,0.059,0.088,0.0044,40264.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-10",24,24,5986,,0.012,0.001,2431.7,0.059,0.093,0.0045,41074.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-11",24,24,5734,,0.012,0.001,2343.3,0.059,0.095,0.0048,39580,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-12",24,24,5616,,0.012,0.001,2297.9,0.059,0.086,0.0044,38816.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-13",24,24,5126,,0.011,0.001,2128.3,0.059,0.081,0.0045,35950.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-14",24,24,4953,,0.01,0.001,2063.6,0.059,0.073,0.0042,34859.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-15",24,24,5056,,0.011,0.001,2099.5,0.059,0.075,0.0043,35464.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-16",24,24,5548,,0.012,0.001,2276.2,0.059,0.085,0.0044,38447.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-17",24,24,5004,,0.01,0.001,2070.7,0.059,0.078,0.0044,34974.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-18",24,24,5322,,0.011,0.001,2185.9,0.059,0.081,0.0043,36928.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-19",24,24,5851,,0.012,0.001,2357.4,0.059,0.085,0.0043,39820.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-20",24,24,5100,,0.011,0.001,2100.3,0.059,0.065,0.0037,35479.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-21",24,24,4931,,0.01,0.001,2039.8,0.059,0.069,0.004,34457.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-22",24,24,5670,,0.012,0.001,2303.8,0.059,0.085,0.0044,38915.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-23",24,24,6771,,0.014,0.001,2701.6,0.059,0.107,0.0047,45635.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-24",24,24,5894,,0.012,0.001,2395.3,0.059,0.094,0.0046,40458.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-25",24,24,5779,,0.012,0.001,2350.3,0.059,0.087,0.0043,39700.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-26",24,24,6401,,0.013,0.001,2569,0.059,0.096,0.0044,43394.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-27",24,24,5849,,0.012,0.001,2366.8,0.059,0.082,0.0041,39981.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-28",24,24,5380,,0.011,0.001,2195.5,0.059,0.076,0.004,37087.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-29",24,24,5180,,0.011,0.001,2125.6,0.059,0.078,0.0044,35907.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-06-30",24,24,5119,,0.011,0.001,2107.5,0.059,0.083,0.0047,35598.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-01",24,24,5672,,0.012,0.001,2298.3,0.059,0.09,0.0047,38785.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-02",24,24,5055,,0.011,0.001,2087.2,0.059,0.073,0.0042,35224.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-03",24,24,5667,,0.012,0.001,2304.8,0.059,0.088,0.0045,38895.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-04",24,24,6038,,0.012,0.001,2430.8,0.059,0.094,0.0046,41019.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-05",24,24,5818,,0.012,0.001,2357.6,0.059,0.1,0.005,39785.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-06",24,24,5051,,0.01,0.001,2070.5,0.059,0.08,0.0046,34941.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-07",24,24,5276,,0.011,0.001,2156.6,0.059,0.079,0.0044,36393.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-08",24,24,5456,,0.011,0.001,2189,0.059,0.087,0.0047,36941.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-09",24,24,5371,,0.011,0.001,2163.4,0.059,0.083,0.0045,36507.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-10",24,24,5657,,0.012,0.001,2294.4,0.059,0.088,0.0045,38716.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-11",24,24,6328,,0.013,0.001,2528.8,0.059,0.103,0.0048,42674,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-12",24,24,5591,,0.011,0.001,2267.7,0.059,0.086,0.0045,38268.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-13",24,24,5133,,0.011,0.001,2100.3,0.059,0.067,0.0038,35445.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-14",24,24,4978,,0.01,0.001,2051.7,0.059,0.063,0.0036,34624.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-15",24,24,4828,,0.01,0.001,1991.6,0.059,0.066,0.0039,33608.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-16",24,24,4490,,0.009,0.001,1870.6,0.059,0.06,0.0038,31564.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-17",24,24,5343,,0.011,0.001,2184.3,0.059,0.073,0.004,36855.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-18",24,24,5692,,0.012,0.001,2306.8,0.059,0.072,0.0037,38932.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-19",24,24,4919,,0.01,0.001,2027.8,0.059,0.059,0.0034,34220.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-20",24,24,4996,,0.01,0.001,2060.3,0.059,0.067,0.0038,34772.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-21",24,24,5528,,0.011,0.001,2243.4,0.059,0.077,0.0041,37857,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-22",24,24,5431,,0.011,0.001,2208.9,0.059,0.072,0.0039,37274.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-23",24,24,5224,,0.011,0.001,2125.6,0.059,0.067,0.0037,35872.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-24",24,24,5529,,0.011,0.001,2236.7,0.059,0.073,0.0039,37749.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-25",24,24,6082,,0.012,0.001,2434.4,0.059,0.082,0.004,41082.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-26",24,24,6138,,0.012,0.001,2457.4,0.059,0.085,0.0041,41469.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-27",24,24,5769,,0.012,0.001,2323.2,0.059,0.077,0.004,39205.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-28",24,24,5710,,0.012,0.001,2314.3,0.059,0.084,0.0043,39056.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-29",24,24,5979,,0.012,0.001,2399.8,0.059,0.083,0.0041,40502,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-30",24,24,5956,,0.012,0.001,2393.8,0.059,0.08,0.004,40395.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-07-31",24,24,5785,,0.012,0.001,2323,0.059,0.084,0.0043,39197.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-01",24,24,5083,,0.011,0.001,2086.7,0.059,0.078,0.0044,35217.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-02",24,24,5317,,0.011,0.001,2179.2,0.059,0.076,0.004,36780.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-03",24,24,5163,,0.011,0.001,2125.1,0.059,0.067,0.0038,35862,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-04",24,24,5296,,0.011,0.001,2172.5,0.059,0.072,0.0039,36665.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-05",24,24,5006,,0.011,0.001,2074.3,0.059,0.065,0.0037,35009.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-06",24,24,4689,,0.01,0.001,1950.9,0.059,0.059,0.0036,32922.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-07",24,24,5271,,0.011,0.001,2166.8,0.059,0.074,0.004,36566.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-08",24,24,5438,,0.011,0.001,2224.6,0.059,0.076,0.004,37542.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-09",24,24,5620,,0.012,0.001,2296.3,0.059,0.087,0.0044,38752.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-10",24,24,5760,,0.012,0.001,2338.6,0.059,0.082,0.0041,39465.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-11",24,24,4999,,0.01,0.001,2070.2,0.059,0.07,0.004,34937.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-12",24,24,5908,,0.012,0.001,2391.5,0.059,0.087,0.0043,40360.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-13",24,24,6658,,0.013,0.001,2660.1,0.059,0.096,0.0043,44892,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-14",24,24,6492,,0.013,0.001,2608.5,0.059,0.102,0.0046,44024.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-15",24,24,6547,,0.013,0.001,2616.3,0.059,0.102,0.0046,44155.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-16",24,24,6321,,0.013,0.001,2537.8,0.059,0.087,0.004,42826.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-17",24,24,6545,,0.013,0.001,2633.7,0.059,0.095,0.0043,44447.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-18",24,24,6617,,0.013,0.001,2636.9,0.059,0.106,0.0048,44500.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-19",24,24,5964,,0.012,0.001,2401.8,0.059,0.091,0.0045,40528.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-20",24,24,4659,,0.01,0.001,1942.5,0.059,0.072,0.0044,32780.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-21",24,24,6170,,0.013,0.001,2484.4,0.059,0.082,0.0039,41932.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-22",24,24,6264,,0.013,0.001,2520.8,0.059,0.088,0.0041,42539.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-23",24,24,6081,,0.012,0.001,2452.8,0.059,0.091,0.0044,41396.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-24",24,24,6680,,0.014,0.001,2667.3,0.059,0.109,0.0048,45008.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-25",24,24,5822,,0.012,0.001,2357.5,0.059,0.083,0.0042,39782.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-26",24,24,5307,,0.011,0.001,2160.6,0.059,0.069,0.0038,36461.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-27",24,24,4876,,0.01,0.001,2018.9,0.059,0.058,0.0035,34070.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-28",24,24,5433,,0.011,0.001,2218.1,0.059,0.078,0.0041,37435.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-29",24,24,4961,,0.01,0.001,2054.4,0.059,0.075,0.0043,34668.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-30",24,24,4653,,0.01,0.001,1945.8,0.059,0.068,0.0041,32836.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-08-31",24,24,4942,,0.01,0.001,2053.9,0.059,0.074,0.0043,34660.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-01",24,24,5091,,0.011,0.001,2096.5,0.059,0.073,0.0041,35379.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-02",24,24,4881,,0.01,0.001,2023.2,0.059,0.068,0.004,34142.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-03",24,24,5787,,0.012,0.001,2357.9,0.059,0.079,0.0039,39793.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-04",24,24,6266,,0.013,0.001,2517.8,0.059,0.092,0.0043,42488.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-05",24,24,5534,,0.011,0.001,2213.9,0.059,0.084,0.0044,37364.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-06",24,24,5789,,0.012,0.001,2334.7,0.059,0.084,0.0042,39401,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-07",24,24,6403,,0.013,0.001,2560.8,0.059,0.098,0.0045,43216.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-08",24,24,5487,,0.011,0.001,2211.9,0.059,0.077,0.004,37327.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-09",24,24,4974,,0.01,0.001,1993.7,0.059,0.071,0.0043,33643.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-10",24,24,5404,,0.011,0.001,2162.1,0.059,0.081,0.0044,36487.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-11",24,24,5700,,0.011,0.001,2268.1,0.059,0.078,0.004,38276.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-12",24,24,5720,,0.012,0.001,2286.5,0.059,0.078,0.004,38585.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-13",24,24,5701,,0.012,0.001,2280.3,0.059,0.078,0.004,38480,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-14",24,24,5687,,0.012,0.001,2280.9,0.059,0.089,0.0046,38489.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-15",24,24,6240,,0.013,0.001,2479.8,0.059,0.091,0.0043,41848.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-16",24,24,6089,,0.012,0.001,2430,0.059,0.094,0.0046,41010.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-17",24,24,6424,,0.013,0.001,2525.5,0.059,0.087,0.0041,42620.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-18",24,24,6119,,0.012,0.001,2416.6,0.059,0.085,0.0042,40782.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-19",24,24,5514,,0.011,0.001,2220,0.059,0.076,0.004,37465.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-20",24,24,5571,,0.011,0.001,2219.6,0.059,0.078,0.0041,37459.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-21",24,24,5775,,0.012,0.001,2295.2,0.059,0.077,0.004,38730.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-22",24,24,5830,,0.012,0.001,2316.1,0.059,0.075,0.0038,39086.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-23",24,24,5241,,0.011,0.001,2094.3,0.059,0.067,0.0038,35336.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-24",24,24,5405,,0.011,0.001,2171,0.059,0.076,0.0042,36635.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-25",24,24,4865,,0.01,0.001,1970.3,0.059,0.074,0.0045,33245.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-26",24,24,4695,,0.01,0.001,1919.1,0.059,0.069,0.0043,32382.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-27",24,24,4940,,0.01,0.001,2002.5,0.059,0.067,0.004,33791.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-28",24,24,5098,,0.011,0.001,2074.8,0.059,0.073,0.0041,35015.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-29",24,24,5361,,0.011,0.001,2145.3,0.059,0.073,0.004,36202.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-09-30",24,24,6125,,0.012,0.001,2425.4,0.059,0.086,0.0042,40933.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-01",24,24,5897,,0.012,0.001,2346,0.059,0.079,0.004,39629.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-02",24,23.05,5390.05,,0.011,0.001,2163.315,0.0587,0.077,0.0091,36538.89,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-03",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-04",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-05",0,0,,,,,,,,,,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-06",11,10.12,2172,,0.004,0.0009,883.436,0.0585,0.066,0.0314,14922.596,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-07",24,24,6674,,0.013,0.001,2598.2,0.059,0.103,0.0047,43889.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-08",24,24,5328,,0.011,0.001,2124,0.059,0.076,0.0043,35878.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-09",24,24,5587,,0.011,0.001,2227,0.059,0.079,0.0042,37611.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-10",24,24,5345,,0.011,0.001,2137.3,0.059,0.073,0.004,36103.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-11",24,24,4615,,0.01,0.001,1883,0.059,0.063,0.004,31805.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-12",24,24,5195,,0.011,0.001,2089.7,0.059,0.071,0.004,35297.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-13",24,24,5801,,0.012,0.001,2293.2,0.059,0.079,0.0041,38739.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-14",24,24,6078,,0.012,0.001,2374.8,0.059,0.08,0.004,40113.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-15",24,24,6679,,0.013,0.001,2594.7,0.059,0.087,0.004,43825.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-16",24,24,5786,,0.012,0.001,2309.5,0.059,0.079,0.0041,39012,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-17",24,24,5457,,0.011,0.001,2192.3,0.059,0.078,0.0042,37032.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-18",24,24,6392,,0.013,0.001,2527.8,0.059,0.091,0.0043,42694.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-19",24,24,6494,,0.013,0.001,2563.4,0.059,0.092,0.0043,43305.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-20",24,24,6259,,0.013,0.001,2484.8,0.059,0.089,0.0043,41977,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-21",24,24,6476,,0.013,0.001,2559.8,0.059,0.084,0.0039,43238.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-22",24,24,6367,,0.013,0.001,2515.1,0.059,0.088,0.0042,42487.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-23",24,24,6347,,0.013,0.001,2513.5,0.059,0.093,0.0044,42455,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-24",24,24,6620,,0.014,0.001,2695.9,0.059,0.116,0.0051,45534.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-25",24,24,6725,,0.014,0.001,2757.4,0.059,0.117,0.005,46574.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-26",24,24,6550,,0.014,0.001,2691.8,0.059,0.112,0.0049,45472.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-27",24,24,6595,,0.014,0.001,2716.6,0.059,0.115,0.005,45885.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-28",24,24,6382,,0.013,0.001,2533.8,0.059,0.089,0.0042,42799.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-29",24,24,6150,,0.012,0.001,2456.3,0.059,0.09,0.0043,41495.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-30",24,24,6273,,0.013,0.001,2498.9,0.059,0.095,0.0045,42208,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-10-31",24,24,5867,,0.012,0.001,2359.5,0.059,0.094,0.0047,39855.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-01",24,24,6124,,0.013,0.001,2483.2,0.059,0.107,0.0051,41946.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-02",24,24,6830,,0.014,0.001,2710.7,0.059,0.108,0.0047,45786.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-03",24,24,6869,,0.014,0.001,2720.5,0.059,0.107,0.0047,45950.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-04",24,24,6684,,0.014,0.001,2677.6,0.059,0.108,0.0047,45231.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-05",24,24,6953,,0.014,0.001,2770.6,0.059,0.115,0.0049,46797.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-06",24,24,5402,,0.011,0.001,2212.6,0.059,0.087,0.0047,37372.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-07",24,24,5000,,0.011,0.001,2077.3,0.059,0.077,0.0044,35091.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-08",24,24,4963,,0.011,0.001,2073.6,0.059,0.085,0.0048,35026.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-09",24,24,5956,,0.012,0.001,2428.5,0.059,0.098,0.0048,41021.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-10",24,24,6117,,0.013,0.001,2487.1,0.059,0.092,0.0045,42016,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-11",24,24,6021,,0.012,0.001,2444.6,0.059,0.086,0.0042,41292.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-12",24,24,5662,,0.012,0.001,2321.9,0.059,0.082,0.0042,39218.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-13",24,24,6107,,0.013,0.001,2471.3,0.059,0.086,0.0042,41742.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-14",24,24,5095,,0.011,0.001,2114.9,0.059,0.069,0.0038,35727.7,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-15",24,24,5201,,0.011,0.001,2157,0.059,0.074,0.0041,36435.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-16",24,24,5606,,0.012,0.001,2291.9,0.059,0.073,0.0038,38713.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-17",24,24,6052,,0.012,0.001,2411.9,0.059,0.088,0.0044,40739.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-18",24,24,5695,,0.012,0.001,2295.9,0.059,0.083,0.0043,38782.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-19",24,24,5638,,0.012,0.001,2280.2,0.059,0.082,0.0043,38520,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-20",11,9.97,2020.27,,0.004,0.0009,859.001,0.0584,0.091,0.0395,14508.986,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-21",24,24,3151,,0.01,0.001,1901.5,0.059,0.067,0.0042,32121.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-22",24,24,2171,,0.009,0.001,1742.7,0.059,0.063,0.0043,29438.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-23",24,24,2408,,0.009,0.001,1776.4,0.059,0.062,0.0041,30006.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-24",24,24,6273,,0.013,0.001,2639.1,0.059,0.088,0.004,44582.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-25",24,24,6254,,0.013,0.001,2548.4,0.059,0.088,0.0041,43047.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-26",24,24,5724,,0.012,0.001,2359.7,0.059,0.083,0.0042,39860.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-27",24,24,5836,,0.012,0.001,2406,0.059,0.085,0.0042,40641,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-28",24,24,6304,,0.013,0.001,2574.3,0.059,0.1,0.0046,43484.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-29",24,24,6956,,0.014,0.001,2808.2,0.059,0.13,0.0055,47436.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-11-30",24,24,6414,,0.013,0.001,2612.7,0.059,0.129,0.0058,44135.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-01",24,24,6976,,0.014,0.001,2794.3,0.059,0.14,0.0059,47205.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-02",24,24,6656,,0.014,0.001,2669.3,0.059,0.133,0.0059,45088.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-03",24,24,6940,,0.014,0.001,2781.8,0.059,0.141,0.006,46987.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-04",24,24,6638,,0.014,0.001,2678.7,0.059,0.131,0.0058,45253,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-05",24,24,6544,,0.013,0.001,2651.8,0.059,0.124,0.0055,44794,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-06",24,24,6563,,0.014,0.001,2667.7,0.059,0.13,0.0058,45060.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-07",24,24,6708,,0.014,0.001,2719.5,0.059,0.135,0.0058,45932.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-08",24,24,6714,,0.014,0.001,2717.7,0.059,0.134,0.0058,45907.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-09",24,24,6333,,0.013,0.001,2580.3,0.059,0.125,0.0057,43586,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-10",24,24,6679,,0.014,0.001,2706.2,0.059,0.135,0.0059,45716.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-11",24,24,6668,,0.014,0.001,2701.6,0.059,0.133,0.0058,45632.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-12",24,24,6882,,0.014,0.001,2775.3,0.059,0.14,0.006,46880.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-13",24,24,6952,,0.014,0.001,2800.8,0.059,0.139,0.0059,47317.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-14",24,24,7059,,0.014,0.001,2843.1,0.059,0.141,0.0059,48029.8,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-15",24,24,6917,,0.014,0.001,2796.2,0.059,0.136,0.0058,47237.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-16",24,24,6979,,0.014,0.001,2813.9,0.059,0.142,0.006,47530.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-17",24,24,6264,,0.013,0.001,2548.6,0.059,0.125,0.0058,43052.4,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-18",24,24,5869,,0.012,0.001,2429.5,0.059,0.117,0.0056,41040,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-19",24,24,6144,,0.013,0.001,2521.1,0.059,0.126,0.0059,42584.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-20",24,24,5876,,0.012,0.001,2429.1,0.059,0.114,0.0055,41031.1,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-21",24,24,6758,,0.014,0.001,2741.4,0.059,0.135,0.0058,46303.6,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-22",24,24,6387,,0.013,0.001,2602.2,0.059,0.111,0.005,43956.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-23",24,24,6552,,0.014,0.001,2672.2,0.059,0.127,0.0055,45138.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-24",24,24,7138,,0.015,0.001,2879.8,0.059,0.141,0.0058,48650.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-25",24,24,6279,,0.013,0.001,2555,0.059,0.126,0.0058,43163.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-26",24,24,5851,,0.012,0.001,2409.1,0.059,0.117,0.0057,40690.9,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-27",24,24,6776,,0.014,0.001,2743.6,0.059,0.138,0.006,46346.5,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-28",24,24,7057,,0.014,0.001,2843.4,0.059,0.137,0.0057,48035.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-29",24,24,6712,,0.014,0.001,2723.3,0.059,0.127,0.0055,46001.3,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-30",24,24,6274,,0.013,0.001,2563.4,0.059,0.126,0.0058,43305,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Cosumnes Power Plant",55970,"3",,"2020-12-31",24,24,6166,,0.013,0.001,2506.7,0.059,0.122,0.0058,42344.2,"Other Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-13",18,17.77,2375.55,,0.006,0.001,1155.348,0.0591,0.189,0.0351,19437.689,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-14",1,0.57,71.82,,0,0.001,32.091,0.059,0.004,0.014,539.562,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-15",19,17.95,3841.4,,0.008,0.001,1645.315,0.059,0.111,0.0174,27687.465,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-22",1,0.1,0,,0,0.001,2.65,0.06,0.002,0.106,44.53,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-23",22,21.18,3179.94,,0.007,0.001,1473.178,0.059,0.154,0.02,24787.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-24",19,18,3356.34,,0.007,0.001,1452.478,0.059,0.071,0.0072,24441.776,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-30",16,15.62,2674.44,,0.006,0.001,1204.572,0.0591,0.251,0.0546,20269.138,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-01-31",1,0.65,81.9,,0,0.001,42.9,0.059,0.003,0.007,721.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-03",14,12.42,2351.6,,0.005,0.001,1021.398,0.059,0.092,0.0181,17186.31,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-04",20,19.6,4106.8,,0.009,0.001,1721.3,0.059,0.083,0.0071,28960.62,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-05",24,24,5132,,0.011,0.001,2143,0.059,0.09,0.005,36059.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-06",24,24,4830,,0.01,0.001,2036.4,0.059,0.087,0.0051,34266.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-07",2,1.18,166.08,,0,0.001,77.228,0.059,0.004,0.01,1299.538,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-10",20,19.88,4007.08,,0.008,0.001,1680.288,0.059,0.119,0.0134,28277.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-11",24,24,4417,,0.01,0.001,1885,0.059,0.079,0.005,31719,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-12",24,24,5672,,0.012,0.001,2343.5,0.059,0.099,0.005,39435.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-13",24,24,5671,,0.012,0.001,2353.2,0.059,0.099,0.005,39595.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-14",24,24,5726,,0.012,0.001,2378.6,0.059,0.1,0.005,40023.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-15",24,24,5705,,0.012,0.001,2366.4,0.059,0.1,0.005,39820.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-16",1,0.28,43.4,,0,0.001,18.648,0.059,0.002,0.011,313.824,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-24",22,21.35,4691.5,,0.01,0.001,1999.41,0.059,0.139,0.0172,33648.025,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-25",24,24,5711,,0.012,0.001,2352.1,0.059,0.098,0.005,39580.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-26",24,24,5265,,0.011,0.001,2166.3,0.059,0.091,0.005,36449.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-27",24,24,5661,,0.012,0.001,2326.8,0.059,0.097,0.005,39152.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-28",24,24,4700,,0.01,0.001,1985.2,0.059,0.084,0.005,33407.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-02-29",2,1.13,169.62,,0,0.001,75.905,0.059,0.004,0.0095,1276.793,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-02",23,22.62,4538.54,,0.01,0.001,1946.446,0.059,0.213,0.0286,32748.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-03",24,24,5556,,0.011,0.001,2271.8,0.059,0.096,0.005,38225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-04",24,24,5151,,0.011,0.001,2134.3,0.059,0.089,0.005,35916.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-05",24,24,5270,,0.011,0.001,2183.1,0.059,0.092,0.005,36734.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-06",24,24,5291,,0.011,0.001,2197,0.059,0.092,0.005,36971.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-07",24,24,5714,,0.012,0.001,2367.8,0.059,0.1,0.005,39840.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-08",14,12.43,2334.77,,0.005,0.001,1052.38,0.059,0.078,0.0164,17708.129,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-09",24,24,5689,,0.012,0.001,2332.5,0.059,0.098,0.005,39250.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-10",24,24,6068,,0.013,0.001,2500.4,0.059,0.105,0.005,42077.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-11",24,24,5401,,0.011,0.001,2242.3,0.059,0.094,0.005,37730.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-12",24,24,6075,,0.013,0.001,2533.7,0.059,0.105,0.0049,42634.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-13",24,24,5936,,0.012,0.001,2472.3,0.059,0.104,0.005,41596.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-14",1,0.47,44.65,,0,0.001,27.965,0.059,0.002,0.008,470.235,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-15",8,7.88,1920.56,,0.004,0.001,830.964,0.059,0.066,0.0166,13980.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-16",24,24,6174,,0.013,0.001,2556.1,0.059,0.108,0.005,43012.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-17",24,24,6361,,0.013,0.001,2563.3,0.059,0.108,0.005,43127,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-18",24,24,5953,,0.012,0.001,2431.2,0.059,0.102,0.005,40910.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-19",24,24,5351,,0.011,0.001,2239.1,0.059,0.094,0.005,37670.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-20",24,24,5310,,0.011,0.001,2205.7,0.059,0.093,0.005,37117.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-21",24,24,5755,,0.012,0.001,2374.3,0.059,0.1,0.005,39954.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-22",9,8.3,1937.3,,0.004,0.001,800.36,0.059,0.035,0.0059,13468.89,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-28",7,6.12,1057.6,,0.002,0.001,481.308,0.059,0.096,0.054,8098.332,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-29",9,8.43,1965.93,,0.004,0.001,814.953,0.059,0.036,0.0059,13712.713,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-30",5,4.8,831.4,,0.002,0.001,378.7,0.0592,0.063,0.0454,6371.86,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-03-31",17,15.47,3461.06,,0.007,0.001,1443.241,0.059,0.077,0.012,24283.402,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-01",10,9.27,2166.5,,0.005,0.001,897.704,0.059,0.038,0.005,15108.209,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-06",23,22.02,5021,,0.011,0.001,2092.28,0.059,0.13,0.0121,35203.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-07",24,24,4779,,0.01,0.001,1997.9,0.059,0.084,0.005,33617.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-08",1,0.43,39.56,,0,0.001,25.37,0.059,0.002,0.008,427.033,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-19",5,3.66,340.89,,0.001,0.001,209.078,0.059,0.083,0.0906,3519.959,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-20",24,24,5389,,0.012,0.001,2294.5,0.059,0.097,0.005,38609.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-21",1,0.47,42.77,,0,0.001,27.448,0.059,0.002,0.009,462.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-24",10,9.33,2010.62,,0.004,0.001,860.069,0.059,0.088,0.0328,14472.954,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-25",17,15.61,3652.82,,0.008,0.001,1537.153,0.059,0.072,0.0076,25863.727,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-28",15,13.32,2657.04,,0.006,0.001,1144.352,0.059,0.092,0.0209,19257.548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-29",14,13.68,2640.32,,0.006,0.001,1146.56,0.059,0.067,0.0096,19293.556,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-04-30",16,14.65,3263.45,,0.007,0.001,1380.995,0.059,0.07,0.0124,23237.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-01",10,9.03,2001.77,,0.004,0.001,874.261,0.059,0.048,0.0089,14710.794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-02",6,5.38,921.64,,0.002,0.001,396.654,0.059,0.018,0.0065,6675.414,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-04",16,15.8,3253.8,,0.007,0.001,1411.1,0.059,0.14,0.0243,23744.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-05",24,23.48,5254.48,,0.011,0.001,2215.572,0.059,0.093,0.005,37277.944,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-06",13,11.92,2613.78,,0.006,0.001,1097.35,0.059,0.059,0.0085,18465.279,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-07",15,14.08,3055.68,,0.007,0.001,1295.746,0.059,0.065,0.0078,21798.954,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-08",14,13.28,2628.92,,0.006,0.001,1123.62,0.059,0.057,0.0079,18909.064,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-09",7,6.01,1340.01,,0.003,0.001,567.014,0.059,0.039,0.0111,9540.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-10",2,1.42,199.82,,0,0.001,91.026,0.059,0.004,0.006,1532.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-22",6,5.17,680.68,,0.002,0.001,322.39,0.059,0.069,0.0488,5426.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-23",14,12.85,2457.83,,0.005,0.001,1059.897,0.059,0.055,0.0081,17832.692,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-24",7,6.2,930.8,,0.002,0.001,414.98,0.059,0.018,0.0057,6985.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-25",9,7.99,1890.88,,0.004,0.001,804.247,0.059,0.057,0.0157,13531.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-26",14,13.38,2935.82,,0.006,0.001,1256.912,0.059,0.072,0.0105,21149.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-27",14,13.19,3009.46,,0.006,0.001,1273.178,0.059,0.07,0.0091,21424.138,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-28",14,13.6,2984,,0.006,0.001,1261.16,0.059,0.068,0.0089,21221.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-29",15,13.08,2868.78,,0.006,0.001,1209.272,0.059,0.074,0.0121,20351.806,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-01",14,12.97,2785.86,,0.006,0.001,1165.548,0.0591,0.09,0.0191,19613.539,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-02",14,12.8,2851.78,,0.006,0.001,1194.616,0.059,0.068,0.0101,20102.644,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-03",15,14.45,3353.64,,0.007,0.001,1397.732,0.059,0.066,0.0077,23521.808,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-04",11,10.03,1879.5,,0.004,0.001,811.115,0.059,0.046,0.0096,13648.306,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-09",19,17.78,4285.3,,0.009,0.001,1828.498,0.059,0.162,0.0235,30769.154,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-10",20,19.12,4623.32,,0.01,0.001,1974.36,0.059,0.107,0.0072,33220.678,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-11",19,18.6,4528.4,,0.01,0.001,1881.98,0.059,0.101,0.0075,31670.54,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-12",24,23.18,5263.02,,0.011,0.001,2161.414,0.059,0.11,0.0063,36370.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-18",9,8.58,1704.4,,0.004,0.001,734.388,0.059,0.089,0.0328,12359.096,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-19",1,0.23,27.83,,0,0.001,14.421,0.059,0.001,0.009,242.627,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-22",15,14.55,3382.35,,0.007,0.001,1407.78,0.059,0.13,0.0206,23684.61,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-23",15,13.95,3348.85,,0.007,0.001,1393.635,0.059,0.078,0.0085,23450.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-24",16,15.2,3574.31,,0.008,0.001,1489.999,0.059,0.086,0.0079,25071.078,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-25",15,13.8,3135.22,,0.007,0.001,1306.544,0.059,0.084,0.0113,21982.79,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-26",15,13.88,3316.22,,0.007,0.001,1373.152,0.059,0.089,0.0119,23106.598,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-27",15,13.75,3452.38,,0.007,0.001,1418.569,0.059,0.088,0.0108,23871.563,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-28",1,0.42,36.96,,0,0.001,23.982,0.059,0.002,0.009,403.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-29",7,6.52,1195.72,,0.003,0.001,537.216,0.059,0.075,0.0437,9040.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-06-30",24,24,5312,,0.011,0.001,2218.3,0.059,0.112,0.006,37323.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-01",2,1.45,335.2,,0.001,0.001,136.66,0.059,0.007,0.007,2299.945,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-03",15,14.25,3315.25,,0.007,0.001,1383.725,0.0591,0.111,0.0229,23281.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-04",16,14.05,3295.94,,0.007,0.001,1361.831,0.059,0.086,0.0108,22917.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-05",14,12.8,2994.88,,0.006,0.001,1236.862,0.059,0.084,0.0118,20814.367,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-06",17,16.54,3401.41,,0.007,0.001,1424.287,0.059,0.081,0.0081,23965.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-07",14,12.83,2777.88,,0.006,0.001,1154.037,0.059,0.075,0.0109,19419.355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-08",14,12.77,2765.02,,0.006,0.001,1157.435,0.059,0.078,0.012,19479.898,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-09",11,9.82,2315.7,,0.005,0.001,964.8,0.059,0.064,0.0123,16234.911,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-10",14,13.09,3140.76,,0.007,0.001,1301.884,0.059,0.084,0.012,21908.686,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-11",14,12.82,3127.4,,0.007,0.001,1306.3,0.059,0.082,0.0101,21981.548,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-12",14,12.87,3081.39,,0.006,0.001,1282.825,0.059,0.083,0.0114,21585.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-13",14,12.98,3070.45,,0.006,0.001,1282.198,0.059,0.083,0.0119,21575.518,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-14",14,12.77,2648.7,,0.006,0.001,1107.987,0.059,0.073,0.0111,18644.097,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-15",14,12.8,2332.4,,0.005,0.001,1002.04,0.059,0.069,0.0114,16862.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-16",14,12.77,2431.29,,0.005,0.001,1035.303,0.059,0.076,0.0135,17422.221,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-17",14,12.94,2607.39,,0.006,0.001,1092.788,0.059,0.074,0.0115,18391.947,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-18",19,17.49,4062.64,,0.009,0.001,1696.06,0.059,0.096,0.0089,28539.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-19",19,17.5,3519.1,,0.007,0.001,1481.69,0.059,0.088,0.0102,24930,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-20",19,17.47,3621.82,,0.008,0.001,1530.25,0.0591,0.085,0.0074,25750.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-21",19,17.77,4074.7,,0.009,0.001,1704.093,0.059,0.093,0.0085,28678.776,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-23",15,14.23,3003.61,,0.006,0.001,1283.201,0.059,0.107,0.0219,21595.528,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-24",17,15.35,3371.51,,0.007,0.001,1404.881,0.059,0.081,0.0114,23640.934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-26",15,14.3,3071.9,,0.007,0.001,1307.02,0.059,0.099,0.0172,21994.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-27",24,23.53,4826.79,,0.01,0.001,2005.212,0.059,0.102,0.0061,33741.345,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-28",14,12.75,2846.97,,0.006,0.001,1184.143,0.059,0.079,0.0124,19926.794,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-29",16,14.8,3330.98,,0.007,0.001,1391.242,0.059,0.08,0.009,23410.851,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-30",14,13.57,3222.34,,0.007,0.001,1354.088,0.059,0.086,0.0119,22784.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-07-31",24,23.22,4947.64,,0.01,0.001,2072.338,0.059,0.104,0.006,34874.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-01",17,15.79,3090.05,,0.007,0.001,1302.445,0.059,0.072,0.008,21916.093,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-02",14,12.86,2722,,0.006,0.001,1137.514,0.059,0.071,0.0094,19140.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-03",14,12.84,2738.18,,0.006,0.001,1143.36,0.059,0.072,0.0101,19240.372,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-04",14,12.88,2550.7,,0.005,0.001,1070.832,0.059,0.068,0.0101,18015.382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-07",14,13.07,2835.97,,0.006,0.001,1188.147,0.059,0.105,0.0178,19994.727,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-08",14,13.57,3114.74,,0.006,0.001,1287.121,0.059,0.079,0.0098,21659.071,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-09",15,13.81,3215.15,,0.007,0.001,1323.886,0.059,0.083,0.0099,22277.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-10",14,12.82,3075.6,,0.006,0.001,1264.179,0.059,0.079,0.0101,21270.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-11",14,13.54,2839.9,,0.006,0.001,1178.209,0.059,0.075,0.0106,19824.825,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-12",11,10.58,2478.66,,0.005,0.001,1020.898,0.059,0.061,0.0093,17179.656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-13",15,13.41,3004.94,,0.006,0.001,1262.399,0.059,0.075,0.0085,21241.183,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-14",18,17.57,4095.88,,0.009,0.001,1723.864,0.059,0.093,0.0072,29007.174,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-15",18,17.06,3844.36,,0.008,0.001,1620.9,0.059,0.097,0.0103,27276.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-16",18,16.62,3176.27,,0.007,0.001,1343.712,0.0591,0.077,0.0098,22610.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-17",18,16.8,3666.5,,0.008,0.001,1575.645,0.059,0.087,0.008,26514.585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-18",24,24,4922,,0.011,0.001,2094.5,0.059,0.106,0.006,35248.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-19",24,24,4828,,0.01,0.001,2036.3,0.059,0.103,0.006,34263.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-20",24,23.47,4649.51,,0.01,0.001,1963.09,0.059,0.1,0.0061,33035.406,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-21",15,14.24,3301.29,,0.007,0.001,1362.857,0.059,0.075,0.0077,22932.138,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-22",15,14.53,3458.75,,0.007,0.001,1425.572,0.059,0.079,0.008,23983.648,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-23",15,14.18,3381.23,,0.007,0.001,1401.011,0.059,0.082,0.0083,23576.798,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-24",16,14.42,3333.65,,0.007,0.001,1380.81,0.059,0.076,0.0102,23233.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-25",15,14.3,3280.9,,0.007,0.001,1371.21,0.059,0.076,0.0095,23071.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-26",24,24,4942,,0.01,0.001,2056.1,0.059,0.102,0.0059,34595.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-27",24,24,4811,,0.01,0.001,2039.8,0.059,0.102,0.0059,34327.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-28",24,24,4556,,0.01,0.001,1926.7,0.059,0.097,0.006,32420.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-29",24,23.27,4108.07,,0.009,0.001,1735.455,0.059,0.088,0.0061,29200.414,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-30",19,17.3,3342.3,,0.007,0.001,1408.58,0.059,0.078,0.0078,23702.215,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-08-31",17,15.3,2691.25,,0.006,0.001,1157.256,0.059,0.065,0.0083,19471.697,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-01",16,15.32,2952.6,,0.006,0.001,1243.348,0.059,0.077,0.0144,20920.424,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-02",15,13.95,2863.72,,0.006,0.001,1204.562,0.059,0.072,0.0083,20268.403,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-03",24,24,4402,,0.009,0.001,1873.1,0.059,0.095,0.006,31521.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-04",24,23.25,4695,,0.01,0.001,1984.7,0.059,0.1,0.0061,33399.025,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-05",16,15.32,3708.08,,0.008,0.001,1581.728,0.059,0.087,0.0104,26613.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-06",24,24,5727,,0.012,0.001,2397.5,0.059,0.121,0.006,40340.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-07",16,14.5,2729.35,,0.006,0.001,1151.014,0.059,0.064,0.0078,19369.829,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-08",14,13.57,2533.75,,0.005,0.001,1061.267,0.059,0.069,0.0103,17859.724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-09",24,23.25,5166.25,,0.011,0.001,2162.8,0.059,0.11,0.0061,36393.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-10",14,13.55,2627.95,,0.005,0.001,1087.76,0.059,0.074,0.0119,18303.615,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-11",24,24,5913,,0.012,0.001,2423.3,0.059,0.122,0.006,40774.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-12",24,24,5627,,0.012,0.001,2306.6,0.059,0.115,0.0059,38814,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-13",24,24,5588,,0.012,0.001,2296.7,0.059,0.116,0.006,38645.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-14",24,24,5782,,0.012,0.001,2390.8,0.059,0.121,0.006,40233,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-15",24,24,5484,,0.011,0.001,2259.9,0.059,0.114,0.006,38031.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-16",24,24,5576,,0.012,0.001,2301.9,0.059,0.115,0.0059,38733.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-17",24,24,5796,,0.012,0.001,2389.7,0.059,0.121,0.006,40211.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-18",24,24,4628,,0.01,0.001,1952.9,0.059,0.099,0.006,32861.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-19",24,24,3725,,0.008,0.001,1609.4,0.059,0.081,0.006,27080.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-20",24,24,5615,,0.012,0.001,2312.2,0.059,0.117,0.006,38904.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-21",24,24,5825,,0.012,0.001,2388,0.059,0.121,0.006,40182.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-22",24,24,5837,,0.012,0.001,2400,0.059,0.121,0.006,40382.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-23",24,24,5774,,0.012,0.001,2382.3,0.059,0.12,0.006,40084.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-24",17,15.39,3113.91,,0.007,0.001,1313.168,0.059,0.077,0.0093,22094.773,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-25",24,24,5031,,0.01,0.001,2072.2,0.059,0.105,0.006,34867.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-26",17,15.73,3073.43,,0.006,0.001,1279.928,0.059,0.078,0.0099,21534.927,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-27",24,24,5114,,0.011,0.001,2107.9,0.059,0.106,0.006,35467.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-28",24,24,5289,,0.011,0.001,2192.4,0.059,0.112,0.006,36892.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-29",24,24,5613,,0.012,0.001,2316.3,0.059,0.118,0.0061,38976.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-09-30",19,17.79,4127.37,,0.009,0.001,1737.931,0.059,0.092,0.0077,29244.493,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-01",24,24,5308,,0.011,0.001,2206.3,0.059,0.111,0.006,37124.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-02",24,24,5270,,0.011,0.001,2165.3,0.059,0.109,0.006,36435.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-03",24,24,4832,,0.01,0.001,1987.7,0.059,0.1,0.006,33446.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-04",24,24,5089,,0.011,0.001,2083.9,0.059,0.105,0.006,35065.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-05",11,10.25,1504,,0.003,0.001,662.425,0.059,0.034,0.0064,11146.175,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-11",15,14.2,2814,,0.006,0.001,1191.54,0.059,0.113,0.0255,20049.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-12",24,24,5349,,0.011,0.001,2204,0.059,0.111,0.006,37086.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-13",24,24,5832,,0.012,0.001,2423,0.059,0.122,0.006,40771.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-14",24,24,5238,,0.011,0.001,2187.3,0.059,0.11,0.006,36806.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-15",12,11.18,2348.32,,0.005,0.001,968.37,0.059,0.049,0.0063,16293.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-17",1,0.13,0.13,,0,0.001,3.406,0.059,0.005,0.179,57.382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-30",4,0.73,6.7,,0,0.001,21.089,0.0595,0.03,0.1323,354.759,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-10-31",11,10.27,2112.13,,0.005,0.001,893.84,0.059,0.107,0.0395,15040.887,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-01",24,24,5548,,0.012,0.001,2294.1,0.059,0.116,0.006,38601.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-02",24,24,5718,,0.012,0.001,2323.3,0.059,0.116,0.0059,39090.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-03",24,24,5440,,0.011,0.001,2241.9,0.059,0.113,0.006,37722.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-04",24,24,5464,,0.011,0.001,2226.2,0.059,0.112,0.006,37458.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-05",24,24,5583,,0.012,0.001,2298.6,0.059,0.116,0.006,38684.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-06",24,23.48,4901.52,,0.01,0.001,2037.696,0.059,0.103,0.006,34288.596,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-08",14,13.7,2962.1,,0.006,0.001,1268.46,0.059,0.11,0.0176,21348.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-09",16,14.45,2700.11,,0.006,0.001,1165.807,0.059,0.083,0.0105,19615.254,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-10",24,24,5559,,0.011,0.001,2262.2,0.059,0.114,0.006,38064,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-11",24,24,5312,,0.011,0.001,2168.8,0.059,0.109,0.006,36498.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-12",24,24,5267,,0.011,0.001,2162.9,0.059,0.109,0.006,36395,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-13",9,8.27,1781.1,,0.004,0.001,732.258,0.059,0.038,0.0064,12323.508,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-14",3,2.37,138.07,,0.001,0.001,116.859,0.059,0.057,0.1037,1965.942,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-15",24,24,4954,,0.01,0.001,2031,0.059,0.103,0.006,34170.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-16",24,24,5203,,0.011,0.001,2121.5,0.059,0.107,0.006,35698.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-17",24,24,5069,,0.01,0.001,2077.5,0.059,0.105,0.006,34959.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-18",13,11.95,2078.62,,0.005,0.001,903.504,0.059,0.06,0.0127,15204.814,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-19",14,12.77,2575.53,,0.005,0.001,1084.272,0.059,0.066,0.0098,18247.001,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-20",24,24,5416,,0.011,0.001,2211.7,0.059,0.112,0.006,37215.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-21",24,24,5580,,0.012,0.001,2283.3,0.059,0.115,0.006,38419.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-22",24,24,5239,,0.011,0.001,2137.2,0.059,0.108,0.006,35962.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-23",24,24,5249,,0.011,0.001,2176,0.059,0.111,0.006,36616.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-24",24,24,5655,,0.012,0.001,2317.9,0.059,0.117,0.006,39004.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-25",24,24,5308,,0.011,0.001,2169.1,0.059,0.11,0.006,36500.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-26",18,17.3,3952.7,,0.008,0.001,1649.212,0.059,0.096,0.0079,27750.028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-27",24,24,4876,,0.01,0.001,2007.6,0.059,0.101,0.006,33781.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-28",16,14.87,3394.91,,0.007,0.001,1391.939,0.059,0.08,0.0088,23423.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-29",16,14.8,3479.57,,0.007,0.001,1416.321,0.059,0.084,0.0096,23831.048,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-11-30",24,24,5407,,0.011,0.001,2201.3,0.059,0.111,0.006,37036.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-01",24,24,5325,,0.011,0.001,2197.1,0.059,0.111,0.006,36969.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-02",24,24,5038,,0.011,0.001,2085.7,0.059,0.105,0.006,35091.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-03",24,24,5212,,0.011,0.001,2154,0.059,0.107,0.0059,36244.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-04",19,18.31,3807.56,,0.008,0.001,1601.351,0.059,0.092,0.0077,26944.219,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-05",24,24,5397,,0.011,0.001,2210,0.059,0.112,0.006,37183.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-06",24,24,5121,,0.011,0.001,2111.4,0.059,0.107,0.006,35526.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-07",24,24,5491,,0.011,0.001,2248.6,0.059,0.112,0.0059,37838.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-08",24,24,4670,,0.01,0.001,1944.3,0.059,0.098,0.006,32712.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-09",19,18.27,3617.57,,0.008,0.001,1525.708,0.059,0.086,0.0072,25670.986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-10",23,22.25,4662.25,,0.01,0.001,1926.775,0.059,0.097,0.0061,32427.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-11",20,19.73,4157.15,,0.009,0.001,1737.809,0.059,0.098,0.0075,29240.799,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-12",24,24,5246,,0.011,0.001,2165,0.059,0.109,0.006,36430.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-13",24,24,5647,,0.012,0.001,2309.2,0.059,0.115,0.0059,38860.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-14",24,24,4979,,0.01,0.001,2070.7,0.059,0.105,0.006,34843.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-15",24,24,5258,,0.011,0.001,2167.3,0.059,0.109,0.006,36467.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-16",24,24,5392,,0.011,0.001,2219.4,0.059,0.112,0.006,37340.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-17",24,24,4681,,0.01,0.001,1954,0.059,0.099,0.006,32878.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-18",24,24,4942,,0.01,0.001,2066.5,0.059,0.103,0.0059,34771.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-19",24,24,4818,,0.01,0.001,2012,0.059,0.102,0.006,33854.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-20",1,0.32,56.32,,0,0.001,25.952,0.059,0.002,0.008,436.864,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-22",20,19.57,3823.67,,0.008,0.001,1610.993,0.059,0.138,0.0192,27107.833,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-23",24,24,4827,,0.01,0.001,2013.7,0.059,0.098,0.0058,33884.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-24",24,24,4947,,0.01,0.001,2046.7,0.059,0.103,0.006,34441,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-25",10,8.85,1423.62,,0.003,0.001,632.864,0.059,0.052,0.0145,10649.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-26",18,16.95,2712.56,,0.006,0.001,1195.654,0.059,0.076,0.0099,20122.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-27",24,24,4435,,0.009,0.001,1859.8,0.059,0.094,0.006,31295.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-28",24,24,4937,,0.01,0.001,2035.4,0.059,0.103,0.006,34252.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-29",24,24,4828,,0.01,0.001,2001.2,0.059,0.102,0.006,33673.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-30",24,24,4748,,0.01,0.001,1979.9,0.059,0.099,0.0059,33316.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG1",,"2020-12-31",24,24,4898,,0.01,0.001,2026,0.059,0.102,0.006,34090.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-13",12,11.85,1846.35,,0.004,0.001,829.11,0.059,0.105,0.0268,13951.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-14",18,16.46,3570.88,,0.008,0.001,1513.83,0.059,0.086,0.0084,25470.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-16",18,17.25,3710.84,,0.008,0.001,1583.644,0.059,0.104,0.0138,26649.819,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-23",18,16.97,2777.24,,0.006,0.001,1222.19,0.059,0.107,0.0181,20567.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-24",18,17.15,3199.8,,0.007,0.001,1360.515,0.059,0.068,0.0073,22895.525,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-30",11,10.1,2114.2,,0.004,0.001,884.09,0.059,0.096,0.0318,14876.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-01-31",4,3.37,707.8,,0.001,0.001,294.077,0.059,0.015,0.008,4948.624,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-03",21,20.75,3888.75,,0.009,0.001,1686.675,0.059,0.178,0.0245,28380.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-04",24,24,5222,,0.011,0.001,2163.1,0.059,0.092,0.005,36398.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-05",24,24,5193,,0.011,0.001,2143.6,0.059,0.09,0.005,36070.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-06",24,24,4899,,0.01,0.001,2035.3,0.059,0.085,0.005,34242.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-07",24,24,5663,,0.012,0.001,2345.9,0.059,0.106,0.0054,39474.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-08",9,8.32,1949.16,,0.004,0.001,807.136,0.059,0.037,0.006,13582.828,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-10",23,22.6,4303.4,,0.009,0.001,1838.8,0.059,0.161,0.0208,30946.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-11",17,16.15,2562.9,,0.006,0.001,1116.505,0.059,0.048,0.0054,18787.305,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-17",3,2.82,141.66,,0.001,0.001,117.16,0.059,0.075,0.091,1971.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-18",24,24,5770,,0.012,0.001,2392,0.059,0.103,0.0051,40246,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-19",24,24,5779,,0.012,0.001,2387.3,0.059,0.1,0.005,40173.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-20",24,24,5835,,0.012,0.001,2404.8,0.059,0.102,0.005,40464.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-21",24,24,5823,,0.012,0.001,2406.4,0.059,0.101,0.005,40491.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-22",10,9.3,2194.9,,0.005,0.001,911.55,0.059,0.039,0.0055,15336.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-25",21,20.63,4728.98,,0.01,0.001,1948.708,0.059,0.133,0.013,32787.011,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-26",24,24,5279,,0.011,0.001,2158.4,0.059,0.089,0.0049,36314,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-27",24,24,5673,,0.012,0.001,2315.8,0.059,0.097,0.005,38969.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-28",24,24,4729,,0.01,0.001,1977,0.059,0.083,0.005,33268.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-02-29",2,1.3,194,,0,0.001,84.32,0.059,0.005,0.011,1418.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-02",20,19.65,4279.35,,0.009,0.001,1764.43,0.059,0.115,0.0132,29689.115,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-03",24,24,5551,,0.011,0.001,2262.3,0.059,0.096,0.005,38069.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-04",24,24,5182,,0.011,0.001,2134.2,0.059,0.089,0.005,35909.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-05",24,24,5285,,0.011,0.001,2176.7,0.059,0.092,0.005,36630.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-06",24,24,5280,,0.011,0.001,2184.3,0.059,0.091,0.005,36755.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-07",10,8.5,1743.47,,0.004,0.001,749.922,0.059,0.063,0.0265,12617.607,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-08",2,1.82,271.74,,0.001,0.001,133.69,0.059,0.04,0.0605,2249.324,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-09",24,24,5622,,0.012,0.001,2295.3,0.059,0.096,0.005,38622.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-10",24,24,6000,,0.012,0.001,2459,0.059,0.103,0.005,41374.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-11",24,24,5332,,0.011,0.001,2206.6,0.059,0.093,0.005,37129.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-12",24,24,6031,,0.013,0.001,2507.3,0.059,0.106,0.005,42185.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-13",24,24,5914,,0.012,0.001,2450.2,0.059,0.104,0.005,41228.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-14",24,24,5791,,0.012,0.001,2386.5,0.059,0.11,0.0055,40155.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-15",24,24,5783,,0.012,0.001,2417.1,0.059,0.106,0.0052,40674.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-16",24,24,6110,,0.013,0.001,2522.3,0.059,0.107,0.005,42442.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-17",24,24,6305,,0.013,0.001,2524.6,0.059,0.106,0.005,42484.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-18",24,24,5893,,0.012,0.001,2387,0.059,0.102,0.0051,40167.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-19",24,24,5350,,0.011,0.001,2221.7,0.059,0.094,0.005,37383.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-20",24,24,5295,,0.011,0.001,2184.4,0.059,0.094,0.0051,36755.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-21",3,2.17,479.54,,0.001,0.001,200.023,0.059,0.009,0.007,3365.246,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-22",5,4.6,749.2,,0.002,0.001,357.74,0.059,0.073,0.057,6018.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-23",24,24,5693,,0.012,0.001,2348.5,0.059,0.103,0.0052,39521.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-24",24,24,5738,,0.012,0.001,2365.9,0.059,0.1,0.005,39811.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-25",24,24,5754,,0.012,0.001,2378.3,0.059,0.105,0.0053,40018.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-26",24,24,5827,,0.012,0.001,2401.4,0.059,0.104,0.0051,40404.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-27",9,8.33,1957.18,,0.004,0.001,810.85,0.059,0.04,0.0064,13644.386,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-29",6,5.1,885,,0.002,0.001,405.2,0.059,0.059,0.0483,6818.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-30",10,9.25,2199.5,,0.005,0.001,905.775,0.059,0.039,0.0056,15240.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-01",6,5.33,984.95,,0.002,0.001,449.086,0.0592,0.059,0.0405,7557.451,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-02",16,14.55,3307.88,,0.007,0.001,1384.003,0.059,0.073,0.0114,23288.674,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-03",8,7.47,1772.67,,0.004,0.001,734.117,0.059,0.032,0.0056,12353.261,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-04",6,5.85,1061.9,,0.002,0.001,476.85,0.059,0.065,0.0343,8024.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-05",14,12.94,2947.46,,0.006,0.001,1236.348,0.0591,0.07,0.0092,20801.378,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-06",24,24,5677,,0.012,0.001,2329.5,0.059,0.098,0.005,39197.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-07",24,24,4872,,0.01,0.001,2016.1,0.059,0.085,0.005,33923.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-08",24,24,5822,,0.012,0.001,2410.9,0.059,0.101,0.005,40568.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-09",24,24,5821,,0.012,0.001,2412.8,0.059,0.102,0.005,40602.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-10",24,24,5816,,0.012,0.001,2412.8,0.059,0.102,0.005,40601.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-11",8,7.35,1737.65,,0.004,0.001,719.075,0.059,0.032,0.0061,12099.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-16",6,5.48,410.28,,0.001,0.001,269.012,0.059,0.108,0.0748,4524.864,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-17",24,24,5695,,0.012,0.001,2392.7,0.059,0.102,0.0051,40258.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-18",7,6.58,1552.46,,0.003,0.001,646.962,0.059,0.029,0.0056,10885.666,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-20",9,8.38,1531.98,,0.003,0.001,671.074,0.059,0.077,0.0329,11291.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-21",8,7.35,1658.25,,0.004,0.001,695.825,0.059,0.03,0.0056,11709.885,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-22",7,6.72,1290.24,,0.003,0.001,572.468,0.059,0.066,0.0299,9632.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-23",8,7.17,1705.66,,0.004,0.001,711.811,0.059,0.031,0.0064,11979.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-24",15,14.17,3061.85,,0.007,0.001,1325.213,0.059,0.093,0.0173,22301.788,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-25",20,19.1,4404.9,,0.009,0.001,1843.025,0.059,0.088,0.0074,31007.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-26",2,1.63,347.29,,0.001,0.001,146.696,0.059,0.007,0.0065,2468.238,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-27",15,14.16,3020.52,,0.007,0.001,1291.144,0.059,0.091,0.016,21725.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-28",16,14.57,2938.07,,0.006,0.001,1258.129,0.0591,0.069,0.0089,21172.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-29",15,14.72,2808.44,,0.006,0.001,1223.512,0.059,0.063,0.0075,20591.392,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-04-30",1,0.17,14.28,,0,0.001,9.214,0.059,0.001,0.011,155.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-01",9,8.93,1801.18,,0.004,0.001,813.142,0.059,0.069,0.0176,13682.476,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-02",4,3.68,539.88,,0.001,0.001,243.688,0.059,0.011,0.0055,4100.296,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-05",15,14.05,2848.05,,0.006,0.001,1212.185,0.059,0.091,0.0199,20398.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-06",24,23.37,5318.25,,0.011,0.001,2202.665,0.059,0.091,0.0051,37063.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-07",16,15.47,3195.34,,0.007,0.001,1353.993,0.059,0.074,0.0089,22784.466,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-08",15,14.67,2760.48,,0.006,0.001,1197.257,0.059,0.061,0.0073,20142.817,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-09",15,14.08,3175.08,,0.007,0.001,1328.34,0.059,0.08,0.0111,22348.992,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-10",8,6.78,1286,,0.003,0.001,552.05,0.059,0.041,0.0213,9288.336,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-11",9,8.45,1917.6,,0.004,0.001,794.185,0.059,0.035,0.0058,13362.405,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-22",12,11.55,1356.15,,0.004,0.001,702.935,0.059,0.233,0.0733,11829.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-23",15,14.07,2581.12,,0.006,0.001,1126.322,0.059,0.059,0.0085,18953.577,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-24",14,12.4,2230.7,,0.005,0.001,969.105,0.059,0.055,0.009,16306.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-25",24,23.5,5517.5,,0.012,0.001,2312.55,0.059,0.099,0.0052,38912.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-26",15,14.6,3054.4,,0.007,0.001,1316.26,0.059,0.067,0.0084,22147.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-27",20,17.98,3994.26,,0.009,0.001,1684.872,0.059,0.08,0.0104,28350.022,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-28",15,14.58,3066.58,,0.007,0.001,1309.786,0.059,0.063,0.0073,22038.242,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-29",16,14.57,3052.93,,0.007,0.001,1293.173,0.059,0.066,0.0081,21759.97,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-01",17,16.38,3136.1,,0.007,0.001,1344.484,0.059,0.153,0.027,22626.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-02",15,14.26,3095.12,,0.007,0.001,1299.826,0.059,0.066,0.0071,21871.656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-03",16,15.58,3513.68,,0.007,0.001,1472.804,0.059,0.073,0.0081,24782.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-04",16,13.82,2674.87,,0.006,0.001,1139.646,0.059,0.065,0.0105,19175.338,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-05",15,14.08,3132,,0.007,0.001,1301.864,0.059,0.07,0.0099,21909.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-06",1,0.3,45.3,,0,0.001,19.86,0.059,0.002,0.01,334.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-09",23,21.97,4744.95,,0.01,0.001,2065.795,0.059,0.206,0.0258,34760.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-10",19,18,4470.74,,0.009,0.001,1874.862,0.059,0.088,0.0072,31545.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-11",20,19.83,4649.33,,0.01,0.001,1966.251,0.059,0.091,0.0063,33084.314,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-12",24,23.33,5346.6,,0.011,0.001,2203.856,0.059,0.094,0.0054,37082.516,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-14",7,5.92,820.44,,0.002,0.001,406.1,0.059,0.086,0.0529,6834.712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-15",24,23.27,5513.82,,0.011,0.001,2273.697,0.059,0.096,0.0052,38256.809,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-18",17,16.08,3070.08,,0.007,0.001,1341.94,0.059,0.155,0.0319,22580.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-19",16,14.67,3246.29,,0.007,0.001,1355.099,0.059,0.087,0.0159,22804.107,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-20",18,16.25,3682.84,,0.008,0.001,1530.902,0.059,0.08,0.0098,25758.34,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-21",16,13.86,3003.94,,0.006,0.001,1274.604,0.059,0.081,0.0112,21448.224,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-22",19,18.08,4233.4,,0.009,0.001,1751.876,0.059,0.084,0.0082,29481.172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-23",16,15.28,3477.8,,0.007,0.001,1459.014,0.059,0.075,0.0083,24552.908,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-24",20,19.15,4397.81,,0.009,0.001,1824.926,0.059,0.084,0.0062,30707.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-25",16,14.97,3273.78,,0.007,0.001,1372.438,0.059,0.071,0.0093,23092.746,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-26",16,15.19,3454.7,,0.007,0.001,1440.608,0.059,0.076,0.0094,24238.171,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-27",16,15.27,3639.77,,0.008,0.001,1512.107,0.059,0.075,0.0071,25445.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-28",14,12.71,2858.86,,0.006,0.001,1184.309,0.059,0.064,0.01,19927.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-29",7,6.6,1500.8,,0.003,0.001,617.8,0.059,0.028,0.0056,10396.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-06-30",12,11.78,2375.8,,0.005,0.001,1013.844,0.059,0.072,0.0134,17062.508,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-01",17,15.8,3555.51,,0.007,0.001,1467.811,0.059,0.091,0.0125,24704.768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-02",24,24,5679,,0.012,0.001,2335,0.059,0.098,0.005,39293.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-03",21,19.4,4476.92,,0.009,0.001,1860.564,0.059,0.087,0.0072,31309.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-04",17,15.3,3426.95,,0.007,0.001,1423.133,0.059,0.075,0.0093,23946.177,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-05",15,13.94,3115.37,,0.007,0.001,1295.713,0.059,0.069,0.0093,21799.444,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-06",19,18.03,3623,,0.008,0.001,1520.008,0.0591,0.073,0.0065,25578.598,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-07",17,15,3106.87,,0.007,0.001,1305.872,0.059,0.068,0.0104,21972.857,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-08",18,17.33,3700.37,,0.008,0.001,1541.521,0.059,0.074,0.0064,25939.937,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-09",15,13.5,3093.75,,0.006,0.001,1285.802,0.0591,0.073,0.0097,21634.699,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-10",15,14.46,3308.56,,0.007,0.001,1388.791,0.059,0.071,0.0073,23367.047,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-11",15,13.92,3220.34,,0.007,0.001,1357.796,0.059,0.072,0.0094,22846.396,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-12",15,14.05,3188.35,,0.007,0.001,1338.782,0.059,0.07,0.0089,22528.686,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-13",19,17.64,4040.12,,0.008,0.001,1682.091,0.059,0.08,0.0072,28303.349,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-14",15,13.97,2762.33,,0.006,0.001,1166.932,0.059,0.062,0.009,19633.527,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-15",15,13.9,2421.02,,0.005,0.001,1053.662,0.059,0.056,0.0085,17732.628,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-16",19,17.42,3410.8,,0.007,0.001,1436.849,0.059,0.071,0.008,24180.381,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-17",20,18.29,3760.57,,0.008,0.001,1573.952,0.059,0.074,0.0072,26488.566,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-18",14,12.83,3077.36,,0.006,0.001,1268.802,0.059,0.072,0.0107,21351.744,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-19",14,12.8,2486.06,,0.005,0.001,1044.062,0.059,0.065,0.0124,17564.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-20",15,13.8,2911.42,,0.006,0.001,1207.464,0.059,0.06,0.008,20317.304,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-21",9,7.97,1854.42,,0.004,0.001,780.446,0.059,0.045,0.0109,13133.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-22",20,18.59,4159.75,,0.009,0.001,1725.515,0.0591,0.083,0.006,29035.953,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-23",7,6.57,1388.34,,0.003,0.001,587.031,0.059,0.042,0.0154,9878.539,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-24",2,1.33,241.26,,0.001,0.001,102.493,0.059,0.005,0.008,1723.916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-26",16,13.27,2950.44,,0.006,0.001,1221.76,0.0591,0.081,0.0366,20560.534,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-27",24,23.32,4731.72,,0.01,0.001,1968.64,0.059,0.083,0.0053,33124.528,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-28",19,17.4,3801.32,,0.008,0.001,1575.204,0.059,0.076,0.0082,26507.501,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-29",20,18.4,4040.87,,0.009,0.001,1687.963,0.0591,0.082,0.0068,28401.911,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-30",15,14.5,3301.5,,0.007,0.001,1396.65,0.059,0.07,0.0089,23497.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-07-31",24,23.35,4909.3,,0.01,0.001,2052.4,0.059,0.089,0.0053,34531.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-01",19,18.33,3635.56,,0.008,0.001,1522.276,0.059,0.071,0.006,25615.161,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-02",16,14.45,2975.75,,0.006,0.001,1244.148,0.059,0.062,0.0092,20934.956,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-03",15,14.05,2899.22,,0.006,0.001,1221.882,0.059,0.062,0.0075,20561.035,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-04",15,14.08,2728.34,,0.006,0.001,1147.51,0.059,0.063,0.0091,19311.332,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-05",15,14.07,3176.07,,0.007,0.001,1314.787,0.059,0.076,0.0099,22123.364,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-06",24,23.32,5448.36,,0.011,0.001,2242.136,0.059,0.096,0.0053,37724.872,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-07",15,14.27,3059.94,,0.007,0.001,1289.31,0.059,0.066,0.0074,21695.978,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-08",15,14.58,3232.1,,0.007,0.001,1346.24,0.059,0.071,0.0092,22649.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-09",20,18.47,4268.6,,0.009,0.001,1745.864,0.059,0.082,0.0076,29375.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-10",24,23.4,5643.2,,0.012,0.001,2300.68,0.059,0.098,0.0053,38714.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-11",19,18.07,3831,,0.008,0.001,1581.013,0.059,0.075,0.0078,26604.027,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-12",24,24,5663,,0.012,0.001,2314.6,0.059,0.097,0.005,38950,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-13",19,17.8,3934.18,,0.008,0.001,1651.494,0.059,0.079,0.0065,27789.428,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-14",19,18.32,4174.36,,0.009,0.001,1758.436,0.059,0.082,0.0096,29592.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-15",24,24,5601,,0.012,0.001,2320.9,0.059,0.098,0.005,39055.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-16",19,17.75,3347.09,,0.007,0.001,1421.054,0.059,0.07,0.0079,23911.718,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-17",19,17.94,3828.12,,0.008,0.001,1646.304,0.059,0.079,0.0076,27701.466,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-18",24,24,4955,,0.011,0.001,2097.2,0.059,0.087,0.005,35287,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-19",24,24,4896,,0.01,0.001,2049.5,0.059,0.085,0.0049,34486.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-20",24,23.23,4663.07,,0.01,0.001,1959.969,0.059,0.085,0.0053,32981.165,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-21",16,15.05,3377.13,,0.007,0.001,1403.971,0.059,0.068,0.0073,23623.311,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-22",16,15.55,3545.85,,0.007,0.001,1474.665,0.059,0.071,0.0078,24815.485,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-23",16,14.63,3392.73,,0.007,0.001,1423.472,0.059,0.074,0.0084,23954.141,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-24",16,15.3,3435.52,,0.007,0.001,1435.84,0.059,0.068,0.007,24160.63,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-25",16,15.42,3456.38,,0.007,0.001,1449.2,0.059,0.068,0.0083,24386.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-26",24,24,4989,,0.01,0.001,2062.2,0.059,0.088,0.0051,34702.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-27",24,24,4872,,0.01,0.001,2048.6,0.059,0.086,0.005,34468.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-28",24,24,4625,,0.01,0.001,1940.2,0.059,0.082,0.005,32647,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-29",24,23.4,4162,,0.009,0.001,1745.62,0.059,0.074,0.0052,29372.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-30",14,12.96,2405.66,,0.005,0.001,1007.296,0.059,0.063,0.0111,16953.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-08-31",15,13.89,2506.94,,0.005,0.001,1056.388,0.059,0.054,0.0079,17775.427,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-01",20,19.2,3800.8,,0.008,0.001,1598,0.059,0.075,0.0087,26885.08,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-02",20,18.43,3783.63,,0.008,0.001,1579.811,0.059,0.076,0.0065,26587.059,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-03",24,24,4325,,0.009,0.001,1835.6,0.059,0.077,0.005,30886.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-04",24,23.43,4652.62,,0.01,0.001,1954.681,0.059,0.083,0.0053,32887.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-05",19,18.07,4274.07,,0.009,0.001,1810.759,0.059,0.084,0.0069,30471.202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-06",24,24,5718,,0.012,0.001,2388,0.059,0.102,0.0051,40181.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-07",17,15.85,2842.01,,0.006,0.001,1211.502,0.059,0.065,0.0083,20384.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-08",15,14.58,2612.1,,0.006,0.001,1109.556,0.059,0.059,0.0085,18669.054,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-09",24,23.42,5143.64,,0.011,0.001,2140.232,0.059,0.092,0.0053,36016.028,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-10",15,14.55,2672.85,,0.006,0.001,1127.83,0.059,0.061,0.0089,18978.505,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-11",24,24,5843,,0.012,0.001,2377.7,0.059,0.099,0.005,40009.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-12",24,24,5553,,0.011,0.001,2270.7,0.059,0.095,0.005,38211.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-13",19,18.67,4187.43,,0.009,0.001,1723.917,0.059,0.073,0.005,29012.362,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-14",12,12,2824,,0.006,0.001,1174.8,0.059,0.07,0.0088,19767.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-15",24,24,5438,,0.011,0.001,2228.3,0.059,0.094,0.005,37496.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-16",17,14.39,3121.02,,0.007,0.001,1302.617,0.059,0.067,0.0105,21918.792,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-18",14,13.88,1987.08,,0.004,0.001,881.768,0.059,0.088,0.0184,14837.912,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-19",24,24,3633,,0.008,0.001,1578.9,0.059,0.066,0.005,26565.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-20",3,2.62,369.58,,0.001,0.001,168.786,0.059,0.008,0.0063,2839.866,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-24",15,14.33,2827.63,,0.006,0.001,1182.937,0.0591,0.111,0.0249,19907.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-25",24,24,4930,,0.01,0.001,2014.9,0.059,0.084,0.005,33906.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-26",18,16.9,3149.6,,0.007,0.001,1324.938,0.059,0.066,0.0078,22296.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-27",24,24,5009,,0.01,0.001,2051.9,0.059,0.086,0.005,34529.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-28",24,24,5218,,0.011,0.001,2159.4,0.059,0.093,0.0051,36334.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-29",24,24,5562,,0.012,0.001,2290.3,0.059,0.096,0.005,38537.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-09-30",20,19.31,4347.79,,0.009,0.001,1829.455,0.059,0.086,0.0064,30780.61,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-01",24,24,5336,,0.011,0.001,2210.9,0.059,0.092,0.005,37202.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-02",24,24,5253,,0.011,0.001,2150.7,0.059,0.09,0.005,36191.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-03",24,24,4819,,0.01,0.001,1975.2,0.059,0.083,0.005,33238.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-04",24,24,5066,,0.01,0.001,2067.9,0.059,0.087,0.005,34799.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-05",24,24,4862,,0.01,0.001,2026.6,0.059,0.085,0.005,34101.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-06",24,24,5719,,0.012,0.001,2338.2,0.059,0.098,0.005,39341.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-07",24,24,5763,,0.012,0.001,2368.8,0.059,0.1,0.005,39859.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-08",24,24,5853,,0.012,0.001,2396.3,0.059,0.101,0.005,40323.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-09",24,24,5839,,0.012,0.001,2389.6,0.059,0.101,0.005,40214.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-10",24,24,5850,,0.012,0.001,2401.1,0.059,0.103,0.0051,40410.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-11",19,17.41,3608.08,,0.008,0.001,1508.116,0.0591,0.072,0.0065,25379.222,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-12",24,24,5357,,0.011,0.001,2195.2,0.059,0.092,0.005,36942.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-13",24,24,5839,,0.012,0.001,2409.8,0.059,0.101,0.005,40550.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-14",24,24,5267,,0.011,0.001,2184,0.059,0.094,0.0051,36749.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-15",24,24,5446,,0.011,0.001,2230.9,0.059,0.097,0.0052,37542.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-16",24,23.5,5730,,0.012,0.001,2354.15,0.059,0.101,0.0053,39610.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-17",2,0.13,0.05,,0,0.001,3.326,0.059,0.005,0.188,55.966,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-30",3,0.44,5.09,,0,0.001,13.689,0.0593,0.02,0.1357,230.263,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-10-31",16,14.75,2188.1,,0.005,0.001,1016.385,0.059,0.174,0.0422,17102.155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-01",22,21.32,4754.44,,0.01,0.001,1965.244,0.059,0.093,0.0087,33066.836,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-02",24,24,5729,,0.012,0.001,2309.6,0.059,0.097,0.005,38862.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-03",24,24,5478,,0.011,0.001,2234.9,0.059,0.093,0.005,37601.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-04",24,24,5515,,0.011,0.001,2231,0.059,0.094,0.005,37542.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-05",24,24,5662,,0.012,0.001,2311.9,0.059,0.097,0.005,38905.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-06",24,24,5158,,0.011,0.001,2110.4,0.059,0.09,0.0051,35514.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-07",24,24,5841,,0.012,0.001,2399.6,0.059,0.101,0.005,40376.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-08",6,5.38,1245.18,,0.003,0.001,513.634,0.059,0.023,0.0063,8641.994,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-09",14,13.07,2530,,0.005,0.001,1059.95,0.059,0.07,0.0146,17833.798,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-10",24,24,5554,,0.011,0.001,2239.7,0.059,0.094,0.005,37689.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-11",24,24,5314,,0.011,0.001,2160.8,0.059,0.091,0.005,36358,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-12",24,24,5255,,0.011,0.001,2143.1,0.059,0.09,0.005,36061,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-13",9,8.47,1813.15,,0.004,0.001,738.723,0.059,0.033,0.0057,12430.768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-14",1,0.72,25.2,,0,0.001,27.648,0.059,0.029,0.125,464.832,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-15",24,24,4872,,0.01,0.001,1987.4,0.059,0.088,0.0053,33442.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-16",24,24,5143,,0.011,0.001,2088.1,0.059,0.087,0.005,35129.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-17",24,24,5006,,0.01,0.001,2034.8,0.059,0.086,0.005,34243,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-18",24,24,5058,,0.011,0.001,2117,0.059,0.089,0.005,35626.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-19",15,14,2697.25,,0.006,0.001,1143.48,0.059,0.068,0.011,19241.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-20",24,24,5347,,0.011,0.001,2163.6,0.059,0.09,0.005,36403.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-21",24,24,5529,,0.011,0.001,2244.5,0.059,0.094,0.005,37766.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-22",24,24,5162,,0.011,0.001,2097.2,0.059,0.088,0.005,35284.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-23",13,11.81,2155.14,,0.005,0.001,911.767,0.059,0.051,0.0094,15343.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-24",24,24,5596,,0.012,0.001,2283.3,0.059,0.096,0.005,38418.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-25",24,24,5241,,0.011,0.001,2136.7,0.059,0.09,0.005,35957,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-26",17,16.17,3783.02,,0.008,0.001,1550.412,0.059,0.075,0.0074,26088.664,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-27",24,24,4807,,0.01,0.001,1979.8,0.059,0.083,0.005,33315.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-28",17,16.07,3523.29,,0.007,0.001,1455.78,0.059,0.088,0.0118,24497.765,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-29",17,16.02,3568.78,,0.007,0.001,1470.852,0.059,0.087,0.0112,24749.536,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-11-30",24,24,5350,,0.011,0.001,2175.7,0.059,0.092,0.005,36613.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-01",24,24,5281,,0.011,0.001,2174.8,0.059,0.091,0.005,36592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-02",24,24,4990,,0.01,0.001,2063.2,0.059,0.086,0.005,34721,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-03",24,24,5178,,0.011,0.001,2136.4,0.059,0.09,0.005,35948.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-04",24,24,5315,,0.011,0.001,2205,0.059,0.093,0.005,37102,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-05",24,24,5403,,0.011,0.001,2205.5,0.059,0.093,0.005,37111.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-06",24,24,5135,,0.011,0.001,2108.9,0.059,0.089,0.005,35486.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-07",24,24,5498,,0.011,0.001,2241.8,0.059,0.094,0.005,37718.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-08",24,24,4707,,0.01,0.001,1949.9,0.059,0.082,0.005,32805.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-09",24,24,5074,,0.011,0.001,2101.9,0.059,0.088,0.005,35369,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-10",23,22.4,4698.2,,0.01,0.001,1932.8,0.059,0.083,0.0053,32523.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-11",19,18.62,4068.5,,0.008,0.001,1668.988,0.059,0.08,0.0069,28083.454,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-12",24,24,5308,,0.011,0.001,2173.6,0.059,0.091,0.005,36574.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-13",24,24,5701,,0.012,0.001,2314.4,0.059,0.097,0.005,38944.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-14",24,24,5075,,0.011,0.001,2092.5,0.059,0.088,0.005,35208.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-15",24,24,5334,,0.011,0.001,2182.9,0.059,0.092,0.005,36730.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-16",24,24,5450,,0.011,0.001,2227.2,0.059,0.094,0.005,37477.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-17",24,24,4773,,0.01,0.001,1973.3,0.059,0.083,0.005,33202.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-18",24,24,5039,,0.011,0.001,2086.9,0.059,0.088,0.005,35115.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-19",24,24,4911,,0.01,0.001,2030.8,0.059,0.085,0.005,34173,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-20",1,0.45,78.3,,0,0.001,32.985,0.059,0.003,0.011,554.805,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-22",24,23.55,4353.25,,0.009,0.001,1876.855,0.0591,0.188,0.0239,31581.65,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-23",24,24,4910,,0.01,0.001,2031.4,0.059,0.085,0.005,34184.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-24",24,24,5034,,0.01,0.001,2065.8,0.059,0.087,0.005,34760.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-25",11,10.38,1650.56,,0.004,0.001,743.168,0.059,0.052,0.01,12507.098,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-26",17,15.81,2642.22,,0.006,0.001,1138.103,0.059,0.058,0.0078,19152.078,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-27",24,24,4543,,0.01,0.001,1884.9,0.059,0.079,0.005,31718.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-28",24,24,5049,,0.01,0.001,2066,0.059,0.087,0.005,34764.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-29",24,24,4933,,0.01,0.001,2025.8,0.059,0.085,0.005,34089.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-30",24,24,4847,,0.01,0.001,2002.9,0.059,0.084,0.005,33698.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Palomar Energy Center",55985,"CTG2",,"2020-12-31",24,24,4999,,0.01,0.001,2051.3,0.059,0.086,0.005,34518.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-02",1,0.17,0,,0,0.001,0.901,0.059,0.001,0.13,15.215,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-07",6,4.85,91.18,,0,0.001,66.603,0.0595,0.021,0.0637,1119.982,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-08",3,2.43,44.73,,0,0.001,33.212,0.059,0.006,0.0343,558.633,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-09",6,4.21,103,,0,0.001,68.613,0.0592,0.009,0.035,1153.719,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-10",5,3.78,94.12,,0,0.001,63.285,0.0594,0.008,0.0248,1065.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-11",12,10.9,330,,0.001,0.001,207.998,0.0593,0.015,0.0123,3497.808,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-12",4,2.3,27.78,,0,0.0008,24.734,0.059,0.008,0.0295,416.586,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-13",4,2.38,24,,0,0.001,23.26,0.0595,0.007,0.0478,391.934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-28",11,9.7,286.04,,0.001,0.001,182.031,0.0595,0.031,0.0352,3063.255,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-29",11,9.55,374.5,,0.001,0.001,222.61,0.0595,0.019,0.0234,3743.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-01-31",7,5.32,131.2,,0,0.001,87.386,0.0593,0.011,0.038,1470.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-04",6,4.86,143.86,,0,0.001,91.336,0.0592,0.018,0.0467,1537.334,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-17",7,6.5,229,,0.001,0.001,138.15,0.059,0.023,0.0441,2325.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-18",7,5.65,183,,0.001,0.001,113.889,0.0596,0.014,0.0277,1915.946,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-04",5,3.26,86.08,,0,0.001,55.974,0.0596,0.013,0.0628,940.632,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-05",19,17.36,705.31,,0.002,0.001,406.764,0.0592,0.022,0.0083,6848.788,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-06",13,11.95,470.6,,0.001,0.001,277.246,0.0592,0.017,0.0115,4664.286,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-07",14,12.48,517.72,,0.002,0.001,302.328,0.0593,0.017,0.0126,5088.089,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-08",15,14.65,634.5,,0.002,0.001,344.205,0.0592,0.021,0.0103,5790.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-09",16,14.14,620.82,,0.002,0.001,343.312,0.0591,0.024,0.0161,5778.369,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-10",17,15.49,750.27,,0.002,0.001,370.328,0.0591,0.022,0.0103,6233.165,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-11",18,16.15,766.04,,0.002,0.001,382.967,0.0592,0.022,0.0099,6443.703,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-12",18,16.32,915.23,,0.002,0.001,444.377,0.0592,0.025,0.0097,7475.059,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-16",11,10.73,495.76,,0.001,0.001,243.565,0.0595,0.018,0.0133,4098.807,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-17",15,13.57,647.72,,0.002,0.001,314.308,0.0591,0.019,0.0111,5290.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-18",24,24,1421,,0.003,0.001,652.5,0.0591,0.033,0.006,10975.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-19",18,16.31,703.11,,0.002,0.001,375.858,0.0592,0.022,0.0116,6323.613,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-20",14,12.15,561.1,,0.001,0.001,278.03,0.0595,0.018,0.0165,4675.57,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-21",13,12.3,564.82,,0.001,0.001,273.752,0.0591,0.019,0.0171,4607.008,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-22",18,16.27,762.5,,0.002,0.001,361.079,0.0591,0.022,0.0106,6076.437,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-23",18,16.23,783.2,,0.002,0.001,370.093,0.0593,0.023,0.0132,6227.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-24",24,24,1350,,0.003,0.001,600.1,0.0591,0.03,0.006,10098.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-25",20,18.77,954.17,,0.002,0.001,443.885,0.0593,0.026,0.0109,7467.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-26",24,24,1337,,0.003,0.001,594.3,0.0593,0.028,0.0056,9999,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-27",15,14.08,684.24,,0.002,0.001,319.512,0.0593,0.019,0.0119,5376.244,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-28",12,11.24,480.1,,0.001,0.001,227.714,0.0593,0.016,0.0193,3831.459,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-29",15,14.3,688.55,,0.002,0.001,314.946,0.0592,0.02,0.0141,5299.255,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-06-30",24,24,1338,,0.003,0.001,592.8,0.0593,0.03,0.006,9976.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-01",24,24,1392,,0.003,0.001,638.9,0.0592,0.032,0.006,10753.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-02",24,20.39,1029.36,,0.002,0.001,491.682,0.0593,0.029,0.012,8272.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-03",21,19.54,953.36,,0.002,0.001,453.672,0.0593,0.027,0.0138,7632.906,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-04",15,13.56,647.51,,0.002,0.001,321.038,0.0591,0.02,0.015,5400.622,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-05",18,16.52,808.04,,0.002,0.001,397.392,0.0593,0.025,0.0142,6686.008,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-06",24,24,1391,,0.003,0.001,629.5,0.0593,0.032,0.006,10593.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-07",23,21.5,1138.9,,0.003,0.001,537.61,0.0592,0.03,0.0092,9050.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-08",1,0.25,4,,0,0.001,2.7,0.059,0,0.009,45.425,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-09",16,14.95,779.01,,0.002,0.001,367.991,0.0593,0.027,0.0159,6191.124,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-12",12,11.2,639,,0.001,0.001,294.42,0.0593,0.02,0.0212,4950.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-13",24,24,1405,,0.003,0.001,633.8,0.0594,0.032,0.006,10660.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-14",24,24,1404,,0.003,0.001,636.4,0.0593,0.032,0.006,10704.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-15",24,24,1484,,0.003,0.001,667.7,0.0592,0.034,0.006,11233.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-16",24,24,1490,,0.003,0.001,672.3,0.0591,0.034,0.006,11316.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-17",24,24,1484,,0.003,0.001,673.9,0.0591,0.034,0.006,11340.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-18",24,24,1431,,0.003,0.001,649.8,0.0592,0.033,0.006,10936.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-19",23,21.35,1133.54,,0.003,0.001,539.609,0.0591,0.03,0.0099,9082.059,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-20",24,24,1478,,0.003,0.001,674.6,0.0591,0.034,0.006,11354.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-21",24,24,1492,,0.003,0.001,670.8,0.0591,0.034,0.006,11288.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-22",24,24,1482,,0.003,0.001,664,0.0593,0.034,0.006,11171.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-23",24,24,1502,,0.003,0.001,673.3,0.0593,0.034,0.006,11327.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-24",24,24,1445,,0.003,0.001,671,0.0591,0.034,0.006,11293.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-25",24,24,1393,,0.003,0.001,634.3,0.0592,0.032,0.006,10673.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-26",20,19.18,1066.18,,0.003,0.001,500.744,0.0591,0.027,0.0094,8425.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-27",24,24,1398,,0.003,0.001,633.7,0.0592,0.034,0.0064,10662.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-28",24,24,1569,,0.004,0.001,711.5,0.0591,0.038,0.0064,11969.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-29",24,24,1442,,0.003,0.001,654.9,0.0593,0.033,0.006,11018.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-30",24,24,1582,,0.004,0.001,747.1,0.0591,0.038,0.006,12571.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-07-31",24,24,1470,,0.003,0.001,666,0.0592,0.034,0.006,11207.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-01",24,24,1486,,0.003,0.001,674.4,0.0591,0.034,0.006,11352.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-02",24,24,1420,,0.003,0.001,639.6,0.0593,0.032,0.006,10758.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-03",24,24,1519,,0.004,0.001,708,0.0592,0.036,0.006,11912.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-04",20,19,1000.8,,0.002,0.001,475.16,0.0592,0.028,0.0124,7997.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-05",24,24,1431,,0.003,0.001,632.7,0.0593,0.032,0.006,10644.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-06",24,24,1434,,0.003,0.001,635.3,0.0591,0.032,0.006,10690,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-07",24,24,1441,,0.003,0.001,640.3,0.0591,0.033,0.006,10772.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-08",23,21.57,1246.5,,0.003,0.001,559.207,0.0591,0.029,0.0077,9410.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-09",22,21.23,1143.69,,0.003,0.001,525.395,0.0593,0.028,0.0087,8838.701,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-10",24,24,1443,,0.003,0.001,637.9,0.0593,0.032,0.006,10734.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-11",24,24,1445,,0.003,0.001,645.4,0.0592,0.033,0.006,10857.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-12",24,24,1462,,0.003,0.001,650.1,0.0592,0.033,0.006,10938.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-13",24,24,1536,,0.004,0.001,699.4,0.0591,0.035,0.006,11769.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-14",24,24,1531,,0.004,0.001,696.7,0.0592,0.035,0.006,11722.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-15",24,24,1525,,0.004,0.001,694.1,0.0592,0.035,0.006,11680.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-16",24,24,1562,,0.004,0.001,718.3,0.0592,0.036,0.006,12088.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-17",24,24,1549,,0.004,0.001,710.1,0.0593,0.036,0.006,11948.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-18",24,24,1537,,0.004,0.001,702.4,0.0592,0.035,0.006,11817,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-19",24,24,1461,,0.003,0.001,657.7,0.0592,0.033,0.006,11067.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-20",24,24,1484,,0.003,0.001,668.5,0.059,0.034,0.006,11249.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-21",24,24,1512,,0.003,0.001,682.1,0.0591,0.034,0.006,11479.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-22",24,24,1497,,0.003,0.001,670.2,0.0591,0.034,0.006,11280,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-23",24,24,1516,,0.003,0.001,683.7,0.059,0.035,0.006,11509.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-24",24,24,1510,,0.003,0.001,681.3,0.0592,0.034,0.006,11466.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-25",24,24,1504,,0.003,0.001,676.6,0.0591,0.034,0.006,11385.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-26",8,7.03,423.83,,0.001,0.001,187.216,0.0591,0.009,0.006,3150.537,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-28",11,10.03,457,,0.001,0.001,228.408,0.0593,0.02,0.0168,3843.609,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-29",24,24,1393,,0.003,0.001,631.6,0.0591,0.032,0.006,10632,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-30",24,24,1435,,0.003,0.001,642.5,0.0592,0.032,0.006,10811.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-08-31",24,24,1512,,0.003,0.001,677.7,0.0591,0.034,0.006,11405.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-01",24,24,1398,,0.003,0.001,625.8,0.0592,0.032,0.006,10531.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-02",24,24,1456,,0.003,0.001,664.7,0.0592,0.034,0.006,11182.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-03",24,24,1498,,0.003,0.001,692,0.059,0.035,0.006,11648.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-04",24,24,1487,,0.003,0.001,662.2,0.059,0.033,0.006,11144.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-05",24,24,1471,,0.003,0.001,662.4,0.0592,0.033,0.006,11143.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-06",24,24,1454,,0.003,0.001,656.7,0.0591,0.033,0.006,11054.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-07",24,24,1486,,0.003,0.001,670.1,0.0592,0.034,0.006,11275.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-08",24,24,1440,,0.003,0.001,650.1,0.0593,0.033,0.006,10939.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-09",24,24,1484,,0.003,0.001,666.6,0.0592,0.034,0.006,11216.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-10",24,24,1312,,0.003,0.001,658.7,0.0593,0.033,0.006,11080,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-11",24,24,1185,,0.003,0.001,678.6,0.0592,0.034,0.006,11417.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-12",2,1.07,33,,0,0.001,20.871,0.0595,0.001,0.011,350.765,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-14",4,3.32,56.32,,0,0.001,43.52,0.0595,0.006,0.0388,731.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-15",24,24,1506,,0.004,0.001,693.2,0.0591,0.035,0.006,11667.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-16",24,24,1504,,0.003,0.001,680.3,0.0591,0.034,0.006,11449.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-17",24,24,1509,,0.003,0.001,687.4,0.0591,0.035,0.006,11567.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-18",24,24,1542,,0.004,0.001,696.4,0.0591,0.035,0.006,11721.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-19",24,24,1482,,0.003,0.001,677.8,0.0593,0.034,0.006,11404.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-20",24,24,1498,,0.003,0.001,677.1,0.0593,0.034,0.006,11389.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-21",24,24,1489,,0.003,0.001,675.8,0.0593,0.034,0.006,11369,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-22",24,24,1509,,0.003,0.001,682.2,0.059,0.034,0.006,11482.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-23",24,24,1480,,0.003,0.001,678,0.0593,0.032,0.0055,11405.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-24",24,24,1511,,0.003,0.001,685.9,0.059,0.035,0.006,11541.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-25",24,24,1464,,0.003,0.001,664.1,0.0592,0.033,0.006,11174.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-26",24,24,1493,,0.003,0.001,679.1,0.0591,0.034,0.006,11425.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-27",24,24,1508,,0.003,0.001,692.1,0.059,0.035,0.006,11651.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-28",24,24,1461,,0.003,0.001,669.9,0.059,0.034,0.006,11275.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-29",24,24,1490,,0.003,0.001,684.4,0.0592,0.035,0.006,11514.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-09-30",24,24,1531,,0.004,0.001,698,0.0591,0.035,0.006,11744.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-01",24,24,1534,,0.003,0.001,688,0.0592,0.035,0.006,11572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-02",24,24,1533,,0.003,0.001,691.2,0.0592,0.035,0.006,11626.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-03",24,24,1525,,0.003,0.001,688.7,0.059,0.035,0.006,11589.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-04",24,24,1500,,0.003,0.001,683.3,0.059,0.034,0.006,11496.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-05",24,24,1502,,0.003,0.001,687.8,0.0593,0.035,0.006,11573.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-06",24,24,1489,,0.003,0.001,678.7,0.0593,0.034,0.006,11418.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-07",24,24,1380,,0.003,0.001,628.8,0.059,0.032,0.006,10585.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-08",24,24,1470,,0.003,0.001,646.7,0.0591,0.033,0.006,10887.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-09",24,24,1500,,0.003,0.001,679.2,0.0592,0.034,0.006,11430.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-10",24,24,1395,,0.003,0.001,626.8,0.0593,0.032,0.006,10545,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-11",24,24,1362,,0.003,0.001,614.7,0.0591,0.031,0.006,10347.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-12",24,24,1506,,0.003,0.001,687.7,0.0591,0.035,0.006,11573,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-13",24,24,1494,,0.003,0.001,682.1,0.0592,0.034,0.006,11478.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-14",24,24,1493,,0.003,0.001,673.3,0.0592,0.034,0.006,11326.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-15",24,24,1510,,0.003,0.001,663,0.0591,0.033,0.006,11158.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-16",24,24,1482,,0.003,0.001,661.3,0.0591,0.033,0.006,11130.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-17",24,24,1493,,0.003,0.001,671.9,0.0591,0.034,0.006,11304.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-18",24,24,1504,,0.003,0.001,669.2,0.0591,0.034,0.006,11263.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-19",24,24,1501,,0.003,0.001,677.8,0.0593,0.034,0.006,11400.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-20",24,24,1473,,0.003,0.001,661.5,0.0591,0.033,0.006,11131.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-21",24,24,1490,,0.003,0.001,662.1,0.0591,0.033,0.006,11142.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-22",24,24,1458,,0.003,0.001,642.8,0.0592,0.032,0.006,10818.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-23",22,21.05,1225.15,,0.003,0.001,532.26,0.0592,0.027,0.0064,8954.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-24",1,0.18,0.36,,0,0.001,1.008,0.06,0.001,0.137,16.848,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-25",11,10.38,512.14,,0.001,0.001,246.422,0.0592,0.014,0.0115,4147.114,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-26",24,24,1479,,0.003,0.001,658.9,0.0592,0.033,0.006,11089.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-27",24,24,1474,,0.003,0.001,649.3,0.0593,0.033,0.006,10923.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-28",24,24,1475,,0.003,0.001,646.4,0.0591,0.033,0.006,10881.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-29",24,24,1455,,0.003,0.001,637.1,0.0592,0.032,0.006,10719.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-30",24,24,1477,,0.003,0.001,651,0.0591,0.033,0.006,10955.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-10-31",23,21.53,1245.94,,0.003,0.001,549.749,0.0592,0.028,0.0064,9250.789,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-19",9,8.04,404.16,,0.001,0.001,193.286,0.0593,0.023,0.0462,3250.326,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-20",9,8.2,401,,0.001,0.001,211.16,0.0592,0.016,0.0252,3552.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-21",24,24,1454,,0.003,0.001,683.5,0.0592,0.035,0.006,11501.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-22",24,24,1492,,0.003,0.001,664.8,0.0593,0.034,0.006,11185.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-23",24,24,1431,,0.003,0.001,627.9,0.0591,0.032,0.006,10565.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-24",24,24,1453,,0.003,0.001,644.1,0.0593,0.033,0.006,10839,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-25",24,24,1446,,0.003,0.001,640.2,0.0593,0.032,0.006,10771.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-26",24,24,1533,,0.003,0.001,674.1,0.0593,0.034,0.006,11340,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-27",24,24,1519,,0.003,0.001,674.5,0.0591,0.034,0.006,11352.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-28",24,24,1470,,0.003,0.001,661.6,0.0592,0.033,0.006,11127.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-29",24,24,1461,,0.003,0.001,660.7,0.0591,0.033,0.006,11115.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-11-30",24,24,1496,,0.003,0.001,672.4,0.0594,0.034,0.006,11309.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-01",24,24,1517,,0.003,0.001,682.4,0.0593,0.034,0.006,11479.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-02",24,24,1524,,0.003,0.001,685.9,0.0592,0.035,0.006,11539.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-03",24,24,1548,,0.004,0.001,694.4,0.059,0.035,0.006,11684.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-04",24,24,1503,,0.003,0.001,674.4,0.059,0.034,0.006,11351.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-05",24,24,1536,,0.003,0.001,684.3,0.0591,0.035,0.006,11511.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-06",24,24,1527,,0.003,0.001,684,0.059,0.035,0.006,11515.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-07",24,24,1495,,0.003,0.001,666.6,0.0592,0.03,0.0053,11215.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-08",24,24,1533,,0.003,0.001,676.2,0.0591,0.034,0.006,11378.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-09",24,24,1520,,0.003,0.001,670.5,0.0593,0.034,0.006,11278.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-10",24,24,1492,,0.003,0.001,658.9,0.059,0.033,0.006,11087.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-11",24,24,1548,,0.003,0.001,685.3,0.0591,0.035,0.006,11532.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-12",24,24,1537,,0.003,0.001,682,0.0593,0.034,0.006,11469.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-13",24,24,1534,,0.003,0.001,681.9,0.059,0.034,0.006,11477.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-14",24,24,1472,,0.003,0.001,651.5,0.0591,0.033,0.006,10963.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-15",24,24,1495,,0.003,0.001,664,0.0593,0.034,0.006,11171.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-16",24,24,1508,,0.003,0.001,665.7,0.0593,0.034,0.006,11197.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-17",24,24,1509,,0.003,0.001,666.9,0.0592,0.034,0.006,11222.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-18",24,24,1522,,0.003,0.001,671.7,0.0591,0.034,0.006,11301.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-19",24,24,1516,,0.003,0.001,671.2,0.0592,0.034,0.006,11292.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-20",24,24,1476,,0.003,0.001,654.4,0.0591,0.033,0.006,11013.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-21",24,24,1463,,0.003,0.001,647.8,0.0593,0.033,0.006,10898.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-22",24,24,1484,,0.003,0.001,656.4,0.0591,0.033,0.006,11044.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-23",24,24,1520,,0.003,0.001,672.7,0.059,0.034,0.006,11322.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-24",24,24,1488,,0.003,0.001,661.5,0.0591,0.033,0.006,11132.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-25",24,24,1480,,0.003,0.001,655.2,0.0592,0.033,0.006,11023.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-26",20,19.6,1102.6,,0.003,0.001,503.12,0.0591,0.028,0.0091,8470.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-27",24,24,1523,,0.003,0.001,673.6,0.0592,0.034,0.006,11335.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-28",24,24,1502,,0.003,0.001,667.7,0.0592,0.034,0.006,11236.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-29",24,24,1504,,0.003,0.001,667.1,0.0593,0.034,0.006,11222.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-30",24,24,1492,,0.003,0.001,662.4,0.0593,0.033,0.006,11141.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT1",,"2020-12-31",24,24,1495,,0.003,0.001,662.6,0.0593,0.033,0.006,11147.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-01",24,24,961,,0.003,0.001,586.9,0.0592,0.042,0.0103,9877.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-02",1,0.08,0,,0,0.001,0.44,0.059,0,0.014,7.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-08",7,5.86,174.48,,0.001,0.001,115.596,0.0593,0.026,0.06,1943.942,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-09",5,3.53,97.35,,0,0.001,65.29,0.0594,0.009,0.037,1098.46,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-10",5,4.34,95.74,,0,0.001,68.898,0.0592,0.016,0.0576,1160.057,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-11",12,8.97,210.1,,0.001,0.001,148.326,0.0593,0.018,0.0339,2495.869,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-12",4,2.3,27.78,,0,0.0008,25.527,0.0593,0.009,0.048,430.166,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-13",4,2.38,24,,0,0.001,24.066,0.06,0.011,0.065,403.378,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-28",11,10.25,305.2,,0.001,0.001,200.725,0.0594,0.041,0.0497,3376.49,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-30",12,10.63,426.6,,0.001,0.001,262.602,0.0591,0.029,0.0256,4422.853,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-19",1,0.27,0,,0,0.001,1.485,0.06,0.002,0.18,24.921,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-20",6,4.6,92.27,,0,0.001,69.603,0.0592,0.015,0.0542,1171.658,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-05",16,13.42,550.98,,0.002,0.001,338.27,0.0596,0.032,0.0267,5688.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-06",13,12,493.8,,0.002,0.001,304.5,0.0591,0.02,0.0155,5123.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-07",12,10.78,449,,0.001,0.001,274.218,0.0592,0.019,0.0167,4616.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-08",19,18.83,983.28,,0.003,0.001,527.007,0.0591,0.032,0.0091,8869.493,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-09",23,22.03,1163,,0.003,0.001,620.962,0.0592,0.032,0.0062,10447.106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-10",19,17.01,889.95,,0.002,0.001,452.264,0.0592,0.038,0.0121,7611.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-11",20,18.18,946,,0.002,0.001,470.157,0.0592,0.027,0.0098,7912.246,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-12",19,17.99,1005.35,,0.002,0.001,463.015,0.0592,0.026,0.0082,7791.563,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-16",11,10.73,556.49,,0.001,0.001,278.122,0.0593,0.02,0.0136,4679.152,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-17",16,14.54,723,,0.002,0.001,347.563,0.0592,0.025,0.0193,5851.486,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-18",24,24,1476,,0.003,0.001,658.5,0.0592,0.033,0.006,11083.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-19",19,17.22,804.4,,0.002,0.001,430.934,0.0591,0.027,0.0137,7253.494,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-20",14,12.13,597,,0.001,0.0009,294.08,0.0593,0.019,0.013,4946.282,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-21",12,11.83,591.5,,0.001,0.001,281.794,0.059,0.018,0.0109,4746.727,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-22",18,16.25,787.46,,0.002,0.001,381.705,0.0593,0.023,0.0127,6425.118,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-23",18,16.31,829.28,,0.002,0.001,393.389,0.059,0.025,0.0176,6624.227,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-24",24,24,1433,,0.003,0.001,654.2,0.0592,0.033,0.006,11011.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-25",21,19.7,1088.59,,0.003,0.001,524.089,0.0593,0.032,0.0136,8815.636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-26",24,24,1459,,0.003,0.001,673.7,0.0591,0.032,0.0057,11339,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-27",13,11.39,618.8,,0.001,0.001,291.031,0.0595,0.021,0.0192,4895.633,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-28",14,12.5,592.34,,0.001,0.001,288.032,0.059,0.02,0.0198,4848.872,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-29",18,16.5,833.89,,0.002,0.001,397.789,0.0593,0.025,0.0181,6693.676,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-06-30",24,24,1413,,0.003,0.001,649.3,0.059,0.033,0.0061,10929.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-01",24,24,1463,,0.003,0.001,692.6,0.0591,0.035,0.006,11656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-02",21,19.29,1037.65,,0.003,0.001,506.996,0.0593,0.03,0.0147,8526.985,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-03",21,19.5,1020.36,,0.003,0.001,504.03,0.0594,0.031,0.0163,8478.024,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-04",15,13.57,675.59,,0.002,0.001,341.531,0.0591,0.024,0.0231,5748.014,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-05",18,16.54,843.08,,0.002,0.001,422.094,0.0593,0.027,0.0171,7101.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-06",24,24,1456,,0.003,0.001,683.4,0.0591,0.034,0.006,11499.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-07",24,24,1390,,0.003,0.001,667.4,0.0592,0.034,0.006,11231,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-08",17,15.17,821.96,,0.002,0.001,407.167,0.0591,0.025,0.0113,6852.418,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-09",16,15.77,891.47,,0.002,0.001,439.685,0.0591,0.027,0.0106,7398.39,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-10",24,24,1464,,0.004,0.001,693.9,0.0591,0.035,0.006,11674.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-11",19,17.2,975.51,,0.002,0.001,468.072,0.0593,0.026,0.0089,7872.235,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-12",23,21.12,1236,,0.003,0.001,594.608,0.0592,0.033,0.0092,10007.909,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-13",24,24,1419,,0.003,0.001,665.2,0.0593,0.034,0.0061,11191.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-14",24,24,1401,,0.003,0.001,659,0.0591,0.033,0.006,11093.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-15",24,24,1505,,0.004,0.001,701.8,0.0592,0.035,0.006,11807.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-16",24,24,1497,,0.004,0.001,701.8,0.0592,0.035,0.006,11803.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-17",24,24,1504,,0.004,0.001,702.7,0.0591,0.035,0.006,11823.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-18",24,24,1451,,0.003,0.001,677.9,0.0592,0.035,0.0061,11407.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-19",23,21.41,1160.66,,0.003,0.001,569.794,0.0592,0.035,0.0148,9587.431,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-20",24,24,1502,,0.004,0.001,706.7,0.0591,0.036,0.006,11894.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-21",24,24,1515,,0.004,0.001,708.2,0.0592,0.036,0.006,11917.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-22",24,24,1529,,0.004,0.001,712.2,0.0591,0.036,0.006,11985.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-23",24,24,1536,,0.004,0.001,714.6,0.0592,0.036,0.006,12027.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-24",24,24,1482,,0.004,0.001,711.4,0.0591,0.036,0.006,11969,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-25",24,24,1415,,0.003,0.001,661.5,0.0592,0.033,0.006,11129.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-26",22,20.4,1172.8,,0.003,0.001,563.138,0.0592,0.031,0.0109,9476.486,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-27",24,24,1465,,0.003,0.001,681.8,0.0593,0.035,0.006,11473.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-28",24,24,1611,,0.004,0.001,754.8,0.0591,0.038,0.006,12701,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-29",24,24,1430,,0.003,0.001,669.1,0.0591,0.038,0.0067,11261,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-30",24,24,1620,,0.004,0.001,758,0.059,0.042,0.0066,12758.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-07-31",21,20.86,1253.54,,0.003,0.001,588.062,0.0591,0.031,0.0066,9895.618,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-01",24,24,1503,,0.004,0.001,702.4,0.0591,0.036,0.006,11820.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-02",10,9.52,487.61,,0.001,0.001,233.839,0.0591,0.016,0.012,3935.782,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-03",24,24,1485,,0.004,0.001,710.3,0.0592,0.036,0.0061,11953.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-04",22,21.16,1131.12,,0.003,0.001,570.895,0.0593,0.032,0.0095,9603.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-05",24,24,1447,,0.003,0.001,670.4,0.0591,0.034,0.006,11279.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-06",24,24,1451,,0.003,0.001,671.8,0.0591,0.034,0.006,11306.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-07",24,24,1459,,0.003,0.001,675.3,0.0591,0.034,0.006,11367.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-08",24,24,1466,,0.003,0.001,685.4,0.0592,0.035,0.006,11533.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-09",24,22.3,1239.9,,0.003,0.001,594.4,0.0591,0.031,0.0087,10003.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-10",24,24,1497,,0.003,0.001,689.8,0.0591,0.035,0.006,11607.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-11",24,24,1482,,0.003,0.001,687.6,0.0592,0.035,0.006,11567.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-12",24,24,1505,,0.004,0.001,697.4,0.0591,0.035,0.006,11740,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-13",24,24,1561,,0.004,0.001,725.3,0.0591,0.037,0.006,12202.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-14",24,24,1550,,0.004,0.001,714.1,0.0592,0.036,0.006,12019.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-15",24,24,1541,,0.004,0.001,709.2,0.0592,0.036,0.006,11933.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-16",24,24,1557,,0.004,0.001,731.3,0.0591,0.037,0.006,12304.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-17",24,24,1551,,0.004,0.001,727.4,0.0592,0.037,0.006,12237.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-18",24,24,1536,,0.004,0.001,722.3,0.0592,0.036,0.006,12154.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-19",24,24,1444,,0.003,0.001,680.3,0.0593,0.034,0.006,11445.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-20",24,24,1481,,0.003,0.001,692.5,0.0592,0.035,0.006,11652.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-21",24,24,1513,,0.004,0.001,707,0.0594,0.036,0.006,11889.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-22",24,24,1505,,0.004,0.001,695.9,0.059,0.035,0.006,11711.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-23",24,24,1516,,0.004,0.001,703.7,0.0592,0.036,0.006,11841.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-24",24,24,1516,,0.004,0.001,704.1,0.0591,0.036,0.006,11850.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-25",24,24,1502,,0.004,0.001,705.5,0.0592,0.036,0.006,11872.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-26",7,6.75,413,,0.001,0.001,191.7,0.059,0.01,0.006,3227.425,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-28",11,11,548,,0.001,0.001,276.5,0.059,0.022,0.0158,4654.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-29",24,24,1389,,0.003,0.001,641.5,0.0592,0.032,0.006,10792.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-30",24,24,1444,,0.003,0.001,665.7,0.0593,0.034,0.006,11200.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-08-31",24,24,1492,,0.004,0.001,696.9,0.0593,0.035,0.006,11724.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-01",24,24,1403,,0.003,0.001,648.6,0.0593,0.033,0.006,10911.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-02",24,24,1450,,0.003,0.001,683.7,0.0591,0.035,0.006,11505.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-03",24,24,1496,,0.004,0.001,713.6,0.0591,0.036,0.006,12007,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-04",24,24,1481,,0.004,0.001,693.5,0.0591,0.035,0.006,11671.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-05",24,24,1463,,0.003,0.001,678.7,0.0593,0.034,0.006,11420.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-06",24,24,1445,,0.003,0.001,673.6,0.0592,0.034,0.006,11336,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-07",24,24,1477,,0.003,0.001,681.6,0.0591,0.034,0.006,11468.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-08",24,24,1449,,0.003,0.001,668.8,0.0592,0.034,0.006,11249.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-09",24,24,1474,,0.003,0.001,684.4,0.0591,0.035,0.006,11520.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-10",24,24,1294,,0.003,0.001,688,0.0592,0.035,0.006,11576.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-11",24,24,1152,,0.004,0.001,696,0.059,0.035,0.006,11713.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-12",2,1.07,33,,0,0.001,21.985,0.059,0.001,0.0075,370.424,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-14",4,3.28,56.28,,0,0.001,44.936,0.0593,0.008,0.0518,756.236,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-15",24,24,1485,,0.004,0.001,699.2,0.0592,0.035,0.006,11763.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-16",24,24,1495,,0.004,0.001,702.8,0.0591,0.035,0.006,11826.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-17",24,24,1506,,0.004,0.001,698.8,0.0591,0.035,0.006,11756.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-18",24,24,1526,,0.004,0.001,703.4,0.0594,0.035,0.006,11827.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-19",24,24,1473,,0.003,0.001,685,0.0591,0.035,0.006,11524.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-20",24,24,1501,,0.004,0.001,693.5,0.0591,0.035,0.006,11670.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-21",24,24,1496,,0.003,0.001,689.9,0.0592,0.035,0.006,11606.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-22",24,24,1504,,0.004,0.001,693.9,0.0593,0.035,0.006,11672.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-23",24,24,1484,,0.003,0.001,691.5,0.0592,0.035,0.006,11637.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-24",24,24,1508,,0.004,0.001,696.7,0.0593,0.035,0.006,11724,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-25",24,24,1471,,0.003,0.001,681.1,0.0591,0.032,0.0056,11459.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-26",24,24,1494,,0.004,0.001,694.9,0.0591,0.035,0.006,11692.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-27",24,24,1503,,0.004,0.001,703.3,0.0593,0.035,0.006,11830.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-28",24,24,1450,,0.003,0.001,686.1,0.059,0.035,0.006,11549.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-29",24,24,1497,,0.004,0.001,711.9,0.059,0.036,0.006,11978.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-09-30",24,24,1516,,0.004,0.001,711,0.0592,0.036,0.006,11961.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-01",24,24,1512,,0.004,0.001,703.1,0.0592,0.035,0.006,11832.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-02",24,24,1512,,0.004,0.001,708.2,0.0593,0.036,0.006,11914.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-03",24,24,1506,,0.004,0.001,704.5,0.0591,0.036,0.006,11856.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-04",24,24,1479,,0.004,0.001,702.4,0.059,0.035,0.006,11818,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-05",24,24,1495,,0.004,0.001,708.5,0.0591,0.036,0.006,11924,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-06",24,24,1480,,0.004,0.001,695.6,0.0593,0.035,0.006,11703.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-07",24,24,1386,,0.003,0.001,666.1,0.0591,0.034,0.006,11210.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-08",24,24,1479,,0.003,0.001,682,0.0591,0.034,0.006,11477.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-09",24,24,1489,,0.004,0.001,704.9,0.0592,0.036,0.006,11859.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-10",24,24,1376,,0.003,0.001,649.8,0.0593,0.033,0.006,10932.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-11",24,24,1373,,0.003,0.001,651.2,0.0591,0.033,0.006,10957,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-12",24,24,1490,,0.004,0.001,707.8,0.0591,0.036,0.006,11914.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-13",24,24,1492,,0.004,0.001,705.3,0.0591,0.036,0.006,11872.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-14",20,19.15,1157.75,,0.003,0.001,542.405,0.0593,0.029,0.0069,9125.275,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-15",24,24,1505,,0.003,0.001,678.4,0.0591,0.034,0.006,11414.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-16",24,24,1478,,0.003,0.001,674.1,0.0592,0.034,0.006,11344.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-17",24,24,1491,,0.003,0.001,688,0.0591,0.035,0.006,11578.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-18",24,24,1508,,0.003,0.001,690.5,0.0591,0.035,0.006,11619.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-19",24,24,1495,,0.004,0.001,699.3,0.0593,0.035,0.006,11762.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-20",24,24,1470,,0.003,0.001,688.5,0.0591,0.035,0.006,11585.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-21",24,24,1485,,0.003,0.001,688.3,0.0591,0.035,0.006,11582.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-22",24,24,1460,,0.003,0.001,672.9,0.0591,0.034,0.006,11327.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-23",24,24,1411,,0.003,0.001,647.5,0.0594,0.033,0.006,10890.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-24",23,22.05,1244,,0.003,0.001,579.07,0.0591,0.029,0.0064,9746.445,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-25",11,10.47,514.41,,0.001,0.001,260.196,0.0595,0.02,0.0175,4376.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-26",24,24,1482,,0.003,0.001,688.1,0.0591,0.035,0.006,11582,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-27",24,24,1478,,0.003,0.001,675.6,0.059,0.034,0.006,11370.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-28",24,24,1483,,0.003,0.001,674.3,0.0593,0.034,0.006,11342.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-29",24,24,1473,,0.003,0.001,666.9,0.0592,0.034,0.006,11220.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-30",24,24,1491,,0.003,0.001,679.3,0.0592,0.034,0.006,11432,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-10-31",24,23.07,1390,,0.003,0.001,638.185,0.0592,0.032,0.006,10741.375,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-18",7,5.47,140.3,,0,0.001,91.542,0.0593,0.01,0.022,1539.828,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-19",13,12.05,647.59,,0.002,0.001,325.503,0.0592,0.021,0.0175,5476.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-20",9,7.71,337.72,,0.001,0.001,185.629,0.0591,0.016,0.0239,3123.521,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-21",18,17.08,1056.24,,0.002,0.001,492.872,0.0591,0.032,0.0147,8295.308,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-22",24,24,1512,,0.004,0.001,693.7,0.0591,0.035,0.006,11678,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-23",24,24,1446,,0.003,0.001,655.4,0.0592,0.033,0.006,11028.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-24",24,24,1501,,0.003,0.001,684.5,0.0593,0.035,0.006,11516.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-25",24,24,1438,,0.003,0.001,656.9,0.0592,0.033,0.006,11052.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-26",24,24,1535,,0.004,0.001,699.7,0.0591,0.035,0.006,11772.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-27",24,24,1521,,0.004,0.001,698.5,0.0591,0.035,0.006,11751.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-28",24,24,1459,,0.003,0.001,676.4,0.0592,0.034,0.006,11377.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-29",24,24,1460,,0.003,0.001,677.6,0.0592,0.034,0.006,11400.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-11-30",24,24,1498,,0.004,0.001,696.7,0.0592,0.035,0.006,11723,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-01",24,24,1517,,0.004,0.001,705.8,0.0592,0.036,0.006,11873.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-02",24,24,1523,,0.004,0.001,711.7,0.0592,0.036,0.006,11975.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-03",24,24,1544,,0.004,0.001,712.2,0.0591,0.036,0.006,11983.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-04",24,24,1516,,0.004,0.001,694.8,0.059,0.035,0.006,11696.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-05",24,24,1531,,0.004,0.001,702.5,0.0592,0.035,0.006,11823.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-06",24,24,1527,,0.004,0.001,700.7,0.059,0.035,0.006,11794.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-07",24,24,1496,,0.003,0.001,689.4,0.0592,0.035,0.006,11599.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-08",24,24,1526,,0.004,0.001,698.3,0.059,0.035,0.006,11750.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-09",24,24,1518,,0.004,0.001,699.7,0.0592,0.032,0.0054,11771.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-10",24,24,1492,,0.003,0.001,682.6,0.0592,0.034,0.006,11486.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-11",24,24,1545,,0.004,0.001,707.5,0.0592,0.036,0.006,11906.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-12",24,24,1531,,0.004,0.001,701.7,0.0593,0.035,0.006,11806.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-13",24,24,1537,,0.004,0.001,704.4,0.059,0.036,0.006,11854.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-14",24,24,1476,,0.003,0.001,676.3,0.0592,0.034,0.006,11380.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-15",24,24,1494,,0.003,0.001,687.3,0.0592,0.035,0.006,11567.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-16",24,24,1495,,0.003,0.001,685.7,0.0591,0.035,0.006,11537.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-17",24,24,1497,,0.003,0.001,683.6,0.059,0.035,0.006,11503.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-18",24,24,1515,,0.004,0.001,693.8,0.0592,0.035,0.006,11675.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-19",24,24,1524,,0.004,0.001,697.7,0.0592,0.035,0.006,11743.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-20",24,24,1477,,0.003,0.001,679.8,0.0591,0.034,0.006,11441.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-21",24,24,1466,,0.003,0.001,673,0.0591,0.034,0.006,11326.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-22",24,24,1478,,0.003,0.001,678.9,0.0593,0.034,0.006,11422.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-23",24,24,1519,,0.004,0.001,701.5,0.0591,0.035,0.006,11803.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-24",24,24,1482,,0.003,0.001,686.5,0.0591,0.035,0.006,11548.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-25",24,24,1487,,0.003,0.001,685.4,0.0593,0.035,0.006,11529.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-26",22,20.58,1164.71,,0.003,0.001,552.992,0.0591,0.03,0.0086,9305.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-27",24,24,1511,,0.003,0.001,692,0.0591,0.035,0.006,11644.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-28",24,24,1502,,0.003,0.001,689.1,0.0592,0.035,0.006,11595.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-29",24,24,1515,,0.003,0.001,691.2,0.0592,0.035,0.006,11629.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-30",24,24,1509,,0.003,0.001,688.3,0.0591,0.035,0.006,11583.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Donald Von Raesfeld",56026,"PCT2",,"2020-12-31",24,24,1503,,0.003,0.001,686.9,0.0592,0.035,0.006,11557.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-01",24,24,840,,0.002,0.001,411.7,0.0594,0.024,0.007,6924.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-02",24,24,849,,0.002,0.001,417.2,0.0594,0.024,0.0069,7018.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-03",24,24,856,,0.002,0.001,417.7,0.0592,0.024,0.007,7027.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-04",24,24,840,,0.002,0.001,414.4,0.0595,0.024,0.0069,6968.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-05",24,24,850,,0.002,0.001,416.7,0.0594,0.024,0.0069,7008.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-06",24,24,1055,,0.002,0.001,490.6,0.0593,0.028,0.0068,8256,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-07",24,24,1136,,0.003,0.001,523,0.0593,0.03,0.0068,8797.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-08",24,24,1047,,0.002,0.001,486.8,0.0591,0.028,0.0068,8190.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-09",24,24,1000,,0.002,0.001,471.6,0.0595,0.027,0.0069,7933.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-10",24,24,910,,0.002,0.001,438.5,0.0592,0.025,0.0068,7380.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-11",24,24,845,,0.002,0.001,415.3,0.0595,0.024,0.0069,6986.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-12",24,24,840,,0.002,0.001,412.4,0.0592,0.024,0.0069,6936.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-13",24,24,867,,0.002,0.001,422.3,0.0594,0.024,0.0069,7101.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-14",24,24,862,,0.002,0.001,420.4,0.0593,0.025,0.007,7074.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-15",24,24,889,,0.002,0.001,431.1,0.0594,0.025,0.0069,7253.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-16",24,24,868,,0.002,0.001,422.4,0.0592,0.025,0.0069,7111.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-17",24,24,865,,0.002,0.001,421.9,0.0594,0.025,0.007,7094.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-18",24,24,846,,0.002,0.001,414.6,0.0591,0.024,0.0069,6979.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-19",24,24,859,,0.002,0.001,418.3,0.0595,0.024,0.007,7036.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-20",24,24,889,,0.002,0.001,430.2,0.0592,0.025,0.007,7239.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-21",24,24,840,,0.002,0.001,411.6,0.0591,0.024,0.007,6930.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-22",24,24,840,,0.002,0.001,412,0.0593,0.024,0.0069,6937.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-23",24,24,844,,0.002,0.001,412.7,0.0591,0.024,0.0068,6941.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-24",24,23.33,817.92,,0.002,0.001,400.551,0.0592,0.023,0.0073,6744.041,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-25",9,8.83,313.64,,0.001,0.001,164.132,0.0593,0.027,0.0276,2762.169,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-26",24,24,840,,0.002,0.001,412.1,0.0593,0.024,0.0069,6933.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-27",24,24,842,,0.002,0.001,413.5,0.0592,0.024,0.0069,6962.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-28",24,24,854,,0.002,0.001,417.9,0.0595,0.024,0.0068,7028.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-29",24,24,857,,0.002,0.001,418.4,0.0595,0.024,0.007,7035.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-30",24,24,846,,0.002,0.001,414.1,0.0595,0.024,0.0069,6963.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-01-31",24,24,845,,0.002,0.001,413.7,0.0591,0.024,0.0069,6966.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-01",24,24,1245,,0.003,0.001,572.8,0.0592,0.033,0.0068,9637.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-02",24,24,860,,0.002,0.001,421.2,0.0591,0.025,0.007,7089.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-03",24,24,908,,0.002,0.001,437.8,0.0592,0.026,0.0069,7370.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-04",24,24,1032,,0.002,0.001,484.2,0.0592,0.028,0.0069,8149.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-05",24,24,972,,0.002,0.001,462.3,0.0592,0.027,0.0069,7779.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-06",24,22.31,785.67,,0.002,0.001,388.847,0.0592,0.031,0.0098,6546.229,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-07",24,24,858,,0.002,0.001,421.1,0.0591,0.025,0.007,7089.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-08",9,7.28,250.16,,0.001,0.001,125.994,0.0594,0.023,0.032,2118.318,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-09",24,24,850,,0.002,0.001,417.9,0.0593,0.025,0.007,7031.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-10",24,24,853,,0.002,0.001,418.7,0.0592,0.025,0.007,7048.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-11",24,24,857,,0.002,0.001,420.3,0.0593,0.025,0.007,7073.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-12",24,24,846,,0.002,0.001,417.4,0.0593,0.024,0.007,7023.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-13",24,24,864,,0.002,0.001,423.4,0.0595,0.025,0.007,7121.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-14",24,24,878,,0.002,0.001,429.1,0.0593,0.025,0.007,7224.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-15",24,24,843,,0.002,0.001,417.7,0.059,0.025,0.007,7029.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-16",8,6.48,293,,0.001,0.001,147.356,0.0594,0.028,0.0354,2480.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-17",9,8.2,344.4,,0.001,0.001,173.06,0.0594,0.027,0.0418,2910.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-18",19,17.25,603.52,,0.002,0.0009,318.837,0.0615,0.032,0.0133,5366.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-19",24,24,872,,0.002,0.001,423.6,0.0593,0.025,0.0069,7129.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-20",24,24,844,,0.002,0.001,415.5,0.0595,0.024,0.007,6988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-21",24,24,853,,0.002,0.001,416.3,0.0593,0.024,0.007,7001.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-22",24,24,841,,0.002,0.001,415.2,0.0596,0.025,0.0071,6977.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-23",1,0.03,0.03,,0,0.001,0.21,0.059,0,0.113,3.546,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-24",18,17.87,652.31,,0.002,0.001,318.709,0.0591,0.035,0.0174,5366.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-25",24,24,864,,0.002,0.001,421.6,0.0592,0.025,0.007,7096.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-26",24,24,856,,0.002,0.001,418.7,0.0591,0.025,0.007,7051.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-27",24,24,862,,0.002,0.001,421.5,0.0591,0.025,0.007,7096.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-28",24,24,870,,0.002,0.001,423.4,0.0593,0.025,0.0069,7124.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-02-29",24,24,844,,0.002,0.001,416.1,0.0592,0.025,0.007,7002.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-01",10,8.7,304.6,,0.001,0.001,151.84,0.0593,0.024,0.0268,2555.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-02",24,24,883,,0.002,0.001,430.4,0.0593,0.025,0.007,7242.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-03",24,24,902,,0.002,0.001,436.8,0.0593,0.027,0.0073,7347.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-04",24,24,844,,0.002,0.001,415.3,0.0593,0.028,0.008,6991.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-05",24,24,842,,0.002,0.001,414.5,0.0595,0.027,0.0079,6970.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-06",24,24,844,,0.002,0.001,415.6,0.0593,0.028,0.008,6994.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-07",20,19.55,704.1,,0.002,0.001,345.585,0.0593,0.036,0.017,5816.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-08",24,24,858,,0.002,0.001,420.2,0.0593,0.028,0.008,7069.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-09",24,24,893,,0.002,0.001,432.8,0.0593,0.029,0.0079,7282.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-10",24,24,957,,0.002,0.001,455.7,0.0594,0.03,0.008,7666.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-11",24,24,876,,0.002,0.001,425.9,0.0593,0.028,0.008,7169.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-12",24,24,1013,,0.002,0.001,475.1,0.0592,0.031,0.0079,8001.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-13",24,24,988,,0.002,0.001,467.8,0.0594,0.031,0.0078,7867.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-14",24,24,924,,0.002,0.001,443.7,0.0595,0.029,0.0078,7462.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-15",24,24,951,,0.002,0.001,453.7,0.0594,0.03,0.0079,7631.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-16",24,24,956,,0.002,0.001,453.9,0.0593,0.03,0.008,7634.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-17",24,24,842,,0.002,0.001,414.3,0.0594,0.028,0.008,6967.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-18",24,24,843,,0.002,0.001,414.9,0.0592,0.028,0.008,6979.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-19",24,24,852,,0.002,0.001,418.2,0.0593,0.028,0.008,7038.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-20",24,24,842,,0.002,0.001,414.3,0.0594,0.028,0.008,6968.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-21",24,24,850,,0.002,0.001,416.7,0.0591,0.028,0.008,7017.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-22",24,24,850,,0.002,0.001,417.1,0.0595,0.028,0.0079,7016.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-23",24,24,843,,0.002,0.001,413.3,0.0593,0.027,0.0078,6954.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-24",24,24,843,,0.002,0.001,414.6,0.0591,0.028,0.008,6982.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-25",24,24,842,,0.002,0.001,413.4,0.0593,0.028,0.008,6951.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-26",24,23.85,835.65,,0.002,0.001,411.7,0.0592,0.029,0.0085,6930.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-27",21,20.83,743.13,,0.002,0.001,374.16,0.0595,0.038,0.0156,6291.411,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-28",13,12.23,406.6,,0.001,0.001,206.643,0.0591,0.029,0.0208,3476.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-29",24,24,871,,0.002,0.001,427.7,0.0594,0.029,0.008,7196.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-30",24,24,846,,0.002,0.001,419.3,0.0592,0.028,0.008,7059.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-03-31",24,24,852,,0.002,0.001,421.4,0.0594,0.028,0.008,7085.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-01",24,24,844,,0.002,0.001,415.8,0.0592,0.028,0.008,7001.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-02",24,24,840,,0.002,0.001,416.3,0.0592,0.028,0.008,7009.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-03",24,24,846,,0.002,0.001,416.9,0.0594,0.028,0.008,7009.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-04",15,13.95,522.13,,0.001,0.001,254.943,0.0591,0.035,0.0241,4289.783,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-05",24,24,976,,0.002,0.001,468.2,0.0592,0.031,0.0079,7876.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-06",24,24,867,,0.002,0.001,422.9,0.0595,0.028,0.0079,7114.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-07",24,24,847,,0.002,0.001,418.1,0.0593,0.028,0.008,7032.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-08",24,24,870,,0.002,0.001,427.9,0.0592,0.028,0.0079,7200.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-09",24,24,911,,0.002,0.001,441.8,0.0592,0.029,0.0078,7435.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-10",24,24,848,,0.002,0.001,419.4,0.0593,0.028,0.008,7056.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-11",24,24,840,,0.002,0.001,415.6,0.0593,0.027,0.0078,6996.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-12",24,24,857,,0.002,0.001,423.1,0.0593,0.028,0.0079,7120.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-13",24,24,840,,0.002,0.001,418.2,0.0593,0.028,0.008,7034.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-14",24,24,873,,0.002,0.001,433.3,0.0593,0.029,0.008,7292.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-15",24,24,840,,0.002,0.001,418.5,0.0593,0.028,0.008,7040.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-16",24,24,842,,0.002,0.001,419.8,0.0593,0.028,0.008,7062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-17",24,24,846,,0.002,0.001,417.4,0.0591,0.028,0.008,7028.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-18",24,24,847,,0.002,0.001,419.6,0.0595,0.028,0.008,7055.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-19",24,24,842,,0.002,0.001,417.2,0.0593,0.028,0.008,7019.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-20",24,24,858,,0.002,0.001,422.9,0.0596,0.028,0.008,7112.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-21",24,24,859,,0.002,0.001,423.4,0.0594,0.028,0.008,7121.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-22",24,24,849,,0.002,0.001,419.8,0.0594,0.028,0.008,7062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-23",24,24,847,,0.002,0.001,417.6,0.0594,0.028,0.008,7024.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-24",24,24,873,,0.002,0.001,425.3,0.0592,0.028,0.0079,7159.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-25",24,24,846,,0.002,0.001,417.4,0.0593,0.028,0.008,7024.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-26",24,24,857,,0.002,0.001,422.6,0.0593,0.028,0.008,7110.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-27",24,24,850,,0.002,0.001,421.4,0.0593,0.028,0.008,7088.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-28",24,24,860,,0.002,0.001,424.3,0.0592,0.028,0.0079,7142.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-29",24,24,844,,0.002,0.001,416.6,0.0591,0.028,0.008,7016.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-04-30",24,24,843,,0.002,0.001,418,0.0595,0.028,0.0079,7033.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-01",24,23.37,846.03,,0.002,0.001,413.232,0.0595,0.029,0.0092,6951.645,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-04",19,18.23,746.61,,0.002,0.001,355.417,0.0591,0.047,0.0279,5981.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-05",24,24,899,,0.002,0.001,435.6,0.0593,0.029,0.0079,7330.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-06",24,23.42,876.86,,0.002,0.001,422.656,0.0593,0.028,0.008,7112.192,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-07",21,20.33,747.31,,0.002,0.001,362.94,0.0594,0.035,0.0161,6104.249,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-08",24,24,901,,0.002,0.001,434.4,0.0593,0.029,0.0079,7305.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-09",24,24,928,,0.002,0.001,446,0.0595,0.03,0.008,7501.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-10",24,24,849,,0.002,0.001,413.5,0.0591,0.028,0.008,6963.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-11",24,24,889,,0.002,0.001,430,0.0593,0.029,0.008,7235.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-12",24,24,873,,0.002,0.001,425.6,0.0596,0.029,0.008,7154.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-13",24,24,872,,0.002,0.001,426.5,0.0592,0.029,0.008,7177.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-14",24,24,875,,0.002,0.001,427.9,0.0592,0.029,0.008,7201,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-15",24,24,851,,0.002,0.001,418.8,0.0593,0.028,0.008,7044.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-16",24,24,923,,0.002,0.001,444.2,0.0592,0.03,0.008,7476.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-17",24,24,884,,0.002,0.001,429.9,0.0594,0.029,0.008,7231.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-18",24,24,865,,0.002,0.001,424,0.0591,0.028,0.0079,7136.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-19",24,24,840,,0.002,0.001,415.5,0.0593,0.028,0.008,6991.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-20",24,24,842,,0.002,0.001,416.4,0.0594,0.028,0.008,7005.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-21",24,24,940,,0.002,0.001,452.7,0.0594,0.03,0.0079,7615.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-22",24,24,884,,0.002,0.001,434.3,0.0592,0.029,0.008,7309.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-23",21,20.75,745.11,,0.002,0.001,376,0.0593,0.035,0.0127,6325.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-24",24,24,858,,0.002,0.001,422.6,0.0595,0.028,0.0079,7108.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-25",24,24,943,,0.002,0.001,454.3,0.0594,0.03,0.0079,7644,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-26",24,24,960,,0.002,0.001,458.1,0.0593,0.031,0.008,7707.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-27",24,24,929,,0.002,0.001,447,0.0593,0.03,0.008,7518.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-28",24,24,888,,0.002,0.001,432.5,0.0592,0.029,0.008,7279.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-29",24,24,944,,0.002,0.001,453.7,0.0593,0.03,0.0079,7633.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-30",24,24,896,,0.002,0.001,435.9,0.0592,0.029,0.0079,7336.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-05-31",24,24,876,,0.002,0.001,430,0.0593,0.029,0.008,7234.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-01",24,24,878,,0.002,0.001,425.7,0.0594,0.029,0.008,7159.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-02",24,24,928,,0.002,0.001,442.6,0.0593,0.03,0.008,7447.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-03",24,24,946,,0.002,0.001,448.7,0.0592,0.03,0.008,7552.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-04",24,24,848,,0.002,0.001,415.4,0.0593,0.028,0.008,6989.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-05",24,24,845,,0.002,0.001,414.8,0.0594,0.028,0.008,6975.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-06",24,24,843,,0.002,0.001,414.3,0.0592,0.028,0.008,6968.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-07",24,24,845,,0.002,0.001,414.7,0.0593,0.028,0.008,6979.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-08",24,24,924,,0.002,0.001,442.3,0.0593,0.03,0.008,7440.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-09",24,24,928,,0.002,0.001,442.5,0.0591,0.029,0.0079,7447,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-10",24,24,974,,0.002,0.001,460.7,0.0593,0.031,0.008,7750.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-11",24,24,926,,0.002,0.001,443.2,0.0595,0.03,0.008,7451.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-12",24,24,862,,0.002,0.001,419.8,0.0593,0.028,0.008,7064,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-13",24,24,855,,0.002,0.001,417,0.0593,0.028,0.0079,7018.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-14",24,24,873,,0.002,0.001,423.5,0.0594,0.028,0.0079,7121.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-15",24,24,897,,0.002,0.001,431.9,0.0594,0.029,0.0079,7263.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-16",24,24,903,,0.002,0.001,433.8,0.0594,0.029,0.008,7299.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-17",24,24,847,,0.002,0.001,414,0.0595,0.028,0.008,6961.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-18",24,24,852,,0.002,0.001,416.6,0.0592,0.028,0.008,7009.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-19",24,24,875,,0.002,0.001,424.6,0.0595,0.028,0.008,7140.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-20",24,24,874,,0.002,0.001,423.6,0.0594,0.028,0.008,7124.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-21",24,24,880,,0.002,0.001,425.9,0.0595,0.029,0.008,7161.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-22",24,24,931,,0.002,0.001,444.2,0.0597,0.03,0.008,7464.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-23",24,24,893,,0.002,0.001,431.2,0.0592,0.029,0.008,7254.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-24",24,24,952,,0.002,0.001,453,0.0593,0.03,0.0078,7619.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-25",24,24,896,,0.002,0.001,433.8,0.0594,0.029,0.008,7296.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-26",24,24,943,,0.002,0.001,447.5,0.0593,0.03,0.008,7527.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-27",24,24,965,,0.002,0.001,456.7,0.0593,0.03,0.0079,7682.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-28",24,24,870,,0.002,0.001,421.8,0.0592,0.028,0.008,7101,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-29",24,24,856,,0.002,0.001,418.7,0.0592,0.028,0.008,7043.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-06-30",24,24,895,,0.002,0.001,432.3,0.0591,0.029,0.008,7279.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-01",24,24,864,,0.002,0.001,419.5,0.0592,0.028,0.008,7064.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-02",24,24,871,,0.002,0.001,422.2,0.0594,0.028,0.008,7102.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-03",20,19.35,659.88,,0.002,0.001,329.241,0.0595,0.034,0.0148,5534.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-04",24,24,870,,0.002,0.001,422.4,0.0593,0.028,0.0079,7107.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-05",24,24,879,,0.002,0.001,424.7,0.0593,0.029,0.008,7143.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-06",24,24,929,,0.002,0.001,442,0.0591,0.029,0.0079,7445.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-07",24,24,956,,0.002,0.001,452.2,0.0593,0.03,0.008,7607.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-08",24,24,879,,0.002,0.001,425.8,0.0595,0.028,0.008,7158.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-09",24,24,952,,0.002,0.001,452.4,0.0593,0.03,0.008,7613.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-10",24,24,1035,,0.002,0.001,483.3,0.0593,0.033,0.008,8127.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-11",24,24,1035,,0.002,0.001,482.5,0.0595,0.032,0.0079,8115.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-12",24,24,1029,,0.002,0.001,479.4,0.059,0.032,0.008,8075.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-13",24,24,989,,0.002,0.001,464.1,0.0591,0.031,0.008,7812.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-14",24,24,899,,0.002,0.001,431.3,0.0592,0.029,0.008,7259.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-15",24,24,887,,0.002,0.001,428.1,0.0593,0.028,0.0079,7204.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-16",24,24,896,,0.002,0.001,430.2,0.0594,0.029,0.008,7235.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-17",24,24,894,,0.002,0.001,430.3,0.0592,0.029,0.008,7241.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-18",24,24,866,,0.002,0.001,418.9,0.0591,0.028,0.008,7053.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-19",24,24,840,,0.002,0.001,410.6,0.059,0.028,0.008,6913.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-20",24,24,857,,0.002,0.001,417.3,0.0594,0.028,0.008,7020.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-21",24,24,871,,0.002,0.001,421.6,0.0592,0.028,0.008,7098.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-22",24,24,858,,0.002,0.001,416.9,0.0591,0.028,0.0079,7023.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-23",24,24,852,,0.002,0.001,416.1,0.0594,0.028,0.0079,7002.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-24",24,24,864,,0.002,0.001,420.5,0.0594,0.028,0.008,7070.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-25",24,24,898,,0.002,0.001,433.5,0.0593,0.029,0.0079,7294.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-26",24,24,1238,,0.003,0.001,562.7,0.0592,0.038,0.008,9469.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-27",24,24,905,,0.002,0.001,435.3,0.0594,0.029,0.008,7322.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-28",24,24,880,,0.002,0.001,426.8,0.0592,0.029,0.008,7186.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-29",24,24,927,,0.002,0.001,443,0.0594,0.03,0.008,7448.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-30",24,24,1013,,0.002,0.001,476.2,0.0593,0.031,0.0079,8007.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-07-31",24,24,1063,,0.002,0.001,494.6,0.0593,0.033,0.0079,8324.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-01",24,23.17,845.23,,0.002,0.001,408.755,0.0592,0.028,0.0097,6879.695,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-02",8,7.75,255.75,,0.001,0.001,128.3,0.0594,0.024,0.0326,2157.575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-03",24,24,868,,0.002,0.001,421.7,0.0593,0.028,0.008,7094.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-04",24,24,840,,0.002,0.001,411.9,0.0594,0.028,0.008,6925.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-05",24,24,845,,0.002,0.001,413.4,0.0593,0.028,0.008,6956.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-06",24,24,840,,0.002,0.001,412.4,0.0594,0.028,0.008,6936.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-07",24,24,869,,0.002,0.001,423.1,0.0593,0.028,0.008,7115.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-08",24,24,850,,0.002,0.001,418.3,0.0592,0.028,0.008,7038.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-09",24,24,870,,0.002,0.001,423.8,0.0594,0.028,0.008,7128.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-10",24,24,888,,0.002,0.001,429.7,0.0592,0.029,0.008,7230.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-11",24,24,872,,0.002,0.001,424.3,0.0594,0.029,0.008,7132.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-12",24,24,970,,0.002,0.001,459.6,0.0594,0.031,0.008,7732.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-13",24,24,1127,,0.003,0.001,516.2,0.0591,0.035,0.008,8686.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-14",24,24,1153,,0.003,0.001,524.5,0.0592,0.035,0.008,8827,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-15",24,24,1184,,0.003,0.001,536.7,0.0591,0.035,0.0077,9032.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-16",24,24,986,,0.002,0.001,463.2,0.0593,0.031,0.0079,7793.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-17",24,24,1257,,0.003,0.001,562.6,0.0592,0.037,0.0079,9465.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-18",24,24,990,,0.002,0.001,466.2,0.0593,0.031,0.008,7842.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-19",24,24,1127,,0.003,0.001,520.6,0.0592,0.035,0.0079,8762.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-20",24,24,1057,,0.002,0.001,493.3,0.0591,0.032,0.0077,8301.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-21",24,24,1066,,0.003,0.001,502.5,0.0593,0.033,0.0078,8452.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-22",24,24,990,,0.002,0.001,470.9,0.0593,0.031,0.0078,7926,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-23",24,24,1060,,0.002,0.001,488.9,0.0593,0.032,0.0078,8225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-24",24,24,1086,,0.003,0.001,503.8,0.0593,0.033,0.0077,8478.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-25",24,24,1002,,0.002,0.001,468.9,0.0593,0.029,0.0075,7889.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-26",24,24,991,,0.002,0.001,465.4,0.0591,0.027,0.007,7836.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-27",24,24,1080,,0.003,0.001,499.8,0.0592,0.029,0.007,8412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-28",24,24,984,,0.002,0.001,464.4,0.0591,0.027,0.007,7818.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-29",23,21.55,751.17,,0.002,0.001,368.822,0.0595,0.025,0.013,6203.913,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-30",24,24,972,,0.002,0.001,483.1,0.0593,0.039,0.0097,8128,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-08-31",24,24,840,,0.002,0.001,410.4,0.0591,0.024,0.007,6911.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-01",24,24,853,,0.002,0.001,418.3,0.0593,0.025,0.007,7037.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-02",24,24,834,,0.002,0.001,417.6,0.0594,0.025,0.007,7023.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-03",24,24,974,,0.002,0.001,460.1,0.0593,0.027,0.007,7742.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-04",24,24,1061,,0.003,0.001,497.3,0.0595,0.029,0.007,8362.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-05",24,24,1156,,0.003,0.001,534.3,0.0593,0.031,0.007,8988.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-06",24,24,1111,,0.003,0.001,509,0.0593,0.03,0.007,8562.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-07",24,24,885,,0.002,0.001,428.6,0.0595,0.025,0.007,7207.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-08",24,24,856,,0.002,0.001,418.2,0.0592,0.025,0.007,7036.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-09",24,24,850,,0.002,0.001,415.1,0.0593,0.024,0.007,6983.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-10",24,24,871,,0.002,0.001,425.6,0.0595,0.025,0.007,7156.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-11",24,24,875,,0.002,0.001,425.7,0.0592,0.025,0.007,7167.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-12",24,24,886,,0.002,0.001,429.5,0.0593,0.025,0.007,7224.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-13",24,24,855,,0.002,0.001,417,0.0593,0.025,0.007,7013.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-14",24,24,897,,0.002,0.001,434.2,0.0592,0.026,0.007,7305.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-15",24,24,915,,0.002,0.001,439.5,0.0593,0.028,0.0076,7392.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-16",24,24,945,,0.002,0.001,448.5,0.0592,0.03,0.008,7551.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-17",24,24,970,,0.002,0.001,460.2,0.059,0.031,0.0079,7747.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-18",24,24,1045,,0.002,0.001,491,0.0593,0.033,0.0079,8260.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-19",24,24,938,,0.002,0.001,446.1,0.0592,0.03,0.008,7508.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-20",24,24,956,,0.002,0.001,456.3,0.0594,0.03,0.008,7677.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-21",24,23.35,890.35,,0.002,0.001,434.475,0.0593,0.042,0.012,7310.965,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-22",24,24,878,,0.002,0.001,426,0.0593,0.029,0.008,7166.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-23",24,24,861,,0.002,0.001,420.3,0.0593,0.028,0.008,7073.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-24",24,24,840,,0.002,0.001,411.1,0.0594,0.028,0.008,6915,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-25",24,24,846,,0.002,0.001,413.1,0.0592,0.028,0.008,6954.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-26",24,24,840,,0.002,0.001,411.7,0.0595,0.028,0.008,6919.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-27",24,24,862,,0.002,0.001,419.2,0.0594,0.028,0.008,7049.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-28",24,24,961,,0.002,0.001,455.3,0.0591,0.03,0.008,7663.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-29",24,24,937,,0.002,0.001,446.9,0.0592,0.03,0.008,7523.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-09-30",24,24,905,,0.002,0.001,434.1,0.0593,0.029,0.0079,7301.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-01",24,24,914,,0.002,0.001,436.1,0.0593,0.029,0.0078,7338.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-02",24,24,938,,0.002,0.001,443.9,0.0593,0.03,0.008,7468.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-03",24,24,966,,0.002,0.001,454.7,0.0592,0.031,0.008,7654.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-04",17,16.75,679.25,,0.002,0.001,321.985,0.0592,0.028,0.0126,5417.475,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-05",24,24,1094,,0.003,0.001,504.1,0.0593,0.034,0.008,8477.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-06",24,24,1007,,0.002,0.001,470.8,0.0591,0.031,0.0079,7930.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-07",24,24,974,,0.002,0.001,459.9,0.0592,0.031,0.0079,7739.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-08",24,24,864,,0.002,0.001,424.3,0.0594,0.028,0.008,7138.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-09",24,24,882,,0.002,0.001,428.1,0.0593,0.029,0.008,7205.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-10",24,24,887,,0.002,0.001,429.8,0.0592,0.029,0.008,7233.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-11",24,24,847,,0.002,0.001,416.1,0.0591,0.028,0.008,7005.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-12",24,24,1043,,0.002,0.001,490.5,0.0592,0.032,0.0079,8255.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-13",24,24,915,,0.002,0.001,439.1,0.0593,0.03,0.008,7387,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-14",24,24,991,,0.002,0.001,470.4,0.0594,0.031,0.0079,7913.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-15",24,24,982,,0.002,0.001,463,0.0593,0.031,0.008,7790.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-16",24,24,856,,0.002,0.001,417.1,0.0595,0.028,0.008,7013.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-17",24,24,857,,0.002,0.001,418.7,0.0592,0.028,0.008,7047.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-18",24,24,886,,0.002,0.001,429,0.0592,0.029,0.008,7218.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-19",24,24,968,,0.002,0.001,458.1,0.0593,0.031,0.008,7708.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-20",24,24,934,,0.002,0.001,444,0.0594,0.03,0.008,7470.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-21",24,24,975,,0.002,0.001,461,0.0593,0.031,0.008,7757.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-22",24,24,1057,,0.002,0.001,491.5,0.0593,0.033,0.008,8270.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-23",24,24,962,,0.002,0.001,456.6,0.0593,0.031,0.008,7684.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-24",24,24,961,,0.002,0.001,455.2,0.0592,0.031,0.008,7661.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-25",24,24,994,,0.002,0.001,468.4,0.0593,0.032,0.008,7879.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-26",24,24,1106,,0.003,0.001,508.1,0.0593,0.034,0.008,8552.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-27",24,24,1033,,0.002,0.001,480.8,0.0592,0.032,0.008,8091.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-28",24,24,939,,0.002,0.001,449.1,0.0593,0.03,0.008,7555.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-29",24,24,957,,0.002,0.001,455.7,0.0591,0.031,0.008,7670.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-30",24,24,946,,0.002,0.001,451.4,0.0592,0.03,0.008,7596.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-10-31",24,23.15,813.1,,0.002,0.001,401.445,0.0595,0.028,0.0099,6749.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-09",10,9.18,395.36,,0.001,0.001,203.616,0.0593,0.039,0.0479,3424.674,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-10",24,24,947,,0.002,0.001,454,0.0594,0.03,0.0079,7637.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-11",24,24,851,,0.002,0.001,416.3,0.0591,0.028,0.008,7008.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-12",24,24,874,,0.002,0.001,425.4,0.0594,0.029,0.008,7157.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-13",24,24,847,,0.002,0.001,416.4,0.0593,0.028,0.008,7007,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-14",24,24,840,,0.002,0.001,416.7,0.0592,0.028,0.008,7015.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-15",24,24,845,,0.002,0.001,416.9,0.0592,0.028,0.008,7016.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-16",24,24,888,,0.002,0.001,433.7,0.0594,0.029,0.008,7295,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-17",24,24,842,,0.002,0.001,415.5,0.0592,0.028,0.008,6994.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-18",24,24,845,,0.002,0.001,416.4,0.0592,0.028,0.008,7009.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-19",24,24,851,,0.002,0.001,419.9,0.0593,0.028,0.008,7062.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-20",13,12.58,441.14,,0.001,0.001,219.26,0.0595,0.015,0.008,3685.564,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-22",19,18.53,630.3,,0.002,0.001,317.282,0.0594,0.037,0.02,5337.399,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-23",24,24,843,,0.002,0.001,416.5,0.0592,0.028,0.008,7008.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-24",24,24,844,,0.002,0.001,416.8,0.0593,0.028,0.008,7013.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-25",24,24,842,,0.002,0.001,414.1,0.0594,0.028,0.008,6966.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-26",24,24,846,,0.002,0.001,413.9,0.0592,0.028,0.008,6966.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-27",24,24,842,,0.002,0.001,414.3,0.0593,0.028,0.008,6973.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-28",24,24,859,,0.002,0.001,419.9,0.0594,0.028,0.008,7062.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-29",24,24,875,,0.002,0.001,424.4,0.0593,0.028,0.0079,7140.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-11-30",24,24,944,,0.002,0.001,449.2,0.0593,0.03,0.008,7559.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-01",24,24,948,,0.002,0.001,457.4,0.0592,0.031,0.0079,7701.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-02",24,24,850,,0.002,0.001,422.7,0.0593,0.028,0.008,7111.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-03",24,24,874,,0.002,0.001,431.3,0.0593,0.029,0.008,7257.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-04",24,24,866,,0.002,0.001,425.1,0.0593,0.029,0.008,7150.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-05",24,24,845,,0.002,0.001,416.6,0.0592,0.028,0.008,7013,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-06",24,24,848,,0.002,0.001,416.2,0.0591,0.028,0.008,7007.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-07",24,24,849,,0.002,0.001,417.3,0.0593,0.028,0.0079,7018.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-08",24,24,840,,0.002,0.001,414.4,0.0597,0.028,0.008,6965.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-09",24,24,842,,0.002,0.001,418.4,0.0594,0.028,0.008,7040.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-10",24,24,853,,0.002,0.001,421.9,0.0593,0.028,0.008,7099.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-11",24,24,892,,0.002,0.001,435.7,0.0592,0.029,0.008,7333.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-12",24,24,982,,0.002,0.001,469.3,0.0591,0.032,0.008,7898,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-13",24,24,842,,0.002,0.001,416.1,0.0593,0.028,0.008,7001.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-14",24,24,847,,0.002,0.001,417.3,0.0592,0.028,0.008,7020.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-15",24,24,860,,0.002,0.001,421.7,0.0594,0.028,0.008,7091.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-16",24,24,973,,0.002,0.001,462.1,0.0594,0.031,0.008,7774.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-17",24,24,840,,0.002,0.001,414.8,0.0591,0.028,0.008,6982.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-18",24,24,884,,0.002,0.001,433,0.0593,0.029,0.0079,7286.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-19",24,24,855,,0.002,0.001,423.5,0.0592,0.028,0.0079,7128.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-20",24,24,854,,0.002,0.001,418.5,0.0592,0.028,0.008,7041.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-21",24,24,840,,0.002,0.001,413.4,0.0593,0.028,0.008,6954.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-22",24,24,848,,0.002,0.001,419.3,0.0593,0.028,0.008,7058.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-23",24,24,842,,0.002,0.001,416.3,0.0594,0.028,0.008,7004.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-24",24,23.08,800.24,,0.002,0.001,397.224,0.0594,0.029,0.0151,6677.852,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-25",18,17.15,580.95,,0.001,0.001,292.65,0.0593,0.035,0.018,4925.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-27",5,4.42,132.94,,0,0.001,70.344,0.059,0.022,0.066,1185.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-28",24,24,1006,,0.002,0.001,476.7,0.0593,0.031,0.0078,8017.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-29",24,24,850,,0.002,0.001,421.5,0.0593,0.028,0.0078,7092.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-30",24,24,840,,0.002,0.001,416.6,0.0595,0.028,0.008,7007.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M1",,"2020-12-31",23,22.28,788.44,,0.002,0.001,388.916,0.0594,0.027,0.009,6539.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-01",24,24,864,,0.002,0.001,416.2,0.0595,0.027,0.0078,6998.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-02",24,24,871,,0.002,0.001,421.2,0.0591,0.028,0.008,7092.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-03",24,24,877,,0.002,0.001,422.6,0.0595,0.028,0.0078,7103.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-04",24,24,864,,0.002,0.001,418.3,0.0592,0.027,0.0078,7043.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-05",24,24,872,,0.002,0.001,420.5,0.0592,0.028,0.0078,7081.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-06",24,24,1073,,0.003,0.001,496.6,0.0594,0.033,0.0078,8350.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-07",24,23.37,1091.76,,0.003,0.001,503.814,0.0592,0.041,0.0115,8479.382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-08",24,24,1062,,0.002,0.001,493.9,0.0594,0.033,0.0079,8306,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-09",24,24,1016,,0.002,0.001,476,0.0593,0.032,0.0079,8009.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-10",24,24,928,,0.002,0.001,444.4,0.0593,0.029,0.0079,7473.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-11",24,24,869,,0.002,0.001,419.9,0.0591,0.028,0.0079,7070.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-12",24,24,864,,0.002,0.001,417,0.0596,0.027,0.0078,7009.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-13",24,24,888,,0.002,0.001,427.3,0.0596,0.028,0.0078,7183.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-14",24,24,880,,0.002,0.001,424.6,0.0594,0.028,0.0079,7141.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-15",24,24,912,,0.002,0.001,435.4,0.0592,0.028,0.0078,7330,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-16",24,24,889,,0.002,0.001,427.3,0.0593,0.028,0.0079,7187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-17",24,24,885,,0.002,0.001,426.2,0.0595,0.029,0.008,7168.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-18",24,24,868,,0.002,0.001,419.3,0.059,0.028,0.0078,7056.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-19",24,24,878,,0.002,0.001,422.8,0.0592,0.027,0.0077,7114.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-20",24,24,908,,0.002,0.001,435.1,0.0593,0.028,0.0078,7319.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-21",24,24,864,,0.002,0.001,416.3,0.0593,0.028,0.0079,7008.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-22",24,24,864,,0.002,0.001,416.7,0.0593,0.028,0.0079,7014.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-23",24,24,866,,0.002,0.001,417.6,0.0595,0.028,0.0079,7021.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-24",24,23.33,838.92,,0.002,0.001,405.85,0.0595,0.028,0.0086,6823.594,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-25",7,6.73,222.03,,0.001,0.001,111.646,0.0593,0.022,0.0356,1878.103,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-26",24,24,864,,0.002,0.001,416.2,0.0593,0.028,0.008,7005.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-27",24,24,865,,0.002,0.001,418,0.0591,0.028,0.0079,7037,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-28",24,24,876,,0.002,0.001,422,0.0594,0.028,0.008,7104,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-29",24,24,878,,0.002,0.001,422.6,0.0592,0.028,0.0078,7110.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-30",24,24,869,,0.002,0.001,419.3,0.0595,0.027,0.0077,7049.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-01-31",24,24,864,,0.002,0.001,419.4,0.0593,0.029,0.0081,7059.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-01",8,6.84,234.78,,0.001,0.0009,117.71,0.0591,0.026,0.0455,1981.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-02",24,24,884,,0.002,0.001,426.3,0.0591,0.029,0.008,7177.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-03",24,24,925,,0.002,0.001,442.4,0.0593,0.029,0.0078,7448.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-04",24,24,1056,,0.002,0.001,493.1,0.0592,0.032,0.0076,8301.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-05",24,24,993,,0.002,0.001,467.4,0.0593,0.031,0.0078,7865.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-06",24,24,917,,0.002,0.001,444.8,0.0593,0.029,0.0078,7481.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-07",24,24,882,,0.002,0.001,425.7,0.0594,0.028,0.0078,7160.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-08",24,24,1254,,0.003,0.001,578.4,0.0591,0.039,0.0079,9737.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-09",24,24,872,,0.002,0.001,422.7,0.0594,0.028,0.008,7109.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-10",24,24,875,,0.002,0.001,424.1,0.0593,0.028,0.0079,7135.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-11",24,24,877,,0.002,0.001,425.1,0.0593,0.028,0.008,7157.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-12",24,24,869,,0.002,0.001,422.2,0.0592,0.028,0.0079,7105.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-13",24,24,885,,0.002,0.001,428,0.0594,0.029,0.008,7201.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-14",24,24,900,,0.002,0.001,434.1,0.0593,0.028,0.0078,7303.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-15",24,24,868,,0.002,0.001,422.4,0.0593,0.028,0.0079,7108.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-16",1,0.23,4.83,,0,0.001,3.312,0.059,0.001,0.03,55.683,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-17",4,3.95,126.25,,0,0.001,65.125,0.0595,0.019,0.0473,1095.06,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-18",14,13.03,468.92,,0.001,0.001,229.904,0.0595,0.028,0.0209,3868.158,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-19",24,24,892,,0.002,0.001,429,0.0595,0.028,0.0078,7216.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-20",24,24,866,,0.002,0.001,420.3,0.0593,0.028,0.0079,7074.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-21",24,24,873,,0.002,0.001,421.4,0.0592,0.027,0.0076,7090.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-22",24,24,862,,0.002,0.001,420,0.0596,0.028,0.008,7058.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-23",1,0.03,0.03,,0,0.001,0.213,0.06,0,0.106,3.573,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-24",21,20.17,766.34,,0.002,0.001,381.054,0.0592,0.052,0.0269,6411.68,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-25",24,24,887,,0.002,0.001,426.8,0.0592,0.028,0.0078,7183.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-26",24,24,876,,0.002,0.001,423.9,0.0591,0.027,0.0077,7137.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-27",24,24,885,,0.002,0.001,426.8,0.0592,0.028,0.0078,7183.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-28",24,24,888,,0.002,0.001,429.1,0.0595,0.029,0.008,7214.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-02-29",24,24,867,,0.002,0.001,421.1,0.0593,0.028,0.008,7083.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-01",12,10.65,399,,0.001,0.001,202.7,0.0592,0.032,0.0236,3412.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-02",24,24,906,,0.002,0.001,435.3,0.0592,0.028,0.0077,7326.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-03",24,24,924,,0.002,0.001,442.8,0.0591,0.029,0.0078,7457.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-04",24,24,867,,0.002,0.001,420.4,0.0593,0.026,0.0072,7078.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-05",24,24,865,,0.002,0.001,419.1,0.0593,0.025,0.007,7055.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-06",24,24,868,,0.002,0.001,420.4,0.0593,0.024,0.0069,7071.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-07",22,21.22,796.12,,0.002,0.001,391.584,0.0593,0.038,0.0159,6589.808,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-08",24,24,878,,0.002,0.001,423.9,0.0594,0.025,0.0069,7135,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-09",24,24,910,,0.002,0.001,437.4,0.0593,0.025,0.0069,7359.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-10",24,24,976,,0.002,0.001,459.9,0.0592,0.026,0.0068,7744.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-11",24,24,897,,0.002,0.001,430,0.0595,0.025,0.0068,7231.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-12",24,24,1034,,0.002,0.001,481.2,0.0591,0.027,0.0067,8100.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-13",24,24,1006,,0.002,0.001,471.3,0.059,0.027,0.0069,7938,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-14",24,24,940,,0.002,0.001,447.6,0.0592,0.026,0.0069,7532.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-15",24,24,974,,0.002,0.001,458.1,0.059,0.027,0.0069,7709.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-16",24,24,971,,0.002,0.001,458.5,0.0593,0.025,0.0066,7713,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-17",24,24,865,,0.002,0.001,417.7,0.0592,0.023,0.0066,7030.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-18",24,24,867,,0.002,0.001,417.9,0.0592,0.024,0.0068,7035.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-19",24,24,874,,0.002,0.001,422.1,0.0592,0.024,0.0067,7103.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-20",24,24,865,,0.002,0.001,418.5,0.0595,0.023,0.0065,7037.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-21",24,24,872,,0.002,0.001,421.4,0.0593,0.023,0.0066,7088.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-22",24,24,873,,0.002,0.001,421,0.0592,0.024,0.0068,7087,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-23",24,24,866,,0.002,0.001,417.9,0.0596,0.024,0.0067,7026,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-24",24,24,867,,0.002,0.001,419.1,0.0593,0.023,0.0065,7049.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-25",24,24,865,,0.002,0.001,417.2,0.0593,0.023,0.0065,7023,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-26",24,23.85,847.5,,0.002,0.001,404.77,0.0592,0.023,0.0068,6812.915,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-27",20,19.2,679,,0.002,0.001,334.7,0.0593,0.03,0.0167,5630.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-28",19,17.26,574.6,,0.002,0.001,313.44,0.0593,0.033,0.0199,5272.673,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-29",24,24,892,,0.002,0.001,432.9,0.0594,0.025,0.0068,7281.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-30",24,24,869,,0.002,0.001,424.2,0.0592,0.024,0.0068,7141.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-03-31",24,24,875,,0.002,0.001,425.9,0.0593,0.024,0.0066,7170.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-01",24,24,867,,0.002,0.001,421.2,0.0593,0.024,0.0068,7088.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-02",24,24,864,,0.002,0.001,422.1,0.0593,0.024,0.0069,7101.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-03",24,24,867,,0.002,0.001,422.1,0.0592,0.024,0.0067,7106.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-04",17,15.85,620.01,,0.002,0.001,308.612,0.0592,0.036,0.0209,5192.662,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-05",24,24,972,,0.002,0.001,458.5,0.0591,0.025,0.0064,7719.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-06",24,24,877,,0.002,0.001,425.7,0.0592,0.024,0.0067,7164.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-07",24,24,868,,0.002,0.001,423,0.0591,0.023,0.0066,7119.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-08",24,24,888,,0.002,0.001,432.6,0.0592,0.025,0.0068,7280.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-09",24,24,916,,0.002,0.001,445.4,0.0592,0.025,0.0067,7494.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-10",24,24,867,,0.002,0.001,423.1,0.0592,0.023,0.0066,7122.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-11",24,24,864,,0.002,0.001,421.4,0.0593,0.024,0.0068,7089.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-12",24,24,877,,0.002,0.001,428.6,0.0595,0.023,0.0063,7207.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-13",24,24,864,,0.002,0.001,423.1,0.0591,0.023,0.0065,7121,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-14",24,24,878,,0.002,0.001,430.6,0.0593,0.024,0.0066,7246.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-15",24,24,864,,0.002,0.001,423.9,0.0593,0.022,0.0063,7130.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-16",24,24,865,,0.002,0.001,424.8,0.059,0.024,0.0067,7152,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-17",24,24,868,,0.002,0.001,422.7,0.0593,0.023,0.0065,7112.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-18",24,24,870,,0.002,0.001,424.4,0.0592,0.023,0.0065,7137.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-19",24,24,865,,0.002,0.001,422.4,0.0595,0.023,0.0064,7102.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-20",24,23.2,849.2,,0.002,0.001,413.56,0.0595,0.023,0.0066,6956.02,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-21",24,24,880,,0.002,0.001,428.4,0.0592,0.023,0.0064,7207.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-22",24,24,871,,0.002,0.001,425.2,0.0592,0.023,0.0063,7155,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-23",24,24,868,,0.002,0.001,423.4,0.0592,0.023,0.0063,7122.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-24",24,24,892,,0.002,0.001,431.4,0.0593,0.024,0.0066,7261.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-25",24,24,868,,0.002,0.001,423.8,0.0595,0.024,0.0068,7125.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-26",24,24,879,,0.002,0.001,428.7,0.0593,0.025,0.0069,7213.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-27",24,24,872,,0.002,0.001,427.1,0.0593,0.025,0.007,7185.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-28",24,24,876,,0.002,0.001,428.3,0.0591,0.025,0.0069,7211.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-29",24,24,868,,0.002,0.001,423.2,0.0597,0.025,0.007,7115.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-04-30",24,24,866,,0.002,0.001,424,0.0593,0.025,0.0069,7131.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-01",24,23.37,866.77,,0.002,0.001,419.506,0.0595,0.024,0.0076,7052.288,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-04",21,20.95,888.65,,0.002,0.001,432.185,0.0593,0.043,0.016,7272.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-05",24,24,923,,0.002,0.001,440.4,0.0592,0.026,0.0069,7413.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-06",24,24,926,,0.002,0.001,442.6,0.0592,0.025,0.0068,7450.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-07",24,24,993,,0.002,0.001,470,0.0593,0.027,0.0068,7909.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-08",24,24,922,,0.002,0.001,439.2,0.0595,0.026,0.007,7388.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-09",24,24,947,,0.002,0.001,448.6,0.0594,0.026,0.007,7545.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-10",24,24,872,,0.002,0.001,418.3,0.0593,0.024,0.007,7034.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-11",24,24,908,,0.002,0.001,434.4,0.0594,0.025,0.007,7307.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-12",24,24,894,,0.002,0.001,429.3,0.0594,0.025,0.007,7225,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-13",24,24,894,,0.002,0.001,430.9,0.0594,0.025,0.0069,7246.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-14",24,24,897,,0.002,0.001,432.1,0.0592,0.025,0.0069,7272.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-15",24,24,873,,0.002,0.001,422.9,0.0595,0.025,0.007,7113.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-16",24,24,941,,0.002,0.001,448.9,0.0593,0.026,0.0068,7552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-17",24,24,905,,0.002,0.001,433.8,0.0592,0.025,0.0069,7304.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-18",24,24,888,,0.002,0.001,428.7,0.0596,0.025,0.0069,7204.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-19",24,24,864,,0.002,0.001,419.9,0.0593,0.024,0.0069,7063.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-20",24,24,864,,0.002,0.001,420.6,0.0593,0.025,0.007,7077,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-21",22,21.37,765.21,,0.002,0.001,375.038,0.0595,0.021,0.0067,6306.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-22",23,22.63,805.19,,0.002,0.001,394.067,0.0594,0.03,0.0118,6627.764,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-23",20,18.61,672.98,,0.002,0.001,330.08,0.0594,0.028,0.0116,5550.419,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-24",24,24,880,,0.002,0.001,427,0.0592,0.025,0.0069,7186.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-25",24,24,964,,0.002,0.001,458.4,0.0591,0.027,0.0069,7721,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-26",24,24,979,,0.002,0.001,463.3,0.0595,0.027,0.0069,7794.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-27",24,24,949,,0.002,0.001,452.1,0.0593,0.026,0.007,7606.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-28",24,24,909,,0.002,0.001,437.4,0.0592,0.026,0.007,7361.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-29",24,24,963,,0.002,0.001,458,0.059,0.027,0.0069,7710.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-30",24,24,919,,0.002,0.001,440.5,0.0593,0.026,0.007,7408.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-05-31",24,24,898,,0.002,0.001,433.8,0.0591,0.025,0.0069,7303.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-01",24,24,898,,0.002,0.001,429.8,0.0593,0.025,0.0069,7232.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-02",24,24,950,,0.002,0.001,448.9,0.0595,0.026,0.0069,7550.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-03",24,24,964,,0.002,0.001,454.4,0.0591,0.026,0.0069,7648.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-04",24,24,871,,0.002,0.001,419.4,0.0591,0.025,0.007,7063.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-05",24,24,869,,0.002,0.001,418.3,0.0593,0.024,0.0069,7042.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-06",24,24,866,,0.002,0.001,418.6,0.0598,0.025,0.007,7035.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-07",24,24,867,,0.002,0.001,419,0.0595,0.024,0.0069,7046.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-08",24,24,938,,0.002,0.001,446.1,0.0592,0.025,0.0068,7507,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-09",24,24,953,,0.002,0.001,452.9,0.0594,0.026,0.0067,7618.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-10",24,24,992,,0.002,0.001,465.3,0.0592,0.026,0.0066,7834.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-11",24,24,947,,0.002,0.001,448.2,0.0591,0.025,0.0067,7545.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-12",24,24,880,,0.002,0.001,424.3,0.0594,0.025,0.0069,7137.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-13",24,24,878,,0.002,0.001,421.6,0.0594,0.024,0.0068,7095.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-14",24,24,896,,0.002,0.001,427.5,0.0591,0.025,0.0068,7202.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-15",24,24,917,,0.002,0.001,436.3,0.0593,0.025,0.0069,7343.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-16",24,24,920,,0.002,0.001,438.6,0.0594,0.026,0.007,7376.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-17",24,24,868,,0.002,0.001,417.7,0.0591,0.024,0.0068,7037.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-18",24,24,876,,0.002,0.001,422.4,0.0597,0.025,0.007,7099.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-19",24,24,894,,0.002,0.001,429.2,0.0595,0.025,0.0069,7220,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-20",24,24,892,,0.002,0.001,428.1,0.0596,0.025,0.0069,7198.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-21",24,24,901,,0.002,0.001,429.5,0.0591,0.025,0.007,7237,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-22",24,24,950,,0.002,0.001,448.5,0.0592,0.026,0.007,7553.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-23",24,24,914,,0.002,0.001,436.1,0.0594,0.026,0.007,7337,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-24",24,24,978,,0.002,0.001,458.2,0.0593,0.027,0.007,7708.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-25",24,24,918,,0.002,0.001,438.9,0.0594,0.026,0.007,7382,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-26",24,24,960,,0.002,0.001,452.7,0.0595,0.026,0.0069,7612.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-27",24,24,984,,0.002,0.001,462.1,0.0595,0.027,0.0069,7771.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-28",24,24,892,,0.002,0.001,426.9,0.0591,0.025,0.007,7190,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-29",24,24,880,,0.002,0.001,423.6,0.0594,0.025,0.007,7122.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-06-30",24,24,917,,0.002,0.001,437,0.0594,0.025,0.0069,7352.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-01",24,24,886,,0.002,0.001,424,0.059,0.024,0.0068,7142,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-02",24,24,891,,0.002,0.001,426.1,0.059,0.024,0.0068,7175.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-03",22,20.74,735.06,,0.002,0.001,364.844,0.059,0.04,0.023,6147.636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-04",24,24,889,,0.002,0.001,426.8,0.0594,0.024,0.0068,7180.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-05",24,24,899,,0.002,0.001,430.3,0.0592,0.025,0.0069,7242,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-06",24,24,953,,0.002,0.001,449.5,0.0593,0.025,0.0067,7558.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-07",24,24,978,,0.002,0.001,461,0.0593,0.027,0.0068,7755.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-08",24,24,901,,0.002,0.001,429.4,0.0591,0.025,0.0069,7228.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-09",24,24,975,,0.002,0.001,458.1,0.0592,0.027,0.0069,7709.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-10",24,24,1055,,0.002,0.001,486.6,0.0591,0.029,0.007,8193.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-11",24,24,1052,,0.002,0.001,487.9,0.0591,0.028,0.0068,8214.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-12",24,24,1050,,0.002,0.001,487.9,0.0593,0.029,0.007,8206.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-13",24,24,1006,,0.002,0.001,469.2,0.0592,0.027,0.0068,7896.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-14",24,24,918,,0.002,0.001,436.2,0.0592,0.026,0.007,7342,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-15",24,24,911,,0.002,0.001,433,0.0593,0.025,0.007,7282.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-16",24,24,907,,0.002,0.001,431.7,0.0592,0.025,0.007,7262.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-17",24,24,914,,0.002,0.001,435,0.0592,0.025,0.007,7316,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-18",24,24,887,,0.002,0.001,423.6,0.0593,0.025,0.007,7121.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-19",24,24,864,,0.002,0.001,415.3,0.0592,0.024,0.007,6983.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-20",24,24,879,,0.002,0.001,421.5,0.0591,0.025,0.007,7092.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-21",24,24,892,,0.002,0.001,426.5,0.0592,0.025,0.007,7174.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-22",24,24,879,,0.002,0.001,421.6,0.0592,0.025,0.007,7090.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-23",24,24,874,,0.002,0.001,419.9,0.059,0.024,0.0069,7069.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-24",24,24,885,,0.002,0.001,424.2,0.0591,0.025,0.007,7139.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-25",24,23.17,867.4,,0.002,0.001,414.774,0.0593,0.024,0.0082,6980.137,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-26",8,7.97,308.49,,0.001,0.001,148.043,0.0593,0.02,0.0224,2491.606,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-27",24,24,928,,0.002,0.001,439.1,0.059,0.026,0.0069,7395.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-28",24,24,903,,0.002,0.001,431.1,0.0594,0.025,0.007,7253.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-29",24,24,949,,0.002,0.001,446.4,0.0591,0.026,0.007,7512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-30",24,24,1029,,0.002,0.001,478.9,0.0592,0.028,0.0069,8057.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-07-31",24,24,1086,,0.003,0.001,500.4,0.0592,0.029,0.007,8419.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-01",24,24,915,,0.002,0.001,436.6,0.0593,0.023,0.0063,7343.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-02",24,24,1219,,0.003,0.001,556.2,0.059,0.033,0.007,9363.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-03",24,24,890,,0.002,0.001,425.7,0.059,0.025,0.007,7173.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-04",24,24,864,,0.002,0.001,416.5,0.0595,0.024,0.007,7004.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-05",24,24,868,,0.002,0.001,418.1,0.0593,0.024,0.007,7036.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-06",24,24,864,,0.002,0.001,416.5,0.0591,0.024,0.0069,7013,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-07",24,24,893,,0.002,0.001,428,0.0593,0.025,0.007,7200.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-08",24,24,873,,0.002,0.001,422.9,0.0593,0.025,0.007,7118,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-09",24,24,892,,0.002,0.001,428.5,0.0593,0.025,0.0069,7209.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-10",24,24,908,,0.002,0.001,435,0.0595,0.025,0.007,7315.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-11",24,24,893,,0.002,0.001,428,0.0595,0.025,0.007,7197.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-12",24,24,987,,0.002,0.001,460.7,0.0592,0.027,0.007,7753.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-13",24,24,1146,,0.003,0.001,525.2,0.0593,0.03,0.0068,8838.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-14",24,24,1170,,0.003,0.001,531.8,0.0592,0.031,0.007,8951.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-15",24,24,1207,,0.003,0.001,545.1,0.0592,0.031,0.0068,9174.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-16",24,24,1008,,0.002,0.001,469.2,0.0592,0.027,0.0068,7895.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-17",24,24,1285,,0.003,0.001,572.1,0.0593,0.034,0.007,9622.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-18",24,24,1013,,0.002,0.001,472.4,0.0592,0.027,0.0069,7948.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-19",24,24,1142,,0.003,0.001,527.9,0.0593,0.031,0.0069,8882.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-20",24,24,1074,,0.003,0.001,498.1,0.0592,0.029,0.0069,8382.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-21",24,24,1082,,0.003,0.001,510.1,0.0594,0.03,0.0069,8579.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-22",24,24,1008,,0.002,0.001,478.9,0.059,0.027,0.0068,8063.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-23",24,24,1073,,0.003,0.001,495.7,0.0595,0.029,0.0069,8333.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-24",24,24,1107,,0.003,0.001,510.2,0.0593,0.029,0.0068,8585,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-25",24,24,1024,,0.002,0.001,474.3,0.0591,0.026,0.0065,7987.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-26",24,24,1018,,0.002,0.001,472.9,0.059,0.024,0.006,7961.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-27",24,24,1099,,0.003,0.001,505.9,0.0594,0.026,0.006,8509.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-28",24,24,1003,,0.002,0.001,469.7,0.0591,0.024,0.006,7904.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-29",22,21.17,770.44,,0.002,0.001,369.505,0.0592,0.019,0.006,6219.375,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-30",17,16.62,581.2,,0.001,0.001,284.076,0.0594,0.027,0.0164,4778.252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-08-31",24,24,864,,0.002,0.001,415.2,0.0592,0.021,0.006,6986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-01",24,24,874,,0.002,0.001,422.4,0.0592,0.021,0.006,7113.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-02",24,24,853,,0.002,0.001,421.9,0.0592,0.021,0.006,7101.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-03",24,24,994,,0.002,0.001,465,0.0591,0.023,0.006,7826.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-04",24,24,1078,,0.003,0.001,502.6,0.0592,0.025,0.006,8459.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-05",24,24,1171,,0.003,0.001,539.1,0.0593,0.027,0.006,9071.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-06",24,24,1130,,0.003,0.001,525.3,0.0594,0.027,0.006,8834.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-07",24,24,901,,0.002,0.001,432.3,0.0593,0.022,0.006,7273.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-08",24,24,879,,0.002,0.001,422.7,0.0594,0.021,0.006,7109,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-09",24,24,871,,0.002,0.001,419.1,0.0593,0.021,0.006,7054.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-10",24,24,893,,0.002,0.001,428.8,0.0592,0.022,0.006,7217.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-11",24,24,898,,0.002,0.001,430.3,0.0593,0.022,0.006,7241.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-12",24,24,907,,0.002,0.001,434,0.0593,0.022,0.006,7305.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-13",24,24,878,,0.002,0.001,421.5,0.0594,0.021,0.006,7089.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-14",24,24,955,,0.002,0.001,450.2,0.0593,0.023,0.006,7574.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-15",24,24,968,,0.002,0.001,456.8,0.0595,0.025,0.0065,7681.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-16",24,24,998,,0.002,0.001,471.5,0.0592,0.027,0.0068,7933.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-17",24,24,1023,,0.002,0.001,478.2,0.0593,0.027,0.0067,8043.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-18",24,24,1058,,0.003,0.001,496.2,0.0593,0.028,0.0066,8349.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-19",24,24,956,,0.002,0.001,455.7,0.0592,0.025,0.0066,7670.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-20",24,24,968,,0.002,0.001,456.3,0.0593,0.027,0.0069,7681.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-21",23,21.96,854.69,,0.002,0.001,408.828,0.0593,0.031,0.011,6878.187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-22",24,24,896,,0.002,0.001,431.2,0.0594,0.025,0.0069,7252.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-23",24,24,882,,0.002,0.001,424.9,0.0593,0.024,0.0068,7148.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-24",24,24,864,,0.002,0.001,415.5,0.0591,0.023,0.0065,6995,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-25",24,24,868,,0.002,0.001,417.8,0.0591,0.024,0.0068,7034.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-26",24,24,864,,0.002,0.001,416,0.0593,0.023,0.0066,7000,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-27",24,24,885,,0.002,0.001,424.3,0.0595,0.023,0.0066,7132.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-28",24,24,982,,0.002,0.001,460.8,0.059,0.026,0.0068,7760.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-29",24,24,956,,0.002,0.001,452.7,0.0592,0.026,0.0068,7620.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-09-30",24,24,923,,0.002,0.001,438.3,0.0593,0.024,0.0066,7377.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-01",24,24,934,,0.002,0.001,441.6,0.0594,0.025,0.0066,7429.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-02",24,24,957,,0.002,0.001,447.8,0.0594,0.025,0.0067,7534.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-03",24,24,985,,0.002,0.001,461.3,0.0593,0.027,0.0068,7762,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-04",24,24,1140,,0.003,0.001,524.6,0.0592,0.03,0.0068,8829.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-05",24,24,1110,,0.003,0.001,511.1,0.0593,0.029,0.0068,8598.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-06",24,24,1024,,0.002,0.001,478,0.0594,0.028,0.0069,8037.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-07",24,24,992,,0.002,0.001,465.4,0.0595,0.027,0.0069,7829.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-08",24,24,886,,0.002,0.001,428,0.0593,0.024,0.0068,7205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-09",24,24,900,,0.002,0.001,432.2,0.0593,0.025,0.0068,7272.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-10",24,24,908,,0.002,0.001,433.7,0.0593,0.025,0.0068,7298.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-11",24,24,870,,0.002,0.001,420.5,0.0593,0.024,0.0069,7075.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-12",24,24,1061,,0.002,0.001,494.2,0.0593,0.028,0.0068,8310.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-13",24,24,935,,0.002,0.001,444.1,0.0592,0.025,0.0068,7473.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-14",24,24,1010,,0.002,0.001,475.5,0.0593,0.027,0.0067,7998.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-15",24,24,1000,,0.002,0.001,468.1,0.0592,0.027,0.0068,7876.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-16",24,24,879,,0.002,0.001,420.9,0.0594,0.024,0.0068,7084,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-17",24,24,880,,0.002,0.001,422.7,0.0591,0.024,0.0067,7114.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-18",24,24,904,,0.002,0.001,433.2,0.0593,0.024,0.0067,7287.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-19",24,24,985,,0.002,0.001,462.2,0.059,0.027,0.0068,7782.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-20",24,24,949,,0.002,0.001,447.5,0.0592,0.026,0.007,7532.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-21",24,24,993,,0.002,0.001,464.8,0.059,0.027,0.0068,7826.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-22",24,24,1078,,0.003,0.001,495.9,0.0593,0.029,0.0068,8343.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-23",24,24,976,,0.002,0.001,460.2,0.0593,0.026,0.0068,7740.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-24",24,24,978,,0.002,0.001,459.9,0.0595,0.026,0.0068,7733.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-25",24,24,1007,,0.002,0.001,472.1,0.0592,0.027,0.0068,7945.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-26",24,24,1123,,0.003,0.001,512.5,0.0591,0.029,0.0067,8625.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-27",24,24,1048,,0.002,0.001,484.2,0.0591,0.027,0.0066,8150,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-28",24,24,957,,0.002,0.001,452.3,0.0593,0.025,0.0067,7612.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-29",24,24,977,,0.002,0.001,459.4,0.0593,0.026,0.0068,7730.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-30",24,24,966,,0.002,0.001,455.1,0.0593,0.026,0.0068,7659.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-10-31",24,23.15,834.4,,0.002,0.001,404.19,0.0592,0.023,0.008,6798.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-09",6,5.93,228.23,,0.001,0.001,111.579,0.0592,0.026,0.0423,1878.276,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-10",24,24,967,,0.002,0.001,457.3,0.0593,0.025,0.0065,7692.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-11",24,24,871,,0.002,0.001,418.9,0.0593,0.023,0.0066,7046.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-12",24,24,894,,0.002,0.001,428.8,0.0592,0.024,0.0066,7214.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-13",24,24,870,,0.002,0.001,419.5,0.0594,0.023,0.0064,7060.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-14",24,24,864,,0.002,0.001,420.3,0.0592,0.023,0.0065,7072.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-15",24,24,869,,0.002,0.001,420.7,0.0593,0.024,0.0067,7079.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-16",24,24,911,,0.002,0.001,438.2,0.0594,0.024,0.0065,7373.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-17",24,24,865,,0.002,0.001,420.1,0.0593,0.023,0.0064,7066.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-18",24,24,867,,0.002,0.001,420.6,0.0594,0.023,0.0064,7075.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-19",24,24,873,,0.002,0.001,423.2,0.0592,0.023,0.0064,7124.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-20",24,24,1123,,0.003,0.001,525.1,0.059,0.029,0.0065,8840.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-21",24,24,1392,,0.003,0.001,635,0.0592,0.037,0.007,10683.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-22",24,24,1006,,0.002,0.001,482.3,0.0591,0.027,0.0066,8117.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-23",24,24,867,,0.002,0.001,419.3,0.0591,0.023,0.0065,7060.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-24",24,24,866,,0.002,0.001,420.3,0.0593,0.023,0.0065,7069.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-25",24,24,865,,0.002,0.001,417.6,0.0593,0.023,0.0066,7025.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-26",24,24,867,,0.002,0.001,417.6,0.0592,0.024,0.0068,7028.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-27",24,24,865,,0.002,0.001,417.8,0.0593,0.024,0.0068,7027,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-28",24,24,879,,0.002,0.001,423.4,0.0593,0.025,0.0069,7122.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-29",24,24,895,,0.002,0.001,427.6,0.059,0.025,0.0069,7202,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-11-30",24,24,964,,0.002,0.001,453.7,0.0594,0.026,0.0067,7631.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-01",24,24,965,,0.002,0.001,462.1,0.0594,0.026,0.0068,7773.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-02",24,24,870,,0.002,0.001,426.1,0.0592,0.024,0.0068,7172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-03",24,24,893,,0.002,0.001,435.3,0.0592,0.025,0.0069,7327.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-04",24,24,890,,0.002,0.001,429.8,0.0595,0.025,0.0069,7228.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-05",24,24,867,,0.002,0.001,421.1,0.0594,0.021,0.006,7087.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-06",24,24,871,,0.002,0.001,421.2,0.0596,0.021,0.006,7082.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-07",24,24,871,,0.002,0.001,421.3,0.0593,0.023,0.0066,7090.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-08",24,24,864,,0.002,0.001,419,0.0595,0.024,0.0068,7046.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-09",24,24,864,,0.002,0.001,422.7,0.0592,0.024,0.0066,7110.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-10",24,24,874,,0.002,0.001,426.1,0.0593,0.024,0.0068,7169.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-11",24,24,911,,0.002,0.001,439.2,0.0591,0.025,0.0068,7394.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-12",24,24,1003,,0.002,0.001,474.2,0.0595,0.027,0.0067,7976.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-13",24,24,865,,0.002,0.001,420.3,0.0594,0.023,0.0065,7069.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-14",24,24,870,,0.002,0.001,421.6,0.0595,0.023,0.0065,7094.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-15",24,24,882,,0.002,0.001,425.5,0.0593,0.024,0.0068,7161.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-16",24,24,992,,0.002,0.001,466.8,0.0593,0.027,0.0069,7854.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-17",24,24,864,,0.002,0.001,419,0.0594,0.023,0.0065,7050.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-18",24,24,907,,0.002,0.001,437.4,0.0593,0.024,0.0066,7362.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-19",24,24,878,,0.002,0.001,428.1,0.0593,0.024,0.0065,7201.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-20",24,24,874,,0.002,0.001,422.7,0.0593,0.024,0.0068,7114.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-21",24,24,864,,0.002,0.001,418.2,0.0595,0.024,0.0068,7034.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-22",24,24,871,,0.002,0.001,423.5,0.0593,0.023,0.0064,7127.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-23",24,24,865,,0.002,0.001,420.2,0.0591,0.024,0.0067,7074.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-24",24,23.08,822.24,,0.002,0.001,401.508,0.0598,0.026,0.0129,6747.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-25",20,18.75,672.69,,0.002,0.001,337.004,0.0592,0.038,0.0195,5668.912,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-27",8,7.4,269.2,,0.001,0.001,145.94,0.0593,0.03,0.0485,2456.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-28",24,24,1021,,0.002,0.001,480.6,0.0593,0.027,0.0068,8085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-29",24,24,874,,0.002,0.001,425.9,0.0593,0.024,0.0068,7167,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-30",24,24,864,,0.002,0.001,420.7,0.0593,0.023,0.0066,7077.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Malburg Generating Station",56041,"M2",,"2020-12-31",23,22.28,807.72,,0.002,0.001,392.244,0.0592,0.023,0.0075,6603.736,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-01",24,24,4234,,0.01,0.001,1825.3,0.059,0.077,0.005,30715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-02",24,24,4293,,0.01,0.001,1844.6,0.059,0.078,0.005,31039.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-03",24,24,4323,,0.01,0.001,1854,0.059,0.079,0.0051,31200.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-04",24,24,4254,,0.01,0.001,1835.2,0.059,0.077,0.005,30882.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-05",24,24,4231,,0.01,0.001,1827.5,0.059,0.077,0.005,30754.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-06",24,24,4386,,0.01,0.001,1877,0.059,0.081,0.0051,31585.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-07",24,24,4291,,0.01,0.001,1839.8,0.059,0.078,0.005,30959.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-08",24,24,4238,,0.01,0.001,1824.5,0.059,0.077,0.005,30696.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-09",24,24,4594,,0.01,0.001,1943.9,0.059,0.081,0.005,32708.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-10",24,24,4371,,0.01,0.001,1870.2,0.059,0.078,0.005,31471.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-11",24,24,4220,,0.01,0.001,1820.3,0.059,0.077,0.005,30632.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-12",24,24,4226,,0.01,0.001,1824.4,0.059,0.077,0.005,30694.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-13",24,24,4418,,0.01,0.001,1887.2,0.059,0.079,0.005,31754.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-14",24,24,4448,,0.01,0.001,1899.3,0.059,0.078,0.0049,31957.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-15",24,24,4630,,0.01,0.001,1961.4,0.059,0.083,0.005,33002,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-16",24,24,4578,,0.01,0.001,1943,0.059,0.082,0.005,32698.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-17",24,24,4407,,0.01,0.001,1883.8,0.059,0.079,0.005,31698.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-18",19,18.48,3215.64,,0.007,0.001,1392.024,0.059,0.071,0.0072,23423.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-22",18,17.85,2756.5,,0.006,0.001,1243.21,0.0591,0.116,0.0206,20917.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-23",24,24,5367,,0.011,0.001,2216.4,0.059,0.098,0.0052,37293.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-24",24,24,4939,,0.01,0.001,2061.5,0.059,0.089,0.0051,34685.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-25",24,24,4700,,0.01,0.001,1973,0.059,0.084,0.005,33199.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-26",24,24,4523,,0.01,0.001,1915.5,0.059,0.081,0.005,32227.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-27",24,24,4537,,0.01,0.001,1913.6,0.059,0.083,0.0052,32201.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-28",24,24,4344,,0.01,0.001,1844.5,0.059,0.081,0.0053,31039.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-29",24,24,4581,,0.01,0.001,1923.2,0.059,0.085,0.0053,32360.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-30",24,24,4553,,0.01,0.001,1916.5,0.059,0.085,0.0053,32248,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-01-31",19,18.43,3311.33,,0.007,0.001,1408.218,0.059,0.071,0.007,23700.291,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-21",1,0.3,0,,0,0.001,9,0.059,0,0.002,151.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-25",7,6.37,373.15,,0.001,0.001,268.671,0.0591,0.127,0.0697,4519.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-27",17,16.72,2541.94,,0.006,0.001,1164.325,0.059,0.133,0.0265,19594.808,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-02-29",21,20.1,2587,,0.006,0.001,1236.66,0.059,0.211,0.0293,20807.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-01",24,24,4429,,0.01,0.001,1901.7,0.059,0.08,0.0049,31999.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-02",24,24,4099,,0.009,0.001,1778.1,0.059,0.077,0.0051,29914.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-03",24,24,3976,,0.009,0.001,1754.3,0.059,0.08,0.0052,29519,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-04",19,18.47,3241.76,,0.007,0.001,1411.874,0.059,0.064,0.0049,23755.564,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-12",15,14.4,1910.6,,0.005,0.001,923.64,0.0591,0.109,0.0238,15541.12,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-13",24,24,4719,,0.01,0.001,2009,0.059,0.08,0.0048,33801,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-14",24,24,4811,,0.01,0.001,2032.6,0.059,0.081,0.0048,34203.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-15",24,24,4205,,0.009,0.001,1820.5,0.059,0.078,0.0051,30633.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-16",24,24,5087,,0.011,0.001,2108.7,0.059,0.087,0.0049,35479.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-17",24,24,4785,,0.01,0.001,2006.3,0.059,0.085,0.005,33764.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-18",24,24,4932,,0.01,0.001,2053.1,0.059,0.086,0.005,34543.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-19",24,24,4632,,0.01,0.001,1952.4,0.059,0.081,0.0049,32853.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-20",24,24,4693,,0.01,0.001,1971.1,0.059,0.083,0.005,33164.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-21",24,24,4554,,0.01,0.001,1949.6,0.059,0.083,0.005,32805.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-22",24,24,4581,,0.01,0.001,1958.9,0.059,0.08,0.0049,32960.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-23",24,24,4345,,0.01,0.001,1887.9,0.059,0.077,0.0049,31764.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-24",24,24,3571,,0.008,0.001,1650.1,0.059,0.068,0.005,27767.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-25",24,24,3866,,0.009,0.001,1746.5,0.059,0.074,0.0051,29390.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-26",24,24,3885,,0.009,0.001,1742.6,0.059,0.073,0.005,29321.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-27",24,24,4086,,0.009,0.001,1797.4,0.059,0.077,0.0051,30250.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-28",24,24,4024,,0.009,0.001,1788.5,0.059,0.075,0.005,30097.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-29",24,24,4080,,0.009,0.001,1807.9,0.059,0.078,0.0052,30423.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-30",24,24,3910,,0.009,0.001,1745.8,0.059,0.074,0.005,29375.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-03-31",24,24,3936,,0.009,0.001,1764.1,0.059,0.072,0.0049,29683.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-01",24,24,3937,,0.009,0.001,1756.3,0.059,0.073,0.005,29551.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-02",24,24,4001,,0.009,0.001,1779.4,0.059,0.073,0.005,29940.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-03",24,24,4207,,0.009,0.001,1846.4,0.059,0.08,0.0052,31071.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-04",24,24,4362,,0.01,0.001,1899.2,0.059,0.085,0.0054,31955.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-05",24,24,4912,,0.011,0.001,2052.7,0.059,0.085,0.0049,34541.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-06",24,24,4619,,0.01,0.001,1945.5,0.059,0.081,0.005,32734.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-07",24,24,4350,,0.01,0.001,1881.1,0.059,0.081,0.0052,31647.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-08",24,24,4842,,0.01,0.001,2025.8,0.059,0.085,0.005,34089.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-09",24,24,5037,,0.011,0.001,2092.5,0.059,0.09,0.0051,35207.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-10",24,24,4790,,0.01,0.001,2018.9,0.059,0.086,0.0051,33969.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-11",24,24,4275,,0.009,0.001,1865,0.059,0.081,0.0052,31383.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-12",24,24,4336,,0.01,0.001,1885.8,0.059,0.082,0.0052,31730.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-13",24,24,4353,,0.01,0.001,1893.5,0.059,0.084,0.0053,31860.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-14",24,24,4112,,0.009,0.001,1814.9,0.059,0.079,0.0052,30541.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-15",24,24,4204,,0.009,0.001,1832.1,0.059,0.077,0.005,30824.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-16",24,24,4333,,0.01,0.001,1884.6,0.059,0.08,0.0051,31710,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-17",24,24,4359,,0.01,0.001,1899.6,0.059,0.08,0.005,31961.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-18",24,24,4111,,0.009,0.001,1818.5,0.059,0.078,0.0051,30598.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-19",24,24,4083,,0.009,0.001,1809.4,0.059,0.08,0.0053,30445.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-20",24,24,4038,,0.009,0.001,1785.3,0.059,0.074,0.005,30046.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-21",24,24,3834,,0.009,0.001,1737.5,0.059,0.075,0.0051,29237,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-22",24,24,4089,,0.009,0.001,1820.4,0.059,0.077,0.0051,30630.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-23",24,24,4042,,0.009,0.001,1799.8,0.059,0.077,0.0051,30288.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-24",24,24,4259,,0.009,0.001,1855,0.059,0.079,0.0051,31208.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-25",24,24,4556,,0.01,0.001,1963.3,0.059,0.083,0.0051,33035.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-26",6,5.25,899.75,,0.002,0.001,397.275,0.059,0.016,0.005,6684.825,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-04-30",19,18.77,2490.39,,0.006,0.001,1204.036,0.059,0.099,0.0177,20260.885,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-01",24,24,4325,,0.009,0.001,1864.1,0.059,0.08,0.0051,31363.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-02",24,24,3655,,0.008,0.001,1672.4,0.059,0.074,0.0053,28138.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-03",24,24,3559,,0.008,0.001,1644.8,0.059,0.071,0.0052,27680.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-04",24,24,3862,,0.009,0.001,1738.5,0.059,0.076,0.0053,29252.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-05",24,24,4450,,0.01,0.001,1903.2,0.059,0.081,0.0051,32025.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-06",24,24,3957,,0.009,0.001,1756.3,0.059,0.076,0.0052,29558.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-07",24,24,4185,,0.009,0.001,1818.7,0.059,0.079,0.0052,30600.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-08",24,24,4295,,0.009,0.001,1848,0.059,0.078,0.0051,31090.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-09",24,24,3905,,0.009,0.001,1724.6,0.059,0.074,0.0051,29015.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-10",24,24,4003,,0.009,0.001,1765.9,0.059,0.076,0.0052,29715.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-11",24,24,3959,,0.009,0.001,1757.7,0.059,0.074,0.005,29576.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-12",24,24,3839,,0.009,0.001,1722.5,0.059,0.073,0.0051,28984.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-13",24,24,3794,,0.009,0.001,1715.3,0.059,0.076,0.0053,28862.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-14",24,24,4004,,0.009,0.001,1776.8,0.059,0.077,0.0052,29891.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-15",24,24,3954,,0.009,0.001,1762,0.059,0.076,0.0052,29650,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-16",24,24,4291,,0.01,0.001,1870.2,0.059,0.08,0.0051,31470,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-17",24,24,3862,,0.009,0.001,1743,0.059,0.078,0.0053,29326.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-18",24,24,3633,,0.008,0.001,1666.8,0.059,0.075,0.0054,28050.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-19",24,24,3441,,0.008,0.001,1603.6,0.059,0.07,0.0052,26979.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-20",24,24,3540,,0.008,0.001,1641.2,0.059,0.072,0.0052,27616.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-21",24,24,3858,,0.009,0.001,1734.9,0.059,0.075,0.0051,29193.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-22",24,24,3840,,0.009,0.001,1733.7,0.059,0.075,0.0052,29170.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-23",24,24,3729,,0.009,0.001,1706.5,0.059,0.073,0.0051,28712.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-24",24,24,3692,,0.008,0.001,1693.8,0.059,0.07,0.005,28496.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-25",24,24,3936,,0.009,0.001,1776.6,0.059,0.078,0.0053,29899.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-26",24,24,5940,,0.013,0.001,2504.4,0.059,0.094,0.0045,42138.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-27",24,24,5845,,0.012,0.001,2391.8,0.059,0.098,0.0049,40247.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-28",24,24,5611,,0.012,0.001,2302.9,0.059,0.094,0.0048,38752.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-29",24,24,4821,,0.01,0.001,2028.9,0.059,0.083,0.0049,34140.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-30",24,24,3957,,0.009,0.001,1774.3,0.059,0.076,0.0051,29853.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-05-31",24,24,3821,,0.009,0.001,1730,0.059,0.074,0.0051,29111.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-01",24,24,4371,,0.01,0.001,1891.7,0.059,0.078,0.0049,31832.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-02",24,24,4899,,0.01,0.001,2044.1,0.059,0.084,0.0049,34397.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-03",24,24,4752,,0.01,0.001,1997,0.059,0.084,0.005,33605,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-04",24,24,4243,,0.009,0.001,1833.8,0.059,0.075,0.0049,30861.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-05",24,24,4159,,0.009,0.001,1810.9,0.059,0.075,0.005,30468.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-06",24,24,3631,,0.008,0.001,1662.1,0.059,0.071,0.0051,27969.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-07",24,24,3692,,0.009,0.001,1678.1,0.059,0.071,0.005,28234.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-08",24,24,4146,,0.009,0.001,1794.2,0.059,0.076,0.005,30192.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-09",24,24,4728,,0.01,0.001,1972,0.059,0.078,0.0047,33178.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-10",24,24,4386,,0.01,0.001,1875.9,0.059,0.077,0.0049,31565.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-11",24,24,4441,,0.01,0.001,1898.6,0.059,0.079,0.005,31946.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-12",18,17.47,2898.34,,0.006,0.001,1282.04,0.059,0.055,0.0052,21572.28,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-15",19,18.85,2992.35,,0.007,0.001,1344.185,0.059,0.109,0.0176,22614.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-16",24,24,3942,,0.009,0.001,1746.7,0.059,0.073,0.005,29392.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-17",24,24,3827,,0.009,0.001,1726.8,0.059,0.075,0.0052,29059.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-18",24,24,4151,,0.009,0.001,1811.4,0.059,0.076,0.005,30479.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-19",24,24,4391,,0.01,0.001,1890.4,0.059,0.079,0.005,31810,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-20",24,24,3845,,0.009,0.001,1724.4,0.059,0.074,0.0051,29019.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-21",24,24,3873,,0.009,0.001,1736.2,0.059,0.077,0.0053,29219.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-22",24,24,4738,,0.01,0.001,2004.7,0.059,0.081,0.0048,33729.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-23",24,24,4598,,0.01,0.001,1949.1,0.059,0.083,0.0051,32801.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-24",24,24,5145,,0.011,0.001,2121.4,0.059,0.088,0.0049,35697.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-25",24,24,4521,,0.01,0.001,1933.5,0.059,0.082,0.005,32536.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-26",24,24,4915,,0.01,0.001,2055.2,0.059,0.083,0.0048,34582.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-27",24,24,4806,,0.01,0.001,2014.7,0.059,0.084,0.005,33899.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-28",24,24,4266,,0.01,0.001,1850.1,0.059,0.077,0.005,31133.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-29",24,24,3928,,0.009,0.001,1756.4,0.059,0.074,0.0051,29554.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-06-30",24,24,4049,,0.009,0.001,1801.3,0.059,0.076,0.005,30311.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-01",24,24,4611,,0.01,0.001,1958.3,0.059,0.082,0.005,32952.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-02",24,24,4463,,0.01,0.001,1919,0.059,0.083,0.0052,32288,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-03",24,24,4818,,0.01,0.001,2029.7,0.059,0.088,0.0052,34150.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-04",24,24,4708,,0.01,0.001,1993.4,0.059,0.079,0.0048,33542.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-05",24,24,4515,,0.01,0.001,1937,0.059,0.081,0.005,32593.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-06",24,24,4842,,0.01,0.001,2030.9,0.059,0.086,0.0051,34170.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-07",24,24,4722,,0.01,0.001,1987,0.059,0.083,0.005,33437.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-08",24,24,4451,,0.01,0.001,1917.2,0.059,0.097,0.006,32264.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-09",24,24,4592,,0.01,0.001,1956.7,0.059,0.099,0.006,32924.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-10",24,24,4685,,0.01,0.001,1999,0.059,0.101,0.006,33637.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-11",24,24,4869,,0.01,0.001,2039.2,0.059,0.103,0.006,34310,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-12",24,24,4680,,0.01,0.001,1983.3,0.059,0.1,0.006,33374.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-13",24,24,4511,,0.01,0.001,1923.5,0.059,0.097,0.006,32363.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-14",24,24,4450,,0.01,0.001,1902.3,0.059,0.096,0.006,32009.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-15",24,24,4218,,0.009,0.001,1828.9,0.059,0.092,0.006,30777.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-16",24,24,4299,,0.009,0.001,1861.6,0.059,0.094,0.006,31324.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-17",24,24,4448,,0.009,0.001,1907.5,0.059,0.096,0.006,32099.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-18",24,24,4737,,0.01,0.001,1998.4,0.059,0.101,0.006,33620.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-19",24,24,4504,,0.01,0.001,1915.5,0.059,0.097,0.006,32229,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-20",24,24,4600,,0.01,0.001,1953,0.059,0.099,0.006,32866.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-21",24,24,4469,,0.01,0.001,1915.7,0.059,0.097,0.006,32233.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-22",24,24,4402,,0.01,0.001,1901.6,0.059,0.096,0.006,32000.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-23",24,24,4449,,0.01,0.001,1915.4,0.059,0.097,0.006,32229,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-24",24,24,4578,,0.01,0.001,1951.9,0.059,0.091,0.0056,32848.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-25",24,24,4683,,0.01,0.001,1979.9,0.059,0.084,0.005,33317.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-26",24,24,5025,,0.011,0.001,2100.5,0.059,0.089,0.005,35344.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-27",24,24,4926,,0.01,0.001,2049.5,0.059,0.084,0.0049,34483.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-28",24,24,4514,,0.01,0.001,1925.6,0.059,0.08,0.005,32401.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-29",24,24,4661,,0.01,0.001,1987.5,0.059,0.081,0.0048,33439,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-30",24,24,4749,,0.01,0.001,2008.7,0.059,0.083,0.0049,33797,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-07-31",24,24,4752,,0.01,0.001,2004.7,0.059,0.085,0.0051,33733.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-01",24,24,4592,,0.01,0.001,1957.3,0.059,0.082,0.005,32940.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-02",24,24,4416,,0.01,0.001,1908.8,0.059,0.083,0.0052,32119.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-03",24,24,4469,,0.01,0.001,1932.2,0.059,0.081,0.005,32511.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-04",24,24,4476,,0.01,0.001,1934.2,0.059,0.081,0.005,32547.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-05",24,24,4586,,0.01,0.001,1960.2,0.059,0.083,0.005,32982.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-06",24,24,4424,,0.01,0.001,1900.6,0.059,0.081,0.0051,31979.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-07",24,24,4508,,0.01,0.001,1944.4,0.059,0.081,0.005,32716.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-08",24,24,4633,,0.01,0.001,1966.2,0.059,0.084,0.0051,33085.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-09",24,24,4747,,0.01,0.001,2011.6,0.059,0.082,0.0049,33850.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-10",24,24,4911,,0.01,0.001,2057.8,0.059,0.086,0.005,34629.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-11",24,24,4303,,0.009,0.001,1859.2,0.059,0.078,0.005,31282.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-12",24,24,4665,,0.01,0.001,1986.6,0.059,0.081,0.0049,33433.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-13",24,24,4771,,0.01,0.001,2013.3,0.059,0.085,0.0051,33876.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-14",24,24,4652,,0.01,0.001,1984.6,0.059,0.082,0.005,33395.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-15",24,23.98,4629.38,,0.01,0.001,1966.006,0.059,0.082,0.005,33080.842,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-16",24,24,4404,,0.009,0.001,1889.1,0.059,0.079,0.005,31787.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-17",24,24,4787,,0.01,0.001,2026.7,0.059,0.086,0.0051,34100.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-18",24,24,4481,,0.01,0.001,1931.1,0.059,0.079,0.0049,32494.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-19",24,24,4668,,0.01,0.001,1980.6,0.059,0.086,0.0052,33323.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-20",24,24,4471,,0.01,0.001,1917.7,0.059,0.083,0.0052,32268.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-21",24,24,4530,,0.01,0.001,1941.2,0.059,0.082,0.005,32662.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-22",24,24,4735,,0.01,0.001,2000,0.059,0.082,0.0049,33657,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-23",24,24,4857,,0.01,0.001,2044.1,0.059,0.086,0.005,34392.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-24",24,24,5179,,0.011,0.001,2154.8,0.059,0.088,0.0049,36257.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-25",24,24,4803,,0.01,0.001,2028,0.059,0.082,0.0048,34123,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-26",24,24,4750,,0.01,0.001,1998.7,0.059,0.083,0.0049,33630.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-27",24,24,4931,,0.01,0.001,2063.3,0.059,0.083,0.0048,34718.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-28",24,24,4674,,0.01,0.001,1978.8,0.059,0.08,0.0048,33295.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-29",24,24,4381,,0.01,0.001,1902.8,0.059,0.08,0.005,32023.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-30",24,24,4246,,0.009,0.001,1856.5,0.059,0.076,0.0049,31239.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-08-31",24,24,4378,,0.009,0.001,1891.2,0.059,0.077,0.0049,31822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-01",24,24,4543,,0.01,0.001,1953.3,0.059,0.074,0.0045,32867.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-02",24,24,4579,,0.01,0.001,1967.4,0.059,0.078,0.0048,33102.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-03",24,24,4627,,0.01,0.001,1993.6,0.059,0.079,0.0048,33547.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-04",24,24,4673,,0.01,0.001,2024.5,0.059,0.08,0.0047,34068.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-05",12,11.37,1656.12,,0.004,0.001,777.435,0.059,0.035,0.0053,13083.122,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-06",20,19.2,3607.8,,0.008,0.001,1559.38,0.059,0.12,0.0163,26243.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-07",24,24,4441,,0.01,0.001,1914.8,0.059,0.075,0.0047,32219.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-08",24,24,3871,,0.009,0.001,1740.7,0.059,0.073,0.005,29292.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-09",24,24,4273,,0.009,0.001,1835.8,0.059,0.072,0.0047,30884.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-10",24,24,4807,,0.01,0.001,2009.8,0.059,0.08,0.0047,33820.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-11",18,17.45,3620.45,,0.008,0.001,1504.11,0.059,0.06,0.0049,25310.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-14",19,18.88,3430.44,,0.008,0.001,1483.068,0.059,0.119,0.0182,24957.756,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-15",24,24,4619,,0.01,0.001,1957.2,0.059,0.083,0.005,32932,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-16",24,24,4852,,0.01,0.001,2028.9,0.059,0.086,0.005,34142.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-17",24,24,4884,,0.01,0.001,2034.1,0.059,0.085,0.005,34229.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-18",24,24,5172,,0.011,0.001,2131.3,0.059,0.088,0.0049,35864.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-19",24,24,4826,,0.01,0.001,2025.5,0.059,0.084,0.005,34083,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-20",24,24,4953,,0.011,0.001,2069.8,0.059,0.089,0.0051,34826.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-21",24,24,4531,,0.01,0.001,1928.6,0.059,0.081,0.005,32445.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-22",24,24,4594,,0.01,0.001,1953.6,0.059,0.083,0.0051,32874.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-23",24,24,4545,,0.01,0.001,1944.8,0.059,0.084,0.0052,32723.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-24",24,24,4617,,0.01,0.001,1964.2,0.059,0.084,0.0051,33054.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-25",24,24,4709,,0.01,0.001,1999.6,0.059,0.084,0.005,33649.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-26",24,24,4543,,0.01,0.001,1940.1,0.059,0.081,0.005,32646.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-27",24,24,4777,,0.01,0.001,2016.8,0.059,0.085,0.005,33938.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-28",24,24,4803,,0.01,0.001,2023.4,0.059,0.08,0.0048,34051.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-29",19,18.97,3478.26,,0.007,0.001,1496.688,0.059,0.063,0.005,25182.859,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-09-30",2,0.91,0,,0,0.0005,15.938,0.0595,0.019,0.123,268.065,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-01",19,18.47,3452,,0.007,0.001,1479.199,0.0591,0.126,0.0207,24893.509,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-02",24,24,4704,,0.01,0.001,1983.2,0.059,0.084,0.0051,33371,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-03",24,24,4949,,0.011,0.001,2067.6,0.059,0.086,0.005,34789.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-04",24,24,5044,,0.011,0.001,2089.9,0.059,0.086,0.0049,35167.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-05",24,24,5154,,0.011,0.001,2113.8,0.059,0.084,0.0047,35568.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-06",24,24,4490,,0.01,0.001,1909.2,0.059,0.082,0.0051,32129.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-07",24,24,4816,,0.01,0.001,2024.7,0.059,0.083,0.0049,34066.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-08",24,24,4811,,0.01,0.001,2019.7,0.059,0.085,0.005,33984.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-09",24,24,4839,,0.01,0.001,2022.3,0.059,0.084,0.005,34033.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-10",24,24,4265,,0.009,0.001,1847.6,0.059,0.079,0.0051,31090.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-11",24,24,4464,,0.01,0.001,1924.5,0.059,0.078,0.0049,32386.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-12",24,24,4811,,0.01,0.001,2015.6,0.059,0.085,0.005,33915.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-13",24,24,4110,,0.009,0.001,1811.7,0.059,0.08,0.0053,30480.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-14",24,24,5000,,0.011,0.001,2074.5,0.059,0.087,0.005,34905.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-15",24,24,4636,,0.01,0.001,1935.8,0.059,0.081,0.005,32576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-16",24,24,4738,,0.01,0.001,1965.9,0.059,0.083,0.005,33082,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-17",24,24,4851,,0.01,0.001,2014.8,0.059,0.087,0.0051,33905.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-18",24,24,4730,,0.01,0.001,1983,0.059,0.084,0.005,33370.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-19",24,24,4891,,0.01,0.001,2035.6,0.059,0.086,0.005,34247.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-20",24,24,4890,,0.011,0.001,2065.7,0.059,0.084,0.0049,34757.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-21",24,24,4904,,0.01,0.001,2055,0.059,0.083,0.0049,34580,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-22",24,24,4540,,0.01,0.001,1930.2,0.059,0.081,0.005,32478.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-23",24,24,4987,,0.011,0.001,2073.5,0.059,0.087,0.005,34891,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-24",24,24,5149,,0.011,0.001,2133.3,0.059,0.089,0.005,35896.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-25",24,24,5077,,0.011,0.001,2105.6,0.059,0.088,0.005,35428.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-26",24,24,5224,,0.011,0.001,2135.8,0.059,0.091,0.005,35940,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-27",24,24,5314,,0.011,0.001,2170.2,0.059,0.089,0.0049,36522.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-28",24,24,5345,,0.011,0.001,2191.1,0.059,0.09,0.0049,36865.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-29",24,24,5403,,0.011,0.001,2211.4,0.059,0.094,0.005,37210.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-30",24,24,5205,,0.011,0.001,2148.5,0.059,0.087,0.0048,36154.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-10-31",24,24,5147,,0.011,0.001,2126.1,0.059,0.089,0.005,35775.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-01",24,24,5037,,0.011,0.001,2123,0.059,0.087,0.0049,35720.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-02",24,24,5266,,0.011,0.001,2195.8,0.059,0.089,0.0048,36950.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-03",24,24,4495,,0.01,0.001,1936.4,0.059,0.083,0.0051,32581.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-04",24,24,4670,,0.01,0.001,2010.6,0.059,0.082,0.0049,33831.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-05",24,24,5224,,0.011,0.001,2217.2,0.059,0.091,0.0049,37304.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-06",24,24,4818,,0.01,0.001,2035.6,0.059,0.082,0.0048,34254.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-07",24,24,4724,,0.01,0.001,2002,0.059,0.083,0.0049,33688.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-08",24,24,3894,,0.009,0.001,1754,0.059,0.079,0.0054,29513.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-09",24,24,4480,,0.01,0.001,1930.9,0.059,0.081,0.005,32495,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-10",24,24,4219,,0.009,0.001,1857,0.059,0.077,0.005,31249.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-11",24,24,4050,,0.009,0.001,1799.8,0.059,0.078,0.0052,30285.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-12",24,24,3946,,0.009,0.001,1767.9,0.059,0.078,0.0053,29746.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-13",24,24,3623,,0.009,0.001,1677.5,0.059,0.077,0.0055,28229,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-14",24,24,3533,,0.009,0.001,1657.4,0.059,0.075,0.0054,27889.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-15",24,24,3698,,0.009,0.001,1677.7,0.059,0.074,0.0053,28232.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-16",24,24,3988,,0.009,0.001,1770,0.059,0.076,0.0051,29783.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-17",24,24,3774,,0.009,0.001,1735.4,0.059,0.079,0.0055,29204.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-18",24,24,3762,,0.009,0.001,1712.4,0.059,0.075,0.0053,28814.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-19",24,24,3797,,0.009,0.001,1748,0.059,0.078,0.0053,29415.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-20",24,24,4053,,0.009,0.001,1801.9,0.059,0.076,0.0051,30323.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-21",24,24,3951,,0.009,0.001,1768,0.059,0.074,0.005,29751.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-22",24,24,3882,,0.009,0.001,1744.8,0.059,0.076,0.0052,29362.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-23",24,24,4058,,0.009,0.001,1805.6,0.059,0.079,0.0053,30381.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-24",24,24,3532,,0.009,0.001,1647.3,0.059,0.076,0.0055,27720.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-25",24,24,3635,,0.009,0.001,1690.9,0.059,0.074,0.0053,28454.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-26",24,24,3800,,0.009,0.001,1745.5,0.059,0.076,0.0052,29370,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-27",24,24,3699,,0.009,0.001,1697.1,0.059,0.078,0.0055,28555.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-28",24,24,4264,,0.009,0.001,1863.6,0.059,0.076,0.0049,31359.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-29",24,24,4269,,0.009,0.001,1875.7,0.059,0.078,0.005,31557.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-11-30",24,24,4269,,0.009,0.001,1864.6,0.059,0.079,0.005,31374.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-01",24,24,3752,,0.009,0.001,1705.3,0.059,0.072,0.0051,28697.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-02",24,24,3742,,0.008,0.001,1694.7,0.059,0.072,0.0051,28520.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-03",24,24,4739,,0.01,0.001,2044,0.059,0.082,0.0048,34394.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-04",24,24,3911,,0.009,0.001,1765.4,0.059,0.078,0.0053,29708.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-05",24,24,3729,,0.009,0.001,1714.7,0.059,0.072,0.005,28857.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-06",24,24,3913,,0.009,0.001,1764.3,0.059,0.075,0.0051,29690.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-07",24,24,3771,,0.008,0.001,1713.2,0.059,0.074,0.0052,28825.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-08",24,24,3828,,0.009,0.001,1730.3,0.059,0.075,0.0052,29119.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-09",24,24,3727,,0.008,0.001,1699.6,0.059,0.073,0.0051,28602.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-10",24,24,3733,,0.009,0.001,1698.3,0.059,0.075,0.0053,28578.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-11",24,24,3628,,0.009,0.001,1689.5,0.059,0.076,0.0054,28429.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-12",24,24,3424,,0.008,0.001,1628.5,0.059,0.074,0.0055,27399.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-13",24,24,3873,,0.009,0.001,1757.3,0.059,0.073,0.005,29570.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-14",24,24,3603,,0.008,0.001,1683.9,0.059,0.072,0.0052,28334.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-15",24,24,3387,,0.008,0.001,1611.2,0.059,0.074,0.0055,27111.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-16",24,24,3449,,0.008,0.001,1630.5,0.059,0.077,0.0056,27436.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-17",24,24,3471,,0.008,0.001,1635.3,0.059,0.074,0.0054,27515.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-18",24,24,3399,,0.008,0.001,1621.2,0.059,0.075,0.0055,27276.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-19",24,24,3428,,0.008,0.001,1626.7,0.059,0.075,0.0055,27366.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-20",24,24,3610,,0.009,0.001,1682.4,0.059,0.073,0.0052,28311.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-21",24,24,3431,,0.008,0.001,1623.5,0.059,0.071,0.0052,27319.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-22",24,24,4280,,0.01,0.001,1926,0.059,0.076,0.0049,32404.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-23",24,24,3533,,0.008,0.001,1645.8,0.059,0.075,0.0054,27695.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-24",24,24,4026,,0.009,0.001,1797.3,0.059,0.074,0.005,30242.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-25",24,24,3280,,0.008,0.001,1584.6,0.059,0.072,0.0054,26664.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-26",24,24,3234,,0.008,0.001,1577.7,0.059,0.075,0.0057,26548.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-27",24,24,3337,,0.008,0.001,1602.1,0.059,0.073,0.0054,26957.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-28",24,24,4028,,0.009,0.001,1804.2,0.059,0.076,0.005,30361.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-29",24,24,3923,,0.009,0.001,1775.1,0.059,0.076,0.0051,29866.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-30",24,24,3777,,0.009,0.001,1726.8,0.059,0.075,0.0052,29059.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Magnolia Power Project",56046,"1",,"2020-12-31",24,24,3873,,0.009,0.001,1756.5,0.059,0.075,0.0052,29553.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-01",24,24,2418,,0.006,0.001,1173.8,0.059,0.064,0.0065,19750.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-02",24,24,2419,,0.006,0.001,1176.8,0.059,0.063,0.0063,19803.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-03",24,24,2554,,0.006,0.001,1233.3,0.059,0.063,0.006,20752.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-04",24,24,2438,,0.006,0.001,1186.2,0.059,0.06,0.006,19961.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-05",24,24,2439,,0.006,0.001,1189,0.059,0.06,0.006,20005.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-06",24,24,2575,,0.006,0.001,1239.8,0.059,0.07,0.0067,20867,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-07",24,24,2555,,0.006,0.001,1236.8,0.059,0.071,0.0068,20813.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-08",24,24,2556,,0.006,0.001,1234.2,0.059,0.067,0.0065,20770.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-09",24,24,2616,,0.006,0.001,1253.5,0.059,0.067,0.0063,21095.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-10",24,24,2614,,0.006,0.001,1255,0.059,0.067,0.0063,21113.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-11",24,24,2460,,0.006,0.001,1195.5,0.059,0.065,0.0064,20119.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-12",24,24,2536,,0.006,0.001,1223.7,0.059,0.066,0.0064,20594.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-13",24,24,2561,,0.006,0.001,1233.6,0.059,0.065,0.0063,20761.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-14",24,24,2551,,0.006,0.001,1229.6,0.059,0.063,0.0061,20690.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-15",24,24,2667,,0.006,0.001,1271.9,0.059,0.072,0.0067,21403.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-16",24,24,2722,,0.007,0.001,1294.9,0.059,0.069,0.0063,21790.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-17",24,24,2572,,0.006,0.001,1242.3,0.059,0.066,0.0063,20910.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-18",24,24,2535,,0.006,0.001,1224,0.059,0.063,0.0061,20594.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-19",24,24,2646,,0.006,0.001,1271.8,0.059,0.071,0.0066,21403.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-20",24,24,2633,,0.006,0.001,1264.2,0.059,0.068,0.0064,21271.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-21",24,24,2530,,0.006,0.001,1238.5,0.059,0.064,0.0061,20840.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-22",24,24,2501,,0.006,0.001,1209.1,0.059,0.061,0.006,20339.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-23",24,23.05,2287.3,,0.006,0.001,1120.565,0.059,0.059,0.0101,18850.355,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-04",21,20.47,2089.93,,0.005,0.001,1020.071,0.059,0.092,0.0174,17160.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-05",24,23.05,2421.3,,0.006,0.001,1168.22,0.059,0.062,0.0104,19658.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-11",4,3.27,221.43,,0.001,0.001,123.172,0.0593,0.043,0.0578,2073.368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-12",24,24,2578,,0.006,0.001,1234,0.059,0.065,0.0063,20759.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-13",24,24,2545,,0.006,0.001,1220.5,0.059,0.063,0.0062,20530.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-14",24,24,2578,,0.006,0.001,1234.6,0.059,0.064,0.0062,20776.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-15",23,22.57,2355.19,,0.006,0.001,1132.732,0.059,0.059,0.0065,19064.025,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-18",4,3.2,231.8,,0.001,0.001,126.3,0.0593,0.04,0.053,2124.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-19",24,24,2561,,0.006,0.001,1229.9,0.059,0.065,0.0063,20697.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-20",24,24,2632,,0.006,0.001,1258.1,0.059,0.066,0.0062,21172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-21",24,24,2712,,0.006,0.001,1279.8,0.059,0.067,0.0062,21532.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-22",23,22.58,2331.76,,0.006,0.001,1113.326,0.059,0.059,0.0065,18730.166,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-25",3,2.22,113.76,,0,0.001,72.75,0.0593,0.032,0.065,1223.576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-26",24,24,2596,,0.006,0.001,1238.1,0.059,0.068,0.0065,20829.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-27",24,24,2547,,0.006,0.001,1215.4,0.059,0.065,0.0064,20451.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-28",24,24,2437,,0.006,0.001,1178.9,0.059,0.063,0.0063,19836.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-02-29",24,24,2430,,0.006,0.001,1207.3,0.059,0.063,0.0063,20311.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-01",24,24,2430,,0.006,0.001,1209,0.059,0.061,0.006,20341.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-02",24,24,2512,,0.006,0.001,1240.8,0.059,0.064,0.0061,20878.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-03",24,24,2474,,0.006,0.001,1230,0.059,0.063,0.0061,20702.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-04",24,24,2546,,0.006,0.001,1219.8,0.059,0.063,0.0061,20526.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-05",24,24,2487,,0.006,0.001,1195.1,0.059,0.06,0.006,20112.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-06",24,24,2402,,0.006,0.001,1166,0.059,0.063,0.0064,19620,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-07",24,24,2454,,0.006,0.001,1185.7,0.059,0.062,0.0062,19954.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-08",24,24,2515,,0.006,0.001,1208.7,0.059,0.061,0.006,20341.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-09",24,24,2590,,0.006,0.001,1238,0.059,0.063,0.006,20834.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-10",24,24,2674,,0.006,0.001,1268.9,0.059,0.067,0.0063,21353.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-11",24,24,2630,,0.006,0.001,1252.3,0.059,0.064,0.0061,21072,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-12",24,24,2684,,0.006,0.001,1271.4,0.059,0.068,0.0064,21397.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-13",24,24,2534,,0.006,0.001,1214.1,0.059,0.064,0.0063,20429.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-14",24,24,2569,,0.006,0.001,1231.5,0.059,0.062,0.006,20720,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-15",24,24,2751,,0.007,0.001,1307.1,0.059,0.066,0.006,21996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-16",24,24,2779,,0.007,0.001,1319.1,0.059,0.067,0.006,22198.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-17",24,24,2714,,0.007,0.001,1291.4,0.059,0.066,0.006,21732,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-18",24,24,2621,,0.006,0.001,1250.7,0.059,0.066,0.0063,21045.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-19",24,24,2596,,0.006,0.001,1240.8,0.059,0.063,0.006,20878.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-20",24,24,2470,,0.006,0.001,1192.8,0.059,0.061,0.006,20068.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-21",24,24,2482,,0.006,0.001,1195.6,0.059,0.064,0.0063,20121.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-22",24,24,2518,,0.006,0.001,1203.9,0.059,0.065,0.0064,20262.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-23",24,24,2493,,0.006,0.001,1197.3,0.059,0.064,0.0063,20148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-24",24,24,2459,,0.006,0.001,1186.5,0.059,0.06,0.006,19972,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-25",24,24,2476,,0.006,0.001,1193.1,0.059,0.065,0.0065,20077.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-26",24,24,2443,,0.006,0.001,1185.3,0.059,0.062,0.0062,19945.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-27",24,24,2456,,0.006,0.001,1190.4,0.059,0.062,0.0062,20033.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-28",24,24,2586,,0.006,0.001,1239.6,0.059,0.064,0.0061,20860.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-29",24,24,2467,,0.006,0.001,1193.8,0.059,0.062,0.0061,20095.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-30",24,24,2536,,0.006,0.001,1220.2,0.059,0.062,0.006,20535.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-03-31",23,22.23,2215.2,,0.005,0.001,1075.541,0.059,0.059,0.0081,18094.847,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-08",19,18.12,1806.72,,0.004,0.001,878.268,0.0591,0.075,0.015,14780.588,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-09",24,24,2549,,0.006,0.001,1223.4,0.059,0.062,0.006,20591.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-10",24,24,2436,,0.006,0.001,1177,0.059,0.06,0.006,19806.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-11",24,24,2503,,0.006,0.001,1203.4,0.059,0.061,0.006,20247.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-12",24,24,2434,,0.006,0.001,1183.7,0.059,0.061,0.0061,19921.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-13",24,24,2439,,0.006,0.001,1183.2,0.059,0.06,0.006,19912.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-14",24,24,2542,,0.006,0.001,1217.8,0.059,0.063,0.0062,20494.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-15",23,22.23,2228.74,,0.005,0.001,1074.511,0.059,0.06,0.009,18080.683,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-02",1,0.17,0,,0,0.001,1.683,0.059,0.001,0.076,28.322,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-26",16,15.03,1486.99,,0.004,0.001,720.973,0.0591,0.087,0.0247,12133.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-27",24,24,2609,,0.006,0.001,1239.3,0.059,0.065,0.0062,20859.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-28",24,24,2388,,0.006,0.001,1145.6,0.059,0.064,0.0066,19272.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-29",22,21.55,2135.2,,0.005,0.001,1027.7,0.059,0.057,0.007,17290.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-02",15,14.82,1497.96,,0.004,0.001,716.616,0.059,0.086,0.0207,12059.492,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-03",24,24,2721,,0.006,0.001,1271.8,0.059,0.067,0.0063,21406.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-04",24,24,2476,,0.006,0.001,1166.9,0.059,0.064,0.0065,19630.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-05",22,21.05,2122.25,,0.005,0.001,1010.31,0.059,0.057,0.0115,16996.725,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-09",15,14.75,1488.5,,0.004,0.001,714.8,0.059,0.083,0.021,12027.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-10",24,24,2477,,0.006,0.001,1175.3,0.059,0.062,0.0063,19778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-11",24,24,2516,,0.006,0.001,1190.4,0.059,0.063,0.0063,20030.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-12",22,21.72,2198.12,,0.005,0.001,1052.476,0.059,0.057,0.0066,17708.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-15",18,17.78,1671.4,,0.004,0.001,811.244,0.059,0.064,0.0134,13650.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-16",24,24,2418,,0.006,0.001,1156.5,0.059,0.061,0.0063,19456.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-17",24,24,2377,,0.006,0.001,1139.4,0.059,0.061,0.0064,19177.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-18",24,24,2512,,0.006,0.001,1192.5,0.059,0.064,0.0064,20065.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-19",24,24,2644,,0.006,0.001,1241.3,0.059,0.068,0.0065,20884.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-20",24,24,2477,,0.006,0.001,1175.4,0.059,0.063,0.0064,19778.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-21",24,24,2541,,0.006,0.001,1200.8,0.059,0.062,0.0062,20205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-22",24,24,2707,,0.006,0.001,1270,0.059,0.066,0.0062,21372.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-23",24,24,2700,,0.006,0.001,1264.2,0.059,0.067,0.0063,21276.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-24",24,24,2636,,0.006,0.001,1242.7,0.059,0.063,0.006,20910.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-25",24,24,2611,,0.006,0.001,1228.6,0.059,0.065,0.0063,20675.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-26",24,24,2429,,0.006,0.001,1155.2,0.059,0.062,0.0064,19438.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-27",24,24,2519,,0.006,0.001,1188.9,0.059,0.063,0.0063,20004.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-28",24,24,2389,,0.006,0.001,1139.3,0.059,0.06,0.0063,19168.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-29",24,24,2505,,0.006,0.001,1179.7,0.059,0.066,0.0066,19847.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-06-30",24,24,2414,,0.006,0.001,1146.3,0.059,0.062,0.0065,19290.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-01",24,24,2585,,0.006,0.001,1212.9,0.059,0.065,0.0064,20412.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-02",24,24,2501,,0.006,0.001,1183,0.059,0.063,0.0063,19908,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-03",24,24,2538,,0.006,0.001,1198,0.059,0.066,0.0065,20160.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-04",24,24,2384,,0.006,0.001,1137.7,0.059,0.062,0.0065,19142.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-05",24,24,2515,,0.006,0.001,1185.7,0.059,0.065,0.0065,19951.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-06",24,24,2454,,0.006,0.001,1169.2,0.059,0.063,0.0064,19673.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-07",24,24,2467,,0.006,0.001,1174.5,0.059,0.062,0.0063,19768.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-08",24,24,2524,,0.006,0.001,1193.1,0.059,0.063,0.0063,20073.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-09",24,24,2513,,0.006,0.001,1185.6,0.059,0.064,0.0065,19942.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-10",24,24,2444,,0.006,0.001,1156.7,0.059,0.064,0.0066,19464.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-11",24,24,2567,,0.006,0.001,1201.6,0.059,0.066,0.0065,20221.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-12",24,24,2595,,0.006,0.001,1215.8,0.059,0.065,0.0064,20456.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-13",24,24,2592,,0.006,0.001,1213.8,0.059,0.064,0.0063,20421.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-14",24,24,2556,,0.006,0.001,1204.4,0.059,0.064,0.0063,20264.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-15",24,24,2433,,0.006,0.001,1157.2,0.059,0.06,0.0062,19464.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-16",24,24,2445,,0.006,0.001,1161.1,0.059,0.061,0.0063,19533.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-17",24,24,2428,,0.006,0.001,1156.6,0.059,0.06,0.0061,19464.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-18",24,24,2484,,0.006,0.001,1178.2,0.059,0.061,0.0062,19829.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-19",24,24,2463,,0.006,0.001,1169.1,0.059,0.061,0.0062,19673.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-20",24,24,2455,,0.006,0.001,1165.7,0.059,0.061,0.0063,19612.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-21",24,24,2460,,0.006,0.001,1164.6,0.059,0.061,0.0062,19594.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-22",24,24,2591,,0.006,0.001,1219.8,0.059,0.066,0.0065,20525.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-23",24,24,2557,,0.006,0.001,1205.7,0.059,0.062,0.0061,20282.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-24",24,24,2640,,0.006,0.001,1236.7,0.059,0.067,0.0064,20812.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-25",24,24,2639,,0.006,0.001,1235.4,0.059,0.066,0.0064,20786.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-26",24,24,2588,,0.006,0.001,1215,0.059,0.064,0.0063,20447.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-27",24,24,2712,,0.006,0.001,1265.2,0.059,0.068,0.0063,21291.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-28",24,24,2515,,0.006,0.001,1187.7,0.059,0.063,0.0063,19986.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-29",24,24,2551,,0.006,0.001,1196.7,0.059,0.066,0.0065,20134.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-30",24,24,2492,,0.006,0.001,1177.6,0.059,0.063,0.0064,19812.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-07-31",24,24,2476,,0.006,0.001,1171.8,0.059,0.063,0.0064,19716.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-01",24,24,2507,,0.006,0.001,1182.9,0.059,0.065,0.0065,19907.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-02",24,24,2572,,0.006,0.001,1214.8,0.059,0.066,0.0065,20440.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-03",24,24,2663,,0.006,0.001,1251.8,0.059,0.067,0.0064,21061.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-04",24,24,2680,,0.006,0.001,1260.3,0.059,0.07,0.0066,21201.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-05",24,24,2618,,0.006,0.001,1233.5,0.059,0.067,0.0064,20755.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-06",24,24,2559,,0.006,0.001,1207.6,0.059,0.064,0.0063,20318.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-07",24,24,2654,,0.006,0.001,1244.4,0.059,0.068,0.0065,20939.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-08",24,24,2576,,0.006,0.001,1209.9,0.059,0.065,0.0064,20361.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-09",24,24,2687,,0.006,0.001,1257.5,0.059,0.068,0.0065,21157.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-10",24,24,2690,,0.006,0.001,1255.1,0.059,0.068,0.0064,21113.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-11",24,24,2705,,0.006,0.001,1263.9,0.059,0.065,0.0061,21262.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-12",24,24,2590,,0.006,0.001,1216.5,0.059,0.068,0.0066,20467,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-13",24,24,2451,,0.006,0.001,1170.1,0.059,0.065,0.0066,19688.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-14",24,24,2679,,0.006,0.001,1256.3,0.059,0.066,0.0063,21139.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-15",24,24,2754,,0.007,0.001,1288.1,0.059,0.065,0.006,21682.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-16",24,24,2731,,0.006,0.001,1280.6,0.059,0.066,0.0061,21542.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-17",24,24,2854,,0.007,0.001,1332.5,0.059,0.072,0.0065,22416.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-18",24,24,2841,,0.007,0.001,1327,0.059,0.07,0.0063,22329.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-19",24,24,2663,,0.006,0.001,1242.1,0.059,0.069,0.0066,20904.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-20",24,24,2814,,0.007,0.001,1310.9,0.059,0.07,0.0064,22058.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-21",24,24,2707,,0.006,0.001,1265.8,0.059,0.068,0.0064,21298.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-22",24,24,2710,,0.006,0.001,1271.7,0.059,0.069,0.0064,21394.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-23",24,24,2673,,0.006,0.001,1254.3,0.059,0.069,0.0065,21105.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-24",24,24,2763,,0.007,0.001,1296.8,0.059,0.071,0.0065,21822.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-25",24,24,2717,,0.006,0.001,1279.2,0.059,0.071,0.0065,21516.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-26",24,24,2757,,0.007,0.001,1290.4,0.059,0.071,0.0065,21708.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-27",24,24,2605,,0.006,0.001,1225,0.059,0.064,0.0062,20615.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-28",24,24,2721,,0.006,0.001,1272.7,0.059,0.069,0.0065,21420,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-29",24,24,2675,,0.006,0.001,1258.7,0.059,0.066,0.0063,21184,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-30",24,24,2581,,0.006,0.001,1219.6,0.059,0.062,0.006,20528.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-08-31",24,24,2551,,0.006,0.001,1208.9,0.059,0.063,0.0062,20344.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-01",24,24,2646,,0.006,0.001,1247.2,0.059,0.068,0.0065,20988.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-02",24,24,2622,,0.006,0.001,1235.2,0.059,0.064,0.0062,20787,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-03",24,24,2771,,0.007,0.001,1301.6,0.059,0.07,0.0063,21899,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-04",24,24,2718,,0.006,0.001,1274.1,0.059,0.069,0.0065,21443.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-05",24,24,2633,,0.006,0.001,1246.2,0.059,0.067,0.0064,20970.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-06",24,24,2686,,0.006,0.001,1269.9,0.059,0.067,0.0063,21364.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-07",24,24,2805,,0.007,0.001,1314.7,0.059,0.07,0.0063,22118.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-08",24,24,2541,,0.006,0.001,1196.8,0.059,0.067,0.0067,20138.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-09",24,24,2494,,0.006,0.001,1186,0.059,0.063,0.0063,19954.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-10",24,24,2588,,0.006,0.001,1225.3,0.059,0.065,0.0063,20611.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-11",24,24,2651,,0.006,0.001,1253.2,0.059,0.068,0.0065,21084.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-12",24,24,2611,,0.006,0.001,1234.4,0.059,0.068,0.0065,20769.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-13",24,24,2593,,0.006,0.001,1232.2,0.059,0.069,0.0067,20734.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-14",24,24,2581,,0.006,0.001,1224.7,0.059,0.067,0.0065,20603,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-15",24,24,2690,,0.006,0.001,1268.5,0.059,0.069,0.0065,21347.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-16",24,24,2754,,0.007,0.001,1293.6,0.059,0.068,0.0063,21768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-17",24,24,2696,,0.006,0.001,1269,0.059,0.069,0.0065,21356.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-18",24,24,2726,,0.006,0.001,1276.8,0.059,0.067,0.0063,21487.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-19",24,24,2514,,0.006,0.001,1194.6,0.059,0.067,0.0067,20094.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-20",24,24,2683,,0.006,0.001,1264,0.059,0.071,0.0067,21268.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-21",24,24,2691,,0.006,0.001,1267,0.059,0.069,0.0065,21321,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-22",24,24,2450,,0.006,0.001,1166.3,0.059,0.062,0.0064,19621.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-23",24,24,2523,,0.006,0.001,1199.2,0.059,0.064,0.0063,20173.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-24",24,24,2650,,0.006,0.001,1242.5,0.059,0.065,0.0062,20909.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-25",24,24,2602,,0.006,0.001,1227.3,0.059,0.064,0.0063,20646.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-26",24,24,2566,,0.006,0.001,1211.2,0.059,0.064,0.0063,20383.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-27",24,24,2474,,0.006,0.001,1172,0.059,0.066,0.0067,19718.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-28",24,24,2446,,0.006,0.001,1161.1,0.059,0.063,0.0064,19534.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-29",24,24,2518,,0.006,0.001,1193.9,0.059,0.065,0.0065,20086.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-09-30",24,24,2487,,0.006,0.001,1181.9,0.059,0.062,0.0063,19884.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-01",24,24,2552,,0.006,0.001,1217.9,0.06,0.066,0.0065,20339.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-02",24,24,2422,,0.006,0.001,1165.2,0.06,0.064,0.0066,19456.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-03",24,24,2413,,0.006,0.001,1163,0.06,0.064,0.0066,19412.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-04",24,24,2542,,0.006,0.001,1209.7,0.06,0.066,0.0065,20201.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-05",24,24,2588,,0.006,0.001,1225.1,0.06,0.066,0.0065,20456,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-06",24,24,2544,,0.006,0.001,1208.8,0.06,0.065,0.0064,20184.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-07",24,24,2550,,0.006,0.001,1239.4,0.06,0.069,0.0067,20692.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-08",24,24,2468,,0.006,0.001,1207.7,0.06,0.07,0.0069,20166.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-09",24,24,2501,,0.006,0.001,1227.2,0.06,0.068,0.0067,20491,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-10",24,24,2499,,0.006,0.001,1225.9,0.06,0.066,0.0065,20473.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-11",24,24,2436,,0.006,0.001,1198.7,0.06,0.063,0.0063,20017.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-12",24,24,2525,,0.006,0.001,1236.6,0.06,0.065,0.0063,20648.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-13",24,24,2380,,0.006,0.001,1180.2,0.06,0.062,0.0063,19710.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-14",24,24,2456,,0.006,0.001,1207.3,0.06,0.063,0.0062,20157.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-15",24,24,2429,,0.006,0.001,1193.2,0.06,0.061,0.0061,19921,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-16",24,24,2448,,0.006,0.001,1204.2,0.06,0.062,0.0062,20105.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-17",24,24,2392,,0.006,0.001,1177.1,0.06,0.064,0.0065,19658.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-18",24,24,2473,,0.006,0.001,1208.4,0.06,0.064,0.0064,20175.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-19",24,24,2507,,0.006,0.001,1226.7,0.06,0.066,0.0065,20482.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-20",24,24,2517,,0.006,0.001,1231.9,0.06,0.066,0.0065,20570.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-21",24,24,2465,,0.006,0.001,1210.3,0.06,0.068,0.0067,20210.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-22",24,24,2463,,0.006,0.001,1214.7,0.06,0.068,0.0067,20280.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-23",24,24,2523,,0.006,0.001,1237.2,0.06,0.063,0.0061,20657.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-24",24,24,2489,,0.006,0.001,1227.6,0.06,0.068,0.0067,20499.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-25",24,24,2480,,0.006,0.001,1229.6,0.06,0.068,0.0067,20534.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-26",24,24,2619,,0.006,0.001,1280.7,0.06,0.068,0.0063,21385.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-27",24,24,2529,,0.006,0.001,1248.6,0.06,0.064,0.0061,20850.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-28",24,24,2551,,0.006,0.001,1258.5,0.06,0.064,0.0061,21017.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-29",24,24,2489,,0.006,0.001,1227.1,0.06,0.063,0.0062,20490.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-30",24,24,2414,,0.006,0.001,1200.5,0.06,0.063,0.0063,20043.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-10-31",24,24,2389,,0.006,0.001,1188.2,0.06,0.062,0.0063,19842.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-01",24,24,2441,,0.006,0.001,1206.8,0.06,0.061,0.006,20148.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-02",24,24,2513,,0.006,0.001,1236.2,0.06,0.066,0.0063,20640.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-03",24,24,2551,,0.006,0.001,1252.6,0.06,0.066,0.0063,20911.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-04",24,24,2547,,0.006,0.001,1249.4,0.06,0.067,0.0064,20859.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-05",24,24,2530,,0.006,0.001,1245.7,0.06,0.066,0.0063,20797.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-06",24,24,2376,,0.006,0.001,1188.7,0.06,0.067,0.0068,19851.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-07",24,24,2436,,0.006,0.001,1212.5,0.06,0.068,0.0068,20245.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-08",24,24,2460,,0.006,0.001,1218.2,0.06,0.069,0.0068,20341.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-09",24,24,2630,,0.006,0.001,1285.6,0.06,0.069,0.0065,21464.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-10",24,24,2552,,0.006,0.001,1255.9,0.06,0.065,0.0062,20964.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-11",24,24,2450,,0.006,0.001,1215.3,0.06,0.062,0.0061,20289.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-12",24,24,2515,,0.006,0.001,1242.3,0.06,0.063,0.0061,20745.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-13",24,24,2631,,0.006,0.001,1286.5,0.06,0.07,0.0065,21481.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-14",24,24,2541,,0.006,0.001,1249.1,0.06,0.065,0.0063,20850.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-15",24,24,2477,,0.006,0.001,1225.8,0.06,0.062,0.006,20473.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-16",24,24,2556,,0.006,0.001,1255.6,0.06,0.069,0.0066,20964.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-17",24,24,2474,,0.006,0.001,1222.3,0.06,0.065,0.0064,20412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-18",24,24,2412,,0.006,0.001,1201,0.06,0.064,0.0064,20052.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-19",24,24,2524,,0.006,0.001,1250.8,0.06,0.068,0.0065,20885.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-20",24,24,2543,,0.006,0.001,1254.5,0.06,0.066,0.0063,20946.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-21",24,24,2550,,0.006,0.001,1255.7,0.06,0.063,0.006,20973.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-22",24,24,2458,,0.006,0.001,1219.5,0.06,0.064,0.0063,20368.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-23",24,24,2414,,0.006,0.001,1203.6,0.06,0.065,0.0065,20096.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-24",24,24,2435,,0.006,0.001,1217.3,0.06,0.062,0.0061,20324.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-25",16,15.15,1430.65,,0.004,0.001,727.375,0.06,0.068,0.0223,12142.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-27",1,0.17,0,,0,0.001,1.7,0.06,0.001,0.074,28.322,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-14",4,3.38,74.22,,0,0.001,92.336,0.0598,0.096,0.1213,1551.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-16",16,15.35,1293,,0.004,0.001,696.51,0.0598,0.131,0.0353,11694.825,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-17",24,24,2401,,0.006,0.001,1200.7,0.0599,0.065,0.0064,20166.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-18",24,24,2545,,0.006,0.001,1262.6,0.0598,0.069,0.0065,21210,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-19",24,24,2492,,0.006,0.001,1241.4,0.0598,0.066,0.0063,20850.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-20",24,24,2566,,0.006,0.001,1274.8,0.0598,0.067,0.0062,21411.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-21",24,24,2537,,0.006,0.001,1260.2,0.0598,0.066,0.0062,21166.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-22",24,24,2510,,0.006,0.001,1250.3,0.0598,0.064,0.0061,20999.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-23",24,24,2532,,0.006,0.001,1256,0.0599,0.064,0.0061,21096,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-24",24,24,2488,,0.006,0.001,1239.3,0.0599,0.066,0.0064,20815.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-25",24,24,2434,,0.006,0.001,1213.8,0.0599,0.071,0.0069,20385.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-26",24,24,2412,,0.006,0.001,1205.1,0.06,0.066,0.0065,20236.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-27",24,24,2416,,0.006,0.001,1207.4,0.0598,0.067,0.0066,20280.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-28",24,24,2392,,0.006,0.001,1199.7,0.0599,0.063,0.0063,20149.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-29",24,24,2417,,0.006,0.001,1209,0.0598,0.061,0.006,20306.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-30",24,24,2408,,0.006,0.001,1207.7,0.0597,0.061,0.006,20289.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"1",,"2020-12-31",24,24,2318,,0.006,0.001,1173,0.0598,0.062,0.0063,19701.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-01",24,24,2408,,0.006,0.001,1170.8,0.059,0.059,0.006,19697.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-02",24,24,2410,,0.006,0.001,1172.4,0.059,0.06,0.0061,19732.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-03",24,24,2549,,0.006,0.001,1231.2,0.059,0.062,0.006,20717.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-04",24,24,2429,,0.006,0.001,1183.6,0.059,0.06,0.006,19917.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-05",24,24,2434,,0.006,0.001,1188,0.059,0.06,0.006,19987.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-06",24,24,2563,,0.006,0.001,1238.2,0.059,0.065,0.0062,20840.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-07",24,24,2550,,0.006,0.001,1235.3,0.059,0.067,0.0064,20787.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-08",24,24,2545,,0.006,0.001,1230.2,0.059,0.064,0.0062,20699.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-09",24,24,2611,,0.006,0.001,1250.5,0.059,0.067,0.0064,21042.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-10",24,24,2607,,0.006,0.001,1252.9,0.059,0.067,0.0063,21078.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-11",24,24,2454,,0.006,0.001,1191.7,0.059,0.061,0.0061,20058.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-12",24,24,2529,,0.006,0.001,1220.7,0.059,0.062,0.006,20541.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-13",24,24,2553,,0.006,0.001,1231.1,0.059,0.063,0.0061,20717.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-14",24,24,2544,,0.006,0.001,1226.5,0.059,0.062,0.006,20637.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-15",24,24,2656,,0.006,0.001,1271.9,0.059,0.065,0.0061,21403.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-16",24,24,2716,,0.007,0.001,1293.3,0.059,0.071,0.0065,21764,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-17",24,24,2567,,0.006,0.001,1239.8,0.059,0.065,0.0063,20866.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-18",24,24,2528,,0.006,0.001,1220.3,0.059,0.062,0.006,20532.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-19",24,24,2636,,0.006,0.001,1270.1,0.059,0.065,0.0061,21376.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-20",23,22.6,2454.8,,0.006,0.001,1182.1,0.059,0.064,0.0067,19889.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-21",15,14.88,1491.88,,0.004,0.001,729.68,0.059,0.063,0.0151,12281.216,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-22",24,24,2492,,0.006,0.001,1206.5,0.059,0.061,0.006,20295.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-23",24,24,2374,,0.006,0.001,1166.9,0.059,0.059,0.006,19626.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-24",24,24,2518,,0.006,0.001,1246.4,0.059,0.063,0.006,20981.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-25",24,24,2342,,0.006,0.001,1180.1,0.059,0.06,0.006,19855.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-26",24,24,2499,,0.006,0.001,1234.9,0.059,0.064,0.0061,20778.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-27",24,24,2481,,0.006,0.001,1228.1,0.059,0.065,0.0063,20673.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-28",24,24,2498,,0.006,0.001,1229.4,0.059,0.064,0.0062,20690.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-29",1,0.08,1.36,,0,0.001,0.624,0.059,0,0.081,10.552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-03",21,20.22,1803.22,,0.005,0.001,949.65,0.059,0.173,0.0325,15982.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-04",24,24,2538,,0.006,0.001,1239.7,0.059,0.066,0.0063,20855.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-05",24,24,2523,,0.006,0.001,1218.9,0.059,0.063,0.0061,20512.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-06",24,24,2836,,0.007,0.001,1376,0.059,0.074,0.0064,23157.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-07",24,24,2548,,0.006,0.001,1258.9,0.059,0.064,0.006,21181,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-08",24,24,2445,,0.006,0.001,1220.9,0.059,0.062,0.0061,20539.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-09",24,24,2353,,0.006,0.001,1179.1,0.059,0.066,0.0067,19836.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-10",24,24,2537,,0.006,0.001,1253.2,0.059,0.072,0.0068,21083.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-11",24,24,2393,,0.006,0.001,1203.5,0.059,0.061,0.006,20249.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-12",24,24,2567,,0.006,0.001,1229.4,0.059,0.066,0.0063,20679.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-13",24,24,2535,,0.006,0.001,1215.2,0.059,0.062,0.0061,20442.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-14",24,24,2572,,0.006,0.001,1231.4,0.059,0.063,0.006,20723.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-15",24,24,2512,,0.006,0.001,1209,0.059,0.063,0.0062,20346.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-16",24,24,2477,,0.006,0.001,1231,0.059,0.064,0.0062,20715.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-17",24,24,2379,,0.006,0.001,1193,0.059,0.067,0.0066,20082.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-18",24,24,2477,,0.006,0.001,1233.9,0.059,0.067,0.0065,20759.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-19",24,24,2553,,0.006,0.001,1227.9,0.059,0.067,0.0065,20662.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-20",24,24,2625,,0.006,0.001,1255.6,0.059,0.068,0.0064,21128,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-21",24,24,2705,,0.006,0.001,1279.7,0.059,0.067,0.0063,21532.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-22",24,24,2496,,0.006,0.001,1195.2,0.059,0.065,0.0065,20108.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-23",24,24,2516,,0.006,0.001,1243.1,0.059,0.069,0.0065,20917,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-24",24,24,2656,,0.007,0.001,1297,0.059,0.07,0.0064,21822,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-25",24,24,2666,,0.007,0.001,1308.3,0.059,0.071,0.0065,22015.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-26",24,24,2589,,0.006,0.001,1236,0.059,0.064,0.0061,20794.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-27",24,24,2539,,0.006,0.001,1211.6,0.059,0.063,0.0062,20390.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-28",23,22.55,2245.55,,0.006,0.001,1090.05,0.059,0.059,0.0068,18341.53,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-03",4,3.12,216.6,,0.001,0.001,120.236,0.059,0.047,0.0515,2022.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-04",24,24,2542,,0.006,0.001,1219.2,0.059,0.068,0.0066,20517.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-05",24,24,2481,,0.006,0.001,1194,0.059,0.061,0.006,20095.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-06",24,24,2396,,0.006,0.001,1163.4,0.059,0.06,0.0061,19576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-07",24,24,2442,,0.006,0.001,1182.5,0.059,0.06,0.006,19901.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-08",24,24,2510,,0.006,0.001,1206.5,0.059,0.062,0.0061,20306.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-09",24,24,2583,,0.006,0.001,1235.4,0.059,0.068,0.0065,20790.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-10",24,24,2665,,0.006,0.001,1268.4,0.059,0.069,0.0064,21344.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-11",24,24,2621,,0.006,0.001,1250.3,0.059,0.063,0.006,21036.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-12",24,24,2672,,0.006,0.001,1268.3,0.059,0.067,0.0063,21344.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-13",24,24,2532,,0.006,0.001,1213.2,0.059,0.071,0.0069,20412,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-14",24,24,2557,,0.006,0.001,1228.5,0.059,0.067,0.0065,20667.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-15",24,24,2748,,0.007,0.001,1307.1,0.059,0.067,0.0061,21996,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-16",24,24,2770,,0.007,0.001,1315.6,0.059,0.066,0.006,22136.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-17",24,24,2707,,0.007,0.001,1288.6,0.059,0.065,0.006,21688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-18",24,24,2613,,0.006,0.001,1248,0.059,0.064,0.0061,21001.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-19",24,24,2587,,0.006,0.001,1239.3,0.059,0.069,0.0066,20852,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-20",24,24,2461,,0.006,0.001,1190.5,0.059,0.063,0.0063,20033.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-21",24,24,2473,,0.006,0.001,1190.4,0.059,0.06,0.006,20033.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-22",24,24,2506,,0.006,0.001,1198.3,0.059,0.061,0.006,20165.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-23",24,24,2489,,0.006,0.001,1195.1,0.059,0.061,0.0061,20112.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-24",24,24,2449,,0.006,0.001,1183.4,0.059,0.06,0.006,19919.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-25",24,24,2469,,0.006,0.001,1191.5,0.059,0.06,0.006,20051.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-26",24,24,2434,,0.006,0.001,1180.9,0.059,0.06,0.006,19875.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-27",24,24,2448,,0.006,0.001,1186.7,0.059,0.062,0.0062,19972,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-28",24,24,2575,,0.006,0.001,1237.1,0.059,0.063,0.006,20816.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-29",24,24,2461,,0.006,0.001,1191.3,0.059,0.061,0.0061,20051.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-30",24,24,2530,,0.006,0.001,1217.1,0.059,0.064,0.0062,20482.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-03-31",24,24,2405,,0.006,0.001,1172.3,0.059,0.06,0.006,19725.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-01",24,24,1557,,0.004,0.001,858.6,0.059,0.048,0.0067,14454.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-02",24,24,1496,,0.004,0.001,842.4,0.059,0.048,0.0068,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-03",24,24,1529,,0.004,0.001,842.4,0.059,0.045,0.0063,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-04",24,24,1575,,0.004,0.001,842.4,0.059,0.044,0.0063,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-05",24,24,1552,,0.004,0.001,850.5,0.059,0.044,0.0062,14318.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-06",24,24,1575,,0.004,0.001,866.7,0.059,0.049,0.0067,14591.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-07",24,24,1514,,0.004,0.001,842.4,0.059,0.045,0.0064,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-08",24,24,1534,,0.004,0.001,850.5,0.059,0.046,0.0064,14318.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-09",24,24,1522,,0.004,0.001,842.4,0.059,0.043,0.0061,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-10",24,24,1435,,0.004,0.001,842.4,0.059,0.043,0.006,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-11",24,24,1484,,0.004,0.001,842.4,0.059,0.043,0.006,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-12",24,24,1433,,0.004,0.001,842.4,0.059,0.043,0.006,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-13",24,24,1436,,0.004,0.001,842.4,0.059,0.045,0.0064,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-14",24,24,1510,,0.004,0.001,842.4,0.059,0.048,0.0068,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-15",24,24,1431,,0.004,0.001,842.4,0.059,0.044,0.0063,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-16",24,24,1533,,0.004,0.001,850.5,0.059,0.046,0.0065,14318.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-17",24,24,1464,,0.004,0.001,842.4,0.059,0.045,0.0063,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-18",24,24,1497,,0.004,0.001,842.4,0.059,0.044,0.0062,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-19",24,24,1487,,0.004,0.001,850.5,0.059,0.044,0.0061,14318.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-20",24,24,1546,,0.004,0.001,874.8,0.059,0.047,0.0064,14728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-21",24,24,1522,,0.004,0.001,842.4,0.059,0.046,0.0065,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-22",24,24,1601,,0.004,0.001,866.7,0.059,0.048,0.0065,14591.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-23",24,24,1429,,0.004,0.001,842.4,0.059,0.044,0.0063,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-24",24,24,1472,,0.004,0.001,842.4,0.059,0.046,0.0065,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-25",24,24,1423,,0.004,0.001,842.4,0.059,0.045,0.0064,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-26",24,24,1484,,0.004,0.001,842.4,0.059,0.048,0.0067,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-27",24,24,1448,,0.004,0.001,842.4,0.059,0.046,0.0065,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-28",24,24,1549,,0.004,0.001,850.5,0.059,0.047,0.0065,14318.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-29",24,24,1448,,0.004,0.001,858.6,0.059,0.049,0.0067,14454.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-04-30",24,24,1470,,0.004,0.001,842.4,0.059,0.047,0.0067,14181.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-01",18,17.38,986.92,,0.003,0.001,604.586,0.059,0.036,0.0078,10177.424,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-03",1,0.13,0,,0,0.001,1.287,0.059,0.001,0.07,21.658,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-24",2,0.24,0.17,,0,0.001,2.993,0.059,0.001,0.058,50.331,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-25",16,15.27,1340,,0.004,0.001,703.11,0.0591,0.109,0.0274,11825.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-26",24,24,2584,,0.006,0.001,1244.6,0.059,0.069,0.0066,20946.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-27",24,24,2623,,0.006,0.001,1242.8,0.059,0.068,0.0065,20912,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-28",24,24,2371,,0.006,0.001,1134.9,0.059,0.064,0.0068,19088.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-29",24,24,2379,,0.006,0.001,1145.6,0.059,0.063,0.0066,19272.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-30",24,24,2518,,0.006,0.001,1232.7,0.059,0.067,0.0064,20745.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-05-31",24,24,2505,,0.006,0.001,1227.4,0.059,0.065,0.0063,20648.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-01",24,24,2687,,0.007,0.001,1289.8,0.059,0.071,0.0065,21702.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-02",24,24,2515,,0.006,0.001,1203.8,0.059,0.067,0.0066,20257.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-03",24,24,2734,,0.006,0.001,1274.5,0.059,0.067,0.0063,21441.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-04",24,24,2462,,0.006,0.001,1157.7,0.059,0.064,0.0066,19473.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-05",24,24,2433,,0.006,0.001,1157.1,0.059,0.065,0.0066,19465,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-06",24,24,2418,,0.006,0.001,1190.1,0.059,0.069,0.0069,20022.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-07",24,24,2421,,0.006,0.001,1194.2,0.059,0.068,0.0067,20091.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-08",24,24,2456,,0.006,0.001,1204,0.059,0.071,0.007,20265.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-09",24,24,2449,,0.006,0.001,1185.6,0.059,0.065,0.0065,19952.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-10",24,24,2465,,0.006,0.001,1164.7,0.059,0.064,0.0065,19595.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-11",24,24,2503,,0.006,0.001,1178.9,0.059,0.064,0.0065,19830.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-12",24,24,2423,,0.006,0.001,1156.5,0.059,0.064,0.0066,19456.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-13",24,24,2340,,0.006,0.001,1154.2,0.059,0.061,0.0063,19421,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-14",24,24,2417,,0.006,0.001,1185.7,0.059,0.062,0.0062,19943.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-15",24,24,2361,,0.006,0.001,1142.2,0.059,0.063,0.0065,19221,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-16",24,24,2401,,0.006,0.001,1145.3,0.059,0.062,0.0064,19264.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-17",24,24,2364,,0.006,0.001,1129.3,0.059,0.062,0.0065,19003.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-18",24,24,2499,,0.006,0.001,1181.9,0.059,0.066,0.0066,19883.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-19",24,24,2627,,0.006,0.001,1229.3,0.059,0.069,0.0067,20684.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-20",24,24,2461,,0.006,0.001,1162.5,0.059,0.065,0.0067,19560.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-21",24,24,2529,,0.006,0.001,1191.4,0.059,0.064,0.0064,20047.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-22",24,24,2701,,0.006,0.001,1264,0.059,0.066,0.0062,21267.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-23",24,24,2585,,0.006,0.001,1215.9,0.059,0.066,0.0064,20457.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-24",24,24,2571,,0.006,0.001,1212.1,0.059,0.065,0.0063,20396.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-25",24,24,2596,,0.006,0.001,1217.7,0.059,0.065,0.0064,20492.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-26",24,24,2414,,0.006,0.001,1145.8,0.059,0.062,0.0064,19281.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-27",24,24,2505,,0.006,0.001,1178.7,0.059,0.063,0.0064,19839.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-28",24,24,2374,,0.006,0.001,1128.7,0.059,0.061,0.0064,18986,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-29",24,24,2486,,0.006,0.001,1167.8,0.059,0.067,0.0068,19647.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-06-30",24,24,2399,,0.006,0.001,1135.6,0.059,0.062,0.0065,19107.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-01",24,24,2564,,0.006,0.001,1201.6,0.059,0.066,0.0065,20221.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-02",24,24,2486,,0.006,0.001,1171.8,0.059,0.065,0.0066,19716.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-03",24,24,2518,,0.006,0.001,1187.6,0.059,0.068,0.0068,19986.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-04",24,24,2374,,0.006,0.001,1126.2,0.059,0.062,0.0066,18951,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-05",24,24,2501,,0.006,0.001,1176,0.059,0.066,0.0067,19786.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-06",24,24,2439,,0.006,0.001,1157.3,0.059,0.065,0.0067,19473,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-07",24,24,2451,,0.006,0.001,1163.8,0.059,0.063,0.0065,19586.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-08",24,24,2488,,0.006,0.001,1172.9,0.059,0.064,0.0065,19734,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-09",24,24,2497,,0.006,0.001,1174.8,0.059,0.066,0.0066,19760.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-10",24,24,2430,,0.006,0.001,1145,0.059,0.067,0.0069,19264.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-11",24,24,2547,,0.006,0.001,1189.3,0.059,0.067,0.0067,20012.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-12",24,24,2587,,0.006,0.001,1207.4,0.059,0.066,0.0065,20316.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-13",24,24,2577,,0.006,0.001,1201,0.059,0.067,0.0066,20212.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-14",24,24,2536,,0.006,0.001,1191.9,0.059,0.064,0.0064,20055.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-15",24,24,2420,,0.006,0.001,1143.7,0.059,0.061,0.0063,19246.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-16",24,24,2428,,0.006,0.001,1147.8,0.059,0.063,0.0065,19316.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-17",24,24,2416,,0.006,0.001,1145.5,0.059,0.062,0.0064,19272.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-18",24,24,2467,,0.006,0.001,1165.6,0.059,0.063,0.0064,19612.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-19",24,24,2434,,0.006,0.001,1153,0.059,0.062,0.0064,19403.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-20",24,24,2432,,0.006,0.001,1151.1,0.059,0.061,0.0063,19368.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-21",24,24,2434,,0.006,0.001,1150.9,0.059,0.061,0.0063,19368.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-22",24,24,2522,,0.006,0.001,1187.8,0.059,0.063,0.0063,19986.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-23",24,24,2539,,0.006,0.001,1192.8,0.059,0.062,0.0062,20073.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-24",24,24,2640,,0.006,0.001,1231.4,0.059,0.067,0.0065,20725.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-25",24,24,2626,,0.006,0.001,1225,0.059,0.067,0.0065,20612.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-26",24,24,2570,,0.006,0.001,1201.6,0.059,0.064,0.0064,20221.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-27",24,24,2713,,0.006,0.001,1262.6,0.059,0.07,0.0066,21247.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-28",24,24,2499,,0.006,0.001,1176.5,0.059,0.062,0.0063,19794.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-29",24,24,2542,,0.006,0.001,1187.5,0.059,0.067,0.0067,19977.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-30",24,24,2480,,0.006,0.001,1166.3,0.059,0.065,0.0066,19620.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-07-31",24,24,2444,,0.006,0.001,1155.5,0.059,0.064,0.0065,19438.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-01",24,24,2491,,0.006,0.001,1172.6,0.059,0.065,0.0066,19732.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-02",24,24,2538,,0.006,0.001,1196.3,0.059,0.066,0.0065,20126.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-03",24,24,2616,,0.006,0.001,1230.5,0.059,0.068,0.0065,20703,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-04",24,24,2668,,0.006,0.001,1250.5,0.059,0.067,0.0064,21044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-05",24,24,2593,,0.006,0.001,1219,0.059,0.066,0.0064,20510.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-06",24,24,2542,,0.006,0.001,1194.3,0.059,0.065,0.0065,20099.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-07",24,24,2636,,0.006,0.001,1232.7,0.059,0.067,0.0065,20738.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-08",24,24,2558,,0.006,0.001,1198.6,0.059,0.065,0.0065,20169.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-09",24,24,2676,,0.006,0.001,1246.7,0.059,0.069,0.0065,20974.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-10",24,24,2604,,0.006,0.001,1218.7,0.059,0.068,0.0067,20502.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-11",24,24,2451,,0.006,0.001,1164.9,0.059,0.063,0.0065,19601.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-12",24,24,2559,,0.006,0.001,1201.9,0.059,0.065,0.0065,20222.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-13",24,24,2634,,0.006,0.001,1230.4,0.059,0.066,0.0063,20694.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-14",24,24,2678,,0.006,0.001,1253.6,0.059,0.069,0.0065,21088.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-15",24,24,2713,,0.006,0.001,1269.7,0.059,0.066,0.0062,21367.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-16",24,24,2756,,0.007,0.001,1289.3,0.059,0.068,0.0063,21691,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-17",24,24,2799,,0.007,0.001,1305.5,0.059,0.073,0.0066,21970.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-18",24,24,2793,,0.007,0.001,1305.2,0.059,0.07,0.0064,21962,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-19",24,24,2451,,0.006,0.001,1162.2,0.059,0.065,0.0066,19557.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-20",24,24,2823,,0.007,0.001,1311,0.059,0.073,0.0066,22066.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-21",24,24,2702,,0.006,0.001,1260.5,0.059,0.068,0.0064,21210,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-22",24,24,2704,,0.006,0.001,1267.2,0.059,0.067,0.0063,21323.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-23",24,24,2655,,0.006,0.001,1243.2,0.059,0.066,0.0063,20921.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-24",24,24,2759,,0.007,0.001,1291,0.059,0.068,0.0063,21725.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-25",24,24,2727,,0.006,0.001,1277.9,0.059,0.067,0.0062,21498.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-26",24,24,2766,,0.007,0.001,1289.6,0.059,0.069,0.0064,21699.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-27",24,24,2615,,0.006,0.001,1228.3,0.059,0.065,0.0063,20668.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-28",24,24,2708,,0.006,0.001,1266.4,0.059,0.069,0.0065,21306.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-29",24,24,2685,,0.006,0.001,1259.1,0.059,0.067,0.0063,21184.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-30",24,24,2549,,0.006,0.001,1201.6,0.059,0.062,0.0061,20222.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-08-31",24,24,2511,,0.006,0.001,1189,0.059,0.062,0.0062,20003.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-01",24,24,2638,,0.006,0.001,1241.2,0.059,0.068,0.0065,20882.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-02",24,24,2526,,0.006,0.001,1193.8,0.059,0.064,0.0064,20085.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-03",24,24,2750,,0.007,0.001,1288,0.059,0.067,0.0062,21671.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-04",24,24,2737,,0.006,0.001,1278.1,0.059,0.07,0.0065,21505,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-05",24,24,2656,,0.006,0.001,1252.2,0.059,0.067,0.0064,21067.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-06",24,24,2679,,0.006,0.001,1263.1,0.059,0.067,0.0063,21251.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-07",24,24,2799,,0.007,0.001,1307.5,0.059,0.068,0.0062,21995.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-08",24,24,2532,,0.006,0.001,1188.2,0.059,0.068,0.0068,19989.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-09",24,24,2481,,0.006,0.001,1174.7,0.059,0.069,0.007,19762,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-10",24,24,2572,,0.006,0.001,1213.4,0.059,0.062,0.0061,20410.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-11",24,24,2667,,0.006,0.001,1254.6,0.059,0.065,0.0061,21110.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-12",24,24,2584,,0.006,0.001,1219.3,0.059,0.063,0.0062,20515,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-13",24,24,2608,,0.006,0.001,1233.6,0.059,0.064,0.0062,20752.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-14",24,24,2532,,0.006,0.001,1201.9,0.059,0.062,0.0062,20225.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-15",24,24,2649,,0.006,0.001,1250,0.059,0.066,0.0063,21031.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-16",24,24,2738,,0.006,0.001,1281.6,0.059,0.067,0.0062,21566.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-17",24,24,2685,,0.006,0.001,1261.6,0.059,0.065,0.0061,21233.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-18",24,24,2720,,0.006,0.001,1271.5,0.059,0.065,0.0061,21399.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-19",24,24,2498,,0.006,0.001,1183.6,0.059,0.06,0.006,19919.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-20",24,24,2682,,0.006,0.001,1258.3,0.059,0.066,0.0062,21172.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-21",24,24,2676,,0.006,0.001,1257.8,0.059,0.066,0.0063,21163.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-22",24,24,2432,,0.006,0.001,1153.8,0.059,0.064,0.0065,19411.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-23",24,24,2508,,0.006,0.001,1187.6,0.059,0.063,0.0063,19980.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-24",24,24,2613,,0.006,0.001,1223.8,0.059,0.064,0.0063,20594.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-25",24,24,2591,,0.006,0.001,1218.5,0.059,0.064,0.0062,20497.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-26",24,24,2500,,0.006,0.001,1181.4,0.059,0.061,0.0062,19884.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-27",24,24,2459,,0.006,0.001,1161.5,0.059,0.059,0.006,19542.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-28",24,24,2425,,0.006,0.001,1149.2,0.059,0.063,0.0065,19332.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-29",24,24,2467,,0.006,0.001,1169.7,0.059,0.063,0.0064,19683.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-09-30",24,24,2405,,0.006,0.001,1145.9,0.059,0.063,0.0065,19280.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-01",24,24,2534,,0.006,0.001,1206.9,0.06,0.062,0.0062,20155.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-02",24,24,2408,,0.006,0.001,1154.8,0.06,0.059,0.0061,19281.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-03",24,24,2396,,0.006,0.001,1150.4,0.06,0.061,0.0064,19211.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-04",24,24,2530,,0.006,0.001,1201.1,0.06,0.064,0.0064,20052.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-05",24,24,2577,,0.006,0.001,1216.8,0.06,0.063,0.0062,20315.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-06",22,21.05,2190.45,,0.005,0.001,1034.155,0.06,0.058,0.0114,17266.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-16",2,0.15,1,,0,0.001,1.525,0.06,0.001,0.055,25.43,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-21",1,0.17,1.02,,0,0.001,1.683,0.059,0.001,0.073,28.322,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Energy Center",56078,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-22",16,15.46,358.14,,0.001,0.001,256.43,0.0592,0.02,0.0105,4316.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-07",4,3.15,58.4,,0,0.001,45.195,0.0593,0.012,0.0405,760.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-19",1,0.15,0,,0,0.001,0.855,0.06,0.002,0.255,14.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-20",4,2.99,133.74,,0,0.001,78.56,0.059,0.007,0.051,1322.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-25",3,1.55,45.2,,0,0.001,29.28,0.0597,0.005,0.043,491.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-26",8,6.55,132.8,,0.001,0.001,100.92,0.0596,0.01,0.0344,1698.089,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-02",8,7.22,170.7,,0.001,0.001,121.842,0.0595,0.011,0.0144,2050.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-04",5,4,106.74,,0,0.001,72.688,0.0592,0.006,0.018,1223.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-10",12,10.58,241.9,,0.001,0.001,173.466,0.0595,0.014,0.0167,2917.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-11",9,8.33,285.62,,0.001,0.001,181.158,0.0594,0.018,0.0138,3047.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-26",6,4.73,149.14,,0,0.001,96.765,0.0593,0.009,0.0188,1628.247,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-01",7,6,146.2,,0.001,0.001,102.115,0.059,0.008,0.0243,1721.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-02",1,0.2,0,,0,0.001,1.12,0.06,0.002,0.247,18.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-08",10,8.93,191.49,,0.001,0.001,141.311,0.0597,0.011,0.0131,2374.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-27",8,6.33,229.25,,0.001,0.001,142.464,0.0591,0.012,0.0296,2398.227,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-28",9,8,201.2,,0.001,0.001,138.9,0.0593,0.012,0.0261,2338.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-29",7,6.03,174.4,,0.001,0.001,114.303,0.0591,0.012,0.0154,1924.113,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-04",8,6.2,167.36,,0.001,0.001,111.771,0.0595,0.012,0.0433,1880.087,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-09",4,2.94,91.46,,0,0.001,58.642,0.0593,0.007,0.018,986.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-14",12,11.24,399.12,,0.001,0.001,243.256,0.0592,0.02,0.0126,4095.179,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-15",9,6.71,238.53,,0.001,0.001,145.58,0.0591,0.014,0.0344,2453.053,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-16",24,23.93,943.04,,0.003,0.001,563.319,0.0593,0.039,0.0083,9478.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-17",13,12.3,357.3,,0.001,0.001,232.49,0.0595,0.017,0.0094,3910.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-18",6,5.81,132.51,,0,0.001,94.417,0.0593,0.009,0.0117,1588.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-23",8,7.27,184.78,,0.001,0.001,125.43,0.0595,0.011,0.0153,2108.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-24",11,10.14,254.68,,0.001,0.001,174.113,0.0593,0.013,0.0209,2932.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-26",5,4.7,96.2,,0,0.001,71.389,0.0592,0.008,0.0142,1201.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-01",4,3.08,56.73,,0,0.001,43.944,0.0595,0.005,0.0188,738.377,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-06",10,9.38,308.32,,0.001,0.001,193.836,0.0592,0.016,0.0121,3262.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-07",10,9.22,290.64,,0.001,0.001,185.098,0.0592,0.016,0.013,3113.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-08",17,16.11,735.17,,0.002,0.001,424.427,0.0592,0.031,0.0109,7142.589,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-09",7,5.53,245.94,,0.001,0.001,143.607,0.0591,0.014,0.0271,2417.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-11",3,2.84,73.48,,0,0.001,49.759,0.059,0.01,0.026,838.351,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-17",3,1.6,38.15,,0,0.001,26.695,0.0593,0.004,0.044,448.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-22",4,2.72,58.78,,0,0.001,42.718,0.0598,0.006,0.032,717.446,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-03",4,2.58,50.2,,0,0.001,37.898,0.059,0.006,0.0673,638.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-05",9,8.67,197.39,,0.001,0.001,137.644,0.0592,0.015,0.0137,2316.171,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-14",3,2.22,38.64,,0,0.001,30.396,0.059,0.006,0.0303,511.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-20",10,9.84,190.25,,0.001,0.001,142.922,0.0595,0.015,0.0125,2403.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-09",4,2.21,59.16,,0,0.001,38.99,0.0598,0.007,0.0805,654.574,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-13",1,0.1,0,,0,0.001,0.56,0.059,0.001,0.174,9.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-19",1,0.12,0,,0,0.001,0.684,0.059,0.001,0.174,11.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-28",16,16,301,,0.001,0.001,234.3,0.0593,0.021,0.0106,3942.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-29",17,16.1,341.1,,0.001,0.001,252.46,0.0593,0.019,0.0185,4244.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-01",4,3.43,62.28,,0,0.001,49.098,0.0595,0.006,0.0168,826.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-13",3,1.4,23.75,,0,0.001,19.03,0.0593,0.005,0.0803,320.185,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-20",2,1.97,45.4,,0,0.001,30.871,0.0595,0.006,0.026,519.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-21",11,10.08,367,,0.001,0.001,222.132,0.059,0.018,0.0277,3739.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-22",8,7.05,188,,0.001,0.001,123.89,0.0594,0.013,0.0435,2084.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-23",21,20.37,553.92,,0.002,0.001,365.136,0.0593,0.029,0.0103,6145.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-28",2,0.12,2.13,,0,0.001,1.654,0.0595,0.002,0.1855,27.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-29",5,2.28,66.99,,0,0.001,43.912,0.0596,0.012,0.143,737.549,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-07",5,3.37,81.19,,0,0.001,55.085,0.0594,0.027,0.068,926.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-18",3,1.14,41.62,,0,0.0007,25.47,0.0597,0.009,0.1603,428.636,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-19",1,0.13,0,,0,0.001,0.728,0.06,0.002,0.279,12.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-20",3,1.5,60.5,,0,0.001,36.68,0.059,0.004,0.0287,617.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-04",8,7.37,213.47,,0.001,0.001,136.286,0.059,0.015,0.0155,2294.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-04",5,3.63,168.2,,0.001,0.001,99.862,0.0594,0.01,0.052,1679.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-05",2,1.35,26.4,,0,0.001,19.08,0.059,0.004,0.023,322.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-23",7,5.3,111.92,,0,0.001,79.732,0.0596,0.008,0.0421,1341.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-26",9,8,268.97,,0.001,0.001,168.312,0.0591,0.014,0.0144,2833.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-27",7,5.88,135.04,,0,0.001,92.169,0.0593,0.008,0.0149,1551.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-01",5,3.82,88.28,,0,0.001,60.293,0.0594,0.009,0.0612,1014.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-24",6,4.17,92.8,,0,0.001,63.207,0.0593,0.009,0.0752,1064.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-27",9,7.28,254.13,,0.001,0.001,157.237,0.0592,0.015,0.0442,2646.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-07-31",3,1.43,53.05,,0,0.001,32.446,0.0597,0.007,0.0773,546.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-09",4,2.93,94.24,,0,0.001,59.548,0.059,0.008,0.0228,1001.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-13",12,10.81,365.44,,0.001,0.001,224.307,0.0591,0.021,0.0315,3777.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-15",13,13,445,,0.001,0.001,271.2,0.0593,0.024,0.0105,4563.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-16",24,24,1158,,0.003,0.001,671.5,0.0592,0.048,0.0085,11296.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-17",23,22.87,810.84,,0.002,0.001,492.513,0.0592,0.037,0.009,8289.941,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-18",17,16.5,605.4,,0.002,0.001,367.42,0.0591,0.029,0.0113,6184.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-25",13,12.35,440.9,,0.001,0.001,267.105,0.0594,0.021,0.0115,4492.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-02",3,2.12,47.8,,0,0.001,32.448,0.059,0.007,0.034,546.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-06",7,5.6,143.45,,0,0.001,95.515,0.0591,0.012,0.0454,1608.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-08",11,9.93,288.77,,0.001,0.001,183.986,0.0592,0.017,0.0201,3096.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-09",8,6.87,305.12,,0.001,0.001,179.332,0.0591,0.018,0.0474,3017.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-10",15,14.78,627.74,,0.002,0.001,371.951,0.0593,0.032,0.0124,6259.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-11",5,3.53,109.09,,0,0.001,68.698,0.0596,0.01,0.0382,1155.499,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-17",17,16.65,652,,0.002,0.001,389.625,0.0591,0.032,0.0105,6559.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-19",4,3.41,67.38,,0,0.001,48.635,0.0593,0.009,0.0258,819.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-21",9,7.63,272.08,,0.001,0.001,166.032,0.0592,0.015,0.0203,2794.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-09",7,3.63,88.31,,0,0.001,59.074,0.0591,0.018,0.1321,995.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-13",1,0.1,0,,0,0.001,0.54,0.059,0.001,0.308,9.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-24",1,0.15,0,,0,0.001,0.855,0.06,0.002,0.215,14.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-01",2,0.5,7.7,,0,0.001,6.02,0.0595,0.004,0.077,101.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Ripon Generation Station",56135,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-14",4,2.14,73.38,,0,0.001,45.428,0.0598,0.009,0.06,762.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-17",5,2.58,100.88,,0,0.001,60.312,0.0594,0.007,0.0332,1015.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-18",3,1.3,40.9,,0,0.001,25.74,0.0597,0.003,0.0463,433.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-19",2,0.83,33.1,,0,0.001,19.747,0.059,0.005,0.022,332.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-21",4,2.07,69.71,,0,0.001,43.174,0.059,0.007,0.0293,726.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-22",1,0.72,28.08,,0,0.001,17.136,0.06,0.003,0.021,288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-25",2,1.18,30.2,,0,0.001,19.806,0.059,0.004,0.028,333.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-27",3,2.13,95.46,,0,0.001,56.123,0.059,0.006,0.0203,944.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-28",2,0.98,40.5,,0,0.001,24.364,0.0595,0.004,0.054,409.402,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-29",3,1.15,48.23,,0,0.001,28.826,0.059,0.003,0.0397,485.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-30",3,1.85,75.09,,0,0.001,44.47,0.0593,0.005,0.023,748.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-02",3,1.97,41.12,,0,0.001,28.722,0.0593,0.004,0.0213,483.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-04",5,2.42,57.05,,0,0.001,39.022,0.0596,0.005,0.0338,655.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-05",5,2.69,87.81,,0,0.001,55.011,0.0594,0.006,0.0344,925.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-06",2,1.22,26.28,,0,0.001,18.386,0.0595,0.004,0.023,309.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-14",8,4.16,134.74,,0,0.001,84.475,0.0594,0.011,0.0379,1421.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-18",3,1.23,52.72,,0,0.001,31.28,0.0593,0.004,0.0423,526.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-19",3,1.25,53.67,,0,0.001,31.617,0.06,0.004,0.0433,531.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-20",3,1.25,52.8,,0,0.001,31.582,0.0593,0.004,0.0433,530.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-21",3,1.18,49.67,,0,0.001,29.81,0.0593,0.004,0.0923,501.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-25",2,1.25,40.9,,0,0.001,25.655,0.059,0.005,0.029,431.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-26",3,1.98,54.43,,0,0.001,35.482,0.059,0.005,0.0187,597.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-27",3,1.3,57.15,,0,0.001,33.637,0.0593,0.004,0.04,566.641,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-28",3,1.25,53.5,,0,0.001,31.782,0.06,0.004,0.0497,534.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-02-29",3,1.26,54.59,,0,0.001,32.065,0.0593,0.004,0.0373,539.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-01",6,4.24,87.76,,0,0.001,60.974,0.0595,0.006,0.0187,1025.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-03",3,1.8,56.75,,0,0.001,35.21,0.0597,0.004,0.0173,591.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-05",3,1.76,40.76,,0,0.001,27.332,0.059,0.004,0.036,460.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-06",2,1.2,23.15,,0,0.001,16.785,0.0595,0.004,0.0365,282.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-08",2,1.22,24.4,,0,0.001,17.165,0.0595,0.004,0.036,288.463,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-09",5,3.67,74.74,,0,0.001,52.745,0.0592,0.007,0.0194,888.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-10",4,2.44,69.07,,0,0.001,45.086,0.0593,0.006,0.0205,758.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-11",6,3.42,69.79,,0,0.001,49.28,0.0595,0.005,0.0272,828.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-12",7,4.38,180,,0.001,0.001,107.866,0.0591,0.011,0.037,1814.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-13",5,3.44,125.42,,0,0.001,77.821,0.059,0.008,0.0128,1310.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-14",9,7.07,216.05,,0.001,0.001,137.264,0.0593,0.013,0.0141,2310.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-15",7,5.33,194.66,,0.001,0.001,119.245,0.059,0.011,0.0146,2006.641,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-16",6,3.41,123.38,,0,0.001,75.208,0.0592,0.008,0.0305,1266.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-17",3,1.2,23.8,,0,0.001,16.76,0.06,0.002,0.0577,281.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-19",5,3.18,67.5,,0,0.001,46.92,0.0594,0.004,0.0404,789.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-21",4,3.5,79.01,,0,0.001,53.976,0.0593,0.005,0.0108,907.734,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-22",2,1.5,34.02,,0,0.001,22.943,0.0595,0.003,0.016,386.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-23",2,1.28,27.92,,0,0.001,19.383,0.06,0.003,0.02,325.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-24",3,1.32,44.56,,0,0.001,27.812,0.059,0.003,0.042,467.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-26",2,1.45,29.25,,0,0.001,20.57,0.059,0.003,0.015,345.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-28",2,1.39,39.07,,0,0.001,24.939,0.059,0.004,0.0205,420.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-30",5,3.14,65.03,,0,0.001,45.496,0.0592,0.006,0.0186,765.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-01",4,2.39,75.85,,0,0.001,47.137,0.059,0.005,0.0243,794.124,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-02",5,2.44,47.99,,0,0.001,33.902,0.0592,0.004,0.0284,570.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-04",2,1.25,43.7,,0,0.001,26.685,0.059,0.005,0.0285,449.905,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-06",4,2.4,104.82,,0,0.001,61.953,0.0595,0.006,0.025,1041.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-08",6,2.63,82.74,,0,0.001,52.192,0.0593,0.006,0.0537,878.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-09",10,8.3,369.48,,0.001,0.001,217.675,0.0593,0.021,0.0173,3660.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-14",3,1.42,28.42,,0,0.001,19.931,0.059,0.003,0.079,335.223,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-15",2,0.65,11.46,,0,0.001,8.554,0.0595,0.003,0.063,143.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-16",4,2.43,50.37,,0,0.001,35.484,0.0598,0.008,0.029,596.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-17",9,7.97,383.01,,0.001,0.001,220.702,0.0591,0.02,0.0182,3713.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-18",2,1.13,23.16,,0,0.001,16.269,0.059,0.003,0.0245,273.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-21",4,2.42,88.24,,0,0.001,54.037,0.0595,0.009,0.0403,909.349,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-22",4,1.34,30.62,,0,0.001,21.102,0.0595,0.003,0.0448,354.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-23",2,1.26,28.21,,0,0.001,19.102,0.059,0.003,0.02,321.624,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-24",4,2.17,66.18,,0,0.001,41.945,0.0595,0.004,0.0595,704.529,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-25",2,1.16,23.2,,0,0.001,16.414,0.0595,0.003,0.0195,275.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-28",3,1.47,42.84,,0,0.001,27.63,0.059,0.004,0.038,464.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-29",3,1.2,23.5,,0,0.001,16.8,0.059,0.002,0.0577,282.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-08",2,1.15,43.25,,0,0.001,25.907,0.0595,0.005,0.022,435.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-09",4,3.2,90.8,,0,0.001,57.44,0.0593,0.006,0.012,967.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-11",4,2.66,97.76,,0,0.001,58.621,0.059,0.006,0.017,987.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-12",3,1.19,35.84,,0,0.001,22.971,0.0597,0.003,0.0613,385.978,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-13",2,1.5,53.79,,0,0.001,32.538,0.0595,0.004,0.013,547.065,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-14",4,2.29,47.53,,0,0.001,32.75,0.0593,0.006,0.021,551.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-15",2,1.19,33.95,,0,0.001,21.505,0.0595,0.004,0.0225,361.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-16",4,2.72,68.1,,0,0.001,44.703,0.059,0.007,0.0235,753.163,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-26",6,4.64,145.82,,0,0.001,91.732,0.059,0.009,0.0147,1544.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-01",5,2.53,58.06,,0,0.001,38.943,0.0596,0.005,0.0344,654.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-02",3,2.44,58.42,,0,0.001,39.196,0.0597,0.005,0.0163,658.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-03",5,3.31,152.4,,0,0.001,88.003,0.059,0.007,0.0214,1480.579,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-06",2,1.22,28.78,,0,0.001,19.63,0.059,0.003,0.0175,330.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-08",4,2.44,62.85,,0,0.001,41.696,0.0595,0.007,0.0358,701.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-09",3,2.47,78.29,,0,0.001,48.717,0.059,0.005,0.0127,820.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-10",7,5.2,140.8,,0,0.001,90.56,0.0593,0.007,0.0321,1526.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-16",6,4.47,108.5,,0,0.001,72.528,0.0593,0.007,0.0287,1220.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-17",4,2.16,45.12,,0,0.001,31.468,0.0598,0.003,0.0608,528.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-18",3,1.18,23.24,,0,0.001,16.494,0.0593,0.002,0.0593,278.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-20",2,1.2,42.6,,0,0.001,26.4,0.06,0.004,0.016,443.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-23",2,1.22,24.4,,0,0.001,17.154,0.059,0.003,0.025,288.657,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-24",3,1.47,29.7,,0,0.001,20.934,0.0593,0.003,0.0387,352.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-26",5,2.71,66.87,,0,0.001,44.567,0.059,0.005,0.0254,750.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-27",4,3.26,88.36,,0,0.001,57.838,0.0593,0.006,0.013,972.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-06-30",5,2.98,87.95,,0,0.001,56.39,0.0592,0.008,0.0478,949.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-01",24,23.05,513,,0.002,0.001,349.665,0.0593,0.024,0.0138,5885.965,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-02",2,1.68,63.7,,0,0.001,38.574,0.0595,0.004,0.012,648.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-03",3,2.51,111.78,,0,0.001,65.296,0.059,0.006,0.011,1099.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-04",3,1.95,72.35,,0,0.001,44.165,0.059,0.005,0.017,742.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-06",6,4.61,205.32,,0.001,0.001,120.184,0.0593,0.01,0.0308,2022.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-07",3,1.45,39.7,,0,0.001,25.554,0.059,0.003,0.0463,430.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-09",4,2.19,52.48,,0,0.001,35.691,0.0593,0.003,0.0375,600.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-10",7,6.15,279.51,,0.001,0.001,162.473,0.059,0.013,0.0111,2734.301,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-11",8,6.69,305.26,,0.001,0.001,177.08,0.0593,0.014,0.013,2979.373,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-12",9,7.95,351.74,,0.001,0.001,205.141,0.0592,0.015,0.0127,3451.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-13",10,8.22,381.56,,0.001,0.001,219.88,0.059,0.016,0.0218,3702.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-14",3,1.25,25.97,,0,0.001,18.033,0.0597,0.002,0.0463,302.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-15",2,1.28,30.13,,0,0.001,20.197,0.059,0.003,0.0195,339.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-16",2,1.25,26.34,,0,0.001,18.094,0.0595,0.003,0.0165,304.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-18",3,1.5,59.72,,0,0.001,35.794,0.059,0.004,0.029,602.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-22",3,1.97,62.57,,0,0.001,39.131,0.0593,0.005,0.017,658.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-24",3,1.97,42.31,,0,0.001,29.058,0.059,0.003,0.035,489.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-25",3,2.27,85.15,,0,0.001,51.682,0.059,0.005,0.013,870.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-26",3,2.72,102.08,,0,0.001,61.892,0.0593,0.005,0.0107,1041.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-27",5,2.92,66.79,,0,0.001,45.102,0.0592,0.005,0.033,759.457,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-28",2,1.22,36.59,,0,0.001,23.454,0.059,0.005,0.0355,394.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-29",7,5.77,236.18,,0.001,0.001,140.99,0.0596,0.011,0.0133,2370.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-30",9,7.21,304.81,,0.001,0.001,179.597,0.0594,0.014,0.0143,3020.523,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-07-31",11,8.92,359.54,,0.001,0.001,213.928,0.0592,0.015,0.0203,3599.583,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-01",10,8.35,358.3,,0.001,0.001,210.809,0.0593,0.016,0.021,3545.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-03",8,6.12,176.29,,0.001,0.001,113.304,0.0591,0.01,0.0224,1906.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-05",2,1.22,26.14,,0,0.001,18.375,0.0595,0.003,0.0215,309.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-07",2,1.22,29.38,,0,0.001,19.752,0.0595,0.003,0.0195,331.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-08",3,1.72,41.92,,0,0.001,27.985,0.0593,0.004,0.0183,471.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-09",4,2.45,58.3,,0,0.001,39.245,0.0598,0.004,0.026,658.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-10",2,1.41,31.6,,0,0.001,21.556,0.059,0.003,0.016,362.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-11",2,1.27,31.28,,0,0.001,21.145,0.0595,0.004,0.021,355.739,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-12",9,6.83,258.33,,0.001,0.001,154.218,0.0593,0.012,0.0289,2595.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-13",10,8.41,337.45,,0.001,0.001,200.664,0.0592,0.015,0.0176,3376.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-14",12,10.25,454.69,,0.001,0.001,263.482,0.0593,0.019,0.0178,4432.613,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-15",11,9.31,430.55,,0.001,0.001,248.94,0.0591,0.018,0.0129,4190.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-16",9,7.23,334.23,,0.001,0.001,193.701,0.0594,0.014,0.0166,3257.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-17",12,10.2,473.36,,0.001,0.001,274.568,0.0593,0.019,0.0168,4618.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-18",13,11.22,519.62,,0.002,0.001,300.832,0.0593,0.021,0.0122,5060.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-19",14,12.18,570.48,,0.002,0.001,328.07,0.0594,0.023,0.0138,5518.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-20",11,9.18,401.24,,0.001,0.001,234.728,0.0593,0.016,0.0167,3949.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-21",10,8.47,386.2,,0.001,0.001,224.855,0.059,0.016,0.0144,3784.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-22",9,7.27,258.81,,0.001,0.001,157.591,0.0591,0.01,0.0152,2653.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-23",5,4.15,182.15,,0.001,0.001,107.285,0.059,0.008,0.01,1805.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-24",9,7.7,348.7,,0.001,0.001,203.58,0.0592,0.015,0.0137,3424.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-25",9,7.21,332.35,,0.001,0.001,192.635,0.0592,0.014,0.0163,3242.141,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-26",10,8.22,357.76,,0.001,0.001,209.76,0.0591,0.015,0.016,3531.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-27",9,7.48,344.43,,0.001,0.001,200.365,0.0591,0.015,0.0139,3370.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-28",2,1.03,25.32,,0,0.001,17.194,0.0595,0.003,0.0205,289.346,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-29",5,3.3,151.34,,0,0.001,87.749,0.0592,0.007,0.0174,1476.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-30",5,3.3,150.84,,0,0.001,87.4,0.0594,0.007,0.0226,1471.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-08-31",5,3.16,67.2,,0,0.001,46.344,0.0592,0.004,0.043,780.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-02",3,1.2,23.92,,0,0.001,17.044,0.0593,0.002,0.0527,286.236,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-03",8,6.24,285.84,,0.001,0.001,167.824,0.0593,0.012,0.0193,2823.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-04",9,7.45,340.35,,0.001,0.001,198.49,0.0591,0.015,0.016,3341.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-05",12,10.2,450.08,,0.001,0.001,263.74,0.0592,0.019,0.019,4437.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-06",13,11.25,521.48,,0.002,0.001,303.922,0.0592,0.022,0.0219,5114.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-07",9,7.24,333.68,,0.001,0.001,194.144,0.0591,0.014,0.0152,3266.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-08",6,4.3,194.8,,0.001,0.001,113.21,0.059,0.009,0.0197,1905.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-09",4,2.36,67.87,,0,0.001,43.511,0.0595,0.005,0.023,732.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-12",3,1.42,28.32,,0,0.001,19.866,0.0593,0.003,0.048,335.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-13",2,1.19,33.62,,0,0.001,21.736,0.0595,0.003,0.0175,365.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-14",4,2.7,110.98,,0,0.001,65.908,0.059,0.006,0.0315,1110.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-15",6,4.41,170.37,,0.001,0.001,102.507,0.0595,0.009,0.0188,1723.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-16",2,1.22,37.6,,0,0.001,23.839,0.06,0.003,0.015,400.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-17",7,5.72,205.58,,0.001,0.001,124.26,0.0591,0.01,0.0194,2091.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-18",10,9.72,379.16,,0.001,0.001,226.187,0.0593,0.016,0.0092,3805.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-19",7,5.78,205.82,,0.001,0.001,124.528,0.059,0.009,0.0127,2095.982,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-20",3,2.2,75,,0,0.001,45.852,0.0593,0.005,0.015,771.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-21",6,4.67,121.58,,0,0.001,78.843,0.0595,0.007,0.0115,1325.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-22",2,1.48,30.23,,0,0.001,20.761,0.059,0.003,0.0165,349.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-23",5,3.23,146.89,,0,0.001,84.849,0.0594,0.006,0.0254,1426.831,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-24",3,1.3,55.08,,0,0.001,32.023,0.0593,0.004,0.0323,538.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-25",4,2.35,95.6,,0,0.001,56.591,0.0593,0.006,0.0443,952.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-26",3,1.2,49.24,,0,0.001,29.4,0.059,0.003,0.043,494.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-27",2,1.19,23.85,,0,0.001,16.442,0.059,0.003,0.019,277.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-28",5,4.18,135.23,,0,0.001,83.783,0.0592,0.007,0.0112,1410.441,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-29",9,7.63,354.09,,0.001,0.001,205.146,0.0592,0.015,0.0186,3453.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-09-30",10,8.22,364.84,,0.001,0.001,210.584,0.059,0.015,0.0163,3543.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-01",9,7.24,335.68,,0.001,0.001,194.248,0.0592,0.014,0.0174,3266.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-02",9,7.22,332.76,,0.001,0.001,192.344,0.0593,0.014,0.0189,3236.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-03",5,3.14,102.25,,0,0.001,63.361,0.0594,0.006,0.034,1065.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-04",5,4.06,171.42,,0.001,0.001,100.152,0.0592,0.008,0.0298,1685.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-05",8,6.13,261.76,,0.001,0.001,152.841,0.0594,0.013,0.0185,2571.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-06",13,11.15,326.92,,0.001,0.001,208.827,0.0594,0.016,0.0143,3512.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-07",5,3.25,146.86,,0,0.001,85.684,0.0592,0.006,0.0228,1442.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-08",3,1.66,36.34,,0,0.001,25.096,0.0593,0.004,0.0467,423.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-09",3,2.75,74.65,,0,0.001,48.62,0.0593,0.005,0.0127,818.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-10",3,1.29,26.9,,0,0.001,18.903,0.0593,0.002,0.0343,317.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-12",6,5.35,210.96,,0.001,0.001,126.17,0.0593,0.011,0.0118,2122.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-13",5,3.44,79.77,,0,0.001,54.684,0.0596,0.005,0.0334,919.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-14",5,4.44,160.26,,0,0.001,97.622,0.0592,0.008,0.0108,1642.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-15",5,3.7,155.74,,0,0.001,92.46,0.059,0.008,0.0262,1555.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-16",6,4.19,93.16,,0,0.001,63.867,0.0593,0.005,0.0312,1074.991,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-17",2,1.15,23.28,,0,0.001,16.759,0.059,0.003,0.03,282.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-20",2,1.27,26.76,,0,0.001,18.981,0.059,0.002,0.0165,319.169,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-21",2,1.27,27.68,,0,0.001,19.349,0.0595,0.002,0.015,325.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-23",2,1.17,26.22,,0,0.001,17.97,0.0595,0.003,0.0205,302.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-24",2,1.22,26.28,,0,0.001,18.264,0.059,0.003,0.0175,307.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-25",2,1.18,34.6,,0,0.001,22.024,0.0595,0.003,0.016,370.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-26",5,3.04,84.63,,0,0.001,54.822,0.0592,0.007,0.0212,922.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-27",5,2.69,89.88,,0,0.001,55.609,0.059,0.007,0.0288,936.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-28",4,2.25,91.22,,0,0.001,54.34,0.0593,0.005,0.036,914.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-01",2,0.61,11.16,,0,0.001,8.271,0.059,0.002,0.0445,139.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-13",2,1.12,31.04,,0,0.001,20.016,0.06,0.003,0.022,336.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-15",2,0.63,15.95,,0,0.001,10.544,0.059,0.003,0.07,177.699,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-16",4,2.18,47.68,,0,0.001,32.468,0.0595,0.003,0.0553,545.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-17",2,1.27,28.47,,0,0.001,19.569,0.059,0.004,0.0215,329.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-18",3,1.22,24.02,,0,0.001,17.178,0.0593,0.002,0.055,288.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-20",2,1.22,24.22,,0,0.001,17.269,0.059,0.003,0.019,290.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-21",2,1.19,23.8,,0,0.001,16.697,0.059,0.003,0.027,281.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-22",3,2.2,46,,0,0.001,31.8,0.0593,0.004,0.023,535.407,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-24",6,2.62,52.52,,0,0.001,37.49,0.0595,0.005,0.0593,630.883,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-25",4,2.44,50.18,,0,0.001,35.478,0.0598,0.005,0.018,596.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-27",2,1.13,22.6,,0,0.001,16.357,0.059,0.004,0.0365,275.185,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-28",2,1.23,24.98,,0,0.001,17.826,0.0595,0.004,0.0325,299.589,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-29",2,1.2,25.2,,0,0.001,17.4,0.059,0.004,0.0345,292.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-11-30",5,3.12,65.49,,0,0.001,45.819,0.0592,0.006,0.0348,770.887,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-01",5,2.38,51.08,,0,0.001,36.187,0.0592,0.005,0.0432,609.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-02",3,1.68,40.16,,0,0.001,27.288,0.059,0.004,0.0453,459.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-03",6,4.25,101.15,,0,0.001,68.555,0.0592,0.006,0.027,1153.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-04",4,2.46,48.62,,0,0.001,34.821,0.0595,0.005,0.0193,585.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-05",2,1.17,23.4,,0,0.001,16.561,0.06,0.003,0.033,278.197,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-06",3,1.43,29,,0,0.001,20.22,0.0597,0.003,0.0403,340.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-07",5,2.6,51.58,,0,0.001,36.356,0.0592,0.006,0.0356,612.503,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-08",5,2.46,71.36,,0,0.001,45.48,0.059,0.006,0.0284,765.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-09",2,1.22,24.4,,0,0.001,17.117,0.0595,0.003,0.0305,287.566,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-10",5,2.44,60.66,,0,0.001,40.314,0.059,0.006,0.0368,678.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-11",7,5.35,211.49,,0.001,0.001,126.678,0.059,0.01,0.0136,2132.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-12",6,4.45,186.04,,0.001,0.001,110.632,0.0593,0.016,0.0297,1860.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-13",2,1.13,22.32,,0,0.001,15.877,0.06,0.003,0.03,266.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-14",4,2.31,47.11,,0,0.001,33.373,0.0593,0.005,0.0213,561.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-15",5,2.52,70.33,,0,0.001,45.567,0.0594,0.006,0.0288,767.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-16",10,7.31,177.16,,0.001,0.001,118.441,0.0592,0.012,0.0211,1993.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-18",2,1.22,33.39,,0,0.001,21.697,0.059,0.005,0.029,365.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-22",6,5.18,229.44,,0.001,0.001,133.99,0.0593,0.012,0.0127,2254.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-23",2,1.2,23.55,,0,0.001,16.947,0.06,0.003,0.022,284.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-27",4,2.36,45.92,,0,0.001,32.864,0.0593,0.005,0.0205,552.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-28",8,5.71,236.93,,0.001,0.001,141.136,0.0593,0.015,0.0246,2375.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"1",,"2020-12-31",1,0.58,9.86,,0,0.001,7.482,0.06,0.004,0.061,125.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-17",4,2.52,96.79,,0,0.001,60.303,0.0593,0.006,0.0238,1014.627,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-18",3,1.28,42.34,,0,0.001,26.856,0.059,0.004,0.0307,452.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-21",2,1.22,32.92,,0,0.001,22.02,0.0595,0.002,0.0125,370.854,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-23",2,1.47,50.69,,0,0.001,31.581,0.059,0.003,0.012,531.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-25",2,1.18,28.55,,0,0.001,19.316,0.0595,0.003,0.0205,324.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-28",3,1.23,45.72,,0,0.001,28.389,0.0593,0.003,0.037,477.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-30",5,2.45,100.56,,0,0.001,61.352,0.0594,0.008,0.0406,1032.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-01-31",6,4.2,154.76,,0,0.001,96.64,0.0593,0.009,0.0237,1626.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-02",3,1.97,40.29,,0,0.001,28.947,0.059,0.004,0.021,487.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-03",4,2.4,46.47,,0,0.001,34.123,0.059,0.007,0.058,574.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-04",5,2.42,57.08,,0,0.001,39.881,0.059,0.008,0.0566,671.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-05",5,3.14,103.03,,0,0.001,66.633,0.0596,0.009,0.0368,1120.117,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-08",3,1.72,38.33,,0,0.001,26.69,0.059,0.004,0.0253,449.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-10",2,1.15,23,,0,0.001,16.394,0.0595,0.004,0.0345,275.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-11",3,1.22,29.8,,0,0.001,20.542,0.059,0.003,0.0607,345.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-12",2,1.18,22.75,,0,0.001,16.789,0.059,0.004,0.0325,282.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-13",3,1.45,30.11,,0,0.001,21.381,0.06,0.004,0.049,358.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-14",4,2.4,60.5,,0,0.001,41.325,0.059,0.007,0.0188,695.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-15",2,1.22,25.09,,0,0.001,17.774,0.059,0.003,0.0225,299.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-16",3,1.28,28.28,,0,0.001,19.364,0.059,0.003,0.0423,326.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-17",2,1.17,29.31,,0,0.001,19.521,0.059,0.003,0.021,328.737,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-21",2,1.13,21.47,,0,0.001,15.765,0.059,0.003,0.0305,265.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-23",3,1.75,34.9,,0,0.001,25.205,0.059,0.003,0.034,424.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-24",2,1.17,51.34,,0,0.001,30.949,0.059,0.004,0.0155,520.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-25",2,1.25,27.4,,0,0.001,19.5,0.0595,0.003,0.0225,328.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-26",2,1.77,50.9,,0,0.001,33.302,0.0595,0.005,0.0155,559.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-01",6,4.2,100.1,,0,0.001,69.125,0.0592,0.006,0.0223,1163.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-03",6,3.25,87.27,,0,0.001,57.348,0.059,0.007,0.0487,966.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-05",3,1.77,40.62,,0,0.001,27.907,0.0593,0.004,0.0313,470.547,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-06",2,1.2,23.15,,0,0.001,17.145,0.0595,0.004,0.0395,288.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-09",5,3.65,73.86,,0,0.001,53.497,0.0592,0.008,0.0212,900.043,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-10",2,1.22,22.83,,0,0.001,17.114,0.059,0.004,0.0335,288.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-11",5,3.42,94.14,,0,0.001,62.065,0.0594,0.007,0.0268,1043.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-12",7,4.38,184.48,,0.001,0.001,113.507,0.0593,0.011,0.0297,1910.497,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-13",5,3.47,126.13,,0,0.001,80.514,0.059,0.009,0.0144,1356.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-14",9,7.07,213.57,,0.001,0.001,141.67,0.0594,0.013,0.0161,2381.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-15",9,7.66,327.73,,0.001,0.001,201.727,0.0592,0.017,0.0113,3394.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-16",6,3.66,135.23,,0,0.001,84.111,0.059,0.01,0.0245,1416.351,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-17",3,1.2,23.68,,0,0.001,16.92,0.06,0.003,0.08,284.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-21",5,2.92,60.86,,0,0.001,43.889,0.059,0.006,0.057,739.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-22",2,1.5,33.19,,0,0.001,23.543,0.059,0.004,0.019,396.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-23",2,1.28,30.13,,0,0.001,20.709,0.0595,0.003,0.02,347.749,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-24",7,4.34,107.94,,0,0.001,74.08,0.0594,0.009,0.033,1245.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-26",2,1.7,33.15,,0,0.001,24.48,0.0595,0.004,0.0175,411.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-28",3,1.38,30.14,,0,0.001,21.278,0.0593,0.003,0.044,358.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-30",2,1.2,23.3,,0,0.001,16.962,0.0595,0.003,0.022,284.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-01",4,2.37,76.35,,0,0.001,49.013,0.0593,0.005,0.0273,824.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-02",5,2.42,47.59,,0,0.001,34.212,0.0592,0.004,0.0336,575.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-04",2,1.25,42.8,,0,0.001,27.205,0.059,0.005,0.0255,457.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-05",13,12.03,494.05,,0.002,0.001,299.061,0.0592,0.02,0.0139,5031.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-06",6,3.65,148.59,,0,0.001,90.426,0.0592,0.008,0.0248,1520.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-07",5,2.95,82.54,,0,0.001,54.175,0.0596,0.008,0.0446,911.297,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-08",6,2.35,75.39,,0,0.0008,48.757,0.0595,0.007,0.0475,819.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-09",10,8.27,375.67,,0.001,0.001,228.168,0.0594,0.02,0.0141,3838.327,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-14",11,9.15,449.84,,0.001,0.001,267.612,0.0592,0.021,0.0227,4502.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-16",5,2.43,52.49,,0,0.001,37.061,0.0592,0.007,0.0474,623.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-17",2,1.22,24.03,,0,0.001,17.139,0.0595,0.004,0.0325,287.851,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-21",4,2.42,88.01,,0,0.001,55.669,0.059,0.011,0.0428,936.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-22",4,1.32,25.42,,0,0.001,18.662,0.0593,0.002,0.0465,313.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-23",2,1.25,26.69,,0,0.001,19.218,0.0595,0.003,0.024,323.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-24",4,2.38,73.36,,0,0.001,47.532,0.059,0.004,0.0288,800.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-25",2,1.16,23.2,,0,0.001,16.704,0.059,0.003,0.0195,281.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-26",2,1.09,29.11,,0,0.001,19.324,0.0595,0.003,0.0245,324.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-28",3,1.72,49.49,,0,0.001,32.723,0.059,0.004,0.0197,550.887,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-29",3,1.2,24.3,,0,0.001,17.41,0.059,0.002,0.067,293.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-08",2,1.15,43.78,,0,0.001,27.189,0.0595,0.005,0.0205,457.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-09",6,4.3,108.8,,0,0.001,73.61,0.0592,0.008,0.028,1239.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-10",1,0.1,0.3,,0,0.001,0.66,0.06,0,0.052,11.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-11",7,3.6,109.56,,0,0.001,71.012,0.0591,0.008,0.0433,1195.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-12",5,3.04,76.84,,0,0.001,52.405,0.0594,0.006,0.0182,881.682,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-13",3,1.95,66.15,,0,0.001,41.75,0.059,0.004,0.0133,702.598,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-14",4,2.28,48.45,,0,0.001,34.314,0.0598,0.005,0.018,576.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-15",5,2.34,55.59,,0,0.001,38.218,0.0592,0.007,0.0552,642.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-16",4,2.73,67.32,,0,0.001,46.093,0.0593,0.006,0.0203,776.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-01",5,2.75,57.88,,0,0.001,41.009,0.0594,0.006,0.0432,690.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-02",5,3.53,92.01,,0,0.001,62.311,0.0592,0.004,0.0178,1047.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-03",5,2.38,48.37,,0,0.001,34.726,0.0594,0.004,0.048,584.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-04",5,3.17,67.36,,0,0.001,47.833,0.0596,0.005,0.0224,803.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-06",2,1.22,28.16,,0,0.001,19.99,0.0595,0.003,0.016,336.276,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-08",2,1.23,41.47,,0,0.001,26.568,0.059,0.004,0.0145,447.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-09",3,2.49,79.12,,0,0.001,50.778,0.059,0.004,0.0103,856.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-10",7,6.39,171.54,,0.001,0.001,114.71,0.0593,0.009,0.0099,1930.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-11",2,1.2,24,,0,0.001,17.58,0.0595,0.003,0.021,295.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-12",2,1.22,25.09,,0,0.001,18.123,0.0595,0.002,0.0145,304.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-16",5,2.43,58.09,,0,0.001,40.581,0.0596,0.007,0.0388,682.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-17",7,5.15,116.2,,0,0.001,81.175,0.0591,0.006,0.0336,1366.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-18",3,1.15,23.78,,0,0.001,16.951,0.0593,0.002,0.0667,284.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-19",2,1.16,24.03,,0,0.001,17.086,0.059,0.002,0.0235,287.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-20",2,1.2,44.4,,0,0.001,28.14,0.06,0.004,0.0155,472.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-22",2,1.47,40.17,,0,0.001,26.76,0.059,0.004,0.015,451.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-23",2,1.22,30.31,,0,0.001,20.611,0.0595,0.002,0.0115,346.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-24",2,1.08,20.98,,0,0.001,15.626,0.06,0.002,0.0185,262.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-26",4,2.69,58.26,,0,0.001,40.976,0.059,0.004,0.0128,690.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-27",5,3.51,93.04,,0,0.001,63.442,0.0592,0.005,0.0228,1066.636,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-29",2,1.22,31.2,,0,0.001,21.13,0.059,0.004,0.0225,355.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-06-30",3,1.98,74.18,,0,0.001,46.932,0.059,0.005,0.017,789.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-01",3,1.96,77.02,,0,0.001,48.596,0.0593,0.006,0.0197,818.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-02",2,1.45,52.75,,0,0.001,33.735,0.06,0.004,0.0155,566.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-03",3,2.53,116.15,,0,0.001,71.076,0.0597,0.006,0.0107,1194.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-04",3,1.95,73.72,,0,0.001,46.341,0.0593,0.005,0.0147,778.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-05",6,3.88,122.67,,0,0.001,79.034,0.059,0.007,0.0125,1329.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-06",3,2.2,87.54,,0,0.001,54.48,0.06,0.005,0.013,915.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-07",3,1.94,56.44,,0,0.001,37.455,0.059,0.004,0.0163,630.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-08",2,1.2,24.42,,0,0.001,17.568,0.059,0.002,0.0145,296.037,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-09",4,2.19,52.92,,0,0.001,36.39,0.0593,0.003,0.032,612.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-10",6,4.73,218.62,,0.001,0.001,133.259,0.059,0.01,0.0125,2241.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-11",6,5.19,224.61,,0.001,0.001,136.788,0.059,0.009,0.0088,2301.849,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-12",6,4.7,215.36,,0.001,0.001,129.886,0.0592,0.008,0.0112,2186.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-13",8,5.73,265.36,,0.001,0.001,160.145,0.0594,0.01,0.016,2692.987,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-14",3,1.22,23.95,,0,0.001,17.635,0.0593,0.002,0.0373,297.523,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-15",2,1.27,29.19,,0,0.001,20.183,0.0595,0.003,0.017,339.219,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-18",3,1.51,63.48,,0,0.001,38.977,0.0593,0.004,0.017,655.965,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-21",3,1.22,26.46,,0,0.001,18.864,0.06,0.002,0.028,316.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-22",3,1.72,41.79,,0,0.001,29.249,0.0593,0.003,0.0123,491.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-24",3,1.97,43.31,,0,0.001,30.62,0.059,0.003,0.0263,515.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-25",3,2.28,88.88,,0,0.001,55.408,0.0593,0.004,0.0097,932.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-26",3,2.72,108.52,,0,0.001,67.057,0.059,0.005,0.0087,1129.574,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-28",5,3.18,83.5,,0,0.001,56.266,0.0594,0.004,0.0338,946.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-29",5,3.43,111.45,,0,0.001,72.047,0.0592,0.006,0.0186,1212.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-30",8,6.89,299.88,,0.001,0.001,184.671,0.059,0.013,0.0125,3110.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-07-31",10,8.44,367.64,,0.001,0.001,225.88,0.0591,0.015,0.0155,3803.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-01",8,6.36,239.84,,0.001,0.001,151.252,0.0593,0.009,0.0323,2544.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-03",4,2.62,59.06,,0,0.001,41.535,0.059,0.004,0.0123,700.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-05",2,1.22,27.84,,0,0.001,19.569,0.0595,0.003,0.0205,329.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-07",2,1.22,29.98,,0,0.001,20.662,0.0595,0.004,0.019,347.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-08",3,1.74,42.24,,0,0.001,29.461,0.0593,0.004,0.018,496.132,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-09",4,2.45,59.68,,0,0.001,41.151,0.0593,0.004,0.0208,691.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-10",2,1.43,31.19,,0,0.001,22.254,0.06,0.002,0.014,373.653,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-11",2,1.23,31.03,,0,0.001,21.13,0.059,0.003,0.0155,355.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-12",6,4.67,136.14,,0,0.001,89.899,0.059,0.006,0.0103,1514.229,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-13",9,7.68,242.88,,0.001,0.001,157.602,0.0592,0.009,0.0099,2652.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-14",11,9.25,421.12,,0.001,0.001,256.707,0.0593,0.014,0.011,4317.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-15",10,8.24,395.68,,0.001,0.001,239.94,0.0591,0.014,0.012,4035.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-16",8,6.53,312.9,,0.001,0.001,190.258,0.0596,0.013,0.0121,3199.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-17",11,9.2,444.08,,0.001,0.001,268.284,0.059,0.016,0.0137,4516.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-18",12,10.7,491.9,,0.002,0.001,299.574,0.0593,0.018,0.0087,5042.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-19",13,11.15,539.8,,0.002,0.001,325.065,0.0592,0.02,0.0164,5470.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-20",10,8.13,368.49,,0.001,0.001,222.252,0.0594,0.013,0.015,3737.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-21",9,7.47,353.1,,0.001,0.001,215.604,0.059,0.013,0.0128,3630.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-22",5,3.22,71.08,,0,0.001,51.094,0.0594,0.003,0.0206,860.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-23",5,3.43,154.87,,0,0.001,95.388,0.0592,0.006,0.021,1606.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-24",8,7.22,326.9,,0.001,0.001,200.648,0.0591,0.013,0.0088,3375.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-25",8,6.43,301.86,,0.001,0.001,183.026,0.059,0.012,0.0108,3079.197,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-26",9,7.22,322.12,,0.001,0.001,197.548,0.0591,0.012,0.0123,3325.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-27",9,7.48,354.52,,0.001,0.001,214.681,0.0592,0.014,0.0111,3613.109,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-28",2,1.03,26.35,,0,0.001,18.086,0.059,0.002,0.014,304.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-02",3,1.2,23.92,,0,0.001,17.472,0.059,0.001,0.026,294.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-03",5,3.24,151.32,,0,0.001,92.736,0.0594,0.006,0.0172,1558.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-04",8,6.47,305.39,,0.001,0.001,185.942,0.059,0.011,0.0114,3130.043,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-05",11,9.21,419.98,,0.001,0.001,256.792,0.0591,0.015,0.0124,4322.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-06",3,1.8,85.22,,0,0.001,51.684,0.059,0.004,0.0063,869.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-07",5,3.3,146.88,,0,0.001,89.549,0.0592,0.007,0.01,1506.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-09",4,2.38,74.53,,0,0.001,47.817,0.059,0.006,0.0208,804.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-12",3,1.4,28.08,,0,0.001,20.536,0.0597,0.002,0.051,345.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-13",4,2.39,57.79,,0,0.001,39.931,0.059,0.006,0.0173,672.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-14",4,2.7,114.98,,0,0.001,71.004,0.0593,0.005,0.0143,1194.972,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-15",6,4.42,176.88,,0.001,0.001,110.302,0.0595,0.008,0.0117,1856.483,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-16",2,1.22,39.19,,0,0.001,25.355,0.059,0.003,0.0125,426.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-17",7,5.72,215.3,,0.001,0.001,134.662,0.0594,0.01,0.0147,2265.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-18",10,9.72,392.73,,0.001,0.001,241.718,0.0592,0.015,0.0081,4067.791,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-19",4,3.49,146.05,,0,0.001,89.291,0.0593,0.008,0.0115,1502.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-20",3,2.21,78.55,,0,0.001,49.198,0.059,0.004,0.0117,828.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-21",6,4.65,127.2,,0,0.001,84.405,0.0592,0.006,0.009,1421.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-22",3,1.52,35.9,,0,0.001,24.932,0.0597,0.003,0.0227,419.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-23",5,3.23,151.75,,0,0.001,91.59,0.0592,0.006,0.0276,1541.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-24",3,1.3,56.73,,0,0.001,34.559,0.059,0.003,0.0233,581.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-04",5,3.24,102.92,,0,0.001,66.678,0.0594,0.007,0.0272,1121.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-05",7,5.62,232.7,,0.001,0.001,143.261,0.0591,0.01,0.0096,2411.113,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-06",12,10.14,246.14,,0.001,0.001,170.388,0.0594,0.012,0.0151,2867.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-07",5,3.24,74.95,,0,0.001,52.698,0.0592,0.004,0.0166,887.745,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-08",3,1.68,38,,0,0.001,26.836,0.0593,0.003,0.0163,451.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-09",3,2.73,75.61,,0,0.001,51.085,0.0597,0.004,0.0097,858.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-10",3,1.27,26.09,,0,0.001,18.716,0.059,0.002,0.0297,315.613,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-12",6,5.35,216.96,,0.001,0.001,135.305,0.0593,0.01,0.0098,2275.559,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-13",5,3.44,79.77,,0,0.001,55.454,0.0594,0.004,0.017,932.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-14",5,4.44,155.26,,0.001,0.001,99.409,0.0594,0.007,0.0084,1672.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-15",5,3.95,167.62,,0.001,0.001,103.178,0.0596,0.007,0.0122,1735.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-16",6,4.19,92.44,,0,0.001,64.586,0.0592,0.004,0.021,1088.057,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-17",2,1.2,25.2,,0,0.001,18.12,0.0595,0.002,0.013,304.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-20",2,1.27,28.03,,0,0.001,19.997,0.06,0.002,0.012,335.657,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-21",2,1.29,28,,0,0.001,20.211,0.059,0.003,0.016,340.381,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-23",2,1.2,24.3,,0,0.001,18.015,0.06,0.003,0.018,302.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-24",2,1.22,26.26,,0,0.001,18.866,0.059,0.003,0.017,317.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-25",2,1.18,32.28,,0,0.001,21.984,0.059,0.003,0.017,370.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-26",6,3.52,101.29,,0,0.001,67.353,0.059,0.007,0.028,1133.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-27",5,3.45,131.99,,0,0.001,82.221,0.059,0.009,0.0138,1383.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-01",2,0.61,10.98,,0,0.001,8.339,0.059,0.002,0.044,140.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-13",2,1.18,41.41,,0,0.001,26.176,0.059,0.006,0.023,441.141,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-15",2,0.62,11,,0,0.001,8.346,0.0595,0.003,0.0875,140.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-17",5,2.92,67.02,,0,0.001,46.9,0.0592,0.008,0.0432,788.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-18",5,2.4,75.77,,0,0.001,48.625,0.0592,0.006,0.031,818.182,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-20",2,1.22,24.4,,0,0.001,17.616,0.0595,0.003,0.028,296.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-21",5,2.41,48.12,,0,0.001,34.902,0.0594,0.006,0.0548,586.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-22",6,3.86,79.49,,0,0.001,57.535,0.0593,0.007,0.019,967.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-24",5,2.63,52.9,,0,0.001,38.477,0.0592,0.005,0.0282,647.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-25",4,2.44,50.18,,0,0.001,36.175,0.0598,0.005,0.017,607.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-26",2,1.15,22.4,,0,0.001,16.63,0.0595,0.003,0.02,279.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-27",2,1.13,22.6,,0,0.001,16.357,0.0595,0.003,0.0325,275.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-28",2,1.23,24.6,,0,0.001,17.835,0.0595,0.004,0.032,299.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-29",5,2.92,59.69,,0,0.001,42.964,0.0594,0.006,0.0232,722.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-11-30",5,3.33,68.81,,0,0.001,49.545,0.0594,0.006,0.0184,832.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-01",7,3.38,73.2,,0,0.001,52.422,0.0594,0.006,0.0624,882.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-02",3,1.68,40.08,,0,0.001,28.172,0.0593,0.005,0.0547,474.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-03",6,4.25,101.4,,0,0.001,71.285,0.0597,0.006,0.0283,1197.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-04",4,2.44,63.04,,0,0.001,43.088,0.059,0.005,0.0363,725.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-05",2,1.17,23.4,,0,0.001,16.699,0.0595,0.004,0.039,280.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-06",3,1.43,28.9,,0,0.001,20.596,0.0597,0.004,0.0537,346.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-07",5,2.67,55.11,,0,0.001,38.732,0.0592,0.006,0.0298,652.293,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-08",5,2.44,71.89,,0,0.001,47.27,0.0594,0.005,0.0242,795.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-09",4,2.42,50.89,,0,0.001,35.913,0.0593,0.005,0.019,604.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-10",5,2.46,60.98,,0,0.001,42.136,0.0594,0.006,0.035,708.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-11",7,5.35,215.9,,0.001,0.001,133.17,0.0594,0.01,0.0207,2241.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-12",5,3.9,145.81,,0,0.001,91.308,0.059,0.009,0.0118,1536.559,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-14",4,2.35,53.54,,0,0.001,37.249,0.059,0.005,0.0298,627.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-15",5,2.52,67.2,,0,0.001,45.401,0.0592,0.005,0.0322,763.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-16",4,3.14,79.52,,0,0.001,53.214,0.0593,0.006,0.015,895.411,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-17",6,4.2,90.12,,0,0.001,63.112,0.0593,0.005,0.0315,1061.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-18",2,1.27,32.37,,0,0.001,21.97,0.059,0.004,0.0215,370.183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-19",2,1.22,24.74,,0,0.001,18.209,0.06,0.003,0.0205,305.859,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-22",6,5.18,238.62,,0.001,0.001,143.018,0.0592,0.012,0.0122,2406.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-23",2,1.2,22.68,,0,0.001,16.839,0.0595,0.003,0.023,283.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-27",4,2.23,42.97,,0,0.001,31.359,0.0595,0.004,0.0195,527.227,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-28",6,5.18,209.7,,0.001,0.001,129.358,0.0592,0.01,0.0097,2176.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"2",,"2020-12-31",1,0.62,10.54,,0,0.001,7.874,0.059,0.003,0.048,132.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-07",11,9.2,461.72,,0.001,0.001,262.324,0.0593,0.019,0.0203,4416.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-23",2,1.15,44.3,,0,0.001,26.49,0.059,0.004,0.0265,446.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-25",2,1.27,26.54,,0,0.001,17.969,0.06,0.002,0.012,301.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-28",3,1.25,41.85,,0,0.001,25.505,0.059,0.003,0.0287,429.365,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-30",5,2.47,100.25,,0,0.001,59.038,0.0594,0.006,0.0308,994.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-01-31",6,4.21,153.38,,0,0.001,91.775,0.0592,0.007,0.0213,1544.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-02",3,1.45,29.35,,0,0.001,20.095,0.059,0.003,0.0473,338.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-03",5,2.72,60.37,,0,0.001,40.019,0.0594,0.005,0.024,674.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-04",5,2.42,57.81,,0,0.001,38.292,0.0598,0.005,0.0282,643.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-05",3,1.95,63.2,,0,0.001,38.5,0.0593,0.004,0.019,648.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-08",3,1.7,39.1,,0,0.001,25.845,0.0593,0.003,0.016,434.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-09",5,2.45,56.39,,0,0.001,37.407,0.0596,0.005,0.0266,629.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-10",2,1.2,24.04,,0,0.001,16.336,0.059,0.003,0.0215,275.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-11",3,1.23,30.68,,0,0.001,19.934,0.0593,0.002,0.0327,335.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-12",4,2.5,49.3,,0,0.001,33.805,0.0595,0.004,0.0143,568.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-13",3,1.45,30.93,,0,0.001,20.942,0.0597,0.003,0.0227,351.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-14",4,2.4,75.13,,0,0.001,46.135,0.0593,0.005,0.012,777.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-15",2,1.22,25.09,,0,0.001,17.216,0.059,0.002,0.012,290.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-16",3,1.28,27.08,,0,0.001,18.276,0.0597,0.002,0.023,306.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-17",2,1,23.38,,0,0.001,15.308,0.06,0.002,0.0285,256.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-18",3,1.22,27.62,,0,0.001,18.152,0.059,0.002,0.0263,305.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-19",2,1.26,30,,0,0.001,19.726,0.06,0.003,0.014,331.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-20",2,1.47,29.67,,0,0.001,20.421,0.059,0.003,0.014,343.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-21",2,1.13,22.32,,0,0.001,15.313,0.0595,0.002,0.026,257.441,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-23",3,1.98,41.3,,0,0.001,28.127,0.0593,0.003,0.025,473.199,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-24",2,1.75,39.5,,0,0.001,26.4,0.0595,0.002,0.0105,443.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-25",2,1.27,28.77,,0,0.001,18.873,0.0595,0.003,0.021,317.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-26",3,2.27,63.5,,0,0.001,39.481,0.06,0.004,0.0117,662.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-01",4,3.05,78.95,,0,0.001,50.33,0.059,0.004,0.0095,848.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-02",5,3.51,89.72,,0,0.001,56.637,0.0592,0.005,0.014,953.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-03",6,3.27,86.72,,0,0.001,54.624,0.0592,0.005,0.0275,919.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-04",4,2.69,62.12,,0,0.001,40.608,0.0595,0.004,0.0145,683.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-05",2,1.5,34.85,,0,0.001,22.608,0.0595,0.003,0.0145,380.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-06",4,2.5,54.96,,0,0.001,36.514,0.059,0.005,0.0203,614.973,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-09",5,2.87,66.73,,0,0.001,43.673,0.0594,0.005,0.0236,734.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-10",4,2.44,71.9,,0,0.001,45.007,0.0593,0.005,0.0183,757.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-11",6,3.93,101.33,,0,0.001,65.205,0.0595,0.006,0.0243,1096.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-12",7,4.94,207.69,,0.001,0.001,121.924,0.0593,0.009,0.0143,2053.327,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-13",5,3.48,125.54,,0,0.001,76.208,0.0594,0.007,0.0122,1282.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-14",9,7.07,221.69,,0.001,0.001,136.79,0.0594,0.011,0.0128,2300.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-15",10,8.29,352.16,,0.001,0.001,206.357,0.0592,0.014,0.0112,3473.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-16",7,4.4,170.12,,0.001,0.001,100.364,0.0593,0.009,0.0216,1687.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-17",5,3.52,77.64,,0,0.001,51.372,0.0594,0.005,0.0274,863.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-19",2,1.22,25.64,,0,0.001,17.27,0.0595,0.003,0.0175,290.362,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-20",2,1.12,22.89,,0,0.001,15.463,0.059,0.002,0.016,260.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-21",3,1.98,40.61,,0,0.001,27.827,0.0597,0.003,0.0153,467.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-22",2,1.78,41.3,,0,0.001,27.058,0.059,0.003,0.0115,455.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-23",2,1.3,30.47,,0,0.001,19.84,0.059,0.002,0.0125,333.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-24",3,1.32,45.66,,0,0.001,27.872,0.06,0.003,0.02,468.222,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-26",3,2.28,47.6,,0,0.001,32.136,0.0593,0.003,0.0133,541.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-28",3,1.62,36.86,,0,0.001,24.746,0.06,0.004,0.0243,415.178,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-30",5,3.14,65.76,,0,0.001,44.282,0.0596,0.005,0.013,744.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-01",5,2.44,76.88,,0,0.001,47.392,0.0592,0.005,0.0264,796.808,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-02",5,2.44,48.56,,0,0.001,33.481,0.0592,0.003,0.0206,563.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-04",3,1.99,73.6,,0,0.001,43.714,0.0593,0.005,0.0147,734.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-05",16,13.6,545.86,,0.002,0.001,318.743,0.0592,0.023,0.0199,5362.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-06",9,5.24,176.5,,0.001,0.001,106.574,0.0593,0.009,0.0228,1792.981,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-07",5,3.21,85.56,,0,0.001,54.19,0.0596,0.007,0.0274,910.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-08",5,2.49,95.25,,0,0.001,56.462,0.0594,0.006,0.0166,949.419,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-09",10,7.12,308.92,,0.001,0.001,180.43,0.0593,0.015,0.0128,3033.982,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-12",2,1.18,24.22,,0,0.001,16.536,0.0595,0.003,0.0195,278.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-14",3,1.95,40.38,,0,0.001,27.305,0.0597,0.004,0.0233,458.613,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-15",11,9.13,450.3,,0.001,0.001,259.559,0.0591,0.017,0.031,4370.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-16",5,2.4,48.15,,0,0.001,32.866,0.0592,0.007,0.0494,553.065,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-17",2,1.22,24.77,,0,0.001,16.703,0.0595,0.003,0.0265,281.237,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-18",2,1.13,22.6,,0,0.001,15.65,0.06,0.003,0.029,262.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-20",3,1.21,34.98,,0,0.001,21.905,0.059,0.002,0.0287,368.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-21",4,2.42,88.61,,0,0.001,53.435,0.059,0.009,0.041,900.289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-22",3,1.32,36.05,,0,0.001,23.142,0.0593,0.004,0.0243,389.247,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-23",2,1.23,27,,0,0.001,17.931,0.0595,0.003,0.0195,301.131,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-24",4,2.15,67.6,,0,0.001,41.93,0.0595,0.003,0.0318,704.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-25",3,1.37,33.14,,0,0.001,21.469,0.0593,0.015,0.0717,361.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-26",2,1.17,30.87,,0,0.001,19.799,0.0595,0.004,0.025,332.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-27",2,1.22,25.99,,0,0.001,17.313,0.0595,0.003,0.0245,290.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-28",4,2.45,65.9,,0,0.001,41.93,0.059,0.004,0.0173,706.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-29",3,1.2,24.2,,0,0.001,16.55,0.0593,0.002,0.05,278.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-04-30",2,1.28,29.46,,0,0.001,19.338,0.059,0.002,0.0145,325.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-01",8,6.05,260.17,,0.001,0.001,150.611,0.0591,0.013,0.012,2536.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-02",3,1.73,42.39,,0,0.001,27.69,0.0597,0.004,0.0183,465.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-03",2,1.24,52.08,,0,0.001,30.442,0.0595,0.003,0.0125,511.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-04",4,2.1,60.28,,0,0.001,37.74,0.0595,0.006,0.0415,634.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-05",7,4.8,106.95,,0,0.001,69.835,0.0591,0.007,0.0153,1176.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-06",4,2.35,49.35,,0,0.001,32.965,0.0593,0.005,0.0173,554.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-07",5,3.2,70.6,,0,0.001,46.35,0.0592,0.004,0.033,781.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-15",3,1.17,45.4,,0,0.001,26.884,0.0593,0.003,0.0323,452.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-21",6,4.33,91.43,,0,0.001,61.268,0.0592,0.007,0.0228,1031.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-22",4,2.97,108.6,,0,0.001,64.375,0.0593,0.006,0.0173,1082.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-23",2,1.35,47.63,,0,0.001,28.651,0.06,0.004,0.018,481.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-25",3,1.48,41.4,,0,0.001,25.832,0.0597,0.003,0.0283,435.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-26",6,5.2,175,,0.001,0.001,105.96,0.0592,0.008,0.01,1783.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-27",6,4.16,99.92,,0,0.001,64.744,0.0595,0.005,0.0147,1089.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-28",5,3.2,67.69,,0,0.001,45.51,0.0592,0.005,0.038,765.353,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-29",5,3.41,117.59,,0,0.001,71.572,0.0592,0.007,0.0118,1205.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-30",5,3.62,89.48,,0,0.001,57.741,0.0592,0.006,0.0126,972.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-05-31",4,2.34,62.88,,0,0.001,40.335,0.0595,0.005,0.0188,678.297,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-01",5,2.77,61.57,,0,0.001,40.464,0.0592,0.006,0.0348,680.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-02",5,3.53,91.19,,0,0.001,57.779,0.0592,0.004,0.0144,971.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-03",12,8.63,227.75,,0.001,0.001,143.926,0.0592,0.01,0.0206,2423.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-04",5,2.82,58.66,,0,0.001,39.531,0.0594,0.004,0.0196,665.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-06",2,1.22,26.88,,0,0.001,17.89,0.059,0.003,0.016,301.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-08",2,1.24,37.2,,0,0.001,23.126,0.059,0.003,0.017,389.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-09",3,2.12,73.02,,0,0.001,43.121,0.0593,0.003,0.018,724.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-10",4,2.72,89.58,,0,0.001,54.288,0.0593,0.006,0.0148,914.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-11",2,1.2,25.2,,0,0.001,17.1,0.06,0.003,0.0215,286.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-12",2,1.22,25.44,,0,0.001,17.339,0.0595,0.002,0.013,292.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-13",2,1.24,49.1,,0,0.001,29.262,0.059,0.004,0.021,492.903,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-16",2,1.27,35.74,,0,0.001,22.547,0.06,0.003,0.013,378.547,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-17",6,3.44,71.45,,0,0.001,48.652,0.0593,0.007,0.03,818.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-18",6,4.15,88.96,,0,0.001,59.763,0.0593,0.005,0.025,1004.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-19",2,1.15,23,,0,0.001,15.838,0.0595,0.002,0.0255,266.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-20",3,1.72,57.86,,0,0.001,35.341,0.0593,0.004,0.0137,594.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-22",2,1.47,39.84,,0,0.001,25.278,0.0595,0.003,0.0135,424.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-23",2,1.22,25.62,,0,0.001,17.202,0.0595,0.003,0.0235,289.107,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-24",4,1.12,14.08,,0,0.001,11.774,0.059,0.004,0.0638,198.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-26",5,2.96,67.37,,0,0.001,44.109,0.0594,0.004,0.0114,742.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-27",4,3.23,85.89,,0,0.001,54.855,0.0595,0.005,0.0113,923.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-28",3,1.46,44.42,,0,0.001,27.502,0.059,0.004,0.0223,462.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-29",2,1.23,31.8,,0,0.001,20.657,0.059,0.004,0.0235,348.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-06-30",5,3.26,102.17,,0,0.001,62.899,0.0596,0.005,0.0104,1056.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-01",3,1.96,78.32,,0,0.001,46.138,0.0597,0.005,0.0193,775.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-02",2,1.72,66.07,,0,0.001,39.233,0.059,0.004,0.012,660.429,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-03",3,2.51,112.8,,0,0.001,65.217,0.0593,0.006,0.0113,1097.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-04",3,1.95,63.47,,0,0.001,38.924,0.059,0.005,0.0263,655.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-05",6,3.88,125.07,,0,0.001,76.059,0.0597,0.007,0.0107,1278.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-06",3,2.2,87.5,,0,0.001,51.366,0.0593,0.005,0.0117,865.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-07",3,0.94,10.8,,0,0.001,9.44,0.059,0.003,0.0537,159.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-08",1,0.45,0,,0,0.001,2.34,0.059,0.002,0.12,39.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-09",2,0.55,0,,0,0.001,2.888,0.0595,0.002,0.0785,48.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-11",1,0.37,0,,0,0.001,1.887,0.059,0,0.028,31.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-22",2,0.44,0,,0,0.001,2.332,0.0595,0.001,0.028,39.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-25",6,4.08,153.68,,0,0.001,91.798,0.0592,0.007,0.0103,1545.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-26",7,5.77,280.46,,0.001,0.001,161.173,0.059,0.012,0.0109,2713.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-27",2,1.27,27.08,,0,0.001,18.281,0.0595,0.002,0.013,307.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-28",5,3.2,84.6,,0,0.001,53.37,0.0592,0.004,0.0238,898.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-29",5,3.43,110.55,,0,0.001,67.896,0.0594,0.005,0.0126,1142.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-30",5,3.7,139.94,,0,0.001,83.502,0.0598,0.006,0.0364,1402.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-07-31",8,7.08,197.81,,0.001,0.001,123.962,0.0594,0.008,0.0084,2085.554,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-03",2,1.23,28.78,,0,0.001,18.818,0.0595,0.002,0.0165,316.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-05",2,1.17,24.68,,0,0.001,16.722,0.059,0.002,0.018,281.487,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-07",3,1.43,27.84,,0,0.001,19.458,0.0593,0.002,0.0533,327.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-08",3,1.72,39.49,,0,0.001,26.185,0.0593,0.003,0.014,440.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-09",4,2.45,58.13,,0,0.001,38.098,0.0593,0.004,0.013,640.742,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-10",2,1.68,38.66,,0,0.001,25.378,0.059,0.003,0.0115,427.481,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-11",2,1.25,31.29,,0,0.001,20.104,0.059,0.003,0.018,338.559,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-12",4,3.49,114.64,,0,0.001,68.616,0.0595,0.005,0.0083,1153.757,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-13",7,5.39,149.62,,0,0.001,93.636,0.0593,0.007,0.0093,1575.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-14",10,9.02,397.6,,0.001,0.001,228.486,0.0592,0.015,0.0084,3845.791,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-15",8,6.45,308.2,,0.001,0.001,175.735,0.0593,0.011,0.0141,2959.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-16",8,6.53,317.3,,0.001,0.001,180.12,0.059,0.013,0.011,3031.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-17",10,8.72,416.62,,0.001,0.001,236.124,0.0592,0.015,0.0091,3971.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-18",11,9.7,448.4,,0.001,0.001,255.72,0.0591,0.017,0.0083,4303.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-19",13,11.12,463.2,,0.001,0.001,268.269,0.059,0.017,0.0144,4517.379,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-20",9,7.24,347.08,,0.001,0.001,197.624,0.0593,0.012,0.0127,3326.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-21",7,6.15,220.76,,0.001,0.001,131.972,0.0591,0.009,0.0079,2221.214,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-22",5,3.24,68.52,,0,0.001,45.568,0.0594,0.003,0.0196,766.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-23",5,3.47,155.29,,0,0.001,90.669,0.0592,0.006,0.0202,1524.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-24",7,6.17,258.65,,0.001,0.001,150.937,0.0591,0.01,0.0089,2539.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-25",8,5.4,124.55,,0,0.001,81.305,0.0595,0.006,0.0118,1367.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-26",6,4.32,180.42,,0.001,0.001,105.816,0.059,0.008,0.0125,1781.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-27",8,5.24,230.9,,0.001,0.001,133.486,0.0593,0.01,0.0156,2247.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-28",8,6.26,303.38,,0.001,0.001,173.66,0.0593,0.011,0.018,2921.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-29",5,3.3,157.08,,0,0.001,89.655,0.0592,0.006,0.0152,1508.899,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-30",5,3.3,156.68,,0,0.001,89.782,0.0596,0.006,0.0142,1509.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-08-31",5,3.18,67.38,,0,0.001,45.27,0.0594,0.004,0.025,762.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-01",3,1.22,51.68,,0,0.001,30.642,0.0593,0.003,0.0353,515.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-02",3,1.2,23.92,,0,0.001,16.568,0.06,0.002,0.0333,278.276,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-03",5,3.24,153.72,,0,0.001,89.064,0.0592,0.006,0.0194,1497.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-04",8,7.26,287.9,,0.001,0.001,169.976,0.0594,0.011,0.008,2858.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-05",6,5.01,218.79,,0.001,0.001,127.189,0.0593,0.008,0.008,2141.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-06",11,9.8,468.32,,0.001,0.001,268.628,0.0591,0.018,0.0094,4521.454,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-09",4,2.46,78.59,,0,0.001,47.772,0.059,0.006,0.0138,805.191,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-12",3,1.42,28.12,,0,0.001,19.098,0.0597,0.004,0.0533,320.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-13",5,2.64,67.98,,0,0.001,43.467,0.0596,0.005,0.02,730.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-14",4,2.89,124.6,,0,0.001,72.905,0.0593,0.005,0.0118,1227.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-15",6,5,195.45,,0.001,0.001,114.807,0.0597,0.008,0.01,1930.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-16",2,1.25,38.91,,0,0.001,24.232,0.059,0.003,0.015,407.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-17",5,4.47,180.45,,0.001,0.001,105.57,0.0594,0.009,0.011,1775.509,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-18",10,9.72,391.01,,0.001,0.001,227.484,0.0594,0.014,0.0078,3827.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-19",4,3.49,149.54,,0,0.001,85.862,0.0595,0.006,0.0088,1443.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-20",3,1.75,65.8,,0,0.001,38.545,0.0593,0.003,0.036,648.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-21",6,4.24,87.56,,0,0.001,58.514,0.0593,0.006,0.0178,985.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-22",3,1.52,34.9,,0,0.001,23.024,0.0593,0.002,0.0127,388.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-23",5,3.27,155.09,,0,0.001,88.701,0.0596,0.006,0.025,1491.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-24",3,1.33,58.64,,0,0.001,33.783,0.0593,0.004,0.0257,567.927,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-25",3,1.42,52.9,,0,0.001,31.316,0.0593,0.004,0.029,526.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-26",4,2.24,47.06,,0,0.001,31.34,0.059,0.003,0.0215,527.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-27",4,2.3,57.25,,0,0.001,36.385,0.0595,0.003,0.018,610.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-28",6,4.73,154.07,,0,0.001,93.576,0.0592,0.007,0.0113,1573.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-29",7,5.25,204.41,,0.001,0.001,120.272,0.0594,0.008,0.011,2021.769,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-09-30",9,6.65,254.01,,0.001,0.001,149.56,0.0592,0.011,0.0281,2518.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-01",7,5.48,234.07,,0.001,0.001,136.203,0.0594,0.009,0.0161,2290.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-02",8,6.22,142.38,,0,0.001,93.008,0.0594,0.007,0.023,1564.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-03",5,3.18,102.3,,0,0.001,61.734,0.0592,0.005,0.0314,1038.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-04",4,3.14,110.04,,0,0.001,66.095,0.0593,0.006,0.0115,1112.397,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-05",7,6.15,274.9,,0.001,0.001,158.315,0.059,0.012,0.0109,2664.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-06",12,10.41,260.48,,0.001,0.001,167.092,0.0592,0.012,0.0094,2814.433,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-07",2,1.26,30.33,,0,0.001,19.744,0.0595,0.002,0.0125,331.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-08",6,2.95,63.84,,0,0.001,42.63,0.059,0.006,0.0323,718.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-09",3,1.22,45.4,,0,0.001,27.034,0.0593,0.003,0.0273,455.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-10",3,1.25,26.04,,0,0.001,17.692,0.06,0.002,0.0413,296.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-11",2,1.28,29.89,,0,0.001,19.724,0.059,0.003,0.0215,331.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-12",6,5.35,218.79,,0.001,0.001,128.559,0.0593,0.009,0.0097,2162.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-13",6,4.7,112.75,,0,0.001,73.277,0.0592,0.006,0.011,1233.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-19",1,0.7,23.1,,0,0.001,14.07,0.059,0.004,0.032,236.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-20",2,1.28,25.68,,0,0.001,17.568,0.059,0.002,0.0105,295.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-21",4,2.79,62.05,,0,0.001,41.417,0.0598,0.003,0.01,696.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-23",3,1.95,41.85,,0,0.001,28.295,0.0593,0.003,0.012,475.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-24",2,1.23,25.31,,0,0.001,17.293,0.059,0.002,0.012,290.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-25",3,1.42,38.79,,0,0.001,24.852,0.0593,0.002,0.0427,418.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-26",7,4.04,122.5,,0,0.001,75.722,0.0591,0.007,0.0191,1274.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-27",4,2.5,85.43,,0,0.001,52.044,0.0595,0.005,0.011,875.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-28",2,1.22,25.09,,0,0.001,17.286,0.0595,0.002,0.0135,290.552,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-10-31",3,1.68,35.6,,0,0.001,23.888,0.0597,0.003,0.048,401.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-01",3,1.32,26.26,,0,0.001,18.144,0.0597,0.002,0.0233,304.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-02",3,2.26,51.61,,0,0.001,33.938,0.059,0.003,0.0133,572.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-03",2,1.2,27.44,,0,0.001,18.496,0.0595,0.002,0.0105,310.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-04",4,2.95,65.3,,0,0.001,43.336,0.0595,0.004,0.0118,728.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-05",8,5.88,157.59,,0,0.001,99.017,0.0593,0.008,0.0111,1665.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-06",4,2.98,65.91,,0,0.001,43.452,0.0598,0.004,0.0115,730.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-07",3,1.2,27.2,,0,0.001,17.896,0.059,0.004,0.0443,301.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-08",4,2.65,111.5,,0,0.001,65.25,0.0595,0.006,0.0143,1097.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-09",7,5.1,133.93,,0,0.001,85.392,0.0594,0.007,0.0216,1435.671,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-10",4,2.41,76.45,,0,0.001,47.101,0.0593,0.004,0.0095,793.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-11",5,2.28,46.82,,0,0.001,31.874,0.0594,0.004,0.0346,536.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-12",2,1.23,30.59,,0,0.001,19.775,0.059,0.002,0.0105,333.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-13",5,2.82,91.71,,0,0.001,56.455,0.0594,0.006,0.0154,949.949,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-14",2,0.85,16.05,,0,0.001,11.415,0.06,0.003,0.0235,191.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-24",4,3.43,132.39,,0,0.001,86.891,0.059,0.007,0.0105,1463.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-11-30",7,6.09,289.73,,0.001,0.001,189,0.0593,0.018,0.0107,3178.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-01",4,2.42,53.82,,0,0.001,36.969,0.0595,0.004,0.014,621.671,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-02",5,3.17,70.52,,0,0.001,48.481,0.0598,0.005,0.0136,814.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-03",6,4.52,117.56,,0,0.001,78.998,0.0595,0.007,0.0128,1329.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-04",4,3,75.68,,0,0.001,52.475,0.0593,0.005,0.012,882.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-05",2,1.5,34.8,,0,0.001,23.73,0.0595,0.003,0.012,399.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-06",5,2.62,60.12,,0,0.001,41.059,0.0592,0.005,0.0204,691.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-07",5,2.68,54.16,,0,0.001,36.671,0.0594,0.005,0.0204,616.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-08",5,2.46,72.2,,0,0.001,48.474,0.0592,0.004,0.0238,814.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-09",10,7.59,208.6,,0.001,0.001,135.172,0.0595,0.012,0.0139,2273.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-10",5,2.46,63.1,,0,0.001,41.956,0.059,0.005,0.0242,706.978,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-11",9,7.61,286.2,,0.001,0.001,179.886,0.0592,0.014,0.0151,3025.458,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-12",6,4.17,150.64,,0,0.001,96.271,0.059,0.008,0.0125,1620.633,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-14",5,2.65,55.29,,0,0.001,38.272,0.0592,0.004,0.0292,644.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-15",16,11.74,498.38,,0.002,0.001,313.195,0.0592,0.023,0.0141,5270.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-16",7,6.18,190.57,,0.001,0.001,125.512,0.0593,0.011,0.0106,2113.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-18",2,1.42,35.52,,0,0.001,24.151,0.059,0.003,0.0155,406.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-19",3,1.22,26.94,,0,0.001,18.914,0.059,0.003,0.0417,318.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-22",5,4.2,184.68,,0.001,0.001,114.252,0.059,0.01,0.0116,1922.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-23",2,1.2,23.88,,0,0.001,16.74,0.059,0.002,0.015,282.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-27",5,2.85,57.19,,0,0.001,40.116,0.0596,0.004,0.017,674.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-28",8,6.7,284.89,,0.001,0.001,180.389,0.0591,0.014,0.0114,3036.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-29",2,1.2,31.71,,0,0.001,21.645,0.059,0.003,0.015,364.371,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"3",,"2020-12-31",2,1.22,24.4,,0,0.001,16.995,0.059,0.003,0.029,286.242,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-14",2,1.23,25.9,,0,0.001,17.812,0.06,0.003,0.0205,299.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-17",5,2.62,96.05,,0,0.001,56.833,0.059,0.005,0.022,957.067,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-18",3,1.3,39.84,,0,0.001,24.756,0.0593,0.003,0.0287,417.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-21",2,1.24,32.89,,0,0.001,21.429,0.0595,0.003,0.0135,360.001,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-23",4,2.24,79.56,,0,0.001,47.552,0.0593,0.004,0.024,800.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-25",3,1.4,29,,0,0.001,19.86,0.0597,0.003,0.0317,334.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-28",5,2.47,80.65,,0,0.001,49.537,0.0592,0.005,0.024,832.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-30",5,2.46,99.36,,0,0.001,57.904,0.0592,0.006,0.0336,974.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-01-31",6,4.19,145.04,,0,0.001,87.524,0.0593,0.008,0.0265,1471.182,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-02",3,1.45,29.12,,0,0.001,20.263,0.0597,0.002,0.0433,340.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-03",5,2.44,54.61,,0,0.001,36.447,0.0594,0.005,0.0286,612.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-04",5,2.44,58.09,,0,0.001,38.5,0.059,0.006,0.0352,647.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-05",3,1.95,62.45,,0,0.001,38.06,0.0593,0.006,0.0303,641.295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-08",3,1.7,38.75,,0,0.001,25.535,0.059,0.003,0.0187,430.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-10",2,1.16,22.87,,0,0.001,15.909,0.059,0.003,0.0295,267.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-11",3,1.23,30.68,,0,0.001,19.876,0.0593,0.003,0.0363,334.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-12",2,1.2,23.4,,0,0.001,16.32,0.059,0.003,0.021,274.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-13",6,2.92,59.77,,0,0.001,41.38,0.0593,0.005,0.0312,696.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-14",4,2.45,67.57,,0,0.001,43.012,0.0595,0.006,0.0143,722.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-15",2,1.2,24.65,,0,0.001,17.28,0.0595,0.002,0.0155,290.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-16",3,1.28,26.88,,0,0.001,18.408,0.0597,0.002,0.026,309.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-17",2,0.99,24.86,,0,0.001,16.096,0.06,0.002,0.0345,270.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-18",2,1.22,33.39,,0,0.001,21.268,0.059,0.004,0.0215,358.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-19",2,1.31,34.45,,0,0.001,21.939,0.059,0.002,0.012,369.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-20",2,1.47,29.67,,0,0.001,20.628,0.0595,0.003,0.0145,346.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-21",2,1.12,22.13,,0,0.001,15.321,0.0595,0.002,0.024,257.858,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-23",3,1.98,40.4,,0,0.001,27.965,0.0593,0.003,0.033,470.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-24",2,1.75,39.5,,0,0.001,26.66,0.06,0.002,0.0105,447.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-25",2,1.25,28.35,,0,0.001,18.883,0.0595,0.003,0.0235,318.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-26",3,2.29,62.49,,0,0.001,39.661,0.0597,0.004,0.0117,666.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-27",2,1.2,24,,0,0.001,16.56,0.059,0.003,0.0185,279.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-01",4,3.07,77.98,,0,0.001,50.362,0.0595,0.003,0.0088,846.791,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-02",5,3.49,90.05,,0,0.001,57.868,0.0596,0.007,0.0166,972.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-03",6,3.25,80.9,,0,0.001,52.135,0.0592,0.006,0.0312,877.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-05",2,1.5,35.52,,0,0.001,23.042,0.059,0.003,0.015,388.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-06",4,2.52,54.56,,0,0.001,36.726,0.0593,0.006,0.0295,618.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-08",2,1.45,32.4,,0,0.001,21.83,0.0595,0.003,0.014,367.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-09",4,2.88,65.35,,0,0.001,43.833,0.059,0.005,0.0193,739.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-10",5,2.72,64.14,,0,0.001,42.502,0.059,0.005,0.0202,716.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-11",6,3.95,104.91,,0,0.001,67.541,0.0595,0.006,0.0208,1136.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-12",8,5.71,225.5,,0.001,0.001,133.131,0.0591,0.011,0.0171,2241.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-13",5,3.47,124.76,,0,0.001,75.432,0.0592,0.007,0.0114,1269.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-14",4,2.4,81.3,,0,0.001,49.527,0.0593,0.005,0.016,833.642,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-15",10,8,327.94,,0.001,0.001,192.453,0.0595,0.013,0.0104,3234.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-16",6,4.4,164.39,,0,0.001,97.453,0.059,0.009,0.0125,1639.503,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-17",3,1.2,23.92,,0,0.001,16.424,0.0593,0.002,0.0397,276.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-18",4,3.12,65.8,,0,0.001,44.956,0.0593,0.004,0.023,756.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-19",2,1.22,23.8,,0,0.001,16.718,0.0595,0.003,0.0205,281.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-20",4,2.32,45.15,,0,0.001,31.688,0.0593,0.004,0.0153,532.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-21",4,2.96,62.84,,0,0.001,42.797,0.0593,0.004,0.0123,720.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-22",2,1.49,33.15,,0,0.001,22.118,0.06,0.003,0.018,371.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-23",4,2.53,53.97,,0,0.001,36.833,0.0598,0.004,0.0135,618.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-24",5,2.55,80.02,,0,0.001,49.744,0.0592,0.005,0.0218,838.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-26",4,3.02,67.58,,0,0.001,45.502,0.0595,0.004,0.012,764.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-28",3,1.62,44.2,,0,0.001,28.064,0.0597,0.004,0.024,471.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-30",5,3.13,65.52,,0,0.001,44.517,0.0596,0.005,0.0148,748.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-01",5,2.47,75.22,,0,0.001,46.642,0.0594,0.005,0.0334,784.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-02",5,2.42,48.2,,0,0.001,33.279,0.059,0.003,0.0202,560.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-04",2,1.47,52,,0,0.001,31.145,0.059,0.006,0.0225,523.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-05",15,13.58,540.41,,0.002,0.001,314.733,0.0593,0.021,0.0086,5294.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-06",6,3.75,143.59,,0,0.001,84.676,0.0593,0.007,0.0193,1424.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-07",5,3.2,86.56,,0,0.001,54.955,0.059,0.007,0.023,925.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-08",6,2.5,84.86,,0,0.001,51.07,0.0592,0.006,0.0303,858.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-09",10,7.12,306.92,,0.001,0.001,177.592,0.0594,0.015,0.0123,2987.144,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-12",3,1.48,29.9,,0,0.001,20.594,0.0593,0.003,0.0293,346.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-14",3,1.95,40.38,,0,0.001,27.5,0.0593,0.003,0.0203,462.569,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-16",9,7.97,384.48,,0.001,0.001,218.672,0.059,0.016,0.024,3681.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-17",2,1.22,24.77,,0,0.001,16.825,0.059,0.003,0.028,283.581,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-18",2,1.13,21.76,,0,0.001,15.23,0.059,0.002,0.028,256.989,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-21",3,1.47,38.4,,0,0.001,25.111,0.0597,0.004,0.0293,421.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-22",4,2.46,60.31,,0,0.001,39.702,0.0593,0.005,0.0168,668.922,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-23",2,1.21,26.1,,0,0.001,17.61,0.059,0.003,0.024,296.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-24",4,2.15,65.5,,0,0.001,40.995,0.0593,0.003,0.033,689.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-25",2,1.15,22.99,,0,0.001,15.98,0.0595,0.002,0.016,268.793,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-26",2,1.17,30.87,,0,0.001,19.963,0.0595,0.003,0.0225,335.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-27",2,1.22,25.62,,0,0.001,17.409,0.0595,0.002,0.021,292.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-28",3,1.68,46.81,,0,0.001,29.895,0.059,0.004,0.0167,503.329,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-29",3,1.18,23.62,,0,0.001,16.528,0.0597,0.002,0.0353,278.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-04-30",2,1.28,28.61,,0,0.001,19.296,0.06,0.002,0.015,323.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-01",8,6.02,253.08,,0.001,0.001,146.512,0.0593,0.012,0.0114,2465.847,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-02",3,1.48,37.5,,0,0.001,24.5,0.0593,0.003,0.023,411.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-03",2,1.24,49.6,,0,0.001,28.83,0.059,0.003,0.0135,485.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-04",3,2.22,68.44,,0,0.001,41.598,0.059,0.004,0.0127,701.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-05",5,3.5,76.35,,0,0.001,51.27,0.0594,0.004,0.015,862.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-06",2,1.2,25.8,,0,0.001,17.22,0.059,0.003,0.019,290.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-07",5,3.2,67.3,,0,0.001,45.6,0.059,0.004,0.035,769.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-08",4,2.4,50.4,,0,0.001,33.908,0.059,0.003,0.0193,571,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-15",5,1.72,40.08,,0,0.001,38.094,0.0592,0.004,0.0246,640.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-18",2,1.45,49.69,,0,0.001,29.713,0.059,0.005,0.0175,500.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-21",6,4.33,90.41,,0,0.001,61.632,0.0593,0.006,0.018,1036.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-22",4,2.97,103.8,,0,0.001,61.909,0.0595,0.005,0.0153,1041.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-23",2,1.09,22.07,,0,0.001,15.314,0.0595,0.002,0.023,257.339,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-24",5,2.45,61.05,,0,0.001,40.429,0.0594,0.005,0.0286,680.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-25",4,2.98,134.22,,0,0.001,77.004,0.0595,0.006,0.0105,1295.509,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-26",6,5.2,169.8,,0.001,0.001,103.74,0.0595,0.008,0.0097,1744.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-27",6,4.16,98.16,,0,0.001,64.713,0.0593,0.006,0.0155,1089.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-28",3,1.2,23.95,,0,0.001,16.54,0.059,0.002,0.035,278.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-29",4,2.71,107.72,,0,0.001,63.852,0.0593,0.006,0.0135,1074.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-30",4,2.28,67.28,,0,0.0008,41.792,0.059,0.023,0.0455,704.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-05-31",4,2.34,50.1,,0,0.001,34.226,0.0598,0.004,0.0168,575.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-01",5,2.75,60.54,,0,0.001,40.582,0.0592,0.005,0.0232,682.871,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-02",5,3.55,91.53,,0,0.001,57.61,0.059,0.004,0.0124,971.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-03",12,8.65,221.88,,0.001,0.001,141.962,0.059,0.009,0.0167,2390.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-04",5,2.82,59.43,,0,0.001,40.469,0.0594,0.003,0.0148,680.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-08",2,1.24,36.58,,0,0.001,22.878,0.0595,0.003,0.0165,385.144,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-09",3,2.47,79.76,,0,0.001,47.755,0.0593,0.003,0.011,804.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-10",4,2.72,86.34,,0,0.001,52.758,0.059,0.006,0.0185,888.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-11",2,1.2,24,,0,0.001,16.8,0.0595,0.003,0.019,282.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-12",2,1.22,24.22,,0,0.001,17.147,0.059,0.002,0.0125,288.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-16",2,1.24,30.93,,0,0.001,20.08,0.059,0.003,0.0145,337.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-17",4,2.18,46.26,,0,0.001,31.838,0.0598,0.003,0.0385,534.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-18",3,1.16,23.4,,0,0.001,16.168,0.0593,0.002,0.0513,272.488,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-19",6,4.66,104.16,,0,0.001,70.328,0.0593,0.005,0.0247,1182.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-20",2,1.18,28.93,,0,0.001,19.089,0.06,0.002,0.011,320.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-22",2,1.47,38.1,,0,0.001,24.468,0.0595,0.003,0.013,410.991,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-23",2,1.22,22.81,,0,0.001,16.418,0.0595,0.002,0.0245,275.927,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-24",3,1.47,29.7,,0,0.001,20.797,0.06,0.002,0.0193,349.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-26",5,2.96,64.96,,0,0.001,43.622,0.0594,0.004,0.0112,733.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-27",4,3.23,85.94,,0,0.001,54.644,0.059,0.005,0.011,919.821,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-28",3,1.46,42.14,,0,0.001,26.478,0.0597,0.004,0.023,444.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-29",2,1.23,31,,0,0.001,20.257,0.059,0.004,0.0265,341.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-06-30",4,2.95,101.9,,0,0.001,61.66,0.0593,0.006,0.016,1037.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-01",3,1.98,77.83,,0,0.001,45.78,0.06,0.006,0.021,769.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-02",2,1.72,65.22,,0,0.001,38.804,0.0595,0.004,0.012,652.723,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-03",3,2.51,107.29,,0,0.001,61.79,0.059,0.006,0.0117,1040.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-04",3,1.93,68.03,,0,0.001,40.788,0.0593,0.004,0.0157,686.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-05",6,3.88,121.88,,0,0.001,74.615,0.059,0.006,0.0115,1255.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-06",3,2.2,85.26,,0,0.001,50.18,0.059,0.005,0.0137,844.698,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-07",3,1.94,55.3,,0,0.001,34.788,0.0593,0.004,0.019,585.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-08",2,1.2,24.42,,0,0.001,16.881,0.06,0.002,0.014,283.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-09",4,2.19,53.88,,0,0.001,34.843,0.0593,0.003,0.0268,587.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-10",6,4.73,217.62,,0.001,0.001,124.524,0.059,0.009,0.012,2095.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-11",6,5.27,224.07,,0.001,0.001,128.851,0.059,0.009,0.0095,2170.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-12",6,4.69,211.12,,0.001,0.001,121.256,0.0592,0.01,0.015,2040.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-13",5,3.25,151.61,,0,0.001,86.224,0.059,0.006,0.0188,1451.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-14",3,1.22,25.7,,0,0.001,17.306,0.059,0.002,0.0283,291.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-15",2,1.27,28.77,,0,0.001,18.957,0.059,0.003,0.0205,319.773,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-18",3,1.53,62.95,,0,0.001,36.863,0.06,0.004,0.0167,619.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-21",4,2.47,63.52,,0,0.001,40.912,0.0598,0.005,0.0205,687.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-22",3,1.72,42.16,,0,0.001,27.549,0.06,0.003,0.0127,462.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-24",3,1.97,42.44,,0,0.001,28.843,0.06,0.003,0.0163,484.221,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-25",3,2.48,87.88,,0,0.001,52.368,0.059,0.005,0.011,881.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-26",3,2.72,106.67,,0,0.001,62.364,0.059,0.005,0.0093,1049.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-30",5,3.98,155.5,,0,0.001,91.339,0.0592,0.008,0.014,1536.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-07-31",8,7.3,204.8,,0.001,0.001,128.325,0.0591,0.009,0.0088,2159.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-01",3,1.38,27.5,,0,0.001,19.252,0.0593,0.002,0.036,323.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-02",4,2.2,47.3,,0,0.001,32.16,0.0595,0.003,0.033,540.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-03",7,4.43,97.56,,0,0.001,65.456,0.0594,0.006,0.0151,1100.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-05",2,0.6,10.02,,0,0.001,7.585,0.0595,0.002,0.034,127.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-07",3,1.43,34.35,,0,0.001,22.827,0.0593,0.002,0.0473,384.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-08",3,1.72,39.11,,0,0.001,25.963,0.0597,0.003,0.0147,436.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-09",3,2.18,53.72,,0,0.001,34.86,0.0593,0.004,0.0177,585.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-10",2,1.43,32,,0,0.001,21.291,0.0595,0.002,0.011,357.951,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-12",4,3.48,102,,0,0.001,63.068,0.059,0.005,0.0088,1063.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-13",7,5.07,135.72,,0,0.001,85.378,0.0593,0.007,0.0136,1437.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-14",10,9.01,390.9,,0.001,0.001,222.735,0.059,0.014,0.0099,3750.981,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-15",8,6.45,301.9,,0.001,0.001,171.1,0.0595,0.011,0.0155,2876.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-16",8,6.53,311.36,,0.001,0.001,176.018,0.0591,0.012,0.0098,2962.018,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-17",10,8.75,408.67,,0.001,0.001,230.067,0.0591,0.015,0.009,3871.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-18",11,9.45,429.05,,0.001,0.001,243.205,0.059,0.018,0.0129,4093.035,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-19",13,11.13,456.25,,0.001,0.001,263.856,0.0593,0.017,0.0148,4439.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-20",9,7.25,343.82,,0.001,0.001,194.026,0.059,0.012,0.0116,3264.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-21",3,2.38,62.84,,0,0.001,40.09,0.0593,0.004,0.0123,674.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-22",5,3.25,71.72,,0,0.001,48.038,0.059,0.003,0.017,809.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-23",2,1.47,36.09,,0,0.001,23.55,0.0595,0.003,0.0135,395.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-24",7,6.43,201.52,,0.001,0.001,123.516,0.0591,0.009,0.0084,2079.869,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-25",5,3.67,83.99,,0,0.001,54.914,0.0592,0.005,0.011,925.139,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-26",4,2.97,65.64,,0,0.001,44.006,0.0595,0.004,0.011,739.472,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-27",8,5.49,179.31,,0.001,0.001,108.411,0.0593,0.01,0.0154,1825.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-28",5,3.24,151.08,,0,0.001,85.672,0.0592,0.006,0.0216,1441.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-29",5,3.35,155.38,,0,0.001,88.447,0.0592,0.007,0.0172,1487.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-30",5,3.3,154.08,,0,0.001,87.434,0.0592,0.006,0.0158,1471.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-08-31",5,3.18,67.08,,0,0.001,45.932,0.0594,0.004,0.0308,772.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-01",3,1.22,52.52,,0,0.001,30.388,0.0597,0.003,0.023,510.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-02",3,1.2,24,,0,0.001,16.78,0.059,0.002,0.0353,282.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-03",2,1.2,24.6,,0,0.001,16.98,0.06,0.002,0.0165,285.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-04",7,6.23,277.42,,0.001,0.001,158.697,0.059,0.01,0.0081,2671.858,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-05",10,8.36,374.8,,0.001,0.001,215.508,0.0594,0.014,0.0112,3624.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-06",11,9.82,461.5,,0.001,0.001,261.724,0.0593,0.017,0.0088,4400.978,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-12",3,1.39,29.14,,0,0.001,19.841,0.06,0.003,0.0487,332.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-13",5,2.64,68.64,,0,0.001,44.137,0.0594,0.005,0.0214,742.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-14",4,2.69,114.98,,0,0.001,66.393,0.0595,0.006,0.0158,1116.454,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-15",6,5,193.84,,0.001,0.001,113.528,0.0595,0.008,0.0093,1908.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-16",2,1.24,33.61,,0,0.001,21.343,0.059,0.003,0.0135,359.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-17",6,4.72,184.34,,0.001,0.001,107.816,0.0593,0.01,0.0153,1814.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-18",10,9.72,384.86,,0.001,0.001,222.496,0.0593,0.015,0.0083,3741.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-19",4,3.49,146.05,,0,0.001,83.702,0.0595,0.007,0.0103,1408.463,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-20",3,1.77,66.52,,0,0.001,38.537,0.0593,0.003,0.0327,649.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-21",6,4.22,93,,0,0.001,61.922,0.0593,0.006,0.0163,1042.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-22",3,1.52,36,,0,0.001,23.644,0.0593,0.003,0.0207,398.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-23",5,3.27,152.17,,0,0.001,86.32,0.059,0.006,0.0294,1452.247,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-24",3,1.35,58.33,,0,0.001,33.355,0.059,0.003,0.0203,561.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-25",3,1.43,52.52,,0,0.001,31.298,0.059,0.003,0.0233,527.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-26",4,2.28,103.4,,0,0.001,58.924,0.0593,0.005,0.0193,990.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-27",4,2.3,102.75,,0,0.001,58.49,0.059,0.005,0.018,983.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-28",5,4.13,138.45,,0,0.001,82.877,0.0594,0.007,0.0156,1394.473,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-29",5,3.69,129.34,,0,0.001,76.975,0.0592,0.006,0.0126,1296.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-09-30",6,4.2,91.88,,0,0.001,61.246,0.059,0.006,0.0118,1031.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-01",5,3.4,87.21,,0,0.001,55.694,0.0596,0.007,0.0184,935.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-02",4,2.46,53.61,,0,0.001,35.841,0.0595,0.005,0.018,602.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-03",5,3.18,99.3,,0,0.001,60.354,0.0596,0.005,0.0262,1015.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-04",4,2.94,99.13,,0,0.001,59.521,0.0593,0.007,0.0183,1001.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-05",7,6.17,274.09,,0.001,0.001,156.846,0.0596,0.012,0.0109,2636.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-06",12,10.42,258,,0.001,0.001,167.982,0.0594,0.012,0.0096,2825.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-07",2,1.25,29.61,,0,0.001,19.555,0.0595,0.002,0.013,328.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-08",8,4.4,99.05,,0,0.001,66.07,0.0591,0.008,0.0254,1112.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-09",3,1.22,44.88,,0,0.001,26.898,0.0593,0.003,0.026,452.566,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-10",5,2.46,51.52,,0,0.001,35.2,0.0594,0.004,0.0216,591.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-11",7,5.12,116.3,,0,0.0009,77.494,0.0594,0.005,0.0084,1303.486,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-12",6,5.33,216.43,,0.001,0.001,126.619,0.0593,0.009,0.0087,2129.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-13",6,4.94,119.62,,0,0.001,78.087,0.0595,0.006,0.0132,1312.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-14",6,4.99,177.57,,0.001,0.001,106.559,0.059,0.009,0.0127,1794.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-15",4,3.44,95.02,,0,0.001,60.295,0.0593,0.005,0.0103,1015.591,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-16",6,4.19,93.44,,0,0.001,62.207,0.0593,0.005,0.0285,1048.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-17",2,1.22,24.99,,0,0.001,17.279,0.0595,0.002,0.0145,290.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-19",2,1.28,25.68,,0,0.001,17.944,0.059,0.002,0.0135,302.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-20",3,2.02,45.74,,0,0.001,30.502,0.059,0.003,0.011,514.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-21",4,3.02,92.74,,0,0.001,57.482,0.0593,0.004,0.01,966.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-23",3,1.95,43.7,,0,0.001,29.105,0.059,0.002,0.0137,490.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-24",2,1.25,26.02,,0,0.001,17.871,0.06,0.002,0.012,300.219,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-25",5,2.67,75.33,,0,0.001,47.627,0.0594,0.005,0.0328,801.236,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-26",7,4.04,121.82,,0,0.001,75.504,0.0591,0.008,0.0239,1270.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-27",5,3.02,102.52,,0,0.001,61.526,0.059,0.008,0.013,1035.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-28",2,1.22,25.09,,0,0.001,17.565,0.06,0.003,0.0165,295.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-29",2,1.25,26.85,,0,0.001,18.414,0.059,0.002,0.014,310.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-10-31",3,1.66,35.72,,0,0.001,24.142,0.0593,0.003,0.0453,406.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-01",2,1.28,25.48,,0,0.001,17.895,0.059,0.002,0.0135,301.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-02",3,2.27,51.35,,0,0.001,34.3,0.0593,0.004,0.0203,577.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-03",2,1.19,28.06,,0,0.001,18.442,0.059,0.002,0.012,311.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-04",4,2.95,65.25,,0,0.001,43.743,0.0595,0.004,0.0125,736.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-05",8,5.85,163.72,,0.001,0.001,102.695,0.059,0.01,0.0133,1729.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-06",4,2.97,65.74,,0,0.001,43.954,0.0593,0.004,0.0115,738.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-07",3,1.2,27.44,,0,0.001,18.2,0.0597,0.004,0.0493,305.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-08",2,1.08,30.75,,0,0.001,19.271,0.059,0.003,0.0245,325.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-09",8,4.93,129.54,,0,0.001,82.79,0.0591,0.007,0.0204,1394.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-10",4,2.63,80.83,,0,0.001,49.853,0.0593,0.006,0.0125,839.749,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-11",5,2.28,46.82,,0,0.001,32.25,0.059,0.004,0.043,543.778,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-12",2,1.23,30.59,,0,0.001,19.722,0.059,0.003,0.014,332.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-13",2,1.45,31.07,,0,0.001,20.921,0.06,0.003,0.018,351.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-14",2,0.73,11.34,,0,0.001,8.786,0.06,0.004,0.12,147.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-24",3,2.07,82.08,,0,0.001,48.567,0.0593,0.006,0.0163,817.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-01",5,2.65,60.19,,0,0.001,40.516,0.0592,0.005,0.0288,682.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-02",3,1.68,41,,0,0.001,27.1,0.059,0.003,0.047,455.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-03",6,4.25,104.15,,0,0.001,68.845,0.059,0.006,0.02,1159.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-04",4,3.27,82.51,,0,0.001,54.124,0.0595,0.006,0.0133,910.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-05",3,1.68,34.22,,0,0.001,23.597,0.0597,0.004,0.0263,396.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-06",3,1.45,29.2,,0,0.001,20.187,0.059,0.004,0.0307,340.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-07",5,2.67,53.22,,0,0.001,36.879,0.0598,0.005,0.0204,620.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-08",5,2.46,71.1,,0,0.001,44.244,0.059,0.005,0.0196,745.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-09",4,2.42,56.84,,0,0.001,37.266,0.059,0.006,0.0255,626.634,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-10",11,7.05,195.32,,0.001,0.001,123.11,0.0593,0.011,0.0272,2072.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-11",8,5.37,217.41,,0.001,0.001,127.154,0.0593,0.009,0.0219,2139.773,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-12",7,4.96,206.73,,0.001,0.001,120.882,0.0593,0.011,0.013,2035.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-14",5,2.65,56.01,,0,0.001,38.446,0.0598,0.004,0.0212,646.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-15",5,2.52,76.11,,0,0.001,47.513,0.0594,0.004,0.0184,799.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-16",8,7.03,210.88,,0.001,0.001,130.55,0.0594,0.012,0.0118,2196.181,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-18",3,1.92,52.22,,0,0.001,33.541,0.059,0.005,0.017,564.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-19",6,2.49,52.56,,0,0.001,36.3,0.0595,0.004,0.0338,611.009,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-22",6,5.2,233.68,,0.001,0.001,134.73,0.0592,0.012,0.0117,2266.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-23",3,1.45,39.99,,0,0.001,25.643,0.06,0.005,0.0293,430.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-27",3,1.4,28.4,,0,0.001,19.484,0.0597,0.002,0.026,327.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-28",9,6.92,297.22,,0.001,0.001,172.128,0.059,0.013,0.0168,2897.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Riverside Energy Resource Center",56143,"4",,"2020-12-31",2,1.24,24.43,,0,0.001,16.914,0.059,0.003,0.034,284.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-03",4,3.21,133.69,,0,0.001,78.183,0.059,0.017,0.0258,1315.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-06",14,12.53,545.06,,0.002,0.001,316.925,0.0591,0.028,0.0217,5335.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-07",4,2.2,89.86,,0,0.001,53.202,0.059,0.012,0.0865,894.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-08",3,2.18,88.46,,0,0.001,52.136,0.0597,0.015,0.0313,876.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-09",3,2.2,89,,0,0.001,52.31,0.0597,0.015,0.0307,879.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-10",9,7.25,305.26,,0.001,0.001,177.777,0.059,0.029,0.0249,2992.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-14",9,8.19,353.28,,0.001,0.001,204.61,0.0592,0.036,0.0218,3442.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-17",4,2.92,121.92,,0,0.001,71.136,0.0593,0.012,0.0333,1196.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-20",9,6.4,267.81,,0.001,0.001,156.574,0.0591,0.027,0.0447,2636.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-23",18,17.19,751.01,,0.002,0.001,436.478,0.0593,0.036,0.0106,7343.917,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-27",8,7.2,309.69,,0.001,0.001,180.22,0.0593,0.02,0.014,3032.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-30",5,3.85,159.62,,0,0.001,92.967,0.059,0.027,0.04,1565.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-01-31",5,3.48,141.72,,0,0.001,83.048,0.0598,0.013,0.022,1395.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-03",7,4.76,205.15,,0.001,0.001,118.742,0.0591,0.027,0.0756,1998.173,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-04",6,4.13,167.41,,0,0.001,98.475,0.0592,0.026,0.0423,1658.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-06",7,6.75,294,,0.001,0.001,170.95,0.0593,0.017,0.014,2875.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-07",2,1.53,62.55,,0,0.001,36.789,0.059,0.002,0.0075,619.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-14",9,7.44,312.71,,0.001,0.001,182.411,0.0592,0.029,0.0206,3069.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-15",1,0.12,0,,0,0.001,0.66,0.06,0.001,0.197,11.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-21",2,1.15,41.86,,0,0.001,25.231,0.059,0.011,0.1255,424.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-23",4,3.25,135.05,,0,0.001,80.115,0.0593,0.012,0.0293,1347.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-24",17,14.17,609.17,,0.002,0.001,358.138,0.0592,0.031,0.0276,6027.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-25",19,16.37,701.56,,0.002,0.001,411.94,0.0592,0.05,0.0178,6933.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-26",15,12.31,516.32,,0.002,0.001,301.758,0.0592,0.055,0.0239,5077.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-27",20,17.73,769.82,,0.002,0.001,449.468,0.0592,0.033,0.0231,7561.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-28",18,16.71,728.03,,0.002,0.001,424.267,0.0593,0.026,0.0111,7139.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-01",4,2.66,109.55,,0,0.001,64.575,0.0598,0.012,0.0898,1085.179,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-02",11,9.93,429.2,,0.001,0.001,250.394,0.0593,0.025,0.0143,4215.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-03",6,5.92,256.8,,0.001,0.001,149.104,0.0592,0.018,0.0157,2509.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-04",6,4.49,184.6,,0.001,0.001,108.842,0.0595,0.016,0.0175,1830.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-05",5,4.72,199.2,,0.001,0.001,116.344,0.0592,0.016,0.0172,1957.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-06",8,7.67,334.13,,0.001,0.001,196.177,0.059,0.016,0.0126,3301.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-07",1,0.28,7.56,,0,0.001,5.068,0.059,0.001,0.018,85.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-09",12,10.44,442.08,,0.001,0.001,260.278,0.0591,0.034,0.0353,4380.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-10",13,10.18,425.32,,0.001,0.001,252.958,0.0592,0.038,0.0211,4256.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-11",6,5.9,255,,0.001,0.001,149.62,0.059,0.017,0.015,2518.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-12",6,4.45,187.39,,0.001,0.001,111.146,0.0593,0.017,0.017,1869.439,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-13",8,7.28,313.4,,0.001,0.001,184.476,0.0593,0.017,0.0115,3102.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-16",9,8.2,353.9,,0.001,0.001,207.07,0.0594,0.026,0.016,3482.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-17",18,16.9,733.92,,0.002,0.001,427.18,0.0592,0.048,0.015,7189.542,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-18",4,2.5,97.4,,0,0.001,58.36,0.0595,0.012,0.0383,981.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-20",16,14.6,634.68,,0.002,0.001,372.884,0.0593,0.03,0.0166,6271.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-22",6,4.37,184.98,,0.001,0.001,108.481,0.0593,0.018,0.0345,1825.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-26",8,6.92,296.68,,0.001,0.001,173.924,0.0593,0.022,0.0501,2926.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-27",16,15.2,660.4,,0.002,0.001,386.11,0.0592,0.037,0.0126,6497.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-29",7,5.68,242.08,,0.001,0.001,141.413,0.0593,0.018,0.0506,2379.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-03",5,4.22,177.2,,0.001,0.001,104.448,0.0592,0.02,0.0234,1757.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-04",5,3.48,142.44,,0,0.001,84.458,0.0592,0.014,0.0592,1422.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-05",4,2.2,87.42,,0,0.001,51.618,0.0595,0.012,0.0823,869.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-06",3,2.22,88.5,,0,0.001,52.462,0.059,0.016,0.033,883.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-13",7,5.34,221.28,,0.001,0.001,130.136,0.0591,0.019,0.0153,2190.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-14",6,4.9,203,,0.001,0.001,119.496,0.0597,0.015,0.0207,2008.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-15",6,4.78,199.2,,0.001,0.001,117.598,0.0595,0.017,0.0245,1979.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-21",4,2.33,89.34,,0,0.001,54.133,0.0593,0.016,0.089,911.454,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-22",9,7.25,299.8,,0.001,0.001,177.91,0.0591,0.023,0.0179,2994.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-23",6,5.63,238.94,,0.001,0.001,140.701,0.0592,0.015,0.0168,2366.871,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-24",10,8.54,354.84,,0.001,0.001,209.964,0.0591,0.019,0.012,3533.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-25",3,2.2,87.4,,0,0.001,52.4,0.0597,0.014,0.0293,880.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-27",21,19.55,829.85,,0.002,0.001,491.635,0.0592,0.05,0.0168,8269.825,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-28",8,6.54,269.02,,0.001,0.001,160.312,0.0591,0.03,0.0278,2699.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-01",3,2.22,87.06,,0,0.001,52.058,0.0597,0.015,0.0307,874.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-05",7,6.7,279.7,,0.001,0.001,164.97,0.0593,0.02,0.0153,2775.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-08",4,2.2,86.55,,0,0.001,51.355,0.059,0.011,0.0803,864.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-09",3,2.48,99.45,,0,0.001,58.267,0.0593,0.014,0.0277,979.488,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-26",3,2.22,86.98,,0,0.001,52.328,0.0593,0.014,0.0287,879.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-27",4,2.21,86.95,,0,0.001,52.271,0.0595,0.011,0.0918,879.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-28",4,1.32,0,,0,0.001,6.951,0.0595,0.013,0.2203,117.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-30",5,3.99,164.07,,0,0.001,97.378,0.059,0.014,0.0654,1639.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-08",3,2.38,94.62,,0,0.001,56.408,0.0593,0.014,0.0293,949.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-09",7,5.57,231.44,,0.001,0.001,135.431,0.0591,0.017,0.0531,2280.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-10",9,7.43,302.83,,0.001,0.001,179.227,0.0596,0.025,0.0238,3013.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-05",4,2.18,86.73,,0,0.001,51.942,0.0598,0.011,0.079,873.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-06",3,2.2,87.48,,0,0.001,52.248,0.0593,0.013,0.0283,878.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-09",5,3.51,142.71,,0,0.001,85.325,0.0592,0.012,0.0566,1435.789,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-10",3,2.55,102.63,,0,0.001,61.797,0.0597,0.012,0.0253,1038.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-11",9,7.45,316.7,,0.001,0.001,187.97,0.0592,0.018,0.0351,3162.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-12",3,2.21,88.82,,0,0.001,53.129,0.059,0.011,0.0277,895.163,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-14",6,5.17,214.33,,0.001,0.001,128.155,0.0595,0.027,0.0258,2154.723,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-26",4,2.48,97.62,,0,0.001,58.814,0.0593,0.011,0.035,989.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-27",4,2.22,87.9,,0,0.001,52.683,0.0593,0.011,0.0835,887.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-28",5,3.5,143.46,,0,0.001,85.054,0.0594,0.012,0.0536,1431.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-29",4,2.22,87.3,,0,0.001,52.398,0.0593,0.011,0.0823,882.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-30",4,3.2,128.32,,0,0.001,77.651,0.0593,0.012,0.022,1305.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-07-31",7,5.19,208.69,,0.001,0.001,124.994,0.0593,0.02,0.025,2103.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-09",3,2.19,86.74,,0,0.001,51.402,0.0593,0.009,0.0377,864.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-10",4,2.21,86.6,,0,0.001,51.697,0.0593,0.009,0.0838,869.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-12",4,2.96,119.98,,0,0.001,71.154,0.0593,0.01,0.0283,1197.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-13",6,4.47,183.6,,0.001,0.001,108.451,0.0592,0.012,0.0273,1825.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-14",8,6.94,292.16,,0.001,0.001,172.958,0.0594,0.016,0.0139,2909.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-15",6,5.2,218.86,,0.001,0.001,130.192,0.0593,0.013,0.014,2189.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-16",3,2.21,86.25,,0,0.001,51.931,0.059,0.009,0.0337,873.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-17",10,8.47,359,,0.001,0.001,211.978,0.0593,0.018,0.0167,3566.707,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-18",8,7.21,301.84,,0.001,0.001,179.822,0.0593,0.015,0.015,3026.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-19",8,7.45,307.09,,0.001,0.001,182.702,0.0594,0.016,0.0121,3072.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-20",5,3.75,150.42,,0,0.001,90.07,0.0592,0.01,0.0532,1515.886,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-24",6,5.23,210.45,,0.001,0.001,125.811,0.0592,0.011,0.0135,2118.613,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-25",3,2.21,84.8,,0,0.001,51.306,0.0593,0.008,0.0317,862.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-26",5,3.95,157.64,,0,0.001,94.043,0.0592,0.01,0.016,1583.659,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-27",4,2.7,105.31,,0,0.001,63.672,0.0593,0.008,0.0238,1070.849,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-28",3,2.2,84.69,,0,0.001,50.913,0.0593,0.008,0.0217,855.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-29",3,2.2,84.92,,0,0.001,50.997,0.059,0.008,0.035,858.362,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-03",5,3.45,137.16,,0,0.001,82.157,0.0592,0.01,0.0568,1383.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-04",6,5.02,202.68,,0.001,0.001,122.46,0.0595,0.012,0.0443,2059.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-05",11,10.37,432.95,,0.001,0.001,259.018,0.0593,0.017,0.0124,4358.237,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-06",12,11.54,485.44,,0.001,0.001,290.786,0.0594,0.025,0.0108,4890.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-09",3,2.23,86.47,,0,0.001,52.313,0.0593,0.011,0.0233,879.231,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-15",4,2.95,116.84,,0,0.001,70.057,0.0595,0.01,0.0208,1177.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-16",3,2.18,84.61,,0,0.001,50.807,0.059,0.009,0.0397,855.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-17",3,2.21,85.89,,0,0.001,51.465,0.0597,0.012,0.026,865.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-18",6,4.4,168.59,,0.001,0.001,101.209,0.0592,0.02,0.0325,1702.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-19",4,2.96,117.32,,0,0.001,70.056,0.0593,0.011,0.0325,1178.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-01",5,3.95,158.27,,0,0.001,94.036,0.0594,0.011,0.0178,1580.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-04",4,2.45,93.77,,0,0.001,56.429,0.0593,0.011,0.053,949.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-05",5,4.45,180.27,,0.001,0.001,107.228,0.0594,0.013,0.0178,1804.323,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-06",1,0.03,0,,0,0.001,0.111,0.059,0,0.009,1.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-12",5,3.7,147.78,,0,0.001,88.855,0.0592,0.007,0.0138,1495.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-13",7,4.92,192.01,,0.001,0.001,115.45,0.0591,0.019,0.0523,1943.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-14",6,4.92,199.48,,0.001,0.001,119.02,0.0593,0.014,0.0178,2002.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-16",3,2.2,83.09,,0,0.001,50.694,0.0593,0.009,0.0393,852.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-19",7,5.11,199.18,,0.001,0.001,119.521,0.0591,0.023,0.039,2011.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-20",3,2.2,85.3,,0,0.001,51.405,0.0593,0.011,0.0253,864.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-21",3,2.7,107.47,,0,0.001,64.356,0.0593,0.013,0.0243,1082.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-22",11,9.97,409.77,,0.001,0.001,243.25,0.0593,0.022,0.0287,4093.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-26",6,3.97,152.17,,0,0.001,91.44,0.0595,0.021,0.0437,1537.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-01",4,2.18,83.6,,0,0.001,50.688,0.059,0.012,0.0803,853.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-02",3,2.2,85.29,,0,0.001,51.188,0.0597,0.009,0.0377,860.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-04",3,2.18,83.21,,0,0.001,50.36,0.0593,0.009,0.0427,846.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-05",4,0.62,15.42,,0,0.0008,10.279,0.059,0.011,0.1018,172.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-06",4,2.46,95.78,,0,0.001,56.949,0.0593,0.011,0.0868,957.989,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-09",2,1.13,40.3,,0,0.001,24.518,0.059,0.009,0.06,412.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-11",3,2.2,85.41,,0,0.001,50.952,0.0593,0.01,0.0463,857.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-16",3,2.18,85,,0,0.001,50.82,0.0593,0.01,0.0447,854.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-17",9,8.22,346.78,,0.001,0.001,204.818,0.0591,0.025,0.0156,3446.559,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-01",10,7.13,292.15,,0.001,0.001,172.596,0.0591,0.029,0.0252,2905.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-02",19,18.18,775.66,,0.002,0.001,457.05,0.0592,0.034,0.0108,7692.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-03",6,4.36,174.17,,0.001,0.001,103.762,0.0592,0.024,0.026,1747.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-06",7,5.53,227.52,,0.001,0.001,134.697,0.0591,0.027,0.0326,2267.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-07",11,7.67,299.13,,0.001,0.001,179.855,0.0592,0.033,0.0219,3025.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-08",14,11.27,440.47,,0.001,0.001,263.208,0.0592,0.033,0.0264,4429.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-09",15,12.81,514.54,,0.002,0.001,306.859,0.0591,0.03,0.0303,5163.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-10",6,3.45,126.81,,0,0.001,76.714,0.0593,0.012,0.0413,1290.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-12",10,7.44,298.3,,0.001,0.001,176.984,0.059,0.027,0.0328,2980.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-13",7,5.38,212.15,,0.001,0.001,126.556,0.0593,0.021,0.0247,2128.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-14",6,4.38,172.84,,0.001,0.001,103.27,0.0593,0.021,0.0333,1737.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-15",13,11.38,474.84,,0.001,0.001,280.256,0.0592,0.037,0.0175,4716.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-16",16,13.03,535.91,,0.002,0.001,317.391,0.0594,0.045,0.0253,5340.043,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-17",9,7.34,302.88,,0.001,0.001,179.154,0.0593,0.02,0.015,3013.194,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-18",5,3.41,140.01,,0,0.001,83.012,0.0592,0.012,0.0454,1396.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-19",10,8.06,324.72,,0.001,0.001,194.028,0.0593,0.033,0.0199,3264.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-20",10,7.58,304.91,,0.001,0.001,182.423,0.0594,0.031,0.03,3068.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-21",18,16.68,706.69,,0.002,0.001,416.758,0.0592,0.036,0.0131,7012.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-22",20,18.68,796.94,,0.002,0.001,469.515,0.0592,0.033,0.0145,7902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-23",4,2.61,101.38,,0,0.001,60.573,0.0593,0.012,0.0233,1019.109,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-24",17,14.86,621.27,,0.002,0.001,367.082,0.0593,0.042,0.0199,6175.387,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-25",9,6.29,251.6,,0.001,0.001,150.673,0.0593,0.026,0.0243,2536.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-26",5,4.18,172.42,,0.001,0.001,102.474,0.059,0.017,0.02,1725.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-27",8,5.9,243.26,,0.001,0.001,144.156,0.0594,0.024,0.0244,2424.598,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-28",10,8.09,349.58,,0.001,0.001,206.263,0.0595,0.031,0.0298,3470.271,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-29",16,14.7,639.18,,0.002,0.001,376.652,0.0591,0.03,0.0121,6337.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-30",14,11.93,501.85,,0.001,0.001,296.997,0.0592,0.033,0.0164,4996.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-01-31",18,16.22,690.2,,0.002,0.001,407.79,0.0595,0.036,0.0127,6858.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-01",4,2.36,89.66,,0,0.001,54.058,0.059,0.015,0.0288,910.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-03",12,10.87,453.58,,0.001,0.001,266.878,0.0591,0.032,0.0154,4491.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-04",13,9.8,399.44,,0.001,0.001,237.8,0.0591,0.035,0.0207,4000.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-05",19,18.23,777.04,,0.002,0.001,459.74,0.0591,0.034,0.0109,7737.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-06",4,3.18,127.23,,0,0.001,76.107,0.059,0.013,0.0565,1281.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-07",13,10.39,431.25,,0.001,0.001,256.407,0.0592,0.033,0.0182,4313.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-08",3,2.23,89.06,,0,0.001,53.072,0.059,0.01,0.0303,894.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-09",5,4.47,183.51,,0.001,0.001,108.588,0.0592,0.017,0.0186,1825.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-10",18,17.16,728.34,,0.002,0.001,429.414,0.0593,0.04,0.0127,7223.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-11",19,18.16,775.78,,0.002,0.001,458.044,0.0592,0.036,0.0104,7707.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-12",13,11.86,497.06,,0.001,0.001,293.764,0.0592,0.034,0.0147,4945.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-13",17,12.52,507.89,,0.002,0.001,302.315,0.0594,0.041,0.0258,5087.189,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-14",8,5.82,231.03,,0.001,0.001,138.42,0.0591,0.025,0.0334,2328.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-15",2,1.2,47,,0,0.001,28.08,0.059,0.002,0.0105,473.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-16",3,2.25,88.55,,0,0.001,53.3,0.0593,0.01,0.0297,896.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-17",8,4.92,196.54,,0.001,0.001,117.112,0.0593,0.024,0.0275,1970.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-18",14,11.55,474.42,,0.001,0.001,280.479,0.0593,0.037,0.0171,4718.678,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-19",15,12.82,534.64,,0.002,0.001,314.116,0.0593,0.039,0.0179,5285.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-20",23,19.5,810.88,,0.002,0.001,479.458,0.0591,0.046,0.0134,8070.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-21",6,4.43,183.76,,0.001,0.001,108.631,0.0592,0.013,0.0375,1827.933,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-22",1,0.12,0,,0,0.001,0.648,0.06,0.001,0.126,10.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-28",2,0.4,9.9,,0,0.001,6.76,0.0595,0.008,0.1605,113.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-02-29",3,2.68,105.09,,0,0.001,63.994,0.059,0.008,0.0173,1077.431,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-01",12,8.83,364.43,,0.001,0.001,217.419,0.0591,0.035,0.0269,3660.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-02",11,10.61,444.43,,0.001,0.001,263.105,0.0593,0.034,0.0152,4427.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-03",14,11.33,458.53,,0.001,0.001,274.211,0.0594,0.027,0.0146,4613.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-04",10,7.38,292.62,,0.001,0.001,175.623,0.0593,0.032,0.0329,2955.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-05",14,9.34,373.17,,0.001,0.001,223.712,0.0592,0.031,0.0237,3763.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-06",4,3.16,128.8,,0,0.001,77.266,0.0595,0.015,0.0228,1299.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-07",7,5.61,225.08,,0.001,0.001,136.383,0.0591,0.023,0.0224,2296.191,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-08",6,5.4,225.26,,0.001,0.001,135.317,0.059,0.017,0.0173,2278.183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-09",9,5.91,231.21,,0.001,0.001,140.437,0.0594,0.024,0.0308,2362.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-10",14,10.62,420.08,,0.001,0.001,256.16,0.0591,0.036,0.0189,4312.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-11",20,16.58,702.22,,0.002,0.001,419.948,0.0593,0.03,0.0103,7066.446,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-12",21,18.93,814.27,,0.002,0.001,486.704,0.0591,0.038,0.0123,8190.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-13",14,13.3,577.4,,0.002,0.001,344.822,0.0592,0.027,0.0111,5803.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-14",23,19.81,851.08,,0.003,0.001,507.711,0.0592,0.042,0.0151,8543.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-15",6,5.18,220.6,,0.001,0.001,131.446,0.0592,0.018,0.0177,2212.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-16",18,16.75,712.9,,0.002,0.001,424.255,0.0591,0.032,0.0112,7141.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-17",4,2.23,89.2,,0,0.001,53.433,0.0593,0.014,0.037,898.103,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-18",19,18.98,813.2,,0.002,0.001,481.92,0.0591,0.041,0.0104,8112.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-19",23,21.65,919.11,,0.003,0.001,546.434,0.0591,0.035,0.0082,9195.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-20",3,1.77,61.42,,0,0.001,37.963,0.0597,0.022,0.079,638.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-21",5,3.42,138.94,,0,0.001,83.356,0.059,0.012,0.053,1403.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-23",18,17.45,742.1,,0.002,0.001,441.33,0.0591,0.034,0.0115,7426.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-24",19,17.7,753.38,,0.002,0.001,449.444,0.0593,0.034,0.0118,7562.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-25",15,13.38,560.54,,0.002,0.001,337.522,0.0593,0.037,0.0161,5677.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-26",14,13.12,549.19,,0.002,0.001,327.611,0.059,0.029,0.0217,5516.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-27",4,3.7,149.6,,0,0.001,90.17,0.0598,0.017,0.0218,1515.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-28",4,3.68,151.1,,0,0.001,90.704,0.0593,0.017,0.0218,1526.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-29",4,2.93,119.03,,0,0.001,71.181,0.0593,0.012,0.0545,1198.107,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-30",7,5.7,237.7,,0.001,0.001,140.91,0.059,0.016,0.0203,2372.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-03-31",18,17.95,765.05,,0.002,0.001,450.13,0.0593,0.036,0.0097,7573.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-01",18,16.68,709.92,,0.002,0.001,420.428,0.0593,0.032,0.0119,7074.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-02",9,6.73,274.24,,0.001,0.001,163.537,0.0593,0.028,0.0308,2751.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-03",6,4.47,181.65,,0.001,0.001,108.543,0.0592,0.024,0.0358,1825.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-04",1,0.2,4.2,,0,0.001,3.08,0.06,0.001,0.03,51.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-05",7,5.46,227.28,,0.001,0.001,134.686,0.0593,0.015,0.0314,2265.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-06",17,14.9,625.2,,0.002,0.001,369.844,0.0592,0.034,0.0143,6221.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-10",7,5.68,236.53,,0.001,0.001,141.032,0.0591,0.016,0.0354,2372.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-13",7,6.2,258.82,,0.001,0.001,154.222,0.0593,0.02,0.0167,2594.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-14",4,3.17,124.9,,0,0.001,74.756,0.059,0.019,0.0628,1258.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-15",9,6.85,271.45,,0.001,0.001,162.83,0.0592,0.034,0.0237,2740.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-16",13,11.36,473.8,,0.001,0.001,281.44,0.0592,0.035,0.0157,4737.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-17",24,21.32,888.68,,0.003,0.001,528.871,0.0593,0.048,0.0124,8895.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-18",5,4.43,182.86,,0.001,0.001,109.135,0.059,0.014,0.0234,1836.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-19",6,4.68,193.28,,0.001,0.001,115.452,0.0592,0.014,0.0225,1942.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-20",18,17.23,737.9,,0.002,0.001,437.839,0.0593,0.033,0.0171,7364.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-21",23,19.28,799.16,,0.002,0.001,476.959,0.059,0.045,0.0147,8028.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-22",13,11.26,473.01,,0.001,0.0009,281.817,0.0592,0.03,0.0162,4744.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-23",20,18.43,779.91,,0.002,0.001,465.939,0.0593,0.035,0.0097,7838.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-24",19,16.97,716.25,,0.002,0.001,426.278,0.0592,0.041,0.0138,7172.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-25",12,11.65,493.2,,0.001,0.001,294.065,0.0591,0.027,0.0113,4949.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-26",11,10.07,424.95,,0.001,0.001,253.847,0.0592,0.021,0.0131,4271.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-27",2,1.97,79.86,,0,0.001,48.295,0.059,0.003,0.008,812.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-29",6,5.18,216.8,,0.001,0.001,129.46,0.0593,0.04,0.0347,2178.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-01",8,5.63,227.93,,0.001,0.001,137.305,0.059,0.02,0.034,2311.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-04",3,2.22,88.14,,0,0.001,53.166,0.0593,0.01,0.0313,894.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-05",7,6.68,280.1,,0.001,0.001,167.136,0.0591,0.019,0.0137,2813.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-08",3,2.18,86,,0,0.001,51.882,0.059,0.01,0.0653,873.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-09",3,2.22,88.42,,0,0.001,52.478,0.0593,0.01,0.0563,882.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-26",3,1.75,71.24,,0,0.0007,43.035,0.059,0.012,0.049,724.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-27",4,2.27,84.3,,0,0.001,52.183,0.0593,0.01,0.0993,877.519,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-28",2,0.38,0,,0,0.001,1.946,0.06,0.003,0.146,32.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-30",6,4.67,186.39,,0.001,0.001,112.59,0.0595,0.02,0.0268,1893.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-01",3,2.2,86.98,,0,0.001,53.019,0.059,0.012,0.028,893.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-08",3,2.15,83.89,,0,0.001,51.674,0.059,0.015,0.031,869.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-09",7,4.66,188.98,,0.001,0.001,114.161,0.0591,0.019,0.0404,1921.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-10",4,2.57,93.38,,0,0.001,58.485,0.059,0.016,0.0788,983.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-11",3,2.18,86.6,,0,0.001,53.328,0.0593,0.013,0.0247,896.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-26",3,2.24,88.23,,0,0.001,54.238,0.059,0.01,0.0587,913.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-27",4,2.45,96.29,,0,0.001,59.225,0.0593,0.01,0.054,997.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-03",3,2.19,86.34,,0,0.001,52.362,0.059,0.012,0.0277,881.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-04",3,2.2,86.25,,0,0.001,52.746,0.059,0.011,0.026,887.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-05",4,2.68,107.74,,0,0.001,65.184,0.0598,0.01,0.0503,1096.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-06",3,2.2,85.28,,0,0.001,52.07,0.059,0.012,0.0257,876.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-07",3,2.2,86.3,,0,0.001,52.535,0.059,0.009,0.065,883.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-09",5,3.5,142.7,,0,0.001,86.326,0.0596,0.012,0.036,1451.634,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-10",3,2.54,101.62,,0,0.001,62.068,0.0597,0.012,0.0233,1043.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-11",8,6.7,280.55,,0.001,0.001,168.92,0.059,0.016,0.0249,2844.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-12",3,2.2,85.96,,0,0.001,52.432,0.0593,0.01,0.025,882.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-15",8,6.95,291.85,,0.001,0.001,175.555,0.0593,0.026,0.0198,2955.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-25",3,2.2,86.76,,0,0.001,52.688,0.0593,0.01,0.0643,886.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-26",3,2.47,98.86,,0,0.001,59.98,0.0593,0.01,0.0287,1009.162,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-27",3,2.22,87.86,,0,0.001,53.592,0.059,0.01,0.056,901.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-28",5,3.49,142.7,,0,0.001,85.979,0.0594,0.012,0.0374,1445.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-29",3,2.18,86.46,,0,0.001,52.692,0.0593,0.01,0.0603,886.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-30",4,3.43,139.37,,0,0.001,84.907,0.0593,0.013,0.0205,1428.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-07-31",7,5.17,205.9,,0.001,0.0009,125.699,0.0591,0.019,0.0167,2115.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-09",3,2.19,87.03,,0,0.001,52.904,0.0593,0.01,0.033,890.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-10",3,2.2,85.44,,0,0.001,52.624,0.059,0.01,0.032,886.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-12",4,2.69,108.14,,0,0.001,66.147,0.059,0.01,0.0538,1113.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-13",5,4.44,182.31,,0.001,0.001,110.982,0.0594,0.013,0.0214,1868.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-14",8,6.92,289.66,,0.001,0.001,176.984,0.0594,0.018,0.0144,2976.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-15",6,4.94,204.42,,0.001,0.001,125.244,0.0592,0.014,0.0157,2106.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-16",3,2.19,87.03,,0,0.001,53.705,0.0593,0.009,0.029,903.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-17",9,7.95,333.26,,0.001,0.001,202.056,0.0591,0.018,0.0141,3402.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-18",8,7.21,299.29,,0.001,0.001,182.84,0.0591,0.016,0.0144,3077.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-19",7,6.45,263.66,,0.001,0.001,161.599,0.0591,0.016,0.0139,2718.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-20",5,4.25,171.5,,0.001,0.001,105.35,0.059,0.013,0.0164,1773.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-23",2,1.35,49.83,,0,0.001,31.307,0.059,0.011,0.032,526.661,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-24",3,2.43,94.42,,0,0.001,58.531,0.0593,0.013,0.024,984.481,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-25",3,2.19,84.84,,0,0.001,52.732,0.0593,0.009,0.0287,886.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-26",4,2.94,115.26,,0,0.001,71.014,0.0593,0.012,0.0218,1196.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-27",7,5.14,200.85,,0.001,0.001,124.561,0.0591,0.018,0.0349,2097.007,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-28",3,2.17,84.21,,0,0.001,52.167,0.0593,0.01,0.0247,877.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-29",3,2.2,84.72,,0,0.001,52.6,0.0597,0.009,0.0303,884.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-03",5,3.45,137.28,,0,0.001,84.098,0.0592,0.011,0.0416,1415.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-04",6,4.4,168.25,,0.001,0.001,104.052,0.0592,0.016,0.0493,1750.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-05",11,9.95,409.76,,0.001,0.001,249.604,0.0592,0.021,0.0129,4198.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-06",11,10.18,429.24,,0.001,0.001,258.526,0.0591,0.022,0.0233,4351.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-09",3,2.21,87.95,,0,0.001,53.243,0.0593,0.012,0.0237,895.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-10",6,4.45,176.2,,0.001,0.001,106.455,0.0592,0.022,0.0248,1792.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-14",6,4.38,173.84,,0.001,0.001,105.998,0.0592,0.019,0.0263,1784.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-15",3,2.42,97.66,,0,0.001,59.334,0.0593,0.011,0.0257,998.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-16",3,2.18,85.65,,0,0.001,52.283,0.059,0.01,0.0333,880.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-17",3,2.3,89.11,,0,0.001,54.603,0.0593,0.01,0.0463,918.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-18",10,8.39,337.24,,0.001,0.001,203.905,0.0595,0.024,0.0183,3429.727,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-19",3,2.98,117.24,,0,0.001,70.938,0.059,0.014,0.023,1195.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-20",3,2.18,83.66,,0,0.001,50.764,0.0597,0.009,0.0737,853.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-21",3,2.17,84.03,,0,0.001,50.858,0.0593,0.013,0.026,854.927,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-29",1,0.97,38.8,,0,0.001,23.183,0.059,0.012,0.06,390.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-09-30",2,1.47,57.04,,0,0.001,34.882,0.059,0.002,0.0085,587.637,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-01",5,3.93,158.14,,0,0.001,94.95,0.059,0.014,0.0204,1598.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-02",3,2.2,82.98,,0,0.001,51.102,0.0593,0.009,0.0697,859.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-04",4,2.95,117.02,,0,0.001,70.647,0.059,0.013,0.0248,1188.751,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-05",7,5.14,201.47,,0.001,0.001,122.535,0.059,0.022,0.0209,2063.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-06",6,4.63,179.98,,0.001,0.001,109.527,0.0592,0.021,0.026,1843.575,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-07",1,0.18,1.08,,0,0.001,1.422,0.06,0.003,0.245,23.886,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-23",2,1.37,50.93,,0,0.001,31.232,0.059,0.008,0.0245,525.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-26",11,9.4,378.09,,0.001,0.001,228.132,0.059,0.042,0.0255,3839.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-27",3,2.23,86.28,,0,0.001,52.062,0.0593,0.013,0.043,876.501,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-01",2,0.42,10.28,,0,0.001,7.058,0.06,0.002,0.032,118.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-02",3,2.19,83.43,,0,0.001,51.323,0.0597,0.009,0.029,862.293,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-04",3,2.16,83.33,,0,0.001,50.88,0.06,0.011,0.0397,854.886,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-05",6,4.47,180.78,,0.001,0.001,108.696,0.059,0.014,0.036,1829.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-06",4,2.48,97.29,,0,0.001,58.378,0.0593,0.013,0.0555,981.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-13",2,1,34.92,,0,0.001,21.784,0.059,0.014,0.092,366.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-14",3,2.19,84.8,,0,0.001,51.595,0.0597,0.013,0.0827,866.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-16",5,4.45,179.65,,0.001,0.001,107.745,0.0592,0.016,0.0222,1813.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-19",9,8.19,336.14,,0.001,0.001,202.394,0.059,0.027,0.0167,3407.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-11",3,2.2,83.85,,0,0.001,51.015,0.059,0.009,0.0297,859.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Miramar Energy Facility",56232,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-26",4,2.29,85.47,,0,0.001,53.974,0.0593,0.009,0.0435,908.912,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-12",3,2.3,86,,0,0.001,53.898,0.059,0.01,0.0197,907.488,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-13",7,4.66,174.81,,0.001,0.001,108.748,0.0591,0.018,0.0383,1830.317,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-14",5,3.97,80.52,,0,0.001,61.419,0.0594,0.035,0.0894,1032.48,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-11",5,2.76,93.04,,0,0.001,54.451,0.0596,0.016,0.0634,915.33,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-16",2,0.98,35.36,,0,0.001,20.228,0.0595,0.008,0.067,340.104,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-22",2,1,36,,0,0.001,20.72,0.059,0.007,0.0675,349.13,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-23",2,0.95,17.48,,0,0.001,12.585,0.059,0.005,0.075,212.185,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-26",3,2.22,76.94,,0,0.001,44.94,0.059,0.008,0.046,756.022,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-27",4,0.97,0.25,,0,0.001,5.653,0.059,0.013,0.278,95.544,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-02",2,0.91,17.51,,0,0.001,12.305,0.06,0.005,0.076,206.524,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-03",4,2.45,73.84,,0,0.001,44.447,0.0593,0.006,0.037,747.434,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-04",2,1.21,23.64,,0,0.001,16.539,0.0595,0.004,0.063,277.72,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-08",2,1.32,40.25,,0,0.001,24.284,0.0595,0.01,0.0425,408.443,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-09",3,1.98,65.76,,0,0.001,38.99,0.0597,0.008,0.0523,655.698,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-10",3,2.73,79.62,,0,0.001,48.962,0.0597,0.008,0.0213,823.336,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-16",10,9.24,381.87,,0.001,0.001,214.31,0.0591,0.019,0.0119,3605.354,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-25",2,0.97,23,,0,0.001,14.806,0.059,0.005,0.074,249.367,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-06-30",2,1.2,38.04,,0,0.001,22.644,0.06,0.007,0.026,380.334,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-09",2,1.23,25.23,,0,0.001,17.196,0.0595,0.004,0.051,289.26,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-11",3,2.77,102.56,,0,0.001,58.857,0.059,0.009,0.02,990.969,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-12",3,1.91,59.24,,0,0.001,35.356,0.0593,0.007,0.0227,594.91,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-24",3,2.02,53.17,,0,0.001,33.558,0.059,0.004,0.0117,564.767,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-26",2,1.02,18.74,,0,0.001,13.482,0.0595,0.005,0.065,226.854,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-29",3,1.77,54.06,,0,0.001,32.554,0.0593,0.007,0.042,547.394,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-30",5,2.4,70.14,,0,0.001,43.065,0.0596,0.01,0.0136,723.039,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-07-31",2,0.93,24.48,,0,0.001,15.336,0.06,0.004,0.022,257.502,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-06",3,2.22,45.05,,0,0.001,31.385,0.0593,0.004,0.0153,527.935,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-10",2,0.98,18.05,,0,0.001,12.975,0.0595,0.005,0.045,218.823,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-12",2,1,18.05,,0,0.001,13.155,0.0595,0.005,0.0605,222.045,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-13",6,5.55,202.74,,0.001,0.001,116.39,0.0592,0.01,0.0127,1958.725,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-14",8,6.95,221,,0.001,0.001,132.749,0.0594,0.012,0.0138,2232.729,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-15",9,8.01,277.65,,0.001,0.001,162.869,0.0594,0.014,0.0171,2740.438,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-16",7,5.75,210.8,,0.001,0.001,121.125,0.0591,0.017,0.0207,2037.836,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-17",11,9.52,383.28,,0.001,0.001,216.96,0.0594,0.016,0.0114,3649.962,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-18",13,11.7,445.27,,0.001,0.001,254.583,0.0591,0.02,0.0145,4285.388,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-19",9,8.01,318.35,,0.001,0.001,179.715,0.0592,0.015,0.0122,3023.996,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-22",2,1.07,21.47,,0,0.001,14.908,0.059,0.009,0.067,251.217,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-24",2,0.98,18.78,,0,0.001,13.372,0.059,0.004,0.0265,225.036,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-27",3,1.87,67.23,,0,0.001,38.626,0.059,0.007,0.0193,650.17,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-04",2,0.97,18.77,,0,0.001,13.057,0.059,0.005,0.027,219.918,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-05",4,3,89.43,,0,0.001,54.991,0.0593,0.009,0.0338,924.893,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-06",5,4.23,163.78,,0,0.001,92.584,0.0594,0.012,0.0232,1557.631,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-09",2,0.95,19.45,,0,0.001,13.405,0.059,0.005,0.0635,225.69,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-11",1,0.95,23.75,,0,0.001,15.2,0.059,0.007,0.051,256.025,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-15",2,0.97,23.75,,0,0.001,15.411,0.059,0.005,0.0245,259.21,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-16",2,0.93,17.73,,0,0.001,12.692,0.0595,0.003,0.019,213.314,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-19",3,2.25,45.76,,0,0.001,31.425,0.0593,0.005,0.0523,529.081,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-24",4,2.69,85.74,,0,0.001,50.27,0.059,0.011,0.0278,847.226,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-28",2,1.23,42.04,,0,0.001,24.632,0.059,0.005,0.052,414.484,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-29",4,3.03,101.39,,0,0.001,58.49,0.0593,0.011,0.0235,984.863,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-09-30",4,2.7,68.82,,0,0.001,43.055,0.0593,0.004,0.014,725.046,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-01",2,1.2,23.3,,0,0.001,16.11,0.0595,0.004,0.0325,270.74,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-02",2,0.95,18.1,,0,0.001,12.465,0.0595,0.005,0.0405,209.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-03",2,1.02,37.82,,0,0.001,21.094,0.06,0.007,0.026,354.387,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-04",2,1.49,48.8,,0,0.001,28.095,0.0595,0.007,0.024,472.539,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-05",4,3.2,106.6,,0,0.001,62.608,0.0595,0.008,0.0145,1052.632,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-14",4,2.99,108.05,,0,0.001,61.887,0.059,0.007,0.027,1041.075,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-15",4,3.12,75.04,,0,0.001,48.774,0.0593,0.005,0.0123,821.815,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-16",2,0.99,18.87,,0,0.001,13.452,0.059,0.003,0.0155,226.464,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-17",2,0.99,18.63,,0,0.001,13.218,0.059,0.003,0.0215,222.684,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-19",2,1.02,25.59,,0,0.001,16.167,0.0595,0.005,0.024,271.797,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-21",2,0.99,18.32,,0,0.001,13.231,0.0595,0.004,0.0285,222.648,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-23",2,0.99,19.47,,0,0.001,13.395,0.06,0.006,0.101,224.94,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-27",2,1.03,41.03,,0,0.001,22.965,0.059,0.009,0.0265,386.456,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-01",2,1.01,19.39,,0,0.001,13.614,0.059,0.004,0.021,229.121,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-02",2,1.25,23.75,,0,0.001,16.973,0.0595,0.004,0.0425,285.601,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-03",2,0.97,18.57,,0,0.001,13.074,0.0595,0.004,0.024,219.722,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-04",3,2.23,46.43,,0,0.001,31.706,0.0593,0.005,0.0183,533.421,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-05",5,3.77,79.36,,0,0.001,53.869,0.0596,0.005,0.014,906.478,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-06",2,1.19,23.51,,0,0.001,15.83,0.0595,0.005,0.027,265.857,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-08",2,1,18.08,,0,0.001,12.644,0.06,0.004,0.027,212.216,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-09",3,1.27,24.4,,0,0.001,16.639,0.0597,0.006,0.0817,279.566,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-10",2,0.99,17.88,,0,0.001,12.621,0.06,0.006,0.035,212.028,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-11",4,1.99,36.1,,0,0.001,25.435,0.0595,0.008,0.0475,428.61,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-13",2,0.99,18.12,,0,0.001,12.804,0.06,0.005,0.0255,214.968,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-15",4,2.5,110.4,,0,0.001,58.49,0.0595,0.009,0.0338,983.73,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-16",3,1.24,23.68,,0,0.001,16.368,0.059,0.005,0.0867,275.94,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-20",2,1,18.2,,0,0.001,12.816,0.0595,0.004,0.0265,215.188,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-21",2,0.99,18,,0,0.001,12.582,0.0595,0.004,0.027,211.989,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-22",2,1.08,19.78,,0,0.001,13.865,0.059,0.004,0.022,233.092,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-29",2,0.99,18,,0,0.001,12.693,0.0595,0.003,0.0235,214.137,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-01",4,1.98,39.33,,0,0.001,27.042,0.0598,0.007,0.0513,454.884,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-02",2,0.99,18,,0,0.001,12.768,0.0595,0.004,0.024,214.851,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-03",3,1.99,40.81,,0,0.001,27.468,0.0593,0.005,0.0343,462.542,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-04",4,2.26,68.7,,0,0.001,40.658,0.0593,0.01,0.0273,684.002,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-05",2,0.99,18,,0,0.001,12.831,0.0595,0.006,0.033,215.211,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-06",2,0.99,18.32,,0,0.001,12.785,0.059,0.004,0.027,215.278,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-08",2,0.99,17.82,,0,0.001,12.759,0.059,0.003,0.039,214.873,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-11",3,1.74,34.95,,0,0.001,23.624,0.0593,0.003,0.025,397.454,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-12",3,2.25,91.52,,0,0.001,50.297,0.0597,0.008,0.0343,845.996,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-13",2,0.94,35.66,,0,0.001,19.84,0.059,0.005,0.043,334.31,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-14",5,2.98,68.67,,0,0.001,44.583,0.0592,0.011,0.0634,750.443,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-15",4,1.98,47.45,,0,0.001,30.668,0.0595,0.007,0.0538,516.584,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-16",6,4.02,152.27,,0,0.001,85.174,0.0595,0.011,0.024,1432.073,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-20",2,0.98,18.6,,0,0.001,12.986,0.0595,0.004,0.0775,218.41,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-26",4,2.29,86.3,,0,0.001,50.255,0.059,0.008,0.0575,845.51,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-12",3,2.3,86.42,,0,0.001,50.78,0.0597,0.007,0.0147,853.13,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-13",7,4.64,174.68,,0.001,0.001,101.684,0.0591,0.014,0.034,1710.882,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-14",3,2.5,95,,0,0.001,55.492,0.0593,0.006,0.0157,932.904,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-14",5,3.79,76.43,,0,0.001,53.691,0.0594,0.024,0.07,904.156,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-10",2,1.88,68.4,,0,0.001,38.576,0.059,0.011,0.0405,649.816,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-16",1,0.13,0,,0,0.001,0.689,0.059,0.001,0.245,11.648,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-22",2,1,37,,0,0.001,20.79,0.059,0.007,0.0655,350.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-23",2,0.95,17.48,,0,0.001,12.303,0.0595,0.004,0.041,207.088,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-25",2,0.92,25.18,,0,0.001,15.584,0.059,0.005,0.06,262.712,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-26",3,2.22,78.24,,0,0.001,44.878,0.0593,0.006,0.0347,754.334,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-27",3,1.5,54.6,,0,0.001,30.96,0.0593,0.005,0.032,521.27,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-01",2,1.07,22.47,,0,0.001,14.873,0.06,0.005,0.083,249.584,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-02",2,0.91,17.51,,0,0.001,11.918,0.0595,0.003,0.061,200.897,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-03",4,2.45,73.84,,0,0.001,43.757,0.0595,0.004,0.0285,735.67,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-04",2,1.21,23.64,,0,0.001,16.083,0.059,0.003,0.05,270.991,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-08",2,1.32,41.57,,0,0.001,24.114,0.0595,0.008,0.035,405.356,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-09",3,1.98,66.76,,0,0.001,38.466,0.0593,0.005,0.0393,647.39,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-10",3,2.73,81.4,,0,0.001,48.516,0.0593,0.005,0.0147,816.562,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-16",2,0.91,16.6,,0,0.001,11.736,0.0595,0.003,0.0495,196.989,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-17",9,8.77,386.31,,0.001,0.001,211.452,0.0592,0.018,0.0114,3557.755,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-25",2,0.97,23.05,,0,0.001,14.622,0.0595,0.004,0.0745,245.324,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-06-30",2,1.2,39.6,,0,0.001,22.674,0.06,0.005,0.019,380.652,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-09",2,1.23,25.23,,0,0.001,16.983,0.0595,0.003,0.0385,285.351,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-11",3,2.77,104.38,,0,0.001,58.39,0.059,0.007,0.0153,984.428,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-12",3,2.76,81.63,,0,0.001,48.677,0.059,0.006,0.0163,819.94,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-16",2,0.95,25.85,,0,0.001,15.868,0.0595,0.005,0.0325,266.678,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-24",2,0.98,19,,0,0.001,13.036,0.0595,0.004,0.06,218.942,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-25",2,1,19.7,,0,0.001,13.26,0.059,0.004,0.051,223.81,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-26",2,1.02,19.06,,0,0.001,13.31,0.059,0.004,0.05,224.51,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-27",2,0.98,18.6,,0,0.001,12.966,0.06,0.004,0.0445,217.582,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-29",3,1.77,54.38,,0,0.001,32.064,0.0593,0.007,0.0383,539.742,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-30",5,2.4,72.14,,0,0.001,42.668,0.0594,0.007,0.0108,718.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-07-31",2,0.93,24.48,,0,0.001,14.925,0.059,0.004,0.0185,251.676,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-06",3,2.22,45.05,,0,0.001,30.642,0.0593,0.003,0.014,515.638,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-10",2,0.98,18.05,,0,0.0005,12.782,0.06,0.004,0.0285,214.791,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-12",2,1,18.05,,0,0.001,12.87,0.059,0.004,0.05,216.955,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-13",6,5.55,206.46,,0.001,0.001,116.186,0.0595,0.01,0.012,1954.144,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-14",8,6.95,223.97,,0.001,0.001,130.903,0.0594,0.011,0.0114,2203.671,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-15",9,8.01,284.66,,0.001,0.001,162.324,0.0591,0.012,0.015,2733.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-16",7,5.75,215.63,,0.001,0.001,121.844,0.0594,0.017,0.021,2048.052,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-17",11,9.54,394.92,,0.001,0.001,218.716,0.0592,0.014,0.0097,3680.756,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-18",14,12.62,480.89,,0.001,0.001,271.369,0.0594,0.021,0.0141,4564.36,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-19",9,8.01,325.58,,0.001,0.001,181.204,0.0591,0.014,0.0113,3051.161,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-22",4,1.93,34.4,,0,0.001,24.464,0.0593,0.006,0.0305,412.039,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-23",1,0.27,2.7,,0,0.001,2.484,0.059,0.002,0.116,41.823,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-24",2,0.98,18.78,,0,0.001,13.098,0.0595,0.003,0.0265,220.126,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-27",2,1.02,34.68,,0,0.001,19.854,0.0595,0.006,0.0215,334.02,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-04",2,0.97,18.77,,0,0.001,12.786,0.0595,0.003,0.02,214.615,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-05",2,0.4,0,,0,0.001,2.2,0.0595,0.005,0.252,37.002,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-06",5,4.23,165.78,,0,0.001,92.042,0.0592,0.01,0.0188,1549.563,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-09",2,0.95,19.7,,0,0.001,13.215,0.0595,0.004,0.0505,222.12,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-11",1,0.95,23.75,,0,0.001,14.915,0.059,0.005,0.038,251.37,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-16",2,0.93,17.73,,0,0.001,12.36,0.059,0.003,0.02,208.081,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-19",3,2.25,45.76,,0,0.001,30.65,0.059,0.004,0.0503,516.904,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-21",2,0.97,18.57,,0,0.001,13.074,0.0595,0.003,0.026,220.278,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-28",3,0.43,9.28,,0,0.001,6.299,0.0593,0.003,0.0323,105.936,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-29",1,0.65,15.6,,0,0.001,10.01,0.06,0.005,0.055,168.155,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-09-30",4,3.02,78.15,,0,0.001,48.403,0.0595,0.027,0.0925,814.085,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-01",2,1.2,23.3,,0,0.001,15.94,0.059,0.003,0.0225,268.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-02",2,0.95,18.1,,0,0.001,12.325,0.059,0.003,0.0305,207.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-03",2,1.02,37.82,,0,0.001,21.146,0.059,0.005,0.02,356.033,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-04",2,1.49,48.03,,0,0.001,27.715,0.059,0.006,0.023,466.938,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-05",4,3.2,75.36,,0,0.001,49.46,0.059,0.007,0.0383,833.66,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-14",4,2.99,109.05,,0,0.001,62.051,0.059,0.006,0.022,1044.923,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-15",4,3.1,74.16,,0,0.001,47.881,0.0593,0.005,0.0128,805.373,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-16",2,0.99,18.87,,0,0.001,13.278,0.0595,0.002,0.014,223.92,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-17",2,0.99,17.88,,0,0.001,12.783,0.059,0.003,0.032,215.202,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-19",2,1.02,23.85,,0,0.001,15.645,0.0595,0.005,0.023,263.472,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-20",2,1.04,21.01,,0,0.001,14.349,0.059,0.003,0.017,241.957,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-21",2,0.99,18.32,,0,0.001,13.107,0.059,0.004,0.0305,221.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-23",2,0.99,18.51,,0,0.001,12.9,0.06,0.005,0.1435,216.522,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-27",3,1.88,78.81,,0,0.001,43.353,0.0593,0.007,0.0173,729.063,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-28",2,0.99,18.75,,0,0.001,12.969,0.059,0.003,0.0305,218.601,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-01",2,1,18.31,,0,0.001,13.298,0.0595,0.004,0.0345,223.239,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-02",2,1.25,24.62,,0,0.001,16.973,0.0595,0.004,0.038,285.323,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-03",2,0.97,18.57,,0,0.001,12.9,0.0595,0.003,0.027,216.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-04",3,2.23,46.43,,0,0.001,31.395,0.0593,0.004,0.015,528.22,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-05",5,3.75,79.08,,0,0.001,53.158,0.0592,0.005,0.0156,895.772,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-06",2,1.19,22.69,,0,0.001,15.301,0.0595,0.004,0.025,257.208,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-08",2,1,18.08,,0,0.001,12.468,0.0595,0.004,0.0385,210.016,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-09",3,1.27,24.55,,0,0.001,16.357,0.0597,0.005,0.0807,275.596,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-10",2,0.99,17.88,,0,0.001,12.435,0.0595,0.004,0.035,208.689,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-11",4,1.99,35.23,,0,0.001,24.749,0.059,0.007,0.0538,416.751,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-12",2,1,18.96,,0,0.001,12.656,0.0595,0.004,0.035,213.164,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-13",2,0.99,18.12,,0,0.001,12.618,0.059,0.003,0.03,212.412,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-15",4,2.5,111.4,,0,0.001,59.24,0.0593,0.008,0.0455,995.62,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-16",3,1.24,24.68,,0,0.001,16.244,0.0593,0.004,0.092,273.072,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-20",2,1,18.2,,0,0.001,12.64,0.0595,0.003,0.0325,212.54,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-21",2,0.99,18,,0,0.001,12.396,0.0595,0.004,0.0335,208.887,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-22",2,1.08,19.78,,0,0.001,13.662,0.0595,0.003,0.0245,229.408,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-29",2,0.99,18,,0,0.001,12.594,0.059,0.003,0.0295,211.767,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-01",4,1.98,39.45,,0,0.001,26.67,0.0595,0.006,0.051,449.889,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-02",2,0.99,18,,0,0.001,12.669,0.0595,0.003,0.024,212.778,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-03",3,1.99,40.19,,0,0.001,27.07,0.059,0.004,0.03,455.426,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-04",4,2.27,68.6,,0,0.001,40.442,0.0595,0.009,0.0255,680.689,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-05",2,0.99,18,,0,0.001,12.657,0.059,0.004,0.0265,212.799,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-06",2,0.99,17.7,,0,0.001,12.624,0.0595,0.003,0.0235,212.33,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-08",2,0.99,17.82,,0,0.001,12.66,0.0595,0.003,0.039,212.795,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-11",3,1.75,34.74,,0,0.001,23.422,0.0597,0.003,0.025,393.503,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-12",3,2.25,92.52,,0,0.001,50.685,0.059,0.008,0.0307,853.442,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-13",2,0.95,35.44,,0,0.001,20.033,0.0595,0.004,0.0375,337.077,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-14",5,2.98,69.77,,0,0.001,44.468,0.0592,0.01,0.0578,748.593,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-15",4,2.48,65.56,,0,0.001,40.624,0.0595,0.005,0.0308,683.649,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-16",6,4,151.91,,0,0.001,85.095,0.0592,0.01,0.0207,1431.724,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-20",2,0.98,18.5,,0,0.001,12.848,0.0595,0.003,0.0775,215.784,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-27",2,1.03,19.68,,0,0.001,13.293,0.0595,0.003,0.0185,223.934,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Malaga Power",56239,"GT-2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-13",18,17.22,860.44,,0.002,0.001,397.464,0.0592,0.03,0.017,6690.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-14",24,24,1395,,0.003,0.001,626,0.0593,0.037,0.007,10533.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-15",24,24,1424,,0.003,0.001,644.3,0.0591,0.038,0.007,10844.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-16",24,24,1432,,0.003,0.001,652.9,0.0591,0.038,0.007,10984.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-17",24,24,1411,,0.003,0.001,635.8,0.0592,0.038,0.007,10698.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-12",19,18.27,821.08,,0.002,0.001,378.063,0.0594,0.029,0.0173,6360.166,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-13",24,24,1103,,0.003,0.001,503,0.059,0.03,0.007,8466.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-14",24,24,939,,0.002,0.001,446.7,0.0593,0.026,0.007,7515.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-15",1,0.15,1.8,,0,0.001,1.905,0.06,0.001,0.043,32.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-26",2,1.1,29.01,,0,0.001,21.572,0.059,0.007,0.11,363.578,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-27",10,5.86,233.81,,0.001,0.001,118.206,0.0592,0.017,0.0575,1991.388,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-28",24,24,1312,,0.003,0.001,622.7,0.0591,0.033,0.0065,10481.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-29",1,0.17,2.04,,0,0.001,2.074,0.059,0.001,0.031,34.952,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-02",18,17.28,1016.24,,0.003,0.001,514.072,0.0591,0.035,0.0159,8649.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-03",24,24,1380,,0.003,0.001,662.3,0.0592,0.037,0.0066,11146.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-04",24,23.12,1438.08,,0.004,0.001,706.992,0.0592,0.042,0.0084,11894.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-23",19,18.27,1101.35,,0.003,0.001,544.168,0.0591,0.038,0.0167,9158.062,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-24",24,24,1236,,0.003,0.001,583.8,0.0591,0.034,0.007,9828.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-25",24,24,1338,,0.003,0.001,637,0.0593,0.038,0.007,10717,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-26",19,18.25,954.5,,0.002,0.001,455.3,0.0591,0.027,0.007,7666.275,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-13",18,17.27,954.43,,0.002,0.001,442.473,0.0591,0.032,0.0164,7444.89,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-14",24,24,1286,,0.003,0.001,593.2,0.0591,0.035,0.007,9983.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-15",24,24,1275,,0.003,0.001,596.6,0.0591,0.035,0.007,10041.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-16",24,24,1245,,0.003,0.001,581.2,0.0593,0.034,0.007,9782.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-17",24,24,1174,,0.003,0.001,542.7,0.0593,0.032,0.007,9136.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-18",24,24,1306,,0.003,0.001,605.8,0.059,0.036,0.007,10194.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-19",24,24,1263,,0.003,0.001,587,0.0593,0.035,0.007,9870.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-20",24,24,1238,,0.003,0.001,571.8,0.0593,0.034,0.007,9620.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-21",6,5.05,182.1,,0,0.001,90.41,0.0592,0.006,0.0178,1521.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-26",23,22.28,1174.8,,0.003,0.001,556.672,0.0593,0.038,0.0143,9363.18,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-27",24,24,1326,,0.003,0.001,620,0.059,0.037,0.007,10439.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-28",24,24,1313,,0.003,0.001,610.5,0.0591,0.036,0.007,10275.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-29",24,24,1307,,0.003,0.001,609,0.0591,0.036,0.007,10252.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-30",24,24,1297,,0.003,0.001,603.1,0.0594,0.036,0.007,10145.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-07-31",24,24,1269,,0.003,0.001,589.7,0.0593,0.035,0.007,9922.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-01",24,24,1222,,0.003,0.001,563.3,0.0592,0.033,0.007,9483.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-02",24,24,1243,,0.003,0.001,574.2,0.0593,0.034,0.007,9660,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-03",24,24,1255,,0.003,0.001,582.1,0.0592,0.034,0.007,9792.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-04",24,24,1238,,0.003,0.001,575,0.0591,0.034,0.007,9676.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-05",24,23.1,1124.7,,0.003,0.001,518.94,0.0591,0.031,0.009,8731.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-08",2,1.27,41.7,,0,0.001,22.5,0.0595,0.007,0.093,378.652,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-09",24,24,1392,,0.003,0.001,653.8,0.0591,0.039,0.007,11000.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-10",24,24,1323,,0.003,0.001,615.1,0.0592,0.036,0.007,10352.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-11",24,24,1214,,0.003,0.001,550.9,0.0593,0.032,0.007,9269.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-12",24,24,1355,,0.003,0.001,631.1,0.0592,0.037,0.007,10619,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-13",24,24,1378,,0.003,0.001,639,0.0593,0.038,0.0071,10751.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-14",24,24,1502,,0.004,0.001,700.2,0.0591,0.041,0.007,11779.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-15",24,24,1509,,0.004,0.001,708,0.0593,0.042,0.007,11909.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-16",24,24,1449,,0.003,0.001,662.8,0.0593,0.039,0.007,11154.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-17",24,24,1470,,0.003,0.001,674,0.0591,0.04,0.007,11342.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-18",24,24,1380,,0.003,0.001,632.8,0.0593,0.037,0.007,10644.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-19",24,24,1483,,0.003,0.001,676.4,0.0593,0.04,0.007,11380,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-20",24,24,1112,,0.003,0.001,503.9,0.0593,0.03,0.007,8478.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-21",24,24,1315,,0.003,0.001,604,0.0594,0.036,0.007,10160.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-22",24,24,1282,,0.003,0.001,583.3,0.0593,0.034,0.007,9814.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-23",24,24,1302,,0.003,0.001,597.1,0.0592,0.035,0.007,10045.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-24",24,24,1365,,0.003,0.001,625,0.0591,0.037,0.007,10518.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-25",24,24,1307,,0.003,0.001,599.2,0.0591,0.035,0.007,10083.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-26",24,24,1305,,0.003,0.001,605.1,0.0592,0.036,0.007,10179,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-27",24,24,1223,,0.003,0.001,561.3,0.0592,0.033,0.007,9442.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-28",24,24,1289,,0.003,0.001,597.5,0.0593,0.035,0.007,10053.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-29",24,24,1203,,0.003,0.001,553.3,0.0592,0.033,0.007,9309.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-30",24,24,1219,,0.003,0.001,564.4,0.0593,0.033,0.007,9494.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-08-31",24,24,1515,,0.004,0.001,718.9,0.0592,0.043,0.007,12096.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-01",24,24,1374,,0.003,0.001,636,0.0591,0.037,0.007,10703.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-02",24,24,1273,,0.003,0.001,582.3,0.0593,0.034,0.007,9792.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-03",24,24,1370,,0.003,0.001,643.7,0.0592,0.038,0.007,10831.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-04",24,24,1403,,0.003,0.001,660.8,0.0592,0.039,0.007,11117.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-05",24,24,1366,,0.003,0.001,646.1,0.0592,0.038,0.007,10868.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-06",24,24,1341,,0.003,0.001,632.9,0.0592,0.037,0.007,10648.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-07",24,24,1315,,0.003,0.001,609.5,0.0592,0.036,0.007,10256.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-08",24,24,1155,,0.003,0.001,528.2,0.0593,0.031,0.007,8885.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-09",24,24,1333,,0.003,0.001,639,0.0593,0.036,0.0066,10747.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-10",24,24,1168,,0.003,0.001,530.9,0.0592,0.027,0.006,8934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-11",24,24,1150,,0.003,0.001,525.2,0.0592,0.027,0.006,8835.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-12",24,24,1172,,0.003,0.001,542.7,0.0593,0.027,0.006,9129.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-13",24,24,1229,,0.003,0.001,563.4,0.0593,0.028,0.006,9479.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-14",24,24,1256,,0.003,0.001,585.6,0.0593,0.03,0.006,9848.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-15",24,24,1283,,0.003,0.001,596.5,0.0593,0.03,0.006,10035.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-16",24,24,1368,,0.003,0.001,634.2,0.0594,0.032,0.006,10671.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-17",24,24,1317,,0.003,0.001,606.7,0.0592,0.031,0.006,10209.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-18",24,24,1271,,0.003,0.001,582,0.0592,0.029,0.006,9791.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-19",24,24,1221,,0.003,0.001,556.8,0.0593,0.028,0.006,9367,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-20",24,24,1197,,0.003,0.001,555.8,0.0593,0.028,0.006,9350.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-21",24,24,1349,,0.003,0.001,628.5,0.0591,0.031,0.0059,10577,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-22",24,24,1328,,0.003,0.001,610.6,0.0592,0.031,0.006,10273.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-23",24,23.05,1276.15,,0.003,0.001,588.685,0.0592,0.03,0.0083,9904.075,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-28",20,19.27,1011.43,,0.002,0.001,466.711,0.0594,0.028,0.0144,7848.928,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-29",24,24,1278,,0.003,0.001,590.7,0.0593,0.03,0.006,9937.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-09-30",24,24,1308,,0.003,0.001,606.6,0.0591,0.031,0.006,10208.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-01",24,24,1332,,0.003,0.001,617.5,0.0592,0.031,0.006,10391.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-02",24,24,1165,,0.003,0.001,533.5,0.0592,0.027,0.0061,8978.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-03",24,24,1189,,0.003,0.001,543.6,0.0593,0.028,0.006,9147.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-04",24,24,1303,,0.003,0.001,603.2,0.0593,0.03,0.006,10150.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-05",24,24,1354,,0.003,0.001,625,0.0592,0.032,0.006,10518,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-06",24,24,1339,,0.003,0.001,611,0.0593,0.031,0.0061,10281.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-07",24,24,1308,,0.003,0.001,589,0.0593,0.03,0.006,9910.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-08",6,5.05,184.15,,0,0.001,88.035,0.0592,0.005,0.0155,1480.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-10",9,8.77,399.63,,0.001,0.001,196.32,0.0592,0.015,0.0114,3303.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-11",24,24,1172,,0.003,0.001,557,0.0591,0.028,0.006,9373,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-12",24,24,1290,,0.003,0.001,608.1,0.0593,0.031,0.006,10232.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-13",24,24,1456,,0.003,0.001,665.7,0.0591,0.034,0.006,11205.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-14",24,24,1293,,0.003,0.001,590.5,0.0592,0.03,0.006,9938.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-15",18,16.72,808.29,,0.002,0.001,374.886,0.0594,0.021,0.0072,6304.641,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-16",24,24,1280,,0.003,0.001,586.7,0.0592,0.03,0.006,9871.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-17",24,24,1249,,0.003,0.001,569,0.0593,0.029,0.006,9571.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-18",24,24,1225,,0.003,0.001,552.1,0.0591,0.028,0.006,9291.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-19",24,24,1298,,0.003,0.001,589.9,0.0593,0.03,0.006,9924.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-20",24,24,1276,,0.003,0.001,581.7,0.0594,0.03,0.0061,9787.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-21",24,24,1087,,0.003,0.001,495.6,0.0594,0.025,0.006,8337.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-22",24,24,1201,,0.003,0.001,535.4,0.0593,0.027,0.006,9011.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-23",24,23.07,1070.28,,0.002,0.001,485.418,0.0593,0.025,0.0083,8165.987,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-22",4,2.72,85.77,,0,0.001,59.963,0.0595,0.008,0.03,1009.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT001",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-13",20,19.27,988.62,,0.002,0.001,447.303,0.0594,0.029,0.015,7526.63,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-14",24,24,1386,,0.003,0.001,599.5,0.0592,0.03,0.006,10088.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-15",24,24,1398,,0.003,0.001,613.6,0.0592,0.031,0.006,10327,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-16",24,24,1403,,0.003,0.001,620.1,0.0593,0.031,0.006,10433.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-17",24,24,1382,,0.003,0.001,600.8,0.0591,0.03,0.006,10111.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-18",1,0.15,1.8,,0,0.001,1.8,0.059,0.001,0.05,30.405,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-11",21,20.27,1298.62,,0.003,0.001,615.176,0.0591,0.038,0.0153,10349.787,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-12",24,24,1253,,0.003,0.001,553.1,0.059,0.028,0.006,9311.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-13",24,24,1052,,0.002,0.001,465.8,0.0593,0.024,0.006,7837.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-14",24,24,921,,0.002,0.001,423.8,0.0592,0.021,0.006,7131.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-15",1,0.1,0.8,,0,0.001,1.02,0.059,0.001,0.062,17.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-17",20,19.27,1315.89,,0.003,0.001,619.457,0.0592,0.037,0.0147,10425.575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-18",24,24,1615,,0.004,0.001,746.7,0.0591,0.038,0.006,12566.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-19",24,24,1621,,0.004,0.001,746.3,0.0591,0.038,0.006,12557.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-20",24,24,1488,,0.003,0.001,674.4,0.0592,0.034,0.0061,11348.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-21",8,7.13,309.3,,0.001,0.001,143.695,0.0594,0.008,0.0109,2416.581,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-26",9,7.5,276.81,,0.001,0.001,143.209,0.0592,0.014,0.0432,2409.948,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-27",24,24,1402,,0.003,0.001,650.1,0.0591,0.033,0.006,10939.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-28",24,23.07,1243.21,,0.003,0.001,568.069,0.0593,0.029,0.0089,9559.11,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-08",1,0.12,0,,0,0.001,0.336,0.06,0,0.073,5.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-23",17,16.27,1004.89,,0.002,0.001,468.111,0.0591,0.027,0.0131,7875.563,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-24",24,24,1216,,0.003,0.001,552.5,0.0593,0.028,0.006,9295.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-25",24,24,1325,,0.003,0.001,607.5,0.0591,0.031,0.006,10228.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-26",24,24,1322,,0.003,0.001,607,0.059,0.031,0.006,10215.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-27",2,1.17,35.87,,0,0.001,19.138,0.0595,0.002,0.023,322.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-13",21,20.27,1060.16,,0.002,0.001,488.338,0.0591,0.031,0.0135,8218.803,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-14",24,24,1257,,0.003,0.001,560.2,0.0593,0.028,0.006,9426.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-15",24,24,1243,,0.003,0.001,564.5,0.0591,0.029,0.006,9498.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-16",24,24,1221,,0.003,0.001,550.6,0.0592,0.028,0.006,9265,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-17",24,24,1189,,0.003,0.001,523.5,0.0591,0.027,0.006,8813.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-18",24,24,1290,,0.003,0.001,577.6,0.0593,0.029,0.006,9715.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-19",24,24,1248,,0.003,0.001,559.4,0.0593,0.028,0.006,9408.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-20",24,24,1234,,0.003,0.001,546.6,0.0591,0.028,0.006,9198.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-21",6,5.15,186.35,,0,0.001,88.445,0.0593,0.005,0.0118,1490.275,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-25",2,1.28,38.96,,0,0.001,25.62,0.0595,0.007,0.0845,431.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-26",24,24,1274,,0.003,0.001,581.2,0.0592,0.029,0.006,9779.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-27",24,24,1368,,0.003,0.001,608.5,0.0593,0.031,0.006,10237.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-28",24,24,1300,,0.003,0.001,583,0.0592,0.029,0.006,9812.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-29",24,24,1294,,0.003,0.001,582.6,0.0594,0.029,0.006,9798.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-30",24,24,1282,,0.003,0.001,574.9,0.0592,0.029,0.006,9673.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-07-31",24,24,1258,,0.003,0.001,563.7,0.0591,0.028,0.006,9484.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-01",24,24,1215,,0.003,0.001,539.4,0.0593,0.027,0.006,9074.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-02",24,24,1241,,0.003,0.001,551.4,0.0594,0.028,0.006,9271.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-03",24,24,1257,,0.003,0.001,559.7,0.0592,0.028,0.006,9419.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-04",24,24,1226,,0.003,0.001,549.4,0.0592,0.028,0.006,9249.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-05",23,22.07,1064.21,,0.002,0.001,473.269,0.0593,0.025,0.0096,7963.317,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-08",17,16.27,959.62,,0.002,0.001,448.995,0.0591,0.028,0.0158,7556.526,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-09",24,24,1378,,0.003,0.001,625.1,0.0593,0.032,0.006,10515.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-10",24,24,1344,,0.003,0.001,597.9,0.0594,0.03,0.006,10054.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-11",24,24,1205,,0.003,0.001,525.3,0.0592,0.027,0.006,8841.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-12",24,24,1338,,0.003,0.001,602.4,0.0591,0.03,0.006,10138.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-13",24,24,1371,,0.003,0.001,613,0.0593,0.031,0.006,10315.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-14",24,24,1501,,0.003,0.001,674.9,0.0595,0.034,0.006,11350,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-15",24,24,1498,,0.003,0.001,680.2,0.0592,0.034,0.006,11444.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-16",24,24,1458,,0.003,0.001,641.5,0.0592,0.032,0.006,10793.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-17",24,24,1481,,0.003,0.001,652.5,0.0591,0.033,0.006,10977.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-18",24,24,1374,,0.003,0.001,605.5,0.0593,0.031,0.006,10184.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-19",24,24,1502,,0.003,0.001,655.9,0.0591,0.033,0.006,11040.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-20",24,24,1149,,0.002,0.001,494.3,0.0594,0.025,0.006,8316.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-21",24,24,1318,,0.003,0.001,582.2,0.0592,0.029,0.006,9794.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-22",24,24,1274,,0.003,0.001,557.4,0.0593,0.028,0.006,9379.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-23",24,24,1292,,0.003,0.001,570.5,0.0594,0.029,0.006,9596.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-24",24,24,1367,,0.003,0.001,603.2,0.0591,0.03,0.006,10151.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-25",24,24,1307,,0.003,0.001,576,0.0592,0.029,0.006,9690.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-26",24,24,1325,,0.003,0.001,587.4,0.0591,0.03,0.006,9884,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-27",24,24,1217,,0.003,0.001,537.8,0.0592,0.027,0.006,9052.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-28",24,24,1289,,0.003,0.001,574.6,0.0593,0.029,0.006,9665.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-29",24,24,1211,,0.003,0.001,534.8,0.0592,0.027,0.006,9000,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-30",24,23.05,1133.15,,0.003,0.001,506.255,0.0593,0.026,0.0099,8515.875,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-08-31",10,9.27,503.16,,0.001,0.001,220.922,0.0591,0.016,0.0227,3718.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-01",24,24,1374,,0.003,0.001,612.9,0.0592,0.031,0.006,10312.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-02",24,24,1335,,0.003,0.001,579.3,0.0592,0.029,0.006,9745.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-03",24,24,1442,,0.003,0.001,642.9,0.0593,0.033,0.0061,10816.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-04",24,24,1452,,0.003,0.001,652.8,0.0592,0.033,0.006,10986.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-05",24,24,1385,,0.003,0.001,628.4,0.0592,0.032,0.006,10570.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-06",24,24,1350,,0.003,0.001,612.3,0.0593,0.031,0.006,10300.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-07",24,24,1311,,0.003,0.001,584.9,0.0593,0.03,0.006,9839.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-08",24,24,1206,,0.003,0.001,523.3,0.0592,0.027,0.006,8803.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-09",24,24,1359,,0.003,0.001,624.3,0.0591,0.034,0.0064,10506.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-10",24,24,1168,,0.003,0.001,509.7,0.0594,0.03,0.007,8575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-11",24,24,1190,,0.003,0.001,516.6,0.0593,0.031,0.0071,8694.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-12",24,24,1199,,0.003,0.001,530.3,0.0592,0.031,0.007,8923.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-13",24,24,1230,,0.003,0.001,541.6,0.0593,0.031,0.0069,9111.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-14",24,24,1270,,0.003,0.001,568.6,0.0593,0.034,0.0071,9567.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-15",24,24,1308,,0.003,0.001,581.7,0.0591,0.034,0.007,9787.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-16",24,24,1420,,0.003,0.001,627.6,0.0592,0.037,0.007,10562.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-17",24,24,1401,,0.003,0.001,611.1,0.0591,0.036,0.007,10282,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-18",24,24,1314,,0.003,0.001,573.3,0.0593,0.034,0.007,9644.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-19",24,24,1253,,0.003,0.001,545,0.0593,0.032,0.0071,9168.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-20",24,24,1210,,0.003,0.001,539.5,0.0593,0.032,0.007,9077.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-21",24,24,1382,,0.003,0.001,616.3,0.0593,0.036,0.007,10372.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-22",24,24,1356,,0.003,0.001,597.2,0.0593,0.035,0.007,10048.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-23",24,24,1348,,0.003,0.001,595.6,0.0594,0.035,0.007,10016.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-24",24,24,1362,,0.003,0.001,609.1,0.0593,0.036,0.007,10249.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-25",24,24,1197,,0.003,0.001,529.4,0.0593,0.032,0.0071,8907.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-26",24,24,1030,,0.002,0.001,473.4,0.0593,0.028,0.007,7964.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-27",24,24,1097,,0.002,0.001,495.2,0.0593,0.029,0.007,8329.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-28",24,24,1209,,0.003,0.001,540.1,0.0592,0.032,0.007,9089.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-29",24,24,1300,,0.003,0.001,575.7,0.0593,0.034,0.0071,9685.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-09-30",24,24,1300,,0.003,0.001,581.4,0.0593,0.034,0.007,9783.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-01",24,24,1364,,0.003,0.001,605.7,0.0593,0.036,0.007,10189.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-02",24,24,1181,,0.003,0.001,517.8,0.0591,0.031,0.007,8715.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-03",24,24,1208,,0.003,0.001,529.8,0.0593,0.031,0.007,8913.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-04",24,24,1333,,0.003,0.001,589.6,0.0591,0.035,0.0071,9926.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-05",24,24,1369,,0.003,0.001,607.3,0.0591,0.036,0.007,10223.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-06",24,24,1338,,0.003,0.001,587.8,0.0592,0.035,0.0071,9891.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-07",24,24,1324,,0.003,0.001,570.4,0.0592,0.034,0.007,9596.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-08",24,24,1305,,0.003,0.001,590.1,0.0593,0.035,0.0071,9926.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-09",24,24,1356,,0.003,0.001,606.7,0.0591,0.036,0.007,10210.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-10",14,13.88,678.52,,0.002,0.001,309.04,0.0592,0.018,0.007,5201.036,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-13",20,16.46,909.04,,0.002,0.001,396.434,0.0594,0.03,0.0313,6669.658,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-14",24,24,1341,,0.003,0.001,583.1,0.0592,0.035,0.0071,9812.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-15",24,24,1407,,0.003,0.001,626.8,0.0593,0.037,0.007,10546,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-16",24,24,1367,,0.003,0.001,590.3,0.0591,0.035,0.007,9938.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-17",24,24,1305,,0.003,0.001,563.2,0.0592,0.034,0.0071,9478.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-18",24,24,1285,,0.003,0.001,547.8,0.0592,0.032,0.007,9221.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-19",24,24,1338,,0.003,0.001,580,0.0592,0.034,0.007,9761,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-20",24,24,1321,,0.003,0.001,573.1,0.059,0.034,0.007,9647.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-21",24,24,1132,,0.002,0.001,488.9,0.0593,0.029,0.007,8223.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-22",24,24,1210,,0.003,0.001,516.9,0.0591,0.03,0.007,8699.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-23",24,24,1184,,0.003,0.001,505.9,0.0596,0.03,0.007,8505.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-24",24,24,1224,,0.003,0.001,550.9,0.0593,0.033,0.0071,9269.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-25",24,24,1325,,0.003,0.001,592.8,0.0592,0.035,0.0071,9975.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-26",24,24,1457,,0.003,0.001,665.1,0.0591,0.04,0.0071,11192,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-27",24,24,1274,,0.003,0.001,565.6,0.0592,0.033,0.007,9519.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-28",24,24,1271,,0.003,0.001,557.6,0.0591,0.033,0.007,9386.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-29",24,24,1304,,0.003,0.001,583.8,0.0592,0.035,0.007,9824.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-30",24,24,1338,,0.003,0.001,596.1,0.0593,0.035,0.007,10028.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-10-31",24,24,1265,,0.003,0.001,564.8,0.0592,0.033,0.007,9506.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-01",24,24,1215,,0.003,0.001,563.2,0.0593,0.034,0.0071,9474.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-02",24,24,1404,,0.003,0.001,651.8,0.0591,0.039,0.007,10971.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-03",24,24,1428,,0.003,0.001,659.4,0.0592,0.039,0.007,11098.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-04",24,24,1241,,0.003,0.001,564,0.0592,0.033,0.007,9491.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-05",24,24,1266,,0.003,0.001,576.3,0.0594,0.034,0.007,9691.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-06",24,24,1155,,0.003,0.001,520.4,0.0593,0.031,0.007,8757.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-07",24,24,1143,,0.003,0.001,518.1,0.0593,0.031,0.007,8717.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-08",24,24,1128,,0.003,0.001,514,0.0593,0.03,0.007,8648.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-09",24,24,1242,,0.003,0.001,551.1,0.0591,0.032,0.007,9275.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-10",24,24,1276,,0.003,0.001,569.3,0.0593,0.034,0.007,9577.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-11",24,24,1153,,0.003,0.001,523.3,0.0593,0.031,0.007,8806.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-12",24,24,1122,,0.003,0.001,513.8,0.0592,0.03,0.007,8646.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-13",24,24,1205,,0.003,0.001,543.7,0.0594,0.032,0.007,9148.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-14",24,24,1160,,0.003,0.001,526.2,0.0592,0.031,0.007,8860,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-15",24,24,1225,,0.003,0.001,550.5,0.0594,0.032,0.007,9260,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-16",24,24,1217,,0.003,0.001,549.2,0.0593,0.033,0.0071,9241,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-17",24,24,1170,,0.003,0.001,527.1,0.0593,0.031,0.007,8865.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-18",24,24,1181,,0.003,0.001,533.9,0.0592,0.032,0.007,8985.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-19",24,24,1165,,0.003,0.001,528.6,0.0592,0.031,0.007,8895.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-20",24,24,1253,,0.003,0.001,559.2,0.0592,0.034,0.0071,9411,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-21",24,24,1245,,0.003,0.001,557.1,0.0594,0.033,0.007,9371.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-22",24,24,1257,,0.003,0.001,571,0.0592,0.034,0.007,9607,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-23",24,24,1210,,0.003,0.001,540.7,0.0591,0.032,0.007,9099.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-24",24,24,1225,,0.003,0.001,545.1,0.0594,0.032,0.007,9169.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-25",24,24,1210,,0.003,0.001,545.3,0.0593,0.032,0.0071,9174.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-26",1,0.07,0.21,,0,0.001,0.469,0.059,0,0.086,7.903,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-22",4,2.85,88.85,,0,0.001,59.31,0.0595,0.013,0.0523,997.865,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Roseville Energy Park",56298,"CT002",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-17",19,17.99,3366.54,,0.008,0.001,1564.031,0.059,0.144,0.0153,26319.796,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-18",7,6.18,1215.1,,0.003,0.001,532.34,0.059,0.054,0.0169,8956.768,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-19",3,2.45,401.5,,0.001,0.001,188.402,0.059,0.033,0.03,3170.23,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-20",11,10.53,1969.44,,0.004,0.001,877.325,0.059,0.09,0.0195,14764.044,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-21",7,6.23,1148.7,,0.003,0.001,510.619,0.059,0.022,0.0054,8592.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-25",12,10.19,1810.45,,0.004,0.001,850.534,0.059,0.09,0.0147,14311.587,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-08",3,1.47,115.32,,0,0.001,78.745,0.0593,0.089,0.1,1325.015,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-09",1,0.05,0.05,,0,0.001,0.565,0.059,0,0,9.53,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-10",1,0.43,8.17,,0,0.001,15.394,0.06,0.016,0.126,258.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-17",4,3.85,383.55,,0.001,0.001,233.26,0.059,0.074,0.0473,3925.735,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-18",20,19.45,3805.2,,0.008,0.001,1675.85,0.059,0.094,0.0071,28199.215,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-19",24,24,4670,,0.01,0.001,2038.1,0.059,0.102,0.006,34292.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-20",9,8.32,1517.88,,0.003,0.001,674.288,0.059,0.034,0.0061,11345.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-25",11,10.57,2647.91,,0.006,0.001,1118.275,0.059,0.095,0.0171,18816.159,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-26",24,24,5687,,0.012,0.001,2390.8,0.059,0.12,0.006,40227.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-27",17,16.5,4316.98,,0.009,0.001,1805.039,0.059,0.104,0.0073,30373.151,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-28",24,23.55,5312.4,,0.011,0.001,2246.975,0.059,0.112,0.006,37813.27,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-02",9,8.67,2140.35,,0.005,0.001,917.91,0.059,0.086,0.0159,15446.049,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-03",11,9.84,2620.14,,0.006,0.001,1112.366,0.059,0.081,0.0127,18718.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-04",9,8.24,2088.59,,0.004,0.001,891.533,0.059,0.068,0.0146,14998.955,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-09",7,6.52,1597.22,,0.004,0.001,697.594,0.059,0.077,0.0219,11738.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-10",8,7.2,1897.62,,0.004,0.001,804.316,0.059,0.06,0.0101,13534.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-11",7,5.67,1469.4,,0.003,0.001,632.926,0.059,0.054,0.0184,10649.649,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-22",11,9.63,2267.4,,0.005,0.001,957.199,0.059,0.088,0.0155,16106.209,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-07",18,16.93,3968.6,,0.009,0.001,1748.885,0.059,0.132,0.0142,29428.465,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-08",17,16.55,4615.31,,0.01,0.001,1970.473,0.059,0.103,0.0072,33156.228,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-09",6,5.7,1375.12,,0.003,0.001,584.016,0.059,0.045,0.012,9826.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-10",10,9.48,2336.56,,0.005,0.001,983.876,0.059,0.064,0.0129,16552.664,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-11",10,9.12,2159.98,,0.005,0.001,917.419,0.059,0.061,0.0089,15436.598,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-12",10,9.67,2450.75,,0.005,0.001,1031.107,0.059,0.068,0.0105,17350.175,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-13",24,23.15,5123.2,,0.011,0.001,2189.105,0.059,0.101,0.0056,36838.915,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-17",7,6.44,1424.98,,0.003,0.001,617.078,0.059,0.071,0.0204,10382.846,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-23",2,0.23,0.23,,0,0.001,6.705,0.0595,0.004,0.0535,112.694,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-27",14,13.25,2932.1,,0.007,0.001,1330.865,0.059,0.118,0.0189,22392.755,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-28",11,9.37,2232.34,,0.005,0.001,974.18,0.059,0.072,0.0127,16392.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-29",14,13.28,3358.56,,0.007,0.001,1430.108,0.059,0.092,0.0123,24065,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-30",11,10.13,2600.94,,0.006,0.001,1093.977,0.059,0.068,0.0085,18406.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-07-31",10,9.47,2319.5,,0.005,0.001,976.256,0.059,0.063,0.009,16428.523,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-01",11,9.56,2249.98,,0.005,0.001,952.575,0.059,0.066,0.0085,16027.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-02",3,2.76,483.28,,0.001,0.001,218.642,0.059,0.03,0.017,3679.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-03",4,2.71,502.83,,0.001,0.001,227.343,0.059,0.033,0.022,3826.779,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-10",8,7.63,1241.93,,0.003,0.001,619.691,0.059,0.081,0.0233,10428.73,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-11",21,20.27,4318.13,,0.009,0.001,1873.123,0.059,0.101,0.0076,31520.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-12",24,24,5835,,0.012,0.001,2471,0.059,0.113,0.0055,41582.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-13",24,24,6193,,0.013,0.001,2605.7,0.059,0.122,0.0055,43845.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-14",24,24,6506,,0.014,0.001,2699.7,0.059,0.124,0.0055,45426.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-15",24,24,6419,,0.013,0.001,2670.1,0.059,0.127,0.0057,44930.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-16",24,24,6532,,0.014,0.001,2708.6,0.059,0.129,0.0057,45579.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-17",24,24,6604,,0.014,0.001,2739.8,0.059,0.132,0.0058,46100.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-18",24,24,6449,,0.013,0.001,2669.7,0.059,0.13,0.0058,44928.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-19",24,24,6917,,0.014,0.001,2869,0.059,0.136,0.0056,48278.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-20",24,24,6144,,0.013,0.001,2527.1,0.059,0.121,0.0057,42526.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-21",24,23.2,5772.6,,0.012,0.001,2396.22,0.059,0.114,0.0058,40320.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-22",16,15.15,3836.72,,0.008,0.001,1646.199,0.059,0.095,0.0093,27702.843,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-23",18,17.25,4288.25,,0.009,0.001,1825.15,0.059,0.104,0.0101,30716.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-24",24,24,6189,,0.013,0.001,2556.8,0.059,0.124,0.0058,43024.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-25",24,24,5700,,0.012,0.001,2365.9,0.059,0.113,0.0057,39810,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-26",24,24,5378,,0.012,0.001,2281.3,0.059,0.104,0.0054,38385.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-27",24,24,6172,,0.013,0.001,2569.7,0.059,0.119,0.0055,43242.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-28",24,24,5326,,0.011,0.001,2257.5,0.059,0.105,0.0055,37989.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-29",24,24,5613,,0.012,0.001,2377.4,0.059,0.105,0.0053,40004.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-30",24,24,5425,,0.012,0.001,2305.6,0.059,0.103,0.0053,38796.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-08-31",24,24,5095,,0.011,0.001,2179.5,0.059,0.095,0.0052,36673.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-01",24,24,5008,,0.011,0.001,2145.9,0.059,0.096,0.0053,36103,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-02",1,0.4,47.6,,0,0.001,28.36,0.059,0.001,0.006,477.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-03",14,13.75,3482.25,,0.007,0.001,1461.85,0.059,0.098,0.0102,24597.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-04",24,24,5629,,0.012,0.001,2358.2,0.059,0.119,0.006,39679.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-05",24,24,5790,,0.012,0.001,2424.7,0.059,0.122,0.006,40799.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-06",24,24,5928,,0.013,0.001,2479.6,0.059,0.125,0.006,41723.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-07",24,24,6242,,0.013,0.001,2579.5,0.059,0.131,0.006,43406.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-08",24,24,6030,,0.013,0.001,2488.8,0.059,0.114,0.0055,41877.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-09",13,12.21,2624.62,,0.006,0.001,1115.043,0.059,0.072,0.0087,18765.401,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-10",13,11.8,2383.68,,0.005,0.001,1058.427,0.059,0.069,0.0096,17813.824,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-16",12,10.94,2234.52,,0.005,0.001,1013.586,0.059,0.097,0.0172,17055.394,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-18",10,8.47,1793.87,,0.004,0.001,819.794,0.059,0.089,0.0238,13792.966,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-19",9,8.13,1953.66,,0.004,0.001,860.742,0.059,0.068,0.0168,14485.227,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-26",6,5.86,814.86,,0.002,0.001,419.104,0.059,0.076,0.0297,7051.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-27",13,12.09,2667.22,,0.006,0.001,1175.67,0.059,0.098,0.0122,19781.793,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-28",16,15.2,3717.21,,0.008,0.001,1589.996,0.059,0.097,0.0083,26753.424,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-29",19,18.23,4622.81,,0.01,0.001,1972.497,0.059,0.115,0.0077,33190.026,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-09-30",18,16.97,4353.34,,0.009,0.001,1859.048,0.059,0.11,0.0085,31286.258,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-01",20,18.81,4602.75,,0.01,0.001,1954.089,0.059,0.11,0.0073,32883.212,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-02",17,16.32,4109.37,,0.009,0.001,1746.221,0.059,0.106,0.0092,29384.094,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-03",10,9.48,2244.17,,0.005,0.001,942.63,0.059,0.067,0.0097,15861.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-05",8,7.02,1728.58,,0.004,0.001,747.57,0.059,0.076,0.0233,12581.142,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-06",11,9.93,2597.72,,0.006,0.001,1094.67,0.059,0.078,0.0139,18418.055,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-12",12,12,2801,,0.006,0.001,1179.6,0.059,0.099,0.0122,19847.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-13",24,24,6193,,0.013,0.001,2604.9,0.059,0.141,0.0065,43836.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-14",24,24,6168,,0.013,0.001,2573.5,0.059,0.134,0.0062,43306.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-15",24,24,6380,,0.013,0.001,2649.7,0.059,0.138,0.0062,44585.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-16",24,24,6165,,0.013,0.001,2570.8,0.059,0.133,0.0062,43261.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-17",24,24,6128,,0.013,0.001,2551.7,0.059,0.132,0.0062,42938.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-18",23,22.17,6054.41,,0.013,0.001,2575.669,0.059,0.139,0.0065,43341.677,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-19",20,19.98,5094,,0.011,0.001,2178.844,0.059,0.121,0.0069,36665.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-20",24,24,6295,,0.013,0.001,2631.1,0.059,0.135,0.0061,44272.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-21",24,24,6488,,0.014,0.001,2684,0.059,0.136,0.006,45163.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-22",24,22.79,5761.12,,0.012,0.001,2403.006,0.059,0.126,0.0061,40435.839,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-23",23,22.82,5760.38,,0.012,0.001,2381.062,0.059,0.124,0.0062,40066.882,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-25",11,10.32,2453.64,,0.005,0.001,1077.344,0.059,0.103,0.0225,18124.98,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-26",19,18.75,4881.3,,0.01,0.001,2031.04,0.059,0.118,0.0073,34176.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-27",24,24,6138,,0.013,0.001,2543.8,0.059,0.131,0.0061,42803.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-28",24,24,6150,,0.013,0.001,2529.6,0.059,0.128,0.006,42566.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-29",1,0.42,52.5,,0,0.001,30.198,0.059,0.002,0.008,507.99,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-01",8,7.04,1762.38,,0.004,0.001,755.51,0.059,0.077,0.0181,12713.916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-02",11,10.68,2849.12,,0.006,0.001,1189.156,0.059,0.081,0.011,20009.608,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-03",24,24,6540,,0.014,0.001,2691.7,0.059,0.139,0.0061,45294.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-04",24,24,6484,,0.014,0.001,2684.1,0.059,0.139,0.0062,45169.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-05",24,24,6655,,0.014,0.001,2735,0.059,0.136,0.0059,46020.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-06",22,21.22,5287.56,,0.011,0.001,2190.452,0.059,0.111,0.0061,36859.222,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-09",11,10.18,2594.08,,0.005,0.001,1086.378,0.0591,0.102,0.0203,18279.636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-10",24,24,6205,,0.013,0.001,2558.8,0.059,0.132,0.0061,43056.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-11",24,24,6116,,0.013,0.001,2532.9,0.059,0.13,0.0061,42621.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-12",22,21.72,5503.68,,0.012,0.001,2289.704,0.059,0.117,0.0061,38525.516,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-19",6,3.17,6.09,,0.001,0.001,104.41,0.059,0.049,0.0553,1757.566,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-23",11,10.12,1981.08,,0.005,0.001,918.592,0.059,0.088,0.0165,15457.416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-02",13,12.47,2740.24,,0.006,0.001,1236.916,0.059,0.122,0.0196,20813.137,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-03",10,9.82,2674.4,,0.006,0.001,1125.18,0.059,0.075,0.0103,18934.492,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-04",24,24,6588,,0.014,0.001,2727.9,0.059,0.137,0.006,45902.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-05",24,24,6457,,0.013,0.001,2667,0.059,0.133,0.0059,44875.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-06",24,24,6314,,0.013,0.001,2613.1,0.059,0.125,0.0057,43969.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-07",24,24,6323,,0.013,0.001,2620.9,0.059,0.131,0.0059,44101.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-08",24,24,6238,,0.013,0.001,2573.3,0.059,0.129,0.006,43303.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-09",22,20.42,4980.68,,0.011,0.001,2090.217,0.059,0.107,0.0064,35168.602,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-10",22,21.33,5712.21,,0.012,0.001,2402.952,0.059,0.128,0.0072,40433.143,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-11",24,24,6612,,0.014,0.001,2734.1,0.059,0.138,0.006,46008.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-12",24,24,6336,,0.013,0.001,2623.1,0.059,0.13,0.0059,44138.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-13",21,20.5,4592.49,,0.01,0.001,2018.869,0.059,0.104,0.0067,33971.839,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-14",24,24,6580,,0.014,0.001,2711.7,0.059,0.136,0.006,45632,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-15",24,24,6829,,0.014,0.001,2815.8,0.059,0.137,0.0058,47386.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-16",24,24,6826,,0.014,0.001,2820.1,0.059,0.138,0.0058,47452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-17",24,24,6297,,0.013,0.001,2593.2,0.059,0.13,0.006,43637.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-18",24,23.87,6100.44,,0.013,0.001,2535.905,0.059,0.126,0.0059,42667.813,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-19",1,0.4,0.8,,0,0.001,12.52,0.059,0.011,0.102,210.92,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-20",5,4.31,341.78,,0.001,0.001,242.795,0.059,0.066,0.0462,4086.543,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-21",24,24,6218,,0.013,0.001,2595.7,0.059,0.13,0.006,43679.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-22",6,4.47,975.43,,0.002,0.001,444.216,0.059,0.057,0.0305,7475.699,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-23",24,23.17,6153.09,,0.013,0.001,2579.86,0.059,0.13,0.0061,43408.656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-28",24,23.05,5877.05,,0.013,0.001,2508.6,0.059,0.188,0.0132,42212.145,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-29",24,24,6317,,0.013,0.001,2611.6,0.059,0.131,0.006,43946.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-30",24,24,6125,,0.013,0.001,2540.1,0.059,0.127,0.006,42744.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT1",,"2020-12-31",1,0.5,80.5,,0,0.001,37.25,0.059,0.002,0.007,627,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-17",5,3.55,677.84,,0.002,0.001,310.001,0.059,0.063,0.0272,5216.105,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-18",17,15.92,3238.34,,0.007,0.001,1446.216,0.059,0.091,0.0084,24334.348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-19",16,14.72,2939.12,,0.007,0.001,1314.806,0.059,0.077,0.0089,22122.866,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-20",15,13.66,2869.62,,0.007,0.001,1299.19,0.059,0.134,0.0183,21860.879,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-25",7,6.35,1159.85,,0.003,0.001,520.045,0.059,0.068,0.0227,8752.145,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-08",8,6.73,974.37,,0.003,0.001,523.694,0.059,0.082,0.0284,8812.988,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-20",10,8.94,1792.66,,0.004,0.001,827.744,0.059,0.078,0.0176,13929.64,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-24",10,9.3,1796.2,,0.004,0.001,834.03,0.059,0.093,0.0181,14032.74,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-25",14,13.56,3269.82,,0.007,0.001,1422.45,0.059,0.089,0.0102,23935.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-26",17,16.83,4176.62,,0.009,0.001,1756.197,0.059,0.1,0.0075,29551.621,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-27",20,18.67,4745.22,,0.01,0.001,2019.292,0.059,0.112,0.0078,33983.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-28",15,13.89,3362.99,,0.007,0.001,1420.206,0.059,0.084,0.0087,23896.671,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-29",4,3.77,631.81,,0.002,0.001,310.986,0.059,0.051,0.03,5233.032,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-30",3,2.75,557.75,,0.001,0.001,247.375,0.059,0.013,0.0063,4163.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-02",15,13.74,3051.19,,0.007,0.001,1355.618,0.059,0.113,0.0164,22811.389,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-03",14,12.93,3372,,0.007,0.001,1455.804,0.059,0.088,0.0116,24495.334,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-04",13,11.36,2823.48,,0.006,0.001,1232.052,0.0591,0.077,0.0125,20733.464,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-09",13,11.15,2355.55,,0.005,0.001,1078.91,0.059,0.102,0.0148,18153.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-10",11,10.32,2642.36,,0.006,0.001,1137.53,0.059,0.066,0.0091,19140.716,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-11",10,9.35,2356.25,,0.005,0.001,1023.975,0.059,0.061,0.0121,17231.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-22",16,15.11,3319.46,,0.007,0.001,1471.413,0.059,0.117,0.0134,24758.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-09",22,21.27,5295.62,,0.012,0.001,2285.522,0.059,0.146,0.0108,38455.162,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-10",24,24,6202,,0.013,0.001,2635.4,0.059,0.149,0.0068,44345,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-11",18,17.1,4246.8,,0.009,0.001,1827.715,0.059,0.109,0.0082,30750.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-12",24,23.93,5582.4,,0.012,0.001,2383.963,0.059,0.132,0.0066,40111.272,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-13",9,8.5,1956.2,,0.004,0.001,831.144,0.059,0.067,0.0107,13985.536,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-17",11,10,2042.12,,0.005,0.001,933.015,0.059,0.101,0.0194,15698.517,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-19",7,6.27,1053.27,,0.003,0.001,512.984,0.059,0.083,0.0224,8630.515,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-20",7,6.05,1367.7,,0.003,0.001,611.425,0.059,0.056,0.015,10289.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-21",6,4.53,861.02,,0.002,0.001,415.087,0.059,0.052,0.026,6987.041,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-22",10,8.5,1729,,0.004,0.001,768.775,0.0591,0.06,0.012,12935.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-27",10,7.98,1898.68,,0.004,0.001,823.474,0.059,0.087,0.0193,13857.435,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-28",9,7.75,1882.1,,0.004,0.001,801.87,0.0591,0.07,0.0123,13495.235,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-29",12,11.2,2894.6,,0.006,0.001,1216.48,0.059,0.093,0.0121,20471.14,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-30",23,22.43,5615.21,,0.012,0.001,2385.843,0.059,0.144,0.0072,40146.398,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-07-31",14,12.47,2990.39,,0.007,0.001,1291.159,0.059,0.099,0.0138,21724.666,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-01",14,12.63,2890.79,,0.006,0.001,1256.619,0.059,0.097,0.0143,21147.771,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-02",6,4.79,931.56,,0.002,0.001,439.604,0.059,0.051,0.025,7397.379,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-03",6,5,1034.78,,0.002,0.001,494.25,0.059,0.058,0.0275,8317.756,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-10",4,2.97,513.2,,0.001,0.001,249.113,0.059,0.066,0.05,4191.315,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-11",9,7.96,1802.91,,0.004,0.001,776.803,0.059,0.069,0.0108,13069.938,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-12",10,9.85,2392.85,,0.005,0.001,1018.436,0.059,0.079,0.0108,17138.183,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-13",12,11.87,3124.05,,0.007,0.001,1311.359,0.059,0.095,0.01,22068.172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-14",24,24,6506,,0.014,0.001,2707.8,0.059,0.158,0.007,45561.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-15",24,24,6419,,0.013,0.001,2673.8,0.059,0.157,0.007,44990.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-16",24,24,6525,,0.014,0.001,2715.7,0.059,0.16,0.007,45698.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-17",24,24,6597,,0.014,0.001,2745.5,0.059,0.16,0.0069,46200.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-18",24,24,6454,,0.014,0.001,2680.2,0.059,0.158,0.007,45099.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-19",24,24,6918,,0.015,0.001,2879.7,0.059,0.167,0.0069,48457.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-20",24,24,6169,,0.013,0.001,2548.2,0.059,0.151,0.007,42875.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-21",24,23.65,5899.6,,0.012,0.001,2457.255,0.059,0.143,0.007,41348.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-22",13,11.35,2882.3,,0.006,0.001,1220.527,0.059,0.09,0.0126,20539.806,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-23",16,15.03,3857,,0.008,0.001,1619.909,0.059,0.113,0.0083,27256.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-24",24,24,6195,,0.013,0.001,2572.2,0.059,0.148,0.0068,43279.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-25",24,24,5741,,0.012,0.001,2395,0.059,0.14,0.007,40297,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-26",16,13.91,3134.17,,0.007,0.001,1348.197,0.059,0.095,0.0082,22683.539,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-27",21,20.07,5348.07,,0.011,0.001,2226.677,0.059,0.139,0.0072,37465.441,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-28",12,9.99,2398.5,,0.005,0.001,1029.298,0.059,0.08,0.0102,17318.027,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-29",10,9.02,1943,,0.004,0.001,829.318,0.0591,0.075,0.0153,13958.458,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-30",1,0.42,53.76,,0,0.001,30.702,0.059,0.002,0.008,516.642,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-08-31",9,8.15,1546.3,,0.003,0.001,671.585,0.059,0.083,0.0193,11301.055,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-01",10,8.6,1630.88,,0.004,0.001,718.112,0.059,0.067,0.0134,12081.554,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-02",24,24,5238,,0.011,0.001,2257.9,0.059,0.131,0.0069,37997.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-03",24,24,5749,,0.012,0.001,2443.1,0.059,0.145,0.007,41113.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-04",24,24,5798,,0.012,0.001,2429.5,0.059,0.142,0.007,40877.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-05",24,24,5954,,0.013,0.001,2488.5,0.059,0.147,0.007,41870.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-06",24,24,6069,,0.013,0.001,2536.4,0.059,0.148,0.007,42681.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-07",24,24,6248,,0.013,0.001,2592.6,0.059,0.153,0.007,43624.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-08",24,24,6073,,0.013,0.001,2516.7,0.059,0.148,0.007,42349,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-09",22,21.92,4971.36,,0.011,0.001,2105.292,0.059,0.126,0.0071,35426.236,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-16",8,7.53,1736.68,,0.004,0.001,749.1,0.059,0.091,0.0199,12604.047,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-18",6,5.32,1223.44,,0.003,0.001,533.532,0.059,0.071,0.0288,8978.556,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-19",8,6.7,1582.98,,0.003,0.001,685.469,0.059,0.063,0.0189,11533.324,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-27",10,9.36,2157.29,,0.005,0.001,920.48,0.059,0.106,0.0198,15491.255,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-28",13,12.95,3275.55,,0.007,0.001,1370.705,0.059,0.106,0.0099,23068.65,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-29",16,15.63,4073.79,,0.009,0.001,1712.906,0.059,0.12,0.0098,28822.378,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-09-30",15,14.69,3871.69,,0.008,0.001,1623.906,0.059,0.116,0.0102,27326.405,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-01",16,15.48,3866.56,,0.008,0.001,1619.14,0.059,0.109,0.0088,27245.076,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-02",13,11.67,3076.92,,0.007,0.001,1291.825,0.059,0.095,0.0132,21735.705,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-03",13,11.95,2761.05,,0.006,0.001,1187.865,0.059,0.095,0.0115,19989.755,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-05",12,11.12,2567.46,,0.006,0.001,1146.142,0.059,0.12,0.017,19283.738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-06",14,12.74,3358.53,,0.007,0.001,1443.519,0.059,0.115,0.0134,24289.103,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-11",13,12.82,2792.8,,0.006,0.001,1232.042,0.059,0.133,0.0196,20731.934,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-12",21,20.28,4916.08,,0.01,0.001,2071.232,0.059,0.123,0.0071,34854.552,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-13",11,11,2720,,0.006,0.001,1153.8,0.059,0.097,0.0111,19416,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-14",24,24,6173,,0.013,0.001,2578.5,0.059,0.153,0.0071,43388.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-15",24,24,6393,,0.013,0.001,2659.2,0.059,0.16,0.0072,44749.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-16",24,24,6189,,0.013,0.001,2585.5,0.059,0.155,0.0071,43506.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-17",24,24,6151,,0.013,0.001,2569.1,0.059,0.2,0.0095,43230.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-18",10,8.88,2244.23,,0.005,0.001,966.234,0.059,0.08,0.0165,16259.691,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-19",16,14.58,3775.04,,0.008,0.001,1591.068,0.059,0.111,0.0091,26771.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-20",24,24,6440,,0.013,0.001,2624.9,0.059,0.159,0.0072,44172.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-21",24,24,6460,,0.013,0.001,2664.3,0.059,0.16,0.0072,44832.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-22",24,24,6244,,0.013,0.001,2616.3,0.059,0.156,0.0071,44024.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-23",23,22.47,5766.54,,0.012,0.001,2413.934,0.059,0.143,0.0071,40619.705,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-26",14,13.47,3365.09,,0.007,0.001,1451.077,0.059,0.147,0.0219,24419.29,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-27",20,19,4966.98,,0.011,0.001,2085.508,0.059,0.13,0.008,35091.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-28",24,24,6249,,0.013,0.001,2613.4,0.059,0.154,0.007,43976.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-29",22,21.32,5474.68,,0.012,0.001,2315.172,0.059,0.137,0.0071,38955.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-30",9,8.05,1946.5,,0.004,0.001,856.675,0.059,0.081,0.0153,14416.695,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-10-31",9,8.07,1980.62,,0.004,0.001,865.525,0.059,0.081,0.0148,14563.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-01",11,10.43,2477.58,,0.005,0.001,1077.134,0.059,0.091,0.0129,18125.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-02",20,19.4,5269.6,,0.011,0.001,2236.6,0.059,0.141,0.0088,37634.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-03",24,24,6546,,0.014,0.001,2702.6,0.059,0.163,0.0072,45479.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-04",24,24,6511,,0.014,0.001,2721.4,0.059,0.159,0.007,45795.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-05",24,24,6699,,0.014,0.001,2795.3,0.059,0.163,0.007,47038.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-06",22,21.7,5408.7,,0.011,0.001,2257.86,0.059,0.134,0.0071,37991.31,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-08",11,10.92,2594.36,,0.006,0.001,1150.52,0.059,0.122,0.0176,19357.172,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-09",24,24,6380,,0.014,0.001,2710.4,0.059,0.164,0.0072,45612.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-10",24,24,6270,,0.013,0.001,2633,0.059,0.157,0.0071,44304.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-11",24,24,6127,,0.013,0.001,2546.2,0.059,0.154,0.0072,42841.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-12",23,22.2,5633.2,,0.012,0.001,2351.56,0.059,0.142,0.0073,39568.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-20",6,3.7,5.55,,0.001,0.001,124.36,0.0592,0.042,0.0325,2093.495,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-24",9,8.75,1986.6,,0.004,0.001,889.185,0.059,0.081,0.0148,14960.645,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-02",8,7.23,1760.28,,0.004,0.001,762.515,0.059,0.104,0.0276,12832.611,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-03",13,12.7,3300.3,,0.007,0.001,1413.88,0.059,0.114,0.0131,23795.71,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-04",24,24,6592,,0.014,0.001,2742.5,0.059,0.162,0.007,46146.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-05",24,24,6469,,0.014,0.001,2680.2,0.059,0.155,0.0069,45098.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-06",24,24,6410,,0.013,0.001,2662.8,0.059,0.15,0.0067,44803.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-07",24,24,6358,,0.013,0.001,2642.4,0.059,0.152,0.0068,44461.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-08",24,24,6245,,0.013,0.001,2588.5,0.059,0.152,0.007,43553.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-09",24,23.83,6010.17,,0.013,0.001,2514.006,0.059,0.148,0.007,42305.035,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-10",18,18,4867,,0.01,0.001,2029.5,0.059,0.132,0.0081,34151.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-11",24,24,6619,,0.014,0.001,2746.5,0.059,0.159,0.0069,46217.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-12",24,24,6346,,0.013,0.001,2636.8,0.059,0.151,0.0068,44368.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-13",24,24,5981,,0.013,0.001,2623.1,0.059,0.154,0.007,44141.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-14",24,24,6522,,0.014,0.001,2702.7,0.059,0.155,0.0068,45476.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-15",24,24,6786,,0.014,0.001,2808.4,0.059,0.162,0.0069,47260.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-16",24,24,6823,,0.014,0.001,2828.2,0.059,0.164,0.0069,47585.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-17",24,24,6269,,0.013,0.001,2592.7,0.059,0.153,0.007,43628.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-18",24,23.47,5972.01,,0.013,0.001,2496.816,0.059,0.145,0.007,42014.205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-19",1,0.7,2.8,,0,0.001,24.36,0.059,0.03,0.148,409.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-20",2,0.95,3.24,,0,0.001,33.787,0.059,0.021,0.0445,568.51,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-21",23,22.67,5697.01,,0.012,0.001,2385.644,0.059,0.153,0.0084,40141.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-22",1,0.53,87.98,,0,0.001,40.757,0.059,0.003,0.009,685.714,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-23",9,8.47,2135.56,,0.005,0.001,905.475,0.059,0.101,0.0178,15236.452,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-28",19,18.98,5210.06,,0.011,0.001,2178.696,0.059,0.191,0.0136,36659.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-29",24,24,6326,,0.013,0.001,2628.1,0.059,0.152,0.0069,44225.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-30",24,24,6136,,0.013,0.001,2557.1,0.059,0.149,0.007,43030,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Russell City Energy Company LLC",56467,"CT2",,"2020-12-31",1,0.17,13.09,,0,0.001,9.622,0.059,0.001,0.017,161.976,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-12",3,1.74,79.24,,0,0.001,45.374,0.0593,0.004,0.0093,763.382,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-17",3,1.95,88.23,,0,0.001,50.845,0.0593,0.004,0.009,854.761,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-19",6,5.12,253.8,,0.001,0.001,142.74,0.059,0.011,0.019,2403.824,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-20",5,4.28,211.24,,0.001,0.001,118.44,0.0592,0.009,0.009,1991.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-23",6,5.62,280.28,,0.001,0.001,156.986,0.0593,0.013,0.0102,2640.738,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-24",8,7.37,369.06,,0.001,0.001,206.162,0.0591,0.015,0.0088,3469.511,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-25",3,1.99,90.47,,0,0.001,52.248,0.0593,0.005,0.015,879.195,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-26",4,3.49,162.94,,0,0.001,93.559,0.0593,0.007,0.0103,1573.409,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-27",2,1.24,52.7,,0,0.001,30.752,0.059,0.003,0.012,517.886,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-01",5,4.45,215.09,,0.001,0.001,122.149,0.0592,0.01,0.0102,2054.869,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-02",3,2.74,127.43,,0,0.001,72.444,0.0593,0.007,0.011,1219.183,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-03",8,7.37,364.06,,0.001,0.001,205.173,0.0591,0.016,0.0106,3454.265,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-04",4,2.61,116.27,,0,0.001,67.832,0.059,0.006,0.0098,1141.958,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-05",3,2.49,115.81,,0,0.001,66.494,0.0593,0.006,0.012,1118.38,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-06",2,1.24,52.84,,0,0.001,30.995,0.0595,0.004,0.0135,520.826,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-07",2,1.24,53.32,,0,0.001,31.062,0.0595,0.004,0.0135,522.226,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-08",6,4.99,242.1,,0.001,0.001,137.306,0.0593,0.012,0.0098,2310.413,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-09",5,3.98,180.37,,0.001,0.001,103.991,0.059,0.01,0.0122,1750.419,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-10",6,4.98,230.13,,0.001,0.001,131.432,0.0593,0.011,0.01,2212.043,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-11",7,5.9,288.75,,0.001,0.001,163.519,0.0593,0.013,0.0096,2751.182,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-13",2,0.7,0,,0,0.001,4.41,0.0595,0.004,0.1025,74.18,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-19",5,2.82,90.4,,0,0.001,56.965,0.0592,0.01,0.0344,958.704,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-20",2,1.24,53.94,,0,0.001,31.124,0.059,0.003,0.0125,523.652,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-28",3,2.74,129.17,,0,0.001,73.814,0.0593,0.006,0.0107,1241.408,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-29",3,2.27,105.23,,0,0.001,60.106,0.0593,0.006,0.0123,1010.211,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-30",2,1.25,54.03,,0,0.001,31.339,0.0595,0.003,0.016,526.721,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-03-31",3,1.49,65.51,,0,0.001,37.71,0.059,0.003,0.0113,634.085,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-01",3,2.24,102.7,,0,0.001,58.204,0.059,0.006,0.012,979.65,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-02",2,1.25,53.21,,0,0.001,30.92,0.059,0.004,0.013,520.21,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-03",3,2.49,115.81,,0,0.001,65.648,0.059,0.005,0.0103,1105.407,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-04",4,3.49,166.43,,0,0.001,93.859,0.0593,0.008,0.0105,1579.42,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-05",5,4.24,202.7,,0.001,0.001,115.152,0.0592,0.009,0.01,1936.532,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-06",2,1.24,53.58,,0,0.001,30.832,0.059,0.004,0.0185,518.438,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-07",4,2.73,120.62,,0,0.001,68.996,0.0595,0.007,0.0125,1159.965,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-08",2,1.24,53.94,,0,0.001,30.938,0.059,0.004,0.014,520.924,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-09",7,4.48,208.09,,0.001,0.001,118.209,0.0593,0.012,0.0189,1988.751,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-16",3,2.49,113.45,,0,0.001,64.691,0.0593,0.007,0.0123,1088.684,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-21",1,0.87,39.15,,0,0.001,22.62,0.059,0.004,0.019,380.712,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-22",4,2.61,116.27,,0,0.001,67.309,0.0593,0.005,0.0085,1131.808,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-24",5,3.47,160.73,,0,0.001,92.314,0.0596,0.007,0.0106,1552.397,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-25",5,3.52,163.61,,0,0.001,93.824,0.0592,0.007,0.0106,1580.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-26",2,1.74,77.43,,0,0.001,44.631,0.0595,0.005,0.012,750.984,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-28",3,2.49,114.94,,0,0.001,65.523,0.059,0.006,0.0107,1103.906,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-03",6,5.87,289.15,,0.001,0.001,162.333,0.0593,0.013,0.01,2731.472,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-04",6,5.37,262.69,,0.001,0.001,147.014,0.059,0.011,0.0087,2473.506,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-05",2,1.21,51.37,,0,0.001,29.995,0.059,0.003,0.0105,505.336,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-07",3,1.49,64.12,,0,0.001,37.117,0.059,0.003,0.0237,625.017,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-08",7,6.62,320.66,,0.001,0.001,182.376,0.0591,0.014,0.0096,3070.53,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-09",8,6.99,339.23,,0.001,0.001,192.856,0.0593,0.016,0.0094,3244.109,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-10",6,5.37,263.69,,0.001,0.001,149.525,0.0595,0.011,0.0087,2515.997,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-11",7,5.24,252.64,,0.001,0.001,142.416,0.0593,0.012,0.0164,2396.54,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-14",4,3.49,162.07,,0,0.001,92.5,0.0598,0.007,0.01,1555.125,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-15",4,2.5,113.74,,0,0.001,65.616,0.0595,0.005,0.0203,1103.79,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-16",7,5.24,248.76,,0.001,0.001,142.44,0.0591,0.011,0.0159,2397.432,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-17",4,3.74,175.43,,0.001,0.001,100.244,0.059,0.008,0.0103,1686.892,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-18",4,2.49,114.49,,0,0.001,65.84,0.0593,0.006,0.022,1106.743,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-21",7,6.12,300.8,,0.001,0.001,169.764,0.0593,0.013,0.0159,2856.04,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-22",6,5.12,251.2,,0.001,0.001,141.336,0.0592,0.011,0.0085,2377.268,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-23",5,3.99,190.35,,0.001,0.001,108.08,0.0594,0.009,0.0098,1818.054,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-24",2,1.27,54.75,,0,0.001,31.98,0.0595,0.004,0.0115,538.173,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-25",4,3.52,164.64,,0,0.001,94.35,0.059,0.007,0.009,1588.954,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-26",4,2.99,138.48,,0,0.001,80.107,0.0593,0.007,0.0093,1349.262,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-27",9,7.99,389.23,,0.001,0.001,221.781,0.0594,0.017,0.0091,3730.865,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-28",2,1.24,52.34,,0,0.001,31.03,0.059,0.003,0.0145,521.83,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-29",5,3.74,174.75,,0.001,0.001,100.035,0.059,0.008,0.0108,1684.116,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-30",6,4.49,211.12,,0.001,0.001,122.127,0.059,0.009,0.0163,2054.871,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-05-31",1,0.1,0,,0,0.001,0.6,0.059,0,0.077,10.14,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-06",6,3.4,141.37,,0,0.001,81.829,0.0593,0.015,0.0388,1377.154,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-07",4,3.24,149.46,,0,0.001,84.908,0.0593,0.01,0.0158,1428.542,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-08",3,2.24,101.34,,0,0.001,58.21,0.0593,0.008,0.023,978.599,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-09",4,3.24,147.46,,0,0.001,84.656,0.059,0.009,0.0145,1425.482,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-10",5,4.52,211.93,,0.001,0.001,120.276,0.059,0.013,0.0136,2023.148,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-11",10,7.54,355.06,,0.001,0.001,201.51,0.0591,0.02,0.0324,3392.626,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-12",2,1.24,51.46,,0,0.001,30.256,0.0595,0.006,0.024,508.772,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-13",3,2.24,101.7,,0,0.001,58.142,0.0593,0.008,0.0177,978.054,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-14",4,2.74,125.84,,0,0.001,72.266,0.0595,0.009,0.0433,1215.57,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-16",11,8.37,359.42,,0.001,0.001,209.335,0.0593,0.028,0.0516,3520.502,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-17",3,2.24,100.6,,0,0.001,58.112,0.0593,0.008,0.0187,976.996,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-18",2,1.24,51.6,,0,0.001,30.275,0.059,0.006,0.024,509.815,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-19",6,5.87,283.28,,0.001,0.001,160.785,0.059,0.016,0.0122,2704.682,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-20",9,7.61,360.12,,0.001,0.001,203.356,0.059,0.019,0.0247,3423.828,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-21",3,1.32,45.32,,0,0.001,27.588,0.059,0.008,0.1133,464.486,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-22",4,2.74,125.38,,0,0.001,71.154,0.059,0.009,0.0205,1198.602,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-23",14,11.73,556.46,,0.002,0.001,314.554,0.0592,0.027,0.0224,5293.485,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-24",4,3.5,162.11,,0,0.001,92.694,0.0593,0.011,0.0145,1559.207,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-09",11,9.19,433.75,,0.001,0.001,247.021,0.0591,0.02,0.0296,4156.523,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-17",4,3.9,179.7,,0.001,0.001,103.68,0.0595,0.011,0.0125,1743.46,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-20",10,9.72,461.7,,0.001,0.001,262.126,0.0593,0.022,0.0106,4408.248,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-27",10,8.57,411.53,,0.001,0.001,232.334,0.0593,0.019,0.0157,3907.121,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-29",3,2.24,101.7,,0,0.001,58.242,0.059,0.008,0.0173,980.34,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-30",4,3.49,162.32,,0,0.001,92.277,0.059,0.01,0.0143,1553.099,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-03",11,9.8,466.32,,0.001,0.001,265.176,0.0593,0.021,0.0136,4462.696,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-12",3,2.49,112.7,,0,0.001,64.652,0.059,0.009,0.017,1088.823,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-14",10,8.97,423.75,,0.001,0.001,240.441,0.059,0.02,0.0133,4048.173,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-17",8,7.22,338.02,,0.001,0.001,191.376,0.059,0.016,0.0111,3220.414,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-18",12,11.05,522.25,,0.001,0.001,294.07,0.0595,0.022,0.0108,4946.589,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-21",11,10.29,485.04,,0.001,0.001,272.92,0.0592,0.022,0.0102,4590.662,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-24",6,5.49,254.21,,0.001,0.001,143.857,0.0595,0.014,0.012,2420.854,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-25",3,2.49,111.45,,0,0.001,64.228,0.059,0.007,0.0153,1081.043,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-27",7,5.24,236.31,,0.001,0.001,136.69,0.0591,0.016,0.0224,2300.069,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-28",3,2.74,125.56,,0,0.001,72.344,0.0593,0.009,0.0157,1217.157,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-03",2,1.24,51.47,,0,0.001,30.571,0.059,0.006,0.0285,514.958,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-04",3,2.49,112.7,,0,0.001,65.051,0.0597,0.008,0.0157,1094.061,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-05",10,9.06,427.9,,0.001,0.001,242.712,0.0593,0.02,0.0119,4082.53,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-06",7,5.99,277.22,,0.001,0.001,156.795,0.0593,0.014,0.0257,2637.348,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-08",3,1.65,69.69,,0,0.001,40.525,0.0593,0.005,0.0307,682.017,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-11",3,1.75,77.26,,0,0.001,44.422,0.0593,0.007,0.0543,746.752,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-16",7,5.25,246.63,,0.001,0.001,140.092,0.0594,0.014,0.032,2356.576,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-17",4,2.29,100.91,,0,0.001,58.257,0.0598,0.006,0.0375,979.009,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-18",16,13.47,616.29,,0.002,0.001,352.932,0.0593,0.028,0.0236,5937.499,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-20",3,1.49,63.26,,0,0.001,36.973,0.0597,0.004,0.0337,621.286,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-28",2,1.25,51.96,,0,0.001,30.208,0.059,0.005,0.0205,508.721,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-29",3,1.99,88.36,,0,0.001,50.774,0.0593,0.007,0.0337,853.118,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-03",3,1.75,75.75,,0,0.001,43.675,0.0597,0.005,0.0173,733.958,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-04",3,2.24,98.73,,0,0.001,56.979,0.059,0.007,0.0173,959.109,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-05",4,2.74,125.1,,0,0.001,71.07,0.0595,0.008,0.0408,1196.188,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-06",4,2.99,135.36,,0,0.001,76.521,0.0593,0.008,0.015,1287.914,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-07",3,2.24,100.46,,0,0.001,57.146,0.059,0.007,0.0157,961.822,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-08",1,0.68,29.92,,0,0.001,17.068,0.06,0.002,0.017,286.824,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-09",1,0.87,38.28,,0,0.001,21.75,0.059,0.003,0.016,366.444,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-13",6,4.99,226.12,,0.001,0.001,128.738,0.0592,0.012,0.0145,2167.81,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-14",5,3.47,153.75,,0,0.001,87.489,0.0594,0.011,0.0354,1472.04,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-15",5,4.07,182.53,,0.001,0.001,105.296,0.0594,0.011,0.014,1772.105,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-16",2,1.24,50.22,,0,0.001,29.512,0.059,0.005,0.02,496.496,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-18",2,1.24,51.46,,0,0.001,29.822,0.0595,0.005,0.0195,501.58,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-20",3,1.74,76.12,,0,0.001,43.442,0.059,0.005,0.029,731.656,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-27",3,1.24,44.88,,0,0.001,26.74,0.0593,0.005,0.0577,450.576,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-01",3,2.27,102.34,,0,0.001,59.231,0.0593,0.006,0.0133,996.194,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-02",3,1.99,90.35,,0,0.001,51.464,0.0593,0.007,0.0187,866.529,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-05",6,3.48,153.22,,0,0.001,89.694,0.0593,0.012,0.04,1509.42,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-10",3,1.99,90.35,,0,0.001,51.615,0.059,0.007,0.0197,868.381,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-15",4,2.24,101.88,,0,0.001,57.752,0.059,0.006,0.0463,972.04,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-17",3,1.24,53.88,,0,0.001,30.74,0.059,0.004,0.059,516.896,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-01",5,2.48,105.58,,0,0.001,61.356,0.0592,0.011,0.0576,1032.044,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-02",2,1,41.25,,0,0.001,24.135,0.059,0.006,0.057,406.125,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-19",2,1.24,52.7,,0,0.001,30.814,0.0595,0.005,0.021,518.382,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-20",3,1.24,52.88,,0,0.001,30.8,0.0597,0.006,0.0893,517.812,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","McGrath Generating Station",56471,"CT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-06",1,0.25,0,,0,0.001,1.55,0.059,0,0.013,26.15,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-26",4,1.61,17.37,,0,0.001,17.056,0.0598,0.002,0.014,286.363,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-01-31",3,1.39,24.22,,0,0.0007,18.551,0.059,0.002,0.0133,312.12,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-01",5,3.46,85.68,,0,0.001,57.578,0.059,0.008,0.016,970.328,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-02",4,3.25,64.75,,0,0.001,46.375,0.0595,0.008,0.0185,780.375,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-03",2,1.2,23.8,,0,0.001,17.22,0.0595,0.004,0.0225,289.86,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-04",2,0.7,7.54,,0,0.0005,7.424,0.0595,0.003,0.1015,124.622,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-06",2,1.3,47.7,,0,0.001,28.67,0.059,0.005,0.019,482.98,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-07",1,0.18,0,,0,0.001,1.134,0.059,0.002,0.167,19.062,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-08",4,3.33,136.64,,0,0.001,80.168,0.0593,0.008,0.0123,1350.197,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-09",1,0.1,0,,0,0.001,0.61,0.059,0.001,0.191,10.27,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-15",2,1.17,18.28,,0,0.001,14.704,0.0595,0.004,0.023,247.193,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-16",2,1.23,23.84,,0,0.001,17.216,0.059,0.003,0.0165,290.542,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-23",9,4.73,98.06,,0,0.0009,68.669,0.0594,0.011,0.0147,1156.569,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-27",3,2.3,48.1,,0,0.001,33.84,0.059,0.005,0.0163,569.97,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-28",1,0.02,0,,0,0.001,0.108,0.06,0,0,1.806,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-02-29",5,2.59,47.99,,0,0.001,35.039,0.0596,0.007,0.015,588.821,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-01",11,7.75,167.94,,0.001,0.0009,114.315,0.0593,0.014,0.0127,1923.856,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-03",3,1.87,53.12,,0,0.001,33.731,0.0593,0.005,0.0187,568.123,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-08",4,2.22,50.8,,0,0.001,33.828,0.0595,0.005,0.0163,569.874,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-09",2,1.23,25.84,,0,0.001,17.985,0.0595,0.004,0.0185,302.223,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-11",3,1.24,24.54,,0,0.0007,17.402,0.0593,0.003,0.0093,292.82,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-12",5,2.45,49.44,,0,0.001,35.047,0.0592,0.007,0.0156,590.46,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-13",6,3.52,70.75,,0,0.001,49.602,0.0592,0.008,0.0148,835.879,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-14",7,3.59,69.62,,0,0.0009,50.706,0.0597,0.008,0.0117,852.374,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-15",5,3.27,69,,0,0.001,47.739,0.0592,0.006,0.0114,803.514,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-19",3,1.2,23.08,,0,0.0007,16.718,0.06,0.004,0.0133,280.714,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-28",2,0.63,11.06,,0,0.001,8.533,0.0595,0.001,0.0225,143.703,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-29",5,2.19,40.75,,0,0.0008,29.731,0.0592,0.006,0.0128,500.892,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-03-31",1,0.8,11.2,,0,0.001,9.2,0.06,0.003,0.034,154.16,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-01",5,1.88,32.42,,0,0.001,25.04,0.0594,0.004,0.0482,421.888,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-03",2,1.03,11.26,,0,0.001,10.933,0.0595,0.001,0.0135,184.688,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-04",5,3.26,61.28,,0,0.001,45,0.059,0.006,0.0362,758.402,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-05",12,8.94,256.3,,0.001,0.0009,161.828,0.0594,0.016,0.0152,2721.311,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-06",8,5.68,164.92,,0.001,0.001,103.512,0.0594,0.016,0.0239,1741.51,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-07",18,12.14,339.26,,0.001,0.001,216.458,0.0591,0.022,0.0228,3646.396,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-08",9,5.66,108.16,,0,0.001,78.778,0.0596,0.011,0.0166,1325.564,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-09",10,8.53,322.62,,0.001,0.001,189.917,0.0595,0.016,0.0148,3193.484,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-10",8,6.32,258.88,,0.001,0.001,149.259,0.0594,0.015,0.0123,2509.341,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-11",5,2.5,61.34,,0,0.001,40.443,0.059,0.008,0.0156,680.452,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-12",14,10.88,359.86,,0.001,0.0009,218.542,0.0594,0.023,0.0115,3676.71,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-13",7,3.78,127.3,,0,0.001,77.94,0.0593,0.014,0.0151,1312.316,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-14",2,0.74,6.08,,0,0.001,6.924,0.059,0.001,0.0155,116.818,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-16",4,2.25,87.3,,0,0.0008,51.434,0.0593,0.004,0.0105,866.295,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-18",4,2.34,47.24,,0,0.0008,33.254,0.0595,0.002,0.01,559.676,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-19",5,3.22,76.2,,0,0.0008,50.7,0.0596,0.006,0.012,852.682,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-20",2,0.67,4.55,,0,0.0005,6.057,0.059,0.003,0.0295,101.84,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-26",3,1.27,23.75,,0,0.001,17.541,0.059,0.001,0.0117,295.158,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-28",3,1.25,23.84,,0,0.001,17.445,0.0593,0.001,0.0107,294.071,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-29",3,1.25,23.84,,0,0.001,17.545,0.06,0.004,0.013,294.417,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-06",3,1.25,23.84,,0,0.001,17.491,0.06,0.001,0.0103,293.555,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-16",4,2.25,45.84,,0,0.0008,32.615,0.0593,0.002,0.0093,548.313,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-05-31",3,1.29,41.43,,0,0.0007,25.497,0.0597,0.002,0.01,429.381,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-01",4,2.25,73.84,,0,0.001,45.056,0.0595,0.003,0.0093,757.55,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-02",4,2.34,85.88,,0,0.0008,50.988,0.0593,0.005,0.009,857.688,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-03",11,9.27,414.5,,0.001,0.0009,237.361,0.059,0.015,0.0068,3994.588,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-04",3,1.25,23.61,,0,0.001,17.276,0.059,0.001,0.0087,290.983,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-08",3,1.32,46.7,,0,0.001,28.732,0.0597,0.002,0.0093,482.902,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-09",3,1.25,26.84,,0,0.001,18.947,0.0597,0.003,0.0083,318.187,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-10",12,8.77,315.61,,0.001,0.001,190.518,0.0592,0.015,0.0075,3207.426,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-11",3,1.25,27.61,,0,0.001,19.097,0.0597,0.003,0.0097,320.81,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-14",3,1.27,23.75,,0,0.001,17.693,0.0593,0.001,0.0087,297.775,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-21",4,2.27,46.75,,0,0.001,33.087,0.059,0.002,0.0085,556.961,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-23",3,1.25,23.84,,0,0.001,17.414,0.0597,0.001,0.0093,292.798,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-04",2,0.85,5.59,,0,0.001,7.372,0.059,0.001,0.014,124.456,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-05",2,0.7,4.36,,0,0.001,6.134,0.0595,0.001,0.0135,103.164,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-07",4,2.38,45.81,,0,0.001,33.862,0.0593,0.003,0.0143,569.974,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-10",5,3.35,133.97,,0,0.0008,78.791,0.0592,0.005,0.0066,1326.286,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-12",6,3.52,68.5,,0,0.0008,49.932,0.0595,0.003,0.0087,841.308,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-30",4,2.4,75.24,,0,0.001,46.84,0.06,0.003,0.0275,786.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-13",5,3.34,134.88,,0,0.001,79.048,0.0594,0.004,0.0078,1329.646,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-14",9,8,324.9,,0.001,0.001,190.955,0.059,0.009,0.009,3213.245,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-15",7,3.45,93.28,,0,0.001,60.377,0.0593,0.004,0.0069,1015.602,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-17",9,7.64,315.84,,0.001,0.0009,184.044,0.0593,0.008,0.0059,3095.752,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-18",10,8.32,358.8,,0.001,0.0009,208.314,0.0593,0.046,0.0389,3504.956,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-19",4,2,35.7,,0,0.001,26.87,0.06,0.002,0.0115,450.76,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-20",3,1.27,28,,0,0.001,19.144,0.059,0.002,0.0073,322.836,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-21",2,0.65,3.15,,0,0.001,5.26,0.0595,0.002,0.0225,88.093,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-22",2,0.62,3.21,,0,0.001,5.101,0.0595,0.001,0.0255,85.921,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-23",6,3.73,129.17,,0,0.001,78.472,0.0592,0.006,0.02,1320.787,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-24",4,2.32,80.1,,0,0.001,48.448,0.06,0.004,0.0083,813.566,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-25",4,2.27,90.5,,0,0.001,53.314,0.0595,0.005,0.0075,896.308,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-26",7,3.39,99.91,,0,0.0009,63.79,0.0594,0.005,0.009,1074.251,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-27",5,3.66,145.03,,0,0.001,85.034,0.0594,0.005,0.0082,1431.15,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-28",9,7.43,315.76,,0.001,0.001,183.864,0.0591,0.011,0.0128,3094.026,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-30",3,1.24,44.98,,0,0.001,27.286,0.0593,0.001,0.0093,458.822,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-08-31",3,1.32,45.7,,0,0.001,27.826,0.0593,0.004,0.0097,468.722,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-01",4,2.25,92.3,,0,0.0008,54.318,0.0593,0.005,0.0085,913.966,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-03",6,4.24,178.42,,0.001,0.001,103.266,0.0593,0.007,0.0073,1737.766,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-04",9,7.32,316.7,,0.001,0.001,183.48,0.0596,0.011,0.0066,3085.178,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-05",4,3.09,92.21,,0,0.001,58.632,0.0598,0.005,0.0103,985.682,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-06",3,1.77,61.13,,0,0.001,37.283,0.0593,0.003,0.019,627,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-07",4,2.25,90.3,,0,0.0008,52.976,0.0593,0.004,0.007,891.178,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-08",6,3.6,133.47,,0,0.001,80.215,0.0592,0.007,0.0082,1350.289,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-10",4,2.25,93.3,,0,0.0008,54.966,0.059,0.005,0.0095,925.238,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-11",3,1.35,44.97,,0,0.001,27.777,0.0593,0.003,0.0133,467.101,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-13",5,3.25,140.3,,0,0.001,80.844,0.059,0.004,0.0076,1360.878,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-14",4,2.25,92.53,,0,0.001,54.105,0.0593,0.005,0.0085,911.935,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-15",13,9.5,390.14,,0.001,0.001,228.958,0.0592,0.017,0.0082,3853.571,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-16",6,4.29,189.43,,0.001,0.001,110.419,0.059,0.008,0.0083,1857.154,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-17",6,4.25,186.3,,0.001,0.001,109.156,0.0592,0.01,0.0117,1836.244,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-18",6,3.89,136.86,,0,0.001,84.341,0.0592,0.013,0.0235,1418.184,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-19",5,3.35,132.97,,0,0.0008,78.289,0.0592,0.016,0.0336,1317.111,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-20",6,4.34,184.88,,0.001,0.0008,107.024,0.0593,0.008,0.0077,1800.118,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-21",3,1.25,46.3,,0,0.001,27.765,0.0593,0.004,0.0097,467.927,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-22",3,1.35,45.97,,0,0.001,28.204,0.0597,0.004,0.0093,475.111,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-23",4,2.35,90.97,,0,0.001,53.619,0.059,0.005,0.0083,903.252,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-24",3,1.29,45.7,,0,0.001,27.704,0.059,0.003,0.0087,466.965,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-25",4,2.3,91.24,,0,0.001,53.434,0.0595,0.005,0.009,899.292,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-26",4,2.35,89.97,,0,0.001,52.846,0.0593,0.011,0.0215,889.718,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-27",4,2.35,84.97,,0,0.001,50.415,0.0593,0.011,0.0435,848.122,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-28",4,2.35,87.97,,0,0.0008,52.223,0.0593,0.011,0.0425,879.768,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-29",7,4.74,182.88,,0.001,0.0009,108.146,0.0593,0.011,0.0214,1820.402,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-09-30",7,4.65,174.25,,0.001,0.001,103.59,0.0591,0.007,0.019,1744.025,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-01",7,3.57,133.7,,0,0.001,79.33,0.0593,0.006,0.0076,1334.299,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-02",5,3.24,137.2,,0,0.0008,80.078,0.0592,0.005,0.0064,1347.612,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-03",6,4.25,186.3,,0.001,0.001,107.094,0.0595,0.009,0.0092,1801.016,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-04",6,4.25,185.3,,0.001,0.001,106.748,0.0593,0.008,0.0097,1796.268,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-05",10,7.52,303.19,,0.001,0.001,179.155,0.0594,0.011,0.0075,3015.724,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-06",5,3.76,162,,0,0.001,93.984,0.0594,0.007,0.0104,1580.58,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-07",4,2.34,91.88,,0,0.001,54.576,0.059,0.005,0.0073,918.49,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-08",3,1.29,44.7,,0,0.001,26.888,0.0593,0.004,0.0093,452.519,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-09",3,1.29,46.43,,0,0.001,28.196,0.0593,0.003,0.0133,474.587,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-11",6,4.25,184.3,,0.001,0.001,107.363,0.059,0.008,0.0097,1806.98,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-12",4,2.25,92.3,,0,0.001,54.407,0.059,0.005,0.0078,915.874,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-13",6,3.77,150.93,,0,0.0008,89.974,0.0592,0.008,0.0115,1515.008,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-14",6,4.25,187.3,,0.001,0.0008,108.27,0.0592,0.007,0.0065,1822.643,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-15",10,7.63,207.55,,0.001,0.0009,136.256,0.0592,0.014,0.0132,2292.563,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-16",5,3.3,130.96,,0,0.0008,77.198,0.0592,0.005,0.009,1299.074,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-17",5,3.34,128.88,,0,0.001,76.012,0.0596,0.006,0.0072,1278.764,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-18",4,2.25,90.3,,0,0.0008,53.234,0.0593,0.005,0.0075,895.849,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-19",4,2.34,86.56,,0,0.001,51.354,0.059,0.005,0.0083,864.782,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-20",4,2.27,82.25,,0,0.0008,49.195,0.059,0.004,0.0075,828.282,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-22",4,2.32,92.7,,0,0.001,54.67,0.0593,0.006,0.009,920.128,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-23",3,1.3,28.96,,0,0.001,20.062,0.0593,0.003,0.0103,337.028,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-24",6,3.26,136.2,,0,0.0008,79.766,0.0593,0.012,0.029,1342.29,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-25",13,8.17,308.07,,0.001,0.0009,182.568,0.0595,0.028,0.0301,3070.386,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-26",5,3.25,134.3,,0,0.001,77.923,0.0592,0.007,0.009,1311.814,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-27",7,3.58,137.54,,0,0.001,81.816,0.0597,0.009,0.0089,1375.654,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-28",8,2.9,85.53,,0,0.001,54.208,0.0595,0.008,0.0158,911.963,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-29",6,2.66,86.58,,0,0.001,53.756,0.0595,0.012,0.0353,904.72,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-30",3,1.25,41.07,,0,0.001,25.235,0.0593,0.006,0.0493,424.036,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-10-31",3,1.27,27.25,,0,0.001,19.002,0.059,0.005,0.0503,320.28,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-01",8,6.24,260.98,,0.001,0.0009,151.528,0.059,0.023,0.0256,2551.274,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-02",3,1.29,42.43,,0,0.0007,26.049,0.059,0.003,0.008,438.287,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-03",4,2.27,73.75,,0,0.0008,44.849,0.0593,0.004,0.0075,755.596,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-04",3,1.25,44.07,,0,0.0007,26.797,0.059,0.003,0.0073,450.692,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-05",6,4.29,178.16,,0.001,0.001,103.119,0.059,0.006,0.006,1734.312,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-08",3,1.34,45.88,,0,0.001,27.968,0.0597,0.004,0.0097,470.13,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-10",3,1.34,37.88,,0,0.001,23.946,0.0597,0.003,0.0097,402.98,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-11",7,3.57,130.77,,0,0.0007,78.259,0.0594,0.015,0.043,1317.045,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-12",6,2.68,87.76,,0,0.0007,54.034,0.0592,0.011,0.0467,910.136,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-13",3,1.32,36.7,,0,0.0007,23.668,0.0597,0.005,0.0413,398.088,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-14",4,2.34,89.88,,0,0.001,53.772,0.0593,0.005,0.0075,906.116,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-15",3,1.35,42.97,,0,0.0007,27.12,0.0593,0.003,0.008,456.777,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-16",3,1.35,38.97,,0,0.0007,25.07,0.059,0.002,0.0067,422.646,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-19",2,0.4,9.88,,0,0.0005,6.542,0.0595,0.002,0.017,109.872,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-22",2,1.56,0,,0,0.001,9.609,0.06,0.012,0.1555,160.767,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-24",6,2.5,92.14,,0,0.0008,55.444,0.0592,0.007,0.0097,932.865,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-25",3,1.34,36.88,,0,0.0007,23.636,0.0593,0.003,0.0083,397.608,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-26",10,5.61,192.03,,0.001,0.0009,116.63,0.0593,0.024,0.0326,1963.377,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-28",3,1.35,43.97,,0,0.0007,27.154,0.0593,0.005,0.0513,456.618,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-03",3,1.32,44.7,,0,0.001,27.628,0.0593,0.005,0.0513,464.828,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-04",12,9.59,422.81,,0.001,0.001,244.699,0.0591,0.044,0.0298,4117.999,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-05",6,2.52,69.34,,0,0.0008,44.415,0.0593,0.012,0.0548,746.898,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-06",6,2.5,91.37,,0,0.001,55.25,0.0592,0.04,0.1352,929.535,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-07",4,2.35,88.97,,0,0.0008,52.331,0.0598,0.066,0.2015,880.533,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-08",3,1.27,40.5,,0,0.001,24.914,0.0597,0.011,0.1823,419.256,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-09",3,1.17,15.45,,0,0.001,13.398,0.059,0.019,0.1503,225.611,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-10",3,1.34,39.88,,0,0.001,25.116,0.059,0.012,0.1823,422.472,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-11",3,1.32,46.7,,0,0.001,28.326,0.0593,0.036,0.219,477.262,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-12",12,8.56,303.48,,0.001,0.0009,182.866,0.0593,0.122,0.1233,3076.818,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-13",3,1.2,22.9,,0,0.001,16.342,0.0593,0.003,0.0113,275.124,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-15",11,6.09,163.36,,0.001,0.0008,105.643,0.0593,0.011,0.0097,1778.397,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-16",12,6.78,178.26,,0.001,0.0009,115.468,0.0592,0.022,0.0254,1944.107,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-17",3,1.22,39,,0,0.001,23.792,0.059,0.01,0.1823,400.352,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-18",7,3.52,116.34,,0,0.0009,70.925,0.0593,0.076,0.1944,1193.771,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-19",3,1.25,23.38,,0,0.001,17.07,0.0593,0.009,0.185,287.173,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-20",12,8.64,365.8,,0.001,0.001,211.296,0.0591,0.041,0.0473,3557.33,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-21",6,2.5,92.37,,0,0.001,55.779,0.0592,0.006,0.0078,938.897,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-22",3,1.32,44.7,,0,0.001,27.418,0.0593,0.004,0.009,461.978,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-23",9,4.84,166.32,,0.001,0.001,101.402,0.0593,0.045,0.0561,1708.117,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-24",8,4.56,161.43,,0,0.001,97.004,0.0594,0.083,0.1745,1631.021,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-26",15,10.19,399.97,,0.001,0.001,234.477,0.0592,0.048,0.0421,3944.39,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-27",4,2.25,88.3,,0,0.001,51.802,0.0595,0.005,0.0093,871.376,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-30",5,2.27,84.3,,0,0.0008,49.669,0.0594,0.007,0.0104,835.071,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Grapeland Generating Station",56472,"CT1",,"2020-12-31",7,2.97,84.04,,0,0.0007,53.491,0.0591,0.018,0.1023,900.916,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-17",2,1.39,58.56,,0,0.001,34.631,0.059,0.008,0.0295,582.298,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-28",3,1.4,57.2,,0,0.001,34.272,0.0597,0.007,0.0737,576.16,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-29",4,2.89,131.49,,0,0.001,76.619,0.0595,0.009,0.02,1288.808,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-30",3,1.37,55.8,,0,0.001,33.326,0.0597,0.008,0.0883,560.112,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-01-31",3,1.5,59.38,,0,0.001,35.683,0.059,0.006,0.0517,600.458,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-02",3,1.49,61.89,,0,0.001,36.412,0.0593,0.006,0.046,612.082,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-15",2,1.37,56.92,,0,0.001,33.578,0.059,0.006,0.023,565.072,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-16",6,4.83,222.6,,0.001,0.001,128.254,0.059,0.013,0.0157,2159.196,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-17",1,0.38,7.98,,0,0.001,5.548,0.06,0.021,0.461,93.062,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-18",3,1.4,55.86,,0,0.001,33.01,0.059,0.006,0.0493,556.194,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-19",6,5.12,241.8,,0.001,0.001,139.636,0.059,0.012,0.0303,2351.624,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-20",5,4.28,203.96,,0.001,0.001,118.112,0.0592,0.01,0.014,1987.78,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-21",1,0.27,0,,0,0.001,1.647,0.059,0.005,0.331,27.891,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-25",3,1.99,84.5,,0,0.001,49.609,0.059,0.007,0.0197,834.629,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-26",4,2.99,131.1,,0,0.001,76.815,0.059,0.009,0.0518,1294.146,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-27",2,1.37,56.17,,0,0.001,33.565,0.0595,0.007,0.0255,564.642,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-01",5,3.74,174.34,,0.001,0.001,99.764,0.059,0.011,0.037,1679.754,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-02",2,1.74,73.95,,0,0.001,42.891,0.0595,0.007,0.02,721.578,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-03",5,4.24,194.1,,0.001,0.001,111.838,0.0594,0.012,0.0168,1880.749,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-04",3,2.49,109.21,,0,0.001,64.39,0.059,0.008,0.0157,1083.647,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-05",3,2.49,107.09,,0,0.001,62.583,0.0593,0.008,0.0167,1052.24,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-06",2,1.37,56.91,,0,0.001,33.4,0.0595,0.007,0.0285,562.368,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-08",1,0.1,0,,0,0.001,0.6,0.059,0.001,0.229,10.17,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-14",9,6.74,306.19,,0.001,0.001,181.071,0.0591,0.023,0.0399,3046.621,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-15",10,7.8,348.69,,0.001,0.001,204.695,0.0593,0.026,0.0204,3444.165,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-16",6,4.51,201.06,,0.001,0.001,118.558,0.0592,0.017,0.0202,1996.241,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-17",2,1.45,62.35,,0,0.001,37.1,0.059,0.007,0.023,624.443,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-18",2,1.47,62.28,,0,0.001,36.846,0.059,0.007,0.022,620.796,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-19",5,3.46,153.52,,0,0.001,89.934,0.059,0.013,0.018,1513.524,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-28",5,3.99,182.11,,0.001,0.001,105.616,0.059,0.011,0.015,1776.778,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-29",3,2.49,111.45,,0,0.001,64.502,0.059,0.008,0.0167,1085.71,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-30",5,2.98,127.08,,0,0.001,74.932,0.059,0.011,0.0324,1261.946,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-01",5,3.12,129.48,,0,0.001,78.254,0.0594,0.014,0.056,1316.428,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-02",5,3.59,153.3,,0,0.001,90.688,0.0594,0.014,0.0192,1525.491,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-03",5,3.89,168.63,,0.001,0.001,99.24,0.059,0.015,0.0194,1669.122,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-04",5,4.24,193.84,,0.001,0.001,112.894,0.0594,0.012,0.0142,1899.866,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-05",12,9.79,448.2,,0.001,0.001,258.513,0.0593,0.025,0.0169,4350.216,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-06",5,2.63,110.5,,0,0.001,65.044,0.0594,0.011,0.0562,1094.571,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-07",3,1.42,60.7,,0,0.001,35.486,0.0593,0.007,0.077,597.304,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-08",4,2.72,123.97,,0,0.001,71.869,0.0593,0.009,0.022,1209.025,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-09",6,4.22,198.78,,0.001,0.001,114.084,0.0592,0.011,0.0487,1920.502,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-12",2,1.44,60.48,,0,0.001,35.588,0.059,0.007,0.0245,599.382,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-16",5,4.24,192.84,,0.001,0.001,111.346,0.0592,0.012,0.0146,1873.698,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-24",3,1.99,77.53,,0,0.001,46.903,0.059,0.006,0.0363,788.965,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-25",4,2.77,121.05,,0,0.001,71.377,0.0593,0.008,0.028,1201.667,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-26",2,1.74,71.34,,0,0.001,42.63,0.059,0.006,0.0175,717.315,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-27",3,1.99,83.5,,0,0.001,49.396,0.0593,0.007,0.0207,830.445,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-28",7,5.74,256.76,,0.001,0.001,150.354,0.059,0.014,0.023,2530.848,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-01",5,3.99,173.62,,0.001,0.001,101.064,0.059,0.01,0.0244,1701.367,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-03",6,4.99,226.49,,0.001,0.001,133.723,0.0592,0.013,0.0255,2249.769,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-04",6,5.19,234.02,,0.001,0.001,137.036,0.0592,0.013,0.0137,2305.556,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-05",4,2.02,79.24,,0,0.001,47.889,0.0593,0.01,0.0555,806.269,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-07",3,1.52,61.68,,0,0.001,37.08,0.0593,0.006,0.0573,623.528,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-08",4,2.74,119.27,,0,0.001,69.906,0.0593,0.008,0.0188,1177.253,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-09",6,4.49,201.75,,0.001,0.001,117.565,0.0593,0.012,0.0323,1977.325,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-11",7,5.24,241,,0.001,0.001,137.76,0.059,0.013,0.0407,2319.576,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-14",4,3.25,145.62,,0,0.001,84.585,0.059,0.009,0.0148,1423.243,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-15",4,2.5,108.98,,0,0.001,64.084,0.059,0.007,0.0413,1079.02,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-16",7,5.24,236.64,,0.001,0.001,138.14,0.0591,0.013,0.0356,2323.896,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-17",3,2.49,108.59,,0,0.001,63.667,0.0597,0.008,0.0153,1070.863,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-18",4,2.49,108.87,,0,0.001,63.863,0.0593,0.008,0.044,1074.702,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-21",7,5.24,235.76,,0.001,0.001,139.024,0.059,0.013,0.0374,2338.412,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-23",6,5.49,248.34,,0.001,0.001,146.926,0.059,0.014,0.0125,2473.397,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-24",2,1.37,55.54,,0,0.001,33.25,0.059,0.007,0.026,560.331,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-25",4,3.5,153.76,,0,0.001,90.43,0.0593,0.01,0.0138,1520.592,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-26",6,4.99,224.34,,0.001,0.001,131.199,0.0593,0.012,0.0302,2207.193,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-27",9,7.99,362.63,,0.001,0.001,212.028,0.0593,0.019,0.019,3566.486,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-28",3,1.5,60.88,,0,0.001,36.909,0.0593,0.005,0.038,620.361,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-29",2,1.37,56.17,,0,0.001,33.79,0.0595,0.006,0.021,568.585,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-30",6,4.24,194.12,,0.001,0.001,113.808,0.059,0.011,0.0433,1915.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-05-31",3,2.49,108.34,,0,0.001,64.103,0.0593,0.008,0.0157,1078.535,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-01",3,2.24,96.86,,0,0.001,56.727,0.059,0.007,0.0197,954.823,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-02",13,9.74,437.1,,0.001,0.001,256.156,0.0595,0.024,0.0348,4308.526,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-03",4,3.24,142.6,,0,0.001,83.76,0.0593,0.009,0.0148,1410.112,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-04",6,4.99,224.75,,0.001,0.001,131.37,0.0592,0.013,0.0142,2209.782,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-06",5,3.24,143.88,,0,0.001,85.04,0.0594,0.009,0.05,1430.46,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-08",3,2,86.52,,0,0.001,51.192,0.059,0.008,0.065,861.424,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-09",13,10.09,460.63,,0.001,0.001,270.447,0.0593,0.026,0.0297,4550.116,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-10",7,6.87,319.54,,0.001,0.001,187.75,0.0593,0.018,0.0117,3159.905,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-11",10,7.86,356.47,,0.001,0.001,209.526,0.059,0.019,0.019,3527.138,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-12",2,1.24,50.22,,0,0.001,30.132,0.059,0.006,0.0245,507.346,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-13",3,2.24,97.22,,0,0.001,57.818,0.0593,0.007,0.0167,972.312,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-14",4,2.99,129.5,,0,0.001,76.87,0.0593,0.009,0.0183,1292.975,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-16",3,1.99,81.62,,0,0.001,49.013,0.059,0.007,0.0383,824.424,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-17",3,1.99,84.5,,0,0.001,50.388,0.0593,0.007,0.039,847.614,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-18",3,1.99,85.37,,0,0.001,49.921,0.059,0.007,0.0183,839.636,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-19",6,4.99,222.62,,0.001,0.001,129.975,0.0593,0.013,0.0217,2187.883,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-20",4,2.74,118.86,,0,0.001,69.908,0.059,0.008,0.0443,1177.724,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-21",4,2.99,129.5,,0,0.001,76.408,0.059,0.009,0.0175,1286.736,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-22",3,2.49,106.47,,0,0.001,63.12,0.059,0.007,0.0153,1061.608,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-23",4,3.49,151.85,,0,0.001,89.783,0.0595,0.01,0.0145,1510.829,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-24",4,3.74,163.34,,0,0.001,96.478,0.059,0.011,0.014,1624.144,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-06",7,5.24,236.88,,0.001,0.001,138.572,0.0593,0.013,0.0381,2330.384,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-07",3,2.35,100.48,,0,0.001,59.416,0.0593,0.007,0.019,999.566,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-11",8,6.49,294.4,,0.001,0.001,173.073,0.059,0.016,0.0214,2911.719,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-16",2,1.04,40.17,,0,0.001,24.249,0.0595,0.007,0.0475,407.627,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-17",4,2.4,100.21,,0,0.001,59.703,0.0593,0.008,0.0173,1003.882,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-29",3,1.49,57.66,,0,0.001,34.881,0.0593,0.005,0.0373,586.466,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-30",3,1.99,74.39,,0,0.001,45.136,0.059,0.007,0.0323,760.688,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-03",10,8.82,396.08,,0.001,0.001,232.582,0.0593,0.02,0.0172,3911.376,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-12",6,5.74,258.21,,0.001,0.001,152.113,0.0592,0.015,0.0123,2560.261,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-14",11,9.24,409.88,,0.001,0.001,241.272,0.0591,0.021,0.0264,4059.816,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-15",5,3.24,135.12,,0,0.001,80.12,0.0592,0.011,0.0478,1348.036,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-17",8,6.7,293.71,,0.001,0.001,172.835,0.0593,0.017,0.0358,2908.375,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-18",9,7.49,326.14,,0.001,0.001,193.319,0.0594,0.017,0.0224,3253.269,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-19",4,2.99,127.47,,0,0.001,75.652,0.0593,0.01,0.0363,1273.105,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-20",5,3.24,138,,0,0.001,81.548,0.059,0.008,0.0426,1373.324,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-24",4,3.24,139.25,,0,0.001,82.072,0.0593,0.009,0.0155,1381.247,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-28",4,2.39,100.45,,0,0.001,59.848,0.0595,0.007,0.036,1006.687,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-04",3,2.49,104.85,,0,0.001,61.289,0.059,0.008,0.0157,1032.699,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-05",10,9.06,400.75,,0.001,0.001,233.087,0.0591,0.021,0.0133,3925.675,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-06",7,5.99,263.35,,0.001,0.001,154.079,0.059,0.014,0.0267,2593.681,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-08",3,1.65,67.75,,0,0.001,40.02,0.0593,0.005,0.0333,672.757,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-10",6,3.13,131.31,,0,0.001,77.147,0.059,0.011,0.0575,1299.565,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-14",2,1.49,60.47,,0,0.001,35.773,0.059,0.005,0.0185,602.205,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-15",4,2.24,95.24,,0,0.001,55.88,0.0595,0.007,0.057,940.712,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-17",3,1.99,83.47,,0,0.001,49.464,0.0593,0.007,0.0597,832.357,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-18",13,9.48,407,,0.001,0.001,239.244,0.0593,0.023,0.0379,4025.204,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-27",2,1.25,50,,0,0.001,29.624,0.059,0.007,0.029,498.79,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-28",3,2.49,104.85,,0,0.001,61.513,0.059,0.011,0.023,1035.711,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-29",5,3.34,136.11,,0,0.001,80.765,0.0596,0.013,0.0366,1358.056,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-09-30",3,2.49,105.47,,0,0.001,61.661,0.059,0.011,0.023,1037.494,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-01",5,3.65,159.75,,0,0.001,92.096,0.0592,0.01,0.0272,1549.95,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-02",2,1.24,48.36,,0,0.001,28.954,0.059,0.007,0.029,487.754,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-03",3,1.75,72.62,,0,0.001,42.43,0.0593,0.006,0.0357,714.602,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-04",4,3.49,152.47,,0,0.001,88.373,0.059,0.01,0.0145,1488.281,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-05",4,3.49,152.72,,0,0.001,88.96,0.0595,0.01,0.0143,1496.45,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-06",3,2.49,106.47,,0,0.001,62.459,0.0593,0.007,0.0153,1050.421,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-07",2,1.24,48.99,,0,0.001,29.033,0.059,0.005,0.024,488.351,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-12",7,5.74,256.27,,0.001,0.001,149.869,0.0593,0.015,0.0159,2521.065,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-13",6,3.97,164.52,,0,0.001,97.875,0.0593,0.013,0.0313,1646.434,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-14",6,4.22,176.12,,0.001,0.001,104.338,0.0593,0.013,0.0287,1754.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-15",4,3.24,140.98,,0,0.001,82.812,0.0593,0.009,0.015,1394.078,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-16",2,1.24,47.88,,0,0.001,29.085,0.0595,0.005,0.0215,488.911,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-18",3,2.24,94.98,,0,0.001,56.15,0.0593,0.007,0.0167,944.004,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-19",2,1.49,60.47,,0,0.001,35.81,0.059,0.005,0.018,603.084,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-20",2,1.24,48.98,,0,0.001,29.14,0.0595,0.005,0.02,489.862,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-21",3,2.24,94.98,,0,0.001,55.726,0.0593,0.007,0.0167,938.52,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-29",3,1.24,43.52,,0,0.001,26.62,0.0593,0.005,0.0893,448.008,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-03",2,0.99,39.36,,0,0.001,23.199,0.0595,0.005,0.051,390.912,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-13",7,5.82,268.93,,0.001,0.001,153.627,0.0591,0.014,0.0369,2586.035,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-19",2,1.12,47.48,,0,0.001,27.772,0.0595,0.006,0.025,466.837,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mira Loma Generating Station",56473,"CT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-20",3,1.82,74.04,,0,0.001,44.08,0.059,0.005,0.0197,741.741,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-25",12,9.81,467.77,,0.001,0.001,269.794,0.0591,0.01,0.0093,4542.22,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-27",2,1.5,63.88,,0,0.001,37.226,0.059,0.002,0.0075,626.884,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-28",5,3.99,185.73,,0.001,0.001,106.204,0.0594,0.002,0.003,1787.408,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-29",2,1.37,57.06,,0,0.001,33.762,0.0595,0.001,0.0045,568.589,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-30",8,6.99,335.36,,0.001,0.001,192.758,0.0593,0.004,0.0031,3243.256,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-03",2,1.24,52.84,,0,0.001,30.784,0.059,0.001,0.0045,517.424,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-04",2,1.39,61.34,,0,0.001,35.76,0.059,0.002,0.0075,602.17,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-12",3,1.99,88.98,,0,0.001,51.477,0.059,0.001,0.0027,865.987,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-17",4,2.45,110.68,,0,0.001,64.066,0.0593,0.001,0.0073,1078.128,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-19",6,5.12,247.92,,0.001,0.001,141.036,0.0592,0.003,0.009,2372.46,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-20",5,4.27,208.91,,0.001,0.001,118.843,0.059,0.002,0.0022,2001.105,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-22",3,1.56,59.11,,0,0.001,35.552,0.059,0.001,0.002,598.669,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-26",4,3.49,158.83,,0,0.001,91.016,0.0593,0.002,0.0025,1530.593,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-27",7,4.12,172.5,,0.001,0.0009,102.074,0.0593,0.006,0.0077,1716.589,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-28",7,5.31,241.42,,0.001,0.001,138.333,0.0591,0.011,0.0109,2327.305,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-01",7,6.45,307.64,,0.001,0.001,174.434,0.0593,0.009,0.0063,2934.011,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-03",8,7.37,354.69,,0.001,0.001,200.251,0.0593,0.013,0.0095,3368.539,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-04",5,3.11,136.56,,0,0.001,78.993,0.0594,0.007,0.0136,1328.146,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-05",4,2.99,133.37,,0,0.001,76.035,0.0593,0.004,0.0063,1279.41,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-06",12,10.57,492.78,,0.001,0.001,280.247,0.0592,0.015,0.0128,4717.434,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-07",2,1.37,58.91,,0,0.001,34.899,0.0595,0.003,0.0125,587.333,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-08",7,5.49,260.14,,0.001,0.001,148.633,0.0594,0.01,0.0076,2500.134,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-09",6,4.99,223.21,,0.001,0.001,129.355,0.0592,0.011,0.01,2178.32,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-10",3,2.24,100.46,,0,0.001,58.094,0.0593,0.006,0.014,976.47,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-11",2,0.85,32.05,,0,0.001,19.309,0.059,0.005,0.026,325.134,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-12",7,6.06,278.52,,0.001,0.001,159.824,0.0591,0.01,0.0077,2689.351,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-13",11,10.64,507.62,,0.001,0.001,286.073,0.0593,0.02,0.0085,4812.163,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-15",5,4.49,211.94,,0.001,0.001,120.674,0.059,0.01,0.011,2031.279,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-16",10,8.24,379.4,,0.001,0.001,218.988,0.0591,0.02,0.0163,3686.403,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-17",2,1.45,63.8,,0,0.001,37.058,0.059,0.005,0.017,624.062,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-18",2,1.45,63.51,,0,0.001,37.236,0.059,0.005,0.0155,626.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-19",5,3.48,154.4,,0,0.001,89.218,0.0592,0.011,0.015,1501.456,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-21",5,2.81,120.5,,0,0.001,69.524,0.059,0.006,0.0122,1170.73,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-27",2,1.5,62.15,,0,0.001,35.879,0.059,0.004,0.0125,603.497,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-28",5,4.24,195.47,,0.001,0.001,111.014,0.0592,0.006,0.0094,1868.663,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-29",3,2.25,99.9,,0,0.001,57.562,0.0593,0.005,0.0153,969.421,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-30",2,1.45,60.9,,0,0.001,35.256,0.0595,0.003,0.012,593.347,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-03-31",2,1.39,57.69,,0,0.001,33.397,0.0595,0.004,0.0125,561.51,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-01",3,2.24,98.22,,0,0.001,56.66,0.0593,0.004,0.0097,953.612,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-02",2,1.49,62.21,,0,0.001,36.407,0.059,0.003,0.0095,612.834,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-03",5,3.89,171.03,,0,0.001,97.787,0.0592,0.009,0.012,1646.55,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-04",5,3.99,182.74,,0.001,0.001,104.048,0.059,0.007,0.0114,1751.39,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-05",9,6.38,289.41,,0.001,0.0009,164.257,0.0593,0.006,0.0138,2764.094,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-06",5,3.3,149.76,,0,0.001,85.414,0.059,0.005,0.0332,1436.902,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-07",5,2.91,126.05,,0,0.001,71.731,0.0592,0.007,0.0364,1206.014,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-08",3,2.24,100.6,,0,0.001,57.414,0.059,0.005,0.01,966.674,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-16",4,3.49,155.96,,0,0.001,87.463,0.0593,0.009,0.0133,1470.989,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-17",3,1.49,61.87,,0,0.001,35.944,0.059,0.003,0.011,605.337,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-21",3,1.74,73.5,,0,0.001,42.294,0.059,0.003,0.0077,711.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-22",3,1.87,72.32,,0,0.001,43.22,0.059,0.004,0.0123,728.58,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-24",9,5.99,273.55,,0.001,0.001,159.246,0.0593,0.008,0.0141,2678.868,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-25",5,3.5,160.77,,0,0.001,93.717,0.0592,0.003,0.0066,1577.717,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-26",3,2.49,113.32,,0,0.001,66.059,0.059,0.007,0.012,1112.166,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-27",3,1.99,88.11,,0,0.001,51.949,0.059,0.004,0.011,874.735,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-28",3,2.24,100.46,,0,0.001,58.752,0.059,0.005,0.0117,988.042,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-01",9,5.96,262.12,,0.001,0.001,152.688,0.0592,0.01,0.0109,2569.496,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-02",6,4.54,213.46,,0.001,0.001,122.712,0.0592,0.005,0.0077,2064.629,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-03",6,5.87,282.28,,0.001,0.001,161.672,0.059,0.01,0.0077,2721.092,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-04",12,10.36,490.18,,0.001,0.001,282.312,0.059,0.014,0.0063,4749.825,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-08",4,2.99,136.11,,0,0.001,79.202,0.0593,0.004,0.0085,1332.35,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-09",6,4.99,235.36,,0.001,0.001,134.766,0.0592,0.005,0.005,2266.247,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-11",7,5.24,250.88,,0.001,0.001,144.764,0.0591,0.005,0.016,2436.844,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-12",6,4.74,223.24,,0.001,0.001,129.048,0.0592,0.009,0.0152,2170.962,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-13",7,6.37,306.06,,0.001,0.001,176.536,0.0594,0.006,0.006,2968.647,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-14",6,4.62,210.91,,0.001,0.001,121.905,0.0592,0.006,0.0205,2051.147,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-15",4,2.5,111.36,,0,0.001,64.85,0.0593,0.003,0.024,1090.328,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-16",7,5.49,251.75,,0.001,0.001,145.53,0.0593,0.005,0.01,2448.505,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-17",3,1.99,86.37,,0,0.001,50.569,0.059,0.003,0.0067,851.271,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-18",4,2.74,123.01,,0,0.001,71.054,0.059,0.005,0.0105,1195.376,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-20",2,1.35,57.48,,0,0.001,33.648,0.0595,0.002,0.0075,565.908,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-21",7,6.12,287.8,,0.001,0.001,164.476,0.0591,0.01,0.0094,2769.376,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-22",6,5.12,241.08,,0.001,0.001,137.636,0.0592,0.007,0.0067,2317.112,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-23",3,2.49,110.83,,0,0.001,64.863,0.0593,0.005,0.0093,1090.869,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-24",3,1.75,75.75,,0,0.001,44.351,0.0593,0.002,0.008,746.168,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-25",4,3.35,150.76,,0,0.001,87.827,0.0593,0.003,0.0045,1477.832,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-26",4,3.74,169.08,,0,0.001,98.374,0.0593,0.004,0.0045,1655.889,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-27",9,7.99,372.61,,0.001,0.001,215.71,0.0593,0.007,0.0046,3628.517,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-28",3,1.5,63.25,,0,0.001,37.57,0.0593,0.002,0.011,632.046,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-29",5,3.99,183.11,,0.001,0.001,106.315,0.0592,0.004,0.0068,1789.723,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-30",8,6.24,291.12,,0.001,0.001,167.884,0.0593,0.008,0.0186,2824.06,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-05-31",6,3.99,174.57,,0.001,0.001,102.628,0.0592,0.005,0.0092,1726.997,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-01",3,2.24,99.1,,0,0.001,57.873,0.06,0.003,0.0083,972.376,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-02",3,2.24,98.22,,0,0.001,57.308,0.059,0.004,0.009,965.038,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-03",2,1.44,63.34,,0,0.001,36.814,0.059,0.001,0.0035,619.546,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-04",6,4.95,224.31,,0.001,0.001,129.273,0.0592,0.01,0.0097,2175.531,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-05",11,9.9,470.34,,0.001,0.001,266.788,0.0591,0.017,0.018,4490.804,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-06",2,0.2,0,,0,0.001,1.236,0.059,0.001,0.09,20.864,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-08",1,0.37,0,,0,0.001,2.294,0.059,0.002,0.078,38.85,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-09",10,7.63,347.4,,0.001,0.001,200.385,0.0591,0.013,0.0111,3373.284,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-10",2,0.9,38.58,,0,0.001,22.446,0.0595,0.001,0.0045,377.306,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-11",4,2.98,131.55,,0,0.001,76.035,0.0593,0.005,0.011,1278.811,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-12",11,8.48,384.84,,0.001,0.001,219.724,0.0593,0.016,0.0143,3700.422,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-13",3,2.24,98.84,,0,0.001,57.146,0.0597,0.006,0.0133,960.974,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-14",4,2.99,135.11,,0,0.001,77.444,0.059,0.007,0.0143,1305.269,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-15",2,0.1,0,,0,0.001,0.587,0.0595,0,0.076,9.89,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-18",4,2.29,91.79,,0,0.001,54.392,0.059,0.012,0.041,915.72,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-20",4,2.99,132.34,,0,0.001,76.877,0.059,0.006,0.0365,1292.591,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-21",4,2.99,132.49,,0,0.001,77.108,0.0593,0.005,0.0088,1296.24,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-22",3,1.77,74.05,,0,0.001,43.238,0.0593,0.004,0.013,727.328,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-23",4,3.49,156.21,,0,0.001,90.557,0.059,0.008,0.011,1524.161,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-24",5,4.49,206.83,,0.001,0.001,119.701,0.059,0.005,0.0062,2013.51,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-27",7,4.99,221.18,,0.001,0.001,128.717,0.0591,0.005,0.0167,2166.053,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-28",4,2.49,111.12,,0,0.001,64.616,0.059,0.002,0.0243,1086.898,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-29",5,3.99,183.36,,0.001,0.001,107.044,0.059,0.004,0.0046,1801.603,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-06-30",6,5.87,276.41,,0.001,0.001,158.324,0.0592,0.008,0.006,2663.928,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-01",12,9.36,433.08,,0.001,0.001,248.272,0.0592,0.013,0.0158,4176.444,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-02",4,2.74,121.1,,0,0.001,69.796,0.0593,0.006,0.0388,1174.556,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-03",5,4.49,204.21,,0.001,0.001,117.868,0.0594,0.008,0.0088,1982.243,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-04",6,3.23,134.28,,0,0.001,78.631,0.0593,0.008,0.0152,1322.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-05",2,1.04,45.16,,0,0.001,26.204,0.0595,0.003,0.055,440.468,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-06",6,3.78,159.94,,0,0.001,93.323,0.0597,0.009,0.0137,1568.387,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-07",3,1.99,84.62,,0,0.001,49.115,0.059,0.006,0.0167,827.553,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-08",3,2.5,110.38,,0,0.001,64.19,0.059,0.004,0.0083,1080.928,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-09",5,4.74,214.95,,0.001,0.001,125,0.0592,0.007,0.0066,2103.17,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-10",8,7.24,332.36,,0.001,0.001,192.34,0.0593,0.009,0.006,3235.863,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-11",7,3.88,167.32,,0,0.001,98.49,0.0594,0.006,0.0083,1656.994,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-12",3,1.49,61.52,,0,0.001,36.162,0.06,0.003,0.013,607.575,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-14",5,2.91,119.87,,0,0.001,70.563,0.0594,0.007,0.0216,1186.495,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-15",2,1.49,61.96,,0,0.001,36.195,0.059,0.003,0.01,609.368,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-16",11,8.32,374.5,,0.001,0.001,215.28,0.0595,0.012,0.0166,3621.916,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-17",7,4.35,188.04,,0.001,0.001,108.987,0.0593,0.008,0.0171,1835.233,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-18",3,2.24,97.22,,0,0.001,56.66,0.059,0.003,0.0073,953.526,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-21",4,2.74,119.88,,0,0.001,69.282,0.0595,0.004,0.0093,1164.72,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-22",8,6.99,326.37,,0.001,0.001,186.096,0.059,0.013,0.0104,3132.569,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-24",4,3.24,146.73,,0,0.001,84.24,0.0593,0.005,0.007,1417.148,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-25",4,3.49,157.83,,0,0.001,90.867,0.0598,0.005,0.0065,1526.802,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-26",6,3.24,135.38,,0,0.001,78.94,0.0592,0.004,0.0083,1327.866,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-27",5,4.49,204.83,,0.001,0.001,118.578,0.0594,0.006,0.0066,1994.268,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-28",3,2.24,97.22,,0,0.001,56.922,0.0593,0.004,0.0087,957.008,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-29",5,3.99,181.74,,0.001,0.001,105.456,0.0592,0.004,0.005,1773.829,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-30",6,4.74,216.27,,0.001,0.001,124.632,0.0593,0.003,0.0042,2096.895,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-07-31",9,6.7,291.05,,0.001,0.001,169.265,0.0593,0.007,0.0069,2847.594,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-03",5,3.81,162.46,,0,0.001,95.228,0.0594,0.004,0.006,1601.521,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-04",3,1.74,75.01,,0,0.001,43.791,0.0593,0.002,0.008,736.357,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-05",3,1.99,86.74,,0,0.001,50.706,0.0593,0.002,0.0053,852.968,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-07",3,2.49,110.83,,0,0.001,64.439,0.059,0.003,0.0057,1085.478,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-08",3,1.99,87.11,,0,0.001,50.916,0.0593,0.002,0.0063,855.816,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-09",4,3.24,144.36,,0,0.001,84.127,0.059,0.003,0.004,1416.101,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-10",6,3.98,172.23,,0.001,0.001,100.367,0.0595,0.005,0.0072,1688.021,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-11",4,2.69,111.28,,0,0.001,65.836,0.0595,0.006,0.0128,1107.284,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-12",7,4.97,219.95,,0.001,0.001,126.794,0.059,0.01,0.0214,2133.617,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-13",9,8.24,381.84,,0.001,0.001,219.208,0.0592,0.008,0.0047,3689.832,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-14",11,9.24,421.88,,0.001,0.001,243.848,0.0593,0.007,0.0091,4102.712,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-15",9,7.24,327.76,,0.001,0.001,189.128,0.0591,0.005,0.0089,3183.624,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-16",4,2.65,115,,0,0.001,67.002,0.0593,0.002,0.006,1128.075,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-17",10,8.74,396,,0.001,0.001,228.404,0.0591,0.006,0.0038,3844.044,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-18",10,8.49,384.75,,0.001,0.001,221.867,0.0591,0.005,0.0075,3734.573,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-19",10,8.99,405.62,,0.001,0.001,233.627,0.0593,0.015,0.0084,3927.74,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-20",16,12.7,557.09,,0.002,0.001,321.932,0.0591,0.022,0.0184,5420.914,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-21",6,2.98,120.88,,0,0.001,71.428,0.059,0.006,0.0188,1201.436,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-22",6,2.78,111.55,,0,0.001,66.075,0.059,0.005,0.0238,1111.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-23",7,3.77,150.05,,0,0.001,88.949,0.059,0.006,0.0256,1497.797,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-24",5,3.99,176.62,,0.001,0.001,102.239,0.0594,0.005,0.006,1720.779,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-25",6,4.24,179.37,,0.001,0.001,105.215,0.0592,0.008,0.0123,1770.03,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-26",3,1.49,60.4,,0,0.001,35.653,0.0593,0.003,0.0147,599.968,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-27",8,4.97,207.06,,0.001,0.001,122.349,0.059,0.006,0.0191,2059.449,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-28",6,4.98,218.18,,0.001,0.001,127.677,0.059,0.007,0.0077,2149.124,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-03",3,1.74,72.88,,0,0.001,42.654,0.0593,0.003,0.0093,717.624,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-04",6,4.34,184.04,,0.001,0.001,108.365,0.0592,0.007,0.0077,1823.751,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-05",10,8.99,406.87,,0.001,0.001,236.563,0.059,0.01,0.0053,3981.399,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-06",5,3.24,141,,0,0.001,82.936,0.0592,0.004,0.0204,1394.944,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-08",3,1.65,69.4,,0,0.001,40.338,0.0597,0.003,0.0093,678.55,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-10",1,0.03,0,,0,0.001,0.171,0.06,0,0.011,2.859,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-11",4,3.62,167.42,,0,0.001,95.342,0.059,0.006,0.0073,1603.848,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-12",3,2.27,100.69,,0,0.001,58.155,0.059,0.003,0.0067,978.529,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-13",5,4.24,194.84,,0.001,0.001,111.784,0.0596,0.004,0.005,1878.858,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-14",5,3.49,157.12,,0,0.001,90.889,0.0592,0.004,0.0208,1529.705,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-15",4,2.74,122.84,,0,0.001,71.526,0.0595,0.004,0.024,1202.464,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-16",11,8.98,404.82,,0.001,0.001,235.418,0.0592,0.016,0.0229,3963.589,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-17",10,8.46,390.28,,0.001,0.001,227.57,0.0592,0.02,0.0116,3827.74,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-18",11,9.24,434.64,,0.001,0.001,249.452,0.0592,0.018,0.019,4198.016,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-19",9,8.49,395.83,,0.001,0.001,228.427,0.0591,0.005,0.0029,3844.213,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-20",4,3.24,147.46,,0,0.001,85.194,0.0593,0.002,0.003,1433.434,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-21",3,2.49,109.21,,0,0.001,63.606,0.0593,0.004,0.0067,1070.19,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-22",6,4.23,183.83,,0.001,0.001,106.908,0.0593,0.007,0.0083,1797.964,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-23",2,1.34,55.4,,0,0.001,32.94,0.059,0.004,0.0155,554.158,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-24",2,1.24,50.22,,0,0.001,30.07,0.059,0.002,0.0095,505.858,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-27",2,1.27,52.07,,0,0.001,30.731,0.0595,0.003,0.0105,517.046,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-28",3,2.49,108.96,,0,0.001,63.58,0.059,0.004,0.0087,1069.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-29",5,4.24,190.86,,0.001,0.001,110.827,0.0592,0.006,0.0086,1865.295,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-09-30",5,4.24,191.49,,0.001,0.001,112.014,0.0594,0.006,0.0062,1884.386,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-01",6,5.49,250.21,,0.001,0.001,145.031,0.0592,0.007,0.006,2440.235,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-02",5,4.24,191.36,,0.001,0.001,110.792,0.059,0.006,0.0066,1864.83,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-03",6,5.24,238.36,,0.001,0.001,137.005,0.059,0.007,0.0065,2306.345,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-04",7,5.49,254.12,,0.001,0.001,147.001,0.0591,0.008,0.0191,2474.284,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-05",10,7.98,361.1,,0.001,0.001,209.66,0.059,0.011,0.0175,3529.48,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-06",4,2.99,133.37,,0,0.001,77.607,0.059,0.005,0.008,1306.594,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-07",7,4.22,173.95,,0.001,0.001,103.15,0.0593,0.008,0.0107,1735.595,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-08",6,3.48,149.72,,0,0.001,87.118,0.0593,0.007,0.0245,1466.028,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-10",2,1.49,62.21,,0,0.001,36.208,0.059,0.003,0.009,608.719,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-11",3,1.99,85.49,,0,0.001,49.72,0.0593,0.003,0.0117,836.282,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-12",6,5.57,256.11,,0.001,0.001,145.606,0.0592,0.009,0.0078,2449.964,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-13",5,3.24,145.76,,0,0.001,84.764,0.0594,0.005,0.0198,1425.432,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-14",12,10.26,466.1,,0.001,0.001,270.262,0.0592,0.017,0.0091,4546.685,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-15",6,5.49,250.34,,0.001,0.001,144.843,0.0592,0.009,0.0073,2437.57,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-16",3,1.74,72.88,,0,0.001,43.042,0.0593,0.003,0.0113,723.792,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-17",3,2.03,86.59,,0,0.001,50.804,0.059,0.004,0.01,855.481,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-18",10,6.97,304.23,,0.001,0.001,177.096,0.0592,0.016,0.0119,2981.101,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-19",7,4.73,209.85,,0.001,0.001,121.604,0.0591,0.012,0.0301,2045.714,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-20",10,8.94,244.72,,0.001,0.001,164.538,0.0593,0.022,0.0292,2768.434,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-21",7,4.69,188.55,,0.001,0.001,112.268,0.059,0.01,0.0254,1891.502,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-22",9,5.35,231.76,,0.001,0.001,135.447,0.0593,0.011,0.0333,2277.795,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-23",4,2.74,123.01,,0,0.001,72.013,0.059,0.005,0.0088,1211.524,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-25",7,4.98,224.69,,0.001,0.001,130.499,0.0591,0.013,0.0336,2196.159,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-26",7,5.48,258.02,,0.001,0.001,148.258,0.059,0.011,0.0091,2495.428,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-27",4,2.49,115.51,,0,0.001,66.359,0.0593,0.004,0.0075,1116.115,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-28",9,5.22,232.33,,0.001,0.001,135.675,0.0592,0.01,0.0209,2281.889,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-29",3,2.24,100.46,,0,0.001,58.776,0.0593,0.004,0.0077,988.998,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-10-31",5,4.07,195.83,,0.001,0.001,113.023,0.059,0.007,0.008,1903.216,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-01",4,3.49,161.7,,0,0.001,94.383,0.0595,0.006,0.0083,1587.095,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-02",3,2.49,113.32,,0,0.001,66.457,0.059,0.004,0.0077,1117.825,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-03",2,1.49,64.32,,0,0.001,38.281,0.059,0.003,0.009,644.184,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-04",3,2.74,125.56,,0,0.001,73.54,0.0593,0.004,0.007,1236.041,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-05",10,7.09,320.13,,0.001,0.001,186.699,0.0593,0.012,0.0286,3139.313,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-06",8,5.36,235.41,,0.001,0.001,137.063,0.0594,0.01,0.0106,2305.832,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-08",3,1.49,65.63,,0,0.001,38.442,0.0593,0.003,0.0167,647.061,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-09",5,2.48,107.82,,0,0.001,63.29,0.0592,0.006,0.031,1065.018,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-10",4,3.49,166.43,,0,0.001,96.601,0.059,0.004,0.0065,1625.601,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-11",6,4.85,225.09,,0.001,0.001,129.888,0.0593,0.008,0.0108,2183.831,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-12",3,1.74,76.75,,0,0.001,45.072,0.0597,0.004,0.0133,758.283,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-14",3,1.24,53,,0,0.001,31.136,0.0597,0.003,0.046,523.256,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-15",5,2.48,105.71,,0,0.001,62.551,0.059,0.006,0.0254,1052.852,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-16",4,2.77,129.51,,0,0.001,75.975,0.0595,0.004,0.006,1277.233,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-20",3,1.99,90.35,,0,0.001,53.431,0.0597,0.001,0.002,898.265,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-21",5,3.74,177.84,,0.001,0.001,102.338,0.0594,0.001,0.0042,1720.716,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-22",5,3.99,190.35,,0.001,0.001,110.358,0.059,0.001,0.0016,1857.779,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-23",2,1.24,52.7,,0,0.001,31,0.059,0.002,0.0095,521.978,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-24",10,6.97,287.78,,0.001,0.001,171.696,0.0594,0.014,0.0154,2887.265,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-25",6,4.23,192.29,,0.001,0.001,111.097,0.0595,0.009,0.0105,1868.853,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-27",2,1.24,54.82,,0,0.001,31.948,0.059,0.003,0.0135,538.08,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-28",3,1.99,92.34,,0,0.001,53.705,0.059,0.005,0.0113,904.363,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-29",5,3.49,163.49,,0,0.001,94.25,0.0592,0.008,0.0208,1585.405,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-11-30",4,2.49,116.49,,0,0.001,67.67,0.0593,0.006,0.024,1139.534,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-01",11,9.74,460.22,,0.001,0.001,268.012,0.0591,0.015,0.0139,4509.882,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-02",7,3.97,170.8,,0.001,0.001,100.661,0.059,0.009,0.0157,1695.129,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-03",9,7.49,372.98,,0.001,0.001,211.358,0.0591,0.015,0.0169,3556.466,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-05",4,3.24,153.71,,0,0.001,88.902,0.0593,0.006,0.0083,1495.378,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-06",5,3.99,190.95,,0.001,0.001,109.606,0.0592,0.007,0.0184,1845.014,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-07",3,1.49,65.61,,0,0.001,38.584,0.059,0.004,0.0297,649.481,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-08",8,5.48,256.82,,0.001,0.001,146.396,0.0591,0.011,0.0171,2463.008,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-09",4,2.99,139.1,,0,0.001,79.912,0.059,0.007,0.0138,1346.018,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-10",4,2.74,119.95,,0,0.001,69.513,0.0593,0.008,0.0133,1169.978,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-11",8,6.98,330.87,,0.001,0.001,187.681,0.0594,0.014,0.0091,3155.764,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-12",6,4.49,213.61,,0.001,0.001,122.072,0.0592,0.01,0.0285,2054.885,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-14",3,1.74,78.58,,0,0.001,45.248,0.0593,0.003,0.0267,760.864,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-15",6,4.99,244.34,,0.001,0.001,139.93,0.0592,0.009,0.0082,2355.717,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-16",9,6.98,331.8,,0.001,0.001,190.453,0.059,0.014,0.019,3205.411,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-17",10,8.24,398,,0.001,0.001,228.036,0.0592,0.014,0.0198,3835.024,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-18",6,4.23,194.91,,0.001,0.001,112.694,0.059,0.01,0.0115,1897.285,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-19",2,1.49,66.43,,0,0.001,38.852,0.059,0.004,0.013,653.158,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-20",3,1.49,66.98,,0,0.001,39.107,0.0593,0.004,0.0537,658.204,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-27",3,1.27,54.38,,0,0.001,31.77,0.0597,0.003,0.0407,533.749,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Barre Generating Station",56474,"CT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-06",3,1.25,47.3,,0,0.001,28.353,0.0593,0.006,0.0113,476.67,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-07",3,1.25,44.3,,0,0.001,26.914,0.0597,0.004,0.0087,453.281,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-08",3,1.34,41.88,,0,0.001,25.924,0.0597,0.005,0.011,435.812,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-09",6,2.68,89.76,,0,0.001,54.816,0.059,0.007,0.0085,922.52,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-10",5,2.69,89.36,,0,0.001,54.744,0.0594,0.007,0.0096,920.155,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-11",3,1.32,42.7,,0,0.001,26.244,0.0593,0.004,0.01,441.926,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-13",3,1.32,43.7,,0,0.001,26.514,0.059,0.005,0.011,447.106,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-28",3,1.34,45.56,,0,0.001,27.848,0.059,0.004,0.008,469.07,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-29",3,1.34,42.88,,0,0.001,26.654,0.0593,0.005,0.0103,447.87,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-01-31",3,1.25,23.84,,0,0.001,17.78,0.0597,0.002,0.0077,298.968,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-03",4,2.35,87.97,,0,0.001,52.103,0.0595,0.006,0.009,876.676,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-04",5,3.4,127.26,,0,0.001,75.198,0.0594,0.004,0.031,1264.163,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-05",3,1.34,45.88,,0,0.001,27.804,0.06,0.003,0.0077,467.138,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-06",9,5.54,234.5,,0.001,0.001,134.586,0.0592,0.01,0.0073,2264.742,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-07",3,1.34,39.88,,0,0.001,24.796,0.0593,0.003,0.0077,417.026,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-08",4,2.34,92.56,,0,0.001,53.774,0.0593,0.004,0.0068,905.646,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-09",12,5.18,95.92,,0,0.001,70.648,0.0593,0.01,0.0238,1188.586,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-23",3,1.34,41.56,,0,0.001,25.934,0.0597,0.005,0.012,436.944,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-27",3,1.34,36.24,,0,0.001,23.802,0.059,0.004,0.009,400.09,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-28",8,4.63,145.76,,0,0.001,91.405,0.0594,0.006,0.015,1537.244,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-02-29",6,2.62,70.96,,0,0.001,46.456,0.0597,0.005,0.0192,780.606,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-01",9,4.68,128.22,,0,0.001,82.708,0.0592,0.011,0.0113,1392.818,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-03",3,1.87,58.62,,0,0.001,36.405,0.0593,0.007,0.0197,613.117,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-08",3,1.25,23.84,,0,0.001,17.474,0.06,0.004,0.0117,293.292,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-11",3,1.35,47.97,,0,0.001,29.064,0.059,0.004,0.008,489.852,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-12",3,1.25,25.84,,0,0.001,18.341,0.0593,0.004,0.0123,309.374,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-13",4,2.25,46.84,,0,0.001,32.918,0.06,0.006,0.013,552.543,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-14",3,1.24,23.54,,0,0.0007,17.018,0.0587,0.002,0.0073,286.672,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-18",7,4.5,187.51,,0.001,0.001,107.545,0.0594,0.018,0.0219,1807.642,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-22",1,0.1,0,,0,0.001,0.6,0.06,0,0.095,10.07,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-27",2,1.6,54.9,,0,0.001,33.75,0.059,0.003,0.009,568.23,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-28",5,2.18,33.93,,0,0.001,28.408,0.0592,0.006,0.0342,478.97,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-29",6,2.58,49.26,,0,0.001,36.817,0.0595,0.005,0.0215,619.661,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-03-31",1,0.82,10.66,,0,0.001,9.43,0.059,0.003,0.039,159.08,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-01",7,3.98,69.61,,0,0.001,54.418,0.0596,0.006,0.0171,915.851,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-03",1,0.62,8.06,,0,0.001,7.13,0.059,0.001,0.016,120.032,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-04",5,2,31.04,,0,0.001,25.544,0.0594,0.005,0.018,430.253,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-05",12,6.4,105.18,,0,0.001,85.279,0.0595,0.012,0.0144,1433.863,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-06",5,2.33,71.97,,0,0.001,45.824,0.0594,0.01,0.0292,770.67,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-07",14,12.21,419.82,,0.001,0.001,256.581,0.0592,0.019,0.0089,4317.925,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-08",9,4.55,99.64,,0,0.001,70.026,0.0592,0.008,0.013,1178.225,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-09",10,8.34,319.7,,0.001,0.001,190.818,0.0595,0.008,0.0049,3209.656,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-10",3,2.07,77.67,,0,0.001,46.133,0.059,0.003,0.0073,776.918,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-11",3,1.5,49.16,,0,0.0007,30.58,0.0593,0.002,0.0047,514.542,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-12",14,10.06,359.99,,0.001,0.001,220.029,0.0593,0.019,0.0083,3702.393,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-13",3,2.4,86.05,,0,0.001,52.144,0.0593,0.002,0.005,877.257,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-14",3,1.47,49.75,,0,0.001,30.824,0.059,0.004,0.008,518.973,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-15",2,0.82,17.19,,0,0.001,12.58,0.0595,0.002,0.0165,211.366,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-16",4,2.49,91.99,,0,0.001,55.39,0.059,0.005,0.0075,932.076,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-17",3,1.5,50.68,,0,0.001,30.974,0.059,0.005,0.009,521.238,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-18",3,1.39,38.33,,0,0.001,24.986,0.0593,0.005,0.0107,421.209,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-19",6,3.07,59.95,,0,0.001,44.522,0.0593,0.004,0.0132,749.078,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-25",3,1.34,24.56,,0,0.001,18.6,0.0593,0.001,0.006,312.896,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-26",5,3.45,111.59,,0,0.001,70.528,0.0594,0.003,0.0052,1185.931,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-28",3,2.07,52.59,,0,0.001,35.685,0.0593,0.002,0.008,599.75,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-04-30",3,1.34,43.2,,0,0.001,27.128,0.059,0.002,0.005,456.526,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-01",3,1.45,51.31,,0,0.001,31.379,0.059,0.001,0.0033,528.979,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-04",5,2.94,97.74,,0,0.001,61.14,0.0594,0.003,0.0058,1028.563,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-05",11,9.3,383.52,,0.001,0.001,227.288,0.0593,0.009,0.0046,3824.114,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-06",5,2.69,82.56,,0,0.001,52.74,0.0592,0.003,0.0058,887.55,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-07",5,2.41,75.45,,0,0.001,47.601,0.0596,0.008,0.0944,800.086,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-08",2,0.94,25.15,,0,0.001,16.538,0.0595,0.004,0.021,277.973,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-28",3,1.35,44.64,,0,0.001,27.965,0.0593,0.005,0.0093,470.993,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-29",9,5.73,222.87,,0.001,0.001,134.094,0.0593,0.008,0.0254,2255.718,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-01",5,3.25,122.3,,0,0.001,73.948,0.0594,0.003,0.0052,1244.295,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-02",5,3.54,77.88,,0,0.001,53.998,0.0594,0.003,0.0054,908.054,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-03",5,3.27,133,,0,0.001,79.249,0.0596,0.004,0.005,1332.659,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-04",11,9.22,411.8,,0.001,0.001,237.692,0.0595,0.013,0.0062,3998.03,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-08",4,2.25,89.3,,0,0.001,53.777,0.059,0.002,0.0058,904.735,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-09",3,1.34,41.24,,0,0.001,26.558,0.0593,0.003,0.0073,447.114,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-10",4,2.3,65.68,,0,0.001,42.754,0.0595,0.004,0.0078,718.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-11",12,8.56,361.88,,0.001,0.001,212.27,0.0593,0.016,0.0073,3574.046,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-14",3,1.34,24.24,,0,0.001,18.454,0.0593,0.001,0.0077,310.534,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-27",2,0.64,4.34,,0,0.001,5.89,0.059,0.001,0.01,99.128,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-04",4,1.45,22.8,,0,0.001,18.885,0.0593,0.002,0.0095,317.634,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-05",5,4.1,82.25,,0,0.001,60.737,0.0594,0.005,0.0112,1022.654,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-07",2,1.15,30.32,,0,0.001,20.141,0.0595,0.001,0.0065,338.948,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-09",4,2.34,56.24,,0,0.001,39.542,0.0598,0.002,0.0063,664.894,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-10",9,7.45,306.01,,0.001,0.001,180.346,0.0592,0.01,0.0087,3034.329,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-11",7,5.27,167,,0.001,0.001,106.09,0.0599,0.006,0.0061,1781.752,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-12",8,6.25,170.84,,0.001,0.001,112.121,0.0591,0.006,0.006,1888.002,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-13",5,3.22,72,,0,0.001,50.59,0.059,0.002,0.0042,852.106,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-14",3,1.25,27.84,,0,0.001,19.395,0.0597,0.002,0.008,325.753,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-15",3,1.2,22.9,,0,0.001,17.104,0.0597,0.003,0.0107,287.738,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-16",3,1.25,24.84,,0,0.001,18.132,0.0593,0.003,0.011,304.948,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-17",3,1.32,46.7,,0,0.001,28.418,0.059,0.003,0.008,479.072,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-18",3,1.25,46.3,,0,0.001,28.031,0.059,0.003,0.0067,471.603,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-19",3,1.32,46.7,,0,0.001,28.93,0.0597,0.004,0.0087,486.814,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-20",3,1.27,46.5,,0,0.001,28.426,0.0597,0.004,0.0083,478.414,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-27",3,1.42,40.2,,0,0.001,26.394,0.0597,0.004,0.01,443.492,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-28",3,1.22,41.8,,0,0.001,25.87,0.0593,0.002,0.0063,435.118,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-29",6,4.27,154,,0,0.001,93.266,0.0595,0.008,0.0078,1569.019,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-30",9,7.25,213.84,,0.001,0.001,136.682,0.0593,0.008,0.0064,2299.893,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-07-31",9,7.58,178.89,,0.001,0.001,123.966,0.0594,0.007,0.0086,2085.225,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-01",3,1.3,42.52,,0,0.001,26.624,0.0593,0.001,0.0067,448.232,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-02",4,2.32,85.4,,0,0.001,51.806,0.059,0.006,0.0085,871.622,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-03",6,3.22,100.4,,0,0.001,63.56,0.059,0.008,0.0128,1069.402,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-04",3,1.34,43.56,,0,0.001,27.146,0.0593,0.001,0.007,456.57,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-05",2,0.78,12.9,,0,0.001,10.164,0.0595,0.002,0.033,170.808,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-11",3,1.25,42.3,,0,0.001,26.212,0.0593,0.002,0.0097,441.042,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-12",5,3.35,111.97,,0,0.001,69.307,0.0594,0.004,0.0072,1165.484,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-13",7,6.23,214.29,,0.001,0.001,131.297,0.059,0.009,0.0087,2209.672,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-14",11,9.97,371.3,,0.001,0.001,223.464,0.0592,0.016,0.008,3760.299,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-15",9,4.71,116.27,,0,0.001,78.891,0.0593,0.008,0.0088,1327.694,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-16",2,1.18,22.21,,0,0.001,16.672,0.0595,0.001,0.006,280.81,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-17",12,8.89,343.06,,0.001,0.001,202.975,0.0593,0.017,0.0088,3416.468,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-18",10,8.34,350.08,,0.001,0.001,205.74,0.059,0.012,0.0071,3464.718,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-19",4,2.5,52.5,,0,0.001,37.79,0.0593,0.002,0.007,636.57,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-20",2,1.08,18.9,,0,0.001,14.907,0.0595,0.003,0.014,251.133,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-21",2,0.64,2.48,,0,0.001,5.04,0.06,0.002,0.02,84.666,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-22",4,2.58,63.65,,0,0.001,43.477,0.0595,0.003,0.0143,731.156,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-23",8,6.03,169.58,,0.001,0.001,110.756,0.0591,0.007,0.0066,1864.844,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-24",9,4.95,118.09,,0,0.001,81.42,0.0596,0.008,0.0084,1370.289,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-25",10,5.9,147.61,,0.001,0.001,99.646,0.0594,0.008,0.0072,1677.312,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-26",10,6.83,177.04,,0.001,0.001,118.759,0.0596,0.008,0.0074,1997.467,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-27",9,7.22,257,,0.001,0.001,157.696,0.0592,0.007,0.0054,2652.526,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-28",7,5.27,151.75,,0,0.001,98.505,0.0593,0.006,0.007,1658.683,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-29",2,0.94,30.36,,0,0.001,19.374,0.059,0.004,0.011,326.418,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-30",4,2.3,91.52,,0,0.001,55.75,0.059,0.002,0.0048,938.672,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-08-31",3,1.34,46.88,,0,0.001,29,0.0593,0.004,0.008,488.698,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-01",4,2.29,93.7,,0,0.001,56.28,0.0593,0.006,0.0085,947.496,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-03",6,4.25,180.53,,0.001,0.001,105.889,0.0593,0.007,0.0065,1783.397,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-04",10,8.25,363.3,,0.001,0.001,210.212,0.0594,0.014,0.007,3536.72,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-05",4,2.82,85.56,,0,0.001,54.405,0.0593,0.005,0.0128,915.767,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-06",4,2.25,78,,0,0.001,47.96,0.0593,0.004,0.0265,807.935,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-07",8,4.6,136.81,,0,0.001,87.732,0.0596,0.007,0.0074,1474.791,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-08",9,5.49,222.17,,0.001,0.001,131.524,0.0594,0.007,0.0052,2213.298,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-09",4,2.25,76.84,,0,0.001,47.434,0.0595,0.005,0.0073,797.911,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-10",4,2.35,92.97,,0,0.001,56.205,0.0593,0.004,0.0065,945.13,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-11",4,2.32,90.7,,0,0.001,54.27,0.0593,0.004,0.007,913.222,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-12",3,1.25,46.3,,0,0.001,28.008,0.059,0.003,0.007,470.897,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-13",5,3.32,140.7,,0,0.001,82.4,0.0592,0.007,0.0082,1386.03,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-14",5,3.25,140.3,,0,0.001,81.44,0.0594,0.005,0.0074,1369.573,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-15",6,4.34,177.56,,0.001,0.001,106.092,0.0592,0.005,0.0055,1786.992,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-16",7,5.17,225.27,,0.001,0.001,132.905,0.0591,0.008,0.0064,2236.132,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-17",14,9.99,383.95,,0.001,0.001,231.335,0.0591,0.014,0.0065,3896.787,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-18",10,6.15,219.3,,0.001,0.001,134.227,0.0595,0.012,0.0098,2256.95,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-19",4,2.35,86.97,,0,0.001,52.556,0.0595,0.004,0.0085,883.865,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-21",14,9.78,282.51,,0.001,0.001,183.578,0.0592,0.017,0.0121,3090.145,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-22",18,12.1,384.96,,0.001,0.001,243.349,0.0594,0.02,0.0174,4093.477,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-23",15,11.12,303.79,,0.001,0.001,202.487,0.0592,0.018,0.0137,3408.223,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-24",19,12.03,358.48,,0.001,0.001,230.351,0.0594,0.021,0.0232,3875.173,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-25",19,13.79,380.92,,0.001,0.001,249.826,0.0594,0.02,0.0133,4202.399,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-26",12,9.85,371.23,,0.001,0.001,224.471,0.0593,0.015,0.011,3776.213,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-27",12,8.71,289.99,,0.001,0.001,181.967,0.0595,0.014,0.0185,3059.776,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-28",12,8.8,254.37,,0.001,0.001,165.345,0.0593,0.012,0.0197,2781.451,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-29",11,8.86,297.4,,0.001,0.001,183.811,0.0595,0.013,0.0187,3092.284,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-09-30",9,8.03,274.71,,0.001,0.001,169.952,0.0593,0.01,0.0077,2859.521,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-01",9,6.91,197.03,,0.001,0.001,127.416,0.0592,0.009,0.0099,2146.253,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-13",4,1.53,47.93,,0,0.001,29.722,0.0593,0.004,0.0635,499.646,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-14",9,8.7,208.69,,0.001,0.001,144.2,0.059,0.014,0.0113,2427.466,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-15",14,10.09,285.57,,0.001,0.001,185.243,0.0591,0.025,0.0189,3118.722,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-16",6,4.3,175.24,,0.001,0.001,102.784,0.0593,0.007,0.0072,1727.758,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-17",7,3.29,101.45,,0,0.001,64.576,0.0594,0.009,0.0267,1085.904,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-18",9,5.73,119.85,,0,0.001,86.876,0.0593,0.01,0.014,1461.973,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-19",2,0.44,12.18,,0,0.001,7.85,0.059,0.005,0.0385,132.176,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-20",1,0.38,8.36,,0,0.001,5.852,0.059,0.004,0.072,98.458,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-21",5,3.48,85.2,,0,0.001,57.7,0.0594,0.005,0.0128,972.772,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-22",4,2.67,89.03,,0,0.001,54.567,0.0595,0.005,0.011,918.068,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-23",3,1.24,23.1,,0,0.001,17.196,0.0593,0.004,0.0273,289.038,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-24",2,1.02,43,,0,0.001,24.782,0.059,0.004,0.0345,416.888,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-25",15,9.59,338.02,,0.001,0.001,202.31,0.0592,0.02,0.0151,3406.011,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-26",9,5.85,222.24,,0.001,0.001,130.479,0.0591,0.012,0.0262,2195.938,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-27",4,2.29,84.89,,0,0.001,50.473,0.0593,0.005,0.009,849.666,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-28",5,1.94,45.1,,0,0.001,30.944,0.0592,0.006,0.0372,521.308,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-29",8,4.81,148.2,,0,0.001,92.397,0.0595,0.015,0.0229,1554.863,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-30",3,1.32,41.4,,0,0.001,25.518,0.0593,0.003,0.0093,429.728,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-10-31",5,2.62,78.66,,0,0.001,49.803,0.0598,0.006,0.0198,837.663,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-01",8,6.59,251.56,,0.001,0.001,148.484,0.0594,0.01,0.0075,2497.181,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-02",3,1.27,42.25,,0,0.001,25.852,0.059,0.004,0.01,434.663,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-03",7,3.52,95.59,,0,0.001,61.943,0.0591,0.013,0.0247,1042.926,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-04",5,2.5,89.79,,0,0.001,53.794,0.0592,0.01,0.0348,905.898,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-05",7,2.92,60.78,,0,0.001,43.412,0.0593,0.012,0.0321,731.278,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-06",11,8.49,244.61,,0.001,0.001,153.344,0.0592,0.008,0.0085,2583.981,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-11",3,1.32,23.8,,0,0.001,17.568,0.0593,0.002,0.008,295.362,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-12",3,1.25,23.61,,0,0.001,17.087,0.0593,0.002,0.009,287.601,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-14",3,1.3,23.68,,0,0.001,17.732,0.0593,0.002,0.0087,297.556,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-22",3,1.25,23.84,,0,0.001,17.219,0.059,0.003,0.0097,289.657,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-27",1,0.52,4.16,,0,0.001,5.044,0.059,0.002,0.038,84.864,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-01",6,4.34,151.88,,0,0.001,92.202,0.0593,0.021,0.0333,1552.394,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-03",10,8.2,356.9,,0.001,0.001,206.394,0.0594,0.015,0.0132,3473.65,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-10",1,0.27,5.67,,0,0.001,4.077,0.059,0.001,0.028,68.607,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-15",7,3.55,104.72,,0,0.001,65.094,0.0593,0.009,0.012,1094.359,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-16",3,1.39,25.7,,0,0.001,18.689,0.059,0.004,0.013,315.239,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-19",3,1.25,23.84,,0,0.001,17.461,0.0593,0.003,0.0103,293.338,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-20",4,2.25,73.84,,0,0.001,44.228,0.059,0.004,0.0073,744.954,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-24",3,1.27,28.25,,0,0.001,18.766,0.0593,0.007,0.0437,316.581,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-26",9,4.11,145.88,,0,0.001,86.705,0.0594,0.017,0.0343,1458.438,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-27",3,1.24,40.98,,0,0.001,24.71,0.0593,0.004,0.0357,415.438,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Center Generating Station",56475,"CT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-01",24,24,4958,,0.011,0.001,2127,0.059,0.107,0.006,35789.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-02",24,24,5584,,0.012,0.001,2371,0.059,0.119,0.006,39899.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-03",24,24,5240,,0.011,0.001,2239.7,0.059,0.112,0.006,37686.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-04",24,23.2,5071.6,,0.011,0.001,2162.88,0.059,0.111,0.0069,36393.44,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-06",24,23.67,5257.44,,0.012,0.001,2281.086,0.059,0.21,0.0197,38380.706,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-07",24,24,6082,,0.013,0.001,2594.6,0.059,0.128,0.0058,43656,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-08",24,24,5768,,0.012,0.001,2468.2,0.059,0.118,0.0057,41531.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-09",24,24,5853,,0.012,0.001,2463.3,0.059,0.118,0.0057,41447.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-10",24,24,6212,,0.013,0.001,2607.2,0.059,0.126,0.0058,43869.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-11",24,24,5314,,0.011,0.001,2265.8,0.059,0.113,0.0059,38127.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-12",24,24,5202,,0.011,0.001,2221.7,0.059,0.111,0.006,37383.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-13",24,24,5600,,0.012,0.001,2386.2,0.059,0.118,0.0059,40151.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-14",24,24,5678,,0.012,0.001,2406.3,0.059,0.116,0.0058,40490.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-15",24,24,5804,,0.012,0.001,2462.8,0.059,0.12,0.0058,41444.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-16",24,24,5530,,0.012,0.001,2354.2,0.059,0.113,0.0057,39614.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-17",24,24,5467,,0.012,0.001,2337.4,0.059,0.115,0.0059,39332.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-18",24,24,5205,,0.011,0.001,2233.2,0.059,0.112,0.006,37573.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-19",24,24,5343,,0.012,0.001,2280.4,0.059,0.11,0.0057,38370.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-20",24,24,5471,,0.012,0.001,2323.4,0.059,0.113,0.0058,39095.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-21",24,24,5126,,0.011,0.001,2193.5,0.059,0.111,0.006,36911.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-22",24,24,5365,,0.012,0.001,2283.7,0.059,0.115,0.006,38423.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-23",24,24,5645,,0.012,0.001,2392.2,0.059,0.117,0.0058,40251.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-24",24,24,5418,,0.012,0.001,2307.2,0.059,0.11,0.0057,38824.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-25",24,24,5040,,0.011,0.001,2162.8,0.059,0.105,0.0058,36391.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-26",24,24,4690,,0.01,0.001,2032.7,0.059,0.101,0.0059,34201.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-27",24,24,5147,,0.011,0.001,2208.7,0.059,0.107,0.0058,37167.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-28",24,24,5262,,0.011,0.001,2251.7,0.059,0.111,0.0059,37887.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-29",24,24,5617,,0.012,0.001,2379,0.059,0.116,0.0058,40032.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-30",24,24,5313,,0.011,0.001,2268.7,0.059,0.111,0.0058,38175.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-01-31",24,24,5202,,0.011,0.001,2219.9,0.059,0.112,0.006,37357.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-01",24,24,5191,,0.011,0.001,2220.8,0.059,0.11,0.0059,37369.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-02",24,24,4915,,0.011,0.001,2109,0.059,0.102,0.0058,35489.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-03",24,24,5357,,0.012,0.001,2284.6,0.059,0.111,0.0058,38443.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-04",24,24,5765,,0.012,0.001,2447.7,0.059,0.124,0.006,41187.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-05",24,24,5726,,0.012,0.001,2427.6,0.059,0.119,0.0058,40845.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-06",24,24,5342,,0.012,0.001,2284.5,0.059,0.111,0.0058,38436.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-07",24,24,5429,,0.012,0.001,2313.1,0.059,0.116,0.006,38919,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-08",24,23.45,4967.6,,0.011,0.001,2135.225,0.059,0.108,0.0062,35925.875,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-10",20,19.17,3923.04,,0.009,0.001,1699.841,0.059,0.142,0.0205,28603.498,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-11",24,24,5345,,0.011,0.001,2278,0.059,0.113,0.0059,38327.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-12",24,24,5855,,0.013,0.001,2480.3,0.059,0.123,0.0059,41738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-13",24,24,5752,,0.012,0.001,2435.6,0.059,0.118,0.0058,40986.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-14",24,24,5375,,0.012,0.001,2293.6,0.059,0.115,0.006,38594.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-15",24,24,5283,,0.011,0.001,2254.1,0.059,0.11,0.0058,37924.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-16",24,24,5008,,0.011,0.001,2145,0.059,0.108,0.006,36093.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-17",24,24,5279,,0.011,0.001,2242.7,0.059,0.112,0.006,37738.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-18",24,24,5431,,0.012,0.001,2311.8,0.059,0.116,0.006,38900.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-19",24,24,5449,,0.012,0.001,2320.3,0.059,0.116,0.006,39041.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-20",24,24,5503,,0.012,0.001,2341.8,0.059,0.116,0.0059,39403.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-21",24,24,5391,,0.012,0.001,2289.3,0.059,0.114,0.0059,38524.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-22",24,23.43,4839.32,,0.01,0.001,2072.653,0.059,0.104,0.0061,34876.169,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-24",19,18.38,4063.5,,0.009,0.001,1752.782,0.059,0.131,0.0166,29495.662,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-25",24,24,5506,,0.012,0.001,2341.1,0.059,0.117,0.0059,39393.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-26",24,24,5518,,0.012,0.001,2348.5,0.059,0.119,0.006,39515.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-27",24,24,5528,,0.012,0.001,2347.9,0.059,0.118,0.006,39506.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-28",24,23.43,5106.02,,0.011,0.001,2181.933,0.059,0.109,0.0061,36714.803,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-02",21,20.28,4422.76,,0.01,0.001,1909.328,0.059,0.162,0.0206,32122.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-03",24,24,5474,,0.012,0.001,2328.3,0.059,0.118,0.006,39179.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-04",24,24,5492,,0.012,0.001,2329,0.059,0.118,0.006,39185.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-05",24,24,5471,,0.012,0.001,2336.7,0.059,0.115,0.0058,39316.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-06",24,24,5743,,0.012,0.001,2426,0.059,0.124,0.0061,40821.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-07",24,24,5713,,0.012,0.001,2419.8,0.059,0.129,0.0063,40716.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-08",24,24,5709,,0.012,0.001,2413.4,0.059,0.127,0.0062,40608.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-09",24,24,5828,,0.012,0.001,2468.7,0.059,0.125,0.006,41541.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-10",24,24,5739,,0.012,0.001,2431.9,0.059,0.123,0.006,40919.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-11",24,24,5607,,0.012,0.001,2379.8,0.059,0.119,0.0059,40045,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-12",24,24,5764,,0.012,0.001,2435.2,0.059,0.122,0.006,40981.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-13",24,24,5603,,0.012,0.001,2375.8,0.059,0.116,0.0058,39976.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-14",24,24,5413,,0.012,0.001,2299.6,0.059,0.116,0.006,38699,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-15",24,24,5489,,0.012,0.001,2338.9,0.059,0.12,0.0061,39356.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-16",24,24,6105,,0.013,0.001,2595.7,0.059,0.136,0.0062,43677.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-17",24,24,5852,,0.013,0.001,2491.2,0.059,0.131,0.0062,41919.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-18",24,24,5658,,0.012,0.001,2405,0.059,0.124,0.0061,40469,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-19",24,24,5657,,0.012,0.001,2406.6,0.059,0.124,0.0061,40498.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-20",24,24,5859,,0.013,0.001,2488.9,0.059,0.127,0.0061,41883.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-21",24,24,5837,,0.013,0.001,2482,0.059,0.129,0.0062,41764.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-22",24,24,5728,,0.012,0.001,2428.9,0.059,0.123,0.006,40873.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-23",24,24,5494,,0.012,0.001,2331.4,0.059,0.118,0.006,39232.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-24",24,24,5747,,0.012,0.001,2433.7,0.059,0.125,0.0061,40953.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-25",24,24,5642,,0.012,0.001,2387.1,0.059,0.122,0.0061,40167.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-26",8,7.62,1685.28,,0.004,0.001,723.914,0.059,0.041,0.0071,12179.916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-28",7,6.32,1173.72,,0.003,0.001,528.668,0.059,0.107,0.0524,8896.568,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-29",3,2.98,645.16,,0.001,0.001,273.53,0.059,0.025,0.0113,4601.906,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-30",1,0.37,8.51,,0,0.001,12.025,0.059,0.016,0.16,202.575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-03-31",23,22.43,4753.44,,0.01,0.001,2053.376,0.059,0.15,0.011,34549.862,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-27",4,3.69,61.94,,0.001,0.001,126.498,0.0593,0.163,0.1585,2127.145,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-28",10,9.23,1977.22,,0.004,0.001,856.979,0.0591,0.079,0.0277,14419.178,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-29",22,21.7,4341.7,,0.009,0.001,1863.86,0.059,0.094,0.006,31360.58,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-07",9,7.97,1570.75,,0.004,0.001,704.063,0.059,0.076,0.025,11845.383,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-08",7,6.55,1359.09,,0.003,0.001,590.416,0.059,0.057,0.018,9934.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-24",9,8.5,1579.5,,0.004,0.001,705.3,0.059,0.108,0.0399,11866.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-25",24,24,4503,,0.01,0.001,1973.5,0.059,0.095,0.0057,33206.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-26",24,24,5089,,0.011,0.001,2191,0.059,0.108,0.0058,36866.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-27",24,24,5081,,0.011,0.001,2187.7,0.059,0.107,0.0058,36811.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-28",24,23.27,4885.38,,0.011,0.001,2095.287,0.059,0.104,0.0062,35255.787,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-29",12,11.69,2159.3,,0.005,0.001,963.236,0.059,0.13,0.0298,16208.654,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-30",24,23.1,3512.2,,0.008,0.001,1673.27,0.059,0.117,0.014,28157,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-05-31",24,24,3867,,0.009,0.001,1813.2,0.059,0.082,0.0053,30506.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-01",24,24,4636,,0.01,0.001,2074.2,0.059,0.101,0.0058,34905.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-02",24,24,5469,,0.012,0.001,2327.1,0.059,0.114,0.0058,39159.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-03",24,24,5703,,0.012,0.001,2429.6,0.059,0.117,0.0057,40886.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-04",24,24,5583,,0.012,0.001,2385.4,0.059,0.117,0.0058,40143.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-05",24,23.88,5090.48,,0.011,0.001,2163.128,0.059,0.112,0.0064,36401.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-08",15,14.08,2576,,0.006,0.001,1188.248,0.059,0.198,0.0427,19992.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-09",22,20.93,4495.95,,0.01,0.001,1944.255,0.059,0.603,0.0514,32718.129,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-10",24,24,5445,,0.012,0.001,2319.1,0.059,0.112,0.0058,39022.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-11",24,24,5512,,0.012,0.001,2351.6,0.059,0.115,0.0058,39567.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-12",7,6.9,1430.5,,0.003,0.001,600.8,0.059,0.037,0.0077,10110.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-15",15,14.13,2323.03,,0.005,0.001,1084.288,0.059,0.232,0.049,18245.267,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-17",14,13.85,2358.75,,0.006,0.001,1094.88,0.059,0.187,0.0376,18421.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-18",24,24,5246,,0.011,0.001,2222.8,0.059,0.109,0.0058,37401.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-19",24,23.67,5147.54,,0.011,0.001,2185.723,0.059,0.113,0.0065,36781.418,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-20",4,3.38,196.94,,0.001,0.001,145.842,0.059,0.111,0.1263,2454.576,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-21",24,24,4190,,0.01,0.001,1905.5,0.059,0.092,0.0057,32065.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-22",24,24,5573,,0.012,0.001,2367.2,0.059,0.118,0.0059,39834.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-23",16,14.56,3064.6,,0.007,0.001,1354.368,0.059,0.159,0.0328,22786.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-24",24,24,5328,,0.011,0.001,2260,0.059,0.112,0.0059,38032.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-25",24,24,5377,,0.012,0.001,2281.5,0.059,0.113,0.0059,38389.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-26",24,23.45,5022.75,,0.011,0.001,2154.575,0.059,0.108,0.006,36258.085,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-27",11,10.18,2333.16,,0.005,0.001,1012.752,0.059,0.089,0.0229,17038.528,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-28",2,1.25,228,,0.001,0.001,99.575,0.059,0.006,0.0115,1674.825,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-29",9,8.17,1717.7,,0.004,0.001,749.397,0.059,0.09,0.0359,12608.269,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-06-30",24,23.78,5049.12,,0.011,0.001,2144.13,0.059,0.113,0.0066,36080.13,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-05",10,9.5,1935.5,,0.004,0.001,837.65,0.059,0.107,0.0352,14097.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-06",24,24,5165,,0.011,0.001,2204.6,0.059,0.107,0.0058,37092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-07",24,24,4870,,0.011,0.001,2108.6,0.059,0.104,0.0059,35478.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-08",24,24,4558,,0.01,0.001,1967.8,0.059,0.093,0.0056,33110.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-09",24,24,4708,,0.01,0.001,2075.2,0.059,0.1,0.0058,34917.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-10",24,24,5143,,0.011,0.001,2219.3,0.059,0.11,0.0059,37348,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-11",24,24,5338,,0.012,0.001,2279.7,0.059,0.113,0.0059,38359.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-12",24,24,5174,,0.011,0.001,2192,0.059,0.108,0.0058,36887.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-13",24,24,5227,,0.011,0.001,2215.7,0.059,0.109,0.0059,37281.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-14",24,24,5277,,0.011,0.001,2223,0.059,0.107,0.0057,37404.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-15",24,24,4549,,0.01,0.001,2019.9,0.059,0.096,0.0056,33985.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-16",24,24,5221,,0.011,0.001,2191.2,0.059,0.109,0.0059,36872.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-17",24,24,4666,,0.01,0.001,2037.1,0.059,0.099,0.0058,34281.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-18",24,24,4997,,0.011,0.001,2167,0.059,0.107,0.0058,36465.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-19",24,24,4456,,0.01,0.001,1974.5,0.059,0.092,0.0055,33223.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-20",24,24,5226,,0.011,0.001,2207.2,0.059,0.1,0.0054,37140.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-21",24,24,5404,,0.012,0.001,2280.8,0.059,0.105,0.0054,38379.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-22",24,24,4422,,0.01,0.001,1931.1,0.059,0.092,0.0056,32496.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-23",24,23.73,4680.15,,0.01,0.001,2029.507,0.059,0.093,0.0055,34149.183,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-24",9,8.82,1977.38,,0.004,0.001,845.88,0.059,0.061,0.0143,14231.584,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-25",24,24,5146,,0.011,0.001,2147.2,0.059,0.097,0.0054,36132.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-26",24,24,5029,,0.011,0.001,2172.5,0.059,0.101,0.0055,36555.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-27",24,24,5438,,0.012,0.001,2304.4,0.059,0.107,0.0055,38772.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-28",24,24,5643,,0.012,0.001,2380.1,0.059,0.112,0.0055,40050,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-29",24,24,5645,,0.012,0.001,2402.4,0.059,0.113,0.0056,40421.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-30",24,24,5501,,0.012,0.001,2330.7,0.059,0.11,0.0056,39217.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-07-31",24,24,5657,,0.012,0.001,2438.9,0.059,0.118,0.0057,41041.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-01",24,24,5322,,0.012,0.001,2288.5,0.059,0.111,0.0058,38510.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-02",24,24,4771,,0.011,0.001,2083.2,0.059,0.1,0.0057,35052.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-03",24,24,4671,,0.01,0.001,2039,0.059,0.099,0.0058,34310.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-04",24,24,5194,,0.011,0.001,2230.2,0.059,0.105,0.0056,37524.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-05",24,24,4292,,0.01,0.001,1925.8,0.059,0.089,0.0055,32406.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-06",24,24,4422,,0.01,0.001,1990.7,0.059,0.094,0.0055,33496.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-07",24,24,4456,,0.01,0.001,2011,0.059,0.097,0.0057,33842.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-08",12,11.57,2448.28,,0.005,0.001,1065.801,0.059,0.085,0.0154,17932.284,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-09",24,24,4821,,0.011,0.001,2104.1,0.059,0.1,0.0056,35405.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-10",24,24,5246,,0.011,0.001,2241.3,0.059,0.106,0.0056,37711.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-11",24,24,5045,,0.011,0.001,2198.1,0.059,0.101,0.0054,36984.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-12",24,24,5254,,0.011,0.001,2255.2,0.059,0.106,0.0056,37945.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-13",24,24,5374,,0.012,0.001,2287.7,0.059,0.111,0.0058,38492.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-14",24,24,5292,,0.011,0.001,2259.5,0.059,0.112,0.0059,38022.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-15",24,24,5353,,0.011,0.001,2276.3,0.059,0.111,0.0058,38303.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-16",24,24,5294,,0.011,0.001,2264.5,0.059,0.107,0.0056,38103.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-17",24,24,5011,,0.011,0.001,2152.3,0.059,0.105,0.0058,36215.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-18",24,24,5141,,0.011,0.001,2193.1,0.059,0.104,0.0056,36899.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-19",24,24,5165,,0.011,0.001,2194.7,0.059,0.11,0.006,36930.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-20",24,24,5497,,0.012,0.001,2394.6,0.059,0.117,0.0058,40294.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-21",24,24,5794,,0.013,0.001,2493.8,0.059,0.124,0.0059,41963.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-22",24,24,5191,,0.011,0.001,2205,0.059,0.105,0.0057,37106,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-23",24,24,5354,,0.012,0.001,2316.5,0.059,0.11,0.0057,38977.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-24",24,24,5388,,0.012,0.001,2292.3,0.059,0.108,0.0056,38572.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-25",24,24,5449,,0.012,0.001,2353,0.059,0.11,0.0055,39593.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-26",24,24,5248,,0.011,0.001,2256.8,0.059,0.109,0.0058,37972.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-27",24,24,5044,,0.011,0.001,2200.9,0.059,0.11,0.0059,37034.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-28",24,24,5058,,0.011,0.001,2198.5,0.059,0.109,0.0059,36997,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-29",24,24,5163,,0.011,0.001,2258.8,0.059,0.113,0.006,38009.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-30",24,24,4954,,0.011,0.001,2190.8,0.059,0.108,0.0059,36866.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-08-31",24,24,5020,,0.011,0.001,2174.1,0.059,0.109,0.006,36583.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-01",24,24,4928,,0.011,0.001,2172.9,0.059,0.108,0.0059,36562,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-02",24,24,4268,,0.01,0.001,1910.2,0.059,0.089,0.0055,32139.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-03",24,24,5202,,0.011,0.001,2254.3,0.059,0.109,0.0058,37935,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-04",24,24,5379,,0.012,0.001,2308.9,0.059,0.112,0.0058,38848.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-05",24,24,5093,,0.011,0.001,2208.4,0.059,0.106,0.0057,37160.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-06",24,24,5158,,0.011,0.001,2247.3,0.059,0.108,0.0057,37812.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-07",24,24,5312,,0.011,0.001,2247.3,0.059,0.108,0.0057,37816.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-08",24,24,5084,,0.011,0.001,2168.2,0.059,0.101,0.0055,36485.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-09",24,24,4577,,0.01,0.001,2027.4,0.059,0.098,0.0058,34112.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-10",24,24,5105,,0.011,0.001,2199.4,0.059,0.107,0.0058,37009.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-11",24,23.17,4917.37,,0.011,0.001,2130.247,0.059,0.105,0.0063,35843.743,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-14",23,22.37,4727.51,,0.01,0.001,2063.148,0.059,0.158,0.0167,34715.018,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-15",24,24,5456,,0.012,0.001,2367.4,0.059,0.118,0.0059,39833.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-16",24,24,5398,,0.012,0.001,2354.7,0.059,0.116,0.0059,39628.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-17",24,23.72,5219.8,,0.011,0.001,2218.564,0.059,0.109,0.0059,37329.644,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-18",18,16.63,3473.41,,0.008,0.001,1507.044,0.059,0.118,0.0159,25360.379,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-19",12,11.27,2460.86,,0.005,0.001,1066.608,0.059,0.094,0.0236,17946.751,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-20",17,15.34,3360.72,,0.007,0.001,1469.912,0.059,0.107,0.0131,24732.779,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-21",23,22.43,5010.74,,0.011,0.001,2124.725,0.059,0.106,0.0061,35750.024,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-22",8,6.45,1292.05,,0.003,0.001,566.075,0.059,0.071,0.023,9524.618,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-23",9,7.52,1449.28,,0.003,0.001,658.662,0.059,0.052,0.0166,11084.661,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-24",8,6.57,1277.93,,0.003,0.001,571.628,0.059,0.05,0.024,9618.634,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-27",10,9.3,1732.7,,0.004,0.001,764.48,0.0591,0.075,0.0288,12865.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-28",24,24,5052,,0.011,0.001,2175,0.059,0.105,0.0058,36596.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-29",24,24,5123,,0.011,0.001,2230.5,0.059,0.11,0.0058,37532.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-09-30",24,24,5445,,0.012,0.001,2329.9,0.059,0.114,0.0058,39205,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-01",24,24,5532,,0.012,0.001,2355.1,0.059,0.116,0.0059,39628.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-02",24,24,5346,,0.011,0.001,2244,0.059,0.112,0.0059,37763.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-03",24,24,5231,,0.011,0.001,2241.2,0.059,0.108,0.0057,37710.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-04",24,24,5204,,0.011,0.001,2250.9,0.059,0.11,0.0058,37877.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-05",24,24,5445,,0.012,0.001,2343.4,0.059,0.114,0.0058,39427.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-06",24,24,5487,,0.012,0.001,2351.2,0.059,0.114,0.0058,39558.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-07",24,24,5496,,0.012,0.001,2361.2,0.059,0.112,0.0057,39734.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-08",24,24,5113,,0.011,0.001,2235.7,0.059,0.111,0.0059,37614.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-09",24,24,5207,,0.012,0.001,2282.7,0.059,0.109,0.0057,38412.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-10",2,1.48,286.68,,0.001,0.001,132.352,0.059,0.008,0.0085,2227.732,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-11",8,7.05,1192.87,,0.003,0.001,563.074,0.0591,0.083,0.0371,9473.908,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-17",18,15.65,2580.03,,0.006,0.001,1211.283,0.0591,0.295,0.0607,20384.601,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-18",16,15.3,2919.7,,0.007,0.001,1312.01,0.059,0.178,0.0361,22075.73,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-19",24,24,4727,,0.01,0.001,2072,0.059,0.097,0.0055,34869.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-20",24,24,5639,,0.012,0.001,2370.8,0.059,0.115,0.0058,39895,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-21",24,24,5691,,0.012,0.001,2421.1,0.059,0.12,0.0059,40741.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-22",24,24,5648,,0.012,0.001,2403.6,0.059,0.117,0.0058,40446.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-23",24,24,5770,,0.012,0.001,2430.4,0.059,0.118,0.0058,40895.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-24",24,24,5544,,0.012,0.001,2358.1,0.059,0.113,0.0057,39678,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-25",24,24,5527,,0.012,0.001,2346.7,0.059,0.112,0.0057,39485.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-26",24,24,5983,,0.013,0.001,2480.3,0.059,0.123,0.0059,41734.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-27",24,24,6073,,0.013,0.001,2573.8,0.059,0.124,0.0058,43309.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-28",24,24,5909,,0.013,0.001,2516.2,0.059,0.123,0.0058,42340.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-29",24,24,5724,,0.012,0.001,2401.9,0.059,0.119,0.0059,40418.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-30",24,24,5777,,0.012,0.001,2413,0.059,0.121,0.006,40606.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-10-31",24,24,5544,,0.012,0.001,2348.6,0.059,0.117,0.0059,39521.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-01",24,24,5556,,0.012,0.001,2323.2,0.059,0.116,0.006,39091.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-02",24,24,6045,,0.013,0.001,2545.7,0.059,0.127,0.0059,42839.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-03",24,24,6030,,0.013,0.001,2528.8,0.059,0.121,0.0057,42549.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-04",24,24,5893,,0.013,0.001,2484.3,0.059,0.12,0.0058,41795.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-05",24,24,6059,,0.013,0.001,2548.7,0.059,0.125,0.0058,42884.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-06",24,24,5480,,0.012,0.001,2300.6,0.059,0.112,0.0058,38712.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-07",24,24,5051,,0.011,0.001,2206.1,0.059,0.109,0.0059,37116.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-08",24,24,5173,,0.011,0.001,2230.3,0.059,0.11,0.0059,37529,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-09",24,24,5809,,0.013,0.001,2546.8,0.059,0.124,0.0058,42857.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-10",24,24,5886,,0.013,0.001,2539.9,0.059,0.126,0.0059,42742.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-11",24,24,5707,,0.012,0.001,2387.7,0.059,0.113,0.0056,40176.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-12",24,24,5443,,0.012,0.001,2345.5,0.059,0.114,0.0058,39467.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-13",24,24,5456,,0.012,0.001,2304.2,0.059,0.113,0.0058,38773.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-14",24,24,5236,,0.011,0.001,2246.4,0.059,0.113,0.006,37799.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-15",24,24,5331,,0.011,0.001,2242,0.059,0.111,0.0059,37726.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-16",24,24,5585,,0.012,0.001,2367.9,0.059,0.115,0.0058,39847.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-17",24,24,5543,,0.012,0.001,2345.8,0.059,0.113,0.0058,39476.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-18",24,24,5426,,0.011,0.001,2260.8,0.059,0.11,0.0058,38047.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-19",24,24,5517,,0.012,0.001,2333.6,0.059,0.117,0.006,39267.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-20",24,24,5812,,0.012,0.001,2454.7,0.059,0.119,0.0058,41303.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-21",24,24,5640,,0.012,0.001,2390.9,0.059,0.118,0.0059,40228.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-22",24,24,5494,,0.012,0.001,2318.1,0.059,0.114,0.0059,39006.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-23",1,0.55,90.75,,0,0.001,37.51,0.059,0.006,0.019,631.125,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-26",20,19.42,4031.5,,0.009,0.001,1747.006,0.059,0.156,0.0206,29397.834,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-27",24,24,5408,,0.012,0.001,2285.5,0.059,0.112,0.0058,38453.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-28",24,24,5600,,0.012,0.001,2370.6,0.059,0.12,0.006,39890.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-29",24,24,5618,,0.012,0.001,2373.8,0.059,0.115,0.0058,39940.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-11-30",24,24,5646,,0.012,0.001,2386.9,0.059,0.114,0.0057,40164.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-01",24,24,6087,,0.013,0.001,2561.3,0.059,0.126,0.0058,43102.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-02",24,24,5900,,0.013,0.001,2493,0.059,0.122,0.0058,41948.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-03",24,24,6023,,0.013,0.001,2538.8,0.059,0.123,0.0058,42722.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-04",24,24,5942,,0.013,0.001,2516.9,0.059,0.123,0.0058,42349.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-05",24,24,6061,,0.013,0.001,2558.6,0.059,0.127,0.0059,43052.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-06",24,24,5844,,0.012,0.001,2468.9,0.059,0.119,0.0058,41543.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-07",24,24,5959,,0.013,0.001,2521.5,0.059,0.121,0.0057,42432,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-08",24,24,5873,,0.013,0.001,2476.4,0.059,0.119,0.0058,41669.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-09",24,24,5731,,0.012,0.001,2425.6,0.059,0.12,0.0059,40813.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-10",24,24,6000,,0.013,0.001,2529.3,0.059,0.123,0.0058,42561.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-11",24,24,5935,,0.013,0.001,2504.1,0.059,0.126,0.006,42135.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-12",24,24,6124,,0.013,0.001,2588.1,0.059,0.123,0.0057,43550.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-13",24,24,6163,,0.013,0.001,2596,0.059,0.128,0.0059,43681.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-14",24,24,6206,,0.013,0.001,2624.8,0.059,0.126,0.0057,44161.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-15",24,24,6186,,0.013,0.001,2615.7,0.059,0.122,0.0056,44013,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-16",24,24,6349,,0.014,0.001,2689.8,0.059,0.128,0.0057,45262.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-17",24,24,5563,,0.012,0.001,2351.4,0.059,0.117,0.0059,39565.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-18",24,24,5628,,0.012,0.001,2403.3,0.059,0.113,0.0056,40437.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-19",24,24,5846,,0.012,0.001,2471.2,0.059,0.12,0.0058,41586.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-20",24,24,5576,,0.012,0.001,2360.1,0.059,0.114,0.0058,39709.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-21",24,24,5821,,0.012,0.001,2464.3,0.059,0.117,0.0056,41463.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-22",24,24,5801,,0.012,0.001,2456.2,0.059,0.122,0.0059,41329.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-23",24,24,5956,,0.013,0.001,2533.5,0.059,0.118,0.0055,42628.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-24",24,24,6092,,0.013,0.001,2561.1,0.059,0.126,0.0059,43091.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-25",24,24,5811,,0.012,0.001,2465,0.059,0.121,0.0058,41475.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-26",24,24,5536,,0.012,0.001,2337.3,0.059,0.115,0.0059,39331.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-27",24,24,5858,,0.013,0.001,2478.2,0.059,0.121,0.0058,41704.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-28",24,24,6233,,0.013,0.001,2633.2,0.059,0.128,0.0058,44306.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-29",24,24,6002,,0.013,0.001,2544.3,0.059,0.127,0.0059,42812.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-30",24,24,5817,,0.012,0.001,2468,0.059,0.119,0.0058,41526.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT1",,"2020-12-31",24,24,5727,,0.012,0.001,2435.2,0.059,0.12,0.0059,40976.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-01",24,24,5018,,0.011,0.001,2171,0.059,0.108,0.0059,36530.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-02",24,24,5634,,0.012,0.001,2416.9,0.059,0.118,0.0058,40668,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-03",24,24,5302,,0.012,0.001,2285.3,0.059,0.112,0.0058,38454.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-04",24,23.57,5203.65,,0.011,0.001,2234.112,0.059,0.117,0.0068,37591.691,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-05",6,5.28,779.8,,0.002,0.001,409.928,0.059,0.157,0.0995,6897.544,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-06",24,24,5744,,0.013,0.001,2486.8,0.059,0.124,0.0059,41846.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-07",24,24,5952,,0.013,0.001,2539.7,0.059,0.115,0.0054,42738.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-08",24,24,5574,,0.012,0.001,2380,0.059,0.113,0.0056,40047.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-09",24,24,5946,,0.013,0.001,2564.5,0.059,0.118,0.0055,43150.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-10",24,24,6392,,0.014,0.001,2737.4,0.059,0.134,0.0058,46064.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-11",24,24,5304,,0.012,0.001,2285.7,0.059,0.111,0.0058,38461.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-12",24,24,5197,,0.011,0.001,2245.2,0.059,0.111,0.0059,37780,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-13",24,24,5599,,0.012,0.001,2412.4,0.059,0.117,0.0058,40594,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-14",24,24,5579,,0.012,0.001,2402.9,0.059,0.114,0.0056,40434.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-15",24,24,5860,,0.013,0.001,2510,0.059,0.12,0.0056,42234.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-16",24,24,5597,,0.012,0.001,2403.8,0.059,0.114,0.0056,40447.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-17",24,24,5517,,0.012,0.001,2380.1,0.059,0.12,0.006,40054.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-18",24,24,5263,,0.011,0.001,2277.2,0.059,0.113,0.0059,38316.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-19",24,24,5395,,0.012,0.001,2323.3,0.059,0.105,0.0053,39091.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-20",24,24,5527,,0.012,0.001,2369.2,0.059,0.114,0.0057,39868.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-21",24,24,5179,,0.011,0.001,2238.4,0.059,0.112,0.006,37668.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-22",24,24,5413,,0.012,0.001,2325.8,0.059,0.115,0.0059,39136.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-23",24,24,5650,,0.012,0.001,2422.4,0.059,0.117,0.0057,40760,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-24",24,24,5430,,0.012,0.001,2337.9,0.059,0.114,0.0058,39340.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-25",24,24,5095,,0.011,0.001,2207.5,0.059,0.101,0.0054,37144.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-26",24,24,4745,,0.01,0.001,2074.2,0.059,0.1,0.0057,34904.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-27",24,24,5179,,0.011,0.001,2245,0.059,0.111,0.0059,37778.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-28",24,24,5268,,0.012,0.001,2279.5,0.059,0.108,0.0057,38362.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-29",24,24,5516,,0.012,0.001,2377,0.059,0.114,0.0057,39995.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-30",24,24,5371,,0.012,0.001,2315,0.059,0.111,0.0057,38957.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-01-31",24,24,5251,,0.011,0.001,2262.6,0.059,0.113,0.0059,38073.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-01",24,24,5244,,0.011,0.001,2263.1,0.059,0.107,0.0056,38082.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-02",24,24,4976,,0.011,0.001,2153.5,0.059,0.107,0.0059,36239.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-03",24,24,5427,,0.012,0.001,2332.6,0.059,0.115,0.0059,39249.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-04",24,24,5838,,0.013,0.001,2499.9,0.059,0.12,0.0057,42065.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-05",24,24,5800,,0.013,0.001,2478.8,0.059,0.119,0.0057,41712.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-06",24,24,5404,,0.012,0.001,2333.7,0.059,0.11,0.0056,39265.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-07",24,24,5504,,0.012,0.001,2362,0.059,0.114,0.0058,39751.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-08",24,23.97,5125.17,,0.011,0.001,2215.282,0.059,0.115,0.0063,37277.784,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-10",23,22.9,4468.9,,0.01,0.001,2005.37,0.059,0.199,0.022,33740.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-11",24,24,5383,,0.012,0.001,2315.8,0.059,0.116,0.006,38969.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-12",24,24,5905,,0.013,0.001,2526.2,0.059,0.122,0.0058,42505.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-13",24,24,5835,,0.013,0.001,2492.3,0.059,0.121,0.0058,41938.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-14",24,24,5474,,0.012,0.001,2352.5,0.059,0.117,0.0059,39582.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-15",24,24,5368,,0.012,0.001,2307.9,0.059,0.115,0.0059,38836.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-16",24,24,5037,,0.011,0.001,2181.3,0.059,0.109,0.006,36705.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-17",24,24,5296,,0.011,0.001,2272.4,0.059,0.113,0.0059,38240,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-18",24,24,5464,,0.012,0.001,2348.1,0.059,0.119,0.006,39514.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-19",24,24,5482,,0.012,0.001,2355.6,0.059,0.117,0.0059,39634.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-20",24,24,5546,,0.012,0.001,2381.9,0.059,0.117,0.0059,40081.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-21",24,24,5411,,0.012,0.001,2322.5,0.059,0.115,0.0059,39082.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-22",24,23.88,4956.52,,0.011,0.001,2133.776,0.059,0.109,0.0063,35907.852,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-24",24,23.4,4861.2,,0.011,0.001,2165.82,0.059,0.228,0.0273,36445.84,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-25",24,24,5556,,0.012,0.001,2384.9,0.059,0.117,0.0058,40130.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-26",24,24,5563,,0.012,0.001,2388.3,0.059,0.119,0.0059,40188.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-27",24,24,5582,,0.012,0.001,2391.6,0.059,0.118,0.0059,40242.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-28",24,23.87,5185.5,,0.011,0.001,2235.519,0.059,0.113,0.0062,37613.575,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-01",1,0.13,0,,0,0.001,1.781,0.059,0.001,0.087,29.991,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-02",24,24,4944,,0.011,0.001,2202.7,0.059,0.223,0.0218,37061.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-03",24,24,5468,,0.012,0.001,2349.6,0.059,0.118,0.006,39537.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-04",24,24,5497,,0.012,0.001,2355.8,0.059,0.118,0.006,39638.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-05",24,24,5481,,0.012,0.001,2368.7,0.059,0.113,0.0056,39859.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-06",24,24,5792,,0.012,0.001,2475.8,0.059,0.12,0.0058,41661.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-07",24,24,5770,,0.012,0.001,2467.7,0.059,0.121,0.0058,41524.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-08",24,24,5793,,0.013,0.001,2492.2,0.059,0.121,0.0058,41935.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-09",24,24,5882,,0.013,0.001,2516.9,0.059,0.123,0.0058,42353,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-10",24,24,5779,,0.012,0.001,2473.4,0.059,0.121,0.0058,41618.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-11",24,24,5647,,0.012,0.001,2421.3,0.059,0.12,0.0059,40743.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-12",24,24,5792,,0.012,0.001,2472.8,0.059,0.12,0.0058,41614.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-13",24,24,5640,,0.012,0.001,2415.6,0.059,0.117,0.0058,40648.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-14",24,24,5471,,0.012,0.001,2345.3,0.059,0.118,0.006,39462.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-15",24,24,5549,,0.012,0.001,2386.1,0.059,0.117,0.0059,40150.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-16",24,24,6160,,0.013,0.001,2645.4,0.059,0.126,0.0057,44516.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-17",24,24,5904,,0.013,0.001,2538.4,0.059,0.125,0.0059,42711.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-18",24,24,5725,,0.012,0.001,2458.2,0.059,0.118,0.0058,41358.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-19",24,24,5715,,0.012,0.001,2461.5,0.059,0.12,0.0058,41422.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-20",24,24,5916,,0.013,0.001,2539.2,0.059,0.125,0.0058,42728.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-21",24,24,5733,,0.013,0.001,2477.2,0.059,0.12,0.0058,41683,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-22",24,24,5789,,0.013,0.001,2481.3,0.059,0.123,0.0059,41755.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-23",24,24,5538,,0.012,0.001,2374.3,0.059,0.116,0.0058,39951.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-24",24,24,5803,,0.013,0.001,2482.5,0.059,0.123,0.0059,41771.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-25",24,24,5695,,0.012,0.001,2434,0.059,0.117,0.0058,40956.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-26",9,8.18,1796.34,,0.004,0.001,776.916,0.0591,0.045,0.02,13074.354,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-28",11,10.65,1871.75,,0.005,0.001,894.44,0.059,0.225,0.0626,15050.81,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-29",2,1.48,287.16,,0.001,0.001,132.048,0.059,0.008,0.0085,2222.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-30",6,5.55,823.15,,0.002,0.001,416.965,0.059,0.147,0.0875,7017.31,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-03-31",24,23.02,4942,,0.011,0.001,2143.968,0.059,0.116,0.0073,36075.254,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-27",4,2.44,67.88,,0,0.001,85.2,0.0593,0.16,0.172,1433.148,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-28",15,14.45,2604.75,,0.006,0.001,1212.38,0.059,0.186,0.041,20398.885,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-29",23,22.13,4435.56,,0.01,0.001,1925.537,0.059,0.065,0.0098,32400.505,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-07",15,13.71,2252.75,,0.005,0.001,1078.52,0.059,0.24,0.0589,18149.218,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-08",12,10.6,1842.5,,0.004,0.001,861.584,0.0591,0.125,0.0396,14493.836,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-11",8,7.45,1035.75,,0.003,0.001,541.695,0.059,0.195,0.0846,9113.795,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-12",2,1.27,162.33,,0,0.001,80.433,0.059,0.007,0.025,1353.387,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-17",5,4.83,263.62,,0.001,0.001,211.69,0.059,0.208,0.1418,3560.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-18",24,24,3833,,0.009,0.001,1833.6,0.059,0.087,0.0056,30855.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-19",20,18.31,2728.52,,0.007,0.001,1334.213,0.0591,0.162,0.0335,22452.094,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-20",23,21.53,2958.34,,0.007,0.001,1466.899,0.059,0.115,0.016,24684.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-21",19,18.05,3236.8,,0.008,0.001,1501.695,0.059,0.149,0.0207,25269.37,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-22",20,18.42,2779.8,,0.007,0.001,1351.81,0.059,0.168,0.0322,22746.902,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-23",20,18.74,3013.62,,0.007,0.001,1440.908,0.059,0.136,0.0218,24249.316,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-24",21,19.48,3283.54,,0.008,0.001,1527.368,0.059,0.121,0.0152,25701.526,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-25",24,24,4527,,0.01,0.001,2009.8,0.059,0.097,0.0057,33814.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-26",24,24,5119,,0.011,0.001,2237.1,0.059,0.111,0.0059,37645,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-27",24,24,5112,,0.011,0.001,2236.5,0.059,0.11,0.0058,37636,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-28",24,23.82,5017.02,,0.011,0.001,2176.174,0.059,0.114,0.0064,36616.618,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-29",9,7.37,1461.15,,0.003,0.0009,654.991,0.0591,0.066,0.016,11020.369,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-01",13,12.3,2732.4,,0.006,0.001,1207.38,0.059,0.127,0.0301,20315.65,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-02",24,24,5517,,0.012,0.001,2383.2,0.059,0.119,0.006,40105.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-03",24,24,5754,,0.013,0.001,2492.7,0.059,0.123,0.0059,41942.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-04",24,24,5627,,0.012,0.001,2444.8,0.059,0.118,0.0058,41135.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-05",24,23.47,5050.63,,0.011,0.001,2182.09,0.059,0.106,0.006,36719.731,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-08",10,9.33,2029.27,,0.005,0.001,905.035,0.059,0.121,0.042,15227.747,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-09",18,17.11,3887.67,,0.009,0.001,1693.728,0.059,0.108,0.0109,28502.232,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-10",24,24,5510,,0.012,0.001,2379.8,0.059,0.113,0.0057,40044.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-11",24,24,5557,,0.012,0.001,2408,0.059,0.121,0.006,40518,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-12",7,6.43,1333.44,,0.003,0.001,573.801,0.059,0.031,0.007,9654.773,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-15",10,8.75,1742.93,,0.004,0.001,777.594,0.059,0.105,0.0325,13082.083,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-17",10,9.12,1797.12,,0.004,0.001,800.568,0.0591,0.096,0.0298,13469.208,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-18",24,24,5285,,0.011,0.001,2271.3,0.059,0.114,0.006,38217.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-19",24,23.22,5063.76,,0.011,0.001,2188.694,0.059,0.111,0.0064,36831.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-21",10,9.22,1938.86,,0.004,0.001,855.042,0.0591,0.062,0.0217,14387.592,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-22",24,23.97,5581.42,,0.012,0.001,2409.682,0.059,0.122,0.006,40544.614,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-23",9,8.9,2124,,0.005,0.001,928.93,0.059,0.073,0.0141,15631.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-24",24,24,5362,,0.012,0.001,2308.7,0.059,0.115,0.0059,38853.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-25",24,24,5427,,0.012,0.001,2335.7,0.059,0.113,0.0058,39301.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-26",24,23.8,5146.6,,0.011,0.001,2230.1,0.059,0.111,0.006,37521.78,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-27",15,14.35,2970.2,,0.007,0.001,1343.645,0.0591,0.16,0.0322,22609.555,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-28",9,8.25,1375.35,,0.003,0.001,661.535,0.0591,0.111,0.0463,11129.81,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-29",20,18.68,3801.04,,0.009,0.001,1734.414,0.0591,0.117,0.0136,29185.518,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-06-30",24,23.33,5003.71,,0.011,0.001,2164.059,0.059,0.107,0.0061,36412.599,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-05",15,14.93,2601.3,,0.006,0.001,1196.308,0.059,0.199,0.0422,20128.851,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-06",24,24,5161,,0.011,0.001,2235.8,0.059,0.109,0.0058,37618.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-07",24,24,4917,,0.011,0.001,2173.8,0.059,0.105,0.0058,36580.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-08",24,24,4606,,0.01,0.001,2070.8,0.059,0.099,0.0056,34843.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-09",24,24,4769,,0.011,0.001,2124.2,0.059,0.104,0.0058,35743.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-10",24,24,5248,,0.012,0.001,2287.8,0.059,0.114,0.0059,38498.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-11",24,24,5357,,0.012,0.001,2337.7,0.059,0.116,0.0059,39331.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-12",24,24,5189,,0.011,0.001,2241.2,0.059,0.112,0.006,37707.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-13",24,24,5245,,0.011,0.001,2264.9,0.059,0.114,0.006,38114.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-14",24,24,5294,,0.011,0.001,2263.9,0.059,0.113,0.006,38094.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-15",24,24,4581,,0.01,0.001,2061.9,0.059,0.098,0.0055,34694.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-16",24,24,5240,,0.011,0.001,2228.1,0.059,0.112,0.006,37492.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-17",24,24,4679,,0.01,0.001,2077.1,0.059,0.102,0.0058,34946.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-18",24,24,5004,,0.011,0.001,2206.7,0.059,0.111,0.006,37130.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-19",24,24,4478,,0.01,0.001,2013.6,0.059,0.097,0.0057,33880,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-20",24,24,5283,,0.011,0.001,2267.6,0.059,0.113,0.0059,38157.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-21",24,24,5451,,0.012,0.001,2324.4,0.059,0.116,0.0059,39110,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-22",24,24,4442,,0.01,0.001,1990.7,0.059,0.094,0.0055,33491.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-23",24,24,4800,,0.011,0.001,2096,0.059,0.103,0.0058,35266.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-24",24,24,4299,,0.01,0.001,1982.6,0.059,0.098,0.0058,33363.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-25",24,24,5126,,0.011,0.001,2182.8,0.059,0.11,0.006,36724.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-26",24,24,5041,,0.011,0.001,2213.4,0.059,0.109,0.0058,37248.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-27",24,24,5469,,0.012,0.001,2361,0.059,0.119,0.006,39730,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-28",24,24,5726,,0.012,0.001,2457.1,0.059,0.122,0.0059,41347.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-29",24,24,5702,,0.012,0.001,2455.9,0.059,0.121,0.0059,41325.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-30",24,24,5563,,0.012,0.001,2412.1,0.059,0.118,0.0058,40589.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-07-31",24,24,5711,,0.013,0.001,2495.4,0.059,0.122,0.0058,41985.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-01",24,24,5416,,0.012,0.001,2394.5,0.059,0.12,0.0059,40289.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-02",19,17.95,3770.9,,0.008,0.001,1668.863,0.059,0.109,0.0136,28083.613,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-03",24,24,4712,,0.01,0.001,2077.5,0.059,0.104,0.0059,34955.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-04",24,24,5248,,0.012,0.001,2281.7,0.059,0.113,0.0059,38393,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-05",24,23.95,4303.85,,0.01,0.001,1953.085,0.059,0.095,0.0058,32860.495,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-06",8,7.45,1500,,0.003,0.001,682.235,0.059,0.061,0.016,11479.755,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-07",11,10.88,2412.64,,0.005,0.001,1072.924,0.059,0.076,0.0132,18054.408,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-08",24,24,4473,,0.01,0.001,2033.4,0.059,0.101,0.0059,34215.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-09",24,24,4846,,0.011,0.001,2142.1,0.059,0.105,0.0058,36046.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-10",24,24,5260,,0.012,0.001,2290.3,0.059,0.116,0.006,38535.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-11",24,24,5058,,0.011,0.001,2235,0.059,0.112,0.006,37611.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-12",24,24,5327,,0.012,0.001,2303.7,0.059,0.116,0.006,38760.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-13",24,24,5420,,0.012,0.001,2338.3,0.059,0.114,0.0058,39345.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-14",24,24,5342,,0.012,0.001,2308.8,0.059,0.117,0.006,38848.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-15",24,24,5409,,0.012,0.001,2328.9,0.059,0.115,0.0059,39189.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-16",24,24,5342,,0.012,0.001,2314.7,0.059,0.114,0.0059,38952.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-17",24,24,5067,,0.011,0.001,2195.3,0.059,0.109,0.0059,36941.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-18",24,24,5204,,0.011,0.001,2267.4,0.059,0.114,0.006,38153.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-19",24,24,5246,,0.011,0.001,2229.6,0.059,0.109,0.0058,37515.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-20",24,24,5623,,0.013,0.001,2483.2,0.059,0.123,0.0059,41781.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-21",24,24,5899,,0.013,0.001,2555.9,0.059,0.124,0.0058,43012.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-22",24,24,5319,,0.012,0.001,2304.1,0.059,0.116,0.006,38763.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-23",24,24,5445,,0.012,0.001,2370.3,0.059,0.119,0.006,39885.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-24",24,24,5464,,0.012,0.001,2353.1,0.059,0.118,0.006,39594.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-25",24,24,5541,,0.012,0.001,2453.2,0.059,0.121,0.0059,41278,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-26",24,24,5321,,0.012,0.001,2332.8,0.059,0.116,0.0059,39253.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-27",24,24,5135,,0.011,0.001,2251.4,0.059,0.112,0.0059,37881.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-28",24,24,5140,,0.011,0.001,2248.6,0.059,0.111,0.0059,37831.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-29",24,24,5252,,0.012,0.001,2300.1,0.059,0.115,0.006,38707.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-30",24,24,5101,,0.011,0.001,2235.2,0.059,0.11,0.0059,37608.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-08-31",24,24,5119,,0.012,0.001,2278.3,0.059,0.113,0.0059,38331.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-01",24,24,4999,,0.011,0.001,2207.8,0.059,0.107,0.0058,37146.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-02",24,24,4306,,0.01,0.001,1950.6,0.059,0.094,0.0058,32822.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-03",24,24,5272,,0.012,0.001,2305.2,0.059,0.115,0.0059,38785.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-04",24,24,5450,,0.012,0.001,2366.4,0.059,0.116,0.0058,39815.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-05",24,24,5173,,0.011,0.001,2259.3,0.059,0.111,0.0058,38019,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-06",24,24,5297,,0.012,0.001,2309.3,0.059,0.114,0.0059,38859.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-07",24,24,5440,,0.012,0.001,2401.3,0.059,0.117,0.0058,40406,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-08",24,24,5193,,0.012,0.001,2320.9,0.059,0.11,0.0056,39056.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-09",24,24,4671,,0.011,0.001,2094.3,0.059,0.103,0.0058,35234.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-10",24,24,5189,,0.012,0.001,2297.7,0.059,0.111,0.0058,38662,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-11",24,23.62,5090.1,,0.011,0.001,2233.102,0.059,0.117,0.0065,37578.222,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-12",6,5.28,502.08,,0.001,0.001,283.396,0.059,0.11,0.0897,4767.912,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-13",14,12.59,1931.89,,0.005,0.001,929.763,0.0591,0.146,0.0466,15645.462,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-14",24,24,5237,,0.012,0.001,2286,0.059,0.11,0.0058,38466.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-15",24,24,5486,,0.012,0.001,2419.9,0.059,0.12,0.0059,40720.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-16",24,24,5429,,0.012,0.001,2416.8,0.059,0.12,0.0059,40667.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-17",24,24,5304,,0.012,0.001,2315.9,0.059,0.113,0.0058,38971.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-18",23,20.61,4204.28,,0.009,0.001,1845.894,0.059,0.146,0.018,31054.625,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-19",20,19.57,3752.55,,0.009,0.001,1705.349,0.0591,0.139,0.017,28694.469,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-20",20,19.15,4115.37,,0.009,0.001,1824.656,0.0591,0.151,0.0191,30706.581,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-21",23,22.9,5171.9,,0.011,0.001,2222.39,0.059,0.111,0.006,37397.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-22",12,10.94,2004,,0.005,0.001,927.554,0.059,0.129,0.0296,15608.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-23",13,12.06,2123.59,,0.005,0.001,984.33,0.0591,0.125,0.0333,16559.918,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-24",13,11.92,2234.08,,0.005,0.001,1028.286,0.0592,0.126,0.0352,17301.94,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-27",14,13.75,2289,,0.005,0.001,1065.05,0.0591,0.175,0.0417,17919.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-28",24,24,5155,,0.011,0.001,2256.4,0.059,0.112,0.0059,37965.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-29",24,24,5314,,0.012,0.001,2302.9,0.059,0.114,0.0059,38750.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-09-30",24,24,5625,,0.012,0.001,2424.6,0.059,0.119,0.0058,40797.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-01",24,24,5725,,0.012,0.001,2465.3,0.059,0.12,0.0058,41485.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-02",24,24,5529,,0.012,0.001,2349.9,0.059,0.118,0.006,39539.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-03",24,24,5421,,0.012,0.001,2311,0.059,0.112,0.0058,38888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-04",24,24,5377,,0.012,0.001,2326.7,0.059,0.116,0.0059,39151.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-05",24,24,5634,,0.012,0.001,2425.1,0.059,0.117,0.0058,40810.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-06",24,24,5687,,0.012,0.001,2475.1,0.059,0.121,0.0058,41650.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-07",24,24,5676,,0.012,0.001,2460.6,0.059,0.119,0.0058,41402.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-08",24,24,5261,,0.012,0.001,2296.4,0.059,0.113,0.0059,38640.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-09",24,24,5390,,0.012,0.001,2317.9,0.059,0.116,0.006,39003.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-10",2,1.92,362.6,,0.001,0.001,172.996,0.059,0.017,0.0125,2910.36,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-11",20,19.27,2863.24,,0.007,0.001,1419.821,0.0591,0.194,0.0331,23892.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-17",8,7.68,1453.26,,0.003,0.001,661.774,0.059,0.064,0.0193,11133.232,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-18",11,10.82,2334.12,,0.005,0.001,1051.112,0.059,0.073,0.0116,17688.618,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-19",13,12.12,1771.76,,0.004,0.001,855.502,0.0591,0.086,0.0235,14393.597,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-20",24,24,5662,,0.012,0.001,2429.5,0.059,0.121,0.0059,40881.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-21",24,24,5804,,0.013,0.001,2520.4,0.059,0.125,0.0059,42407.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-22",24,24,5684,,0.012,0.001,2452.3,0.059,0.12,0.0058,41266.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-23",24,24,5786,,0.013,0.001,2494,0.059,0.122,0.0058,41964.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-24",24,24,5536,,0.012,0.001,2404.6,0.059,0.119,0.0059,40463.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-25",24,24,5530,,0.012,0.001,2408.5,0.059,0.117,0.0058,40524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-26",24,24,5996,,0.013,0.001,2580.5,0.059,0.128,0.0059,43421,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-27",24,24,6086,,0.013,0.001,2652.1,0.059,0.131,0.0059,44625.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-28",24,24,5935,,0.013,0.001,2631.7,0.059,0.126,0.0057,44284.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-29",24,24,5721,,0.012,0.001,2450.3,0.059,0.12,0.0058,41230,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-30",24,24,5777,,0.012,0.001,2464.5,0.059,0.121,0.0058,41473,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-10-31",24,24,5538,,0.012,0.001,2378.3,0.059,0.117,0.0058,40026.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-01",24,24,5561,,0.012,0.001,2393.4,0.059,0.121,0.006,40272.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-02",24,24,6077,,0.013,0.001,2596.9,0.059,0.127,0.0058,43700.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-03",24,24,6074,,0.013,0.001,2619.9,0.059,0.128,0.0058,44088.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-04",24,24,5938,,0.013,0.001,2568.8,0.059,0.124,0.0058,43225.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-05",24,24,6079,,0.013,0.001,2600.4,0.059,0.127,0.0058,43754.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-06",24,24,5489,,0.012,0.001,2353.2,0.059,0.117,0.0059,39601.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-07",24,24,5064,,0.011,0.001,2256.4,0.059,0.112,0.0059,37967,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-08",24,24,5173,,0.011,0.001,2273,0.059,0.112,0.0058,38246.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-09",24,24,5819,,0.013,0.001,2606.7,0.059,0.127,0.0058,43862,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-10",24,24,5920,,0.013,0.001,2667.4,0.059,0.133,0.0059,44882.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-11",24,24,5719,,0.012,0.001,2435.1,0.059,0.117,0.0057,40971.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-12",24,24,5481,,0.012,0.001,2419.1,0.059,0.116,0.0057,40709.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-13",24,24,5476,,0.012,0.001,2361.6,0.059,0.117,0.0059,39736.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-14",24,24,5252,,0.012,0.001,2280.9,0.059,0.114,0.006,38382.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-15",24,24,5366,,0.011,0.001,2275.9,0.059,0.114,0.006,38295.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-16",24,24,5651,,0.012,0.001,2428.3,0.059,0.121,0.0059,40859.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-17",24,24,5608,,0.012,0.001,2390,0.059,0.112,0.0056,40219.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-18",24,24,5473,,0.012,0.001,2308.2,0.059,0.114,0.0059,38837.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-19",24,24,5576,,0.012,0.001,2380.4,0.059,0.118,0.0059,40056.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-20",24,24,5872,,0.013,0.001,2516.3,0.059,0.124,0.0058,42343.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-21",24,24,5679,,0.012,0.001,2444.6,0.059,0.12,0.0058,41134.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-22",24,24,5521,,0.012,0.001,2365.6,0.059,0.116,0.0058,39804.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-23",1,0.17,7.14,,0,0.001,5.95,0.059,0.001,0.029,100.198,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-25",2,1.22,15.3,,0,0.001,39.022,0.059,0.059,0.183,656.596,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-26",24,24,4696,,0.011,0.001,2119.2,0.059,0.262,0.0267,35660.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-27",24,24,5450,,0.012,0.001,2331.9,0.059,0.114,0.0058,39240.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-28",24,24,5610,,0.012,0.001,2400,0.059,0.121,0.006,40387.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-29",24,24,5630,,0.012,0.001,2410.8,0.059,0.118,0.0058,40563.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-11-30",24,24,5645,,0.012,0.001,2416.4,0.059,0.116,0.0057,40660.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-01",24,24,6106,,0.013,0.001,2610.2,0.059,0.125,0.0057,43920.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-02",24,24,5905,,0.013,0.001,2531.6,0.059,0.125,0.0059,42600.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-03",24,24,6122,,0.013,0.001,2616.9,0.059,0.125,0.0057,44031.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-04",24,24,5992,,0.013,0.001,2569.7,0.059,0.123,0.0057,43234.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-05",24,24,6115,,0.013,0.001,2625.6,0.059,0.128,0.0058,44176.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-06",24,24,5884,,0.013,0.001,2520.6,0.059,0.122,0.0058,42414.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-07",24,24,5978,,0.013,0.001,2570.3,0.059,0.123,0.0057,43252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-08",24,24,5884,,0.013,0.001,2517,0.059,0.12,0.0057,42353.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-09",24,24,5758,,0.012,0.001,2471.8,0.059,0.122,0.0059,41593,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-10",24,24,6001,,0.013,0.001,2570,0.059,0.126,0.0058,43247.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-11",24,24,5955,,0.013,0.001,2553.2,0.059,0.129,0.006,42964.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-12",24,24,6172,,0.013,0.001,2647.2,0.059,0.126,0.0057,44539.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-13",24,24,6203,,0.013,0.001,2648,0.059,0.13,0.0058,44559.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-14",24,24,6232,,0.013,0.001,2669.3,0.059,0.13,0.0058,44916.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-15",24,24,6230,,0.013,0.001,2670.1,0.059,0.125,0.0056,44925,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-16",24,24,6391,,0.014,0.001,2744.7,0.059,0.134,0.0058,46185.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-17",24,24,5603,,0.012,0.001,2402.6,0.059,0.119,0.0059,40426.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-18",24,24,5684,,0.012,0.001,2469.3,0.059,0.116,0.0056,41550.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-19",24,24,5899,,0.013,0.001,2529.2,0.059,0.12,0.0057,42557.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-20",24,24,5633,,0.012,0.001,2413.8,0.059,0.118,0.0058,40619.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-21",24,24,5859,,0.013,0.001,2513.2,0.059,0.122,0.0058,42286.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-22",24,24,5847,,0.013,0.001,2510.8,0.059,0.122,0.0058,42250,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-23",24,24,5997,,0.013,0.001,2580.5,0.059,0.124,0.0057,43423.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-24",24,24,6147,,0.013,0.001,2612.7,0.059,0.127,0.0058,43960.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-25",24,24,5848,,0.013,0.001,2509.8,0.059,0.125,0.0059,42231.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-26",24,24,5538,,0.012,0.001,2370.8,0.059,0.118,0.0059,39893.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-27",24,24,5889,,0.013,0.001,2529.4,0.059,0.124,0.0058,42560.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-28",24,24,6255,,0.014,0.001,2683.5,0.059,0.13,0.0058,45153.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-29",24,24,6029,,0.013,0.001,2599.6,0.059,0.126,0.0058,43740.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-30",24,24,5847,,0.013,0.001,2516.1,0.059,0.12,0.0057,42336.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Gateway Generating Station",56476,"GT2",,"2020-12-31",24,24,5732,,0.012,0.001,2464.4,0.059,0.118,0.0057,41468.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-01",3,2.43,399.71,,0.001,0.001,271.439,0.059,0.012,0.008,4566.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-02",17,16.28,2487.68,,0.009,0.001,1717.744,0.059,0.116,0.0243,28906.612,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-03",24,23.92,4846.72,,0.014,0.001,2687.48,0.059,0.081,0.0035,45219.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-04",1,0.02,0,,0,0,0,0,0,0,0.004,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-06",17,16.13,3982.13,,0.008,0.001,1661.338,0.059,0.126,0.0218,27956.464,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-07",23,22.48,6153.36,,0.013,0.001,2522.048,0.059,0.075,0.0037,42438.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-09",22,21.28,5284.8,,0.011,0.001,2209.056,0.059,0.122,0.0186,37174.536,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-10",24,24,6821,,0.014,0.001,2798.4,0.059,0.079,0.0032,47089.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-11",9,8.52,2468.68,,0.005,0.001,1008.484,0.059,0.038,0.0051,16969.216,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-13",21,20.2,4827.4,,0.01,0.001,2037.7,0.059,0.154,0.0262,34287.96,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-14",24,24,6719,,0.014,0.001,2753.8,0.059,0.09,0.0039,46340.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-15",24,24,6844,,0.014,0.001,2812.8,0.059,0.095,0.004,47331.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-16",24,24,6772,,0.014,0.001,2775.4,0.059,0.094,0.004,46700.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-17",24,24,6820,,0.014,0.001,2791.8,0.059,0.096,0.0041,46978.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-18",24,24,6720,,0.014,0.001,2753.5,0.059,0.093,0.004,46335.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-19",24,24,6159,,0.013,0.001,2532.1,0.059,0.085,0.004,42607.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-20",24,24,7299,,0.015,0.001,2995.3,0.059,0.102,0.004,50395.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-21",24,24,6766,,0.014,0.001,2766.7,0.059,0.093,0.004,46553.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-22",24,24,5952,,0.012,0.001,2457.9,0.059,0.083,0.004,41355.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-23",24,24,6650,,0.014,0.001,2731.7,0.059,0.092,0.004,45965,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-24",24,23.5,5911,,0.012,0.001,2440.65,0.059,0.084,0.0043,41070.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-28",20,19.14,4490.5,,0.01,0.001,1883.108,0.0591,0.144,0.0211,31685.616,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-30",22,21.67,5211.73,,0.011,0.001,2171.191,0.059,0.143,0.0185,36534.767,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-01-31",20,18.87,4387.17,,0.009,0.001,1838.173,0.059,0.093,0.0082,30931.092,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-03",21,20.13,4934.13,,0.01,0.001,2076.952,0.059,0.16,0.0193,34951.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-04",24,24,6958,,0.014,0.001,2849.2,0.059,0.098,0.0041,47942.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-05",24,24,6808,,0.014,0.001,2791.8,0.059,0.101,0.0043,46975.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-06",24,24,6651,,0.014,0.001,2719.9,0.059,0.093,0.004,45767.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-07",24,23.48,6111.32,,0.013,0.001,2510.576,0.059,0.087,0.0043,42244.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-10",21,20.7,4929.7,,0.01,0.001,2070.05,0.059,0.196,0.0276,34828.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-11",24,24,5925,,0.012,0.001,2448.6,0.059,0.081,0.0039,41202.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-12",24,24,6012,,0.012,0.001,2473.1,0.059,0.082,0.0039,41611.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-13",24,24,6723,,0.014,0.001,2751.1,0.059,0.093,0.004,46293.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-14",1,0.97,223.1,,0,0.001,90.889,0.059,0.006,0.008,1529.69,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-17",9,8.95,2159.75,,0.005,0.001,918.985,0.059,0.133,0.0434,15463.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-18",24,24,6976,,0.014,0.001,2870.1,0.059,0.096,0.004,48299.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-19",24,24,7146,,0.015,0.001,2909.4,0.059,0.1,0.0041,48952.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-20",24,24,7103,,0.014,0.001,2870.2,0.059,0.099,0.0041,48297.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-21",24,23.48,5903.76,,0.012,0.001,2394.664,0.059,0.083,0.0043,40298.284,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-25",10,9.67,2367.73,,0.005,0.001,997.757,0.059,0.146,0.0505,16789.152,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-26",9,8.47,2453.72,,0.005,0.001,989.517,0.059,0.036,0.0049,16648.826,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-27",22,21.55,5488.25,,0.011,0.001,2245.075,0.059,0.175,0.0206,37776.295,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-28",24,23.52,5771.04,,0.012,0.001,2352.04,0.059,0.084,0.0043,39577.192,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-03",9,8.63,2156.97,,0.005,0.001,914.48,0.059,0.138,0.056,15389.399,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-04",24,24,6437,,0.013,0.001,2619.3,0.059,0.089,0.004,44080,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-05",24,24,6519,,0.013,0.001,2642.6,0.059,0.089,0.004,44464.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-06",24,24,6647,,0.014,0.001,2690,0.059,0.093,0.0041,45264.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-07",1,0.48,86.4,,0,0.001,35.184,0.059,0.003,0.011,591.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-09",23,22.2,5751.2,,0.012,0.001,2367.78,0.059,0.155,0.021,39845.32,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-10",24,24,7395,,0.015,0.001,3016.5,0.059,0.102,0.004,50760,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-11",24,24,6572,,0.013,0.001,2665,0.059,0.09,0.004,44844.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-12",24,24,6907,,0.014,0.001,2819.1,0.059,0.093,0.0039,47433.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-13",24,24,6864,,0.014,0.001,2789,0.059,0.095,0.004,46926.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-14",24,24,6838,,0.014,0.001,2761,0.059,0.093,0.004,46461.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-15",24,24,6773,,0.014,0.001,2742.2,0.059,0.091,0.004,46146.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-16",24,24,7409,,0.015,0.001,3007.9,0.059,0.102,0.004,50615.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-17",24,24,6837,,0.014,0.001,2757.5,0.059,0.094,0.004,46400.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-18",24,24,6550,,0.013,0.001,2648.5,0.059,0.089,0.004,44566.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-19",24,24,6407,,0.013,0.001,2603.5,0.059,0.086,0.0039,43811.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-20",24,24,6523,,0.013,0.001,2637,0.059,0.097,0.0043,44370.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-21",8,7.47,2191.9,,0.004,0.001,883.318,0.059,0.033,0.0054,14864.054,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-24",22,21.2,4974.92,,0.01,0.001,2057.952,0.059,0.157,0.0222,34628.112,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-27",1,0.93,22.32,,0,0.001,25.947,0.059,0.058,0.267,436.728,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-28",24,24,5988,,0.012,0.001,2442.2,0.059,0.11,0.0063,41095.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-29",24,24,5941,,0.012,0.001,2416.9,0.059,0.077,0.0038,40670.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-30",24,24,6080,,0.012,0.001,2465.3,0.059,0.082,0.004,41485.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-03-31",8,7.48,2148,,0.004,0.001,865.496,0.059,0.031,0.005,14564.22,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-01",21,20.28,4682.52,,0.01,0.001,1941.18,0.059,0.136,0.0218,32664.04,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-02",22,21.47,5219.84,,0.011,0.001,2114.976,0.059,0.072,0.0043,35589.67,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-04",23,22.93,5581.32,,0.012,0.001,2300.575,0.059,0.156,0.0168,38708.76,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-05",24,24,6298,,0.013,0.001,2537.8,0.059,0.085,0.004,42701.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-06",24,24,6643,,0.014,0.001,2678.6,0.059,0.083,0.0036,45068.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-07",24,24,6504,,0.013,0.001,2625.4,0.059,0.085,0.0038,44178.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-08",24,24,6267,,0.013,0.001,2531.3,0.059,0.083,0.0039,42590.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-09",24,24,7312,,0.015,0.001,2963.8,0.059,0.1,0.004,49873.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-10",24,24,6461,,0.013,0.001,2615.8,0.059,0.087,0.0039,44018.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-11",24,24,5934,,0.012,0.001,2427.3,0.059,0.103,0.0049,40845.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-12",24,24,5750,,0.012,0.001,2317.6,0.059,0.076,0.0039,39003.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-13",24,24,6109,,0.012,0.001,2475.2,0.059,0.082,0.004,41650.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-14",24,24,5951,,0.012,0.001,2415.4,0.059,0.079,0.0039,40645.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-15",24,24,6070,,0.012,0.001,2451.9,0.059,0.079,0.0038,41258.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-16",24,24,5899,,0.012,0.001,2399.5,0.059,0.08,0.004,40369.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-17",24,23.48,5542.36,,0.011,0.001,2255.696,0.059,0.075,0.0041,37956.692,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-20",22,21.18,4902.76,,0.01,0.001,2018.484,0.059,0.163,0.0198,33963.738,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-22",5,3.51,380.34,,0.001,0.001,192.286,0.0592,0.082,0.0928,3233.613,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-24",9,7.93,1650.28,,0.004,0.001,708.891,0.059,0.114,0.046,11928.19,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-28",9,8.67,1902.4,,0.004,0.001,822.887,0.0591,0.125,0.0529,13846.995,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-26",6,3.92,62.67,,0.002,0.001,476.678,0.059,0.474,0.1147,8020.568,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-28",12,11.37,1976.22,,0.007,0.001,1391.596,0.059,0.512,0.0516,23414.384,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-29",2,1.73,391.7,,0.001,0.001,211.871,0.059,0.009,0.0055,3564.547,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-01",12,10.56,2184.04,,0.007,0.001,1297.832,0.059,0.313,0.0461,21838.574,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-02",24,24,6235,,0.016,0.001,3193.9,0.059,0.105,0.0039,53747.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-03",24,24,6533,,0.016,0.001,3255,0.059,0.105,0.0038,54769.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-04",19,17.8,4440.56,,0.012,0.001,2406.62,0.059,0.142,0.0081,40499.096,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-05",1,0.53,104.41,,0,0.001,65.72,0.059,0.004,0.008,1105.951,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-08",9,7.9,1688.3,,0.005,0.001,1034.896,0.059,0.454,0.0676,17412.732,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-09",12,10.12,2476.14,,0.007,0.001,1357.89,0.059,0.213,0.0363,22848.314,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-10",14,13.7,3572.7,,0.01,0.001,1907.48,0.059,0.226,0.0181,32094.82,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-11",24,23.48,6358.12,,0.015,0.001,3001.748,0.059,0.1,0.004,50511.448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-17",12,10.87,2350.25,,0.008,0.001,1521.814,0.059,0.406,0.0474,25607.812,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-18",13,11.7,3135.1,,0.008,0.001,1665.635,0.059,0.216,0.0269,28028.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-22",15,13.92,3661.36,,0.01,0.001,2044.208,0.059,0.35,0.0378,34398.152,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-23",18,16.61,3883.6,,0.009,0.001,1697.124,0.0591,0.069,0.0058,28553.41,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-24",24,24,6685,,0.014,0.001,2746.5,0.059,0.092,0.004,46216.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-25",12,10.57,2317.79,,0.005,0.001,977.279,0.0591,0.061,0.0143,16448.429,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-26",11,8.96,1981.84,,0.004,0.001,858.796,0.059,0.065,0.0153,14451.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-27",1,0.75,106.5,,0,0.001,46.575,0.059,0.002,0.004,783.375,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-06-30",9,8.01,1758.88,,0.004,0.001,753.748,0.059,0.099,0.0489,12682.195,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-03",11,10.2,2497,,0.005,0.001,1048.47,0.059,0.105,0.0332,17644.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-05",9,8.2,1921,,0.004,0.001,817.4,0.059,0.094,0.0427,13756.24,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-06",13,12.38,3118.56,,0.007,0.001,1303.35,0.059,0.085,0.0231,21930.572,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-07",24,24,5303,,0.011,0.001,2196.8,0.059,0.069,0.0037,36964.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-08",24,24,5264,,0.011,0.001,2178.4,0.059,0.067,0.0036,36652.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-09",24,24,5503,,0.012,0.001,2283,0.059,0.076,0.004,38415.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-10",24,24,5954,,0.013,0.001,2489.2,0.059,0.081,0.0038,41885.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-11",24,24,5710,,0.012,0.001,2397,0.059,0.082,0.004,40336,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-12",24,24,5382,,0.011,0.001,2275.1,0.059,0.076,0.004,38279.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-13",24,24,6039,,0.013,0.001,2535.6,0.059,0.085,0.004,42667.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-14",24,24,5827,,0.012,0.001,2436.7,0.059,0.081,0.004,41003.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-15",24,24,4402,,0.009,0.001,1870.9,0.059,0.062,0.004,31482.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-16",24,24,5273,,0.011,0.001,2225.3,0.059,0.073,0.0039,37441.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-17",24,24,5178,,0.011,0.001,2184.3,0.059,0.072,0.0039,36753.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-18",24,24,5539,,0.012,0.001,2320.4,0.059,0.094,0.0046,39047.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-19",24,24,5230,,0.011,0.001,2199,0.059,0.07,0.0038,37002.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-20",24,24,5852,,0.012,0.001,2446.9,0.059,0.078,0.0038,41172.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-21",24,24,5767,,0.012,0.001,2414.9,0.059,0.077,0.0038,40633.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-22",24,24,5251,,0.011,0.001,2207,0.059,0.068,0.0036,37139.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-23",24,24,4490,,0.01,0.001,1900.5,0.059,0.056,0.0035,31978.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-24",24,24,4836,,0.011,0.001,2090,0.059,0.064,0.0036,35164.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-25",24,24,5320,,0.012,0.001,2302.3,0.059,0.077,0.004,38746.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-26",24,24,5741,,0.012,0.001,2398,0.059,0.077,0.0038,40349.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-27",24,24,6073,,0.013,0.001,2556.6,0.059,0.081,0.0037,43018,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-28",24,24,6203,,0.013,0.001,2611.3,0.059,0.087,0.004,43943.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-29",24,24,7105,,0.015,0.001,2964.2,0.059,0.101,0.004,49883.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-30",24,24,7070,,0.015,0.001,2941.6,0.059,0.099,0.004,49495.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-07-31",24,24,7076,,0.015,0.001,2929.1,0.059,0.099,0.004,49285.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-01",24,24,6236,,0.013,0.001,2604.3,0.059,0.087,0.004,43822.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-02",24,24,5369,,0.011,0.001,2260.6,0.059,0.073,0.0038,38038.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-03",24,24,5845,,0.012,0.001,2450.1,0.059,0.083,0.004,41230.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-04",24,24,5264,,0.011,0.001,2209.3,0.059,0.07,0.0038,37174.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-05",24,24,4721,,0.01,0.001,1988.8,0.059,0.061,0.0036,33467.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-06",24,24,4370,,0.009,0.001,1856.4,0.059,0.056,0.0036,31235.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-07",24,24,4606,,0.01,0.001,1941.5,0.059,0.064,0.0039,32669.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-08",24,24,5202,,0.011,0.001,2192.4,0.059,0.071,0.0038,36887.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-09",24,24,5395,,0.011,0.001,2274.8,0.059,0.074,0.0038,38279.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-10",24,24,5578,,0.012,0.001,2328.3,0.059,0.079,0.004,39174.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-11",24,24,4512,,0.01,0.001,1905.7,0.059,0.059,0.0037,32063.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-12",24,24,5703,,0.012,0.001,2398.9,0.059,0.076,0.0037,40361.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-13",24,24,6499,,0.014,0.001,2713.1,0.059,0.092,0.004,45651.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-14",24,24,7199,,0.015,0.001,3037.4,0.059,0.102,0.004,51110.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-15",24,24,7161,,0.015,0.001,3042.4,0.059,0.103,0.004,51195.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-16",24,24,7173,,0.015,0.001,3032.5,0.059,0.102,0.004,51026.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-17",24,24,7186,,0.015,0.001,3053.7,0.059,0.103,0.004,51384.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-18",24,24,7161,,0.015,0.001,3046.7,0.059,0.104,0.004,51265.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-19",24,24,7213,,0.015,0.001,3047.6,0.059,0.104,0.004,51283.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-20",24,24,7148,,0.015,0.001,2954.4,0.059,0.099,0.004,49712,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-21",24,24,7164,,0.015,0.001,2987.2,0.059,0.101,0.004,50264.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-22",24,24,6627,,0.014,0.001,2757.9,0.059,0.098,0.0042,46410.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-23",24,24,6802,,0.014,0.001,2837.1,0.059,0.096,0.004,47739.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-24",24,24,7268,,0.015,0.001,3040.4,0.059,0.103,0.004,51162.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-25",24,24,7176,,0.015,0.001,2988.7,0.059,0.105,0.0042,50289.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-26",24,24,7040,,0.015,0.001,2918.7,0.059,0.107,0.0044,49110.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-27",24,24,7127,,0.015,0.001,2960.7,0.059,0.1,0.004,49821,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-28",24,24,6126,,0.013,0.001,2566.7,0.059,0.086,0.004,43188.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-29",24,24,6012,,0.013,0.001,2499.7,0.059,0.085,0.004,42064.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-30",24,24,6450,,0.013,0.001,2659.6,0.059,0.097,0.0043,44754.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-08-31",24,24,5913,,0.012,0.001,2463.4,0.059,0.085,0.0041,41453.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-01",24,24,5655,,0.012,0.001,2354.7,0.059,0.078,0.0039,39616.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-02",24,24,4873,,0.011,0.001,2105.9,0.059,0.066,0.0037,35439.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-03",24,24,6155,,0.013,0.001,2598.2,0.059,0.087,0.004,43717.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-04",24,24,7221,,0.015,0.001,3013,0.059,0.101,0.004,50700.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-05",24,24,6811,,0.014,0.001,2865.2,0.059,0.096,0.004,48215.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-06",24,24,7092,,0.015,0.001,3013.3,0.059,0.101,0.004,50705.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-07",24,24,6405,,0.014,0.001,2682.5,0.059,0.095,0.0042,45138.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-08",24,24,6603,,0.014,0.001,2798.7,0.059,0.094,0.004,47093.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-09",24,24,6095,,0.013,0.001,2524.9,0.059,0.084,0.004,42484.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-10",24,24,5871,,0.012,0.001,2424.3,0.059,0.081,0.004,40790.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-11",24,23.17,4960.38,,0.01,0.001,2074.087,0.059,0.065,0.0047,34899.835,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-14",11,10.58,2635.44,,0.006,0.001,1121.564,0.059,0.125,0.0421,18873.778,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-15",23,22.45,5385.05,,0.011,0.001,2247.755,0.059,0.074,0.004,37820.85,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-16",18,17.52,4241.2,,0.009,0.001,1818.436,0.059,0.088,0.0093,30598.264,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-17",24,24,5980,,0.013,0.001,2501.7,0.059,0.084,0.004,42095.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-18",18,16.27,3821.7,,0.008,0.0009,1644.76,0.0557,0.07,0.0066,27677.176,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-19",20,19.27,4413.35,,0.01,0.001,1924.424,0.059,0.078,0.006,32383.136,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-20",20,17.96,4369.27,,0.009,0.001,1872.643,0.0591,0.081,0.007,31510.882,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-21",10,8.76,2062.66,,0.004,0.001,885.09,0.0591,0.09,0.0376,14894.554,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-22",8,6.92,1490.12,,0.003,0.001,605.26,0.059,0.086,0.0464,10185.457,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-23",9,7.66,1747.82,,0.004,0.001,755.173,0.059,0.094,0.0446,12706.359,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-24",13,11.85,2307.74,,0.005,0.001,1046.252,0.059,0.088,0.0302,17609.688,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-27",11,8.78,2066.75,,0.005,0.001,901.144,0.059,0.121,0.049,15165.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-28",17,15.87,3823.09,,0.008,0.001,1678.993,0.059,0.117,0.0242,28256.223,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-29",18,17.4,4376.8,,0.01,0.001,1899,0.059,0.118,0.0203,31955.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-09-30",24,24,6690,,0.014,0.001,2806.5,0.059,0.095,0.004,47226.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-01",24,24,6661,,0.014,0.001,2779.9,0.059,0.095,0.004,46777.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-02",24,24,6555,,0.014,0.001,2744.6,0.059,0.092,0.004,46180.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-03",16,14.62,3411.1,,0.007,0.001,1475.947,0.0591,0.101,0.0201,24834.372,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-04",15,14.95,3498.15,,0.008,0.001,1505.48,0.059,0.127,0.0195,25331.655,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-05",23,22.5,5985.5,,0.012,0.001,2468.6,0.059,0.085,0.0042,41540.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-06",18,17.37,4194.22,,0.009,0.001,1794.284,0.059,0.109,0.0208,30191.159,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-07",24,23.48,6248.36,,0.013,0.001,2561.76,0.059,0.089,0.0043,43106.268,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-12",12,11.7,2817,,0.006,0.001,1184.22,0.059,0.144,0.0431,19924.35,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-13",24,24,6017,,0.012,0.001,2474.7,0.059,0.085,0.0041,41640.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-14",24,24,6483,,0.014,0.001,2684.3,0.059,0.093,0.0041,45168.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-15",24,24,6548,,0.014,0.001,2742.5,0.059,0.096,0.0042,46144.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-16",24,24,6525,,0.014,0.001,2732.2,0.059,0.095,0.0041,45974.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-17",24,24,6261,,0.013,0.001,2591.6,0.059,0.09,0.0042,43606.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-18",22,20.88,4930.54,,0.01,0.001,2068.281,0.059,0.106,0.0116,34800.653,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-19",24,24,6342,,0.013,0.001,2606.9,0.059,0.091,0.0042,43868.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-20",24,24,6324,,0.013,0.001,2626.2,0.059,0.092,0.0042,44191.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-21",24,24,6618,,0.014,0.001,2748.2,0.059,0.095,0.0041,46244.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-22",24,24,6622,,0.014,0.001,2713.3,0.059,0.094,0.0041,45654.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-23",24,24,6664,,0.014,0.001,2721.2,0.059,0.097,0.0042,45788.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-24",24,24,6117,,0.013,0.001,2503.9,0.059,0.086,0.0041,42130.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-25",24,24,5989,,0.012,0.001,2474.2,0.059,0.084,0.004,41630.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-26",24,24,6608,,0.014,0.001,2712.9,0.059,0.098,0.0043,45652.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-27",24,24,7157,,0.015,0.001,2962.8,0.059,0.106,0.0043,49857.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-28",24,24,6086,,0.013,0.001,2505.6,0.059,0.066,0.0031,42162.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-29",24,24,6237,,0.013,0.001,2553.9,0.059,0.071,0.0033,42970.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-30",24,24,6894,,0.014,0.001,2835.1,0.059,0.074,0.0031,47705.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-10-31",24,24,6090,,0.013,0.001,2502.1,0.059,0.082,0.0038,42100.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-01",24,24,6472,,0.013,0.001,2667,0.059,0.078,0.0035,44879.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-02",24,24,6750,,0.014,0.001,2782.5,0.059,0.072,0.0031,46820.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-03",24,24,6726,,0.014,0.001,2766.9,0.059,0.071,0.003,46559.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-04",24,24,6812,,0.014,0.001,2804.1,0.059,0.071,0.003,47184.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-05",24,24,6739,,0.014,0.001,2777.2,0.059,0.07,0.003,46729.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-06",24,24,6116,,0.013,0.001,2525.4,0.059,0.062,0.0029,42491.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-07",24,24,6069,,0.013,0.001,2495.3,0.059,0.03,0.0014,41987.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-08",24,24,6135,,0.013,0.001,2516.8,0.059,0.052,0.0024,42350.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-09",24,24,6363,,0.013,0.001,2625,0.059,0.06,0.0026,44169,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-10",24,24,6579,,0.014,0.001,2699.2,0.059,0.063,0.0027,45420.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-11",24,24,6413,,0.013,0.001,2625.1,0.059,0.058,0.0026,44171.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-12",24,24,6485,,0.013,0.001,2661.7,0.059,0.06,0.0026,44787,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-13",24,24,6006,,0.012,0.001,2453.5,0.059,0.055,0.0026,41280.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-14",24,24,5780,,0.012,0.001,2422.2,0.059,0.049,0.0024,40758.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-15",24,24,6022,,0.012,0.001,2471.6,0.059,0.054,0.0026,41590.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-16",24,24,6323,,0.013,0.001,2597,0.059,0.066,0.003,43703.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-17",24,24,6455,,0.013,0.001,2664,0.059,0.063,0.0028,44826.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-18",24,24,6240,,0.013,0.001,2570.3,0.059,0.06,0.0028,43247.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-19",24,24,5960,,0.012,0.001,2471.8,0.059,0.052,0.0025,41593.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-20",24,24,6645,,0.014,0.001,2732.8,0.059,0.063,0.0027,45984.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-21",24,24,6494,,0.013,0.001,2662.8,0.059,0.06,0.0026,44804.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-22",24,24,6183,,0.013,0.001,2540,0.059,0.055,0.0025,42742.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-23",24,24,5937,,0.013,0.001,2477.5,0.059,0.052,0.0025,41686.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-24",24,24,6551,,0.014,0.001,2701.9,0.059,0.061,0.0026,45457.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-25",24,23.48,5906.84,,0.012,0.001,2431.032,0.059,0.062,0.0033,40909.312,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-26",1,0.68,6.12,,0,0.001,18.836,0.059,0.037,0.232,317.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-27",24,24,5541,,0.012,0.001,2379.8,0.059,0.1,0.0076,40040.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-28",24,24,6397,,0.013,0.001,2635.1,0.059,0.064,0.0029,44345.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-29",24,24,6333,,0.013,0.001,2613.5,0.059,0.063,0.0028,43979.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-11-30",24,24,6595,,0.014,0.001,2731.5,0.059,0.065,0.0028,45962.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-01",24,24,6807,,0.014,0.001,2819.3,0.059,0.07,0.0029,47441.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-02",24,24,6789,,0.014,0.001,2811.4,0.059,0.069,0.0029,47305.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-03",24,24,7012,,0.015,0.001,2897.8,0.059,0.073,0.003,48764.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-04",24,24,7031,,0.015,0.001,2907.6,0.059,0.073,0.003,48925.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-05",24,24,6837,,0.014,0.001,2837.8,0.059,0.07,0.0029,47751.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-06",24,24,6694,,0.014,0.001,2769.7,0.059,0.064,0.0027,46608.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-07",24,24,6913,,0.014,0.001,2865.4,0.059,0.072,0.003,48218.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-08",24,24,6741,,0.014,0.001,2784.8,0.059,0.069,0.0029,46855.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-09",24,24,6944,,0.014,0.001,2868.5,0.059,0.075,0.0031,48269.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-10",24,24,6867,,0.014,0.001,2849.3,0.059,0.068,0.0028,47946.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-11",24,24,6705,,0.014,0.001,2782.3,0.059,0.064,0.0027,46811.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-12",24,24,6689,,0.014,0.001,2770.9,0.059,0.071,0.003,46626.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-13",24,24,6490,,0.014,0.001,2693.3,0.059,0.067,0.0029,45319.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-14",1,0.27,23.76,,0,0.001,11.583,0.059,0.001,0.013,194.967,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-16",9,8.62,2208.78,,0.005,0.001,946.94,0.059,0.093,0.036,15933.418,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-17",24,24,6768,,0.014,0.001,2791.3,0.059,0.07,0.003,46972.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-18",24,24,6466,,0.014,0.001,2691.8,0.059,0.069,0.003,45290,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-19",24,24,6564,,0.014,0.001,2726.9,0.059,0.07,0.003,45886.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-20",24,24,6360,,0.013,0.001,2638.8,0.059,0.066,0.003,44400.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-21",24,24,6619,,0.014,0.001,2742.4,0.059,0.07,0.003,46144.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-22",24,24,6483,,0.014,0.001,2701.8,0.059,0.069,0.003,45458.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-23",24,24,6783,,0.014,0.001,2809.2,0.059,0.07,0.003,47269,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-24",24,24,6713,,0.014,0.001,2771.2,0.059,0.07,0.003,46631,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-25",24,24,6488,,0.013,0.001,2665.9,0.059,0.073,0.0033,44861.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-26",24,24,6329,,0.013,0.001,2612.5,0.059,0.072,0.0033,43963.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-27",24,24,6520,,0.014,0.001,2692.9,0.059,0.071,0.0031,45312.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-28",24,24,6835,,0.014,0.001,2826.8,0.059,0.074,0.0031,47566.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-29",24,24,6852,,0.014,0.001,2831.4,0.059,0.071,0.003,47646.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-30",24,24,6745,,0.014,0.001,2780.9,0.059,0.074,0.0032,46796,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT1",,"2020-12-31",24,24,6409,,0.013,0.001,2652.3,0.059,0.074,0.0033,44627.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-01",3,2.43,395.71,,0.001,0.001,270.64,0.059,0.009,0.0063,4553.607,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-02",23,22.63,3325.04,,0.012,0.001,2297.825,0.059,0.122,0.0153,38664.675,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-03",24,23.92,4820.72,,0.014,0.001,2686.948,0.059,0.068,0.0029,45209.436,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-04",1,0.02,0,,0,0,0,0,0,0,0.004,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-06",20,19.47,4457.29,,0.01,0.001,1931.908,0.059,0.118,0.0201,32507.486,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-07",23,22.48,6131.84,,0.013,0.001,2524.796,0.059,0.055,0.0027,42483.892,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-08",3,2.7,78.9,,0.001,0.001,102.49,0.059,0.058,0.0887,1723.75,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-09",24,24,5968,,0.013,0.001,2501.5,0.059,0.045,0.002,42094.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-10",24,24,6791,,0.014,0.001,2791.3,0.059,0.074,0.003,46969.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-11",9,8.52,2452.2,,0.005,0.001,1004.952,0.059,0.029,0.0039,16911.26,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-12",1,0.45,3.15,,0,0.001,11.79,0.059,0.016,0.164,198.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-13",24,24,5605,,0.012,0.001,2422.6,0.059,0.097,0.0079,40770.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-14",24,24,6692,,0.014,0.001,2754.8,0.059,0.078,0.0033,46354.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-15",24,24,6821,,0.014,0.001,2816.4,0.059,0.073,0.003,47394.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-16",24,24,6761,,0.014,0.001,2782.6,0.059,0.07,0.0029,46820.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-17",24,24,6800,,0.014,0.001,2791.9,0.059,0.075,0.0031,46979.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-18",24,24,6695,,0.014,0.001,2755,0.059,0.071,0.003,46357.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-19",24,24,6151,,0.013,0.001,2539.4,0.059,0.044,0.0019,42732.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-20",24,24,7250,,0.015,0.001,2979.3,0.059,0.096,0.0038,50134.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-21",24,24,6740,,0.014,0.001,2768.9,0.059,0.072,0.003,46595.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-22",24,24,5949,,0.012,0.001,2469.1,0.059,0.045,0.002,41549.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-23",24,24,6622,,0.014,0.001,2733.9,0.059,0.067,0.0028,46002.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-24",24,23.5,5909,,0.012,0.001,2449.6,0.059,0.042,0.0022,41224.95,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-27",6,5.8,638.4,,0.002,0.001,354.74,0.059,0.066,0.0447,5969.16,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-28",23,22.52,5312.24,,0.011,0.001,2242.984,0.059,0.038,0.0022,37741.852,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-29",7,6.7,1176.9,,0.003,0.001,563.38,0.0591,0.086,0.0423,9478.55,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-30",24,24,5902,,0.012,0.001,2463.5,0.059,0.04,0.0018,41452.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-01-31",24,23.52,5511.68,,0.012,0.001,2318.468,0.059,0.035,0.0019,39011.984,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-02",1,0.78,6.24,,0,0.001,22.152,0.059,0.037,0.196,372.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-03",24,24,5570,,0.012,0.001,2397.2,0.059,0.082,0.0072,40341.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-04",24,24,6920,,0.014,0.001,2840.4,0.059,0.076,0.0031,47795.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-05",24,24,6780,,0.014,0.001,2790.5,0.059,0.075,0.0031,46954.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-06",24,24,6633,,0.014,0.001,2723.2,0.059,0.069,0.0029,45823.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-07",24,23.5,6111.5,,0.013,0.001,2520.4,0.059,0.055,0.0028,42410.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-09",1,0.7,5.6,,0,0.001,19.6,0.059,0.033,0.201,329.42,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-10",24,24,5559,,0.012,0.001,2389.4,0.059,0.108,0.0088,40203.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-11",24,24,5890,,0.012,0.001,2445,0.059,0.041,0.0018,41140.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-12",24,24,5975,,0.012,0.001,2469.9,0.059,0.041,0.0018,41558.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-13",24,24,6661,,0.014,0.001,2735.4,0.059,0.074,0.0031,46031.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-14",1,0.97,224.07,,0,0.001,91.568,0.059,0.005,0.007,1541.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-17",15,14.82,2931.56,,0.007,0.001,1327.042,0.059,0.142,0.0299,22328.252,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-18",24,24,6928,,0.014,0.001,2856.5,0.059,0.086,0.0035,48067.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-19",24,24,7097,,0.015,0.001,2914.9,0.059,0.092,0.0038,49050.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-20",24,24,7077,,0.015,0.001,2898.9,0.059,0.091,0.0037,48778.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-21",24,23.48,5927.24,,0.012,0.001,2439.876,0.059,0.045,0.0023,41056.448,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-24",11,10.72,2324.76,,0.005,0.001,1066.076,0.059,0.138,0.0392,17936.38,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-25",24,24,5579,,0.012,0.001,2405.2,0.059,0.042,0.0018,40468.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-26",18,17.07,4563.93,,0.01,0.001,1921.837,0.059,0.105,0.0148,32339.626,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-27",24,24,6192,,0.013,0.001,2567.4,0.059,0.048,0.0021,43204,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-28",24,23.52,5789.08,,0.012,0.001,2390.884,0.059,0.047,0.0024,40233.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-03",16,15.18,3042.36,,0.007,0.001,1386.96,0.059,0.149,0.0298,23341.516,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-04",24,24,6449,,0.013,0.001,2656.9,0.059,0.069,0.0029,44709.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-05",24,24,6535,,0.014,0.001,2683.3,0.059,0.069,0.0029,45144.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-06",24,24,6667,,0.014,0.001,2729.6,0.059,0.072,0.003,45931.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-07",1,0.5,89.5,,0,0.001,36.25,0.059,0.004,0.012,610.25,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-08",4,3.72,343.76,,0.001,0.001,212.588,0.0593,0.061,0.0668,3575.164,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-09",24,24,6355,,0.013,0.001,2645.5,0.059,0.059,0.0025,44513.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-10",24,24,7371,,0.015,0.001,3029.8,0.059,0.102,0.004,50977.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-11",24,24,6590,,0.014,0.001,2699.5,0.059,0.076,0.0033,45425.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-12",24,24,6860,,0.014,0.001,2826,0.059,0.085,0.0035,47554.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-13",24,24,6777,,0.014,0.001,2785.4,0.059,0.083,0.0035,46867.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-14",24,24,6849,,0.014,0.001,2795.5,0.059,0.077,0.0032,47036.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-15",24,24,6778,,0.014,0.001,2774.9,0.059,0.079,0.0033,46691.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-16",24,24,7401,,0.015,0.001,3028.3,0.059,0.102,0.004,50959.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-17",24,24,6861,,0.014,0.001,2802.6,0.059,0.081,0.0034,47163.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-18",24,24,6564,,0.014,0.001,2687.7,0.059,0.078,0.0033,45228.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-19",24,24,6417,,0.013,0.001,2638.6,0.059,0.074,0.0032,44398.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-20",24,24,6545,,0.014,0.001,2677.1,0.059,0.078,0.0033,45047.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-21",8,7.47,2195.37,,0.005,0.001,893.358,0.059,0.031,0.0049,15028.47,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-22",7,6.73,880.84,,0.002,0.001,451.348,0.059,0.081,0.0486,7594.604,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-23",10,8.87,1292.81,,0.003,0.001,640.218,0.059,0.084,0.0373,10772.686,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-24",24,23.48,5690,,0.012,0.001,2382.872,0.059,0.056,0.003,40100.168,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-27",7,6.93,904.37,,0.002,0.001,474.991,0.059,0.096,0.0483,7993.376,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-28",24,24,6103,,0.013,0.001,2519.2,0.059,0.056,0.0025,42392.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-29",24,24,5967,,0.012,0.001,2460.8,0.059,0.054,0.0025,41404.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-30",24,24,6103,,0.013,0.001,2504.1,0.059,0.055,0.0025,42135.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-03-31",14,13.37,2987.83,,0.007,0.001,1290.773,0.059,0.096,0.0184,21721.189,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-01",24,24,5577,,0.012,0.001,2347.3,0.059,0.051,0.0025,39497.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-02",22,21.47,5243.78,,0.011,0.001,2154.675,0.059,0.047,0.003,36260.371,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-03",4,3.72,290.76,,0.001,0.001,194.284,0.059,0.079,0.0858,3269.944,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-04",24,24,6091,,0.013,0.001,2531.1,0.059,0.055,0.0025,42591.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-05",24,24,6317,,0.013,0.001,2577.8,0.059,0.062,0.0028,43377.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-06",24,24,6657,,0.014,0.001,2719.2,0.059,0.072,0.003,45752.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-07",24,24,6520,,0.013,0.001,2664.6,0.059,0.071,0.0031,44837.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-08",24,24,6289,,0.013,0.001,2573.2,0.059,0.061,0.0028,43299.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-09",24,24,7338,,0.015,0.001,2993.3,0.059,0.101,0.004,50368,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-10",24,24,6514,,0.013,0.001,2658,0.059,0.074,0.0032,44726,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-11",24,24,5969,,0.012,0.001,2474.5,0.059,0.058,0.0027,41639.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-12",24,24,5788,,0.012,0.001,2367.2,0.059,0.047,0.0024,39831,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-13",24,24,6186,,0.013,0.001,2532.5,0.059,0.059,0.0027,42613,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-14",24,24,6064,,0.013,0.001,2482.2,0.059,0.057,0.0026,41773.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-15",24,24,6149,,0.013,0.001,2506.4,0.059,0.062,0.0029,42174.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-16",24,24,5988,,0.012,0.001,2453.2,0.059,0.059,0.0028,41279.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-17",24,23.48,5588.84,,0.012,0.001,2303.508,0.059,0.054,0.0029,38761.696,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-19",7,6.7,769.6,,0.002,0.001,428.28,0.059,0.086,0.052,7205.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-20",24,23.23,5561.57,,0.012,0.001,2313.389,0.059,0.051,0.0033,38930.694,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-22",16,14.08,2185.92,,0.005,0.001,1051.236,0.0591,0.096,0.0255,17687.434,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-23",3,2.17,361.21,,0.001,0.001,162.649,0.059,0.002,0.0087,2737.057,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-24",14,13.3,2516.2,,0.006,0.001,1146.48,0.0591,0.107,0.027,19285.31,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-27",11,10.67,1988.36,,0.005,0.001,921.457,0.059,0.113,0.0362,15503.187,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-28",22,22,4679,,0.01,0.001,2026.9,0.059,0.043,0.0024,34106.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-29",11,10.68,2041.44,,0.005,0.001,933.632,0.059,0.077,0.0238,15708.512,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-04-30",8,7.17,1265.25,,0.003,0.001,561.719,0.059,0.007,0.004,9451.296,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-11",1,0.05,0,,0,0,0,0,0,0,0.01,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-27",7,5.61,490.17,,0.002,0.001,301.23,0.059,0.098,0.0617,5068.672,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-28",6,5.17,889.17,,0.002,0.001,410.323,0.0592,0.048,0.034,6903.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-29",6,5.26,665.78,,0.002,0.001,352.645,0.059,0.081,0.055,5934.547,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-30",20,18.29,3441.72,,0.008,0.001,1539.14,0.059,0.063,0.0076,25899.516,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-05-31",17,15.87,2955.32,,0.007,0.001,1318.377,0.059,0.065,0.0201,22184.715,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-01",24,24,4637,,0.01,0.001,2065.9,0.059,0.04,0.0023,34765.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-02",24,24,5732,,0.013,0.001,2501.7,0.059,0.067,0.003,42095.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-03",24,24,5937,,0.013,0.001,2575.8,0.059,0.072,0.0032,43343,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-04",15,13.91,3402.12,,0.008,0.001,1504.994,0.059,0.081,0.0168,25324.801,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-05",1,0.53,82.68,,0,0.001,37.842,0.059,0.003,0.008,637.007,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-08",15,14.43,2561.58,,0.006,0.001,1226.807,0.0591,0.123,0.0307,20645.526,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-09",16,15.01,2990.15,,0.007,0.001,1393.551,0.059,0.096,0.0188,23452.409,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-10",17,16.37,3774.22,,0.009,0.001,1705.195,0.0591,0.08,0.0126,28689.939,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-11",24,23.48,5909.44,,0.013,0.001,2517.184,0.059,0.073,0.0035,42353.936,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-14",12,10.88,2131.84,,0.005,0.001,982.224,0.0591,0.118,0.0332,16528.722,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-17",15,14.37,2659.46,,0.007,0.001,1299.11,0.059,0.112,0.0233,21861.253,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-18",17,15.62,3511.97,,0.008,0.001,1591.606,0.0591,0.083,0.0164,26779.839,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-20",4,3.95,293.55,,0.001,0.001,198.91,0.0595,0.056,0.0523,3345.45,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-21",24,24,4857,,0.011,0.001,2133.8,0.059,0.046,0.0024,35906.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-22",24,24,5376,,0.012,0.001,2410.1,0.059,0.06,0.0028,40553,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-23",13,11.78,2892.52,,0.006,0.001,1238.458,0.059,0.063,0.0154,20839.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-24",24,24,6663,,0.014,0.001,2758.7,0.059,0.08,0.0034,46420.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-25",16,14.57,3060.75,,0.007,0.001,1323.341,0.0591,0.061,0.0094,22266.87,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-26",19,18.22,4044.66,,0.009,0.001,1764.016,0.059,0.069,0.0081,29687.524,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-27",1,0.75,108,,0,0.001,47.7,0.059,0.002,0.004,802.125,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-06-30",15,13.93,2551.55,,0.006,0.001,1167.416,0.0591,0.113,0.0287,19642.356,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-03",16,15.22,3204.2,,0.007,0.001,1416.756,0.059,0.096,0.0201,23842.496,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-05",14,13.3,2648,,0.006,0.001,1194.47,0.059,0.108,0.0266,20101.48,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-06",22,21.35,4874.55,,0.011,0.001,2091.445,0.059,0.068,0.0042,35194.145,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-07",24,24,5325,,0.011,0.001,2228.8,0.059,0.055,0.0028,37503.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-08",24,24,5279,,0.011,0.001,2206.9,0.059,0.055,0.0028,37133.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-09",24,24,5517,,0.012,0.001,2310.5,0.059,0.06,0.0029,38876.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-10",24,24,5904,,0.012,0.001,2461,0.059,0.067,0.0031,41409.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-11",24,24,5666,,0.012,0.001,2368.8,0.059,0.063,0.003,39864.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-12",24,24,5342,,0.011,0.001,2250.5,0.059,0.057,0.0028,37869.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-13",24,24,5976,,0.013,0.001,2493.9,0.059,0.071,0.0033,41965.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-14",24,24,5780,,0.012,0.001,2406.3,0.059,0.066,0.0031,40494,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-15",24,24,4399,,0.009,0.001,1868.3,0.059,0.033,0.0021,31438.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-16",24,24,5235,,0.011,0.001,2204.7,0.059,0.055,0.0028,37099.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-17",24,24,5151,,0.011,0.001,2166.3,0.059,0.051,0.0026,36450.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-18",24,24,5500,,0.012,0.001,2296.4,0.059,0.06,0.0029,38637.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-19",24,24,5197,,0.011,0.001,2181.5,0.059,0.053,0.0027,36706.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-20",24,24,5815,,0.012,0.001,2420.2,0.059,0.068,0.0032,40723,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-21",24,24,5725,,0.012,0.001,2386.4,0.059,0.065,0.003,40152.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-22",24,24,5223,,0.011,0.001,2185.8,0.059,0.053,0.0027,36783.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-23",24,24,4479,,0.01,0.001,1897.1,0.059,0.034,0.0021,31922.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-24",8,7.3,1303.1,,0.003,0.001,558.12,0.059,0.009,0.002,9390.83,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-25",11,10.5,2569.5,,0.006,0.001,1094.7,0.059,0.081,0.0267,18421,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-26",24,24,5697,,0.012,0.001,2370.4,0.059,0.063,0.003,39884.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-27",24,24,6004,,0.013,0.001,2514.1,0.059,0.072,0.0033,42306.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-28",24,24,6144,,0.013,0.001,2571.2,0.059,0.073,0.0033,43264.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-29",24,24,7016,,0.015,0.001,2915.8,0.059,0.098,0.004,49063.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-30",24,24,6988,,0.015,0.001,2898.3,0.059,0.098,0.004,48771.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-07-31",24,24,6997,,0.015,0.001,2888.1,0.059,0.097,0.004,48595.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-01",24,24,6180,,0.013,0.001,2571.2,0.059,0.075,0.0033,43266.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-02",24,24,5329,,0.011,0.001,2237.1,0.059,0.055,0.0028,37648.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-03",24,24,5805,,0.012,0.001,2424.4,0.059,0.067,0.0031,40794.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-04",24,24,5236,,0.011,0.001,2191.3,0.059,0.053,0.0027,36877,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-05",24,24,4701,,0.01,0.001,1979.8,0.059,0.04,0.0023,33313.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-06",24,24,4359,,0.009,0.001,1852.5,0.059,0.031,0.002,31169.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-07",24,24,4600,,0.01,0.001,1936.7,0.059,0.037,0.0023,32586.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-08",24,24,5164,,0.011,0.001,2172.2,0.059,0.052,0.0026,36553.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-09",24,24,5359,,0.011,0.001,2253.2,0.059,0.057,0.0028,37911.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-10",24,24,5546,,0.012,0.001,2308,0.059,0.062,0.003,38838,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-11",24,24,4505,,0.01,0.001,1900.9,0.059,0.034,0.0021,31986.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-12",24,24,5656,,0.012,0.001,2367.3,0.059,0.063,0.003,39835.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-13",24,24,6434,,0.013,0.001,2672.1,0.059,0.079,0.0035,44957,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-14",24,24,7094,,0.015,0.001,2972.3,0.059,0.1,0.004,50014.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-15",24,24,7041,,0.015,0.001,2964.1,0.059,0.099,0.004,49873.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-16",24,24,7060,,0.015,0.001,2956.1,0.059,0.099,0.004,49737.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-17",24,24,7067,,0.015,0.001,2971,0.059,0.099,0.004,49993.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-18",24,24,7038,,0.015,0.001,2965.3,0.059,0.1,0.004,49894.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-19",24,24,7098,,0.015,0.001,2973.9,0.059,0.1,0.004,50038.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-20",24,24,7079,,0.015,0.001,2916.6,0.059,0.098,0.004,49075.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-21",24,24,7088,,0.015,0.001,2928.1,0.059,0.098,0.004,49269.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-22",24,24,6553,,0.014,0.001,2712,0.059,0.083,0.0036,45635.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-23",24,24,6719,,0.014,0.001,2785.1,0.059,0.088,0.0037,46863.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-24",24,24,7150,,0.015,0.001,2965.3,0.059,0.1,0.004,49895.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-25",24,24,7074,,0.015,0.001,2921.8,0.059,0.098,0.004,49163.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-26",24,24,6948,,0.014,0.001,2862.5,0.059,0.096,0.004,48167.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-27",24,24,7030,,0.015,0.001,2900,0.059,0.098,0.004,48795.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-28",24,24,6040,,0.013,0.001,2504.9,0.059,0.071,0.0032,42148.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-29",24,24,5960,,0.012,0.001,2465.9,0.059,0.069,0.0032,41496.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-30",24,24,6399,,0.013,0.001,2622.9,0.059,0.085,0.0038,44134.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-08-31",24,24,5865,,0.012,0.001,2428.9,0.059,0.067,0.0031,40872.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-01",24,24,5622,,0.012,0.001,2336.3,0.059,0.061,0.003,39315.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-02",8,7.43,1306.42,,0.003,0.001,560.123,0.059,0.01,0.0026,9425.862,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-03",21,20.45,5241.75,,0.011,0.001,2196.96,0.059,0.107,0.0134,36965.325,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-04",24,24,7091,,0.015,0.001,2936.6,0.059,0.099,0.004,49417.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-05",24,24,6715,,0.014,0.001,2801.6,0.059,0.09,0.0038,47142.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-06",24,24,7016,,0.015,0.001,2950.2,0.059,0.099,0.004,49643.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-07",24,24,6390,,0.013,0.001,2652.8,0.059,0.082,0.0036,44637.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-08",24,24,6552,,0.014,0.001,2755.3,0.059,0.086,0.0037,46363,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-09",24,24,6054,,0.013,0.001,2503.8,0.059,0.069,0.0032,42133.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-10",24,24,5848,,0.012,0.001,2409.4,0.059,0.059,0.0028,40546.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-11",24,23.17,4949.55,,0.01,0.001,2063.923,0.059,0.045,0.0034,34729.011,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-12",7,6.78,882.24,,0.002,0.001,450.304,0.0591,0.066,0.0373,7574.146,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-13",10,9.07,1231.14,,0.003,0.001,610.005,0.059,0.073,0.0273,10265.925,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-14",18,16.32,3690.04,,0.008,0.001,1594.548,0.0591,0.089,0.0114,26832.98,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-15",23,22.52,5358,,0.011,0.001,2225.356,0.059,0.059,0.0032,37448.748,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-16",13,12.65,3283.6,,0.007,0.001,1376.945,0.0591,0.087,0.0178,23166.66,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-17",24,24,5936,,0.012,0.001,2472,0.059,0.068,0.0031,41594.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-18",14,12.05,2998.16,,0.006,0.0009,1263.19,0.0548,0.081,0.0162,21256.016,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-19",11,10.43,2678.02,,0.006,0.001,1136.792,0.059,0.085,0.026,19129.33,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-20",16,14.1,3536.16,,0.008,0.001,1491.382,0.059,0.082,0.0169,25096.253,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-21",15,13.63,2855.81,,0.006,0.001,1269.759,0.059,0.085,0.0219,21369.772,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-22",14,12.85,2635.34,,0.006,0.001,1165.206,0.059,0.085,0.0234,19607.637,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-23",14,12.76,2500.74,,0.006,0.001,1131.317,0.059,0.09,0.0249,19037.196,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-24",8,7.16,1594.44,,0.003,0.001,685.144,0.059,0.077,0.0339,11528.56,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-27",15,13.55,2847.76,,0.006,0.0009,1281.783,0.0591,0.111,0.0209,21569.395,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-28",13,12.2,3068.5,,0.007,0.001,1325.21,0.059,0.096,0.0221,22298.72,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-29",14,13.78,3618.38,,0.008,0.001,1534.394,0.059,0.096,0.0175,25817.888,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-09-30",24,24,6646,,0.014,0.001,2781.3,0.059,0.086,0.0036,46801.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-01",24,24,6598,,0.014,0.001,2741.5,0.059,0.086,0.0037,46132.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-02",24,24,6493,,0.014,0.001,2697.8,0.059,0.081,0.0035,45397.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-03",12,10.83,2665.52,,0.006,0.001,1125.918,0.059,0.082,0.0223,18947.514,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-04",11,10.87,2764.71,,0.006,0.001,1152.679,0.059,0.082,0.0194,19395.167,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-05",23,22.5,5934.5,,0.012,0.001,2435.75,0.059,0.073,0.0037,40990.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-06",13,12.73,3314.44,,0.007,0.001,1379.9,0.059,0.091,0.0185,23217.031,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-07",24,23.5,6190,,0.013,0.001,2527.25,0.059,0.079,0.0038,42527.15,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-11",23,22.7,3967.6,,0.009,0.001,1806.36,0.059,0.156,0.0212,30397.93,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-12",24,24,5299,,0.011,0.001,2244.3,0.059,0.056,0.0028,37763.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-13",24,24,5972,,0.012,0.001,2447,0.059,0.065,0.0031,41175.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-14",24,24,6421,,0.013,0.001,2642.8,0.059,0.078,0.0034,44472.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-15",24,24,6483,,0.014,0.001,2699.2,0.059,0.082,0.0035,45422.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-16",24,24,6461,,0.014,0.001,2685.3,0.059,0.082,0.0035,45184.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-17",24,24,6205,,0.013,0.001,2552.1,0.059,0.074,0.0034,42945.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-18",24,24,5659,,0.012,0.001,2384.4,0.059,0.057,0.0028,40122.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-19",24,24,6284,,0.013,0.001,2563.4,0.059,0.071,0.0032,43134.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-20",24,24,6260,,0.013,0.001,2577.6,0.059,0.074,0.0033,43373.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-21",24,24,6520,,0.014,0.001,2682,0.059,0.08,0.0035,45128,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-22",24,24,6591,,0.014,0.001,2683.4,0.059,0.08,0.0035,45153,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-23",24,24,6619,,0.014,0.001,2695.1,0.059,0.08,0.0035,45352.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-24",24,24,6092,,0.013,0.001,2483.5,0.059,0.063,0.003,41790.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-25",24,24,5963,,0.012,0.001,2448.9,0.059,0.057,0.0027,41208.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-26",24,24,6560,,0.014,0.001,2678.5,0.059,0.075,0.0033,45070.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-27",24,24,7078,,0.015,0.001,2906.8,0.059,0.093,0.0038,48911.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-28",24,24,6200,,0.013,0.001,2532.2,0.059,0.069,0.0032,42610.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-29",24,24,5739,,0.012,0.001,2374.2,0.059,0.058,0.0028,39950.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-30",24,24,6766,,0.014,0.001,2741.5,0.059,0.084,0.0036,46130.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-10-31",24,24,6071,,0.013,0.001,2480.6,0.059,0.062,0.0029,41741.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-01",24,24,6424,,0.013,0.001,2627.4,0.059,0.072,0.0032,44212.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-02",24,24,6678,,0.014,0.001,2729.9,0.059,0.082,0.0035,45933.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-03",24,24,6663,,0.014,0.001,2717.8,0.059,0.078,0.0033,45735.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-04",24,24,6742,,0.014,0.001,2753.1,0.059,0.08,0.0034,46324.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-05",24,24,6685,,0.014,0.001,2732.2,0.059,0.081,0.0035,45968.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-06",24,24,6074,,0.013,0.001,2492.3,0.059,0.068,0.0031,41936,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-07",24,24,6042,,0.012,0.001,2472.5,0.059,0.063,0.0029,41596.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-08",24,24,6106,,0.013,0.001,2492.4,0.059,0.058,0.0027,41937,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-09",24,24,6312,,0.013,0.001,2590.8,0.059,0.072,0.0032,43592.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-10",24,24,6531,,0.013,0.001,2668.5,0.059,0.076,0.0033,44907,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-11",24,24,6373,,0.013,0.001,2600.2,0.059,0.07,0.0031,43754.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-12",24,24,6436,,0.013,0.001,2630.2,0.059,0.07,0.003,44258.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-13",24,24,5977,,0.012,0.001,2431.7,0.059,0.064,0.003,40916,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-14",20,18.94,4583.28,,0.01,0.001,1907.436,0.059,0.073,0.0082,32101.226,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-15",24,24,5999,,0.012,0.001,2452.5,0.059,0.055,0.0026,41269.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-16",24,24,6272,,0.013,0.001,2568.7,0.059,0.069,0.0031,43223.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-17",24,24,6394,,0.013,0.001,2620.8,0.059,0.074,0.0033,44102.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-18",24,24,6201,,0.013,0.001,2541.5,0.059,0.071,0.0032,42763,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-19",24,24,5940,,0.012,0.001,2451.4,0.059,0.057,0.0027,41248.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-20",24,24,6622,,0.014,0.001,2706,0.059,0.079,0.0034,45536.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-21",24,24,6453,,0.013,0.001,2632,0.059,0.069,0.003,44285.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-22",24,24,6149,,0.013,0.001,2517.6,0.059,0.06,0.0028,42363.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-23",22,21.62,5236.16,,0.011,0.001,2180.468,0.059,0.076,0.0054,36692.476,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-24",24,24,6515,,0.014,0.001,2677.1,0.059,0.074,0.0032,45044.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-25",24,23.5,5882.5,,0.012,0.001,2416.65,0.059,0.06,0.0031,40664.05,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-27",20,19.92,4793.16,,0.01,0.001,2008.828,0.059,0.113,0.0143,33801.376,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-28",24,24,6361,,0.013,0.001,2610.8,0.059,0.066,0.0029,43928.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-29",24,24,6298,,0.013,0.001,2587.6,0.059,0.062,0.0028,43543.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-11-30",24,24,6528,,0.014,0.001,2689.4,0.059,0.076,0.0033,45252.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-01",24,24,6724,,0.014,0.001,2763.1,0.059,0.081,0.0034,46498.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-02",24,24,6727,,0.014,0.001,2768,0.059,0.082,0.0035,46579,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-03",24,24,6930,,0.014,0.001,2846.9,0.059,0.086,0.0035,47905,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-04",24,24,6968,,0.014,0.001,2859.7,0.059,0.087,0.0035,48121.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-05",24,24,6785,,0.014,0.001,2799.1,0.059,0.079,0.0033,47100.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-06",24,24,6645,,0.014,0.001,2736.8,0.059,0.077,0.0033,46050.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-07",24,24,6836,,0.014,0.001,2813.1,0.059,0.085,0.0035,47337.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-08",24,24,6697,,0.014,0.001,2749.9,0.059,0.082,0.0035,46271.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-09",24,24,6853,,0.014,0.001,2806.2,0.059,0.088,0.0037,47221.2,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-10",24,24,6789,,0.014,0.001,2785.5,0.059,0.083,0.0035,46874.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-11",24,24,6633,,0.014,0.001,2728.9,0.059,0.075,0.0032,45917,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-12",24,24,6612,,0.014,0.001,2714.1,0.059,0.073,0.0031,45666.7,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-13",24,24,6424,,0.013,0.001,2651,0.059,0.073,0.0032,44608.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-14",20,18.92,4668.56,,0.01,0.001,2034.05,0.059,0.089,0.0097,34229.954,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-15",24,24,6838,,0.015,0.001,2910.8,0.059,0.092,0.0038,48975.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-16",24,24,6698,,0.014,0.001,2831.3,0.059,0.085,0.0035,47645.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-17",24,24,6717,,0.014,0.001,2759.7,0.059,0.078,0.0033,46437.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-18",24,24,6406,,0.013,0.001,2647.1,0.059,0.068,0.0029,44545.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-19",24,24,6502,,0.014,0.001,2685.2,0.059,0.069,0.003,45180.9,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-20",24,24,6305,,0.013,0.001,2598.5,0.059,0.062,0.0027,43725.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-21",24,24,6570,,0.014,0.001,2702,0.059,0.073,0.0031,45461,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-22",24,24,6416,,0.013,0.001,2652.4,0.059,0.068,0.0029,44632.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-23",24,24,6713,,0.014,0.001,2757.9,0.059,0.077,0.0032,46403.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-24",24,24,6659,,0.014,0.001,2730.6,0.059,0.075,0.0032,45947.5,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-25",24,24,6438,,0.013,0.001,2629.9,0.059,0.067,0.003,44255.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-26",24,24,6294,,0.013,0.001,2586.7,0.059,0.066,0.0029,43529.1,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-27",24,24,6472,,0.013,0.001,2659.4,0.059,0.067,0.0029,44748.4,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-28",24,24,6756,,0.014,0.001,2776.4,0.059,0.079,0.0033,46713.3,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-29",24,24,6783,,0.014,0.001,2783.8,0.059,0.078,0.0033,46842.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-30",24,24,6693,,0.014,0.001,2745.5,0.059,0.077,0.0033,46198.8,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Colusa Generating Station",56532,"CT2",,"2020-12-31",24,24,6364,,0.013,0.001,2615.8,0.059,0.063,0.0028,44016.6,"Pipeline Natural Gas",,"Combined cycle",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-07",2,1.63,52.72,,0,0.001,30.992,0.059,0.003,0.0115,522.463,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-20",1,0.88,28.16,,0,0.001,16.72,0.059,0.002,0.016,281.16,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-21",11,9.95,327.95,,0.001,0.001,191.475,0.0592,0.007,0.005,3220.985,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-24",2,0.26,3.45,,0,0.001,2.698,0.059,0.001,0.0405,45.397,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-11",1,0.32,5.12,,0,0.001,3.712,0.06,0.001,0.027,62.304,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-12",5,3.98,159.28,,0,0.001,87.896,0.0594,0.004,0.0136,1479.364,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-13",10,7.66,309.26,,0.001,0.001,172.282,0.0592,0.011,0.0097,2900.131,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-14",2,1.08,38.92,,0,0.001,22.315,0.06,0.002,0.0115,374.76,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-18",5,2.73,83.87,,0,0.001,49.273,0.059,0.005,0.02,829.382,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-19",5,3.3,100.6,,0,0.001,59.744,0.0592,0.003,0.0162,1006.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-20",4,2.98,91.86,,0,0.001,54.237,0.0593,0.003,0.0093,912.222,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-21",5,4.03,136.34,,0,0.001,78.703,0.0592,0.004,0.0066,1325.15,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-22",6,5.22,197.36,,0.001,0.001,110.852,0.0595,0.005,0.0057,1864.104,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-23",7,5.42,184.77,,0.001,0.001,106.391,0.059,0.002,0.0059,1791.656,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-24",8,7.45,226.3,,0.001,0.001,132.275,0.059,0.006,0.0064,2230.545,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-25",8,5.88,186.97,,0.001,0.001,110.548,0.0593,0.006,0.013,1862.009,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-26",8,7.33,300.23,,0.001,0.001,166.272,0.0593,0.007,0.0074,2798.136,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-27",9,7.73,290.6,,0.001,0.001,163.321,0.0592,0.008,0.0073,2750.051,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-28",11,8.79,355.84,,0.001,0.001,198.311,0.0592,0.009,0.0077,3336.488,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-02-29",2,1.02,23,,0,0.001,15.114,0.0595,0.001,0.0215,253.934,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-04",5,4.78,192.17,,0.001,0.001,107.681,0.0592,0.006,0.0068,1811.822,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-08",7,6.26,273.84,,0.001,0.001,122.392,0.0596,0.007,0.0064,2060.414,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-09",8,6.47,209.12,,0.001,0.001,124.979,0.0593,0.006,0.0103,2102.072,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-10",4,2.22,85.35,,0,0.001,49.08,0.059,0.005,0.016,825.803,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-11",6,3.9,97.8,,0,0.001,53.248,0.0592,0.003,0.0098,895.912,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-12",9,5.5,210.58,,0.001,0.001,113.22,0.0593,0.008,0.0228,1907.27,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-13",6,3.41,147.22,,0.001,0.001,109.12,0.059,0.01,0.0152,1839.013,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-14",3,2.17,95.48,,0,0.001,69.44,0.059,0.005,0.0077,1170.281,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-15",4,2.9,133.4,,0,0.001,92.8,0.059,0.006,0.018,1563.97,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-16",5,2.88,102.78,,0,0.001,73.249,0.059,0.006,0.012,1233.877,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-17",5,3.18,134.7,,0,0.001,71.68,0.0592,0.003,0.0198,1205.33,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-18",4,2.96,92.99,,0,0.001,53.379,0.0598,0.003,0.0073,897.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-19",10,8.8,356.5,,0.001,0.001,194.1,0.0593,0.007,0.0084,3264.665,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-20",6,4.75,201.55,,0.001,0.001,109.15,0.0592,0.007,0.012,1836.375,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-24",2,1.28,43.16,,0,0.001,24.536,0.059,0.002,0.011,413.496,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-25",3,1.97,67.96,,0,0.001,38.219,0.0597,0.004,0.0157,642.729,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-28",2,1.85,74.15,,0,0.001,40.49,0.0595,0.003,0.0085,680.56,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-30",5,3.85,160.16,,0,0.001,86.175,0.059,0.006,0.0148,1451.026,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-02",7,5.7,247.82,,0.001,0.001,131.568,0.0593,0.017,0.0189,2214.73,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-03",4,2.95,123.75,,0,0.001,65.806,0.0593,0.009,0.0213,1107.025,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-04",3,2.06,84.6,,0,0.001,45.036,0.059,0.007,0.0223,758.548,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-07",4,3.03,125.4,,0,0.001,67.095,0.059,0.009,0.0315,1129.167,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-08",5,3.33,91.6,,0,0.001,54.801,0.0594,0.017,0.0398,921.451,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-09",4,2.32,92.2,,0,0.001,50.19,0.0593,0.008,0.036,844.842,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-10",3,1.98,73.15,,0,0.001,39.478,0.0597,0.006,0.0363,663.558,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-11",4,2.57,109.27,,0,0.001,58.292,0.0593,0.005,0.0275,980.625,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-14",5,4.33,118.04,,0,0.001,72.058,0.0596,0.004,0.0112,1210.728,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-15",3,1.57,46.15,,0,0.001,27.497,0.0597,0.003,0.0297,461.445,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-16",4,3.28,132.8,,0,0.001,71.923,0.059,0.004,0.0085,1211.779,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-17",6,3.87,113,,0,0.001,66.504,0.0592,0.006,0.0253,1119.994,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-18",5,3.82,155.72,,0,0.001,83.304,0.0596,0.004,0.0126,1400.522,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-19",5,3.25,123.24,,0,0.001,67.37,0.0592,0.003,0.0084,1133.78,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-21",3,2.02,88.68,,0,0.001,47.386,0.0593,0.003,0.01,797.026,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-23",7,5.9,274.8,,0.001,0.001,146.398,0.0591,0.006,0.0056,2463.28,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-24",9,7.5,349.76,,0.001,0.001,187.214,0.0592,0.009,0.0121,3149.502,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-25",7,5.4,213.78,,0.001,0.001,117.264,0.0596,0.006,0.0166,1972.672,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-26",4,3.8,144.8,,0,0.001,80.27,0.059,0.005,0.0075,1350.36,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-27",5,4.03,154,,0,0.001,85.36,0.059,0.005,0.0088,1437.126,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-28",6,4.4,200.6,,0.001,0.001,107.73,0.059,0.006,0.0145,1812.984,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-29",6,4.48,190.48,,0.001,0.001,103.928,0.0595,0.005,0.0167,1748.396,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-04-30",3,2.08,75.89,,0,0.001,42.351,0.0597,0.002,0.0303,711.596,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-01",3,2.52,93.42,,0,0.001,52.14,0.059,0.004,0.0097,877.542,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-02",2,1.38,55.49,,0,0.001,30.669,0.059,0.004,0.013,516.183,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-03",6,5,193,,0.001,0.001,106.608,0.059,0.006,0.0082,1793.88,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-04",6,5.05,209.26,,0.001,0.001,114.093,0.0592,0.006,0.0122,1919.802,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-05",7,5.85,229.8,,0.001,0.001,126.769,0.0594,0.007,0.0114,2132.376,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-06",8,6.2,287.04,,0.001,0.001,153.968,0.0593,0.007,0.015,2590.908,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-07",6,5.47,229.7,,0.001,0.001,125.109,0.0593,0.007,0.0072,2104.73,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-10",9,8.7,390,,0.001,0.001,208.68,0.0592,0.01,0.0061,3512.19,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-11",2,1.5,58.65,,0,0.001,32.18,0.059,0.003,0.0115,541.365,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-13",10,8.53,327.17,,0.001,0.001,182.642,0.0591,0.009,0.0091,3074.101,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-16",3,2.29,101.56,,0,0.001,54.799,0.059,0.004,0.0087,921.96,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-25",9,8.13,368.61,,0.001,0.001,199.765,0.0594,0.01,0.0066,3359.625,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-26",3,2.7,105.16,,0,0.001,58.904,0.059,0.004,0.008,991.47,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-29",7,5.47,206.46,,0.001,0.001,115.945,0.0593,0.006,0.012,1950.952,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-06",4,2.87,120.63,,0,0.001,65.152,0.059,0.004,0.021,1095.924,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-12",9,7.77,339.15,,0.001,0.001,183.018,0.0592,0.009,0.0082,3080.228,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-13",9,8.03,358.62,,0.001,0.001,194.492,0.059,0.009,0.0133,3272.925,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-14",7,6.05,269,,0.001,0.001,146.19,0.059,0.008,0.0117,2461.72,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-15",5,2.5,60.5,,0,0.001,38.238,0.0592,0.002,0.0198,644.682,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-17",9,8.25,373.75,,0.001,0.001,202.3,0.0593,0.009,0.0076,3402.425,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-18",3,2.33,101.94,,0,0.001,55.853,0.0593,0.004,0.0103,939.915,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-19",5,4.52,203.2,,0.001,0.001,109.952,0.0592,0.006,0.0068,1851.328,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-21",5,4.45,201.18,,0.001,0.001,109.255,0.0594,0.006,0.007,1838.411,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-22",10,9.1,434.6,,0.001,0.001,233.11,0.0593,0.011,0.0109,3920.98,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-23",10,9.26,245.39,,0.001,0.001,153.24,0.0593,0.006,0.0051,2578.378,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-24",15,14.95,612.25,,0.002,0.001,340.88,0.0593,0.016,0.0061,5733.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-25",16,14.37,565.61,,0.002,0.001,314.475,0.0593,0.014,0.0072,5292.447,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-28",6,4.68,190.44,,0.001,0.001,105.05,0.059,0.011,0.0217,1769.478,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-29",5,3.71,168.07,,0,0.001,91.436,0.0594,0.006,0.0148,1537.682,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-06-30",4,3.55,155.88,,0,0.001,85.418,0.0595,0.006,0.0085,1436.152,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-01",9,8.22,370.16,,0.001,0.001,199.896,0.059,0.01,0.0107,3365.26,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-02",10,9.27,405.75,,0.001,0.001,221.477,0.0592,0.01,0.0088,3726.68,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-03",13,12.38,561.58,,0.002,0.001,304.007,0.0592,0.015,0.006,5115.131,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-04",15,13.24,593.16,,0.002,0.001,322.54,0.059,0.016,0.0068,5428.344,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-05",9,6.39,152.08,,0.001,0.001,100.181,0.0596,0.007,0.0188,1684.541,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-06",5,4.03,89.86,,0,0.001,59.156,0.059,0.004,0.0092,996.442,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-08",1,0.03,0,,0,0.001,0.051,0.061,0,0.013,0.834,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-15",9,6.6,299,,0.001,0.001,162.095,0.0592,0.008,0.0107,2726.705,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-16",8,6.7,311.22,,0.001,0.001,168.148,0.0591,0.007,0.0058,2831.428,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-17",8,7.37,344.82,,0.001,0.001,185.813,0.0591,0.01,0.0066,3125.978,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-18",11,10.16,474.44,,0.001,0.001,258.358,0.0591,0.013,0.0077,4346.798,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-19",11,9.48,445.71,,0.001,0.001,241.014,0.0594,0.012,0.0093,4054.252,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-20",3,1.67,70.37,,0,0.001,38.859,0.06,0.003,0.0137,652.631,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-21",11,9.98,461.8,,0.001,0.001,250.344,0.0592,0.013,0.0073,4212.382,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-22",14,12.12,487.22,,0.001,0.0009,271.776,0.0591,0.018,0.0073,4573.646,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-24",6,4.77,206.73,,0.001,0.001,111.451,0.0595,0.007,0.0152,1874.239,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-25",9,7.28,319.7,,0.001,0.001,174.116,0.0594,0.009,0.0162,2928.02,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-26",10,10,455,,0.001,0.001,247,0.0591,0.012,0.006,4157.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-27",2,1.08,47.08,,0,0.001,25.696,0.059,0.001,0.0115,433.044,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-30",10,9.22,432.28,,0.001,0.001,234.562,0.0592,0.013,0.0072,3947.962,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-07-31",10,9.9,463.7,,0.001,0.001,252.25,0.0591,0.013,0.0061,4243.52,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-01",9,7.33,341.68,,0.001,0.001,184.669,0.0591,0.009,0.012,3109.294,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-04",8,7.19,335.43,,0.001,0.001,181.759,0.0593,0.009,0.0121,3058.918,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-05",6,5.14,236.64,,0.001,0.001,129.48,0.0595,0.008,0.0077,2177.318,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-06",6,4.35,199.68,,0.001,0.001,109.202,0.059,0.008,0.0193,1839.44,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-07",7,5.99,277.77,,0.001,0.001,151.82,0.0593,0.009,0.0091,2554.338,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-08",9,8.35,385.05,,0.001,0.001,210.705,0.0592,0.017,0.0126,3544.91,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-09",1,0.25,2.75,,0,0.001,2.5,0.059,0.002,0.081,42.05,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-10",9,8.75,403.5,,0.001,0.001,219.861,0.0593,0.013,0.0071,3698.356,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-11",8,6.9,315.8,,0.001,0.001,171.78,0.0594,0.01,0.01,2888.61,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-12",5,3.67,164.01,,0,0.001,89.522,0.0592,0.005,0.025,1506.622,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-14",13,12.95,616.8,,0.002,0.001,333.015,0.0592,0.016,0.006,5603.455,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-15",1,0.97,41.71,,0,0.001,22.989,0.059,0.001,0.006,386.545,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-17",14,12.39,548.95,,0.002,0.001,299.703,0.0592,0.014,0.01,5044.259,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-18",9,7.58,340.46,,0.001,0.001,187.232,0.0592,0.01,0.0152,3149.854,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-19",8,7.02,311.74,,0.001,0.001,170.052,0.0593,0.01,0.0144,2861.016,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-22",6,5.44,227.75,,0.001,0.001,125.537,0.0592,0.007,0.0088,2113.625,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-23",8,6.85,294.47,,0.001,0.001,161.364,0.059,0.008,0.0176,2717.596,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-28",6,4.85,216.61,,0.001,0.001,118.68,0.0593,0.007,0.008,1996.68,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-29",9,7.76,344.47,,0.001,0.001,188.966,0.0593,0.01,0.0081,3180.82,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-30",9,8.38,378.5,,0.001,0.001,206.566,0.0592,0.011,0.0069,3473.458,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-08-31",9,7.62,334.9,,0.001,0.001,183.991,0.0593,0.01,0.0114,3096.596,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-01",9,7.97,365.47,,0.001,0.001,200.49,0.0593,0.011,0.0083,3374.087,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-03",4,2.55,111.05,,0,0.001,61.871,0.0593,0.004,0.0158,1039.838,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-05",6,5.1,215.6,,0.001,0.001,119.54,0.0593,0.007,0.0162,2010.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-15",10,9.98,472.14,,0.001,0.001,257.128,0.0592,0.014,0.0067,4327.06,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-16",14,11.84,542.61,,0.002,0.001,297.662,0.0591,0.016,0.009,5009.36,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-17",9,8.25,334.61,,0.001,0.001,188.089,0.0591,0.012,0.0083,3165.226,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-18",14,13.11,570.72,,0.002,0.001,314.088,0.0593,0.028,0.0133,5284.327,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-19",12,11.45,537.65,,0.001,0.001,291.75,0.0593,0.014,0.0069,4910.285,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-20",11,10.21,469.97,,0.001,0.001,255.866,0.0594,0.013,0.0068,4305.504,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-21",11,9.42,439.95,,0.001,0.001,239.027,0.0591,0.012,0.0106,4023.892,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-23",10,8.7,310.6,,0.001,0.001,179.465,0.0594,0.012,0.0093,3019.365,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-24",9,7.28,333.25,,0.001,0.001,181.224,0.0593,0.009,0.0102,3049.029,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-25",6,5.43,249.75,,0.001,0.001,136.098,0.059,0.01,0.009,2291.718,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-26",5,4.07,182.26,,0.001,0.001,99.832,0.0592,0.007,0.0094,1679.532,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-27",9,8.58,397.68,,0.001,0.001,216.43,0.0593,0.011,0.0064,3639.316,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-28",11,9.85,461.97,,0.001,0.001,250.036,0.0592,0.012,0.0118,4209.036,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-09-30",5,2.19,82.03,,0,0.001,46.419,0.0592,0.006,0.0376,781.791,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-01",6,4.77,210.91,,0.001,0.001,114.459,0.0595,0.007,0.0247,1924.786,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-02",3,1.85,79.44,,0,0.001,43.596,0.0593,0.005,0.0203,734.438,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-03",4,2.65,118.35,,0,0.001,64.415,0.0595,0.004,0.029,1084.015,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-04",5,3.43,155.46,,0,0.001,84.231,0.059,0.006,0.024,1419.144,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-05",6,4.93,219.77,,0.001,0.001,118.842,0.0593,0.007,0.0127,1997.497,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-06",10,8.83,402.39,,0.001,0.001,217.828,0.059,0.011,0.0147,3667.417,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-07",6,5.16,232.52,,0.001,0.001,125.586,0.0592,0.008,0.0073,2115.454,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-08",3,2.75,123.25,,0,0.001,66.859,0.0593,0.005,0.0097,1124.837,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-09",3,2.32,103.12,,0,0.001,55.837,0.059,0.005,0.0103,939.87,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-10",4,3.71,169.75,,0,0.001,91.75,0.0593,0.006,0.0083,1544.005,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-11",6,5.73,270.29,,0.001,0.001,146.047,0.0593,0.009,0.0077,2455.584,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-12",7,6.14,282.65,,0.001,0.001,153.922,0.0593,0.01,0.0086,2589.929,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-13",3,1.93,83.7,,0,0.001,45.892,0.059,0.005,0.01,771.947,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-14",5,4.37,200.02,,0.001,0.001,108.665,0.059,0.007,0.008,1827.729,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-15",5,3.58,162.92,,0,0.001,88.715,0.0592,0.007,0.0166,1492.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-16",5,3.42,151.25,,0,0.001,82.371,0.0592,0.005,0.0134,1385.912,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-17",4,2.12,93,,0,0.001,51.016,0.0595,0.005,0.0215,857.065,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-18",7,6.5,306.72,,0.001,0.001,164.738,0.0591,0.009,0.007,2772.102,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-19",5,3.71,170.53,,0,0.001,91.526,0.059,0.006,0.011,1540.312,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-20",5,4.3,199.02,,0.001,0.001,107.526,0.059,0.007,0.0084,1809.968,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-21",15,13.4,627.72,,0.002,0.001,335.648,0.0591,0.017,0.0083,5646.664,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-22",2,0.93,27.48,,0,0.001,16.956,0.059,0.009,0.0645,285.538,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-23",15,13.4,522.7,,0.001,0.001,290.27,0.0593,0.013,0.0071,4882.11,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-24",12,10.17,422.9,,0.001,0.001,231.976,0.0593,0.01,0.0142,3905.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-27",1,0.02,0,,0,0.001,0.06,0.06,0,0.014,0.998,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-28",8,6.42,253.95,,0.001,0.001,139.865,0.0591,0.009,0.011,2355.209,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-30",9,7.66,357.2,,0.001,0.001,188.872,0.0592,0.011,0.013,3175.818,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-04",2,1.05,38.96,,0,0.001,21.926,0.0595,0.018,0.079,368.442,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-12",9,8.35,359.95,,0.001,0.001,191.6,0.0593,0.011,0.0106,3221.545,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-13",1,0.03,0,,0,0.001,0.168,0.059,0,0.076,2.841,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-16",4,3.51,152.4,,0,0.001,81.645,0.0593,0.007,0.0115,1373.86,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-07",4,3,133.26,,0,0.001,69.914,0.0593,0.007,0.0118,1176.592,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-10",3,1.31,40.38,,0,0.001,23.608,0.0593,0.004,0.0363,396.96,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-11",4,2.7,89.15,,0,0.001,51.75,0.0595,0.004,0.013,870.536,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-16",8,7.46,295.42,,0.001,0.001,161.99,0.0591,0.011,0.0094,2725.585,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-17",5,3.99,156.38,,0,0.001,84.857,0.0596,0.007,0.0102,1426.375,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-18",2,0.9,26.08,,0,0.001,15.447,0.0595,0.002,0.017,259.319,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-21",8,5.44,140.29,,0,0.001,86.726,0.059,0.014,0.0254,1461.12,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-22",6,3.87,120.76,,0,0.001,69.84,0.0598,0.009,0.0238,1173.615,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-24",3,2.07,88.02,,0,0.001,46.861,0.0597,0.003,0.0097,787.776,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-27",6,4.95,202.46,,0.001,0.001,109.426,0.0592,0.007,0.0087,1841.209,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-29",1,0.78,23.4,,0,0.001,13.416,0.059,0.003,0.03,226.278,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-05",2,0.8,22.6,,0,0.001,14.16,0.059,0.002,0.0255,238.12,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-11",7,5.32,113.72,,0,0.001,82.352,0.0594,0.007,0.0166,1383.576,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-13",1,0.38,6.46,,0,0.001,4.826,0.06,0.003,0.081,80.94,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-14",5,4.28,182.88,,0.001,0.001,102.836,0.0592,0.009,0.0122,1730.904,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-15",5,3.7,135.4,,0,0.001,78.608,0.0596,0.007,0.0262,1322.16,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-16",7,4.05,121.62,,0,0.001,75.144,0.0593,0.009,0.0251,1264.239,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-17",3,2.08,47.24,,0,0.001,32.69,0.0597,0.005,0.0517,550.018,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-20",8,7.08,275.49,,0.001,0.001,158.054,0.0594,0.011,0.0111,2658.472,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-22",1,0.27,3.24,,0,0.001,2.889,0.059,0.003,0.107,48.708,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-23",4,2.25,54.05,,0,0.001,37.365,0.0593,0.005,0.025,628.37,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-24",2,1.11,22.47,,0,0.001,16.484,0.0595,0.003,0.0285,277.505,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-26",5,3.01,100.62,,0,0.001,59.435,0.0592,0.009,0.0186,1000.056,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-28",7,4.51,116.16,,0,0.001,75.423,0.0593,0.009,0.0306,1269.357,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-30",5,2.44,53.08,,0,0.001,36.628,0.059,0.008,0.0328,617.036,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-03",10,8.37,265.35,,0.001,0.001,160.755,0.0595,0.012,0.0115,2703.724,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-04",3,2.51,62.87,,0,0.001,40.999,0.0593,0.007,0.0193,689.528,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-05",3,1.18,30.28,,0,0.001,19.806,0.059,0.009,0.0523,333.935,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-07",7,6.95,198.6,,0.001,0.001,123.535,0.0594,0.008,0.0079,2078.33,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-08",1,0.97,25.22,,0,0.001,16.199,0.059,0.001,0.008,272.473,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-09",2,1.46,51.1,,0,0.001,29.93,0.0595,0.005,0.02,503.335,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-10",5,3.53,125.5,,0,0.001,73.23,0.059,0.01,0.0156,1232.703,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-11",16,14.19,483.32,,0.001,0.001,287.105,0.0592,0.02,0.0193,4831.12,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-14",1,0.37,7.77,,0,0.001,5.365,0.06,0.003,0.069,90.095,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-27",11,8.19,325.17,,0.001,0.001,186.272,0.0592,0.012,0.0169,3135.064,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-28",12,9.29,364.27,,0.001,0.001,207.465,0.0596,0.016,0.0263,3487.928,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-02-29",3,1.87,53.64,,0,0.001,33.036,0.0597,0.005,0.022,555.393,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-01",5,3.5,134.28,,0,0.001,77.482,0.0594,0.007,0.0298,1303.192,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-02",8,7.12,185.18,,0.001,0.001,118.376,0.0595,0.009,0.0086,1990.74,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-03",4,3.43,108.43,,0,0.001,65.056,0.059,0.005,0.0143,1094.575,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-05",2,1.7,65.54,,0,0.001,37.436,0.0595,0.006,0.0195,629.916,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-06",5,4.27,190.39,,0.001,0.001,106.099,0.059,0.008,0.0102,1785.404,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-07",5,3.15,104.2,,0,0.001,62.395,0.0592,0.006,0.02,1049.65,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-08",6,4.42,184.96,,0.001,0.001,104.228,0.0592,0.007,0.0248,1754.017,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-09",10,9.28,293.6,,0.001,0.001,176.953,0.0593,0.014,0.0094,2975.52,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-10",18,15.67,550.24,,0.002,0.001,324.559,0.0593,0.019,0.0156,5457.579,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-11",24,24,675,,0.002,0.001,427.1,0.0593,0.017,0.0048,7189.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-12",16,15.82,523.68,,0.002,0.001,315.566,0.0592,0.011,0.0041,5308.408,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-13",13,10.09,408,,0.001,0.001,231.097,0.0592,0.017,0.0173,3889.271,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-14",14,11.33,425.03,,0.001,0.001,245.561,0.0595,0.017,0.0156,4128.199,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-15",8,6.22,269.85,,0.001,0.001,149.671,0.0593,0.008,0.0214,2517.251,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-16",12,9.49,290.91,,0.001,0.001,176.81,0.0593,0.016,0.0188,2976.555,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-18",3,1.83,68.09,,0,0.001,39.182,0.059,0.004,0.0173,659.193,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-19",7,5.32,218.66,,0.001,0.001,123.505,0.0591,0.013,0.0279,2079.472,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-20",4,2.19,89.84,,0,0.001,51.111,0.0595,0.005,0.0515,858.952,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-21",7,6.3,255.98,,0.001,0.001,145.38,0.0593,0.008,0.0077,2445.578,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-22",10,7.29,281.37,,0.001,0.001,161.11,0.0594,0.012,0.0211,2710.536,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-23",6,5.17,215.58,,0.001,0.001,121.614,0.059,0.007,0.0205,2046.486,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-24",6,4.9,211.12,,0.001,0.001,117.872,0.0595,0.007,0.0198,1983.24,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-25",5,3.15,132.5,,0,0.001,74.55,0.0594,0.006,0.042,1254.375,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-26",3,2.41,94.9,,0,0.001,54.066,0.059,0.006,0.02,910.527,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-27",4,2.85,105.52,,0,0.001,60.643,0.059,0.007,0.0215,1021.514,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-28",6,4.88,187.88,,0.001,0.001,107.794,0.0592,0.006,0.0135,1813.384,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-29",3,1.6,57.1,,0,0.001,33,0.0593,0.004,0.0213,555.91,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-30",7,5.1,216.07,,0.001,0.001,120.59,0.0594,0.008,0.0271,2028.19,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-03-31",4,2.3,64.75,,0,0.001,39.955,0.0595,0.005,0.0228,672.175,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-01",4,2.22,82.7,,0,0.001,47.123,0.0595,0.004,0.0393,792.814,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-02",5,3.82,163.8,,0,0.001,90.451,0.0594,0.006,0.025,1520.382,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-03",5,3.5,149,,0,0.001,82.4,0.0592,0.006,0.027,1385.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-04",7,5.42,233.89,,0.001,0.001,128.384,0.059,0.007,0.0163,2162.047,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-06",5,3.86,143.92,,0,0.001,81.944,0.0592,0.004,0.0094,1379.575,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-07",6,5.45,184.55,,0.001,0.001,107.665,0.0592,0.006,0.0095,1811.38,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-08",4,3.7,155.53,,0,0.001,86.492,0.059,0.007,0.0113,1456.358,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-09",5,3.6,145.72,,0,0.001,81.416,0.0592,0.007,0.0182,1370.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-10",4,3.23,135.08,,0,0.001,75.541,0.0595,0.008,0.0173,1270.256,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-11",9,6.27,250.82,,0.001,0.001,140.715,0.0592,0.012,0.024,2368.54,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-12",6,4.32,181.76,,0.001,0.001,101.056,0.059,0.007,0.0247,1702.66,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-13",7,6.57,210.8,,0.001,0.001,125.154,0.0593,0.009,0.0109,2105.266,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-14",8,6.15,248.03,,0.001,0.001,139.407,0.0595,0.009,0.0095,2343.483,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-15",5,4,178.2,,0,0.001,97.912,0.059,0.008,0.0192,1650.135,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-16",6,4.55,197.42,,0.001,0.001,109.735,0.0592,0.007,0.015,1847.089,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-17",7,5.28,217.48,,0.001,0.001,120.452,0.0591,0.007,0.0161,2028.754,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-20",5,4.11,179.15,,0.001,0.001,99.236,0.059,0.007,0.0276,1670.726,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-21",5,4.22,182.8,,0.001,0.001,101.6,0.0596,0.007,0.0102,1709.516,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-22",6,4.95,200.01,,0.001,0.001,112.678,0.0592,0.007,0.0172,1895.597,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-23",8,6.45,290.06,,0.001,0.001,158.822,0.0593,0.008,0.0196,2674.164,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-24",8,6.42,288.41,,0.001,0.001,158.517,0.0594,0.01,0.0216,2668.621,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-25",8,6.34,224.82,,0.001,0.001,130.528,0.0591,0.009,0.0146,2196.671,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-26",8,6.89,308.8,,0.001,0.001,170.549,0.0593,0.01,0.0175,2868.544,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-27",8,6.74,306.78,,0.001,0.001,167.452,0.0591,0.01,0.0131,2817.49,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-28",9,7.21,309.52,,0.001,0.001,171.551,0.0594,0.01,0.0277,2886.32,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-29",9,6.46,262.98,,0.001,0.001,147.891,0.0591,0.013,0.0256,2489.658,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-04-30",7,6.38,248.7,,0.001,0.001,141.025,0.0594,0.01,0.0093,2372.215,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-01",7,6.23,286.44,,0.001,0.001,156.133,0.0593,0.009,0.0163,2628.179,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-02",7,5.45,228.75,,0.001,0.001,126.925,0.0594,0.009,0.0127,2135.32,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-03",7,6.15,269.59,,0.001,0.001,148.864,0.0591,0.01,0.009,2505.578,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-04",11,9.9,434.1,,0.001,0.001,238.16,0.0595,0.013,0.0129,4005.61,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-05",9,8.6,385.58,,0.001,0.001,211.85,0.0594,0.013,0.0076,3563.059,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-06",6,6,243,,0.001,0.001,135.4,0.0593,0.009,0.0085,2277.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-07",10,7.73,308.93,,0.001,0.001,172.212,0.0592,0.01,0.0166,2899.052,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-10",5,4.37,173.85,,0,0.001,96.733,0.0592,0.009,0.012,1628.769,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-11",3,2.47,104.8,,0,0.001,58.422,0.059,0.006,0.0147,984.335,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-12",9,8.39,378.6,,0.001,0.001,208.413,0.0591,0.013,0.009,3508.816,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-14",5,4.33,190.57,,0.001,0.001,105.063,0.0596,0.009,0.0128,1766.222,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-15",7,5.59,252.23,,0.001,0.0009,138.08,0.0593,0.01,0.0074,2322.397,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-16",7,5.74,255.32,,0.001,0.001,140.39,0.0593,0.009,0.012,2362.881,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-17",8,7.25,324.12,,0.001,0.001,178.967,0.0594,0.011,0.0079,3010.388,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-18",4,2.73,116.2,,0,0.001,64.87,0.0593,0.006,0.014,1090.229,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-21",4,2.57,103.56,,0,0.001,58.216,0.059,0.005,0.0198,979.301,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-22",5,2.93,95.8,,0,0.001,56.205,0.0592,0.009,0.0214,946.125,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-25",5,4.33,104.6,,0,0.001,70.186,0.0592,0.005,0.0152,1180.269,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-26",2,1.06,28.17,,0,0.001,17.701,0.0595,0.003,0.0315,297.591,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-27",8,7.77,216.26,,0.001,0.001,139.686,0.0598,0.007,0.0056,2347.082,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-28",1,0.8,17.6,,0,0.001,12.48,0.059,0.001,0.008,210.08,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-01",1,0.8,27.2,,0,0.001,15.84,0.06,0.003,0.026,266.08,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-02",11,10.08,431.39,,0.001,0.001,241.045,0.0593,0.009,0.0056,4056.111,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-03",9,7.67,343.88,,0.001,0.001,190.177,0.0591,0.009,0.0098,3198.072,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-04",4,3.2,138.4,,0,0.001,77.088,0.0593,0.005,0.0163,1296.616,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-06",7,6.48,238.82,,0.001,0.001,139.756,0.0591,0.009,0.0083,2351.684,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-07",6,5.17,196.7,,0.001,0.001,114.046,0.0592,0.008,0.0102,1921.311,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-09",5,4.58,184.18,,0.001,0.001,104.242,0.0592,0.008,0.0108,1753.989,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-11",8,7.41,330.63,,0.001,0.001,182.674,0.0593,0.012,0.0084,3073.815,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-16",8,6.3,281.02,,0.001,0.001,156.658,0.0594,0.007,0.0213,2636.804,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-18",9,7.68,349.14,,0.001,0.001,192.586,0.0591,0.009,0.0162,3240.516,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-19",12,11.55,481.8,,0.001,0.001,268.995,0.0594,0.011,0.0062,4523.395,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-20",9,7.28,293.82,,0.001,0.001,164.893,0.0592,0.007,0.0087,2776.354,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-21",8,7.49,322.71,,0.001,0.001,179.984,0.0593,0.009,0.0064,3028.782,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-23",7,6.18,255.27,,0.001,0.001,143.028,0.0591,0.008,0.0081,2409.001,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-26",15,14.43,582.43,,0.002,0.001,330.037,0.0591,0.011,0.0092,5553.114,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-27",4,2.11,79.39,,0,0.001,46.126,0.0593,0.005,0.0365,775.63,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-28",9,7.4,329.96,,0.001,0.001,182.936,0.0593,0.008,0.011,3079.279,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-29",6,4.52,198.2,,0.001,0.001,111.065,0.0593,0.007,0.0162,1867.306,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-06-30",7,6.77,299.77,,0.001,0.001,167.138,0.0594,0.008,0.0067,2810.703,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-01",11,9.53,411.28,,0.001,0.001,229.678,0.059,0.012,0.0187,3865.879,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-02",9,8.25,339.38,,0.001,0.001,190.442,0.0591,0.009,0.007,3203.78,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-03",11,10.48,437.99,,0.001,0.001,245.285,0.0591,0.013,0.0066,4126.848,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-04",12,11.81,495.7,,0.001,0.001,276.754,0.0593,0.013,0.0057,4655.841,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-05",10,9.38,418.33,,0.001,0.001,231.445,0.0592,0.012,0.0074,3893.485,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-06",8,7.23,318.21,,0.001,0.001,176.918,0.0591,0.013,0.0175,2976.093,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-07",6,3.97,153.58,,0,0.001,88.208,0.0597,0.006,0.0112,1482.162,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-08",4,3.63,157.2,,0,0.001,87.771,0.0595,0.006,0.0105,1475.435,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-09",7,5.92,262.68,,0.001,0.001,146.032,0.059,0.007,0.0107,2457.168,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-10",7,5.51,246.1,,0.001,0.001,136.071,0.0591,0.007,0.0124,2291.091,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-11",8,7.04,269.96,,0.001,0.001,156.505,0.0591,0.008,0.01,2634.426,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-12",11,8.68,371.63,,0.001,0.001,206.941,0.0591,0.012,0.0105,3483.847,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-13",9,7.32,327.78,,0.001,0.001,180.856,0.0592,0.008,0.016,3043.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-14",8,6.27,279.43,,0.001,0.001,154.314,0.059,0.007,0.019,2597.759,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-15",5,3.25,136.5,,0,0.001,76.494,0.0594,0.006,0.0118,1286.078,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-18",10,8.51,380.61,,0.001,0.001,210.728,0.0592,0.01,0.0132,3548.245,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-19",5,4.28,188.2,,0.001,0.001,104.356,0.0594,0.007,0.011,1753.848,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-20",10,8.6,381.8,,0.001,0.001,212.576,0.0594,0.011,0.0095,3574.216,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-21",6,4.88,207.45,,0.001,0.001,116.803,0.0595,0.006,0.0123,1964.801,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-22",7,6.04,252.8,,0.001,0.001,141.936,0.0593,0.007,0.0076,2386.124,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-24",6,4.66,205.36,,0.001,0.001,113.39,0.059,0.007,0.0198,1909.376,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-25",13,11.68,518,,0.001,0.001,287.454,0.0594,0.016,0.0077,4833.391,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-26",12,11.3,494,,0.001,0.001,274.89,0.0592,0.013,0.0088,4627.63,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-27",12,10.6,464.96,,0.001,0.001,258.075,0.0595,0.009,0.0103,4341.874,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-28",10,9.03,406.83,,0.001,0.001,225.182,0.0591,0.01,0.015,3791.45,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-29",9,8.05,359.2,,0.001,0.001,198.627,0.0591,0.007,0.0086,3343.565,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-02",8,7.87,353.62,,0.001,0.001,195.374,0.059,0.009,0.0055,3287.382,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-03",12,11.07,499.56,,0.001,0.001,276.231,0.0593,0.011,0.006,4648.435,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-05",8,7.43,333.95,,0.001,0.001,185.497,0.0595,0.009,0.007,3118.896,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-06",7,5.97,234.9,,0.001,0.001,135.514,0.0591,0.009,0.0091,2281.365,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-07",11,10.28,472.68,,0.001,0.001,260.936,0.0592,0.012,0.0105,4390.328,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-08",12,10.45,464.78,,0.001,0.001,258.037,0.0593,0.012,0.0113,4341.926,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-09",10,9.55,433.8,,0.001,0.001,238.795,0.0592,0.012,0.0064,4020.67,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-10",11,10.92,494.72,,0.001,0.001,272.644,0.0592,0.013,0.0057,4587.412,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-11",11,8.88,390.39,,0.001,0.001,217.077,0.0595,0.01,0.0127,3650.488,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-12",14,13.14,591.61,,0.002,0.001,327.145,0.0591,0.014,0.0056,5505.687,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-13",15,13.64,618.15,,0.002,0.001,341.714,0.0591,0.015,0.011,5751.866,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-15",13,12.17,555.23,,0.002,0.001,304.844,0.0592,0.011,0.011,5130.389,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-16",14,13.18,596.02,,0.002,0.001,328.12,0.0591,0.012,0.005,5519.922,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-17",1,0.22,5.72,,0,0.001,3.762,0.06,0,0.007,63.206,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-18",12,11.82,524.62,,0.001,0.001,290.56,0.0593,0.013,0.0055,4889.158,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-19",8,7.45,318.1,,0.001,0.001,177.113,0.0593,0.01,0.0069,2978.57,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-20",8,7,309.58,,0.001,0.001,171.18,0.0593,0.007,0.0088,2880.722,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-21",11,10.26,452.08,,0.001,0.001,250.502,0.0593,0.01,0.007,4214.602,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-22",8,6.7,250.57,,0.001,0.001,143.079,0.0593,0.006,0.0164,2407.491,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-23",5,4.82,175.75,,0.001,0.001,100.661,0.059,0.006,0.0068,1694.433,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-24",12,10.83,488.65,,0.001,0.001,268.643,0.0591,0.01,0.0097,4519.985,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-25",11,10.2,459.55,,0.001,0.001,253.84,0.0593,0.012,0.0091,4268.92,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-26",7,6.6,294.87,,0.001,0.001,162.668,0.059,0.009,0.0069,2737.469,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-27",10,9.13,410.91,,0.001,0.001,226.927,0.0594,0.011,0.015,3816.977,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-28",9,8.14,351.79,,0.001,0.001,196.329,0.0592,0.011,0.0073,3304.28,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-29",11,10.55,456.77,,0.001,0.001,255.295,0.0592,0.011,0.0055,4295.961,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-30",13,12.08,535.16,,0.001,0.001,295.748,0.0592,0.01,0.0078,4977.98,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-08-31",13,12.17,521.97,,0.001,0.001,292.543,0.0592,0.011,0.0058,4921.563,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-01",10,9.05,401,,0.001,0.001,224.515,0.0591,0.009,0.0078,3777.355,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-02",5,3.27,135.42,,0,0.001,76.865,0.0594,0.006,0.0106,1293.014,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-03",9,8.48,377.46,,0.001,0.001,210.402,0.059,0.009,0.0051,3542.71,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-04",13,11.92,528.62,,0.001,0.001,293.714,0.059,0.011,0.0087,4946.254,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-05",11,9.33,396.06,,0.001,0.001,223.24,0.0592,0.011,0.0145,3756.876,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-06",9,7.22,322,,0.001,0.0009,178.664,0.0593,0.014,0.0212,3004.544,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-10",6,4.58,165.15,,0,0.001,95.47,0.0595,0.007,0.0107,1604.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-13",4,3.07,131.67,,0,0.001,73.943,0.059,0.008,0.0155,1243.812,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-14",10,9.55,430.15,,0.001,0.001,240.04,0.0592,0.012,0.0062,4038.71,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-15",7,6.05,222.92,,0.001,0.001,132.099,0.059,0.009,0.0091,2223.595,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-16",12,11.55,482.95,,0.001,0.001,271.9,0.0591,0.014,0.0078,4575.695,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-17",14,11.48,508.92,,0.001,0.001,283.026,0.0591,0.017,0.009,4762.53,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-18",11,10.42,446.7,,0.001,0.001,250.068,0.0593,0.014,0.0095,4205.718,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-19",15,13.43,598.92,,0.002,0.001,332.949,0.0593,0.015,0.0077,5603.947,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-20",16,14.25,638.16,,0.002,0.001,353.471,0.0593,0.015,0.0116,5949.282,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-21",14,11.7,519.91,,0.001,0.001,288.9,0.0593,0.013,0.007,4860.85,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-22",12,10.18,459.69,,0.001,0.001,255.188,0.0593,0.012,0.0159,4296.676,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-23",13,11.43,513.96,,0.001,0.001,285.619,0.0593,0.014,0.012,4805.643,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-24",9,7.78,317.73,,0.001,0.001,180.147,0.0592,0.011,0.0143,3031.413,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-25",9,7.93,354.88,,0.001,0.001,196.427,0.0591,0.012,0.0173,3305.825,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-26",6,5.12,223.94,,0.001,0.001,124.936,0.0592,0.009,0.009,2101.358,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-27",11,9.13,407.6,,0.001,0.001,226.666,0.0596,0.012,0.0171,3811.195,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-28",13,11.91,517.04,,0.001,0.001,288.414,0.0592,0.015,0.0121,4854.645,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-09-30",7,6.15,273.79,,0.001,0.001,152.254,0.0591,0.01,0.0101,2561.882,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-01",6,4.33,183.33,,0.001,0.001,102.571,0.059,0.007,0.0203,1726.61,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-02",4,3.18,136.4,,0,0.001,75.812,0.0593,0.007,0.0113,1275.162,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-03",9,8.06,329.96,,0.001,0.001,185.882,0.0592,0.01,0.0156,3127.302,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-04",10,8.19,367.96,,0.001,0.001,203.324,0.0594,0.012,0.0105,3419.532,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-05",6,5.49,244.48,,0.001,0.001,135.868,0.059,0.009,0.0088,2288.065,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-06",13,11.3,497.25,,0.001,0.001,277.112,0.0592,0.014,0.0173,4661.856,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-07",10,9.06,403.88,,0.001,0.001,224.26,0.059,0.012,0.007,3774.434,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-08",8,6.38,280.09,,0.001,0.001,155.888,0.0591,0.009,0.0114,2623.14,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-09",5,4.08,179.06,,0.001,0.001,99.091,0.0596,0.007,0.0204,1666.429,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-10",9,7.88,322.24,,0.001,0.001,182.512,0.0591,0.01,0.0107,3072.356,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-11",8,7.28,326.61,,0.001,0.001,181.208,0.0594,0.011,0.0111,3047.181,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-12",8,7.35,320.55,,0.001,0.001,179.665,0.0593,0.01,0.0069,3022.94,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-13",7,6.28,280.68,,0.001,0.001,156.476,0.059,0.01,0.0074,2633.356,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-14",10,8.23,370.6,,0.001,0.001,205.317,0.0593,0.011,0.0158,3454.561,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-15",11,10.02,451.98,,0.001,0.001,250.738,0.0594,0.013,0.0142,4218.522,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-16",10,9.72,362.08,,0.001,0.001,209.712,0.0591,0.01,0.006,3527.836,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-17",11,9.65,347.27,,0.001,0.001,202.485,0.0591,0.011,0.0081,3409.312,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-18",18,16.83,609.1,,0.002,0.001,353.405,0.0592,0.017,0.0074,5949.478,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-19",8,7.23,255.37,,0.001,0.001,148.474,0.0594,0.007,0.0061,2497.891,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-20",13,9.86,416.1,,0.001,0.001,233.105,0.0592,0.02,0.0298,3922.083,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-21",5,3.45,149.52,,0,0.001,83.621,0.0594,0.006,0.0142,1405.745,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-22",3,2.17,90.97,,0,0.001,51.354,0.0593,0.006,0.0133,864.25,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-23",2,0.96,27.68,,0,0.001,17.042,0.0595,0.003,0.0525,287.026,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-26",10,9.3,344.4,,0.001,0.001,199.399,0.0591,0.012,0.0084,3357.883,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-27",12,10.14,354.99,,0.001,0.001,208.634,0.0594,0.009,0.0097,3508.332,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-28",3,2.05,52.7,,0,0.001,34.165,0.0593,0.007,0.0213,574.785,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-04",5,3.6,160.59,,0,0.001,89.237,0.0592,0.004,0.007,1500.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-05",9,7.55,345.4,,0.001,0.001,189.77,0.0592,0.01,0.0151,3191.625,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-06",7,4.88,210.35,,0.001,0.001,116.407,0.0591,0.011,0.0239,1959.654,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-08",4,3.24,137.5,,0,0.001,76.56,0.059,0.006,0.0105,1288.244,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-09",7,6.82,315.62,,0.001,0.001,173.624,0.0593,0.011,0.0084,2921.856,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-10",9,8.8,394.24,,0.001,0.001,217.284,0.059,0.023,0.0152,3657.152,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-11",8,6.29,275.2,,0.001,0.001,152.852,0.0595,0.01,0.0198,2570.727,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-13",5,4.92,214.64,,0.001,0.001,119.604,0.059,0.01,0.0102,2012.22,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-15",6,5.08,234.16,,0.001,0.001,128.332,0.0593,0.009,0.0155,2158.524,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-17",3,2.12,90.45,,0,0.001,50.505,0.059,0.006,0.014,849.816,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-18",6,5.02,227.2,,0.001,0.001,126.156,0.0592,0.008,0.0092,2123.262,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-19",5,4.13,182.16,,0.001,0.001,100.922,0.0592,0.008,0.0094,1698.08,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-20",9,8.03,357.81,,0.001,0.001,199.263,0.0592,0.012,0.008,3352.516,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-21",9,7.98,366.03,,0.001,0.001,201.66,0.0592,0.011,0.0167,3394.004,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-22",9,8.27,374.93,,0.001,0.001,206.968,0.0591,0.012,0.0074,3483.468,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-23",7,5.35,240.31,,0.001,0.001,133.144,0.0591,0.009,0.0143,2241.626,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-24",4,2.95,124.94,,0,0.001,69.897,0.0593,0.005,0.0258,1175.057,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-25",3,1.66,67.22,,0,0.001,38.174,0.0593,0.005,0.0303,641.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-28",6,4.88,214.28,,0.001,0.001,119.226,0.0593,0.009,0.0097,2005.312,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-29",7,5.4,239.5,,0.001,0.001,133.407,0.0591,0.009,0.0196,2245.806,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-11-30",8,6.9,311.18,,0.001,0.001,172.656,0.0591,0.011,0.0083,2905.034,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-02",8,6.41,281.09,,0.001,0.001,158.144,0.0591,0.011,0.0194,2661.033,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-04",7,5.69,253.14,,0.001,0.001,141.105,0.0591,0.009,0.0123,2375.502,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-05",6,5.03,193.83,,0.001,0.001,111.353,0.0592,0.009,0.0105,1874.323,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-07",5,4.67,163.69,,0,0.001,96.524,0.0592,0.008,0.0104,1623.844,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-08",6,4.72,117.69,,0,0.001,78.165,0.059,0.009,0.015,1317.104,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-09",4,3.35,86.58,,0,0.001,56.933,0.0593,0.006,0.0158,958.811,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-10",7,6.05,138.55,,0,0.001,92.818,0.0594,0.019,0.0249,1561.343,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-11",4,2.19,61.73,,0,0.001,39.12,0.0593,0.004,0.0128,657.989,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-12",10,8.2,329.6,,0.001,0.001,186.696,0.0592,0.009,0.0053,3143.136,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-13",8,6.36,280.77,,0.001,0.001,156.638,0.059,0.009,0.0171,2635.699,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-18",3,2.15,63.35,,0,0.001,38.975,0.059,0.005,0.0307,655.965,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-21",2,1.14,32.79,,0,0.001,20.327,0.0595,0.003,0.0255,341.596,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-27",4,2.93,103.35,,0,0.001,59.719,0.0593,0.007,0.0143,1005.344,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-29",1,0.85,29.75,,0,0.001,17.425,0.059,0.005,0.031,293.675,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Niland Gas Turbine Plant",56569,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-13",3,2.05,91.26,,0,0.001,60.991,0.059,0.009,0.026,1025.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-10",1,0.62,27.28,,0,0.001,19.158,0.059,0.008,0.051,322.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-12",1,0.48,19.68,,0,0.001,14.016,0.059,0.008,0.07,235.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-14",7,5.75,279.49,,0.001,0.001,184.232,0.0593,0.021,0.0167,3098.922,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-21",4,3.03,145.8,,0,0.001,95.484,0.059,0.01,0.0205,1607.821,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-22",3,2.56,116.8,,0,0.001,77.836,0.0593,0.01,0.0147,1308.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-01",4,2.55,120.9,,0,0.001,80.525,0.0595,0.009,0.0255,1355.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-21",3,2.05,96.76,,0,0.001,64.14,0.059,0.01,0.0197,1079.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-23",2,1.31,53.79,,0,0.001,37.215,0.059,0.01,0.0245,625.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-25",3,2.56,123.2,,0,0.001,81.154,0.059,0.013,0.024,1366.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-26",3,2.81,132.54,,0,0.001,88.855,0.059,0.012,0.0163,1495.463,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-27",3,2.83,132.39,,0,0.001,88.304,0.059,0.013,0.0173,1486.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-03",3,2.33,111.23,,0,0.001,72.657,0.0593,0.011,0.0167,1221.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-04",3,1.75,76.03,,0,0.001,50.979,0.059,0.008,0.0313,859.091,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-09",4,3.31,163.23,,0.001,0.001,105.706,0.0595,0.014,0.0193,1776.634,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-10",5,4.01,202.56,,0.001,0.001,130.963,0.059,0.014,0.0154,2203.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-06-30",3,2.54,123.38,,0,0.001,80.714,0.059,0.011,0.0197,1358.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-04",3,2.06,91.71,,0,0.001,61.133,0.059,0.01,0.021,1029.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-23",4,3.23,111.76,,0,0.001,80.981,0.0593,0.009,0.0138,1363.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-30",3,2.05,91,,0,0.001,59.87,0.0593,0.014,0.0327,1007.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-09",3,2.31,103.88,,0,0.001,70.232,0.059,0.011,0.03,1181.191,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-10",2,1.33,55.46,,0,0.001,38.172,0.059,0.008,0.038,642.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-12",3,2.56,117.08,,0,0.001,78.297,0.0593,0.011,0.021,1317.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-13",12,10.81,541.59,,0.002,0.001,354.116,0.0592,0.03,0.0116,5959.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-14",10,9.95,516.55,,0.002,0.001,336.135,0.0591,0.03,0.0108,5656.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-15",11,9.24,455.78,,0.002,0.001,299.584,0.0591,0.025,0.01,5041.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-16",7,6.8,318.81,,0.001,0.001,212.002,0.0591,0.021,0.0121,3566.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-17",14,13.08,670.56,,0.002,0.001,436.98,0.0592,0.034,0.0096,7349.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-18",15,13.5,664.29,,0.002,0.001,438.527,0.0592,0.04,0.0114,7377.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-19",6,4.26,213.72,,0.001,0.001,139.624,0.0592,0.018,0.0245,2350.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-22",6,5.32,257.24,,0.001,0.001,170.056,0.0593,0.018,0.0192,2860.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-24",5,4.57,217.53,,0.001,0.001,144.182,0.059,0.016,0.0134,2426.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-28",2,0.95,40.44,,0,0.001,28.362,0.0595,0.011,0.0275,476.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-04",2,1.31,58.6,,0,0.001,39.794,0.059,0.009,0.0215,669.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-05",4,3.33,156.8,,0.001,0.001,104.577,0.0593,0.014,0.018,1759.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-06",7,6.07,298.58,,0.001,0.001,195.685,0.0593,0.018,0.0133,3291.222,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-07",3,1.85,82.6,,0,0.001,55.565,0.0593,0.01,0.0223,935.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-11",2,1.45,64.75,,0,0.001,43.745,0.059,0.013,0.0255,735.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-19",4,3.82,187.95,,0.001,0.001,123.315,0.059,0.016,0.016,2076.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-24",2,1.55,64,,0,0.001,44.235,0.0595,0.011,0.023,744.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-28",3,2.6,107.2,,0,0.001,72.488,0.059,0.012,0.0183,1220.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-29",3,1.33,55.31,,0,0.001,37.932,0.0593,0.01,0.069,637.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-02",2,1.38,59.83,,0,0.001,41.159,0.0595,0.012,0.035,692.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-03",3,1.82,81.06,,0,0.001,55.276,0.0597,0.012,0.024,929.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-07",2,0.85,15.77,,0,0.0005,11.496,0.0595,0.004,0.02,192.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-09",2,0.88,36.52,,0,0.001,25.847,0.0595,0.013,0.0335,435.101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-12",2,0.88,37.44,,0,0.001,26.238,0.0595,0.01,0.024,441.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-21",3,1.5,66.28,,0,0.001,45.066,0.0593,0.012,0.046,757.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-23",2,1.28,52.44,,0,0.001,37.007,0.0595,0.013,0.0305,622.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-27",6,3.97,188.48,,0.001,0.0008,125.834,0.0592,0.023,0.0235,2117.867,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-02",4,3.31,159.55,,0.001,0.001,104.875,0.059,0.014,0.0195,1765.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-03",3,2.86,131.84,,0,0.001,88.128,0.0593,0.013,0.017,1483.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-04",6,5.58,278.45,,0.001,0.001,182.243,0.0592,0.017,0.0135,3066.547,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-05",6,5.31,260.86,,0.001,0.001,171.336,0.0592,0.016,0.011,2884.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-06",4,3.08,145.22,,0,0.001,96.046,0.059,0.018,0.026,1615.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-08",2,1.78,79.94,,0,0.001,53.681,0.0595,0.008,0.0185,902.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-12",3,1.65,71.06,,0,0.001,48.017,0.0597,0.01,0.032,807.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-13",2,1.6,69.52,,0,0.001,47.316,0.059,0.007,0.016,796.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-15",4,3.03,151.28,,0,0.001,98.55,0.0593,0.015,0.036,1657.566,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-16",4,3.08,120.7,,0,0.001,87.617,0.0593,0.012,0.017,1474.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-17",3,1.8,79.64,,0,0.001,53.676,0.059,0.011,0.0223,904.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-20",2,1.33,56.02,,0,0.001,38.365,0.0595,0.009,0.0205,645.371,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-21",3,2.33,107.48,,0,0.001,71.513,0.059,0.014,0.0253,1204.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-22",3,1.85,82.64,,0,0.001,55.734,0.059,0.011,0.0223,937.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-24",4,3.35,158.68,,0.001,0.001,105.565,0.0593,0.014,0.019,1775.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-25",3,2.6,120.28,,0,0.001,80.604,0.0597,0.011,0.0157,1355.636,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-29",4,3.33,158.48,,0.001,0.001,104.82,0.059,0.011,0.0148,1764.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-11-30",5,4.39,211.33,,0.001,0.001,139.98,0.059,0.015,0.0144,2356.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-01",8,6.91,337.02,,0.001,0.001,220.175,0.0591,0.024,0.0143,3705.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-02",5,4.33,217.43,,0.001,0.001,140.955,0.0592,0.016,0.0152,2370.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-03",7,5.65,274.65,,0.001,0.001,180.732,0.0593,0.02,0.0149,3039.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-04",10,8.86,451.97,,0.001,0.001,293.545,0.059,0.031,0.017,4940.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-05",6,5.58,273.28,,0.001,0.001,178.556,0.059,0.018,0.0123,3003.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-06",5,4.1,201.82,,0.001,0.001,133.192,0.059,0.015,0.015,2242.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-07",1,0.85,30.6,,0,0.001,22.525,0.059,0.009,0.045,379.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-08",4,3.33,121.5,,0,0.001,89.854,0.0593,0.015,0.0203,1511.899,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-09",7,5.77,272.39,,0.001,0.001,179.272,0.059,0.018,0.0136,3016.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-10",9,8.39,414.68,,0.001,0.001,271.081,0.0591,0.029,0.013,4560.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-11",10,8.95,468.82,,0.002,0.001,304.088,0.059,0.03,0.0129,5116.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-12",8,7.33,393.82,,0.001,0.001,253.378,0.059,0.022,0.0106,4263.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-13",7,5.55,285.11,,0.001,0.001,185.868,0.0591,0.018,0.015,3128.459,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-14",9,7.78,374.75,,0.001,0.001,246.193,0.059,0.02,0.013,4142.637,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-15",10,8.61,426.38,,0.001,0.001,278.377,0.059,0.027,0.0163,4685.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-16",12,10.42,550.98,,0.002,0.001,355.145,0.059,0.033,0.0118,5975.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-18",6,5.58,271.6,,0.001,0.001,178.07,0.0593,0.019,0.013,2994.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-19",4,2.83,119.74,,0,0.001,82.22,0.0593,0.02,0.0283,1383.381,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-20",3,1.32,56.02,,0,0.001,37.873,0.0593,0.008,0.0523,636.791,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-23",2,1.33,56.92,,0,0.001,38.725,0.059,0.009,0.0215,651.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-25",2,1.31,55.6,,0,0.001,38.026,0.059,0.008,0.0235,639.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-27",5,4.31,208.6,,0.001,0.001,136.827,0.059,0.014,0.0148,2303.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"1",,"2020-12-31",2,1.33,56.02,,0,0.001,38.541,0.0595,0.008,0.019,648.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-13",3,2.05,90.15,,0,0.001,60.957,0.059,0.009,0.0257,1025.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-10",2,1.26,54.18,,0,0.001,38.116,0.059,0.008,0.0255,641.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-12",2,1.3,54.6,,0,0.001,37.84,0.0595,0.008,0.0275,635.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-14",7,5.75,285.49,,0.001,0.001,188.55,0.0594,0.019,0.0136,3172.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-21",4,3.08,153.08,,0.001,0.001,100.988,0.0595,0.008,0.0138,1699.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-22",3,2.51,117.06,,0,0.001,78.045,0.0593,0.008,0.0127,1312.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-02",2,1.61,62.62,,0,0.001,45.311,0.0595,0.008,0.0205,762.194,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-21",2,0.69,12.4,,0,0.0005,12.547,0.059,0.006,0.033,210.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-23",2,1.31,52.91,,0,0.001,37.299,0.059,0.011,0.0295,627.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-25",3,2.56,119.64,,0,0.001,80.379,0.059,0.017,0.031,1353.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-26",3,2.8,126.34,,0,0.001,87.138,0.059,0.012,0.0163,1465.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-27",3,2.83,132.39,,0,0.001,88.707,0.059,0.013,0.0177,1492.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-03",3,2.33,104.9,,0,0.001,70.868,0.059,0.009,0.0137,1193.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-04",3,1.75,76.03,,0,0.001,51.547,0.0593,0.007,0.024,867.789,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-09",4,3.31,160.97,,0.001,0.001,106.673,0.0595,0.011,0.0148,1793.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-10",5,4.06,202.91,,0.001,0.001,134.155,0.0592,0.013,0.0122,2256.967,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-06-30",3,2.54,125.92,,0,0.001,82.742,0.059,0.009,0.0153,1392.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-04",3,2.06,92.34,,0,0.001,61.963,0.0593,0.009,0.018,1041.779,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-23",4,3.21,111.53,,0,0.001,81.306,0.0593,0.009,0.0133,1368.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-30",3,2.05,83,,0,0.001,60.065,0.0593,0.014,0.032,1010.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-09",3,2.31,103.88,,0,0.001,70.542,0.059,0.01,0.0267,1186.867,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-10",2,1.33,54.66,,0,0.001,38.278,0.059,0.007,0.0315,644.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-12",3,2.55,116.34,,0,0.001,78.532,0.059,0.009,0.0173,1322.669,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-13",12,10.81,532.22,,0.002,0.001,351.641,0.0591,0.03,0.0113,5916.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-14",10,9.95,511.55,,0.002,0.001,336.315,0.059,0.028,0.0101,5660.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-15",11,9.23,446,,0.001,0.001,296.504,0.0591,0.021,0.0085,4988.681,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-16",5,4.7,162.44,,0.001,0.001,117.096,0.0594,0.012,0.0126,1970.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-17",14,13.06,516.66,,0.002,0.001,358.836,0.0591,0.028,0.0096,6040.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-18",15,13.47,493.08,,0.002,0.001,350.011,0.0593,0.03,0.0105,5886.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-19",6,4.21,102.4,,0,0.001,81.283,0.0595,0.011,0.0245,1366.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-20",1,0.15,0,,0,0.001,0.45,0.06,0,0.069,7.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-24",5,4.57,112.9,,0,0.001,80.025,0.0594,0.007,0.0096,1346.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-25",4,0.45,0,,0,0.001,1.817,0.0593,0.001,0.045,30.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-28",2,0.95,40.44,,0,0.001,28.401,0.059,0.022,0.049,478.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-04",2,1.33,58.42,,0,0.001,40.462,0.059,0.008,0.018,681.173,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-05",4,3.33,156.8,,0.001,0.001,105.813,0.0593,0.012,0.015,1780.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-06",7,6.07,295.51,,0.001,0.001,197.085,0.0591,0.018,0.0126,3316.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-07",3,1.83,82.23,,0,0.001,56.309,0.059,0.009,0.0177,946.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-11",5,2.78,120.58,,0,0.001,82.932,0.0592,0.024,0.0478,1394.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-19",4,3.82,184.18,,0.001,0.001,122.75,0.0593,0.013,0.0138,2065.067,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-28",3,2.62,117,,0,0.001,79.222,0.059,0.014,0.0193,1333.742,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-29",3,1.33,55.46,,0,0.001,38.211,0.059,0.009,0.066,642.501,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-02",2,1.36,59.54,,0,0.001,41.303,0.0595,0.011,0.0325,694.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-03",3,1.8,68.78,,0,0.001,49.368,0.0593,0.01,0.0223,829.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-07",1,0.4,8.4,,0,0.001,7.24,0.06,0.008,0.13,121.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-09",1,0.35,3.5,,0,0.001,3.08,0.059,0.005,0.185,51.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-12",2,0.83,17.94,,0,0.001,12.819,0.0585,0.006,0.032,215.603,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-21",3,1.52,65.84,,0,0.001,45.78,0.0593,0.014,0.0517,770.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-23",2,1.33,55.59,,0,0.001,39.081,0.059,0.013,0.029,657.699,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-27",6,3.97,185.72,,0.001,0.0008,126.106,0.0593,0.023,0.022,2121.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-02",4,2.72,100.04,,0,0.001,71.092,0.0598,0.009,0.036,1195.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-03",3,2.85,132.3,,0,0.001,89.137,0.059,0.012,0.0167,1501.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-04",6,5.58,273.59,,0.001,0.001,182.364,0.059,0.017,0.0132,3068.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-05",3,0.8,4.2,,0,0.001,5.785,0.0593,0.009,0.139,97.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-06",4,3.08,144,,0,0.001,97.034,0.059,0.017,0.0235,1632.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-08",2,1.83,76.02,,0,0.001,54.609,0.059,0.011,0.0235,918.297,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-12",1,0.13,0,,0,0.001,0.507,0.059,0,0.052,8.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-13",2,1.6,67.92,,0,0.001,47.248,0.059,0.007,0.0175,795.124,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-15",4,3.01,140.84,,0,0.001,95.857,0.059,0.016,0.038,1612.783,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-16",3,2.08,95,,0,0.001,64.682,0.059,0.009,0.0177,1088.003,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-17",1,0.58,19.14,,0,0.001,14.558,0.059,0.007,0.054,244.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-20",3,1.51,56.02,,0,0.001,39.617,0.0597,0.009,0.0277,665.917,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-21",3,2.33,105.15,,0,0.001,71.28,0.059,0.012,0.0223,1199.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-22",3,1.85,80.97,,0,0.001,55.655,0.0593,0.015,0.0297,936.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-24",4,3.35,156.01,,0.001,0.001,105.03,0.059,0.014,0.0178,1766.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-25",3,2.6,117.68,,0,0.001,80.404,0.059,0.01,0.0147,1352.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-29",4,3.33,155.15,,0.001,0.001,104.387,0.0593,0.01,0.0133,1756.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-11-30",5,4.39,209,,0.001,0.001,139.576,0.059,0.013,0.0124,2350.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-01",8,6.91,334.12,,0.001,0.001,221.886,0.0593,0.022,0.013,3732.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-02",5,4.33,209.85,,0.001,0.001,140.377,0.0592,0.013,0.0126,2360.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-03",9,6.8,284.29,,0.001,0.001,192.655,0.0594,0.022,0.0177,3240.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-04",10,8.91,453.97,,0.002,0.001,297.607,0.059,0.03,0.0159,5007.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-06",5,4.1,193.43,,0.001,0.001,129.613,0.0592,0.014,0.0146,2180.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-07",5,4.56,220.68,,0.001,0.001,147.416,0.0594,0.015,0.012,2479.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-08",6,4.63,210.54,,0.001,0.001,141.717,0.0592,0.013,0.0118,2384.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-09",7,5.78,265.38,,0.001,0.001,177.954,0.0593,0.017,0.0126,2994.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-10",9,8.39,410.12,,0.001,0.001,272.698,0.0591,0.026,0.0116,4587.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-11",10,8.88,460.7,,0.002,0.001,301.914,0.0591,0.029,0.0126,5078.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-12",8,7.33,397.72,,0.001,0.001,257.095,0.059,0.021,0.0098,4327.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-13",7,5.55,279.99,,0.001,0.001,186.926,0.059,0.019,0.0146,3145.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-14",9,7.88,374.2,,0.001,0.001,248.706,0.059,0.02,0.0129,4186.045,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-15",10,8.63,423.64,,0.001,0.001,279.864,0.0591,0.029,0.018,4710.698,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-16",11,8.69,431.39,,0.001,0.001,283.986,0.0591,0.026,0.0188,4780.624,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-18",6,5.51,251.44,,0.001,0.001,172.17,0.0592,0.016,0.0123,2895.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-19",4,0.88,0,,0,0.0008,4.35,0.0598,0.001,0.035,73.047,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-22",3,0.65,0.18,,0,0.001,2.859,0.0597,0.004,0.1523,47.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-23",2,1.33,55.12,,0,0.001,38.318,0.0595,0.01,0.024,644.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-25",2,1.25,51.71,,0,0.001,35.756,0.059,0.008,0.0265,602.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-27",5,4.31,204.29,,0.001,0.001,136.033,0.059,0.012,0.0122,2288.187,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-28",3,2.01,94.17,,0,0.001,63.564,0.0593,0.008,0.0127,1069.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Midway Peaking",56639,"2",,"2020-12-31",2,1.33,55.12,,0,0.001,38.271,0.059,0.005,0.013,643.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-02",3,2.03,148.21,,0,0.001,81.302,0.059,0.01,0.0247,1368.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-09",6,4.53,454.57,,0.001,0.001,234.816,0.0592,0.023,0.0252,3952.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-10",3,2.78,255.1,,0.001,0.001,134.43,0.059,0.019,0.0177,2261.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-13",6,5.27,533.22,,0.001,0.001,274.971,0.059,0.025,0.0132,4626.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-14",3,1.78,162.76,,0,0.001,85.195,0.059,0.014,0.0197,1433.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-15",10,8.57,850.08,,0.002,0.001,440.713,0.059,0.042,0.0137,7417.973,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-16",8,6.83,641.59,,0.002,0.001,335.585,0.059,0.037,0.0131,5648.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-17",8,7.09,662.7,,0.002,0.001,347.625,0.059,0.038,0.0135,5851.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-18",5,4.52,399.76,,0.001,0.001,211.61,0.059,0.021,0.014,3560.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-19",7,6.28,615.04,,0.002,0.001,319.2,0.059,0.031,0.0117,5372.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-20",9,7.53,747.98,,0.002,0.001,387.275,0.059,0.035,0.0126,6517.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-23",8,7.1,648.28,,0.002,0.001,345.34,0.059,0.033,0.013,5810.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-25",7,6.8,696.9,,0.002,0.001,363.3,0.059,0.029,0.0101,6111.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-27",2,1.55,136.36,,0,0.001,72.323,0.059,0.014,0.0205,1216.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-28",3,2.28,210.53,,0.001,0.001,110.609,0.059,0.013,0.016,1861.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-29",10,8.83,886.06,,0.002,0.001,458.948,0.059,0.044,0.0123,7720.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-30",8,7.02,663.71,,0.002,0.001,346.363,0.059,0.032,0.0126,5829.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-01",11,9.06,842.08,,0.002,0.001,442.612,0.059,0.039,0.0122,7449.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-03",6,4.55,431.68,,0.001,0.001,226.277,0.059,0.033,0.0182,3807.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-04",9,7.3,718.19,,0.002,0.001,372.516,0.059,0.037,0.0166,6268.921,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-07",2,1,77.8,,0,0.001,42.12,0.059,0.006,0.018,709.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-08",6,5.3,515.38,,0.001,0.001,268.912,0.059,0.018,0.0092,4524.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-11",10,8.33,802.12,,0.002,0.001,418.866,0.059,0.039,0.0151,7049.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-12",7,6.05,605.69,,0.002,0.001,314.515,0.059,0.026,0.0113,5292.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-13",9,7.81,758.11,,0.002,0.001,394.925,0.059,0.039,0.0128,6646.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-14",8,7.03,676.93,,0.002,0.001,352.861,0.059,0.034,0.0136,5937.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-16",6,5.27,465.14,,0.001,0.001,247.123,0.059,0.021,0.0123,4160.323,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-17",3,1.78,153.91,,0,0.001,81.888,0.059,0.012,0.0177,1378.393,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-18",7,5.35,512.13,,0.001,0.001,266.816,0.059,0.028,0.0174,4489.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-19",9,7.39,715.02,,0.002,0.001,372.89,0.059,0.036,0.0153,6273.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-20",6,4.97,449.45,,0.001,0.001,238.014,0.059,0.019,0.0162,4005.122,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-21",9,8.15,800.87,,0.002,0.001,416.328,0.059,0.039,0.0114,7005.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-24",9,7.8,745.44,,0.002,0.001,391.049,0.059,0.039,0.0131,6577.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-25",5,4.27,413.75,,0.001,0.001,217.373,0.059,0.02,0.0132,3658.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-26",11,9,877.5,,0.002,0.001,460.912,0.059,0.047,0.0165,7756.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-27",8,6.6,606,,0.002,0.001,319.57,0.059,0.029,0.0146,5379.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-01",7,6.3,624.28,,0.002,0.001,321.733,0.059,0.029,0.0126,5416.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-02",10,9.08,843.91,,0.002,0.001,439.982,0.0591,0.04,0.0126,7400.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-03",10,8.58,844.24,,0.002,0.001,436.092,0.059,0.041,0.0121,7338.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-04",6,5.52,542.74,,0.001,0.001,281.238,0.059,0.023,0.012,4732.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-05",7,6.08,587.92,,0.002,0.001,305.539,0.059,0.032,0.0147,5140.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-06",9,6.85,615.43,,0.002,0.001,330.145,0.059,0.029,0.0212,5554.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-07",2,1.25,99.9,,0,0.001,54.83,0.059,0.01,0.0215,922.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-08",5,4.09,404.2,,0.001,0.001,214.426,0.059,0.021,0.013,3608.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-09",10,8.02,794.32,,0.002,0.001,421.647,0.059,0.037,0.0143,7097.157,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-10",10,8.87,890.79,,0.002,0.001,470.901,0.059,0.041,0.0122,7924.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-11",10,8.83,867.87,,0.002,0.001,461.171,0.059,0.04,0.0122,7761.247,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-20",1,0.27,0,,0,0.001,2.079,0.06,0.002,0.133,34.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-04-30",9,8.07,845.49,,0.002,0.001,440.191,0.059,0.029,0.0126,7405.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-01",3,2.17,217.06,,0.001,0.001,112.403,0.059,0.007,0.0073,1892.343,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-04",4,3.57,343.85,,0.001,0.001,180.499,0.059,0.018,0.0145,3037.191,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-06",4,3.28,295.47,,0.001,0.001,158.062,0.059,0.016,0.0145,2658.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-07",3,2.3,210.42,,0.001,0.001,112.579,0.059,0.013,0.016,1894.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-08",4,3.6,344.38,,0.001,0.001,183.083,0.059,0.019,0.0125,3081.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-11",4,3.52,342.52,,0.001,0.001,181.048,0.059,0.018,0.0145,3046.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-12",5,3.88,361.14,,0.001,0.001,192.878,0.059,0.018,0.0288,3243.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-13",5,3.75,364.65,,0.001,0.001,191.935,0.059,0.016,0.0162,3229.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-14",4,3.27,290.17,,0.001,0.001,154.746,0.059,0.016,0.0145,2603.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-15",5,3.79,344.58,,0.001,0.001,184.444,0.059,0.016,0.0154,3102.769,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-16",7,6.05,582.03,,0.002,0.001,308.356,0.059,0.024,0.0113,5187.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-26",6,4.78,370.81,,0.001,0.001,205.82,0.059,0.016,0.024,3463.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-27",5,4.03,385.31,,0.001,0.001,204.015,0.059,0.017,0.0144,3433.851,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-28",4,2.28,184.31,,0.001,0.001,101.301,0.0593,0.01,0.034,1704.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-29",2,1.28,82.48,,0,0.001,47.356,0.059,0.007,0.027,797.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-05-31",3,1.55,117.84,,0,0.001,65.792,0.059,0.009,0.0203,1107.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-01",8,7.25,672.77,,0.002,0.001,359.543,0.059,0.027,0.0103,6052.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-02",4,3.3,308.2,,0.001,0.001,164.206,0.059,0.016,0.0133,2762.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-03",15,12.39,1092.49,,0.003,0.001,590.68,0.059,0.051,0.0169,9937.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-04",7,5.26,471.29,,0.001,0.001,252.13,0.059,0.019,0.0223,4243.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-08",5,4.28,421.89,,0.001,0.001,221.169,0.059,0.02,0.0128,3721.566,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-09",8,7.3,727.23,,0.002,0.001,381.865,0.059,0.029,0.0103,6427.549,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-10",9,8.58,867.37,,0.002,0.001,455.443,0.059,0.035,0.0096,7662.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-11",8,6.03,555.96,,0.001,0.001,296.645,0.0591,0.027,0.0123,4989.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-12",5,3.78,319.56,,0.001,0.001,173.237,0.059,0.016,0.0132,2915.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-13",3,2.53,235.92,,0.001,0.001,125.033,0.059,0.018,0.0167,2104.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-14",5,4.28,415.96,,0.001,0.001,219.008,0.059,0.022,0.0124,3686.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-15",3,2.03,184.57,,0,0.001,98.308,0.059,0.015,0.016,1654.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-16",8,5.31,479.01,,0.001,0.001,255.812,0.059,0.024,0.0249,4304.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-17",4,3.07,294.95,,0.001,0.001,156.094,0.059,0.013,0.031,2625.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-18",4,3.23,311.65,,0.001,0.001,164.632,0.059,0.015,0.013,2769.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-19",5,4.05,393.69,,0.001,0.001,207.661,0.059,0.018,0.0118,3494.619,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-20",5,4.3,420.72,,0.001,0.001,222.758,0.059,0.021,0.0116,3748.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-21",5,4.05,392.69,,0.001,0.001,209.15,0.059,0.018,0.0118,3518.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-22",6,5.3,517.4,,0.001,0.001,274.584,0.059,0.021,0.0128,4620.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-23",8,7.53,744.91,,0.002,0.001,393.667,0.059,0.029,0.01,6623.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-24",11,10,1000,,0.003,0.001,525.9,0.059,0.036,0.0089,8848.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-25",4,3.03,289.35,,0.001,0.001,153.048,0.0593,0.015,0.0345,2573.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-26",8,7.05,679.39,,0.002,0.001,360.3,0.059,0.027,0.0101,6065.711,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-27",10,9.78,973.66,,0.003,0.001,513.526,0.059,0.039,0.0094,8642.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-28",4,3.28,309.7,,0.001,0.001,163.356,0.059,0.016,0.0135,2750.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-29",5,4.02,380.38,,0.001,0.001,200.606,0.059,0.017,0.012,3377.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-06-30",6,5.05,487.96,,0.001,0.001,257.328,0.059,0.021,0.0112,4329.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-01",6,5.07,495.12,,0.001,0.001,260.322,0.059,0.021,0.0112,4382.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-02",5,3.8,369.14,,0.001,0.001,194.216,0.059,0.017,0.0148,3268.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-03",8,6.75,679.4,,0.002,0.001,356.56,0.059,0.027,0.0103,5998.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-04",6,5.02,504.84,,0.001,0.001,266.124,0.059,0.022,0.011,4477.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-05",7,6.02,606.94,,0.002,0.001,318.458,0.059,0.024,0.0126,5359.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-06",2,1.32,109.08,,0,0.001,59.094,0.059,0.011,0.018,994.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-07",3,2.32,213.26,,0.001,0.001,113.675,0.059,0.013,0.0153,1912.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-08",4,3.28,316.15,,0.001,0.001,167.255,0.059,0.015,0.0128,2814.229,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-09",6,5.28,520.36,,0.001,0.001,274.536,0.059,0.02,0.013,4620.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-10",5,4.53,441.06,,0.001,0.001,233.284,0.059,0.022,0.0118,3926.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-11",10,9.28,888.59,,0.002,0.001,469.642,0.059,0.035,0.0099,7900.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-12",9,8.28,771.11,,0.002,0.001,410.957,0.059,0.031,0.0102,6915.159,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-14",2,1.53,134.68,,0,0.001,72.584,0.059,0.013,0.019,1221.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-17",3,2.54,233.8,,0.001,0.001,125.054,0.059,0.014,0.016,2104.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-18",7,6.55,636.71,,0.002,0.001,336.99,0.059,0.029,0.0109,5670.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-21",6,5.05,478.14,,0.001,0.001,254.756,0.059,0.024,0.0112,4286.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-22",5,4.28,416.16,,0.001,0.001,220.048,0.059,0.021,0.0118,3703.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-23",2,1.28,105.44,,0,0.001,57.256,0.059,0.012,0.019,963.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-24",6,5.53,536.57,,0.001,0.001,285.424,0.059,0.025,0.011,4801.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-25",6,5.28,519.9,,0.001,0.001,274.39,0.059,0.022,0.0112,4618.189,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-26",10,9.03,902.55,,0.002,0.001,475.02,0.059,0.034,0.0096,7992.542,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-27",8,7.53,738.04,,0.002,0.001,389.303,0.059,0.032,0.0103,6552.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-28",5,4.3,414.86,,0.001,0.001,219.706,0.059,0.019,0.0122,3697.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-29",6,5.3,524.45,,0.001,0.001,276.085,0.059,0.023,0.0115,4645.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-30",9,8.3,790.42,,0.002,0.001,420.422,0.059,0.034,0.0099,7074.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-03",7,5.28,447.42,,0.001,0.001,244.088,0.0591,0.019,0.0224,4107.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-05",2,1.53,128.88,,0,0.001,70.299,0.059,0.01,0.0205,1181.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-06",3,2.25,182.9,,0.001,0.001,100.585,0.059,0.015,0.016,1691.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-07",4,3.28,314.52,,0.001,0.001,166.084,0.059,0.017,0.0143,2794.743,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-08",3,2.28,210.87,,0.001,0.001,111.987,0.059,0.014,0.0167,1885.065,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-09",5,4.58,438.35,,0.001,0.001,230.698,0.059,0.021,0.0114,3882.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-10",7,6.25,594.3,,0.002,0.001,313.205,0.059,0.024,0.0106,5271.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-11",3,2.28,210.5,,0.001,0.001,111.88,0.059,0.013,0.0157,1881.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-12",10,9,878.9,,0.002,0.001,463.735,0.059,0.036,0.0097,7802.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-13",15,14.35,1456.85,,0.004,0.001,764.57,0.059,0.05,0.0097,12865.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-14",15,13.71,1350.92,,0.004,0.001,712.381,0.059,0.048,0.0089,11986.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-15",19,18.28,1795.24,,0.005,0.001,944.47,0.059,0.06,0.0081,15890.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-16",19,17.97,1757.81,,0.005,0.001,923.269,0.0591,0.058,0.0081,15532.999,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-17",24,23.13,2036.12,,0.006,0.001,1104.918,0.059,0.069,0.0114,18595.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-18",23,22.15,2013,,0.005,0.001,1079.315,0.059,0.068,0.0087,18161.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-19",12,10.52,947.77,,0.003,0.001,507.431,0.059,0.037,0.0123,8539.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-20",9,6.46,358.8,,0.001,0.001,217.029,0.059,0.023,0.0236,3652.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-21",8,5.8,465.5,,0.001,0.001,255.091,0.0591,0.024,0.0158,4291.793,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-22",11,8.56,814.46,,0.002,0.001,432.004,0.0592,0.035,0.0188,7268.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-23",6,3.11,265.75,,0.001,0.001,142.616,0.0592,0.017,0.0282,2400.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-24",11,9.78,895.57,,0.002,0.001,476.063,0.059,0.034,0.0095,8008.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-25",2,1.27,103.49,,0,0.001,56.249,0.059,0.016,0.0335,946.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-26",7,4.54,397.18,,0.001,0.001,213.797,0.059,0.023,0.0383,3598.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-27",6,3.54,189.15,,0.001,0.001,115.002,0.0593,0.013,0.0352,1935.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-28",6,4.53,305.29,,0.001,0.001,173.245,0.0592,0.019,0.0152,2914.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-29",3,2.35,204.24,,0.001,0.001,108.904,0.059,0.014,0.0143,1833.379,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-30",2,1.3,99.9,,0,0.001,54.74,0.059,0.008,0.024,921.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-01",2,1.3,111.8,,0,0.001,60.052,0.059,0.011,0.022,1010.831,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-03",4,2.55,231.2,,0.001,0.001,123.315,0.0593,0.012,0.032,2075.485,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-04",7,5.88,532.61,,0.001,0.001,284.883,0.059,0.028,0.0179,4793.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-05",9,8.13,733.64,,0.002,0.001,391.965,0.0591,0.027,0.0189,6596.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-06",11,10.85,1002.43,,0.003,0.001,534.764,0.059,0.039,0.0091,8999.423,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-07",8,7.17,659.02,,0.002,0.001,352.774,0.059,0.025,0.012,5935.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-08",4,3.03,288.48,,0.001,0.001,152.688,0.059,0.014,0.0345,2569.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-09",2,1.23,86.16,,0,0.001,48.633,0.059,0.007,0.029,817.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-11",5,3.93,321.76,,0.001,0.001,174.816,0.059,0.024,0.0152,2942.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-12",3,2.57,238.18,,0.001,0.001,126.176,0.059,0.014,0.0167,2123.297,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-13",5,4.78,454.74,,0.001,0.001,241.046,0.059,0.023,0.012,4056.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-14",5,4.57,443.04,,0.001,0.001,235.183,0.059,0.022,0.0116,3958.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-15",5,3.81,335.96,,0.001,0.001,180.679,0.059,0.024,0.0162,3040.299,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-16",5,4.27,408.54,,0.001,0.001,217.89,0.059,0.02,0.0128,3666.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-17",9,7.86,767.14,,0.002,0.001,407.51,0.059,0.037,0.0144,6857.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-18",4,2.97,245.31,,0.001,0.001,132.783,0.059,0.014,0.0135,2234.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-19",5,4.28,414.02,,0.001,0.001,217.723,0.059,0.019,0.0128,3663.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-20",6,5.55,537.51,,0.001,0.001,282.707,0.059,0.023,0.0115,4759.494,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-21",4,3.28,274.91,,0.001,0.001,148.925,0.059,0.015,0.0143,2505.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-22",4,3.28,266.18,,0.001,0.001,146.194,0.059,0.015,0.0145,2459.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-23",4,3.03,241.38,,0.001,0.001,133.477,0.059,0.014,0.0143,2246.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-24",2,1.28,87.59,,0,0.001,49.691,0.059,0.009,0.0215,836.297,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-27",3,2,173.15,,0,0.001,94.22,0.059,0.011,0.0223,1586.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-28",6,4.85,404.73,,0.001,0.001,220.198,0.059,0.024,0.0132,3706.171,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-29",8,6.78,649.15,,0.002,0.001,343.661,0.059,0.025,0.0204,5783.411,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-09-30",9,8.02,777.87,,0.002,0.001,412.199,0.059,0.029,0.0109,6937.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-01",8,7.05,670.32,,0.002,0.001,361.222,0.059,0.028,0.0104,6076.642,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-02",5,4.53,431.27,,0.001,0.001,232.514,0.059,0.022,0.0118,3912.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-03",4,3.27,315.3,,0.001,0.001,168.66,0.059,0.016,0.0138,2839.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-04",6,5.05,499.15,,0.001,0.001,268.385,0.059,0.021,0.013,4516.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-05",9,6.74,664.5,,0.002,0.001,354.203,0.059,0.031,0.0281,5958.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-07",9,7.34,691,,0.002,0.001,366.026,0.059,0.037,0.0168,6158.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-08",2,1.58,109.02,,0,0.001,60.402,0.059,0.01,0.0225,1015.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-10",2,1.28,91.64,,0,0.001,50.39,0.0595,0.008,0.028,847.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-11",1,0.22,0,,0,0.001,1.716,0.059,0.002,0.112,28.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-24",3,1.36,35.7,,0,0.001,26.47,0.0593,0.01,0.0657,445.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-25",6,5.18,440.73,,0.001,0.001,237.382,0.059,0.021,0.0118,3994.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-26",7,4.58,401.28,,0.001,0.001,216.005,0.0591,0.025,0.0281,3634.429,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-27",11,9.76,972.91,,0.003,0.001,509.228,0.059,0.045,0.0118,8571.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-28",7,5.83,554.33,,0.001,0.001,292.321,0.059,0.033,0.0143,4920.183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-29",4,3.3,321.85,,0.001,0.001,171,0.059,0.017,0.0143,2877.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-30",8,5.86,494.35,,0.001,0.001,269.301,0.059,0.025,0.0224,4532.359,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-10-31",4,3.01,251.66,,0.001,0.001,137.603,0.059,0.015,0.0145,2315.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-01",5,4.26,422.99,,0.001,0.001,224.031,0.059,0.02,0.0124,3767.847,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-02",12,10.31,1025.61,,0.003,0.001,539.703,0.0591,0.047,0.0111,9081.941,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-03",9,8.06,796.27,,0.002,0.001,418.909,0.059,0.04,0.0123,7048.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-04",14,12.78,1272.3,,0.003,0.001,670.314,0.059,0.054,0.0106,11279.323,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-05",12,10.81,1057.17,,0.003,0.001,554.558,0.059,0.047,0.0108,9333.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-06",8,6.3,565.43,,0.002,0.001,300.194,0.0591,0.022,0.0204,5050.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-07",3,1.28,67.58,,0,0.001,40.896,0.059,0.007,0.0423,688.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-08",9,8.15,741.65,,0.002,0.001,391.76,0.0591,0.03,0.0191,6591.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-09",14,12.68,1194.52,,0.003,0.001,630.718,0.059,0.042,0.0086,10611.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-10",11,9.38,934.3,,0.002,0.001,484.298,0.059,0.042,0.0133,8147.963,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-11",11,9.54,918.03,,0.002,0.001,481.395,0.059,0.041,0.0122,8099.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-12",8,7.33,710.65,,0.002,0.001,372.754,0.059,0.039,0.0135,6271.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-13",10,7.56,588.54,,0.002,0.001,322.461,0.0591,0.029,0.0202,5425.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-14",6,3.94,273.52,,0.001,0.001,154.108,0.059,0.018,0.0165,2592.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-15",6,5.51,491.95,,0.001,0.001,261.868,0.059,0.022,0.0127,4407.627,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-16",11,7.56,655.66,,0.002,0.001,350.362,0.059,0.029,0.0269,5895.789,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-17",9,7.06,671.71,,0.002,0.001,353.037,0.0591,0.035,0.0128,5938.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-18",12,7.79,552,,0.002,0.001,308.914,0.0591,0.035,0.0279,5198.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-19",5,4.03,377.23,,0.001,0.001,197.989,0.059,0.021,0.0144,3331.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-20",7,5.99,564.15,,0.001,0.001,296.528,0.059,0.034,0.015,4991.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-21",7,6,559.54,,0.001,0.001,296.374,0.059,0.025,0.0117,4988.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-22",6,5.09,420.23,,0.001,0.001,228.49,0.059,0.021,0.0127,3844.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-23",8,6.08,476.39,,0.001,0.001,261.418,0.059,0.028,0.0159,4397.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-24",12,10.81,1046.79,,0.003,0.001,555.582,0.059,0.045,0.0116,9350.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-25",10,7.6,685.6,,0.002,0.001,368.035,0.059,0.034,0.0145,6191.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-26",5,3.09,249.38,,0.001,0.001,136.017,0.059,0.019,0.0208,2288.419,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-27",4,3.28,266.44,,0.001,0.001,145.863,0.059,0.016,0.0155,2454.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-28",6,5.05,488.52,,0.001,0.001,257.803,0.059,0.022,0.014,4336.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-29",7,6.28,616.92,,0.002,0.001,325.111,0.059,0.028,0.012,5467.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-11-30",8,7.01,680.37,,0.002,0.001,359.08,0.059,0.039,0.013,6042.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-01",13,11.99,1185.54,,0.003,0.001,622.567,0.059,0.053,0.0114,10475.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-02",12,10.85,1079.11,,0.003,0.001,565.638,0.059,0.046,0.0114,9516.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-03",12,11.18,1112.22,,0.003,0.001,582.138,0.059,0.049,0.011,9795.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-04",16,14.33,1444.84,,0.004,0.001,754.199,0.059,0.058,0.0104,12689.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-05",12,9.46,913.07,,0.002,0.001,481.095,0.059,0.041,0.0183,8094.303,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-06",8,7.28,717.71,,0.002,0.001,376.958,0.059,0.03,0.0111,6343.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-07",13,11.56,1136.3,,0.003,0.001,597.594,0.059,0.049,0.0112,10054.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-08",11,10.2,989.4,,0.003,0.001,522.742,0.059,0.045,0.0117,8796.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-09",16,13.57,1311.22,,0.003,0.001,690.884,0.059,0.05,0.0163,11627.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-10",13,11.35,1100.51,,0.003,0.001,579.836,0.059,0.048,0.0125,9757.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-11",19,17.33,1696.07,,0.005,0.001,891.822,0.0591,0.068,0.0095,15007.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-13",24,23.13,2246.81,,0.006,0.001,1189.211,0.059,0.077,0.0119,20011.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-14",18,16.93,1598.8,,0.004,0.001,847.597,0.059,0.055,0.0083,14261.071,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-15",15,13.73,1331.84,,0.004,0.001,702.604,0.059,0.052,0.0109,11821.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-16",19,18.28,1872.13,,0.005,0.001,975.561,0.059,0.062,0.0082,16415.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-17",5,3.43,306.13,,0.001,0.001,163.712,0.0592,0.018,0.014,2753.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-18",10,9.3,901,,0.002,0.001,474.892,0.059,0.044,0.0124,7991.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-19",4,2.44,193.64,,0.001,0.001,105.904,0.0593,0.023,0.0215,1782.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-20",8,5.81,552.82,,0.001,0.001,292.432,0.0591,0.032,0.0244,4919.999,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-21",9,7.55,734.02,,0.002,0.001,388.503,0.059,0.04,0.0142,6538.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-22",8,6.08,586.68,,0.002,0.001,310.185,0.059,0.032,0.0139,5220.607,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-23",9,6.18,577.93,,0.002,0.001,307.721,0.059,0.04,0.0159,5175.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-24",4,3.3,320.87,,0.001,0.001,168.454,0.059,0.019,0.0155,2834.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-25",4,3.3,308.26,,0.001,0.001,162.851,0.059,0.018,0.0153,2740.799,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-26",2,1.34,85.57,,0,0.001,49.67,0.0595,0.011,0.02,836.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-27",11,9.56,934.64,,0.002,0.001,491.508,0.059,0.044,0.0117,8269.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-28",17,15.85,1556.15,,0.004,0.001,817.211,0.059,0.06,0.0096,13751.927,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-29",6,4.35,403.32,,0.001,0.001,213.227,0.0592,0.028,0.017,3586.817,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"1",,"2020-12-31",7,6.1,573.26,,0.002,0.001,302.762,0.059,0.033,0.0149,5096.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-02",3,2.03,143.15,,0,0.001,80.287,0.0593,0.01,0.0243,1350.469,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-09",6,4.53,457.44,,0.001,0.001,237.831,0.059,0.023,0.0253,4003.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-10",3,2.78,261.76,,0.001,0.001,139.114,0.059,0.021,0.019,2340.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-13",8,6.55,645.76,,0.002,0.001,338.717,0.059,0.034,0.0175,5701.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-14",8,7.03,625.19,,0.002,0.001,333.14,0.0591,0.03,0.0113,5603.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-15",12,11.1,998.93,,0.003,0.001,534.833,0.059,0.05,0.0126,9003.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-16",5,4.3,402.44,,0.001,0.001,212.81,0.059,0.025,0.0142,3580.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-17",5,4.56,419.96,,0.001,0.001,222.516,0.059,0.024,0.014,3743.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-18",4,3.52,313.56,,0.001,0.001,167.32,0.059,0.019,0.0163,2815.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-20",3,1.7,140.9,,0,0.001,75.965,0.059,0.013,0.0243,1277.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-21",3,1.27,83.23,,0,0.001,47.452,0.0593,0.009,0.0427,798.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-23",8,7.12,649.94,,0.002,0.001,349.507,0.059,0.035,0.0134,5883.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-25",7,6.78,690.98,,0.002,0.001,363.404,0.059,0.033,0.0114,6114.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-27",2,1.55,134.81,,0,0.001,72.323,0.059,0.015,0.0225,1217.489,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-28",3,2.28,209.9,,0.001,0.001,111.395,0.059,0.014,0.017,1874.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-29",10,8.83,885.41,,0.002,0.001,462.88,0.059,0.046,0.0129,7790.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-30",8,7.02,658.69,,0.002,0.001,348.682,0.059,0.034,0.0136,5866.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-01",11,9.06,827.82,,0.002,0.001,440.709,0.059,0.041,0.0126,7417.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-02",3,2.05,178.7,,0,0.001,96.176,0.059,0.014,0.0187,1618.837,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-03",5,4.05,367.9,,0.001,0.001,195.607,0.059,0.033,0.0214,3291.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-04",11,9.03,855.76,,0.002,0.001,451.413,0.059,0.042,0.0155,7597.659,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-05",6,4.31,395.46,,0.001,0.001,209.526,0.059,0.03,0.0173,3526.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-07",3,2.25,208.8,,0.001,0.001,110.79,0.059,0.014,0.0183,1863.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-08",9,7.39,687.3,,0.002,0.001,364.838,0.059,0.038,0.0158,6138.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-09",7,5.78,552.12,,0.001,0.001,291.684,0.059,0.024,0.0146,4908.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-10",7,6.3,578.44,,0.002,0.001,307.766,0.059,0.026,0.0146,5176.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-11",10,8.33,797.07,,0.002,0.001,419.684,0.059,0.04,0.0157,7062.441,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-12",9,7.58,726.63,,0.002,0.001,383.339,0.059,0.041,0.0138,6449.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-13",10,8.81,862.92,,0.002,0.001,453.941,0.059,0.046,0.0132,7635.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-14",9,8.28,805.96,,0.002,0.001,423.148,0.059,0.043,0.0136,7119.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-15",3,2.05,191.1,,0.001,0.001,101.16,0.059,0.012,0.0223,1701.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-16",6,5.27,468.38,,0.001,0.001,250.549,0.059,0.022,0.0127,4214.652,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-17",3,1.77,153.95,,0,0.001,82.746,0.059,0.013,0.0183,1392.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-18",7,5.35,510.43,,0.001,0.001,268.407,0.059,0.031,0.0193,4518.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-19",9,7.39,699.4,,0.002,0.001,369.057,0.059,0.037,0.0158,6211.659,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-20",6,5,448.55,,0.001,0.001,240.375,0.059,0.021,0.0162,4043.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-21",9,8.15,798.94,,0.002,0.001,419.358,0.059,0.043,0.0126,7056.854,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-24",9,7.8,737.99,,0.002,0.001,390.859,0.059,0.041,0.0136,6576.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-25",8,6.6,603.2,,0.002,0.001,322.673,0.059,0.036,0.0145,5429.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-26",12,8.4,789.81,,0.002,0.001,421.486,0.0591,0.053,0.0239,7090.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-27",5,4.55,414.8,,0.001,0.001,221.165,0.059,0.021,0.0136,3720.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-01",7,6.3,622.65,,0.002,0.001,323.208,0.059,0.029,0.0124,5439.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-02",10,9.08,842.48,,0.002,0.001,443.669,0.059,0.042,0.013,7465.069,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-03",9,7.33,708.61,,0.002,0.001,371.048,0.059,0.038,0.0129,6242.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-04",6,5.52,545.02,,0.001,0.001,285.348,0.059,0.025,0.0125,4803.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-05",8,7.11,682.56,,0.002,0.001,358.696,0.059,0.035,0.0141,6034.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-06",10,7.85,714.15,,0.002,0.001,385.979,0.059,0.037,0.0207,6495.734,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-07",8,7.03,680.25,,0.002,0.001,365.52,0.059,0.038,0.0129,6150.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-08",9,7.35,704.32,,0.002,0.001,378.982,0.059,0.039,0.0142,6380.099,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-12",2,0.41,12.21,,0,0.001,8.866,0.059,0.005,0.038,149.166,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-19",4,3.31,322.28,,0.001,0.001,165.523,0.059,0.013,0.009,2786.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-23",2,1.53,128.6,,0,0.001,67.945,0.059,0.016,0.0245,1143.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-25",3,2.03,161.17,,0,0.001,85.54,0.059,0.013,0.019,1438.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-27",7,5.31,482.64,,0.001,0.001,251.357,0.0591,0.031,0.0173,4230.439,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-30",4,3.27,283.95,,0.001,0.001,148.909,0.059,0.019,0.0173,2505.377,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-01",3,2.53,238.31,,0.001,0.001,124.134,0.059,0.015,0.018,2088.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-07",4,3.22,294.17,,0.001,0.001,152.957,0.059,0.017,0.0173,2574.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-09",9,6.82,675.01,,0.002,0.001,349.397,0.0591,0.038,0.022,5880.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-14",1,0.62,21.08,,0,0.001,14.384,0.06,0.008,0.066,241.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-16",3,2.9,282.78,,0.001,0.001,146.762,0.059,0.012,0.01,2468.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-20",3,1.98,183.12,,0,0.001,96.032,0.059,0.018,0.019,1616.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-21",2,1.12,111.32,,0,0.001,57.456,0.059,0.011,0.06,967.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-22",2,1.15,69.05,,0,0.001,40.165,0.059,0.003,0.008,675.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-29",9,8.07,838.21,,0.002,0.001,431.209,0.0591,0.032,0.0188,7255.927,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-04-30",3,2.17,215.06,,0.001,0.001,110.686,0.059,0.007,0.0077,1861.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-02",5,4.04,377.08,,0.001,0.001,195.83,0.059,0.019,0.0138,3296.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-04",5,4.54,423.38,,0.001,0.001,220.43,0.059,0.02,0.0136,3708.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-05",2,1.53,97.65,,0,0.001,56.142,0.059,0.011,0.023,943.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-06",4,3.27,295.3,,0.001,0.001,155.487,0.059,0.017,0.0155,2616.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-07",3,2.3,211.68,,0.001,0.001,111.332,0.059,0.015,0.0187,1873.483,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-08",6,5.13,469.77,,0.001,0.001,247.453,0.059,0.031,0.0145,4164.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-09",7,6.51,637.38,,0.002,0.001,331.891,0.059,0.028,0.0119,5586.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-10",3,1.8,143.8,,0,0.001,76.92,0.059,0.01,0.0213,1295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-11",5,4.52,442.92,,0.001,0.001,230,0.059,0.021,0.0136,3870.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-12",5,4.23,414.48,,0.001,0.001,214.416,0.059,0.022,0.0142,3608.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-13",5,3.5,336.1,,0.001,0.001,174.81,0.0592,0.018,0.0296,2942.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-14",6,4.57,394.38,,0.001,0.001,208.746,0.059,0.024,0.0192,3513.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-15",5,3.8,321.1,,0.001,0.001,176.528,0.059,0.017,0.0166,2972.574,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-16",7,6.04,485.78,,0.001,0.001,269.516,0.059,0.026,0.013,4535.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-17",4,3.28,320.26,,0.001,0.001,172.382,0.059,0.017,0.0188,2900.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-20",3,2.81,160.59,,0.001,0.001,99.773,0.0593,0.015,0.017,1677.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-26",6,4.78,378.15,,0.001,0.001,214.327,0.059,0.018,0.0238,3606.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-27",6,5.03,458.97,,0.001,0.001,251.466,0.059,0.019,0.014,4232.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-28",4,2.28,184.18,,0.001,0.001,103.619,0.0593,0.011,0.0328,1744.353,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-29",2,1.28,82.1,,0,0.001,48.688,0.0595,0.008,0.028,818.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-30",3,1.3,60.39,,0,0.001,40.809,0.0593,0.007,0.039,686.473,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-05-31",4,2.53,196.17,,0.001,0.001,110.71,0.059,0.015,0.0205,1862.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-01",4,3.06,233.15,,0.001,0.001,130.432,0.059,0.025,0.023,2196.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-03",3,1.78,144.72,,0,0.001,79.982,0.059,0.011,0.0423,1346.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-04",9,6.82,619.78,,0.002,0.001,326.339,0.059,0.029,0.0168,5490.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-07",3,1.58,143.8,,0,0.001,75.12,0.0593,0.011,0.0397,1264.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-08",7,6.13,585.89,,0.002,0.001,303.974,0.059,0.034,0.0141,5114.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-09",8,7.3,730.23,,0.002,0.001,377.184,0.059,0.032,0.0115,6347.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-10",10,9.6,984.98,,0.003,0.001,509.505,0.059,0.04,0.0096,8571.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-11",8,7.12,689.5,,0.002,0.001,359.333,0.059,0.028,0.0114,6047.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-12",5,3.77,324.04,,0.001,0.001,171.648,0.059,0.016,0.013,2888.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-13",3,2.53,235.92,,0.001,0.001,123.239,0.059,0.018,0.017,2074.197,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-14",5,4.28,414.08,,0.001,0.001,216.204,0.059,0.023,0.013,3638.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-15",3,2.03,184.57,,0,0.001,97.18,0.0593,0.016,0.0167,1634.161,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-16",8,5.33,476.19,,0.001,0.001,250.967,0.059,0.027,0.0256,4225.067,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-17",4,3.07,294.61,,0.001,0.001,153.519,0.059,0.014,0.0315,2583.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-18",6,5.23,526.88,,0.001,0.001,272.665,0.059,0.023,0.0118,4587.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-19",5,4.05,388.69,,0.001,0.001,202.321,0.059,0.02,0.013,3407.001,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-20",5,4.3,417.84,,0.001,0.001,218.41,0.059,0.023,0.0126,3676.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-21",5,4.05,394.11,,0.001,0.001,207.277,0.059,0.019,0.0126,3487.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-22",6,5.3,523.4,,0.001,0.001,274.088,0.059,0.021,0.0137,4614.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-23",9,8.82,876.02,,0.002,0.001,457.312,0.059,0.036,0.0098,7696.238,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-24",11,8.8,862.25,,0.002,0.001,450.68,0.059,0.038,0.0114,7582.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-25",5,4.78,470.32,,0.001,0.001,245.276,0.059,0.023,0.012,4128.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-26",8,7.05,687.6,,0.002,0.001,360.122,0.059,0.027,0.0106,6058.681,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-27",10,9.78,975.56,,0.003,0.001,507.784,0.059,0.04,0.0099,8544.808,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-28",4,3.28,308.7,,0.001,0.001,160.571,0.059,0.017,0.015,2703.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-29",5,4.02,377,,0.001,0.001,196.036,0.059,0.019,0.0132,3298.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-06-30",6,5.05,487.96,,0.001,0.001,253.435,0.059,0.023,0.0122,4264.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-01",9,6.35,594.54,,0.002,0.001,310.67,0.059,0.03,0.0213,5224.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-02",6,4.8,461.34,,0.001,0.001,240.194,0.059,0.021,0.0145,4041.222,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-03",8,6.75,677.95,,0.002,0.001,351.55,0.059,0.028,0.0108,5915.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-04",10,8.98,893.98,,0.002,0.001,465.548,0.059,0.035,0.0099,7833.402,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-05",10,9.52,941.55,,0.002,0.001,490.588,0.059,0.041,0.0105,8255.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-06",2,1.32,109.08,,0,0.001,58.386,0.059,0.012,0.0195,982.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-07",3,2.32,213.26,,0.001,0.001,112.589,0.059,0.013,0.0163,1894.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-08",4,3.28,315.52,,0.001,0.001,165.789,0.059,0.016,0.014,2790.173,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-09",5,4.35,429.65,,0.001,0.001,223.815,0.059,0.019,0.0138,3767.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-10",3,2.3,216.45,,0.001,0.001,113.96,0.059,0.015,0.0177,1917.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-11",10,9.28,890.96,,0.002,0.001,464.422,0.059,0.035,0.01,7817.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-12",9,8.28,771.48,,0.002,0.001,405.363,0.059,0.033,0.0109,6821.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-17",5,3.79,365.9,,0.001,0.001,191.11,0.059,0.019,0.0136,3214.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-18",6,5.1,458.37,,0.001,0.001,242.446,0.059,0.029,0.0167,4077.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-21",6,5.05,479.31,,0.001,0.001,251.84,0.0592,0.027,0.0127,4239.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-22",5,4.28,416.16,,0.001,0.001,217.492,0.059,0.024,0.0136,3660.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-23",2,1.28,106.72,,0,0.001,56.904,0.059,0.015,0.024,958.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-24",6,5.53,530.69,,0.001,0.001,278.724,0.059,0.029,0.013,4690.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-25",6,5.28,521.27,,0.001,0.001,272.196,0.059,0.025,0.0132,4579.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-26",10,9.03,907.72,,0.002,0.001,472.25,0.059,0.036,0.0103,7946.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-27",8,7.53,740.16,,0.002,0.001,385.844,0.059,0.034,0.0111,6493.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-28",6,5.3,521.57,,0.001,0.001,271.578,0.059,0.024,0.012,4569.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-29",7,6.28,616.11,,0.002,0.001,321.343,0.059,0.026,0.0113,5406.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-30",9,8.3,788,,0.002,0.001,413.798,0.059,0.036,0.0104,6962.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-02",6,4.78,403.76,,0.001,0.001,216.731,0.059,0.018,0.024,3646.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-03",6,4.28,356.91,,0.001,0.001,192.093,0.059,0.016,0.0247,3232.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-04",3,2.02,183,,0,0.001,97.288,0.059,0.012,0.016,1637.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-05",2,1.53,129.51,,0,0.001,69.3,0.059,0.011,0.022,1166.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-07",4,3.28,315.52,,0.001,0.001,163.92,0.059,0.018,0.0153,2756.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-08",4,3.28,314.24,,0.001,0.001,163.965,0.059,0.016,0.0143,2757.569,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-09",5,4.58,441.65,,0.001,0.001,229.777,0.059,0.022,0.0118,3866.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-10",7,6.25,596.95,,0.002,0.001,309.715,0.059,0.026,0.0114,5211.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-11",4,3.28,316.52,,0.001,0.001,164.481,0.059,0.017,0.0148,2767.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-12",10,8.98,882.05,,0.002,0.001,457.642,0.059,0.037,0.01,7699.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-13",15,14.35,1448.85,,0.004,0.001,747.79,0.059,0.052,0.0105,12581.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-14",15,13.73,1357.92,,0.004,0.001,705.674,0.0591,0.05,0.0092,11876.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-15",19,18.28,1790.89,,0.005,0.001,929.703,0.059,0.061,0.0084,15642.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-16",22,19.53,1905.12,,0.005,0.001,986.478,0.059,0.067,0.0124,16599.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-17",24,23.13,2039.86,,0.006,0.001,1090.462,0.059,0.069,0.0113,18352.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-18",24,23.9,2199.4,,0.006,0.001,1160.43,0.059,0.07,0.0071,19526.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-19",13,12.02,1066.61,,0.003,0.001,564.524,0.059,0.041,0.0106,9498.971,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-20",9,6.58,362.21,,0.001,0.001,216.441,0.0593,0.021,0.0251,3642.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-21",9,6.82,567.68,,0.002,0.001,303.204,0.0591,0.028,0.016,5102.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-22",9,8.27,807.03,,0.002,0.001,419.479,0.059,0.032,0.0106,7057.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-23",6,3.11,266.49,,0.001,0.001,141.213,0.059,0.018,0.027,2375.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-24",11,9.78,897.94,,0.002,0.001,469.173,0.0591,0.036,0.01,7894.144,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-25",6,4.05,307.22,,0.001,0.001,166.891,0.059,0.019,0.0272,2808.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-26",6,4.57,396.34,,0.001,0.001,209.378,0.059,0.026,0.0303,3523.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-27",6,3.56,186.88,,0.001,0.001,112.671,0.0595,0.013,0.0335,1895.169,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-28",6,4.52,305.6,,0.001,0.001,170.166,0.059,0.02,0.0162,2864.361,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-03",4,2.55,231.35,,0.001,0.001,121.19,0.059,0.012,0.0318,2040.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-04",8,6.88,633.38,,0.002,0.001,332.464,0.059,0.033,0.017,5594.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-05",9,8.03,711.38,,0.002,0.001,376.589,0.0591,0.027,0.0187,6336.699,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-06",10,9.93,928.47,,0.002,0.001,486.704,0.059,0.037,0.0095,8190.037,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-07",10,8.9,841.4,,0.002,0.001,440.99,0.059,0.031,0.0112,7421.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-08",5,4.01,371.21,,0.001,0.001,195.033,0.059,0.017,0.0276,3283.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-09",2,1.23,85.5,,0,0.001,47.352,0.059,0.008,0.032,796.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-11",5,3.93,319.78,,0.001,0.001,171.306,0.059,0.025,0.016,2882.877,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-12",4,3.57,343.1,,0.001,0.001,178.421,0.059,0.018,0.015,3002.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-13",5,4.78,456.76,,0.001,0.001,238.296,0.059,0.023,0.0122,4009.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-14",5,4.57,445.71,,0.001,0.001,232.485,0.059,0.023,0.0122,3912.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-15",5,3.81,334.33,,0.001,0.001,177.408,0.059,0.025,0.0172,2985.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-16",5,4.27,409.21,,0.001,0.001,214.415,0.059,0.02,0.0132,3607.501,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-17",8,6.61,641.28,,0.002,0.001,336.626,0.059,0.034,0.0159,5664.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-18",4,2.97,237.36,,0.001,0.001,127.081,0.059,0.014,0.014,2138.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-19",5,4.28,412.39,,0.001,0.001,213.901,0.059,0.021,0.014,3600.099,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-20",6,5.53,535.92,,0.001,0.001,277.725,0.059,0.025,0.0125,4671.259,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-21",4,3.3,275.8,,0.001,0.001,146.678,0.059,0.015,0.015,2466.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-22",5,4.28,345.45,,0.001,0.001,187.039,0.059,0.017,0.0134,3145.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-23",4,3.03,239.75,,0.001,0.001,130.327,0.059,0.014,0.015,2193.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-24",2,1.28,85.07,,0,0.001,47.787,0.059,0.009,0.022,804.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-27",4,3,258.25,,0.001,0.001,137.24,0.059,0.014,0.019,2310.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-28",6,4.85,404.54,,0.001,0.001,216.722,0.059,0.025,0.014,3648.167,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-29",9,7.78,748.09,,0.002,0.001,390.574,0.059,0.03,0.019,6571.857,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-09-30",11,10.27,1002.17,,0.003,0.001,522.85,0.059,0.038,0.0113,8798.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-01",8,7.05,672.32,,0.002,0.001,354.961,0.059,0.029,0.011,5971.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-02",5,4.53,432.92,,0.001,0.001,229.251,0.059,0.024,0.013,3857.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-03",4,3.27,314.3,,0.001,0.001,165.877,0.059,0.017,0.015,2791.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-04",5,4.03,396.38,,0.001,0.001,209.706,0.059,0.019,0.0162,3530.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-05",10,9,919.05,,0.002,0.001,481.445,0.059,0.035,0.0123,8100.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-07",9,7.32,683.46,,0.002,0.001,357.246,0.0591,0.037,0.0177,6010.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-08",2,1.58,108.12,,0,0.001,58.844,0.059,0.011,0.0235,991.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-10",3,2.28,172.88,,0,0.001,92.632,0.059,0.012,0.024,1557.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-12",2,1.28,78.79,,0,0.001,44.442,0.059,0.008,0.0235,748.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-13",3,1.78,138.89,,0,0.001,74.256,0.059,0.011,0.0437,1250.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-14",5,3.58,275.98,,0.001,0.001,148.614,0.059,0.013,0.0272,2501.236,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-15",11,9.78,951.5,,0.002,0.001,488.695,0.0591,0.038,0.0176,8222.494,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-16",5,4.78,463.32,,0.001,0.001,238.168,0.059,0.025,0.0134,4008.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-17",4,3.52,326.52,,0.001,0.001,168.798,0.059,0.017,0.0145,2842.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-18",6,4.51,408.45,,0.001,0.001,212.129,0.0592,0.02,0.028,3570.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-23",5,3.93,193.42,,0.001,0.001,118.915,0.0594,0.018,0.022,2000.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-24",3,2.52,208.76,,0.001,0.001,109.924,0.059,0.013,0.0173,1849.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-25",6,5.5,504.2,,0.001,0.001,262.204,0.059,0.024,0.013,4411.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-26",4,3.3,321.85,,0.001,0.001,166.175,0.059,0.02,0.017,2795.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-27",10,8.41,834.27,,0.002,0.001,428.581,0.059,0.042,0.0147,7212.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-28",7,5.83,551.57,,0.001,0.001,285.126,0.059,0.038,0.0169,4796.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-29",4,3.3,321.2,,0.001,0.001,167.235,0.059,0.019,0.0158,2813.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-30",5,2.69,172.89,,0,0.001,97.756,0.0592,0.018,0.0346,1645.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-10-31",4,3.01,251.66,,0.001,0.001,134.482,0.0593,0.016,0.0155,2262.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-01",6,5.28,532.04,,0.001,0.001,274.785,0.059,0.026,0.013,4624.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-02",12,10.31,1037.61,,0.003,0.001,535.414,0.0591,0.052,0.0122,9009.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-03",9,8.08,797.67,,0.002,0.001,411.165,0.059,0.044,0.014,6921.457,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-04",11,10.53,1080.24,,0.003,0.001,554.446,0.059,0.043,0.0106,9326.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-05",12,10.83,1076.41,,0.003,0.001,552.625,0.059,0.053,0.0121,9297.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-06",8,6.3,564.39,,0.001,0.001,293.781,0.059,0.023,0.0203,4943.679,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-07",3,1.28,66.43,,0,0.001,40.003,0.059,0.008,0.0427,672.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-08",9,8.15,733.5,,0.002,0.001,380.865,0.059,0.031,0.0202,6408.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-09",16,14.68,1402.17,,0.004,0.001,727.7,0.0591,0.053,0.0094,12241.562,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-10",11,9.53,942.58,,0.002,0.001,482.756,0.059,0.047,0.014,8121.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-11",11,9.54,920.01,,0.002,0.001,473.396,0.059,0.044,0.013,7965.183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-12",7,6.38,613.1,,0.002,0.001,315.332,0.059,0.039,0.0159,5306.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-13",10,7.56,558.39,,0.002,0.001,303.778,0.059,0.03,0.0211,5112.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-14",3,1.78,131.74,,0,0.001,71.24,0.059,0.011,0.0233,1199.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-15",6,5.51,490.32,,0.001,0.001,255.631,0.059,0.022,0.013,4302.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-16",11,7.56,653.36,,0.002,0.001,343.215,0.0592,0.031,0.027,5774.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-17",9,7.06,673.71,,0.002,0.001,347.95,0.0591,0.037,0.0132,5854.227,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-18",12,7.79,549.33,,0.002,0.001,301.718,0.0592,0.036,0.0274,5078.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-19",5,4.03,373.58,,0.001,0.001,192.608,0.059,0.021,0.0148,3242.767,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-20",7,5.99,561.62,,0.001,0.001,290.443,0.059,0.037,0.0167,4888.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-21",7,6,561.54,,0.001,0.001,292.388,0.059,0.026,0.0123,4918.662,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-22",6,5.09,418.56,,0.001,0.001,223.709,0.059,0.021,0.0135,3764.194,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-23",5,4.03,322.59,,0.001,0.001,172.931,0.059,0.017,0.0166,2909.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-24",12,10.81,1041.28,,0.003,0.001,542.058,0.059,0.046,0.0123,9120.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-25",10,7.6,679.9,,0.002,0.001,357.805,0.0591,0.035,0.0154,6019.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-26",5,3.08,246.09,,0.001,0.001,132.703,0.0594,0.021,0.023,2232.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-27",4,3.28,267.44,,0.001,0.001,142.811,0.059,0.017,0.0163,2403.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-28",6,5.05,491.15,,0.001,0.001,254.289,0.059,0.023,0.0153,4280.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-29",8,7.28,708.92,,0.002,0.001,368.039,0.059,0.03,0.0115,6191.182,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-11-30",8,7.01,681.5,,0.002,0.001,353.609,0.059,0.04,0.014,5949.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-01",13,11.99,1182.64,,0.003,0.001,610.554,0.059,0.053,0.0117,10271.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-02",12,10.85,1077.44,,0.003,0.001,554.236,0.059,0.048,0.0121,9325.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-03",12,11.18,1127.92,,0.003,0.001,578.412,0.059,0.052,0.0119,9733.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-04",16,14.33,1439.19,,0.004,0.001,738.779,0.059,0.059,0.0108,12430.689,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-05",13,10.46,1017.16,,0.003,0.001,525.524,0.059,0.046,0.0176,8843.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-06",8,7.28,716.06,,0.002,0.001,368.976,0.059,0.029,0.0113,6208.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-07",13,11.56,1135.18,,0.003,0.001,585.248,0.059,0.05,0.0119,9849.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-08",11,10.2,1000.96,,0.003,0.001,516.339,0.059,0.048,0.0126,8690.451,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-09",15,12.69,1234.91,,0.003,0.001,635.092,0.059,0.07,0.0149,10687.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-10",13,11.35,1096.42,,0.003,0.001,565.664,0.059,0.049,0.0131,9517.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-11",19,17.7,1742.47,,0.005,0.001,897.03,0.0591,0.071,0.0099,15095.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-12",1,0.63,52.29,,0,0.001,27.72,0.059,0.002,0.007,466.137,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-13",24,23.13,2235.07,,0.006,0.001,1157.463,0.059,0.079,0.0117,19475.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-14",18,17.3,1649.14,,0.004,0.001,855.236,0.059,0.058,0.0088,14390.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-15",16,14.36,1370.17,,0.004,0.001,711.492,0.059,0.053,0.0104,11972.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-16",19,18.28,1866.11,,0.005,0.001,955.707,0.059,0.062,0.0083,16082.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-17",5,3.43,303.46,,0.001,0.001,158.985,0.0592,0.018,0.0142,2675.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-18",8,7.48,739.04,,0.002,0.001,380.684,0.059,0.029,0.0114,6405.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-19",4,2.44,192.18,,0.001,0.001,103.594,0.059,0.026,0.0243,1742.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-20",7,4.81,450.65,,0.001,0.001,234.921,0.059,0.031,0.0283,3953.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-21",8,6.53,631.07,,0.002,0.001,328.309,0.059,0.037,0.0159,5523.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-22",8,6.08,586.76,,0.002,0.001,304.672,0.059,0.036,0.0155,5126.678,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-23",9,7.35,716.17,,0.002,0.001,372.354,0.059,0.042,0.0152,6265.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-24",4,3.3,320.87,,0.001,0.001,164.921,0.059,0.02,0.0168,2775.967,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-25",4,3.3,307.26,,0.001,0.001,159.577,0.059,0.018,0.0155,2685.891,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-26",1,0.27,3.51,,0,0.001,3.618,0.06,0.001,0.02,60.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-27",10,8.6,844.44,,0.002,0.001,435.565,0.059,0.044,0.0128,7329.993,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-28",17,15.85,1546.59,,0.004,0.001,797.313,0.059,0.061,0.01,13416.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-29",6,4.38,403.41,,0.001,0.001,208.809,0.059,0.029,0.0178,3514.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"2",,"2020-12-31",7,6.1,568.79,,0.001,0.001,295.073,0.059,0.035,0.0159,4965.741,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-02",3,2.02,144.71,,0,0.001,79.961,0.0593,0.01,0.0237,1344.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-09",6,4.53,453.31,,0.001,0.001,235.232,0.0592,0.023,0.0262,3959.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-10",3,2.78,262.66,,0.001,0.001,138.382,0.059,0.021,0.019,2329.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-13",6,5.27,533.22,,0.001,0.001,275.639,0.059,0.024,0.0127,4639.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-14",3,1.78,162.28,,0,0.001,85.47,0.0593,0.014,0.019,1438.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-15",6,5.29,522.5,,0.001,0.001,272.182,0.0592,0.023,0.0127,4579.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-16",8,6.83,639.71,,0.002,0.001,336.406,0.0591,0.039,0.0139,5659.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-17",8,7.09,664.7,,0.002,0.001,349.823,0.059,0.04,0.0141,5887.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-18",5,4.52,399.76,,0.001,0.001,212.29,0.059,0.021,0.014,3571.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-19",7,6.28,608.44,,0.002,0.001,317.2,0.059,0.032,0.0121,5338.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-20",10,8.78,834.18,,0.002,0.001,438.654,0.059,0.039,0.0123,7380.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-23",3,2.34,211.55,,0.001,0.001,112.931,0.059,0.016,0.02,1899.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-25",7,6.8,691.9,,0.002,0.001,361.41,0.059,0.034,0.0119,6081.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-27",2,1.55,135.48,,0,0.001,72.013,0.059,0.016,0.0235,1212.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-28",3,2.28,170.55,,0,0.001,94.199,0.059,0.014,0.0183,1584.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-29",10,8.83,886.94,,0.002,0.001,460.219,0.059,0.046,0.0131,7745.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-30",3,2.5,222.8,,0.001,0.001,117.71,0.059,0.015,0.019,1982.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-01",3,2.28,196.62,,0.001,0.001,104.817,0.059,0.015,0.02,1765.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-03",4,3.05,267.62,,0.001,0.001,141.901,0.059,0.032,0.0265,2387.653,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-04",9,7.03,658.53,,0.002,0.001,344.963,0.059,0.037,0.0178,5805.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-07",3,2.25,210.05,,0.001,0.001,110.3,0.059,0.015,0.0193,1855.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-08",6,5.28,490.42,,0.001,0.001,258.47,0.059,0.022,0.0153,4349.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-10",3,1.26,69.68,,0,0.001,41.612,0.059,0.01,0.0487,700.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-11",10,8.13,782.43,,0.002,0.001,408.338,0.059,0.037,0.0169,6869.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-12",9,7.58,721.98,,0.002,0.001,378.226,0.059,0.041,0.0141,6365.053,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-13",9,7.81,746.07,,0.002,0.001,390.957,0.059,0.043,0.0141,6579.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-14",8,6.75,650.91,,0.002,0.001,339.265,0.059,0.037,0.02,5710.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-16",6,5.27,470.68,,0.001,0.001,250.104,0.059,0.022,0.013,4208.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-17",3,1.78,152.91,,0,0.001,81.322,0.0593,0.013,0.02,1368.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-18",7,5.35,509.72,,0.001,0.001,266.417,0.059,0.031,0.0191,4482.793,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-19",9,7.39,711.2,,0.002,0.001,371.816,0.059,0.037,0.0159,6256.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-20",1,0.15,0,,0,0.001,1.11,0.06,0.001,0.137,18.615,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-21",9,8.15,801.79,,0.002,0.001,417.212,0.059,0.045,0.0131,7020.963,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-24",9,7.8,737.99,,0.002,0.001,387.691,0.059,0.04,0.0137,6525.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-25",5,4.29,414.11,,0.001,0.001,217.584,0.059,0.02,0.0138,3662.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-26",12,9.46,899.48,,0.002,0.001,474.24,0.059,0.051,0.0215,7979.077,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-27",5,4.57,417.1,,0.001,0.001,220.449,0.059,0.021,0.0136,3709.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-01",6,5.3,528.31,,0.001,0.001,272.048,0.059,0.026,0.0137,4575.993,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-02",10,9.08,838.48,,0.002,0.001,437.801,0.059,0.043,0.0137,7366.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-03",10,8.58,839.11,,0.002,0.001,434.217,0.059,0.044,0.0133,7307.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-04",6,5.52,545.64,,0.001,0.001,283.378,0.059,0.024,0.0125,4767.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-05",8,7.11,685.56,,0.002,0.001,356.933,0.059,0.036,0.0146,6006.479,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-06",9,6.85,612.67,,0.002,0.001,330.894,0.0591,0.031,0.0226,5567.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-07",2,1.27,98.92,,0,0.001,54.741,0.059,0.011,0.0235,921.238,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-08",5,4.09,403.11,,0.001,0.001,214.575,0.059,0.022,0.0142,3611.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-09",10,8.02,793.32,,0.002,0.001,422.813,0.059,0.038,0.0152,7112.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-10",11,10.05,1016.54,,0.003,0.001,538.51,0.059,0.051,0.0125,9061.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-11",10,8.83,868.61,,0.002,0.001,462.065,0.059,0.042,0.013,7775.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-12",1,0.02,0,,0,0,0.136,0.06,0,0.001,2.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-13",1,0.17,0,,0,0.001,1.326,0.059,0.001,0.126,22.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-14",4,3.1,309.5,,0.001,0.001,160.53,0.059,0.012,0.0105,2702.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-16",1,0.2,0,,0,0.001,1.54,0.06,0.002,0.136,25.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-27",2,0.55,26.32,,0,0.001,15.977,0.0595,0.003,0.0315,269.107,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-01",12,9.41,884.07,,0.002,0.001,459.015,0.0591,0.034,0.0246,7723.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-02",3,2.17,211.4,,0.001,0.001,109.173,0.0593,0.006,0.0077,1838.229,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-04",4,3.59,340.99,,0.001,0.001,176.762,0.059,0.019,0.0153,2975.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-06",3,2.3,198.75,,0.001,0.001,106.009,0.059,0.013,0.0177,1783.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-07",3,2.3,210.01,,0.001,0.001,111.421,0.059,0.014,0.0177,1875.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-08",4,3.6,344.38,,0.001,0.001,181.77,0.059,0.02,0.0133,3059.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-10",3,1.73,138.68,,0,0.001,74.889,0.059,0.01,0.0243,1260.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-11",5,4.52,442.92,,0.001,0.001,231.718,0.059,0.022,0.0138,3899.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-12",5,4.52,438.68,,0.001,0.001,229.648,0.059,0.02,0.014,3865.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-13",7,4.9,404.95,,0.001,0.001,217.85,0.0591,0.019,0.0151,3665.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-14",4,3.28,289.56,,0.001,0.001,153.478,0.059,0.016,0.0153,2582.581,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-15",4,2.79,242.75,,0.001,0.001,129.376,0.059,0.015,0.0198,2177.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-16",7,6.05,586.4,,0.002,0.001,307.804,0.059,0.025,0.0117,5179.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-26",6,4.8,377.86,,0.001,0.001,207.705,0.0592,0.017,0.023,3494.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-27",6,5.05,465.33,,0.001,0.001,247.553,0.059,0.019,0.014,4166.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-28",4,2.28,185.05,,0.001,0.001,100.603,0.0593,0.011,0.0325,1693.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-29",2,1.28,82.1,,0,0.001,46.602,0.059,0.007,0.029,784.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-05-31",5,3.8,261.8,,0.001,0.001,149.3,0.059,0.015,0.0164,2510.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-01",5,3.13,236.82,,0.001,0.001,129.993,0.0592,0.015,0.0378,2187.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-02",5,4.3,413.47,,0.001,0.001,218.686,0.059,0.022,0.014,3679.122,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-03",12,8.74,819.01,,0.002,0.0009,433.756,0.0591,0.049,0.029,7300.258,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-04",10,8.1,740.09,,0.002,0.001,392.164,0.0591,0.038,0.0205,6599.663,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-08",5,4.28,421.89,,0.001,0.001,219.511,0.059,0.021,0.0134,3693.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-09",7,6.26,625.69,,0.002,0.001,326.025,0.059,0.027,0.0119,5485.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-10",13,10.48,1039.87,,0.003,0.001,543.711,0.0591,0.053,0.0176,9149.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-11",9,7.03,663.5,,0.002,0.001,349.837,0.059,0.035,0.0137,5885.789,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-12",5,3.78,330.82,,0.001,0.001,175.9,0.059,0.017,0.014,2960.071,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-13",3,2.53,236.92,,0.001,0.001,124.969,0.059,0.018,0.0173,2102.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-14",5,4.28,414.36,,0.001,0.001,218.108,0.059,0.023,0.0128,3669.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-15",6,4.77,402.97,,0.001,0.001,217.474,0.0592,0.026,0.0152,3660.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-16",10,6.67,556.48,,0.002,0.001,299.873,0.0592,0.035,0.0246,5045.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-17",4,3.09,296.07,,0.001,0.001,155.549,0.0593,0.014,0.0318,2617.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-18",4,3.23,312.23,,0.001,0.001,164.095,0.059,0.016,0.0143,2761.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-19",5,4.05,390.43,,0.001,0.001,205.037,0.059,0.019,0.0128,3448.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-20",5,4.3,412.66,,0.001,0.001,217.71,0.059,0.022,0.0124,3663.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-21",5,4.05,393.48,,0.001,0.001,208.182,0.059,0.019,0.0128,3501.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-22",6,5.3,523.48,,0.001,0.001,276.024,0.059,0.021,0.0137,4644.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-23",8,7.55,757.98,,0.002,0.001,398.1,0.059,0.031,0.0109,6698.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-24",11,10.02,1015,,0.003,0.001,531.902,0.059,0.039,0.0099,8952.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-25",4,3.03,293.25,,0.001,0.001,154.721,0.059,0.016,0.0338,2603.961,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-26",9,8.03,788.13,,0.002,0.001,416.611,0.059,0.032,0.0108,7009.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-27",10,9.78,978.56,,0.003,0.001,512.85,0.059,0.042,0.0102,8629.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-28",4,3.28,309.76,,0.001,0.001,162.637,0.059,0.017,0.015,2736.547,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-29",5,4.02,377.4,,0.001,0.001,198.128,0.059,0.018,0.0128,3335.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-06-30",6,5.05,480.07,,0.001,0.001,252.462,0.059,0.021,0.0118,4249.471,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-01",6,5.07,478.98,,0.001,0.001,251.259,0.059,0.022,0.0118,4227.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-02",5,3.8,372.8,,0.001,0.001,195.116,0.059,0.018,0.0158,3283.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-03",8,6.77,678.72,,0.002,0.001,354.73,0.059,0.027,0.0108,5968.739,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-04",6,5.04,506.02,,0.001,0.001,265.19,0.059,0.023,0.012,4461.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-05",8,7.28,717.52,,0.002,0.001,375.765,0.059,0.03,0.0109,6324.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-06",2,1.27,106.33,,0,0.001,57.564,0.059,0.014,0.0225,969.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-07",3,2.3,212.9,,0.001,0.001,113.335,0.059,0.014,0.017,1907.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-08",4,3.28,317.15,,0.001,0.001,167.555,0.059,0.017,0.0143,2818.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-09",6,5.25,522.8,,0.001,0.001,273.86,0.059,0.022,0.0152,4608.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-10",5,4.53,443.06,,0.001,0.001,233.761,0.059,0.023,0.0128,3933.521,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-11",10,9.28,892.98,,0.002,0.001,469.771,0.059,0.035,0.01,7906.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-12",9,8.28,773.13,,0.002,0.001,409.975,0.059,0.031,0.0103,6896.411,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-14",3,2.53,241.98,,0.001,0.001,127.886,0.059,0.018,0.017,2151.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-17",3,2.54,233.26,,0.001,0.001,124.066,0.059,0.014,0.017,2087.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-18",7,6.55,640.38,,0.002,0.001,337.94,0.059,0.029,0.0109,5686.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-21",4,3.05,270.14,,0.001,0.001,144.029,0.0593,0.019,0.0148,2424.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-22",5,4.28,418.56,,0.001,0.001,219.72,0.059,0.023,0.0128,3696.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-23",2,1.3,107.3,,0,0.001,57.966,0.059,0.014,0.022,974.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-24",6,5.53,534.34,,0.001,0.001,282.025,0.059,0.027,0.0122,4746.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-25",6,5.28,522.92,,0.001,0.001,274.908,0.059,0.023,0.012,4625.871,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-26",11,10.03,1002.06,,0.003,0.001,525.026,0.059,0.039,0.01,8831.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-27",8,7.53,742.04,,0.002,0.001,389.578,0.059,0.034,0.011,6555.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-28",6,5.3,522.61,,0.001,0.001,275.191,0.059,0.023,0.012,4630.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-29",6,5.3,525.8,,0.001,0.001,276.69,0.059,0.024,0.012,4656.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-30",9,8.3,787.42,,0.002,0.001,416.348,0.0591,0.035,0.0102,7004.178,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-02",6,4.8,405.12,,0.001,0.001,218.32,0.059,0.019,0.0243,3673.489,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-03",6,4.28,352.89,,0.001,0.001,189.659,0.0592,0.016,0.0255,3191.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-05",2,1.53,128.88,,0,0.001,69.741,0.059,0.011,0.023,1173.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-06",3,2.25,180.7,,0,0.001,98.315,0.059,0.015,0.017,1655.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-07",4,3.3,314.86,,0.001,0.001,162.261,0.059,0.017,0.015,2730.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-08",5,3.6,325.8,,0.001,0.001,173.2,0.0592,0.025,0.0358,2914.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-09",5,4.58,444.58,,0.001,0.001,233.297,0.059,0.023,0.012,3923.972,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-10",8,7.25,685.9,,0.002,0.001,361.52,0.059,0.029,0.0109,6084.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-12",10,9,889.75,,0.002,0.001,466.88,0.0591,0.039,0.0106,7854.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-13",12,10.1,975.69,,0.003,0.001,512.373,0.0591,0.042,0.0153,8619.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-14",14,13.63,1360.92,,0.004,0.001,715.428,0.059,0.05,0.0092,12035.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-15",19,18.28,1811.89,,0.005,0.001,949.802,0.059,0.065,0.0086,15983.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-16",19,17.95,1776.49,,0.005,0.001,928.673,0.059,0.064,0.0088,15625.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-17",21,20.65,1790.3,,0.005,0.001,971.05,0.059,0.069,0.0087,16342.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-18",24,23.9,2194.3,,0.006,0.001,1166.74,0.059,0.074,0.0075,19637.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-19",13,12.02,1070.61,,0.003,0.001,571.769,0.059,0.041,0.0109,9622.018,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-20",9,6.58,364.08,,0.001,0.001,218.599,0.0591,0.021,0.0266,3677.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-21",7,5.53,469.61,,0.001,0.001,252.42,0.0591,0.021,0.0133,4247.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-22",9,8.27,812.3,,0.002,0.001,426.792,0.059,0.036,0.0117,7181.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-23",7,4.11,369.91,,0.001,0.001,196.018,0.059,0.024,0.0266,3298.789,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-24",10,8.78,806.57,,0.002,0.001,425.963,0.059,0.033,0.0104,7166.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-25",6,4.07,309.57,,0.001,0.001,169.546,0.059,0.02,0.0288,2853.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-26",8,5.78,459.84,,0.001,0.001,250.547,0.0591,0.025,0.0235,4216.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-27",6,2.58,122.41,,0,0.001,76.785,0.0593,0.013,0.045,1291.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-28",5,3.5,199.6,,0.001,0.001,127.286,0.059,0.017,0.0184,2141.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-03",4,2.55,233.2,,0.001,0.001,124.11,0.059,0.013,0.034,2087.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-04",8,6.88,639.66,,0.002,0.001,338.859,0.059,0.036,0.0184,5701.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-05",9,8.13,737.38,,0.002,0.001,391.935,0.0591,0.03,0.0197,6594.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-06",11,10.85,1021.28,,0.003,0.001,540.541,0.059,0.043,0.0098,9095.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-07",10,8.92,850.47,,0.002,0.001,449.88,0.059,0.034,0.0119,7568.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-08",5,4.01,371.32,,0.001,0.001,196.941,0.059,0.019,0.03,3313.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-09",2,1.23,86.16,,0,0.001,48.264,0.059,0.008,0.033,812.469,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-11",5,3.93,319.86,,0.001,0.001,173.05,0.059,0.025,0.0164,2911.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-12",3,2.57,237.18,,0.001,0.001,125.273,0.059,0.015,0.0177,2108.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-13",4,3.52,330.38,,0.001,0.001,175.244,0.059,0.018,0.015,2949.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-14",5,4.57,446.61,,0.001,0.001,236.107,0.059,0.026,0.0136,3972.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-15",5,4.78,455.86,,0.001,0.001,241.64,0.059,0.025,0.0134,4066.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-16",5,4.25,410.45,,0.001,0.001,217.375,0.059,0.022,0.0142,3657.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-17",5,4.27,414.05,,0.001,0.001,220.216,0.059,0.026,0.0142,3706.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-18",3,2.07,151.08,,0,0.001,83.473,0.059,0.013,0.0183,1404.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-19",5,4.28,413.39,,0.001,0.001,216.973,0.059,0.021,0.0142,3650.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-20",6,5.53,536.92,,0.001,0.001,281.659,0.059,0.025,0.0127,4739.727,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-21",4,3.3,275.8,,0.001,0.001,148.829,0.059,0.016,0.0153,2503.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-22",5,4.28,342.85,,0.001,0.001,187.815,0.059,0.017,0.0132,3159.929,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-23",3,1.8,120.01,,0,0.001,68.093,0.059,0.011,0.0187,1146.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-24",3,2.53,185.58,,0.001,0.001,102.858,0.0593,0.012,0.0177,1728.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-25",2,1.3,85.3,,0,0.001,48.62,0.059,0.008,0.0295,818.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-28",7,5.83,478.6,,0.001,0.001,260.191,0.059,0.029,0.0137,4376.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-29",9,7.78,747.44,,0.002,0.001,395.017,0.059,0.031,0.0198,6645.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-09-30",11,10.27,1006.43,,0.003,0.001,530.679,0.059,0.037,0.0111,8929.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-01",8,7.05,670.32,,0.002,0.001,358.544,0.059,0.031,0.0116,6033.077,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-02",5,4.53,436.68,,0.001,0.001,233.538,0.059,0.026,0.0136,3929.801,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-03",4,3.27,314.92,,0.001,0.001,168.308,0.059,0.018,0.0153,2832.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-04",5,4.03,398.76,,0.001,0.001,213.617,0.059,0.02,0.0168,3593.787,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-05",10,9,917.8,,0.002,0.001,487.575,0.059,0.038,0.0128,8203.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-07",5,3.67,320.91,,0.001,0.001,170.926,0.059,0.029,0.0236,2875.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-08",2,1.58,109.02,,0,0.001,59.702,0.059,0.011,0.024,1004.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-12",2,1.28,73.63,,0,0.001,42.762,0.0595,0.009,0.0245,719.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-13",3,1.78,139.54,,0,0.001,75.307,0.0593,0.011,0.0467,1266.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-14",5,3.58,277.56,,0.001,0.001,150.562,0.0592,0.013,0.0288,2533.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-15",11,9.8,954.12,,0.003,0.001,496.114,0.059,0.037,0.0182,8348.409,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-16",5,4.78,462.22,,0.001,0.001,241.082,0.059,0.026,0.0138,4056.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-17",4,3.52,330.76,,0.001,0.001,173.258,0.059,0.018,0.015,2914.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-18",5,4.28,408.17,,0.001,0.001,212.535,0.059,0.021,0.0138,3575.769,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-19",8,6.26,615.05,,0.002,0.001,320.188,0.059,0.034,0.015,5388.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-20",4,3.05,288.16,,0.001,0.001,150.761,0.059,0.016,0.015,2536.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-21",8,6.78,639.16,,0.002,0.001,334.692,0.059,0.039,0.0148,5632.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-22",6,4.83,453.01,,0.001,0.001,237.036,0.059,0.032,0.0167,3989.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-23",4,3.3,314.9,,0.001,0.001,165.03,0.059,0.017,0.0193,2776.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-24",3,2.49,207.44,,0.001,0.001,110.634,0.059,0.015,0.0193,1860.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-25",6,5.5,503.34,,0.001,0.001,265.122,0.059,0.024,0.013,4459.858,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-26",4,3.3,314.9,,0.001,0.001,165.115,0.059,0.019,0.0168,2777.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-27",10,8.76,861.53,,0.002,0.001,448.506,0.059,0.047,0.0141,7548.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-28",7,5.81,544.67,,0.001,0.001,285.992,0.059,0.036,0.0161,4811.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-29",4,3.3,319.2,,0.001,0.001,168.195,0.059,0.018,0.0155,2829.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-30",6,5.6,505.6,,0.001,0.001,270.07,0.059,0.025,0.0122,4543.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-10-31",4,3.01,252.04,,0.001,0.001,135.986,0.059,0.016,0.016,2288.777,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-01",2,0.28,13,,0,0.001,7.881,0.0595,0.006,0.0475,132.741,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-02",12,10.33,1037.01,,0.003,0.001,541.61,0.0591,0.042,0.0101,9111.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-03",7,6.28,633.87,,0.002,0.001,330.298,0.059,0.027,0.0117,5557.963,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-04",11,10.53,1081.87,,0.003,0.001,562.017,0.059,0.042,0.0103,9459.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-05",13,11.83,1183.77,,0.003,0.001,615.075,0.059,0.054,0.0114,10349.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-06",6,5.03,447.38,,0.001,0.001,235.878,0.0592,0.026,0.0128,3968.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-08",8,7.15,646,,0.002,0.001,338.695,0.059,0.027,0.0211,5699.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-09",5,4.12,349,,0.001,0.001,186.736,0.0592,0.011,0.0078,3142.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-20",11,7.61,598.72,,0.002,0.001,326.536,0.059,0.032,0.0216,5496.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-21",7,6.01,564.52,,0.002,0.001,298.546,0.059,0.027,0.0129,5021.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-22",6,5.09,422.4,,0.001,0.001,228.289,0.059,0.021,0.0135,3841.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-23",8,6.08,466.97,,0.001,0.001,255.554,0.0591,0.03,0.0179,4301.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-24",12,10.81,1022.16,,0.003,0.001,540.55,0.0591,0.046,0.0124,9093.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-25",11,8.6,772.65,,0.002,0.001,412.195,0.059,0.038,0.0149,6937.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-26",7,4.81,438.29,,0.001,0.001,232.616,0.059,0.028,0.0213,3915.489,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-27",5,4.28,364.65,,0.001,0.001,195.804,0.059,0.02,0.0146,3293.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-28",7,6.05,592.79,,0.002,0.001,311.838,0.059,0.025,0.0134,5246.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-29",8,7.28,707.55,,0.002,0.001,372.133,0.059,0.03,0.0114,6261.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-11-30",9,8.05,788.12,,0.002,0.001,413.43,0.059,0.045,0.0133,6955.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-01",13,12.03,1182.95,,0.003,0.001,618.842,0.059,0.055,0.012,10413.624,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-02",8,7.55,757.25,,0.002,0.001,395.756,0.059,0.032,0.0115,6658.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-03",12,11.2,1131.75,,0.003,0.001,587.418,0.059,0.053,0.0119,9884.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-04",16,14.35,1435.52,,0.004,0.001,746.478,0.059,0.059,0.011,12558.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-05",12,9.46,910.1,,0.002,0.001,477.164,0.0591,0.042,0.0188,8030.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-06",8,7.3,717.87,,0.002,0.001,374.478,0.059,0.03,0.0115,6300.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-07",13,11.56,1135.21,,0.003,0.001,593.217,0.059,0.051,0.0121,9981.575,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-08",11,9.83,954.08,,0.003,0.001,499.881,0.059,0.047,0.0125,8409.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-09",17,15.18,1473.49,,0.004,0.001,771.223,0.059,0.063,0.0165,12977.429,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-10",13,11.36,1095.93,,0.003,0.001,572.646,0.059,0.05,0.0134,9636.543,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-11",19,17.7,1738.6,,0.005,0.001,908.776,0.0591,0.071,0.01,15290.323,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-12",5,3.23,231.69,,0.001,0.001,128.139,0.059,0.02,0.0184,2156.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-13",24,23.15,2230.85,,0.006,0.001,1172.675,0.059,0.078,0.0118,19730.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-14",18,16.93,1604.43,,0.004,0.001,843.895,0.059,0.055,0.0084,14200.127,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-15",18,16.75,1618.38,,0.004,0.001,852.13,0.059,0.058,0.0094,14338.373,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-16",20,19.28,1981.37,,0.005,0.001,1028.073,0.059,0.066,0.0083,17299.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-17",5,3.43,303.46,,0.001,0.001,161.521,0.0592,0.019,0.0152,2717.227,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-18",10,9.3,901.3,,0.002,0.001,472.318,0.059,0.046,0.0134,7949.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-19",4,2.44,194.46,,0.001,0.001,106.058,0.0593,0.028,0.0258,1783.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-20",9,7.04,680.93,,0.002,0.001,357.448,0.059,0.039,0.0174,6015.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-21",10,8.55,837.33,,0.002,0.001,440.555,0.059,0.048,0.0156,7413.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-22",8,6.1,584.8,,0.002,0.001,308.005,0.059,0.038,0.0166,5182.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-23",10,8.41,826.11,,0.002,0.001,435.094,0.059,0.048,0.0149,7320.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-24",4,3.3,320.87,,0.001,0.001,167.702,0.059,0.021,0.018,2821.437,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-25",4,3.3,308.26,,0.001,0.001,162.35,0.059,0.02,0.0175,2731.951,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-26",2,1.35,85.34,,0,0.001,48.973,0.0595,0.013,0.0235,823.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-27",11,9.56,932.02,,0.002,0.001,487.4,0.059,0.048,0.0131,8203.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-28",15,14.15,1381.36,,0.004,0.001,722.153,0.059,0.057,0.0107,12150.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-29",8,6.35,607.3,,0.002,0.001,317.521,0.059,0.037,0.016,5342.977,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"3",,"2020-12-31",7,6.09,567.68,,0.002,0.001,299.057,0.0591,0.036,0.0169,5030.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-27",1,0.52,27.04,,0,0.001,16.432,0.059,0.007,0.05,276.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-01",8,6.42,570.03,,0.002,0.001,306.867,0.059,0.022,0.0108,5163.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-02",3,2.05,179.33,,0,0.001,97.059,0.059,0.014,0.0193,1633.281,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-03",5,4.05,367.72,,0.001,0.001,197.17,0.059,0.035,0.0228,3318.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-04",11,9.07,853.85,,0.002,0.001,453.845,0.059,0.046,0.0166,7636.657,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-05",6,4.31,396.89,,0.001,0.001,211.365,0.059,0.032,0.0185,3556.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-07",4,3.25,317.95,,0.001,0.001,168.185,0.059,0.019,0.0168,2829.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-08",9,7.37,685.67,,0.002,0.001,366.018,0.059,0.041,0.0167,6160.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-09",7,5.78,554.92,,0.001,0.001,294.436,0.059,0.027,0.0153,4955.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-10",10,7.56,647.95,,0.002,0.001,352.166,0.059,0.037,0.0257,5924.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-11",10,8.33,796.72,,0.002,0.001,422.277,0.059,0.043,0.0165,7106.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-12",9,7.58,723.98,,0.002,0.001,384.196,0.059,0.044,0.0146,6464.781,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-13",10,8.81,843.35,,0.002,0.001,447.356,0.059,0.048,0.0137,7528.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-14",9,7.51,710.93,,0.002,0.001,377.321,0.059,0.042,0.0143,6347.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-15",3,2.05,191.1,,0.001,0.001,102.02,0.059,0.013,0.023,1716.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-16",5,4.27,388.53,,0.001,0.001,208.477,0.059,0.021,0.0146,3508.537,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-17",3,1.77,154.1,,0,0.001,82.83,0.059,0.014,0.0197,1394.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-18",8,6.58,638.41,,0.002,0.001,337.171,0.059,0.036,0.0169,5672.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-19",9,7.39,711.1,,0.002,0.001,376.943,0.059,0.041,0.0172,6344.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-20",6,5,447.25,,0.001,0.001,241.115,0.059,0.022,0.0172,4057.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-21",8,7.15,696.14,,0.002,0.001,367.555,0.059,0.043,0.014,6184.999,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-24",9,7.8,735.67,,0.002,0.001,391.951,0.059,0.043,0.0144,6595.237,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-25",8,6.57,601.71,,0.002,0.001,323.38,0.059,0.039,0.0154,5441.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-26",11,8.08,771.91,,0.002,0.001,412.224,0.0591,0.04,0.0215,6936.057,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-27",7,5.6,489.1,,0.001,0.001,264.63,0.059,0.029,0.0176,4452.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-01",7,6.55,654.81,,0.002,0.001,342.209,0.059,0.034,0.0126,5757.909,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-02",10,9.08,838.48,,0.002,0.001,444.362,0.059,0.047,0.0145,7476.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-03",9,7.33,709.26,,0.002,0.001,373.749,0.059,0.043,0.0143,6287.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-04",4,3.52,332.46,,0.001,0.001,176.552,0.059,0.019,0.016,2972.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-05",9,8.13,789.08,,0.002,0.001,417.553,0.059,0.041,0.0139,7024.413,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-06",9,6.85,609.13,,0.002,0.001,332.068,0.059,0.035,0.0228,5587.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-07",8,7.03,680.2,,0.002,0.001,369.197,0.059,0.041,0.0136,6212.481,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-08",9,7.56,740.26,,0.002,0.001,401.311,0.059,0.043,0.0139,6751.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-09",10,8.04,793.84,,0.002,0.001,429.802,0.059,0.041,0.0157,7231.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-10",13,12.07,1196.82,,0.003,0.001,647.957,0.059,0.059,0.012,10903.941,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-11",11,9.68,949.06,,0.003,0.001,514.153,0.059,0.054,0.0145,8648.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-12",24,22.8,2365.9,,0.006,0.001,1273.505,0.059,0.089,0.0121,21430.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-13",17,15.92,1654.67,,0.005,0.001,891.033,0.059,0.065,0.0093,14994.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-16",13,10.87,1097.08,,0.003,0.001,574.001,0.059,0.053,0.0175,9657.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-17",7,4.33,372.4,,0.001,0.001,201.935,0.0591,0.028,0.0289,3397.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-18",3,2.55,240.12,,0.001,0.001,128.137,0.059,0.017,0.02,2156.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-19",2,1.55,133.51,,0,0.001,71.828,0.059,0.016,0.024,1208.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-20",6,4.81,419.74,,0.001,0.001,224.868,0.059,0.029,0.0185,3784.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-23",3,2.03,160.56,,0,0.001,87.437,0.059,0.013,0.0197,1471.236,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-25",1,0.22,0,,0,0.001,1.628,0.059,0.002,0.133,27.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-26",5,4.3,430.06,,0.001,0.001,224.126,0.059,0.017,0.0098,3771.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-08",6,5.05,518.12,,0.001,0.001,270.124,0.059,0.025,0.016,4545.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-15",1,0.03,0,,0,0.001,0.204,0.06,0,0.074,3.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-16",2,0.7,40.28,,0,0.001,23.569,0.0595,0.005,0.033,396.178,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-22",2,1.82,167.44,,0,0.001,89.094,0.059,0.008,0.0105,1500.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-28",9,8.05,832,,0.002,0.001,435.39,0.059,0.031,0.0178,7325.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-29",2,1.25,117.5,,0,0.001,62,0.059,0.004,0.0075,1043.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-01",6,5.72,520.96,,0.001,0.001,279.1,0.0592,0.026,0.0117,4694.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-03",5,4.05,349.26,,0.001,0.001,188.147,0.059,0.02,0.0142,3165.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-04",4,3.59,346.75,,0.001,0.001,182.403,0.059,0.021,0.016,3069.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-05",2,1.3,76.05,,0,0.001,45.37,0.059,0.009,0.024,762.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-06",3,2.3,196.12,,0.001,0.001,106.15,0.059,0.014,0.018,1786.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-07",3,2.3,210.01,,0.001,0.001,112.571,0.059,0.015,0.018,1895.132,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-08",7,6.11,577.29,,0.002,0.001,307.263,0.059,0.036,0.0139,5171.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-09",7,6.51,632.01,,0.002,0.001,334.822,0.059,0.028,0.0116,5635.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-11",6,4.67,442.92,,0.001,0.001,235.41,0.059,0.025,0.0337,3961.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-12",3,2.68,257.6,,0.001,0.001,136.664,0.059,0.017,0.02,2300.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-13",8,6.13,506.87,,0.001,0.001,276.662,0.059,0.024,0.0145,4654.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-14",6,4.57,398.81,,0.001,0.001,213.578,0.059,0.026,0.0195,3595.552,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-15",5,3.8,346.9,,0.001,0.001,185.662,0.059,0.018,0.0164,3124.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-16",7,6.04,586.02,,0.002,0.001,310.69,0.059,0.026,0.0119,5227.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-17",4,3.28,323.54,,0.001,0.001,171.256,0.059,0.017,0.0183,2882.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-26",7,6.03,504.88,,0.001,0.001,276.716,0.0593,0.022,0.0223,4657.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-27",6,5.05,462.33,,0.001,0.001,249.858,0.0592,0.02,0.0143,4202.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-28",4,2.28,185.33,,0.001,0.001,102.028,0.059,0.011,0.0338,1715.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-29",2,1.28,82.1,,0,0.001,47.37,0.059,0.007,0.028,797.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-30",3,1.3,57.71,,0,0.001,37.712,0.059,0.007,0.0413,635.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-05-31",5,3.53,252.94,,0.001,0.001,144.158,0.059,0.015,0.0164,2425.597,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-01",10,8.8,789.23,,0.002,0.001,425.364,0.059,0.04,0.0124,7159.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-02",4,3.29,311.27,,0.001,0.001,166.394,0.059,0.018,0.0148,2800.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-03",13,12.29,1083.26,,0.003,0.001,589.399,0.059,0.044,0.0098,9918.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-04",12,10.62,904.2,,0.002,0.001,490.729,0.059,0.046,0.0118,8254.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-07",3,1.58,143.98,,0,0.001,76.878,0.059,0.012,0.0407,1292.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-08",7,6.13,589.02,,0.002,0.001,310.42,0.059,0.041,0.0166,5224.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-09",8,7.3,729.23,,0.002,0.001,383.224,0.059,0.034,0.0123,6449.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-10",8,6.73,595.03,,0.002,0.001,318.747,0.059,0.03,0.021,5363.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-11",9,7.03,659.5,,0.002,0.001,351.36,0.0591,0.037,0.0144,5912.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-12",5,3.78,329.82,,0.001,0.001,177.833,0.059,0.019,0.0152,2992.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-13",3,2.53,235.92,,0.001,0.001,125.834,0.059,0.021,0.0197,2117.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-14",5,4.28,414.36,,0.001,0.001,220.16,0.059,0.026,0.0142,3703.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-15",7,5.79,514.69,,0.001,0.001,278.15,0.059,0.031,0.0143,4680.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-16",20,17.83,1197.66,,0.003,0.001,692.959,0.0592,0.059,0.0145,11656.009,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-17",4,3.09,295.32,,0.001,0.001,157.003,0.059,0.017,0.0333,2641.433,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-18",5,4.23,419.53,,0.001,0.001,221.804,0.059,0.021,0.014,3733.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-19",5,4.05,390.43,,0.001,0.001,206.836,0.059,0.022,0.0146,3480.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-20",5,4.3,412.66,,0.001,0.001,219.73,0.059,0.025,0.0142,3697.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-21",5,4.05,391.06,,0.001,0.001,208.687,0.059,0.021,0.0144,3510.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-22",6,5.3,524.4,,0.001,0.001,278.744,0.059,0.024,0.0158,4690.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-23",8,7.57,749.48,,0.002,0.001,398.736,0.059,0.037,0.0114,6709.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-24",10,7.8,765.5,,0.002,0.001,407.05,0.059,0.041,0.0136,6853.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-25",5,4.8,472.2,,0.001,0.001,250.868,0.059,0.027,0.0136,4223.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-26",9,8.03,791.5,,0.002,0.001,421.648,0.059,0.035,0.0117,7094.353,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-27",11,10.78,1082.48,,0.003,0.001,574.108,0.059,0.048,0.0105,9660.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-28",4,3.28,314.65,,0.001,0.001,166.722,0.059,0.019,0.0163,2805.018,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-29",5,4.02,376.4,,0.001,0.001,199.936,0.0592,0.021,0.0144,3362.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-06-30",6,5.05,475.02,,0.001,0.001,252.378,0.059,0.024,0.0133,4247.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-01",9,6.35,586.14,,0.002,0.001,311.799,0.059,0.035,0.0236,5246.483,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-02",6,4.8,461.38,,0.001,0.001,244.662,0.059,0.022,0.0162,4115.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-03",6,5.5,549,,0.001,0.001,289.34,0.059,0.026,0.0132,4871.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-04",10,9,901.16,,0.002,0.001,477.096,0.059,0.035,0.0104,8028.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-05",9,8.34,820.89,,0.002,0.001,434.57,0.059,0.038,0.0117,7313.471,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-06",2,1.32,109.08,,0,0.001,59.754,0.059,0.016,0.024,1005.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-07",3,2.3,212.9,,0.001,0.001,114.485,0.059,0.016,0.0193,1926.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-08",4,3.28,317.15,,0.001,0.001,169.067,0.059,0.019,0.0165,2844.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-09",5,4.33,430.83,,0.001,0.001,228.199,0.059,0.021,0.0162,3839.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-10",3,2.3,217.1,,0.001,0.001,116.325,0.059,0.017,0.0197,1957.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-11",10,9.28,892.98,,0.002,0.001,474.511,0.059,0.038,0.0107,7985.333,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-12",9,8.28,773.76,,0.002,0.001,414.141,0.059,0.034,0.0113,6967.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-17",3,2.54,234.48,,0.001,0.001,126.21,0.059,0.016,0.0197,2122.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-18",7,6.55,645.93,,0.002,0.001,344.356,0.059,0.034,0.0124,5793.552,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-21",4,2.65,201.26,,0.001,0.001,112.025,0.0593,0.02,0.026,1885.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-22",5,4.28,418.96,,0.001,0.001,222.344,0.059,0.025,0.0136,3741.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-23",3,1.65,115.7,,0,0.001,65.371,0.059,0.018,0.039,1100.439,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-24",6,5.53,539.22,,0.001,0.001,287.194,0.059,0.03,0.0132,4830.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-25",6,5.28,527.55,,0.001,0.001,278.846,0.059,0.027,0.0137,4692.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-26",12,11.03,1101.89,,0.003,0.001,583.191,0.059,0.045,0.0103,9813.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-27",8,7.53,747.92,,0.002,0.001,397.489,0.059,0.036,0.0113,6689.421,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-28",6,5.3,528.24,,0.001,0.001,280.682,0.059,0.026,0.0133,4721.923,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-29",7,6.28,621.76,,0.002,0.001,329.82,0.059,0.029,0.0126,5550.003,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-30",10,9.3,931.26,,0.002,0.001,493.606,0.059,0.043,0.0108,8305.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-02",6,4.8,396.92,,0.001,0.001,217.97,0.059,0.02,0.0253,3668.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-03",3,2.08,153.62,,0,0.001,85.928,0.0593,0.015,0.0173,1446.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-04",4,3.27,314.5,,0.001,0.001,168.64,0.059,0.019,0.0163,2837.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-05",4,3.28,318.43,,0.001,0.001,169.857,0.059,0.019,0.0165,2860.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-07",4,3.3,317.53,,0.001,0.001,167.815,0.059,0.019,0.0165,2824.303,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-08",4,3.28,317.52,,0.001,0.001,168.653,0.059,0.02,0.0165,2839.077,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-09",5,4.58,447.23,,0.001,0.001,237.117,0.059,0.026,0.0136,3990.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-10",8,7.25,701.15,,0.002,0.001,371.095,0.059,0.031,0.0116,6242.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-12",10,8.98,897.86,,0.002,0.001,474.328,0.059,0.04,0.0109,7983.781,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-13",15,14.35,1457.35,,0.004,0.001,767.465,0.059,0.053,0.0106,12915.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-14",15,13.73,1375.92,,0.004,0.001,728.74,0.059,0.053,0.0098,12262.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-15",19,18.3,1837.53,,0.005,0.001,970.246,0.059,0.066,0.0086,16327.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-16",22,20.47,2074.08,,0.006,0.001,1090.393,0.059,0.077,0.009,18347.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-17",21,20.65,1808.3,,0.005,0.001,989.365,0.059,0.071,0.0089,16648.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-18",24,23.9,2207.2,,0.006,0.001,1186.85,0.059,0.076,0.0076,19972.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-19",13,12.02,1071.61,,0.003,0.001,576.588,0.059,0.043,0.0115,9703.101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-20",9,7.3,431.12,,0.001,0.001,257.136,0.0591,0.023,0.0199,4326.003,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-21",7,5.53,471.61,,0.001,0.001,256.063,0.059,0.023,0.015,4308.487,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-22",9,8.27,822.92,,0.002,0.001,436.157,0.059,0.038,0.0121,7340.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-23",7,5.28,519.2,,0.001,0.001,274.32,0.059,0.026,0.0249,4614.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-24",10,8.78,811.57,,0.002,0.001,432.726,0.059,0.037,0.0114,7281.361,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-25",9,7.78,707.59,,0.002,0.001,378.445,0.0591,0.031,0.0196,6367.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-26",8,5.83,478.06,,0.001,0.001,261.5,0.0593,0.025,0.0236,4401.257,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-27",7,3.58,216.44,,0.001,0.001,127.284,0.0591,0.017,0.039,2141.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-28",6,4.52,313.33,,0.001,0.001,177.151,0.0592,0.022,0.0178,2979.233,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-01",2,1.3,111.8,,0,0.001,60.32,0.059,0.014,0.028,1015.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-03",4,2.55,236.75,,0.001,0.001,126.635,0.059,0.015,0.034,2129.735,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-04",8,7.58,740.74,,0.002,0.001,393.293,0.059,0.038,0.0116,6619.613,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-05",9,8.13,744.25,,0.002,0.001,398.822,0.059,0.031,0.0198,6711.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-06",12,11.85,1135.21,,0.003,0.001,603.868,0.059,0.047,0.0097,10161.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-07",8,7.2,689.35,,0.002,0.001,367.475,0.059,0.033,0.0119,6182.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-08",6,5.03,442.76,,0.001,0.001,239.331,0.059,0.023,0.0263,4026.967,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-11",5,3.93,319.29,,0.001,0.001,174.565,0.0592,0.027,0.017,2936.909,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-12",3,2.57,236.53,,0.001,0.001,126.171,0.059,0.017,0.02,2122.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-13",4,3.52,329.38,,0.001,0.001,176.128,0.059,0.02,0.0165,2964.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-14",5,4.57,452.28,,0.001,0.001,240.516,0.059,0.028,0.0142,4046.927,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-15",5,3.83,338.44,,0.001,0.001,182.876,0.059,0.029,0.019,3077.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-16",5,4.25,411.45,,0.001,0.001,219.435,0.059,0.023,0.015,3693.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-17",5,4.27,418.45,,0.001,0.001,222.798,0.059,0.028,0.015,3747.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-18",3,2.05,150.82,,0,0.001,83.909,0.059,0.013,0.019,1412.749,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-19",5,4.28,411.39,,0.001,0.001,217.557,0.059,0.023,0.015,3661.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-20",6,5.53,536.92,,0.001,0.001,283.565,0.059,0.027,0.0135,4771.989,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-21",4,3.3,277.8,,0.001,0.001,150.249,0.059,0.017,0.0168,2527.333,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-22",5,4.27,340.79,,0.001,0.001,188.183,0.059,0.019,0.0146,3167.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-23",3,1.8,120.01,,0,0.001,68.805,0.059,0.011,0.0197,1156.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-24",3,2.53,182.59,,0.001,0.001,102.514,0.059,0.013,0.019,1724.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-25",2,1.3,85.3,,0,0.001,49.18,0.059,0.009,0.0325,827.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-28",7,5.83,475.73,,0.001,0.001,261,0.0591,0.03,0.0146,4392.233,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-29",9,7.78,746.44,,0.002,0.001,396.782,0.059,0.032,0.0197,6679.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-09-30",11,10.27,1007.43,,0.003,0.001,534.744,0.059,0.04,0.012,8999.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-01",8,7.05,662.27,,0.002,0.001,357.875,0.059,0.032,0.0121,6023.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-02",5,4.53,437.33,,0.001,0.001,236.026,0.059,0.027,0.0142,3970.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-03",4,3.27,317.57,,0.001,0.001,170.973,0.059,0.019,0.0165,2877.131,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-04",5,4.03,399.76,,0.001,0.001,214.812,0.059,0.021,0.018,3615.222,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-05",9,7.58,767.86,,0.002,0.001,411.177,0.059,0.033,0.014,6920.276,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-01",2,0.28,2.7,,0,0.001,3.58,0.0595,0.004,0.125,60.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-02",8,3.28,135.18,,0,0.001,88.494,0.0591,0.028,0.0571,1489.553,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-03",6,5.31,531.04,,0.001,0.001,277.744,0.059,0.024,0.012,4673.727,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-04",14,12.79,1293.15,,0.003,0.001,677.206,0.059,0.061,0.0118,11395.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-05",12,10.88,1078.48,,0.003,0.001,563.864,0.059,0.051,0.0115,9489.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-06",6,5.03,448.28,,0.001,0.001,236.854,0.059,0.027,0.013,3987.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-07",3,1.28,86.58,,0,0.001,48.896,0.0593,0.009,0.043,822.503,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-08",18,16.1,1184.85,,0.003,0.001,659.014,0.059,0.054,0.0153,11092.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-09",14,12.68,1177.52,,0.003,0.001,623.618,0.059,0.046,0.0095,10491.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-10",11,9.55,950.52,,0.002,0.001,495.1,0.059,0.049,0.0139,8330.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-11",11,9.54,921.66,,0.002,0.001,482.586,0.059,0.046,0.0136,8119.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-12",9,8.31,809.48,,0.002,0.001,423.105,0.059,0.047,0.0143,7117.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-13",10,7.56,547.78,,0.002,0.001,304.986,0.059,0.031,0.0209,5131.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-14",6,5.05,432.65,,0.001,0.001,231.695,0.059,0.023,0.0137,3899.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-15",6,5.51,485.69,,0.001,0.001,258,0.059,0.024,0.0137,4343.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-16",14,11.99,998.58,,0.003,0.001,537.598,0.0591,0.05,0.0178,9048.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-17",9,7.06,674.36,,0.002,0.001,354.042,0.059,0.039,0.0141,5956.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-18",12,9.24,704.54,,0.002,0.001,387.477,0.0592,0.039,0.0199,6520.127,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-19",5,4.03,367.85,,0.001,0.001,193.464,0.0592,0.022,0.0154,3254.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-20",9,7.24,692.07,,0.002,0.001,363.468,0.0591,0.043,0.0154,6115.899,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-21",7,6.01,562.52,,0.002,0.001,298.148,0.059,0.028,0.0133,5017.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-22",6,5.09,420.4,,0.001,0.001,228.307,0.059,0.023,0.0142,3840.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-23",9,7.06,549.22,,0.002,0.001,300.887,0.059,0.034,0.0173,5065.461,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-24",11,9.81,906.74,,0.002,0.001,483.113,0.059,0.045,0.0136,8126.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-25",11,8.58,767.99,,0.002,0.001,411.638,0.059,0.04,0.0154,6925.641,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-26",7,4.81,434.89,,0.001,0.001,232.553,0.059,0.029,0.0223,3912.653,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-27",3,2.28,187.44,,0.001,0.001,101.618,0.059,0.015,0.0207,1709.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-28",7,6.05,592.21,,0.002,0.001,312.132,0.059,0.026,0.0143,5253.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-29",7,6.3,608.6,,0.002,0.001,321.445,0.059,0.028,0.0124,5409.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-11-30",9,8.03,789.1,,0.002,0.001,416.328,0.059,0.046,0.0136,7006.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-01",13,11.99,1184.63,,0.003,0.001,621.07,0.059,0.057,0.0123,10450.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-02",12,10.83,1080.09,,0.003,0.001,565.867,0.059,0.051,0.0128,9523.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-03",12,11.18,1131.47,,0.003,0.001,590.145,0.059,0.054,0.0123,9932.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-04",16,14.33,1441.32,,0.004,0.001,752.514,0.0591,0.061,0.0113,12663.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-05",13,10.46,1011.9,,0.003,0.001,531.722,0.0591,0.045,0.0178,8948.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-06",8,7.28,722.69,,0.002,0.001,377.487,0.059,0.032,0.0123,6351.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-07",13,11.56,1138.12,,0.003,0.001,595.99,0.059,0.054,0.0126,10026.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-08",11,9.83,958.85,,0.003,0.001,503.478,0.059,0.048,0.0128,8472.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-09",15,13.08,1284.71,,0.003,0.001,672.528,0.059,0.055,0.0166,11317.141,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-10",13,11.35,1098.1,,0.003,0.001,575.37,0.059,0.053,0.0139,9682.503,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-11",19,17.7,1739.87,,0.005,0.001,911.814,0.059,0.075,0.0105,15342.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-12",6,4.23,314.35,,0.001,0.001,173.616,0.059,0.024,0.0173,2921.171,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-13",22,20.94,1982.81,,0.005,0.001,1047.295,0.059,0.086,0.0136,17624.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-14",17,15.93,1512.43,,0.004,0.001,796.944,0.059,0.055,0.0089,13411.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-15",15,13.73,1332.04,,0.004,0.001,702.34,0.059,0.056,0.0123,11821.587,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-16",19,17.91,1818.4,,0.005,0.001,947.762,0.059,0.063,0.0085,15952.071,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-17",4,2.8,247.34,,0.001,0.001,131.455,0.059,0.018,0.0178,2211.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-18",10,9.28,903,,0.002,0.001,474.492,0.059,0.047,0.0136,7986.668,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-19",4,2.44,193.88,,0.001,0.001,106.274,0.059,0.028,0.0255,1787.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-20",8,6.04,578.46,,0.002,0.001,305.249,0.059,0.037,0.0194,5134.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-21",12,10.96,1038.78,,0.003,0.001,553.503,0.059,0.054,0.0133,9311.869,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-22",12,10.18,930.67,,0.003,0.001,498.8,0.0591,0.049,0.0136,8391.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-23",9,7.4,727.41,,0.002,0.001,384.508,0.059,0.045,0.0156,6468.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-24",3,2.3,213.65,,0.001,0.001,112.773,0.059,0.018,0.0217,1897.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-25",5,4.3,415.52,,0.001,0.001,218.743,0.059,0.024,0.0156,3681.289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-26",2,1.35,85.34,,0,0.001,49.243,0.059,0.012,0.0225,828.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-27",11,9.55,936.41,,0.002,0.001,490.923,0.059,0.051,0.0135,8262.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-28",15,13.53,1307.07,,0.003,0.001,686.334,0.059,0.061,0.0146,11548.959,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-29",8,6.35,613.65,,0.002,0.001,321.055,0.059,0.038,0.0161,5403.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Panoche Energy Center",56803,"4",,"2020-12-31",7,6.09,566.26,,0.002,0.001,299.251,0.059,0.037,0.017,5035.961,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-08",5,3.24,83.55,,0,0.001,55.691,0.0596,0.006,0.0266,936.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-14",2,1.42,30.44,,0,0.001,21.442,0.0595,0.003,0.0145,360.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-17",2,1.64,36.9,,0,0.001,25.174,0.059,0.003,0.014,423.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-03",4,2.67,60.25,,0,0.001,41.55,0.0595,0.006,0.0168,698.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-04",5,2.37,79.04,,0,0.001,49.427,0.0592,0.009,0.0334,831.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-05",3,1.2,28.4,,0,0.001,19.4,0.0593,0.004,0.0617,326.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-25",4,2.72,94.84,,0,0.001,58.284,0.0593,0.005,0.0115,981.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-01",3,1.7,37.3,,0,0.001,26.27,0.0593,0.004,0.0233,441.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-12",4,3.21,138.71,,0,0.001,81.985,0.0593,0.008,0.0125,1378.849,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-16",7,5.48,142.08,,0,0.001,94.346,0.0596,0.008,0.0124,1585.122,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-17",6,5,147.7,,0,0.001,94.965,0.0595,0.009,0.0112,1597.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-21",2,1.21,26.18,,0,0.001,18.733,0.059,0.004,0.0275,315.062,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-28",2,1.41,31.02,,0,0.001,21.573,0.059,0.003,0.015,362.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-06",2,1.18,25.61,,0,0.001,18.067,0.0595,0.002,0.016,304.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-09",2,1.23,25.31,,0,0.001,18.154,0.0595,0.003,0.0165,305.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-10",4,2.41,51.91,,0,0.001,36.722,0.0595,0.005,0.0148,617.273,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-12",3,1.71,43.27,,0,0.001,28.775,0.0597,0.003,0.011,484.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-14",5,3.16,71.18,,0,0.001,49.282,0.0594,0.006,0.0166,828.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-16",3,1.21,26.82,,0,0.001,18.801,0.06,0.002,0.0297,315.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-18",4,2.46,54.49,,0,0.001,37.773,0.0593,0.005,0.0158,634.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-19",2,1.21,26.18,,0,0.001,18.667,0.059,0.003,0.025,313.929,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-20",4,3.53,123.41,,0,0.001,75.727,0.0593,0.008,0.0125,1273.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-21",7,5.62,179.73,,0.001,0.001,113.572,0.0594,0.011,0.0137,1909.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-22",3,1.79,45.29,,0,0.001,30.486,0.0597,0.006,0.019,512.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-23",5,2.32,50,,0,0.001,35.504,0.0592,0.004,0.018,597.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-24",5,3.44,113.8,,0,0.001,71.754,0.0592,0.006,0.0114,1208.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-25",2,1.16,25.52,,0,0.001,17.98,0.0595,0.002,0.0145,302.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-26",2,1.43,31.46,,0,0.001,22.248,0.0595,0.003,0.015,373.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-27",2,1.18,27.2,,0,0.001,18.902,0.0595,0.002,0.0115,317.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-28",2,1.16,25.03,,0,0.001,17.834,0.059,0.003,0.024,300.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-04-30",2,1.23,26.66,,0,0.001,18.788,0.0595,0.002,0.0145,315.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-02",3,1.71,55.35,,0,0.001,34.893,0.059,0.004,0.042,587.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-03",3,1.71,46.26,,0,0.001,30.467,0.0593,0.003,0.032,511.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-04",5,3.95,118.46,,0,0.001,76.044,0.059,0.01,0.018,1281.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-05",3,1.98,45.58,,0,0.001,31.716,0.059,0.004,0.0173,534.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-06",5,2.67,58.8,,0,0.001,41.479,0.0592,0.006,0.0192,698.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-08",6,5.17,177.75,,0.001,0.001,110.443,0.0597,0.01,0.0115,1856.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-09",2,1.1,26.2,,0,0.001,17.62,0.059,0.002,0.032,296.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-10",4,1.24,25.8,,0,0.001,18.248,0.0593,0.002,0.0225,307.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-11",4,3.68,124.06,,0,0.001,76.803,0.0593,0.007,0.0115,1292.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-16",4,3.23,95.66,,0,0.001,62.151,0.0593,0.006,0.0145,1044.783,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-21",3,2.21,51.24,,0,0.001,35.752,0.0593,0.005,0.0267,601.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-27",5,3.46,87.54,,0,0.001,59.456,0.0598,0.006,0.0126,999.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-07",1,0.13,0,,0,0.001,0.806,0.059,0.001,0.139,13.611,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-11",8,6.2,293.2,,0.001,0.001,169.57,0.0593,0.015,0.0173,2853.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-12",8,6.23,294.89,,0.001,0.001,170.555,0.0593,0.016,0.0251,2867.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-15",12,10.3,497.9,,0.001,0.001,288.4,0.0594,0.025,0.022,4851.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-16",10,8.23,399.76,,0.001,0.001,230.334,0.0592,0.02,0.0217,3873.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-19",10,8.2,394.5,,0.001,0.001,226.47,0.0593,0.02,0.0289,3811.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-29",4,2.72,124.28,,0,0.001,72.336,0.0593,0.007,0.026,1216.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-09",2,1.65,45.32,,0,0.001,30.007,0.06,0.004,0.0165,504.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-10",4,3.48,132.18,,0,0.001,80.75,0.0593,0.007,0.0115,1358.497,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-29",3,1.7,46.5,,0,0.001,31.004,0.0597,0.003,0.0253,521.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-30",4,3.05,114.81,,0,0.001,69.912,0.0593,0.005,0.0145,1177.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-07-31",4,3.43,128.86,,0,0.001,78.96,0.0598,0.006,0.01,1326.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-06",2,1.1,45.72,,0,0.001,27.476,0.059,0.003,0.0125,462.273,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-09",2,1.22,26.46,,0,0.001,19.002,0.0595,0.003,0.0255,319.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-12",3,1.97,55.46,,0,0.001,36.464,0.059,0.003,0.011,614.271,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-13",5,4.72,135.38,,0,0.001,88.374,0.0592,0.007,0.0094,1486.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-14",8,7.06,233.5,,0.001,0.001,146.562,0.0594,0.012,0.0108,2464.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-15",6,4.97,168,,0.001,0.001,105.808,0.059,0.008,0.0112,1780.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-16",3,2.22,51.92,,0,0.001,36.078,0.0593,0.003,0.0113,607.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-17",14,12.22,462.54,,0.001,0.001,281.732,0.0594,0.019,0.0144,4738.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-18",8,7.23,250.89,,0.001,0.001,156.751,0.0591,0.012,0.0098,2638.231,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-19",9,7.96,234.51,,0.001,0.001,152.488,0.0593,0.011,0.0129,2565.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-20",4,2.94,107.03,,0,0.001,66.039,0.0593,0.005,0.0098,1110.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-25",3,2.22,53.46,,0,0.001,36.32,0.0593,0.004,0.0133,611.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-27",4,2.68,96.18,,0,0.001,59.73,0.0593,0.005,0.013,1005.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-28",2,1.15,28.55,,0,0.001,19.415,0.059,0.002,0.017,326.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-03",5,3.24,114.64,,0,0.001,71.392,0.0592,0.005,0.017,1201.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-04",4,2.74,84.2,,0,0.001,53.802,0.0593,0.004,0.0135,905.324,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-05",10,8.97,352.21,,0.001,0.001,214.359,0.0592,0.016,0.009,3607.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-06",12,10.47,399.67,,0.001,0.001,245.203,0.0593,0.019,0.0118,4125.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-09",2,1.22,37.4,,0,0.001,24.12,0.059,0.003,0.017,406.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-12",2,0.3,1.68,,0,0.001,2.6,0.0595,0.003,0.0745,43.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-14",5,3.22,100.86,,0,0.001,64.572,0.059,0.005,0.0158,1087.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-16",1,0.42,11.76,,0,0.001,7.77,0.06,0.001,0.017,130.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-18",2,1.11,41.56,,0,0.001,25.583,0.0595,0.003,0.0245,431.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-19",3,2.47,103.21,,0,0.001,60.997,0.0593,0.005,0.0103,1026.537,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-21",1,0.33,11.55,,0,0.001,7.227,0.059,0.002,0.037,121.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-22",3,0.48,9.78,,0,0.001,7.08,0.0593,0.001,0.016,119.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-29",1,0.38,9.88,,0,0.001,6.726,0.059,0.001,0.011,113.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-01",5,3.26,81.86,,0,0.001,56.108,0.0594,0.005,0.0162,943.107,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-02",3,1.25,51.82,,0,0.001,31.201,0.0597,0.003,0.0187,525.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-06",2,1.1,41.73,,0,0.001,25.697,0.0595,0.002,0.0125,432.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-08",1,0.4,10,,0,0.001,6.96,0.059,0.001,0.023,117.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-09",5,2.77,109.84,,0,0.001,66.425,0.0594,0.006,0.0206,1117.471,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-19",2,1.21,36.07,,0,0.001,23.218,0.0595,0.004,0.02,390.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-21",4,2.96,78.54,,0,0.001,52.534,0.0593,0.005,0.015,883.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-29",6,2.81,121.25,,0,0.001,71.973,0.0592,0.008,0.043,1211.397,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-10-31",4,2.23,102.93,,0,0.001,60.577,0.059,0.005,0.0255,1021.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-02",2,1.18,26.04,,0,0.001,18.314,0.059,0.003,0.018,308.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-05",2,0.45,12.9,,0,0.001,8.457,0.0595,0.001,0.009,142.369,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-06",3,1.66,43.76,,0,0.001,28.364,0.0593,0.003,0.0147,477.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-09",2,1.43,37.69,,0,0.001,24.496,0.06,0.004,0.017,411.293,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-10",3,1.91,42.37,,0,0.001,29.023,0.059,0.003,0.015,488.473,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-11",2,1.18,24.31,,0,0.001,17.073,0.059,0.004,0.0295,287.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-17",1,0.45,13.5,,0,0.001,8.685,0.06,0.002,0.023,145.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-01",2,1.23,26.64,,0,0.001,18.339,0.0595,0.003,0.0145,308.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-03",16,15.12,535.2,,0.002,0.001,328.276,0.0592,0.027,0.0166,5526.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-04",1,0.07,0,,0,0.001,0.42,0.06,0,0.022,7.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-11",3,1.42,27.58,,0,0.001,19.65,0.059,0.006,0.064,331.542,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-12",2,1.23,29.61,,0,0.001,20.094,0.059,0.003,0.0185,338.163,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-14",3,2.06,46.67,,0,0.001,31.267,0.0593,0.006,0.021,526.551,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-16",3,2.2,50.24,,0,0.001,34.014,0.0593,0.004,0.0163,572.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-08",7,4.44,113.31,,0,0.001,75.29,0.059,0.009,0.015,1267.899,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-14",2,1.55,33.18,,0,0.001,23.405,0.059,0.002,0.013,394.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-17",2,1.62,36.44,,0,0.001,24.862,0.059,0.003,0.0125,418.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-03",4,2.75,61.93,,0,0.001,42.665,0.0593,0.008,0.02,717.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-04",5,2.42,81.97,,0,0.001,50.831,0.0598,0.008,0.0274,855.123,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-05",3,1.22,28.62,,0,0.001,19.422,0.059,0.004,0.066,327.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-19",2,1.22,26.24,,0,0.001,18.428,0.0595,0.002,0.013,309.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-01",6,3.17,94.08,,0,0.001,60.346,0.059,0.008,0.0205,1016.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-16",14,12.23,378.05,,0.001,0.001,237.882,0.0592,0.018,0.0114,4003.873,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-21",2,1.21,26.18,,0,0.001,18.612,0.059,0.004,0.0245,313.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-06",2,1.22,26.1,,0,0.001,18.237,0.059,0.002,0.0155,307.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-09",2,1.46,32.75,,0,0.001,22.61,0.059,0.003,0.0155,380.883,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-10",2,1.21,26.67,,0,0.001,18.528,0.06,0.002,0.014,311.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-11",2,1.21,26.67,,0,0.001,18.528,0.059,0.002,0.0135,312.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-14",2,1.18,25.39,,0,0.001,17.743,0.059,0.003,0.0205,298.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-16",4,2.44,60.39,,0,0.001,40.693,0.0593,0.006,0.0185,684.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-17",3,2.21,51.67,,0,0.001,34.907,0.059,0.004,0.015,588.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-18",3,1.21,26.95,,0,0.001,18.619,0.059,0.002,0.0313,313.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-19",4,2.42,54.74,,0,0.001,38.082,0.059,0.004,0.013,641.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-20",4,3.53,123.41,,0,0.001,75.374,0.0595,0.007,0.0108,1267.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-21",7,5.62,179.73,,0.001,0.001,112.975,0.0593,0.009,0.01,1900.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-22",3,1.79,45.29,,0,0.001,30.483,0.0593,0.005,0.0153,512.461,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-23",3,1.16,25.72,,0,0.001,17.788,0.059,0.002,0.0207,299.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-24",3,1.98,83.94,,0,0.001,49.78,0.059,0.004,0.01,838.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-25",4,2.81,66.58,,0,0.001,45.645,0.0595,0.004,0.0103,767.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-26",4,3.14,78.68,,0,0.001,52.723,0.059,0.004,0.0095,888.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-28",2,1.16,25.03,,0,0.001,17.751,0.0595,0.002,0.0175,298.503,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-01",4,2.44,76.52,,0,0.001,47.762,0.059,0.004,0.0115,804.541,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-02",4,2.96,92.62,,0,0.001,58.72,0.0595,0.006,0.0125,987.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-03",4,2.95,80.82,,0,0.001,53.092,0.0598,0.006,0.0138,892.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-04",3,2.21,65.62,,0,0.001,41.992,0.0597,0.003,0.01,705.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-05",4,3.2,76.44,,0,0.001,51.872,0.0593,0.004,0.01,872.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-06",5,2.67,58.8,,0,0.001,41.175,0.0594,0.004,0.0152,692.543,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-08",6,5.19,178.55,,0.001,0.001,109.894,0.0593,0.008,0.0093,1848.087,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-09",2,1.12,26.2,,0,0.001,17.636,0.0595,0.002,0.023,296.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-10",4,1.26,25.8,,0,0.001,18.326,0.0593,0.002,0.0185,307.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-11",4,3.68,115.21,,0,0.001,72.389,0.059,0.005,0.009,1218.214,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-16",4,3.23,95.66,,0,0.001,61.765,0.0593,0.005,0.01,1039.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-21",3,2.21,51.24,,0,0.001,35.569,0.0597,0.003,0.0127,597.873,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-27",5,3.46,87.54,,0,0.001,59.094,0.0594,0.005,0.01,994.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-30",3,1.71,39.49,,0,0.001,26.948,0.0597,0.002,0.0113,453.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-03",1,0.1,0,,0,0.001,0.6,0.06,0,0.072,10.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-17",10,8.23,391.76,,0.001,0.001,224.986,0.0594,0.015,0.0117,3784.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-18",10,8.18,390.68,,0.001,0.001,223.794,0.0592,0.015,0.0193,3767.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-07",2,1.18,31.4,,0,0.001,20.942,0.0595,0.002,0.0125,352.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-09",2,1.65,45.32,,0,0.001,29.759,0.0595,0.003,0.011,500.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-10",5,3.71,145.29,,0,0.001,88.156,0.0592,0.008,0.011,1483.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-29",3,1.69,47.98,,0,0.001,30.919,0.0593,0.003,0.0177,520.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-30",4,2.6,114.56,,0,0.001,67.628,0.0595,0.006,0.009,1138.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-07-31",3,2.43,85.29,,0,0.001,52.577,0.0593,0.004,0.0103,884.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-06",2,1.1,45.72,,0,0.001,27.366,0.059,0.003,0.011,461.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-09",2,1.22,26.46,,0,0.001,18.848,0.0595,0.002,0.018,316.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-12",4,2.97,94.16,,0,0.001,59.682,0.0595,0.005,0.01,1002.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-13",5,4.72,131.82,,0,0.001,86.018,0.0594,0.007,0.01,1447.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-14",8,7.07,221,,0.001,0.001,140.448,0.0595,0.011,0.0098,2360.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-15",6,4.97,159.2,,0.001,0.001,101.018,0.0593,0.007,0.0092,1698.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-16",3,2.22,53.49,,0,0.001,36.37,0.0593,0.003,0.011,611.347,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-17",14,12.22,460.66,,0.001,0.001,280.868,0.0592,0.018,0.0101,4728.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-18",7,6.2,188.8,,0.001,0.001,120.42,0.0593,0.008,0.0083,2026.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-19",9,7.96,219.55,,0.001,0.001,142.872,0.0591,0.009,0.0094,2406.977,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-20",5,3.95,155.7,,0,0.001,93.599,0.0592,0.007,0.009,1574.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-25",3,2.22,53.46,,0,0.001,36.096,0.0593,0.003,0.0103,607.562,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-27",5,3.67,118.84,,0,0.001,75.005,0.0592,0.006,0.0106,1262.189,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-28",2,1.15,28.55,,0,0.001,19.275,0.059,0.002,0.012,325.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-03",2,1.08,21.3,,0,0.001,15.894,0.059,0.002,0.0145,267.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-04",4,2.74,84.2,,0,0.001,53.528,0.0593,0.004,0.0133,900.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-05",9,7.68,303.52,,0.001,0.001,183.296,0.0593,0.015,0.0097,3083.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-06",12,10.47,399.67,,0.001,0.001,242.956,0.059,0.02,0.0104,4089.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-14",5,3.22,115.86,,0,0.001,71.162,0.0592,0.006,0.0134,1197.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-18",2,1.11,42.94,,0,0.001,26.274,0.0595,0.003,0.018,441.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-19",3,2.47,106.68,,0,0.001,63.16,0.0597,0.005,0.0103,1061.569,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-01",4,3.05,72.85,,0,0.001,49.705,0.0593,0.005,0.023,836.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-06",2,1.1,40.86,,0,0.001,25.152,0.0595,0.002,0.012,423.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-19",3,2.21,71.62,,0,0.001,44.492,0.059,0.004,0.0113,750.365,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-21",5,3.96,103.92,,0,0.001,69.39,0.0592,0.006,0.0122,1168.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-10-31",4,2.23,103.93,,0,0.001,60.703,0.059,0.005,0.0178,1022.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-02",4,3.16,74.94,,0,0.001,51.106,0.0595,0.005,0.0118,859.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-23",2,0.42,11.97,,0,0.001,7.989,0.0595,0.002,0.021,134.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-01",2,1.23,26.64,,0,0.001,18.741,0.059,0.002,0.0115,316.293,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-03",16,15.1,535.2,,0.002,0.001,329.22,0.0593,0.031,0.0141,5541.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-04",1,0.07,0,,0,0.001,0.455,0.059,0,0.014,7.679,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-05",3,1.68,37.2,,0,0.001,25.996,0.0593,0.003,0.0147,437.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-11",4,3.17,73.17,,0,0.001,50.333,0.059,0.006,0.0165,847.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-12",2,1.23,29.61,,0,0.001,20.316,0.059,0.002,0.013,342.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-14",4,2.95,68.25,,0,0.001,46.808,0.0593,0.006,0.0163,787.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-15",4,2.91,63.44,,0,0.001,44.577,0.0593,0.007,0.0193,749.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-16",4,3.2,73.62,,0,0.001,51.108,0.0593,0.004,0.0108,859.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","Orange Grove Project",56914,"CTG2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-02",2,1.2,34.46,,0,0.001,22.622,0.0595,0.01,0.047,380.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-03",3,1.73,68.9,,0,0.001,41.088,0.059,0.009,0.0337,692.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-08",5,2.38,63.46,,0,0.001,42.099,0.0592,0.015,0.0528,708.107,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-14",2,1.21,28.27,,0,0.001,19.382,0.0595,0.009,0.0475,326.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-17",2,1.22,28.14,,0,0.001,19.43,0.059,0.007,0.043,327.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-25",2,1.23,33.84,,0,0.001,22.44,0.059,0.01,0.0465,378.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-28",2,1.21,27.94,,0,0.001,19.613,0.0595,0.009,0.046,329.571,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-30",4,2.42,61.03,,0,0.001,41.565,0.0595,0.011,0.0355,698.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-01",3,1.21,51.6,,0,0.001,30.123,0.0593,0.011,0.0603,506.103,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-03",3,1.2,37.9,,0,0.001,23.81,0.0593,0.009,0.065,400.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-04",2,1.23,30.23,,0,0.001,20.966,0.059,0.01,0.0455,353.487,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-05",3,1.2,31.08,,0,0.001,20.849,0.0593,0.004,0.0573,351.353,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-10",10,8.23,384.96,,0.001,0.001,223.101,0.0593,0.016,0.0119,3752.907,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-11",13,11.21,534.39,,0.002,0.001,308.742,0.0591,0.03,0.0246,5194.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-16",2,1.15,40.75,,0,0.001,25.18,0.0595,0.01,0.075,423,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-17",1,0.1,0,,0,0.001,0.62,0.06,0,0.032,10.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-25",8,5.95,184.61,,0.001,0.001,119.511,0.059,0.022,0.0269,2012.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-26",5,3.21,80.08,,0,0.001,55.683,0.0592,0.009,0.043,936.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-01",2,1.22,27.66,,0,0.001,19.684,0.0595,0.009,0.0725,330.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-02",2,1.2,27.6,,0,0.001,19.68,0.06,0.003,0.019,330.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-26",2,1.03,23.28,,0,0.001,16.625,0.059,0.007,0.047,279.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-06",2,1.2,33.98,,0,0.001,22.537,0.059,0.01,0.0615,379.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-24",3,1.93,50.31,,0,0.001,34.698,0.059,0.011,0.0373,584.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-01",2,1.2,30,,0,0.001,20.7,0.0595,0.005,0.0305,348.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-05",2,1.2,27.64,,0,0.001,19.634,0.059,0.007,0.0435,330.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-12",3,1.53,66.05,,0,0.001,39.057,0.059,0.01,0.0527,657.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-16",2,1.22,38.56,,0,0.001,24.807,0.0595,0.008,0.051,417.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-21",11,8.42,369.69,,0.001,0.001,221.191,0.0593,0.018,0.0184,3720.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-23",2,1.18,27.52,,0,0.001,19.457,0.059,0.009,0.0495,328.017,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-30",2,1.17,28.11,,0,0.001,19.728,0.0595,0.007,0.038,331.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-10",2,1.2,38.25,,0,0.001,24.909,0.059,0.005,0.0255,419.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-16",2,1.23,28.65,,0,0.001,20,0.059,0.005,0.034,336.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-07",2,1.22,27.18,,0,0.001,20.126,0.059,0.005,0.0345,339.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-10",2,1.18,32.56,,0,0.001,22.352,0.0595,0.005,0.025,375.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-26",2,1.2,27.23,,0,0.001,19.901,0.0595,0.006,0.0515,334.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-29",3,1.2,40.52,,0,0.001,26.132,0.0597,0.01,0.0573,438.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-30",3,2.2,71.18,,0,0.001,46.374,0.0597,0.009,0.0227,779.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-07-31",4,2.7,89.37,,0,0.001,58.45,0.0595,0.009,0.0288,982.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-09",2,1.21,30.49,,0,0.001,21.309,0.0595,0.007,0.0515,358.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-12",4,2.18,53.3,,0,0.001,37.414,0.0595,0.008,0.0495,629.636,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-13",5,3.65,93.6,,0,0.001,64.98,0.0594,0.013,0.0268,1092.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-14",7,5.46,150.8,,0.001,0.001,102.774,0.059,0.018,0.0247,1730.574,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-15",5,4.42,130.79,,0,0.001,86.881,0.0592,0.011,0.0166,1462.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-16",2,1.71,41.09,,0,0.001,28.914,0.0595,0.008,0.031,485.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-17",8,6.55,166,,0.001,0.001,115.895,0.059,0.012,0.0175,1951.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-18",8,7.21,223.29,,0.001,0.001,147.985,0.0596,0.015,0.0138,2487.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-19",10,8.25,343.35,,0.001,0.001,207.29,0.0592,0.019,0.0224,3486.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-20",7,5.59,172.33,,0.001,0.001,112.79,0.0594,0.015,0.0296,1898.709,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-23",1,0.02,0,,0,0,0.05,0.06,0,0,0.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-24",8,6.95,197.36,,0.001,0.001,132.589,0.0595,0.01,0.0105,2228.793,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-25",3,1.45,34.14,,0,0.001,24.314,0.0593,0.006,0.0413,409.647,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-26",3,1.2,27.56,,0,0.001,19.736,0.0593,0.007,0.0567,332.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-27",3,1.22,43.66,,0,0.001,27.182,0.0597,0.009,0.0567,456.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-28",6,4.4,111.08,,0,0.001,77.788,0.0595,0.011,0.0367,1307.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-29",2,1.15,26.44,,0,0.001,18.905,0.059,0.009,0.05,318.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-03",2,1.2,27.64,,0,0.001,19.696,0.0595,0.006,0.034,331.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-04",3,2.13,59.47,,0,0.001,40.297,0.0593,0.007,0.019,677.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-05",11,8.92,288.15,,0.001,0.001,186.786,0.0591,0.02,0.0239,3144.919,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-06",15,12.26,438.5,,0.001,0.001,276.394,0.0591,0.028,0.0217,4652.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-09",6,4.26,144.78,,0,0.001,91.594,0.0593,0.015,0.025,1541.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-19",3,2.05,81.74,,0,0.001,49.373,0.059,0.013,0.0313,831.598,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-09-30",9,7.71,234.57,,0.001,0.001,155.503,0.0593,0.017,0.0163,2615.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-01",8,5.6,146.48,,0.001,0.001,101.285,0.0593,0.016,0.0259,1704.359,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-02",2,1.48,62.12,,0,0.001,37.336,0.059,0.012,0.032,628.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-21",5,3.51,95.19,,0,0.001,64.736,0.0592,0.009,0.026,1088.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-02",6,4.2,148.56,,0,0.001,92.98,0.0595,0.014,0.0218,1563.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-05",3,2.29,62.87,,0,0.001,42.938,0.059,0.006,0.0163,722.519,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-06",3,2.03,49.07,,0,0.001,34.282,0.059,0.007,0.0233,576.933,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-09",3,1.28,29.6,,0,0.001,20.84,0.0597,0.006,0.054,350.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-10",2,1.28,30.02,,0,0.001,20.968,0.0595,0.009,0.0375,353.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-11",2,1.28,29.07,,0,0.001,20.683,0.059,0.01,0.04,347.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-01",2,1.3,30.4,,0,0.001,21.32,0.059,0.009,0.037,358.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","El Cajon Energy Center",57001,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-06",11,9.32,390.8,,0.001,0.001,226.714,0.0591,0.014,0.0163,3816.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-07",9,6.75,283.67,,0.001,0.001,166.819,0.0594,0.012,0.0148,2806.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-08",14,11.89,381.1,,0.001,0.001,233.129,0.0594,0.014,0.008,3921.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-09",6,3.52,86.02,,0,0.001,56.135,0.0593,0.005,0.017,945.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-10",3,1.64,32.64,,0,0.001,22.532,0.059,0.002,0.0093,379.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-13",3,1.7,33.47,,0,0.001,23.332,0.0593,0.002,0.014,392.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-14",2,1.72,33.5,,0,0.001,23.556,0.06,0.002,0.0115,395.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-17",3,1.59,30.88,,0,0.001,21.632,0.0593,0.002,0.0173,364.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-24",4,2.7,57.4,,0,0.001,38.948,0.059,0.005,0.0253,655.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-25",3,1.77,34.64,,0,0.001,24.446,0.0593,0.002,0.0317,411.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-27",3,1.64,32.16,,0,0.001,22.632,0.059,0.003,0.0097,381.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-28",3,1.95,57.3,,0,0.001,35.82,0.059,0.004,0.013,603.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-29",3,1.7,33.94,,0,0.001,23.544,0.059,0.004,0.026,396.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-30",4,2.46,54.25,,0,0.001,36.137,0.059,0.004,0.0278,609.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-01",3,1.7,33.4,,0,0.001,23.39,0.059,0.003,0.018,393.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-02",3,1.68,43.72,,0,0.001,28.148,0.059,0.004,0.021,474.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-03",4,2.22,99.56,,0,0.001,57.618,0.0593,0.007,0.0428,969.768,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-04",6,5.62,170.6,,0.001,0.001,106.343,0.059,0.01,0.0117,1791.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-05",3,1.77,71.7,,0,0.001,41.404,0.0597,0.005,0.02,695.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-06",3,1.95,79.85,,0,0.001,47.555,0.059,0.005,0.0337,799.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-08",3,1.96,39.68,,0,0.001,27.536,0.0593,0.003,0.0133,463.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-13",3,1.68,33.58,,0,0.001,23.039,0.059,0.003,0.0197,388.329,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-14",3,1.7,33.88,,0,0.001,23.716,0.059,0.003,0.034,399.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-17",3,1.6,31.6,,0,0.001,22.11,0.0597,0.002,0.0203,371.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-21",3,1.72,34.22,,0,0.001,23.895,0.0593,0.002,0.0147,402.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-24",10,7.19,187.08,,0.001,0.0009,121.394,0.0594,0.011,0.0166,2040.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-25",6,3.83,123.34,,0,0.001,75.985,0.0592,0.007,0.0168,1278.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-26",6,3.25,91.96,,0,0.001,58.243,0.0592,0.006,0.0238,980.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-27",10,6.95,269.43,,0.001,0.001,160.749,0.059,0.011,0.0203,2705.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-28",10,8.74,363.19,,0.001,0.001,211.491,0.0592,0.013,0.0093,3560.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-02-29",3,1.65,32.65,,0,0.001,22.565,0.059,0.003,0.034,380.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-01",4,2.85,59.05,,0,0.001,40.19,0.059,0.004,0.018,676.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-02",3,2.09,42.14,,0,0.001,29.235,0.0597,0.003,0.0147,491.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-03",4,2.7,104.47,,0,0.001,62.152,0.0593,0.004,0.012,1045.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-04",4,2.58,111,,0,0.001,64.99,0.0593,0.005,0.011,1094.642,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-05",4,2.18,92.2,,0,0.001,54.115,0.0593,0.004,0.0185,911.413,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-08",3,1.7,33.52,,0,0.001,23.5,0.0593,0.003,0.0343,396.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-09",4,2.27,97.81,,0,0.001,57.827,0.059,0.006,0.0335,973.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-10",3,1.62,31.55,,0,0.001,22.353,0.0597,0.002,0.0187,375.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-12",10,8.68,247,,0.001,0.001,155.303,0.0594,0.013,0.0095,2611.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-13",8,5.92,164.29,,0.001,0.001,104.201,0.0593,0.009,0.0134,1753.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-14",5,3.97,125.48,,0,0.001,77.593,0.0592,0.007,0.0128,1305.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-15",3,2.24,50,,0,0.001,33.836,0.059,0.003,0.0147,569.751,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-16",7,4.17,140.13,,0,0.001,86.016,0.0597,0.008,0.0229,1446.869,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-21",3,1.62,31.98,,0,0.001,22.4,0.0597,0.003,0.0193,376.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-22",3,1.67,35.83,,0,0.001,24.199,0.0597,0.003,0.0183,406.613,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-28",3,1.97,39.8,,0,0.001,27.366,0.0593,0.004,0.0213,460.753,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-05",6,3.38,65.66,,0,0.001,45.762,0.0593,0.006,0.0243,770.289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-06",7,3.93,133.08,,0,0.001,80.62,0.0591,0.009,0.0334,1357.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-07",3,1.68,38.7,,0,0.001,25.336,0.0593,0.003,0.017,427.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-09",5,3.64,116.1,,0,0.001,71.639,0.0596,0.008,0.016,1204.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-14",4,2.47,108.07,,0,0.001,63.387,0.059,0.005,0.0273,1067.458,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-16",3,1.7,33.8,,0,0.001,23.41,0.0593,0.003,0.02,393.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-21",4,2.52,86.29,,0,0.001,52.702,0.0593,0.005,0.0125,886.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-22",1,0.85,27.2,,0,0.001,16.83,0.059,0.001,0.008,283.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-24",9,7.73,349.14,,0.001,0.001,201.183,0.059,0.013,0.0104,3386.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-25",3,2.02,40.78,,0,0.001,28.228,0.059,0.003,0.0167,475.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-26",5,3.2,146,,0,0.001,85,0.0594,0.006,0.0274,1430.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-27",4,2.18,95.24,,0,0.001,56.046,0.0593,0.004,0.0335,943.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-28",4,2.2,96.8,,0,0.001,56.26,0.0593,0.005,0.0285,947.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-29",4,2.17,95.21,,0,0.001,55.679,0.0593,0.005,0.0348,937.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-04-30",6,4.28,170.5,,0.001,0.001,100.466,0.0592,0.007,0.0185,1690.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-01",11,8.92,264.32,,0.001,0.001,165.448,0.0595,0.012,0.0132,2784.556,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-03",3,1.72,64.64,,0,0.001,39.068,0.0593,0.005,0.026,657.409,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-06",1,0.02,0,,0,0,0.016,0.06,0,0.001,0.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-07",8,6.21,280.21,,0.001,0.001,163.154,0.0591,0.01,0.0146,2744.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-08",4,2.24,97.8,,0,0.001,57.628,0.0595,0.005,0.0198,968.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-09",4,3,79.2,,0,0.001,50.84,0.0595,0.004,0.0143,855.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-11",3,2.48,83.2,,0,0.001,50.616,0.059,0.005,0.0133,851.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-12",3,1.87,55.81,,0,0.001,35.059,0.059,0.004,0.0247,590.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-14",3,2.2,45.92,,0,0.001,31.372,0.0597,0.003,0.015,527.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-15",3,1.9,46.2,,0,0.001,30.06,0.0593,0.003,0.0187,505.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-16",4,3.3,77.5,,0,0.001,50.93,0.059,0.005,0.011,857.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-21",4,3.2,74.88,,0,0.001,49.308,0.059,0.005,0.0115,829.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-25",4,2.39,104.32,,0,0.001,60.678,0.0595,0.005,0.0195,1020.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-26",7,5.63,254.29,,0.001,0.001,148.435,0.0591,0.009,0.0147,2498.327,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-27",5,3.39,122.95,,0,0.001,75.26,0.0596,0.005,0.016,1265.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-28",5,3.2,133.05,,0,0.001,78.705,0.0594,0.005,0.0212,1323.365,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-29",4,2.22,78.66,,0,0.001,47.998,0.0598,0.004,0.0273,806.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-30",5,4.22,105.02,,0,0.001,68.534,0.0592,0.005,0.0096,1153.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-05-31",3,1.72,35.4,,0,0.001,24.634,0.06,0.003,0.0203,413.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-01",4,2.28,77.9,,0,0.001,47.42,0.0598,0.004,0.0153,796.731,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-02",5,3.35,143.95,,0,0.001,83.774,0.0594,0.006,0.006,1409.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-03",7,5.36,215.2,,0.001,0.001,126.362,0.0591,0.008,0.0106,2127.783,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-04",5,3.37,145.6,,0,0.001,84.462,0.0596,0.006,0.0068,1420.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-08",3,2.4,104.8,,0,0.001,60.28,0.059,0.005,0.01,1015.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-09",6,4.43,202.88,,0.001,0.001,115.618,0.059,0.008,0.013,1945.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-10",10,7.39,299.25,,0.001,0.0009,177.451,0.0533,0.011,0.0077,2986.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-11",4,3.08,140,,0,0.001,81.392,0.0593,0.006,0.0093,1369.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-22",5,3.2,135.35,,0,0.0008,79.865,0.0594,0.005,0.0218,1343.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-23",3,1.9,82.44,,0,0.001,48.43,0.0593,0.005,0.0173,815.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-24",4,2.2,94,,0,0.001,55.22,0.0593,0.004,0.026,928.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-26",6,4.78,167.7,,0.001,0.001,102.21,0.0597,0.007,0.0147,1718.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-27",5,3.25,115.05,,0,0.001,68.775,0.0592,0.005,0.0188,1157.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-28",3,1.97,49.05,,0,0.001,31.827,0.059,0.003,0.0143,535.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-01",3,1.7,48.5,,0,0.001,31.01,0.0597,0.003,0.029,521.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-03",4,2.53,103.14,,0,0.001,61.07,0.0595,0.004,0.0165,1027.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-04",3,2.31,97.94,,0,0.001,58.148,0.0593,0.004,0.0127,978.519,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-05",4,3.25,148.55,,0,0.001,86.295,0.059,0.007,0.0108,1452.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-06",5,3.28,148.16,,0,0.001,86.604,0.059,0.006,0.0216,1457.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-07",4,2.25,98.84,,0,0.001,57.777,0.0598,0.004,0.023,971.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-08",4,2.18,96.32,,0,0.001,56.12,0.0593,0.005,0.0325,945.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-09",5,3.2,143.6,,0,0.001,84.06,0.0596,0.007,0.0262,1414.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-10",7,5.68,267.4,,0.001,0.001,154.792,0.0591,0.01,0.0121,2605.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-11",8,7.21,301.36,,0.001,0.001,176.283,0.0595,0.01,0.0083,2965.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-12",8,6.17,286.05,,0.001,0.001,163.65,0.0594,0.011,0.0075,2752.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-13",7,6.12,288.24,,0.001,0.001,166.02,0.0593,0.012,0.0097,2793.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-14",5,3.25,146.79,,0,0.001,84.824,0.0592,0.006,0.0214,1427.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-15",3,2.08,91.2,,0,0.001,52.874,0.059,0.007,0.013,890.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-16",4,2.22,93.17,,0,0.001,55.133,0.0598,0.004,0.018,926.858,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-17",5,3.14,142.24,,0,0.001,82.17,0.059,0.008,0.01,1382.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-18",3,2.45,98.32,,0,0.001,58.211,0.0593,0.005,0.011,979.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-19",4,2.17,96.24,,0,0.001,56.134,0.0595,0.005,0.0315,944.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-20",5,3.12,141.1,,0,0.0008,81.732,0.0592,0.007,0.0096,1374.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-21",8,7.1,342.7,,0.001,0.001,203.29,0.0591,0.016,0.0168,3419.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-22",10,9.12,336.24,,0.001,0.001,203.656,0.0592,0.015,0.0115,3424.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-24",3,1.6,47.28,,0,0.001,30.3,0.059,0.004,0.015,510.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-25",4,2.72,117.72,,0,0.001,70.524,0.0593,0.006,0.015,1186.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-26",5,3.72,142.77,,0,0.001,86.785,0.0592,0.007,0.013,1459.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-27",5,3.57,145.86,,0,0.001,88.055,0.0594,0.008,0.0188,1482.679,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-28",5,3.2,140.7,,0,0.001,83.75,0.0592,0.007,0.0278,1410.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-29",6,4.2,192.3,,0.001,0.001,113.68,0.0592,0.008,0.0207,1913.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-30",9,7.2,336.3,,0.001,0.001,199.18,0.0593,0.014,0.0153,3352.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-07-31",9,7.43,290.32,,0.001,0.001,177.227,0.0594,0.013,0.0169,2980.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-01",5,3.2,144.3,,0,0.001,86.36,0.0594,0.007,0.0266,1452.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-02",5,3.22,144.3,,0,0.001,85.826,0.0592,0.007,0.025,1443.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-03",5,3.2,143.9,,0,0.001,85.7,0.0592,0.007,0.0296,1441.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-04",4,2.22,96.3,,0,0.001,57.754,0.0593,0.005,0.029,971.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-09",5,3.22,145.04,,0,0.001,86.462,0.0594,0.007,0.0308,1453.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-10",4,2.45,107.68,,0,0.001,64.669,0.0598,0.006,0.0295,1087.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-11",3,2.16,88.22,,0,0.001,53.168,0.0593,0.006,0.016,894.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-12",5,3.78,172.16,,0.001,0.001,101.75,0.0596,0.008,0.0122,1712.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-13",9,7.94,333.44,,0.001,0.001,200.55,0.0594,0.014,0.0096,3372.333,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-14",10,8.93,400.53,,0.001,0.001,238.045,0.0593,0.017,0.0123,4002.698,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-15",10,8.2,383.8,,0.001,0.001,227.156,0.0596,0.015,0.0159,3818.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-16",9,7.3,340.3,,0.001,0.001,201.11,0.0592,0.014,0.0127,3384.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-17",2,0.94,40.8,,0,0.001,24.184,0.0595,0.003,0.039,407.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-18",12,9.29,428.9,,0.001,0.001,254.342,0.0594,0.02,0.0383,4280.299,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-19",12,10.5,431.18,,0.001,0.001,260.451,0.0595,0.018,0.0112,4380.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-20",8,6.21,287.21,,0.001,0.001,171.16,0.0593,0.013,0.0246,2881.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-21",7,5.18,238.74,,0.001,0.001,141.688,0.0591,0.01,0.0229,2384.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-22",5,3.45,145.87,,0,0.001,87.118,0.059,0.007,0.0238,1466.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-23",5,3.42,144.15,,0,0.001,85.347,0.0592,0.007,0.026,1435.932,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-24",9,7.68,325.6,,0.001,0.001,194.668,0.0592,0.013,0.0097,3274.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-25",8,6.2,292.3,,0.001,0.001,172.71,0.0595,0.013,0.0204,2904.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-26",8,6.2,288.2,,0.001,0.001,171.83,0.0593,0.013,0.0285,2891.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-27",9,7.93,338.79,,0.001,0.001,203.567,0.059,0.014,0.0124,3425.009,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-28",6,4.22,193.18,,0.001,0.001,115.294,0.0593,0.009,0.033,1940.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-29",3,2.12,91.24,,0,0.001,54.932,0.0593,0.005,0.0133,924.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-03",5,3.2,144.04,,0,0.001,86.352,0.0596,0.007,0.0288,1451.808,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-04",8,6.45,299.25,,0.001,0.001,179.465,0.0593,0.013,0.0156,3019.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-05",9,8.02,363.2,,0.001,0.001,217.63,0.0593,0.015,0.0089,3661.354,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-06",10,8.75,409.35,,0.001,0.001,244.71,0.0591,0.018,0.0101,4118.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-07",7,5.22,241.18,,0.001,0.001,142.212,0.0591,0.011,0.0217,2393.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-08",6,4.18,192.66,,0.001,0.001,113.394,0.059,0.007,0.0215,1908.552,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-09",4,2.22,96.82,,0,0.001,57.664,0.0595,0.006,0.0453,970.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-10",4,2.2,95.8,,0,0.001,56.85,0.059,0.005,0.0288,957.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-11",4,2.22,97.75,,0,0.001,57.836,0.0593,0.005,0.0253,973.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-12",4,2.97,134.44,,0,0.001,79.431,0.059,0.007,0.011,1335.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-13",3,1.95,39.25,,0,0.001,27.53,0.0593,0.003,0.0123,463.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-14",5,4.2,189.9,,0.001,0.001,111.965,0.0592,0.01,0.0112,1885.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-15",6,4.97,195.79,,0.001,0.001,119.107,0.0592,0.01,0.0112,2005.821,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-16",7,4.81,212.62,,0.001,0.001,126.614,0.0591,0.01,0.0136,2131.986,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-17",7,5.7,267.7,,0.001,0.001,157.18,0.0591,0.012,0.014,2644.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-18",11,9.45,418.03,,0.001,0.001,246.496,0.0593,0.017,0.0146,4147.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-19",4,3.2,136,,0,0.001,81.4,0.0593,0.008,0.0155,1369.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-20",4,2.7,110.3,,0,0.001,66.295,0.0593,0.005,0.0158,1115.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-21",6,4.19,163.53,,0.001,0.001,99.165,0.0593,0.008,0.0103,1667.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-22",4,2.63,116.78,,0,0.001,68.925,0.059,0.006,0.0165,1160.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-23",5,3.23,147.4,,0,0.0008,87.747,0.0592,0.009,0.0132,1476.423,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-24",4,2.12,91.1,,0,0.001,54.358,0.059,0.005,0.0103,913.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-27",4,2.21,95.4,,0,0.001,56.825,0.0593,0.005,0.0305,956.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-28",7,5.6,226.88,,0.001,0.001,136.364,0.0591,0.01,0.0123,2293.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-29",6,4.47,205.28,,0.001,0.001,121.979,0.0595,0.01,0.0175,2052.109,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-09-30",8,6.94,306.64,,0.001,0.001,181.676,0.0593,0.014,0.012,3058.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-01",7,5.67,249.37,,0.001,0.001,147.485,0.0591,0.012,0.0151,2481.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-02",6,5.1,235.1,,0.001,0.001,137.98,0.0592,0.01,0.0108,2320.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-03",6,4.47,169.91,,0.001,0.001,103.273,0.0595,0.009,0.0208,1737.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-04",6,4.95,210.4,,0.001,0.001,126.235,0.0593,0.01,0.012,2123.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-05",11,9.49,444.55,,0.001,0.001,262.192,0.0592,0.018,0.0112,4412.583,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-06",6,4.22,162.26,,0.001,0.001,99.46,0.0593,0.008,0.0255,1672.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-07",4,2.24,95.32,,0,0.001,57.596,0.0593,0.005,0.0305,969.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-10",3,2.05,47.55,,0,0.001,31.47,0.0597,0.003,0.0247,528.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-12",8,6.67,314.76,,0.001,0.001,183.562,0.0595,0.015,0.014,3087.457,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-13",8,6.72,257.38,,0.001,0.001,157.288,0.0593,0.011,0.0175,2646.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-14",7,5.45,225.06,,0.001,0.001,136.184,0.0594,0.01,0.0161,2290.293,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-15",7,5.43,253.76,,0.001,0.001,150.223,0.0594,0.012,0.0194,2525.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-16",7,5.15,235.12,,0.001,0.001,141.162,0.0593,0.011,0.0194,2374.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-17",4,3.1,138.1,,0,0.001,82.09,0.0593,0.007,0.0115,1379.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-18",4,2.6,114.35,,0,0.001,67.805,0.059,0.006,0.0195,1141.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-19",4,2.19,95.45,,0,0.001,56.789,0.0595,0.004,0.0275,955.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-20",5,3.14,139.12,,0,0.001,83.668,0.0594,0.007,0.01,1407.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-21",4,2.67,107.21,,0,0.001,65.602,0.0595,0.006,0.0325,1102.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-23",3,1.6,32.1,,0,0.001,22.84,0.0593,0.003,0.018,384.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-25",3,1.69,33.68,,0,0.001,23.796,0.06,0.003,0.0213,399.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-26",3,1.6,31.5,,0,0.001,22.65,0.059,0.004,0.0277,381.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-27",3,1.72,37.72,,0,0.001,26.164,0.0597,0.004,0.0273,439.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-01",3,1.72,33.85,,0,0.001,24.219,0.0593,0.003,0.0193,408.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-02",4,2.5,111.59,,0,0.001,66.329,0.0593,0.006,0.016,1116.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-03",2,1.7,38.25,,0,0.001,25.84,0.059,0.003,0.014,435.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-04",4,2.72,58.22,,0,0.001,40.622,0.0593,0.005,0.0208,684.663,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-05",6,4.67,142.82,,0,0.001,91.025,0.0595,0.007,0.012,1530.857,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-06",4,2.85,60.1,,0,0.001,41.605,0.0595,0.005,0.0168,699.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-08",3,1.92,36.73,,0,0.001,26.316,0.059,0.004,0.0177,443.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-09",6,3.42,68.14,,0,0.001,48.19,0.0595,0.007,0.0443,810.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-10",3,1.68,36.55,,0,0.001,24.753,0.059,0.004,0.025,417.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-11",3,2.18,41.8,,0,0.001,30.042,0.0597,0.005,0.0247,505.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-14",3,1.88,37.95,,0,0.001,27.146,0.06,0.003,0.0143,455.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-15",4,2.87,59.15,,0,0.001,41.829,0.0598,0.004,0.0108,702.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-16",3,1.66,32.89,,0,0.001,23.449,0.059,0.003,0.0223,395.446,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-17",1,0.1,0,,0,0.001,0.54,0.06,0.001,0.142,9.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-20",3,1.67,33.36,,0,0.001,23.561,0.059,0.002,0.0127,396.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-21",3,2.22,46.7,,0,0.001,32.339,0.0593,0.004,0.0197,544.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-22",4,2.45,52.4,,0,0.001,36.685,0.0593,0.004,0.0188,616.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-24",3,1.7,33.72,,0,0.001,24.142,0.0597,0.002,0.0373,405.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-29",3,1.7,33.8,,0,0.001,24.18,0.0597,0.002,0.0127,406.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-11-30",3,2.13,49.86,,0,0.001,33.952,0.0597,0.003,0.013,571.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-01",4,2.37,56.48,,0,0.001,38.471,0.0593,0.004,0.0195,647.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-02",2,1.62,32.16,,0,0.001,23.008,0.0595,0.004,0.016,387.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-03",3,1.92,38.56,,0,0.001,27.53,0.0593,0.003,0.0227,463.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-04",3,1.65,32.4,,0,0.001,23.39,0.059,0.003,0.028,394.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-05",3,1.65,32.68,,0,0.001,23.178,0.0597,0.003,0.0233,389.402,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-06",3,1.75,34.72,,0,0.001,24.541,0.0597,0.004,0.0197,412.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-10",3,1.67,37.6,,0,0.001,25.203,0.06,0.003,0.017,423.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-11",3,2.15,52.3,,0,0.001,34.705,0.0597,0.004,0.018,582.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-12",3,2.45,89.65,,0,0.001,54.468,0.0597,0.007,0.0173,915.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-14",7,5.93,133.48,,0,0.001,90.204,0.0593,0.009,0.0141,1517.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-15",3,2.18,47.72,,0,0.001,32.303,0.0593,0.006,0.028,543.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-16",7,5.88,158.76,,0.001,0.001,103.111,0.0593,0.01,0.018,1735.905,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-19",4,2.28,56.88,,0,0.001,37.9,0.0595,0.005,0.0453,637.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-23",2,1.72,36.12,,0,0.001,24.766,0.0595,0.004,0.0205,416.562,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-06",15,12.68,380.87,,0.001,0.001,237.731,0.0595,0.016,0.0087,3998.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-07",14,12.35,595.51,,0.002,0.001,340.146,0.0591,0.022,0.0089,5725.178,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-08",7,5.98,238.48,,0.001,0.001,140.244,0.0591,0.012,0.0103,2361.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-09",7,5.48,261.86,,0.001,0.001,148.966,0.0593,0.011,0.0183,2506.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-10",6,4.18,197.58,,0.001,0.001,111.998,0.0593,0.008,0.0252,1885.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-13",5,2.19,95.24,,0,0.0008,54.897,0.0474,0.003,0.01,924.577,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-17",3,1.59,30.88,,0,0.001,21.546,0.0593,0.002,0.0107,362.381,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-24",3,1.7,33.4,,0,0.001,23.302,0.059,0.002,0.0173,391.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-27",3,1.6,31.2,,0,0.001,21.38,0.0593,0.003,0.037,360.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-30",2,1.7,35.74,,0,0.001,24.069,0.0595,0.004,0.017,404.417,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-01",3,1.72,34.88,,0,0.001,24.008,0.0593,0.003,0.0327,404.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-04",2,0.1,0,,0,0.001,0.492,0.059,0.001,0.078,8.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-05",1,0.12,0,,0,0.001,0.6,0.059,0,0.029,10.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-06",3,1.97,80.78,,0,0.001,47.518,0.059,0.006,0.0277,800.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-14",3,1.71,33.87,,0,0.001,23.546,0.0597,0.003,0.0307,395.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-21",3,1.72,34.22,,0,0.001,23.588,0.059,0.003,0.0187,398.045,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-24",8,5.83,145.84,,0,0.001,94.001,0.0591,0.007,0.0188,1582.133,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-25",5,3.53,115.47,,0,0.001,70.729,0.0592,0.008,0.0156,1190.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-26",5,3.66,107.54,,0,0.001,66.986,0.0592,0.006,0.009,1127.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-27",8,4.94,185.83,,0.001,0.001,110.054,0.0591,0.01,0.0289,1852.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-28",10,8.47,376.96,,0.001,0.001,215.131,0.0593,0.014,0.0119,3620.617,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-01",4,2.85,59.05,,0,0.001,39.78,0.0595,0.003,0.0168,668.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-02",3,1.7,35.25,,0,0.001,23.925,0.0593,0.003,0.0197,402.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-03",3,1.69,35.05,,0,0.001,23.885,0.0597,0.003,0.0233,400.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-04",3,1.58,32.6,,0,0.001,22.26,0.0597,0.002,0.0153,374.398,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-05",3,1.68,34.56,,0,0.001,23.62,0.0593,0.002,0.016,397.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-12",8,5.82,176.41,,0.001,0.001,108.788,0.0591,0.009,0.0149,1832.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-13",6,4.35,129.27,,0,0.001,80.046,0.0592,0.009,0.0157,1348.147,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-14",5,3.72,125.51,,0,0.001,75.466,0.0592,0.006,0.0124,1269.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-21",2,1.7,34,,0,0.001,23.46,0.059,0.004,0.0185,395.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-22",3,1.7,33.9,,0,0.001,23.585,0.059,0.003,0.0193,397.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-28",3,1.68,32.88,,0,0.001,22.62,0.0597,0.002,0.02,380.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-05",5,3.33,70.2,,0,0.001,47.443,0.0592,0.005,0.016,799.095,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-06",7,3.93,133.15,,0,0.001,80.511,0.0593,0.008,0.0266,1354.877,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-07",3,1.68,35.6,,0,0.001,23.818,0.06,0.002,0.015,399.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-09",6,3.64,117.33,,0,0.001,71.152,0.0593,0.008,0.0177,1196.989,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-14",4,2.47,108.07,,0,0.001,62.352,0.059,0.005,0.0253,1049.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-15",1,0.13,0,,0,0.001,0.598,0.059,0,0.082,10.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-23",3,2.18,97.14,,0,0.001,56.052,0.0593,0.005,0.0107,942.951,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-24",8,6.13,242.38,,0.001,0.001,143.364,0.0593,0.01,0.0114,2412.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-25",3,1.75,34.93,,0,0.001,24.071,0.0593,0.002,0.015,405.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-28",4,2.2,99,,0,0.001,57.15,0.0595,0.005,0.0278,960.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-29",4,2.15,97.28,,0,0.001,55.916,0.0595,0.006,0.035,940.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-04-30",4,2.21,96.7,,0,0.0008,56.149,0.0593,0.005,0.0118,944.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-01",8,6.43,159.34,,0.001,0.001,102.98,0.0593,0.008,0.0115,1732.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-04",4,3,132.41,,0,0.001,76.104,0.059,0.005,0.0153,1280.729,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-05",4,3.46,74.2,,0,0.001,50.14,0.0593,0.004,0.01,843.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-09",4,3,103.4,,0,0.001,62.32,0.0593,0.004,0.0125,1048.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-11",3,2.25,72.2,,0,0.001,44.15,0.0593,0.004,0.011,742.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-14",3,1.67,33.04,,0,0.001,22.633,0.059,0.002,0.0147,381.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-15",3,1.9,46.2,,0,0.001,29.74,0.0593,0.003,0.0153,499.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-16",4,3.05,70.8,,0,0.001,45.855,0.0593,0.004,0.0103,771.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-21",4,2.97,73.76,,0,0.001,47.185,0.0598,0.003,0.0088,793.327,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-26",5,3.92,141.44,,0,0.001,85.168,0.059,0.005,0.0114,1433.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-27",7,5.19,246.64,,0.001,0.001,142.287,0.0593,0.009,0.021,2393.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-29",4,2.22,78.66,,0,0.001,47.498,0.0593,0.003,0.0238,798.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-30",3,1.23,22.33,,0,0.001,16.752,0.0593,0.002,0.0243,281.809,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-05-31",2,1.72,35.27,,0,0.001,24.098,0.059,0.003,0.0155,405.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-01",4,2.28,77.9,,0,0.001,46.394,0.059,0.003,0.011,781.253,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-02",4,3.08,140.1,,0,0.001,79.41,0.059,0.005,0.0078,1336.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-03",6,4.16,193.68,,0.001,0.001,108.917,0.059,0.006,0.0122,1835.277,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-04",5,3.37,145.6,,0,0.001,82.994,0.0594,0.005,0.0058,1396.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-08",3,2.4,104.8,,0,0.001,59.46,0.059,0.004,0.0083,1000.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-09",3,2.9,124.4,,0,0.001,70.3,0.0593,0.005,0.0083,1182.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-10",10,7.41,304.02,,0.001,0.0009,176.485,0.0537,0.011,0.0072,2966.781,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-11",4,3.07,140,,0,0.001,79.185,0.0593,0.006,0.009,1333.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-22",5,3.2,137.35,,0,0.001,79.155,0.0596,0.005,0.0182,1332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-23",3,1.58,68.78,,0,0.001,39.28,0.0593,0.004,0.019,660.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-24",3,1.82,80.06,,0,0.001,46.018,0.059,0.004,0.0173,773.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-26",4,2.2,97.9,,0,0.001,56.84,0.0593,0.004,0.0285,955.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-27",4,3.03,112.79,,0,0.001,66.397,0.0595,0.004,0.0088,1116.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-03",3,1.73,75.98,,0,0.001,43.843,0.059,0.004,0.0143,738.097,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-04",3,2.08,87.6,,0,0.001,50.916,0.059,0.004,0.0113,856.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-05",4,2.93,107.18,,0,0.001,63.428,0.0593,0.005,0.0103,1067.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-06",3,2.47,110.46,,0,0.001,63.567,0.0593,0.005,0.0117,1069.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-07",2,1.87,72.06,,0,0.001,42.301,0.059,0.004,0.0115,712.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-09",3,2.45,50.17,,0,0.001,34.154,0.0597,0.004,0.0147,573.607,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-10",4,3.43,134.69,,0,0.001,78.804,0.0595,0.007,0.0143,1324.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-11",8,6.96,242.28,,0.001,0.001,144.673,0.0596,0.008,0.0091,2431.361,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-12",4,2.37,103.74,,0,0.001,58.845,0.0593,0.004,0.0145,990.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-14",7,6,280.84,,0.001,0.001,158.924,0.059,0.011,0.0106,2674.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-15",3,1.8,35.96,,0,0.001,24.42,0.0593,0.002,0.0197,411.122,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-18",3,1.87,37.16,,0,0.001,25.735,0.0597,0.002,0.0193,432.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-23",7,6.4,316,,0.001,0.001,180.46,0.0594,0.013,0.0104,3036.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-24",12,9.24,344.12,,0.001,0.0009,203.628,0.0593,0.014,0.0097,3426.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-25",3,2.2,73.4,,0,0.001,45.38,0.0593,0.003,0.0107,763.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-26",4,2.93,102.4,,0,0.001,62.378,0.0593,0.004,0.012,1050.187,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-27",4,2.7,66.45,,0,0.001,43.897,0.0598,0.004,0.0138,737.921,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-28",3,1.7,35.23,,0,0.001,24.359,0.0593,0.003,0.017,409.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-29",3,1.99,66.24,,0,0.001,40.529,0.0597,0.004,0.015,682.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-30",4,3.45,132.3,,0,0.001,78.95,0.0593,0.006,0.0098,1327.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-07-31",7,4.88,137.12,,0,0.001,87.139,0.0593,0.007,0.0224,1467.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-01",5,3.22,150.42,,0,0.001,86.75,0.0592,0.007,0.0234,1461.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-02",5,3.22,149.42,,0,0.001,86.14,0.0594,0.006,0.0236,1449.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-03",5,3.2,147.9,,0,0.001,86.31,0.0594,0.006,0.0216,1450.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-04",4,2.22,99.3,,0,0.001,57.992,0.0595,0.005,0.0265,974.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-09",4,2.2,97.8,,0,0.001,57.47,0.0593,0.005,0.029,967.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-10",3,2.11,91.39,,0,0.001,53.389,0.059,0.007,0.0167,899.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-11",3,2.15,90.09,,0,0.001,53.119,0.059,0.004,0.0133,894.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-12",4,3.16,132.84,,0,0.001,77.876,0.059,0.005,0.009,1311.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-13",8,6.44,307.98,,0.001,0.001,176.969,0.0593,0.011,0.0168,2976.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-14",10,8.93,408.53,,0.001,0.001,238.572,0.0594,0.015,0.0101,4013.991,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-15",7,6.45,306.8,,0.001,0.001,177.535,0.0591,0.012,0.0083,2987.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-16",8,6.3,298.7,,0.001,0.001,173.52,0.0593,0.011,0.0123,2921.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-17",11,9.25,450.75,,0.001,0.001,258.65,0.0591,0.017,0.0148,4354.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-18",11,9.19,443.08,,0.001,0.001,255.324,0.0594,0.016,0.0145,4296.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-19",11,9.98,441.2,,0.001,0.001,258.452,0.0593,0.016,0.0086,4347.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-20",8,6.21,299.21,,0.001,0.001,172.952,0.0595,0.011,0.019,2909.488,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-21",7,5.2,247.8,,0.001,0.001,143.42,0.0591,0.009,0.0197,2411.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-22",5,3.21,149.13,,0,0.001,86.883,0.059,0.006,0.024,1462.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-23",5,3.42,159.31,,0,0.001,93.048,0.059,0.006,0.0228,1564.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-24",8,6.05,247.86,,0.001,0.001,146.603,0.0591,0.01,0.0135,2467.887,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-25",8,6.22,299.42,,0.001,0.001,173.29,0.0591,0.01,0.0171,2916.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-26",8,6.2,300.2,,0.001,0.001,173.14,0.0594,0.01,0.017,2913.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-27",9,7.67,340.04,,0.001,0.001,198.583,0.0591,0.012,0.0104,3344.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-28",6,4.22,198.08,,0.001,0.001,115.64,0.0593,0.007,0.0208,1944.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-29",3,2.12,93.24,,0,0.001,54.456,0.059,0.004,0.0127,915.932,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-03",3,1.72,35.94,,0,0.001,24.794,0.0593,0.003,0.019,417.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-04",6,4.93,182.96,,0.001,0.001,111.406,0.0593,0.008,0.0115,1875.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-05",8,6.93,289.71,,0.001,0.001,171.409,0.0591,0.011,0.008,2883.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-06",9,8.47,317.56,,0.001,0.001,191.813,0.0591,0.014,0.0091,3228.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-13",3,1.7,34,,0,0.001,23.32,0.0597,0.003,0.0157,391.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-14",4,3.45,131.8,,0,0.001,78.355,0.059,0.006,0.0088,1319.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-15",3,2.5,100.4,,0,0.001,59.64,0.0593,0.005,0.009,1003.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-16",5,3.32,143.3,,0,0.001,84.55,0.059,0.006,0.0106,1423.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-17",5,4.18,197.82,,0.001,0.001,113.928,0.059,0.009,0.0108,1918.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-18",8,7.33,355.16,,0.001,0.001,203.067,0.0593,0.014,0.0086,3416.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-19",4,3.22,139.82,,0,0.001,81.386,0.0595,0.006,0.0108,1368.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-20",3,2.18,63.8,,0,0.001,40.184,0.0593,0.003,0.0127,676.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-21",6,4.14,87.24,,0,0.001,59.448,0.0592,0.005,0.0088,1001.258,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-28",4,3.06,93.64,,0,0.001,58.563,0.0593,0.004,0.0168,985.503,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-29",3,1.67,36.53,,0,0.001,24.886,0.0593,0.002,0.014,418.343,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-09-30",6,4.92,116.4,,0,0.001,76.574,0.0593,0.006,0.0128,1289.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-01",6,5.15,239.11,,0.001,0.001,137.546,0.0592,0.01,0.0098,2313.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-02",6,4.35,203.6,,0.001,0.001,116.715,0.0592,0.008,0.013,1964.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-03",5,3.17,148.38,,0,0.001,85.004,0.0592,0.007,0.0292,1431.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-04",6,4.7,205.5,,0.001,0.001,120.9,0.0592,0.008,0.0117,2033.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-05",8,7.28,353.1,,0.001,0.001,203.667,0.0593,0.013,0.008,3424.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-06",8,6.2,299,,0.001,0.001,172.94,0.0591,0.011,0.0178,2909.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-07",4,2.22,97.24,,0,0.001,57.562,0.059,0.004,0.0243,968.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-12",7,5.7,268.28,,0.001,0.001,153.66,0.059,0.009,0.0094,2587.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-13",7,5.45,232.15,,0.001,0.001,136.79,0.0593,0.009,0.0197,2301.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-14",7,5.45,230.06,,0.001,0.001,136.151,0.0593,0.008,0.013,2291.236,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-15",7,5.43,258.84,,0.001,0.001,150.244,0.0591,0.01,0.0183,2529.441,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-16",7,5.17,244.12,,0.001,0.001,142.221,0.0596,0.009,0.016,2390.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-17",4,3.08,138.22,,0,0.001,79.986,0.0598,0.006,0.0115,1345.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-18",4,2.09,42,,0,0.001,29.24,0.0595,0.003,0.012,492.351,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-19",4,2.19,97.4,,0,0.001,56.883,0.0593,0.005,0.0338,958.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-20",5,3.12,139.1,,0,0.0008,80.336,0.059,0.006,0.011,1351.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-21",4,2.67,111.21,,0,0.001,65.882,0.059,0.005,0.027,1108.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-26",3,1.62,31.88,,0,0.001,22.298,0.0593,0.003,0.0217,375.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-01",5,3.23,149.71,,0,0.001,87.971,0.0592,0.007,0.0272,1481.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-02",5,3.18,147.32,,0,0.001,86.066,0.0592,0.006,0.0286,1449.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-04",4,2.18,95.74,,0,0.001,56.828,0.0595,0.005,0.032,955.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-05",7,5.68,236.85,,0.001,0.001,139.553,0.0594,0.01,0.0106,2346.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-06",4,2.58,55.22,,0,0.001,37.456,0.0593,0.003,0.014,629.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-09",3,1.7,34.97,,0,0.001,24.055,0.0593,0.003,0.023,404.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-10",3,1.7,37.95,,0,0.001,25.515,0.059,0.003,0.0193,430.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-14",2,1.03,18.95,,0,0.001,13.69,0.0595,0.003,0.018,230.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-15",3,1.86,37.2,,0,0.001,25.826,0.059,0.002,0.0107,435.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-16",4,2.2,97.7,,0,0.001,57.19,0.0593,0.004,0.0285,962.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-18",1,0.12,0,,0,0.001,0.612,0.059,0.001,0.161,10.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-21",3,1.68,35.32,,0,0.001,24.036,0.0593,0.003,0.019,405.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-22",4,2.45,54.4,,0,0.001,36.495,0.0593,0.003,0.0155,614.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-24",3,1.72,33.76,,0,0.001,23.694,0.0597,0.003,0.0417,397.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-29",3,1.7,33.8,,0,0.001,23.63,0.0593,0.002,0.0117,397.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-11-30",3,1.59,36.55,,0,0.001,24.756,0.059,0.002,0.0137,416.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-02",2,1.62,32.16,,0,0.001,22.584,0.0595,0.003,0.0155,380.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-03",3,1.93,39.08,,0,0.001,27.336,0.0597,0.003,0.0147,459.552,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-05",3,1.65,32.68,,0,0.001,22.861,0.059,0.003,0.0207,385.537,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-12",4,2.73,111.48,,0,0.001,66.029,0.0593,0.005,0.0305,1110.393,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-14",4,2.95,70.38,,0,0.001,46.247,0.0593,0.004,0.0158,777.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-15",3,1.66,34.59,,0,0.001,23.984,0.0593,0.003,0.0183,403.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-16",8,5.58,170.86,,0.001,0.001,105.612,0.0595,0.008,0.0171,1775.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-06",15,12.67,392.64,,0.001,0.001,252.105,0.0595,0.017,0.0085,4242.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-07",9,6.63,292.07,,0.001,0.001,172.51,0.0593,0.011,0.0094,2903.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-08",15,12.51,599.41,,0.002,0.0009,348.489,0.0592,0.024,0.0088,5862.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-09",10,7.03,294.56,,0.001,0.001,174.847,0.0591,0.013,0.017,2940.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-10",7,5.24,250.68,,0.001,0.001,145.56,0.0593,0.009,0.016,2448.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-11",3,1.87,58.58,,0,0.001,37.497,0.0593,0.004,0.0117,630.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-13",4,2.17,94.14,,0,0.001,55.44,0.0593,0.005,0.0233,933.671,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-17",3,1.59,30.88,,0,0.001,23.084,0.0593,0.002,0.0107,388.035,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-24",3,1.7,34.4,,0,0.001,24.956,0.059,0.002,0.012,419.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-25",3,1.73,34.62,,0,0.001,25.565,0.059,0.002,0.022,430.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-27",3,1.64,32.16,,0,0.0007,24.102,0.059,0.002,0.0077,405.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-28",4,2.18,72.78,,0,0.001,45.291,0.0598,0.003,0.0215,760.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-29",4,2.18,71,,0,0.001,45.124,0.0595,0.004,0.0268,758.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-30",3,1.7,37.1,,0,0.001,26.182,0.0593,0.003,0.0327,440.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-01",3,1.72,34.88,,0,0.001,25.38,0.059,0.003,0.0267,427.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-03",3,1.91,39.43,,0,0.001,28.394,0.059,0.005,0.018,477.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-04",5,4.49,121.61,,0,0.001,80.515,0.0592,0.009,0.0144,1355.393,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-05",3,2,68.8,,0,0.001,42.24,0.0597,0.004,0.015,710.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-13",2,1.58,29.27,,0,0.001,22.219,0.0595,0.006,0.0325,373.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-14",3,1.7,33.88,,0,0.001,25.17,0.0593,0.002,0.0213,424.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-21",3,1.74,34.58,,0,0.001,25.479,0.059,0.003,0.0167,429.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-24",9,6.48,177.89,,0.001,0.001,118.338,0.0592,0.009,0.0124,1990.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-25",6,3.67,136.84,,0,0.001,83.916,0.0595,0.008,0.0142,1411.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-26",6,3.34,99.71,,0,0.001,64.798,0.0593,0.005,0.014,1090.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-28",9,6.36,223.55,,0.001,0.001,139.144,0.0594,0.009,0.0169,2340.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-01",4,2.85,59.05,,0,0.001,42.58,0.0595,0.004,0.0168,715.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-02",3,1.55,32.15,,0,0.001,23.31,0.0597,0.003,0.022,391.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-03",4,2.45,100.91,,0,0.001,60.636,0.0593,0.005,0.0183,1021.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-04",4,2.26,100.86,,0,0.001,59.584,0.059,0.004,0.0193,1003.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-05",4,2.17,94.2,,0,0.0008,56.343,0.0595,0.004,0.0095,949.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-09",3,1.95,80.85,,0,0.001,48.8,0.059,0.006,0.0157,820.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-12",10,8.12,229.82,,0.001,0.001,150.34,0.0594,0.011,0.0094,2527.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-13",7,5.12,148.82,,0,0.001,97.092,0.0597,0.008,0.0106,1633.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-14",5,3.72,125.51,,0,0.001,79.247,0.0592,0.005,0.0098,1332.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-16",4,2.22,100.9,,0,0.001,59.204,0.059,0.005,0.0225,997.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-21",2,1.7,34,,0,0.001,25.16,0.0595,0.004,0.019,423.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-22",3,1.7,35.25,,0,0.001,25.455,0.06,0.003,0.019,427.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-28",3,1.72,34.45,,0,0.001,25.377,0.0597,0.004,0.0203,426.681,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-05",5,3.31,69.4,,0,0.001,49.599,0.0592,0.004,0.0126,834.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-06",6,3.57,125.55,,0,0.001,78.34,0.0595,0.006,0.0213,1317.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-07",3,1.68,33.02,,0,0.001,24.294,0.0597,0.003,0.015,407.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-09",5,3.59,117.08,,0,0.001,73.685,0.059,0.007,0.0118,1240.194,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-14",4,2.47,108.19,,0,0.001,64.264,0.059,0.004,0.0185,1081.869,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-21",3,1.67,55.43,,0,0.001,34.813,0.059,0.002,0.0087,586.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-24",10,7.58,358.75,,0.001,0.001,211.294,0.059,0.012,0.0123,3555.001,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-25",3,2.02,40.36,,0,0.001,29.88,0.059,0.003,0.017,502.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-26",4,2.72,119.88,,0,0.001,71.188,0.0593,0.004,0.0165,1198.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-27",4,2.16,97.24,,0,0.001,57.68,0.059,0.003,0.0225,972.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-28",3,1.86,82.32,,0,0.001,49.158,0.059,0.004,0.0117,828.178,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-29",4,2.15,97.28,,0,0.001,57.411,0.0593,0.005,0.028,966.429,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-04-30",4,2.2,96.88,,0,0.001,57.536,0.059,0.005,0.008,968.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-01",8,6.43,159.65,,0.001,0.001,108.946,0.0593,0.007,0.01,1832.253,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-04",4,3.01,132.14,,0,0.001,78.715,0.0595,0.005,0.0133,1323.071,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-05",8,5.59,176.47,,0.001,0.001,112.597,0.0593,0.008,0.0136,1893.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-06",6,3.74,158.38,,0,0.001,95.145,0.0593,0.007,0.017,1601.433,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-07",8,6.21,300.34,,0.001,0.001,175.34,0.0591,0.009,0.012,2951.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-08",4,2.22,98.84,,0,0.001,58.552,0.059,0.004,0.0175,986.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-09",4,2.98,103.42,,0,0.001,64.318,0.0593,0.004,0.0088,1081.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-11",3,2.48,83.88,,0,0.001,52.668,0.059,0.005,0.013,886.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-14",3,1.67,33.04,,0,0.001,24.274,0.059,0.002,0.016,409.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-15",3,1.9,46.2,,0,0.001,31.64,0.059,0.002,0.0127,532.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-16",3,2.01,43.26,,0,0.001,30.884,0.0593,0.002,0.0083,520.393,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-21",4,2.97,73.76,,0,0.001,50.103,0.0595,0.004,0.0103,843.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-25",3,2.18,94.34,,0,0.001,55.678,0.0597,0.005,0.009,935.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-26",5,3.65,161.8,,0,0.001,96.19,0.059,0.006,0.0176,1618.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-27",5,3.39,129.49,,0,0.001,79.514,0.0592,0.004,0.0104,1337.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-28",7,5.26,249.98,,0.001,0.001,147.006,0.0591,0.01,0.0173,2473.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-29",4,2.22,78.78,,0,0.001,49.184,0.059,0.004,0.0215,828.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-30",5,3.67,95.95,,0,0.001,64.44,0.059,0.005,0.0112,1085.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-05-31",2,1.7,35.7,,0,0.001,25.755,0.059,0.003,0.0115,433.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-02",3,1.55,30.69,,0,0.001,22.606,0.0597,0.003,0.0287,380.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-03",5,3.04,72.25,,0,0.001,49.926,0.059,0.005,0.0202,841.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-04",2,0.85,24.15,,0,0.001,15.87,0.06,0.002,0.009,266.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-09",5,3.4,141.55,,0,0.001,84.01,0.0594,0.007,0.0176,1412.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-10",10,7.39,289.19,,0.001,0.0009,175.541,0.0534,0.011,0.0074,2953.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-23",2,1.4,26.6,,0,0.001,20.16,0.0595,0.002,0.014,338.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-26",3,1.97,55.83,,0,0.001,36.701,0.059,0.003,0.0113,618.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-27",4,3.03,112.79,,0,0.001,69.457,0.059,0.004,0.007,1169.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-03",4,2.51,104.82,,0,0.001,63.187,0.0593,0.005,0.0153,1064.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-04",3,2.06,87.08,,0,0.001,52.66,0.0593,0.004,0.0147,885.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-05",4,2.98,138.15,,0,0.001,81.089,0.059,0.006,0.011,1364.437,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-06",5,3.28,152.16,,0,0.001,89.632,0.059,0.006,0.0182,1509.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-07",4,2.27,101.94,,0,0.001,60.534,0.0593,0.004,0.021,1018.454,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-08",3,1.83,80.12,,0,0.001,47.819,0.059,0.005,0.0147,805.381,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-09",5,3.2,148.7,,0,0.001,87.63,0.0592,0.007,0.0204,1475.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-10",7,5.42,257.2,,0.001,0.001,151.179,0.0591,0.011,0.0171,2541.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-11",8,7.21,301.94,,0.001,0.001,179.514,0.0593,0.01,0.008,3021.353,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-12",6,5.35,250.59,,0.001,0.001,146.75,0.0592,0.009,0.0078,2469.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-13",6,4.1,191,,0.001,0.001,111.734,0.0592,0.008,0.0078,1879.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-14",5,3.22,147.16,,0,0.001,86.578,0.0594,0.006,0.02,1456.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-15",7,5.84,270.08,,0.001,0.001,156.46,0.0593,0.011,0.0091,2633.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-16",4,2.17,98.24,,0,0.001,57.972,0.0595,0.005,0.026,974.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-17",4,2.14,93.12,,0,0.001,55.39,0.0598,0.005,0.0093,931.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-18",4,2.21,101.45,,0,0.001,59.571,0.059,0.004,0.0233,1003.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-19",4,2.17,98.31,,0,0.001,58.155,0.0595,0.005,0.0285,979.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-20",5,3.12,142.1,,0,0.001,83.17,0.0594,0.007,0.0086,1398.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-21",4,2.42,109.72,,0,0.001,64.868,0.0593,0.005,0.0205,1092.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-24",3,1.58,47.5,,0,0.001,30.72,0.059,0.003,0.0107,517.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-25",3,2.2,74,,0,0.001,46.54,0.0597,0.003,0.008,782.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-26",4,3.2,108,,0,0.001,68.23,0.0593,0.005,0.0088,1148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-27",5,3.27,143.61,,0,0.001,84.858,0.0594,0.005,0.0188,1426.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-28",5,3.2,143.7,,0,0.001,84.94,0.059,0.006,0.021,1429.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-29",6,4.2,196.3,,0.001,0.001,115.49,0.0593,0.007,0.017,1942.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-30",9,7.2,346.2,,0.001,0.001,202.53,0.0594,0.012,0.0137,3406.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-07-31",9,7.43,327.62,,0.001,0.001,194.632,0.0593,0.012,0.0137,3274.646,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-09",3,1.9,38.4,,0,0.001,28.162,0.059,0.002,0.0103,474.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-10",3,1.87,62.09,,0,0.001,39.553,0.0593,0.003,0.0097,664.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-12",4,3.16,109.12,,0,0.001,68.752,0.0593,0.004,0.0078,1156.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-13",7,6.14,204.5,,0.001,0.001,128.365,0.0591,0.006,0.0063,2160.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-14",10,8.95,291.1,,0.001,0.001,185.185,0.0594,0.009,0.0063,3115.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-15",5,4.45,207.8,,0.001,0.001,122.345,0.0594,0.008,0.008,2057.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-16",7,6.07,282.59,,0.001,0.001,167.224,0.0593,0.009,0.0097,2812.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-17",8,7.24,216.44,,0.001,0.001,141.262,0.0595,0.009,0.0083,2375.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-18",11,10.25,299.4,,0.001,0.001,196.405,0.0594,0.009,0.0075,3304.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-19",11,9.66,231.99,,0.001,0.001,161.024,0.0594,0.01,0.0078,2708.253,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-20",6,4.43,191.31,,0.001,0.001,114.17,0.059,0.007,0.0098,1922.286,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-23",3,1.85,37.4,,0,0.001,27.393,0.0597,0.002,0.0103,460.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-24",7,5.42,159.3,,0.001,0.001,104.396,0.0594,0.005,0.0066,1756.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-25",3,2.47,63.28,,0,0.001,42.588,0.06,0.003,0.009,714.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-26",3,1.7,40.42,,0,0.001,27.808,0.059,0.002,0.0233,468.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-27",8,5.78,196.07,,0.001,0.001,123.191,0.0594,0.007,0.0106,2070.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-28",4,2.7,113,,0,0.001,68.66,0.0595,0.005,0.0148,1154.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-03",5,3.2,148.04,,0,0.001,87.768,0.0594,0.006,0.0224,1478.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-04",8,6.45,309.6,,0.001,0.001,182.75,0.0591,0.011,0.0128,3074.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-05",9,8,365.78,,0.001,0.001,217.594,0.0591,0.012,0.0071,3660.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-06",10,8.75,426.55,,0.001,0.001,251.245,0.0593,0.015,0.0094,4227.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-07",7,5.22,247.18,,0.001,0.001,145.206,0.0591,0.01,0.0173,2444.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-08",6,4.2,198.7,,0.001,0.001,116.1,0.0592,0.005,0.016,1953.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-09",4,2.18,98.66,,0,0.001,58.264,0.0593,0.004,0.0233,980.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-10",3,1.85,77.26,,0,0.001,46.131,0.0593,0.004,0.0133,775.803,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-11",4,2.22,99.75,,0,0.001,58.241,0.0593,0.004,0.022,978.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-12",4,2.47,112.64,,0,0.001,66.056,0.0595,0.005,0.0218,1111.171,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-13",3,1.7,34,,0,0.001,24.79,0.0593,0.002,0.012,417.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-14",5,3.98,187.05,,0.001,0.001,109.412,0.0592,0.007,0.01,1843.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-15",6,4.37,157.35,,0,0.001,97.553,0.0592,0.006,0.0145,1642.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-16",7,4.6,202.92,,0.001,0.001,120.851,0.0593,0.008,0.0103,2033.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-17",7,5.72,274.32,,0.001,0.001,159.92,0.0593,0.009,0.0091,2689.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-18",10,9.2,414.27,,0.001,0.001,243.634,0.0592,0.014,0.007,4100.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-19",4,3.22,139.82,,0,0.001,83.076,0.0593,0.007,0.0113,1398.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-20",4,2.7,112.3,,0,0.001,67.42,0.059,0.004,0.011,1135.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-21",6,3.83,101.18,,0,0.001,68.214,0.059,0.005,0.0088,1147.629,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-22",4,2.4,107.69,,0,0.001,63.552,0.0595,0.004,0.015,1068.679,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-23",5,3.23,151.4,,0,0.001,89.001,0.0592,0.006,0.0166,1497.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-24",4,2.14,95.12,,0,0.001,56.572,0.0593,0.004,0.01,952.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-27",4,2.18,97.4,,0,0.001,58.082,0.059,0.004,0.027,976.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-28",7,5.58,227,,0.001,0.001,136.186,0.0593,0.008,0.0101,2291.472,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-29",6,4.47,209.75,,0.001,0.001,123.329,0.059,0.009,0.0162,2075.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-09-30",7,6.18,240.98,,0.001,0.001,146.692,0.0591,0.01,0.0089,2469.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-01",6,5.09,237.92,,0.001,0.001,138.811,0.0592,0.008,0.009,2336.771,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-02",7,5.12,240.1,,0.001,0.0009,140.34,0.0591,0.009,0.0087,2363.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-03",5,3.18,148.74,,0,0.001,87.196,0.059,0.006,0.0246,1467.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-04",6,4.7,207.5,,0.001,0.001,123.87,0.0593,0.008,0.0122,2083.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-05",9,7.72,367.94,,0.001,0.001,215.516,0.0591,0.012,0.0092,3627.927,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-06",6,4.22,165.26,,0.001,0.001,101.17,0.0593,0.007,0.0195,1702.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-07",8,6.22,299.94,,0.001,0.001,176.36,0.0591,0.011,0.0168,2967.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-10",3,2.05,44.81,,0,0.001,31.515,0.059,0.003,0.0113,531.537,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-12",7,5.37,254.37,,0.001,0.001,147.828,0.0591,0.009,0.01,2487.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-13",12,9.38,438.38,,0.001,0.001,261.984,0.0593,0.03,0.0417,4406.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-14",11,8.58,292.16,,0.001,0.001,184.207,0.0591,0.012,0.0095,3101.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-15",7,5.45,259.8,,0.001,0.001,154.185,0.0593,0.01,0.0146,2594.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-16",7,5.17,244.12,,0.001,0.001,145.316,0.059,0.009,0.016,2446.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-17",4,3.1,138.1,,0,0.001,82.64,0.0595,0.006,0.0103,1389.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-18",4,2.37,48.6,,0,0.001,36.189,0.0595,0.004,0.0085,607.726,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-19",4,2.17,97.45,,0,0.001,58.749,0.0593,0.004,0.024,988.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-20",4,3.12,139.12,,0,0.001,83.028,0.0593,0.006,0.011,1396.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-21",4,2.67,111.21,,0,0.001,68.186,0.059,0.004,0.0198,1147.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-26",3,1.62,31.88,,0,0.001,24.12,0.059,0.002,0.011,405.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-01",5,3.23,151.71,,0,0.001,90.683,0.0594,0.005,0.0194,1526.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-02",2,0.37,7.48,,0,0.001,5.628,0.059,0.016,0.223,94.632,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-03",5,2.8,56.86,,0,0.001,42.894,0.0594,0.005,0.011,720.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-04",4,2.18,96.74,,0,0.001,58.55,0.0593,0.004,0.0225,985.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-05",7,5.67,238.14,,0.001,0.001,144.366,0.0594,0.008,0.0083,2427.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-06",4,2.55,54.65,,0,0.001,39.845,0.0595,0.003,0.0103,669.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-09",3,1.7,33.86,,0,0.001,25.507,0.0597,0.003,0.0173,428.497,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-10",3,1.7,38.3,,0,0.001,27.555,0.0593,0.002,0.013,462.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-11",3,2.2,44.76,,0,0.001,33.13,0.059,0.003,0.012,558.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-14",3,1.9,38.35,,0,0.001,28.873,0.0597,0.002,0.01,485.236,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-15",3,1.85,37.3,,0,0.001,27.986,0.0593,0.002,0.0153,471.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-16",5,3.21,150.37,,0,0.001,89.573,0.059,0.005,0.0198,1506.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-19",1,0.12,0,,0,0.001,0.768,0.059,0.001,0.109,12.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-21",3,1.7,35.56,,0,0.001,25.85,0.059,0.002,0.009,435.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-22",4,2.68,59.87,,0,0.001,42.975,0.0595,0.003,0.0098,722.067,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-24",3,1.7,34.34,,0,0.001,25.588,0.059,0.002,0.025,430.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-29",3,1.7,33.8,,0,0.001,25.62,0.06,0.002,0.0123,430.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-11-30",3,1.6,36.79,,0,0.001,26.461,0.0593,0.002,0.0127,445.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-02",3,2.1,43.1,,0,0.001,32.22,0.0593,0.004,0.0127,541.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-03",3,1.6,35.36,,0,0.001,25.848,0.0593,0.003,0.014,434.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-04",3,1.7,36.9,,0,0.001,27.03,0.059,0.003,0.0153,455.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-05",3,1.65,32.68,,0,0.001,24.766,0.0597,0.002,0.013,415.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-11",3,2.15,53.45,,0,0.001,36.675,0.0597,0.003,0.0097,616.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-12",3,2.45,107.62,,0,0.001,64.423,0.059,0.005,0.0097,1084.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-15",3,1.67,34.35,,0,0.0007,25.332,0.0593,0.003,0.0337,426.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-16",8,5.54,170.72,,0.001,0.001,110.78,0.0591,0.007,0.0156,1864.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-06",16,13.47,422.48,,0.001,0.001,268.239,0.0594,0.018,0.0156,4512.461,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-07",13,9.76,449.2,,0.001,0.001,262.195,0.0593,0.019,0.0205,4411.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-08",15,12.06,443.5,,0.001,0.001,271.372,0.0594,0.02,0.0099,4565.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-09",17,14.62,646.33,,0.002,0.001,375.686,0.0593,0.027,0.0134,6323.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-10",10,7.09,327.92,,0.001,0.001,190.324,0.0592,0.014,0.0122,3203.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-11",5,3.25,122.69,,0,0.001,74.28,0.0594,0.007,0.0222,1248.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-13",4,2.17,96.21,,0,0.001,56.082,0.0595,0.006,0.0333,942.941,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-14",5,3.4,68.66,,0,0.001,49.557,0.0594,0.007,0.02,833.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-16",3,2.18,90.06,,0,0.001,52.938,0.059,0.007,0.014,890.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-17",3,1.57,31,,0,0.001,23.026,0.0593,0.004,0.0193,388.402,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-24",4,2.95,67.35,,0,0.001,47.247,0.0595,0.004,0.0123,795.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-25",3,1.68,34,,0,0.001,24.584,0.0593,0.003,0.0157,414.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-27",3,1.64,32.16,,0,0.001,24.098,0.0593,0.003,0.0107,405.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-28",5,3.4,109.08,,0,0.001,69.098,0.0592,0.006,0.0076,1163.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-29",4,2.18,69.7,,0,0.001,43.874,0.0593,0.006,0.0365,738.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-30",6,3.78,85.51,,0,0.001,59.648,0.059,0.01,0.0227,1004.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-01-31",4,2.18,72,,0,0.001,45.4,0.0595,0.005,0.0383,764.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-01",3,1.77,35.52,,0,0.001,26.23,0.0597,0.003,0.02,440.597,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-03",4,2.19,98.68,,0,0.001,57.672,0.059,0.007,0.0388,970.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-04",7,5.97,205.41,,0.001,0.001,126.365,0.0596,0.016,0.0164,2124.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-05",3,2,65.8,,0,0.001,40.44,0.059,0.004,0.019,681.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-06",4,2.97,131.78,,0,0.001,77.606,0.0593,0.008,0.0348,1305.959,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-08",3,1.96,40.06,,0,0.001,29.26,0.0593,0.004,0.0153,491.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-13",3,1.68,33.25,,0,0.001,24.451,0.0593,0.004,0.025,411.001,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-14",6,3.4,67.86,,0,0.001,50.158,0.0592,0.007,0.0283,844.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-17",3,1.6,31.6,,0,0.001,23.485,0.0593,0.003,0.027,394.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-21",3,1.72,34.22,,0,0.001,25.347,0.059,0.003,0.015,427.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-24",10,7.75,207.63,,0.001,0.001,137.51,0.0594,0.012,0.0119,2313.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-25",7,5.66,185.55,,0.001,0.001,117.096,0.0594,0.011,0.0163,1969.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-26",6,3.39,85.04,,0,0.001,58.237,0.0592,0.006,0.0232,980.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-27",7,4.68,182.47,,0.001,0.001,110.938,0.0593,0.009,0.023,1865.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-28",11,9.22,414.42,,0.001,0.001,240.953,0.0594,0.018,0.0155,4051.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-01",4,2.85,58.8,,0,0.001,42.605,0.0593,0.005,0.0243,716.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-02",3,2.09,42.14,,0,0.001,30.916,0.0597,0.004,0.018,519.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-03",5,3.4,121.72,,0,0.001,74.967,0.0592,0.005,0.0154,1262.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-04",4,2.58,111.5,,0,0.001,65.844,0.059,0.006,0.013,1108.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-05",4,2.73,109.95,,0,0.001,66.443,0.059,0.005,0.0153,1118.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-08",3,1.68,33.44,,0,0.001,24.958,0.0593,0.004,0.0407,420.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-09",7,3.95,133.28,,0,0.001,83.855,0.0594,0.008,0.0231,1411.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-10",7,4.34,129.03,,0,0.001,83.013,0.0594,0.009,0.0297,1395.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-11",3,1.97,54.55,,0,0.001,36.169,0.059,0.003,0.015,609.381,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-12",11,9.02,260.36,,0.001,0.001,169.081,0.0594,0.012,0.0111,2843.867,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-13",8,5.9,164.85,,0.001,0.001,109.005,0.0591,0.011,0.0163,1834.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-14",8,5.63,199.98,,0.001,0.001,123.374,0.0594,0.012,0.0231,2076.259,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-15",3,2.24,50,,0,0.001,35.604,0.0593,0.005,0.0197,598.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-16",7,4.17,142.5,,0,0.001,89.261,0.059,0.01,0.0284,1503.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-21",3,1.62,31.98,,0,0.001,23.856,0.0593,0.004,0.0197,401.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-22",3,1.67,33.4,,0,0.001,24.659,0.0593,0.003,0.0177,414.742,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-27",1,0.1,0,,0,0.001,0.64,0.06,0.001,0.157,10.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-28",3,1.98,39.42,,0,0.001,29.192,0.0593,0.002,0.009,491.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-05",8,5.9,128.94,,0,0.001,90.8,0.0593,0.007,0.0106,1528.419,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-06",3,1.68,33.14,,0,0.001,24.648,0.0597,0.004,0.0373,414.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-07",2,0.3,1.52,,0,0.001,2.419,0.06,0.002,0.0945,40.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-08",3,1.7,34.05,,0,0.001,24.927,0.0597,0.004,0.023,419.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-09",6,3.62,117.49,,0,0.001,74.028,0.059,0.01,0.0198,1246.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-14",3,1.72,35.63,,0,0.001,25.902,0.0593,0.003,0.021,436.549,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-16",3,1.7,33.8,,0,0.001,24.89,0.0597,0.003,0.0257,418.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-21",4,2.78,93.5,,0,0.001,58.411,0.0595,0.004,0.0075,982.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-22",1,0.85,27.2,,0,0.001,17.51,0.059,0.001,0.008,294.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-24",8,6.66,294.87,,0.001,0.001,174.168,0.0595,0.013,0.0126,2928.905,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-25",3,2.02,40.78,,0,0.001,29.82,0.059,0.004,0.0223,502.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-26",3,1.95,43.65,,0,0.001,31.15,0.0597,0.004,0.017,524.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-27",3,1.7,33.55,,0,0.001,24.74,0.0593,0.003,0.0203,416.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-29",3,1.68,49.23,,0,0.001,31.93,0.0593,0.005,0.0227,536.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-01",8,6.42,160.49,,0.001,0.001,108.29,0.0591,0.01,0.0148,1824.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-03",3,1.72,69.18,,0,0.001,41.41,0.059,0.008,0.023,696.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-04",5,3.48,156.29,,0,0.001,91.099,0.0594,0.007,0.017,1532.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-05",9,6.18,236.48,,0.001,0.001,143.595,0.0593,0.013,0.0186,2416.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-06",4,2.69,111.23,,0,0.001,66.328,0.059,0.005,0.028,1116.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-07",7,5.9,254.89,,0.001,0.001,150.154,0.0593,0.011,0.0087,2525.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-08",4,2.24,98.92,,0,0.001,58.044,0.059,0.005,0.029,975.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-09",4,2.98,103.78,,0,0.001,63.66,0.0593,0.005,0.0133,1071.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-11",4,2.73,89.88,,0,0.001,55.872,0.059,0.005,0.027,940.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-12",3,1.98,63.05,,0,0.001,39.606,0.059,0.004,0.0157,666.454,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-16",5,3.58,83.12,,0,0.001,56.872,0.0594,0.005,0.027,957.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-21",4,2.55,68.22,,0,0.001,45.115,0.0593,0.005,0.0355,758.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-22",4,2.27,81.21,,0,0.001,49.427,0.0593,0.007,0.039,831.633,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-25",4,2.38,106.14,,0,0.001,61.978,0.0598,0.006,0.0223,1042.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-26",5,4.58,200.82,,0.001,0.001,118.072,0.059,0.007,0.0068,1988.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-27",5,3.39,125.95,,0,0.001,76.736,0.0592,0.006,0.019,1291.543,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-28",5,3.2,135.05,,0,0.001,80.075,0.0596,0.007,0.0188,1346.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-29",6,4.3,204.56,,0.001,0.001,118.724,0.0595,0.01,0.0247,1998.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-30",5,4.22,123.48,,0,0.001,79.83,0.0596,0.007,0.0114,1341.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-05-31",3,1.72,36.02,,0,0.001,25.634,0.0593,0.005,0.0243,431.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-01",4,2.28,77.9,,0,0.001,48.041,0.059,0.004,0.0178,809.357,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-02",5,3.35,148.28,,0,0.001,86.059,0.0596,0.006,0.0056,1446.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-03",7,5.36,219.33,,0.001,0.001,128.685,0.059,0.008,0.0089,2165.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-04",5,3.37,146.6,,0,0.001,84.368,0.0594,0.006,0.0056,1418.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-08",3,2.4,105.2,,0,0.001,60.72,0.059,0.005,0.0093,1020.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-09",7,5.41,250.01,,0.001,0.001,142.21,0.0593,0.011,0.0153,2392.132,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-10",10,8.07,302.83,,0.001,0.0009,182.778,0.0532,0.011,0.0064,3075.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-11",7,5.42,204.6,,0.001,0.0009,122.39,0.0591,0.007,0.006,2059.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-17",4,2.22,98.18,,0,0.001,57.54,0.059,0.004,0.0183,968.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-18",4,2.2,100.1,,0,0.001,58.23,0.0595,0.004,0.0218,979.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-22",5,3.47,152.12,,0,0.0008,88.927,0.0594,0.006,0.0168,1496.531,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-23",3,1.92,84.32,,0,0.001,49.612,0.0593,0.006,0.0147,833.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-24",4,2.2,98,,0,0.001,57.11,0.0593,0.005,0.024,961.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-26",6,4.78,173.7,,0.001,0.001,105.57,0.0592,0.009,0.0152,1776.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-27",5,3.27,118.04,,0,0.001,71.463,0.0594,0.005,0.0244,1201.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-28",3,2.22,56,,0,0.001,36.884,0.059,0.004,0.014,621.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-01",3,1.95,68.46,,0,0.001,41.964,0.0593,0.007,0.019,705.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-02",3,2.2,84.55,,0,0.001,50.77,0.0593,0.005,0.0213,853.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-03",4,2.78,118.14,,0,0.001,69.757,0.0593,0.005,0.0173,1173.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-04",3,2.33,99.99,,0,0.001,59.029,0.0593,0.005,0.017,993.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-05",5,3.6,138.32,,0,0.001,82.514,0.0596,0.01,0.0354,1387.594,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-06",5,3.22,150.9,,0,0.001,87.008,0.0594,0.007,0.0256,1464.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-07",4,2.27,101.94,,0,0.001,59.228,0.0595,0.005,0.0308,996.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-08",2,0.53,22,,0,0.001,12.864,0.0595,0.003,0.055,216.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-09",5,3.2,149.7,,0,0.001,86.29,0.0592,0.008,0.0392,1453.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-10",7,5.93,285.56,,0.001,0.001,164.671,0.059,0.013,0.0103,2772.513,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-11",8,7.21,303.57,,0.001,0.001,176.935,0.059,0.01,0.0083,2977.117,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-12",9,7.17,340.2,,0.001,0.0009,195.533,0.0584,0.014,0.0077,3288.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-13",8,6,276.6,,0.001,0.0009,159.668,0.0593,0.016,0.0114,2686.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-14",5,3.25,147.79,,0,0.001,85.437,0.0592,0.008,0.0312,1437.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-15",5,3.17,137.17,,0,0.001,80.051,0.0592,0.007,0.023,1346.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-16",8,6.22,300.3,,0.001,0.001,171.964,0.0591,0.014,0.0203,2893.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-17",4,3.12,142.24,,0,0.001,82.316,0.0593,0.007,0.0115,1386.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-18",4,2.23,101.55,,0,0.001,58.707,0.0593,0.005,0.0315,988.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-19",4,2.15,97.52,,0,0.0008,56.724,0.0595,0.006,0.0123,954.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-20",5,3.12,142.1,,0,0.0008,82.042,0.0594,0.008,0.01,1379.556,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-21",4,2.42,109.62,,0,0.001,63.734,0.0593,0.006,0.0305,1072.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-24",3,1.58,47.5,,0,0.001,30.262,0.0593,0.004,0.0163,509.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-25",4,2.7,121.3,,0,0.001,70.52,0.0593,0.006,0.014,1186.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-26",5,3.72,145.14,,0,0.001,87.001,0.0592,0.007,0.0156,1463.757,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-27",5,3.96,165.69,,0,0.001,96.946,0.0596,0.008,0.0138,1631.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-28",5,3.2,144.7,,0,0.001,83.7,0.0596,0.007,0.0264,1406.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-29",6,4.2,196.3,,0.001,0.001,113.45,0.059,0.008,0.0213,1910.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-30",9,7.22,349.3,,0.001,0.001,198.816,0.0594,0.014,0.0171,3345.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-07-31",10,8.18,373.34,,0.001,0.001,215.128,0.0593,0.015,0.0187,3619.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-01",5,3.2,150.4,,0,0.001,86.26,0.0592,0.007,0.0266,1451.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-02",5,3.22,150.42,,0,0.001,85.822,0.0594,0.007,0.0258,1443.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-03",5,3.2,147.9,,0,0.001,85.68,0.0594,0.007,0.0246,1440.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-04",4,2.2,100.4,,0,0.001,57.87,0.0593,0.005,0.0323,973.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-08",4,2.45,111.75,,0,0.001,64.93,0.0595,0.006,0.0295,1092.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-09",5,3.22,149.04,,0,0.001,86.208,0.0592,0.007,0.0288,1452.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-10",4,2.45,112.06,,0,0.001,64.715,0.059,0.005,0.03,1089.069,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-11",3,2.15,90.09,,0,0.001,53.004,0.059,0.006,0.0133,892.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-12",5,3.86,178.38,,0.001,0.001,102.51,0.0594,0.009,0.0128,1723.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-13",10,8.96,391.04,,0.001,0.001,226.086,0.0592,0.015,0.0094,3804.743,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-14",11,9.47,460.31,,0.001,0.001,262.54,0.0591,0.019,0.0175,4418.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-15",10,8.2,394.8,,0.001,0.001,226.412,0.0593,0.017,0.0173,3807.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-16",9,7.3,354.5,,0.001,0.001,201.01,0.0591,0.015,0.0136,3381.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-18",10,9.41,453.23,,0.001,0.001,259.088,0.0591,0.02,0.0095,4361.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-19",13,11.29,492.32,,0.001,0.001,287.763,0.0591,0.021,0.0147,4843.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-20",9,7.25,349.22,,0.001,0.001,201.079,0.0593,0.015,0.0183,3382.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-21",8,6.2,298.9,,0.001,0.001,172.08,0.0591,0.013,0.0195,2897.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-22",5,4.36,200.38,,0.001,0.001,115.862,0.0596,0.009,0.0098,1948.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-23",7,5.18,247.5,,0.001,0.001,142.28,0.0594,0.011,0.0203,2392.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-24",9,7.7,371.2,,0.001,0.001,212.86,0.0592,0.014,0.0092,3580.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-25",10,8.22,400.68,,0.001,0.001,230.274,0.0593,0.017,0.0175,3875.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-26",8,6.7,310.7,,0.001,0.001,179.75,0.0594,0.015,0.0139,3024.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-27",9,8.2,374.35,,0.001,0.001,216.605,0.059,0.016,0.0089,3646.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-28",7,5.72,262.02,,0.001,0.001,152.016,0.0591,0.013,0.016,2556.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-29",3,2.12,93.24,,0,0.001,54.588,0.059,0.005,0.0123,919.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-08-31",4,2.2,75,,0,0.001,46.02,0.0593,0.005,0.0358,775.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-03",5,3.22,148.06,,0,0.001,86.402,0.0592,0.007,0.0294,1453.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-04",8,6.68,322.3,,0.001,0.001,185.962,0.0593,0.015,0.013,3128.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-05",10,8.75,411.55,,0.001,0.001,238.437,0.0592,0.017,0.0155,4011.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-06",11,9.75,475.5,,0.001,0.001,273.34,0.0592,0.021,0.0109,4601.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-07",7,5.2,246.1,,0.001,0.001,140.87,0.0596,0.011,0.0219,2370.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-08",6,4.18,198.58,,0.001,0.001,112.688,0.0592,0.01,0.0247,1896.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-09",4,2.18,98.66,,0,0.001,57.098,0.0593,0.005,0.0353,961.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-10",4,2.18,98.7,,0,0.001,56.478,0.0593,0.005,0.034,950.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-11",4,2.22,99.92,,0,0.001,57.301,0.0593,0.006,0.023,964.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-12",4,2.97,137.04,,0,0.001,78.711,0.059,0.007,0.0118,1325.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-13",4,2.95,136.4,,0,0.001,78.83,0.059,0.006,0.011,1326.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-14",5,4.2,194.75,,0.001,0.001,112.32,0.0596,0.009,0.0098,1887.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-15",6,4.95,200.5,,0.001,0.001,119.08,0.0593,0.007,0.0078,2003.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-16",7,4.48,201.82,,0.001,0.001,117.377,0.059,0.01,0.0146,1977.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-17",7,5.72,274.32,,0.001,0.001,157.12,0.0596,0.01,0.0113,2640.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-18",11,9.45,426.48,,0.001,0.001,246.435,0.0591,0.015,0.0152,4146.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-19",4,3.22,141.06,,0,0.001,82.248,0.059,0.009,0.0175,1383.324,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-20",4,1.77,55.38,,0,0.001,34.944,0.059,0.005,0.047,588.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-21",6,4.42,171.53,,0.001,0.001,102.617,0.0597,0.008,0.0177,1725.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-22",4,2.6,118.05,,0,0.001,68.189,0.0593,0.006,0.0135,1148.167,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-23",5,3.23,150.6,,0,0.001,87.497,0.0592,0.008,0.0164,1472.931,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-24",4,2.12,91.1,,0,0.0008,53.12,0.0588,0.005,0.009,893.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-25",3,2.18,96.5,,0,0.001,56.218,0.0593,0.005,0.011,944.904,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-27",4,2.18,98.32,,0,0.001,56.676,0.059,0.005,0.0343,955.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-28",7,5.83,241.75,,0.001,0.001,142.203,0.0596,0.008,0.0073,2390.407,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-29",6,4.47,209.7,,0.001,0.001,121.173,0.059,0.009,0.0172,2039.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-09-30",8,6.94,306.52,,0.001,0.001,178.606,0.059,0.01,0.0083,3007.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-01",6,4.05,116.81,,0,0.001,75.559,0.0593,0.007,0.015,1272.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-02",4,3.12,64.68,,0,0.001,46.412,0.0593,0.004,0.012,780.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-03",4,3.27,102.92,,0,0.001,64.074,0.0593,0.004,0.0083,1078.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-04",5,3.95,146.25,,0,0.001,88.34,0.0592,0.006,0.009,1486.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-05",8,7.17,341.71,,0.001,0.001,197.288,0.0593,0.015,0.0131,3318.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-06",4,3.18,66.68,,0,0.001,47.829,0.0593,0.006,0.0143,804.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-10",3,2.03,41.55,,0,0.001,29.421,0.0597,0.004,0.044,493.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-23",5,1.87,65.39,,0,0.001,40.742,0.0596,0.009,0.0636,685.281,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-25",3,1.69,33.68,,0,0.001,24.557,0.0593,0.004,0.0253,413.247,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-26",3,1.6,31.5,,0,0.001,23.2,0.0593,0.004,0.0273,389.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-27",3,1.72,38.32,,0,0.001,26.512,0.0593,0.002,0.0137,445.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-10-31",3,1.67,33.4,,0,0.001,24.315,0.0597,0.004,0.0213,408.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-01",5,3.25,151.6,,0,0.001,87.995,0.0592,0.007,0.0294,1480.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-02",5,3.17,148.31,,0,0.001,86.018,0.0594,0.007,0.0274,1446.667,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-03",8,6.2,299.7,,0.001,0.001,173.62,0.0591,0.013,0.0206,2921.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-04",11,10.87,532.54,,0.002,0.001,312.885,0.0591,0.026,0.0097,5263.891,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-05",11,9.42,336.16,,0.001,0.001,205.982,0.059,0.014,0.0105,3466.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-06",4,2.83,60.2,,0,0.001,42.561,0.0595,0.005,0.017,715.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-07",2,1.68,34.43,,0,0.001,24.692,0.059,0.005,0.023,415.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-08",3,1.94,38.95,,0,0.001,26.585,0.0593,0.003,0.017,447.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-09",6,3.42,68.66,,0,0.001,49.31,0.0593,0.007,0.0293,828.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-10",4,2.17,69.35,,0,0.001,43.766,0.059,0.005,0.0373,737.773,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-11",3,2.2,44.76,,0,0.001,31.072,0.0593,0.004,0.0203,522.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-14",3,1.9,38.35,,0,0.001,27.99,0.0593,0.004,0.0163,470.667,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-15",4,2.88,96,,0,0.001,60.151,0.0593,0.006,0.0088,1012.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-16",5,3.21,150.34,,0,0.001,88.441,0.059,0.007,0.0266,1488.503,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-17",4,2.45,50.4,,0,0.001,35.955,0.0595,0.004,0.0215,604.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-18",3,1.72,33.96,,0,0.001,25.18,0.06,0.003,0.034,422.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-20",3,1.67,33.36,,0,0.001,23.567,0.0597,0.003,0.0227,396.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-21",3,2.22,44.83,,0,0.001,32.684,0.059,0.004,0.0203,550.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-22",4,2.45,51.4,,0,0.001,36.975,0.0593,0.004,0.0195,623.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-24",3,1.7,34.34,,0,0.001,24.916,0.059,0.003,0.04,419.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-25",3,2.45,51.5,,0,0.001,36.745,0.0597,0.003,0.0083,617.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-29",3,2.17,43.93,,0,0.001,32.398,0.0593,0.004,0.0247,545.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-11-30",4,3.13,93.53,,0,0.001,61.102,0.0598,0.006,0.015,1026.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-01",3,1.65,34.79,,0,0.001,25.203,0.0593,0.004,0.0287,423.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-02",2,1.62,32.16,,0,0.001,23.818,0.0595,0.004,0.019,400.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-03",3,1.92,41.04,,0,0.001,29.328,0.0593,0.004,0.0273,493.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-04",3,1.65,32.63,,0,0.001,24.196,0.059,0.004,0.0373,408.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-05",3,1.9,37.92,,0,0.001,28.036,0.06,0.004,0.0273,470.698,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-06",3,1.68,33.19,,0,0.001,24.529,0.059,0.003,0.022,413.131,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-07",3,1.62,32.19,,0,0.001,23.76,0.059,0.003,0.0293,400.123,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-10",7,6.1,293.95,,0.001,0.001,170.98,0.0591,0.014,0.0109,2877.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-11",3,2.15,53.45,,0,0.001,35.915,0.059,0.004,0.0167,605.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-12",3,2.45,108.5,,0,0.001,64.264,0.059,0.006,0.014,1081.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-14",6,4.7,98.76,,0,0.001,70.301,0.0592,0.009,0.02,1184.035,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-15",3,2.18,47.72,,0,0.001,33.217,0.0593,0.004,0.0213,559.035,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-19",4,2.28,56.88,,0,0.001,38.94,0.0595,0.003,0.0275,654.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-23",2,1.68,36.94,,0,0.001,26.113,0.0595,0.006,0.026,439.735,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Canyon Power Plant",57027,"4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Ammonia Injection",,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-01",24,24,,,0.001,0.0004,118.7,0.0591,0.011,0.0115,2009,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-02",14,14,,,0,0.0001,50.1,0.0595,0.005,0.0115,843.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-03",23,23,,,0,0.0001,127.8,0.0596,0.012,0.0117,2158.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-04",24,24,,,0.001,0.0003,172.2,0.0593,0.016,0.0115,2912.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-05",24,24,,,0.001,0.0004,174.2,0.0594,0.017,0.0116,2943.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-06",19,19,,,0,0.0002,83.5,0.0597,0.008,0.0117,1408.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-07",22,22,,,0.001,0.0004,119.4,0.0596,0.011,0.0116,2013.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-08",9,9,,,0,0.0002,34.4,0.0594,0.003,0.0117,580.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-09",15,15,,,0,0.0003,62,0.0587,0.006,0.0111,1050.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-10",20,20,,,0,0.0002,80.2,0.0594,0.008,0.0115,1354.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-11",18,18,,,0,0.0002,68.3,0.0594,0.007,0.0116,1153,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-12",24,24,,,0,0.0002,128.9,0.0593,0.012,0.0114,2179,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-13",21,21,,,0,0.0003,111.4,0.0596,0.011,0.0116,1879.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-14",22,22,,,0,0.0002,133.7,0.0595,0.013,0.0117,2258.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-15",21,21,,,0,0.0002,97.3,0.0592,0.009,0.0115,1643.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-16",24,24,,,0.001,0.0004,146.3,0.0591,0.014,0.0109,2477.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-17",24,24,,,0,0.0002,121,0.059,0.011,0.0113,2048.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-18",22,22,,,0,0.0002,89,0.0596,0.008,0.0116,1499.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-19",23,23,,,0,0.0002,138.9,0.0591,0.013,0.0114,2350.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-20",24,24,,,0,0.0002,85.4,0.0593,0.008,0.0115,1442.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-23",22,22,,,0,0.0004,118.2,0.0594,0.011,0.0114,1996.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-24",23,23,,,0.001,0.0004,139.6,0.0595,0.013,0.0115,2359.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-25",14,14,,,0,0.0005,90.2,0.0593,0.008,0.0113,1527.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-26",9,9,,,0,0.0007,54.3,0.0588,0.005,0.0112,922.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-27",8,8,,,0,0.0005,53.1,0.059,0.005,0.0109,897.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-28",17,17,,,0,0,60.7,0.0589,0.006,0.0112,1028.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-29",24,24,,,0,0.0001,86,0.0594,0.008,0.011,1452.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-30",16,16,,,0,0.0004,72.1,0.059,0.007,0.0112,1221.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-01",7,7,,,0,0.0004,58.5,0.0593,0.005,0.0109,988.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-04",12,12,,,0,0.0003,77,0.0594,0.007,0.0116,1301.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-05",11,11,,,0,0.0002,45.7,0.0587,0.004,0.0114,774.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-06",17,17,,,0.001,0.0006,130.2,0.0591,0.012,0.0108,2206.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-19",1,1,,,0,0,1.9,0.059,0,0.013,32,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-20",16,16,,,0.001,0.0007,104.7,0.0589,0.01,0.011,1777.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-21",7,7,,,0,0.0006,35.7,0.0593,0.003,0.0109,604.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-22",5,5,,,0,0.0008,30.5,0.059,0.003,0.011,519.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-23",6,6,,,0,0.0005,33.7,0.0593,0.003,0.0112,569.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-24",5,5,,,0,0.0006,29.9,0.059,0.003,0.011,507,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-25",6,6,,,0,0.0007,29.6,0.0592,0.003,0.0105,501.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-26",6,6,,,0,0.0003,27.4,0.06,0.003,0.0115,462.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-27",7,7,,,0,0.0006,34.6,0.0584,0.003,0.0106,586.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-28",9,9,,,0,0.0008,55.8,0.0589,0.005,0.0109,946.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-02-29",6,6,,,0,0.0005,30.9,0.0592,0.003,0.0107,523.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-01",7,7,,,0,0.0006,37.2,0.059,0.003,0.011,630.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-02",6,6,,,0,0.0007,30.3,0.0593,0.003,0.011,511.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-03",6,6,,,0,0.0007,32.5,0.0587,0.003,0.0107,552.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-04",6,6,,,0,0.0005,31.5,0.0587,0.003,0.0112,534.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-05",5,5,,,0,0.0004,26.3,0.059,0.002,0.0108,446.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-06",10,10,,,0,0.0005,50.7,0.0591,0.005,0.0105,857.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-07",10,10,,,0,0.0006,72.7,0.0591,0.007,0.0109,1230.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-10",3,3,,,0,0,6.9,0.0587,0.001,0.0103,117.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-11",10,10,,,0,0.0004,41.7,0.059,0.004,0.0109,709,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-12",7,7,,,0,0.0007,47.2,0.059,0.004,0.0111,798.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-13",8,8,,,0,0.0004,46.6,0.0589,0.004,0.011,792,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-14",16,16,,,0.001,0.0007,131,0.0589,0.012,0.0111,2220.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-15",16,16,,,0.001,0.0009,130.1,0.059,0.012,0.0109,2204.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-16",21,21,,,0.001,0.0004,176.2,0.059,0.016,0.0109,2985.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-17",8,8,,,0,0.0006,38.4,0.0591,0.004,0.011,649.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-18",6,6,,,0,0.0007,35.4,0.0595,0.003,0.0108,596.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-19",12,12,,,0,0.0003,64.4,0.059,0.006,0.0111,1093.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-20",9,9,,,0,0.0007,50.5,0.0591,0.005,0.011,854.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-21",8,8,,,0,0.0005,61.7,0.059,0.006,0.011,1046,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-22",8,8,,,0,0.0006,40.1,0.0589,0.004,0.0108,681.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-23",8,8,,,0,0.0005,55.9,0.0593,0.005,0.0113,946.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-24",9,9,,,0,0.0006,58.6,0.0592,0.005,0.0111,993.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-02",8,8,,,0,0,20.4,0.059,0.002,0.0113,345,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-03",15,15,,,0,0.0005,103.7,0.0591,0.01,0.011,1756,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-04",10,10,,,0,0.0006,64.3,0.0591,0.006,0.0109,1090,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-05",15,15,,,0.001,0.0006,139.7,0.059,0.013,0.0109,2365,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-06",7,7,,,0,0.0003,24.8,0.0593,0.002,0.0103,420,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-07",8,8,,,0,0.0005,57.6,0.059,0.005,0.0111,975,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-08",8,8,,,0,0.0004,63.7,0.0593,0.006,0.0111,1078,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-09",4,4,,,0,0.0005,16.8,0.0585,0.002,0.0115,285,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-10",7,7,,,0,0,19,0.0584,0.002,0.0106,324,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-11",16,16,,,0.001,0.0004,160.5,0.0591,0.015,0.0109,2718,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-12",16,16,,,0.001,0.0004,140.3,0.0591,0.013,0.011,2379,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-13",16,16,,,0.001,0.0006,136.1,0.0589,0.013,0.0111,2308,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-14",12,12,,,0,0.0006,79.3,0.059,0.007,0.0113,1344,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-15",13,13,,,0,0.0005,72.3,0.0592,0.007,0.0112,1223,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-16",7,7,,,0,0.0006,41.1,0.0593,0.004,0.0111,695,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-18",8,8,,,0,0,18.7,0.0595,0.002,0.0111,315,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-19",19,19,,,0.001,0.0004,152.9,0.0593,0.014,0.0112,2588,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-20",10,10,,,0,0.0005,59.9,0.0592,0.006,0.011,1014,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-21",16,16,,,0.001,0.0004,114.6,0.0589,0.011,0.011,1942,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-22",12,12,,,0,0.0003,72.6,0.0586,0.007,0.0112,1232,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-23",15,15,,,0,0.0005,89.4,0.0593,0.008,0.011,1515,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-24",14,14,,,0,0.0004,103.5,0.0591,0.01,0.0111,1752,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-25",12,12,,,0,0.0005,90.7,0.0588,0.009,0.0109,1538,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-26",13,13,,,0.001,0.0004,113.7,0.0591,0.011,0.0108,1925,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-27",11,11,,,0,0.0005,66.4,0.059,0.006,0.0106,1123,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-28",12,12,,,0,0.0003,86.7,0.0593,0.008,0.0112,1469,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-29",14,14,,,0,0.0004,111.9,0.0588,0.01,0.011,1896,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-04-30",17,17,,,0,0.0004,104.2,0.0591,0.01,0.011,1766,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-01",14,14,,,0.001,0.0004,104,0.0594,0.01,0.0109,1762,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-02",14,14,,,0,0.0004,98.1,0.0589,0.009,0.0111,1663,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-03",17,17,,,0.001,0.0005,156.6,0.0588,0.015,0.0108,2656,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-04",13,13,,,0.001,0.0005,100.2,0.0591,0.009,0.011,1697,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-05",13,13,,,0,0.0005,92,0.0588,0.009,0.0109,1559,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-06",14,14,,,0.001,0.0007,103.7,0.0591,0.01,0.0108,1761,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-07",17,17,,,0.001,0.0006,147.3,0.0592,0.014,0.0111,2499,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-08",18,18,,,0.001,0.0005,125.2,0.0587,0.012,0.0109,2123,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-09",17,17,,,0.001,0.0005,156.6,0.059,0.015,0.011,2653,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-10",14,14,,,0.001,0.0005,134.2,0.059,0.013,0.0111,2274,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-11",16,16,,,0,0.0004,105.4,0.059,0.01,0.0109,1786,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-12",14,14,,,0.001,0.0005,108.3,0.0591,0.01,0.0111,1835,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-13",12,12,,,0,0.0005,92.4,0.0591,0.009,0.0108,1564,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-14",17,17,,,0.001,0.0005,161.8,0.0589,0.015,0.011,2741,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-15",12,12,,,0,0.0004,92.5,0.0593,0.009,0.0113,1563,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-16",14,14,,,0.001,0.0006,117.1,0.0592,0.011,0.0111,1982,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-17",15,15,,,0.001,0.0003,155.4,0.0589,0.015,0.0111,2633,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-18",12,12,,,0,0.0003,89.1,0.0588,0.008,0.0116,1510,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-19",12,12,,,0,0.0003,103.8,0.0589,0.01,0.0109,1760,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-20",14,14,,,0.001,0.0006,103.5,0.0593,0.01,0.0108,1751,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-21",14,14,,,0,0.0004,100.7,0.0587,0.009,0.0112,1708,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-22",15,15,,,0.001,0.0005,124.2,0.059,0.012,0.0111,2104,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-23",17,17,,,0.001,0.0006,152.4,0.0589,0.014,0.011,2585,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-24",13,13,,,0.001,0.0005,105,0.0588,0.01,0.0109,1782,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-25",12,12,,,0,0.0005,88.7,0.0588,0.008,0.0113,1503,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-26",13,13,,,0,0.0002,101.2,0.0588,0.01,0.0112,1716,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-27",14,14,,,0.001,0.0005,101.7,0.0587,0.01,0.0112,1726,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-28",15,15,,,0,0.0004,100.6,0.0587,0.009,0.0107,1705,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-29",11,11,,,0,0.0005,66.5,0.0592,0.006,0.0107,1129,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-30",11,11,,,0,0.0005,74,0.0593,0.007,0.0107,1255,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-05-31",15,15,,,0.001,0.0006,101.1,0.0591,0.009,0.0112,1713,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-01",14,14,,,0.001,0.0004,131.7,0.0593,0.012,0.0108,2232,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-02",14,14,,,0.001,0.0006,103.4,0.0593,0.01,0.0108,1752,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-03",16,16,,,0.001,0.0005,125,0.0593,0.012,0.0113,2119,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-04",17,17,,,0,0.0002,117.3,0.059,0.011,0.0109,1989,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-05",16,16,,,0.001,0.0006,107.3,0.0589,0.01,0.011,1817,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-06",18,18,,,0.001,0.0007,161.1,0.0589,0.015,0.0111,2727,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-07",7,7,,,0,0.0004,53.7,0.0591,0.005,0.0109,912,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-08",14,14,,,0.001,0.0005,111.2,0.0589,0.011,0.0114,1887,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-09",13,13,,,0,0.0006,90.8,0.0591,0.008,0.0111,1538,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-10",14,14,,,0,0.0005,97.8,0.0588,0.009,0.0109,1660,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-11",15,15,,,0,0.0005,97,0.0591,0.009,0.0108,1646,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-12",16,16,,,0.001,0.0008,126.7,0.0591,0.012,0.0111,2149,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-13",18,18,,,0,0.0002,62.4,0.0591,0.006,0.0119,1059,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-14",6,6,,,0,0.0007,34.2,0.0593,0.003,0.0115,579,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-15",13,13,,,0,0.0006,84.1,0.0591,0.008,0.0114,1426,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-16",18,18,,,0.001,0.0004,119.7,0.0589,0.011,0.0112,2030,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-17",18,18,,,0,0.0003,94.5,0.0587,0.009,0.0113,1606,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-18",13,13,,,0,0.0004,76.3,0.0588,0.007,0.0113,1296,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-19",14,14,,,0.001,0.0006,108.3,0.0589,0.01,0.0109,1836,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-20",18,18,,,0.001,0.0004,133.1,0.0588,0.012,0.0111,2258,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-21",18,18,,,0,0.0003,84.1,0.0592,0.008,0.0114,1425,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-22",19,19,,,0.001,0.0004,118.9,0.0591,0.011,0.0112,2018,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-23",15,15,,,0.001,0.0006,101.4,0.059,0.009,0.011,1717,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-24",13,13,,,0.001,0.0005,105.1,0.0589,0.01,0.0109,1783,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-25",12,12,,,0,0.0006,73.3,0.0589,0.007,0.0112,1243,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-26",10,10,,,0,0.0006,72.9,0.059,0.007,0.0109,1234,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-27",7,7,,,0,0.0004,64.9,0.0589,0.006,0.011,1101,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-28",10,10,,,0,0.0006,60.3,0.0589,0.006,0.0109,1022,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-29",20,20,,,0.001,0.0005,168.4,0.0591,0.016,0.0111,2852,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-06-30",14,14,,,0.001,0.0005,120.8,0.0588,0.011,0.0109,2047,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-01",17,17,,,0.001,0.0004,129.4,0.059,0.012,0.0114,2191,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-02",21,21,,,0.001,0.0003,182.3,0.0588,0.017,0.0111,3095,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-03",12,12,,,0.001,0.0006,108.6,0.059,0.01,0.011,1842,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-04",7,7,,,0,0.0004,55.2,0.0591,0.005,0.0111,935,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-05",10,10,,,0,0.0007,62.9,0.0589,0.006,0.011,1068,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-06",13,13,,,0.001,0.0003,117.4,0.0589,0.011,0.011,1987,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-07",13,13,,,0,0.0002,100.7,0.0591,0.009,0.0109,1705,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-08",13,13,,,0,0.0004,96.5,0.0588,0.009,0.0109,1634,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-09",13,13,,,0,0.0003,93.4,0.0586,0.009,0.0108,1585,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-10",14,14,,,0.001,0.0004,109.6,0.0589,0.01,0.011,1855,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-11",18,18,,,0.001,0.0006,144.6,0.0592,0.013,0.0111,2449,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-12",5,5,,,0,0.0008,33.4,0.059,0.003,0.0112,567,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-13",17,17,,,0.001,0.0004,137.7,0.0591,0.013,0.0111,2332,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-14",13,13,,,0,0.0004,97.9,0.0591,0.009,0.0113,1659,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-15",12,12,,,0,0.0005,94.7,0.0591,0.009,0.0112,1603,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-16",12,12,,,0,0.0004,70,0.0586,0.006,0.0111,1190,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-17",13,13,,,0.001,0.0005,95.8,0.059,0.009,0.0109,1623,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-18",8,8,,,0,0.0006,54.8,0.0593,0.005,0.011,930,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-19",14,14,,,0.001,0.0008,106.2,0.059,0.01,0.0109,1798,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-20",11,11,,,0,0.0006,68,0.0591,0.006,0.0112,1152,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-21",13,13,,,0.001,0.0006,98.8,0.0588,0.009,0.011,1678,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-22",16,16,,,0.001,0.0008,131.8,0.0591,0.012,0.0111,2230,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-23",15,15,,,0.001,0.0004,126.6,0.0591,0.012,0.0111,2145,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-24",15,15,,,0.001,0.0004,125.1,0.0593,0.012,0.0107,2122,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-25",8,8,,,0,0.0004,67.1,0.0595,0.006,0.0111,1137,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-26",13,13,,,0.001,0.0006,118.2,0.059,0.011,0.0108,2007,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-27",17,17,,,0.001,0.0008,145.9,0.059,0.014,0.0109,2474,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-28",15,15,,,0,0.0005,102,0.0589,0.01,0.0111,1730,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-29",17,17,,,0.001,0.0008,140.2,0.0591,0.013,0.0109,2372,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-30",17,17,,,0.001,0.0008,142,0.0592,0.013,0.0108,2406,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-07-31",17,17,,,0.001,0.0005,124.6,0.0591,0.012,0.0111,2112,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-01",8,8,,,0,0.0006,54.1,0.0593,0.005,0.0109,916,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-02",17,17,,,0.001,0.0004,146.8,0.0591,0.014,0.0109,2487,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-03",17,17,,,0.001,0.0005,138.1,0.059,0.013,0.011,2342,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-04",17,17,,,0.001,0.0005,141,0.0591,0.013,0.011,2389,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-05",17,17,,,0.001,0.0006,147,0.0589,0.014,0.0111,2493,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-06",12,12,,,0,0.0003,77.2,0.0592,0.007,0.011,1308,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-07",17,17,,,0.001,0.0004,136.6,0.0591,0.013,0.011,2315,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-08",8,8,,,0,0.0005,64,0.059,0.006,0.0111,1084,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-09",9,9,,,0,0.0004,67,0.059,0.006,0.0112,1136,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-10",18,18,,,0.001,0.0004,134,0.0591,0.013,0.0109,2274,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-11",20,20,,,0.001,0.0004,146.5,0.059,0.014,0.0113,2486,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-12",20,20,,,0.001,0.0004,135.2,0.0588,0.013,0.0112,2295,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-13",15,15,,,0.001,0.0005,126.7,0.0585,0.012,0.0112,2149,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-14",17,17,,,0.001,0.0004,143.7,0.059,0.013,0.0109,2434,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-15",16,16,,,0.001,0.0006,128.3,0.0591,0.012,0.0111,2176,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-16",16,16,,,0.001,0.0003,162.1,0.0588,0.015,0.011,2748,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-17",16,16,,,0.001,0.0001,165.2,0.0589,0.015,0.0109,2800,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-18",13,13,,,0.001,0.0002,137,0.0591,0.013,0.0111,2322,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-19",14,14,,,0.001,0.0004,145.2,0.0589,0.013,0.0111,2461,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-20",18,18,,,0.001,0.0003,199.7,0.059,0.019,0.0109,3383,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-21",19,19,,,0.001,0.0002,192.8,0.0591,0.018,0.0109,3269,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-22",14,14,,,0.001,0.0004,107.7,0.0592,0.01,0.011,1822,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-23",14,14,,,0.001,0.0004,129.4,0.0589,0.012,0.011,2193,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-24",18,18,,,0.001,0.0004,129.6,0.059,0.012,0.0108,2196,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-25",18,18,,,0.001,0.0004,162.6,0.0591,0.015,0.0109,2755,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-26",16,16,,,0.001,0.0005,154.3,0.0591,0.014,0.0111,2612,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-27",17,17,,,0.001,0.0006,142.5,0.0591,0.013,0.011,2416,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-28",15,15,,,0.001,0.0005,130.1,0.0591,0.012,0.0109,2205,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-29",16,16,,,0.001,0.0005,151.8,0.0591,0.014,0.0109,2570,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-30",7,7,,,0,0.0006,51.2,0.059,0.005,0.011,868,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-08-31",16,16,,,0,0.0004,116.2,0.0591,0.011,0.0112,1968,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-01",16,16,,,0.001,0.0005,152.7,0.0592,0.014,0.011,2583,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-02",16,16,,,0,0.0004,118.6,0.059,0.011,0.0111,2012,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-03",16,16,,,0.001,0.0005,109.4,0.0591,0.01,0.0111,1854,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-04",16,16,,,0,0.0004,109.7,0.0589,0.01,0.0109,1860,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-05",17,17,,,0.001,0.0005,129.4,0.0591,0.012,0.011,2193,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-06",18,18,,,0.001,0.0005,129.6,0.0589,0.012,0.011,2197,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-07",14,14,,,0.001,0.0003,150.6,0.059,0.014,0.011,2551,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-08",21,21,,,0.001,0.0005,184,0.059,0.017,0.011,3115,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-09",19,19,,,0.001,0.0004,128,0.0591,0.012,0.0109,2165,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-10",16,16,,,0.001,0.0004,118.4,0.059,0.011,0.011,2008,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-11",13,13,,,0.001,0.0005,109.9,0.0589,0.01,0.0111,1860,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-12",21,21,,,0.001,0.0004,163.4,0.0589,0.015,0.0112,2768,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-13",11,11,,,0,0.0004,60.2,0.0585,0.006,0.0113,1024,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-14",16,16,,,0.001,0.0003,160.3,0.0593,0.015,0.011,2714,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-15",16,16,,,0.001,0.0002,139.6,0.0589,0.013,0.0111,2366,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-16",16,16,,,0.001,0.0004,141.3,0.0591,0.013,0.0111,2396,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-17",16,16,,,0.001,0.0004,158,0.0591,0.015,0.0111,2678,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-18",14,14,,,0.001,0.0004,130.2,0.059,0.012,0.0109,2208,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-19",17,17,,,0.001,0.0004,168.1,0.0591,0.016,0.0109,2850,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-20",16,16,,,0.001,0.0004,155.9,0.0591,0.015,0.011,2642,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-21",17,17,,,0.001,0.0003,143,0.0591,0.013,0.0111,2423,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-22",17,17,,,0.001,0.0004,171.1,0.0588,0.016,0.0111,2904,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-23",16,16,,,0.001,0.0004,143.8,0.0591,0.013,0.0109,2435,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-24",16,16,,,0.001,0.0004,137.6,0.0588,0.013,0.0109,2332,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-25",17,17,,,0.001,0.0005,147.1,0.0589,0.014,0.0109,2494,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-26",11,11,,,0,0.0004,74.6,0.0591,0.007,0.0112,1264,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-27",16,16,,,0.001,0.0001,177.3,0.0591,0.017,0.0109,3002,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-28",16,16,,,0.001,0.0004,117,0.0586,0.011,0.0109,1984,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-29",16,16,,,0.001,0.0004,126.8,0.0589,0.012,0.0109,2148,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-09-30",16,16,,,0.001,0.0006,133.2,0.0591,0.012,0.011,2255,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-01",16,16,,,0,0.0004,104.1,0.0591,0.01,0.011,1762,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-02",16,16,,,0,0.0004,102.7,0.059,0.01,0.0111,1742,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-03",7,7,,,0,0.0006,44.8,0.0594,0.004,0.0106,759,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-04",7,7,,,0,0.0006,36.4,0.0596,0.003,0.0113,614,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-05",21,21,,,0.001,0.0004,149.2,0.0589,0.014,0.011,2529,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-06",24,24,,,0.001,0.0003,133.3,0.0592,0.013,0.0113,2258,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-07",19,19,,,0.001,0.0005,151.2,0.0591,0.014,0.0112,2559,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-08",11,11,,,0,0.0005,65.8,0.0589,0.006,0.011,1113,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-09",12,12,,,0,0.0004,56.9,0.0593,0.005,0.0109,962,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-10",15,15,,,0.001,0.0004,149.8,0.0589,0.014,0.0109,2539,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-11",7,7,,,0,0.0004,38.2,0.0589,0.004,0.0113,647,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-12",6,6,,,0,0.0003,25.9,0.0593,0.002,0.0107,437,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-13",6,6,,,0,0.0005,26.1,0.0593,0.002,0.011,441,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-19",1,1,,,0,0,1.5,0.06,0,0.012,25,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-20",3,3,,,0,0,8,0.0593,0.001,0.01,135,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-21",7,7,,,0,0.0003,33.8,0.0583,0.003,0.0109,575,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-22",6,6,,,0,0.0002,25.8,0.0593,0.002,0.0117,435,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-23",8,8,,,0,0.0004,31.1,0.0591,0.003,0.0111,528,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-24",10,10,,,0,0.0007,52.5,0.0586,0.005,0.011,894,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-25",8,8,,,0,0.0001,39,0.0593,0.004,0.0111,660,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-26",6,6,,,0,0.0007,28.9,0.0582,0.003,0.0105,490,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-29",2,2,,,0,0,3.5,0.058,0,0.009,60,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-30",8,8,,,0,0.0006,39.8,0.0593,0.004,0.0109,672,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-10-31",7,7,,,0,0.0006,29.9,0.059,0.003,0.011,507,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-01",5,5,,,0,0.0004,27.2,0.059,0.003,0.011,461,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-02",6,6,,,0,0.0007,28.4,0.0592,0.003,0.011,480,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-03",6,6,,,0,0.0003,28.5,0.059,0.003,0.011,483,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-04",5,5,,,0,0.0006,26.1,0.0594,0.002,0.0112,442,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-05",5,5,,,0,0.0004,24,0.0592,0.002,0.0112,406,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-06",7,7,,,0,0.0006,27.5,0.0594,0.003,0.0109,466,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-07",7,7,,,0,0.0006,43.2,0.0591,0.004,0.011,731,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-08",7,7,,,0,0.0006,32.8,0.0591,0.003,0.0113,557,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-09",5,5,,,0,0.0006,27.8,0.059,0.003,0.0108,471,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-10",5,5,,,0,0.0006,28.3,0.0592,0.003,0.0108,481,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-11",5,5,,,0,0.0004,26.6,0.0592,0.002,0.0108,450,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-12",5,5,,,0,0.0004,24.7,0.059,0.002,0.0108,419,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-13",5,5,,,0,0.0004,22.8,0.0592,0.002,0.011,387,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-14",5,5,,,0,0.0004,25.3,0.0594,0.002,0.0106,427,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-15",5,5,,,0,0.0004,25,0.0592,0.002,0.0108,423,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-16",5,5,,,0,0.0004,24,0.0592,0.002,0.0108,407,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-17",5,5,,,0,0.0004,24.4,0.0588,0.002,0.0108,414,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-18",12,12,,,0,0.0003,34.5,0.0585,0.003,0.0112,584,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-19",8,8,,,0,0.0003,32.5,0.059,0.003,0.011,550,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-20",7,7,,,0,0.0006,38,0.059,0.004,0.011,643,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-21",5,5,,,0,0.0006,27,0.0588,0.003,0.011,459,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-22",7,7,,,0,0.0006,32.9,0.0593,0.003,0.0113,556,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-23",6,6,,,0,0.0005,27.1,0.0597,0.003,0.0108,457,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-24",5,5,,,0,0.0006,24.1,0.0588,0.002,0.011,409,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-25",5,5,,,0,0.0006,22.8,0.0594,0.002,0.011,385,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-26",5,5,,,0,0.0004,21.7,0.0588,0.002,0.0108,369,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-27",5,5,,,0,0.0006,23.9,0.0588,0.002,0.0112,405,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-28",5,5,,,0,0.0006,24,0.0592,0.002,0.0108,407,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-29",5,5,,,0,0.0004,23.2,0.059,0.002,0.0108,394,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-11-30",7,7,,,0,0.0006,37.8,0.0591,0.004,0.0113,639,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-01",5,5,,,0,0.0006,26.4,0.0586,0.002,0.0112,449,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-02",6,6,,,0,0.0007,33.5,0.0592,0.003,0.0107,568,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-03",5,5,,,0,0.0006,22.2,0.0592,0.002,0.0114,375,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-04",5,5,,,0,0.0006,22,0.0588,0.002,0.0116,375,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-05",5,5,,,0,0.0004,20.2,0.0592,0.002,0.0112,343,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-06",5,5,,,0,0.0006,28,0.0592,0.003,0.0112,476,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-07",9,9,,,0,0.0006,59.3,0.0589,0.005,0.0109,1010,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-08",6,6,,,0,0.0005,40.1,0.0585,0.004,0.0105,681,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-09",5,5,,,0,0.0006,26.8,0.0592,0.003,0.0112,453,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-10",5,5,,,0,0.0006,25.9,0.0586,0.003,0.0112,440,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-11",6,6,,,0,0.0007,35.5,0.0592,0.003,0.0108,600,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-12",6,6,,,0,0.0005,26.8,0.0592,0.003,0.011,454,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-13",5,5,,,0,0.0006,22.9,0.0592,0.002,0.011,389,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-19",9,9,,,0,0.0004,50,0.0592,0.005,0.011,846,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-20",6,6,,,0,0.0005,25.9,0.0592,0.002,0.0115,437,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-21",6,6,,,0,0.0002,22,0.0585,0.002,0.011,373,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-22",7,7,,,0,0.0004,33.2,0.059,0.003,0.0113,562,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-23",6,6,,,0,0.0003,27.4,0.0592,0.003,0.0107,465,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-24",6,6,,,0,0.0005,22.6,0.0593,0.002,0.011,382,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-25",8,8,,,0,0.0006,48.1,0.0588,0.005,0.0114,815,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-26",6,6,,,0,0.0007,33.3,0.0588,0.003,0.0108,565,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-27",5,5,,,0,0.0004,20.4,0.0592,0.002,0.011,345,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-28",5,5,,,0,0.0006,30,0.0592,0.003,0.011,509,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-29",10,10,,,0,0.0007,57.7,0.0595,0.005,0.0113,975,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-30",12,12,,,0,0.0005,91.2,0.0593,0.009,0.011,1544,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 2",57073,"BLR1",,"2020-12-31",7,7,,,0,0.0004,39.8,0.0593,0.004,0.0111,674,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-01",14,14,,,0.001,0.0006,100.2,0.0589,0.009,0.0107,1700.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-02",6,6,,,0,0.0005,27.5,0.0585,0.003,0.0103,465.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-03",9,9,,,0,0.0007,51.1,0.059,0.005,0.0107,865.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-04",8,8,,,0,0.0006,41.8,0.0589,0.004,0.011,708.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-05",8,8,,,0,0.0006,46.7,0.0591,0.004,0.0113,789,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-06",7,7,,,0,0.0004,34.6,0.0594,0.003,0.0116,587.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-07",8,8,,,0,0.0005,39,0.0595,0.004,0.0113,659.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-08",6,6,,,0,0.0005,27.9,0.0592,0.003,0.011,471.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-09",8,8,,,0,0.0006,38.5,0.0591,0.004,0.0106,649.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-10",6,6,,,0,0.0005,29.7,0.0592,0.003,0.0112,503.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-11",7,7,,,0,0.0006,33.5,0.0586,0.003,0.0107,568,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-12",7,7,,,0,0.0007,46.1,0.0589,0.004,0.0111,780.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-13",7,7,,,0,0.0007,39.2,0.059,0.004,0.0109,662.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-14",6,6,,,0,0.0007,39.4,0.0592,0.004,0.0108,666.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-15",11,11,,,0,0.0002,40,0.0587,0.004,0.0115,678.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-16",19,19,,,0,0.0002,62.7,0.0593,0.006,0.0111,1059.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-17",10,10,,,0,0.0006,53,0.0589,0.005,0.0107,900,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-18",6,6,,,0,0.0003,24.2,0.0587,0.002,0.0115,409,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-19",7,7,,,0,0.0004,39.4,0.0584,0.004,0.0117,669.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-20",7,7,,,0,0.0003,50.1,0.0584,0.005,0.0114,850,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-21",6,6,,,0,0.0005,28.3,0.0587,0.003,0.0108,481.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-22",7,7,,,0,0.0003,41.1,0.0594,0.004,0.0117,697.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-07",14,14,,,0,0.0004,65.4,0.0588,0.006,0.0114,1109.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-08",7,7,,,0,0.0004,27.2,0.0586,0.002,0.0107,460.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-09",10,10,,,0,0.0009,74.9,0.0589,0.007,0.0111,1271.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-10",14,14,,,0.001,0.0008,106.6,0.0591,0.01,0.011,1804.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-11",8,8,,,0,0.0004,45.9,0.0585,0.004,0.0113,778.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-12",15,15,,,0.001,0.0006,108.4,0.0587,0.01,0.011,1840.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-13",13,13,,,0.001,0.0006,84.8,0.0591,0.008,0.0109,1437.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-14",12,12,,,0,0.0004,77.6,0.0585,0.007,0.0108,1317.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-15",14,14,,,0.001,0.0004,104.5,0.0594,0.01,0.0116,1769.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-16",15,15,,,0,0.0003,96.7,0.0589,0.009,0.0112,1639.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-17",11,11,,,0,0.0007,74,0.0593,0.007,0.0112,1253.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-18",14,14,,,0.001,0.0003,128.9,0.0589,0.012,0.0109,2183.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-19",7,7,,,0,0.0004,23.9,0.0591,0.002,0.011,405.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-20",11,11,,,0,0.0006,69.4,0.0592,0.006,0.0109,1175.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-21",12,12,,,0,0.0006,66.6,0.0593,0.006,0.0109,1129,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-22",5,5,,,0,0.0004,26.8,0.059,0.003,0.0112,454.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-23",11,11,,,0,0.0005,77.9,0.0594,0.007,0.0115,1320.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-24",11,11,,,0,0.0006,68.5,0.0588,0.006,0.011,1161.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-25",13,13,,,0,0.0003,70.3,0.059,0.007,0.011,1189.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-26",17,17,,,0,0.0002,68.9,0.0589,0.006,0.0109,1167,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-27",16,16,,,0,0.0003,76.4,0.0589,0.007,0.0108,1296.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-28",12,12,,,0,0.0004,88.2,0.0589,0.008,0.0108,1498.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-02-29",4,4,,,0,0.0003,9.3,0.0605,0.001,0.0115,156.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-01",7,7,,,0,0.0006,37.4,0.0589,0.003,0.0107,634.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-02",11,11,,,0,0.0004,60.3,0.0589,0.006,0.0111,1022.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-03",11,11,,,0,0.0005,60.4,0.0591,0.006,0.011,1020.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-04",10,10,,,0,0.0003,62.7,0.0591,0.006,0.0108,1062.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-05",15,15,,,0.001,0.0007,123.1,0.0591,0.011,0.0107,2085.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-06",13,13,,,0.001,0.0008,116.4,0.0591,0.011,0.011,1973.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-07",11,11,,,0,0.0004,66.9,0.0588,0.006,0.0111,1135.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-08",11,11,,,0,0.0005,62,0.0591,0.006,0.0114,1053.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-09",12,12,,,0,0.0008,65.9,0.0589,0.006,0.0113,1115.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-10",3,3,,,0,0,3.8,0.061,0,0.0123,62.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-11",13,13,,,0,0.0002,67.9,0.0585,0.006,0.0112,1152.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-12",7,7,,,0,0.0006,36.9,0.0586,0.003,0.0114,626.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-13",10,10,,,0,0.0004,33.8,0.0594,0.003,0.0107,570.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-14",15,15,,,0.001,0.0005,118.6,0.0587,0.011,0.0109,2010.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-15",16,16,,,0.001,0.0008,117.1,0.0589,0.011,0.011,1984.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-16",17,17,,,0.001,0.0005,114.4,0.0589,0.011,0.0109,1939.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-17",6,6,,,0,0.0002,18.8,0.0588,0.002,0.0115,318.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-18",6,6,,,0,0.0007,33.2,0.0585,0.003,0.0108,564.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-19",8,8,,,0,0.0006,41.4,0.0586,0.004,0.0111,700.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-20",10,10,,,0,0.0005,50.9,0.0595,0.005,0.0115,860.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-21",8,8,,,0,0.0005,41.4,0.0591,0.004,0.011,700,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-22",8,8,,,0,0.0004,33.6,0.059,0.003,0.011,569.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-23",8,8,,,0,0.0005,48.1,0.0589,0.004,0.0111,815.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-24",11,11,,,0,0.0004,53.5,0.0595,0.005,0.0108,905.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-25",7,7,,,0,0.0007,39.2,0.059,0.004,0.0113,662.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-26",13,13,,,0,0.0005,72.7,0.0592,0.007,0.0108,1233.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-27",17,17,,,0.001,0.0008,117.9,0.0589,0.011,0.0112,1997.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-28",20,20,,,0.001,0.0004,121.3,0.0589,0.011,0.0111,2057.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-29",24,24,,,0,0.0003,117,0.059,0.011,0.011,1984.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-30",20,20,,,0,0.0003,104.9,0.0592,0.01,0.0109,1777.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-03-31",24,24,,,0.001,0.0005,148.2,0.0591,0.014,0.0106,2517.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-01",20,20,,,0,0.0003,104.7,0.0591,0.01,0.011,1771,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-02",18,18,,,0,0.0004,94.9,0.0589,0.009,0.0109,1609,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-03",17,17,,,0,0.0005,83.8,0.0593,0.008,0.0109,1415,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-04",18,18,,,0,0.0004,99.2,0.059,0.009,0.0111,1681,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-05",24,24,,,0.001,0.0002,180.6,0.0591,0.017,0.011,3060,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-06",24,24,,,0,0.0001,70.6,0.0596,0.007,0.011,1185,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-07",24,24,,,0,0.0002,91.5,0.0596,0.009,0.011,1540,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-08",24,24,,,0,0.0002,105.7,0.0597,0.01,0.011,1778,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-09",15,15,,,0,0.0003,69.2,0.0593,0.006,0.0108,1170,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-10",7,7,,,0,0,19,0.0593,0.002,0.0116,321,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-11",16,16,,,0.001,0.0004,144.9,0.0589,0.013,0.011,2458,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-12",15,15,,,0.001,0.0006,100.5,0.0591,0.009,0.0111,1704,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-13",16,16,,,0,0.0004,100.7,0.059,0.009,0.011,1708,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-14",12,12,,,0,0.0003,86.8,0.0589,0.008,0.011,1471,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-15",14,14,,,0,0.0005,78.1,0.0589,0.007,0.0112,1326,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-16",17,17,,,0,0.0005,98.8,0.0592,0.009,0.0111,1672,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-17",12,12,,,0.001,0.0008,102.1,0.059,0.009,0.0109,1730,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-18",10,10,,,0,0.0005,68.9,0.0589,0.006,0.0109,1168,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-19",16,16,,,0.001,0.0006,125,0.059,0.012,0.0111,2120,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-20",9,9,,,0,0.0004,44.3,0.059,0.004,0.0111,750,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-21",13,13,,,0,0.0005,88.4,0.059,0.008,0.0107,1496,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-22",11,11,,,0,0.0004,71.7,0.0595,0.007,0.011,1214,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-23",12,12,,,0,0.0006,69.8,0.0593,0.007,0.011,1181,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-24",12,12,,,0,0.0004,83.4,0.0593,0.008,0.0108,1411,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-25",10,10,,,0,0.0004,76.6,0.0591,0.007,0.011,1299,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-26",14,14,,,0.001,0.0003,127.8,0.0587,0.012,0.0112,2166,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-27",7,7,,,0,0.0006,33.1,0.0587,0.003,0.0107,561,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-28",9,9,,,0,0.0003,40.6,0.0584,0.004,0.0112,690,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-29",14,14,,,0,0.0004,69.6,0.0591,0.006,0.011,1178,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-04-30",21,21,,,0,0.0002,82.5,0.0592,0.008,0.0109,1396,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-01",20,20,,,0,0.0004,101.9,0.059,0.01,0.0111,1727,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-02",20,20,,,0.001,0.0004,116.3,0.059,0.011,0.0111,1970,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-03",24,24,,,0.001,0.0004,168.6,0.059,0.016,0.011,2857,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-04",20,20,,,0.001,0.0004,111.5,0.0592,0.01,0.0112,1888,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-05",16,16,,,0,0.0004,93.2,0.0588,0.009,0.0108,1578,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-06",14,14,,,0,0.0005,96.3,0.0589,0.009,0.0114,1634,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-07",17,17,,,0.001,0.0006,140.1,0.0589,0.013,0.0112,2373,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-08",16,16,,,0,0.0004,102.3,0.0588,0.009,0.0109,1734,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-09",17,17,,,0.001,0.0005,142.8,0.0588,0.013,0.0111,2422,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-10",14,14,,,0.001,0.0008,111.3,0.059,0.01,0.0108,1887,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-11",17,17,,,0.001,0.0005,106.4,0.0588,0.01,0.0112,1804,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-12",7,7,,,0,0.0001,34.5,0.059,0.003,0.0107,585,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-14",20,20,,,0.001,0.0005,163.3,0.0592,0.015,0.0111,2761,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-15",13,13,,,0,0.0004,95.6,0.0589,0.009,0.0109,1620,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-16",14,14,,,0.001,0.0007,112.6,0.0588,0.011,0.0111,1910,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-17",16,16,,,0.001,0.0004,154,0.0591,0.015,0.0111,2611,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-18",12,12,,,0,0.0005,87.6,0.0588,0.008,0.0109,1483,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-19",7,7,,,0,0.0004,32.2,0.0594,0.003,0.0113,545,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-20",13,13,,,0,0.0005,91.7,0.0592,0.009,0.0109,1555,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-21",13,13,,,0,0.0004,96.1,0.0589,0.009,0.0111,1629,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-22",15,15,,,0,0.0004,104.8,0.0589,0.01,0.0111,1777,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-23",17,17,,,0.001,0.0005,124.2,0.0592,0.012,0.0111,2102,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-24",13,13,,,0.001,0.0007,87.4,0.0585,0.008,0.0107,1484,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-25",12,12,,,0,0.0006,83.5,0.0588,0.008,0.0109,1419,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-26",14,14,,,0,0.0005,91.9,0.0588,0.009,0.0111,1558,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-27",16,16,,,0.001,0.0005,100.3,0.059,0.009,0.0109,1698,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-28",16,16,,,0.001,0.0005,125,0.0592,0.012,0.0111,2118,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-29",8,8,,,0,0.0005,47.7,0.0585,0.005,0.0113,808,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-30",11,11,,,0,0.0006,78.4,0.059,0.007,0.0112,1327,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-05-31",12,12,,,0.001,0.0008,86.8,0.0591,0.008,0.011,1471,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-01",13,13,,,0.001,0.0008,118.5,0.059,0.011,0.011,2009,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-02",12,12,,,0,0.0008,72.4,0.0589,0.007,0.0111,1231,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-03",16,16,,,0.001,0.0005,93,0.059,0.009,0.0109,1576,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-04",16,16,,,0.001,0.0004,124.3,0.0591,0.012,0.011,2105,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-05",16,16,,,0.001,0.0006,106.1,0.0588,0.01,0.0108,1803,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-06",17,17,,,0.001,0.0006,159.3,0.0588,0.015,0.0109,2699,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-07",11,11,,,0,0.0004,82.4,0.059,0.008,0.011,1396,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-08",13,13,,,0,0.0003,103.8,0.0592,0.01,0.0108,1758,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-09",14,14,,,0.001,0.0005,103,0.059,0.01,0.0107,1746,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-10",13,13,,,0,0.0005,89.4,0.0592,0.008,0.0112,1516,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-11",12,12,,,0,0.0004,69.3,0.0588,0.007,0.0111,1176,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-12",18,18,,,0.001,0.0005,139.6,0.0589,0.013,0.011,2372,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-13",18,18,,,0.001,0.0006,142.2,0.0593,0.013,0.0112,2410,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-14",14,14,,,0.001,0.0006,94.2,0.0589,0.009,0.0114,1601,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-15",14,14,,,0.001,0.0006,119.8,0.059,0.011,0.0109,2029,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-17",8,8,,,0,0,17.5,0.0588,0.002,0.0105,297,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-18",14,14,,,0,0.0004,99.8,0.0589,0.009,0.0109,1690,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-19",13,13,,,0.001,0.0006,106.2,0.0589,0.01,0.0109,1799,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-20",15,15,,,0.001,0.0005,126.3,0.0589,0.012,0.011,2143,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-21",13,13,,,0,0.0005,100.2,0.0589,0.009,0.011,1702,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-22",13,13,,,0.001,0.0005,111.2,0.0591,0.01,0.0109,1883,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-23",14,14,,,0.001,0.0006,102.5,0.0589,0.01,0.0108,1740,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-24",14,14,,,0.001,0.0005,123,0.0593,0.011,0.0111,2083,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-25",12,12,,,0,0.0004,92.2,0.0588,0.009,0.011,1566,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-26",12,12,,,0.001,0.0006,96.5,0.0588,0.009,0.0108,1635,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-27",14,14,,,0.001,0.0005,117.4,0.0589,0.011,0.0111,1992,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-28",9,9,,,0,0.0008,65,0.0596,0.006,0.0112,1100,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-29",18,18,,,0.001,0.0005,159.5,0.0591,0.015,0.011,2701,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-06-30",14,14,,,0.001,0.0005,95.7,0.0591,0.009,0.0108,1622,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-01",17,17,,,0.001,0.0004,155.5,0.0592,0.015,0.0111,2635,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-02",17,17,,,0.001,0.0003,160.9,0.0591,0.015,0.011,2727,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-03",14,14,,,0,0.0005,99.9,0.0589,0.009,0.011,1692,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-04",12,12,,,0,0.0004,93.4,0.0588,0.009,0.011,1583,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-05",14,14,,,0.001,0.0005,101.5,0.0589,0.009,0.0111,1719,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-06",14,14,,,0,0.0004,107.5,0.0591,0.01,0.0108,1820,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-07",13,13,,,0.001,0.0005,99.7,0.0589,0.009,0.011,1689,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-08",16,16,,,0,0.0004,97.4,0.0593,0.009,0.0109,1646,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-09",17,17,,,0.001,0.0005,147.3,0.0591,0.014,0.0111,2499,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-10",15,15,,,0.001,0.0005,110.7,0.0591,0.01,0.011,1877,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-11",17,17,,,0.001,0.0008,141.8,0.059,0.013,0.011,2403,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-12",12,12,,,0,0.0006,76.4,0.0588,0.007,0.0108,1298,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-13",17,17,,,0,0.0003,101.5,0.0591,0.01,0.0114,1723,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-14",15,15,,,0.001,0.0005,108.4,0.0589,0.01,0.0109,1837,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-15",12,12,,,0,0.0004,85.4,0.0591,0.008,0.0112,1447,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-16",13,13,,,0,0.0004,83.4,0.0592,0.008,0.0113,1414,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-17",14,14,,,0.001,0.0006,105.8,0.0587,0.01,0.011,1796,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-18",13,13,,,0,0.0005,94.2,0.0592,0.009,0.0112,1599,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-19",14,14,,,0.001,0.0006,108.7,0.0588,0.01,0.0111,1841,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-20",13,13,,,0.001,0.0007,87.2,0.059,0.008,0.0109,1479,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-21",15,15,,,0.001,0.0005,129.3,0.0593,0.012,0.0111,2187,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-22",11,11,,,0,0.0005,78.4,0.0587,0.007,0.0111,1330,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-23",14,14,,,0,0.0003,107.6,0.0586,0.01,0.0112,1823,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-24",14,14,,,0.001,0.0004,106.6,0.0595,0.01,0.0109,1807,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-25",14,14,,,0.001,0.0005,105,0.0589,0.01,0.0108,1782,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-26",13,13,,,0.001,0.0006,111.5,0.0593,0.01,0.0112,1888,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-27",18,18,,,0.001,0.0004,169,0.0588,0.016,0.0109,2866,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-28",14,14,,,0.001,0.0006,94.6,0.0586,0.009,0.0107,1606,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-29",14,14,,,0,0.0004,102,0.059,0.009,0.0109,1729,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-30",17,17,,,0.001,0.0005,120.9,0.0592,0.011,0.0111,2049,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-07-31",15,15,,,0.001,0.0005,99.4,0.0589,0.009,0.0113,1687,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-01",13,13,,,0,0.0006,79.8,0.0592,0.007,0.0108,1350,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-02",17,17,,,0.001,0.0006,144.7,0.0592,0.014,0.011,2449,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-03",17,17,,,0.001,0.0006,131.8,0.0592,0.012,0.0112,2234,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-04",15,15,,,0.001,0.0004,121.1,0.0591,0.011,0.0111,2051,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-05",18,18,,,0.001,0.0004,132.7,0.0586,0.012,0.0112,2251,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-06",13,13,,,0,0.0005,100,0.0588,0.009,0.0114,1696,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-07",16,16,,,0.001,0.0004,115.9,0.0593,0.011,0.0112,1965,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-08",13,13,,,0.001,0.0005,97.6,0.059,0.009,0.0111,1655,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-09",14,14,,,0.001,0.0005,106.3,0.0589,0.01,0.0111,1802,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-10",14,14,,,0,0.0003,102,0.0594,0.01,0.0111,1726,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-11",17,17,,,0.001,0.0003,136,0.059,0.013,0.011,2310,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-12",13,13,,,0,0.0005,91.1,0.059,0.008,0.011,1542,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-13",16,16,,,0.001,0.0005,116.6,0.0588,0.011,0.0112,1978,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-14",18,18,,,0.001,0.0004,151.4,0.0591,0.014,0.0111,2566,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-15",13,13,,,0.001,0.0005,109.6,0.0591,0.01,0.011,1859,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-16",15,15,,,0.001,0.0008,128.2,0.0591,0.012,0.0111,2171,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-17",16,16,,,0.001,0.0005,155.1,0.059,0.014,0.0111,2628,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-18",13,13,,,0.001,0.0003,132.9,0.059,0.012,0.0109,2254,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-19",13,13,,,0.001,0.0003,136,0.059,0.013,0.011,2307,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-20",18,18,,,0.001,0.0003,185.2,0.059,0.017,0.0109,3141,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-21",18,18,,,0.001,0.0003,179.2,0.059,0.017,0.0109,3038,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-22",13,13,,,0.001,0.0005,94.6,0.0591,0.009,0.011,1604,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-23",14,14,,,0.001,0.0005,121.4,0.0589,0.011,0.0112,2059,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-24",12,12,,,0,0.0003,72.7,0.0589,0.007,0.0109,1232,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-25",18,18,,,0.001,0.0004,154.4,0.0591,0.014,0.0109,2615,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-26",17,17,,,0.001,0.0005,158.2,0.0591,0.015,0.0109,2680,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-27",18,18,,,0.001,0.0004,173,0.0591,0.016,0.0111,2932,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-28",16,16,,,0.001,0.0008,133.9,0.0591,0.013,0.0111,2269,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-29",16,16,,,0.001,0.0007,131.3,0.0589,0.012,0.0111,2224,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-30",13,13,,,0,0.0005,80.1,0.0588,0.007,0.0111,1358,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-08-31",13,13,,,0.001,0.0006,105.2,0.0591,0.01,0.0111,1784,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-01",18,18,,,0.001,0.0005,156,0.0594,0.015,0.0109,2639,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-02",16,16,,,0.001,0.0005,127.2,0.0588,0.012,0.0109,2157,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-03",8,8,,,0,0.0008,60.5,0.059,0.006,0.0111,1025,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-04",13,13,,,0,0.0005,96.6,0.059,0.009,0.0109,1636,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-05",16,16,,,0.001,0.0006,112.8,0.0591,0.011,0.0111,1909,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-06",17,17,,,0.001,0.0005,129.9,0.0589,0.012,0.0109,2202,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-07",15,15,,,0.001,0.0003,149,0.0593,0.014,0.0111,2528,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-08",14,14,,,0,0.0003,80,0.0588,0.008,0.0111,1358,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-09",15,15,,,0.001,0.0006,116.1,0.0589,0.011,0.0109,1968,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-10",14,14,,,0.001,0.0004,108.2,0.0587,0.01,0.0111,1834,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-11",16,16,,,0.001,0.0004,131.1,0.059,0.012,0.0108,2224,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-12",16,16,,,0.001,0.0006,158,0.059,0.015,0.011,2680,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-13",13,13,,,0.001,0.0005,104.3,0.0589,0.01,0.0107,1767,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-14",14,14,,,0.001,0.0003,139.4,0.0594,0.013,0.0111,2362,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-15",16,16,,,0.001,0.0003,158.3,0.059,0.015,0.0109,2683,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-16",16,16,,,0.001,0.0003,154.9,0.0589,0.015,0.011,2626,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-17",16,16,,,0.001,0.0004,149.3,0.0593,0.014,0.0109,2531,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-18",16,16,,,0.001,0.0004,154.4,0.059,0.014,0.011,2617,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-19",17,17,,,0.001,0.0004,157.9,0.0589,0.015,0.0112,2676,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-20",17,17,,,0.001,0.0005,145.6,0.0587,0.014,0.0109,2470,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-21",16,16,,,0.001,0.0004,166.1,0.059,0.016,0.011,2814,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-22",17,17,,,0.001,0.0005,152.5,0.0592,0.014,0.0111,2587,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-23",14,14,,,0.001,0.0004,117.9,0.059,0.011,0.0109,1998,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-24",15,15,,,0.001,0.0005,123,0.0591,0.011,0.0109,2085,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-25",16,16,,,0.001,0.0006,149.6,0.0588,0.014,0.0109,2538,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-26",17,17,,,0.001,0.0005,124.3,0.0589,0.012,0.0109,2106,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-27",16,16,,,0.001,0.0003,159.8,0.0591,0.015,0.011,2707,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-28",15,15,,,0.001,0.0005,110.6,0.0589,0.01,0.0113,1876,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-29",14,14,,,0.001,0.0004,108,0.0592,0.01,0.0107,1831,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-09-30",16,16,,,0.001,0.0005,123.3,0.059,0.012,0.0111,2090,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-01",14,14,,,0,0.0005,88.2,0.0589,0.008,0.0114,1495,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-02",12,12,,,0,0.0005,75.3,0.0592,0.007,0.0116,1275,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-03",13,13,,,0,0.0005,93.9,0.0591,0.009,0.0113,1590,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-04",14,14,,,0.001,0.0005,98.5,0.059,0.009,0.0109,1668,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-05",15,15,,,0.001,0.0006,128.3,0.0593,0.012,0.0111,2172,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-06",14,14,,,0,0.0006,92.3,0.0591,0.009,0.011,1562,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-07",15,15,,,0.001,0.0005,111.8,0.059,0.01,0.0108,1896,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-08",8,8,,,0,0.0008,59.1,0.0589,0.006,0.011,1002,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-09",13,13,,,0,0.0005,62,0.059,0.006,0.011,1051,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-10",16,16,,,0.001,0.0006,131.2,0.0586,0.012,0.0113,2225,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-11",6,6,,,0,0.0008,32.4,0.0588,0.003,0.0112,550,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-12",6,6,,,0,0.0005,28.6,0.0592,0.003,0.011,484,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-13",7,7,,,0,0.0004,26.7,0.0589,0.003,0.0117,452,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-14",5,5,,,0,0.0008,24.4,0.0588,0.002,0.011,415,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-15",7,7,,,0,0.0004,29.3,0.0587,0.003,0.011,498,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-16",7,7,,,0,0.0006,28.9,0.0599,0.003,0.011,489,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-17",7,7,,,0,0.0006,35.2,0.0584,0.003,0.011,599,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-18",6,6,,,0,0.0007,27.2,0.0582,0.003,0.0107,464,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-19",6,6,,,0,0.0005,31.2,0.059,0.003,0.0112,527,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-20",6,6,,,0,0.0005,30.8,0.0588,0.003,0.0108,521,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-21",6,6,,,0,0.0005,28.3,0.0588,0.003,0.011,479,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-22",5,5,,,0,0.0006,27.6,0.059,0.003,0.011,469,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-23",7,7,,,0,0.0004,27.5,0.0587,0.003,0.0111,465,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-24",9,9,,,0,0.0008,45.3,0.0588,0.004,0.0111,769,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-25",5,5,,,0,0.0004,25,0.0592,0.002,0.0112,423,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-26",5,5,,,0,0.0002,29,0.0586,0.003,0.011,493,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-27",6,6,,,0,0.0003,26.2,0.0595,0.002,0.0112,445,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-28",5,5,,,0,0.0004,22.9,0.0592,0.002,0.0118,389,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-29",5,5,,,0,0.0004,21.8,0.0588,0.002,0.0114,370,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-30",7,7,,,0,0.0006,31.1,0.0586,0.003,0.0104,529,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-10-31",7,7,,,0,0.0003,28.1,0.0589,0.003,0.0101,477,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-01",4,4,,,0,0.0008,22.9,0.0588,0.002,0.0105,388,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-02",6,6,,,0,0.0007,30.5,0.0593,0.003,0.0113,516,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-03",7,7,,,0,0.0004,29.7,0.059,0.003,0.0107,503,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-04",5,5,,,0,0.0004,21.7,0.0592,0.002,0.011,368,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-05",5,5,,,0,0.0004,23.5,0.0588,0.002,0.011,400,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-06",7,7,,,0,0.0006,28.5,0.0586,0.003,0.0113,486,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-07",6,6,,,0,0.0007,38.3,0.0585,0.004,0.0113,650,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-08",7,7,,,0,0.0006,36.2,0.059,0.003,0.011,615,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-11",8,8,,,0,0.0004,25.9,0.0574,0.002,0.0103,442,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-12",5,5,,,0,0.0006,26.5,0.0592,0.002,0.0108,448,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-13",6,6,,,0,0.0003,25.3,0.0597,0.002,0.0115,428,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-14",6,6,,,0,0.0005,29.1,0.0585,0.003,0.0108,495,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-15",5,5,,,0,0.0006,26.9,0.0592,0.003,0.0112,455,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-16",5,5,,,0,0.0008,29.1,0.0592,0.003,0.0112,493,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-18",8,8,,,0,0.0003,22.8,0.0598,0.002,0.0106,384,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-19",12,12,,,0,0.0003,79.2,0.0593,0.007,0.0106,1343,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-20",7,7,,,0,0.0007,41.2,0.0593,0.004,0.0111,697,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-21",6,6,,,0,0.0005,30.2,0.0585,0.003,0.0115,513,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-22",7,7,,,0,0.0006,41.9,0.0587,0.004,0.0111,709,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-23",6,6,,,0,0.0005,26.8,0.0588,0.003,0.0118,454,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-24",6,6,,,0,0.0005,26.8,0.0588,0.002,0.0107,455,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-25",6,6,,,0,0.0005,27.8,0.0583,0.003,0.011,472,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-26",6,6,,,0,0.0005,27.6,0.0588,0.003,0.011,467,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-27",5,5,,,0,0.0006,25.1,0.0588,0.002,0.0106,425,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-28",6,6,,,0,0.0005,24.7,0.0582,0.002,0.0108,420,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-29",6,6,,,0,0.0005,24.1,0.059,0.002,0.0112,409,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-11-30",6,6,,,0,0.0007,39.3,0.0592,0.004,0.0115,666,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-01",5,5,,,0,0.0006,24.2,0.0598,0.002,0.0106,410,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-02",16,16,,,0,0.0003,60.8,0.0592,0.006,0.0107,1029,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-03",18,18,,,0,0.0003,64.2,0.0589,0.006,0.0111,1089,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-04",13,13,,,0,0.0002,48.2,0.0593,0.004,0.0108,814,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-05",14,14,,,0,0.0001,40,0.0589,0.004,0.0111,679,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-06",20,20,,,0,0.0001,61.5,0.0592,0.006,0.0111,1042,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-07",24,24,,,0,0.0001,79,0.059,0.007,0.0105,1337,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-08",23,23,,,0,0.0001,76.3,0.0587,0.007,0.0103,1297,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-09",22,22,,,0,0,78.3,0.0587,0.007,0.0104,1332,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-10",19,19,,,0,0.0003,70.9,0.0593,0.007,0.011,1201,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-11",24,24,,,0,0.0002,94.2,0.0588,0.009,0.0106,1600,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-12",23,23,,,0,0.0001,74.9,0.0588,0.007,0.0106,1272,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-13",10,10,,,0,0.0004,45.9,0.0587,0.004,0.0106,782,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-19",15,15,,,0,0.0002,65.9,0.0589,0.006,0.0107,1119,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-20",18,18,,,0,0.0001,59.3,0.0587,0.005,0.0104,1006,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-21",18,18,,,0,0.0001,57.5,0.0583,0.005,0.0104,982,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-22",19,19,,,0,0.0002,76.4,0.0587,0.007,0.0104,1295,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-23",20,20,,,0,0.0002,76,0.0587,0.007,0.0107,1289,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-24",11,11,,,0,0,29.8,0.0595,0.003,0.0108,502,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-25",7,7,,,0,0.0006,49.7,0.0589,0.005,0.0111,843,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-26",8,8,,,0,0.0005,35.3,0.0586,0.003,0.0113,599,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-27",5,5,,,0,0.0004,20.4,0.0592,0.002,0.011,344,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-28",8,8,,,0,0.0005,37.4,0.0591,0.003,0.0108,633,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-29",24,24,,,0,0.0003,96.9,0.0586,0.009,0.0105,1649,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-30",18,18,,,0,0.0001,59.1,0.0589,0.005,0.0107,1002,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 1",57074,"BLR1",,"2020-12-31",7,7,,,0,0.0007,50.8,0.0591,0.005,0.0113,858,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-01",12,12,,,0,0.0007,64.9,0.0589,0.006,0.0112,1098.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-02",10,10,,,0,0.0007,53.9,0.0592,0.005,0.0112,913.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-03",12,12,,,0,0.0003,91.1,0.059,0.009,0.0112,1544.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-04",13,13,,,0.001,0.0002,142.9,0.0591,0.013,0.0109,2420.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-05",13,13,,,0.001,0.0004,120.6,0.059,0.011,0.0111,2042.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-06",7,7,,,0,0.0007,48.3,0.0589,0.005,0.0109,820,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-07",11,11,,,0,0.0005,71,0.0591,0.007,0.0112,1203,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-08",6,6,,,0,0.0005,30.1,0.0593,0.003,0.0108,507.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-09",8,8,,,0,0.0006,55.6,0.0595,0.005,0.0105,941.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-28",4,4,,,0,0,7.6,0.0598,0.001,0.0115,128.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-29",9,9,,,0,0.0008,60.6,0.0588,0.006,0.0111,1026.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-30",10,10,,,0,0.0004,69.6,0.0586,0.006,0.0109,1179.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-01-31",7,7,,,0,0.0003,34.5,0.0589,0.003,0.0111,584.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-01",6,6,,,0,0.0005,29.7,0.0588,0.003,0.0108,504.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-02",13,13,,,0.001,0.0005,114.4,0.0591,0.011,0.011,1940,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-03",6,6,,,0,0.0008,43.2,0.059,0.004,0.0108,733.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-04",6,6,,,0,0.0005,34.9,0.059,0.003,0.0103,590.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-05",12,12,,,0,0.0003,100.3,0.0591,0.009,0.011,1698.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-06",5,5,,,0,0.0006,29.5,0.059,0.003,0.0108,498.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-07",4,4,,,0,0.0005,16.8,0.059,0.002,0.0103,285.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-08",5,5,,,0,0.0006,23.2,0.0588,0.002,0.011,392,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-09",8,8,,,0,0.0003,33.5,0.0589,0.003,0.0113,567.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-10",11,11,,,0,0.0005,69.8,0.059,0.007,0.011,1183,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-11",7,7,,,0,0.0004,37.8,0.059,0.004,0.0106,640.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-12",6,6,,,0,0.0002,52.6,0.0588,0.005,0.011,890.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-13",5,5,,,0,0.0004,23.7,0.059,0.002,0.011,403.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-14",7,7,,,0,0.0006,48,0.059,0.005,0.0111,814.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-15",12,12,,,0,0.0003,91.4,0.059,0.009,0.0108,1552.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-16",11,11,,,0,0.0008,77.9,0.0588,0.007,0.011,1319.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-17",11,11,,,0,0.0004,58.9,0.0591,0.006,0.0109,998.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-18",15,15,,,0.001,0.0005,133.8,0.0591,0.013,0.0111,2270.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-19",5,5,,,0,0.0006,25.7,0.059,0.002,0.0112,435.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-20",5,5,,,0,0.0004,20.7,0.0594,0.002,0.0114,348.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-21",7,7,,,0,0.0004,29.1,0.0589,0.003,0.0111,493.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-22",6,6,,,0,0.0007,29.6,0.0597,0.003,0.0113,501.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-23",6,6,,,0,0.0007,35.5,0.0587,0.003,0.011,602.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-24",5,5,,,0,0.0006,34.2,0.0588,0.003,0.011,580.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-25",5,5,,,0,0.0006,24.9,0.0598,0.002,0.0118,422.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-26",5,5,,,0,0.0002,17.5,0.0602,0.002,0.0116,295.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-27",6,6,,,0,0.0007,35.1,0.059,0.003,0.0113,594.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-28",12,12,,,0.001,0.0005,108.2,0.0589,0.01,0.011,1837.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-02-29",6,6,,,0,0.0005,25.7,0.0593,0.002,0.0108,434.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-01",9,9,,,0,0.0004,66.6,0.0589,0.006,0.0109,1130.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-02",6,6,,,0,0.0003,22,0.0588,0.002,0.0115,372.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-03",5,5,,,0,0.0004,21.7,0.0592,0.002,0.0112,367.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-04",6,6,,,0,0.0005,25.4,0.0587,0.002,0.0117,430.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-05",15,15,,,0.001,0.0006,97.1,0.0593,0.009,0.0112,1642.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-06",15,15,,,0.001,0.0007,113.9,0.059,0.011,0.011,1931.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-07",21,21,,,0,0.0004,109.4,0.0587,0.01,0.0107,1860.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-08",19,19,,,0,0.0003,101.5,0.0586,0.009,0.0107,1725.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-09",24,24,,,0,0.0001,129.6,0.059,0.012,0.011,2194.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-10",24,24,,,0,0,67.1,0.0583,0.006,0.0103,1151.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-11",24,24,,,0,0.0001,87.2,0.0585,0.008,0.0106,1488.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-12",24,24,,,0,0.0001,88.9,0.0584,0.008,0.0105,1516.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-13",24,24,,,0,0.0002,80.5,0.0586,0.007,0.0106,1373,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-14",24,24,,,0.001,0.0002,171.2,0.0588,0.016,0.0109,2904.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-15",24,24,,,0.001,0.0006,133,0.0589,0.012,0.011,2255.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-16",24,24,,,0.001,0.0005,173,0.0589,0.016,0.0109,2934.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-17",21,21,,,0.001,0.0006,148.8,0.059,0.014,0.0111,2523.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-18",6,6,,,0,0.0005,27.1,0.0585,0.003,0.0113,461.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-19",7,7,,,0,0.0006,40.8,0.0594,0.004,0.0117,689.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-20",10,10,,,0,0.0003,84.9,0.0589,0.008,0.0111,1438.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-21",9,9,,,0,0.0004,71,0.059,0.007,0.0113,1200.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-22",8,8,,,0,0.0006,38.6,0.059,0.004,0.0111,652.6,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-23",7,7,,,0,0.0009,51.2,0.059,0.005,0.0109,867.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-24",6,6,,,0,0.0003,34.6,0.059,0.003,0.011,585.3,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-25",7,7,,,0,0.0006,46.2,0.0587,0.004,0.0109,784.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-26",5,5,,,0,0.0006,30,0.059,0.003,0.0108,507.7,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-27",16,16,,,0.001,0.0008,99.4,0.0588,0.009,0.011,1685,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-28",14,14,,,0.001,0.0004,114.8,0.0593,0.011,0.0108,1944.4,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-29",10,10,,,0,0.0006,55.3,0.059,0.005,0.011,936.9,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-30",11,11,,,0,0.0004,69.7,0.059,0.006,0.0109,1181.8,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-03-31",16,16,,,0.001,0.0002,175.2,0.059,0.016,0.0111,2972.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-01",6,6,,,0,0.0007,32.5,0.059,0.003,0.0107,551,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-02",6,6,,,0,0.0005,32,0.0587,0.003,0.0113,542,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-03",10,10,,,0,0.0004,42,0.0589,0.004,0.0114,712,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-04",6,6,,,0,0.0007,28.6,0.0592,0.003,0.011,483,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-05",16,16,,,0.001,0.0008,93.5,0.0592,0.009,0.011,1582,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-06",7,7,,,0,0.0003,26.8,0.0591,0.003,0.0117,452,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-07",8,8,,,0,0.0005,51.8,0.059,0.005,0.0114,878,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-08",3,3,,,0,0,8.4,0.0593,0.001,0.0113,141,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-09",4,4,,,0,0.0003,15.5,0.0593,0.001,0.0108,262,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-10",7,7,,,0,0.0004,31.3,0.0591,0.003,0.0113,531,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-11",16,16,,,0.001,0.0008,117.5,0.0589,0.011,0.011,1992,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-12",15,15,,,0,0.0003,104.5,0.0591,0.01,0.011,1771,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-13",14,14,,,0,0.0004,96.5,0.0591,0.009,0.0112,1636,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-14",13,13,,,0,0.0003,87.6,0.0594,0.008,0.0112,1487,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-18",9,9,,,0,0,19.9,0.0594,0.002,0.0107,334,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-19",18,18,,,0,0.0003,81.3,0.0592,0.008,0.0111,1376,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-20",10,10,,,0,0.0004,40.3,0.0596,0.004,0.0112,680,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-21",8,8,,,0,0.0004,39.9,0.0588,0.004,0.011,676,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-22",12,12,,,0,0.0004,47.9,0.059,0.004,0.0104,812,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-23",14,14,,,0,0.0003,70.1,0.0592,0.007,0.0112,1189,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-24",14,14,,,0,0.0002,72.2,0.0596,0.007,0.0112,1221,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-25",13,13,,,0,0.0004,78.9,0.0589,0.007,0.0113,1336,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-26",14,14,,,0,0.0002,120,0.0592,0.011,0.0109,2033,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-27",10,10,,,0,0.0003,39.1,0.0588,0.004,0.0109,662,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-28",6,6,,,0,0.0003,26.5,0.0588,0.002,0.0108,449,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-29",11,11,,,0,0.0003,43,0.0589,0.004,0.0108,727,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-04-30",17,17,,,0,0.0002,84.3,0.0591,0.008,0.0106,1427,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-01",10,10,,,0,0.0005,53.8,0.0589,0.005,0.0111,911,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-02",15,15,,,0,0.0002,89.9,0.0587,0.008,0.0113,1527,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-03",18,18,,,0.001,0.0004,151.9,0.0589,0.014,0.0112,2577,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-04",13,13,,,0,0.0005,82.6,0.0592,0.008,0.011,1399,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-05",13,13,,,0,0.0005,75.5,0.0588,0.007,0.0108,1279,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-06",14,14,,,0,0.0006,86.5,0.0592,0.008,0.011,1467,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-07",16,16,,,0.001,0.0006,116.5,0.0591,0.011,0.0111,1975,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-08",17,17,,,0,0.0003,93.2,0.059,0.009,0.011,1579,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-13",13,13,,,0,0.0004,75.8,0.0591,0.007,0.0109,1286,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-14",17,17,,,0.001,0.0006,141.6,0.059,0.013,0.0111,2400,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-15",13,13,,,0,0.0004,87.3,0.0592,0.008,0.011,1479,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-16",14,14,,,0.001,0.0007,103.9,0.0589,0.01,0.0109,1762,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-17",15,15,,,0.001,0.0007,137.8,0.0591,0.013,0.011,2334,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-18",15,15,,,0.001,0.0004,110.6,0.0591,0.01,0.0111,1874,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-19",15,15,,,0.001,0.0006,96.4,0.0591,0.009,0.0109,1636,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-20",16,16,,,0.001,0.0005,108,0.0591,0.01,0.011,1828,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-21",14,14,,,0,0.0006,86.8,0.0593,0.008,0.011,1466,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-22",15,15,,,0,0.0005,87.4,0.059,0.008,0.0108,1481,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-23",17,17,,,0.001,0.0005,111.5,0.0591,0.01,0.011,1890,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-24",12,12,,,0,0.0005,80.8,0.0588,0.008,0.0109,1372,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-25",13,13,,,0,0.0005,82,0.0593,0.008,0.0108,1385,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-26",13,13,,,0,0.0004,78.5,0.0588,0.007,0.0111,1332,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-27",13,13,,,0,0.0005,85.3,0.059,0.008,0.0111,1443,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-28",14,14,,,0,0.0004,69.7,0.0593,0.007,0.0113,1178,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-29",9,9,,,0,0.0002,39.1,0.0594,0.004,0.0107,661,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-30",11,11,,,0,0.0004,59.7,0.0592,0.006,0.0112,1010,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-05-31",13,13,,,0,0.0006,66.1,0.0588,0.006,0.0108,1123,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-01",14,14,,,0.001,0.0006,120.1,0.0589,0.011,0.0109,2038,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-02",15,15,,,0.001,0.0005,127.3,0.0592,0.012,0.0111,2158,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-03",14,14,,,0.001,0.0006,95,0.0589,0.009,0.011,1611,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-04",10,10,,,0,0.0004,59.8,0.0592,0.006,0.0108,1013,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-05",17,17,,,0,0.0005,96.9,0.0588,0.009,0.0111,1641,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-06",18,18,,,0.001,0.0006,158.4,0.059,0.015,0.0109,2687,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-07",12,12,,,0,0.0004,71.1,0.059,0.007,0.0109,1207,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-08",14,14,,,0,0.0006,87.9,0.0586,0.008,0.0109,1489,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-09",14,14,,,0.001,0.0006,97.7,0.059,0.009,0.0109,1658,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-10",14,14,,,0,0.0004,95.5,0.0593,0.009,0.0108,1618,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-11",15,15,,,0,0.0004,100.7,0.0591,0.009,0.0112,1707,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-12",16,16,,,0.001,0.0008,153.4,0.059,0.014,0.0111,2597,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-13",18,18,,,0.001,0.0004,120.6,0.0591,0.011,0.011,2041,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-14",11,11,,,0,0.0005,75.1,0.059,0.007,0.0108,1275,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-15",13,13,,,0,0.0005,94.9,0.0589,0.009,0.011,1607,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-16",14,14,,,0.001,0.0005,108.5,0.059,0.01,0.0109,1837,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-17",13,13,,,0,0.0005,89.9,0.0589,0.008,0.0111,1526,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-18",18,18,,,0.001,0.0003,119.7,0.0591,0.011,0.011,2023,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-19",15,15,,,0.001,0.0004,104.3,0.059,0.01,0.0111,1768,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-20",15,15,,,0.001,0.0005,112.4,0.0593,0.011,0.0112,1903,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-21",12,12,,,0,0.0006,87.8,0.0588,0.008,0.011,1491,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-22",14,14,,,0,0.0005,98.7,0.059,0.009,0.0109,1673,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-23",18,18,,,0.001,0.0004,127.1,0.0588,0.012,0.0109,2156,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-24",12,12,,,0.001,0.0005,106.1,0.059,0.01,0.011,1796,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-25",11,11,,,0,0.0003,63.1,0.0593,0.006,0.0108,1068,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-26",9,9,,,0,0.0003,57.7,0.0588,0.005,0.0111,981,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-27",14,14,,,0.001,0.0005,113.4,0.059,0.01,0.0109,1920,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-28",8,8,,,0,0.0006,74.5,0.059,0.007,0.011,1262,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-29",12,12,,,0.001,0.0007,105.6,0.0591,0.01,0.0111,1791,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-01",7,7,,,0,0,14.7,0.0594,0.001,0.0113,248,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-02",16,16,,,0.001,0.0004,103.3,0.0591,0.01,0.0111,1751,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-03",18,18,,,0.001,0.0004,143.9,0.0591,0.013,0.0111,2435,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-04",17,17,,,0.001,0.0006,156.6,0.0588,0.015,0.011,2655,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-05",16,16,,,0.001,0.0006,122.2,0.0589,0.011,0.0109,2072,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-06",15,15,,,0.001,0.0004,114,0.0591,0.011,0.0111,1933,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-07",23,23,,,0.001,0.0008,197.7,0.0591,0.018,0.011,3350,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-08",14,14,,,0,0.0002,81.3,0.059,0.008,0.011,1375,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-09",13,13,,,0,0.0004,95.7,0.0588,0.009,0.0109,1621,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-10",13,13,,,0.001,0.0006,98.3,0.0589,0.009,0.0111,1666,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-11",16,16,,,0.001,0.0007,120.9,0.0591,0.011,0.0109,2048,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-12",8,8,,,0,0.0006,47.3,0.059,0.004,0.0105,801,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-13",13,13,,,0.001,0.0006,101.9,0.0588,0.01,0.0112,1728,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-14",14,14,,,0.001,0.0007,85.6,0.0591,0.008,0.0106,1450,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-15",4,4,,,0,0.0003,18.9,0.059,0.002,0.0115,321,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-16",3,3,,,0,0,4.6,0.0593,0,0.0123,77,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-17",12,12,,,0,0.0003,51.3,0.0594,0.005,0.0111,869,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-18",18,18,,,0,0.0003,76,0.0592,0.007,0.0113,1289,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-19",24,24,,,0.001,0.0004,122.3,0.0593,0.011,0.0108,2070,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-20",15,15,,,0,0.0006,79.8,0.0594,0.007,0.011,1349,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-21",14,14,,,0.001,0.0007,114.4,0.0587,0.011,0.0108,1937,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-22",18,18,,,0.001,0.0005,126.5,0.0586,0.012,0.0111,2141,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-23",15,15,,,0.001,0.0004,112.5,0.0593,0.011,0.0113,1904,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-24",17,17,,,0.001,0.0006,109.3,0.0591,0.01,0.011,1852,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-25",15,15,,,0.001,0.0005,111.5,0.0591,0.01,0.0111,1889,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-26",15,15,,,0.001,0.0005,130.2,0.0591,0.012,0.0111,2206,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-27",17,17,,,0.001,0.0008,160.6,0.0591,0.015,0.011,2721,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-28",8,8,,,0,0.0005,53.4,0.0594,0.005,0.0113,908,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-29",9,9,,,0,0.0006,53.8,0.0588,0.005,0.0108,913,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-30",4,4,,,0,0.0005,19,0.0593,0.002,0.011,321,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-07-31",10,10,,,0,0.0005,57.4,0.059,0.005,0.0109,973,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-01",9,9,,,0,0.0006,58.7,0.0593,0.006,0.0113,992,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-02",12,12,,,0,0.0007,83.3,0.0589,0.008,0.0112,1412,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-03",17,17,,,0.001,0.0005,160.4,0.0591,0.015,0.011,2714,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-04",18,18,,,0.001,0.0002,169.6,0.0591,0.016,0.0111,2872,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-05",18,18,,,0.001,0.0004,126.1,0.0589,0.012,0.0109,2138,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-06",14,14,,,0.001,0.0007,114,0.0591,0.011,0.011,1933,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-07",14,14,,,0.001,0.0005,112.3,0.0589,0.01,0.0111,1905,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-08",15,15,,,0.001,0.0005,109.4,0.0589,0.01,0.0112,1854,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-09",14,14,,,0.001,0.0005,99.8,0.059,0.009,0.0114,1692,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-10",12,12,,,0,0.0006,85.9,0.059,0.008,0.0109,1457,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-11",17,17,,,0,0.0003,113.9,0.059,0.011,0.0108,1931,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-12",9,9,,,0,0.0003,51.6,0.0593,0.005,0.011,872,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-13",15,15,,,0.001,0.0005,124.6,0.0591,0.012,0.0111,2111,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-14",18,18,,,0.001,0.0006,129.3,0.0588,0.012,0.0111,2193,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-15",9,9,,,0,0.0006,59.4,0.059,0.006,0.0111,1005,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-16",16,16,,,0.001,0.0009,144.3,0.0589,0.013,0.0109,2449,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-17",15,15,,,0.001,0.0007,110.3,0.0591,0.01,0.0108,1871,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-18",14,14,,,0.001,0.0008,131.7,0.059,0.012,0.0111,2235,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-19",14,14,,,0.001,0.0008,138.7,0.0591,0.013,0.011,2350,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-20",19,19,,,0.001,0.0006,185.3,0.0589,0.017,0.0111,3138,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-21",19,19,,,0.001,0.0008,174.6,0.0588,0.016,0.0111,2959,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-22",14,14,,,0.001,0.0007,98.2,0.0587,0.009,0.0114,1664,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-23",15,15,,,0.001,0.0007,127.1,0.0591,0.012,0.011,2156,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-24",14,14,,,0.001,0.0007,116.9,0.0592,0.011,0.0111,1980,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-25",18,18,,,0.001,0.0008,152.2,0.0591,0.014,0.011,2579,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-26",16,16,,,0.001,0.0009,141.2,0.0591,0.013,0.011,2395,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-27",17,17,,,0.001,0.0006,156,0.0591,0.014,0.0109,2639,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-28",15,15,,,0.001,0.0007,114.9,0.059,0.011,0.0109,1944,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-29",16,16,,,0.001,0.0004,152.9,0.059,0.014,0.011,2593,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-30",16,16,,,0.001,0.0008,98.7,0.0589,0.009,0.0109,1676,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-08-31",12,12,,,0,0.0008,90.3,0.0588,0.009,0.0111,1533,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-01",16,16,,,0.001,0.0004,158.8,0.0589,0.015,0.0109,2694,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-02",14,14,,,0,0.0005,102,0.059,0.01,0.0107,1731,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-03",13,13,,,0.001,0.0005,95.7,0.0592,0.009,0.011,1622,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-04",13,13,,,0,0.0005,82.6,0.0588,0.008,0.0109,1402,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-05",16,16,,,0.001,0.0006,126.7,0.0591,0.012,0.0111,2145,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-06",15,15,,,0,0.0004,94.1,0.0588,0.009,0.0112,1595,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-07",14,14,,,0.001,0.0002,138,0.0591,0.013,0.0111,2340,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-08",18,18,,,0.001,0.0004,184.4,0.0591,0.017,0.0109,3124,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-09",14,14,,,0.001,0.0004,108.5,0.0591,0.01,0.0109,1838,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-10",13,13,,,0,0.0004,96,0.059,0.009,0.0111,1627,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-11",14,14,,,0.001,0.0004,97.7,0.059,0.009,0.011,1659,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-12",16,16,,,0.001,0.0003,152.2,0.0589,0.014,0.0109,2581,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-13",13,13,,,0.001,0.0005,102.1,0.0592,0.01,0.011,1727,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-14",16,16,,,0.001,0.0002,151.2,0.0591,0.014,0.0111,2563,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-15",12,12,,,0.001,0.0003,106.9,0.059,0.01,0.0111,1811,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-16",17,17,,,0.001,0.0002,156.6,0.0589,0.015,0.011,2654,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-17",16,16,,,0.001,0.0004,152.4,0.0591,0.014,0.011,2581,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-18",15,15,,,0.001,0.0005,121.5,0.0591,0.011,0.011,2056,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-19",17,17,,,0.001,0.0004,156.5,0.0591,0.015,0.0109,2649,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-20",17,17,,,0.001,0.0005,142,0.059,0.013,0.0109,2408,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-21",17,17,,,0.001,0.0004,155.2,0.0587,0.015,0.0111,2629,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-22",17,17,,,0.001,0.0005,147.6,0.0588,0.014,0.011,2504,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-23",16,16,,,0.001,0.0006,116.3,0.059,0.011,0.0109,1972,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-24",16,16,,,0.001,0.0006,127.8,0.0588,0.012,0.0113,2167,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-25",16,16,,,0.001,0.0004,143.5,0.0588,0.013,0.0111,2431,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-26",17,17,,,0.001,0.0006,136.9,0.059,0.013,0.0108,2320,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-27",16,16,,,0.001,0.0004,155.2,0.0589,0.015,0.0111,2632,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-28",15,15,,,0.001,0.0006,103.1,0.0591,0.01,0.0108,1752,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-29",15,15,,,0.001,0.0005,98.7,0.0594,0.009,0.0113,1670,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-09-30",17,17,,,0.001,0.0004,109.3,0.0589,0.01,0.0111,1853,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-01",15,15,,,0,0.0005,87,0.0589,0.008,0.0109,1479,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-02",13,13,,,0,0.0004,80.1,0.0588,0.007,0.0104,1357,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-03",12,12,,,0,0.0005,88.2,0.059,0.008,0.0111,1496,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-04",12,12,,,0,0.0005,82.8,0.0591,0.008,0.011,1404,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-05",15,15,,,0.001,0.0005,114.4,0.0589,0.011,0.0109,1940,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-06",15,15,,,0,0.0004,100.9,0.0589,0.009,0.0109,1712,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-07",16,16,,,0.001,0.0005,110.9,0.0592,0.01,0.0109,1873,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-08",18,18,,,0,0.0004,90.8,0.0593,0.009,0.0115,1538,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-09",24,24,,,0,0.0004,103.1,0.0593,0.01,0.0115,1747,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-10",24,24,,,0.001,0.0003,143.3,0.059,0.013,0.0114,2432,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-11",17,17,,,0,0.0004,70.2,0.059,0.007,0.0115,1195,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-12",9,9,,,0,0.0003,40.6,0.0592,0.004,0.0114,688,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-13",6,6,,,0,0.0005,27.9,0.0588,0.003,0.0113,473,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-14",14,14,,,0,0.0004,99,0.0591,0.009,0.0109,1679,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-15",5,5,,,0,0.0006,26.9,0.0588,0.003,0.011,456,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-16",6,6,,,0,0.0007,30.8,0.0592,0.003,0.0112,523,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-17",9,9,,,0,0.0006,56.4,0.0587,0.005,0.0109,958,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-18",6,6,,,0,0.0007,31.8,0.0593,0.003,0.0113,538,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-19",7,7,,,0,0.0006,31,0.0591,0.003,0.011,526,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-20",16,16,,,0.001,0.0006,145.3,0.0589,0.014,0.0109,2462,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-21",7,7,,,0,0.0006,33.1,0.0589,0.003,0.011,562,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-22",7,7,,,0,0.0006,32,0.0589,0.003,0.0106,542,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-23",12,12,,,0,0.0003,73.3,0.0588,0.007,0.0108,1242,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-24",16,16,,,0.001,0.0005,98.3,0.059,0.009,0.0112,1665,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-25",5,5,,,0,0.0004,24.1,0.0592,0.002,0.0108,407,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-26",6,6,,,0,0.0005,28.4,0.0592,0.003,0.0115,482,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-27",5,5,,,0,0.0008,32.3,0.0592,0.003,0.011,546,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-28",5,5,,,0,0.0004,24.5,0.059,0.002,0.0112,416,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-29",4,4,,,0,0.0005,20.9,0.0588,0.002,0.0115,355,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-30",6,6,,,0,0.0007,29.1,0.059,0.003,0.011,494,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-10-31",6,6,,,0,0.0007,29.4,0.0593,0.003,0.0112,498,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-01",14,14,,,0.001,0.0004,119.1,0.059,0.011,0.0109,2021,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-02",6,6,,,0,0.0007,30.3,0.0587,0.003,0.0113,516,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-03",6,6,,,0,0.0005,30.4,0.0593,0.003,0.011,515,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-04",5,5,,,0,0.0006,26.1,0.0588,0.003,0.0112,444,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-05",5,5,,,0,0.0004,21.5,0.0586,0.002,0.0114,365,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-06",7,7,,,0,0.0006,30.2,0.0593,0.003,0.0109,511,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-07",22,22,,,0,0.0002,85.9,0.059,0.008,0.0117,1458,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-08",24,24,,,0,0.0003,89.1,0.0597,0.009,0.0116,1506,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-09",20,20,,,0,0.0002,63,0.0594,0.006,0.0118,1068,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-10",18,18,,,0,0.0001,56.1,0.0594,0.005,0.0118,948,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-11",19,19,,,0,0.0002,63.8,0.0593,0.006,0.0118,1080,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-12",17,17,,,0,0.0003,61.2,0.0596,0.006,0.0116,1035,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-13",18,18,,,0,0.0002,61.3,0.0593,0.006,0.0116,1039,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-14",18,18,,,0,0.0002,58.6,0.0595,0.006,0.0114,991,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-15",18,18,,,0,0.0002,59,0.0598,0.006,0.0116,994,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-16",18,18,,,0,0.0003,63.7,0.0596,0.006,0.0116,1075,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-17",24,24,,,0,0.0003,127.7,0.0594,0.012,0.0115,2160.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-18",21,21,,,0,0.0001,59.6,0.0596,0.006,0.0119,1007,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-19",21,21,,,0,0,59.4,0.0591,0.006,0.0117,1008,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-20",24,24,,,0,0.0003,103.9,0.0593,0.01,0.0116,1761,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-21",24,24,,,0.001,0.0004,133.3,0.0591,0.013,0.0113,2258.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-22",21,21,,,0,0.0002,82.8,0.0592,0.008,0.0114,1400,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-23",24,24,,,0,0.0002,102.8,0.0589,0.01,0.0112,1749.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-24",19,19,,,0,0.0002,68.2,0.0595,0.007,0.0117,1152,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-25",18,18,,,0,0.0002,61.5,0.0597,0.006,0.0118,1039,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-26",18,18,,,0,0.0002,58,0.0593,0.006,0.0117,983,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-27",18,18,,,0,0.0002,59.5,0.0589,0.006,0.0117,1010,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-28",18,18,,,0,0.0001,49.1,0.0591,0.005,0.0116,834,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-29",18,18,,,0,0.0002,60.2,0.0594,0.006,0.0114,1018,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-11-30",19,19,,,0,0.0003,70.3,0.0595,0.007,0.0117,1187,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-01",18,18,,,0,0.0002,62.9,0.0592,0.006,0.0113,1067,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-02",18,18,,,0,0.0002,52.2,0.0586,0.005,0.0117,884,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-03",13,13,,,0,0.0002,31.8,0.058,0.003,0.0122,540,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-04",7,7,,,0,0.0004,30.2,0.059,0.003,0.011,512,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-05",12,12,,,0,0.0001,27.3,0.0585,0.003,0.0115,465,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-06",17,17,,,0,0.0001,53.2,0.0596,0.005,0.0119,900,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-07",24,24,,,0.001,0.0003,119,0.0593,0.011,0.0115,2017.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-08",24,24,,,0,0.0002,146.6,0.0595,0.014,0.0115,2481.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-09",24,24,,,0,0.0002,116.5,0.0592,0.011,0.0116,1973,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-10",20,20,,,0.001,0.0003,156,0.0593,0.015,0.0113,2641.5,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-11",22,22,,,0,0.0003,80.1,0.0591,0.008,0.0113,1356,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-12",24,24,,,0,0.0003,113.8,0.0589,0.011,0.0113,1931,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-13",15,15,,,0,0.0004,108.8,0.0587,0.01,0.0113,1847.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-19",21,21,,,0,0.0001,84.9,0.0591,0.008,0.0115,1439,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-20",18,18,,,0,0.0001,54,0.0591,0.005,0.0119,918,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-21",18,18,,,0,0.0001,55.6,0.0595,0.005,0.0114,939,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-22",20,20,,,0,0.0002,68,0.0597,0.007,0.0117,1149,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-23",22,22,,,0,0.0001,101.8,0.0593,0.01,0.0113,1722.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-24",24,24,,,0,0,65.6,0.0593,0.006,0.0114,1111,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-25",24,24,,,0,0.0003,123.8,0.0593,0.012,0.0117,2096,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-26",24,24,,,0,0.0003,105.6,0.0594,0.01,0.0114,1789.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-27",24,24,,,0,0,60.5,0.0593,0.006,0.0119,1027,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-28",24,24,,,0,0,59.1,0.0592,0.006,0.0117,1003,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-29",24,24,,,0,0.0002,100.8,0.0593,0.01,0.0116,1706.1,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-30",23,23,,,0,0.0002,111.8,0.0595,0.011,0.0113,1890.2,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Ivanpah 3",57075,"BLR1",,"2020-12-31",24,24,,,0,0.0003,100.2,0.059,0.01,0.0115,1699,"Pipeline Natural Gas",,"Other boiler",,,,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-16",3,1.25,182.68,,0.001,0.001,122.678,0.059,0.017,0.0397,2064.842,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-19",6,4.34,826.86,,0.003,0.001,520.116,0.059,0.039,0.0182,8750.81,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-09",2,0.9,99.02,,0,0.001,72.774,0.059,0.01,0.015,1224.846,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-12",4,3.57,483.34,,0.002,0.001,329.99,0.059,0.024,0.0095,5551.77,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-13",1,1,119,,0,0.001,83.9,0.059,0.006,0.008,1412.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-21",3,2.43,455.24,,0.001,0.001,288.126,0.059,0.025,0.0117,4847.967,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-13",4,2.63,332.96,,0.001,0.001,233.012,0.059,0.019,0.0123,3921.356,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-16",2,1.32,148.2,,0.001,0.001,107.346,0.059,0.011,0.0115,1806.224,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-26",8,6.49,854.02,,0.003,0.001,590.884,0.059,0.04,0.012,9942.71,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-27",5,3.5,588.41,,0.002,0.001,384.059,0.059,0.026,0.0184,6461.982,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-03",3,2.43,434.2,,0.001,0.001,277.482,0.059,0.021,0.0097,4669.68,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-05",2,0.95,126.13,,0,0.001,86.193,0.059,0.01,0.013,1450.218,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-25",9,8.22,1277.78,,0.004,0.001,840.652,0.059,0.054,0.0102,14145.19,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-08",5,3.34,417.24,,0.001,0.001,290.272,0.059,0.022,0.0154,4883.023,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-27",11,9.85,1296.34,,0.004,0.001,886.467,0.059,0.057,0.0082,14914.119,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-30",6,5.12,635.6,,0.002,0.001,442.404,0.059,0.03,0.0172,7445.74,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-14",11,10.72,1842.92,,0.006,0.001,1186.624,0.059,0.073,0.0075,19965.584,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-15",17,15.49,2437.27,,0.008,0.001,1598.468,0.059,0.102,0.0094,26898.49,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-16",12,10.02,1601.4,,0.005,0.001,1049.326,0.0591,0.063,0.01,17657.498,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-17",14,13,2257.6,,0.007,0.001,1452.62,0.059,0.087,0.0089,24444.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-18",9,8.52,1341.96,,0.004,0.001,881.976,0.059,0.055,0.0076,14842.252,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-19",17,15.4,2283.76,,0.008,0.001,1516.82,0.059,0.092,0.0091,25525.508,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-26",4,2.25,376.91,,0.001,0.001,243.68,0.059,0.019,0.0268,4100.586,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-28",5,3.88,476.38,,0.002,0.001,333.256,0.059,0.023,0.0104,5608.645,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-30",6,2.47,391.87,,0.001,0.001,256.939,0.059,0.02,0.0262,4324.057,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-05",8,7.88,952.68,,0.003,0.001,671.404,0.059,0.043,0.0078,11300.164,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-06",6,5.14,903.12,,0.003,0.001,581.156,0.059,0.043,0.0092,9777.276,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-08",6,3.67,506.41,,0.002,0.001,344.511,0.059,0.032,0.0215,5795.402,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-09",17,15.97,2305.71,,0.008,0.001,1544.468,0.059,0.09,0.0091,25990.121,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-09-30",6,4.72,565.03,,0.002,0.001,400.355,0.059,0.028,0.0145,6736.925,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-01",5,4.29,754.7,,0.002,0.001,490.333,0.059,0.033,0.0086,8249.618,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-05",6,4.79,576.1,,0.002,0.001,406.714,0.059,0.029,0.0118,6841.086,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-16",4,3.04,554.14,,0.002,0.001,353.492,0.059,0.027,0.01,5947.533,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-17",9,5.54,927.15,,0.003,0.001,599.91,0.059,0.042,0.0197,10093.92,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-18",9,7.24,1279.52,,0.004,0.001,819.538,0.059,0.053,0.0152,13791.164,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-19",11,8.88,1556.11,,0.005,0.001,997.331,0.059,0.064,0.0095,16781.281,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-20",8,5.17,870.61,,0.003,0.001,564.958,0.059,0.039,0.0141,9505.987,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-05",8,7.1,930.4,,0.003,0.001,642.92,0.059,0.043,0.0081,10817.74,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-18",21,20.17,3548.37,,0.012,0.001,2282.994,0.059,0.157,0.0109,38416.481,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-19",1,0.03,1.23,,0,0.001,1.473,0.059,0.001,0.055,24.78,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-12",7,6.22,1220.59,,0.004,0.001,762.85,0.059,0.05,0.0087,12836.066,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-13",3,1.53,218.17,,0.001,0.001,148.16,0.059,0.015,0.0253,2493.174,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-10",3,1.53,203.63,,0.001,0.001,141.344,0.059,0.026,0.023,2378.256,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-09",1,0.9,98.1,,0,0.001,72.99,0.059,0.011,0.018,1227.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-12",4,2.59,356.38,,0.001,0.001,244.623,0.059,0.023,0.0173,4115.696,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-13",4,2.63,332.2,,0.001,0.001,233.996,0.059,0.022,0.0138,3938.485,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-18",6,4.25,628.35,,0.002,0.001,422.215,0.059,0.033,0.0193,7105.716,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-26",8,7,955.76,,0.003,0.001,657.356,0.059,0.049,0.0093,11061.064,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-27",9,8.72,1303.68,,0.004,0.001,876.56,0.059,0.06,0.0083,14753.724,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-28",7,5.19,806.54,,0.003,0.001,537.993,0.059,0.041,0.0119,9052.527,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-02",9,6.71,1158.87,,0.004,0.001,748.651,0.059,0.056,0.0112,12597.114,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-03",10,8.77,1580.93,,0.005,0.001,1011.502,0.059,0.071,0.0101,17020.19,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-04",6,5.72,721.84,,0.003,0.001,501.496,0.059,0.037,0.0088,8436.872,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-10",5,2.91,465.87,,0.002,0.001,307.148,0.059,0.027,0.0246,5168.639,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-17",1,0.08,0,,0,0.001,2.008,0.059,0.001,0.068,33.8,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-30",6,5.12,637,,0.002,0.001,445.032,0.059,0.033,0.0213,7486.892,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-13",6,5.12,615.8,,0.002,0.001,436.188,0.059,0.03,0.02,7338.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-14",14,13.22,2319.34,,0.008,0.001,1493.788,0.059,0.091,0.0086,25136.204,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-15",24,24,4330,,0.014,0.001,2767.9,0.059,0.165,0.0071,46575.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-16",14,12.38,2220.17,,0.007,0.001,1423.55,0.059,0.089,0.008,23951.734,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-17",24,23.65,4040.4,,0.013,0.001,2619.81,0.059,0.158,0.0072,44082.53,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-18",21,18.67,3134.48,,0.01,0.001,2039.077,0.059,0.128,0.008,34308.091,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-19",24,24,4276,,0.014,0.001,2736.8,0.059,0.163,0.0071,46049.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-20",1,0.03,1.17,,0,0.001,1.425,0.059,0.001,0.067,23.982,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-24",6,4.32,509.72,,0.002,0.001,361.962,0.059,0.029,0.015,6091.956,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-26",20,18.14,3229.35,,0.01,0.001,2061.667,0.059,0.134,0.0098,34692.287,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-27",24,24,4363,,0.014,0.001,2769.4,0.059,0.166,0.0071,46605.1,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-28",24,24,4366,,0.014,0.001,2777.4,0.059,0.17,0.0073,46734.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-29",14,11.28,2013.78,,0.006,0.001,1286.493,0.059,0.081,0.0161,21647.722,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-30",11,8.19,1472.15,,0.005,0.001,943.047,0.059,0.063,0.0156,15867.951,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-08-31",13,12.17,2263.18,,0.007,0.001,1435.427,0.059,0.087,0.01,24154.278,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-01",1,0.03,1.11,,0,0.001,1.386,0.059,0.001,0.069,23.319,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-02",11,9.2,1475.2,,0.005,0.001,968.945,0.059,0.064,0.0172,16302.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-03",12,10.19,1897.28,,0.006,0.001,1207.715,0.059,0.076,0.0132,20324.885,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-05",14,12.19,2214.34,,0.007,0.001,1425.11,0.059,0.095,0.0105,23982.352,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-06",24,22.96,4190.04,,0.014,0.001,2687.776,0.059,0.162,0.0074,45225.224,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-07",23,22.03,4123.38,,0.013,0.001,2626.906,0.059,0.158,0.0098,44204.141,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-08",13,10.02,1788.52,,0.006,0.001,1149.478,0.059,0.077,0.0111,19344.458,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-09",24,22.96,3898.6,,0.013,0.001,2527.136,0.059,0.155,0.0075,42521.004,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-10",1,0.03,0.84,,0,0.001,1.278,0.059,0.001,0.058,21.513,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-19",5,3.74,617.1,,0.002,0.001,405.66,0.059,0.032,0.0126,6825.18,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-29",6,4.54,545.72,,0.002,0.001,387.149,0.059,0.028,0.0128,6513.261,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-09-30",10,8.23,1519.11,,0.005,0.001,973.111,0.059,0.064,0.0156,16376.143,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-01",9,7.53,1383.06,,0.005,0.001,892.825,0.059,0.059,0.0128,15023.826,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-05",6,4.77,573.2,,0.002,0.001,407.283,0.059,0.03,0.0127,6852.526,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-16",4,2.75,500.5,,0.002,0.001,321.205,0.059,0.027,0.0135,5405.71,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-17",14,13.15,2488.4,,0.008,0.001,1577.27,0.059,0.099,0.0129,26544.85,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-18",11,8.32,1541.33,,0.005,0.001,984.962,0.059,0.064,0.0164,16574.622,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-19",12,10.35,1904.05,,0.006,0.001,1215.19,0.059,0.082,0.013,20447.91,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-20",10,8.38,1537.92,,0.005,0.001,985.684,0.059,0.064,0.0116,16587.064,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-26",6,4.52,835.02,,0.003,0.001,531.108,0.059,0.041,0.0173,8935.724,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-05",8,7.33,1029.6,,0.004,0.001,701.617,0.059,0.049,0.0085,11806.712,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-17",17,16.23,2963.43,,0.01,0.001,1899.203,0.059,0.147,0.0098,31955.232,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-18",4,2.1,373.39,,0.001,0.001,242.698,0.059,0.024,0.0158,4084.009,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-13",3,2.02,278.2,,0.001,0.001,191.464,0.059,0.019,0.0267,3221.954,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-15",4,3.27,619.22,,0.002,0.001,393.187,0.059,0.034,0.0115,6615.262,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-16",7,6.34,988.12,,0.003,0.001,653.234,0.059,0.05,0.0094,10991.85,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-16",2,0.85,97.33,,0,0.001,68.779,0.059,0.01,0.0195,1156.856,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-17",2,0.91,101.14,,0,0.001,73.431,0.059,0.01,0.0155,1235.68,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-13",4,2.65,358.06,,0.001,0.001,243.333,0.059,0.022,0.014,4094.104,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-17",2,1.63,240.43,,0.001,0.001,159.25,0.059,0.024,0.02,2679.306,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-18",22,19.26,2982.06,,0.01,0.001,1922.378,0.059,0.128,0.0111,32345.326,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-26",7,6.22,825.8,,0.003,0.001,557.686,0.059,0.04,0.0116,9381.534,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-27",6,6,824,,0.003,0.001,499.1,0.059,0.034,0.008,8401.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-03",3,1.68,287.71,,0.001,0.001,184.273,0.059,0.016,0.033,3101.481,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-07",1,0.07,0,,0,0.001,1.491,0.06,0,0.028,25.032,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-17",8,6.4,772.24,,0.003,0.001,541.611,0.059,0.037,0.0165,9114.558,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-27",2,1.53,213.44,,0.001,0.001,145.094,0.059,0.015,0.0135,2441.176,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-30",8,7.12,890.72,,0.003,0.001,616.908,0.059,0.045,0.0171,10380.972,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-07-31",5,4.27,529.43,,0.002,0.001,366.957,0.059,0.026,0.009,6176.086,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-03",11,10.75,1324.5,,0.005,0.001,923.975,0.059,0.063,0.0083,15545.375,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-04",3,2.5,304,,0.001,0.001,212.75,0.059,0.015,0.0083,3579.2,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-13",8,7.7,937.3,,0.003,0.001,655.55,0.059,0.048,0.0091,11030.95,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-14",24,24,3550,,0.012,0.001,2360.1,0.059,0.153,0.0077,39712.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-15",24,24,3613,,0.012,0.001,2392.8,0.059,0.155,0.0077,40263.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-16",17,15.77,2390.25,,0.008,0.001,1585.785,0.059,0.108,0.0106,26685.642,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-17",14,13,2247.4,,0.007,0.001,1448.5,0.059,0.093,0.0089,24373.96,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-18",12,10.9,1901.2,,0.006,0.001,1222.11,0.0591,0.079,0.0111,20565.61,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-19",17,15.44,2221.4,,0.007,0.001,1485.154,0.059,0.101,0.0096,24994.914,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-24",7,6.72,817.92,,0.003,0.001,571.06,0.059,0.042,0.0091,9607.5,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-25",7,6.25,765.75,,0.003,0.001,532.275,0.059,0.036,0.0086,8956.025,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-26",13,10.47,1419.67,,0.005,0.001,961.477,0.059,0.07,0.0149,16178.178,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-27",18,16.11,2348.66,,0.008,0.001,1554.388,0.059,0.104,0.0123,26159.786,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-28",10,7.47,935.65,,0.003,0.001,649.052,0.059,0.048,0.0151,10919.646,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-01",6,5.27,635.57,,0.002,0.001,445.905,0.059,0.036,0.0138,7502.902,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-05",10,8.82,1527.2,,0.005,0.001,987.474,0.059,0.069,0.0114,16616.358,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-06",6,5.46,971.3,,0.003,0.001,624.34,0.059,0.044,0.0087,10506.274,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-07",3,1.25,197.95,,0.001,0.001,131.429,0.059,0.011,0.0237,2211.713,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-08",15,12.94,1669.13,,0.006,0.001,1148.428,0.059,0.074,0.0099,19327.335,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-10",1,0.1,1.9,,0,0.001,3.52,0.059,0.003,0.091,59.18,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-11",4,3.27,396.62,,0.001,0.001,280.322,0.059,0.02,0.0093,4717.467,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-29",7,5.54,667.71,,0.002,0.001,470.222,0.059,0.033,0.0123,7912.961,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-09-30",7,5.74,964.58,,0.003,0.001,627.555,0.059,0.041,0.0141,10561.692,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-01",4,2.98,499.42,,0.002,0.001,328.186,0.059,0.025,0.0113,5521.82,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-05",8,7.68,934.44,,0.003,0.001,657.096,0.059,0.043,0.0083,11056.756,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-06",4,3.07,373.76,,0.001,0.001,261.735,0.059,0.016,0.0133,4404.767,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-16",3,2.54,436.25,,0.001,0.001,282.468,0.059,0.024,0.0113,4753.508,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-17",12,9.24,1599.11,,0.005,0.001,1024.243,0.059,0.067,0.0153,17233.923,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-18",8,5.82,999.12,,0.003,0.001,644.899,0.059,0.044,0.0134,10851.567,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-19",11,9.32,1580.45,,0.005,0.001,1019.967,0.059,0.064,0.0115,17163.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-20",8,5.17,862.58,,0.003,0.001,561.277,0.059,0.039,0.0134,9445.058,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-19",20,19.13,3384.24,,0.011,0.001,2172.555,0.059,0.158,0.0144,36556.252,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-20",1,0.07,5.18,,0,0.001,4.459,0.059,0.001,0.032,75.061,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-13",12,11.2,1412.4,,0.005,0.001,984.52,0.059,0.058,0.0122,16564.64,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-14",1,0.02,0.52,,0,0.001,0.836,0.059,0,0.04,14.08,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-03",2,0.87,92.54,,0,0.001,68.329,0.059,0.011,0.022,1149.368,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-04",1,0.87,93.96,,0,0.001,69.252,0.059,0.012,0.021,1165.452,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-08",8,7.3,1235.04,,0.004,0.001,791.66,0.059,0.089,0.0133,13322.624,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-16",3,1.27,195.22,,0.001,0.001,128.863,0.059,0.02,0.041,2167.723,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-19",4,1.47,179.46,,0.001,0.001,126.443,0.059,0.022,0.0368,2128.38,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-16",2,0.99,110.58,,0,0.0005,79.972,0.059,0.009,0.007,1345.918,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-13",4,2.63,332.07,,0.001,0.001,231.513,0.059,0.019,0.012,3895.111,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-18",6,5.22,808.16,,0.003,0.001,529.222,0.059,0.035,0.0122,8905.088,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-19",5,3.24,513.38,,0.002,0.001,335.32,0.059,0.025,0.0206,5642.416,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-26",9,8.72,1283.2,,0.004,0.001,852.12,0.059,0.052,0.0073,14338.46,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-27",12,9.26,1304.66,,0.004,0.001,871.656,0.059,0.053,0.0146,14668.876,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-28",9,7.23,1318.23,,0.004,0.001,836.891,0.059,0.051,0.0147,14080.985,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-02",9,7.32,1298.58,,0.004,0.001,823.408,0.059,0.051,0.013,13854.006,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-03",10,8.24,1387.46,,0.004,0.001,888.716,0.059,0.053,0.0113,14956.748,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-17",4,3.12,384.92,,0.001,0.001,267.696,0.059,0.02,0.0238,4503.948,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-27",11,9.84,1249.96,,0.004,0.001,858.036,0.059,0.056,0.0085,14438.012,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-30",6,5.12,638.36,,0.002,0.001,441.152,0.059,0.03,0.0188,7421.892,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-03",11,10.75,1324.5,,0.005,0.001,919.9,0.059,0.057,0.0075,15474.75,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-04",3,2.5,304.5,,0.001,0.001,211.9,0.059,0.013,0.0073,3565.45,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-13",8,7.12,865.8,,0.003,0.001,603.58,0.059,0.039,0.0191,10156.112,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-14",24,24,3611,,0.012,0.001,2377.3,0.059,0.136,0.0068,40005.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-15",24,24,4241,,0.014,0.001,2691.9,0.059,0.152,0.0067,45294.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-16",24,24,4286,,0.014,0.001,2720.2,0.059,0.157,0.0069,45775,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-17",15,13.23,2173.1,,0.007,0.001,1407.576,0.059,0.081,0.0122,23685.485,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-18",24,24,3885,,0.013,0.001,2519.6,0.059,0.142,0.0067,42396.4,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-19",24,24,4313,,0.014,0.001,2727.1,0.059,0.156,0.0068,45884.3,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-20",24,24,4286,,0.014,0.001,2710.7,0.059,0.155,0.0068,45615,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-21",1,0.02,0.28,,0,0.001,0.704,0.059,0,0.033,11.854,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-24",7,5.79,701.75,,0.002,0.001,489.453,0.059,0.032,0.0111,8235.296,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-25",2,1.12,188.64,,0.001,0.001,121.756,0.059,0.012,0.047,2049.224,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-26",23,22.03,4048.02,,0.013,0.001,2542.038,0.059,0.145,0.0094,42775.391,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-28",5,4.33,531.91,,0.002,0.001,370.436,0.059,0.027,0.011,6232.796,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-29",12,11.22,2094.04,,0.007,0.001,1310.928,0.059,0.072,0.0093,22059.614,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-30",14,11.98,2223.87,,0.007,0.001,1396.77,0.059,0.082,0.0109,23499.877,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-08-31",14,12.2,2226.21,,0.007,0.001,1403.389,0.059,0.075,0.0129,23614.579,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-01",13,10.2,1823.18,,0.006,0.001,1154.949,0.059,0.065,0.0148,19434.215,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-02",11,9.2,1442.46,,0.005,0.001,942.674,0.059,0.055,0.0152,15863.383,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-05",15,14.18,2645.48,,0.008,0.001,1674.654,0.059,0.094,0.0095,28182.904,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-06",24,24,4451,,0.014,0.001,2814.9,0.059,0.143,0.006,47369.6,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-07",24,24,4510,,0.014,0.001,2840.3,0.059,0.146,0.0061,47794.7,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-08",23,22.42,4233.15,,0.013,0.001,2655.489,0.059,0.139,0.0063,44680.014,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-09",24,24,4417,,0.014,0.001,2787.2,0.059,0.143,0.0061,46902,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-10",2,0.13,2.38,,0,0.001,4.577,0.059,0.002,0.0605,76.992,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-11",4,3.02,392.28,,0.001,0.001,270.52,0.059,0.019,0.016,4553.804,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-28",8,6.2,1148.42,,0.004,0.001,727.093,0.059,0.045,0.0208,12234.265,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-29",6,4.54,545.39,,0.002,0.001,383.492,0.059,0.024,0.0122,6449.92,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-09-30",10,8.23,1508.31,,0.005,0.001,959.026,0.059,0.055,0.0149,16135.344,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-01",10,8.26,1523.88,,0.005,0.001,972.474,0.059,0.054,0.0123,16364.632,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-05",6,4.74,570.67,,0.002,0.001,401.446,0.059,0.026,0.0115,6754.342,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-16",4,2.75,488.86,,0.002,0.001,313.057,0.059,0.024,0.014,5267.654,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-17",13,12.17,2322.43,,0.007,0.001,1456.371,0.059,0.078,0.0099,24503.818,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-18",12,9.34,1755.13,,0.006,0.001,1106.998,0.059,0.063,0.0131,18626.775,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-19",12,10.33,1905.58,,0.006,0.001,1205.272,0.059,0.067,0.0107,20281.197,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-20",11,9.38,1763.56,,0.006,0.001,1113.72,0.059,0.062,0.0093,18739.968,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-21",7,5.29,981.67,,0.003,0.001,621.629,0.059,0.037,0.0141,10460.9,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-26",6,4.52,865.56,,0.003,0.001,541.738,0.059,0.037,0.015,9116.012,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-03",7,5.27,948.92,,0.003,0.001,602.844,0.059,0.038,0.0181,10143.686,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-04",7,6.27,1191.64,,0.004,0.001,750.438,0.059,0.046,0.0077,12626.133,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-20",21,20.15,3556.85,,0.011,0.001,2267.195,0.059,0.142,0.0109,38152.125,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-21",1,0.07,4.27,,0,0.001,4.011,0.059,0.001,0.037,67.459,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-13",2,0.67,24.62,,0,0.001,31.496,0.059,0.029,0.1,529.873,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Marsh Landing Generating Station",57267,"4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Dry Low NOx Burners,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-09",6,3.18,208.65,,0.001,0.001,119.346,0.0593,0.019,0.0207,2007.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-10",1,0.6,37.2,,0,0.001,21.78,0.059,0.006,0.034,366.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-11",1,0.85,35.7,,0,0.001,23.545,0.059,0.001,0.004,396.185,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-13",3,1.45,65.2,,0,0.001,42,0.0593,0.006,0.024,706.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-17",3,1.45,64.75,,0,0.001,42.25,0.0597,0.007,0.04,710.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-19",2,1.43,65.12,,0,0.001,41.917,0.059,0.008,0.02,705.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-21",5,3.2,288.7,,0.001,0.001,152.24,0.0592,0.02,0.0276,2561.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-25",7,5.17,289.09,,0.001,0.001,174.244,0.0591,0.02,0.0226,2931.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-27",3,1.45,65.2,,0,0.001,42.44,0.059,0.006,0.024,714.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-28",3,1.7,79.72,,0,0.001,50.96,0.0593,0.007,0.0217,857.419,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-29",6,3.9,231.13,,0.001,0.001,136.245,0.0593,0.017,0.0195,2291.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-01",2,1.45,65.3,,0,0.001,42.315,0.0595,0.009,0.02,711.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-03",5,2.9,143.36,,0,0.001,89.199,0.0594,0.016,0.0316,1499.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-04",18,13.44,1186.89,,0.003,0.001,631.305,0.059,0.051,0.0121,10624.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-05",10,6.68,527.94,,0.001,0.001,288.643,0.059,0.03,0.027,4856.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-06",3,1.95,155.16,,0,0.001,85.357,0.059,0.009,0.0217,1435.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-07",10,7.71,616.98,,0.002,0.001,337.277,0.059,0.033,0.0127,5672.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-08",8,5.42,270.92,,0.001,0.001,168.295,0.0594,0.017,0.0161,2830.361,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-09",6,4.4,228.59,,0.001,0.001,139.648,0.059,0.018,0.0182,2349.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-10",2,0.99,58.62,,0,0.001,34.127,0.059,0.014,0.049,574.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-11",9,7.67,573.25,,0.002,0.001,320.042,0.0591,0.032,0.0141,5384.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-12",9,7.17,626.43,,0.002,0.001,336.867,0.059,0.029,0.0177,5668.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-13",9,7.9,531.14,,0.002,0.001,304.426,0.059,0.025,0.0116,5122.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-14",10,8.63,675.17,,0.002,0.001,372.756,0.059,0.032,0.0117,6271.659,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-15",3,1.45,97.35,,0,0.001,55.81,0.059,0.009,0.0227,938.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-16",3,2.45,119.52,,0,0.001,75.848,0.0597,0.009,0.0167,1275.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-17",9,4.64,336.49,,0.001,0.001,188.346,0.0591,0.022,0.0293,3170.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-18",8,5.88,410.95,,0.001,0.001,232.366,0.0593,0.021,0.015,3908.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-19",6,4.4,295.17,,0.001,0.001,167.821,0.0592,0.021,0.018,2824.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-20",9,7.17,477.61,,0.001,0.001,274.71,0.0591,0.023,0.0141,4621.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-21",11,6.84,460.95,,0.001,0.001,263.199,0.0591,0.026,0.0259,4428.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-22",4,3.12,184.68,,0.001,0.001,109.564,0.0595,0.012,0.0295,1843.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-23",14,9.48,773.8,,0.002,0.001,420.224,0.0591,0.032,0.0199,7066.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-24",13,11.17,850.38,,0.002,0.001,472.75,0.059,0.036,0.0098,7956.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-25",8,6.4,447.63,,0.001,0.001,253.48,0.059,0.025,0.0129,4267.981,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-26",11,9.15,734.32,,0.002,0.001,400.296,0.059,0.035,0.011,6736.079,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-27",13,8.85,584.4,,0.002,0.001,333.962,0.059,0.03,0.0279,5620.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-28",12,8.1,533.17,,0.002,0.001,304.758,0.0591,0.029,0.0185,5127.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-02-29",15,11.62,817.58,,0.002,0.001,459.932,0.0591,0.034,0.0148,7741.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-01",9,7.7,637.79,,0.002,0.001,342.138,0.059,0.025,0.0119,5757.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-02",8,6.65,459.02,,0.001,0.001,256.907,0.0593,0.023,0.0124,4322.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-03",10,8.4,694.71,,0.002,0.001,377.318,0.0591,0.033,0.0117,6349.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-04",8,6.4,447.23,,0.001,0.001,251.952,0.0591,0.023,0.0201,4240.402,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-05",10,8.65,579.88,,0.002,0.001,329.844,0.0592,0.025,0.018,5549.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-06",8,6.42,437.71,,0.001,0.001,249.098,0.0591,0.023,0.0109,4192.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-07",7,6.45,501.07,,0.001,0.001,275.971,0.059,0.023,0.0111,4641.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-08",8,6.2,550.68,,0.001,0.001,294.604,0.0591,0.023,0.0195,4959.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-09",13,10.78,917.17,,0.003,0.001,497.788,0.059,0.042,0.0165,8370.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-10",20,19.04,1462.79,,0.004,0.001,810.903,0.0591,0.051,0.0079,13645.451,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-11",21,19.2,1367.08,,0.004,0.001,778.412,0.0592,0.05,0.0114,13094.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-12",18,15.35,1293.45,,0.004,0.001,702.911,0.059,0.048,0.0123,11830.886,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-13",8,7.21,605.84,,0.002,0.001,329.112,0.059,0.024,0.0093,5536.953,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-14",19,16.29,1185.45,,0.003,0.001,667.255,0.0591,0.046,0.0102,11229.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-15",13,10.74,860.54,,0.002,0.001,470.168,0.0591,0.037,0.0104,7911.969,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-16",12,9.87,816.6,,0.002,0.001,441.579,0.0591,0.038,0.01,7429.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-17",14,9.61,629.6,,0.002,0.001,358.344,0.0592,0.03,0.0248,6027.333,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-18",7,4.67,287.84,,0.001,0.001,167.148,0.0591,0.018,0.0239,2811.598,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-19",17,11.86,920.17,,0.003,0.001,505.153,0.059,0.041,0.0189,8503.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-20",8,5.9,336.2,,0.001,0.001,202.15,0.0591,0.019,0.0155,3401.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-21",12,9.4,656.76,,0.002,0.001,371.959,0.0591,0.025,0.016,6259.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-22",8,5.65,418.59,,0.001,0.001,232.201,0.0591,0.022,0.0206,3907.726,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-23",10,6.4,399.32,,0.001,0.001,231.416,0.0593,0.021,0.0229,3894.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-24",7,3.65,220.51,,0.001,0.001,129.419,0.0593,0.014,0.025,2178.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-02",1,0.32,0,,0,0.001,2.336,0.06,0.002,0.098,39.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-03",7,5.33,519.04,,0.001,0.001,272.181,0.059,0.021,0.0189,4581.603,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-04",11,8.37,803.52,,0.002,0.001,422.294,0.059,0.037,0.0165,7106.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-05",11,8.16,662.22,,0.002,0.001,357.702,0.0591,0.027,0.0208,6018.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-06",12,7.2,493.81,,0.001,0.001,276.137,0.059,0.026,0.0224,4645.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-07",14,8.83,577.36,,0.002,0.001,328.742,0.059,0.03,0.025,5530.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-08",10,7.4,525.12,,0.001,0.001,293.897,0.059,0.026,0.0194,4944.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-09",11,7.53,571.81,,0.002,0.001,315.244,0.0592,0.03,0.0235,5302.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-10",15,12.53,1039.16,,0.003,0.001,559.622,0.0591,0.034,0.0116,9416.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-11",4,3.49,302.22,,0.001,0.001,160.925,0.059,0.015,0.011,2708.923,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-12",11,9.07,783.04,,0.002,0.001,415.359,0.0591,0.031,0.0162,6990.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-13",15,10.49,866.51,,0.002,0.001,465.014,0.0591,0.034,0.0187,7826.001,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-14",13,9.66,821.47,,0.002,0.001,442.565,0.0591,0.034,0.0208,7445.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-15",11,6.87,560.61,,0.002,0.001,304.995,0.0591,0.028,0.0297,5130.907,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-16",20,17.66,1095.68,,0.003,0.001,641.29,0.0591,0.046,0.0123,10791.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-17",10,6.66,540.03,,0.001,0.001,293.081,0.0592,0.025,0.0249,4931.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-18",11,6.79,541.77,,0.001,0.001,293.528,0.0592,0.025,0.0284,4940.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-19",17,13.24,1089.95,,0.003,0.001,588.689,0.059,0.039,0.016,9906.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-20",4,2.2,184.2,,0.001,0.001,99.072,0.059,0.011,0.0293,1666.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-21",6,4.33,354.2,,0.001,0.001,193.605,0.059,0.02,0.0135,3257.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-22",15,10.19,788.7,,0.002,0.001,436.886,0.0591,0.035,0.0145,7350.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-23",3,2.31,196.31,,0.001,0.001,106.77,0.059,0.014,0.017,1796.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-24",6,5.7,507.31,,0.001,0.001,272.252,0.059,0.019,0.0092,4581.217,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-25",4,2.95,255.58,,0.001,0.001,138.285,0.0593,0.013,0.0118,2325.929,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-26",4,2.46,227.82,,0.001,0.001,121.281,0.059,0.012,0.0275,2042.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-27",5,3.69,225.98,,0.001,0.001,133.554,0.0592,0.012,0.0232,2247.957,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-28",6,4.95,440.51,,0.001,0.001,237.358,0.059,0.018,0.0207,3996.177,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-29",4,2.95,164.63,,0.001,0.001,99.188,0.0593,0.01,0.0118,1670.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-04-30",9,6.9,375.9,,0.001,0.001,228.858,0.0591,0.021,0.0181,3849.627,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-01",5,3.45,196.49,,0.001,0.001,117.661,0.059,0.012,0.0156,1979.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-02",7,6.87,387.2,,0.001,0.001,232.15,0.0591,0.019,0.0101,3906.734,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-03",13,11.53,598.86,,0.002,0.001,368.875,0.0591,0.026,0.0086,6208.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-04",6,4.45,373.71,,0.001,0.001,201.595,0.059,0.016,0.0218,3392.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-05",5,3.95,283.71,,0.001,0.001,159.563,0.0592,0.011,0.022,2682.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-06",2,1.45,64.41,,0,0.001,41.693,0.059,0.006,0.0175,701.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-07",5,3.7,239.76,,0.001,0.001,137.852,0.059,0.012,0.0262,2319.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-08",9,6.67,429.18,,0.001,0.001,247.9,0.059,0.023,0.019,4171.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-09",8,6.08,490.27,,0.001,0.001,266.645,0.059,0.022,0.0265,4485.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-10",18,15.53,897.12,,0.003,0.001,534.167,0.0593,0.033,0.012,8987.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-11",6,3.16,170.36,,0.001,0.001,101.625,0.059,0.014,0.0373,1710.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-12",10,8.16,504.88,,0.001,0.001,292.932,0.059,0.027,0.0184,4929.634,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-14",8,5.4,370.66,,0.001,0.001,208.5,0.0591,0.023,0.0234,3509.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-15",4,2.45,206.92,,0.001,0.001,111.792,0.059,0.013,0.0308,1881.267,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-16",6,4.95,487.37,,0.001,0.001,255.441,0.059,0.021,0.0143,4300.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-17",3,2.2,201.49,,0.001,0.001,107.148,0.059,0.016,0.0173,1802.157,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-21",7,6.12,420.68,,0.001,0.001,240,0.059,0.018,0.019,4037.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-22",10,9.08,449,,0.001,0.001,281.984,0.0591,0.016,0.0078,4746.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-23",3,2.7,256.75,,0.001,0.001,135.982,0.059,0.016,0.0137,2288.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-24",3,1.7,83.24,,0,0.001,52.17,0.0593,0.007,0.0167,877.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-25",4,3.2,313.28,,0.001,0.001,165.408,0.059,0.016,0.0133,2783.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-26",6,5.45,478.2,,0.001,0.001,257.832,0.059,0.023,0.0105,4338.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-27",6,4.95,330.06,,0.001,0.001,191.059,0.0592,0.015,0.0125,3215.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-28",3,1.47,77.93,,0,0.001,47.541,0.059,0.007,0.036,799.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-30",15,12.66,1036.94,,0.003,0.001,565.57,0.0591,0.036,0.0125,9518.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-05-31",5,3.95,231.95,,0.001,0.001,138.051,0.0592,0.012,0.015,2322.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-01",5,3.45,178.15,,0.001,0.001,109.4,0.059,0.011,0.0248,1840.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-03",4,2.2,102.16,,0,0.001,64.712,0.0593,0.008,0.0315,1090.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-04",5,3.7,176.94,,0.001,0.001,111.282,0.0592,0.011,0.0248,1871.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-05",3,1.45,65.39,,0,0.001,41.752,0.059,0.007,0.037,702.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-09",4,2.45,115.49,,0,0.001,73.235,0.0593,0.008,0.033,1231.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-13",3,2.45,224.9,,0.001,0.001,119.699,0.059,0.016,0.0143,2014.611,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-14",4,2.45,228.86,,0.001,0.001,121.443,0.059,0.014,0.0285,2043.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-15",3,1.45,125.77,,0,0.001,67.592,0.059,0.01,0.0363,1137.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-16",3,2.45,232.6,,0.001,0.001,122.837,0.059,0.016,0.0147,2067.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-17",3,1.95,99.71,,0,0.001,62.118,0.059,0.008,0.0153,1045.791,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-18",5,2.9,201.13,,0.001,0.001,114.71,0.059,0.017,0.028,1931.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-19",3,2.2,204.47,,0.001,0.001,109.622,0.059,0.015,0.014,1845.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-20",4,2.7,257.06,,0.001,0.001,136.994,0.059,0.014,0.0293,2304.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-21",3,2.45,231.31,,0.001,0.001,123.459,0.059,0.016,0.0143,2077.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-22",10,7.19,655.69,,0.002,0.001,350.171,0.0591,0.031,0.0173,5890.959,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-23",3,2.45,228.93,,0.001,0.001,122.258,0.059,0.014,0.016,2056.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-24",4,3.2,304.73,,0.001,0.001,162.373,0.059,0.017,0.012,2731.489,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-26",9,8.2,741.13,,0.002,0.001,396.314,0.059,0.029,0.0114,6668.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-27",10,8.95,820.19,,0.002,0.001,438.372,0.059,0.033,0.0096,7377.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-28",5,3.46,311.5,,0.001,0.001,166.203,0.0592,0.015,0.0244,2797.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-29",9,6.4,472.27,,0.001,0.001,265.109,0.0592,0.024,0.0267,4461.147,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-06-30",9,5.9,489.56,,0.001,0.001,267.25,0.059,0.024,0.0277,4496.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-01",9,6.41,519.68,,0.001,0.001,284.153,0.0591,0.024,0.0193,4779.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-02",6,4.71,443.77,,0.001,0.001,234.948,0.059,0.019,0.0137,3953.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-03",8,6.7,582.6,,0.002,0.001,314.486,0.0591,0.025,0.0113,5290.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-04",10,8.71,681.22,,0.002,0.001,376.537,0.059,0.025,0.0103,6336.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-05",13,11.2,877.2,,0.002,0.001,484.013,0.059,0.032,0.0135,8147.494,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-06",6,5.2,476.34,,0.001,0.001,254.722,0.059,0.02,0.0107,4284.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-07",8,6.04,491.07,,0.001,0.001,269.478,0.0593,0.025,0.0128,4532.857,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-08",4,2.95,285.52,,0.001,0.001,150.879,0.059,0.015,0.013,2538.601,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-09",4,3.72,323.98,,0.001,0.001,175.559,0.059,0.018,0.012,2954.086,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-10",8,6.95,657.23,,0.002,0.001,348.698,0.059,0.028,0.0191,5868.979,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-11",9,8.2,734.8,,0.002,0.001,394.639,0.059,0.029,0.0113,6640.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-12",7,4.66,392.52,,0.001,0.001,211.978,0.059,0.02,0.022,3567.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-13",7,4.91,373.27,,0.001,0.001,206.529,0.059,0.023,0.0131,3475.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-14",3,1.45,102.05,,0,0.001,57.511,0.059,0.008,0.02,967.534,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-15",3,1.45,104.72,,0,0.001,58.524,0.0593,0.007,0.019,985.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-16",3,1.45,64.15,,0,0.001,41.693,0.059,0.006,0.0323,702.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-17",9,7.23,355.7,,0.001,0.001,222.757,0.0594,0.015,0.0171,3746.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-18",4,2.45,115.98,,0,0.001,73.783,0.059,0.008,0.0188,1242.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-19",5,3.2,149.56,,0,0.001,95.408,0.0592,0.01,0.0278,1604.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-20",5,3.2,149.68,,0,0.001,95.532,0.059,0.009,0.0264,1608.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-21",5,3.2,161.36,,0.001,0.001,100.112,0.0592,0.009,0.0258,1685.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-27",11,10.52,511.88,,0.002,0.001,323.924,0.0592,0.022,0.0095,5447.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-28",1,0.08,0,,0,0.001,0.584,0.059,0,0.015,9.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-30",8,6.18,326.1,,0.001,0.001,201.962,0.0591,0.016,0.019,3398.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-07-31",9,7.2,395.36,,0.001,0.001,241.06,0.0591,0.017,0.0177,4056.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-01",8,6.45,346.1,,0.001,0.001,213.032,0.0591,0.016,0.0183,3585.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-03",9,7.85,498.04,,0.001,0.001,291.455,0.059,0.019,0.0098,4904.383,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-13",10,8.7,601.1,,0.002,0.001,340.814,0.0591,0.025,0.0171,5734.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-14",11,10.21,867.26,,0.002,0.001,476.625,0.0591,0.031,0.0088,8018.583,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-15",8,7.21,588.78,,0.002,0.001,322.868,0.059,0.024,0.0098,5434.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-16",6,4.96,243.62,,0.001,0.001,154.058,0.059,0.013,0.0137,2592.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-17",10,8.96,679.96,,0.002,0.001,379.349,0.059,0.022,0.0152,6383.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-18",12,10.95,842.96,,0.002,0.001,469.807,0.059,0.031,0.0073,7904.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-19",10,8.7,695.82,,0.002,0.001,382.35,0.059,0.026,0.0154,6435.941,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-20",11,9.21,687.46,,0.002,0.001,384.59,0.0591,0.026,0.0145,6471.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-21",6,4.96,436.13,,0.001,0.001,235.185,0.059,0.019,0.0223,3958.402,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-24",8,7.63,389.5,,0.001,0.001,242.093,0.059,0.018,0.0103,4074.457,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-25",21,20.32,1003.24,,0.003,0.001,631.496,0.0591,0.037,0.007,10624.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-27",6,4.46,217,,0.001,0.001,137.312,0.0592,0.012,0.0157,2309.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-28",5,3.93,186.92,,0.001,0.001,119.101,0.059,0.011,0.0156,2005.377,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-01",5,4.12,193.39,,0.001,0.001,124.788,0.0592,0.011,0.0194,2099.929,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-05",10,9.9,557.5,,0.002,0.001,340.41,0.0592,0.021,0.0075,5726,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-06",11,9.57,613.97,,0.002,0.001,359.421,0.0591,0.025,0.0085,6049.214,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-08",23,22.62,1117.28,,0.004,0.001,701.632,0.0591,0.044,0.0077,11808.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-09",6,5.5,272,,0.001,0.001,170.5,0.0593,0.01,0.007,2868.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-10",1,0.12,3.96,,0,0.001,2.796,0.059,0.002,0.103,47.124,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-11",5,4.07,193,,0.001,0.001,122.918,0.0594,0.009,0.01,2067.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-16",6,4.2,209.64,,0.001,0.001,131.322,0.0592,0.013,0.0255,2210.421,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-19",7,6.13,298.98,,0.001,0.001,187.966,0.059,0.015,0.0201,3163.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-20",1,0.32,9.92,,0,0.001,7.104,0.059,0,0.008,119.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-01",16,12.98,1022.96,,0.003,0.001,557.475,0.059,0.045,0.0153,9379.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-05",8,7.12,347.8,,0.001,0.001,220.832,0.0595,0.017,0.0185,3712.756,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-06",4,3.82,184.44,,0.001,0.001,117.478,0.059,0.007,0.0073,1976.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-13",8,6.45,310.38,,0.001,0.001,196.964,0.0594,0.015,0.0134,3312.293,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-14",8,7.2,350.46,,0.001,0.001,222.162,0.0593,0.017,0.0119,3737.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-15",8,7.37,354.02,,0.001,0.001,226.852,0.0593,0.017,0.0121,3818.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-16",11,10.2,499.79,,0.002,0.001,316.12,0.059,0.023,0.0092,5320.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-17",6,5.05,247,,0.001,0.001,155.87,0.059,0.009,0.0087,2624.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-04",6,5.61,271.78,,0.001,0.001,174.123,0.0592,0.016,0.0115,2928.873,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-15",6,4.95,307.6,,0.001,0.001,181.325,0.059,0.016,0.0158,3052.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-16",10,7.65,692.9,,0.002,0.001,371.98,0.059,0.031,0.0184,6258.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-19",4,2.2,107.2,,0,0.001,68.285,0.0593,0.009,0.0343,1148.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-13",4,2.7,176.1,,0.001,0.001,100.33,0.059,0.017,0.0295,1687.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-17",2,1.45,65.7,,0,0.001,42.035,0.059,0.007,0.0215,707.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-22",5,3.2,289.7,,0.001,0.001,152.04,0.059,0.018,0.0232,2558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-25",3,1.45,75.25,,0,0.001,46.095,0.0593,0.007,0.0197,775.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-29",2,1.45,110.7,,0,0.001,60.425,0.059,0.011,0.019,1016.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-03",3,1.45,78.6,,0,0.001,47.235,0.059,0.008,0.0307,794.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-04",6,4.4,362,,0.001,0.001,194.425,0.059,0.024,0.0152,3271.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-05",6,4.19,335.53,,0.001,0.001,181.632,0.059,0.026,0.02,3057.191,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-06",3,1.72,116.1,,0,0.001,65.752,0.059,0.008,0.0237,1105.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-08",2,1.47,68.56,,0,0.001,42.813,0.059,0.007,0.022,720.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-09",2,1.7,82.45,,0,0.001,51.34,0.059,0.01,0.0215,865.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-11",6,4.95,397.05,,0.001,0.001,215.84,0.059,0.018,0.0165,3633.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-12",7,5.19,417.62,,0.001,0.001,225.515,0.0591,0.023,0.0173,3794.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-13",9,7.15,442.13,,0.001,0.001,257.557,0.059,0.023,0.0144,4334.281,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-14",6,4.67,322.07,,0.001,0.001,180.992,0.059,0.02,0.0148,3044.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-15",2,1.45,99.8,,0,0.001,56.035,0.059,0.009,0.0195,943.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-16",3,1.95,95.44,,0,0.001,60.152,0.059,0.008,0.0227,1011.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-17",4,3.47,307.87,,0.001,0.001,163.446,0.059,0.017,0.013,2750.825,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-18",3,2.45,186.48,,0.001,0.001,101.98,0.059,0.01,0.015,1715.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-19",8,5.67,437.6,,0.001,0.001,239.125,0.059,0.024,0.0158,4022.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-20",7,4.67,293.2,,0.001,0.001,169.721,0.059,0.019,0.0186,2855.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-21",10,7.9,581.64,,0.002,0.001,322.334,0.0591,0.027,0.012,5421.462,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-23",12,9.22,627.83,,0.002,0.001,355.532,0.0592,0.034,0.0177,5981.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-24",8,6.05,473.37,,0.001,0.001,258.424,0.0593,0.022,0.0106,4348.237,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-25",11,9.15,705.82,,0.002,0.001,386.314,0.0592,0.033,0.0109,6501.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-26",12,9.92,783.61,,0.002,0.001,425.029,0.0591,0.035,0.0106,7151.553,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-27",11,9.15,722.09,,0.002,0.001,392.009,0.0591,0.031,0.0104,6597.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-28",12,9.9,757.74,,0.002,0.001,416.794,0.0593,0.034,0.0105,7010.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-02-29",9,6.42,433.36,,0.001,0.001,245.767,0.059,0.023,0.0192,4137.132,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-01",8,6.97,466.5,,0.001,0.001,263.039,0.0591,0.017,0.0081,4424.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-02",10,8.15,590.41,,0.002,0.001,325.291,0.059,0.028,0.0108,5473.969,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-03",11,9.4,745.37,,0.002,0.001,403.117,0.059,0.031,0.0104,6785.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-04",11,9.15,656.21,,0.002,0.001,364.76,0.059,0.026,0.0093,6138.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-05",11,8.9,625.75,,0.002,0.001,348.141,0.0592,0.029,0.0166,5859.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-06",11,8.15,692.56,,0.002,0.001,370.685,0.0592,0.032,0.0167,6240.339,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-07",7,5.7,406.19,,0.001,0.001,228.601,0.059,0.02,0.0141,3846.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-08",7,5.7,463.08,,0.001,0.001,250.43,0.0591,0.021,0.0107,4214.682,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-09",12,9.9,811.96,,0.002,0.001,439.63,0.0591,0.036,0.0105,7397.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-10",16,13.91,1075.07,,0.003,0.001,589.696,0.0592,0.043,0.0104,9922.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-11",21,19.2,1356.48,,0.004,0.001,765.96,0.059,0.047,0.0108,12889.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-12",12,10.1,801.68,,0.002,0.001,439.394,0.0591,0.036,0.0103,7394.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-02",8,5.99,481.65,,0.001,0.001,261.983,0.059,0.021,0.0144,4408.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-03",10,7.41,565.59,,0.002,0.001,311.585,0.0591,0.025,0.013,5244.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-04",10,8.71,645.04,,0.002,0.001,360.004,0.0591,0.022,0.0096,6056.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-05",11,10.44,759.52,,0.002,0.001,425.282,0.0591,0.027,0.0083,7155.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-06",8,6.2,528.36,,0.001,0.001,284.48,0.0591,0.017,0.02,4787.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-07",7,5.2,451.68,,0.001,0.001,241.896,0.0591,0.019,0.0219,4068.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-08",6,4.2,368.24,,0.001,0.001,196.92,0.059,0.015,0.0222,3313.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-09",8,6.2,511.32,,0.001,0.001,277.292,0.059,0.023,0.0265,4664.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-10",10,8.95,781.9,,0.002,0.001,419.693,0.059,0.029,0.0172,7060.929,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-11",11,10.2,840.3,,0.002,0.001,459.044,0.059,0.029,0.0082,7725.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-12",10,8.66,616.54,,0.002,0.001,346.238,0.059,0.027,0.01,5824.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-13",9,7.95,531.21,,0.002,0.001,303.608,0.0591,0.027,0.0101,5108.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-14",8,6.22,480.92,,0.001,0.001,263.962,0.059,0.019,0.0191,4441.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-15",8,6.2,527.56,,0.001,0.001,284.06,0.059,0.021,0.0186,4779.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-16",12,8.41,626.84,,0.002,0.001,348.813,0.0593,0.027,0.0217,5866.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-17",10,6.89,505.8,,0.001,0.001,281.779,0.059,0.021,0.0252,4741.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-18",7,6.45,509.59,,0.001,0.001,280.085,0.059,0.024,0.0103,4713.089,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-19",6,4.2,319.24,,0.001,0.001,176.968,0.059,0.015,0.0248,2977.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-20",7,5.2,400.6,,0.001,0.001,220,0.059,0.017,0.02,3701.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-21",7,5.2,459.6,,0.001,0.001,245.6,0.059,0.02,0.0207,4133.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-22",11,9.15,659.02,,0.002,0.001,369.567,0.059,0.028,0.0166,6218.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-23",6,4.2,327.6,,0.001,0.001,179.7,0.059,0.017,0.0242,3024.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-24",7,5.95,494.73,,0.001,0.001,267.745,0.059,0.024,0.0106,4506.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-25",8,6.95,564.09,,0.002,0.001,307.53,0.059,0.025,0.0198,5175.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-26",9,8.12,668.92,,0.002,0.001,363.944,0.059,0.028,0.0186,6125.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-27",11,9.53,693.4,,0.002,0.001,387.114,0.059,0.026,0.0091,6515.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-28",8,6.45,560.1,,0.002,0.001,300.124,0.059,0.023,0.0196,5051.549,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-29",9,7.2,603.36,,0.002,0.001,328,0.0591,0.022,0.0176,5519.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-30",10,7.66,623.75,,0.002,0.001,341.433,0.0591,0.027,0.0183,5744.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-07-31",11,9.95,841.8,,0.002,0.001,457.054,0.0591,0.029,0.0084,7689.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-01",4,2.95,242.19,,0.001,0.001,132.264,0.059,0.011,0.0163,2225.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-03",7,5.95,394.37,,0.001,0.001,226.571,0.0593,0.015,0.0091,3811.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-04",4,2.95,250.31,,0.001,0.001,134.877,0.0593,0.014,0.0133,2268.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-05",5,3.7,331,,0.001,0.001,176.814,0.059,0.017,0.0262,2974.574,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-06",5,3.46,305.11,,0.001,0.001,163.305,0.059,0.016,0.028,2748.161,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-07",7,5.65,423.15,,0.001,0.001,235.467,0.0591,0.022,0.012,3960.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-08",6,4.45,404.11,,0.001,0.001,215.118,0.059,0.019,0.0235,3619.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-09",7,5.2,444.84,,0.001,0.001,238.32,0.059,0.016,0.0206,4010.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-10",9,7.7,610.2,,0.002,0.001,334.17,0.059,0.023,0.01,5621.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-11",5,3.2,275.24,,0.001,0.001,147.768,0.059,0.013,0.0284,2488.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-12",9,8.2,662.96,,0.002,0.001,361.048,0.059,0.028,0.0099,6074.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-13",10,8.7,545.66,,0.002,0.001,317.438,0.059,0.023,0.0174,5340.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-14",10,9.21,748,,0.002,0.001,408.466,0.059,0.026,0.0105,6872.359,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-15",9,7.7,559.48,,0.002,0.001,313.952,0.0591,0.019,0.0167,5282.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-16",6,3.4,163.86,,0.001,0.001,102.705,0.0593,0.012,0.0375,1726.793,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-17",13,11.21,786.38,,0.002,0.001,443.545,0.059,0.028,0.0144,7464.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-18",12,11.19,949.31,,0.003,0.001,513.75,0.059,0.035,0.0082,8644.365,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-19",14,11.65,850.76,,0.002,0.001,476.869,0.0591,0.032,0.0141,8024.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-20",10,8.2,552.04,,0.002,0.001,314.965,0.0593,0.021,0.0154,5298.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-21",10,7.41,605.93,,0.002,0.001,330.163,0.059,0.025,0.0187,5554.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-22",7,6.2,515.34,,0.001,0.001,280.24,0.059,0.021,0.0099,4715.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-23",10,7.16,594.55,,0.002,0.001,321.982,0.0591,0.028,0.0263,5417.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-24",10,8.71,777.11,,0.002,0.001,414.956,0.059,0.029,0.0169,6982.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-25",9,6.65,482.96,,0.001,0.001,270.803,0.0593,0.023,0.0134,4554.967,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-26",6,4.41,282.79,,0.001,0.001,163.241,0.059,0.019,0.014,2747.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-27",10,8.69,768.11,,0.002,0.001,412.68,0.059,0.031,0.0119,6944.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-28",7,5.24,357.47,,0.001,0.001,203.209,0.0591,0.019,0.0141,3417.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-29",3,1.45,72.32,,0,0.001,44.957,0.059,0.008,0.024,756.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-30",6,4.2,271.9,,0.001,0.001,156.2,0.059,0.013,0.024,2627.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-08-31",4,2.2,176.42,,0,0.001,96.595,0.0593,0.011,0.031,1626.139,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-01",2,1.46,116.6,,0,0.001,63.453,0.059,0.01,0.02,1068.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-02",4,2.2,183.68,,0.001,0.001,100.738,0.059,0.012,0.031,1694.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-03",4,2.96,251.8,,0.001,0.001,137.222,0.059,0.014,0.0333,2308.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-04",8,6.71,579.56,,0.002,0.001,314.945,0.059,0.023,0.0248,5299.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-05",10,8.7,619.55,,0.002,0.001,353.112,0.059,0.023,0.0173,5939.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-06",5,4.45,342.59,,0.001,0.001,190.709,0.059,0.017,0.0124,3207.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-07",8,4.67,252.33,,0.001,0.001,152.985,0.059,0.015,0.0301,2574.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-08",5,3.72,174.25,,0.001,0.001,110.426,0.059,0.008,0.0086,1859.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-10",11,7.31,535.67,,0.002,0.001,297.653,0.0592,0.029,0.0276,5009.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-11",13,10.52,701.01,,0.002,0.001,400.751,0.0592,0.029,0.0155,6743.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-12",10,8.21,748.07,,0.002,0.001,396.855,0.0592,0.029,0.0179,6678.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-13",12,10.2,926.2,,0.002,0.001,493.079,0.059,0.035,0.0159,8293.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-14",7,5.2,417.68,,0.001,0.001,228.764,0.0593,0.018,0.0213,3848.133,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-15",6,4.2,327.94,,0.001,0.001,180.729,0.0592,0.015,0.0257,3041.454,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-16",12,10.2,662.9,,0.002,0.001,384.978,0.059,0.03,0.0173,6483.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-17",6,4.45,315.06,,0.001,0.001,177.761,0.0592,0.015,0.0257,2990.723,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-18",12,8.55,573.95,,0.002,0.001,326.267,0.0591,0.03,0.0242,5492.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-19",21,18.92,1290.85,,0.004,0.001,730.78,0.059,0.049,0.0113,12298.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-20",18,14.19,1085.27,,0.003,0.001,594.475,0.0591,0.044,0.0176,10000.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-21",10,7.68,656.65,,0.002,0.001,350.577,0.0591,0.028,0.0124,5900.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-22",8,5.66,445.21,,0.001,0.001,242.837,0.0591,0.022,0.028,4085.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-23",6,4.7,357.67,,0.001,0.001,196.541,0.059,0.016,0.0245,3305.917,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-24",18,14.41,1021.71,,0.003,0.001,571.195,0.0592,0.042,0.0139,9612.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-25",17,14.67,1116.16,,0.003,0.001,617.009,0.059,0.045,0.018,10384.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-26",6,4.2,371.94,,0.001,0.001,197.735,0.059,0.018,0.0248,3325.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-27",6,4.46,288.79,,0.001,0.001,164.618,0.0592,0.014,0.0237,2769.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-29",3,1.95,160.17,,0,0.001,86.452,0.059,0.011,0.044,1454.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-03",11,9.58,707.91,,0.002,0.001,391.5,0.059,0.036,0.0198,6587.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-04",18,13.49,1158.22,,0.003,0.001,619.608,0.0591,0.044,0.0173,10426.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-05",6,4.7,368.29,,0.001,0.001,201.742,0.0592,0.016,0.01,3395.019,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-07",7,4.65,313.65,,0.001,0.001,178.392,0.0591,0.021,0.0247,3001.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-08",9,6.65,497.08,,0.001,0.001,274.939,0.0592,0.025,0.0203,4624.965,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-09",6,3.55,304.66,,0.001,0.001,162.835,0.0592,0.015,0.0385,2741.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-10",13,8.55,721.17,,0.002,0.001,387.859,0.0591,0.034,0.0297,6529.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-11",19,16.52,1476.12,,0.004,0.001,788.24,0.0591,0.051,0.0119,13260.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-12",6,4.2,362.59,,0.001,0.001,195.441,0.059,0.018,0.0245,3288.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-13",8,6.2,298.11,,0.001,0.001,190.114,0.059,0.016,0.0205,3200.324,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-14",7,5.95,287,,0.001,0.001,182.774,0.059,0.016,0.0106,3076.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-15",8,7.88,387,,0.001,0.001,244.644,0.0591,0.02,0.0103,4117.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-16",3,2.57,119.66,,0,0.001,76.706,0.059,0.005,0.007,1291.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-18",15,13.17,957.58,,0.003,0.001,537.387,0.059,0.043,0.0105,9042.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-19",9,6.17,390.59,,0.001,0.001,227.129,0.0592,0.022,0.0192,3820.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-20",7,5.2,451.81,,0.001,0.001,242.935,0.059,0.02,0.0231,4086.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-21",8,6.15,450.13,,0.001,0.001,250.99,0.059,0.025,0.0151,4223.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-22",6,4.2,358.46,,0.001,0.001,192.783,0.0592,0.017,0.0253,3242.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-23",2,0.43,0.18,,0,0.001,3.329,0.0595,0.003,0.1065,55.969,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-26",5,2.39,171.21,,0,0.001,94.258,0.059,0.019,0.044,1586.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-27",5,3.4,258.08,,0.001,0.001,140.643,0.059,0.02,0.0196,2365.982,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-28",20,18.42,1625.59,,0.004,0.001,858.962,0.0591,0.062,0.0089,14453.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-29",9,5.65,434.87,,0.001,0.001,237.707,0.0591,0.022,0.0279,4000.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-30",7,5.1,455.1,,0.001,0.001,239.812,0.059,0.023,0.0253,4034.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-10-31",19,17.19,1468.91,,0.004,0.001,780.178,0.059,0.054,0.0087,13130.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-01",19,13.21,1083.43,,0.003,0.001,580.541,0.0591,0.043,0.0205,9769.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-02",8,6.2,558.11,,0.001,0.001,293.39,0.0591,0.024,0.0201,4938.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-03",5,3.45,247.26,,0.001,0.001,137.509,0.0592,0.013,0.0164,2311.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-04",6,5.18,447.6,,0.001,0.001,238.002,0.059,0.019,0.0117,4006.639,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-05",10,8.6,723.68,,0.002,0.001,386.131,0.059,0.031,0.0178,6497.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-06",16,13.99,1069.81,,0.003,0.001,580.737,0.059,0.038,0.0084,9770.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-07",12,7.29,466.73,,0.001,0.001,263.724,0.059,0.031,0.0317,4437.339,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-08",13,8.13,551.05,,0.002,0.001,306.721,0.0592,0.028,0.0224,5159.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-09",7,4.52,366.75,,0.001,0.001,195.831,0.0591,0.017,0.0234,3294.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-10",11,7.65,652.29,,0.002,0.001,343.3,0.0591,0.029,0.0195,5776.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-11",8,6.4,488.63,,0.001,0.001,265.88,0.0591,0.025,0.0218,4474.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-12",9,6.65,490.09,,0.001,0.001,268.867,0.0591,0.024,0.0216,4525.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-13",9,6.05,423.87,,0.001,0.001,235.393,0.0591,0.026,0.0248,3961.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-14",10,6.24,460.08,,0.001,0.001,252.434,0.0591,0.021,0.0196,4247.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-15",11,8.17,633.24,,0.002,0.001,343.669,0.0591,0.029,0.0178,5781.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-16",10,6.42,425.25,,0.001,0.001,239.291,0.0592,0.021,0.028,4026.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-17",6,4.7,406.6,,0.001,0.001,214.95,0.059,0.017,0.0135,3615.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-18",8,5.65,316.04,,0.001,0.001,186.713,0.0591,0.021,0.0225,3142.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-19",5,3.7,270.05,,0.001,0.001,148.577,0.0592,0.013,0.026,2499.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-20",8,5.9,416.97,,0.001,0.001,231.638,0.0593,0.023,0.0231,3897.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-21",6,5.43,438.09,,0.001,0.001,236.755,0.059,0.021,0.0113,3981.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-22",10,7.14,429.3,,0.001,0.001,249.224,0.0592,0.027,0.0188,4192.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-23",5,3.18,278.11,,0.001,0.001,146.209,0.0594,0.014,0.0252,2459.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-24",9,6.67,542.35,,0.001,0.001,291.588,0.0591,0.028,0.0218,4907.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-25",7,5.17,351.24,,0.001,0.001,197.199,0.0591,0.022,0.0259,3320.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-26",11,7.67,604.3,,0.002,0.001,326.041,0.0591,0.029,0.0208,5485.857,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-27",6,4.2,368.3,,0.001,0.001,193.9,0.0593,0.016,0.0255,3262.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-28",7,5.45,475.6,,0.001,0.001,250.165,0.059,0.02,0.0141,4209.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-29",8,7.22,582.74,,0.002,0.001,313.886,0.0591,0.025,0.0101,5280.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-11-30",9,7.18,530.2,,0.001,0.001,292.224,0.0591,0.022,0.0166,4919.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-01",13,10.62,688.55,,0.002,0.001,396.603,0.059,0.031,0.0176,6677.837,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-02",8,5.47,410.95,,0.001,0.001,226.763,0.0591,0.022,0.0165,3815.163,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-03",9,6.92,505.13,,0.001,0.001,281.147,0.0592,0.027,0.0149,4728.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-04",15,11.65,800.96,,0.002,0.001,447.771,0.0591,0.033,0.0181,7534.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-05",7,5.45,421.9,,0.001,0.001,227.82,0.059,0.017,0.0213,3834.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-06",7,5.97,509.39,,0.001,0.001,267.683,0.059,0.021,0.0113,4503.349,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-07",8,5.9,439.75,,0.001,0.001,239.025,0.0593,0.025,0.024,4022.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-08",10,6.38,429.77,,0.001,0.001,240.519,0.0591,0.025,0.0312,4047.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-09",8,5.35,369.15,,0.001,0.001,204.285,0.0593,0.026,0.0259,3437.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-10",8,5.65,398.1,,0.001,0.001,218.86,0.059,0.022,0.0228,3684.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-11",8,6.19,442.44,,0.001,0.001,243.803,0.059,0.025,0.0229,4105.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-12",8,6.95,604.9,,0.002,0.001,317.875,0.059,0.025,0.0194,5349.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-13",7,5.47,447,,0.001,0.001,239.378,0.0593,0.019,0.014,4026.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-14",4,2.2,126.35,,0,0.001,74.43,0.059,0.009,0.0318,1253.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-13",2,1.45,66.55,,0,0.001,42.375,0.059,0.008,0.024,713.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-17",3,1.45,65.75,,0,0.001,42.275,0.0593,0.009,0.0477,710.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-19",2,1.45,65.3,,0,0.001,42.145,0.059,0.01,0.0225,709.295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-22",5,3.22,289.9,,0.001,0.001,155.138,0.059,0.025,0.0328,2611.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-25",3,1.97,94.87,,0,0.001,60.116,0.0593,0.009,0.0187,1011.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-28",1,0.32,2.24,,0,0.001,3.52,0.059,0.004,0.135,59.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-29",3,1.47,99.27,,0,0.001,56.475,0.059,0.009,0.018,949.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-03",2,0.29,1.88,,0,0.001,3.103,0.0595,0.004,0.151,52.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-04",5,2.92,212.26,,0.001,0.001,118.507,0.0592,0.007,0.0094,1993.733,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-05",5,4.19,336.88,,0.001,0.001,184.386,0.059,0.028,0.0186,3101.808,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-06",3,1.72,131.1,,0,0.001,72.899,0.059,0.01,0.0263,1227.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-08",3,1.4,59.44,,0,0.001,38.748,0.059,0.006,0.0297,652.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-09",3,1.97,102.72,,0,0.001,62.788,0.059,0.012,0.0173,1057.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-10",1,0.48,23.04,,0,0.001,14.064,0.059,0.011,0.09,236.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-11",9,6.67,492.27,,0.001,0.001,274.891,0.0591,0.027,0.0194,4625.191,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-12",8,6.19,521.96,,0.001,0.001,282.299,0.0591,0.028,0.017,4749.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-13",9,7.17,477.23,,0.001,0.001,273.997,0.059,0.025,0.0156,4611.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-14",7,5.67,396.23,,0.001,0.001,224.723,0.059,0.027,0.015,3781.137,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-15",2,1.72,117.32,,0,0.001,67.321,0.059,0.014,0.021,1131.871,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-16",3,1.95,100.28,,0,0.001,62.383,0.059,0.009,0.0253,1049.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-17",4,3.72,334.04,,0.001,0.001,179.286,0.059,0.02,0.0145,3015.113,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-18",5,3.9,274.41,,0.001,0.001,154.605,0.0592,0.021,0.018,2602.437,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-19",8,5.94,461.98,,0.001,0.001,254.445,0.059,0.026,0.017,4281.577,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-20",7,4.69,301.51,,0.001,0.001,174.24,0.059,0.02,0.0211,2929.935,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-21",9,7.17,505.36,,0.001,0.001,286.108,0.059,0.028,0.013,4814.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-23",7,5.95,472.37,,0.001,0.001,260.058,0.059,0.022,0.0113,4375.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-24",6,4.95,377.59,,0.001,0.001,209.246,0.059,0.02,0.0117,3520.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-25",9,6.61,447.77,,0.001,0.001,255.215,0.0591,0.03,0.0146,4294.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-26",11,9.17,703.59,,0.002,0.001,388.151,0.0592,0.033,0.0108,6530.659,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-27",7,4.9,363.34,,0.001,0.001,201.944,0.0591,0.022,0.0129,3398.037,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-28",10,6.85,483.86,,0.001,0.001,273.087,0.0591,0.03,0.0132,4594.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-02-29",7,6.22,477.44,,0.001,0.001,263.494,0.059,0.023,0.0114,4433.023,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-01",8,6.97,519.5,,0.001,0.001,286.926,0.059,0.024,0.0109,4827.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-02",10,8.15,620.55,,0.002,0.001,340.122,0.0591,0.031,0.0117,5724.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-03",11,8.9,735.11,,0.002,0.001,397.501,0.059,0.035,0.0138,6688.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-04",9,7.4,477.5,,0.001,0.001,274.246,0.0591,0.025,0.0116,4613.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-05",11,8.65,573.55,,0.002,0.001,327.165,0.0591,0.029,0.0184,5504.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-06",10,8.4,544.66,,0.002,0.001,314.456,0.0591,0.027,0.0113,5291.929,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-07",7,4.67,312.12,,0.001,0.001,178.988,0.059,0.021,0.0247,3012.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-08",7,5.45,450.35,,0.001,0.001,244.976,0.0591,0.02,0.015,4122.922,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-09",11,9.4,766.3,,0.002,0.001,419.612,0.0591,0.036,0.0113,7060.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-10",13,11.4,944.57,,0.003,0.001,515.444,0.0592,0.042,0.0106,8672.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-11",11,8.65,755.58,,0.002,0.001,407.268,0.0591,0.035,0.0182,6852.689,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-12",18,16.12,1228.71,,0.003,0.001,687.382,0.059,0.049,0.0091,11569.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-13",7,6.2,496.05,,0.001,0.001,272.203,0.059,0.021,0.0099,4578.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-14",18,16.16,1137.51,,0.003,0.001,647.346,0.0591,0.048,0.0092,10893.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-15",12,9.15,729.81,,0.002,0.001,401.253,0.0592,0.037,0.0178,6750.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-16",13,10.16,861.2,,0.002,0.001,464.364,0.059,0.039,0.0162,7813.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-17",15,12.91,1035,,0.003,0.001,564.004,0.0591,0.044,0.0102,9493.499,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-18",10,7.13,480.3,,0.001,0.001,273.259,0.0591,0.031,0.0127,4599.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-19",10,8.15,550.96,,0.002,0.001,314.691,0.0593,0.029,0.0112,5293.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-20",10,7.65,518.24,,0.001,0.001,296.206,0.0593,0.029,0.0197,4984.467,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-21",15,11.41,694.72,,0.002,0.001,409.823,0.0591,0.031,0.0203,6895.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-22",6,4.95,366.37,,0.001,0.001,204.084,0.0592,0.019,0.0123,3435.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-23",5,3.95,298.37,,0.001,0.001,165.271,0.0592,0.017,0.0128,2781.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-24",6,4.16,308.53,,0.001,0.001,172.351,0.059,0.021,0.014,2899.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-25",15,9.87,662.82,,0.002,0.001,380.152,0.0593,0.034,0.0238,6396.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-26",6,4.45,371.46,,0.001,0.001,200.392,0.059,0.019,0.0252,3373.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-27",12,8.4,622.24,,0.002,0.001,347.276,0.059,0.031,0.0247,5841.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-28",10,7.65,569.2,,0.002,0.001,316.615,0.0591,0.028,0.0194,5324.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-29",5,4.2,306.06,,0.001,0.001,169.681,0.059,0.017,0.013,2855.739,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-30",11,7.4,604.48,,0.002,0.001,326.224,0.059,0.025,0.0186,5488.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-03-31",8,5.9,421.6,,0.001,0.001,235.265,0.0593,0.025,0.0159,3957.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-01",9,5.65,447.1,,0.001,0.001,244.629,0.0591,0.025,0.0237,4117.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-02",8,5.15,398.92,,0.001,0.001,220.283,0.059,0.023,0.0264,3705.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-03",10,6.55,550.46,,0.001,0.001,296.607,0.0591,0.033,0.0296,4989.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-04",16,13.16,1158.48,,0.003,0.001,621.056,0.0591,0.044,0.0133,10448.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-05",16,11.49,1009.4,,0.003,0.001,537.938,0.0592,0.042,0.0187,9050.223,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-06",12,6.61,548.62,,0.001,0.001,296.075,0.0591,0.031,0.0303,4982.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-07",11,6.87,457.81,,0.001,0.001,260.66,0.0592,0.028,0.0256,4385.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-08",7,4.9,253.94,,0.001,0.001,156.096,0.0593,0.02,0.0246,2627.153,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-09",13,8.24,614.37,,0.002,0.001,341.167,0.0592,0.037,0.0249,5738.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-10",6,3.78,285.31,,0.001,0.001,157.635,0.0592,0.015,0.0232,2653.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-11",5,3.95,327.64,,0.001,0.001,176.471,0.0592,0.019,0.0126,2969.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-12",7,6.87,596.24,,0.002,0.001,319.366,0.059,0.026,0.0111,5375.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-13",14,9.2,750.84,,0.002,0.001,406.422,0.0591,0.038,0.0163,6839.787,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-14",8,6.45,584.36,,0.002,0.001,312.044,0.059,0.026,0.02,5251.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-15",8,4.87,304.51,,0.001,0.001,176.645,0.0591,0.022,0.0231,2971.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-16",8,6.95,584.24,,0.002,0.001,317.232,0.0593,0.026,0.0108,5337.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-17",11,8.15,617.89,,0.002,0.001,341.714,0.0592,0.032,0.0188,5750.354,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-18",11,7.53,592.23,,0.002,0.001,325.118,0.059,0.032,0.0253,5472.103,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-19",14,11.79,911.23,,0.003,0.001,502.731,0.0591,0.034,0.0135,8462.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-20",5,3.96,315.88,,0.001,0.001,173.1,0.0592,0.017,0.0126,2912.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-21",4,3.7,255.17,,0.001,0.001,145.686,0.059,0.015,0.0135,2450.711,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-22",8,5.92,416.2,,0.001,0.001,235.752,0.0593,0.023,0.0125,3966.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-23",6,4.45,389.88,,0.001,0.001,209.671,0.059,0.018,0.0143,3526.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-24",6,5.7,515.49,,0.001,0.001,277.241,0.059,0.024,0.0113,4666.059,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-25",4,2.95,244.95,,0.001,0.001,133.986,0.0593,0.016,0.0128,2254.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-26",6,4.96,421.76,,0.001,0.001,228.84,0.0592,0.02,0.0113,3850.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-27",4,3.45,226.82,,0.001,0.001,131.255,0.059,0.014,0.0138,2209.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-28",6,4.66,357.51,,0.001,0.001,199.486,0.059,0.023,0.0148,3355.531,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-29",9,5.66,298.12,,0.001,0.001,183.132,0.0592,0.02,0.0281,3082.986,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-04-30",5,3.95,207.63,,0.001,0.001,128.101,0.0596,0.012,0.0124,2154.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-01",5,3.47,180.38,,0.001,0.001,110.9,0.059,0.013,0.0178,1866.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-02",5,4.2,239.17,,0.001,0.001,143.011,0.059,0.015,0.0126,2407.371,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-03",5,4.2,338.74,,0.001,0.001,184.865,0.059,0.017,0.0126,3109.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-04",6,4.97,420.37,,0.001,0.001,227.709,0.0592,0.02,0.0113,3831.279,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-05",6,4.2,326.2,,0.001,0.001,180.38,0.059,0.016,0.0243,3034.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-06",3,2.45,122.6,,0,0.001,76.113,0.0593,0.011,0.016,1281.141,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-07",3,1.7,123.85,,0,0.001,69.306,0.059,0.009,0.022,1165.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-08",4,3.45,263.38,,0.001,0.001,145.756,0.059,0.016,0.014,2452.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-09",6,4.7,365.02,,0.001,0.001,200.666,0.0592,0.018,0.0217,3377.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-10",14,11.32,650.48,,0.002,0.001,389.032,0.059,0.03,0.0201,6547.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-11",11,8.8,574.92,,0.002,0.001,329.191,0.059,0.024,0.016,5537.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-12",5,3.7,305.32,,0.001,0.001,164.846,0.0592,0.016,0.0256,2772.986,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-16",4,2.95,257.26,,0.001,0.001,138.345,0.0593,0.014,0.028,2327.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-17",4,2.2,185.96,,0.001,0.001,99.896,0.0593,0.012,0.0293,1681.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-22",4,2.45,208.3,,0.001,0.001,112.319,0.0593,0.013,0.029,1889.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-25",3,1.7,148.18,,0,0.001,80.106,0.059,0.012,0.0163,1348.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-26",6,5.45,427.88,,0.001,0.001,237.733,0.0592,0.022,0.0108,4000.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-27",3,1.7,131.02,,0,0.001,73.05,0.0593,0.011,0.038,1229.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-30",9,7.7,614.41,,0.002,0.001,337.404,0.059,0.021,0.0098,5678.162,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-01",3,1.45,81.48,,0,0.001,48.611,0.0593,0.009,0.0393,818.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-03",4,2.2,103.4,,0,0.001,65.108,0.0595,0.009,0.0348,1095.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-08",3,1.45,69.96,,0,0.001,43.539,0.0593,0.008,0.0443,733.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-13",4,2.2,157.08,,0,0.001,88.492,0.059,0.01,0.0318,1489.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-14",4,2.46,213.64,,0.001,0.001,114.648,0.059,0.013,0.0185,1929.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-15",1,0.25,1.75,,0,0.001,2.825,0.059,0.003,0.129,47.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-16",6,3.66,312.51,,0.001,0.001,169.282,0.059,0.023,0.0268,2848.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-17",2,1.45,74.36,,0,0.001,46.15,0.059,0.007,0.021,776.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-18",2,1.45,109.34,,0,0.001,61.155,0.059,0.011,0.022,1029.778,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-20",4,2.96,268.96,,0.001,0.001,145.875,0.059,0.017,0.0148,2454.573,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-21",3,1.95,170.71,,0,0.001,93.059,0.0593,0.013,0.017,1565.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-22",3,2.46,209.05,,0.001,0.001,113.408,0.059,0.014,0.017,1908.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-23",9,6.67,595.5,,0.002,0.001,321.25,0.059,0.036,0.0208,5409.263,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-24",4,2.96,269.33,,0.001,0.001,145.967,0.059,0.018,0.0155,2458.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-26",7,5.96,513.39,,0.001,0.001,277.567,0.0591,0.025,0.0233,4667.634,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-27",4,2.71,245.8,,0.001,0.001,130.925,0.059,0.015,0.0313,2203.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-28",3,1.95,172.17,,0,0.001,92.353,0.059,0.015,0.0163,1554.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-29",3,1.96,170,,0,0.001,91.817,0.059,0.013,0.0173,1545.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-06-30",4,3.21,281.41,,0.001,0.001,152.407,0.059,0.016,0.018,2564.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-01",4,2.96,263.33,,0.001,0.001,141.423,0.0593,0.016,0.0143,2379.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-02",3,2.46,219.54,,0.001,0.001,117.472,0.059,0.017,0.016,1976.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-03",5,3.71,343.38,,0.001,0.001,183.341,0.059,0.019,0.0272,3086.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-04",4,2.71,237.64,,0.001,0.001,128.203,0.059,0.015,0.0318,2156.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-05",4,2.96,267.99,,0.001,0.001,143.821,0.059,0.016,0.0323,2419.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-06",5,3.7,342.4,,0.001,0.001,183.326,0.059,0.019,0.0266,3082.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-07",4,3.2,292.58,,0.001,0.001,156.034,0.059,0.017,0.0145,2626.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-08",3,1.7,146.78,,0,0.001,79.266,0.059,0.012,0.0403,1333.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-09",4,3.2,278.47,,0.001,0.001,150.562,0.059,0.018,0.0133,2534.554,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-10",7,6.45,588.93,,0.002,0.001,314.443,0.059,0.031,0.0119,5291.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-11",7,5.95,536.13,,0.001,0.001,288.955,0.0591,0.025,0.021,4863.619,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-12",8,5.91,467.1,,0.001,0.001,256.967,0.0591,0.025,0.02,4323.821,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-13",4,2.95,233.76,,0.001,0.001,128.443,0.059,0.015,0.0145,2161.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-14",3,1.45,96.94,,0,0.001,55.504,0.059,0.006,0.0173,933.459,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-15",3,1.45,104.05,,0,0.001,58.174,0.0593,0.007,0.0163,978.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-16",3,1.45,93.91,,0,0.001,54.281,0.059,0.005,0.016,913.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-17",3,1.45,89.09,,0,0.001,51.937,0.059,0.007,0.0293,874.157,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-18",4,2.45,139.56,,0,0.001,83.498,0.059,0.008,0.0223,1405.553,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-19",3,1.45,75.36,,0,0.001,45.935,0.0593,0.006,0.029,773.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-20",4,2.2,113.28,,0,0.001,69.92,0.0593,0.008,0.0225,1176.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-21",5,3.2,220.28,,0.001,0.001,125.72,0.0592,0.01,0.0192,2115.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-22",4,2.95,223.75,,0.001,0.001,124.228,0.059,0.013,0.0243,2091.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-24",3,1.95,170.51,,0,0.001,92.2,0.059,0.011,0.029,1552.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-25",5,3.71,334.24,,0.001,0.001,178.607,0.0592,0.016,0.02,3005.403,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-26",5,3.7,348.02,,0.001,0.001,186.904,0.0592,0.017,0.0202,3144.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-27",5,4.2,374.04,,0.001,0.001,201.381,0.059,0.019,0.0108,3387.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-28",3,1.96,168.18,,0,0.001,90.871,0.059,0.01,0.013,1529.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-29",4,2.95,245.5,,0.001,0.001,134.51,0.059,0.012,0.0153,2263.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-30",8,6.18,325,,0.001,0.001,200.394,0.0591,0.016,0.0136,3371.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-07-31",7,5.95,496.51,,0.001,0.001,272.629,0.059,0.02,0.0114,4587.247,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-01",3,1.46,121.26,,0,0.001,65.896,0.059,0.008,0.0173,1108.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-13",5,4.46,309.44,,0.001,0.001,175.276,0.059,0.014,0.0098,2949.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-14",9,7.71,672.49,,0.002,0.001,364.195,0.059,0.026,0.0136,6129.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-15",4,2.71,239.51,,0.001,0.001,128.848,0.0593,0.013,0.0235,2169.583,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-17",10,8.7,656.67,,0.002,0.001,367.198,0.0591,0.023,0.0129,6177.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-18",12,10.71,874.84,,0.002,0.001,482.798,0.059,0.033,0.0094,8124.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-19",7,6.21,446.29,,0.001,0.001,252.728,0.059,0.019,0.0093,4253.003,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-20",5,3.7,217.39,,0.001,0.001,129.623,0.059,0.011,0.0112,2182.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-21",3,2.46,173.36,,0,0.001,98.73,0.059,0.012,0.0123,1662.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-22",5,3.41,230.9,,0.001,0.001,131.825,0.0592,0.014,0.011,2217.661,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-23",5,4.46,354.96,,0.001,0.001,196.238,0.059,0.016,0.01,3302.194,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-24",8,7.71,631.8,,0.002,0.001,346.832,0.059,0.029,0.0104,5835.851,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-25",6,4.66,336.29,,0.001,0.001,189.642,0.059,0.021,0.0133,3191.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-26",2,1.46,73.96,,0,0.001,45.618,0.059,0.009,0.0195,767.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-27",7,5.7,369.79,,0.001,0.001,213.832,0.059,0.02,0.0223,3599.371,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-28",5,4.2,326.08,,0.001,0.001,181.204,0.059,0.018,0.0114,3049.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-01",5,4.03,189.5,,0.001,0.001,121.904,0.0594,0.012,0.0196,2050.477,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-03",1,0.18,0.36,,0,0.001,1.584,0.06,0.001,0.107,26.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-03",6,2.96,116.64,,0,0.001,77.711,0.0595,0.013,0.0153,1308.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-04",7,5.58,342.78,,0.001,0.001,202.245,0.059,0.023,0.012,3404.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-05",10,8.35,574.72,,0.002,0.001,327.389,0.059,0.029,0.0124,5510.986,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-06",5,3.95,248.55,,0.001,0.001,144.775,0.059,0.013,0.0118,2435.451,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-08",3,1.72,100.3,,0,0.001,59.638,0.059,0.011,0.0177,1004.247,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-09",6,3.64,174.96,,0.001,0.001,111.362,0.0593,0.015,0.0278,1872.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-10",8,5.42,336.72,,0.001,0.001,197.529,0.0591,0.019,0.0219,3323.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-11",4,3.2,149.2,,0,0.001,96.15,0.0593,0.012,0.0143,1617.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-12",3,1.9,122.7,,0,0.001,71.39,0.059,0.015,0.0457,1201.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-13",13,11.23,957.75,,0.003,0.001,519.232,0.059,0.04,0.0159,8736.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-14",5,3.97,296,,0.001,0.001,165.855,0.0592,0.016,0.0114,2789.841,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-15",6,4.45,302.7,,0.001,0.001,173.455,0.0592,0.015,0.0223,2919.615,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-16",5,3.22,199.05,,0.001,0.001,116.808,0.0594,0.011,0.027,1964.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-17",3,1.45,100.4,,0,0.001,56.69,0.059,0.008,0.021,954.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-18",4,2.22,100.75,,0,0.001,65.365,0.059,0.009,0.0313,1100.377,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-19",3,1.45,84.2,,0,0.001,50.385,0.0593,0.008,0.0393,847.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-20",4,2.2,105.75,,0,0.001,67.59,0.059,0.009,0.0315,1136.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-21",3,2.22,100.94,,0,0.001,65.255,0.0593,0.009,0.017,1098.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-22",5,3.97,245.45,,0.001,0.001,144.657,0.0592,0.013,0.0126,2434.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-23",2,1.47,65.47,,0,0.001,42.324,0.059,0.007,0.021,712.393,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-24",11,7.66,412.45,,0.001,0.001,254.302,0.059,0.023,0.0168,4281.471,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-26",3,1.45,84.95,,0,0.001,50.87,0.059,0.009,0.041,855.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-28",2,1.45,64.65,,0,0.001,42.085,0.059,0.008,0.0235,707.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-29",6,4.45,257.2,,0.001,0.001,155.975,0.059,0.014,0.0152,2624.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-11-30",4,3.45,258.75,,0.001,0.001,145.365,0.059,0.014,0.015,2447.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-01",5,3.22,193.05,,0.001,0.001,115.797,0.0594,0.013,0.0276,1949.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-02",4,2.7,169.05,,0.001,0.001,100.36,0.059,0.013,0.0148,1689.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-03",7,5.45,261.6,,0.001,0.001,168.78,0.0593,0.015,0.0141,2840.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-04",8,5.4,330.7,,0.001,0.001,196.025,0.059,0.024,0.0224,3297.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-05",3,1.7,77.65,,0,0.001,50.085,0.0597,0.008,0.0403,841.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-06",9,7.2,381.7,,0.001,0.001,234.805,0.0591,0.02,0.0191,3951.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-09",3,1.45,64.35,,0,0.001,41.755,0.059,0.008,0.0427,703.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-10",4,2.7,140.85,,0,0.001,86.96,0.0593,0.01,0.015,1464.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-11",3,1.72,125.64,,0,0.001,70.296,0.059,0.008,0.0223,1183.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-12",6,2.61,215.23,,0.001,0.001,117.373,0.0593,0.015,0.0458,1975.867,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-13",4,2.65,119.6,,0,0.001,77.5,0.0593,0.011,0.0168,1304.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-14",6,4.17,246.94,,0.001,0.001,147.521,0.0592,0.02,0.0283,2482.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-15",7,5.7,343.15,,0.001,0.001,204.18,0.059,0.018,0.0119,3435.325,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-09",3,1.45,88.35,,0,0.001,51.815,0.0593,0.011,0.0413,871.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-10",1,0.6,39.6,,0,0.001,22.98,0.059,0.008,0.041,386.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-11",1,0.85,35.7,,0,0.001,23.885,0.06,0.001,0.006,401.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-13",3,1.45,66.2,,0,0.001,42.585,0.059,0.007,0.026,716.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-16",4,2.55,169.13,,0,0.001,97.837,0.059,0.012,0.017,1645.488,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-17",2,1.45,66.3,,0,0.001,42.795,0.0595,0.007,0.021,719.715,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-23",5,3.2,290,,0.001,0.001,156.06,0.059,0.024,0.0306,2625.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-25",4,2.92,163.96,,0.001,0.001,99.083,0.0593,0.015,0.02,1666.851,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-27",2,1.45,68.85,,0,0.001,43.96,0.059,0.007,0.022,739.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-29",5,2.92,153.77,,0,0.001,94.965,0.0592,0.015,0.0216,1598.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-03",5,2.9,142.06,,0,0.001,89.715,0.0592,0.017,0.0332,1508.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-04",6,4.17,333.02,,0.001,0.001,182.955,0.059,0.024,0.0193,3079.973,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-05",3,2.72,237.84,,0.001,0.001,127.732,0.059,0.017,0.016,2149.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-06",12,11.49,1103.43,,0.003,0.001,588.288,0.059,0.051,0.0106,9898.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-08",3,1.45,66.61,,0,0.001,42.843,0.059,0.007,0.0237,721.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-09",2,1.47,79.08,,0,0.001,47.903,0.0595,0.008,0.0225,805.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-11",5,3.95,342.55,,0.001,0.001,185.229,0.059,0.018,0.0134,3117.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-12",7,4.94,404.27,,0.001,0.001,220.369,0.0591,0.024,0.0253,3709.253,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-13",10,6.62,411,,0.001,0.001,241.865,0.0592,0.027,0.0175,4068.953,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-14",6,3.67,260.96,,0.001,0.001,147.552,0.059,0.018,0.0295,2483.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-15",2,1.47,104.67,,0,0.001,59.061,0.059,0.012,0.019,994.467,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-16",3,1.95,100.86,,0,0.001,62.726,0.059,0.008,0.022,1055.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-17",3,2.22,181.76,,0.001,0.001,99.25,0.059,0.014,0.0157,1670.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-18",3,2.2,170.52,,0,0.001,93.906,0.059,0.011,0.0173,1580.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-19",7,4.67,329.89,,0.001,0.001,186.307,0.0593,0.02,0.0197,3135.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-20",4,2.72,185.79,,0.001,0.001,106.87,0.059,0.01,0.018,1797.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-21",9,5.87,372.46,,0.001,0.001,216.904,0.0592,0.025,0.0183,3646.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-01",18,16.82,1284.61,,0.004,0.001,709.798,0.059,0.048,0.0092,11943.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-02",15,12.15,952.56,,0.003,0.001,522.349,0.0591,0.039,0.0147,8785.433,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-03",13,9.61,705.02,,0.002,0.001,394.051,0.0592,0.031,0.0149,6630.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-04",15,12.01,838.48,,0.002,0.001,476.46,0.0591,0.035,0.0103,8018.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-05",12,9.9,775.94,,0.002,0.001,429.007,0.059,0.032,0.016,7219.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-06",11,8.61,628.94,,0.002,0.001,356.597,0.059,0.033,0.0107,5999.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-07",8,5.65,409.34,,0.001,0.001,232.761,0.0591,0.022,0.0205,3916.779,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-08",8,7.15,625.63,,0.002,0.001,340.477,0.0591,0.033,0.0126,5729.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-09",14,12.42,1074.46,,0.003,0.001,587.42,0.059,0.045,0.01,9880.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-10",14,10.36,839.44,,0.002,0.001,466.152,0.0591,0.042,0.0208,7843.624,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-11",13,10.15,858.21,,0.002,0.001,475.406,0.0591,0.038,0.0157,8000.823,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-12",17,14.37,1205.26,,0.003,0.001,669.199,0.0591,0.049,0.0128,11259.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-13",7,6.2,526.84,,0.001,0.001,289.498,0.0591,0.023,0.01,4871.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-14",16,15.28,1030.77,,0.003,0.001,599.817,0.0591,0.037,0.0078,10089.281,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-15",13,10.49,800.75,,0.002,0.001,450.13,0.0591,0.036,0.0098,7573.831,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-16",11,7.86,622.75,,0.002,0.001,343.935,0.0592,0.032,0.0173,5786.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-17",8,5.65,331.54,,0.001,0.001,196.955,0.0591,0.02,0.0206,3314.187,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-18",6,4.2,353.92,,0.001,0.001,192.076,0.059,0.017,0.0232,3230.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-19",7,5.65,355.08,,0.001,0.001,208.735,0.0591,0.023,0.0134,3512.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-20",9,6.88,375.57,,0.001,0.001,230.869,0.0591,0.022,0.0203,3887.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-21",8,6.9,495.09,,0.001,0.001,283.627,0.059,0.027,0.0124,4770.157,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-22",6,5.45,347.24,,0.001,0.001,203.297,0.0592,0.016,0.0102,3421.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-23",9,6.9,328.87,,0.001,0.001,210.668,0.0591,0.022,0.0116,3543.299,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-24",5,3.65,189.42,,0.001,0.001,118.189,0.0592,0.017,0.0204,1987.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-25",5,4.45,269.47,,0.001,0.001,159.931,0.0592,0.015,0.0118,2689.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-26",5,4.7,306.73,,0.001,0.001,177.953,0.0592,0.016,0.0118,2993.907,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-27",16,13.18,1055.35,,0.003,0.001,585.895,0.0591,0.046,0.0143,9860.007,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-28",8,5.9,435.31,,0.001,0.001,245.354,0.059,0.026,0.0208,4129.363,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-29",5,3.7,311.4,,0.001,0.001,168.666,0.0592,0.015,0.0246,2838.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-30",10,6.9,460.64,,0.001,0.001,263.244,0.059,0.025,0.0184,4432.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-03-31",8,6.15,321.55,,0.001,0.001,197.137,0.059,0.019,0.0125,3318.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-01",5,3.43,313.96,,0.001,0.001,167.973,0.0592,0.016,0.0258,2827.458,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-02",4,3.2,274.62,,0.001,0.001,150.572,0.059,0.015,0.014,2532.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-03",10,7.03,585.76,,0.002,0.001,320.25,0.059,0.033,0.0251,5390.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-04",15,11.12,1028.56,,0.003,0.001,550.932,0.0591,0.043,0.0177,9269.889,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-05",6,4.28,316.37,,0.001,0.001,177.205,0.059,0.015,0.0137,2981.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-06",8,5.63,340.35,,0.001,0.001,200.929,0.0591,0.021,0.0205,3379.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-07",8,5.36,287.18,,0.001,0.001,175.12,0.0593,0.021,0.0224,2946.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-08",8,6.67,414.45,,0.001,0.001,243.492,0.059,0.025,0.0214,4098.031,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-09",10,7.03,471.88,,0.001,0.001,271.834,0.0593,0.029,0.0192,4571.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-10",6,4.28,271.23,,0.001,0.001,157.937,0.0592,0.012,0.0205,2656.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-11",5,3.2,257.08,,0.001,0.001,140.376,0.0592,0.014,0.0268,2362.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-12",5,4.2,328.05,,0.001,0.001,180.84,0.0592,0.015,0.0114,3042.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-13",4,2.95,220.66,,0.001,0.001,122.84,0.0593,0.013,0.0303,2066.163,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-14",7,5.68,445.5,,0.001,0.001,248.76,0.0591,0.021,0.0223,4186.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-15",4,2.95,244.45,,0.001,0.001,134.225,0.059,0.013,0.0295,2257.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-16",7,4.66,360.84,,0.001,0.001,201.155,0.059,0.019,0.022,3384.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-17",9,6.41,468.93,,0.001,0.001,265.268,0.0591,0.023,0.0182,4462.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-18",10,6.9,515.1,,0.001,0.001,289.556,0.0591,0.029,0.0195,4872.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-19",7,3.92,315.36,,0.001,0.001,172.403,0.0593,0.018,0.0317,2900.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-21",6,4.58,302.46,,0.001,0.001,176.079,0.0592,0.019,0.0132,2962.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-22",7,4.78,354.28,,0.001,0.001,201.672,0.0596,0.018,0.01,3391.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-23",4,2.7,240.05,,0.001,0.001,130.691,0.059,0.014,0.017,2200.071,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-24",7,6.18,433.66,,0.001,0.001,251.873,0.0591,0.023,0.0157,4237.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-25",5,3.95,334.26,,0.001,0.001,185.109,0.059,0.016,0.0116,3114.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-26",4,2.45,219.21,,0.001,0.001,120.363,0.059,0.014,0.032,2024.851,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-27",3,2.45,147.04,,0,0.001,88.262,0.059,0.012,0.0147,1485.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-28",5,4.7,419.58,,0.001,0.001,230.21,0.059,0.022,0.0124,3874.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-29",5,3.39,187.92,,0.001,0.001,115.029,0.059,0.016,0.0164,1936.537,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-04-30",9,6.9,350.7,,0.001,0.001,221.242,0.0591,0.022,0.0199,3722.982,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-01",5,3.97,209.5,,0.001,0.001,130.145,0.059,0.013,0.0116,2191.459,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-02",6,5.45,297.86,,0.001,0.001,183.084,0.059,0.017,0.0115,3079.717,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-03",7,5.93,388.35,,0.001,0.001,226.717,0.059,0.022,0.0111,3815.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-04",6,4.95,349.24,,0.001,0.001,199.606,0.059,0.018,0.0117,3358.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-05",4,3.45,254.62,,0.001,0.001,144.219,0.0593,0.015,0.0115,2427.363,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-06",5,3.95,234.42,,0.001,0.001,140.338,0.059,0.013,0.0242,2361.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-07",5,3.7,240.92,,0.001,0.001,140.388,0.0594,0.011,0.0252,2362.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-08",7,5.08,342.22,,0.001,0.001,197.002,0.0591,0.018,0.0216,3315.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-09",8,6.28,418.1,,0.001,0.001,242.136,0.0591,0.018,0.0183,4074.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-10",9,6.65,433.26,,0.001,0.001,251.542,0.0591,0.021,0.0176,4234.037,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-11",6,3.66,196.44,,0.001,0.001,119.662,0.0592,0.013,0.025,2013.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-12",4,2.7,168.42,,0,0.001,98.606,0.059,0.01,0.0303,1660.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-14",3,1.45,83.89,,0,0.001,49.55,0.059,0.007,0.0383,834.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-15",3,1.88,157.79,,0,0.001,86.337,0.0593,0.012,0.0327,1451.682,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-16",6,4.68,453.22,,0.001,0.001,242.542,0.0592,0.022,0.0237,4082.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-17",2,1.14,95.12,,0,0.001,52.08,0.059,0.011,0.0245,875.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-22",6,4.2,309.48,,0.001,0.001,175.896,0.0592,0.012,0.019,2960.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-23",3,2.45,220.9,,0.001,0.001,119.479,0.059,0.016,0.0157,2010.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-24",2,1.55,81.59,,0,0.001,50.577,0.06,0.009,0.0175,849.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-25",4,3.2,305.56,,0.001,0.001,165.018,0.059,0.017,0.0135,2778.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-26",4,3.45,280.43,,0.001,0.001,156.471,0.059,0.016,0.0133,2632.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-27",4,3.2,253.4,,0.001,0.001,142.704,0.059,0.014,0.0125,2402.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-28",2,1.43,96.65,,0,0.001,55.978,0.0595,0.011,0.018,941.887,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-30",5,3.2,192.72,,0.001,0.001,115.392,0.0592,0.012,0.0266,1942.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-05-31",3,1.7,97.04,,0,0.001,58.452,0.059,0.008,0.0373,983.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-05",3,1.45,63.95,,0,0.001,41.423,0.0593,0.006,0.036,696.531,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-08",3,1.45,70.27,,0,0.001,44.384,0.059,0.006,0.0403,746.501,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-09",5,3.16,151.36,,0,0.001,97.248,0.0592,0.01,0.0284,1636.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-12",7,6.12,310.12,,0.001,0.001,195.736,0.0591,0.016,0.021,3294.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-13",4,2.03,168.81,,0,0.001,92.989,0.0593,0.012,0.014,1564.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-14",4,2.2,199.6,,0.001,0.001,107.944,0.059,0.013,0.028,1817.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-15",2,1.43,118.3,,0,0.001,65.048,0.059,0.012,0.0185,1094.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-16",8,5.67,402,,0.001,0.001,230.81,0.059,0.025,0.0206,3885.419,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-17",2,1.68,89.89,,0,0.001,55.614,0.059,0.009,0.019,936.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-18",2,1.45,103.74,,0,0.001,59.516,0.059,0.01,0.0195,1002.018,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-19",3,2.2,201.85,,0.001,0.001,110.24,0.059,0.016,0.015,1854.607,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-20",4,2.43,213.39,,0.001,0.001,116.929,0.0593,0.014,0.0305,1967.969,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-21",3,1.95,160.78,,0,0.001,89.343,0.0593,0.01,0.015,1503.061,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-22",4,2.96,259.25,,0.001,0.001,141.583,0.059,0.014,0.0133,2382.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-23",11,8.38,756.05,,0.002,0.001,411.35,0.0591,0.044,0.0192,6919.963,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-24",4,3.2,292.84,,0.001,0.001,159.662,0.059,0.02,0.0138,2687.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-26",4,3.71,345.45,,0.001,0.001,186.66,0.059,0.022,0.0143,3142.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-27",9,6.91,605.42,,0.002,0.001,331.723,0.0591,0.029,0.0137,5582.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-28",3,1.95,179.65,,0,0.001,96.588,0.0593,0.016,0.015,1625.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-29",4,2.93,262.32,,0.001,0.001,142.839,0.0593,0.014,0.0185,2402.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-06-30",4,2.7,246.92,,0.001,0.001,133.861,0.059,0.015,0.014,2251.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-01",4,2.96,278.19,,0.001,0.001,150.309,0.0593,0.016,0.0318,2530.986,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-02",4,3.16,283.78,,0.001,0.001,153.368,0.059,0.015,0.014,2579.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-03",7,5.2,439.84,,0.001,0.001,242.964,0.0591,0.021,0.0207,4088.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-04",4,3.21,290.42,,0.001,0.001,157.64,0.059,0.015,0.013,2653.844,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-05",9,8.46,707.42,,0.002,0.001,391.19,0.059,0.031,0.0103,6581.813,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-06",6,4.7,425.94,,0.001,0.001,232.598,0.0592,0.02,0.0242,3913.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-07",4,3.15,280.21,,0.001,0.001,152.727,0.059,0.014,0.0133,2569.837,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-08",2,1.41,122.17,,0,0.001,66.642,0.059,0.01,0.02,1121.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-09",4,3.7,306.53,,0.001,0.001,170.497,0.059,0.019,0.0128,2868.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-10",7,6.7,622.37,,0.002,0.001,337.426,0.059,0.031,0.0113,5677.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-11",7,6.4,579.46,,0.002,0.001,316.047,0.059,0.024,0.011,5317.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-12",6,5.45,501.53,,0.001,0.001,272.025,0.059,0.025,0.0118,4579.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-13",3,2.45,187.25,,0.001,0.001,104.605,0.059,0.012,0.0153,1760.043,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-14",3,1.7,107.95,,0,0.001,62.766,0.0593,0.007,0.021,1056.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-15",4,2.2,186.32,,0.001,0.001,101.096,0.0593,0.012,0.0293,1701.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-16",3,1.45,102.76,,0,0.001,57.915,0.059,0.008,0.0357,975.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-17",9,7.43,431.07,,0.001,0.001,260.24,0.059,0.017,0.0156,4378.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-18",4,2.45,134.39,,0,0.001,81.987,0.0593,0.009,0.0303,1380.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-19",4,2.2,135.72,,0,0.001,79.828,0.059,0.008,0.0285,1343.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-20",5,3.16,169.2,,0.001,0.001,103.984,0.059,0.011,0.0248,1750.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-21",4,2.77,189.79,,0.001,0.001,108.818,0.059,0.016,0.0143,1830.757,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-22",3,2.7,208.6,,0.001,0.001,116.188,0.059,0.014,0.0143,1954.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-23",3,1.7,131.22,,0,0.001,72.852,0.0593,0.01,0.016,1226.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-24",4,2.95,250.6,,0.001,0.001,137.581,0.059,0.015,0.0128,2314.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-25",4,2.4,198.37,,0.001,0.001,108.921,0.059,0.012,0.032,1832.417,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-26",5,3.7,316.62,,0.001,0.001,172.742,0.059,0.014,0.0254,2907.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-27",7,6.08,439.26,,0.001,0.001,249.108,0.059,0.02,0.0111,4191.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-28",4,2.95,248.32,,0.001,0.001,135.675,0.059,0.013,0.0128,2282.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-29",4,2.95,234.11,,0.001,0.001,130.28,0.059,0.012,0.0168,2193.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-30",5,4.43,381.68,,0.001,0.001,207.929,0.059,0.017,0.0116,3498.931,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-07-31",6,5.19,422.43,,0.001,0.001,233.987,0.059,0.019,0.0137,3936.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-03",5,3.85,195.59,,0.001,0.001,123.245,0.0592,0.014,0.0126,2071.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-13",5,4.45,294.79,,0.001,0.001,170.872,0.059,0.014,0.0104,2875.069,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-14",9,7.45,617.84,,0.002,0.001,340.249,0.059,0.023,0.0167,5726.169,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-15",4,3.71,188.13,,0.001,0.001,118.195,0.0593,0.011,0.0105,1988.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-17",8,7.49,663.88,,0.002,0.001,359.913,0.059,0.028,0.01,6054.561,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-18",12,10.71,742.57,,0.002,0.001,429.381,0.0591,0.026,0.0136,7223.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-19",7,6.45,480.7,,0.001,0.001,272.779,0.0591,0.02,0.0097,4586.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-20",9,7.21,426.64,,0.001,0.001,257.209,0.059,0.018,0.0169,4329.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-21",7,5.21,422.9,,0.001,0.001,234.526,0.059,0.019,0.0206,3945.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-22",5,3.41,204.56,,0.001,0.001,122.088,0.059,0.015,0.0132,2052.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-23",4,3.21,272.12,,0.001,0.001,149.126,0.059,0.015,0.0138,2508.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-24",8,7.71,628.82,,0.002,0.001,347.233,0.059,0.027,0.0096,5842.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-26",2,1.46,70.44,,0,0.001,44.442,0.059,0.008,0.0185,748.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-27",9,7.7,590.8,,0.002,0.001,329.848,0.059,0.025,0.018,5549.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-28",5,3.42,170,,0.001,0.001,107.378,0.059,0.009,0.0154,1808.059,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-01",5,4.03,187,,0.001,0.001,121.803,0.0592,0.012,0.0192,2048.821,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-21",5,2.42,168.16,,0,0.001,95.537,0.0592,0.015,0.0362,1607.027,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-24",4,3.45,266.08,,0.001,0.001,148.983,0.059,0.016,0.0125,2508.229,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-25",4,2.95,201.61,,0.001,0.001,115.857,0.059,0.012,0.03,1949.678,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-26",4,2.2,171.9,,0,0.001,95.863,0.059,0.011,0.0345,1613.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-27",4,2.95,246.5,,0.001,0.001,135.814,0.059,0.014,0.013,2284.439,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-29",3,1.45,106.19,,0,0.001,60.408,0.0593,0.01,0.0387,1016.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-10-31",8,6.1,420.98,,0.001,0.001,241.551,0.0593,0.021,0.0218,4062.439,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-01",5,3.02,236.41,,0.001,0.001,131.352,0.059,0.013,0.0166,2211.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-02",2,0.48,20.52,,0,0.001,13.29,0.059,0.011,0.113,223.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-03",3,1.95,89.85,,0,0.001,58.385,0.059,0.008,0.022,982.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-04",4,2.7,161.98,,0,0.001,96.988,0.0593,0.01,0.0133,1630.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-05",5,3.95,332.25,,0.001,0.001,181.33,0.0592,0.015,0.0152,3050.729,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-06",4,2.7,130.76,,0,0.001,82.941,0.0595,0.009,0.0143,1394.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-09",4,2.45,158.28,,0,0.001,92.445,0.0593,0.01,0.02,1554.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-10",8,4.9,307.3,,0.001,0.001,180.645,0.0593,0.017,0.031,3039.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-11",7,4.17,275.84,,0.001,0.001,159.629,0.0593,0.015,0.0227,2685.323,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-12",4,2.47,196,,0.001,0.001,108.245,0.059,0.011,0.0175,1821.394,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-13",3,1.47,75,,0,0.001,46.625,0.0593,0.007,0.0207,785.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-14",4,2.45,189.38,,0.001,0.001,104.747,0.0593,0.01,0.0185,1763.173,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-15",5,3.2,234.94,,0.001,0.001,132.066,0.0592,0.012,0.0268,2224.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-16",5,3.22,240.35,,0.001,0.001,133.998,0.059,0.012,0.0272,2254.669,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-17",4,2.2,148.65,,0,0.001,85.445,0.0593,0.009,0.0303,1438.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-19",4,2.22,119.2,,0,0.001,73.42,0.0593,0.01,0.0325,1234.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-20",3,1.7,96,,0,0.001,57.83,0.059,0.009,0.0207,973.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-21",4,2.95,139.05,,0,0.001,89.785,0.0593,0.011,0.0148,1509.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-22",5,3.22,168.35,,0.001,0.001,105.065,0.0592,0.012,0.0272,1768.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-23",3,1.97,89.13,,0,0.001,58.226,0.0593,0.008,0.017,979.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-24",7,5.47,310.53,,0.001,0.001,189.608,0.059,0.014,0.0199,3192.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-25",6,4.22,227.75,,0.001,0.001,141.04,0.0592,0.014,0.0247,2371.978,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-27",2,1.45,64.65,,0,0.001,42.745,0.0595,0.008,0.0235,718.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-28",4,2.95,138.2,,0,0.001,89.695,0.0593,0.012,0.0143,1509.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-29",5,3.47,204.97,,0.001,0.001,123.498,0.0592,0.013,0.037,2076.867,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-11-30",3,2.45,112.65,,0,0.001,73.62,0.0593,0.009,0.017,1238.52,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-01",10,7.17,411.84,,0.001,0.001,251.901,0.059,0.02,0.0186,4239.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-03",4,2.45,118.95,,0,0.001,76.19,0.059,0.011,0.0343,1282.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-04",6,3.85,264.57,,0.001,0.001,151.992,0.059,0.021,0.0267,2557.885,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-07",3,1.47,64.2,,0,0.001,42.205,0.0597,0.007,0.0233,709.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-08",3,1.45,95,,0,0.001,54.515,0.059,0.009,0.0407,917.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-09",3,1.47,101.88,,0,0.001,57.424,0.059,0.009,0.0373,966.574,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-10",3,1.45,79.2,,0,0.001,48.01,0.0593,0.007,0.021,807.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-11",2,1.45,66.65,,0,0.001,42.97,0.059,0.008,0.019,723.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-12",8,6.7,379.05,,0.001,0.001,229.5,0.0593,0.021,0.0106,3859.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-13",3,1.95,88.2,,0,0.001,57.8,0.0593,0.01,0.0163,972.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-15",6,4.63,280.56,,0.001,0.001,166.887,0.0592,0.021,0.0155,2806.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-16",10,7.86,595.47,,0.002,0.001,333.608,0.059,0.03,0.0114,5615.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-18",4,2.2,176.85,,0,0.001,97.565,0.0593,0.012,0.032,1641.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-19",6,4.95,272.5,,0.001,0.001,168.69,0.0592,0.016,0.0103,2840.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-15",3,1.45,65.85,,0,0.001,41.96,0.059,0.006,0.023,706.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-21",3,1.68,111.84,,0,0.001,63.756,0.059,0.009,0.0397,1073.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-23",5,3.2,289.4,,0.001,0.001,153.78,0.059,0.019,0.0314,2588.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-25",9,5.37,320.98,,0.001,0.001,189.056,0.0591,0.024,0.0308,3180.159,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-27",3,1.45,66.2,,0,0.001,42.37,0.059,0.007,0.023,713.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-28",3,1.45,67.2,,0,0.001,42.75,0.059,0.006,0.0223,719.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-29",6,3.67,229.65,,0.001,0.001,133.83,0.0592,0.018,0.0223,2252.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-01",2,1.47,66.08,,0,0.001,42.347,0.059,0.007,0.02,712.843,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-03",5,2.92,142.08,,0,0.001,88.398,0.0592,0.016,0.0334,1487.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-04",10,6.64,553.74,,0.002,0.001,304.737,0.0593,0.035,0.0171,5125.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-05",10,6.39,520.39,,0.001,0.001,283.315,0.0591,0.031,0.0289,4768.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-06",3,1.97,160.1,,0,0.001,87.51,0.059,0.01,0.023,1472.803,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-07",6,3.17,187.39,,0.001,0.001,110.861,0.059,0.016,0.0305,1866.236,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-08",7,4.92,234.64,,0.001,0.001,147.367,0.0591,0.016,0.0166,2480.383,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-09",3,2.47,137.38,,0,0.001,82.322,0.059,0.011,0.015,1384.921,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-11",9,7.13,521.49,,0.001,0.001,291.42,0.059,0.026,0.0153,4903.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-12",9,6.69,570.14,,0.002,0.001,307.853,0.059,0.027,0.017,5180.509,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-13",9,7.67,507.36,,0.001,0.001,291.449,0.059,0.023,0.0118,4902.991,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-14",10,8.44,646.02,,0.002,0.001,357.178,0.059,0.032,0.0122,6009.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-15",2,1.47,94.11,,0,0.001,54.615,0.059,0.009,0.02,919.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-16",4,2.95,153.93,,0,0.001,95.444,0.0593,0.01,0.014,1604.577,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-17",6,4.97,464.42,,0.001,0.001,247.758,0.059,0.022,0.0152,4166.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-18",8,5.42,370.39,,0.001,0.001,209.195,0.0591,0.021,0.0254,3518.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-19",9,7.69,615.76,,0.002,0.001,335.94,0.059,0.031,0.0143,5653.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-20",7,5.19,314.36,,0.001,0.001,184.372,0.059,0.018,0.014,3104.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-21",7,5.69,384.8,,0.001,0.001,219.557,0.059,0.024,0.0136,3694.839,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-23",7,5.97,452.5,,0.001,0.001,249.507,0.0591,0.02,0.0106,4197.189,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-24",5,3.95,333.72,,0.001,0.001,181.324,0.059,0.018,0.0126,3051.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-25",6,4.4,265.76,,0.001,0.001,156.143,0.059,0.02,0.0152,2627.201,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-26",9,7.92,571.33,,0.002,0.001,320.392,0.059,0.03,0.0121,5390.534,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-27",7,4.94,340.65,,0.001,0.001,193.39,0.0591,0.021,0.0241,3252.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-28",4,2.95,174.76,,0.001,0.001,103.427,0.0593,0.012,0.013,1739.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-02-29",4,3.22,242.15,,0.001,0.001,133.766,0.059,0.014,0.0133,2251.473,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-01",8,7.87,594.37,,0.002,0.001,326.444,0.0591,0.022,0.0088,5492.141,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-02",10,6.73,517.03,,0.001,0.001,282.444,0.059,0.027,0.0204,4750.823,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-03",4,2.95,140.02,,0,0.001,88.022,0.0593,0.011,0.014,1481.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-04",8,6.15,418.03,,0.001,0.001,237.63,0.0591,0.023,0.0125,3999.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-05",10,8.15,499.23,,0.001,0.001,290.842,0.059,0.026,0.0194,4895.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-06",8,6.42,425.58,,0.001,0.001,243.762,0.0591,0.026,0.0121,4100.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-07",6,4.65,318.46,,0.001,0.001,180.576,0.059,0.02,0.0137,3039.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-08",10,7.92,686.6,,0.002,0.001,369.214,0.0593,0.033,0.0139,6212.185,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-09",11,9.15,740.98,,0.002,0.001,404.464,0.059,0.034,0.0106,6806.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-10",10,8.15,771.22,,0.002,0.001,407.459,0.0592,0.036,0.0192,6855.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-11",10,7.65,713.87,,0.002,0.001,380.832,0.0591,0.035,0.0201,6407.721,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-12",18,17.14,1227.88,,0.004,0.001,695.335,0.0591,0.048,0.0086,11699.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-13",6,5.45,478.19,,0.001,0.001,256.706,0.059,0.022,0.011,4317.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-14",18,16.16,1041.03,,0.003,0.001,605.149,0.0591,0.043,0.0085,10180.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-15",13,9.61,717.35,,0.002,0.001,398.01,0.059,0.036,0.0175,6697.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-16",12,8.87,714.58,,0.002,0.001,386.772,0.0592,0.035,0.0174,6507.669,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-17",13,9.62,678.54,,0.002,0.001,379.976,0.059,0.033,0.017,6392.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-18",8,5.4,320.04,,0.001,0.001,187.928,0.0593,0.02,0.0253,3161.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-19",6,4.67,310.81,,0.001,0.001,176.799,0.059,0.021,0.0138,2974.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-20",7,5.4,281.38,,0.001,0.001,173.179,0.0594,0.019,0.0139,2913.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-21",9,7.4,460.79,,0.001,0.001,269.517,0.0591,0.024,0.0198,4534.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-22",10,6.83,343.94,,0.001,0.001,213.92,0.0592,0.024,0.0153,3600.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-23",5,3.41,158.82,,0.001,0.001,100.735,0.0594,0.014,0.014,1693.549,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-24",8,6.15,321.31,,0.001,0.001,198.714,0.059,0.019,0.0204,3345.727,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-25",5,3.95,217.37,,0.001,0.001,130.91,0.059,0.014,0.0126,2202.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-26",6,5.7,310.96,,0.001,0.001,187.314,0.059,0.017,0.0113,3153.169,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-27",10,7.41,393.7,,0.001,0.001,241.738,0.0593,0.024,0.0195,4069.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-28",8,6.4,494.81,,0.001,0.001,271.533,0.059,0.026,0.0154,4568.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-29",5,3.2,261.84,,0.001,0.001,141.856,0.0592,0.014,0.0266,2386.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-30",9,6.65,410.2,,0.001,0.001,236.821,0.059,0.023,0.0232,3984.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-03-31",8,5.65,307.58,,0.001,0.001,184.71,0.0593,0.02,0.0153,3107.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-01",8,5.65,415.02,,0.001,0.001,229.86,0.0591,0.022,0.0241,3866.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-02",8,5.65,427.64,,0.001,0.001,236.197,0.059,0.023,0.0226,3974.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-03",11,7.8,663.56,,0.002,0.001,357.234,0.059,0.034,0.0201,6011.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-04",11,9.41,915.45,,0.002,0.001,478.357,0.059,0.04,0.0104,8050.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-05",5,2.78,203.3,,0.001,0.001,112.242,0.0592,0.011,0.025,1889.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-06",5,3.15,147.93,,0,0.001,93.216,0.059,0.013,0.029,1569.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-07",7,4.65,258.73,,0.001,0.001,153.913,0.0594,0.017,0.0256,2588.972,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-08",10,7.4,595.92,,0.002,0.001,323.278,0.0593,0.029,0.026,5439.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-09",9,6.4,445.64,,0.001,0.001,250.605,0.0593,0.024,0.0189,4215.365,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-10",4,2.95,168.76,,0.001,0.001,100.244,0.059,0.01,0.0303,1688.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-11",5,3.95,329.25,,0.001,0.001,175.88,0.059,0.017,0.0116,2959.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-12",7,5.2,355.6,,0.001,0.001,199.36,0.0591,0.015,0.0204,3354.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-13",7,4.41,329.8,,0.001,0.001,180.747,0.059,0.018,0.0317,3042.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-14",11,8.4,649.38,,0.002,0.001,358.322,0.0591,0.029,0.0168,6027.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-15",6,4.16,269.24,,0.001,0.001,155.625,0.059,0.019,0.0178,2618.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-16",11,7.86,581.94,,0.002,0.001,323.901,0.0592,0.034,0.0189,5449.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-17",5,4.2,382.86,,0.001,0.001,203.068,0.059,0.018,0.0118,3418.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-18",7,5.15,446.06,,0.001,0.001,239.595,0.0591,0.026,0.0226,4031.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-19",7,5.95,431.11,,0.001,0.001,240.58,0.0591,0.018,0.0104,4049.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-21",5,3.58,285.63,,0.001,0.001,156.694,0.059,0.021,0.015,2637.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-22",13,10.28,563.52,,0.002,0.001,343.504,0.0592,0.024,0.0143,5778.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-23",4,2.66,206.48,,0.001,0.001,114.7,0.059,0.012,0.0165,1929.932,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-24",5,4.45,391.46,,0.001,0.001,209.943,0.059,0.018,0.0106,3531.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-25",6,4.95,410.11,,0.001,0.001,224.305,0.059,0.018,0.0107,3773.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-26",3,2.2,206.53,,0.001,0.001,109.772,0.059,0.015,0.0143,1847.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-27",4,3.46,212.88,,0.001,0.001,125.076,0.059,0.013,0.0125,2105.994,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-28",4,3.7,354.16,,0.001,0.001,189.126,0.059,0.021,0.0133,3181.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-29",9,6.11,296.15,,0.001,0.001,187.819,0.0592,0.019,0.0201,3159.177,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-04-30",8,6.15,296.68,,0.001,0.001,187.019,0.0591,0.019,0.0204,3148.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-01",5,3.97,215.5,,0.001,0.001,130.697,0.0592,0.012,0.0116,2199.877,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-02",6,5.2,301.39,,0.001,0.001,179.746,0.059,0.016,0.0108,3023.657,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-03",5,4.2,240.68,,0.001,0.001,144.141,0.0594,0.014,0.012,2425.773,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-04",11,8.04,559.66,,0.002,0.001,316.958,0.059,0.029,0.0197,5335.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-05",7,4.53,298.94,,0.001,0.001,171.406,0.0593,0.014,0.021,2883.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-06",3,1.95,103.94,,0,0.001,62.717,0.059,0.009,0.0153,1055.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-07",5,3.95,271.01,,0.001,0.001,153.611,0.0592,0.014,0.0262,2585.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-08",5,4.22,297.24,,0.001,0.001,167.64,0.059,0.015,0.0106,2819.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-09",6,5.45,419.27,,0.001,0.001,230.422,0.059,0.02,0.011,3877.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-10",6,5.87,429.82,,0.001,0.001,240.194,0.059,0.022,0.0107,4041.06,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-11",7,3.74,190.17,,0.001,0.001,115.916,0.059,0.014,0.0336,1951.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-12",5,3.41,234.39,,0.001,0.001,131.614,0.059,0.016,0.014,2214.951,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-13",6,5.87,386.39,,0.001,0.001,221.722,0.0592,0.022,0.011,3730.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-14",6,3.8,194.24,,0.001,0.001,119.46,0.0593,0.011,0.0223,2008.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-15",3,2.7,236.19,,0.001,0.001,126.36,0.059,0.015,0.015,2126.017,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-16",6,4.95,438.15,,0.001,0.001,234.948,0.0592,0.022,0.0145,3951.797,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-17",3,1.95,183.52,,0,0.001,96.893,0.059,0.014,0.0143,1630.661,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-19",5,3.45,178.5,,0.001,0.001,109.651,0.059,0.01,0.0162,1846.361,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-21",5,3.45,277.31,,0.001,0.001,151.119,0.0592,0.014,0.028,2543.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-22",7,6.37,350.5,,0.001,0.001,213.196,0.0593,0.016,0.013,3585.467,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-23",10,8.53,527.18,,0.002,0.001,309.035,0.0592,0.025,0.009,5200.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-24",2,1.45,71.34,,0,0.001,44.428,0.059,0.008,0.0175,747.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-25",4,3.2,311.28,,0.001,0.001,164.608,0.059,0.017,0.0135,2769.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-26",4,3.7,306.41,,0.001,0.001,167.701,0.059,0.018,0.0125,2822.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-27",3,2.2,182.74,,0.001,0.001,100.18,0.059,0.012,0.0147,1685.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-28",3,1.45,123.12,,0,0.001,66.895,0.059,0.009,0.0197,1125.501,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-30",9,7.2,405.12,,0.001,0.001,243.828,0.0591,0.015,0.0169,4102.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-05-31",4,2.95,179.92,,0.001,0.001,105.535,0.0593,0.01,0.0315,1775.163,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-03",3,1.45,65.15,,0,0.001,41.58,0.0593,0.007,0.0393,699.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-07",4,2.2,158.04,,0,0.001,88.14,0.059,0.012,0.031,1482.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-08",4,2.95,202.96,,0.001,0.001,115.343,0.0593,0.012,0.0345,1940.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-13",3,2.2,196.72,,0.001,0.001,105.12,0.059,0.013,0.0147,1768.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-14",4,2.95,278.05,,0.001,0.001,146.892,0.059,0.016,0.0305,2473.323,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-15",2,1.7,154.03,,0,0.001,82.19,0.059,0.013,0.0185,1382.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-16",3,2.45,233.76,,0.001,0.001,123.646,0.059,0.016,0.0147,2079.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-17",3,1.95,98.47,,0,0.001,61.589,0.0597,0.008,0.0153,1035.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-18",2,1.45,108.71,,0,0.001,60.344,0.059,0.01,0.0195,1016.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-19",4,2.7,253.19,,0.001,0.001,135.121,0.0593,0.014,0.0168,2274.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-20",4,2.2,198.04,,0.001,0.001,106.196,0.0593,0.013,0.0323,1787.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-21",2,1.72,153.2,,0,0.001,82.013,0.059,0.014,0.019,1379.854,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-22",3,2.45,214.72,,0.001,0.001,115.449,0.059,0.013,0.0157,1942.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-23",3,2.46,225.13,,0.001,0.001,120.046,0.059,0.014,0.016,2019.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-24",10,6.92,617.75,,0.002,0.001,330.452,0.059,0.037,0.0218,5560.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-26",4,3.7,344.32,,0.001,0.001,181.934,0.059,0.019,0.0128,3062.201,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-27",6,4.66,410.32,,0.001,0.001,220.102,0.059,0.026,0.0135,3701.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-28",3,1.95,180.52,,0,0.001,95.532,0.059,0.015,0.014,1608.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-29",3,2.45,214.78,,0.001,0.001,115.029,0.059,0.015,0.0147,1936.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-06-30",4,2.95,276.84,,0.001,0.001,146.514,0.0593,0.018,0.0128,2466.241,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-01",4,2.46,223.96,,0.001,0.001,119.271,0.059,0.013,0.03,2006.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-02",4,3.45,317.1,,0.001,0.001,168.083,0.059,0.018,0.013,2828.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-03",5,3.7,358.64,,0.001,0.001,190.118,0.059,0.02,0.0284,3197.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-04",7,4.67,351.74,,0.001,0.001,195.382,0.059,0.02,0.021,3287.556,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-05",7,5.96,466.71,,0.001,0.001,258.365,0.059,0.022,0.022,4346.647,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-06",6,4.7,422.36,,0.001,0.001,225.486,0.0592,0.019,0.024,3793.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-07",4,3.2,289.66,,0.001,0.001,154.47,0.059,0.015,0.013,2597.472,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-08",3,2.2,198.14,,0.001,0.001,105.516,0.059,0.012,0.0147,1775.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-09",4,3.2,274.86,,0.001,0.001,147.222,0.059,0.017,0.0128,2476.429,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-10",6,4.95,449.04,,0.001,0.001,237.714,0.059,0.021,0.0142,3999.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-11",7,6.7,618.39,,0.002,0.001,330.248,0.059,0.029,0.0106,5556.519,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-12",6,3.66,283.24,,0.001,0.001,155.753,0.059,0.018,0.026,2619.972,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-13",3,1.95,147.43,,0,0.001,81.006,0.059,0.009,0.0197,1363.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-16",5,3.2,274.24,,0.001,0.001,146.48,0.0592,0.014,0.0266,2464.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-17",5,3.45,233.78,,0.001,0.001,132.416,0.059,0.012,0.0262,2228.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-18",5,3.2,205,,0.001,0.001,118.732,0.0592,0.011,0.0262,1998.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-19",5,3.2,195.12,,0.001,0.001,114.68,0.059,0.011,0.0298,1929.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-20",5,3.2,171.12,,0.001,0.001,104.88,0.0592,0.01,0.0262,1764.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-21",5,3.2,268,,0.001,0.001,145.42,0.059,0.013,0.0272,2447.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-22",4,2.95,198.72,,0.001,0.001,113.188,0.059,0.011,0.0305,1904.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-23",4,2.2,136.88,,0,0.001,79.048,0.0595,0.008,0.0313,1329.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-24",4,2.2,184.6,,0.001,0.001,99.036,0.0593,0.011,0.031,1666.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-25",4,2.45,203.02,,0.001,0.001,109.278,0.0593,0.012,0.0315,1839.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-26",5,3.45,295.06,,0.001,0.001,158.317,0.059,0.014,0.0266,2663.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-27",5,3.45,302.75,,0.001,0.001,161.279,0.059,0.016,0.0268,2714.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-30",8,7.1,378.4,,0.001,0.001,232.76,0.0591,0.019,0.0198,3915.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-07-31",8,5.53,270.76,,0.001,0.001,171.095,0.059,0.014,0.0131,2879.967,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-13",3,2.21,165.61,,0,0.001,91.027,0.059,0.011,0.0153,1530.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-14",7,6.33,536.2,,0.001,0.001,288.98,0.059,0.023,0.009,4863.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-15",4,3.71,192.53,,0.001,0.001,118.649,0.0598,0.013,0.0125,1994.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-17",8,7.49,663.54,,0.002,0.001,355.392,0.059,0.028,0.0099,5981.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-18",13,11.97,1083.77,,0.003,0.001,583.964,0.0591,0.041,0.0098,9828.633,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-19",7,6.45,513.54,,0.001,0.001,283.58,0.059,0.022,0.01,4772.071,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-20",11,9.71,648.18,,0.002,0.001,373.313,0.059,0.024,0.0078,6281.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-21",6,4.21,336.42,,0.001,0.001,183.982,0.0592,0.016,0.0218,3097.721,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-24",8,7.38,373.86,,0.001,0.001,233.234,0.0591,0.017,0.0119,3926.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-25",10,9.07,449,,0.001,0.001,280.818,0.0593,0.017,0.0074,4725.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-28",5,3.42,176.15,,0.001,0.001,108.768,0.0592,0.011,0.0162,1831.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-01",5,4.03,190.73,,0.001,0.001,121.7,0.0592,0.011,0.0178,2047.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-03",2,0.96,63.58,,0,0.001,36.365,0.059,0.007,0.058,612.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-24",5,3.09,213.51,,0.001,0.001,122.069,0.0592,0.015,0.0276,2054.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-25",6,4.95,392.56,,0.001,0.001,217.269,0.059,0.019,0.0112,3656.642,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-27",14,11.17,940.55,,0.003,0.001,512.326,0.0591,0.041,0.0153,8621.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-29",4,2.2,141.9,,0,0.001,82.305,0.0593,0.009,0.0328,1386.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-10-31",4,3.45,277.66,,0.001,0.001,152.247,0.059,0.015,0.0138,2561.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-01",5,3.2,253.94,,0.001,0.001,139.914,0.059,0.013,0.0276,2354.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-02",5,3.45,281.18,,0.001,0.001,153.722,0.0592,0.014,0.0144,2588.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-03",4,2.45,169.02,,0,0.001,96.523,0.059,0.01,0.031,1625.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-04",5,3.18,271.68,,0.001,0.001,147.439,0.059,0.013,0.0268,2482.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-05",7,6.2,475.68,,0.001,0.001,264.217,0.059,0.021,0.0101,4446.324,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-06",3,1.45,64.8,,0,0.001,41.907,0.0597,0.006,0.0397,705.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-09",4,2.7,213.58,,0.001,0.001,117.435,0.0593,0.012,0.0138,1976.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-10",8,4.42,266.7,,0.001,0.001,157.541,0.0591,0.016,0.0334,2651.609,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-11",6,3.88,257.35,,0.001,0.001,148.476,0.0592,0.015,0.015,2497.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-12",4,2.2,176.94,,0,0.001,97.321,0.0595,0.011,0.037,1637.473,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-14",4,2.45,191,,0.001,0.001,105.126,0.0595,0.01,0.0173,1768.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-15",6,4.45,349.52,,0.001,0.001,191.734,0.0592,0.015,0.0135,3226.045,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-16",5,3.22,243.9,,0.001,0.001,134.75,0.059,0.012,0.0288,2268.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-18",4,2.21,115.99,,0,0.001,71.978,0.0595,0.008,0.0343,1211.124,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-20",3,1.7,101.18,,0,0.001,60.234,0.0593,0.009,0.021,1013.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-21",3,1.95,89.47,,0,0.001,58,0.059,0.007,0.0203,976.611,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-22",4,2.2,145,,0,0.001,83.485,0.0593,0.01,0.035,1404.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-23",3,1.7,76.55,,0,0.001,49.645,0.0593,0.007,0.015,834.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-24",7,4.19,235.25,,0.001,0.001,142.775,0.059,0.017,0.027,2402.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-25",9,5.9,279.46,,0.001,0.001,180.944,0.0592,0.017,0.0298,3044.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-29",4,2.7,187.7,,0.001,0.001,107.23,0.059,0.012,0.0128,1805.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-11-30",4,2.7,207.8,,0.001,0.001,115.645,0.059,0.012,0.0358,1946.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-01",11,9.87,533.12,,0.002,0.001,334.177,0.0591,0.027,0.0122,5622.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-02",1,0.07,0,,0,0.001,0.539,0.06,0,0.005,9.037,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-04",6,4.4,261.4,,0.001,0.001,156.055,0.0592,0.019,0.0142,2627.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-06",7,5.97,296.5,,0.001,0.001,186.775,0.0591,0.017,0.0101,3143.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-08",4,2.2,158.7,,0,0.001,88.67,0.059,0.01,0.0408,1493.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-09",3,1.47,99.65,,0,0.001,56.593,0.059,0.008,0.0437,951.559,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-10",2,1.45,73.55,,0,0.001,45.645,0.059,0.007,0.0185,768.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-12",6,5.47,347.57,,0.001,0.001,202.888,0.059,0.02,0.0112,3415.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-13",4,2.2,100.3,,0,0.001,65.3,0.059,0.008,0.0328,1099.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-14",1,0.28,0,,0,0.001,2.1,0.059,0.002,0.105,35.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-15",4,2.7,201.16,,0.001,0.001,112.69,0.059,0.011,0.0305,1895.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-16",5,4.2,295.4,,0.001,0.001,168.76,0.059,0.014,0.0152,2838.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"5",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-21",5,3.2,288,,0.001,0.001,151.81,0.059,0.02,0.0292,2554.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-27",2,1.02,83.88,,0,0.001,46.068,0.059,0.011,0.0625,774.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-29",6,3.44,196.81,,0.001,0.001,117.735,0.059,0.017,0.032,1981.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-01",2,1.47,66.7,,0,0.001,42.827,0.0595,0.007,0.0215,719.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-03",3,1.3,50.31,,0,0.001,33.594,0.059,0.009,0.0607,565.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-04",9,5.39,448.58,,0.001,0.001,243.021,0.0592,0.033,0.0328,4088.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-05",10,6.91,573,,0.002,0.001,313.212,0.059,0.034,0.0296,5269.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-06",3,1.72,136.17,,0,0.001,75.399,0.059,0.009,0.022,1268.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-07",2,1.45,113.39,,0,0.001,62.379,0.059,0.013,0.021,1049.017,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-08",7,4.69,221.25,,0.001,0.001,140.01,0.0594,0.019,0.0277,2355.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-09",3,1.72,92.2,,0,0.001,56.126,0.059,0.009,0.0173,944.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-10",2,0.99,57.88,,0,0.001,34.14,0.059,0.011,0.04,575.099,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-11",9,6.67,508.09,,0.001,0.001,282.52,0.059,0.027,0.0181,4754.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-12",8,6.19,536.92,,0.001,0.001,289.761,0.059,0.028,0.0154,4875.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-13",9,7.44,510.13,,0.001,0.001,291.506,0.059,0.026,0.015,4905.647,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-14",9,7.69,596.79,,0.002,0.001,330.527,0.059,0.032,0.0123,5562.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-15",2,1.47,98.53,,0,0.001,56.349,0.059,0.01,0.021,948.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-16",3,2.2,113.02,,0,0.001,70.594,0.059,0.009,0.023,1188.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-17",5,3.97,334.17,,0.001,0.001,181.492,0.059,0.016,0.0158,3054.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-18",6,4.67,349.34,,0.001,0.001,194.435,0.059,0.023,0.0153,3272.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-19",8,6.92,526.13,,0.001,0.001,292.383,0.059,0.029,0.0156,4920.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-20",8,5.94,413.65,,0.001,0.001,235.378,0.0591,0.021,0.0151,3961.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-21",10,8.19,598.81,,0.002,0.001,336.699,0.0592,0.032,0.0123,5663.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-22",2,1.45,90.26,,0,0.001,52.343,0.0595,0.01,0.0215,879.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-23",12,10.17,744.04,,0.002,0.001,416.945,0.0592,0.032,0.0105,7015.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-24",10,7.69,610.56,,0.002,0.001,336.933,0.0591,0.032,0.0138,5670.817,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-25",10,6.63,444.13,,0.001,0.001,254.4,0.0591,0.029,0.0208,4282.497,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-26",10,7.17,571.34,,0.002,0.001,313.623,0.059,0.031,0.0219,5275.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-27",11,8.16,575.62,,0.002,0.001,323.896,0.059,0.032,0.0188,5451.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-28",11,7.9,578.36,,0.002,0.001,323.273,0.0591,0.032,0.0119,5439.179,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-02-29",13,10.15,751.93,,0.002,0.001,418.411,0.0592,0.035,0.017,7041.731,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-01",8,7.45,585.7,,0.002,0.001,320.414,0.059,0.023,0.0096,5393.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-02",10,7.13,520.09,,0.001,0.001,288.675,0.0592,0.025,0.0218,4857.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-03",10,7.44,582.78,,0.002,0.001,320.167,0.0591,0.03,0.0196,5388.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-04",9,7.15,506.81,,0.001,0.001,285.358,0.0592,0.026,0.0109,4799.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-05",11,8.65,623.34,,0.002,0.001,349.557,0.059,0.029,0.0181,5881.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-06",10,8.65,593.87,,0.002,0.001,339.113,0.059,0.029,0.0112,5706.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-07",11,8.4,560.3,,0.002,0.001,324.517,0.059,0.03,0.018,5461.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-15",13,11.01,829.91,,0.002,0.001,452.588,0.059,0.027,0.0075,7616.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-16",15,12.12,976.15,,0.003,0.001,522.454,0.0591,0.039,0.0092,8793.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-17",14,11.91,928.6,,0.003,0.001,499.701,0.0591,0.031,0.0078,8407.473,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-18",16,11.39,901.78,,0.002,0.001,483.848,0.0591,0.033,0.0175,8141.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-19",12,8.42,676.64,,0.002,0.001,361.978,0.059,0.024,0.0216,6090.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-20",10,6.9,512.18,,0.001,0.001,279.39,0.0592,0.019,0.0248,4700.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-21",7,5.7,348.18,,0.001,0.001,200.792,0.0591,0.011,0.0186,3378.284,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-22",6,4.95,376.63,,0.001,0.001,203.832,0.0592,0.014,0.009,3429.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-23",7,4.65,323.87,,0.001,0.001,178.551,0.0591,0.016,0.0209,3005.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-24",17,15.16,1378.41,,0.004,0.001,726.95,0.059,0.047,0.0079,12233.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-25",6,4.95,379.37,,0.001,0.001,204.841,0.0592,0.012,0.0075,3445.417,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-26",6,4.2,328.96,,0.001,0.001,176.108,0.0592,0.011,0.0192,2963.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-27",13,9.9,809.68,,0.002,0.001,432.762,0.059,0.024,0.0195,7280.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-28",12,9.16,735.84,,0.002,0.001,392.936,0.0593,0.025,0.0148,6609.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-29",8,5.16,378.06,,0.001,0.001,205.22,0.059,0.013,0.0174,3453.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-30",11,7.4,621.12,,0.002,0.001,326.716,0.0593,0.022,0.0224,5497.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-03-31",8,5.65,361.68,,0.001,0.001,203.656,0.0591,0.015,0.0198,3428.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-01",10,5.61,415.55,,0.001,0.001,226.002,0.059,0.02,0.0181,3805.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-02",8,5.65,427.6,,0.001,0.001,231.606,0.059,0.017,0.0181,3896.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-03",12,9.34,804.76,,0.002,0.001,424.02,0.059,0.027,0.0198,7134.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-04",16,14.45,1233.35,,0.003,0.001,652.644,0.0591,0.033,0.0106,10982.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-05",17,13.24,1088,,0.003,0.001,575.824,0.0591,0.033,0.0105,9688.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-06",13,8.36,678.16,,0.002,0.001,359.628,0.059,0.024,0.0188,6052.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-07",15,10.08,769.08,,0.002,0.001,413.741,0.0591,0.028,0.0133,6959.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-08",9,6.65,464.58,,0.001,0.001,257.188,0.0591,0.018,0.0168,4325.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-09",12,8.28,740.44,,0.002,0.001,386.456,0.0591,0.026,0.0208,6504.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-10",15,12.28,1118.48,,0.003,0.001,583.876,0.0591,0.028,0.0111,9826.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-11",5,4.08,324.36,,0.001,0.001,172.921,0.059,0.011,0.0092,2911.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-12",10,9.07,713.55,,0.002,0.001,382.996,0.059,0.021,0.0077,6445.411,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-13",17,11.91,970.87,,0.003,0.001,515.238,0.059,0.033,0.0076,8671.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-14",13,10.41,894.65,,0.002,0.001,472.792,0.0592,0.029,0.0141,7955.699,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-15",11,8.16,704.6,,0.002,0.001,374.84,0.0592,0.027,0.0159,6306.932,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-16",20,18.2,1183.52,,0.003,0.001,672.756,0.0593,0.036,0.0104,11316.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-17",11,7.41,585.6,,0.002,0.001,314.825,0.0591,0.021,0.0217,5298.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-18",7,4.83,412.2,,0.001,0.001,218.305,0.0591,0.017,0.0189,3672.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-19",14,11.54,948.58,,0.003,0.001,504.321,0.0591,0.028,0.0122,8485.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-20",6,4.2,373.68,,0.001,0.001,196.584,0.0592,0.014,0.0205,3306.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-21",4,3.7,262.36,,0.001,0.001,145.168,0.059,0.011,0.0098,2443.875,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-22",13,9.11,657.83,,0.002,0.001,364.717,0.059,0.026,0.0147,6136.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-23",6,4.45,373.86,,0.001,0.001,200.783,0.0592,0.015,0.0108,3379.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-24",8,6.33,520.2,,0.001,0.001,278.799,0.0593,0.02,0.0163,4690.329,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-25",5,3.28,269.6,,0.001,0.001,144.552,0.0592,0.011,0.0092,2431.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-26",5,3.96,297,,0.001,0.001,162.2,0.0592,0.011,0.0084,2728.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-27",5,4.2,345.8,,0.001,0.001,186.382,0.059,0.011,0.0078,3135.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-28",5,4.2,359.04,,0.001,0.001,191.404,0.0592,0.013,0.0088,3220.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-29",6,3.85,275.69,,0.001,0.001,153.003,0.0592,0.018,0.0125,2573.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-04-30",5,3.2,156.56,,0,0.001,97.648,0.0594,0.009,0.0268,1641.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-01",6,4.65,277.6,,0.001,0.001,159.955,0.0593,0.017,0.0137,2689.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-02",6,4.95,269.63,,0.001,0.001,160.937,0.059,0.015,0.0107,2706.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-03",5,4.2,309.41,,0.001,0.001,169.159,0.059,0.015,0.0114,2845.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-04",6,4.22,336.56,,0.001,0.001,180.772,0.059,0.015,0.0233,3042.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-05",6,4.95,387.37,,0.001,0.001,209.42,0.059,0.017,0.0103,3524.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-06",6,4.95,368.24,,0.001,0.001,200.733,0.059,0.017,0.0107,3378.341,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-07",4,2.98,184.6,,0.001,0.001,105.336,0.0593,0.012,0.0128,1773.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-08",4,2.73,204.46,,0.001,0.001,110.381,0.059,0.01,0.0283,1857.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-09",6,5.2,393.58,,0.001,0.001,213.118,0.059,0.018,0.0107,3585.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-10",8,4.9,301.73,,0.001,0.001,172.53,0.0591,0.016,0.0299,2902.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-11",5,3.2,277.08,,0.001,0.001,144.268,0.059,0.014,0.027,2428.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-12",5,3.45,293.99,,0.001,0.001,155.156,0.059,0.014,0.0266,2608.873,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-13",6,5.12,295.8,,0.001,0.001,172.888,0.0592,0.016,0.023,2909.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-14",7,4.53,304.63,,0.001,0.001,169.555,0.059,0.014,0.0203,2853.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-16",4,2.95,247.43,,0.001,0.001,130.667,0.059,0.012,0.031,2197.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-17",4,2.2,175.84,,0,0.001,93.592,0.059,0.01,0.0315,1574.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-19",5,3.45,182.24,,0.001,0.001,109.702,0.0592,0.01,0.0152,1846.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-21",8,7.62,400.34,,0.001,0.001,243.17,0.0591,0.019,0.0101,4090.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-22",16,14.7,754.43,,0.002,0.001,459.055,0.0591,0.031,0.0096,7724.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-23",11,8.78,519.3,,0.002,0.001,301.748,0.059,0.023,0.0155,5078.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-25",5,3.2,288.44,,0.001,0.001,151.776,0.0592,0.015,0.0266,2554.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-26",4,3.2,251.34,,0.001,0.001,136.266,0.059,0.014,0.013,2292.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-27",4,2.45,205.27,,0.001,0.001,109.584,0.059,0.012,0.0313,1844.227,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-30",14,12.2,703.96,,0.002,0.001,415.796,0.0591,0.029,0.0138,6999.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-05-31",4,2.7,228.76,,0.001,0.001,122.134,0.059,0.012,0.0308,2055.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-07",3,2.1,151.2,,0,0.001,83.08,0.059,0.011,0.0393,1397.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-08",6,4.5,247.72,,0.001,0.001,146.226,0.0593,0.012,0.0237,2459.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-13",4,2.2,162.08,,0,0.001,88.736,0.059,0.01,0.0305,1494.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-14",4,2.7,230.08,,0.001,0.001,121.773,0.059,0.013,0.0173,2049.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-15",3,1.45,113.25,,0,0.001,61.127,0.0593,0.009,0.0387,1029.347,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-16",4,2.45,207.23,,0.001,0.001,110.053,0.0593,0.012,0.03,1851.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-17",3,1.92,97.26,,0,0.001,59.186,0.059,0.007,0.0147,997.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-18",3,1.45,114.71,,0,0.001,61.86,0.059,0.009,0.039,1040.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-19",4,2.45,189.04,,0.001,0.001,102.289,0.0593,0.011,0.0318,1721.742,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-20",4,2.2,166.56,,0,0.001,91.172,0.0593,0.01,0.034,1533.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-21",4,2.45,205.43,,0.001,0.001,110.123,0.0593,0.012,0.0315,1852.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-22",4,2.7,224.52,,0.001,0.001,120.572,0.059,0.013,0.0325,2029.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-23",3,1.95,168.73,,0,0.001,89.484,0.059,0.011,0.0203,1505.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-24",11,7.65,616.34,,0.002,0.001,333.356,0.059,0.031,0.0244,5608.769,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-25",4,2.45,143.99,,0,0.001,83.737,0.059,0.009,0.0313,1408.609,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-26",5,3.45,249.42,,0.001,0.001,137.488,0.059,0.012,0.025,2312.965,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-27",4,2.7,241.86,,0.001,0.001,126.762,0.059,0.014,0.032,2133.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-28",2,1.49,122.67,,0,0.001,65.259,0.059,0.01,0.0195,1098.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-29",3,2.21,191.59,,0.001,0.001,101.171,0.059,0.014,0.0143,1702.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-01",4,2.45,201.98,,0.001,0.001,107.389,0.0593,0.011,0.0323,1808.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-02",4,3.2,282.5,,0.001,0.001,148.348,0.059,0.015,0.0135,2495.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-03",4,2.71,236.51,,0.001,0.001,125.064,0.059,0.013,0.0333,2103.304,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-04",4,2.71,201.99,,0.001,0.001,110.414,0.059,0.011,0.032,1858.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-05",5,3.2,227.33,,0.001,0.001,125.219,0.059,0.01,0.0256,2106.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-06",6,4.2,364.24,,0.001,0.001,192.724,0.059,0.015,0.0247,3242.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-07",5,3.7,320.76,,0.001,0.001,169.36,0.059,0.015,0.0284,2849.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-08",2,1.45,117.45,,0,0.001,62.959,0.059,0.011,0.018,1059.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-09",5,3.45,265.11,,0.001,0.001,144.705,0.059,0.012,0.0268,2434.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-10",8,6.7,605.48,,0.002,0.001,318.038,0.059,0.025,0.0206,5352.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-11",6,4.95,438.01,,0.001,0.001,232.313,0.059,0.021,0.0245,3908.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-12",6,3.41,235.19,,0.001,0.001,130.688,0.059,0.015,0.0262,2200.107,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-13",3,1.45,74.18,,0,0.001,44.913,0.059,0.007,0.04,755.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-14",5,3.2,260.24,,0.001,0.001,139.512,0.059,0.013,0.027,2346.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-15",4,2.2,190.2,,0.001,0.001,100.472,0.059,0.011,0.0315,1690.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-16",5,3.2,277.44,,0.001,0.001,146.668,0.059,0.014,0.0254,2468.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-17",5,3.45,261.74,,0.001,0.001,142.225,0.059,0.013,0.026,2394.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-18",5,3.2,205.72,,0.001,0.001,117.104,0.059,0.011,0.0262,1971.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-19",5,3.24,229.84,,0.001,0.001,126.676,0.059,0.011,0.0274,2133.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-20",5,3.2,170.08,,0.001,0.001,102.584,0.059,0.01,0.0262,1724.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-21",5,3.2,267.72,,0.001,0.001,142.88,0.059,0.013,0.0256,2404.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-22",4,3.45,291.51,,0.001,0.001,155.116,0.059,0.015,0.0133,2611.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-23",3,1.45,107.39,,0,0.001,58.376,0.059,0.008,0.0403,982.601,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-24",4,2.2,191.16,,0.001,0.001,101.092,0.059,0.012,0.0313,1700.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-25",5,3.45,304.24,,0.001,0.001,160.557,0.059,0.014,0.0272,2701.627,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-26",5,3.7,330.78,,0.001,0.001,174.074,0.059,0.016,0.027,2929.124,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-27",6,4.7,409.46,,0.001,0.001,216.242,0.059,0.019,0.0112,3639.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-28",4,3.21,279.31,,0.001,0.001,148.255,0.059,0.015,0.013,2495.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-30",2,0.55,22.85,,0,0.001,14.7,0.059,0.003,0.0545,247.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-07-31",7,5.7,474.83,,0.001,0.001,255.206,0.059,0.016,0.0079,4295.137,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-03",5,3.45,166.09,,0.001,0.001,103.279,0.0594,0.01,0.0148,1737.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-13",5,3.7,259.44,,0.001,0.001,144.34,0.0592,0.013,0.0274,2427.652,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-14",9,7.7,648.36,,0.002,0.001,346.406,0.0591,0.026,0.0178,5829.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-15",3,1.96,132.92,,0,0.001,74.071,0.059,0.009,0.0393,1245.562,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-17",8,6.96,541.47,,0.001,0.001,294.103,0.0591,0.022,0.0189,4948.871,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-18",10,9.21,797.11,,0.002,0.001,428.07,0.059,0.032,0.0088,7201.973,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-19",7,6.46,469.44,,0.001,0.001,261.006,0.0591,0.021,0.0104,4391.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-20",7,5.7,350.48,,0.001,0.001,201.878,0.059,0.014,0.009,3397.978,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-21",3,1.96,167.64,,0,0.001,89.178,0.059,0.011,0.0397,1501.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-22",5,3.41,230,,0.001,0.001,129.629,0.0594,0.016,0.0128,2180.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-23",4,3.21,263.91,,0.001,0.001,141.795,0.059,0.014,0.0138,2386.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-24",7,5.96,522.71,,0.001,0.001,276.791,0.059,0.024,0.0216,4657.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-25",4,3.21,263.33,,0.001,0.001,141.291,0.0593,0.015,0.0128,2376.641,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-26",2,1.46,76.3,,0,0.001,45.678,0.059,0.008,0.017,768.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-27",9,7.71,643.33,,0.002,0.001,344.186,0.059,0.025,0.0176,5791.303,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-28",4,3.7,293,,0.001,0.001,158.76,0.059,0.016,0.0125,2670.998,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-01",5,4.03,186.6,,0.001,0.001,118.542,0.059,0.011,0.018,1995.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-02",8,3.64,271.92,,0.001,0.001,149.215,0.0591,0.018,0.0404,2510.219,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-03",3,2.2,109.22,,0,0.001,67.27,0.059,0.008,0.0193,1132.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-04",5,3.2,272.5,,0.001,0.001,144.285,0.059,0.013,0.0268,2428.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-05",9,7.85,613.81,,0.002,0.001,331.621,0.059,0.028,0.0114,5579.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-06",6,3.52,176.1,,0.001,0.001,107.12,0.0592,0.01,0.0227,1802.854,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-08",2,1.45,79.8,,0,0.001,47.238,0.059,0.009,0.0195,795.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-09",4,2.2,180.5,,0,0.001,95.998,0.059,0.011,0.0328,1615.583,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-10",4,2.7,191.34,,0.001,0.001,105.554,0.059,0.011,0.0333,1776.609,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-11",8,5.15,328.97,,0.001,0.001,187.887,0.059,0.018,0.0208,3159.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-12",4,2.45,200.04,,0.001,0.001,107.055,0.0593,0.01,0.0165,1801.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-14",4,2.45,193.28,,0.001,0.001,103.827,0.0593,0.01,0.017,1746.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-15",9,6.92,473.24,,0.001,0.001,264.05,0.0591,0.024,0.0107,4440.423,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-16",5,3.22,244.5,,0.001,0.001,131.991,0.059,0.011,0.0284,2221.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-17",4,2.18,149.33,,0,0.001,83.045,0.059,0.01,0.033,1397.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-20",4,2.2,156.25,,0,0.001,86.375,0.059,0.01,0.0333,1453.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-21",5,3.7,180.13,,0.001,0.001,111.611,0.0596,0.011,0.012,1876.311,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-22",8,5.42,328.16,,0.001,0.001,189.228,0.0591,0.019,0.0213,3184.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-24",3,1.47,77.37,,0,0.001,46.464,0.059,0.008,0.04,782.122,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-25",7,5.72,295.31,,0.001,0.001,180.62,0.0593,0.016,0.0224,3038.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-29",3,2.45,172.95,,0,0.001,96.41,0.059,0.013,0.017,1621.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-11-30",4,3.2,236.3,,0.001,0.001,130.1,0.059,0.012,0.0138,2190.295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-01",3,1.47,93.78,,0,0.001,53.767,0.059,0.009,0.0433,904.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-04",7,3.67,248.89,,0.001,0.001,139.58,0.059,0.019,0.038,2349.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-07",7,5.47,271.8,,0.001,0.001,166.871,0.059,0.015,0.013,2808.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-08",4,2.2,167.05,,0,0.001,90.035,0.059,0.011,0.0328,1514.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-09",4,2.45,173.3,,0,0.001,95.22,0.059,0.011,0.0333,1601.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-10",2,1.45,78.05,,0,0.001,46.135,0.059,0.009,0.019,776.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-11",7,4.4,234.7,,0.001,0.001,140.02,0.0591,0.02,0.016,2356.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-12",5,3.97,265.61,,0.001,0.001,149.155,0.059,0.015,0.0272,2508.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-13",4,2.7,207.4,,0.001,0.001,112.555,0.0593,0.012,0.014,1894.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-14",5,3.7,175.35,,0.001,0.001,109.96,0.059,0.012,0.0278,1851.295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-15",4,2.7,193.2,,0.001,0.001,105.97,0.059,0.011,0.0343,1782.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-16",7,4.65,353,,0.001,0.001,192.03,0.0591,0.022,0.0264,3231.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-18",4,2.2,177.3,,0,0.001,95.03,0.0593,0.011,0.0328,1599.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-19",7,4.17,214.2,,0.001,0.001,130.718,0.0591,0.017,0.0241,2199.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-20",4,2.45,194.2,,0.001,0.001,104.43,0.0593,0.011,0.0173,1758.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-21",6,4.45,222.6,,0.001,0.001,137.085,0.0592,0.014,0.0138,2306.615,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-23",4,2.95,137.3,,0,0.001,87.09,0.0595,0.011,0.0133,1465.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"6",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-15",3,1.47,67.61,,0,0.001,43.191,0.059,0.008,0.0287,727.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-17",2,1.43,64.12,,0,0.001,41.579,0.0595,0.008,0.024,699.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-24",5,3.2,287.9,,0.001,0.001,154.28,0.059,0.025,0.0334,2594.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-01-31",1,0.55,33.55,,0,0.001,19.47,0.059,0.01,0.061,327.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-04",3,2.2,181.4,,0,0.001,97.96,0.0593,0.007,0.009,1648.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-05",3,1.45,87.9,,0,0.001,51.84,0.059,0.009,0.0243,872.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-06",2,1.47,117.69,,0,0.001,64.236,0.0595,0.013,0.0205,1079.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-08",3,2.2,104.44,,0,0.001,66.044,0.0593,0.009,0.0173,1110.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-09",3,1.72,86.72,,0,0.001,53.61,0.059,0.009,0.019,902.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-10",2,0.99,57.14,,0,0.001,33.609,0.059,0.015,0.055,565.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-11",6,4.97,405.7,,0.001,0.001,221.453,0.059,0.019,0.017,3727.435,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-12",7,5.44,431,,0.001,0.001,235.807,0.059,0.025,0.0171,3968.559,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-13",9,7.44,486.96,,0.001,0.001,281.248,0.059,0.025,0.0151,4732.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-14",7,5.65,343.44,,0.001,0.001,202.093,0.059,0.026,0.0153,3402.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-16",2,1.47,78.87,,0,0.001,48.006,0.059,0.01,0.0205,807.555,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-17",5,4.2,365.74,,0.001,0.001,196.714,0.059,0.019,0.0176,3310.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-18",5,3.92,263.79,,0.001,0.001,149.607,0.059,0.021,0.0176,2518.147,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-19",7,5.67,422.12,,0.001,0.001,234.354,0.0591,0.026,0.0144,3943.407,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-20",7,4.67,310.63,,0.001,0.001,177.972,0.0591,0.019,0.0194,2993.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-21",10,7.92,584.4,,0.002,0.001,326.128,0.0591,0.03,0.0128,5485.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-22",2,1.45,85.29,,0,0.001,50.314,0.0595,0.009,0.0205,846.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-23",8,6.95,534.5,,0.001,0.001,295.905,0.059,0.023,0.0109,4979.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-24",6,4.2,320.68,,0.001,0.001,177.612,0.059,0.017,0.0265,2988.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-25",11,8.1,569.93,,0.002,0.001,321.282,0.059,0.033,0.0123,5404.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-26",11,9.17,694.81,,0.002,0.001,384.203,0.059,0.033,0.0106,6466.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-27",11,8.12,579.59,,0.002,0.001,325.492,0.0592,0.032,0.0119,5477.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-28",11,8.92,638.61,,0.002,0.001,358.982,0.059,0.031,0.0107,6040.299,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-02-29",9,6.15,435.06,,0.001,0.001,245.265,0.0591,0.023,0.0199,4126.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-01",9,8.12,546.56,,0.002,0.001,310.864,0.0591,0.021,0.0163,5232.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-02",11,8.49,644.96,,0.002,0.001,352.931,0.059,0.03,0.0113,5940.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-03",11,8.9,716.72,,0.002,0.001,389.208,0.059,0.035,0.0116,6550.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-04",11,8.4,611.93,,0.002,0.001,340.83,0.0591,0.03,0.0168,5734.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-05",11,8.9,611.94,,0.002,0.001,345.734,0.0591,0.028,0.0165,5815.732,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-06",11,8.42,635.44,,0.002,0.001,352.754,0.0593,0.031,0.017,5935.393,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-07",6,5.2,386.12,,0.001,0.001,216.672,0.059,0.019,0.0117,3646.237,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-14",5,2.23,160.36,,0,0.001,89.61,0.059,0.015,0.0252,1507.986,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-15",12,9.15,723.58,,0.002,0.001,395.216,0.0592,0.035,0.0168,6650.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-16",16,13.92,1219.56,,0.003,0.001,647.752,0.0591,0.049,0.0093,10899.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-17",14,10.4,781.32,,0.002,0.001,429.492,0.059,0.034,0.0216,7225.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-18",14,10.36,787.2,,0.002,0.001,432.184,0.0591,0.041,0.0163,7272.099,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-19",10,6.65,494.22,,0.001,0.001,272.527,0.0593,0.025,0.0253,4584.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-20",10,6.61,418.45,,0.001,0.001,241.645,0.059,0.027,0.0194,4065.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-21",7,5.2,308.84,,0.001,0.001,182.712,0.0591,0.015,0.0211,3074.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-22",6,4.2,320.84,,0.001,0.001,176.104,0.059,0.015,0.0232,2964.624,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-23",5,3.2,257.48,,0.001,0.001,139.272,0.059,0.014,0.0288,2342.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-24",10,7.11,520.89,,0.001,0.001,289.255,0.059,0.032,0.0126,4868.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-25",17,14.88,1320.35,,0.004,0.001,703.988,0.059,0.059,0.0146,11846.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-26",9,5.88,435.01,,0.001,0.001,239.554,0.0592,0.023,0.0277,4029.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-27",12,8.91,733.52,,0.002,0.001,395.153,0.0593,0.032,0.0213,6648.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-28",12,10.16,795.74,,0.002,0.001,433.542,0.059,0.036,0.011,7297.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-29",4,2.2,152.48,,0,0.001,84.76,0.0593,0.01,0.0288,1425.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-30",14,8.86,717.39,,0.002,0.001,385.826,0.059,0.033,0.0253,6491.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-03-31",8,5.4,401.6,,0.001,0.001,220.218,0.0591,0.023,0.0216,3706.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-01",12,8.36,631.99,,0.002,0.001,347.597,0.0593,0.032,0.0192,5847.869,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-02",9,5.65,437.17,,0.001,0.001,239.663,0.059,0.022,0.0207,4035.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-03",12,7.55,629.33,,0.002,0.001,337.228,0.0592,0.031,0.0278,5673.124,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-04",16,14.2,1288.2,,0.003,0.001,678.648,0.0591,0.045,0.012,11422.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-05",17,13.18,1108.19,,0.003,0.001,590.245,0.0591,0.043,0.0128,9930.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-06",12,6.91,488.44,,0.001,0.001,271.878,0.0592,0.026,0.0273,4574.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-19",5,2.37,112.54,,0,0.001,67.71,0.059,0.008,0.0182,1140.413,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-20",5,3.96,317.76,,0.001,0.001,173.184,0.0594,0.016,0.0118,2913.804,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-21",4,3.45,278.32,,0.001,0.001,151.45,0.059,0.015,0.0135,2547.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-22",13,9.87,701.89,,0.002,0.001,394.506,0.0593,0.034,0.0118,6638.239,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-23",6,4.46,367.88,,0.001,0.001,199.852,0.059,0.018,0.015,3362.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-24",6,5.21,433,,0.001,0.001,236.143,0.059,0.021,0.0117,3974.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-25",5,3.7,299.4,,0.001,0.001,164.352,0.0592,0.015,0.013,2767.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-26",5,3.21,280.2,,0.001,0.001,150.52,0.059,0.016,0.0264,2533.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-27",3,1.96,137.52,,0,0.001,77.13,0.059,0.009,0.02,1297.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-28",6,4.7,415.5,,0.001,0.001,221.73,0.059,0.019,0.0228,3730.836,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-29",10,5.36,297,,0.001,0.001,179.229,0.0592,0.02,0.0262,3016.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-04-30",5,3.95,193.5,,0.001,0.001,122.449,0.059,0.013,0.0124,2059.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-01",4,2.97,247.23,,0.001,0.001,132.599,0.059,0.014,0.0183,2232.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-02",6,5.2,271.89,,0.001,0.001,166.799,0.0595,0.016,0.0113,2805.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-03",5,3.97,346.99,,0.001,0.001,184.402,0.059,0.017,0.0124,3102.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-04",5,3.95,359.42,,0.001,0.001,189.975,0.059,0.017,0.026,3195.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-05",9,5.65,394.12,,0.001,0.001,221.384,0.0591,0.021,0.0289,3726.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-06",6,4.2,297.68,,0.001,0.001,166.404,0.0592,0.016,0.0232,2800.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-07",5,3.95,273.95,,0.001,0.001,154.303,0.0592,0.016,0.0118,2596.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-08",6,4.57,319.14,,0.001,0.001,179.093,0.0592,0.02,0.0247,3012.578,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-09",8,6.28,442.26,,0.001,0.001,246.778,0.059,0.019,0.0193,4151.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-10",9,7.2,465.68,,0.001,0.001,266.468,0.059,0.019,0.0171,4482.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-11",5,3.2,276.84,,0.001,0.001,145.46,0.059,0.014,0.0274,2448.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-12",5,3.47,294.65,,0.001,0.001,156.664,0.059,0.014,0.0244,2636.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-14",6,4.7,298.56,,0.001,0.001,171.998,0.0592,0.017,0.0115,2895.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-16",5,4.2,343.24,,0.001,0.001,185.445,0.0592,0.017,0.016,3119.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-17",4,2.2,184.48,,0,0.001,98.624,0.0593,0.011,0.028,1658.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-24",3,1.7,95.83,,0,0.001,57.537,0.0593,0.007,0.021,967.529,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-25",3,1.95,170.94,,0,0.001,92.186,0.059,0.011,0.021,1551.643,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-26",4,3.45,275.36,,0.001,0.001,150.859,0.059,0.016,0.0138,2538.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-27",5,4.45,270.37,,0.001,0.001,159.585,0.059,0.016,0.0116,2684.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-28",3,1.47,77.7,,0,0.001,47.491,0.059,0.007,0.0363,798.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-30",10,8.95,489.12,,0.002,0.001,298.071,0.0591,0.024,0.0087,5014.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-05-31",4,2.95,235.86,,0.001,0.001,128.403,0.0593,0.013,0.032,2159.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-01",3,1.45,110.55,,0,0.001,59.873,0.059,0.008,0.036,1006.765,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-04",5,3.7,181.36,,0.001,0.001,113.174,0.0592,0.011,0.0246,1905.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-06",6,4.45,267.75,,0.001,0.001,156.562,0.0592,0.015,0.0147,2635.289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-07",3,1.45,123.01,,0,0.001,65.19,0.059,0.01,0.0413,1097.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-08",3,1.45,70.05,,0,0.001,43.409,0.059,0.007,0.0407,731.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-09",4,2.2,104.6,,0,0.001,65.708,0.059,0.008,0.0335,1106.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-13",4,2.45,209.57,,0.001,0.001,112.017,0.0593,0.014,0.0328,1884.957,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-14",3,2.44,216.96,,0.001,0.001,115.86,0.059,0.014,0.0163,1948.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-15",10,7.41,451.25,,0.001,0.001,262.853,0.0591,0.025,0.0177,4424.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-16",3,2.2,194.32,,0.001,0.001,103.6,0.059,0.014,0.017,1742.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-18",2,1.45,109.96,,0,0.001,60.575,0.059,0.01,0.0205,1019.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-19",3,1.95,167.72,,0,0.001,89.856,0.059,0.012,0.0157,1512.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-20",4,2.45,214.78,,0.001,0.001,114.756,0.059,0.013,0.03,1931.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-21",3,1.95,167.77,,0,0.001,90.247,0.059,0.012,0.0157,1519.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-22",3,2.46,208.85,,0.001,0.001,111.735,0.059,0.012,0.0153,1879.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-23",3,2.45,218.75,,0.001,0.001,116.93,0.059,0.012,0.0133,1968.369,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-24",3,2.2,194.79,,0.001,0.001,104.557,0.059,0.013,0.016,1759.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-25",6,4.21,381.46,,0.001,0.001,202.059,0.0592,0.023,0.0238,3399.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-26",7,6.21,538.04,,0.001,0.001,286.694,0.059,0.024,0.0094,4823.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-27",9,5.91,488.06,,0.001,0.001,263.159,0.0592,0.024,0.0194,4427.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-28",3,2.21,192.38,,0.001,0.001,102.228,0.059,0.013,0.022,1720.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-29",4,2.96,255.62,,0.001,0.001,136.608,0.0593,0.014,0.0178,2298.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-06-30",4,3.2,275.86,,0.001,0.001,147.47,0.059,0.014,0.018,2483.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-01",4,2.96,249.01,,0.001,0.001,133.352,0.059,0.014,0.0138,2243.971,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-02",4,2.71,239.8,,0.001,0.001,126.551,0.059,0.014,0.0308,2128.583,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-03",7,5.71,492.81,,0.001,0.001,263.598,0.059,0.024,0.0117,4437.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-04",4,3.46,269.72,,0.001,0.001,147.936,0.059,0.016,0.012,2489.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-05",9,8.2,576.96,,0.002,0.001,323.966,0.059,0.022,0.0104,5450.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-06",5,3.45,310.75,,0.001,0.001,164.152,0.059,0.017,0.0256,2763.307,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-07",4,3.2,282.52,,0.001,0.001,150.086,0.059,0.016,0.014,2524.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-08",3,1.45,120.97,,0,0.001,64.724,0.0593,0.01,0.021,1089.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-09",4,3.2,270.84,,0.001,0.001,145.639,0.0593,0.016,0.0125,2448.669,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-10",7,6.45,568.1,,0.002,0.001,301.486,0.059,0.027,0.0109,5071.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-11",9,8.45,697.76,,0.002,0.001,377.705,0.059,0.029,0.0099,6355.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-12",5,4.2,354.6,,0.001,0.001,189.763,0.059,0.019,0.0118,3193.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-13",3,2.45,192.01,,0.001,0.001,104.805,0.059,0.012,0.0147,1764.257,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-15",5,3.2,276.6,,0.001,0.001,147.72,0.0594,0.014,0.0266,2485.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-16",5,3.2,272.32,,0.001,0.001,145.52,0.059,0.012,0.017,2448.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-17",8,5.14,303.17,,0.001,0.001,178.623,0.0591,0.017,0.0283,3005.267,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-18",5,3.7,249.46,,0.001,0.001,141.644,0.0592,0.014,0.0122,2383.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-19",5,3.2,220.96,,0.001,0.001,123.876,0.059,0.01,0.0248,2085.128,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-20",5,3.2,201.56,,0.001,0.001,116.192,0.0596,0.012,0.025,1954.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-21",5,3.45,294.86,,0.001,0.001,158.117,0.059,0.015,0.015,2660.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-22",4,3.7,270.98,,0.001,0.001,150.444,0.059,0.016,0.0123,2531.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-23",4,2.2,136.72,,0,0.001,79.256,0.0593,0.009,0.029,1332.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-24",4,2.7,223.22,,0.001,0.001,120.286,0.059,0.013,0.0138,2023.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-25",5,3.45,292.01,,0.001,0.001,156.846,0.0592,0.015,0.0264,2640.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-26",5,4.2,366.68,,0.001,0.001,195.472,0.059,0.018,0.0122,3290.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-27",8,6.85,543.39,,0.001,0.001,295.136,0.0591,0.024,0.0106,4967.529,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-28",5,3.45,288.65,,0.001,0.001,155.859,0.0592,0.014,0.0248,2621.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-29",6,4.46,366,,0.001,0.001,198.295,0.059,0.017,0.022,3337.071,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-30",5,4.45,381.29,,0.001,0.001,204.197,0.059,0.018,0.0122,3435.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-07-31",7,5.96,429.08,,0.001,0.001,240.98,0.059,0.019,0.0091,4054.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-03",3,1.46,69.28,,0,0.001,43.532,0.0593,0.006,0.021,732.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-04",4,2.2,184.08,,0.001,0.001,99,0.059,0.012,0.0313,1666.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-05",4,2.2,185.96,,0.001,0.001,100.364,0.059,0.012,0.029,1688.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-07",4,2.21,182.29,,0,0.001,98.899,0.0593,0.011,0.0298,1664.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-08",5,3.46,303.4,,0.001,0.001,161.962,0.059,0.015,0.0248,2725.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-09",5,3.7,320.7,,0.001,0.001,170.402,0.0592,0.016,0.0122,2867.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-10",5,3.21,266.38,,0.001,0.001,143.366,0.059,0.012,0.0244,2412.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-11",4,2.45,189.35,,0.001,0.001,103.438,0.059,0.008,0.0275,1740.297,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-12",7,5.69,428.43,,0.001,0.001,235.961,0.059,0.018,0.0196,3970.871,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-13",6,4.95,324.11,,0.001,0.001,185.667,0.0592,0.016,0.0098,3125.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-14",9,7.45,627.89,,0.002,0.001,338.074,0.059,0.026,0.0182,5687.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-15",6,4.95,310.8,,0.001,0.001,180.138,0.0592,0.014,0.0228,3029.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-16",3,1.95,91.22,,0,0.001,57.731,0.0593,0.007,0.0343,970.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-17",10,8.7,599.48,,0.002,0.001,340.04,0.0591,0.023,0.0165,5721.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-18",10,8.94,730.52,,0.002,0.001,398.534,0.059,0.029,0.0092,6706.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-19",9,7.69,630.5,,0.002,0.001,345.062,0.059,0.025,0.0118,5806.446,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-20",9,7.2,476.04,,0.001,0.001,273.796,0.059,0.018,0.0164,4608.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-21",3,1.95,157.69,,0,0.001,85.834,0.059,0.014,0.0153,1444.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-22",4,2.19,129.48,,0,0.001,76.462,0.059,0.009,0.0295,1286.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-23",4,2.95,239.13,,0.001,0.001,130.245,0.059,0.013,0.0175,2191.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-24",7,5.69,485.56,,0.001,0.001,261.406,0.059,0.022,0.0196,4397.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-25",3,2.69,207.94,,0.001,0.001,113.914,0.059,0.013,0.0137,1916.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-26",5,3.7,201.98,,0.001,0.001,122.14,0.059,0.01,0.0236,2054.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-27",9,6.77,514.91,,0.001,0.001,283.39,0.0591,0.025,0.0129,4768.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-28",5,3.96,296.36,,0.001,0.001,164.344,0.059,0.017,0.0124,2764.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-08-31",4,2.2,139.9,,0,0.001,80.839,0.059,0.009,0.0323,1360.965,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-01",5,4.15,195.7,,0.001,0.001,125.49,0.059,0.011,0.016,2111.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-02",4,2.21,182.16,,0.001,0.001,100.099,0.059,0.012,0.0338,1684.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-03",2,0.96,64.88,,0,0.001,37.282,0.059,0.008,0.064,627.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-04",6,4.95,430.16,,0.001,0.001,233.735,0.059,0.022,0.0118,3933.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-05",8,6.7,454.05,,0.001,0.001,260.274,0.059,0.02,0.0214,4378.933,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-06",6,4.7,370.5,,0.001,0.001,204.9,0.0592,0.017,0.0125,3447.922,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-07",5,3.2,181.64,,0.001,0.001,108.622,0.0592,0.011,0.0254,1828.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-08",20,17.19,836.57,,0.003,0.001,525.799,0.0593,0.035,0.0116,8846.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-10",5,3.2,269.03,,0.001,0.001,142.991,0.059,0.014,0.0294,2406.917,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-11",4,2.2,175.16,,0,0.001,94.23,0.0593,0.01,0.0298,1586.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-12",4,2.95,248.12,,0.001,0.001,132.685,0.059,0.013,0.0283,2232.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-13",7,5.95,526.94,,0.001,0.001,280.123,0.059,0.021,0.0101,4713.209,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-14",6,4.2,306.29,,0.001,0.001,170.195,0.059,0.014,0.0208,2864.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-15",4,2.2,144.98,,0,0.001,82.471,0.059,0.009,0.028,1388.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-16",4,2.2,116.98,,0,0.001,71.197,0.0593,0.008,0.0305,1198.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-17",11,6.55,352.39,,0.001,0.001,214.02,0.0591,0.023,0.0333,3601.329,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-18",10,8.02,503.68,,0.001,0.001,290.599,0.0591,0.022,0.0174,4888.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-19",4,2.95,241.25,,0.001,0.001,129.694,0.0593,0.012,0.0313,2181.778,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-20",7,5.2,417.42,,0.001,0.001,225.334,0.0593,0.018,0.0196,3792.067,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-21",6,4.2,363.9,,0.001,0.001,193.552,0.0592,0.016,0.023,3255.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-22",4,2.2,179.59,,0,0.001,96.541,0.059,0.01,0.0285,1625.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-23",4,2.2,156.11,,0,0.001,86.962,0.059,0.01,0.029,1462.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-25",4,2.2,163.42,,0,0.001,89.86,0.0593,0.01,0.0295,1511.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-26",4,2.2,178.29,,0,0.001,95.408,0.0593,0.01,0.0288,1606.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-27",4,2.2,132.11,,0,0.001,76.91,0.0593,0.009,0.029,1294.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-01",5,3.76,179.68,,0.001,0.001,113.676,0.0592,0.011,0.0152,1912.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-03",3,1.7,98.57,,0,0.001,57.926,0.059,0.008,0.042,973.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-04",6,4.2,322.81,,0.001,0.001,176.416,0.059,0.015,0.022,2968.198,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-05",3,1.95,119.48,,0,0.001,69.335,0.059,0.008,0.0377,1167.811,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-06",7,5.2,399.03,,0.001,0.001,219.656,0.0591,0.016,0.0193,3695.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-07",4,2.45,129.52,,0,0.001,79.072,0.059,0.008,0.0285,1331.459,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-08",3,1.23,92.94,,0,0.001,50.903,0.059,0.008,0.0353,855.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-09",9,5.42,395.38,,0.001,0.001,219.645,0.0593,0.019,0.0238,3694.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-10",5,3.2,257.2,,0.001,0.001,139.211,0.0592,0.013,0.0292,2342.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-11",4,2.2,167.29,,0,0.001,92.047,0.059,0.01,0.0325,1548.279,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-12",6,4.2,339.33,,0.001,0.001,184.676,0.0592,0.017,0.0255,3107.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-13",8,7.13,351.5,,0.001,0.001,221.826,0.0594,0.018,0.0205,3731.953,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-14",14,12.02,582,,0.002,0.001,368.794,0.0592,0.025,0.0086,6205.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-15",8,7.88,387,,0.001,0.001,244.232,0.0594,0.02,0.0099,4109.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-16",3,2.57,119.66,,0,0.001,76.663,0.0593,0.005,0.007,1289.807,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-18",4,2.7,224.58,,0.001,0.001,120.501,0.059,0.012,0.0318,2027.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-20",5,3.2,259.81,,0.001,0.001,140.542,0.059,0.013,0.0238,2366.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-21",4,2.2,153.16,,0,0.001,85.756,0.059,0.009,0.0275,1442.742,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-22",5,3.21,264.94,,0.001,0.001,142.942,0.059,0.013,0.0248,2405.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-23",4,2.2,113.42,,0,0.001,69.999,0.059,0.008,0.0295,1177.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-24",3,1.96,135.28,,0,0.001,76.038,0.059,0.005,0.0117,1279.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-25",4,2.95,219.96,,0.001,0.001,121.076,0.059,0.013,0.0303,2037.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-26",4,2.2,172.81,,0,0.001,94.449,0.059,0.012,0.036,1589.949,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-27",4,2.45,195.97,,0.001,0.001,106.91,0.059,0.012,0.0313,1799.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-29",4,2.2,144.29,,0,0.001,82.88,0.059,0.008,0.0305,1394.594,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-30",4,2.18,181.68,,0,0.001,97.594,0.059,0.011,0.031,1642.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-10-31",6,3.85,271.39,,0.001,0.001,151.996,0.059,0.016,0.0343,2557.441,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-01",14,12.02,750.44,,0.002,0.001,438.687,0.059,0.031,0.0098,7384.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-02",5,3.45,284.22,,0.001,0.001,152.655,0.0592,0.013,0.0154,2569.042,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-03",4,2.7,184.78,,0.001,0.001,104.32,0.0595,0.01,0.028,1755.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-04",5,3.22,274.3,,0.001,0.001,146.27,0.0592,0.014,0.0268,2461.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-05",8,7.2,560.37,,0.002,0.001,305.14,0.0591,0.023,0.0098,5134.027,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-06",4,2.2,120.5,,0,0.001,72.018,0.0593,0.009,0.0283,1211.957,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-09",4,2.22,110.9,,0,0.001,69.04,0.0593,0.01,0.0325,1161.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-10",4,2.7,186.34,,0.001,0.001,104.891,0.059,0.011,0.0328,1764.376,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-11",5,3.95,259.55,,0.001,0.001,149.005,0.0592,0.013,0.0246,2506.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-12",4,2.22,178,,0,0.001,96.465,0.0595,0.011,0.032,1622.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-15",7,5.4,358.25,,0.001,0.001,203.635,0.059,0.024,0.0146,3426.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-16",10,8.15,630.05,,0.002,0.001,345.495,0.059,0.033,0.0124,5811.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-27",3,1.45,67.2,,0,0.001,42.65,0.059,0.007,0.0213,718.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"7",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-15",3,1.45,67.2,,0,0.001,41.38,0.0593,0.006,0.0207,696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-17",2,1.47,67.55,,0,0.001,41.782,0.0595,0.006,0.0195,702.379,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-24",5,3.22,288.08,,0.001,0.001,149.158,0.0594,0.02,0.0396,2509.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-29",3,1.47,105.28,,0,0.001,56.991,0.059,0.008,0.0547,958.707,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-03",3,1.35,55.1,,0,0.001,35.267,0.0593,0.007,0.0587,593.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-04",9,5.7,444.97,,0.001,0.001,236.797,0.0592,0.023,0.0138,3985.022,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-05",3,2.72,240.56,,0.001,0.001,124.627,0.059,0.013,0.013,2097.947,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-06",2,1.45,118,,0,0.001,62.62,0.059,0.012,0.02,1053.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-07",2,1.47,69.87,,0,0.001,42.834,0.059,0.006,0.0185,720.557,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-08",6,3.67,175.63,,0.001,0.001,107.112,0.059,0.014,0.0312,1802.957,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-09",3,2.22,114.75,,0,0.001,68.294,0.059,0.01,0.0147,1149.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-10",2,0.99,59.49,,0,0.001,33.448,0.059,0.015,0.0525,563.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-11",9,6.94,513.51,,0.001,0.001,277.993,0.059,0.021,0.0127,4677.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-12",8,6.19,542.67,,0.001,0.001,282,0.059,0.031,0.0155,4744.709,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-13",9,7.69,520.5,,0.001,0.001,288.775,0.059,0.021,0.0106,4860.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-14",9,7.69,618,,0.002,0.001,327.817,0.059,0.027,0.0106,5517.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-15",3,2.22,170.42,,0,0.001,91.928,0.059,0.011,0.0147,1546.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-16",4,2.7,145.75,,0,0.001,86.346,0.059,0.012,0.027,1452.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-17",5,4.22,383.52,,0.001,0.001,198.907,0.059,0.019,0.016,3345.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-18",6,4.69,349.04,,0.001,0.001,188.114,0.059,0.028,0.0198,3166.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-19",6,4.15,281.38,,0.001,0.001,154.547,0.0592,0.017,0.0153,2599.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-20",8,6.19,436.64,,0.001,0.001,238.803,0.059,0.019,0.0135,4019.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-21",9,7.42,525.49,,0.001,0.001,287.918,0.0592,0.023,0.01,4843.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-22",3,1.45,85.9,,0,0.001,49.073,0.059,0.007,0.039,825.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-07",1,0.38,3.04,,0,0.001,4.522,0.06,0.006,0.156,75.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-08",10,5.24,444.19,,0.001,0.001,233.249,0.0593,0.026,0.0486,3925.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-09",15,13.85,1155.76,,0.003,0.001,613.381,0.059,0.054,0.0137,10320.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-10",15,13.03,998.77,,0.003,0.001,541.835,0.0591,0.045,0.0139,9119.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-11",14,10.65,910.69,,0.002,0.001,481.548,0.059,0.047,0.0279,8104.387,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-12",10,8.84,686.32,,0.002,0.001,371.408,0.059,0.047,0.0169,6249.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-13",6,5.45,460.74,,0.001,0.001,244.34,0.059,0.024,0.0127,4109.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-14",13,11.65,840.44,,0.002,0.001,464.071,0.0592,0.043,0.0138,7806.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-15",7,6.45,572.74,,0.002,0.001,298.963,0.059,0.03,0.0134,5031.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-16",13,9.11,747.85,,0.002,0.001,395.54,0.0592,0.043,0.0212,6655.551,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-17",9,6.67,388.28,,0.001,0.001,223.771,0.0591,0.027,0.0252,3764.951,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-18",4,2.95,205.55,,0.001,0.001,113.152,0.059,0.016,0.0203,1903.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-19",11,8.88,709.66,,0.002,0.001,378.575,0.059,0.04,0.0218,6371.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-20",9,6.65,420.61,,0.001,0.001,238.547,0.0591,0.029,0.0256,4014.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-21",5,4.45,367.65,,0.001,0.001,195.433,0.059,0.023,0.0138,3287.951,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-22",6,5.2,321.32,,0.001,0.001,184.172,0.059,0.019,0.0132,3098.591,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-23",5,3.95,235.37,,0.001,0.001,135.662,0.0594,0.017,0.0178,2282.662,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-24",5,2.9,170.2,,0,0.001,98.955,0.0592,0.019,0.0368,1664.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-25",9,5.65,366.09,,0.001,0.001,206.328,0.0592,0.024,0.0301,3472.185,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-26",17,16.45,1469.37,,0.004,0.001,762.728,0.059,0.061,0.0101,12835.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-27",9,6.65,381.79,,0.001,0.001,222.891,0.059,0.024,0.0224,3750.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-28",9,6.67,488.47,,0.001,0.001,266.051,0.0592,0.027,0.0223,4476.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-29",5,3.7,283.92,,0.001,0.001,151.508,0.059,0.014,0.0262,2549.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-30",10,7.9,558.4,,0.002,0.001,304.384,0.0591,0.028,0.0132,5121.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-03-31",6,3.65,208.21,,0.001,0.001,120.564,0.059,0.017,0.0207,2029.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-01",6,3.9,286.54,,0.001,0.001,156.034,0.0592,0.02,0.0255,2624.182,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-02",7,5.15,396.37,,0.001,0.001,213.497,0.059,0.024,0.0151,3592.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-03",11,7.3,610.89,,0.002,0.001,321.463,0.059,0.033,0.0225,5410.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-04",16,12.66,1130.59,,0.003,0.001,587.751,0.0591,0.042,0.0186,9887.917,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-05",7,5.28,402.31,,0.001,0.001,216.117,0.0591,0.017,0.0119,3635.009,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-06",10,5.86,387.72,,0.001,0.001,215.084,0.0591,0.025,0.0296,3617.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-07",11,7.11,429.85,,0.001,0.001,245.256,0.0592,0.027,0.0252,4126.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-08",7,5.4,361.16,,0.001,0.001,201.014,0.0591,0.024,0.0137,3381.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-09",9,6.65,470.97,,0.001,0.001,258.158,0.0592,0.026,0.0223,4345.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-10",4,2.7,181.1,,0.001,0.001,101.204,0.059,0.011,0.018,1702.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-11",9,7.45,611.22,,0.002,0.001,321.87,0.059,0.031,0.0128,5416.279,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-12",8,6.45,496.82,,0.001,0.001,265.645,0.0591,0.022,0.0194,4469.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-13",5,3.45,334.16,,0.001,0.001,171.141,0.059,0.017,0.0172,2879.298,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-14",9,7.9,598.83,,0.002,0.001,324.089,0.0591,0.029,0.0113,5452.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-15",3,1.45,106.15,,0,0.001,57.758,0.0593,0.009,0.0427,972.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-16",8,6.41,537.84,,0.001,0.001,285.703,0.0591,0.03,0.0155,4807.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-17",6,5.45,436.73,,0.001,0.001,233.327,0.059,0.02,0.0115,3923.542,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-18",6,3.83,310.55,,0.001,0.001,165.043,0.0592,0.019,0.0277,2777.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-19",13,11.54,954.84,,0.003,0.001,505.184,0.0591,0.036,0.0095,8500.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-20",5,2.92,189.6,,0.001,0.001,106.46,0.0592,0.014,0.028,1791.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-21",5,3.33,267.18,,0.001,0.001,144.48,0.059,0.019,0.0342,2429.817,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-22",6,3.78,297.78,,0.001,0.001,160.268,0.059,0.014,0.0127,2696.922,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-23",4,2.46,214.5,,0.001,0.001,112.636,0.059,0.013,0.0203,1894.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-24",5,4.71,403.7,,0.001,0.001,213.365,0.059,0.02,0.0118,3590.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-25",5,3.71,304.62,,0.001,0.001,162.418,0.0592,0.015,0.0172,2732.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-26",4,2.21,199.46,,0.001,0.001,104.211,0.0593,0.013,0.0365,1754.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-27",2,1.46,86.18,,0,0.001,50.01,0.059,0.01,0.0205,841.258,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-28",5,3.71,335.51,,0.001,0.001,175.713,0.059,0.018,0.0278,2958.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-29",3,1.9,103.46,,0,0.001,61.896,0.0597,0.01,0.028,1040.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-04-30",4,2.95,164.37,,0,0.001,97.849,0.0593,0.012,0.0183,1647.295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-01",5,3.97,213.37,,0.001,0.001,127.813,0.0592,0.014,0.0158,2150.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-02",5,3.95,236.61,,0.001,0.001,136.884,0.0592,0.015,0.0134,2302.221,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-03",7,6.62,423.46,,0.001,0.001,240.356,0.059,0.021,0.0114,4046.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-04",11,10.55,666.35,,0.002,0.001,379.23,0.0591,0.03,0.0099,6380.139,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-05",3,1.45,70.13,,0,0.001,42.936,0.059,0.007,0.0403,723.266,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-06",4,3.2,194.25,,0.001,0.001,111.784,0.0595,0.015,0.0125,1879.783,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-07",3,1.95,146.06,,0,0.001,79.355,0.059,0.012,0.0193,1335.711,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-08",5,3.95,289.34,,0.001,0.001,157.853,0.0592,0.016,0.013,2656.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-09",8,5.82,405.7,,0.001,0.001,223.852,0.059,0.022,0.0304,3766.932,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-10",13,11.45,669.97,,0.002,0.001,389.52,0.0591,0.026,0.0117,6556.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-11",8,4.74,259.7,,0.001,0.001,152.641,0.059,0.017,0.0335,2568.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-12",5,3.97,342.31,,0.001,0.001,178.597,0.0592,0.017,0.0128,3005.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-13",4,2.95,228.65,,0.001,0.001,122.927,0.059,0.016,0.0175,2068.871,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-14",6,5.2,335.88,,0.001,0.001,189.458,0.0592,0.018,0.012,3187.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-15",4,2.2,144.04,,0,0.001,81.052,0.0593,0.011,0.0395,1364.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-16",4,2.95,271.26,,0.001,0.001,140.045,0.059,0.015,0.0338,2355.799,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-18",6,4.95,268.12,,0.001,0.001,160.428,0.059,0.017,0.0147,2698.334,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-23",2,1.7,150.67,,0,0.001,78.644,0.059,0.014,0.0205,1322.221,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-24",2,1.45,73.08,,0,0.001,44.776,0.059,0.009,0.02,753.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-25",3,1.95,173.47,,0,0.001,91.032,0.059,0.012,0.0227,1531.119,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-26",6,4.7,396.7,,0.001,0.001,210.548,0.0592,0.02,0.0235,3542.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-27",6,4.95,348.59,,0.001,0.001,194.248,0.059,0.018,0.015,3267.473,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-28",3,1.47,112.52,,0,0.001,61.072,0.059,0.011,0.0403,1027.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-30",6,4.45,273.61,,0.001,0.001,157.721,0.0592,0.013,0.0185,2654.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-05-31",2,1.45,96.57,,0,0.001,54.056,0.059,0.011,0.022,910.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-03",3,1.45,67.75,,0,0.001,41.884,0.0597,0.008,0.042,704.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-06",2,1.07,66.91,,0,0.001,37.689,0.059,0.009,0.063,633.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-08",3,1.45,69.61,,0,0.001,42.777,0.0597,0.008,0.046,720.229,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-14",3,1.7,104.5,,0,0.001,59.57,0.059,0.009,0.022,1003.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-15",2,0.2,0.96,,0,0.001,1.96,0.0595,0.002,0.1275,33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-16",3,2.21,195.1,,0.001,0.001,101.739,0.059,0.014,0.018,1712.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-20",4,2.71,234.42,,0.001,0.001,123.577,0.059,0.014,0.0188,2077.823,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-22",3,2.21,184.75,,0,0.001,97.65,0.059,0.012,0.0223,1644.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-23",3,1.96,165.44,,0,0.001,87.598,0.0593,0.012,0.0223,1473.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-24",4,2.95,260.48,,0.001,0.001,136.908,0.059,0.015,0.0143,2304.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-25",6,4.21,385.46,,0.001,0.001,200.177,0.0592,0.025,0.0248,3370.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-26",4,3.21,284.5,,0.001,0.001,148.184,0.059,0.015,0.0118,2495.187,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-27",5,3.71,290.77,,0.001,0.001,156.394,0.059,0.015,0.0204,2630.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-28",2,1.61,131.14,,0,0.001,69.273,0.059,0.012,0.021,1165.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-29",4,2.71,237.09,,0.001,0.001,124.327,0.059,0.014,0.019,2093.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-01",4,2.96,244.74,,0.001,0.001,129.612,0.059,0.015,0.0153,2180.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-02",3,2.46,215.5,,0.001,0.001,112.456,0.059,0.016,0.0163,1891.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-03",4,2.71,238.51,,0.001,0.001,124.906,0.059,0.015,0.034,2102.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-04",6,3.66,246.95,,0.001,0.001,137.412,0.0593,0.024,0.022,2312.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-05",8,7.46,578.57,,0.002,0.001,311.912,0.059,0.026,0.0108,5248.741,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-06",5,3.45,304.2,,0.001,0.001,159.145,0.0592,0.017,0.027,2678.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-07",7,4.4,341.13,,0.001,0.001,183.289,0.059,0.022,0.0277,3084.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-08",3,1.7,142.8,,0,0.001,75.162,0.059,0.012,0.0407,1264.824,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-09",4,3.2,267.1,,0.001,0.001,141.303,0.0593,0.018,0.014,2376.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-10",7,6.45,563.97,,0.001,0.001,295.503,0.059,0.029,0.012,4973.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-11",9,8.45,693.01,,0.002,0.001,370.077,0.059,0.029,0.0101,6224.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-12",5,4.45,376.24,,0.001,0.001,198.231,0.059,0.02,0.013,3335.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-13",3,2.45,194.29,,0.001,0.001,104.04,0.059,0.013,0.0167,1750.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-18",5,3.65,241.03,,0.001,0.001,135.609,0.059,0.014,0.0176,2280.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-19",4,2.16,140.36,,0,0.001,78.9,0.059,0.01,0.039,1328.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-20",4,2.15,108.56,,0,0.001,65.989,0.0593,0.009,0.0408,1110.472,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-21",5,2.92,174.2,,0.001,0.001,100.052,0.059,0.014,0.0264,1683.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-22",4,3.46,274.49,,0.001,0.001,147.398,0.059,0.016,0.0143,2480.656,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-24",3,2.7,234.69,,0.001,0.001,123.079,0.059,0.016,0.0163,2070.439,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-25",4,2.45,214.89,,0.001,0.001,112.285,0.0593,0.014,0.0323,1888.825,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-26",5,4.2,376.5,,0.001,0.001,197.232,0.059,0.02,0.0134,3318.454,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-27",7,6.35,480.65,,0.001,0.001,261.195,0.059,0.021,0.0111,4394.535,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-28",3,1.96,163.42,,0,0.001,86.476,0.059,0.012,0.017,1455.409,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-29",5,3.7,295.82,,0.001,0.001,158.954,0.059,0.016,0.0168,2676.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-30",5,4.2,341.82,,0.001,0.001,182.538,0.059,0.017,0.0122,3072.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-07-31",6,5.2,416.18,,0.001,0.001,224.232,0.059,0.019,0.0145,3772.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-03",5,3.83,188.5,,0.001,0.001,116.459,0.0592,0.013,0.021,1958.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-05",4,2.45,213.23,,0.001,0.001,112.48,0.0593,0.014,0.0215,1893.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-07",4,2.2,184.92,,0,0.001,98.048,0.059,0.013,0.0348,1649.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-08",3,1.7,141.17,,0,0.001,75.205,0.059,0.011,0.023,1265.045,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-09",4,3.2,288.73,,0.001,0.001,150.173,0.059,0.018,0.0155,2526.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-10",5,3.42,243.72,,0.001,0.001,133.465,0.0592,0.018,0.0296,2245.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-11",3,1.7,109.83,,0,0.001,62.262,0.059,0.008,0.0193,1047.383,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-12",5,3.95,292.51,,0.001,0.001,160.041,0.059,0.015,0.0286,2693.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-13",5,4.46,301.66,,0.001,0.001,168.262,0.059,0.017,0.0126,2831.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-14",9,7.46,594.84,,0.002,0.001,318.772,0.0591,0.025,0.0176,5364.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-15",3,1.96,154.3,,0,0.001,82.622,0.059,0.012,0.0427,1389.339,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-16",3,1.96,88.89,,0,0.001,56.084,0.059,0.008,0.0383,943.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-17",8,7.71,573.19,,0.002,0.001,314.149,0.059,0.025,0.0098,5284.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-18",10,9.46,815.46,,0.002,0.001,434.556,0.059,0.033,0.0092,7314.194,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-19",9,7.7,647.22,,0.002,0.001,347.108,0.059,0.026,0.0176,5840.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-20",9,7.21,493.46,,0.001,0.001,276.603,0.059,0.021,0.0196,4653.515,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-21",5,3.21,271.46,,0.001,0.001,143.89,0.059,0.016,0.0334,2421.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-22",6,3.67,222.65,,0.001,0.001,128.441,0.0592,0.015,0.0303,2161.458,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-23",4,2.96,244,,0.001,0.001,130.04,0.059,0.014,0.0183,2187.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-24",7,5.96,514.18,,0.001,0.001,271.792,0.059,0.024,0.0209,4575.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-25",3,2.7,211.94,,0.001,0.001,114.442,0.059,0.014,0.0157,1926.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-26",2,1.46,73.06,,0,0.001,44.597,0.059,0.008,0.021,750.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-27",6,4.45,365.15,,0.001,0.001,194.86,0.059,0.018,0.025,3278.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-28",4,3.18,243.57,,0.001,0.001,132.641,0.059,0.013,0.0188,2231.957,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-01",5,3.2,139.15,,0,0.001,89.681,0.0592,0.011,0.0398,1508.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-02",13,11.21,657.43,,0.002,0.001,388.108,0.0591,0.029,0.0192,6532.181,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-04",7,5.45,454.96,,0.001,0.001,244.003,0.059,0.022,0.0214,4106.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-05",10,8.18,531.98,,0.002,0.001,301.939,0.0591,0.033,0.0236,5083.475,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-06",6,5.2,406.46,,0.001,0.001,222.084,0.059,0.018,0.0152,3736.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-08",7,5.7,275.98,,0.001,0.001,170.681,0.0593,0.013,0.0114,2871.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-10",5,3.2,272.16,,0.001,0.001,142.217,0.0594,0.015,0.0304,2392.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-11",4,2.2,177.16,,0,0.001,93.856,0.0595,0.011,0.0353,1578.921,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-12",4,2.7,223.33,,0.001,0.001,120.206,0.059,0.013,0.0313,2023.655,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-13",7,5.95,475.94,,0.001,0.001,259.422,0.059,0.022,0.0111,4366.227,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-14",4,2.45,151.28,,0,0.001,88.628,0.059,0.011,0.031,1490.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-16",4,2.2,109.98,,0,0.001,69.162,0.0593,0.009,0.036,1163.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-17",10,7.17,397.64,,0.001,0.001,240.787,0.0593,0.025,0.025,4051.365,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-19",4,2.96,242.37,,0.001,0.001,130.304,0.059,0.013,0.03,2192.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-20",8,6.21,464.94,,0.001,0.001,256.895,0.0591,0.019,0.0201,4322.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-21",6,4.2,364.46,,0.001,0.001,193.656,0.059,0.017,0.025,3258.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-22",4,2.2,179.24,,0,0.001,96.527,0.0593,0.011,0.0308,1623.798,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-23",4,2.2,139.56,,0,0.001,80.238,0.0595,0.009,0.0375,1349.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-26",6,3.49,258.76,,0.001,0.001,142.265,0.059,0.019,0.0282,2394.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-27",4,2.2,134.56,,0,0.001,78.092,0.059,0.009,0.0403,1314.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-01",5,3.53,167.57,,0.001,0.001,106.1,0.0592,0.011,0.0264,1786.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-03",2,1.47,87.27,,0,0.001,50.523,0.059,0.011,0.023,850.194,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-04",4,2.2,133.03,,0,0.001,77.556,0.0593,0.009,0.0328,1305.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-08",4,2.2,177.24,,0,0.001,95.866,0.0593,0.011,0.032,1613.873,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-10",5,3.2,270.24,,0.001,0.001,145.527,0.0592,0.015,0.0274,2448.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-11",4,2.2,167.85,,0,0.001,92.836,0.059,0.011,0.0325,1562.219,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-13",11,10.88,541.64,,0.002,0.001,340.7,0.0591,0.026,0.0093,5734.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-14",23,22.07,1098,,0.004,0.001,693.218,0.0591,0.041,0.0075,11668.543,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-15",8,7.88,381,,0.001,0.001,243.532,0.059,0.02,0.0103,4099.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-16",3,2.57,117.66,,0,0.001,76.406,0.0593,0.004,0.0073,1286.079,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-21",4,2.2,180.5,,0,0.001,98.07,0.059,0.012,0.0343,1651.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-22",5,3.2,260.33,,0.001,0.001,141.289,0.059,0.014,0.0284,2376.663,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-24",4,2.73,185.08,,0.001,0.001,105.53,0.059,0.012,0.0183,1775.127,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-25",4,3.45,255.34,,0.001,0.001,140.986,0.059,0.015,0.0153,2372.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-26",4,2.2,181.76,,0,0.001,98.446,0.0593,0.012,0.0345,1655.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-27",4,2.2,177.33,,0,0.001,96.735,0.0593,0.011,0.033,1627.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-29",4,2.2,144.98,,0,0.001,83.788,0.059,0.01,0.0368,1409.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-01",4,2.7,209.66,,0.001,0.001,115.198,0.059,0.012,0.0183,1938.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-02",4,2.72,168.5,,0,0.001,98.363,0.059,0.011,0.0173,1655.258,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-03",2,1.45,70.89,,0,0.001,44.399,0.059,0.009,0.0195,747.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-04",5,3.72,274.04,,0.001,0.001,152.248,0.0592,0.014,0.0166,2562.044,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-05",7,6.22,475.13,,0.001,0.001,260.539,0.059,0.022,0.011,4382.771,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-06",2,1.47,85.38,,0,0.001,49.89,0.059,0.01,0.0195,840.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-08",2,1.45,81.65,,0,0.001,48.08,0.059,0.009,0.021,809.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-09",4,2.97,227.8,,0.001,0.001,123.948,0.059,0.015,0.0155,2084.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-10",4,2.22,175.05,,0,0.001,94.723,0.059,0.012,0.036,1593.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-11",4,2.47,189,,0.001,0.001,103.718,0.0593,0.009,0.0148,1745.997,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-12",4,2.22,176.9,,0,0.001,96.018,0.059,0.012,0.0328,1616.276,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-14",4,2.47,200.6,,0.001,0.001,107.918,0.059,0.012,0.0223,1815.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-15",5,3.22,235.65,,0.001,0.001,130.678,0.059,0.013,0.0284,2198.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-16",5,3.22,240.25,,0.001,0.001,132.173,0.0594,0.013,0.0322,2223.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-19",2,1.45,75.45,,0,0.001,46.235,0.0595,0.01,0.02,777.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-20",3,1.45,73.35,,0,0.001,45.5,0.059,0.009,0.0443,766.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-21",4,2.7,126.6,,0,0.001,80.86,0.0593,0.01,0.0198,1360.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-23",3,1.97,89.13,,0,0.001,57.664,0.059,0.009,0.0183,970.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-24",6,3.92,238.3,,0.001,0.001,140.47,0.059,0.019,0.021,2363.647,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-25",3,1.72,78.86,,0,0.001,50.645,0.059,0.009,0.044,852.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-28",2,1.45,64.1,,0,0.001,41.785,0.0595,0.009,0.022,702.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-29",4,3.2,223.6,,0.001,0.001,126.995,0.059,0.015,0.015,2136.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-11-30",4,2.95,138.75,,0,0.001,88.975,0.059,0.011,0.0155,1496.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-01",7,4.42,268.52,,0.001,0.001,159.742,0.059,0.02,0.0371,2688.113,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-02",12,9.42,502.75,,0.002,0.001,312.915,0.0591,0.028,0.0181,5266.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-04",3,2.2,140.8,,0,0.001,81.19,0.0593,0.013,0.0167,1365.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-06",3,1.45,101.25,,0,0.001,56.425,0.059,0.008,0.0407,949.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-08",3,1.45,94.55,,0,0.001,53.43,0.059,0.008,0.0407,899.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-09",3,1.47,103.1,,0,0.001,57.229,0.059,0.01,0.0407,963.046,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-10",5,4.2,252.3,,0.001,0.001,146.64,0.059,0.014,0.0116,2468.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-11",2,1.45,67,,0,0.001,42.585,0.059,0.008,0.019,716.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-12",4,2.97,205.75,,0.001,0.001,115.583,0.059,0.014,0.0148,1944.851,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-13",4,2.22,177.5,,0,0.001,96.37,0.0593,0.012,0.0343,1620.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-14",3,1.45,66.65,,0,0.001,42.84,0.059,0.008,0.0417,721.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Sentinel Energy Center, LLC",57482,"8",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-02",3,2.21,54.01,,0,0.0007,33.603,0.0593,0.007,0.026,564.557,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-13",2,1.25,30,,0,0.001,19.015,0.059,0.005,0.0385,319.959,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-15",3,1.5,35.31,,0,0.001,22.365,0.0593,0.004,0.0297,377.473,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-16",2,1.18,29.96,,0,0.0005,18.418,0.059,0.006,0.034,310.442,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-17",2,1.28,39.3,,0,0.001,23.476,0.0595,0.007,0.042,395.058,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-29",6,3.65,88.85,,0,0.0008,55.955,0.0593,0.01,0.0288,941.108,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-30",3,1.68,39.17,,0,0.001,25.057,0.0597,0.006,0.0337,421.272,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-02",2,1.17,26.55,,0,0.0005,17.142,0.059,0.005,0.033,288.291,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-04",3,2.05,53.6,,0,0.0007,32.79,0.059,0.006,0.0253,552.992,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-07",11,10.62,511.92,,0.002,0.0009,282.814,0.0591,0.027,0.0127,4758.896,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-10",7,4.74,124.68,,0,0.0007,76.374,0.0596,0.013,0.0271,1284.338,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-13",5,3.17,77.7,,0,0.0006,48.829,0.0596,0.01,0.0276,820.463,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-14",5,3.15,88.26,,0,0.0008,53.001,0.059,0.012,0.0262,892.089,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-21",2,1.17,25.68,,0,0.001,16.647,0.0595,0.007,0.0435,280.071,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-24",7,4.65,125.19,,0,0.0007,75.805,0.0594,0.012,0.0281,1275.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-25",9,6.63,174.66,,0.001,0.0008,108.339,0.0591,0.013,0.0191,1823.461,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-26",2,1.2,27.09,,0,0.0005,17.202,0.059,0.008,0.0525,290.022,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-27",3,1.69,39.95,,0,0.0007,24.874,0.0593,0.007,0.038,418.618,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-01",2,0.85,19.75,,0,0.0005,12.605,0.0595,0.008,0.0735,212.28,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-06",4,2.12,64.12,,0,0.0008,38.61,0.0595,0.006,0.018,649.698,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-10",3,1.69,44.57,,0,0.0007,27.67,0.0597,0.008,0.04,465.712,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-11",3,2.17,93.03,,0,0.0007,52.122,0.059,0.011,0.03,877.597,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-12",4,1.63,68.59,,0,0.001,38.696,0.0593,0.01,0.031,651.353,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-13",9,7.45,300.71,,0.001,0.001,170.534,0.0593,0.022,0.0221,2868.887,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-14",9,6.71,286.64,,0.001,0.0009,160.535,0.0591,0.018,0.0174,2702.096,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-15",3,1.96,83.36,,0,0,46.716,0.059,0.007,0.0187,785.86,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-16",4,2.31,61.88,,0,0.0008,37.517,0.0593,0.011,0.0335,631.599,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-17",2,1.18,27.88,,0,0.0005,17.288,0.0595,0.005,0.032,290.256,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-30",3,1.22,27.67,,0,0.0007,17.79,0.0593,0.009,0.0523,299.213,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-02",2,1.45,55.95,,0,0.001,31.565,0.059,0.012,0.0505,531.48,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-06",4,2.22,53.38,,0,0.0008,33.756,0.0593,0.005,0.0233,568.876,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-07",6,3.81,93.54,,0,0.0008,57.902,0.0593,0.013,0.03,973.496,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-08",3,1.7,40.1,,0,0.0007,25.65,0.0597,0.004,0.0227,430.89,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-14",4,2.95,73,,0,0.0008,45.755,0.0595,0.006,0.0253,769.455,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-16",2,1.72,55.08,,0,0.001,32.354,0.0595,0.006,0.0225,544.091,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-17",2,1.68,41.19,,0,0.001,25.967,0.0595,0.009,0.04,436.998,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-23",4,2.72,70.02,,0,0.001,43.825,0.0593,0.006,0.027,738.895,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-24",4,2.69,75.45,,0,0.0008,46.345,0.0595,0.007,0.0278,778.832,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-28",4,2.43,60.18,,0,0.001,38.502,0.0595,0.005,0.0278,648.078,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-29",7,3.34,79.48,,0,0.0007,51.198,0.0594,0.006,0.0199,861.552,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-05",4,2.7,69.5,,0,0.0008,43.33,0.0595,0.005,0.0235,729.02,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-06",4,2.35,58.1,,0,0.001,36.265,0.0595,0.003,0.0215,609.69,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-07",5,3.45,89.35,,0,0.0006,55.96,0.0596,0.006,0.0188,940.51,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-08",7,4.99,126.91,,0,0.0006,79.115,0.0593,0.012,0.0231,1331.244,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-11",2,1.41,51.34,,0,0.001,30.008,0.059,0.012,0.0525,505.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-15",2,1.43,37.45,,0,0.001,22.845,0.0595,0.008,0.036,384.751,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-16",5,3.68,104.88,,0,0.001,63.704,0.0598,0.01,0.0262,1070.752,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-19",11,10.12,271.16,,0.001,0.0009,167.512,0.059,0.011,0.0102,2821.324,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-20",12,11.1,287.1,,0.001,0.001,180.13,0.0591,0.01,0.0085,3033.2,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-26",9,7.88,288.08,,0.001,0.0009,170.004,0.0592,0.013,0.0141,2861.388,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-27",3,1.14,42.33,,0,0.0003,24.811,0.0597,0.004,0.0213,416.763,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-28",6,2.37,57.13,,0,0.0005,36.489,0.0593,0.004,0.023,613.037,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-29",2,1.2,27.68,,0,0.0005,17.858,0.0595,0.005,0.0335,300.322,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-02",6,2.85,66.35,,0,0.0008,42.532,0.0593,0.007,0.024,715.943,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-03",9,7.45,210.85,,0.001,0.001,128.89,0.0598,0.009,0.0137,2165.515,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-04",6,5.2,136.2,,0,0.0008,84.16,0.0593,0.011,0.0203,1415.96,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-05",4,2.23,53.49,,0,0.0008,33.579,0.0598,0.005,0.0213,564.928,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-08",6,4.43,116.87,,0,0.0008,72.579,0.0595,0.008,0.0187,1221.812,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-09",5,4.4,123.74,,0,0.001,76.116,0.0592,0.008,0.015,1281.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-10",9,6.58,217.42,,0.001,0.0008,128.65,0.0592,0.011,0.016,2165.13,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-11",5,3.7,113.5,,0,0.0008,67.69,0.0596,0.007,0.015,1139.61,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-17",4,2.16,53.44,,0,0.0008,33.408,0.0595,0.004,0.0195,562.984,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-18",5,3.22,79.94,,0,0.0008,50.828,0.059,0.006,0.0192,855.412,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-19",3,1.26,30.5,,0,0.0007,19.238,0.0597,0.004,0.0237,324.39,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-21",19,18.63,525.38,,0.002,0.001,323.18,0.0592,0.022,0.0095,5437.733,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-22",7,4.28,111.08,,0,0.0009,69.958,0.0597,0.007,0.018,1175.12,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-23",4,2.86,73.5,,0,0.001,46.656,0.059,0.006,0.0203,784.639,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-24",5,3.41,88.54,,0,0.0006,55.861,0.0596,0.008,0.0204,940.681,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-25",10,7.23,199.34,,0.001,0.0008,122.6,0.0595,0.011,0.0148,2063.019,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-26",7,5.7,166.3,,0.001,0.001,100.902,0.0593,0.008,0.0133,1698.242,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-27",3,2.68,110.69,,0,0.001,62.904,0.0597,0.008,0.0163,1057.289,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-29",3,1.96,48.96,,0,0.001,30.512,0.0593,0.006,0.0253,513.912,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-06-30",3,2.53,100.23,,0,0.001,57.609,0.059,0.009,0.019,969.883,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-01",3,2.43,95.06,,0,0.0007,54.732,0.059,0.006,0.017,921.005,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-02",3,1.67,55.04,,0,0.001,32.659,0.059,0.005,0.019,549.382,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-03",4,2.11,68.23,,0,0.001,40.357,0.0593,0.006,0.0155,680.021,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-04",4,2.95,118.83,,0,0.0008,68.176,0.0593,0.012,0.0278,1147.142,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-05",7,5.59,149.78,,0.001,0.0009,93.629,0.0593,0.017,0.0236,1575.384,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-06",9,8.12,208.12,,0.001,0.0009,131.176,0.0593,0.008,0.0097,2207.284,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-07",6,5.03,147.83,,0,0.001,89.559,0.0593,0.008,0.0127,1506.553,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-08",12,11.8,501.4,,0.001,0.0008,284.9,0.0592,0.021,0.0095,4793.96,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-09",15,11.76,394.66,,0.001,0.0008,232.847,0.0593,0.019,0.0108,3917.92,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-10",4,3.05,103.3,,0,0.0005,61.286,0.0598,0.011,0.0255,1029.905,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-11",11,9.68,323.68,,0.001,0.0009,191.752,0.0595,0.021,0.0175,3223.972,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-12",8,7.42,252.28,,0.001,0.001,148.458,0.0594,0.011,0.0126,2498.406,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-13",7,4.33,112.05,,0,0.0009,69.375,0.0594,0.005,0.0171,1166.829,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-14",13,11.2,301.8,,0.001,0.0009,185.63,0.0595,0.01,0.0092,3122.84,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-17",7,5.16,140.6,,0.001,0.0009,86.804,0.0594,0.008,0.0137,1459.904,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-19",19,16.1,440.7,,0.002,0.0009,269.94,0.0593,0.019,0.0115,4541.92,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-22",1,0.88,32.56,,0,0.001,18.832,0.059,0.006,0.035,317.416,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-23",6,4.27,120.47,,0,0.001,73.105,0.0597,0.004,0.012,1227.774,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-27",9,5.63,147.58,,0.001,0.0007,91.487,0.0594,0.011,0.02,1540.037,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-29",10,6.63,205.07,,0.001,0.0009,122.86,0.0594,0.01,0.0159,2066.062,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-30",9,6.68,218.03,,0.001,0.0009,129.489,0.0597,0.013,0.0124,2176.211,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-07-31",16,13.55,352.63,,0.001,0.0009,220.851,0.0594,0.012,0.0106,3712.779,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-01",10,6.62,165.65,,0.001,0.0008,104.042,0.0593,0.01,0.0171,1751.459,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-03",16,14.43,454.47,,0.001,0.0009,272.253,0.0593,0.019,0.0106,4581.601,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-06",10,8.2,220.8,,0.001,0.0009,135.62,0.0592,0.009,0.0111,2284.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-09",13,11.18,316.62,,0.001,0.0008,192.598,0.0594,0.014,0.0106,3239.964,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-10",5,3.17,82.27,,0,0.0006,51.09,0.0596,0.005,0.0186,859.231,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-12",8,6.21,185.54,,0.001,0.0009,113.387,0.0593,0.014,0.023,1907.916,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-13",16,13.5,439.7,,0.001,0.0009,261.535,0.0593,0.016,0.0121,4402.168,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-14",13,11.74,473.1,,0.001,0.0008,269.944,0.0593,0.019,0.011,4541.374,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-15",13,12.85,508.11,,0.002,0.0009,292.064,0.0592,0.022,0.0094,4915.395,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-16",14,12.1,428.78,,0.001,0.0009,251.516,0.0594,0.024,0.0151,4231.468,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-17",16,14.35,527.26,,0.002,0.0009,307.997,0.0592,0.021,0.0097,5184.53,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-18",19,17.5,544.48,,0.002,0.0009,330.282,0.0593,0.023,0.0096,5557.28,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-19",22,17.51,481.43,,0.002,0.001,299.723,0.0594,0.019,0.0118,5041.496,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-20",12,7.98,195.84,,0.001,0.0008,125.068,0.0591,0.014,0.0195,2105.482,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-21",13,9.85,250.89,,0.001,0.0009,158.212,0.0591,0.012,0.0126,2665.227,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-22",8,6.45,180.3,,0.001,0.001,111.525,0.0594,0.009,0.0156,1877.685,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-23",4,2.18,54.78,,0,0.0008,34.452,0.0593,0.004,0.0213,579.748,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-24",8,6.28,173.42,,0.001,0.001,107.138,0.0593,0.006,0.0144,1802.576,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-25",8,5.3,139.1,,0.001,0.0008,86.67,0.0595,0.009,0.0181,1457.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-26",21,18.83,506.85,,0.002,0.001,312.926,0.0594,0.018,0.0086,5264.794,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-27",7,5.85,157.55,,0.001,0.001,97.36,0.0593,0.013,0.0223,1640.48,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-28",1,0.57,14.25,,0,0.001,9.12,0.06,0.004,0.046,153.216,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-29",19,16.4,440.65,,0.002,0.0009,273.464,0.0593,0.016,0.0101,4605.588,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-03",7,4.78,124.5,,0,0.0009,77.982,0.0596,0.008,0.0183,1311.472,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-04",3,2.1,53.1,,0,0.001,33.53,0.0593,0.002,0.0137,563.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-05",10,8.68,247.18,,0.001,0.001,152.72,0.0593,0.01,0.0115,2570.75,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-06",10,8.67,289.65,,0.001,0.0009,173.464,0.0593,0.013,0.011,2918.975,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-07",8,4.33,113.61,,0,0.0009,71.562,0.0595,0.008,0.0193,1204.357,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-08",7,4.05,99.79,,0,0.0009,63.993,0.0594,0.007,0.025,1076.877,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-09",5,2.07,47.94,,0,0.0008,30.82,0.0592,0.008,0.0346,518.622,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-10",4,2.28,56.06,,0,0.0008,35.964,0.0595,0.005,0.0213,604.104,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-11",6,2.95,71.65,,0,0.0005,45.874,0.0598,0.008,0.0263,770.254,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-12",4,2.68,69.14,,0,0.0008,43.878,0.0593,0.006,0.0263,738.414,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-14",4,2.23,54.22,,0,0.0008,34.407,0.0595,0.005,0.0203,578.973,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-15",3,1.33,31.85,,0,0.001,20.497,0.0593,0.003,0.0303,344.642,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-16",5,3.1,78.12,,0,0.0008,49.428,0.0596,0.006,0.014,830.43,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-17",5,3.81,109.55,,0,0.001,67.257,0.0592,0.007,0.0158,1132.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-22",4,2.45,61.94,,0,0.001,39.481,0.0593,0.005,0.0285,663.503,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-24",9,6.36,179.68,,0.001,0.001,109.982,0.0592,0.013,0.0204,1853.162,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-29",6,4.47,127.93,,0,0.0007,78.231,0.0593,0.007,0.0183,1317.274,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-09-30",5,3.19,87.43,,0,0.001,53.829,0.0594,0.007,0.019,907.181,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-01",8,5.75,164.7,,0.001,0.0009,101.734,0.0594,0.012,0.0195,1712.797,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-02",5,3.67,92.35,,0,0.001,59.203,0.059,0.009,0.0262,996.797,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-03",7,3.84,112.41,,0,0.001,69.281,0.0593,0.008,0.0184,1166.185,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-04",5,3.18,101.22,,0,0.001,60.382,0.0596,0.007,0.0186,1015.048,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-05",7,5.67,196.19,,0.001,0.001,113.838,0.0594,0.009,0.0137,1915.582,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-06",6,5.01,147.19,,0,0.001,88.984,0.0593,0.009,0.0145,1497.532,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-07",6,4.18,111.98,,0,0.0008,68.736,0.0592,0.006,0.0148,1157.656,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-10",4,2.43,87.44,,0,0.0008,49.971,0.0595,0.008,0.024,841.329,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-16",2,1.43,38.72,,0,0.001,24.112,0.059,0.005,0.0285,405.669,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-17",2,1.2,30.6,,0,0.0005,18.9,0.059,0.007,0.045,318.36,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-18",6,4.26,111.36,,0,0.001,68.506,0.0593,0.007,0.0153,1152.032,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-20",6,3.11,78.91,,0,0.0008,48.525,0.059,0.008,0.0247,816.567,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-21",3,1.11,28.29,,0,0.001,17.467,0.0593,0.007,0.029,294.607,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-22",3,1.43,34.48,,0,0.001,21.528,0.0593,0.004,0.034,362.316,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-23",6,4.9,132.39,,0,0.0008,79.921,0.0592,0.01,0.0213,1345.317,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-24",5,2.3,56.46,,0,0.0008,35.268,0.0596,0.004,0.0226,592.742,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-26",2,1.18,28.36,,0,0.0005,17.952,0.0595,0.01,0.062,301.872,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-28",3,1.18,28.08,,0,0.0007,17.574,0.0593,0.004,0.0273,295.88,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-29",3,1.95,51.97,,0,0.001,31.512,0.0593,0.007,0.0273,530.432,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-30",5,3.67,101.7,,0,0.0008,62.101,0.059,0.006,0.022,1045.312,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-01",4,2.88,96.92,,0,0.001,56.821,0.059,0.007,0.0138,957.184,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-02",8,6.18,159.98,,0.001,0.0009,99.032,0.0593,0.007,0.0129,1667.778,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-03",10,6.67,182.36,,0.001,0.0007,111.409,0.0594,0.011,0.0176,1875.293,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-04",9,7.45,245.96,,0.001,0.001,144.045,0.0592,0.01,0.0144,2423.925,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-05",8,6.9,185.9,,0.001,0.001,113.94,0.0593,0.009,0.0118,1918.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-06",6,4.45,112.1,,0,0.0007,68.47,0.0592,0.008,0.0182,1154.655,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-07",5,3.2,80,,0,0.0008,49.01,0.0594,0.005,0.0184,824.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-08",5,2.92,67.98,,0,0.0008,42.766,0.0594,0.008,0.0256,719.254,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-09",11,6.54,151.18,,0.001,0.0007,97.02,0.0593,0.016,0.03,1634.02,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-10",7,5.16,131.28,,0.001,0.001,81.344,0.0593,0.007,0.0146,1370.784,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-11",6,3.73,85.82,,0,0.0007,54.729,0.0595,0.009,0.0208,920.965,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-12",6,3.03,71.82,,0,0.0008,45.155,0.0595,0.008,0.024,759.203,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-13",7,5.63,135.84,,0,0.0006,85.402,0.0593,0.015,0.0269,1437.966,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-14",3,1.69,40.73,,0,0.001,25.108,0.0593,0.004,0.0257,422.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-15",7,5.43,164.12,,0.001,0.001,97.71,0.0591,0.008,0.0171,1644.393,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-16",9,5.38,129.58,,0.001,0.0009,81.564,0.0593,0.008,0.0176,1372.218,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-17",7,4.67,113.49,,0,0.0007,70.592,0.0591,0.012,0.0264,1187.991,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-18",7,5.22,131.84,,0.001,0.001,81.376,0.059,0.007,0.0146,1371.962,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-19",3,1.7,40.74,,0,0.001,25.474,0.0593,0.007,0.039,428.3,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-20",6,5,133.4,,0,0.0008,82.12,0.0592,0.008,0.0147,1381.67,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-23",3,1.93,46.94,,0,0.0007,29.944,0.059,0.006,0.0283,503.616,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-01",5,3.65,107.89,,0,0.0008,64.835,0.059,0.012,0.0248,1092.283,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-02",8,6.12,199.1,,0.001,0.0009,117.604,0.0593,0.018,0.0258,1979.557,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-03",6,5,134.16,,0,0.0008,82.795,0.059,0.008,0.0158,1395.407,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-04",11,9.37,361.75,,0.001,0.0009,206.576,0.059,0.018,0.0155,3478.947,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-05",9,7.2,197.8,,0.001,0.0009,121.16,0.0592,0.008,0.0114,2040.06,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-06",7,5.73,150.41,,0.001,0.0007,93.566,0.0591,0.008,0.0169,1575.072,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-07",13,9.9,299.45,,0.001,0.0008,178.693,0.0593,0.014,0.0135,3009.224,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-08",8,4.79,116.97,,0,0.0006,73.853,0.0591,0.008,0.0214,1244.48,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-09",10,6.76,169.8,,0.001,0.0009,105.896,0.0594,0.009,0.0195,1780.562,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-10",11,8.04,225.66,,0.001,0.0007,136.998,0.0593,0.011,0.0148,2306.986,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-11",14,11.15,343.95,,0.001,0.0008,205.095,0.0592,0.015,0.0125,3453.48,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-12",8,7.2,293.7,,0.001,0.0009,166.37,0.0593,0.013,0.0146,2799.08,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-14",12,8.9,227.63,,0.001,0.0008,141.824,0.0593,0.012,0.016,2386.839,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-15",7,6.2,220.2,,0.001,0.0009,126.92,0.059,0.009,0.0111,2136.22,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-16",13,10.38,370.54,,0.001,0.0009,213.55,0.0592,0.013,0.0101,3593.32,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-17",2,1.13,25.32,,0,0.0005,16.329,0.0595,0.007,0.0505,274.743,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-18",5,4,125.4,,0,0.0008,74.315,0.059,0.013,0.0252,1251.185,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-21",3,1.39,37.5,,0,0.001,23.158,0.0597,0.004,0.0367,389.829,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-22",7,3.9,98,,0,0.0009,61.31,0.0593,0.009,0.0227,1031.13,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-28",5,2.65,61.1,,0,0.0006,39.04,0.0596,0.011,0.0354,656.11,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-30",7,3.92,98.18,,0,0.0009,61.062,0.0593,0.009,0.0221,1028.436,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-02",3,2.23,54.05,,0,0.001,33.442,0.059,0.008,0.0267,563.559,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-13",2,1.25,30.78,,0,0.001,19.265,0.059,0.006,0.0435,323.927,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-15",3,1.51,35.55,,0,0.0007,22.369,0.059,0.004,0.0297,376.745,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-16",2,1.2,29.6,,0,0.0005,18.504,0.059,0.007,0.0395,312.14,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-17",2,1.28,38.85,,0,0.001,23.386,0.059,0.007,0.045,393.262,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-29",6,3.65,88.85,,0,0.0008,55.908,0.0595,0.01,0.0317,939.473,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-30",3,1.68,39.17,,0,0.001,25.057,0.0597,0.007,0.0363,421.242,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-02",2,1.17,26.85,,0,0.0005,16.998,0.0595,0.005,0.031,285.663,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-04",10,8.64,227.47,,0.001,0.0008,139.942,0.0594,0.018,0.0175,2353.874,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-05",13,12.06,589.21,,0.002,0.001,325.037,0.0592,0.025,0.0105,5469.748,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-06",9,8.08,221.56,,0.001,0.0009,132.824,0.0592,0.013,0.0147,2235.924,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-10",3,1.68,45.06,,0,0.001,27.712,0.0597,0.006,0.0403,465.588,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-13",5,3.17,84.55,,0,0.0008,51.789,0.0592,0.012,0.0322,871.702,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-14",5,3.16,89.57,,0,0.0008,54.071,0.0594,0.011,0.0252,909.386,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-21",2,1.17,26.85,,0,0.0005,17.085,0.059,0.005,0.0345,287.73,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-24",7,4.65,125.19,,0,0.0007,76.658,0.0593,0.012,0.0304,1290.095,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-25",5,3.18,75.9,,0,0.0006,48.029,0.0596,0.014,0.0418,807.908,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-26",2,1.2,27.09,,0,0.0005,17.202,0.059,0.007,0.048,289.662,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-27",3,1.69,39.95,,0,0.0007,24.936,0.0593,0.008,0.0413,419.11,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-01",2,0.82,18.42,,0,0.0005,11.938,0.06,0.008,0.0745,200.433,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-08",2,1.12,34.07,,0,0.001,20.648,0.059,0.012,0.0625,347.544,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-10",4,2.97,106.57,,0,0.001,61.608,0.0593,0.01,0.0298,1037.058,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-11",6,3.9,141.66,,0,0.0008,81.305,0.059,0.019,0.0328,1368.42,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-12",5,2.37,85.59,,0,0.0006,49.677,0.059,0.011,0.0274,836.49,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-13",9,7.45,299.09,,0.001,0.001,169.422,0.0591,0.022,0.0217,2850.46,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-14",9,6.71,283.02,,0.001,0.0009,159.249,0.0593,0.017,0.0169,2679.334,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-15",3,1.96,83.36,,0,0,46.636,0.059,0.007,0.0193,785.592,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-16",4,2.31,61.88,,0,0.0008,37.344,0.059,0.01,0.033,629.298,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-17",2,1.18,27.88,,0,0.0005,17.205,0.06,0.005,0.0335,289.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-30",2,1.2,27.34,,0,0,17.348,0.059,0.012,0.086,292.318,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-02",2,1.45,53.9,,0,0.001,30.915,0.059,0.008,0.0335,520.415,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-03",5,3.56,106.2,,0,0.0008,63.484,0.0592,0.008,0.0172,1068.192,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-06",4,2.22,53.26,,0,0.0005,33.066,0.0598,0.005,0.023,555.068,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-07",6,3.81,92.54,,0,0.0008,57.437,0.0593,0.014,0.0322,967.363,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-08",3,1.7,40.1,,0,0.001,25.54,0.0593,0.004,0.0237,429.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-14",4,2.95,73,,0,0.0008,45.04,0.0595,0.006,0.0268,757.755,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-16",2,1.72,55.08,,0,0.001,32.097,0.059,0.006,0.022,539.625,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-17",2,1.68,40.34,,0,0.0005,25.461,0.0595,0.008,0.038,427.967,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-23",4,2.72,72.87,,0,0.001,44.53,0.059,0.006,0.0265,750.111,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-24",4,2.69,75.45,,0,0.0008,45.733,0.059,0.007,0.029,769.474,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-27",9,7.16,183.44,,0.001,0.0009,114.492,0.0593,0.009,0.012,1925.288,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-28",4,2.43,61.18,,0,0.001,38.159,0.0595,0.005,0.0275,642.392,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-29",4,2.18,53.88,,0,0.0008,33.494,0.0593,0.006,0.0228,564.252,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-05",4,2.7,69.5,,0,0.0008,42.925,0.0593,0.005,0.0238,723.54,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-06",4,2.35,58.1,,0,0.001,35.83,0.059,0.003,0.0228,604.14,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-07",5,3.45,89.45,,0,0.0006,55.29,0.0592,0.007,0.0192,931.615,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-08",7,4.99,126.24,,0,0.0006,77.962,0.0594,0.012,0.0233,1310.888,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-11",2,1.43,49.68,,0,0.001,28.83,0.059,0.011,0.053,485.774,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-15",2,1.43,33.43,,0,0.0005,21.206,0.06,0.008,0.038,356.158,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-16",5,3.68,89.48,,0,0.001,56.076,0.0594,0.008,0.0244,943.192,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-18",21,19.27,516.96,,0.002,0.001,313.728,0.0592,0.016,0.0074,5281.318,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-26",9,7.88,284.28,,0.001,0.0009,166.758,0.0592,0.013,0.015,2806.782,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-27",3,1.17,43.07,,0,0.0003,24.893,0.0593,0.003,0.023,419.016,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-28",6,2.37,56.13,,0,0.0005,35.618,0.0595,0.005,0.0232,598.797,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-29",2,1.2,27.06,,0,0.0005,17.552,0.059,0.005,0.0355,295.984,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-02",6,2.85,66.35,,0,0.0007,42.147,0.0597,0.007,0.0237,709.278,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-03",9,7.45,211.85,,0.001,0.001,127.915,0.0593,0.009,0.014,2151.99,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-04",6,5.2,136.2,,0,0.0008,83.54,0.0595,0.011,0.021,1404.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-05",4,2.23,52.57,,0,0.0008,33.264,0.059,0.006,0.022,560.016,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-08",6,4.43,116.87,,0,0.0008,71.836,0.0595,0.009,0.0198,1208.829,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-09",5,4.4,123.74,,0,0.001,75.562,0.0594,0.008,0.0158,1270.231,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-10",9,6.9,227.1,,0.001,0.0009,133.35,0.0592,0.012,0.0152,2244.54,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-11",5,3.7,113.6,,0,0.0008,66.91,0.0596,0.007,0.0154,1125.46,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-14",3,1.15,27.06,,0,0.001,17.173,0.0593,0.004,0.0197,289.697,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-17",4,2.18,55.46,,0,0.0005,34.204,0.059,0.005,0.02,576.326,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-18",5,3.22,83.16,,0,0.0008,51.758,0.0592,0.008,0.0208,870.174,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-20",1,0.83,21.58,,0,0.001,13.28,0.06,0.006,0.058,222.938,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-21",1,0.12,0.36,,0,0.001,0.696,0.06,0,0.023,11.688,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-22",5,3.2,84.1,,0,0.0008,52.26,0.059,0.006,0.0174,880.53,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-23",4,2.85,73.24,,0,0.001,46.033,0.059,0.005,0.015,774.548,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-24",5,3.41,88.3,,0,0.0006,55.124,0.0594,0.008,0.0186,927.574,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-25",10,7.33,203.37,,0.001,0.0008,123.906,0.0594,0.011,0.0131,2085.529,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-26",7,5.68,161.28,,0.001,0.001,97.944,0.0596,0.009,0.0144,1646.076,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-27",3,2.68,105.86,,0,0.001,60.134,0.059,0.008,0.017,1012.235,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-29",3,1.96,48.96,,0,0.001,30.04,0.0593,0.007,0.0263,505.696,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-06-30",3,2.53,100.23,,0,0.001,56.818,0.059,0.01,0.0207,956.985,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-01",3,2.43,95.06,,0,0.0007,54.061,0.059,0.006,0.0173,909.627,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-02",3,1.67,55.04,,0,0.001,32.288,0.0593,0.005,0.018,543.385,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-03",4,2.11,67.23,,0,0.001,39.746,0.0598,0.008,0.0178,668.391,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-04",4,2.93,117.67,,0,0.0008,66.429,0.059,0.013,0.0315,1118.753,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-05",6,4.67,114.72,,0,0.0008,72.767,0.0597,0.011,0.0202,1222.721,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-06",16,15.11,563.15,,0.002,0.0009,324.2,0.0593,0.022,0.0091,5456.957,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-07",17,15.32,472.16,,0.002,0.0009,281.188,0.0594,0.017,0.0109,4729.006,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-08",13,12.05,318.85,,0.001,0.001,197.135,0.0593,0.016,0.0104,3316.645,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-09",5,3.6,95.65,,0,0.001,58.21,0.0596,0.006,0.0194,978.155,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-10",6,3.55,116.68,,0,0.0003,68.517,0.0592,0.012,0.026,1153.979,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-11",13,10.75,341.55,,0.001,0.0009,202.893,0.0593,0.021,0.0171,3414.103,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-12",8,5.95,198.19,,0.001,0.001,115.859,0.0594,0.016,0.0244,1948.571,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-13",17,13.34,354.96,,0.001,0.0009,215.549,0.0593,0.011,0.0098,3627.22,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-14",1,0.4,10,,0,0.001,6.12,0.06,0.004,0.078,102.68,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-15",13,10.3,277.77,,0.001,0.0008,167.904,0.0593,0.01,0.0105,2824.394,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-16",1,0.98,26.46,,0,0.001,15.876,0.059,0.006,0.043,267.736,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-17",1,0.17,1.7,,0,0.001,1.53,0.059,0,0.005,25.772,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-20",5,3.18,76.78,,0,0.0008,48.054,0.0596,0.006,0.0168,808.358,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-21",1,0.97,29.1,,0,0.001,17.072,0.06,0.007,0.047,286.635,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-22",7,4.26,114.7,,0,0.0009,70.166,0.059,0.006,0.015,1181.722,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-27",5,3.45,88.9,,0,0.0008,54.795,0.059,0.008,0.0216,922.67,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-29",7,5.43,166.83,,0.001,0.001,99.327,0.0593,0.008,0.0176,1671.147,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-30",6,4.72,165.36,,0.001,0.0007,95.22,0.0592,0.008,0.0135,1602.752,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-07-31",5,3.43,89.27,,0,0.0006,55.154,0.0592,0.007,0.019,928.648,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-01",6,4.42,110.35,,0,0.0007,68.611,0.0593,0.009,0.0202,1154.201,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-02",7,4.72,123.12,,0,0.0007,75.792,0.0591,0.007,0.0176,1275.548,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-03",5,3.93,107.73,,0,0.0008,65.681,0.059,0.012,0.03,1106.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-04",4,2.13,51.53,,0,0.001,32.241,0.0595,0.004,0.0153,542.546,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-05",11,9.13,234.37,,0.001,0.001,142.497,0.0593,0.01,0.01,2398.883,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-08",19,17.15,493.1,,0.002,0.0009,297.324,0.0592,0.019,0.0091,5006.253,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-09",1,0.02,0.02,,0,0,0.068,0.059,0,0,1.15,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-10",5,3.18,82.28,,0,0.0006,50.376,0.0596,0.006,0.0176,846.404,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-11",7,5.68,149.76,,0.001,0.0007,92.74,0.0591,0.008,0.0139,1561.728,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-12",7,5.95,184.44,,0.001,0.0009,109.849,0.0593,0.015,0.0241,1847.95,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-13",8,7.7,266.65,,0.001,0.001,155.948,0.0591,0.015,0.013,2624.934,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-14",15,12.92,491.46,,0.001,0.0008,280.636,0.0593,0.023,0.0137,4724.254,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-15",13,12.85,479.63,,0.001,0.0009,275.889,0.0592,0.022,0.0098,4640.682,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-16",14,12.12,430.44,,0.001,0.001,250.566,0.0592,0.025,0.0154,4217.422,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-17",17,15.92,589.95,,0.002,0.0009,340.038,0.0591,0.022,0.0088,5723.726,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-18",19,17.51,543.19,,0.002,0.0009,326.341,0.0594,0.024,0.01,5488.942,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-19",22,17.53,477.37,,0.002,0.0009,293.794,0.0593,0.02,0.0115,4945.069,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-20",12,8.36,217.66,,0.001,0.0009,134.328,0.0593,0.012,0.0157,2260.684,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-21",13,9.85,257.97,,0.001,0.0009,158.343,0.0594,0.012,0.0124,2662.295,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-22",8,6.45,180.3,,0.001,0.001,110.145,0.0593,0.009,0.0173,1855.41,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-23",7,3.4,96.52,,0,0.0009,58.458,0.0591,0.007,0.0213,984.678,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-24",8,6.2,180.2,,0.001,0.0009,108.41,0.0598,0.009,0.014,1822.71,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-25",6,4.2,110.2,,0,0.0008,67.71,0.0592,0.008,0.018,1140.08,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-26",8,6.73,178.25,,0.001,0.001,109.07,0.0594,0.013,0.0188,1835.043,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-27",6,4.5,117.5,,0,0.0008,72.525,0.0595,0.006,0.0195,1218.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-29",7,4.44,114.98,,0,0.0007,70.865,0.0593,0.006,0.0216,1192.115,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-30",24,24,648,,0.002,0.001,397.7,0.0593,0.021,0.0062,6695,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-08-31",21,19.17,509.69,,0.002,0.0009,312.602,0.0591,0.019,0.0091,5265.532,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-01",23,21.15,567.2,,0.002,0.001,348.007,0.0592,0.019,0.0078,5857.683,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-02",23,21.2,568,,0.002,0.001,348.71,0.0592,0.018,0.008,5871.47,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-03",6,3.78,95.7,,0,0.001,59.576,0.0593,0.006,0.0188,1002.89,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-04",1,0.1,1.9,,0,0,1.28,0.06,0,0.031,21.5,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-05",13,10.78,293.86,,0.001,0.001,181.004,0.0593,0.017,0.0142,3046.718,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-06",10,8.67,289.72,,0.001,0.0009,171.532,0.0593,0.014,0.0112,2885.779,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-07",8,4.96,144.2,,0,0.0008,88.166,0.0593,0.009,0.0171,1484.242,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-08",7,4.04,99.54,,0,0.0009,63.36,0.0596,0.007,0.026,1064.518,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-09",15,11.38,300.06,,0.001,0.0009,185.644,0.0593,0.01,0.0119,3122.48,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-10",4,2.28,56.06,,0,0.0008,35.574,0.0595,0.006,0.0218,598.944,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-11",6,3.33,85.23,,0,0.0005,52.863,0.0595,0.015,0.0335,889.029,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-12",4,2.68,69.84,,0,0.0008,43.792,0.0595,0.007,0.0278,736.371,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-14",4,2.23,54.22,,0,0.0008,33.984,0.0593,0.005,0.0188,571.52,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-15",4,2.41,64.64,,0,0.001,39.729,0.059,0.006,0.0285,669.388,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-16",5,3.12,81.16,,0,0.001,50.33,0.059,0.006,0.0136,847.108,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-17",5,3.42,89.1,,0,0.001,55.302,0.0596,0.005,0.0208,929.07,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-24",4,3.9,114.21,,0,0.001,69.094,0.0593,0.01,0.0173,1162.496,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-01",9,6.16,176.08,,0.001,0.0009,108.098,0.0591,0.012,0.0204,1820.252,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-02",8,4.84,119.29,,0,0.001,76.289,0.0593,0.009,0.0184,1284.11,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-03",4,2.68,74.18,,0,0.001,45.652,0.059,0.006,0.0218,768.236,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-04",5,3.17,99.29,,0,0.0008,59.066,0.0594,0.007,0.0188,993.626,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-05",7,5.62,193.38,,0.001,0.0009,111.856,0.0591,0.011,0.0159,1883,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-06",6,5.01,144.26,,0,0.001,87.497,0.0592,0.009,0.015,1474.08,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-07",4,2.53,64.78,,0,0.001,39.681,0.0595,0.006,0.0248,667.795,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-10",4,2.43,87.87,,0,0.0008,50.004,0.0593,0.009,0.022,840.821,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-16",2,1.41,38.61,,0,0.001,23.605,0.059,0.005,0.0295,397.864,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-17",2,1.2,28.8,,0,0.0005,17.82,0.06,0.008,0.049,299.16,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-19",9,5.33,132.87,,0.001,0.0009,82.087,0.0597,0.008,0.0169,1380.746,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-21",3,1.11,26.29,,0,0.001,16.365,0.059,0.006,0.0267,275.389,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-22",7,3.86,100.06,,0,0.0009,60.792,0.0593,0.009,0.0234,1023.208,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-23",3,2.55,69.01,,0,0.0007,41.264,0.0593,0.007,0.0217,693.874,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-26",2,1.18,27.76,,0,0.0005,17.714,0.0595,0.01,0.0645,297.54,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-27",7,4.14,109.2,,0,0.0009,66.388,0.0591,0.012,0.0233,1118.354,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-29",3,1.95,51.14,,0,0.001,31.305,0.059,0.007,0.0277,527.067,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-30",5,3.67,101.7,,0,0.0008,61.664,0.0592,0.007,0.0234,1037.516,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-01",4,2.88,87.95,,0,0.001,52.148,0.0595,0.007,0.0138,876.063,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-02",6,4.6,116.56,,0,0.001,71.624,0.0593,0.007,0.0162,1205.972,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-03",5,4.14,118.38,,0,0.0008,71.324,0.0596,0.009,0.0174,1198.647,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-04",8,4.81,155.29,,0,0.0009,90.871,0.059,0.01,0.0208,1529.783,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-05",8,6.9,184.9,,0.001,0.001,113.08,0.0593,0.009,0.0116,1903.52,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-06",10,6.63,165.08,,0.001,0.0007,101.001,0.0592,0.012,0.0179,1699.471,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-07",5,3.2,80.1,,0,0.0008,48.61,0.0592,0.005,0.0176,818.64,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-08",5,2.87,66.18,,0,0.0008,41.791,0.0596,0.009,0.0274,702.892,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-09",11,7.63,217.11,,0.001,0.001,130.356,0.0595,0.013,0.0183,2193.935,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-10",5,3.43,83.48,,0,0.0008,51.796,0.0592,0.005,0.0228,873.18,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-11",7,4.07,98.22,,0,0.0007,61.347,0.0594,0.008,0.0204,1031.342,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-12",6,3.03,71.89,,0,0.0008,44.781,0.0593,0.008,0.0232,754.262,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-13",7,5.67,136.53,,0,0.0004,84.934,0.059,0.016,0.0301,1430.488,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-14",3,1.69,40.73,,0,0.001,24.951,0.059,0.005,0.026,420.294,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-15",7,4.81,137.84,,0,0.0009,82.306,0.0593,0.008,0.0201,1385.594,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-16",9,5.38,128.58,,0.001,0.0009,81.076,0.0594,0.009,0.018,1363.358,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-17",7,4.69,113.12,,0,0.0007,70.254,0.0596,0.013,0.0276,1180.169,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-18",7,5.22,131.94,,0.001,0.0009,80.896,0.0593,0.008,0.0154,1360.22,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-01",5,3.67,107.71,,0,0.0008,64.15,0.0592,0.012,0.0252,1079.585,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-02",8,6.12,190.1,,0.001,0.0009,111.937,0.0593,0.015,0.0213,1882.547,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-03",7,4.63,127.95,,0,0.001,77.172,0.059,0.013,0.0213,1300.286,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-04",11,9.37,354.1,,0.001,0.0008,201.484,0.0593,0.019,0.0165,3391.635,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-05",9,7.2,198.8,,0.001,0.001,120.73,0.0596,0.008,0.0107,2031.32,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-06",7,5.73,143.89,,0.001,0.0007,89.874,0.0594,0.009,0.0196,1511.883,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-07",13,9.9,275.52,,0.001,0.001,167.506,0.0594,0.015,0.0138,2818.238,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-08",8,4.81,116.99,,0,0.0005,73.448,0.059,0.008,0.0205,1236.903,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-09",12,8.64,221.98,,0.001,0.0009,136.468,0.0593,0.014,0.0181,2299.242,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-10",13,9.86,272.1,,0.001,0.0007,165.74,0.0593,0.012,0.0128,2788.586,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-11",12,9.78,304.23,,0.001,0.0009,179.576,0.0592,0.017,0.0141,3021.609,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-12",8,7.2,291.7,,0.001,0.0009,163.45,0.0591,0.013,0.016,2751.78,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-15",4,2.68,72.58,,0,0.0008,44.056,0.0593,0.006,0.021,741.446,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-16",13,10.34,364.73,,0.001,0.0009,209.556,0.0593,0.015,0.0102,3524.394,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-17",2,1.2,27,,0,0,16.98,0.0595,0.008,0.0515,285.66,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-22",3,1.37,32.99,,0,0.0007,20.625,0.0593,0.004,0.038,346.964,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-23",2,1.2,27.54,,0,0.0005,17.484,0.0595,0.009,0.0595,294.27,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-24",6,2.42,56.28,,0,0.0007,35.268,0.0597,0.004,0.0202,592.426,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-28",2,1.45,34.55,,0,0.0005,21.36,0.0595,0.009,0.055,358.875,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-29",5,2.47,58.93,,0,0.0006,37.12,0.0596,0.008,0.027,623.63,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-30",4,2.7,68.1,,0,0.001,42.08,0.0593,0.01,0.0358,709.02,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-2",,"2020-12-31",3,2.33,55.94,,0,0.0007,35.325,0.059,0.006,0.0227,594.932,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-02",3,2.21,54.01,,0,0.0007,33.317,0.0593,0.009,0.0313,560.592,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-13",2,1.25,32.03,,0,0.001,19.562,0.059,0.006,0.044,329.007,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-15",3,1.5,35.31,,0,0.001,22.218,0.0597,0.005,0.0333,373.383,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-16",2,1.2,30,,0,0.001,18.57,0.06,0.007,0.0385,311.79,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-17",2,0.85,16.65,,0,0,11.135,0.0595,0.004,0.05,187.055,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-18",2,0.87,18.53,,0,0.0005,12.023,0.059,0.006,0.0595,202.893,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-19",2,0.96,22.35,,0,0.001,14.022,0.0595,0.007,0.039,235.572,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-29",6,3.65,88.85,,0,0.0005,55.273,0.0593,0.011,0.0335,930.409,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-30",3,1.68,39.8,,0,0.001,25.157,0.0597,0.008,0.0403,422.65,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-02",2,1.17,26.85,,0,0.0005,17.028,0.0595,0.005,0.0325,285.915,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-04",3,2.07,54.43,,0,0.0007,32.897,0.059,0.007,0.0283,553.878,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-10",7,4.93,130.49,,0,0.0009,80.05,0.0593,0.014,0.0271,1346.881,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-11",12,11.13,546.64,,0.002,0.001,300.956,0.0593,0.023,0.0098,5062.265,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-13",2,1.24,28.52,,0,0.0005,17.794,0.059,0.006,0.037,299.46,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-14",5,3.13,85.61,,0,0.0008,51.423,0.0592,0.012,0.0288,866.198,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-21",2,1.17,27.15,,0,0.0005,17.175,0.0595,0.008,0.0425,289.278,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-24",7,4.65,125.57,,0,0.0007,76.428,0.0593,0.014,0.0349,1286.417,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-25",10,9.45,290.75,,0.001,0.0009,172.535,0.0594,0.017,0.0129,2903.55,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-26",2,1.2,32.9,,0,0.001,19.806,0.059,0.009,0.0545,333.486,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-27",3,1.68,40.08,,0,0.001,25.004,0.0593,0.008,0.0427,421.072,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-01",3,2.2,56.6,,0,0.0007,34.88,0.0597,0.012,0.0457,586.24,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-03",3,1.43,43.74,,0,0.0003,26.045,0.059,0.005,0.0177,438.988,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-04",2,1.18,28.89,,0,0.0005,18.079,0.0595,0.007,0.0385,303.576,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-10",3,1.69,39.95,,0,0.0007,24.898,0.0593,0.008,0.041,419.384,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-11",2,1.3,56,,0,0.0005,31.37,0.0595,0.011,0.0435,527.34,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-12",5,2.32,83.9,,0,0.0008,48.271,0.0594,0.012,0.0262,811.784,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-13",9,7.45,278.48,,0.001,0.001,158.729,0.0591,0.019,0.0187,2671.452,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-14",9,6.71,276.16,,0.001,0.0008,155.218,0.0592,0.018,0.0178,2611.357,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-15",3,1.93,68.64,,0,0.0007,39.935,0.059,0.007,0.0207,671.946,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-16",4,2.31,60.69,,0,0.0008,36.533,0.0593,0.01,0.0328,615.105,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-17",2,1.18,27.88,,0,0.0005,17.323,0.0595,0.005,0.031,290.947,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-29",2,0.32,10.04,,0,0.0005,5.728,0.059,0.005,0.0595,96.466,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-03",1,0.83,19.09,,0,0,12.201,0.059,0.002,0.019,205.591,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-06",4,2.2,53.48,,0,0.0008,33.16,0.0593,0.005,0.0228,557.436,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-07",6,3.83,93.9,,0,0.0008,57.699,0.0592,0.014,0.0312,971.876,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-08",3,1.7,40.1,,0,0.001,25.71,0.0593,0.005,0.0243,432.53,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-14",4,2.95,73,,0,0.0008,45.325,0.0593,0.007,0.0278,762.865,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-16",2,1.72,55.08,,0,0.001,32.443,0.059,0.006,0.0235,546.284,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-17",2,1.68,40.34,,0,0.001,25.712,0.0595,0.008,0.0375,432.07,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-23",4,2.68,68.34,,0,0.0008,41.978,0.059,0.006,0.03,707.16,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-24",4,2.67,76.41,,0,0.0008,46.204,0.0593,0.008,0.032,777.618,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-28",4,2.43,62.18,,0,0.001,38.61,0.0595,0.006,0.0315,648.967,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-29",4,2.2,53.9,,0,0.0008,33.78,0.0593,0.006,0.0228,567.92,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-04-30",1,0.98,27.44,,0,0.001,16.66,0.059,0.005,0.035,280.28,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-01",9,6.28,168.38,,0.001,0.0009,103.324,0.0593,0.007,0.0139,1738.188,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-05",4,2.7,69.15,,0,0.0008,42.98,0.0593,0.006,0.0263,723.115,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-06",4,2.35,57.85,,0,0.0008,36.09,0.059,0.004,0.0258,608.02,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-07",5,3.45,89.35,,0,0.0006,55.505,0.0596,0.007,0.0202,933.61,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-08",7,4.99,126.91,,0,0.0006,78.858,0.0594,0.011,0.0207,1326.541,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-11",2,1.41,53.91,,0,0.001,30.812,0.06,0.008,0.033,517.708,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-15",2,1.43,34.28,,0,0.0005,21.407,0.059,0.008,0.039,361.005,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-16",5,3.68,91.48,,0,0.001,56.576,0.0594,0.009,0.0246,950.708,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-20",12,11.12,288.16,,0.001,0.0009,180.288,0.0591,0.013,0.0108,3034.692,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-21",20,17.33,457.75,,0.002,0.001,282.295,0.0595,0.016,0.0094,4748.816,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-26",9,7.88,306.1,,0.001,0.001,174.994,0.0591,0.014,0.015,2944.846,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-27",3,1.17,43.17,,0,0.0007,25.23,0.0593,0.004,0.021,424.382,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-28",6,2.36,55.9,,0,0.0007,35.326,0.0593,0.005,0.0218,594.142,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-29",2,1.2,28.26,,0,0.0005,17.846,0.0595,0.005,0.0345,300.184,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-02",6,2.86,69.96,,0,0.0008,43.97,0.0595,0.008,0.024,738.53,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-03",9,7.45,217.2,,0.001,0.001,130.32,0.0592,0.01,0.0146,2193.39,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-04",6,5.2,136.8,,0,0.0008,84.9,0.0593,0.012,0.0225,1428.02,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-05",4,2.23,54.49,,0,0.0008,33.67,0.06,0.006,0.0215,565.326,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-08",6,4.41,118.87,,0,0.0007,72.394,0.0595,0.009,0.0193,1217.262,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-09",5,4.4,124.57,,0,0.001,75.942,0.0596,0.008,0.016,1275.425,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-10",9,6.9,229.1,,0.001,0.0008,134.88,0.0596,0.013,0.0148,2268.42,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-11",5,3.7,111.1,,0,0.0008,65.75,0.0592,0.006,0.015,1106.79,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-17",4,2.16,53.36,,0,0.001,33.34,0.0595,0.004,0.0188,560.784,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-18",5,3.22,80.06,,0,0.0008,50.44,0.0596,0.008,0.0208,848.72,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-19",3,1.26,30.6,,0,0.0007,19.378,0.0593,0.005,0.025,325.832,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-22",13,9.33,250.34,,0.001,0.0009,154.775,0.0592,0.013,0.0133,2605.071,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-23",4,2.85,75.24,,0,0.001,46.524,0.059,0.005,0.016,782.957,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-24",5,3.4,91.46,,0,0.0008,55.939,0.0594,0.009,0.0188,942.14,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-25",5,3.2,85.84,,0,0.0008,52.224,0.0596,0.008,0.0194,879.484,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-26",13,9.86,289.27,,0.001,0.001,173.745,0.0595,0.017,0.0126,2922.275,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-27",3,2.68,111.54,,0,0.001,62.823,0.0593,0.014,0.0293,1056.863,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-29",3,1.95,48.7,,0,0.001,29.891,0.0593,0.007,0.0273,502.804,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-06-30",3,2.51,100.96,,0,0.001,57.376,0.0593,0.01,0.02,965.348,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-01",3,2.43,96.91,,0,0.0007,55.002,0.0593,0.006,0.0163,925.267,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-02",3,1.67,56.14,,0,0.001,32.612,0.059,0.005,0.0207,549.715,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-03",4,2.11,69.2,,0,0.0008,41.15,0.0595,0.007,0.0158,691.865,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-04",4,2.95,121.7,,0,0.0008,68.525,0.0593,0.013,0.0293,1153.675,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-05",6,4.69,130.74,,0,0.001,79.989,0.0595,0.014,0.0242,1345.493,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-06",6,4.2,113.68,,0,0.0008,69.332,0.0595,0.007,0.0155,1165.84,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-07",4,2.17,52.22,,0,0.001,32.935,0.0593,0.004,0.0168,553.863,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-08",6,4.24,110.76,,0,0.0008,68.48,0.0593,0.007,0.0167,1150.988,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-09",7,4.74,125.01,,0,0.0009,76.778,0.0591,0.007,0.0186,1292.559,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-10",13,11,421.75,,0.001,0.001,241.795,0.0592,0.018,0.0106,4068.318,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-11",9,7.68,242.48,,0.001,0.001,143.86,0.0596,0.015,0.0169,2418.76,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-12",5,4.23,164.92,,0,0.001,94.382,0.0592,0.01,0.02,1587.669,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-13",4,2.12,52.42,,0,0.0005,32.554,0.0598,0.011,0.0403,546.686,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-14",3,2.1,53.1,,0,0.001,32.72,0.0593,0.001,0.0103,549.85,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-16",12,11.08,299.22,,0.001,0.001,183.092,0.0593,0.013,0.01,3081.752,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-17",2,1.07,26.84,,0,0.001,16.993,0.059,0.003,0.0195,286.204,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-18",10,7.27,198.04,,0.001,0.001,122.066,0.0595,0.01,0.0129,2051.984,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-21",5,3.86,96.58,,0,0.001,59.64,0.0592,0.007,0.0172,1004.118,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-24",19,16.28,443.08,,0.002,0.0009,268.386,0.0594,0.018,0.0107,4515.384,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-25",24,24,644,,0.002,0.001,393.2,0.0593,0.019,0.0057,6614.1,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-26",1,0.62,13.64,,0,0,8.742,0.059,0.001,0.016,147.002,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-27",6,4.32,111.42,,0,0.0008,69.13,0.0592,0.01,0.022,1165.153,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-28",2,1.1,27.1,,0,0.001,16.82,0.06,0.001,0.014,282.33,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-29",7,5.43,172.83,,0.001,0.001,102.297,0.0591,0.008,0.0164,1721.721,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-30",6,4.72,167.48,,0.001,0.0007,96.964,0.0592,0.008,0.0123,1632.368,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-07-31",8,5.5,139.22,,0.001,0.0008,86.397,0.0591,0.009,0.0158,1455.679,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-01",8,5.55,138.53,,0.001,0.0008,86.22,0.0591,0.009,0.0174,1452.037,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-03",4,2.93,78.31,,0,0.0008,47.457,0.0595,0.011,0.0368,798.374,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-07",5,3.18,78.88,,0,0.0008,49.268,0.059,0.006,0.0196,830.584,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-10",17,13.36,393.76,,0.001,0.0009,234.14,0.0594,0.018,0.0132,3941.858,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-11",4,3.07,82.19,,0,0.0008,49.94,0.0593,0.006,0.0155,840.784,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-12",11,8.55,248.72,,0.001,0.0008,150.355,0.0592,0.012,0.0143,2530.022,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-13",11,9.93,339.88,,0.001,0.001,198.397,0.0593,0.017,0.0123,3336.583,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-14",10,8.19,332.34,,0.001,0.0007,187.927,0.0592,0.014,0.0135,3162.81,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-15",21,19.93,702.06,,0.002,0.001,407.349,0.0594,0.026,0.008,6851.885,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-16",14,12.12,433.44,,0.001,0.001,252.576,0.0592,0.026,0.0156,4250.094,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-17",17,15.92,566.95,,0.002,0.0009,330.622,0.0593,0.023,0.0092,5561.466,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-18",19,17.5,527.68,,0.002,0.001,317.894,0.0593,0.024,0.0099,5349.446,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-19",22,17.48,479.82,,0.002,0.001,293.341,0.0591,0.02,0.0112,4935.247,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-20",12,8.36,221.58,,0.001,0.0008,136.124,0.0593,0.014,0.0164,2292.13,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-21",13,9.85,257.89,,0.001,0.0009,160.081,0.0595,0.013,0.0124,2692.05,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-22",8,6.07,165.56,,0.001,0.0009,101.456,0.0591,0.014,0.0251,1707.437,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-23",7,3.4,97.22,,0,0.0007,58.89,0.0594,0.008,0.0219,990.14,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-24",8,6.2,182.1,,0.001,0.0009,109.08,0.0593,0.009,0.0135,1835.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-25",6,4.2,111.2,,0,0.0008,68.72,0.0595,0.009,0.0187,1155.82,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-26",10,7.98,211,,0.001,0.0009,129.718,0.0593,0.011,0.0166,2181.978,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-27",21,17.16,460.86,,0.002,0.001,281.171,0.0592,0.019,0.0107,4732.242,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-29",5,3.69,98.19,,0,0.0008,60.201,0.0594,0.009,0.024,1012.659,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-03",4,2.43,60.35,,0,0.001,37.821,0.059,0.006,0.0295,637.6,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-05",13,11.18,328.62,,0.001,0.0009,199.198,0.059,0.016,0.0118,3354.448,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-06",10,8.67,290.72,,0.001,0.0009,171.285,0.0592,0.012,0.0096,2881.638,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-07",8,4.96,144.8,,0,0.0008,88.672,0.0599,0.01,0.0155,1490.338,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-08",7,4.04,101.16,,0,0.0009,63.752,0.0594,0.007,0.0256,1072.548,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-09",6,3.28,79.44,,0,0.0007,50.144,0.0593,0.008,0.0215,842.956,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-10",4,2.28,55.96,,0,0.0008,35.006,0.0595,0.006,0.0213,588.894,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-11",6,3.34,85.24,,0,0.0005,53.502,0.0593,0.015,0.0332,899.36,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-12",4,2.68,69.84,,0,0.0008,44.158,0.059,0.007,0.0278,743.869,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-14",4,2.21,54.12,,0,0.0008,34.306,0.0595,0.005,0.0168,576.466,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-15",3,1.13,26.31,,0,0.001,16.795,0.059,0.005,0.021,283.426,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-16",5,3.12,80.14,,0,0.0008,49.536,0.0596,0.006,0.0136,832.19,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-17",5,3.83,112.3,,0,0.001,67.592,0.0596,0.009,0.0172,1136.228,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-23",5,3.67,98.54,,0,0.0006,60.062,0.059,0.008,0.0194,1012.131,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-25",5,3.94,117.86,,0,0.0008,70.366,0.0594,0.009,0.013,1183.62,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-28",7,6.03,177.19,,0.001,0.001,107.8,0.0596,0.011,0.0129,1811.623,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-09-30",7,6.19,170.16,,0.001,0.001,105.485,0.0597,0.011,0.02,1772.637,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-01",11,7.66,224.75,,0.001,0.0008,137.129,0.0595,0.012,0.0172,2306.04,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-02",5,3.67,94.35,,0,0.001,59.313,0.0592,0.007,0.02,998.719,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-03",7,3.84,108.27,,0,0.001,66.53,0.0593,0.011,0.0196,1120.359,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-04",3,1.92,61.72,,0,0.001,36.782,0.0597,0.007,0.0223,618.494,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-05",7,5.67,195.76,,0.001,0.001,113.571,0.0591,0.011,0.0159,1910.583,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-06",6,5,144,,0,0.001,87.236,0.0593,0.01,0.0158,1469.4,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-07",4,2.53,64.33,,0,0.001,39.391,0.0593,0.006,0.0253,662.359,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-10",2,1.2,32.15,,0,0.0005,19.405,0.0595,0.009,0.046,326.335,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-16",2,1.43,38.72,,0,0.001,23.837,0.059,0.006,0.034,401.885,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-17",2,1.2,28.8,,0,0.0005,18.12,0.059,0.008,0.05,305.28,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-18",4,2.37,60.29,,0,0.0008,36.518,0.0593,0.007,0.0228,614.354,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-21",5,3.17,81.01,,0,0.001,49.427,0.0596,0.007,0.0194,831.951,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-22",4,2.68,72.68,,0,0.001,43.824,0.0593,0.01,0.035,737.392,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-23",3,2.53,63.51,,0,0.0007,38.913,0.0597,0.008,0.0233,654.385,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-24",1,0.08,1.36,,0,0,0.968,0.06,0,0.022,16.264,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-25",21,18.28,476.08,,0.002,0.001,292.872,0.0592,0.021,0.011,4930.52,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-26",3,1.16,27.36,,0,0.001,17.152,0.0597,0.004,0.0267,287.844,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-27",3,1.18,27.98,,0,0.0007,17.522,0.06,0.004,0.028,293.978,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-28",3,1.18,28.08,,0,0.0007,17.464,0.059,0.004,0.026,294.42,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-29",5,3.45,97.16,,0,0.001,57.722,0.0592,0.006,0.025,972.489,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-01",4,2.88,85.92,,0,0.001,51.512,0.0593,0.007,0.0148,866.455,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-02",6,4.6,117.56,,0,0.001,71.876,0.0593,0.007,0.0175,1207.852,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-03",4,2.9,72.91,,0,0.0008,44.934,0.0593,0.007,0.0245,756.135,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-04",7,5.83,197.58,,0.001,0.001,114.699,0.0594,0.01,0.0116,1928.519,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-05",8,6.88,184.96,,0.001,0.001,112.988,0.0595,0.012,0.0138,1900.306,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-06",6,4.45,112.1,,0,0.0007,68.15,0.0593,0.008,0.0177,1147.66,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-07",5,3.2,80,,0,0.0008,48.7,0.0594,0.005,0.017,819.03,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-08",2,1.24,27.9,,0,0.0005,17.732,0.0595,0.004,0.0265,298.344,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-09",9,6.23,187.14,,0.001,0.001,109.937,0.0591,0.012,0.02,1851.469,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-10",10,6.61,163.91,,0.001,0.0008,100.303,0.0598,0.01,0.0182,1686.332,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-11",4,2.88,74.18,,0,0.0008,44.986,0.0595,0.007,0.0288,756.04,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-12",3,1.88,45.36,,0,0.0007,27.964,0.0593,0.008,0.0413,470.831,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-13",7,5.63,139.19,,0,0.0006,85.164,0.0591,0.014,0.0264,1432.562,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-14",3,1.69,40.73,,0,0.001,25.132,0.0597,0.005,0.0277,423.304,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-15",7,4.8,138.77,,0,0.0009,82.769,0.0591,0.009,0.0209,1394.222,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-16",9,5.36,131.58,,0.001,0.0008,81.576,0.0593,0.008,0.0177,1371.998,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-17",9,6.42,164.04,,0.001,0.0009,100.482,0.0594,0.013,0.0193,1690.205,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-18",7,5.22,131.84,,0.001,0.001,80.866,0.0591,0.008,0.015,1361.694,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-19",3,1.7,40.74,,0,0.001,25.304,0.059,0.008,0.0413,425.526,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-20",4,3.25,85.2,,0,0.0008,51.78,0.059,0.007,0.0255,872.465,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-24",8,6.15,163.65,,0.001,0.0009,99.95,0.0596,0.012,0.0179,1679.689,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-25",4,3.43,91.18,,0,0.001,55.449,0.059,0.007,0.0183,933.061,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-11-30",7,5.47,172.98,,0.001,0.001,102.232,0.0591,0.017,0.0244,1720.753,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-01",5,3.65,110.33,,0,0.0008,65.744,0.0596,0.012,0.0238,1105.621,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-02",10,7.72,222.9,,0.001,0.0007,133.86,0.0591,0.014,0.0181,2254.352,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-03",6,3.09,88.47,,0,0.001,53.272,0.0597,0.008,0.0227,895.597,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-04",16,13.11,432.14,,0.001,0.0009,251.393,0.0593,0.018,0.0131,4230.969,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-05",7,5.7,156.7,,0.001,0.001,94.7,0.0593,0.011,0.0189,1592.61,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-06",7,5.73,149.27,,0.001,0.0007,90.947,0.0591,0.009,0.021,1531.702,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-07",10,7.77,219.72,,0.001,0.0009,133.018,0.0593,0.02,0.0238,2238.536,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-08",3,2.38,58.87,,0,0.0007,36.881,0.0593,0.006,0.023,620.22,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-09",12,8.78,229.58,,0.001,0.0009,139.486,0.0593,0.018,0.0173,2346.52,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-10",13,9.84,279.5,,0.001,0.0008,167.602,0.0596,0.012,0.0125,2817.058,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-11",14,11.13,338.93,,0.001,0.0009,199.866,0.0591,0.016,0.0132,3365.194,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-12",8,7.2,291.55,,0.001,0.001,163.335,0.0595,0.013,0.0165,2747.39,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-14",12,8.9,232.98,,0.001,0.0008,141.286,0.0592,0.013,0.0161,2379.211,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-15",13,10.38,332.58,,0.001,0.0007,194.894,0.0595,0.013,0.0119,3277.434,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-17",3,1.18,26.3,,0,0.001,17.06,0.059,0.003,0.019,286.86,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-18",6,3.53,102.56,,0,0.0007,61.154,0.0593,0.01,0.019,1029.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-21",4,2.78,68.2,,0,0.001,42.156,0.0593,0.006,0.023,709.436,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-22",4,2.72,71.84,,0,0.001,43.472,0.0593,0.008,0.03,731.892,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-23",5,2.78,64.73,,0,0.0008,40.812,0.0594,0.007,0.0248,687.385,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-24",3,1.22,28.38,,0,0.0007,17.778,0.059,0.004,0.027,299.048,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-29",2,1.26,29.46,,0,0.0005,18.462,0.059,0.007,0.0455,310.598,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-30",2,1.02,23.2,,0,0.001,14.544,0.059,0.006,0.0355,245.042,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-3",,"2020-12-31",5,3.93,109.14,,0,0.0008,66.224,0.0598,0.015,0.0308,1112.338,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-02",5,3.35,88.28,,0,0.001,55.276,0.0592,0.011,0.0304,929.527,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-13",2,1.25,29.53,,0,0.001,19.343,0.0595,0.006,0.041,325.221,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-15",3,1.5,35.28,,0,0.001,22.762,0.0593,0.005,0.0313,382.314,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-16",2,1.22,29.64,,0,0.001,18.72,0.059,0.008,0.043,315.366,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-17",2,1.28,38.85,,0,0.001,23.642,0.06,0.008,0.0495,397.171,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-22",3,2.17,51.85,,0,0.0007,33.379,0.0593,0.006,0.0237,561.112,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-29",6,3.65,87.42,,0,0.0008,56.044,0.0593,0.011,0.035,942.254,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-30",3,1.68,39.17,,0,0.001,25.488,0.0593,0.007,0.0423,428.127,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-02",2,1.17,26.85,,0,0.0005,17.262,0.0595,0.005,0.0345,290.106,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-04",3,1.68,40.22,,0,0.0007,26.102,0.0593,0.006,0.039,438.608,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-10",3,1.68,45.06,,0,0.001,28.048,0.0593,0.006,0.041,472.516,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-12",10,9.34,434.32,,0.001,0.0008,243.642,0.0591,0.023,0.013,4102.008,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-13",8,7.43,268.52,,0.001,0.001,157.096,0.0591,0.014,0.0136,2643.706,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-14",5,3.15,87.75,,0,0.001,54.296,0.0592,0.013,0.0274,913.91,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-21",2,1.19,27.19,,0,0.0005,17.65,0.0595,0.008,0.045,296.516,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-24",4,2.47,69.4,,0,0.001,42.85,0.0595,0.007,0.0323,722.08,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-25",5,3.68,94.28,,0,0.0006,59.759,0.059,0.008,0.0222,1006.443,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-27",3,1.7,38.88,,0,0.001,25.394,0.0597,0.009,0.044,426.428,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-01",3,2.2,55,,0,0.0007,35.08,0.0593,0.012,0.0453,590.16,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-03",3,1.43,35.01,,0,0.0003,22.058,0.0593,0.005,0.0243,371.306,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-10",3,1.69,38.88,,0,0.0007,25.391,0.0597,0.009,0.042,426.359,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-11",2,1.32,52.2,,0,0.001,29.832,0.0595,0.011,0.0475,501.564,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-12",4,1.73,57.56,,0,0.0008,33.986,0.059,0.011,0.0295,571.948,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-13",9,6.88,217.91,,0.001,0.0008,130.375,0.0591,0.023,0.0271,2193.562,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-14",9,6.67,225.45,,0.001,0.0008,132.352,0.0593,0.017,0.0191,2225.855,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-15",3,1.93,53.14,,0,0.0003,32.471,0.059,0.007,0.0243,547.742,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-16",4,2.31,58.38,,0,0.0008,36.815,0.0595,0.013,0.0423,618.754,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-17",2,1.18,27.05,,0,0.0005,17.476,0.0595,0.006,0.0355,294.465,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-29",1,0.43,8.6,,0,0,5.848,0.059,0.003,0.064,98.685,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-04",2,1.13,29.78,,0,0.001,18.753,0.06,0.006,0.0315,314.715,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-06",4,2.22,52.38,,0,0.0008,34.09,0.0593,0.004,0.0238,573.316,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-07",6,3.83,91.9,,0,0.0008,59.264,0.0592,0.015,0.0338,997.485,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-08",3,1.7,40.1,,0,0.001,26.04,0.059,0.005,0.0263,438.39,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-14",4,2.95,73,,0,0.0008,46.38,0.0593,0.007,0.027,781.145,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-16",2,1.72,55.95,,0,0.001,33.307,0.06,0.006,0.0225,559.592,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-17",2,1.7,40.8,,0,0.001,26.265,0.0595,0.009,0.038,441.32,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-20",3,1.2,28.1,,0,0.0007,18.4,0.0597,0.005,0.031,309.25,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-23",4,2.68,66.34,,0,0.0008,42.749,0.0593,0.006,0.0285,719.886,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-24",3,1.95,47.51,,0,0.0007,30.671,0.059,0.005,0.0243,517.012,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-27",6,4.22,106.16,,0,0.0008,68.244,0.0595,0.006,0.0165,1147.212,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-28",4,2.45,60.5,,0,0.001,38.975,0.0593,0.006,0.0298,656.185,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-29",4,2.2,53.9,,0,0.0008,34.87,0.0598,0.006,0.0233,585.76,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-04-30",13,9.52,257.78,,0.001,0.0009,163.124,0.0594,0.015,0.0167,2744.212,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-05",4,2.7,68.8,,0,0.0008,43.69,0.059,0.006,0.0265,735.41,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-06",4,2.35,57.1,,0,0.001,36.66,0.0595,0.004,0.0245,617.905,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-07",5,3.45,89.35,,0,0.0006,56.65,0.0592,0.006,0.018,954.855,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-08",7,4.99,126.91,,0,0.0007,80.233,0.0594,0.011,0.0203,1349.943,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-11",2,1.41,49.6,,0,0.001,29.138,0.059,0.008,0.0345,490.701,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-15",2,1.45,33.85,,0,0.0005,21.94,0.0595,0.008,0.0405,368.905,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-16",5,3.7,89.5,,0,0.001,57.38,0.0592,0.009,0.0258,967.37,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-19",9,7.2,190.7,,0.001,0.001,119.29,0.0596,0.007,0.0106,2006.36,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-26",11,9.62,319.37,,0.001,0.0009,193.281,0.0592,0.016,0.0115,3251.355,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-27",2,1.05,35.28,,0,0.001,21.518,0.0595,0.005,0.0245,361.557,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-28",5,2.26,46.12,,0,0.001,32.131,0.0596,0.007,0.0298,541.152,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-29",2,1.05,21.58,,0,0,14.932,0.059,0.006,0.0455,251.766,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-01",15,11.4,285.4,,0.001,0.001,182.918,0.0595,0.013,0.0153,3077.31,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-02",6,2.91,63.91,,0,0.0008,42.595,0.0595,0.008,0.0267,716.003,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-03",12,8.61,235.54,,0.001,0.0009,146.858,0.0592,0.011,0.0162,2472.655,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-04",6,5.2,134.4,,0,0.0007,85.02,0.0593,0.011,0.0217,1430.72,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-05",4,2.23,51.13,,0,0.001,33.132,0.0595,0.004,0.0205,557.772,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-08",5,4.15,104.31,,0,0.0006,66.263,0.0598,0.01,0.0236,1112.872,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-09",5,4.51,124.43,,0,0.001,77.783,0.0594,0.009,0.0158,1308.998,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-10",9,6.97,221.44,,0.001,0.0007,134.146,0.0593,0.015,0.019,2257.098,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-11",5,3.7,104.7,,0,0.001,65.35,0.0594,0.007,0.0166,1099.28,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-17",4,2.15,51.15,,0,0.001,32.805,0.0595,0.004,0.0188,551.914,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-18",5,3.25,79.15,,0,0.001,51.436,0.0594,0.004,0.0192,865.953,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-22",6,3.33,82.38,,0,0.001,53.295,0.0595,0.004,0.0198,896.666,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-23",5,3.3,86.22,,0,0.001,55.434,0.059,0.004,0.0202,934.115,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-24",5,3.5,88.81,,0,0.0008,57.139,0.0592,0.005,0.021,962.282,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-25",5,3.3,82.86,,0,0.001,53.262,0.0594,0.004,0.0196,896.474,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-26",10,7.68,204.55,,0.001,0.001,129.099,0.0592,0.017,0.0176,2172.821,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-27",3,2.72,107.73,,0,0.001,62.012,0.059,0.009,0.0183,1044.146,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-29",3,2,47.24,,0,0.001,30.532,0.059,0.006,0.0253,515.216,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-06-30",3,2.55,96.6,,0,0.001,56.33,0.059,0.01,0.022,948.395,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-01",3,2.48,94.39,,0,0.0007,54.694,0.0593,0.007,0.0183,920.669,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-02",3,1.7,53.3,,0,0.001,32.4,0.0593,0.005,0.0203,545.57,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-03",3,1.61,47.22,,0,0.001,29.112,0.059,0.009,0.039,490.522,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-04",2,0.79,19.09,,0,0.0005,12.218,0.06,0.002,0.0255,205.279,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-05",8,5.81,134.84,,0,0.0008,89.078,0.0593,0.018,0.0295,1499.744,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-09",10,9.33,307.8,,0.001,0.0008,184.867,0.0593,0.014,0.0113,3110.694,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-10",7,5.64,211.28,,0.001,0.0007,123.12,0.0593,0.017,0.0184,2071.02,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-11",10,8.03,229.98,,0.001,0.001,142.153,0.0595,0.018,0.0262,2389.144,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-12",5,4.46,163.45,,0,0.001,95.646,0.0592,0.01,0.0158,1609.568,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-15",6,2.73,60.45,,0,0.0005,40.016,0.0592,0.015,0.0487,673.132,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-16",2,1.08,25.08,,0,0.001,16.332,0.059,0.001,0.016,275.412,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-20",7,5.11,139.2,,0.001,0.001,86.37,0.0593,0.009,0.0133,1453.541,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-21",5,3.14,81.26,,0,0.0008,51.326,0.0594,0.006,0.0132,862.684,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-23",12,10.24,285.44,,0.001,0.001,175.934,0.0592,0.013,0.0109,2960.782,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-26",15,11.38,298.52,,0.001,0.0009,188.802,0.0594,0.015,0.0142,3175.414,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-27",5,3.45,88.8,,0,0.0008,56.18,0.0592,0.007,0.0222,946.35,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-28",10,8.2,232.24,,0.001,0.0009,143.964,0.0592,0.011,0.0121,2423.636,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-29",7,5.43,160.83,,0.001,0.0009,98.583,0.0591,0.008,0.0169,1660.556,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-30",6,4.7,160.2,,0.001,0.0007,95.64,0.0592,0.009,0.0147,1610.94,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-07-31",5,3.43,85.84,,0,0.0006,54.44,0.0594,0.006,0.0184,916.906,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-01",5,3.47,86.11,,0,0.0006,54.94,0.0592,0.007,0.0206,925.206,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-02",1,0.97,24.25,,0,0.001,15.423,0.059,0.005,0.036,259.281,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-03",8,4.48,114.03,,0,0.0008,72.752,0.0595,0.011,0.0253,1223.905,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-04",14,12.23,314.45,,0.001,0.0009,198.832,0.0593,0.012,0.0099,3345.244,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-05",5,3.19,78.53,,0,0.0008,49.935,0.0594,0.006,0.0132,839.853,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-06",3,1.22,28.14,,0,0.0007,18.096,0.0593,0.004,0.0263,304.422,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-07",12,10.27,282.29,,0.001,0.001,175.776,0.0593,0.012,0.0128,2957.033,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-10",5,3.21,80.86,,0,0.001,51.315,0.0594,0.005,0.0204,862.634,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-12",5,3.93,99.12,,0,0.0008,63.594,0.0594,0.012,0.0308,1070.198,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-13",8,7.73,264.4,,0.001,0.001,157.189,0.0593,0.015,0.0133,2644.632,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-14",13,11,419.9,,0.001,0.0009,243.296,0.0592,0.02,0.0125,4093.085,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-15",13,12.85,451.63,,0.001,0.0009,267.67,0.0593,0.024,0.0111,4504.182,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-16",14,11.72,367.86,,0.001,0.0009,223.734,0.0592,0.015,0.0126,3766.316,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-17",17,16.2,534.3,,0.002,0.0009,322.855,0.0591,0.022,0.0086,5437.435,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-18",19,17.54,486.9,,0.002,0.001,307.096,0.0591,0.023,0.011,5172.054,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-19",21,17.39,434.41,,0.002,0.001,280.894,0.0594,0.021,0.0117,4726.054,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-20",12,8.29,213.16,,0.001,0.0009,136.007,0.0592,0.014,0.0158,2288.52,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-21",13,9.96,248.24,,0.001,0.0009,159.676,0.0592,0.013,0.0141,2688.442,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-22",7,6.05,161.75,,0.001,0.001,102.69,0.0594,0.011,0.0141,1726.845,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-23",7,3.38,72.23,,0,0.0007,49.165,0.0593,0.008,0.0239,825.639,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-24",8,6.2,165,,0.001,0.0009,104.95,0.0593,0.009,0.0148,1764.18,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-25",6,4.2,110.1,,0,0.0008,69.75,0.0593,0.008,0.0182,1172.16,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-26",7,5.38,141.4,,0.001,0.001,88.787,0.059,0.007,0.0181,1496.035,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-27",7,4.58,118.85,,0,0.0007,75.378,0.0591,0.007,0.0209,1268.051,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-28",13,10.43,275.57,,0.001,0.0009,174.216,0.0594,0.011,0.0112,2931.577,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-29",5,3.69,92.5,,0,0.001,60.094,0.059,0.009,0.023,1011.441,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-03",16,12.61,325.33,,0.001,0.0009,207.917,0.0594,0.014,0.0124,3498.055,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-04",6,4.2,105.9,,0,0.0008,67.71,0.0593,0.004,0.0147,1138.77,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-05",16,12.85,346.75,,0.001,0.0009,219.363,0.0593,0.017,0.0128,3693.112,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-06",10,8.17,233.75,,0.001,0.001,146.178,0.0595,0.013,0.012,2457.305,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-07",8,4.94,132.02,,0,0.0009,84.614,0.0595,0.01,0.0195,1423.29,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-08",7,4.04,94.7,,0,0.0009,62.81,0.0594,0.007,0.0263,1056.714,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-09",5,2.16,48.16,,0,0.0006,32.088,0.0596,0.008,0.0274,538.62,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-10",4,2.28,53.96,,0,0.0008,35.334,0.0595,0.005,0.0205,593.568,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-11",6,3.34,81.76,,0,0.0005,52.872,0.0592,0.013,0.0312,890.8,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-12",4,2.73,65.94,,0,0.0005,43.069,0.0595,0.007,0.0315,724.696,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-14",4,2.28,54.02,,0,0.001,35.061,0.0595,0.003,0.021,590.516,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-15",3,1.13,26.31,,0,0.001,17.202,0.059,0.005,0.0233,290.301,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-16",5,3.12,80.14,,0,0.001,50.774,0.0592,0.005,0.0116,855.23,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-17",5,3.83,100.08,,0,0.001,63.578,0.0594,0.007,0.016,1069.818,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-22",4,2.45,61.61,,0,0.001,39.971,0.0595,0.006,0.0303,672.532,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-23",5,3.67,95.44,,0,0.0008,60.923,0.0594,0.008,0.019,1025.524,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-25",5,4.15,122.41,,0,0.001,75.333,0.0594,0.009,0.0244,1267.356,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-29",4,2.7,75.05,,0,0.0008,47.02,0.0595,0.006,0.0283,790.795,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-09-30",11,9.22,258.94,,0.001,0.0009,163.468,0.0595,0.012,0.0126,2748.958,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-01",11,7.66,219.17,,0.001,0.0008,137.816,0.0593,0.012,0.0182,2318.146,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-02",8,4.84,119.29,,0,0.001,78.464,0.0593,0.01,0.021,1320.411,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-03",4,2.67,76.92,,0,0.001,48.142,0.0598,0.006,0.0218,808.621,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-04",3,1.9,61.7,,0,0.001,37.2,0.059,0.006,0.023,626.462,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-05",7,5.65,189.17,,0.001,0.0009,113.095,0.0593,0.011,0.0159,1902.674,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-06",6,5,143,,0,0.001,88.436,0.0592,0.009,0.0155,1487.332,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-07",6,4.18,110.98,,0,0.0008,68.972,0.0593,0.006,0.016,1160.342,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-10",2,1.2,31.3,,0,0.0005,19.715,0.0595,0.009,0.047,331.28,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-16",2,1.43,38.17,,0,0.001,24.101,0.0595,0.007,0.039,404.965,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-17",2,1.2,28.8,,0,0.0005,18.3,0.0595,0.009,0.0595,307.62,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-22",3,1.45,33.96,,0,0.001,22.156,0.059,0.005,0.0373,372.743,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-23",4,2.94,74.48,,0,0.0005,46.956,0.0595,0.007,0.028,790.469,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-28",3,1.58,45.1,,0,0.0007,27.946,0.059,0.005,0.0247,471.264,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-29",8,4.67,123.41,,0,0.0008,76.764,0.0596,0.011,0.0263,1291.445,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-30",7,3.59,90.49,,0,0.0007,57.803,0.0594,0.011,0.0219,971.568,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-10-31",9,5.36,136.93,,0.001,0.0008,87.269,0.0591,0.014,0.0222,1469.055,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-01",14,11.51,296.08,,0.001,0.001,188.075,0.0591,0.011,0.0091,3165.658,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-02",8,6.18,154.68,,0.001,0.0009,98.85,0.059,0.008,0.0139,1664.764,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-03",7,5.47,150.36,,0.001,0.0007,94.119,0.0591,0.009,0.0169,1584.277,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-04",9,7.43,204.48,,0.001,0.001,127.865,0.0593,0.01,0.0161,2150.38,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-05",13,9.4,245.84,,0.001,0.0008,155.288,0.0593,0.011,0.0145,2614.554,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-06",6,4.45,110.45,,0,0.0007,69.655,0.0595,0.007,0.0165,1171.285,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-07",5,3.22,80.04,,0,0.0008,50.564,0.0598,0.005,0.0172,849.938,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-08",5,2.87,67.78,,0,0.0008,43.034,0.0598,0.01,0.0298,723.842,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-09",9,6.23,170.79,,0.001,0.0009,106.328,0.0592,0.014,0.0242,1789.11,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-10",7,5.16,131.2,,0.001,0.001,82.752,0.0593,0.008,0.0156,1391.516,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-11",4,2.88,72.18,,0,0.0008,45.732,0.0598,0.006,0.0278,768.59,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-12",3,1.88,43.81,,0,0.0007,28.495,0.059,0.008,0.0417,479.701,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-13",7,5.65,136.7,,0,0.0007,87.715,0.0593,0.016,0.0303,1475.365,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-14",3,1.69,40.04,,0,0.001,25.558,0.059,0.005,0.0273,430.382,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-15",7,5.43,162.12,,0.001,0.001,97.896,0.0591,0.009,0.0191,1647.752,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-16",9,5.38,128.48,,0.001,0.0009,82.82,0.0593,0.009,0.0198,1395.13,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-17",9,6.42,159.04,,0.001,0.0009,101.906,0.0591,0.013,0.0206,1715.178,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-18",7,5.22,126.84,,0.001,0.0009,82.32,0.0593,0.008,0.0159,1384.218,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-19",3,1.18,27.78,,0,0.0007,17.86,0.0597,0.004,0.03,299.77,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-01",5,3.67,107.13,,0,0.0008,65.72,0.059,0.013,0.026,1107.517,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-02",10,7.72,220.4,,0.001,0.0008,136.109,0.0593,0.014,0.0177,2288.401,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-03",7,4.25,120.64,,0,0.0009,74.538,0.0593,0.01,0.0289,1254.7,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-04",16,13.33,441.84,,0.001,0.0009,263.297,0.059,0.026,0.0158,4433.569,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-05",7,5.7,155.1,,0.001,0.001,96.81,0.0594,0.011,0.0189,1628.45,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-06",7,5.73,143.89,,0.001,0.0009,92.436,0.0591,0.01,0.0216,1555.541,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-07",9,6.95,205.33,,0.001,0.0009,125.845,0.0596,0.014,0.0199,2115.963,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-08",3,2.38,55.97,,0,0.0007,36.777,0.059,0.006,0.0227,619.589,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-09",14,10.28,263.86,,0.001,0.0009,166.32,0.0597,0.016,0.0143,2795.614,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-10",11,8.36,230.6,,0.001,0.0009,142.97,0.0595,0.015,0.0167,2403.754,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-11",12,9.78,297.78,,0.001,0.0009,181.51,0.0593,0.018,0.0152,3054.665,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-12",8,7.2,281.7,,0.001,0.001,163.095,0.0591,0.015,0.0189,2745.39,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-14",10,7.4,183.7,,0.001,0.0008,117.635,0.0596,0.014,0.0202,1978.059,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-15",11,9.28,296.68,,0.001,0.0007,178.298,0.0594,0.016,0.0139,2998.118,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-16",9,8.06,287.25,,0.001,0.001,169.386,0.0592,0.018,0.0136,2851.459,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-17",5,2.36,55.16,,0,0.0006,35.83,0.0594,0.007,0.024,602.768,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-18",7,5.45,165,,0.001,0.0007,100.59,0.059,0.009,0.0153,1694.87,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-21",7,3.96,94.98,,0,0.0009,60.612,0.0594,0.009,0.0216,1020.006,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-23",6,4.28,102.14,,0,0.0008,65.924,0.0592,0.01,0.0215,1109.888,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-24",3,1.22,27.38,,0,0.0007,18.244,0.0593,0.004,0.0303,306.598,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-29",5,2.48,59.14,,0,0.0006,38.09,0.0592,0.008,0.0286,640.794,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Mariposa Energy Project",57483,"GT-4",,"2020-12-31",5,3.93,107.14,,0,0.0008,67.19,0.0592,0.015,0.031,1130.712,"Pipeline Natural Gas",,"Combustion turbine",,"Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-06",16,13.96,1075.4,,0.003,0.001,568.438,0.0591,0.045,0.0139,9564.745,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-15",4,2.96,236.07,,0.001,0.001,122.312,0.0593,0.013,0.0158,2057.202,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-17",3,1.46,104.12,,0,0.001,54.4,0.059,0.01,0.045,915.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-26",11,9.21,536.11,,0.002,0.001,302.424,0.059,0.025,0.0196,5090.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-27",4,2.46,171.82,,0,0.001,91.648,0.059,0.011,0.0363,1541.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-28",4,2.21,137.39,,0,0.001,76.042,0.059,0.01,0.0388,1280.015,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-29",5,4.21,353.97,,0.001,0.001,182.041,0.0592,0.018,0.013,3062.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-01-31",4,2.96,222.73,,0.001,0.001,117.029,0.059,0.012,0.0138,1969.723,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-03",10,6.94,471.25,,0.001,0.001,255.873,0.0592,0.029,0.0256,4305.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-04",7,5.44,406.86,,0.001,0.001,214.988,0.0593,0.023,0.0154,3616.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-05",9,6.19,542,,0.001,0.001,274.719,0.0592,0.034,0.0311,4623.603,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-06",7,5.21,502.87,,0.001,0.001,254.333,0.0593,0.023,0.0266,4280.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-07",6,4.98,406.68,,0.001,0.001,210.619,0.059,0.023,0.0152,3545.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-08",8,4.63,397.34,,0.001,0.001,201.028,0.0593,0.019,0.0513,3382.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-09",6,4.96,419.07,,0.001,0.001,214.582,0.059,0.018,0.0117,3608.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-16",5,3.11,237.81,,0.001,0.001,123.113,0.059,0.016,0.0214,2070.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-17",5,4.23,354.43,,0.001,0.001,181.918,0.059,0.016,0.0122,3061.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-19",8,7.83,598.16,,0.002,0.001,314.017,0.059,0.024,0.0103,5279.739,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-20",10,8.98,591.83,,0.002,0.001,323.168,0.059,0.025,0.01,5438.863,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-21",2,1.13,54.78,,0,0.001,32.852,0.0595,0.002,0.007,552.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-24",5,4.21,331.44,,0.001,0.001,172.236,0.059,0.016,0.012,2899.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-25",8,7.58,562.34,,0.001,0.001,296.456,0.0591,0.024,0.0114,4989.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-26",10,8.98,776.7,,0.002,0.001,397.529,0.0591,0.028,0.0096,6690.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-27",6,4.11,311.31,,0.001,0.001,164.232,0.0593,0.015,0.0115,2763.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-28",6,4.21,354.82,,0.001,0.001,184.189,0.059,0.019,0.0295,3099.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-02-29",9,8.1,456.2,,0.001,0.001,259.59,0.0592,0.021,0.0192,4368.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-01",8,6.34,466.32,,0.001,0.001,245.75,0.059,0.019,0.01,4135.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-02",5,3.46,293.58,,0.001,0.001,149.86,0.059,0.019,0.0374,2522.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-03",5,4.48,321.82,,0.001,0.001,171.096,0.059,0.016,0.0124,2877.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-04",6,4.23,330.44,,0.001,0.001,172.28,0.0592,0.015,0.0288,2899.489,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-05",4,3.48,259.86,,0.001,0.001,136.419,0.059,0.013,0.0133,2295.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-06",4,2.96,222.73,,0.001,0.001,117.46,0.0593,0.012,0.012,1975.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-08",7,5.98,436.96,,0.001,0.001,232.458,0.059,0.019,0.0111,3912.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-09",9,6.71,601.88,,0.002,0.001,305.725,0.059,0.032,0.0227,5144.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-10",11,8.96,756.67,,0.002,0.001,389.558,0.0591,0.032,0.0175,6553.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-11",6,4.98,321.26,,0.001,0.001,177.496,0.0597,0.017,0.0122,2984.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-12",12,8.71,782.35,,0.002,0.001,395.629,0.0592,0.038,0.0265,6657.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-13",12,9.69,804.91,,0.002,0.001,418.552,0.0591,0.036,0.0253,7043.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-14",19,18.65,1238.95,,0.003,0.001,686.355,0.059,0.049,0.0091,11546.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-15",8,6.34,539.22,,0.001,0.001,277.043,0.059,0.023,0.0108,4663.347,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-16",11,7.92,700.88,,0.002,0.001,357.362,0.059,0.036,0.0278,6010.279,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-17",10,6.42,531.42,,0.001,0.001,272.081,0.059,0.031,0.0309,4579.034,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-18",7,3.67,310.64,,0.001,0.001,157.429,0.0591,0.024,0.041,2650.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-19",6,4.21,348.9,,0.001,0.001,180.419,0.0592,0.018,0.0255,3037.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-20",5,3.21,243.42,,0.001,0.001,129.245,0.0592,0.014,0.0294,2174.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-24",5,3.21,250.95,,0.001,0.001,131.802,0.0592,0.015,0.0306,2216.897,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-27",2,1.48,76.31,,0,0.001,43.815,0.0595,0.009,0.0215,737.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-28",5,3.71,296.55,,0.001,0.001,154.674,0.059,0.016,0.0298,2602.771,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-30",7,3.94,251.92,,0.001,0.001,136.231,0.0591,0.019,0.0337,2293.066,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-03-31",3,1.46,116.51,,0,0.001,59.298,0.059,0.013,0.0363,997.531,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-01",6,4.46,349.78,,0.001,0.001,183.284,0.0592,0.015,0.0252,3082.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-02",3,1.71,117.08,,0,0.001,62.691,0.0593,0.009,0.0457,1053.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-03",3,2.46,234.08,,0.001,0.001,115.658,0.059,0.016,0.02,1946.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-04",5,3.73,338.39,,0.001,0.001,171.064,0.0592,0.018,0.0306,2877.799,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-05",15,13.46,1218.51,,0.003,0.001,617.043,0.059,0.047,0.0119,10381.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-06",8,5.19,434.38,,0.001,0.001,220.917,0.0591,0.025,0.0341,3718.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-07",8,5.21,358.04,,0.001,0.001,191.264,0.0593,0.026,0.0351,3218.233,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-08",5,3.21,262.61,,0.001,0.001,134.9,0.0592,0.015,0.0312,2270.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-09",12,9.71,833.38,,0.002,0.001,425.639,0.0591,0.039,0.0122,7162.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-12",4,2.96,208.07,,0.001,0.001,109.62,0.059,0.012,0.0133,1846.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-13",5,4,290.7,,0.001,0.001,154.555,0.0592,0.015,0.012,2599.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-14",9,6.91,524.02,,0.001,0.001,274.754,0.059,0.03,0.0136,4621.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-15",4,2.98,224.26,,0.001,0.001,119.378,0.059,0.012,0.014,2008.858,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-16",4,3.48,275.9,,0.001,0.001,143.513,0.059,0.014,0.013,2414.617,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-17",3,1.46,78,,0,0.001,44.468,0.0593,0.008,0.0463,748.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-19",5,3.96,317.07,,0.001,0.001,163.921,0.0594,0.015,0.0128,2757.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-22",4,2.98,237.34,,0.001,0.001,123.738,0.059,0.013,0.014,2082.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-23",7,6,431.55,,0.001,0.001,232.025,0.0591,0.019,0.0106,3906.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-24",6,5.21,423.69,,0.001,0.001,221.029,0.059,0.023,0.012,3719.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-25",4,2.96,194.24,,0.001,0.001,106.878,0.059,0.011,0.0128,1798.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-26",4,3.73,280.66,,0.001,0.001,149.2,0.059,0.014,0.013,2510.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-27",4,3.46,225.98,,0.001,0.001,124.159,0.059,0.012,0.0123,2089.167,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-28",5,4.23,296.2,,0.001,0.001,159.789,0.059,0.015,0.0118,2687.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-29",5,3.21,249.63,,0.001,0.001,132.616,0.059,0.013,0.0296,2229.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-01",6,4.98,389.96,,0.001,0.001,205.229,0.0593,0.021,0.0117,3452.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-03",7,6.08,462.88,,0.001,0.001,244.484,0.0591,0.021,0.0234,4114.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-04",8,6.98,475.41,,0.001,0.001,259.681,0.059,0.021,0.0106,4369.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-05",9,6.38,557.31,,0.001,0.001,284.396,0.0591,0.024,0.021,4784.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-06",6,4.48,340.54,,0.001,0.001,179.324,0.0592,0.017,0.027,3017.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-07",6,4.48,390.6,,0.001,0.001,199.906,0.059,0.02,0.0278,3363.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-08",3,1.98,137.27,,0,0.001,73.076,0.059,0.011,0.0277,1229.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-09",7,5.48,408.76,,0.001,0.001,215.978,0.059,0.021,0.0237,3634.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-11",7,6.08,410.72,,0.001,0.001,220.712,0.0591,0.022,0.0251,3714.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-12",1,0.15,0.9,,0,0.001,1.545,0.059,0,0.009,26.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-14",4,2.46,214.58,,0.001,0.001,107.954,0.059,0.014,0.038,1815.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-15",4,2.48,210.72,,0.001,0.001,107.602,0.059,0.013,0.0358,1809.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-16",8,7.1,575.7,,0.002,0.001,300.23,0.0593,0.024,0.021,5050.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-17",6,3.36,273.49,,0.001,0.001,140.288,0.059,0.014,0.0268,2360.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-18",4,2.48,160.22,,0,0.001,86.74,0.0593,0.01,0.034,1458.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-21",4,2.46,180.04,,0,0.001,95.634,0.059,0.011,0.0373,1609.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-22",5,3.21,213.24,,0.001,0.001,116.547,0.0592,0.014,0.0302,1961.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-24",5,3.23,287.01,,0.001,0.001,147.037,0.0592,0.016,0.0306,2473.521,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-25",6,4.23,397.71,,0.001,0.001,202.027,0.0592,0.02,0.0277,3400.777,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-26",7,5.23,438.78,,0.001,0.001,229.168,0.0591,0.021,0.0241,3855.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-27",4,3.23,262.87,,0.001,0.001,137.065,0.0593,0.015,0.0125,2307.801,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-28",4,2.21,191.79,,0,0.001,98.283,0.0593,0.013,0.036,1653.982,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-29",6,4.73,393.72,,0.001,0.001,205.142,0.059,0.02,0.0177,3451.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-30",8,6.71,438.76,,0.001,0.001,243.439,0.0591,0.02,0.0216,4095.333,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-05-31",8,7.1,515.1,,0.001,0.001,277.93,0.059,0.023,0.0215,4675.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-01",5,3.34,216.5,,0.001,0.001,118.354,0.059,0.014,0.0122,1992.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-02",7,5.25,453.35,,0.001,0.001,234.095,0.0591,0.021,0.0234,3938.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-03",8,6.23,526.14,,0.001,0.001,274.295,0.0591,0.023,0.0215,4615.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-04",7,6.58,408.16,,0.001,0.001,229.974,0.059,0.018,0.0116,3872.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-05",5,2.36,188.25,,0,0.001,97.66,0.0592,0.018,0.0332,1644.399,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-07",7,6.1,503.3,,0.001,0.001,262.02,0.059,0.029,0.0261,4408.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-08",7,4.34,366.54,,0.001,0.001,189.562,0.0593,0.018,0.0264,3189.282,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-09",4,2.96,274.52,,0.001,0.001,138.036,0.059,0.017,0.0173,2322.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-10",7,6.83,488.02,,0.001,0.001,264.259,0.059,0.024,0.0106,4446.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-11",8,6.48,445.49,,0.001,0.001,244.956,0.0591,0.021,0.0154,4120.003,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-12",4,1.61,125.61,,0,0.001,65.582,0.0593,0.012,0.0373,1103.729,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-13",5,3.21,285.58,,0.001,0.001,145.718,0.059,0.017,0.0326,2452.494,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-14",4,2.48,202.52,,0.001,0.001,105.568,0.059,0.013,0.0355,1777.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-15",12,10.37,884.05,,0.002,0.001,455.557,0.059,0.039,0.0181,7664.164,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-16",5,3.23,252.38,,0.001,0.001,132.872,0.059,0.016,0.031,2236.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-17",6,4.23,337.37,,0.001,0.001,178.672,0.0592,0.018,0.0267,3007.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-18",5,3.23,272.97,,0.001,0.001,141.421,0.0592,0.016,0.0292,2379.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-20",4,2.73,250.4,,0.001,0.001,127.034,0.0593,0.015,0.0353,2135.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-21",4,2.73,233.03,,0.001,0.001,120.256,0.059,0.014,0.0343,2023.627,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-22",10,6.71,536.03,,0.001,0.001,279.71,0.0591,0.027,0.0294,4707.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-23",7,6.85,520.95,,0.001,0.001,277.495,0.0591,0.024,0.0104,4668.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-24",6,3.61,273.56,,0.001,0.001,145.047,0.059,0.016,0.0255,2440.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-25",5,3.48,218.8,,0.001,0.001,122.136,0.059,0.013,0.0288,2055.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-26",7,5.78,469.26,,0.001,0.001,245.192,0.059,0.023,0.0127,4127.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-27",6,4.21,372.79,,0.001,0.001,190.886,0.0592,0.019,0.0263,3211.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-28",4,2.21,175.63,,0,0.001,91.603,0.0595,0.012,0.0365,1540.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-29",4,2.48,213.46,,0.001,0.001,109.382,0.059,0.014,0.036,1840.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-06-30",7,6.35,466.2,,0.001,0.001,250.59,0.0591,0.022,0.0157,4214.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-01",8,6.23,449.01,,0.001,0.001,241.085,0.059,0.021,0.0216,4057.822,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-02",6,3.61,312.89,,0.001,0.001,161.517,0.0592,0.017,0.028,2718.362,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-03",6,4.98,363.58,,0.001,0.001,197.366,0.0592,0.018,0.026,3319.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-04",6,4.21,311.31,,0.001,0.001,168.107,0.0592,0.018,0.0287,2827.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-05",9,7.48,583.46,,0.002,0.001,310.436,0.0591,0.027,0.0214,5223.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-06",7,5.23,461.98,,0.001,0.001,237.965,0.059,0.021,0.0246,4004.597,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-07",7,5.23,434.81,,0.001,0.001,227.147,0.0593,0.021,0.025,3823.097,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-08",5,3.23,276.81,,0.001,0.001,144.403,0.059,0.016,0.0324,2430.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-09",8,6.23,501.51,,0.001,0.001,265.747,0.059,0.022,0.0215,4469.671,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-10",8,6.98,679.86,,0.002,0.001,345.568,0.059,0.031,0.0124,5815.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-11",9,7.23,654.04,,0.002,0.001,335.746,0.059,0.027,0.0194,5650.159,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-12",7,5.96,551.54,,0.001,0.001,282.347,0.059,0.026,0.017,4751.173,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-13",8,5.21,369.83,,0.001,0.001,199.53,0.0591,0.023,0.0271,3356.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-14",4,2.98,241.52,,0.001,0.001,126.73,0.059,0.013,0.0143,2132.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-15",4,2.46,226.8,,0.001,0.001,115.286,0.059,0.015,0.0373,1941.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-16",9,5.69,473.99,,0.001,0.001,247.459,0.059,0.026,0.0319,4164.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-17",9,7.43,521.1,,0.001,0.001,283.921,0.0591,0.022,0.019,4777.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-18",5,3.48,313.7,,0.001,0.001,160.446,0.059,0.017,0.0312,2699.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-19",4,2.23,175.81,,0,0.001,92.011,0.059,0.012,0.0373,1548.497,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-21",6,4.21,361.18,,0.001,0.001,187.065,0.059,0.019,0.0277,3147.783,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-22",2,1.16,89.89,,0,0.001,47.275,0.059,0.011,0.0235,795.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-23",6,4.48,292.92,,0.001,0.001,162.382,0.0592,0.014,0.0255,2732.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-24",4,3.21,269.61,,0.001,0.001,139.96,0.059,0.015,0.0125,2353.823,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-25",6,4.48,390.82,,0.001,0.001,202.208,0.059,0.021,0.0273,3401.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-26",8,7.08,565.32,,0.002,0.001,298.984,0.0591,0.027,0.023,5031.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-27",6,4.11,366.79,,0.001,0.001,189.018,0.059,0.022,0.0148,3181.037,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-28",7,5.23,434.81,,0.001,0.001,227.437,0.059,0.021,0.0236,3827.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-29",8,6.23,565.71,,0.001,0.001,291.504,0.059,0.025,0.0218,4904.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-30",6,5.85,557.45,,0.001,0.001,283.09,0.059,0.025,0.0108,4763.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-07-31",9,8.48,782.08,,0.002,0.001,401.784,0.0591,0.033,0.0111,6759.592,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-03",3,2.21,127.18,,0,0.001,72.885,0.059,0.009,0.0267,1225.771,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-05",4,2.48,224.98,,0.001,0.001,115.42,0.059,0.014,0.034,1942.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-06",4,2.25,192,,0.001,0.001,99.645,0.059,0.013,0.0375,1675.825,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-07",5,3.48,311.08,,0.001,0.001,160.432,0.059,0.018,0.0322,2699.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-08",5,3.5,326.3,,0.001,0.001,166.74,0.0592,0.018,0.0318,2805.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-09",5,3.48,308.98,,0.001,0.001,158.682,0.059,0.016,0.0306,2669.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-10",5,3.23,284.68,,0.001,0.001,146.602,0.059,0.015,0.0308,2468.101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-11",5,3.23,273.74,,0.001,0.001,141.793,0.059,0.016,0.0332,2384.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-12",9,8.08,608.72,,0.002,0.001,327.22,0.059,0.028,0.0218,5506.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-13",8,6.09,454.59,,0.001,0.001,243.423,0.059,0.021,0.0241,4094.683,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-14",10,9.48,826.32,,0.002,0.001,427.3,0.059,0.033,0.0107,7188.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-15",6,4.74,299.2,,0.001,0.001,167.286,0.059,0.018,0.0115,2816.696,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-16",3,1.98,103.24,,0,0.001,60.634,0.0593,0.008,0.0453,1020.652,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-17",13,11.23,865.91,,0.002,0.001,462.491,0.0591,0.035,0.0165,7783.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-18",10,9.26,888.94,,0.002,0.001,453.664,0.059,0.035,0.0095,7634.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-19",9,8.48,768.88,,0.002,0.001,394.355,0.059,0.032,0.0099,6637.267,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-20",10,8.23,696.31,,0.002,0.001,363.008,0.059,0.03,0.0192,6107.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-21",8,6.48,536.44,,0.001,0.001,282.106,0.0591,0.024,0.0215,4744.818,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-22",7,5.71,490.98,,0.001,0.001,256.185,0.059,0.025,0.0241,4311.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-23",7,5.23,463.81,,0.001,0.001,241.658,0.0591,0.021,0.0233,4066.217,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-24",9,7.71,738.47,,0.002,0.001,378.436,0.0591,0.032,0.0208,6365.519,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-25",8,5.9,478.39,,0.001,0.001,252.749,0.059,0.027,0.0293,4253.353,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-26",3,1.98,144.28,,0,0.001,78.042,0.059,0.013,0.0297,1313.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-27",9,7.48,690.68,,0.002,0.001,355.276,0.0591,0.032,0.0213,5976.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-28",6,5.73,449.01,,0.001,0.001,240.053,0.0592,0.02,0.0107,4039.229,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-02",4,2.23,161.21,,0,0.001,87.357,0.059,0.012,0.0383,1469.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-03",6,4.73,409.36,,0.001,0.001,215.616,0.0592,0.021,0.0272,3627.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-04",7,6.48,576.85,,0.002,0.001,301.772,0.059,0.028,0.0113,5077.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-05",12,11.08,901.32,,0.002,0.001,478.192,0.059,0.036,0.0165,8044.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-06",3,0.74,18.03,,0,0.001,13.566,0.0597,0.007,0.0493,228.151,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-10",7,4.25,385.64,,0.001,0.001,197.184,0.0591,0.023,0.0223,3319.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-11",6,4.23,380.81,,0.001,0.001,195.931,0.059,0.019,0.0282,3296.941,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-12",6,4.46,416.4,,0.001,0.001,212.442,0.059,0.021,0.0282,3575.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-13",10,9.58,861.2,,0.002,0.001,443.064,0.059,0.036,0.0111,7454.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-14",7,4.59,411.39,,0.001,0.001,210.992,0.0591,0.021,0.0254,3550.422,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-15",7,5.21,489.5,,0.001,0.001,250.206,0.0591,0.023,0.0239,4210.173,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-16",7,5.21,473.5,,0.001,0.001,242.209,0.0591,0.022,0.0247,4075.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-17",8,6.73,609.82,,0.002,0.001,313.5,0.059,0.029,0.0123,5273.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-18",9,7.46,630.74,,0.002,0.001,328.846,0.059,0.027,0.0211,5532.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-19",9,7.71,720.02,,0.002,0.001,367.856,0.0591,0.032,0.0209,6188.263,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-20",10,8.96,820.07,,0.002,0.001,420.159,0.059,0.033,0.0136,7071.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-21",6,4.48,421.18,,0.001,0.001,214.754,0.0592,0.021,0.0278,3612.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-22",7,4.71,403.23,,0.001,0.001,209.577,0.0593,0.024,0.0266,3526.285,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-23",9,7.73,637.18,,0.002,0.001,333.886,0.0591,0.028,0.0118,5619.995,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-24",5,3.48,315.7,,0.001,0.001,161.718,0.059,0.017,0.0314,2721.484,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-25",14,13.85,1087.35,,0.003,0.001,584.14,0.059,0.046,0.0093,9833.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-26",6,3.59,308.06,,0.001,0.001,160.102,0.0593,0.019,0.0283,2691.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-27",6,4.48,384.34,,0.001,0.001,201.6,0.059,0.021,0.028,3392.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-28",7,5.23,412.78,,0.001,0.001,221.382,0.0591,0.02,0.0237,3725.276,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-29",3,2.21,154.07,,0,0.001,84.801,0.059,0.012,0.015,1428.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-09-30",5,3.48,276.18,,0.001,0.001,147.458,0.059,0.015,0.0316,2480.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-02",7,5.48,356.44,,0.001,0.001,199.166,0.0591,0.026,0.0204,3350.681,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-03",8,5.96,479.98,,0.001,0.001,254.198,0.0591,0.031,0.0265,4278.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-04",14,12.23,911.88,,0.003,0.001,497.025,0.0591,0.04,0.0174,8364.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-06",6,4.71,387.02,,0.001,0.001,200.842,0.0592,0.02,0.0135,3378.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-07",8,6.46,465.33,,0.001,0.001,250.84,0.0591,0.022,0.015,4220.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-08",5,3.48,275.64,,0.001,0.001,145.816,0.059,0.015,0.0324,2454.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-09",5,3.23,249.71,,0.001,0.001,133.047,0.059,0.015,0.0312,2239.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-11",6,4.21,335.63,,0.001,0.001,178.672,0.0592,0.017,0.0265,3005.185,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-15",4,3.48,292.2,,0.001,0.001,155.62,0.059,0.017,0.0165,2617.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-16",4,2.23,177.71,,0,0.001,94.18,0.059,0.013,0.036,1584.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-17",2,1.71,105.22,,0,0.001,59.276,0.059,0.01,0.018,997.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-18",9,8.17,713.43,,0.002,0.001,371.626,0.059,0.03,0.0146,6255.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-19",10,6.46,453.95,,0.001,0.001,248.57,0.059,0.026,0.0301,4181.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-20",7,5.23,439.01,,0.001,0.001,230.461,0.0593,0.02,0.0233,3876.059,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-21",5,3.48,302.96,,0.001,0.001,158.066,0.059,0.015,0.0292,2660.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-22",9,5.96,462.16,,0.001,0.001,245.327,0.0593,0.027,0.023,4129.175,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-23",5,3.73,322.14,,0.001,0.001,167.477,0.059,0.017,0.0302,2817.869,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-24",8,6.33,544.27,,0.001,0.001,284.891,0.0591,0.03,0.0265,4791.433,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-25",11,8.09,670.71,,0.002,0.001,349.898,0.0593,0.034,0.0197,5887.005,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-26",5,3.46,270.94,,0.001,0.001,144.018,0.059,0.024,0.0404,2422.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-27",5,3.48,308.58,,0.001,0.001,160.824,0.0592,0.018,0.0336,2704.802,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-28",8,4.71,400.39,,0.001,0.001,208.502,0.0591,0.026,0.0375,3508.879,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-29",5,3.23,256.84,,0.001,0.001,136.599,0.0592,0.013,0.0302,2298.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-30",8,5.21,429.14,,0.001,0.001,224.514,0.0591,0.029,0.0248,3777.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-10-31",7,5.98,534.28,,0.001,0.001,276.914,0.059,0.022,0.011,4660.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-01",7,5.23,450.01,,0.001,0.001,235.206,0.0591,0.02,0.0254,3956.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-02",6,3.98,325.64,,0.001,0.001,169.778,0.059,0.021,0.0302,2857.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-03",5,3.23,262.68,,0.001,0.001,138.901,0.0592,0.016,0.0306,2336.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-04",4,3.1,279.24,,0.001,0.001,144.054,0.059,0.016,0.0145,2423.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-05",10,8.46,685.9,,0.002,0.001,359.428,0.059,0.03,0.0202,6048.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-06",9,6.96,527.92,,0.001,0.001,280.644,0.0592,0.03,0.0168,4721.959,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-07",5,3.23,285.71,,0.001,0.001,143.712,0.0592,0.018,0.034,2418.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-08",8,6.73,564.26,,0.001,0.001,291.08,0.059,0.027,0.0164,4900.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-09",11,7.96,621.93,,0.002,0.001,327.26,0.059,0.032,0.023,5506.137,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-10",9,6.46,556.72,,0.001,0.001,287.054,0.0592,0.031,0.0177,4830.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-11",7,5.23,384.21,,0.001,0.001,208.107,0.0594,0.02,0.0249,3501.123,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-12",8,4.96,380.46,,0.001,0.001,202.192,0.0591,0.027,0.0311,3403.859,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-13",7,5.21,446.88,,0.001,0.001,231.178,0.059,0.023,0.02,3890.149,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-14",5,3.73,333.01,,0.001,0.001,169.726,0.059,0.016,0.0186,2855.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-15",7,5.23,473.01,,0.001,0.001,243.244,0.059,0.023,0.0274,4094.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-17",5,3.73,329.95,,0.001,0.001,171.186,0.059,0.017,0.0204,2882.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-18",5,3.2,265.49,,0.001,0.001,138.842,0.059,0.024,0.0352,2337.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-19",9,6.23,420.61,,0.001,0.001,230.333,0.0592,0.024,0.0233,3876.253,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-20",5,3.73,304.24,,0.001,0.001,160.553,0.059,0.017,0.0308,2700.293,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-21",6,4.48,324.18,,0.001,0.001,175.744,0.059,0.018,0.0273,2956.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-22",5,4.23,356.6,,0.001,0.001,186.46,0.059,0.015,0.013,3138.287,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-23",4,2.73,229.58,,0.001,0.001,118.779,0.0593,0.012,0.016,1998.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-24",8,5.94,482.44,,0.001,0.001,254.004,0.0593,0.024,0.0233,4274.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-25",5,3.17,195.15,,0.001,0.001,109.898,0.0592,0.018,0.0378,1848.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-26",5,3.23,264.88,,0.001,0.001,139.531,0.0592,0.018,0.036,2347.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-27",6,4.48,230.8,,0.001,0.001,137.941,0.059,0.014,0.018,2321.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-28",4,2.46,220.58,,0.001,0.001,112.92,0.059,0.016,0.043,1901.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-29",5,3.48,303.94,,0.001,0.001,157.4,0.0592,0.017,0.0336,2648.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-11-30",4,2.46,217.12,,0.001,0.001,111.752,0.059,0.015,0.0393,1880.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-01",8,5.44,416.69,,0.001,0.001,222.17,0.0591,0.032,0.03,3736.26,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-02",4,2.71,244.8,,0.001,0.001,126.929,0.0593,0.017,0.0258,2135.089,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-03",6,4.44,341.19,,0.001,0.001,181.868,0.059,0.026,0.025,3059.263,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-04",6,3.17,227.65,,0.001,0.001,122.215,0.0592,0.022,0.0533,2057.041,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-05",4,2.46,195.62,,0.001,0.001,102.974,0.0593,0.012,0.0395,1732.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-06",5,3.71,337.36,,0.001,0.001,171.498,0.0592,0.02,0.0354,2885.993,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-07",6,4.46,390.76,,0.001,0.001,202.13,0.0592,0.02,0.0298,3399.854,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-08",6,3.98,297.62,,0.001,0.001,158.892,0.059,0.029,0.0483,2675.062,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-09",10,7.17,480.62,,0.001,0.001,263.989,0.059,0.029,0.0237,4441.805,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-10",5,4.21,340.27,,0.001,0.001,177.327,0.0592,0.016,0.0122,2981.986,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-11",11,8.44,648.58,,0.002,0.001,344.605,0.0591,0.034,0.0202,5799.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-12",7,6.21,582.13,,0.001,0.001,291.06,0.059,0.026,0.0111,4897.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-13",6,4.21,359.26,,0.001,0.001,187.289,0.0592,0.016,0.0268,3153.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-14",9,6.96,442.25,,0.001,0.001,247.718,0.0592,0.025,0.0137,4166.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-15",11,8.19,657.3,,0.002,0.001,345.385,0.0592,0.033,0.0302,5810.009,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-16",12,9.92,868.08,,0.002,0.001,441.602,0.0591,0.041,0.0211,7429.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-17",4,2.21,185.82,,0,0.001,96.584,0.059,0.011,0.0355,1625.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-18",6,4.19,346.63,,0.001,0.001,180.288,0.0592,0.024,0.0332,3032.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-19",10,6.44,430.77,,0.001,0.001,236.865,0.0591,0.026,0.0336,3986.212,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-20",6,4.23,384.16,,0.001,0.001,197.235,0.0593,0.02,0.0293,3317.89,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-21",5,3.23,263.81,,0.001,0.001,137.264,0.0592,0.016,0.0318,2309.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-23",5,3.23,267.88,,0.001,0.001,139.595,0.0592,0.016,0.0328,2349.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-24",6,4.23,344.04,,0.001,0.001,176.539,0.059,0.017,0.0283,2970.893,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-25",9,7.21,665.39,,0.002,0.001,339.007,0.059,0.024,0.02,5704.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-26",13,10.21,942.74,,0.002,0.001,477.63,0.059,0.04,0.0185,8036.543,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-27",4,2.46,212.62,,0.001,0.001,109.22,0.059,0.02,0.0565,1837.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-28",5,3.46,270.66,,0.001,0.001,138.998,0.0592,0.02,0.019,2339.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-06",8,7.82,558.82,,0.002,0.001,305.674,0.059,0.023,0.01,5144.576,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-07",2,1.13,57.04,,0,0.001,34.282,0.0595,0.002,0.0075,576.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-15",4,2.96,233.41,,0.001,0.001,122.559,0.059,0.011,0.0118,2063.343,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-17",3,1.4,102.44,,0,0.0007,53.754,0.059,0.01,0.0107,904.362,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-20",3,1.46,84.09,,0,0.001,47.7,0.0593,0.007,0.0237,802.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-29",3,1.9,166.8,,0,0.0007,85.62,0.0593,0.012,0.011,1440.47,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-30",3,1.46,83.1,,0,0.001,47.264,0.0593,0.009,0.0487,795.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-01-31",3,2.71,144.63,,0,0.001,84.72,0.0593,0.01,0.014,1424.397,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-03",5,3.96,317.24,,0.001,0.001,167.47,0.059,0.016,0.0122,2817.951,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-04",9,7.44,602.1,,0.002,0.001,314.907,0.059,0.028,0.0236,5298.063,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-05",10,7.19,620.82,,0.002,0.001,320.366,0.0591,0.029,0.0204,5389.027,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-06",11,8.21,735.66,,0.002,0.001,379.333,0.0591,0.034,0.0214,6384.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-08",6,3.17,170.94,,0.001,0.001,99.507,0.0592,0.013,0.0455,1674.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-09",6,4.96,423.41,,0.001,0.001,219.542,0.059,0.017,0.0107,3695.153,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-10",4,3.23,243.55,,0.001,0.001,130.189,0.059,0.013,0.0125,2190.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-11",6,4.96,396.54,,0.001,0.001,207.943,0.059,0.017,0.0108,3501.558,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-12",6,4.47,401.07,,0.001,0.001,205.851,0.0592,0.017,0.0165,3464.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-27",1,0.2,0,,0,0.001,1.42,0.06,0.001,0.126,23.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-28",6,3.71,215.57,,0.001,0.001,122.828,0.0592,0.017,0.0193,2067.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-02",5,4.21,336.41,,0.001,0.001,176.146,0.059,0.015,0.0112,2963.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-03",7,6.83,534.5,,0.001,0.001,282.134,0.059,0.021,0.01,4747.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-04",2,1.13,56.91,,0,0.001,33.365,0.0595,0.002,0.007,561.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-09",2,1.46,127,,0,0.001,65.75,0.059,0.011,0.0235,1106.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-10",7,6.83,488.5,,0.001,0.001,262.785,0.059,0.019,0.0096,4423.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-11",8,6.09,400.06,,0.001,0.001,223.295,0.059,0.018,0.0095,3758.397,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-12",11,7.75,697.09,,0.002,0.001,354.488,0.059,0.032,0.0269,5964.601,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-13",20,19.83,1193.42,,0.003,0.001,682.519,0.0591,0.045,0.0078,11487.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-14",14,12.28,761.9,,0.002,0.001,433.455,0.0591,0.034,0.01,7293.617,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-15",7,5.09,421.19,,0.001,0.001,219.308,0.059,0.019,0.0103,3689.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-16",6,4.96,403.56,,0.001,0.001,210.666,0.059,0.016,0.0102,3545.833,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-17",4,2.96,206.24,,0.001,0.001,111.217,0.059,0.012,0.0133,1872.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-18",3,1.46,120.34,,0,0.001,61.88,0.0597,0.01,0.0473,1040.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-19",4,2.96,213.32,,0.001,0.001,114.881,0.0593,0.011,0.012,1933.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-20",5,2.94,220.96,,0.001,0.001,118.15,0.0592,0.015,0.0336,1989.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-28",4,2.96,205.28,,0.001,0.001,111.965,0.059,0.011,0.0123,1884.396,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-30",3,1.73,83.91,,0,0.001,50.345,0.0593,0.008,0.026,846.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-03-31",4,2.48,171.38,,0,0.001,91.689,0.059,0.013,0.0218,1544.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-01",4,2.71,244.17,,0.001,0.001,124.429,0.059,0.014,0.0353,2093.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-02",3,1.96,168.64,,0,0.001,86.111,0.059,0.012,0.0253,1449.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-03",2,1.46,129.34,,0,0.001,65.344,0.059,0.011,0.023,1099.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-04",4,2.75,254.9,,0.001,0.001,129.86,0.059,0.015,0.021,2185.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-05",11,9.48,868.83,,0.002,0.001,440.144,0.0591,0.032,0.0123,7403.749,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-06",2,1.48,104.32,,0,0.001,55.696,0.059,0.008,0.02,936.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-07",4,2.71,186.35,,0.001,0.001,100.241,0.059,0.012,0.035,1685.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-08",2,1.46,100.96,,0,0.001,54.297,0.059,0.009,0.017,913.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-09",11,9.91,885.96,,0.002,0.001,450.934,0.059,0.036,0.0101,7585.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-13",4,2.96,195.41,,0.001,0.001,106.742,0.059,0.011,0.0125,1796.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-14",5,4.2,346.04,,0.001,0.001,179.39,0.059,0.015,0.0116,3018.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-15",3,2,133.85,,0,0.001,73.57,0.059,0.009,0.0143,1238.295,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-16",3,2.21,196.91,,0.001,0.001,100.725,0.059,0.013,0.014,1694.182,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-22",4,2.73,189.31,,0.001,0.001,102.091,0.059,0.014,0.0153,1718.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-23",3,1.96,139.11,,0,0.001,74.865,0.059,0.008,0.0127,1259.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-24",4,3.21,214.56,,0.001,0.001,118.617,0.059,0.011,0.012,1996.943,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-25",2,1.71,125.28,,0,0.001,67.476,0.059,0.009,0.018,1135.253,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-29",3,1.46,115.3,,0,0.001,61.114,0.059,0.01,0.044,1027.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-04",4,3.21,242.2,,0.001,0.001,128.793,0.0593,0.012,0.0123,2165.887,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-05",7,6.23,483.84,,0.001,0.001,254.622,0.0593,0.019,0.0096,4282.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-06",2,1.58,97,,0,0.001,54.059,0.059,0.007,0.0165,909.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-07",3,1.48,104.56,,0,0.001,55.836,0.059,0.009,0.0443,939.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-09",7,5.71,445.59,,0.001,0.001,233.353,0.059,0.02,0.0226,3927.673,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-13",6,5.1,309.8,,0.001,0.001,172.77,0.0592,0.016,0.027,2905.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-14",1,0.13,0.78,,0,0.001,1.3,0.059,0,0.007,21.957,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-16",5,3.46,307.16,,0.001,0.001,156.984,0.059,0.015,0.0296,2642.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-25",5,3.46,320.4,,0.001,0.001,164.27,0.059,0.016,0.0302,2762.682,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-26",9,8.08,597.32,,0.002,0.001,322.984,0.0591,0.024,0.0198,5433.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-27",4,2.59,209.43,,0.001,0.001,110.062,0.059,0.014,0.0148,1851.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-28",3,1.71,124.35,,0,0.001,66.98,0.059,0.011,0.0483,1127.891,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-29",5,3.18,213.11,,0.001,0.001,117.432,0.059,0.013,0.0164,1975.407,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-30",10,8.73,506.05,,0.001,0.001,292.063,0.0593,0.022,0.0182,4913.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-05-31",7,6.08,431.48,,0.001,0.001,236.356,0.0593,0.02,0.0234,3975.9,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-01",3,1.59,116.95,,0,0.001,61.488,0.059,0.009,0.0137,1034.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-02",5,3.71,319.23,,0.001,0.001,165.651,0.059,0.018,0.0308,2788.607,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-03",4,3.21,254.71,,0.001,0.001,135.463,0.0593,0.016,0.0153,2278.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-04",3,2.23,120.89,,0,0.001,70.607,0.0593,0.008,0.0163,1188.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-08",6,4.23,378.44,,0.001,0.001,194.643,0.059,0.018,0.0298,3275.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-09",4,2.96,275.32,,0.001,0.001,139.334,0.059,0.016,0.016,2344.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-10",6,5.21,408.04,,0.001,0.001,216.484,0.0592,0.017,0.0155,3644.165,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-11",7,6.33,491.39,,0.001,0.001,263.757,0.059,0.023,0.0151,4435.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-12",1,0.13,1.04,,0,0.001,1.456,0.06,0,0.007,24.466,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-14",2,0.15,6.95,,0,0.001,4.03,0.0595,0.003,0.1035,67.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-16",14,12.25,1004.05,,0.003,0.001,525.435,0.0591,0.041,0.0161,8839.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-20",4,2.48,224.68,,0.001,0.001,114.762,0.059,0.013,0.0345,1931.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-23",4,2.96,272.16,,0.001,0.001,139.706,0.059,0.016,0.015,2349.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-24",4,2.46,176.76,,0,0.001,95.754,0.0593,0.009,0.0333,1612.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-25",3,1.48,100.22,,0,0.001,54.698,0.059,0.008,0.0423,920.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-26",5,3.48,305.82,,0.001,0.001,157.804,0.059,0.014,0.029,2655.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-27",5,3.96,347.93,,0.001,0.001,179.708,0.0592,0.018,0.0112,3023.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-28",4,2.71,242.69,,0.001,0.001,124.374,0.059,0.014,0.0143,2092.907,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-02",7,6.1,451.5,,0.001,0.001,244.67,0.059,0.021,0.0229,4115.71,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-03",9,7.21,498.18,,0.001,0.001,275.197,0.059,0.022,0.0193,4630.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-04",12,10.71,641.67,,0.002,0.001,368.376,0.0592,0.028,0.0098,6199.339,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-05",6,4.09,359.56,,0.001,0.001,186.733,0.059,0.018,0.0263,3143.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-06",5,3.96,373.69,,0.001,0.001,191.406,0.059,0.019,0.0184,3220.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-07",6,4.48,422.2,,0.001,0.001,215.974,0.059,0.02,0.026,3634.746,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-08",3,1.46,125.06,,0,0.001,64.819,0.0593,0.01,0.0247,1091.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-09",10,9.08,691.16,,0.002,0.001,372.328,0.0591,0.029,0.0181,6265.46,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-10",9,6.84,652.6,,0.002,0.001,333.149,0.0592,0.029,0.011,5604.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-11",8,6.96,628.96,,0.002,0.001,323.44,0.059,0.025,0.0206,5442.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-12",7,6.23,560.74,,0.001,0.001,289.079,0.059,0.025,0.0117,4863.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-13",3,1.46,69.44,,0,0.001,42.166,0.059,0.006,0.0417,710.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-14",4,2.46,201.54,,0.001,0.001,105.937,0.059,0.012,0.0203,1781.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-15",4,2.73,239.4,,0.001,0.001,123.296,0.059,0.018,0.0303,2074.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-16",5,3.21,290.1,,0.001,0.001,149.17,0.059,0.015,0.0296,2508.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-17",5,3.46,310.3,,0.001,0.001,159.17,0.0592,0.016,0.029,2679.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-18",5,3.48,319.58,,0.001,0.001,163.508,0.059,0.016,0.0294,2750.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-21",3,1.58,128.26,,0,0.001,66.72,0.059,0.011,0.0457,1122.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-22",6,4.23,325.58,,0.001,0.001,173.129,0.0593,0.018,0.027,2912.269,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-23",3,1.46,115.4,,0,0.001,60.648,0.059,0.01,0.0453,1021.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-24",4,2.23,196.35,,0.001,0.001,101.393,0.0593,0.013,0.0353,1706.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-25",8,7.1,559.6,,0.002,0.001,297.84,0.0591,0.026,0.0215,5010.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-26",8,5.34,457.77,,0.001,0.001,237.515,0.059,0.022,0.0213,3995.372,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-27",8,6.85,555.56,,0.001,0.001,292.731,0.059,0.026,0.0125,4924.913,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-28",5,3.73,325.48,,0.001,0.001,168.441,0.0592,0.016,0.029,2832.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-29",4,3.21,276.64,,0.001,0.001,144.343,0.059,0.016,0.021,2429.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-30",6,5.85,557.45,,0.001,0.001,282.895,0.059,0.024,0.0102,4761.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-07-31",10,8.21,746.31,,0.002,0.001,385.007,0.059,0.028,0.0173,6478.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-05",4,2.48,222.68,,0.001,0.001,115.348,0.059,0.017,0.0365,1941.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-06",4,2.23,192.52,,0.001,0.001,100.295,0.0593,0.012,0.0353,1687.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-07",5,3.48,312.78,,0.001,0.001,161.878,0.059,0.017,0.031,2723.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-08",5,3.5,326,,0.001,0.001,167.43,0.059,0.017,0.0294,2817.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-09",4,2.73,243.37,,0.001,0.001,125.38,0.059,0.013,0.035,2109.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-10",3,1.96,166.62,,0,0.001,86.908,0.059,0.011,0.0163,1462.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-11",3,1.48,116.76,,0,0.001,61.684,0.059,0.01,0.047,1037.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-12",8,6.96,560.65,,0.002,0.001,298.262,0.059,0.024,0.0096,5018.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-13",8,6.71,509.97,,0.001,0.001,274.999,0.059,0.021,0.0105,4629.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-14",10,8.48,742.5,,0.002,0.001,385.462,0.0591,0.03,0.0185,6488.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-15",6,4.74,299.48,,0.001,0.001,168.73,0.0592,0.017,0.0118,2840.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-17",11,9.71,775.7,,0.002,0.001,413.052,0.0591,0.031,0.0096,6949.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-18",10,9.26,884.8,,0.002,0.001,453.998,0.059,0.034,0.0091,7638.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-19",2,1.82,143.66,,0,0.001,76.974,0.059,0.01,0.016,1295.188,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-21",4,2.23,204.55,,0.001,0.001,106.436,0.059,0.013,0.035,1790.178,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-22",7,5.46,463.4,,0.001,0.001,244.032,0.059,0.022,0.0233,4104.79,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-23",4,3.71,347.01,,0.001,0.001,180.157,0.059,0.018,0.0123,3031.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-24",8,6.96,678.44,,0.002,0.001,348.12,0.059,0.029,0.0214,5858.1,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-25",6,4.98,410.87,,0.001,0.001,217.604,0.059,0.018,0.0155,3661.011,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-26",3,1.46,72.82,,0,0.001,44.478,0.059,0.007,0.0427,747.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-27",7,6.71,637.67,,0.002,0.001,327.235,0.059,0.028,0.0106,5508.326,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-28",6,4.94,364.26,,0.001,0.001,198.554,0.059,0.018,0.0132,3340.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-03",5,3.73,298.93,,0.001,0.001,160.89,0.059,0.016,0.0292,2706.741,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-04",7,6.48,581.85,,0.002,0.001,305.427,0.059,0.026,0.0104,5141.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-05",9,8.23,745.9,,0.002,0.001,390.842,0.059,0.032,0.0098,6577.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-06",2,0.61,16.64,,0,0.001,12.199,0.059,0.005,0.0545,205.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-10",7,4.25,385.2,,0.001,0.0009,198.08,0.0593,0.018,0.018,3334.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-11",6,4.23,380.51,,0.001,0.001,196.337,0.059,0.018,0.0265,3304.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-12",4,2.71,240.77,,0.001,0.001,125.024,0.059,0.015,0.036,2104.914,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-13",6,4.46,410.1,,0.001,0.001,210.688,0.0592,0.019,0.0252,3543.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-14",6,4.46,397.24,,0.001,0.001,205.798,0.0592,0.018,0.0248,3462.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-15",9,7.08,581.53,,0.002,0.001,308.988,0.0591,0.037,0.0217,5198.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-16",8,5.34,473.96,,0.001,0.001,245.383,0.0591,0.019,0.0204,4127.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-17",7,5.46,485.5,,0.001,0.001,251.726,0.059,0.02,0.0216,4237.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-18",13,12.71,949.96,,0.003,0.001,514.951,0.0591,0.038,0.0087,8664.781,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-19",8,6.23,511.44,,0.001,0.001,270.213,0.0591,0.022,0.0176,4547.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-20",9,8.1,649.6,,0.002,0.001,344.85,0.059,0.026,0.0161,5801.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-21",7,4.36,391.49,,0.001,0.001,201.556,0.0593,0.018,0.0186,3391.987,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-22",4,2.48,209.38,,0.001,0.001,109.466,0.059,0.012,0.0298,1842.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-23",7,5.21,432.1,,0.001,0.001,227.397,0.0591,0.02,0.0219,3826.199,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-24",4,2.23,191.48,,0.001,0.001,99.199,0.0593,0.012,0.0303,1669.865,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-25",5,3.48,320.2,,0.001,0.001,165.738,0.059,0.016,0.0244,2787.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-26",5,3.48,310.92,,0.001,0.001,160.602,0.059,0.017,0.027,2703.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-27",5,3.48,301.12,,0.001,0.001,157.972,0.0594,0.015,0.0272,2658.184,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-28",5,3.98,317.96,,0.001,0.001,171.394,0.0592,0.014,0.026,2882.234,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-29",3,1.96,147.78,,0,0.001,80.063,0.0593,0.01,0.013,1347.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-09-30",4,2.96,241.32,,0.001,0.001,128.52,0.059,0.011,0.013,2163.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-01",5,4.05,207.8,,0.001,0.001,123.72,0.0592,0.011,0.0124,2080.82,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-02",5,3.73,245.04,,0.001,0.001,138.013,0.059,0.015,0.018,2323.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-03",5,4.71,453.82,,0.001,0.001,232.595,0.059,0.022,0.0116,3915.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-04",8,6.46,606.1,,0.002,0.001,314.218,0.059,0.024,0.0193,5286.716,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-05",6,5.48,499.86,,0.001,0.001,258.921,0.059,0.023,0.0107,4356.488,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-06",15,11.96,889.39,,0.002,0.001,481.269,0.0591,0.038,0.0163,8096.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-07",5,3.21,273.99,,0.001,0.001,142.728,0.059,0.014,0.0282,2401.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-08",5,3.96,363,,0.001,0.001,188.516,0.0592,0.016,0.0282,3170.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-09",6,4.5,399.5,,0.001,0.001,208.63,0.059,0.018,0.0238,3513.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-10",6,4.21,386.28,,0.001,0.001,201.048,0.0592,0.018,0.0238,3382.727,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-11",6,4.23,382.54,,0.001,0.001,199.959,0.059,0.019,0.0245,3365.438,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-12",7,5.73,426.89,,0.001,0.001,231.269,0.059,0.021,0.0151,3892.649,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-13",8,6.25,412.45,,0.001,0.001,232.685,0.059,0.017,0.0195,3915.245,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-14",6,4.71,384.33,,0.001,0.001,206.032,0.059,0.017,0.0248,3468.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-15",5,4.46,358.5,,0.001,0.001,193.574,0.059,0.018,0.013,3257.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-16",2,1.71,96.04,,0,0.001,56.786,0.059,0.008,0.016,954.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-17",2,1.73,107.73,,0,0.001,61.693,0.059,0.01,0.017,1039.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-18",5,4.21,396.97,,0.001,0.001,205.84,0.059,0.022,0.0152,3463.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-19",4,2.71,236.05,,0.001,0.001,124.55,0.0593,0.014,0.0138,2095.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-20",4,2.98,204.76,,0.001,0.001,114.652,0.0593,0.012,0.0115,1928.083,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-21",7,4.71,382.38,,0.001,0.001,204.059,0.0591,0.021,0.0253,3432.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-22",5,3.23,281.51,,0.001,0.001,147.713,0.0594,0.014,0.0284,2486.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-23",6,4.98,395.52,,0.001,0.001,212.412,0.059,0.017,0.024,3573.934,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-24",3,1.96,152.5,,0,0.001,82.513,0.059,0.012,0.0253,1387.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-25",7,5.98,508.7,,0.001,0.001,268.966,0.059,0.022,0.0109,4525.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-26",7,4.21,284.68,,0.001,0.001,159.203,0.0591,0.021,0.0273,2680.497,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-27",5,3.48,308.18,,0.001,0.001,161.906,0.0592,0.017,0.0314,2724.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-28",10,6.96,602.04,,0.002,0.001,316.16,0.0592,0.031,0.0364,5319.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-29",5,3.23,267.12,,0.001,0.001,142.258,0.059,0.014,0.0264,2393.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-30",4,2.25,204.7,,0.001,0.001,106.155,0.059,0.014,0.0333,1785.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-10-31",6,4.48,430.82,,0.001,0.001,222.351,0.059,0.021,0.0165,3740.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-01",7,5.46,483.88,,0.001,0.001,252.664,0.0591,0.021,0.015,4252.134,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-02",5,3.19,206.71,,0.001,0.001,115.652,0.0592,0.014,0.0224,1946.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-03",4,2.73,189.71,,0.001,0.001,105.551,0.059,0.01,0.013,1775.978,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-04",3,2.71,214.58,,0.001,0.001,115.488,0.059,0.012,0.0137,1942.961,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-05",7,5.71,491.78,,0.001,0.001,255.862,0.0591,0.022,0.0247,4305.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-06",5,3.46,262.54,,0.001,0.001,141.75,0.059,0.013,0.0282,2385.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-07",4,2.21,190.07,,0,0.001,96.787,0.0595,0.013,0.0375,1628.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-08",5,4.23,367.17,,0.001,0.001,190.709,0.059,0.017,0.0108,3209.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-09",9,5.94,439.59,,0.001,0.001,238.446,0.059,0.024,0.0303,4011.722,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-10",8,5.71,477.29,,0.001,0.001,250.549,0.059,0.026,0.0166,4217.101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-11",12,9.21,555.14,,0.002,0.001,318.836,0.0591,0.028,0.0173,5364.133,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-12",7,4.17,301.98,,0.001,0.001,164.726,0.059,0.018,0.0211,2772.647,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-13",5,3.21,284.84,,0.001,0.001,148.682,0.0592,0.013,0.0286,2500.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-14",4,2.21,190.31,,0,0.001,98.517,0.059,0.011,0.032,1658.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-15",6,4.73,411.51,,0.001,0.001,215.876,0.059,0.02,0.0283,3634.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-17",5,3.46,313.46,,0.001,0.001,163.47,0.0592,0.016,0.0292,2750.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-18",8,5.19,419.08,,0.001,0.001,222.037,0.059,0.022,0.0263,3735.879,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-19",3,1.46,117.82,,0,0.001,63.014,0.0597,0.01,0.0413,1059.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-20",5,3.48,286.94,,0.001,0.001,152.876,0.059,0.019,0.0302,2572.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-21",4,2.71,218.36,,0.001,0.001,116.705,0.059,0.013,0.035,1963.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-22",5,3.46,305.26,,0.001,0.001,159.776,0.059,0.015,0.0284,2688.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-24",8,5.94,470.48,,0.001,0.001,251.824,0.0591,0.025,0.0133,4237.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-25",3,1.96,129.38,,0,0.001,72.106,0.0593,0.008,0.0157,1212.642,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-26",5,3.23,264.61,,0.001,0.001,140.39,0.059,0.016,0.0306,2362.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-27",2,1.46,68.02,,0,0.001,42.304,0.059,0.007,0.023,712.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-11-30",3,1.46,113.44,,0,0.001,60.502,0.059,0.01,0.0473,1017.214,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-01",6,3.19,263.04,,0.001,0.001,137.902,0.0592,0.022,0.0432,2319.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-03",4,2.46,176.76,,0,0.001,97.636,0.059,0.011,0.0368,1643.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-04",12,9.83,637.37,,0.002,0.001,356.619,0.0592,0.032,0.0252,5998.297,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-05",5,3.36,205.33,,0.001,0.001,116.794,0.0592,0.011,0.0114,1966.264,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-06",3,1.96,156.92,,0,0.001,83.08,0.059,0.01,0.0447,1399.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-07",4,2.98,246.2,,0.001,0.001,129.944,0.059,0.013,0.0363,2186.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-08",8,5.69,331.27,,0.001,0.001,192.344,0.0593,0.022,0.0269,3235.389,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-09",3,2.46,124.22,,0,0.001,75.712,0.059,0.01,0.0167,1274.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-10",6,4.71,402.57,,0.001,0.001,209.655,0.059,0.018,0.0238,3528.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-11",6,4.69,387.86,,0.001,0.001,203.927,0.059,0.022,0.015,3431.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-12",6,4.46,375.8,,0.001,0.001,194.22,0.0592,0.018,0.0235,3267.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-13",6,4.21,380.86,,0.001,0.001,198.084,0.0592,0.016,0.0255,3334.077,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-14",7,5.44,377.4,,0.001,0.001,208.236,0.059,0.02,0.0143,3504.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-15",11,7.71,649.26,,0.002,0.001,340.179,0.0591,0.031,0.0256,5722.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-16",11,8.94,808.96,,0.002,0.001,411.874,0.0591,0.036,0.0196,6930.281,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-17",4,2.21,185.42,,0,0.001,97.182,0.059,0.01,0.0305,1635.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-18",4,2.4,214.12,,0.001,0.001,111.456,0.059,0.013,0.0333,1875.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-19",6,4.94,308.98,,0.001,0.001,176.528,0.059,0.019,0.013,2971.301,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-20",3,1.46,108.6,,0,0.001,58.628,0.059,0.008,0.0423,986.572,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-21",5,3.21,265.31,,0.001,0.001,139.057,0.059,0.014,0.0284,2339.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-22",7,5.2,353.42,,0.001,0.001,196.103,0.059,0.019,0.0236,3298.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-23",4,2.48,186.14,,0.001,0.001,100.042,0.059,0.012,0.03,1684.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-24",5,3.23,241.38,,0.001,0.001,127.882,0.0594,0.013,0.03,2151.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-25",4,2.21,187.99,,0,0.001,98.276,0.059,0.011,0.0328,1653.618,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-26",12,8.73,596.63,,0.002,0.001,326.717,0.0591,0.029,0.0197,5496.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-27",7,5.21,362.31,,0.001,0.001,199.504,0.059,0.018,0.0223,3356.281,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-28",3,1.73,116.98,,0,0.001,62.68,0.0593,0.009,0.0167,1054.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT2",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-06",5,3.98,310.26,,0.001,0.001,164.468,0.0592,0.015,0.0128,2767.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-07",3,1.46,84.88,,0,0.001,48.114,0.0593,0.007,0.0247,809.697,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-17",4,2.71,144.68,,0,0.001,83.961,0.0595,0.01,0.0158,1411.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-20",3,1.46,85.38,,0,0.001,48.178,0.059,0.008,0.0433,810.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-26",3,1.46,90.3,,0,0.001,49.686,0.059,0.009,0.0457,836.66,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-30",3,1.46,83.84,,0,0.001,47.28,0.059,0.01,0.052,795.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-03",14,11.71,768.89,,0.002,0.001,422.571,0.059,0.036,0.0116,7113.017,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-04",8,6.23,412.05,,0.001,0.001,225.729,0.0591,0.024,0.0148,3799.72,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-05",10,6.4,550.3,,0.001,0.001,282.138,0.059,0.032,0.033,4749.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-06",11,7.46,695.1,,0.002,0.001,352.535,0.059,0.034,0.0284,5932.22,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-09",14,11.19,767.89,,0.002,0.001,415.743,0.0591,0.037,0.0176,6995.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-10",4,3.23,239.96,,0.001,0.001,127.992,0.0593,0.012,0.0125,2152.483,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-11",6,5.22,433.72,,0.001,0.001,224.644,0.0592,0.019,0.011,3778.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-12",6,4.98,426.68,,0.001,0.001,220.268,0.0592,0.018,0.0107,3704.429,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-15",5,3.96,334.73,,0.001,0.001,171.625,0.059,0.015,0.012,2887.687,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-17",5,4.21,351.41,,0.001,0.001,181.39,0.059,0.016,0.0114,3052.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-19",5,3.96,322.24,,0.001,0.001,167.217,0.0592,0.014,0.0114,2812.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-20",8,7.83,539.99,,0.001,0.001,293.864,0.059,0.022,0.0099,4945.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-21",2,1.13,53.91,,0,0.001,32.778,0.059,0.002,0.007,552.383,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-22",1,0.17,0,,0,0.001,1.224,0.06,0.001,0.107,20.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-28",1,0.25,0,,0,0.001,1.725,0.059,0.002,0.135,29.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-01",8,7.83,550.33,,0.001,0.001,294.917,0.0591,0.022,0.0099,4959.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-02",7,5.36,390.14,,0.001,0.001,207.969,0.0591,0.018,0.0104,3499.981,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-04",3,2.46,133.13,,0,0.001,78.235,0.0597,0.008,0.013,1315.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-05",3,2.48,147.16,,0,0.001,82.629,0.059,0.009,0.014,1389.985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-08",1,0.4,5.6,,0,0.001,5.64,0.059,0.005,0.102,95.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-09",3,2.21,201.72,,0.001,0.001,103.14,0.059,0.017,0.018,1735.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-10",8,7.83,564.16,,0.002,0.001,303.498,0.059,0.022,0.0091,5107.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-11",7,5.09,357.15,,0.001,0.001,194.225,0.0591,0.017,0.0103,3266.187,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-12",10,8.21,696.87,,0.002,0.001,356.73,0.059,0.032,0.021,6001.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-13",12,9.92,838.72,,0.002,0.001,436.029,0.059,0.036,0.0178,7336.929,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-14",19,18.65,1143.3,,0.003,0.001,652.655,0.0591,0.045,0.0088,10980.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-15",7,5.11,418.33,,0.001,0.001,218.045,0.059,0.019,0.0107,3669.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-16",11,7.67,676.55,,0.002,0.001,346.346,0.0591,0.033,0.0282,5828.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-18",4,2.46,195.27,,0.001,0.001,100.685,0.059,0.011,0.0235,1693.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-19",6,4.96,393.77,,0.001,0.001,205.95,0.059,0.017,0.0105,3465.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-20",5,3.96,285.11,,0.001,0.001,154.797,0.0592,0.014,0.0114,2602.494,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-24",5,3.96,295.73,,0.001,0.001,157.766,0.059,0.014,0.0122,2655.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-28",5,3.21,253.63,,0.001,0.001,133.24,0.0592,0.015,0.0304,2241.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-30",3,1.71,83.88,,0,0.001,50.122,0.0597,0.009,0.029,843.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-03-31",4,3.11,182.32,,0.001,0.001,103.165,0.0595,0.012,0.0115,1735.483,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-01",4,2.93,211.78,,0.001,0.001,114.272,0.059,0.011,0.0123,1923.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-04",3,2.46,228.58,,0.001,0.001,115.514,0.059,0.016,0.02,1944.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-05",15,13.46,1230.32,,0.003,0.001,622.712,0.059,0.044,0.0112,10479.097,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-07",8,4.92,349.84,,0.001,0.001,187.031,0.0593,0.024,0.0348,3146.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-08",4,2.96,257.31,,0.001,0.001,131.453,0.0593,0.016,0.0133,2211.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-09",11,9.41,822.22,,0.002,0.001,420.606,0.059,0.037,0.0115,7078.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-13",4,2.96,192.41,,0.001,0.001,106.234,0.0595,0.011,0.0128,1787.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-14",5,4.2,347,,0.001,0.001,179.452,0.059,0.016,0.0116,3019.138,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-15",3,1.98,133.68,,0,0.001,73.485,0.059,0.009,0.0143,1236.419,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-16",4,3.46,271.9,,0.001,0.001,143.042,0.059,0.013,0.012,2407.569,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-19",4,2.96,217.24,,0.001,0.001,115.778,0.059,0.011,0.0123,1947.397,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-22",5,3.73,244.4,,0.001,0.001,134.666,0.059,0.016,0.0154,2266.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-23",7,6.83,478.33,,0.001,0.001,262.066,0.059,0.02,0.0099,4409.121,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-24",8,5.84,425.99,,0.001,0.001,229.361,0.0591,0.02,0.0139,3858.933,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-25",3,1.96,135.69,,0,0.001,74.369,0.059,0.009,0.0133,1251.101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-27",4,2.71,181.9,,0.001,0.001,100.311,0.059,0.011,0.0345,1688.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-29",5,3.96,281.24,,0.001,0.001,153.196,0.059,0.013,0.0108,2577.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-01",3,1.85,167.02,,0,0.0007,85.005,0.0593,0.013,0.0137,1430.541,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-04",7,6.83,477.5,,0.001,0.001,260.3,0.059,0.02,0.0099,4381.369,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-05",8,6.48,519.46,,0.001,0.001,271.46,0.0591,0.022,0.0108,4567.553,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-06",6,5.21,396.94,,0.001,0.001,210.727,0.059,0.017,0.0105,3546.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-07",3,1.46,103.46,,0,0.001,55.52,0.059,0.008,0.0443,934.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-08",3,1.71,153.09,,0,0.001,77.502,0.059,0.011,0.0267,1304.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-09",7,5.48,402.72,,0.001,0.001,214.908,0.0591,0.02,0.0239,3614.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-11",7,6.08,408.4,,0.001,0.001,221.492,0.0593,0.02,0.0243,3726.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-12",1,0.15,1.05,,0,0.001,1.575,0.059,0,0.009,26.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-16",6,4.71,427.01,,0.001,0.001,217.963,0.059,0.02,0.0263,3668.395,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-20",4,2.96,150.11,,0,0.001,88.903,0.059,0.01,0.0123,1495.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-21",4,2.96,226.04,,0.001,0.001,120.244,0.0593,0.011,0.0368,2022.644,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-22",3,1.46,118.68,,0,0.001,61.97,0.0593,0.01,0.0447,1041.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-25",5,3.46,319.48,,0.001,0.001,163.702,0.059,0.016,0.0306,2754.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-26",6,4.26,345.82,,0.001,0.001,182.848,0.0592,0.017,0.027,3075.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-27",6,5.21,412.42,,0.001,0.001,217.805,0.059,0.019,0.0105,3665.231,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-28",4,2.21,191.34,,0,0.001,98.871,0.0593,0.013,0.036,1662.701,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-29",6,4.96,404.99,,0.001,0.001,212.674,0.059,0.019,0.0107,3579.562,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-30",5,3.21,178.18,,0.001,0.001,103.834,0.059,0.011,0.0306,1748.052,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-05-31",7,6.08,424.56,,0.001,0.001,233.388,0.059,0.024,0.0254,3927.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-01",5,3.36,248.22,,0.001,0.001,131.4,0.059,0.015,0.0114,2212.057,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-02",6,4.48,403.92,,0.001,0.001,207.828,0.059,0.018,0.0262,3498.288,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-03",6,4.71,411.73,,0.001,0.001,213.429,0.0592,0.019,0.0282,3591.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-04",3,2.21,122.09,,0,0.001,71.368,0.059,0.008,0.0163,1202.589,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-08",6,4.21,366.36,,0.001,0.001,188.856,0.059,0.017,0.0302,3177.861,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-09",4,2.96,274.32,,0.001,0.001,138.672,0.059,0.016,0.0163,2332.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-10",9,7.18,533.36,,0.001,0.001,286.301,0.0591,0.024,0.0146,4818.081,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-11",3,1.96,170.56,,0,0.001,88.281,0.059,0.011,0.025,1485.405,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-14",4,2.21,188.26,,0,0.001,97.863,0.059,0.012,0.036,1646.541,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-16",5,3.21,264.07,,0.001,0.001,138.24,0.0592,0.016,0.0302,2325.531,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-17",18,14.46,1193.84,,0.003,0.001,625.258,0.0592,0.051,0.0201,10523.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-18",3,1.46,109.64,,0,0.001,58.66,0.059,0.008,0.0443,986.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-20",4,2.46,197.88,,0.001,0.001,103.558,0.059,0.013,0.0353,1742.244,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-21",4,2.46,209.64,,0.001,0.001,108.828,0.059,0.013,0.0355,1831.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-22",3,1.96,174.36,,0,0.001,89.228,0.059,0.012,0.0457,1501.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-23",4,2.96,272.16,,0.001,0.001,139.39,0.059,0.016,0.015,2345.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-24",4,2.48,190.68,,0.001,0.001,101.176,0.059,0.01,0.0348,1702.832,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-25",4,2.96,200.88,,0.001,0.001,110.848,0.059,0.011,0.0343,1865.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-26",4,3.23,255.72,,0.001,0.001,134.482,0.059,0.014,0.012,2264.693,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-27",4,2.73,230.67,,0.001,0.001,119.452,0.059,0.014,0.0148,2010.481,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-28",5,3.21,270.31,,0.001,0.001,140.307,0.0592,0.014,0.0294,2360.743,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-06-30",6,4.21,322.34,,0.001,0.001,172.734,0.0592,0.015,0.0255,2904.631,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-02",7,6.08,457.4,,0.001,0.001,246.724,0.0591,0.021,0.0236,4150.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-03",9,7.21,587.31,,0.002,0.001,311.357,0.059,0.026,0.0201,5239.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-04",4,1.84,111.58,,0,0.001,62.748,0.0593,0.01,0.0148,1056.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-05",8,7.46,594.7,,0.002,0.001,316.012,0.059,0.027,0.0115,5316.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-06",6,4.71,449.42,,0.001,0.001,228.932,0.059,0.021,0.0273,3851.236,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-07",6,4.46,404.56,,0.001,0.001,208.504,0.0593,0.019,0.0265,3507.25,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-08",5,3.21,289.52,,0.001,0.001,149.328,0.0592,0.015,0.0312,2512.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-09",7,5.48,444.04,,0.001,0.001,235.932,0.059,0.02,0.0233,3968.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-10",9,7.21,683.52,,0.002,0.001,349.741,0.0591,0.028,0.0207,5885.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-11",8,7.48,681.66,,0.002,0.001,350.306,0.059,0.028,0.0108,5892.728,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-12",7,5.96,551.21,,0.001,0.001,283.244,0.059,0.024,0.015,4764.783,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-13",10,7.83,535.3,,0.001,0.001,294.557,0.059,0.034,0.0262,4955.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-14",5,2.34,185.3,,0,0.001,97.795,0.0592,0.011,0.0294,1645.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-15",4,2.46,224.48,,0.001,0.001,115.434,0.059,0.013,0.0368,1942.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-16",5,3.21,287.23,,0.001,0.001,148.638,0.0592,0.015,0.0314,2501.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-17",12,9.28,631.38,,0.002,0.001,348.954,0.0591,0.03,0.0243,5871.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-18",6,3.59,313.57,,0.001,0.001,162.256,0.0592,0.015,0.0265,2730.973,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-19",4,2.21,178.31,,0,0.001,93.836,0.059,0.011,0.0368,1579.351,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-21",5,3.21,273.47,,0.001,0.001,142.25,0.059,0.015,0.0296,2392.748,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-22",6,5.83,406.19,,0.001,0.001,222.442,0.059,0.021,0.0112,3744.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-23",4,1.59,115.31,,0,0.001,62.08,0.059,0.01,0.0365,1045.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-24",4,2.21,197.42,,0.001,0.001,101.843,0.0593,0.013,0.036,1712.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-25",8,7.08,558.56,,0.002,0.001,297.68,0.059,0.024,0.0219,5010.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-26",8,5.84,507.6,,0.001,0.001,263.491,0.059,0.024,0.0113,4434.191,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-27",8,6.83,553.23,,0.001,0.001,292.578,0.059,0.025,0.0121,4924.281,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-28",7,5.21,447.52,,0.001,0.001,233.504,0.059,0.02,0.0237,3929.972,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-29",4,3.46,301.74,,0.001,0.001,156.698,0.059,0.018,0.0158,2637.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-30",6,5.83,553.72,,0.001,0.001,282.276,0.059,0.023,0.01,4748.909,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-07-31",9,7.71,712.09,,0.002,0.001,367.019,0.0591,0.028,0.0194,6175.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-03",3,2.31,135.41,,0,0.001,77.759,0.059,0.011,0.017,1308.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-05",4,2.46,223.24,,0.001,0.001,114.916,0.059,0.013,0.0335,1934.362,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-06",4,2.23,190.52,,0.001,0.001,99.733,0.059,0.013,0.0368,1678.729,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-07",5,3.46,312.26,,0.001,0.001,160.6,0.059,0.017,0.0324,2703.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-08",5,3.48,325.92,,0.001,0.001,166.428,0.0592,0.017,0.031,2799.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-09",4,2.71,240.62,,0.001,0.001,123.62,0.059,0.013,0.0368,2079.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-10",4,2.96,270.14,,0.001,0.001,138.622,0.059,0.016,0.0128,2332.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-11",5,3.23,277.44,,0.001,0.001,143.74,0.0592,0.015,0.0326,2417.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-12",7,5.96,504.04,,0.001,0.001,263.072,0.059,0.021,0.0249,4426.404,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-13",7,6.71,548.22,,0.001,0.001,289.276,0.0591,0.023,0.0101,4867.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-14",10,8.71,763.44,,0.002,0.001,396.167,0.059,0.03,0.0192,6667.35,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-15",7,5.46,433.02,,0.001,0.001,229.99,0.059,0.02,0.0233,3869.972,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-17",11,9.73,768.6,,0.002,0.001,408.599,0.0591,0.031,0.0095,6874.369,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-20",10,8.65,708.74,,0.002,0.001,373.149,0.059,0.036,0.0113,6279.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-21",9,6.34,535.45,,0.001,0.001,280.056,0.0592,0.021,0.0191,4713.275,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-22",7,5.46,459.78,,0.001,0.001,241.048,0.0591,0.023,0.024,4056.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-23",5,4.46,391.92,,0.001,0.001,205.092,0.059,0.018,0.0114,3451.219,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-24",9,8.21,786.61,,0.002,0.001,402.624,0.059,0.031,0.0096,6775.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-25",6,5.21,413.3,,0.001,0.001,220.388,0.059,0.018,0.012,3706.771,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-26",3,1.96,144.08,,0,0.001,78.054,0.059,0.011,0.0257,1313.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-27",8,6.96,663.88,,0.002,0.001,339.112,0.0591,0.029,0.0225,5704.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-28",6,4.93,361.45,,0.001,0.001,196.463,0.059,0.018,0.0125,3307.761,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-02",2,0.1,4.1,,0,0.001,2.56,0.059,0.002,0.1085,43.062,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-03",7,5.21,456.39,,0.001,0.001,239.865,0.0591,0.021,0.0227,4036.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-04",7,6.46,568.86,,0.002,0.001,298.926,0.059,0.025,0.0103,5028.73,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-05",8,7.46,673.81,,0.002,0.001,351.068,0.059,0.029,0.01,5907.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-06",2,0.6,16.92,,0,0.001,12.192,0.059,0.006,0.057,205.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-10",6,4.23,383.2,,0.001,0.001,197.151,0.059,0.018,0.0232,3317.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-11",6,4.21,380.39,,0.001,0.001,195.491,0.059,0.018,0.028,3287.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-12",10,6.96,624.86,,0.002,0.001,320.764,0.0592,0.032,0.0315,5398.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-13",9,8.08,703.32,,0.002,0.001,364.5,0.0591,0.03,0.0211,6133.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-14",7,4.59,409.45,,0.001,0.001,210.769,0.059,0.019,0.024,3547.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-15",6,4.21,383.75,,0.001,0.001,198.022,0.059,0.018,0.027,3333.884,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-16",8,6.46,596.97,,0.002,0.001,305.495,0.059,0.025,0.0135,5142.726,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-17",7,5.46,484.88,,0.001,0.001,251.004,0.059,0.021,0.025,4221.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-18",13,11.21,883.75,,0.002,0.001,470.604,0.0592,0.037,0.0168,7918.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-19",9,7.96,753.83,,0.002,0.001,384.866,0.059,0.028,0.0126,6475.743,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-20",12,10.73,841.13,,0.002,0.001,448.224,0.0591,0.033,0.0093,7541.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-21",6,4.23,395.48,,0.001,0.001,201.155,0.059,0.019,0.0265,3384.023,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-22",8,5.19,413.06,,0.001,0.001,218.386,0.0591,0.024,0.023,3672.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-23",8,6.21,486.1,,0.001,0.001,258.436,0.059,0.022,0.0224,4349.329,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-24",4,2.21,191.34,,0,0.001,98.548,0.0593,0.012,0.0385,1658.641,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-25",10,9.21,783.3,,0.002,0.001,413.221,0.059,0.033,0.0096,6953.257,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-26",5,3.48,309.28,,0.001,0.001,159.748,0.059,0.017,0.0306,2687.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-27",5,3.46,297.58,,0.001,0.001,156.428,0.059,0.016,0.0302,2632.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-28",7,5.21,423.67,,0.001,0.001,226.015,0.0593,0.019,0.0239,3803.186,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-29",3,1.98,156.77,,0,0.001,83.834,0.059,0.011,0.013,1410.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-09-30",5,3.46,283.78,,0.001,0.001,150.938,0.0592,0.014,0.0312,2539.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-01",3,2.21,108.46,,0,0.001,65.774,0.059,0.008,0.017,1106.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-02",5,3.96,261.74,,0.001,0.001,147.524,0.0592,0.016,0.0134,2481.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-03",6,5.23,488.07,,0.001,0.001,251.689,0.059,0.025,0.0122,4234.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-04",10,7.94,678.34,,0.002,0.001,357.558,0.0591,0.029,0.019,6017.408,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-06",5,3.96,354.63,,0.001,0.001,182.937,0.059,0.028,0.0176,3077.463,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-07",5,3.21,274.2,,0.001,0.001,142.878,0.059,0.02,0.033,2404.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-08",15,12.21,780.08,,0.002,0.001,444.737,0.059,0.037,0.017,7486.299,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-09",8,6.21,523.31,,0.001,0.001,277.402,0.059,0.026,0.0224,4665.391,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-10",6,4.21,371.2,,0.001,0.001,194.545,0.0592,0.019,0.0258,3273.523,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-11",7,5.21,464.31,,0.001,0.001,243.207,0.0593,0.023,0.0234,4093.263,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-12",6,4.46,336.04,,0.001,0.001,181.304,0.059,0.017,0.0267,3052.768,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-13",8,6.25,445.35,,0.001,0.001,246.93,0.059,0.021,0.0211,4155.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-14",7,5.71,515.76,,0.001,0.001,269.092,0.059,0.025,0.012,4527.554,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-15",5,4.71,351.27,,0.001,0.001,192.923,0.0592,0.018,0.0114,3246.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-16",2,1.73,95.21,,0,0.001,56.671,0.059,0.009,0.017,953.602,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-17",2,1.48,85.74,,0,0.001,50.222,0.059,0.009,0.022,844.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-18",5,3.46,309.72,,0.001,0.001,162.314,0.0592,0.018,0.0312,2731.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-19",5,3.23,282.37,,0.001,0.001,148.42,0.0594,0.017,0.0306,2498.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-20",5,3.96,327.86,,0.001,0.001,174.94,0.0592,0.017,0.0112,2943.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-21",5,3.46,290.44,,0.001,0.001,154.148,0.0592,0.015,0.0298,2593.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-23",4,2.71,216.42,,0.001,0.001,116.069,0.059,0.015,0.0365,1952.499,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-24",6,4.71,409.73,,0.001,0.001,216.316,0.059,0.023,0.0278,3639.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-25",6,4.96,410.84,,0.001,0.001,218.266,0.059,0.022,0.0138,3674.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-26",8,4.94,320.05,,0.001,0.001,181.423,0.059,0.023,0.0275,3053.446,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-27",5,3.46,307.48,,0.001,0.001,160.718,0.059,0.017,0.0338,2703.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-28",15,11.94,920.62,,0.003,0.001,495.58,0.0591,0.041,0.0229,8338.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-29",5,3.23,302.72,,0.001,0.001,155.567,0.059,0.018,0.0316,2618.468,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-30",5,3.23,304.59,,0.001,0.001,155.898,0.059,0.017,0.0304,2623.564,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-10-31",5,3.46,315.08,,0.001,0.001,163.234,0.059,0.017,0.0312,2745.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-01",7,5.23,461.84,,0.001,0.001,240.023,0.059,0.022,0.0253,4038.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-02",5,2.94,246.02,,0.001,0.001,128.122,0.059,0.016,0.033,2154.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-03",4,2.71,189.91,,0.001,0.001,104.736,0.059,0.011,0.0135,1763.356,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-04",6,4.71,355.81,,0.001,0.001,192.311,0.059,0.017,0.0163,3234.267,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-05",12,9.81,752.51,,0.002,0.001,401.379,0.0591,0.035,0.0196,6755.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-06",5,3.96,288.46,,0.001,0.001,156.192,0.059,0.014,0.0122,2628.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-07",4,2.21,188.07,,0,0.001,96.121,0.0593,0.015,0.04,1616.85,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-08",6,4.96,410.57,,0.001,0.001,214.196,0.059,0.02,0.0187,3602.179,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-09",10,7.17,581.66,,0.002,0.001,307.386,0.0591,0.03,0.0245,5172.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-10",10,8.46,698.96,,0.002,0.001,366.396,0.059,0.033,0.021,6166.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-11",6,4.71,322.81,,0.001,0.001,179.467,0.0592,0.018,0.0277,3017.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-12",4,2.46,173.75,,0,0.001,95.132,0.0593,0.011,0.0223,1600.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-13",5,3.21,285.05,,0.001,0.001,147.416,0.059,0.016,0.0312,2480.179,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-14",4,2.46,214.28,,0.001,0.001,110.132,0.0595,0.012,0.0208,1854.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-15",6,4.71,412.99,,0.001,0.001,215.155,0.059,0.022,0.0307,3620.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-17",5,3.48,317.72,,0.001,0.001,164.492,0.059,0.018,0.0312,2767.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-18",7,4,296.96,,0.001,0.001,159.995,0.059,0.018,0.0247,2692.847,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-19",4,2.21,185.63,,0,0.001,97.298,0.0593,0.011,0.0358,1637.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-20",5,3.71,302.61,,0.001,0.001,160.485,0.059,0.017,0.032,2701.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-21",4,2.96,232,,0.001,0.001,124.14,0.0593,0.029,0.0465,2087.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-22",5,4.46,354.1,,0.001,0.001,188.256,0.059,0.015,0.0128,3166.974,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-24",6,4.17,305.93,,0.001,0.001,166.225,0.0592,0.02,0.03,2797.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-25",8,5.67,347.77,,0.001,0.001,198.645,0.059,0.02,0.014,3342.779,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-26",5,3.21,264.6,,0.001,0.001,139.689,0.0592,0.017,0.036,2349.279,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-27",3,1.46,69.15,,0,0.001,42.314,0.059,0.008,0.0267,712.373,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-28",4,2.46,209.82,,0.001,0.001,109.654,0.059,0.015,0.0433,1844.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-29",5,3.96,330.52,,0.001,0.001,174.348,0.059,0.017,0.0336,2934.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-01",7,3.94,235.68,,0.001,0.001,133.142,0.0594,0.018,0.0447,2240.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-02",3,1.46,122.94,,0,0.001,64.794,0.059,0.01,0.048,1090.486,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-03",5,3.71,314.21,,0.001,0.001,165.351,0.0592,0.019,0.0218,2781.019,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-04",8,5.42,356.92,,0.001,0.001,198.674,0.0593,0.022,0.0395,3342.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-05",4,2.71,219.46,,0.001,0.001,116.182,0.0593,0.011,0.0393,1953.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-06",4,2.46,218.34,,0.001,0.001,112.224,0.059,0.014,0.041,1888.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-07",5,3.71,323.28,,0.001,0.001,167.176,0.059,0.016,0.0346,2813.641,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-08",9,5.67,346.85,,0.001,0.001,197.544,0.0591,0.023,0.0372,3325.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-09",4,2.46,175.78,,0,0.001,95.984,0.059,0.017,0.0563,1614.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-10",10,8.19,588.93,,0.002,0.001,318.126,0.059,0.027,0.0103,5355.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-11",6,3.44,201.81,,0.001,0.001,114.78,0.0593,0.013,0.0332,1930.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-12",7,5.71,541.62,,0.001,0.001,270.89,0.0591,0.025,0.0249,4559.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-13",11,8.08,729.59,,0.002,0.001,373.309,0.059,0.031,0.0196,6282.579,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-14",6,4.42,334.94,,0.001,0.001,179.638,0.059,0.02,0.0167,3022.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-15",9,7.42,612.77,,0.002,0.001,321.465,0.059,0.029,0.0231,5410.103,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-16",12,9.94,847.03,,0.002,0.001,434.927,0.059,0.038,0.0209,7317.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-17",4,2.21,185.63,,0,0.001,96.732,0.059,0.01,0.0355,1628.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-18",4,2.46,213.48,,0.001,0.001,111.126,0.059,0.014,0.0378,1869.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-19",6,4.98,361.83,,0.001,0.001,198.224,0.0592,0.018,0.0108,3332.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-20",8,5.19,418.36,,0.001,0.001,220.811,0.0593,0.022,0.0291,3716.416,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-21",3,1.46,107.68,,0,0.001,58.168,0.059,0.009,0.048,979.918,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-22",4,2.7,214.56,,0.001,0.001,113.498,0.059,0.014,0.0418,1911.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-23",4,2.71,199.36,,0.001,0.001,107.663,0.059,0.012,0.037,1812.059,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-24",5,3.21,240.47,,0.001,0.001,127.463,0.059,0.012,0.0318,2145.276,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-25",4,2.21,190.42,,0.001,0.001,99.195,0.0595,0.012,0.0385,1668.78,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-26",8,5.21,451.58,,0.001,0.001,232.851,0.059,0.024,0.0245,3917.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-27",4,3.21,199.98,,0.001,0.001,112.813,0.0593,0.013,0.0203,1897.695,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-29",3,1.46,105.14,,0,0.001,55.738,0.0593,0.011,0.0487,937.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT3",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-06",5,4.21,327.99,,0.001,0.001,177.174,0.059,0.016,0.0118,2981.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-10",4,2.96,230.28,,0.001,0.001,122.652,0.0593,0.011,0.0128,2063.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-15",4,2.96,228.58,,0.001,0.001,122.434,0.0593,0.012,0.0133,2059.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-25",8,6.46,358.97,,0.001,0.001,210.543,0.0591,0.02,0.0149,3543.417,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-03",5,3.96,312.54,,0.001,0.001,167.575,0.0592,0.016,0.013,2818.758,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-04",6,4.96,421.11,,0.001,0.001,220.886,0.0592,0.019,0.0118,3716.156,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-05",6,4.96,406.07,,0.001,0.001,215.517,0.0592,0.018,0.0113,3626.583,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-06",10,6.48,583.34,,0.002,0.001,303.318,0.059,0.029,0.0314,5103.874,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-11",5,4.2,325.06,,0.001,0.001,175.044,0.059,0.019,0.014,2945.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-12",5,4.21,346.58,,0.001,0.001,183.598,0.0592,0.015,0.0114,3088.201,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-17",5,4.21,343.37,,0.001,0.001,182.487,0.059,0.015,0.0112,3071.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-19",5,3.96,316.41,,0.001,0.001,168.313,0.0592,0.015,0.0118,2831.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-26",8,7.83,679.16,,0.002,0.001,355.547,0.059,0.027,0.0105,5982.017,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-27",6,4.09,305.36,,0.001,0.001,165.987,0.0592,0.015,0.0112,2792.511,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-28",6,4.96,382.28,,0.001,0.001,207.393,0.0592,0.018,0.0113,3489.967,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-04",3,2.21,117.14,,0,0.001,70.433,0.059,0.009,0.0143,1185.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-07",1,0.15,0,,0,0.001,1.08,0.06,0.001,0.122,18.15,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-18",2,1.17,54.84,,0,0.001,33.336,0.059,0.008,0.02,560.543,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-19",4,2.8,157.46,,0,0.001,92.011,0.059,0.013,0.0155,1547.953,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-20",5,3.98,290.43,,0.001,0.001,159.195,0.059,0.015,0.0118,2678.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-27",4,2.23,104.24,,0,0.001,63.75,0.0598,0.013,0.042,1071.11,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-28",4,2.98,220.96,,0.001,0.001,119.977,0.0593,0.015,0.014,2018.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-30",3,1.73,82.91,,0,0.001,50.743,0.0593,0.01,0.034,853.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-01",4,2.73,240.74,,0.001,0.001,124.885,0.059,0.016,0.037,2101.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-02",2,1.48,123.76,,0,0.001,64.48,0.059,0.014,0.029,1085.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-03",2,1.46,110.56,,0,0.001,58.552,0.059,0.012,0.022,986.103,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-04",3,1.98,174.72,,0,0.001,90.648,0.0593,0.015,0.051,1525.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-05",10,8.98,806.97,,0.002,0.001,415.885,0.059,0.034,0.0149,6995.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-07",4,2.73,187.88,,0.001,0.001,102.709,0.0593,0.016,0.0388,1727.848,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-08",4,2.98,189.16,,0.001,0.001,106.378,0.059,0.017,0.015,1788.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-09",6,5.18,427.48,,0.001,0.001,224.07,0.059,0.03,0.0188,3772.074,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-13",4,2.98,188.84,,0.001,0.001,106.233,0.059,0.014,0.0153,1788.703,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-14",5,4.2,360.9,,0.001,0.001,187.81,0.059,0.02,0.0134,3159.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-15",3,2,124,,0,0.001,70.785,0.059,0.011,0.0173,1191.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-16",3,2.23,191.17,,0.001,0.001,99.662,0.059,0.015,0.0173,1678.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-22",2,1.48,119.96,,0,0.001,63.108,0.059,0.014,0.0305,1062.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-23",3,2.21,159.37,,0,0.001,87.37,0.059,0.01,0.0143,1471.302,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-24",3,2.73,187.4,,0.001,0.001,104.04,0.059,0.011,0.015,1750.449,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-25",2,1.75,122.95,,0,0.001,67.995,0.059,0.011,0.021,1144.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-29",3,1.48,107.46,,0,0.001,58.866,0.0593,0.016,0.0487,989.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-04",4,3.23,236.74,,0.001,0.001,128.266,0.059,0.014,0.014,2157.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-05",4,3.75,274.9,,0.001,0.001,148.74,0.059,0.016,0.0143,2504.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-06",3,1.98,126.58,,0,0.001,71.003,0.059,0.009,0.0143,1195.454,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-07",3,1.48,99.28,,0,0.001,54.864,0.059,0.01,0.0463,923.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-08",3,1.73,146.48,,0,0.001,76.03,0.059,0.021,0.0387,1280.102,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-22",3,1.48,116.66,,0,0.001,62.122,0.059,0.013,0.0487,1045.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-25",5,3.48,313.2,,0.001,0.001,163.604,0.0592,0.02,0.0316,2753.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-26",6,4.01,295.11,,0.001,0.001,161.632,0.0592,0.019,0.0312,2719.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-27",3,2.23,184.52,,0,0.001,97.417,0.059,0.014,0.02,1640.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-28",4,2.23,187.61,,0.001,0.001,99.353,0.0593,0.017,0.039,1671.085,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-29",4,2.73,152.24,,0,0.001,90.42,0.0595,0.01,0.0208,1521.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-05-31",7,6.6,456.8,,0.001,0.001,255.72,0.0591,0.023,0.0129,4302.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-01",5,2.84,197.28,,0.001,0.001,108.143,0.059,0.015,0.0146,1819.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-02",6,4.5,373.6,,0.001,0.001,198.78,0.059,0.018,0.0272,3346.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-03",4,2.98,255.28,,0.001,0.001,134.972,0.059,0.015,0.0153,2272.254,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-04",3,2.23,116.66,,0,0.001,70.553,0.059,0.009,0.017,1187.789,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-08",6,4.23,348.54,,0.001,0.001,184.779,0.0592,0.018,0.0307,3110.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-09",4,2.73,245.92,,0.001,0.001,127.122,0.059,0.015,0.0225,2138.657,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-10",7,5.75,441.6,,0.001,0.001,239.305,0.059,0.021,0.0153,4025.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-11",3,1.98,167.79,,0,0.001,88.555,0.0593,0.011,0.0257,1489.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-18",13,11.23,937.41,,0.003,0.001,495.334,0.0591,0.042,0.0174,8337.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-22",3,1.48,110.4,,0,0.001,59.494,0.059,0.01,0.0467,1000.972,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-23",3,2.48,220.16,,0.001,0.001,115.128,0.059,0.014,0.0173,1938.796,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-24",4,2.5,174.9,,0,0.001,96.85,0.0593,0.013,0.039,1630.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-25",3,1.48,95.84,,0,0.001,53.796,0.059,0.008,0.045,904.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-26",4,3,269.4,,0.001,0.001,140,0.059,0.015,0.0148,2356.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-27",6,5.6,406,,0.001,0.001,223.1,0.059,0.02,0.0123,3755.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-28",5,2.86,238.29,,0.001,0.001,125.689,0.0594,0.015,0.013,2115.043,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-03",8,7.1,485.6,,0.001,0.001,273.04,0.0593,0.022,0.0224,4594,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-04",4,1.88,110.86,,0,0.001,64.107,0.0593,0.01,0.0143,1078.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-05",6,5.73,512.59,,0.001,0.001,269.217,0.059,0.023,0.0108,4530.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-06",8,7.35,588.9,,0.002,0.001,317.43,0.0591,0.026,0.0143,5339.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-07",8,6.73,517.51,,0.001,0.001,282.051,0.059,0.025,0.0111,4748.431,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-08",5,2.59,216.22,,0.001,0.001,115.325,0.0592,0.013,0.019,1941.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-09",7,5.48,477.04,,0.001,0.001,253.568,0.059,0.021,0.0243,4267.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-10",7,6.33,597.59,,0.002,0.001,310.73,0.059,0.028,0.016,5229.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-11",8,7,627.2,,0.002,0.001,327.92,0.059,0.026,0.0219,5516.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-12",7,6.25,554.75,,0.001,0.001,291.29,0.059,0.025,0.0117,4902.025,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-14",4,2.23,181.51,,0,0.001,96.9,0.059,0.013,0.0383,1630.814,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-15",4,2.73,236.75,,0.001,0.001,124.606,0.059,0.023,0.0348,2095.217,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-16",5,2.96,232.52,,0.001,0.001,125.308,0.059,0.022,0.038,2109.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-17",5,3.48,300.12,,0.001,0.001,158.444,0.0592,0.018,0.0326,2666.154,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-18",5,3.5,308.6,,0.001,0.001,162.01,0.059,0.017,0.0328,2726.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-19",4,2.23,173.51,,0,0.001,93.377,0.0593,0.013,0.0395,1572.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-21",5,3.23,290.61,,0.001,0.001,151.424,0.0592,0.016,0.0308,2548.469,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-22",5,3.21,218.7,,0.001,0.001,122.405,0.0592,0.013,0.0326,2060.191,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-23",3,1.5,112.2,,0,0.001,60.89,0.0593,0.011,0.048,1023.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-24",4,2.48,214.74,,0.001,0.001,113.34,0.059,0.015,0.0375,1906.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-25",8,7.1,547.7,,0.002,0.001,297.62,0.0591,0.025,0.0223,5007.96,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-26",9,7.21,550.12,,0.002,0.001,300.187,0.0591,0.027,0.0219,5049.292,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-27",5,3.61,308.55,,0.001,0.001,163.608,0.059,0.016,0.013,2751.565,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-28",5,3.73,318.22,,0.001,0.001,168.149,0.059,0.016,0.0316,2827.604,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-29",4,3.25,271.25,,0.001,0.001,144.61,0.0593,0.016,0.022,2433.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-30",6,5.87,545.47,,0.001,0.001,283.702,0.059,0.024,0.0102,4774.195,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-07-31",9,7.73,714.66,,0.002,0.001,374.184,0.0591,0.03,0.02,6296.872,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-05",4,2.48,219.02,,0.001,0.001,115.52,0.059,0.014,0.0383,1943.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-06",4,2.25,187.7,,0.001,0.001,100.06,0.0593,0.013,0.0393,1683.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-07",8,7.1,502.7,,0.001,0.001,281.32,0.059,0.024,0.0225,4733.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-08",6,3.63,320.91,,0.001,0.001,168.227,0.0592,0.017,0.0273,2831.101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-09",4,2.73,237.74,,0.001,0.001,124.661,0.059,0.014,0.0388,2097.232,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-10",2,1.48,123.16,,0,0.001,65.128,0.059,0.011,0.023,1095.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-11",3,1.5,101.1,,0,0.001,56.33,0.0593,0.01,0.051,948.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-12",9,8,566.65,,0.002,0.001,314.885,0.0592,0.026,0.0098,5297,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-13",8,6.21,467.2,,0.001,0.001,255.753,0.0591,0.021,0.0238,4303.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-14",10,8.5,733.1,,0.002,0.001,387.15,0.059,0.029,0.0195,6516.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-15",6,4.75,288.4,,0.001,0.0008,166.765,0.0592,0.017,0.0108,2805.537,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-17",13,11.25,852.15,,0.002,0.001,465.965,0.059,0.034,0.0158,7842.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-18",10,9.01,846.55,,0.002,0.001,440.214,0.0591,0.035,0.0093,7407.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-20",10,8.23,683.04,,0.002,0.001,363.569,0.059,0.028,0.0185,6116.823,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-21",8,6.23,528.68,,0.001,0.001,280.778,0.0591,0.022,0.0205,4727.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-22",6,5.23,431.8,,0.001,0.001,231.463,0.059,0.021,0.0108,3895.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-23",4,3.48,323.52,,0.001,0.001,169.744,0.059,0.018,0.0153,2856.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-24",8,6.73,639.21,,0.002,0.001,332.752,0.059,0.028,0.0218,5601.016,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-25",6,4.73,395.94,,0.001,0.001,211.514,0.059,0.018,0.0277,3559.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-26",3,2,145.75,,0,0.001,79.865,0.059,0.011,0.0253,1344.525,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-27",8,6.98,660.8,,0.002,0.001,342.854,0.0591,0.029,0.0223,5767.038,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-28",6,4.69,348.53,,0.001,0.001,191.808,0.059,0.018,0.0123,3227.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-01",3,1.48,124.82,,0,0.001,65.902,0.059,0.011,0.0477,1109.03,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-02",3,1.48,117.84,,0,0.001,63.828,0.059,0.011,0.0467,1074.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-03",5,3.48,277.26,,0.001,0.001,151.192,0.0592,0.016,0.0312,2542.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-04",7,6.48,571,,0.002,0.001,304.498,0.059,0.028,0.0111,5123.361,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-05",12,11.1,798.6,,0.002,0.001,443.5,0.0592,0.033,0.0165,7461.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-06",3,0.74,16.94,,0,0.001,13.434,0.059,0.005,0.0363,225.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-10",6,4.25,378.55,,0.001,0.001,197.935,0.0592,0.02,0.0237,3330.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-11",6,4.23,372.51,,0.001,0.001,195.903,0.059,0.019,0.0285,3295.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-12",5,3.46,309.78,,0.001,0.001,162.002,0.059,0.017,0.0308,2726.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-13",6,4.48,403.82,,0.001,0.001,210.234,0.059,0.022,0.0265,3539.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-14",4,2.78,216.34,,0.001,0.001,116.144,0.059,0.014,0.0335,1953.584,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-15",6,4.21,378.88,,0.001,0.001,198.512,0.0592,0.018,0.0243,3340.931,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-16",7,5.23,465.51,,0.001,0.001,243.474,0.059,0.022,0.0227,4096.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-17",7,5.98,524.66,,0.001,0.001,276.526,0.059,0.026,0.0124,4654.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-18",12,11.08,914.84,,0.002,0.001,489.916,0.059,0.038,0.0158,8245.5,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-19",12,9.38,678.81,,0.002,0.001,375.496,0.0592,0.031,0.0157,6317.035,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-20",9,8.1,636.7,,0.002,0.001,344.03,0.059,0.029,0.0192,5788.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-21",7,4.36,388.49,,0.001,0.001,203.165,0.0591,0.02,0.022,3416.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-22",7,6.23,428.24,,0.001,0.001,239.529,0.0591,0.02,0.01,4029.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-23",5,3.48,308.34,,0.001,0.001,161.514,0.059,0.017,0.0316,2717.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-24",4,2.23,187.61,,0.001,0.001,99.198,0.059,0.013,0.0365,1667.869,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-25",5,3.48,315.3,,0.001,0.001,165.878,0.059,0.017,0.0306,2790.566,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-26",5,3.23,283.51,,0.001,0.001,148.868,0.0592,0.017,0.0302,2504.803,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-27",5,3.23,272.58,,0.001,0.001,145.839,0.0592,0.016,0.0296,2453.868,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-28",5,3.46,278.74,,0.001,0.001,149.732,0.059,0.018,0.0156,2520.054,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-29",4,2.25,172.5,,0,0.001,93.645,0.059,0.011,0.031,1576.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-09-30",8,7.6,407.4,,0.001,0.001,248.7,0.0593,0.02,0.0109,4183,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-01",1,0.13,0.78,,0,0.001,1.365,0.059,0,0.006,22.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-02",5,3.48,222.81,,0.001,0.001,127.935,0.0592,0.015,0.0188,2152.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-03",5,4.73,446.42,,0.001,0.001,232.51,0.059,0.023,0.0122,3913.333,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-04",8,6.23,564.38,,0.002,0.001,298.671,0.059,0.025,0.0209,5024.646,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-05",6,5.23,461.21,,0.001,0.001,243.694,0.059,0.022,0.0107,4101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-06",8,6.21,558.07,,0.001,0.001,291.969,0.0593,0.024,0.0194,4912.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-07",5,3.21,271.2,,0.001,0.001,143.6,0.059,0.015,0.0276,2415.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-08",7,5.23,438.24,,0.001,0.001,234.802,0.059,0.022,0.0233,3950.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-09",6,4.23,377.51,,0.001,0.001,199.284,0.059,0.02,0.0257,3353.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-10",1,0.03,0,,0,0.001,0.192,0.059,0,0.043,3.249,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-11",6,4.25,375.65,,0.001,0.001,199.335,0.0592,0.02,0.0282,3354.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-12",6,4.48,333.98,,0.001,0.001,182.44,0.059,0.017,0.0243,3069.43,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-13",8,6.25,447.6,,0.001,0.001,250.01,0.0591,0.02,0.0194,4208.2,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-14",6,4.73,417.91,,0.001,0.001,222.229,0.0592,0.02,0.024,3741.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-15",5,4.48,353.64,,0.001,0.001,194.132,0.059,0.018,0.0132,3266.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-16",2,1.73,96.73,,0,0.001,58.317,0.0595,0.009,0.017,981.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-17",2,1.48,88.06,,0,0.001,52.122,0.0595,0.01,0.022,876.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-18",5,3.48,316.3,,0.001,0.001,166.94,0.059,0.018,0.0306,2809.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-19",8,4.73,335.63,,0.001,0.001,187.828,0.0591,0.021,0.0353,3161.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-20",4,2.98,201.21,,0.001,0.001,114.711,0.0593,0.012,0.0118,1929.534,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-21",14,10.98,719.44,,0.002,0.001,411.24,0.0593,0.034,0.0169,6918.182,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-22",5,3.23,277.61,,0.001,0.001,147.396,0.059,0.016,0.0302,2480.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-23",6,4.23,324.51,,0.001,0.001,178.23,0.0593,0.018,0.0257,2998.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-24",3,2.46,166.11,,0,0.001,94.645,0.059,0.013,0.0147,1594.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-25",8,6.71,548.79,,0.001,0.001,295.155,0.059,0.027,0.0119,4966.507,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-26",5,2.98,223.16,,0.001,0.001,121.988,0.059,0.021,0.0404,2053.666,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-27",6,3.23,227.58,,0.001,0.001,125.908,0.059,0.02,0.0368,2117.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-28",7,5.21,463.71,,0.001,0.001,243.981,0.059,0.031,0.0303,4107.323,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-29",5,3.25,245.2,,0.001,0.001,135.4,0.0592,0.015,0.031,2278.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-30",4,2.25,199.8,,0.001,0.001,105.35,0.059,0.014,0.038,1774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-10-31",5,3.75,342.1,,0.001,0.001,180.35,0.059,0.019,0.014,3036.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-01",5,3.98,351.48,,0.001,0.001,186.08,0.059,0.019,0.0116,3131.741,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-02",3,1.73,82.38,,0,0.001,51.858,0.0597,0.008,0.0173,871.501,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-03",4,2.73,191.71,,0.001,0.001,108.11,0.059,0.011,0.0135,1819.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-04",4,2.96,250.56,,0.001,0.001,133.988,0.059,0.015,0.0368,2254.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-05",7,5.46,470.74,,0.001,0.001,247.452,0.059,0.022,0.0246,4164.474,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-06",4,2.48,165.8,,0,0.001,93.402,0.059,0.01,0.0343,1571.354,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-07",4,2.21,186.28,,0,0.001,96.882,0.059,0.012,0.0385,1630.271,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-08",4,2.48,216.54,,0.001,0.001,113.298,0.059,0.014,0.0375,1905.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-09",7,4.94,380.18,,0.001,0.001,205.894,0.059,0.027,0.028,3465.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-10",11,8.46,592.07,,0.002,0.001,330.713,0.0591,0.03,0.0137,5565.107,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-11",11,9.48,741.58,,0.002,0.001,401.21,0.0591,0.036,0.0195,6752.492,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-12",8,4.98,378.46,,0.001,0.001,206.453,0.059,0.025,0.0293,3474.17,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-13",4,2.46,210.72,,0.001,0.001,111.685,0.059,0.013,0.021,1880.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-14",4,2.23,196.21,,0.001,0.001,101.921,0.0593,0.014,0.0425,1715.951,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-15",5,3.48,297.02,,0.001,0.001,158.014,0.0592,0.019,0.0376,2658.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-17",5,3.48,311.88,,0.001,0.001,164.536,0.0592,0.017,0.0196,2768.199,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-18",4,2.2,168.41,,0,0.001,91.992,0.0593,0.012,0.036,1546.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-19",4,2.23,160.58,,0,0.001,89.281,0.059,0.013,0.0375,1503.078,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-20",5,3.23,268.38,,0.001,0.001,144.049,0.0594,0.016,0.0328,2423.508,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-21",4,2.73,216.52,,0.001,0.001,117.472,0.059,0.015,0.0398,1976.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-22",4,3.02,216.94,,0.001,0.001,120.142,0.059,0.019,0.0305,2022.122,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-24",7,4.48,354.76,,0.001,0.001,192.06,0.0593,0.023,0.0277,3230.708,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-25",5,3.46,226.58,,0.001,0.001,128.654,0.0594,0.019,0.038,2164.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-27",5,3.73,184.58,,0.001,0.001,115.152,0.0594,0.014,0.0158,1936.471,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-28",2,1.48,88.52,,0,0.001,51.212,0.059,0.011,0.0255,861.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-29",5,4.48,283.76,,0.001,0.001,163.044,0.059,0.017,0.0144,2743.888,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-01",6,3.21,225.95,,0.001,0.001,125.891,0.0592,0.022,0.0528,2118.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-04",3,2.48,151.51,,0,0.001,86.955,0.059,0.012,0.0163,1464.153,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-05",4,2.5,174.3,,0,0.001,97.26,0.0595,0.011,0.0378,1635.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-06",4,2.98,255.52,,0.001,0.001,134.644,0.059,0.015,0.0153,2266.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-07",4,2.48,198.56,,0.001,0.001,107.13,0.0593,0.013,0.0428,1802.434,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-08",3,1.48,102.56,,0,0.001,57.098,0.0593,0.01,0.054,960.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-09",8,7.1,453.8,,0.001,0.001,260.37,0.059,0.023,0.0246,4382.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-10",2,1.13,54.91,,0,0.001,34.017,0.059,0.002,0.0075,572.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-12",5,4.48,405.84,,0.001,0.001,209.024,0.059,0.021,0.0132,3516.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-13",10,7.83,631.99,,0.002,0.001,337.723,0.0591,0.031,0.0115,5682.092,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-14",4,2.48,201.34,,0.001,0.001,108.12,0.0593,0.014,0.0393,1820.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-15",10,7.46,544.8,,0.002,0.001,300.589,0.059,0.03,0.0222,5059.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-16",10,8.21,742.18,,0.002,0.001,383.766,0.059,0.038,0.0241,6456.859,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-17",4,2.23,181.71,,0,0.001,97.147,0.0593,0.011,0.0368,1635.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-18",4,2.46,213.18,,0.001,0.001,112.704,0.059,0.015,0.0403,1895.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-19",5,4.21,258.92,,0.001,0.001,151.116,0.0594,0.016,0.0122,2540.665,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-20",10,6.46,454.82,,0.001,0.001,253.414,0.059,0.027,0.0332,4267.117,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-21",3,1.48,107.18,,0,0.001,58.926,0.0593,0.01,0.0513,991.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-22",4,2.7,209.3,,0.001,0.001,113.444,0.059,0.015,0.0433,1908.56,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-23",4,2.48,185.04,,0.001,0.001,101.042,0.0593,0.013,0.0393,1700.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-24",4,2.23,148.38,,0,0.001,82.419,0.0595,0.012,0.0408,1386.931,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-26",4,2.98,257.05,,0.001,0.001,132.943,0.059,0.015,0.0218,2237.424,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT4",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-06",6,5.23,408.9,,0.001,0.001,221.484,0.059,0.019,0.011,3727.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-07",11,9.46,516.42,,0.002,0.001,305.835,0.0592,0.022,0.0112,5145.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-10",4,2.96,229.28,,0.001,0.001,123.031,0.059,0.011,0.0115,2069.712,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-15",5,3.21,292.63,,0.001,0.001,151.369,0.059,0.013,0.0308,2546.429,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-03",7,5.96,459.54,,0.001,0.001,248.588,0.059,0.02,0.0103,4182.759,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-04",12,10.08,737.89,,0.002,0.001,401.453,0.0591,0.033,0.0193,6752.919,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-05",8,6.09,460.98,,0.001,0.001,249.261,0.059,0.017,0.0085,4194.781,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-06",11,7.46,687.22,,0.002,0.001,356.024,0.059,0.031,0.0298,5991.174,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-09",10,8.23,438.81,,0.001,0.001,261.351,0.059,0.021,0.0196,4399.689,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-11",4,3.2,229.52,,0.001,0.001,126.092,0.059,0.012,0.0125,2122.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-24",10,9.08,488.88,,0.001,0.001,293.64,0.0591,0.023,0.0197,4941.008,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-25",10,8.98,595.53,,0.002,0.001,333.31,0.059,0.025,0.0091,5609.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-26",10,8.2,719.91,,0.002,0.001,376.737,0.059,0.029,0.0227,6337.067,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-27",7,5.09,347.62,,0.001,0.001,193.913,0.0591,0.016,0.0097,3263.699,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-28",5,3.96,256.15,,0.001,0.001,145.941,0.0592,0.013,0.0108,2454.738,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-01",7,6.83,443.84,,0.001,0.001,248.134,0.0593,0.019,0.0097,4173.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-02",2,1.13,52.78,,0,0.001,32.2,0.059,0.002,0.007,541.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-03",4,3.21,224.61,,0.001,0.001,123.555,0.059,0.012,0.0123,2078.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-07",1,0.15,0,,0,0.001,1.08,0.06,0.001,0.121,18.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-09",4,3.46,270.64,,0.001,0.001,145.846,0.059,0.013,0.012,2456.137,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-10",5,4.21,316.03,,0.001,0.001,170.668,0.059,0.013,0.01,2871.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-12",14,13.83,998.55,,0.003,0.001,542.55,0.059,0.038,0.0083,9130.776,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-13",21,19.98,1156.73,,0.003,0.001,681.076,0.0591,0.045,0.0077,11458.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-14",20,18.3,1109.21,,0.003,0.001,645.64,0.0592,0.045,0.009,10858.763,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-15",6,4.36,333.04,,0.001,0.001,179.372,0.0592,0.016,0.0108,3019.067,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-20",1,0.17,0,,0,0.001,1.207,0.059,0.001,0.117,20.451,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-28",4,2.96,192.71,,0.001,0.001,107.477,0.0593,0.01,0.0115,1808.513,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-30",5,3.17,182.68,,0.001,0.001,103.646,0.059,0.015,0.0204,1743.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-01",4,2.93,204.85,,0.001,0.001,112.026,0.0593,0.01,0.0115,1884.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-04",5,3.5,303,,0.001,0.001,156.14,0.059,0.015,0.0306,2626.91,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-05",10,8.71,730.45,,0.002,0.001,378.145,0.059,0.027,0.0116,6366.735,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-06",3,2.21,129.7,,0,0.001,73.144,0.059,0.008,0.0127,1230.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-07",9,5.69,391.93,,0.001,0.001,212.434,0.0593,0.022,0.0322,3575.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-08",2,1.71,113.52,,0,0.001,62.337,0.059,0.01,0.0165,1048.44,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-09",12,9.69,764.24,,0.002,0.001,401.826,0.0591,0.035,0.0123,6761.747,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-13",4,2.98,184.87,,0.001,0.001,103.318,0.059,0.01,0.0113,1739.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-14",5,4.22,336.98,,0.001,0.001,176.67,0.059,0.014,0.0108,2973.036,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-15",4,2.21,178.26,,0,0.001,94.287,0.059,0.011,0.038,1587.664,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-16",5,3.96,282.58,,0.001,0.001,153.202,0.0592,0.013,0.0104,2576.921,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-23",7,6.83,467.5,,0.001,0.001,258.683,0.0593,0.019,0.0096,4352.131,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-24",7,5.34,369.22,,0.001,0.001,202.576,0.0591,0.018,0.0096,3410.053,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-25",3,2.73,175.86,,0,0.001,98.777,0.0593,0.01,0.0147,1661.61,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-26",5,3.96,278.45,,0.001,0.001,152.586,0.0592,0.012,0.0098,2568.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-27",4,2.96,191.41,,0.001,0.001,107.549,0.059,0.009,0.0105,1811.098,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-28",5,4.23,284.3,,0.001,0.001,157.654,0.059,0.013,0.0102,2651.906,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-29",5,3.96,289.58,,0.001,0.001,157.66,0.0592,0.013,0.01,2654.899,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-01",5,3.98,326.84,,0.001,0.001,171.519,0.059,0.016,0.0102,2887.638,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-04",7,6.83,457.67,,0.001,0.001,253.951,0.059,0.018,0.0094,4274.949,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-05",7,4.61,373.63,,0.001,0.001,195.202,0.059,0.016,0.026,3285.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-06",6,5.21,351.35,,0.001,0.001,193.333,0.0592,0.015,0.0097,3253.755,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-07",6,3.96,261.68,,0.001,0.001,144.246,0.059,0.014,0.0278,2426.506,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-08",4,2.46,177.84,,0,0.001,95.002,0.059,0.01,0.0365,1597.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-21",6,4.98,268.83,,0.001,0.001,159.13,0.0592,0.014,0.01,2678.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-24",4,2.46,196.04,,0.001,0.001,103.872,0.059,0.011,0.036,1747.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-25",8,6.21,501.31,,0.001,0.001,266.549,0.0591,0.021,0.0223,4486.296,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-26",8,7.08,481.48,,0.001,0.001,267.972,0.059,0.021,0.0226,4509.912,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-27",4,2.59,160.34,,0,0.001,90.559,0.059,0.01,0.0108,1523.968,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-28",5,3.21,272.44,,0.001,0.001,142.196,0.059,0.012,0.0292,2393.379,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-29",5,3.71,294.46,,0.001,0.001,156.53,0.0592,0.012,0.0112,2632.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-30",7,5.96,314.03,,0.001,0.001,188.409,0.0594,0.016,0.0096,3167.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-05-31",7,6.08,419.64,,0.001,0.001,232.52,0.059,0.018,0.0234,3913.784,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-01",6,3.34,211.22,,0.001,0.001,117.711,0.0592,0.011,0.027,1980.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-02",6,4.5,360.7,,0.001,0.001,191.78,0.0592,0.016,0.0267,3227.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-03",6,4.46,354.96,,0.001,0.001,188.81,0.0592,0.015,0.0275,3177.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-04",5,3.46,236.38,,0.001,0.001,130.742,0.0592,0.012,0.0294,2199.328,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-08",7,5.21,401.05,,0.001,0.001,214.937,0.0591,0.018,0.027,3617.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-09",5,3.48,306.12,,0.001,0.001,156.956,0.059,0.015,0.0358,2639.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-10",4,3.23,266.53,,0.001,0.001,140.341,0.059,0.02,0.029,2361.336,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-11",5,3.46,292.52,,0.001,0.001,153.296,0.0594,0.013,0.0302,2578.626,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-14",5,3.21,274.5,,0.001,0.001,144.083,0.059,0.015,0.0314,2424.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-17",4,2.46,180.68,,0,0.001,98.774,0.059,0.011,0.0365,1662.838,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-18",5,3.21,254.36,,0.001,0.001,135.067,0.0592,0.012,0.0296,2272.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-19",21,20.1,1423.8,,0.004,0.001,782.75,0.059,0.059,0.0137,13170.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-20",1,0.13,0.78,,0,0.001,1.378,0.059,0,0.006,23.205,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-22",5,3.48,293.52,,0.001,0.001,153.22,0.059,0.014,0.03,2579.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-23",4,2.46,206.02,,0.001,0.001,108.028,0.059,0.011,0.0353,1818.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-24",5,3.48,264.52,,0.001,0.001,142.408,0.059,0.013,0.0298,2395.652,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-25",4,2.48,129.24,,0,0.001,77.348,0.0593,0.008,0.0358,1303.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-26",8,7.08,496.56,,0.001,0.001,272.372,0.0591,0.02,0.0211,4581.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-27",8,6.21,413.55,,0.001,0.001,230.232,0.0593,0.018,0.0211,3873.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-28",5,2.34,141.8,,0,0.001,80.477,0.0592,0.008,0.029,1353.788,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-03",7,5.21,377.26,,0.001,0.001,207.19,0.0591,0.017,0.0239,3486.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-05",6,4.46,341.2,,0.001,0.001,183.576,0.059,0.017,0.0282,3090.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-06",5,3.46,302.1,,0.001,0.001,157.452,0.059,0.014,0.0322,2650.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-07",8,7.08,489.56,,0.001,0.001,271.396,0.059,0.02,0.0213,4566.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-08",6,3.34,272.43,,0.001,0.001,144.032,0.0592,0.013,0.0257,2421.642,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-09",8,7.08,452.72,,0.001,0.001,256.884,0.059,0.019,0.0213,4324.648,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-10",10,7.36,677.44,,0.002,0.001,350.014,0.0591,0.026,0.0185,5892.516,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-11",7,5.98,519.94,,0.001,0.001,270.652,0.059,0.019,0.0231,4554.42,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-12",7,6.23,553.44,,0.001,0.001,288.164,0.059,0.023,0.0107,4847.764,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-13",3,1.48,68.48,,0,0.001,42.256,0.059,0.006,0.0433,711.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-14",4,2.21,178.6,,0,0.001,94.136,0.059,0.011,0.0358,1584.342,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-15",4,2.21,196.26,,0.001,0.001,101.616,0.0595,0.012,0.0368,1708.921,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-16",5,3.21,274.31,,0.001,0.001,143.891,0.0594,0.014,0.032,2420.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-17",5,3.46,300,,0.001,0.001,155.604,0.059,0.015,0.0304,2618.702,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-18",5,3.21,284.34,,0.001,0.001,147.54,0.059,0.013,0.0304,2482.255,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-19",4,2.21,168.47,,0,0.001,90.231,0.0593,0.01,0.0365,1517.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-20",3,1.48,125.6,,0,0.001,65.156,0.059,0.008,0.0457,1096.226,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-21",5,3.21,267.55,,0.001,0.001,140.534,0.0594,0.013,0.0276,2364.048,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-22",7,6.08,395.72,,0.001,0.001,222.436,0.059,0.018,0.0237,3742.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-23",5,2.34,140.54,,0,0.001,80.06,0.059,0.008,0.029,1348.039,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-24",4,2.21,180.5,,0,0.001,94.762,0.059,0.01,0.0358,1595.544,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-25",8,7.08,555.64,,0.001,0.001,297.028,0.059,0.024,0.0219,4997.772,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-26",10,8.73,690.84,,0.002,0.001,368.416,0.0592,0.028,0.0095,6197.113,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-27",8,6.19,468.03,,0.001,0.001,252.314,0.059,0.021,0.0113,4247.277,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-30",6,5.87,549.42,,0.001,0.001,282.141,0.059,0.022,0.0097,4746.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-07-31",9,7.78,696.33,,0.002,0.001,361.77,0.059,0.027,0.0117,6086.251,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-03",5,3.83,206.76,,0.001,0.001,123.961,0.0594,0.012,0.0116,2084.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-05",4,2.48,220.3,,0.001,0.001,114.426,0.0593,0.012,0.0348,1925.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-06",4,2.25,185.85,,0,0.001,98.155,0.0595,0.011,0.0365,1650.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-07",4,2.46,204.34,,0.001,0.001,107.494,0.059,0.012,0.0378,1809.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-08",5,3.5,312.1,,0.001,0.001,162.11,0.0592,0.015,0.0296,2727.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-09",5,3.46,281.64,,0.001,0.001,148.622,0.059,0.013,0.0308,2498.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-10",5,3.23,272.61,,0.001,0.001,143.061,0.059,0.013,0.0314,2407.679,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-11",5,3.23,286.52,,0.001,0.001,148.233,0.059,0.014,0.0314,2492.789,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-12",8,7.08,498.56,,0.001,0.001,275.196,0.059,0.022,0.023,4630.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-13",9,6.36,503.35,,0.001,0.001,268.838,0.059,0.021,0.0214,4522.933,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-14",10,8.48,735.64,,0.002,0.001,384.632,0.0591,0.028,0.0189,6473.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-15",6,4.74,291.04,,0.001,0.0008,166.196,0.0592,0.015,0.01,2796.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-17",12,10.23,775.27,,0.002,0.001,419.41,0.059,0.03,0.0159,7057.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-18",10,9.01,853.55,,0.002,0.001,438.263,0.059,0.032,0.0087,7373.228,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-19",8,7.33,379.86,,0.001,0.001,228.344,0.059,0.017,0.0121,3842.563,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-20",11,8.34,611.74,,0.002,0.001,331.966,0.0592,0.024,0.0168,5583.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-21",10,7.93,575.58,,0.002,0.001,314.975,0.059,0.027,0.0185,5299.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-22",7,5.36,437.48,,0.001,0.001,232.892,0.0591,0.02,0.0094,3917.681,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-23",4,3.21,297.02,,0.001,0.001,154.603,0.059,0.015,0.013,2601.197,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-24",7,5.96,569.64,,0.001,0.001,293.848,0.059,0.023,0.0227,4944.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-25",6,4.71,392.86,,0.001,0.001,207.692,0.0592,0.017,0.0268,3495.4,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-26",3,1.46,72.88,,0,0.001,44.394,0.0597,0.006,0.0437,747.442,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-27",3,1.96,168.53,,0,0.001,88.178,0.059,0.011,0.0123,1482.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-28",6,4.68,337.92,,0.001,0.001,185.671,0.059,0.017,0.0113,3126.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-02",3,1.46,117.66,,0,0.001,63.05,0.059,0.009,0.0453,1060.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-03",7,5.21,458.39,,0.001,0.001,242.939,0.0593,0.019,0.0224,4087.889,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-04",7,6.21,544.28,,0.001,0.001,287.435,0.059,0.023,0.0096,4836.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-05",8,7.21,642.36,,0.002,0.001,337.757,0.059,0.026,0.0091,5686.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-06",2,0.6,16.14,,0,0.001,12.006,0.06,0.004,0.041,201.621,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-10",6,4.23,381.51,,0.001,0.001,197.414,0.0593,0.017,0.0245,3320.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-11",6,4.21,376.52,,0.001,0.001,195.42,0.0592,0.016,0.0275,3288.866,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-12",6,4.48,411.88,,0.001,0.001,212.316,0.059,0.019,0.0278,3574.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-13",6,4.46,407.18,,0.001,0.001,209.574,0.059,0.018,0.027,3526.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-14",5,3.46,305.48,,0.001,0.001,158.658,0.059,0.014,0.0306,2669.428,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-15",7,5.97,472.23,,0.001,0.001,252.453,0.059,0.019,0.0096,4248.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-16",7,5.21,470.39,,0.001,0.001,242.702,0.059,0.02,0.025,4083.541,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-17",7,5.23,459.05,,0.001,0.001,239.207,0.059,0.02,0.0249,4026.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-18",11,10.08,769.08,,0.002,0.001,415.088,0.059,0.031,0.0189,6985.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-19",11,8.59,652.49,,0.002,0.001,352.621,0.0591,0.028,0.0188,5933.812,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-20",9,8.08,638.64,,0.002,0.001,340.504,0.0591,0.026,0.0207,5730.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-21",6,3.61,318.54,,0.001,0.001,164.439,0.059,0.017,0.0268,2766.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-22",9,7.96,591.18,,0.002,0.001,320.404,0.059,0.024,0.0088,5390.677,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-23",8,6.98,526.12,,0.001,0.001,283.776,0.059,0.023,0.0109,4777.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-24",5,3.46,310.96,,0.001,0.001,160.642,0.0592,0.015,0.0316,2702.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-25",5,3.46,316.42,,0.001,0.001,164.494,0.059,0.016,0.0306,2768.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-26",5,3.21,286.47,,0.001,0.001,148.016,0.0594,0.015,0.0298,2489.426,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-27",5,3.23,272.68,,0.001,0.001,144.412,0.0592,0.014,0.0306,2431.069,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-28",6,4.21,378.47,,0.001,0.001,197.637,0.059,0.018,0.027,3326.657,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-29",5,3.48,267.56,,0.001,0.001,144.764,0.0594,0.014,0.0318,2435.984,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-02",7,5.23,329.97,,0.001,0.001,188.046,0.0591,0.014,0.0194,3166.599,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-03",4,3.46,321.96,,0.001,0.001,166.172,0.059,0.017,0.0143,2795.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-04",12,10.21,798.71,,0.002,0.001,432.433,0.059,0.032,0.0163,7278.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-06",3,1.46,121.98,,0,0.001,63.492,0.059,0.011,0.0243,1068.274,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-07",5,3.21,274.2,,0.001,0.001,143.202,0.0592,0.013,0.0308,2409.682,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-08",5,3.46,306.96,,0.001,0.001,160.38,0.059,0.015,0.0312,2699.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-09",6,4.21,378.52,,0.001,0.001,198.052,0.059,0.018,0.0265,3331.864,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-11",6,4.23,372.68,,0.001,0.001,196.175,0.0592,0.018,0.027,3301.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-12",5,3.48,253.92,,0.001,0.001,137.964,0.059,0.012,0.0318,2320.608,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-13",8,6.25,397.3,,0.001,0.001,228.29,0.059,0.016,0.0204,3841.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-14",7,5.21,478.36,,0.001,0.001,249.548,0.059,0.021,0.0236,4199.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-15",5,4.48,344.48,,0.001,0.001,188.198,0.059,0.017,0.0124,3166.902,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-16",4,2.23,157.81,,0,0.001,87.756,0.0595,0.009,0.033,1476.706,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-17",2,1.48,82.78,,0,0.001,49.27,0.059,0.008,0.02,829.204,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-18",7,3.94,326.21,,0.001,0.001,173.809,0.0591,0.02,0.0291,2924.483,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-19",8,4.67,316.1,,0.001,0.001,176.942,0.0593,0.019,0.0359,2977.873,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-20",5,3.21,263.2,,0.001,0.001,141.113,0.059,0.013,0.0304,2373.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-21",5,3.23,282.59,,0.001,0.001,148.729,0.059,0.014,0.0298,2503.176,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-22",5,3.23,281.74,,0.001,0.001,147.39,0.0592,0.014,0.0306,2480.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-23",4,2.46,204.36,,0.001,0.001,108.748,0.059,0.011,0.0365,1829.692,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-24",6,4.21,332.58,,0.001,0.001,180.194,0.0592,0.018,0.0282,3033.412,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-25",6,4.71,391.54,,0.001,0.001,207.977,0.0593,0.018,0.0268,3499.534,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-26",6,3.71,242.26,,0.001,0.001,137.139,0.0593,0.018,0.0333,2307.829,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-27",5,3.48,308.52,,0.001,0.001,162.468,0.0592,0.017,0.035,2733.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-28",8,4.71,418.54,,0.001,0.001,218.499,0.0593,0.023,0.0384,3677.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-29",5,3.23,291.8,,0.001,0.001,151.714,0.0592,0.016,0.032,2554.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-30",4,2.25,201.9,,0.001,0.001,104.505,0.059,0.012,0.0375,1758.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-10-31",5,3.23,289.03,,0.001,0.001,150.466,0.059,0.015,0.0328,2531.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-01",6,4.21,362.63,,0.001,0.001,190.035,0.0592,0.018,0.0288,3196.598,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-02",4,2.21,179.42,,0,0.001,95.296,0.059,0.011,0.0363,1603.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-03",5,3.21,292.39,,0.001,0.001,151.807,0.059,0.014,0.0304,2554.641,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-04",5,3.46,313.1,,0.001,0.001,161.72,0.059,0.015,0.0328,2722.006,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-05",7,5.98,521.34,,0.001,0.001,268.87,0.059,0.02,0.0106,4524.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-06",5,4.21,309.95,,0.001,0.001,168.222,0.059,0.014,0.0114,2829.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-07",4,2.21,185.18,,0,0.001,95.355,0.059,0.012,0.039,1604.658,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-08",4,2.96,255.08,,0.001,0.001,131.35,0.0593,0.013,0.0135,2210.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-09",7,4.42,361.08,,0.001,0.001,189.432,0.0591,0.022,0.0164,3186.667,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-10",9,6.67,486.72,,0.001,0.001,263.41,0.0591,0.026,0.0253,4430.903,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-11",5,3.46,288.86,,0.001,0.001,152.032,0.0592,0.022,0.0486,2557.518,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-12",4,2.21,195.16,,0.001,0.001,100.971,0.059,0.013,0.0398,1698.445,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-13",4,2.21,189.42,,0,0.001,98.667,0.0593,0.011,0.038,1660.453,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-14",4,2.21,201.63,,0.001,0.001,102.432,0.059,0.012,0.037,1724.065,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-15",5,3.46,299.96,,0.001,0.001,156.558,0.059,0.016,0.036,2635.368,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-17",4,2.46,214.57,,0.001,0.001,112.082,0.0593,0.012,0.019,1885.842,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-18",4,2.2,169.48,,0,0.001,91.025,0.059,0.01,0.0353,1530.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-19",4,2.21,163.79,,0,0.001,88.446,0.0595,0.01,0.0365,1487.81,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-20",4,2.23,177.35,,0,0.001,94.89,0.059,0.011,0.0385,1596.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-21",4,2.96,230.2,,0.001,0.001,123.52,0.0593,0.012,0.037,2077.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-22",4,2.71,212.46,,0.001,0.001,113.59,0.0593,0.012,0.0368,1911.877,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-24",3,1.71,137.08,,0,0.001,73.069,0.059,0.009,0.0193,1229.503,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-25",9,6.67,435.49,,0.001,0.001,244.755,0.0591,0.018,0.01,4117.437,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-28",4,2.46,217.34,,0.001,0.001,112.546,0.059,0.015,0.0443,1893.452,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-29",4,2.48,200.12,,0.001,0.001,106.372,0.059,0.013,0.0415,1789.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-01",8,5.94,365.29,,0.001,0.001,209.899,0.0591,0.023,0.0149,3530.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-02",6,4.46,262.64,,0.001,0.001,153.633,0.0592,0.016,0.0157,2584.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-03",7,6.08,344.64,,0.001,0.001,202.428,0.0591,0.017,0.0271,3406.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-04",7,5.11,267.39,,0.001,0.001,158.682,0.059,0.014,0.0093,2669.605,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-05",4,2.48,193.96,,0.001,0.001,103.54,0.059,0.011,0.0383,1741.724,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-07",4,2.46,201.88,,0.001,0.001,106.21,0.059,0.012,0.041,1787.278,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-08",5,2.94,188,,0.001,0.001,105.556,0.0592,0.014,0.0382,1775.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-09",4,2.46,167.48,,0,0.001,92.772,0.0595,0.018,0.0605,1559.846,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-10",5,3.42,254.88,,0.001,0.001,135.708,0.059,0.017,0.0168,2284.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-11",7,4.92,311.82,,0.001,0.001,176.214,0.059,0.019,0.0277,2964.768,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-12",5,3.48,316.36,,0.001,0.001,160.756,0.059,0.017,0.0322,2706.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-13",10,7.83,657.78,,0.002,0.001,342.388,0.0592,0.03,0.0108,5761.181,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-14",4,2.96,227.96,,0.001,0.001,122.043,0.0593,0.012,0.019,2054.351,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-15",9,5.92,449.78,,0.001,0.001,241.522,0.059,0.023,0.0356,4063.996,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-16",9,6.94,552.53,,0.001,0.001,290.459,0.0591,0.028,0.024,4887.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-18",4,2.71,228.08,,0.001,0.001,119.623,0.059,0.012,0.0188,2013.735,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-19",5,3.71,267.29,,0.001,0.001,146.906,0.059,0.015,0.0348,2472.694,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-20",4,2.21,184.26,,0,0.001,96.726,0.0595,0.012,0.0403,1627.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-23",7,6.83,358.67,,0.001,0.001,216.1,0.059,0.017,0.01,3636.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-24",6,3.36,203.26,,0.001,0.001,114.974,0.0592,0.012,0.0282,1934.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-25",4,2.21,189.5,,0,0.001,98.483,0.0593,0.012,0.0385,1657.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-26",4,2.23,186.2,,0,0.001,97.15,0.059,0.01,0.0358,1635.769,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Walnut Creek Energy Park",57515,"GT5",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-02",4,2.47,174.1,,0,0.001,97.548,0.059,0.013,0.0183,1642.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-03",9,7.74,816.36,,0.002,0.001,420.522,0.059,0.028,0.0112,7076.806,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-14",2,1.22,57.67,,0,0.001,36.407,0.059,0.007,0.0215,612.322,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-17",4,2.47,117.59,,0,0.001,74.213,0.0593,0.01,0.017,1247.505,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-25",3,1.72,88.97,,0,0.001,54.771,0.059,0.007,0.0137,922.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-03",2,1.22,59.9,,0,0.001,37.386,0.0595,0.007,0.017,628.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-05",4,2.48,188.49,,0.001,0.001,101.17,0.059,0.02,0.0203,1702.373,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-07",3,1.23,57.42,,0,0.001,35.522,0.0597,0.005,0.047,597.549,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-16",1,0.82,60.68,,0,0.001,33.866,0.059,0.007,0.024,569.982,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-17",2,1.15,56.2,,0,0.001,35.44,0.059,0.002,0.007,596.595,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-24",2,1.22,57.1,,0,0.001,36.342,0.059,0.005,0.018,611.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-25",8,5.96,496.27,,0.001,0.001,270.623,0.059,0.024,0.0134,4552.486,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-26",2,1.22,58.24,,0,0.001,36.724,0.059,0.008,0.02,617.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-01",3,1.97,117.68,,0,0.001,68.73,0.059,0.009,0.0147,1156.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-02",2,1.23,61.77,,0,0.001,37.878,0.059,0.006,0.029,637.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-14",3,1.99,191.24,,0.001,0.001,100.47,0.059,0.01,0.0137,1690.932,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-21",2,1.22,58.32,,0,0.001,36.781,0.059,0.006,0.021,618.851,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-23",4,2.48,148,,0,0.001,87.36,0.059,0.009,0.0383,1470.256,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-24",3,1.23,91.55,,0,0.001,50.163,0.059,0.008,0.0503,843.407,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-26",5,3.23,282.49,,0.001,0.001,150.908,0.0592,0.015,0.0344,2539.859,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-28",3,2.25,226.79,,0.001,0.001,117.826,0.059,0.014,0.0257,1983.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-29",2,1.24,89.7,,0,0.001,49.806,0.059,0.007,0.0145,838.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-05",2,1.23,64.54,,0,0.001,39.383,0.059,0.006,0.02,663.115,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-06",3,1.22,58.39,,0,0.001,36.323,0.059,0.006,0.0507,611.371,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-20",2,1.22,58.26,,0,0.001,36.57,0.0595,0.006,0.0165,615.752,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-21",3,1.25,109.34,,0,0.001,57.818,0.059,0.008,0.0477,973.532,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-23",1,0.02,0,,0,0.001,0.16,0.06,0,0.021,2.684,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-24",5,2.96,210.21,,0.001,0.001,118.038,0.059,0.014,0.0134,1985.009,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-25",2,1.18,61.41,,0,0.001,38.139,0.059,0.006,0.0265,641.972,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-29",5,2.52,161.08,,0,0.0008,93.544,0.0594,0.009,0.033,1573.704,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-01",6,2.96,137.2,,0,0.001,86.043,0.059,0.012,0.0388,1447.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-04",3,1.8,173.11,,0,0.001,91.035,0.059,0.01,0.0203,1531.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-05",10,7.96,761.28,,0.002,0.001,401.903,0.059,0.032,0.0196,6761.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-07",5,2.67,129.58,,0,0.001,81.406,0.059,0.012,0.034,1370.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-09",3,1.73,160.97,,0,0.001,84.63,0.059,0.009,0.0197,1423.384,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-11",4,2.73,268.52,,0.001,0.001,138.98,0.059,0.013,0.0118,2339.495,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-16",3,1.71,109.05,,0,0.001,63.033,0.0593,0.008,0.0127,1061.792,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-21",3,2.23,160.32,,0,0.001,90.013,0.059,0.009,0.0147,1515.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-26",4,2.46,212.03,,0.001,0.001,114.268,0.059,0.011,0.0153,1922.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-27",3,1.71,128.89,,0,0.001,71.998,0.059,0.008,0.0127,1211.815,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-29",7,5.25,287.5,,0.001,0.001,176.375,0.0593,0.014,0.0214,2967.193,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-15",4,2.44,117.09,,0,0.001,74.514,0.0593,0.006,0.0093,1253.091,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-26",5,3.46,216.57,,0.001,0.001,126.804,0.059,0.011,0.0146,2134.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-27",2,1.25,110.1,,0,0.001,58.54,0.059,0.008,0.027,985,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-03",2,1.23,87.63,,0,0.001,49.098,0.059,0.006,0.0245,826.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-04",2,1.23,105.99,,0,0.001,56.882,0.059,0.007,0.0125,957.213,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-05",2,1.71,118.65,,0,0.001,67.613,0.059,0.008,0.013,1137.375,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-06",3,1.48,131.57,,0,0.001,70.334,0.0593,0.008,0.0173,1184.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-07",2,1.48,130.6,,0,0.001,69.711,0.059,0.008,0.0135,1173.157,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-09",2,1.23,100.74,,0,0.001,54.867,0.059,0.007,0.025,923.148,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-10",4,2.98,219.7,,0.001,0.001,123.189,0.059,0.01,0.016,2073.929,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-11",5,3.98,310.93,,0.001,0.001,170.936,0.0594,0.015,0.0158,2876.785,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-12",5,3.23,299.45,,0.001,0.001,158.593,0.0594,0.013,0.03,2667.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-17",3,1.23,104.48,,0,0.001,56.342,0.059,0.008,0.044,948.876,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-18",2,1.21,57.6,,0,0.001,36.461,0.059,0.005,0.013,613.669,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-25",3,1.46,75.31,,0,0.001,46.772,0.0593,0.007,0.0197,787.087,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-26",3,2.25,219.45,,0.001,0.001,115.055,0.059,0.012,0.014,1935.97,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-27",5,3.21,200.07,,0.001,0.001,116.995,0.0592,0.011,0.0284,1969.491,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-28",3,1.21,56.28,,0,0.001,35.794,0.059,0.005,0.0437,602.545,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-29",4,2.46,127.66,,0,0.001,79.384,0.0593,0.008,0.0345,1335.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-30",4,2.96,216.54,,0.001,0.001,121.856,0.059,0.011,0.0123,2050.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-07-31",4,2.71,227.53,,0.001,0.001,123.055,0.059,0.011,0.0343,2071.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-01",5,3.23,209.32,,0.001,0.001,122.358,0.0592,0.011,0.0284,2058.509,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-02",4,2.21,114.2,,0,0.001,71.688,0.0595,0.007,0.033,1206.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-03",4,2.23,107.45,,0,0.001,68.617,0.0595,0.007,0.0333,1154.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-04",3,1.2,54.25,,0,0.001,35.36,0.0597,0.005,0.0417,595.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-09",2,1.21,57.98,,0,0.001,37.092,0.059,0.006,0.02,624.103,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-10",3,1.46,74.12,,0,0.001,46.317,0.059,0.006,0.018,779.379,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-11",3,1.21,55.41,,0,0.001,35.746,0.0593,0.005,0.042,600.899,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-12",4,2.71,146.82,,0,0.001,89.937,0.0595,0.009,0.0158,1513.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-13",5,3.73,249.39,,0.001,0.001,142.991,0.059,0.014,0.0132,2406.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-14",8,7.05,512.15,,0.001,0.001,287.79,0.0593,0.021,0.0089,4841.385,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-15",7,5.96,419.18,,0.001,0.001,238.494,0.059,0.017,0.0096,4014.828,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-16",6,4.21,281.36,,0.001,0.001,162.547,0.0593,0.012,0.0235,2734.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-17",9,7.46,448.24,,0.001,0.001,262.102,0.0592,0.018,0.0109,4410.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-18",11,9.21,666.33,,0.002,0.001,361.498,0.0591,0.025,0.0166,6083.309,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-19",9,7.96,524.15,,0.001,0.001,296.566,0.059,0.021,0.0084,4988.333,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-20",6,4.98,473.84,,0.001,0.001,250.29,0.059,0.018,0.0083,4211.486,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-21",4,2.21,107.62,,0,0.001,68.485,0.059,0.007,0.0343,1152.021,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-22",4,2.23,142.96,,0,0.001,83.019,0.0593,0.01,0.0338,1397.427,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-23",3,1.23,57.79,,0,0.001,37.004,0.059,0.005,0.0407,622.603,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-24",4,2.73,143.43,,0,0.001,88.863,0.059,0.008,0.0163,1495.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-25",6,4.21,257.91,,0.001,0.001,152.751,0.0592,0.013,0.0247,2573.028,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-26",4,2.23,107.99,,0,0.001,68.709,0.059,0.007,0.033,1156.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-27",8,4.75,272.82,,0.001,0.001,164.552,0.0593,0.015,0.0229,2770.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-28",5,3.75,207.55,,0.001,0.001,126.25,0.0594,0.011,0.0104,2122.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-29",4,2.23,108.81,,0,0.001,68.923,0.0593,0.007,0.034,1159.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-08-31",3,1.21,55.12,,0,0.001,35.659,0.059,0.006,0.0447,599.778,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-03",2,1.24,73.88,,0,0.001,43.762,0.059,0.007,0.0235,737.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-04",5,3.22,211.5,,0.001,0.001,122.654,0.0592,0.011,0.0278,2064.076,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-05",11,10.85,778.35,,0.002,0.001,440.74,0.0591,0.03,0.0082,7414.955,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-06",16,12.83,893.19,,0.003,0.001,510.196,0.0591,0.037,0.0104,8585.711,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-07",6,4.24,214.36,,0.001,0.001,134.656,0.0593,0.011,0.0238,2264.268,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-08",8,4.47,268.26,,0.001,0.001,158.602,0.059,0.016,0.0321,2669.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-09",4,2.27,179.4,,0,0.001,97.808,0.059,0.009,0.0303,1644.622,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-10",4,2.22,110.82,,0,0.001,69.384,0.059,0.007,0.0333,1167.65,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-11",6,3.58,216.36,,0.001,0.001,126.634,0.059,0.016,0.0275,2132.079,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-12",4,2.22,109.7,,0,0.001,68.87,0.0593,0.007,0.0325,1159.002,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-13",3,1.22,55.5,,0,0.001,35.708,0.0593,0.005,0.0417,601.486,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-15",3,1.24,54.88,,0,0.001,35.632,0.059,0.005,0.0407,600.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-16",3,1.22,54.62,,0,0.001,35.548,0.0597,0.006,0.043,598.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-19",4,2.75,229.66,,0.001,0.001,123.807,0.059,0.011,0.0333,2083.928,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-20",4,2.23,134.76,,0,0.001,79.362,0.059,0.008,0.032,1334.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-21",4,2.26,163.77,,0,0.001,90.818,0.0593,0.008,0.0315,1529.056,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-22",3,1.49,67.91,,0,0.001,43.349,0.0593,0.006,0.0173,729.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-23",3,1.23,54.96,,0,0.001,35.277,0.0593,0.006,0.0427,594.211,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-24",5,2.45,111.15,,0,0.001,71.564,0.0594,0.009,0.0366,1204.317,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-25",1,0.02,0,,0,0.001,0.172,0.059,0,0.091,2.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-28",5,3.47,174.22,,0.001,0.001,108.949,0.0592,0.009,0.0132,1833.248,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-29",11,6.86,488.93,,0.001,0.001,274.877,0.0593,0.024,0.0323,4624.208,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-09-30",9,5.61,414.23,,0.001,0.001,231,0.0591,0.019,0.0293,3887.147,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-01",6,4.24,213.76,,0.001,0.001,133.06,0.0592,0.011,0.026,2238.172,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-02",3,2.49,227.81,,0.001,0.001,120.459,0.059,0.011,0.0133,2027.111,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-03",3,1.24,54.76,,0,0.001,35.36,0.0593,0.006,0.051,595.432,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-04",4,2.25,124.77,,0,0.001,74.587,0.059,0.009,0.0353,1255.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-05",6,4.75,258.81,,0.001,0.001,158.367,0.0593,0.013,0.0097,2663.924,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-06",4,2.24,108.48,,0,0.001,68.704,0.059,0.007,0.0333,1157.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-07",7,4.51,279.95,,0.001,0.001,163.792,0.0591,0.015,0.0274,2755.807,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-12",6,4.22,215.7,,0.001,0.001,135.578,0.0592,0.012,0.0245,2281.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-13",7,4.95,269.48,,0.001,0.001,165.127,0.059,0.016,0.0101,2777.944,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-14",9,6.45,403.07,,0.001,0.001,236.951,0.0592,0.019,0.0237,3988.448,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-16",3,1.23,56.03,,0,0.001,36.027,0.0593,0.006,0.0433,606.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-17",4,2.23,109.86,,0,0.001,69.549,0.0595,0.007,0.0328,1170.953,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-18",6,3.22,242.14,,0.001,0.001,134.63,0.0592,0.015,0.0133,2263.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-19",4,2.22,147.6,,0,0.001,84.594,0.059,0.009,0.0333,1424.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-21",4,2.22,116.7,,0,0.001,71.968,0.059,0.008,0.0335,1211.83,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-22",6,3.73,321.2,,0.001,0.001,172.428,0.059,0.018,0.0115,2901.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-25",2,1.12,53.34,,0,0.001,33.712,0.059,0.006,0.0275,567.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-26",2,1.22,66.5,,0,0.001,40.478,0.06,0.006,0.014,680.23,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-01",3,1.49,74.77,,0,0.001,46.739,0.0597,0.007,0.0197,786.502,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-02",3,1.24,58.24,,0,0.001,37.52,0.0593,0.006,0.0417,631.088,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-03",3,1.24,56.36,,0,0.001,36.632,0.059,0.006,0.0413,616.364,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-04",3,1.74,83.76,,0,0.001,53.856,0.0593,0.007,0.013,906.676,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-05",7,5.49,300.65,,0.001,0.001,185.339,0.059,0.015,0.0124,3119.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-06",3,1.48,68.88,,0,0.001,43.912,0.059,0.006,0.019,739.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-08",2,1.22,54.9,,0,0.001,35.52,0.059,0.005,0.027,597.671,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-09",2,1.24,65.68,,0,0.001,40.147,0.059,0.007,0.026,675.509,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-10",3,1.49,77.95,,0,0.001,47.923,0.0593,0.007,0.0183,805.731,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-11",2,1.22,56.7,,0,0.001,36.154,0.06,0.006,0.019,607.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-12",3,1.48,70.36,,0,0.001,45.061,0.0593,0.006,0.019,757.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-14",2,1.22,54.9,,0,0.001,35.746,0.059,0.006,0.0295,601.444,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-15",3,1.23,57.22,,0,0.001,36.828,0.059,0.006,0.0453,620.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-16",4,2.23,134.12,,0,0.001,79.672,0.0593,0.008,0.037,1339.378,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-17",3,1.47,68.1,,0,0.001,43.86,0.059,0.006,0.0193,737.77,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-18",4,2.17,110.1,,0,0.001,68.979,0.0593,0.007,0.0318,1159.882,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-20",2,1.23,55.68,,0,0.001,36.18,0.059,0.005,0.0265,608.778,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-21",5,2.45,112.25,,0,0.001,72.232,0.059,0.009,0.0354,1215.493,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-22",3,1.49,96.19,,0,0.001,55.423,0.059,0.007,0.042,933.252,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-23",5,2.94,157.49,,0,0.001,96.391,0.0592,0.012,0.0366,1621.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-24",6,3.46,236.14,,0.001,0.001,134.265,0.059,0.014,0.0293,2260.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-28",2,1.22,56.12,,0,0.001,36.391,0.06,0.006,0.027,611.571,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-29",2,1.22,55.25,,0,0.001,35.886,0.059,0.006,0.0275,603.439,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-11-30",3,1.24,55.36,,0,0.001,36.056,0.059,0.005,0.0437,606.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-03",1,0.02,0,,0,0,0.142,0.059,0,0.086,2.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-05",4,2.44,112.88,,0,0.001,72.995,0.059,0.011,0.0198,1228.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-07",3,1.48,127.62,,0,0.001,67.968,0.059,0.008,0.0427,1144.57,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-08",3,1.22,56.82,,0,0.001,36.26,0.0597,0.007,0.0453,610.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-10",5,2.46,113.64,,0,0.001,72.366,0.0592,0.011,0.0336,1216.991,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-11",2,1.22,70.04,,0,0.001,41.401,0.059,0.006,0.026,696.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-12",2,1.24,55.43,,0,0.001,35.701,0.059,0.006,0.0275,600.306,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-14",4,3.47,198.02,,0.001,0.001,119.659,0.0593,0.01,0.0123,2012.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-16",3,1.47,72.49,,0,0.001,45.317,0.0593,0.007,0.0463,763.146,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-22",4,2.47,151.45,,0,0.001,88.901,0.059,0.012,0.0193,1494.896,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-25",3,1.72,86.52,,0,0.001,53.828,0.059,0.007,0.0137,905.472,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-02",2,1.75,144.54,,0,0.001,76.962,0.059,0.009,0.015,1294.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-03",8,7.32,803.4,,0.002,0.001,406.82,0.059,0.029,0.0126,6844.02,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-04",2,1.15,80.05,,0,0.001,44.315,0.0595,0.003,0.007,745.68,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-09",2,1.23,58.25,,0,0.001,35.709,0.059,0.006,0.0205,600.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-14",2,1.22,58.32,,0,0.001,35.561,0.059,0.006,0.0215,598.795,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-17",2,1.22,57.67,,0,0.001,35.545,0.059,0.006,0.0195,598.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-19",2,1.08,107.28,,0,0.001,54.808,0.059,0.008,0.074,922.612,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-20",1,0.15,1.5,,0,0.001,1.74,0.059,0,0.005,29.31,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-23",2,1.23,62.31,,0,0.001,37.449,0.059,0.007,0.0215,630.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-25",4,2.98,183.48,,0.001,0.001,104.794,0.059,0.011,0.0393,1763.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-28",3,1.23,58.11,,0,0.001,35.705,0.0593,0.006,0.0493,601.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-30",2,1.23,63.28,,0,0.001,37.827,0.059,0.007,0.0165,636.359,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-01",1,0.08,1.28,,0,0.001,1.216,0.059,0.001,0.135,20.528,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-02",5,2.88,229.32,,0.001,0.001,123.232,0.0592,0.014,0.0164,2074.482,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-03",2,1.23,57.13,,0,0.001,35.407,0.059,0.006,0.016,595.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-05",2,1.25,104.53,,0,0.001,53.392,0.059,0.01,0.0185,897.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-16",4,3.08,259.28,,0.001,0.001,139.6,0.059,0.012,0.0365,2348.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-17",3,1.45,63.8,,0,0.001,40.63,0.0593,0.006,0.0137,683.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-20",5,3.73,259.21,,0.001,0.001,145.132,0.059,0.013,0.0122,2442.012,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-23",2,1.48,106.54,,0,0.001,58.748,0.059,0.008,0.021,988.942,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-24",2,1.22,57.67,,0,0.001,35.968,0.059,0.006,0.019,605.347,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-25",10,5.71,485.71,,0.001,0.001,260.127,0.0592,0.026,0.0267,4375.027,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-26",3,1.23,57.48,,0,0.001,36.197,0.0593,0.006,0.0543,608.667,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-27",2,1.23,94.45,,0,0.001,51.079,0.059,0.008,0.0145,859.651,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-01",3,1.97,117.11,,0,0.001,67.657,0.059,0.011,0.0173,1137.911,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-02",2,1.23,61.44,,0,0.001,37.122,0.059,0.007,0.0325,624.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-03",2,1.23,59.37,,0,0.001,36.27,0.0595,0.006,0.03,609.75,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-04",2,1.23,58.25,,0,0.001,36.071,0.0595,0.006,0.0195,606.08,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-09",5,2.73,172.02,,0,0.001,98.308,0.0592,0.013,0.0178,1654.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-10",2,1.23,64.1,,0,0.001,38.889,0.0595,0.006,0.0185,654.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-12",4,2.98,307.84,,0.001,0.001,158.59,0.059,0.015,0.0375,2667.456,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-13",4,2.46,210.52,,0.001,0.001,112.133,0.059,0.018,0.0165,1885.975,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-14",3,2.73,275.13,,0.001,0.001,142.019,0.059,0.015,0.013,2389.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-15",2,1.23,67.02,,0,0.001,39.825,0.059,0.007,0.0205,670.685,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-16",2,1.23,58.76,,0,0.001,36.412,0.059,0.006,0.018,612.775,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-17",6,2.46,124.47,,0,0.001,75.402,0.0592,0.012,0.0473,1268.742,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-21",2,1.23,79.68,,0,0.001,44.91,0.059,0.007,0.0305,755.937,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-22",2,1.23,58.36,,0,0.001,36.514,0.0595,0.006,0.015,614.01,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-23",7,3.96,232.24,,0.001,0.001,135.881,0.059,0.016,0.0296,2286.471,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-24",3,2.73,243.04,,0.001,0.001,128.112,0.059,0.012,0.012,2156.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-26",6,4.73,443.98,,0.001,0.001,231.655,0.059,0.021,0.0158,3898.123,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-27",3,1.23,68.41,,0,0.001,40.401,0.0593,0.007,0.0487,679.094,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-28",4,2.48,242.77,,0.001,0.001,126.03,0.059,0.013,0.0188,2119.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-29",5,2.46,151.7,,0,0.001,87.579,0.0594,0.012,0.0384,1472.661,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-05",2,1.23,57.6,,0,0.001,35.934,0.059,0.006,0.0215,604.366,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-06",5,2.46,147.26,,0,0.001,84.854,0.0592,0.013,0.035,1429.105,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-18",2,1.22,58.24,,0,0.001,36.074,0.059,0.007,0.0345,607.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-19",2,1.12,55.52,,0,0.001,33.904,0.059,0.006,0.017,570.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-20",5,3.21,192.71,,0.001,0.001,111.949,0.059,0.013,0.0372,1883.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-23",1,1,0,,0,0.001,0.2,0.067,0,0.009,3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-24",5,3.44,292.18,,0.001,0.001,156.319,0.059,0.017,0.0128,2630.013,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-25",2,1.21,58.51,,0,0.001,36.283,0.059,0.006,0.0185,611.323,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-04-30",4,3.23,233.16,,0.001,0.001,128.709,0.059,0.012,0.0123,2166.12,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-01",8,4.94,316.41,,0.001,0.001,180.851,0.0591,0.022,0.0184,3041.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-04",5,3.48,284.27,,0.001,0.001,153.15,0.059,0.017,0.0138,2577.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-05",11,8.46,795.77,,0.002,0.001,417.133,0.0592,0.034,0.0188,7021.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-07",3,1.21,56.15,,0,0.001,35.213,0.0593,0.006,0.05,591.859,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-08",5,2.67,190.68,,0.001,0.001,105.592,0.0592,0.014,0.0186,1777.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-09",3,1.98,190.95,,0.001,0.001,99.162,0.059,0.011,0.0213,1668.155,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-11",6,2.98,260.12,,0.001,0.001,136.322,0.0593,0.016,0.033,2293.173,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-12",3,1.73,136.56,,0,0.001,72.772,0.059,0.01,0.048,1224.431,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-15",2,1.21,78.98,,0,0.001,44.561,0.059,0.008,0.0305,749.221,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-16",3,1.96,130.12,,0,0.001,73.464,0.059,0.009,0.0147,1235.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-21",3,2.23,182.75,,0,0.001,98.3,0.0593,0.01,0.015,1653.969,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-26",4,2.71,208.4,,0.001,0.001,115.163,0.0595,0.012,0.0123,1936.964,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-27",2,1.48,118.4,,0,0.001,64.496,0.059,0.008,0.0175,1084.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-29",7,5.25,285.37,,0.001,0.001,173.098,0.0594,0.015,0.0226,2912.877,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-30",3,1.71,84.81,,0,0.001,52.356,0.059,0.007,0.0143,880.597,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-02",3,1.21,57.1,,0,0.001,35.346,0.059,0.006,0.0473,595.367,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-08",2,1.21,79.2,,0,0.001,44.715,0.059,0.007,0.029,752.862,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-16",2,1.23,85.98,,0,0.001,48.069,0.059,0.007,0.0285,809.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-20",3,1.21,56.49,,0,0.001,36.094,0.059,0.006,0.0443,607.289,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-23",2,1.21,57.98,,0,0.001,36.416,0.059,0.008,0.021,612.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-27",2,1.23,113.22,,0,0.001,59.49,0.059,0.01,0.0315,1000.386,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-03",2,1.23,88.53,,0,0.001,49.236,0.059,0.007,0.028,828.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-04",2,1.48,134.57,,0,0.001,71.068,0.059,0.009,0.0145,1196.623,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-05",3,2.21,173.13,,0,0.001,94.952,0.059,0.01,0.0213,1598.049,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-06",3,1.71,150.2,,0,0.001,79.818,0.059,0.009,0.02,1343.549,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-07",6,2.44,163.55,,0,0.001,92.502,0.059,0.014,0.044,1557.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-09",5,2.46,167.22,,0,0.001,94.312,0.0594,0.014,0.0364,1585.567,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-10",6,4.2,310.9,,0.001,0.001,173.77,0.0593,0.015,0.0207,2922.635,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-11",7,5.73,517.05,,0.001,0.001,274.683,0.059,0.02,0.0129,4623.387,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-12",5,3.21,309.38,,0.001,0.001,161.305,0.059,0.014,0.0288,2715.101,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-14",2,1.21,80.63,,0,0.001,45.68,0.0595,0.007,0.014,768.705,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-17",7,3.92,257.33,,0.001,0.001,146.611,0.0591,0.017,0.0387,2467.207,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-18",2,1.21,57.6,,0,0.001,36.257,0.059,0.005,0.014,610.163,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-20",3,1.21,58.36,,0,0.001,36.5,0.0593,0.007,0.046,613.674,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-21",3,1.21,60.36,,0,0.001,37.103,0.0597,0.006,0.043,624.258,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-24",2,1.21,67.21,,0,0.001,40.169,0.059,0.007,0.02,675.983,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-25",3,1.48,81.9,,0,0.001,48.955,0.059,0.008,0.0213,824.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-26",3,2.48,181.68,,0.001,0.001,101.236,0.059,0.012,0.015,1704.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-27",5,3.21,228.23,,0.001,0.001,127.022,0.0594,0.012,0.0282,2138.355,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-28",4,2.21,158.28,,0,0.001,88.368,0.0595,0.01,0.0333,1487.082,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-29",4,2.46,125.9,,0,0.001,77.588,0.0593,0.008,0.0355,1304.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-30",4,3.46,253.87,,0.001,0.001,141.431,0.059,0.013,0.0113,2379.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-07-31",7,4.96,414.24,,0.001,0.001,223.081,0.059,0.02,0.0123,3754.615,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-01",5,3.21,220.28,,0.001,0.001,125.27,0.059,0.012,0.0298,2107.878,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-02",5,3.21,298.49,,0.001,0.001,157.765,0.059,0.013,0.0292,2655.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-03",4,2.21,154.41,,0,0.001,86.728,0.059,0.008,0.0348,1460.109,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-04",2,1.23,71.61,,0,0.001,42.162,0.059,0.007,0.0175,708.981,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-08",3,1.25,99.4,,0,0.001,54.125,0.0593,0.008,0.0427,911.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-09",3,1.71,96.23,,0,0.001,58.034,0.059,0.008,0.0163,976.203,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-10",3,1.48,75.73,,0,0.001,46.656,0.0593,0.007,0.02,785.586,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-11",3,1.21,55.49,,0,0.001,35.462,0.059,0.006,0.044,596.496,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-12",4,2.98,173.68,,0.001,0.001,103.146,0.059,0.01,0.0118,1735.374,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-13",7,5.73,493.62,,0.001,0.001,264.676,0.059,0.019,0.0097,4453.819,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-14",8,7.05,469.05,,0.001,0.001,268.55,0.0591,0.021,0.0094,4520.92,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-15",7,5.96,392.76,,0.001,0.001,227.106,0.059,0.016,0.01,3821.762,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-16",7,5.21,374.36,,0.001,0.001,210.818,0.059,0.016,0.0227,3549.177,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-17",9,7.71,453.94,,0.001,0.001,265.938,0.0592,0.019,0.0092,4475.247,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-18",11,9.47,672.83,,0.002,0.001,364.743,0.059,0.027,0.0111,6137.321,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-19",9,7.96,717.77,,0.002,0.001,372.731,0.059,0.028,0.0092,6272.231,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-20",7,5.98,539.6,,0.001,0.001,287.785,0.059,0.022,0.0087,4844.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-21",6,4.21,304.25,,0.001,0.001,171.498,0.0592,0.015,0.0245,2886.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-22",5,3.15,238.39,,0.001,0.001,132.077,0.0592,0.013,0.0076,2222.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-23",3,1.48,128.12,,0,0.001,68.644,0.0593,0.009,0.0207,1155.271,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-24",6,4.21,342.15,,0.001,0.001,185.103,0.0592,0.015,0.0253,3114.099,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-25",7,5.21,385.99,,0.001,0.001,215.307,0.0591,0.017,0.0226,3623.653,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-26",5,3.21,248.25,,0.001,0.001,136.195,0.0592,0.011,0.0284,2290.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-27",8,6,498.05,,0.001,0.001,269.88,0.0593,0.021,0.0131,4540.59,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-28",5,3.75,235.35,,0.001,0.001,136.765,0.059,0.012,0.0112,2300.38,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-29",4,2.23,177.26,,0,0.001,96.788,0.059,0.01,0.0355,1628.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-08-31",3,1.21,56.36,,0,0.001,35.852,0.0597,0.006,0.0443,603.489,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-01",3,1.25,103.75,,0,0.001,56.55,0.0593,0.008,0.043,952.235,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-03",3,1.5,123.87,,0,0.001,67.404,0.059,0.008,0.0197,1134.481,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-04",7,5.48,480.83,,0.001,0.001,257.497,0.0591,0.02,0.0124,4332.831,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-05",11,10.62,882.74,,0.002,0.001,478.936,0.059,0.034,0.0092,8059.976,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-06",15,12.6,1122.86,,0.003,0.001,599.814,0.0591,0.042,0.0095,10091.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-07",6,5.08,303.48,,0.001,0.001,179.784,0.059,0.014,0.009,3026.437,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-08",10,7.35,557.47,,0.002,0.001,307.825,0.0594,0.027,0.0164,5178.143,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-09",12,9.8,951.8,,0.003,0.001,497.148,0.0591,0.034,0.0118,8365.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-10",4,2.22,109.62,,0,0.001,68.316,0.059,0.008,0.0343,1149.654,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-11",6,3.66,323.52,,0.001,0.001,170.88,0.0592,0.02,0.027,2877.314,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-12",4,2.73,220.13,,0.001,0.001,119.214,0.0593,0.011,0.011,2005.625,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-13",3,1.72,146.2,,0,0.001,78.14,0.059,0.009,0.013,1313.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-14",3,1.22,55.8,,0,0.001,35.698,0.059,0.006,0.0423,600.418,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-15",3,1.22,55.72,,0,0.001,35.566,0.0597,0.006,0.0417,597.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-16",5,3.97,287.32,,0.001,0.001,160.396,0.059,0.014,0.0114,2699.62,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-17",3,1.24,56.12,,0,0.001,36.024,0.059,0.006,0.0447,605.852,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-18",3,1.24,56.96,,0,0.001,36.572,0.0593,0.006,0.042,615.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-19",4,2.74,235.38,,0.001,0.001,125.824,0.0593,0.014,0.0333,2117.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-20",3,1.74,99.22,,0,0.001,58.632,0.059,0.008,0.0203,986.533,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-21",4,2.25,165.86,,0,0.001,91.516,0.0593,0.01,0.032,1540.026,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-22",6,4.22,363.02,,0.001,0.001,193.954,0.0592,0.015,0.0235,3261.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-23",5,3.25,262.38,,0.001,0.001,141.715,0.059,0.013,0.028,2382.901,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-24",6,4.22,359.8,,0.001,0.001,192.7,0.059,0.015,0.0242,3241.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-27",3,1.22,55.8,,0,0.001,35.522,0.0593,0.006,0.0423,598.064,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-28",8,5.47,366.02,,0.001,0.001,208.409,0.0591,0.018,0.0201,3506.954,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-29",2,1.12,56.36,,0,0.001,35.368,0.06,0.006,0.0605,594.216,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-09-30",8,4.09,247.21,,0.001,0.001,144.831,0.059,0.014,0.0214,2436.457,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-01",6,4.22,219.7,,0.001,0.001,134.956,0.0593,0.012,0.026,2269.94,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-02",3,1.73,155.25,,0,0.001,81.838,0.059,0.009,0.021,1377.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-03",5,3.48,259.68,,0.001,0.001,142.601,0.0594,0.012,0.015,2398.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-04",3,1.74,109.44,,0,0.001,63.268,0.059,0.009,0.0137,1064.754,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-05",6,4.74,375.26,,0.001,0.001,204.724,0.0592,0.017,0.0282,3444.032,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-06",5,3.24,172.48,,0.001,0.001,105.668,0.0594,0.01,0.029,1777.588,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-07",5,3.25,258.73,,0.001,0.001,141.191,0.059,0.013,0.0278,2375.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-08",3,1.22,57.9,,0,0.001,36.694,0.0597,0.006,0.0443,618.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-09",4,2.22,213.12,,0.001,0.001,111.934,0.0593,0.011,0.0325,1882.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-12",7,5.02,396.7,,0.001,0.001,218.558,0.059,0.019,0.025,3678.562,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-13",10,7.45,514.57,,0.001,0.001,292.134,0.0591,0.022,0.0223,4914.736,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-14",10,8.23,673.93,,0.002,0.001,367.067,0.059,0.025,0.0172,6176.014,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-15",6,4.22,214.92,,0.001,0.001,134.39,0.059,0.011,0.0252,2261.952,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-16",4,2.25,109.37,,0,0.001,69.359,0.0593,0.008,0.034,1166.313,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-17",5,3.23,232.32,,0.001,0.001,130.906,0.0592,0.012,0.0286,2202.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-18",11,6.96,579.85,,0.002,0.001,313.951,0.059,0.029,0.0219,5282.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-19",4,2.22,130.7,,0,0.001,77.234,0.059,0.008,0.0335,1299.614,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-20",4,2.22,119.6,,0,0.001,73.198,0.059,0.008,0.0338,1231.272,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-21",4,2.22,114.7,,0,0.001,70.868,0.059,0.008,0.0333,1192.158,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-22",12,7.44,594.38,,0.002,0.001,323.844,0.059,0.032,0.0203,5450.547,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-25",2,1.22,56.47,,0,0.001,36.13,0.059,0.006,0.0305,607.971,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-26",2,1.47,69.78,,0,0.001,44.236,0.059,0.009,0.022,744.106,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-27",2,1.24,87.42,,0,0.001,49.29,0.059,0.008,0.0175,828.816,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-01",4,2.46,115.93,,0,0.001,73.985,0.0595,0.008,0.0123,1244.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-02",4,2.25,115.49,,0,0.001,71.346,0.059,0.008,0.0328,1201.647,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-03",3,1.24,56.36,,0,0.001,36.02,0.059,0.006,0.0413,606.436,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-04",3,2,97.68,,0,0.001,61.478,0.059,0.008,0.015,1033.672,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-05",7,5.74,317.97,,0.001,0.001,193.369,0.059,0.015,0.013,3255.058,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-06",7,3.72,205.5,,0.001,0.001,123.298,0.0591,0.014,0.026,2074.715,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-07",3,1.22,55.8,,0,0.001,35.31,0.0593,0.006,0.045,593.938,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-08",3,1.47,69.1,,0,0.001,43.59,0.0593,0.007,0.0217,732.965,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-11",3,1.47,69.22,,0,0.001,43.908,0.0593,0.007,0.022,739.358,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-12",3,1.48,69.36,,0,0.001,44.226,0.059,0.007,0.0217,744.04,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-14",6,2.72,125.71,,0,0.001,80.627,0.0592,0.012,0.0302,1357.104,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-15",3,1.23,56.22,,0,0.001,36.109,0.059,0.006,0.0453,608.425,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-16",4,2.23,142.09,,0,0.001,82.26,0.059,0.009,0.0375,1384.916,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-17",3,1.72,83,,0,0.001,52.06,0.059,0.007,0.0147,876.152,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-18",3,1.33,68.22,,0,0.001,42.26,0.059,0.006,0.0423,710.965,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-19",2,1.22,56.67,,0,0.001,36.047,0.059,0.006,0.0145,606.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-20",2,0.99,43.5,,0,0.001,28.119,0.059,0.006,0.0645,473.538,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-21",3,1.72,82.07,,0,0.001,52.259,0.0593,0.007,0.0223,879.033,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-22",3,1.72,82.4,,0,0.001,52.093,0.0593,0.007,0.0223,876.827,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-23",7,3.94,221.92,,0.001,0.001,133.146,0.0591,0.016,0.0259,2241.982,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-24",13,10.45,927.25,,0.002,0.001,491.535,0.0591,0.033,0.0186,8268.628,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-29",3,1.72,82.79,,0,0.001,52.419,0.059,0.007,0.023,882.583,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-11-30",3,1.52,104.56,,0,0.001,58.58,0.059,0.008,0.0453,985.84,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-06",1,0.03,0,,0,0.001,0.258,0.059,0,0.051,4.365,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-07",5,2.03,90.93,,0,0.001,58.212,0.059,0.016,0.0342,980.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-08",1,0.42,13.44,,0,0.001,9.534,0.059,0.004,0.051,160.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-09",5,2.47,114.4,,0,0.001,72.459,0.0594,0.011,0.0308,1218.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-10",4,2.7,158.38,,0,0.001,92.709,0.059,0.014,0.0208,1559.892,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-11",3,1.47,69.1,,0,0.001,43.49,0.0593,0.007,0.022,732.55,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-12",3,1.72,83.79,,0,0.001,52.194,0.059,0.007,0.022,878.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-14",2,1.24,56.82,,0,0.001,36.122,0.0595,0.006,0.016,607.352,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-15",3,1.47,69.1,,0,0.001,44.172,0.0593,0.007,0.022,743.147,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-16",4,2.44,113.34,,0,0.001,72.468,0.0595,0.012,0.0185,1218.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-18",3,1.72,85.92,,0,0.001,53.168,0.0593,0.007,0.014,894.504,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-20",5,2.47,117.6,,0,0.001,74.411,0.0592,0.013,0.034,1251.534,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-21",3,1.72,88.52,,0,0.001,54.364,0.0593,0.007,0.0143,914.556,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-25",5,2.94,178.91,,0.001,0.001,104.001,0.0594,0.016,0.0138,1749.443,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-27",3,1.22,66.84,,0,0.001,39.788,0.0593,0.007,0.0443,669.582,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-28",2,1.74,133.98,,0,0.001,72.558,0.059,0.008,0.0145,1221.741,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG2",,"2020-12-31",2,1.22,56.62,,0,0.001,35.7,0.0595,0.009,0.0225,600.853,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-02",4,2.98,290.22,,0.001,0.001,149.729,0.059,0.014,0.0108,2520.083,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-03",9,8.33,898.18,,0.002,0.001,457.303,0.059,0.03,0.0118,7692.835,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-04",1,0.65,42.25,,0,0.001,23.79,0.059,0.001,0.007,399.945,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-14",2,1.23,58.25,,0,0.001,35.89,0.059,0.007,0.0225,604.291,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-17",2,1.23,56.95,,0,0.001,35.746,0.059,0.006,0.019,601.894,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-19",2,1.23,58.38,,0,0.001,36.12,0.059,0.006,0.031,608.112,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-20",2,1.23,65.37,,0,0.001,38.826,0.059,0.006,0.015,654.246,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-23",3,1.5,81.8,,0,0.001,48.91,0.0597,0.007,0.0437,821.99,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-25",3,1.23,75.43,,0,0.001,42.963,0.059,0.007,0.045,722.675,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-30",2,1.23,79.35,,0,0.001,45.205,0.059,0.008,0.0225,760.571,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-02",3,1.23,57.56,,0,0.001,36.097,0.0593,0.006,0.049,607.142,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-03",4,2.46,115.96,,0,0.001,72.571,0.0593,0.011,0.0168,1221.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-05",2,1.25,104.53,,0,0.001,53.892,0.059,0.012,0.0205,907.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-16",4,3.08,254.44,,0.001,0.001,137.08,0.059,0.012,0.035,2306.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-17",3,2.4,133.2,,0,0.001,78.955,0.0593,0.008,0.0113,1327.64,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-24",2,1.23,57.6,,0,0.001,35.869,0.059,0.006,0.02,603.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-25",9,6.71,629.39,,0.002,0.001,329.35,0.0591,0.029,0.0102,5541.243,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-26",3,1.23,57.64,,0,0.001,36.215,0.0593,0.007,0.053,609.401,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-27",2,1.25,86.51,,0,0.001,47.684,0.059,0.008,0.0185,802.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-01",3,1.72,91.88,,0,0.001,54.816,0.0593,0.009,0.0243,922.7,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-02",2,1.23,62.1,,0,0.001,37.518,0.0595,0.007,0.031,631.512,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-03",2,1.23,58.38,,0,0.001,35.907,0.059,0.006,0.0295,604.548,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-04",2,1.23,58.25,,0,0.001,36.136,0.0595,0.006,0.019,607.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-09",2,1.23,64.05,,0,0.001,39.129,0.0595,0.006,0.019,658.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-10",3,1.25,68.28,,0,0.0007,40.657,0.059,0.006,0.0187,683.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-14",8,4.5,402.31,,0.001,0.001,211.662,0.0591,0.03,0.0275,3561.171,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-21",2,1.22,58.32,,0,0.001,36.358,0.059,0.006,0.0205,611.766,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-23",4,2.46,138.06,,0,0.001,81.498,0.059,0.013,0.0263,1370.988,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-24",4,2.5,191.8,,0.001,0.001,103.495,0.059,0.015,0.0215,1741.283,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-26",5,3.98,396.5,,0.001,0.001,203.672,0.059,0.02,0.0348,3426.514,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-28",4,2.48,255.52,,0.001,0.001,131.082,0.059,0.014,0.019,2204.786,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-29",2,1.23,79.37,,0,0.001,45.198,0.059,0.007,0.016,761.13,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-05",2,1.23,57.6,,0,0.001,35.804,0.059,0.006,0.02,602.546,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-06",3,1.22,57.67,,0,0.001,35.491,0.059,0.006,0.0483,597.826,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-20",2,1.22,72.2,,0,0.001,41.902,0.059,0.007,0.0155,705.402,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-21",3,1.25,110.83,,0,0.001,58.286,0.0593,0.008,0.047,980.116,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-23",1,0.02,0,,0,0,0.138,0.059,0,0.064,2.334,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-24",7,3.96,248.46,,0.001,0.001,141.657,0.0591,0.017,0.02,2383.312,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-25",3,1.71,85.28,,0,0.001,52.753,0.059,0.006,0.0203,887.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-04-30",3,2.6,171.18,,0,0.001,96.332,0.059,0.009,0.0137,1622.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-01",8,4.19,306.01,,0.001,0.0009,168.418,0.0591,0.02,0.0105,2833.909,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-04",3,2,195,,0.001,0.001,100.265,0.059,0.012,0.0227,1688.206,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-05",11,8.37,765.56,,0.002,0.001,400.118,0.0592,0.033,0.023,6732.136,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-08",3,1.23,92.2,,0,0.001,50.088,0.0593,0.008,0.0467,842.137,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-09",3,2,189.3,,0,0.001,97.72,0.059,0.011,0.0207,1645.215,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-11",4,2.75,271.2,,0.001,0.001,138.07,0.059,0.014,0.013,2324.145,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-12",3,1.48,137,,0,0.001,71.196,0.0593,0.01,0.0473,1197.596,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-15",2,1.21,73.7,,0,0.001,42.262,0.059,0.008,0.032,710.941,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-16",3,1.73,98.99,,0,0.001,57.708,0.059,0.008,0.021,971.218,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-21",3,2.25,191.55,,0.001,0.001,101.55,0.059,0.01,0.0147,1709.93,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-26",4,2.71,203.24,,0.001,0.001,112.651,0.059,0.011,0.0118,1894.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-27",3,1.98,151.02,,0,0.001,83.12,0.059,0.009,0.0137,1399.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-29",7,5.25,296.49,,0.001,0.001,177.457,0.0593,0.014,0.021,2984.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-02",3,1.23,57.36,,0,0.001,35.542,0.0593,0.006,0.045,598.34,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-03",3,1.23,58.46,,0,0.001,35.936,0.0593,0.006,0.0443,605.316,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-08",2,1.48,113.06,,0,0.001,61.688,0.059,0.009,0.016,1037.242,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-16",3,2.46,159.44,,0,0.001,91.047,0.059,0.009,0.0123,1532.319,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-26",5,3.73,267.99,,0.001,0.001,148.87,0.0594,0.014,0.0116,2504.224,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-27",2,1.25,110.25,,0,0.001,58.085,0.059,0.009,0.0275,976.925,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-03",2,1.25,88.35,,0,0.001,48.985,0.059,0.007,0.027,824.825,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-04",5,2.73,193.72,,0.001,0.001,107.238,0.0592,0.014,0.0316,1804.95,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-05",2,1.71,120.36,,0,0.001,66.934,0.0595,0.012,0.0185,1125.958,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-06",3,1.5,133.05,,0,0.001,70,0.0593,0.009,0.0197,1177.45,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-07",5,2.46,176.45,,0,0.001,96.942,0.0594,0.013,0.0314,1630.337,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-09",2,1.5,138.6,,0,0.001,72.27,0.059,0.01,0.019,1215.39,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-10",5,3.73,262.74,,0.001,0.001,146.473,0.0594,0.012,0.011,2464.075,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-11",7,5.48,511.18,,0.001,0.001,267.031,0.059,0.019,0.012,4493.527,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-12",3,1.73,155.47,,0,0.001,81.412,0.0593,0.009,0.0123,1369.131,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-17",3,1.25,87.6,,0,0.001,48.155,0.059,0.007,0.043,810.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-18",2,1.23,57.41,,0,0.001,36.161,0.059,0.005,0.014,608.05,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-25",3,1.48,81.77,,0,0.001,48.624,0.0593,0.008,0.0213,817.718,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-26",3,2.48,168.08,,0,0.001,94.668,0.059,0.01,0.0133,1592.992,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-27",5,3.23,168.39,,0.001,0.001,102.434,0.0594,0.01,0.029,1722.478,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-28",4,2.23,157.42,,0,0.001,87.169,0.0593,0.01,0.033,1467.877,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-29",4,2.48,136.16,,0,0.001,81.574,0.0593,0.008,0.0335,1372.522,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-30",4,2.98,236.1,,0.001,0.001,127.58,0.059,0.011,0.0125,2147.606,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-07-31",4,2.98,264.62,,0.001,0.001,139.571,0.059,0.012,0.016,2349.357,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-01",5,3.21,248.44,,0.001,0.001,136.281,0.0592,0.012,0.0278,2292.917,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-02",4,2.23,187.62,,0.001,0.001,100.921,0.0593,0.01,0.0338,1698.118,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-03",4,2.23,152.65,,0,0.001,85.581,0.0593,0.008,0.034,1440.187,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-04",3,1.22,88.53,,0,0.001,48.7,0.0593,0.007,0.0437,819.129,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-09",2,1.48,79.56,,0,0.001,48.048,0.059,0.007,0.0215,808.084,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-10",3,1.5,74.35,,0,0.001,46.06,0.059,0.006,0.019,775.415,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-11",3,1.23,55.95,,0,0.001,35.378,0.059,0.006,0.043,595.019,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-12",4,2.71,145.48,,0,0.001,87.423,0.059,0.009,0.0165,1471.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-13",7,5.73,467.65,,0.001,0.001,251.52,0.059,0.019,0.0094,4233.073,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-14",8,7.05,483.05,,0.001,0.001,270.905,0.0591,0.021,0.009,4557.41,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-15",7,5.98,410.88,,0.001,0.001,232.388,0.0593,0.017,0.01,3909.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-16",6,4.21,281.44,,0.001,0.001,159.829,0.059,0.013,0.0248,2688.388,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-17",11,9.23,625.52,,0.002,0.001,346.863,0.0592,0.023,0.016,5837.494,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-18",11,9.48,766.09,,0.002,0.001,396.214,0.0591,0.027,0.0102,6665.237,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-19",9,8,686.1,,0.002,0.001,356.825,0.059,0.024,0.0083,6005.725,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-20",7,6,537.85,,0.001,0.001,284.485,0.0591,0.021,0.0084,4786.6,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-21",4,2.23,148.95,,0,0.001,84.054,0.0593,0.009,0.0333,1413.926,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-22",4,3.11,254.95,,0.001,0.001,135.991,0.0593,0.014,0.0105,2288.261,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-23",3,1.75,152.6,,0,0.001,80.723,0.059,0.01,0.013,1358.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-24",7,5.98,492.04,,0.001,0.001,263.835,0.059,0.02,0.0089,4438.774,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-25",7,5.23,401.55,,0.001,0.001,219.283,0.0593,0.017,0.0221,3687.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-26",5,3.23,208.58,,0.001,0.001,118.916,0.0592,0.01,0.0282,2001.526,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-27",8,6.73,567.44,,0.002,0.001,303.762,0.059,0.022,0.0114,5111.856,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-28",5,3.75,277.55,,0.001,0.001,152.495,0.0592,0.013,0.0108,2565.045,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-29",4,2.25,176.6,,0,0.001,95.47,0.0593,0.009,0.0343,1606.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-08-31",3,1.23,55.62,,0,0.001,35.578,0.059,0.006,0.0437,598.262,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-03",3,1.5,101.79,,0,0.001,57.085,0.059,0.008,0.0187,960.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-04",7,5.23,509.03,,0.001,0.001,265.557,0.059,0.02,0.0214,4469.223,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-05",11,9.87,862.72,,0.002,0.001,456.784,0.059,0.033,0.0091,7686.909,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-06",11,9.61,681.99,,0.002,0.001,380.476,0.0591,0.026,0.0076,6401.963,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-07",7,5.26,359.64,,0.001,0.001,202.566,0.059,0.016,0.0216,3409.072,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-08",9,6.01,414.52,,0.001,0.001,231.591,0.0591,0.021,0.0206,3898.265,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-09",10,7.54,720.94,,0.002,0.001,373.855,0.0591,0.027,0.0197,6291.48,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-10",4,2.22,148.62,,0,0.001,83.086,0.059,0.009,0.0325,1398.068,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-11",6,3.74,303.84,,0.001,0.001,161.868,0.0592,0.018,0.0258,2724.192,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-12",4,2.47,216.17,,0.001,0.001,112.936,0.0593,0.012,0.016,1900.343,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-14",3,1.24,101.12,,0,0.001,53.94,0.059,0.007,0.0407,907.488,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-15",3,1.24,56,,0,0.001,35.416,0.0593,0.006,0.0407,595.908,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-16",3,1.72,85.57,,0,0.001,52.873,0.059,0.006,0.0187,890.344,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-17",3,1.24,56.24,,0,0.001,35.536,0.059,0.005,0.042,598.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-19",4,2.75,238.74,,0.001,0.001,126.017,0.0593,0.011,0.0325,2119.719,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-20",3,1.74,121.84,,0,0.001,66.884,0.059,0.008,0.0187,1125.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-21",4,2.25,209.64,,0.001,0.001,108.23,0.0593,0.01,0.033,1822.114,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-22",4,2.24,174.24,,0,0.001,93.524,0.0595,0.01,0.0313,1574.464,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-23",3,1.25,56.13,,0,0.001,35.418,0.059,0.005,0.04,596.463,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-24",9,7.24,658.36,,0.002,0.001,343.06,0.0591,0.024,0.0177,5774.76,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-27",3,1.24,56,,0,0.001,35.34,0.0593,0.005,0.0407,594.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-28",5,3.47,183.87,,0.001,0.001,111.227,0.0592,0.011,0.0144,1871.777,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-29",4,2.62,145.08,,0,0.001,86.618,0.0593,0.011,0.037,1457.27,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-09-30",7,3.08,183.18,,0.001,0.001,105.886,0.0593,0.012,0.0226,1781.616,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-01",8,6.24,364,,0.001,0.001,212.28,0.0591,0.016,0.0209,3573.196,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-02",3,1.47,117.12,,0,0.001,62.762,0.0593,0.008,0.0183,1055.477,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-03",7,5.25,411.25,,0.001,0.001,220.565,0.0591,0.016,0.0223,3711.636,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-04",3,1.75,92.71,,0,0.001,55.418,0.0593,0.007,0.013,932.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-05",6,4.74,374,,0.001,0.001,201.884,0.0592,0.016,0.0263,3397.126,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-06",5,3.24,179.48,,0.001,0.001,107.344,0.059,0.01,0.0268,1806.096,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-07",7,5.24,386.36,,0.001,0.001,212.184,0.059,0.016,0.0216,3567.948,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-12",6,4.31,377.56,,0.001,0.001,200.094,0.0593,0.018,0.0263,3366.8,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-13",8,6.5,430.63,,0.001,0.001,244.51,0.059,0.018,0.0111,4114.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-14",9,7.23,550.13,,0.002,0.001,301.917,0.0591,0.022,0.0187,5079.093,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-15",6,4.25,265.51,,0.001,0.001,153.095,0.0592,0.013,0.0257,2576.834,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-16",6,4.23,218.03,,0.001,0.001,134.054,0.0592,0.011,0.0252,2255.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-17",5,3.23,216.39,,0.001,0.001,123.147,0.0592,0.011,0.0276,2071.713,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-18",8,5.97,533.42,,0.001,0.001,280.527,0.0591,0.021,0.0144,4719.794,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-19",4,2.24,188.88,,0.001,0.001,100.156,0.0593,0.01,0.0328,1685.98,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-21",4,2.22,114.2,,0,0.001,69.678,0.0593,0.007,0.034,1171.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-22",8,6.75,647.6,,0.002,0.001,335.795,0.059,0.025,0.0121,5651.745,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-26",2,1.22,57.15,,0,0.001,36.117,0.059,0.008,0.0205,608.233,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-01",5,2.49,126.93,,0,0.001,77.456,0.059,0.012,0.0348,1303.949,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-02",3,1.24,57.6,,0,0.001,36.564,0.059,0.006,0.041,614.688,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-03",3,1.24,55.6,,0,0.001,35.704,0.059,0.006,0.0417,600.476,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-04",3,1.99,96.7,,0,0.001,60.538,0.059,0.007,0.0143,1018.965,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-05",7,5.74,370.08,,0.001,0.001,211.617,0.0593,0.016,0.0124,3559.711,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-06",4,2.47,144.22,,0,0.001,84.162,0.0593,0.008,0.0165,1416.294,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-07",3,1.22,54.8,,0,0.001,34.88,0.0593,0.006,0.0467,587.37,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-08",3,1.47,69.1,,0,0.001,43.003,0.059,0.006,0.0223,723.661,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-11",3,1.49,69.4,,0,0.001,43.607,0.059,0.007,0.023,734.169,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-12",3,1.5,69.91,,0,0.001,43.874,0.059,0.007,0.021,739.363,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-13",2,1.24,56.67,,0,0.001,36.06,0.059,0.006,0.0295,607.318,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-14",3,1.5,69.54,,0,0.001,43.961,0.0597,0.006,0.02,738.807,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-15",3,1.25,56.51,,0,0.001,35.946,0.0593,0.006,0.0447,604.293,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-16",4,2.23,143.19,,0,0.001,81.414,0.059,0.009,0.0365,1370.51,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-17",3,1.47,69.45,,0,0.001,43.155,0.0593,0.006,0.0207,726.951,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-18",4,2.17,106.2,,0,0.001,66.002,0.0593,0.007,0.033,1111.382,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-20",3,1.25,56.85,,0,0.001,36.227,0.0593,0.007,0.0433,609.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-21",3,1.72,82.42,,0,0.001,51.685,0.0597,0.006,0.0203,869.137,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-22",3,1.74,82.97,,0,0.001,51.81,0.0593,0.007,0.0213,871.67,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-23",10,5.98,362.43,,0.001,0.001,210.182,0.0593,0.021,0.0218,3537.07,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-24",11,7.46,651.6,,0.002,0.001,343.22,0.0592,0.027,0.0265,5774.966,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-29",3,1.5,69.91,,0,0.001,43.848,0.059,0.007,0.0223,738.645,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-11-30",3,1.24,56.72,,0,0.001,36.036,0.0597,0.006,0.0427,606.956,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-05",5,2.46,115.26,,0,0.001,72.83,0.059,0.012,0.0334,1225.536,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-06",2,1.24,56.45,,0,0.001,36.024,0.0595,0.006,0.0155,606.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-07",4,2.24,205,,0.001,0.001,106.728,0.059,0.011,0.0353,1796.16,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-10",1,0.3,6.6,,0,0.001,5.37,0.059,0.003,0.067,90.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-11",3,1.47,69.45,,0,0.001,43.178,0.0597,0.006,0.0213,725.517,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-12",2,1.22,55.25,,0,0.001,35.015,0.059,0.006,0.0295,589.539,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-14",2,1.24,56.82,,0,0.001,35.75,0.059,0.006,0.015,602.54,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-16",4,2.44,112.72,,0,0.001,71.062,0.0593,0.012,0.0195,1196.168,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-20",3,1.25,56.98,,0,0.001,36.028,0.0597,0.006,0.045,606.09,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-25",4,2.47,138.92,,0,0.001,81.848,0.0593,0.009,0.018,1377.568,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-27",6,2.7,129.03,,0,0.001,80.042,0.059,0.011,0.028,1346.86,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-28",2,1.24,97.24,,0,0.001,51.868,0.059,0.009,0.017,873.135,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Pio Pico Energy Center LLC",57555,"CTG3",,"2020-12-31",2,1.22,56.18,,0,0.001,35.228,0.059,0.006,0.019,592.898,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-06",8,6.25,207.38,,0.001,0.001,128.329,0.0591,0.02,0.0405,2160.712,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-13",7,5.25,168.12,,0.001,0.001,104.999,0.0594,0.017,0.0433,1765.206,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-15",12,10.15,322.98,,0.001,0.001,201.504,0.0593,0.027,0.0214,3391.636,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-17",4,2.26,27.56,,0,0.001,24.432,0.0593,0.005,0.0475,411.78,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-29",4,2.21,52,,0,0.001,35.923,0.0595,0.006,0.068,605,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-13",4,2.7,60.58,,0,0.001,42.232,0.059,0.008,0.044,711.732,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-05",3,2.15,49.37,,0,0.001,34.038,0.0593,0.006,0.0203,572.966,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-12",4,2.33,56.99,,0,0.001,38.327,0.059,0.007,0.073,645.57,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-13",5,4.42,137.6,,0,0.001,85.888,0.059,0.012,0.0204,1446.068,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-16",11,8.38,260.84,,0.001,0.001,163.107,0.0594,0.022,0.0274,2744.047,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-17",10,8.09,249.86,,0.001,0.001,155.891,0.0593,0.02,0.018,2622.388,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-03",3,2.05,45.8,,0,0.001,31.87,0.0597,0.005,0.0203,535.575,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-02",3,2.25,30.65,,0,0.001,25.615,0.0597,0.006,0.0423,430.95,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-03",1,0.23,0.46,,0,0.001,1.495,0.06,0,0.02,25.001,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-07",6,4.34,127.4,,0,0.001,81.615,0.0592,0.01,0.0255,1373.13,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-18",13,10.55,229.13,,0.001,0.001,160.461,0.0594,0.02,0.0246,2699.451,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-19",13,10.35,180.61,,0.001,0.001,137.466,0.0595,0.011,0.0101,2311.442,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-20",8,6.15,99.6,,0,0.001,77.689,0.0595,0.01,0.0143,1307.111,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-22",6,5,127.1,,0,0.001,84.986,0.0593,0.015,0.0228,1430.618,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-23",8,5.91,114.8,,0,0.001,83.458,0.0595,0.013,0.0185,1403.17,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-25",11,9.22,215.53,,0.001,0.001,146.734,0.0592,0.021,0.0358,2472.537,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-26",5,3.98,118.42,,0,0.001,75.152,0.0592,0.01,0.0178,1265.064,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-27",7,5.91,136.86,,0,0.001,93.38,0.0591,0.01,0.0121,1573.139,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-28",6,4.27,129.47,,0,0.001,81.661,0.0593,0.011,0.0335,1374.215,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-29",2,1.85,23.35,,0,0.001,19.97,0.0595,0.003,0.021,336.44,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-30",9,7.26,140.01,,0.001,0.001,101.936,0.0594,0.014,0.0157,1713.783,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-05-31",3,2.02,23.42,,0,0.001,20.944,0.0597,0.004,0.0193,351.92,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-02",5,4.17,125.53,,0,0.001,78.798,0.0592,0.01,0.0166,1325.475,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-03",7,6.09,200.99,,0.001,0.001,123.584,0.0593,0.017,0.0177,2080.155,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-04",5,4.6,131.64,,0,0.001,83.878,0.0592,0.011,0.0168,1412.694,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-09",6,4.76,144.24,,0,0.001,90.62,0.0593,0.011,0.0368,1523.644,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-10",6,4.89,132.57,,0,0.001,86.077,0.059,0.011,0.019,1451.429,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-11",5,4.6,142.74,,0,0.001,89.606,0.0592,0.011,0.0154,1507.591,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-22",6,4.75,144.47,,0,0.001,91.09,0.0595,0.013,0.0465,1531.819,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-23",5,4.62,138.82,,0,0.001,87.46,0.0594,0.011,0.0146,1470.664,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-05",1,0.12,0,,0,0.001,0.624,0.059,0.001,0.203,10.536,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-10",6,4.93,141.96,,0,0.001,91.018,0.0595,0.014,0.0397,1530.666,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-11",5,4.78,140.01,,0,0.001,88.347,0.059,0.011,0.0148,1488.732,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-12",8,7.83,229.96,,0.001,0.001,144.815,0.0593,0.016,0.0136,2439.229,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-13",10,8.23,201.53,,0.001,0.001,134.886,0.0593,0.012,0.009,2270.16,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-14",9,6.81,157.27,,0.001,0.001,107.326,0.0594,0.008,0.0081,1804.45,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-27",9,8.05,207.1,,0.001,0.001,135.605,0.0594,0.017,0.0332,2281.125,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-28",12,9.43,194.18,,0.001,0.001,137.58,0.0593,0.016,0.0134,2314.889,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-29",8,7.2,241.72,,0.001,0.001,148.82,0.0593,0.019,0.0153,2503.22,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-30",10,8.03,226.83,,0.001,0.001,145.661,0.0591,0.017,0.0126,2451.259,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-07-31",9,8.13,284.83,,0.001,0.001,172.12,0.0594,0.025,0.0183,2894.821,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-01",8,6.13,170.55,,0.001,0.001,110.783,0.0593,0.016,0.0194,1863.886,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-03",5,4.02,124.84,,0,0.001,78.896,0.0594,0.01,0.0156,1327.164,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-09",9,7.54,186.4,,0.001,0.001,125.433,0.0592,0.014,0.0318,2112.803,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-10",8,6.12,145.38,,0.001,0.001,99.398,0.0591,0.011,0.0134,1672.786,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-12",9,7.27,237.75,,0.001,0.001,147.132,0.0593,0.02,0.0359,2475.809,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-13",9,8.37,289.59,,0.001,0.001,178.409,0.0593,0.023,0.0163,2999.581,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-14",16,15.7,588.4,,0.002,0.001,355.89,0.0591,0.046,0.0158,5991.81,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-15",22,20.9,741.05,,0.002,0.001,454.962,0.0593,0.056,0.0144,7650.769,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-16",22,20.91,784.65,,0.002,0.001,475.765,0.0593,0.059,0.0149,8005.658,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-17",24,24,936,,0.003,0.001,563.7,0.0592,0.071,0.015,9485.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-18",24,24,936,,0.003,0.001,564.4,0.0593,0.071,0.0149,9494.7,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-19",24,24,926,,0.003,0.001,559.2,0.0591,0.07,0.0149,9411.9,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-20",24,24,936,,0.003,0.001,563.6,0.0593,0.071,0.015,9481,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-21",24,23.2,828.4,,0.003,0.001,509.52,0.0592,0.061,0.0143,8575.12,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-22",10,9.1,319.5,,0.001,0.001,198.33,0.0592,0.025,0.0158,3337,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-23",12,11.12,397.76,,0.001,0.001,246.492,0.0593,0.025,0.0112,4146.458,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-24",15,14.9,549.9,,0.002,0.001,337.95,0.0595,0.041,0.0139,5682.91,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-25",19,17.27,631.41,,0.002,0.001,387.805,0.0592,0.048,0.0151,6525.02,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-26",12,11.87,433.44,,0.001,0.001,266.37,0.0592,0.034,0.0151,4484.641,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-27",24,24,917,,0.003,0.001,555.4,0.0593,0.075,0.0161,9344.6,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-28",24,24,776,,0.002,0.001,487.7,0.0591,0.067,0.0159,8215.1,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-29",23,21.92,650.12,,0.002,0.001,417.808,0.0593,0.053,0.0148,7027.644,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-30",21,19.15,392.73,,0.001,0.001,283.139,0.0592,0.033,0.0133,4764.397,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-08-31",20,18.78,680.81,,0.002,0.001,415.281,0.0593,0.056,0.0161,6984.911,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-01",19,17.97,613.67,,0.002,0.001,378.316,0.0594,0.052,0.0167,6364.502,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-02",19,18.55,575.05,,0.002,0.001,361.41,0.0593,0.048,0.0152,6082.16,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-03",24,24,567,,0.002,0.001,388.4,0.0593,0.048,0.0143,6538.2,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-04",24,24,908,,0.003,0.001,549.8,0.0592,0.073,0.0157,9249.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-05",24,24,913,,0.003,0.001,552.1,0.0593,0.072,0.0153,9289,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-06",24,24,777,,0.002,0.001,488.4,0.0593,0.062,0.0147,8219.4,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-07",24,24,911,,0.003,0.001,552.5,0.0592,0.069,0.0147,9296.3,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-08",24,23.23,857.76,,0.003,0.001,521.961,0.0594,0.07,0.016,8780.908,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-09",19,16.71,474.34,,0.002,0.001,306.498,0.0594,0.04,0.0165,5156.312,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-10",6,5.11,165.02,,0.001,0.001,104.079,0.0593,0.015,0.0177,1750.389,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-14",5,3.51,96.48,,0,0.001,63.82,0.0594,0.01,0.0534,1073.594,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-15",5,4.2,124.89,,0,0.001,81.345,0.0594,0.013,0.0202,1368.298,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-16",5,4.2,127.58,,0,0.001,81.924,0.0592,0.01,0.0164,1377.37,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-17",5,4.47,131.17,,0,0.001,85.235,0.0594,0.011,0.017,1432.846,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-19",7,6.2,187.08,,0.001,0.001,119.863,0.0594,0.016,0.0167,2016.599,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-21",6,4.53,135,,0,0.001,87.259,0.0592,0.013,0.0337,1469.267,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-23",5,4.2,123.92,,0,0.001,80.411,0.0592,0.011,0.0186,1353.095,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-24",3,1.97,33.89,,0,0.001,26.079,0.059,0.002,0.0287,439.435,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-26",1,0.1,0,,0,0.001,0.55,0.06,0.001,0.16,9.18,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-27",6,4.27,125.64,,0,0.001,81.073,0.0592,0.011,0.0447,1365.202,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-28",8,7.6,246.48,,0.001,0.001,157.212,0.0591,0.023,0.0183,2645.356,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-29",10,9.6,337,,0.001,0.001,208.336,0.0593,0.029,0.0163,3503.932,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-09-30",12,11.54,415.62,,0.001,0.001,254.46,0.0593,0.033,0.0158,4278.536,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-01",12,11.03,397.02,,0.001,0.001,241.082,0.0592,0.032,0.0153,4057.451,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-02",10,9.35,328.37,,0.001,0.001,200.795,0.0591,0.027,0.0157,3376.556,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-03",5,4.13,124.43,,0,0.001,78.914,0.0594,0.01,0.0152,1327.714,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-04",5,4.1,123.79,,0,0.001,78.706,0.0592,0.009,0.0146,1325.569,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-05",6,5.61,182.31,,0.001,0.001,114.399,0.0598,0.016,0.0173,1921.8,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-06",9,8.35,289.37,,0.001,0.001,178.718,0.0591,0.026,0.0182,3009.481,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-07",7,6.05,181.24,,0.001,0.001,116.283,0.0591,0.015,0.0157,1957.88,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-12",20,18.28,651.81,,0.002,0.001,397.184,0.0592,0.061,0.0281,6685.134,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-14",14,13.13,444.68,,0.001,0.001,275.539,0.0593,0.044,0.0208,4636.263,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-15",20,18.9,523.9,,0.002,0.001,342.97,0.0594,0.046,0.015,5769.095,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-16",20,18.9,572.98,,0.002,0.001,366.855,0.0592,0.052,0.0163,6175.13,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-17",22,20.98,569.23,,0.002,0.001,375.984,0.0593,0.05,0.0147,6327.755,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-18",14,13.15,465.5,,0.001,0.001,285.503,0.0591,0.041,0.0169,4803.564,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-19",16,14.01,376.46,,0.001,0.001,248.032,0.0593,0.033,0.0158,4175.332,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-20",13,12.85,476.2,,0.001,0.001,288.08,0.0592,0.043,0.0188,4847.585,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-21",24,24,931,,0.003,0.001,557.4,0.0591,0.079,0.0169,9381.5,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-22",10,8.44,289.2,,0.001,0.001,178.714,0.0591,0.026,0.0289,3009.018,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-23",9,7.5,217.5,,0.001,0.001,140.575,0.0591,0.017,0.0211,2366,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-24",10,8.36,238.88,,0.001,0.001,155.21,0.0595,0.02,0.0176,2609.119,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-25",12,10.43,280.78,,0.001,0.001,184.827,0.0593,0.023,0.0205,3111.312,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-26",13,11.27,358.41,,0.001,0.001,223.683,0.0592,0.028,0.0161,3764.877,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-27",13,11.04,369.16,,0.001,0.001,227.258,0.0592,0.028,0.0163,3823.646,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-29",8,6.28,205.75,,0.001,0.001,127.318,0.0595,0.018,0.044,2140.485,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-30",13,11.65,331.74,,0.001,0.001,215.15,0.0592,0.025,0.0146,3621.116,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-10-31",11,9.29,244.88,,0.001,0.001,163.501,0.0594,0.017,0.0124,2750.718,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-01",7,6.12,201.82,,0.001,0.001,127.31,0.0594,0.017,0.0176,2140.563,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-02",11,10.12,348.82,,0.001,0.001,215.435,0.0592,0.028,0.0178,3625.18,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-03",10,9.83,357.13,,0.001,0.001,218.032,0.0593,0.025,0.0153,3669.218,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-04",22,20.88,758.05,,0.002,0.001,464.525,0.0592,0.056,0.0141,7820.67,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-05",13,11.31,400.33,,0.001,0.001,246.623,0.0595,0.029,0.0151,4148.517,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-06",7,6.1,203.79,,0.001,0.001,125.462,0.0594,0.017,0.0183,2109.748,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-07",7,6.18,182.9,,0.001,0.001,115.468,0.0591,0.016,0.0183,1945.233,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-08",10,8.76,175.8,,0.001,0.001,126.08,0.0592,0.017,0.0164,2124.054,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-09",12,10.29,327.24,,0.001,0.001,203.516,0.0593,0.026,0.0159,3423.799,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-10",14,11.76,404.68,,0.001,0.001,247.445,0.0592,0.03,0.0158,4163.602,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-11",11,9.59,305.01,,0.001,0.001,190.932,0.0593,0.023,0.0152,3212.893,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-12",11,8.88,264.4,,0.001,0.001,167.637,0.0595,0.019,0.0158,2819.467,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-13",9,7.11,212.68,,0.001,0.001,134.98,0.0593,0.017,0.0166,2269.752,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-16",7,5.96,196.25,,0.001,0.001,121.333,0.059,0.016,0.0181,2043.548,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-17",8,7.08,238.57,,0.001,0.001,146.746,0.059,0.02,0.0178,2470.271,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-18",10,7.98,243.27,,0.001,0.001,154.615,0.059,0.022,0.0196,2603.784,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-19",7,6.12,200.45,,0.001,0.001,124.962,0.0591,0.018,0.0193,2103.875,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-20",10,8.6,262.32,,0.001,0.001,166.79,0.0593,0.021,0.0157,2808.049,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-22",5,3.78,67.46,,0,0.001,49.86,0.0592,0.009,0.0734,840.492,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-24",8,6.87,231.09,,0.001,0.001,141.058,0.0593,0.02,0.0369,2372.265,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-09",8,7.08,0,,0,0.001,43.896,0.06,0.029,0.078,734.196,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-10",15,12.85,364.03,,0.001,0.001,235.914,0.0592,0.029,0.0245,3970.867,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-11",13,11.13,326.33,,0.001,0.001,209.457,0.0595,0.032,0.0235,3521.716,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-12",9,8.68,296.16,,0.001,0.001,182.88,0.0593,0.023,0.0171,3074.132,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-13",12,8.9,283.46,,0.001,0.001,177.293,0.0593,0.022,0.0153,2983.886,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-14",13,11.17,376.72,,0.001,0.001,231.725,0.0591,0.027,0.0155,3903.198,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-15",15,13.69,476.59,,0.001,0.001,291.869,0.0592,0.034,0.0145,4912.491,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-16",16,14.43,503.63,,0.002,0.001,307.987,0.0591,0.039,0.0153,5181.672,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-17",12,10.18,329.35,,0.001,0.001,204.889,0.0594,0.026,0.0167,3447.445,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-18",13,10.93,368.69,,0.001,0.001,227.715,0.0592,0.025,0.0142,3833.41,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-19",9,8.2,263.28,,0.001,0.001,164.406,0.0593,0.02,0.0157,2766.247,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-20",7,6.37,216.57,,0.001,0.001,133.785,0.0594,0.02,0.0214,2249.757,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-21",12,9.97,327.57,,0.001,0.001,204.196,0.0592,0.029,0.0193,3436.487,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-22",8,7.03,244.92,,0.001,0.001,150.276,0.0594,0.019,0.0181,2528.488,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-23",10,8.3,288.48,,0.001,0.001,177.38,0.0596,0.025,0.0437,2980.646,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-24",11,10.25,348.46,,0.001,0.001,215.859,0.0593,0.03,0.0185,3632.005,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-25",8,7.2,222.88,,0.001,0.001,141.304,0.0593,0.02,0.0184,2378.484,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-26",9,7.3,244.48,,0.001,0.001,151.868,0.0592,0.022,0.0478,2556.318,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-27",10,8.75,258.52,,0.001,0.001,166.788,0.0594,0.021,0.0161,2805.321,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-28",16,13.98,483.63,,0.002,0.001,297.691,0.0593,0.039,0.0169,5010.54,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-29",13,11,368.5,,0.001,0.001,228.954,0.0594,0.03,0.0165,3851.371,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-30",11,9.06,287.31,,0.001,0.001,181.192,0.0595,0.026,0.0202,3045.264,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Algonquin Power Sanger",57564,"8",,"2020-12-31",7,6.3,211,,0.001,0.001,130.18,0.0594,0.016,0.0137,2191.53,"Pipeline Natural Gas",,"Combined cycle",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-01",1,0.4,34,,0,0.001,27.16,0.059,0.001,0.005,457.16,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-02",20,19.08,3184.31,,0.01,0.001,2040.284,0.059,0.119,0.009,34334.464,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-03",9,7.93,1277.76,,0.004,0.001,827.461,0.059,0.054,0.0172,13923.745,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-04",10,9.53,1568.21,,0.005,0.001,1010.808,0.059,0.063,0.0115,17008.507,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-05",19,17.79,3081.3,,0.01,0.001,1959.93,0.059,0.094,0.0058,32982.486,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-06",24,24,4160,,0.013,0.001,2635.6,0.059,0.124,0.0056,44351.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-07",24,24,4210,,0.013,0.001,2665.1,0.059,0.129,0.0058,44842.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-08",22,20.09,3313.81,,0.011,0.001,2128.091,0.059,0.103,0.0055,35810.156,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-09",19,16.87,2774.34,,0.009,0.001,1782.767,0.059,0.082,0.0051,30000.423,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-10",24,24,4380,,0.014,0.001,2745.7,0.059,0.131,0.0057,46196.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-11",12,10.85,1805.48,,0.006,0.001,1157.774,0.059,0.068,0.0098,19482.663,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-12",18,15.99,2718.01,,0.009,0.001,1733.308,0.059,0.081,0.0054,29166.559,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-13",18,15.29,2349.42,,0.008,0.001,1538.827,0.059,0.071,0.0053,25891.998,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-14",21,20.22,3532.1,,0.011,0.001,2237.056,0.059,0.106,0.0054,37645.728,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-15",24,24,4479,,0.014,0.001,2793.3,0.059,0.135,0.0058,46999.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-16",4,3.78,668.16,,0.002,0.001,421.632,0.059,0.02,0.0058,7094.624,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-05",3,1.15,68.6,,0,0.001,63.285,0.059,0.032,0.0393,1064.705,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-08",2,0.55,0,,0,0.001,12.435,0.0595,0.003,0.027,209.331,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-09",4,3.67,356.81,,0.001,0.001,282.871,0.059,0.023,0.0105,4760.367,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-10",12,11.09,1510.05,,0.005,0.001,1062.321,0.059,0.103,0.0123,17876.125,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-11",22,21.95,2601.65,,0.009,0.001,1879.995,0.059,0.107,0.0068,31632.695,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-15",16,15.77,2263.29,,0.008,0.001,1539.124,0.059,0.097,0.0084,25896.727,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-17",11,10.72,1261.84,,0.004,0.001,884.7,0.059,0.063,0.011,14888.156,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-18",15,12.8,1617.71,,0.006,0.001,1112.095,0.0591,0.059,0.0096,18711.836,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-19",8,6.84,1027.99,,0.003,0.001,671.691,0.059,0.044,0.0175,11303.812,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-21",11,10.9,1720.1,,0.006,0.001,1108.98,0.059,0.065,0.0083,18659.45,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-22",14,12.57,1918.61,,0.006,0.001,1246.359,0.059,0.067,0.0079,20970.43,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-23",13,11.5,1834.7,,0.006,0.001,1180.204,0.059,0.059,0.0076,19857.978,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-24",10,9.38,1441.58,,0.005,0.001,936.04,0.059,0.052,0.0093,15751.176,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-25",12,11.16,1698.61,,0.006,0.001,1102.989,0.059,0.058,0.0105,18557.985,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-26",10,8.7,1335.8,,0.004,0.001,865.52,0.059,0.049,0.0106,14564.31,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-27",7,5.66,774.95,,0.003,0.001,517.892,0.059,0.034,0.016,8716.126,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-28",7,5.41,836.65,,0.003,0.001,539.991,0.059,0.037,0.0174,9087.239,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-29",10,8.58,1220.18,,0.004,0.001,804.432,0.059,0.05,0.0152,13536.254,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-06-30",7,5.82,891.74,,0.003,0.001,579.172,0.059,0.039,0.0197,9746.459,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-01",7,5.99,923.42,,0.003,0.001,595.919,0.059,0.038,0.0144,10028.254,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-02",7,6.07,950.04,,0.003,0.001,608.732,0.059,0.041,0.0147,10244.122,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-03",8,6.47,1012.82,,0.003,0.001,649.207,0.059,0.042,0.0141,10922.943,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-05",4,3.52,357.64,,0.001,0.001,266.228,0.059,0.031,0.0255,4479.544,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-06",15,13.37,1907.35,,0.006,0.001,1255.099,0.059,0.065,0.0094,21117.516,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-07",13,11.55,1756.7,,0.006,0.001,1132.385,0.059,0.063,0.0102,19057.34,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-08",14,12.46,2116.34,,0.007,0.001,1328.375,0.059,0.069,0.0081,22351.604,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-09",12,11.13,1813.35,,0.006,0.001,1151.131,0.059,0.063,0.0098,19368.278,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-10",12,10.59,1086.22,,0.004,0.001,809.704,0.059,0.049,0.0089,13623.214,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-13",15,14.47,1912.91,,0.006,0.001,1287.012,0.059,0.08,0.0114,21658.409,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-14",15,13.6,2171.32,,0.007,0.001,1384.32,0.059,0.072,0.0075,23292.54,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-15",14,11.48,1955.79,,0.006,0.001,1232.839,0.0591,0.07,0.0084,20742.932,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-16",14,13.17,1847,,0.006,0.001,1224.964,0.059,0.068,0.0084,20613.861,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-17",15,12.95,2091.3,,0.007,0.001,1327.594,0.059,0.073,0.0079,22338.83,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-18",13,11.37,1636.4,,0.005,0.001,1080.22,0.059,0.058,0.0085,18176.868,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-19",13,11.37,1825.2,,0.006,0.001,1163.068,0.059,0.065,0.0085,19566.34,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-20",14,12.62,1815.96,,0.006,0.001,1196.976,0.059,0.067,0.0093,20140.72,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-21",13,11.65,1800.17,,0.006,0.001,1165.126,0.059,0.08,0.0122,19604.437,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-22",11,9.6,1492.06,,0.005,0.001,958.61,0.059,0.075,0.0157,16130.556,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-23",12,11.13,1660.69,,0.005,0.001,1076.283,0.059,0.073,0.0138,18115.172,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-24",11,9.56,1479.56,,0.005,0.001,949.152,0.0591,0.066,0.015,15970.332,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-25",12,10.87,1727.15,,0.006,0.001,1101.299,0.059,0.077,0.0149,18530.693,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-26",12,8.27,1129.77,,0.004,0.001,748.696,0.059,0.059,0.0171,12600.298,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-27",15,14.65,2506.55,,0.008,0.001,1572.32,0.059,0.1,0.0101,26453.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-28",16,14.49,2485.64,,0.008,0.001,1561.454,0.0591,0.097,0.0094,26274.605,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-29",24,23.73,4122.41,,0.013,0.001,2565.511,0.059,0.131,0.0061,43171.859,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-30",15,14.18,2559,,0.008,0.001,1589.402,0.059,0.1,0.01,26743.822,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-07-31",16,14.63,2513.8,,0.008,0.001,1571.861,0.059,0.099,0.0093,26449.726,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-01",14,12.39,2011.33,,0.006,0.001,1282.569,0.059,0.084,0.009,21583.557,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-02",14,11.67,1796.93,,0.006,0.001,1161.399,0.0591,0.078,0.0084,19543.089,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-03",14,12.46,2004.8,,0.006,0.001,1278.87,0.0591,0.083,0.0109,21518.12,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-04",12,10.37,1678.6,,0.005,0.001,1068.622,0.0591,0.073,0.0111,17981.311,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-05",11,9.67,1674.51,,0.005,0.001,1051.129,0.0591,0.076,0.0138,17684.332,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-06",12,10.42,1748.25,,0.006,0.001,1105.329,0.059,0.079,0.0122,18597.61,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-07",11,9.6,1547.74,,0.005,0.001,987.381,0.059,0.068,0.0147,16615.774,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-08",11,9.9,1653.55,,0.005,0.001,1047.945,0.059,0.072,0.0145,17633.5,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-09",13,11.83,2031.89,,0.006,0.001,1282.872,0.059,0.083,0.0132,21585.615,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-10",17,16.1,2829,,0.009,0.001,1765.59,0.059,0.098,0.0069,29710.44,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-11",15,13.45,2243.16,,0.007,0.001,1422.02,0.059,0.086,0.0095,23926.358,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-12",22,20.61,3017.51,,0.01,0.001,1986.631,0.059,0.098,0.0063,33428.251,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-13",17,14.19,2464.2,,0.008,0.001,1548.481,0.059,0.098,0.0107,26055.869,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-14",24,24,4538,,0.014,0.001,2796,0.059,0.141,0.006,47052.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-15",24,24,4243,,0.013,0.001,2654.5,0.059,0.134,0.006,44669.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-16",24,24,4345,,0.014,0.001,2707.4,0.059,0.137,0.006,45559.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-17",24,22.47,4032.11,,0.013,0.001,2521.644,0.059,0.128,0.0064,42432.038,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-18",24,24,4421,,0.014,0.001,2742.5,0.059,0.139,0.006,46148,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-19",24,24,4277,,0.013,0.001,2670,0.059,0.137,0.0061,44933.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-20",24,24,4051,,0.013,0.001,2556.8,0.059,0.129,0.006,43023,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-21",24,22.38,3966.04,,0.012,0.001,2468.514,0.059,0.125,0.0061,41535.834,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-22",16,15.22,2617.66,,0.008,0.001,1649.696,0.059,0.098,0.0112,27759.026,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-23",19,17.71,3089.11,,0.01,0.001,1935.933,0.059,0.099,0.0072,32574.582,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-24",24,24,4500,,0.014,0.001,2775.7,0.059,0.14,0.006,46710,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-25",24,24,4250,,0.013,0.001,2639.3,0.059,0.135,0.0061,44412.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-26",24,24,3927,,0.013,0.001,2477.4,0.059,0.125,0.006,41685.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-27",24,24,3680,,0.012,0.001,2376.9,0.059,0.12,0.006,39995.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-28",22,19.28,3082.98,,0.01,0.001,1968.563,0.059,0.103,0.0072,33122.158,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-29",24,24,4120,,0.013,0.001,2590.4,0.059,0.131,0.006,43586.3,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-30",22,19.65,3361.16,,0.011,0.001,2113.218,0.059,0.108,0.006,35560.147,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-08-31",21,19.77,3237.75,,0.01,0.001,2058.303,0.059,0.107,0.007,34632.851,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-01",15,13.35,2105.64,,0.007,0.001,1344.452,0.059,0.086,0.0087,22621.082,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-02",14,12.58,1893.8,,0.006,0.001,1225.217,0.059,0.081,0.0089,20619.302,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-03",21,20.1,3267,,0.01,0.001,2073.49,0.059,0.109,0.0061,34887.39,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-04",24,24,4110,,0.013,0.001,2565.1,0.059,0.131,0.0061,43158.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-05",24,24,4056,,0.013,0.001,2560,0.059,0.128,0.006,43073.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-06",24,24,4272,,0.013,0.001,2668.3,0.059,0.131,0.0058,44896.1,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-07",24,24,4157,,0.013,0.001,2600.2,0.059,0.129,0.0059,43754.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-08",24,24,4107,,0.013,0.001,2569.3,0.059,0.13,0.006,43237.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-09",24,23.27,3534.11,,0.012,0.001,2284.194,0.059,0.115,0.006,38435.904,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-10",9,7.58,1243.5,,0.004,0.001,793.38,0.059,0.062,0.0097,13352.564,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-17",14,12.35,1936.05,,0.006,0.001,1251.33,0.059,0.094,0.0143,21057.05,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-19",9,8.11,1238.72,,0.004,0.001,805.68,0.059,0.072,0.0164,13555.143,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-22",12,10.87,1431.5,,0.005,0.001,969.188,0.059,0.081,0.0153,16308.003,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-23",12,10.86,1325.3,,0.005,0.001,920.114,0.059,0.069,0.013,15481.666,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-24",12,10.76,1577.64,,0.005,0.001,1038.334,0.059,0.08,0.0125,17473.572,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-25",7,5.81,939.9,,0.003,0.001,600.714,0.0591,0.053,0.011,10108.028,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-26",7,5.85,947.76,,0.003,0.001,605.147,0.059,0.053,0.0109,10183.26,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-27",10,8.55,1433.23,,0.005,0.001,907.254,0.059,0.064,0.0089,15267.04,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-28",13,11.98,1949.86,,0.006,0.001,1239.572,0.059,0.083,0.0138,20857.578,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-29",16,15.23,2499.38,,0.008,0.001,1585.558,0.059,0.098,0.011,26675.274,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-09-30",16,14.97,2571.77,,0.008,0.001,1613.644,0.059,0.095,0.0093,27152.957,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-01",17,15,2586.66,,0.008,0.001,1648.316,0.059,0.098,0.0105,27733.129,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-02",13,12,2064.86,,0.007,0.001,1316.782,0.059,0.084,0.0114,22157.698,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-03",10,9.03,1486.41,,0.005,0.001,960.302,0.059,0.068,0.0151,16160.01,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-04",8,7.01,1141.13,,0.004,0.001,735.953,0.059,0.064,0.0194,12382.395,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-05",11,9.15,1582.18,,0.005,0.001,1003.451,0.0592,0.074,0.0111,16884.451,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-06",13,11.2,1874,,0.006,0.001,1188.368,0.0591,0.081,0.0132,19994.318,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-07",11,9.86,1619.76,,0.005,0.001,1029.11,0.059,0.074,0.0092,17315.212,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-11",14,12.63,1874.22,,0.006,0.001,1226.2,0.059,0.102,0.018,20633.759,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-12",21,19.65,2946.76,,0.01,0.001,1904.064,0.059,0.099,0.0067,32037.118,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-13",21,19.67,3233.5,,0.01,0.001,2049.031,0.059,0.109,0.0065,34478.651,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-14",21,19.97,3264.2,,0.01,0.001,2071.642,0.059,0.109,0.0065,34858.452,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-15",21,20.17,3455,,0.011,0.001,2173.13,0.059,0.114,0.0065,36570.764,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-16",24,23.25,4151.5,,0.013,0.001,2586.05,0.059,0.132,0.0061,43512.875,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-20",23,22.28,3745.32,,0.012,0.001,2376.756,0.059,0.168,0.014,39988.832,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-21",21,20.41,3593.33,,0.011,0.001,2253.166,0.059,0.116,0.0062,37911.129,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-22",21,20.12,3529,,0.011,0.001,2202.596,0.059,0.119,0.0065,37063.884,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-23",21,20.06,3583.55,,0.011,0.001,2234.353,0.059,0.119,0.0073,37597.21,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-24",20,18.82,3187.84,,0.01,0.001,2010.114,0.0591,0.105,0.0061,33822.816,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-25",11,9.12,1571,,0.005,0.001,987.514,0.0592,0.088,0.0128,16616.644,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-26",24,24,4323,,0.014,0.001,2686,0.059,0.139,0.0061,45200,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-27",24,23.27,4252.98,,0.013,0.001,2633.856,0.059,0.135,0.0062,44319.282,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-10-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-05",24,23.28,3956.76,,0.013,0.001,2497.936,0.059,0.172,0.0129,42034.384,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-06",12,10.64,1738.53,,0.006,0.001,1100.827,0.0591,0.085,0.0124,18524.299,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-07",11,8.52,1315.65,,0.004,0.001,844.712,0.0591,0.078,0.016,14213.568,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-08",10,8.62,1352.35,,0.004,0.001,865.123,0.0591,0.083,0.0158,14556.498,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-09",10,9.4,1632.2,,0.005,0.001,1022.3,0.059,0.095,0.0205,17204.12,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-10",20,19.15,3280,,0.01,0.001,2055.335,0.059,0.108,0.0074,34583.84,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-11",12,10.55,1856.96,,0.006,0.001,1162.788,0.059,0.09,0.0172,19566.873,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-12",20,19.05,3285.94,,0.01,0.001,2060.036,0.059,0.109,0.0074,34661.441,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-13",9,7.42,1207.21,,0.004,0.001,770.943,0.059,0.07,0.0208,12971.319,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-14",7,6.27,998.43,,0.003,0.001,641.408,0.059,0.065,0.0194,10790.227,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-15",9,8.64,1368.15,,0.004,0.001,879.44,0.059,0.081,0.0177,14798.652,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-16",10,8.67,1442,,0.005,0.001,913.477,0.059,0.077,0.0144,15369.166,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-17",11,9.68,1633.5,,0.005,0.001,1033.29,0.059,0.083,0.0147,17388.808,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-18",20,19.2,2967.2,,0.01,0.001,1913.44,0.059,0.1,0.0069,32195.52,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-19",16,13.75,2299.5,,0.007,0.001,1461.175,0.0591,0.087,0.0103,24588.25,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-20",18,13.55,2021.09,,0.007,0.001,1323.271,0.0591,0.081,0.0092,22266.828,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-21",10,9.38,1670.82,,0.005,0.001,1046.388,0.059,0.095,0.0204,17607.346,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-22",10,8.7,1437.36,,0.005,0.001,916.432,0.059,0.086,0.0194,15421.502,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-23",20,18.87,3263.31,,0.01,0.001,2045.749,0.059,0.107,0.0073,34428.124,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-24",16,14.42,2445.2,,0.008,0.001,1553.842,0.059,0.091,0.0098,26148.326,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-25",10,8.18,1356.14,,0.004,0.001,865.946,0.059,0.078,0.0188,14571.846,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-01",23,22.32,3889.04,,0.012,0.001,2438.94,0.059,0.182,0.015,41041.792,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-02",21,19.91,3445.54,,0.011,0.001,2154.96,0.059,0.112,0.006,36262.421,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-03",24,24,4526,,0.014,0.001,2777.6,0.059,0.141,0.006,46741.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-04",22,20.3,3774.6,,0.012,0.001,2329.065,0.059,0.122,0.008,39188.745,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-05",20,18.78,3420.89,,0.011,0.001,2113.649,0.059,0.112,0.0079,35566.985,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-06",20,18.77,3396.78,,0.011,0.001,2106.728,0.059,0.113,0.0079,35451.452,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-07",24,24,4201,,0.013,0.001,2617.1,0.059,0.134,0.0061,44039.8,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-08",24,24,4275,,0.013,0.001,2651.8,0.059,0.136,0.0061,44621.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-09",21,19.77,3315.55,,0.011,0.001,2090.808,0.059,0.11,0.007,35181.555,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-10",24,24,4324,,0.014,0.001,2675.2,0.059,0.136,0.006,45013.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-11",24,24,4385,,0.014,0.001,2708.1,0.059,0.138,0.0061,45569.2,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-12",22,20.55,3657.08,,0.012,0.001,2278.246,0.059,0.12,0.0071,38337.105,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-13",24,24,4618,,0.014,0.001,2829.9,0.059,0.144,0.006,47620.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-14",22,20.62,3651.72,,0.012,0.001,2278.526,0.059,0.121,0.0062,38341.91,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-15",24,24,4530,,0.014,0.001,2783.1,0.059,0.142,0.006,46830.4,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-16",24,24,4583,,0.014,0.001,2810.9,0.059,0.144,0.0061,47298.9,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-17",21,19.79,3628.51,,0.011,0.001,2243.996,0.059,0.118,0.0073,37756.991,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-18",20,18.65,3346,,0.011,0.001,2080.095,0.0591,0.11,0.0067,35003.955,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-19",19,17.45,3009.76,,0.01,0.001,1891.045,0.0591,0.103,0.0067,31822.19,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-20",10,8.95,1555.26,,0.005,0.001,980.311,0.059,0.082,0.0176,16497.105,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-21",18,16.39,2847.49,,0.009,0.001,1801.492,0.059,0.099,0.0084,30312.305,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-22",17,15.16,2561.13,,0.008,0.001,1625.605,0.059,0.09,0.0087,27354.145,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-23",18,15.9,2686.55,,0.009,0.001,1704.689,0.059,0.095,0.0087,28685.735,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-24",21,20.11,3575.56,,0.011,0.001,2233.245,0.059,0.122,0.0075,37577.938,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-25",12,10.36,1799.73,,0.006,0.001,1130.327,0.059,0.091,0.0174,19021.479,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-26",10,9.42,1688.58,,0.005,0.001,1050.792,0.059,0.092,0.0186,17682.346,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-27",24,24,4330,,0.014,0.001,2678.9,0.059,0.135,0.006,45074.7,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-28",24,24,4527,,0.014,0.001,2778.6,0.059,0.141,0.006,46753.6,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-29",21,19.7,3530.9,,0.011,0.001,2194.75,0.059,0.116,0.007,36927.86,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-30",20,18.8,3340.04,,0.011,0.001,2087.104,0.059,0.111,0.0075,35119.22,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Lodi Energy Center",57978,"CT1",,"2020-12-31",11,9.83,1766.07,,0.006,0.001,1100.074,0.059,0.094,0.0191,18511.195,"Pipeline Natural Gas",,"Combined cycle",,"Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-10",3,1.88,58.12,,0,0.001,38.085,0.059,0.003,0.0137,641.498,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-01-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-02-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-13",2,0.66,20.16,,0,0.001,13.428,0.059,0.001,0.0395,225.744,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-03-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-24",10,8.75,174.79,,0.001,0.001,136.144,0.0593,0.008,0.0075,2294.004,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-04-30",1,0.6,17.4,,0,0.001,11.7,0.059,0.001,0.011,197.28,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-29",4,2.46,64.82,,0,0.001,45.14,0.059,0.004,0.017,759.782,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-01",3,1.55,35.04,,0,0.001,25.389,0.0593,0.002,0.022,427.686,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-02",3,1.53,26.7,,0,0.001,21.504,0.0593,0.002,0.013,361.742,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-03",3,2,61.5,,0,0.001,40.235,0.059,0.003,0.0113,677.88,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-10",3,2.25,57.15,,0,0.001,40.205,0.059,0.003,0.0093,677.585,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-26",4,2.43,68.17,,0,0.001,46.209,0.0593,0.004,0.0095,777.338,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-27",2,1.25,34.15,,0,0.001,23.305,0.06,0.002,0.01,391.53,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-28",7,3.17,59.6,,0,0.001,46.707,0.0594,0.004,0.0153,785.331,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-06-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-17",4,2.06,32,,0,0.0008,27.224,0.0595,0.002,0.0233,457.051,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-29",4,2.75,82.2,,0,0.001,54.795,0.0593,0.004,0.0103,921.33,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-30",6,4.5,137.8,,0,0.001,90.68,0.0592,0.006,0.0098,1526.125,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-07-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-12",4,3.25,94.55,,0,0.001,62.575,0.0593,0.005,0.0098,1052.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-14",10,9.22,253.86,,0.001,0.001,171.827,0.0596,0.013,0.0089,2888.881,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-15",5,4.63,81.12,,0,0.001,65.411,0.0592,0.005,0.0092,1102.734,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-17",9,8.47,299.38,,0.001,0.001,187.122,0.0592,0.013,0.0087,3147.714,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-18",8,7,291.54,,0.001,0.001,174.374,0.0594,0.013,0.0093,2932.962,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-28",5,3.93,75.85,,0,0.001,58.839,0.0594,0.004,0.0096,990.308,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-08-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-01",3,1.58,28.56,,0,0.001,22.826,0.0593,0.002,0.0117,384.936,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-02",2,0.95,32,,0,0.001,20.78,0.0595,0.002,0.015,349.19,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-04",10,9.02,161.56,,0.001,0.001,131.104,0.0594,0.009,0.0083,2204.348,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-05",10,9.2,219.84,,0.001,0.001,157.832,0.0592,0.011,0.008,2654.946,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-06",7,5.98,146.02,,0.001,0.001,104.232,0.0594,0.007,0.0104,1752.886,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-08",4,2.67,41.25,,0,0.001,35.416,0.0593,0.002,0.0098,596.3,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-11",3,2.5,66.15,,0,0.001,45.36,0.059,0.003,0.009,763.87,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-14",3,2,50.65,,0,0.001,35.74,0.059,0.003,0.0097,601.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-15",5,3.75,100.8,,0,0.001,69.455,0.0594,0.005,0.0102,1169.24,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-16",2,1.25,31.25,,0,0.001,22.105,0.059,0.002,0.0095,371.845,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-17",6,4.75,137.8,,0,0.001,92.755,0.0592,0.007,0.0098,1561.055,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-18",8,7.25,287.15,,0.001,0.001,176.585,0.0593,0.013,0.0086,2970.895,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-19",5,4.05,113.23,,0,0.001,76.703,0.0594,0.005,0.0084,1290.49,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-20",7,6.32,269.2,,0.001,0.001,161.86,0.0593,0.012,0.0089,2724.024,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-21",2,1.25,18,,0,0.001,15.955,0.059,0.001,0.0095,268.69,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-24",4,3.25,66.55,,0,0.001,49.995,0.0593,0.003,0.0085,842.225,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-28",3,2.5,72.3,,0,0.001,48.5,0.0593,0.004,0.009,816.32,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-29",3,2,58.05,,0,0.001,38.685,0.059,0.003,0.0123,651.36,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-01",6,3.22,78.23,,0,0.001,55.942,0.0592,0.005,0.018,941.939,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-02",4,2.75,49.6,,0,0.001,39.96,0.0595,0.003,0.0123,672.29,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-03",4,3,121.4,,0,0.001,73.86,0.0595,0.006,0.0098,1242.63,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-04",4,3.25,112,,0,0.001,70.435,0.0593,0.005,0.0093,1184.465,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-05",4,3.5,134.7,,0,0.001,82.59,0.0593,0.006,0.009,1390.18,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-06",3,2,53.95,,0,0.001,36.375,0.0593,0.003,0.0133,612.455,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-07",9,6.95,139,,0.001,0.001,106.815,0.0592,0.008,0.0116,1800.315,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-12",4,3,92.7,,0,0.001,60.725,0.0593,0.005,0.0118,1022.855,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-13",4,3,63.75,,0,0.001,47.62,0.059,0.004,0.0113,801.305,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-14",5,3.75,124.35,,0,0.001,80.21,0.0594,0.006,0.013,1349.345,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-15",5,4.25,91.25,,0,0.001,68.24,0.0592,0.005,0.009,1149.335,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-16",5,2.4,53.36,,0,0.001,39.436,0.0594,0.003,0.0146,663.197,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-20",3,2,35.7,,0,0.001,28.405,0.0597,0.002,0.0123,478.21,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-27",4,3.07,87.64,,0,0.001,59.634,0.0595,0.005,0.0125,1002.639,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-28",7,5.82,244.36,,0.001,0.001,147.94,0.0593,0.011,0.0097,2487.377,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-10-31",2,1.55,37.25,,0,0.001,26.625,0.059,0.002,0.0105,448.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-01",3,2,56,,0,0.001,38.5,0.059,0.003,0.009,648.74,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-06",7,4.12,108.15,,0,0.001,74.609,0.0593,0.005,0.01,1255.327,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-10",6,4.75,94.6,,0,0.001,72.06,0.0593,0.005,0.0098,1213.915,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-15",6,5.02,147.53,,0,0.001,97.855,0.0593,0.007,0.0097,1646.392,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-16",4,1.87,40.62,,0,0.001,30.095,0.0595,0.002,0.013,506.108,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-17",6,3.42,67.32,,0,0.001,51.36,0.0592,0.003,0.0128,864.357,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-20",2,1.27,20.85,,0,0.001,17.416,0.059,0.001,0.008,293.414,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-29",4,2.78,49.9,,0,0.001,40.423,0.0593,0.003,0.0128,681.524,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-01",10,7.29,135.16,,0.001,0.001,106.65,0.0593,0.008,0.012,1794.58,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-07",2,1.02,38.28,,0,0.001,23.784,0.0595,0.002,0.0165,400.332,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-09",4,2.4,36.68,,0,0.0008,31.508,0.059,0.003,0.0128,530.406,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-10",2,0.67,13.73,,0,0.001,10.366,0.059,0.001,0.02,174.593,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-19",7,5.75,105.6,,0,0.001,83.645,0.0594,0.006,0.0101,1407.14,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Delano Energy Center, LLC",58122,"GEN1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-06",1,0.53,18.55,,0,0.001,11.448,0.059,0.165,1.716,192.867,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-08",12,10.9,68.9,,0,0.001,87.75,0.0597,0.006,0.0075,1473.48,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-09",9,6.47,43.23,,0,0.001,53.772,0.0597,0.004,0.012,903.137,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-10",2,1.13,43.09,,0,0.001,26.136,0.0595,0.003,0.011,439.953,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-12",5,4.1,47.25,,0,0.001,43.019,0.0592,0.003,0.0084,724.632,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-13",2,0.46,8.14,,0,0.001,5.944,0.059,0.001,0.0205,100.16,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-16",2,1.5,61.75,,0,0.001,37.135,0.0595,0.002,0.0065,624.375,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-17",3,1.95,86.6,,0,0.001,51.315,0.059,0.003,0.0063,863.58,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-29",6,4.06,119.53,,0,0.001,76.427,0.0595,0.005,0.0243,1285.591,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-06-30",3,0.98,27.76,,0,0.001,17.886,0.059,0.002,0.012,301.04,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-01",8,5.3,136.58,,0,0.001,89.383,0.0596,0.005,0.0096,1501.876,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-02",8,6.51,165.64,,0.001,0.001,109.408,0.0591,0.006,0.0074,1840.633,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-03",9,8.05,226.88,,0.001,0.001,146.061,0.0594,0.008,0.0071,2456.28,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-04",10,9.05,259.39,,0.001,0.001,166.128,0.0593,0.01,0.0073,2795.441,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-05",11,10.42,268.28,,0.001,0.001,176.054,0.0593,0.01,0.0072,2963.076,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-06",13,9.54,305.43,,0.001,0.001,189.377,0.0595,0.011,0.0128,3184.567,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-07",7,4.66,128.51,,0,0.001,82.575,0.0594,0.007,0.0094,1388.779,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-08",12,9.05,245.17,,0.001,0.001,159.963,0.0592,0.008,0.0058,2692.675,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-09",17,13.54,479.1,,0.001,0.001,293.274,0.0593,0.015,0.006,4934.384,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-10",15,12.83,422.29,,0.001,0.001,261.459,0.0592,0.014,0.0107,4399.906,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-11",18,17.03,535.68,,0.002,0.001,337.956,0.0595,0.018,0.0066,5684.509,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-12",12,10.91,272.82,,0.001,0.001,181.414,0.0591,0.01,0.02,3051.699,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-13",18,15.83,514.9,,0.002,0.001,318.762,0.0591,0.016,0.0097,5365.354,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-14",7,4.75,113.43,,0,0.001,76.468,0.0594,0.004,0.0066,1284.779,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-15",6,4.92,208.36,,0.001,0.001,123.545,0.0592,0.008,0.0087,2078.59,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-16",10,7.74,298.3,,0.001,0.001,180.844,0.0591,0.011,0.0179,3041.734,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-17",14,11.27,378.31,,0.001,0.001,233.859,0.0591,0.014,0.0093,3934.866,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-18",17,15.29,375.44,,0.001,0.001,248.054,0.0594,0.015,0.0072,4172.516,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-19",11,7.65,180.96,,0.001,0.001,120.644,0.0593,0.008,0.0087,2030.444,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-20",18,13.67,334.04,,0.001,0.001,223.458,0.0593,0.014,0.0101,3759.56,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-21",15,12.65,320.48,,0.001,0.001,207.974,0.0594,0.013,0.0086,3497.441,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-22",20,15.92,389.81,,0.001,0.001,260.738,0.0595,0.016,0.0082,4386.194,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-23",15,11.72,300.5,,0.001,0.001,198.862,0.0593,0.012,0.0104,3347.3,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-24",18,14.78,363.36,,0.001,0.001,241.681,0.0592,0.016,0.0099,4070.67,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-25",17,13.8,340.28,,0.001,0.001,226.015,0.0592,0.015,0.0111,3806.505,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-26",17,15.4,383.48,,0.001,0.001,254.776,0.0592,0.016,0.0098,4288.144,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-27",22,18.39,459.93,,0.002,0.001,308.251,0.0595,0.017,0.0069,5182.693,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-28",18,14.71,363,,0.001,0.001,242.064,0.0595,0.013,0.0064,4070.692,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-29",21,19.75,505.15,,0.002,0.001,328.83,0.0593,0.016,0.0059,5531.765,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-30",22,19.6,533.04,,0.002,0.001,344.209,0.0592,0.014,0.005,5790.567,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-07-31",21,19.03,565.61,,0.002,0.001,356.207,0.0594,0.014,0.0048,5992.819,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-01",5,3.43,84.79,,0,0.001,56.165,0.0592,0.003,0.0092,945.737,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-03",9,7.76,193.32,,0.001,0.001,129.18,0.0594,0.007,0.0072,2172.988,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-04",4,2.47,59.34,,0,0.001,39.927,0.0593,0.003,0.0108,671.948,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-07",2,0.68,13.64,,0,0.001,9.773,0.059,0.001,0.016,164.581,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-10",3,1.18,27.26,,0,0.001,18.198,0.0593,0.001,0.024,306.554,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-11",7,3.77,101.32,,0,0.001,65.188,0.0591,0.004,0.0114,1096.785,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-12",3,2.2,66.69,,0,0.001,42.379,0.06,0.003,0.0073,711.446,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-13",8,6.94,186.86,,0.001,0.001,121.54,0.0594,0.007,0.0071,2045.032,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-14",10,8.97,253.18,,0.001,0.001,161.683,0.0595,0.008,0.0061,2717.718,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-15",9,5.82,153.96,,0.001,0.001,99.922,0.0597,0.005,0.0131,1679.336,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-16",7,3.89,94.7,,0,0.001,62.461,0.0596,0.004,0.0221,1050.992,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-17",9,7.72,196.76,,0.001,0.001,127.092,0.0592,0.006,0.006,2141.024,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-18",12,9.45,275.57,,0.001,0.001,173.726,0.059,0.008,0.0085,2925.816,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-19",6,4.68,118.22,,0,0.001,76.214,0.059,0.004,0.0075,1283.076,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-20",4,2.95,72.28,,0,0.001,47.236,0.059,0.003,0.007,796.393,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-21",10,7.55,267.36,,0.001,0.001,164.39,0.0593,0.007,0.0089,2767.143,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-23",3,1.18,28,,0,0.001,18.924,0.0597,0.002,0.045,318.638,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-24",4,2.7,66.28,,0,0.001,43.074,0.059,0.003,0.0098,725.138,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-25",4,2.95,73.16,,0,0.001,48.136,0.0595,0.002,0.0045,808.963,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-26",4,2.2,53.32,,0,0.001,34.852,0.0593,0.002,0.0308,586.552,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-27",14,12.22,343.96,,0.001,0.001,218.976,0.0594,0.009,0.0094,3685.084,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-28",14,11.62,326.22,,0.001,0.001,208.57,0.0592,0.007,0.0126,3506.23,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-08-31",7,5.19,129.16,,0,0.001,85.235,0.059,0.005,0.0219,1434.132,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-01",11,9.23,235.85,,0.001,0.001,154.362,0.0594,0.007,0.0093,2598.866,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-03",8,4.95,172.01,,0.001,0.001,106.426,0.0593,0.006,0.0181,1792.426,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-04",7,5.72,191.56,,0.001,0.001,118.748,0.0593,0.006,0.0067,1997.504,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-05",7,6.4,206.2,,0.001,0.001,129.24,0.0591,0.007,0.0071,2175.74,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-06",8,7.1,209,,0.001,0.001,133.34,0.0593,0.009,0.022,2244.18,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-07",8,7.27,186.32,,0.001,0.001,122.475,0.0594,0.007,0.0076,2061.965,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-08",7,5.65,143.68,,0,0.001,93.222,0.0593,0.004,0.007,1568.016,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-11",4,3.67,92.05,,0,0.001,60.144,0.059,0.003,0.007,1013.371,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-14",4,2.19,53.2,,0,0.001,35.249,0.0595,0.002,0.0203,591.879,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-15",3,2.11,60.44,,0,0.001,38.478,0.0593,0.002,0.007,647.727,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-16",5,3.2,79.32,,0,0.001,52.424,0.0598,0.003,0.02,880.408,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-17",6,4.29,107.42,,0,0.001,70.67,0.0593,0.004,0.0162,1189.459,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-18",4,2.57,69.83,,0,0.001,44.709,0.059,0.003,0.0185,752.607,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-22",7,6.28,277.98,,0.001,0.001,164.514,0.0593,0.011,0.0081,2767.124,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-23",4,2.54,62.02,,0,0.001,40.702,0.0598,0.003,0.0125,683.482,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-25",3,1.2,24.68,,0,0.001,17.764,0.0593,0.002,0.0343,298.724,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-26",2,1.3,33.98,,0,0.001,22.409,0.0595,0.001,0.0065,377.313,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-28",4,2.79,68.44,,0,0.001,44.936,0.0598,0.002,0.0053,754.728,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-29",3,1.55,40.08,,0,0.001,26.026,0.059,0.002,0.0197,438.497,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-09-30",2,0.82,14.16,,0,0.001,10.934,0.0595,0.001,0.0685,184.33,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-01",4,2.29,55.54,,0,0.001,36.16,0.0595,0.002,0.0108,608.026,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-02",8,5.83,145.15,,0,0.001,95.743,0.0593,0.006,0.0084,1609.463,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-03",7,4.38,108.34,,0,0.001,71.229,0.0594,0.004,0.012,1198.145,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-04",3,1.27,28.5,,0,0.001,19.697,0.0593,0.002,0.0217,331.449,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-05",7,4.71,124.31,,0,0.001,80.475,0.0591,0.004,0.0101,1355.228,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-06",9,7.15,179.87,,0.001,0.001,117.581,0.0593,0.005,0.0058,1977.261,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-07",6,2.66,61.42,,0,0.001,41.33,0.0593,0.002,0.0192,695.446,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-08",2,1.08,32.88,,0,0.001,21.096,0.059,0.002,0.01,355.2,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-09",2,0.45,11.34,,0,0.001,7.677,0.0595,0.001,0.0515,129.3,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-12",7,5.02,145.82,,0,0.001,92.002,0.0594,0.005,0.0084,1546.848,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-13",5,4.04,110.11,,0,0.001,70.992,0.0598,0.004,0.008,1192.738,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-14",11,9,278.53,,0.001,0.001,175.484,0.0593,0.009,0.0074,2953.337,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-15",13,9.95,249.79,,0.001,0.001,163.987,0.0592,0.007,0.0082,2762.117,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-16",8,7.05,178.68,,0.001,0.001,116.096,0.0593,0.005,0.0054,1952.696,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-17",5,4.05,100.8,,0,0.001,65.937,0.0592,0.003,0.0058,1111.543,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-18",4,3.05,74.67,,0,0.001,49.145,0.059,0.002,0.0063,827.228,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-19",4,1.75,38.33,,0,0.001,26.18,0.0598,0.003,0.021,439.72,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-20",4,3.04,74.56,,0,0.001,49.076,0.0593,0.002,0.006,825.464,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-21",4,2.79,70.11,,0,0.001,46.056,0.0593,0.002,0.0143,775.394,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-22",6,3.62,91.12,,0,0.001,60.715,0.0592,0.004,0.0073,1021.566,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-23",5,3.29,81.42,,0,0.001,53.465,0.0592,0.003,0.0128,899.349,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-24",2,0.5,10.14,,0,0.001,7.313,0.059,0.001,0.0135,123.206,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-25",3,1.7,40.8,,0,0.001,26.96,0.059,0.002,0.0197,454.24,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-26",8,5.74,140.94,,0,0.001,93.119,0.0593,0.005,0.0106,1567.485,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-27",7,5.54,165.6,,0.001,0.001,106.386,0.059,0.006,0.0073,1791.086,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-28",6,3.56,78.71,,0,0.001,54.574,0.0597,0.004,0.0102,917.933,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-29",5,3.68,91.39,,0,0.001,59.839,0.0592,0.003,0.0076,1007.459,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-30",4,2.21,53.16,,0,0.001,35.285,0.059,0.002,0.024,594.448,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-10-31",3,2.03,46.87,,0,0.001,31.51,0.0597,0.003,0.011,530.204,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-01",4,2.9,71.32,,0,0.001,46.526,0.059,0.003,0.0075,782.76,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-02",8,5.9,143.98,,0,0.001,94.394,0.0594,0.005,0.0066,1588.277,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-03",11,6.76,162.88,,0.001,0.001,107.089,0.0592,0.005,0.0117,1804.212,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-04",3,1.68,39.39,,0,0.001,26.233,0.0593,0.003,0.019,441.854,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-10",2,0.3,3.9,,0,0.001,3.342,0.059,0.001,0.027,56.352,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-11",3,1.52,40.35,,0,0.001,26.801,0.0593,0.002,0.008,450.6,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-13",4,2.43,58.6,,0,0.0008,38.044,0.0593,0.003,0.0185,639.521,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-16",5,3.67,91.83,,0,0.001,58.762,0.059,0.003,0.0076,989.437,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-18",9,7.04,114.5,,0,0.001,89.032,0.0591,0.005,0.0102,1499.85,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-19",4,3.34,156.44,,0,0.001,90.37,0.059,0.004,0.0058,1521.656,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-20",7,6.42,162.78,,0.001,0.001,102.514,0.0591,0.006,0.0079,1727.407,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-21",7,6.38,161.53,,0.001,0.001,101.686,0.0593,0.005,0.0059,1711.309,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-22",3,1.29,29.76,,0,0.001,19.409,0.059,0.001,0.014,326.793,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-24",2,1.3,29.2,,0,0.001,20.01,0.0595,0.001,0.008,336.23,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-29",2,1.27,28.81,,0,0.001,18.93,0.059,0.002,0.0125,318.976,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-02",4,1.68,51.85,,0,0.0008,32.268,0.0593,0.003,0.0143,543.294,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-03",10,6.43,155.78,,0.001,0.001,102.259,0.0594,0.008,0.0144,1720.144,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-07",9,7.49,296.4,,0.001,0.001,172.584,0.0592,0.012,0.011,2904.109,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-14",2,1.67,38.74,,0,0.001,25.282,0.059,0.004,0.018,426.421,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-27",2,1.25,27.9,,0,0.001,18.784,0.0595,0.001,0.0075,315.704,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D1",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 20, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-04-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-05-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-03",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-07",2,0.96,20.24,,0,0.001,14.048,0.059,0.004,0.0185,237.016,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-08",2,0.85,13.65,,0,0.001,10.442,0.059,0.001,0.011,176.116,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-09",1,0.45,7.65,,0,0.001,5.805,0.06,0.001,0.015,97.56,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-10",10,9.12,79.24,,0,0.001,83.052,0.0592,0.005,0.0073,1399.676,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-11",10,9.44,297.96,,0.001,0.001,187.448,0.0592,0.014,0.0094,3153.606,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-17",4,2.43,89.43,,0,0.001,54.184,0.0593,0.004,0.0095,911.563,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-28",3,1.8,49.98,,0,0.001,32.042,0.0597,0.003,0.019,539.534,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-29",3,1.7,24.26,,0,0.001,19.838,0.06,0.002,0.0093,333.084,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-06-30",3,1.01,30.52,,0,0.001,19.645,0.0597,0.002,0.008,330.324,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-01",8,5.32,139.53,,0,0.001,90.676,0.0593,0.006,0.0101,1526.547,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-02",8,6.53,171.32,,0.001,0.001,111.167,0.0595,0.007,0.0075,1870.457,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-03",9,7.57,236.32,,0.001,0.001,148.255,0.0593,0.008,0.0074,2493.691,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-04",10,8.7,280.46,,0.001,0.001,175.004,0.0592,0.011,0.0094,2944.984,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-05",11,10.42,271.88,,0.001,0.001,177.28,0.0595,0.011,0.0077,2982.19,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-06",12,8.62,358.43,,0.001,0.001,212.746,0.0594,0.014,0.0214,3579.301,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-07",9,6.33,188.6,,0.001,0.001,118.985,0.0591,0.007,0.0067,2003.635,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-08",13,9.98,269.06,,0.001,0.001,173.812,0.0592,0.01,0.0066,2926.068,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-09",8,4.56,107.9,,0,0.001,71.91,0.0593,0.004,0.0128,1211.172,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-10",13,10.78,412.1,,0.001,0.001,248.324,0.0592,0.016,0.0137,4176.881,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-11",20,17.73,563.88,,0.002,0.001,351.856,0.0593,0.02,0.009,5921.374,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-12",19,16.57,435.21,,0.001,0.001,283.476,0.0594,0.016,0.0067,4770.397,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-13",21,19.71,621.23,,0.002,0.001,386.154,0.0592,0.017,0.0054,6501.047,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-14",14,11.49,385.33,,0.001,0.001,238.81,0.0593,0.014,0.0071,4018.163,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-15",6,5.05,215.75,,0.001,0.001,126.965,0.059,0.008,0.0087,2137.01,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-16",10,7.72,302.24,,0.001,0.001,181.68,0.0592,0.011,0.0164,3057.595,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-17",14,11.29,385.64,,0.001,0.001,236.281,0.0593,0.014,0.0119,3974.627,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-18",16,14.51,362.1,,0.001,0.001,238.32,0.0591,0.014,0.0069,4014.702,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-19",11,7.69,183.89,,0.001,0.001,122.626,0.0594,0.005,0.0061,2063.121,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-20",18,13.65,345.47,,0.001,0.001,226.589,0.0594,0.015,0.0097,3813.221,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-21",10,6.24,153.62,,0.001,0.001,101.302,0.0594,0.007,0.0131,1705.517,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-22",20,15.93,412.48,,0.001,0.001,269.271,0.0594,0.017,0.0077,4529.259,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-23",15,11.71,296.57,,0.001,0.001,193.905,0.0593,0.012,0.0084,3264.515,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-24",18,15.51,395.69,,0.001,0.001,258.585,0.0593,0.017,0.0122,4351.384,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-25",17,13.81,351.41,,0.001,0.001,229.892,0.0593,0.015,0.0104,3867.958,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-26",17,15.4,396.48,,0.001,0.001,259.156,0.0596,0.017,0.0099,4356.324,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-27",22,18.35,473.92,,0.002,0.001,311.726,0.0593,0.019,0.0071,5246.671,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-28",20,17.55,448.71,,0.001,0.001,294.629,0.0595,0.017,0.007,4952.326,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-29",18,16.28,419.43,,0.001,0.001,273.963,0.0594,0.017,0.0096,4608.153,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-30",22,20.47,577.68,,0.002,0.001,368.891,0.0593,0.021,0.0067,6205.341,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-07-31",21,19.05,571.05,,0.002,0.001,359.931,0.0596,0.021,0.007,6050.826,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-01",5,3.47,85.94,,0,0.001,57.241,0.0592,0.004,0.011,963.511,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-03",9,7.76,198.32,,0.001,0.001,131.148,0.0593,0.009,0.0083,2207.744,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-04",4,2.49,60.5,,0,0.001,40.642,0.059,0.003,0.0113,684.168,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-07",2,0.68,14.32,,0,0.001,9.977,0.059,0.002,0.019,167.942,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-10",3,1.2,27.24,,0,0.001,18.6,0.0593,0.002,0.0313,313.396,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-11",4,2.67,65.56,,0,0.001,43.566,0.0593,0.004,0.0105,733.666,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-12",3,2.2,67.89,,0,0.001,43.185,0.059,0.004,0.0093,727.436,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-13",9,5.99,145.04,,0,0.001,96.696,0.0592,0.007,0.0084,1627.046,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-14",10,9.05,256.61,,0.001,0.001,165.427,0.0594,0.009,0.0069,2781.561,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-15",5,3.2,89.6,,0,0.001,57.85,0.0594,0.004,0.0278,973.32,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-16",13,12.12,313.48,,0.001,0.001,204.964,0.0595,0.011,0.0064,3447.82,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-17",11,8.84,239.24,,0.001,0.001,154.264,0.0593,0.008,0.0061,2598.812,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-18",12,10.86,317.6,,0.001,0.001,202.124,0.0593,0.01,0.0058,3401.393,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-19",5,3.7,92.98,,0,0.001,61.282,0.059,0.003,0.0074,1031.994,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-20",4,2.95,73.11,,0,0.001,48.392,0.0593,0.004,0.0085,815.404,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-21",5,3.2,78.12,,0,0.001,51.92,0.0596,0.003,0.0232,873.224,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-22",3,2.1,54.1,,0,0.001,35.34,0.0593,0.003,0.009,594.53,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-24",13,9.44,272.04,,0.001,0.001,174.156,0.0592,0.009,0.0157,2930.1,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-25",13,11.62,301.36,,0.001,0.001,197.218,0.0593,0.01,0.0068,3318.112,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-26",10,6.4,159.36,,0.001,0.001,105.148,0.0593,0.006,0.0225,1767.896,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-27",12,8.42,222.86,,0.001,0.001,145.46,0.0594,0.009,0.018,2447.544,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-28",12,9.21,253.48,,0.001,0.001,164.198,0.0595,0.01,0.0164,2761.617,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-08-31",5,4.12,103.48,,0,0.001,68.164,0.0594,0.005,0.0084,1146.972,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-01",6,4.75,119.07,,0,0.001,79.176,0.0592,0.006,0.0165,1331.962,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-03",9,5.25,173.89,,0.001,0.001,109.569,0.0593,0.008,0.0183,1843.095,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-04",7,5.72,191.56,,0.001,0.001,120.564,0.0593,0.008,0.0086,2030.672,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-05",7,6.4,235.4,,0.001,0.001,144.36,0.0593,0.01,0.0084,2429.14,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-06",8,5.03,91.63,,0,0.001,67.322,0.0594,0.006,0.0339,1131.981,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-07",8,7.27,186.32,,0.001,0.001,121.475,0.0593,0.006,0.0061,2042.981,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-08",7,5.65,143.68,,0,0.001,92.922,0.0594,0.007,0.0093,1563.018,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-09",3,1.37,28.69,,0,0.001,20.238,0.059,0.002,0.0453,340.548,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-10",2,0.74,18.48,,0,0.001,12.252,0.0595,0.001,0.0125,206.29,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-11",6,4.8,98.46,,0,0.001,67.795,0.0598,0.005,0.008,1138.865,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-12",2,1.4,24.2,,0,0.001,18.46,0.0595,0.001,0.0075,310.604,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-14",8,5.47,132.9,,0,0.001,87.06,0.0594,0.006,0.0133,1465.756,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-15",5,2.95,69.74,,0,0.001,46.682,0.0594,0.004,0.0092,785.044,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-16",5,3.2,79.24,,0,0.001,51.308,0.0596,0.004,0.0298,864.076,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-17",6,4.12,113.79,,0,0.001,72.768,0.0597,0.008,0.0162,1222.467,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-18",6,3.84,104.04,,0,0.001,66.837,0.0595,0.005,0.011,1123.972,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-19",10,8.29,212.02,,0.001,0.001,136.315,0.0593,0.008,0.0082,2292.783,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-20",1,0.37,7.03,,0,0.001,5.069,0.059,0,0.006,85.581,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-23",12,9.42,343.42,,0.001,0.001,209.698,0.0593,0.014,0.0093,3529.426,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-24",11,9.6,255.64,,0.001,0.001,165.756,0.0591,0.011,0.0075,2791.024,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-28",4,2.79,68.56,,0,0.001,45.706,0.0595,0.004,0.0098,768.095,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-29",5,3.79,102.31,,0,0.001,66.297,0.0592,0.005,0.018,1115.566,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-09-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-01",12,11,296.56,,0.001,0.001,192.988,0.0595,0.014,0.0082,3245.028,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-02",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-03",3,1.8,42.56,,0,0.001,28.288,0.0597,0.003,0.011,475.58,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-04",3,1.28,29.44,,0,0.001,19.886,0.059,0.002,0.029,334.496,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-05",5,3.29,81.54,,0,0.001,53.925,0.059,0.004,0.0194,907.979,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-06",5,4.04,101.72,,0,0.001,67.248,0.0594,0.004,0.007,1130.388,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-07",4,2.79,68.44,,0,0.001,45.782,0.0593,0.003,0.0078,770.11,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-08",3,1.22,43.08,,0,0.001,26.364,0.0597,0.004,0.0133,443.02,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-09",8,7.52,196.92,,0.001,0.001,127.84,0.0595,0.006,0.0058,2150.284,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-12",5,3.29,92.54,,0,0.001,58.984,0.0592,0.005,0.0218,992.357,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-13",5,4.04,111.11,,0,0.001,72.367,0.0592,0.006,0.0124,1217.996,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-14",13,10.98,322.32,,0.001,0.001,205.824,0.0592,0.012,0.0109,3464.41,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-15",8,5.38,141.78,,0,0.001,92.42,0.0594,0.006,0.0085,1555.431,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-16",10,7.34,182.76,,0.001,0.001,121.708,0.0595,0.007,0.0151,2046.148,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-17",5,4.05,101.73,,0,0.001,67.335,0.0594,0.004,0.0076,1132.691,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-18",4,3.05,75.35,,0,0.001,50.06,0.059,0.005,0.0125,843.068,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-19",2,0.43,3.58,,0,0.001,3.786,0.0595,0.004,0.1005,63.539,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-20",6,4.37,103.79,,0,0.001,69.724,0.0597,0.004,0.0085,1171.611,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-21",10,6.98,175.69,,0.001,0.001,115.911,0.0595,0.008,0.0159,1949.116,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-22",10,8.31,213.79,,0.001,0.001,139.9,0.0594,0.007,0.0066,2354.848,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-23",4,1.82,41.21,,0,0.001,28.428,0.0595,0.003,0.0228,478.682,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-24",3,1.75,42.4,,0,0.001,28.19,0.0593,0.003,0.0433,473.915,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-25",3,1.69,40.13,,0,0.001,26.881,0.059,0.002,0.0427,452.467,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-26",8,5.67,140.02,,0,0.001,93.231,0.0595,0.006,0.0165,1568.258,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-27",7,4.42,142.11,,0,0.001,89.55,0.0593,0.005,0.0206,1508.421,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-28",4,2.3,52.2,,0,0.001,35.495,0.0595,0.004,0.0135,597.885,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-29",4,2.4,58.45,,0,0.001,38.955,0.0598,0.003,0.0133,654.265,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-30",6,3.39,81.48,,0,0.001,54.807,0.0595,0.004,0.0195,922.663,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-10-31",3,2.03,47.25,,0,0.001,32.016,0.0593,0.004,0.0137,538.81,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-01",3,1.93,46.55,,0,0.001,30.811,0.0597,0.003,0.0103,517.766,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-02",7,5.7,144.59,,0,0.001,94.174,0.0593,0.006,0.0089,1586.306,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-03",4,2.67,63.92,,0,0.001,42.564,0.059,0.004,0.0095,716.456,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-04",3,1.18,27.35,,0,0.001,18.23,0.0593,0.001,0.0097,306.656,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-08",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-09",2,0.62,15.08,,0,0.001,10.16,0.06,0.003,0.068,170.51,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-10",3,1.97,62.95,,0,0.001,39.581,0.059,0.003,0.0097,666.52,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-11",7,3.07,68.3,,0,0.0009,47.123,0.059,0.004,0.0151,793.851,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-13",4,2.43,59,,0,0.0008,38.758,0.059,0.003,0.0215,652.417,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-14",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-16",5,3.68,92.07,,0,0.001,60.048,0.0594,0.004,0.0094,1010.064,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-17",2,1.18,26.49,,0,0.001,17.835,0.0595,0.002,0.012,300.329,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-19",9,8.05,183,,0.001,0.0009,126.745,0.0593,0.007,0.0163,2131.29,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-20",7,6.43,163.02,,0.001,0.001,105.009,0.0591,0.007,0.0084,1766.952,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-21",7,6.38,162.91,,0.001,0.001,104,0.0594,0.007,0.008,1747.938,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-22",3,1.29,29.59,,0,0.001,19.799,0.0593,0.002,0.0167,332.389,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-27",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-29",2,1.27,29.21,,0,0.001,19.358,0.0595,0.002,0.014,325.596,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-11-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-01",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-02",7,3.54,94.51,,0,0.0009,61.267,0.0594,0.004,0.0123,1030.226,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-03",10,6.47,173.14,,0.001,0.0009,111.27,0.0593,0.007,0.0117,1871.807,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-04",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-05",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-06",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-07",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-08",8,7.13,275.6,,0.001,0.001,163.892,0.0594,0.013,0.0094,2757.163,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-09",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-10",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-11",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-12",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-13",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-14",2,1.67,40.41,,0,0.001,25.783,0.0595,0.003,0.0135,433.638,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-15",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-16",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-17",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-18",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-19",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-20",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-21",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-22",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-23",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-24",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-25",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-26",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-27",2,1.25,29.15,,0,0.001,19.159,0.06,0.002,0.009,321.581,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-28",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-29",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-30",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP" "CA","Stanton Energy Reliability Center",60698,"D7",,"2020-12-31",0,0,,,,,,,,,,"Pipeline Natural Gas",,"Combustion turbine (Started Apr 17, 2020)",,"Water Injection,Selective Catalytic Reduction",,,"ARP"